TS Fault sync in Ericsson - Wire Free Alliance

Dear Friends,
What is the reason of alarm "TS Fault sync" in ericsson systems .How we can rectify
it. in my case it happened for some site after EDGE TS increasing (NUMREQBPC)
Let me know how we can rectify it
Thanks ,

5 Lastest Threads by electron


Thread

Forum

Ericsson RNC Dump

Ericsson

2G/3G Actix celref

ACTIX

Last Poster

Replies

Views

Darko

50

2010-1127 11:09
PM

43

2010-1126 08:18
AM

sonerss

Last Post

Ericsson

electron

30

2010-1125 03:45
PM

ACLC Parameter

Ericsson

electron

29

2010-1122 04:49
PM

FBCHALLOC

Ericsson

electron

38

2010-1122 04:44
PM

SDCCH Usage distribution


counter

2010-08-19, 02:26 PM

kvf
Senior Member

http://www.finetopix.com/ericsson/11815-ts-fault-sync-ericsson.html (1 of 5)29.11.2010 11:59:55

#2

Join Date: 2007-09-19


Posts: 343
Rep Power: 5
Reputation:188
Credit: 619

TS Fault sync in Ericsson - Wire Free Alliance

Default

Re: TS Fault sync in Ericsson

TS SYNC FAULT - Synchronization lost on uplink / downlink TRAU or PCU channels


Feature: Traffic decreasing, Drop and Block call increasing
Influence on: SDCCH performance, TCH performance, EDGE\GPRS performance.
The sources of TS SYNC FAULT are different and must be checked specifically for each
site: Inconsistency connected and defined RBS ports;Incorrect RBS mode (CASCADED
or STAND ALONE); Transmission or RBS disconnection during works or failure; Bad
transmission quality; Poor RBS E1 cables or connectors, etc
in common case use commands rxbli/rxble - This commands orders the manual
blocking/unblocking of one or more MO instances (TS for us)
(for example RXBLI:MO=RXOTS-215-2-0&&7;!block, RXBLE - unblocking! )
Quote:

Originally Posted by electron


Dear Friends,
What is the reason of alarm "TS Fault sync" in ericsson systems .How we can
rectify it. in my case it happened for some site after EDGE TS increasing
(NUMREQBPC)
Let me know how we can rectify it
Thanks ,

Last edited by kvf; 2010-08-19 at 06:26 PM

The Following User Says Thank You to kvf For This Useful Post:
electron
2010-08-19, 06:18 PM

http://www.finetopix.com/ericsson/11815-ts-fault-sync-ericsson.html (2 of 5)29.11.2010 11:59:55

#3

TS Fault sync in Ericsson - Wire Free Alliance

electron
Senior Member

Default

Join Date: 2009-05-02


Posts: 281
Rep Power: 2
Reputation:135
Credit: 3987

Re: TS Fault sync in Ericsson

Thanks for replay,


But it happened after increasing NUMREQEGPRS for some cells suddenly.Is there any
correlation?

Thanks

2010-08-19, 09:59 PM

andr2008
Junior Member

Default

#4

Join Date: 2009-01-09


Posts: 14
Rep Power: 2
Reputation:10
Credit: 44

Re: TS Fault sync in Ericsson

Hello!
It can be from the confactor is big, it means that not enough space for signalling
channels in the E1. I recommend to increase quantity E1 and reduce confactor.
BR

2010-08-20, 04:38 AM

http://www.finetopix.com/ericsson/11815-ts-fault-sync-ericsson.html (3 of 5)29.11.2010 11:59:55

#5

TS Fault sync in Ericsson - Wire Free Alliance

redernesto
Member

Default

Join Date: 2009-03-21


Posts: 44
Rep Power: 2
Reputation:50
Credit: 123

Re: TS Fault sync in Ericsson

Hi
This problem show, when 1 TS is no consecutive count, one TS in the , recomendation
erase configuration for RXAPE and do you create new TS structure with RXAPI.

2010-08-20, 06:28 AM

radenmohawk
Member

Default

#6

Join Date: 2009-03-24


Posts: 153
Rep Power: 2
Reputation:36
Credit: 668

Re: TS Fault sync in Ericsson

Quote:

Originally Posted by redernesto


Hi
This problem show, when 1 TS is no consecutive count, one TS in the ,
recomendation erase configuration for RXAPE and do you create new TS
structure with RXAPI.
which time slot have to erase? how to find the problem time slot?

2010-08-20, 06:58 AM

http://www.finetopix.com/ericsson/11815-ts-fault-sync-ericsson.html (4 of 5)29.11.2010 11:59:55

#7

TS Fault sync in Ericsson - Wire Free Alliance

roloramos
Member

Default

Join Date: 2010-05-13


Posts: 75
Rep Power: 1
Reputation:36
Credit: 893

Re: TS Fault sync in Ericsson

rxbli:mo=rxots-xx-yy;
rxese:mo=rxots-xx-yy;
rxesi:mo=rxots-xx-yy;
rxlti:mo=rxots-xx-yy;
rxble:mo=rxots-xx-yy;

The Following 2 Users Say Thank You to roloramos For This Useful Post:
electron, kamnikot
2010-09-05, 01:03 AM

zee86
Member

Default

Re: TS Fault sync in Ericsson

rxbli:mo=rxots-xx-yy-zz;
rxlti:mo=rxots-xx-yy-zz;
rxble:mo=rxots-xx-yy-zz;
also check what is fault code
rxasp:mo=rxots-xx-yy-zz;
rxmfp:mo=rxots-xx-yy-zz;
fault code list is attached without pass
Comments