You are on page 1of 36

Product

Catalog
2016

Fluke Biomedical.

Trusted for the measurements that matter.

Trusted for the measurements


that matter.
Fluke Biomedical leads the world in the design and manufacture of biomedical
test and simulation products. We achieved our leadership position by being the
company customers can rely on. Reliability is the linchpin of our identity, and
our greatest asset.

What does Fluke Biomedical reliability look like?

Best-in-class service
and sales support
programs

When you invest in the best


products, you deserve the best
support. Fluke Biomedical has
several world-class service centers, including the worlds largest
commercial laboratory. These
centers are capable for servicing
over 1000 different products with
product and firmware updates,
NIST-traceable calibration, and
90-day warranty repairs.
Additionally, the global Fluke
Biomedical customer service
teams are on-call to handle all
your product specification, pricing
and delivery questions. Our teams
work closely with our field sales
representatives to ensure the
needs of each individual customer
are addressed.

Unbeatable product
qualityrugged,
accurate and safe

Fluke Biomedicals benchmark


quality operates to the most
rigorous standards in the
industry, including compliance
with ISO 9001:2000, ISO
13485:2003, QSR and NRC/
Part 50, Appendix B/Part 21 and
adheres to ISO 17025:2005, ANSI
Z540, Mammography MQSA and
CNSC. Many of the products are
CE-marked and CSA-certified.
In addition, the Global Calibration
Laboratory holds its NVLAP
Lab Code 200566-0 certification and is traceable to
both the NIST and PTB.

Globally available
product and
application training

Fluke Biomedical is proud to


offer no-cost training on medical
device performance and safety
testing, documenting for regulatory compliance, productivity
improvement and effective
use of test instruments. Our
training center is organized
into medical device testing categories, and includes webinars,
training modules, instructional videos and app notes.

About Fluke
Corporation
Fluke Biomedical is a division
of Fluke Corporation. Fluke
Corporation is the world leader
in the manufacture, distribution
and service of electronic test tools
and software, and is a wholly
owned subsidiary of Danaher
Corporation (NYSE:DHR).

Introduction

Featured Products Catalog


Contents

Biomedical Test and Measurement

Automation
Solutions

Defibrillator/
Transcutaneous
Pacer Analyzers

Electrosurgery
Analyzer

Infusion
Device
Analyzers

10

15

20

23

Electrical
Safety
Analyzers

Patient
Simulators

Gas Flow
Analyzers

Neonatal
Test Equipment

25
Digital
Pressure Meters

Imaging and Therapy Quality Assurance

26
Medical
Oscilloscope

Radiation Safety

27
Ion Chamber
Survey Meters

Service, Calibration and misc.

CarePlans.........................................................................32
Service information....................................................... 33
Calibration information................................................ 33
Ordering information.................................................... 34

For a complete listing of Fluke Biomedical products and services, please


visit our website at www.flukebiomedical.com.
Table of contents

Ansur

Test Automation Software


Key features

How well do your PM inspection and post-repair performance testing processes


eliminate sources of human error?
Wish that all technicians would document results the same way?
Do you have enough time to complete all PM inspection and repair work on
your shelf?

Ansur offers a solution:

RepeatabilityCreates standard work so everyone tests the same way every


time.
QualityCan automatically configure and collect data from the compatible test
devices to minimize human error and save time.
ProductivityEnsure that the amount of time required to perform testing is
uniform and therefore, predictable by using ready-to-use and customizable
test templates. The Ansur test automation system collects all the observe-andrecord manual entries as well as automated measurements from compatible
simulators and performance analyzers from Fluke Biomedical.

Automate with Ansur

Look for this logo in the Fluke Biomedical product catalog to


see where test automation can benefit you.

Allows for creation and


management of custom
electronic test protocols to
eliminate dependence on
service manuals
Guides users through stepwise
testing process to ensure
standardized testing
Generates test report (PDF or
MTR) per requirements with
needed level of data to ensure
compliance
Enables the use of personalized
pictures, illustrations and
graphs to facilitate proper
testing with ease
Automatically assesses pass/
fail against test limits specified
by global standards or
organizations
21CFR Part 11 compliant. Users
can create their own signature
and sign templates and results.
(This feature can be disabled)
Authorization levels can be
assigned to manage level of
access to software. Levels
include User, Author and
Administrator (This feature can
be disabled)
Reduces test time per medical
device, tests multiple devices
simultaneously, and performs
multiple PM tests in a single
procedure
Offers easy data traceability
with electronic archival and
printing of detailed records
Data extraction offers trending,
analysis and reporting
capability

Specifications
PC hardware
requirements

Intel Pentium 4 2.0 GHz FSB @400 MHz or faster processor


512 MB of RAM Microsoft operating system: Windows 2000,
Windows XP, Windows Vista, Windows 7 or Windows 8
50 MB of available hard drive for software Hard drive space
(from 100 k to several megabytes) for result and template files
Net framework version 2.0 or newer

PC software
requirements
with electronic
signature

This software is required on the central PC (for a network configuration) or each PC (for a nonnetworked configuration):

Other requirements

License key for each Fluke Biomedical simulator/ analyzer plug-in

Microsoft SQL Server 2005


Express Ansur Executive Server
One or more Ansur-compatible Fluke Biomedical simulators or
analyzers

For full specifications please visit www.flukebiomedical.com/ANSUR


4

Automation Solutions

We used Ansur to create


test sequences that match
service manual procedures
so every inspection is done
the same way every time.
We improved quality and
uniformity by creating
standard work.
-Robert Dorrian,
TBS U.K. Telematic & Biomedical
Services Ltd. Hope Hospital

Impulse 7000DP

Defibrillator Tester/External Pacemaker Analyzer


Key features

Instrument CarePlans

Si

er

ze

Biomedical Products

lv

Br o

The Impulse 7000DP is a combination Defibrillator/Transcutaneous Pacemaker


Analyzer that is portable, rugged, and easy-to-carry. It delivers any energy
or waveform, properly tests all defibrillator and AED devices (including Shock
Advisory), ensures proper loads used for testing, and delivers superior performance with accuracy measurements 1 % of reading +.01 J.
Impulse 7010 Selectable Load Accessory
The 7010 Selectable Load Box
replicates selectable impedance
values and simulates user-selectable
impedances as high as 200 ohms
accurately, ensuring IEC 60601-2-4
compliance. The 7010 Load Box and
Impulse 7000DP work together as a
system to replicate all possible human
variations and ensure patient safety.

Specifications
Safety standards

CE: IEC/EN61010-1 2nd Edition; Pollution degree 2, CAN/CSA-C22.2


No 61010-1; UL61010-1, C-Tick: Australian EMC

Autoranged
measurement

0.1 J to 600 J

Accuracy

0.1 J to 360 J: 1 % of reading +0.1 J


360 J to 600 J: 1 % of reading +0.1 J, typical
Note: For pulsed bi-phasic defibrillator, specified accuracy is
(1.5 % of reading + 0.3 J) on both ranges

Resistance: 50

Accuracy

1 %, non-inductive (< 2 H)

Charge time
measurement

Range: 0.1 s to 100 s

Synchronization test
(cardioversion)

Delay time measurement

Included
accessories
1626219 USB Computer
Communication Cable
3028681 User Manual CD
3028662 Getting-Started Guide
Battery Eliminator Country specific
2814980 Carrying Case
3156262 Defib Paddle Contact Plates

Optional accessories

Defibrillator Analyzer

Load resistance

IEC 60601-2-4 compliance


Lown, Edmark, trapezoidal,
biphasic and pulsed-biphasic
defibrillation technology
compatibility
AED compatibility
12-lead ECG simulation
Ability to test external transcutaneous pacemakers (Impulse
7000 DP only)
Internal pacer brand selections
Flexible heart-rate settings
(1 BPM step)
DSP-based measurements for
firmware and waveform upgrade
Waveform capture, store and
replay
First-in-class accuracy 1%
of reading + 0.1J
Long lasting, rechargeable
battery

3091370 Ansur Impulse


6000D/7000DP
Impulse 7010 Defibrillator Selectable
Load Accessory provides multiple
loads of 25 , 50 , 75 , 100 ,
125 , 150 , 175 , and 200 to
comply with IEC 60601-2-4 standard*
*Compatible only with Impulse
7000DP

Accuracy: 0.05 s, typical


Timing window: ECG R-wave peak to the defib pulse peak
Range: -120 ms to 380 ms; measures timing from 120 ms prior to
the R-wave peak to up to 380 ms following the R-wave peak
Automated defibrillator test ECG waves
Normal sinus: 10 BPM to 300 BPM in 1 BPM steps
Ventricular fibrilation: Coarse and fine
Monomorphic ventricular tachycardia: 120 BPM to 300 BPM in
1 BPM steps
Polymorphic ventricular tachycardia: Five types
Asystole

For full specifications please visit www.flukebiomedical.com/7000DP

Defibrillator/Transcutaneous Pacer Analyzers

Impulse 6000D

Defibrillator Analyzer
Key features

Instrument CarePlans

Si

er

ze

Biomedical Products

lv

Br o

If you dont require a pacemaker analyzer, the Impulse 6000D is your device.
It is the quintessential defibrillator analyzer featuring the exact functionality
of the 7000DP, but without pacemaker testing. It will deliver any energy or
waveform (monophasic, biphasic, pulsed-biphasic) while properly testing all
defibrillator and AED devices including Shock Advisory.

Defibrillator Analyzer

Included accessories

Comparison guide

Functions
Accuracy (Energy
measurement)
Default patient test load

1626219 USB Computer


Communication Cable
3028681 User Manual CD
3028662 Getting-Started Guide
Battery Eliminator Country specific
2814980 Carrying Case
3156262 Defib Paddle Contact Plates

Impulse 7000DP

Impulse 6000D

1%

1%

50

50

External pacer tests

Mono-, bi- and pulsed biphasic energy measurement

Non-inductive resistor
Protection of pacer
input against accidental
defibrillation
Test variable patient loads
Selectable measurement
algorithms, test loads for
external transcutaneous
pacemakers
Capable of testing ECG
Ansur Automatic Testing
Compatibility

(<2 H)

(<2 H)

No; Unable to test pacers

(with 7010 Load Box)

(10-lead)

(10-lead)

For full specifications please visit www.flukebiomedical.com/6000D

Defibrillator Analyzer

Portable, rugged, easy to carry


Intuitive user interface and
backlight, easy-to-read display
10 independent ECG outputs that
provide 12 lead combinations for
standardized clinical signals
Unique integrated posts for
secure connections
Optional Ansur test automation
software to standardize testing
procedures, capture waveforms
and test results, and print and
document test results
Two-year extended warranty
(no-cost extended warranty
available after first-year calibration at any Fluke Biomedical
authorized service center)

Optional accessories
3091370 Ansur Impulse
6000D/7000DP

QA-ES III

Electrosurgical Analyzer
Key features

Instrument CarePlans

Si

er

ze

Biomedical Products

lv

Br o

The QA-ES III is the easiest way to test all critical ESU functions and wirelessly* download results to a PC. Its user-friendly interface guides you through
tests, making it quick to collect all measurements, including vessel sealing,
contact quality monitor (CQM), high frequency (HF) leakage, and output power
distribution (single or continuous mode).

Specifications
Modes of operation

Test ESU functions with precise power, current, frequency,


crest factor, and load resistance
ranges
Connect wirelessly via Bluetooth
for easy record retrieval without interference or limitation by
cables and wires*
All hardware and software necessary to complete preventive
maintenance and troubleshooting is built in to the unit
User-friendly interface: large
buttons and LCD screen guide
the user through test sequences
Memory storage of up to 5,000
test records
Complies to global standards,
including ANSI/ AAMI and IEC

Continuous operation

Continuous measurement of power, current, peak-to-peak


voltage (closed load only), and crest factor

Single operation

Single measurement after the set delay time of the ESU


output of power, current, peak-to-peak voltage (closed load
only), and crest factor

Optional accessories

Power distribution

Tests impedance-sensing circuitry in power guarantee


functions in new-generation ESU. Applicable parameters
power, current, peak-to-peak voltage (closed load only) and
crest factorcan easily be observed during the automatic,
sequential output energy measurements.

RF leakage current

Provides connections and load configurations to measure HF


leakage from both grounded and isolated equipment

4635248 International dispersive lead


(1/4 inch phono plug)
1909216 Test probe set0.080
brass tip
4704312 Ansur Plug-in

CQM

Test the return electrode control quality monitoring using


the QA-ES internal loads

Generator output
Load Resistance

Variable: 0 , 10 , 20 , 25 to 2500 (by 25 ), 2500 to 5200 (by 100 ); Accuracy: 2.5% accuracy

Power (0 W to 9.9 W 5 % +
1W), 10 W to 500 W 5%

At 25% duty cycle (10 seconds on, 30 seconds off): 10 : 300 W, 20 to 2900 : 400 W, 3000 to 5200 :
200 W
At 10% duty cycle (5 seconds on, 45 seconds off): 10 : 300 W, 20 to 2400 : 500 W, 2425 to 2900 :
400 W, 3000 to 5200 : 200 W

Current

RMS: 0 mA to 5,500 mA; Accuracy: (2.5% of reading + 1 mA)

Voltage

Peak: 10 kV Peak to Peak; Accuracy: (10% of reading + 50 V); Crest factor: 1.4 to 16.0 Defined as the ratio of
Peak voltage to RMS voltage (Vpk /Vrms), using the larger of the 2 peaks (positive or negative)

Vessel sealing measurement

Loop current, RMS: 0 mA to 5500 mA; Accuracy: (2.5% of reading + 1mA)

HF leakage current

Fixed load: 200 V; Accuracy; V Accuracy: 2.5%


Power rating: 400 W; Additional fixed load: 200 ; Current, RMS: 0 mA to 5500 mA; Accuracy: (2.5% of
reading + 1 mA)

CQM Test (contact quality


monitor)

Resistances: 0 to 475 (by 1 ); Accuracy: 0 to 10 0.5 , 11 and above 5%; Power rating: 0.5 W;
Auto time interval: 1 to 5 seconds

Oscilloscope output

1 V per ampere of input current, typical

Footswitch simulations

Cut and coag

Communications

USB device port: Micro B connector, full speed; Wireless port: 802.15, Speed: 115,200 baud

Memory

Test records: 5,000; Non-volatile: retained through power cycling

General information
Display

Monochrome 240 pixels x 64 pixels, 8 lines x 40 characters, white LED backlight

Power

100 V ac, 115 V ac, 230 V ac, 50 Hz / 60 Hz, universal input, 100 V/115 V: 20 VA, 230 V: 30 VA

Dimensions (LxWxH)

14.5 cm x 35 cm x 47 cm (5.75 in x 13.75 in x 18.5 in)

Weight

7.5 kg (16.5 lbs)

*Wireless capabilities not available in all countries. Ask your sales representative for more details.

For full specifications please visit www.flukebiomedical.com//QA-ES-III


Electrosurgical Analyzer

Infusion Device Analyzers


Comparison Guide

IDA-1S

IDA-5 4Ch

Flow rate range

0.5 to 1000 ml/hr

0.5 to 1500 ml/hr

Flow rate accuracy

1% of reading + 1 LSD
for 16 ml/hr to 200 ml/hr & Vol. >20 ml
or, 2% of reading + 1 LSD (Vol. >10 ml)

1% of reading + 1 LSD
for 16 ml/hr to 200 ml/hr & Vol. >20 ml
or, 2% of reading + 1 LSD (Vol. >10 ml)

Volume measurement

0.06 to 999 ml

0 to 9999 ml

Dual flow measurement

No

Yes

Onboard graphing of pressure


and flow

No

Yes

Number of channels

Min. volume detection

60 l

60 l

AutoStart (Vol. detection)

Yes

Yes

PCA measurements

No

Yes

Occlusion test range

0 to 45 PSI and equivalents in


mmHg, Bar and kPa

0 to 45 PSI and equivalents in


mmHg and kPa

Occlusion test accuracy

1% of full scale + 1 LSD

1% of full scale + 1 LSD

Back pressure

-100 mmHg to + 300 mmHg

Application software

Included
HydrogrGraph Remote Control
and Data Analysis Software

Included
HydrogrGraph Remote Control and
Data Analysis Software (included)

Automation SW
(Broadbase automation)

No

Yes

Printer compatible

No

Plug n Play

Battery operated

Yes

No

Barcode scanner

No

Plug n Play

Keyboard

Touch-Screen

Plug n Play

Memory (on board)

Yes

Yes

Trumpet curve

No

Yes

Weight

2.7 lbs

11 lbs

Infusion Device Analyzers

IDA-5

Infusion Device Analyzer


Representing 20 years of experience in
infusion pump testing, the IDA-5 Infusion
Device Analyzer can digitally verify a pump
is administering flow, volume and boluses
accurately, and the pump is alarming upon
occlusion as expected. The IDA-5 has
built-in automation allowing users to create
custom test templates for quick, standardized testing with minimal user intervention.
This automation bundle includes Ansur
software for comprehensive testing.

Instrument CarePlans

Si

er

ze

Biomedical Products

lv

Br o

HydroGraph Graphics Software


Use the moving-color visual advantage of
HydroGraph to troubleshoot up to four infusion
pumps at once. Data is taken directly from the
transducer and transmitted to HygroGraph. The
flowing graphs provide an electronic means
to display, store and recall flow patterns for
comparison at a later date. Each test window
can display instantaneous and average flow
rates, cumulative, and bolus volumes; and
occlusion pressure.

Key features
Tests up to four infusion pumps
at the same time
Customizable test templates for
quick and standardized testing
On-board and PC-based
automation to fully test to
IEC60601-2-24 testing requirements for quick standardized
testing
Compatible with virtually any
type of infusion device
Real time snap shots of flow and
pressure for immediate issue
recognition
Instantaneous and average
flow measurement of up to
1500 ml/hr
Occlusion pressure measurements to 45 psi
Single-flow, dual-flow (piggyback) and PCA testing
Auto-start mode enables unit to
begin testing only when fluid is
detected to maximize accuracy
Ability to automatically end flow
measurement based on userdefined time, volume or both
Convenient and easy data entry
with plug-n-play, USB compatible, keyboard or barcode
scanner
Built-in memory to save
test results for printing or
downloading to computer

Included accessories

Specifications
Flow rate measurement
Range

0.1 ml/h to 1500 ml/h (2600 ml/h is shown)

Accuracy

1 % of reading 1 LSD for flows of 16 to 200 ml/h for volumes


over 20 ml; otherwise 2 % of reading 1 LSD for volumes over
10 ml under laboratory conditions.

Volume measurement
Range

0.06 ml to 9999 ml

PCA bolus/dual flow measurement


Minimum bolus volume

0.5 ml

Resolution

60 ul increments

4418071 Hydrograph Software and


User Manual
4354014 20 ml syringe
4354038 3-way Luerlock
4354429 5-ft Plastic Drain Line
4354452 USB A-B Cable 2M

Optional accessories
4354490 Optional Miniature Keyboard
4354503 Ansur Test Software, IDA-5
Plug-In License
4354532 One Channel Upgrade Option

Pressure measurement
Range

0 psi to 45 psi and equivalents in mmHg and kPa

Accuracy

1 % of full scale 1 LSD under laboratory conditions

For full specifications please visit www.flukebiomedical.com/IDA5

Infusion Device Analyzers

IDA-1S

Infusion Device Analyzer


A unique mix of speed and technical precision, the IDA-1S is the ideal analyzer for quick
reliable one-channel measurements while onthe-go.
Its a portable, battery-operated instrument
that allows for speedy verification of infusion
device performance.
The IDA-1S measures the flow rate and
volume delivered, and the pressure generated
in occlusions or blockages of the fluid line. The
IDA-1S is based on sophisticated measurement
technology trusted by biomedical professionals
around the world.
It is easy to set up and requires little or no
training to use. The IDA-1S can be used to test
a wide variety of infusion pumps and an autostart feature simplifies syringe pump testing
and other tests that have long startup times.

Instrument CarePlans

Si

er

ze

Biomedical Products

lv

Br o

Specifications
Flow rate measurement
0.5 ml/h to 1000 ml/h

Accuracy

1 % of reading 1 LSD for flows of 16 ml/h to 200 ml/h


for volumes over 20 ml; otherwise 2 % of reading 1 LSD
for volumes over 10 ml under laboratory conditions

Max test duration

10 hours on battery

Volume measurement
0.06 ml to 999 ml

Accuracy

1 % of reading 1 LSD for flow rates of 16 ml/h to 200 ml/h


for volumes over 20 ml; otherwise 2 % of reading 1 LSD for
volumes over 10 ml under laboratory conditions

Max test duration

10 hours on battery

Pressure measurement
Range

0 psi to 45 psi and equivalent in mmHg, Bar and kPa

Accuracy

1 % of full scale 1 LSD under laboratory conditions

Max test duration

10 hours on battery

For full specifications please visit www.flukebiomedical.com/IDA1S

10

Infusion Device Analyzers

Integrated carrying handle and


lightweight (2.7 lb) for easy
portability
Battery powered with up to
10 hours of continuous operation
for on-the-go operation
LCD touch screen for ease of use
Average and instantaneous flow
measurement
Occlusion pressure measurements to 45 psi
Maximize accuracy with
Autostart mode enabling unit to
begin testing only when fluid is
detected
Compatible with a wide variety
of infusion pumps
Based on technology that is
proven and trusted worldwide
On-board memory allows test
results storage instantly
Hydrograph graphical software
to control unit,display results
and print results via PC
Global sales, service and support

Included
accessories

Range

Range

Key features

4418071 Hydrograph Software and


Users Manual
4497350 20 ml syringe
4480978 3-way Luerlock
4478942 Drain tube (1 m)
4541948 Micro-90 solution (225 ml)
1740487 USB data transfer cable
2461300 Country-specific adapters
4329971 Power Supply
4481150 NiMH replacement battery

Electrical Safety
Comparison guide
Do you need
25A PE test
current
capability?

Do you prefer
an analyzer
with on-board
automation?

NO

YES

NO

YES

YES

We recommend the

Do you need
to test applied
parts?

We recommend the

ESA620

ESA615

We recommend the

YES

ESA612

NO

We recommend the

ESA609

ESA615

ESA612

ESA620

ESA609

601 Pro SeriesXL

IEC62353
and NFPA-99

ANSI/AAMI
and NFPA-99

IEC60601-1
2nd, 3rd edition

ANSI/AAMI
and NFPA-99

IEC60601-1
2nd edition

Basic overview
Preferred analyzer for
which standard?
Automation inside

Ansur compatible

Onboard memory

ECG simulation

Handheld

GFCI protection

DUT load current

20 A test capability

25 A test capability

Detailed comparison
Test modes

Automated
Manual if preferred

Manual
Ansur-automatable

Manual
Ansur-automatable

Manual

Automated (limited;
manual testing
required to meet
newest standards)

Test loads

AAMI, IEC60601-1

AAMI, IEC60601-1

AAMI, IEC60601-1,
IEC61010

AAMI, IEC6060-1

AAMI, IEC60601-1,
IEC61010

Mains voltage
measurement

All lines

All lines

All lines

All lines

All lines

PE test current

200 mA ac

200 mA ac

200 mA ac, 25 A ac

>200 mA dc

1 A ac, 10 A ac,
25 A ac

Leakage range

0 A t0 10,000 A
0 A to 20 mA
(differential only)

0 A t0 10,000 A
0 A to 20 mA
(differential only)

0 A t0 10,000 A
0 A to 20 mA
(differential or
61010 only)

0.0 A to 1999.9 A

0 A to 8000 A to
16,000
(61010 only)

Patient auxiliary leakage


lead selections

Any 1 to all

Any 1 to all

Any 1 to all
RA-LL-LL-LA RA-LA

MAP test voltage

100% of mains

100% of mains

110% Or 100%

Power supply (V ac)

120 or 230

120 or 230

120 or 230

Applied parts connections

5 banana safety
jacks, Bj2ECG
adapter, 1-to-10
Expander

5 banana safety
jacks, Bj2ECG
adapter, 1-to-10
Expander

10 insulated posts

10 banana safety
jacks

Communication options

Wireless and Wired

Wired

Wired

Wired

Data entry options

Onboard keypad
USB compatible
keyboard, Barcode
scanner

Onboard keypad

Printer port

Available via Ansur

Available via Ansur

Available via Ansur

Parallel

Dual lead testing

A/mV, V and

A/mV, V and

A/mV, V and

A/mV and V

Connectivity

USB

USB

USB

RS-232,
parallel printer

Power cord

Removable

Removable

Removable

Removable

Any 1-5 to all


V1-16 to all
110% of mains
90 to 264

120 or 230

Onboard keypad
PS/2 keyboard
Barcode scanner

Electrical Safety Analyzers

11

ESA609

Electrical Safety Analyzer

Instrument CarePlans

Si

lv

er

ze

Biomedical Products

Br o

The ESA609 Electrical Safety Analyzer is a rugged, portable and easy-to-use


analyzer designed for general electrical safety testing. Engineered for on-thego technicians, the ESA609 requires no training to use and has a rubberized
case that allows it to sustain the rigor of transportation, and helps prevent
damage when accidentally dropped.
Additionally, its functional strap and featherweight design make it one of
the most portable electrical safety analyzers in its class. Heavy-duty switches
allow users to effortlessly change polarity and configuration of the neutral
connection between open and closed, while push-button operation ensures
fast transition between tests for complete basic testing in minutes. The ESA609
integrates all functions needed to test medical devices when patient lead testing is not required, including: line (mains) voltage, ground wire (protective
earth) resistance, equipment current, leakage current and point-to point tests.
Versatile to global electrical safety standards of choice, the ESA609 tests to
ANSI/AAMI ES1, NFPA-99, and parts of IEC62353 and IEC60601-1.

Specifications
Mains voltage measurement
Range

90.0 V to 264.0 V ac rms

Accuracy

(2 % of reading + 0.2 V)

Key features
Standards compliance include:
ANSI/AAMI ES1, NFPA-99,
and parts of IEC62353 and
IEC60601-1
Test current consumption up to
20 A for a diverse set of medical
devices
All parameters needed for basic
electrical safety testing: line
(mains) voltage, ground wire
(or protective earth) resistance,
equipment current, ground wire
(earth) leakage, chassis (enclosure) leakage, direct equipment
leakage, and point to point leakage and resistance
Global use: the ESA609 will
operate at 120 V and 230 V
Rugged: Rubberized case and
Ingress Protection rating of IP30
help prevent damage when
dropped
User-friendly: Quick push-button
operation for rapid testing
Portable: Featherweight (1.5 lb)
design, functional strap, and tilt
stand make it easy for transportation and operation on-the-go
(onsite or offsite)
Rigorously tested for safety and
reliability, with CE, CSA and
Australia RCM in addition to
Fluke quality

Earth resistance
Modes

Two wire

Test current

> 200 mA dc

Range

0.000 to 20.000

Accuracy

(1 % of reading + 0.010 )

Resistance tests

Earth resistance and point to point

Modes

True-rms

4370089 Operators manual


(Multilingual CD-ROM)
4370092 Safety sheet
3111008 USA/AUS/ISR Accessory
Kit: test lead set, TP1 test probe set,
AC285 alligator clip set (ESA T/L kit,
USA)
3326842 Null post adapter
2248650 Carrying case
Line cord Country-specific power cord
3111024 EUR Accessory Kit: test lead
set, TP74 test probe set, AC285 alligator clip set (ESA T/L kit, EUR)

Patient load selection

AAMI ES1-1993 Fig. 1


IEC 60601: Fig. 15

Optional accessories

Crest factor

Less than or equal to 3

2195732 15 A to 20 A adapter

Ranges

0.0 A to 1999.9 A accuracy

DC to 1 kHz

1 % of reading + (1 A , whichever is greater)

1 kHz to 100 kHz

2.5 % of reading + (1 A, whichever is greater)

100 kHz to 1 MHz

5 % of reading + (1 A, whichever is greater)

Leakage tests

Ground wire (earth)


Chassis (enclosure)
Direct equipment
Point to point

Equipment current
Mode

AC RMS

Range

0.0 A to 20.0 A

Accuracy

5 % of reading + (2 counts or 0.2 A, whichever is greater)

Duty cycle

15 A to 20 A, 5 min. on/5 min. off


10 A to 15 A, 7 min. on/3 min. off
0 A to 10 A, continuous

Leakage current

For full specifications please visit www.flukebiomedical.com/ESA609


12

Included accessories

Electrical Safety Analyzers

ESA612

Electrical Safety Analyzer


Portable, lightweight and designed for operation in tight spaces, the ESA612 Electrical
Safety Analyzer offers the functionality of a
simulator, multimeter and analyzer in a single
test tool. The versatility of the multifaceted
ESA612 is further expanded with optional
automation software, which speeds and
simplifies testing and provides high-end productivity at software-level investment.

Instrument CarePlans

Si

er

ze

Biomedical Products

lv

Br o

Specifications

Key features
Large, easy-to-read display with
adjustable contrast
Human-factors-designed user
interface
Tilt stand design for stand-up
testing in field environments
Five applied parts jacks and
easy ECG snap connection with
optional expander box
ECG waveform tests and duallead measurements combine
the functionality of a simulator,
multimeter and safety analyzer
in a single test tool
Replaceable mains fuses keep
your unit in the field and out of
the repair shop
Internal memory for 100 test
records
USB connection for use with
Ansur and Data Viewer software
(for memory download to PC)

Voltage
Range (mains voltage)

90 V ac to 132 V ac rms, 180 V ac to 264 V ac rms

Range (accessible voltage)

0 V ac to 300 V ac rms

Accuracy

(2 % of reading + 0.2 V)

Voltage tests

Mains and point-to-point

Earth resistance
Mode

Two terminal

Test current

> 200 mA ac

Range

0 to 2

Accuracy

(2 % of reading + 0.015 )

Resistance tests

Earth resistance and point-to-point

Equipment current
Mode

AC rms

Range

0 A to 20 A

Accuracy

5 % of reading + (2 counts or 0.2 A, whichever is greater)

Duty cycle

15 A to 20 A, 5 min on/5 min off


10 A to 15 A, 7 min on/3 min off
0 A to 10 A continuous

Leakage current
Modes*

AC + DC (true-rms)
AC only
DC only

*Modes are available in all leakage tests with the exception of MAP leakages that are available only in true-rms

Crest factor

Ranges

0 A to 199.9 A
200 A to 1999 A
2 mA to 10 mA

For full specifications please visit www.flukebiomedical.com/ESA612

Included
accessories
CD-ROM Users Manual (multilingual)
Manual Getting-Started Guide (hard
copy, multilingual)
Cable Assembly Data Transfer Cable
ESA612 Accessory Kit (country
specific)
2719-0154 15 A to 20 A Adapter
(US only)
ESA620-npa Null Post Adapter
ESA612-2016 5-to-5 Banana Jack to
ECG (BJ2ECG) Adapter
9530-0075 Carry Case Detachable
Power Cord (country specific)
Included accessories for ESA612
with test automation
All of the above, plus:
ANSUR ESA612 Ansur TestAutomation Software ESA612 plug-in

Optional accessories
1903307 Retractable Test Leads
2242165 Ground Pin Adapter (US
receptacle testing ground lug)
3392119 1210 Adapter Box Assembly
3454829 Ansur ESA612 Plug-In
License Key

Electrical Safety Analyzers

13

ESA615

Electrical Safety Analyzer


The automated ESA615 Electrical Safety
Analyzer brings fast and simple testing to a
portable analyzer perfect for use in the field
and in facilities. Whether it is simple testing
or comprehensive analysis, the ESA615 can
do it all. The multifaceted device performs all
primary electrical safety tests including line
(mains) voltage, ground wire (protective earth)
resistance, insulation resistance, device current and lead (patient) leakage tests.

Instrument CarePlans

Si

er

ze

Biomedical Products

lv

Br o

Specifications
Voltage
Range (mains voltage)

90 V ac rms to 132 V ac rms, 180 V ac rms to 264 V ac rms

Range (accessible voltage)

0 V ac rms to 300 V ac rms

Accuracy

(2 % of reading + 0.2 V)

Voltage tests

Mains and point to point

Earth resistance
Mode

Two wire

Test current

> 200 mA ac

Range

0 to 2

Accuracy

(2 % of reading + 0.015 )

Resistance tests

Earth resistance and point to point

Key features
On-board automation with automated test sequences for easy
compliance to key global electrical safety standards (ANSI/
AAMI ES-1 (NFPA-99), IEC62353
(VDE751), IEC60601-1 2nd and
3rd editions, and AS/NZS 3551)
Portable, ergonomic design with
an integrated handle and tilt
stand
Human-factors-designed user
interface for streamlined testing
ECG waveform tests and duallead measurements combine
the functionality of a simulator,
multimeter and safety analyzer
in a single test tool
Five applied parts jacks and
easy ECG snap connection;
optional expander box for up to
12-lead ECG testing
Easy data entry through barcode, external keyboard or
on-board keypad
Wireless communication plus
removable memory card for fast
and convenient data storage and
exchange
Replaceable mains fuses keep
your unit in the field and out of
the repair shop
Custom language selections
include: English, French,
German, Spanish, Italian and
Portuguese

Equipment current
Mode

AC rms

Range

0 A to 20 A

Accuracy

5 % of reading + (2 counts or 0.2 A, whichever is greater)

Duty cycle

15 A to 20 A, 5 min on/5 min off


10 A to 15 A, 7 min on/3 min off
0 A to 10 A continuous

Leakage current
Modes*

AC + DC (true-rms)
AC only
DC only

*Modes are available in all leakage tests with the exception of MAP leakages that are available only in true-rms.

Patient load selection


(input impedance)

AAMI ES1-1993 Fig. 1, IEC 60601: Fig 15

Crest factor

Ranges

0 A to 199.9 A
200 A to 1999 A
2 mA to 10 mA

For full specifications please visit www.flukebiomedical.com/ESA615

14

Electrical Safety Analyzers

Included
accessories
CD-ROM Users Manual (multilingual)
MANUAL Getting Started Guide (hard
copy, multilingual)
Ansur Plug-in CD with demo version
Data Transfer Cable
USA Accessory Kit: Test Lead Set, TP1
Test Probe Set, AC285 Alligator Clip Set
(ESA T/L KIT USA)
15 20 A Adapter (2719-0154)
Null Post Adapter (ESA620-NPA)
5-to-5 Banana Jack to ECG (BJ2ECG)
Adapter (ESA612-2016)
Carrying Case (9530-0075)
Power Cord US (Line Cord)

ESA620

Electrical Safety Analyzer


Key features
Instrument CarePlans

Si

er

ze

Biomedical Products

lv

Br o

The multifaceted ESA620 Electrical Safety Analyzer performs all primary safety
tests including mains voltage, protective earth resistance, insulation resistance,
device current, earth, chassis, and patient leakages as well as several additional leakage tests to comply with standards of choice.
DSP technology offers better accuracy of leakage measurements throughout
the ranges specified in the standards.
Equipped with ten safety-enhanced ECG posts, the ESA620 offers simulation
of ECG and performance waveforms so both electrical safety and basic tests on
patient monitors can be performed with a single connection. When used with
the optional Ansur computer-based software plug-in, the ESA620 becomes
automated. This allows for standardization of test procedures, capturing and
storage of results, comparison to standard limits, and printing of reports thus
enabling the sophisticated performance of the high-end electrical safety
analyzers.

Specifications
Voltage
Range (mains voltage)

120 V model: 90 V ac to 132 V ac rms


230 V model: 180 V ac to 264 V ac rms

Accuracy

(2 % of reading + 1 V)

Range (accessible voltage)

0 V ac to 300 V ac rms

Accuracy

(2 % of reading + 2 LSD)

Voltage tests

Mains, Accessible, and Point to Point

Earth resistance
Modes

Two terminal or four terminal

Test current

> 200 mA ac or 10 A ac to 25 A ac

Ranges

0 to 2

Accuracy

(2 % of reading 0.015 )

Equipment current
Mode

AC rms

Range

0 A to 20 A

Accuracy

5 % of reading (2 counts or 0.2 A, whichever is greater)

Leakage current
Patient load selection
(input impedance)

AAMI ES1-1993 Fig 1


IEC 60601: Fig 15
IEC 61010: Fig A-1

Crest factor

Ranges

0 A to 199.9 A
200 A to 1999 A
2.0 A to 10.0 mA

Frequency response

DC to 1 kHz
1 kHz to 100 kHz
100 kHz to 1 MHz

Accuracy

(1 % of reading + 1 A or 1 LSD, whichever is greater)


(2 % of reading + 1 A or 1 LSD, whichever is greater)
(5 % of reading + 1 A or 1 LSD, whichever is greater)

Superior compliance with


multiple standards: IEC606011(partial), IEC62353, VDE 751,
ANSI/AAMI ES1:1993, NFPA-99,
AN/NZS 3551, IEC61010
Expanded leakage ranges
through 10,000 A
Dual-lead resistance, leakage
and voltage tests
AC only, dc only and true-rms
leakage readings
100 % and 110 % mains voltage
for mains on applied parts (lead
isolation) test
DSP filter technology for
improved accuracy in leakage
measurements
More applied parts selections
ECG and performance
waveforms
Intuitive user interface
Easy-to-use applied parts (ECG)
connections
Insulation posts on applied parts
connections
Five different insulation tests
Varying insulation test voltage
500 V dc and 250 V dc
Two or (optional) four-wire
ground wire resistance
Optional Ansur plug-in software
USB connection
CE, C-TICK and CSA for USA and
Canada
RoHS compliance
Optional Ansur test automation
software to standardize testing
procedures, capture waveforms
and print and document test
result

Included accessories
CD-ROM Users Manual
Manual Multilingual Getting Started
Guide
ESA620 Accessory Kit (country
specific)
2719-0154 15 A to 20 A adapter
(US only)
Soft Case Carry case Detachable
Power Cord (country specific)
Included accessories for ESA620
with test automation
All of the above, plus:
ANSUR ESA620 Ansur TestAutomation Software ESA620 plug-in
Cable Assembly Data Transfer Cable

Optional accessories
ANSUR ESA620 Ansur ESA620 Plug-In

For full specifications please visit www.flukebiomedical.com/ESA620


Electrical Safety Analyzers

15

ProSim Vital Signs Simulator Family


Comparison guide

Functions
ECG simulation

ProSim 8 +
SPOT

ProSim 8

ProSim 4,
ProSim 3,
SPOT Light

ProSim 4

ProSim 3

ProSim 2

Arrhythmia
waveform
selection

50+

50+

11

43

43

43

Respiration
simulation

IBP simulation
(channels)

Pressure relief
test

Fetal ECG/IUP
simulation

Temperature
NIBP simulation
Manometer
(pressure meter)
Leak test

Cardiac output
Rainbow SET
(Masimo) test

Optical SpO2

SPOT Light

Features
Multi-parameter
simulation

Presets,
auto sequences

PC control
software(Ansur)

Direct data saving


and printing

Communication

USB, USB,
wireless

USB, USB,
wireless

USB

Display

LCD color

LCD color

9 hours

9 hours

Multi-language

Barcode scanning
Wireless control
Remote operation

Battery life

16

Patient Simulators

USB

USB

USB

USB

Touchscreen

Touchscreen

LCD gray

LCD gray

LCD gray

4 hours

4 hours

8 hours

8 hours

10 hours

ProSim 3 and ProSim 2


Vital Signs Simulator

Key features

Instrument CarePlans

Si

er

ze

Biomedical Products

lv

Br o

Dont need a comprehensive patient monitor tester? The ProSim 3 and


ProSim 2 Vital Signs Simulators are clear choices for biomedical engineers
and field service technicians that need a quality, portable device. Choose
one of these modern vital signs simulators for preventive maintenance,
troubleshooting and repair.
The ProSim 3 and 2 feature the perfect amount of features for testing in
the field. We like to call it the just-right feature set, and it includes:
ECG
Pacemaker
Arrhythmia and performance testing
Respiration
Invasive blood pressure
Temperature
Cardiac output (ProSim 3 only)
Fetal/maternal (ProSim 3 only)

Portable, multi-parameter
patient simulators for evaluating the performance of patient
monitors
20% lighter and 25% smaller
than predicate technology
Just-right feature set includes:
ECG, pacemaker, arrhythmia and performance testing,
respiration, invasive blood
pressure, temperature, cardiac
output (ProSim 3 only), fetal/
maternal (ProSim 3 only)
43 high-quality waveforms
With four IBP channels, ProSim 3
can test even the highest acuity
scenarios
Stay connected ECG posts for
secure lead connections
Improved user interface and
online Advantage Training
demos
Upgraded DIN connectors ensure
consistency with the ProSim
family; minimize cable compatibility issues
Field upgradeable, and easily
paired with other devices for
comprehensive testing

Included accessories

Specifications
Standard compliance

CE, CSA, C-tick, WEEE and RoHs

ECG rate

30 BPM, 40 BPM, 45 BPM, 60 BPM, 80 BPM, 90 BPM,


100 BPM, 120 BPM, 140 BPM, 160 BPM, 180 BPM, 200 BPM,
220 BPM, 240 BPM, 260 BPM, 280 BPM and 300 BPM

ECG accuracy

1% of setting

Arrhythmia

43 waveforms

Respiration rate

0 (OFF), 15 BPM, 20 BPM, 30 BPM, 40 BPM, 60 BPM, 80 BPM,


100 BPM, 120 BPM

Accuracy baseline

5%

Blood pressure

4 channels

Pressure accuracy

(2% of setting + 2 mmHg), dc excitation only

Temperature

0 C (32 F), 24 C (75.2 F), 37 C (98.6 F), 40 C (104 F)

Temperature accuracy

0.1 C

Cardiac output

2.5, 5, 10 liters per minute 5 %

Fetal/maternal

Fetal HR: 60 BPM, 90 BPM, 120 BPM, 140 BPM, 150 BPM,
210 BPM and 240 BPM
Fetal HR (IUP): 140 BPM, then varies

For full specifications please visit www.flukebiomedical.com/ProSim

ProSim 2/3 Instruction Sheet


(Multilingual)
4253822 ProSim 2/3 Users Manual CD
614487 Two 9-volt alkaline batteries
(minimum eight hours continuous use)
2392173 IBP Cable, unterminated
2392199 3010-0289FG, CI-3 Cable
Assembly (Cardiac Output Box;
ProSim 3 only)
1671807 USB cable
2248623 ProSim 2/3 Carrying Case

AC power cords

4219453 AC/DC Power Supply


769422 AC Power Cord (Schuko)
284174 AC Power Cord (USA)
769455 AC Power Cord (UK)
658641 AC Power Cord (Australia)
2200218 AC Power Cord (Denmark)
2200229 AC Power Cord (India)
2200241 AC Power Cord (Israel)
2198785 AC Power Cord (Italy)
769448 AC Power Cord (Switzerland)

Optional accessories
2523334 YSI 400 Series (UT-4)
2199019 YSI 700 Series (UT-2)
4022300 Cardiac output switch for GE

Patient Simulators

17

ProSim 4 with SPOT Light

Vital Signs Simulator and SpO2 Functional Tester


The ProSim 4 Vital Signs Simulator
offers quick and simple one-tap testing
for patient monitor performance checks
and troubleshooting. Designed to get
you in and out of most locations in
60 seconds, this quick-check device
offers 12-lead ECG simulation, respiration, IBP and NIBP testing in the palm
of your hand. Featuring specialized
stay-connected ECG posts to ensure
secure lead connections and no-hassle
testing, the ProSim 4 is the perfect
patient simulator for first-call patient
monitor quality assurance and safety
professionals.
The ProSim SPOT Light SpO2 Tester
is the first comprehensive Sp02 tester
to come in a handheld and easy-touse device. It's lightweight and flexible
with three custom presets specially
designed to make it the fastest and
easiest to use device on the market for
pulse oximeter functional testing.

Instrument CarePlans

Si

er

ze

Biomedical Products

lv

Br o

Specifications
Standard compliance

CE, CSA, C-Tick, RoHs

ECG rate

30 BPM, 60 BPM, 80 BPM, 90 BPM, 120 BPM, 150 BPM,


180 BPM, 210 BPM, 240 BPM, 270 BPM, 300 BPM, and
320 BPM

ECG accuracy

1% of setting

Arrhythmia

11 waveforms

Respiration rate

0 (OFF), 10 BrPM to 100 BrPM in 10 BrPM steps

Accuracy baseline

5%

Manometer (Pressure meter)

10 mmHg to 400 mmHg

Manometer resolution

0.1 mmHg (for display purposes)

Manometer accuracy

(1% of reading + 1 mmHg)

Invasive blood pressure

One channel

Pressure accuracy

(1% of setting + 1mmHg), dc excitation only

Temperature

0 C (32 F), 24 C (75.2 F), 37 C (98.6 F), 40 C (104 F)

For full specifications please visit www.flukebiomedical.com/ProSim

18

Patient Simulators

Key features
ProSim4

ProSim 4 is a multi-function
tester offering 12-lead ECG, respiration, IBP and NIBP simulation
Touchscreen interface
One-tap testing for most performance tests and checks
Easy quick-check patient monitor testing

SPOT Light

SPOT Light preset programs test


any combination of saturation,
heart rate, perfusion, transmission, artifact noise, and r-curve
in 15 seconds or less
Small, portable and lightweight
Rechargeable battery lasts 10
hours minimum
Signal strength indicator
SpO2 saturation: 80%, 85%,
90%, 95%, 97%, 98%, 99%
and 100%
Heart rate: 30, 60, 80, 100, 120,
150 and 245 BPM
Perfusion: 0.2%, 2% and 10%
Transmission: dark/thick,
normal and light/thin
Artifacts: respiration and
ambient light
R-curves: Nonin, Masimo,
Nellcor, Nihon Kohden, Mindray,
GE, Philips, BCI

Optional accessories
3984878 ProSim 4 Accessory Kit,
includes: Unterminated IBP cable,
HP-3 IBP cable, MQ-3 IBP cable, TK-1
IBP cable, Adult cuff Mandrel spacer
block (3), Adult cuff Mandrel end block
(2), Neonatal Mandrel, USB cable,
Spare Battery pack, ECG Snap/banana
adapter
2392328 Neonatal Cuff Mandrel
2392370 Adult Cuff Mandrel End
Blocks (2 needed)
2392381 Adult Cuff Mandrel Spacer
Blocks (3 needed)
4026551 ECG Snap Adapter 4 mm and
3.2 mm ECG Banana Adapter Converter
Modules (international only)

ProSim 8

Vital Signs Simulator

Instrument CarePlans

Si

er

ze

Biomedical Products

lv

Br o

The 8-in-1 ProSim 8 Vital Signs


Simulator offers fast and comprehensive preventive maintenance (PM)
testing for your entire patient monitor
fleet. Designed to get you in and out
of most PM locations in minutes, this
multifunction simulator tests ECG
(including fetal ECG and arrhythmias), respiration, temperature, IBP,
cardiac output/cardiac catheterization, NIBP, SpO2, and is capable of
testing Rainbow multi-wavelength
waveforms. Featuring specialized
stay-connected ECG posts for secure
lead connections, physiologicallysynchronized pulses across all
parameters, and customizable patient
pre-sets and autosequences, the
ProSim 8 provides unbeatably fast
and easy complete monitor testing.

Specifications
Normal-sinus-rhythm waveform
Normal sinus
rhythm

12-lead configuration with independent outputs referenced to right leg (RL).


Output to 10 universal ECG jacks, color-coded to AHA and IEC standards

High-level output

0.5 V/mV 5% of the ECG amplitude setting available on a BNC


connector

Amplitude

0.05 mV to 0.5 mV (0.05 mV steps); 0.5 mV to 5 mV (0.25 mV steps)

ECG rate

10 BPM to 360 BPM in 1 BPM steps

ECG waveform
selection

Adult (80 ms) or pediatric (40 ms) QRS duration

ST-segment
elevation

Adult mode only. -0.8mV to +0.8mV (0.1 mV steps).


Additional steps: + 0.05mV and - 0.05mV

Key features
All-in-one complete monitor
testing 80% smaller and 17 lbs
(7.7 kilos) lighter than predicate
technology
Stay-connected ECG posts for
easy/secure ECG snap and lead
connections
Custom SpO2 r-curve for accurate
testing of the latest oximetry
technologies
Static pressure linearity testing
Repeatable NIBP simulation
( 2 mm Hg) for dynamic pressure repeatability testing
Physiologically synchronized
pulses across all parameters
Barcode scanning and
direct data capture, printing
functionality
Onboard, customizable patient
pre-sets and auto sequences for
fast/easy testing
Multi-language user interface offers choice of language
selection
Integrated, easily replaceable,
long-life battery
Wireless communication for
remote PC control of test device,
as well as data transfer and
automated regulatory reporting*
*You must have Ansur Test Executive
version 2.9.6 or greater on your PC to
communicate with the product.

Pacemaker waveform
Pacer pulse

Amplitude

0 (off), 2, 4, 6, 8, 10, 12, 14, 16, 18,


20, 50, 100, 200, 500, and 700 mV for lead II
(reference lead)

Pacer pulse width

0.1ms, 0.2ms, 0.5ms, 1ms, and 2ms 5%

Paced arrhythmias

Atrial 80 BPM
Asynchronous 75 BPM
Demand with frequent sinus beats
Demand with occasional sinus beats
Atrio-ventricular sequential
Noncapture (one time)
Nonfunction

Arrhythmia
Baseline NSR

80 BPM

PVC focus

Left focus, standard timing (except where specified)

Supraventricular
arrhythmia

Atrial fibrillation (coarse or fine); atrial flutter; sinus arrhythmia; missed


beat (one time); atrial tachycardia; paroxysmal atrial tachcardia; nodal
rhythm; and supraventricular tachycardia

Premature
arrhythmia

Premature atrial contraction (PAC); premature nodal contraction (PNC);


PVC1 left ventricular; PVC1 left ventricular, early; PVC1 left ventricular,
R on T; PVC2 right ventricular; PVC2 right ventricular, early; PVC2 right
ventricular, R on T; and multifocal PVCs

Ventricular
arrhythmia

PVCs 6, 12, or 24 per minute; frequent multifocal PVCs; bigeminy; trigeminy; multiple PVCs (one-time run of 2, 5, or 11 PVCs); mono-ventricular
tachycardia (120 to 300 BPM in 5 BPM steps); poly-ventricular tachycardia
(5 types); ventricular fibrillation (coarse or fine); and asystole

Optional accessories
2392199 CI-3 Cardiac Output Box
3408564 Mini-DIN to DIN IBP Adapter
3890640 NIBP Test Chamber 500 ML
4034627 Ansur Test Software ProSim
8 Plug-In
Cable kits
3984910 ProSim 8 Accessory Kit
(includes DIN to minDin adapter,
HP/Philips Intellivue IBP cable, GE
Marquette Eagle/Dash/Solar IBP
cable, Welch Allyn Propaq/SpaceLabs
Ultraview IBP cable, USB wireless
dongle, YSI400 series temperature
cable, YSI700 series temperature cable,
CI-3 Cardiac Output Box, spare battery
pack)
3984922 HP/Philips Intellivue Cable Set
3984968 GE Marquette Eagle/Dash/
Solar Cable Set
3984946 ProSim 8 SpaceLabs
Ultraview Cable set
3984979 Welch Allyn/Propaq Cable Set
3984993 Drager Infinity Cable Set
3985009 ProSim 8 Nihon Kohden
Cable Set
Patient Simulators

19

ProSim 8

Vital Signs Simulator


Arrhythmia continued
Conduction defect

First-, second-, or third-degree heart block; and right- or left-bundle-branch block

Advanced cardiac life


support

Shockable pulseless arrest rhythms

Ventricular fibrillation (coarse), ventricular fibrillation (fine), unstable


polymorphic ventricular tachycardia

Non-shockable pulseless arrest rhythms

Asystole

Symptomatic bradycardia

Sinus bradycardia (< 60 BPM)


2nd degree AV block, mobitz type I
2nd degree AV block, mobitz type II
Complete/3rd degree AV block
Right bundle branch block
Left bundle branch block

Symptomatic tachycardia: regular narrowcomplex tachycardia (QRS < 0.12 seconds)

Sinus tachycardia > 150 BPM

Symptomatic tachycardia: regular wide-complex


tachycardias (QRS 0.12 seconds)

Sinus tachycardia > 150 BPM

Irregular tachycardia

Atrial fibrillation (coarse and fine), atrial flutter, unstable monomorphic ventricular tachycardia (120 BPM to 300 BPM), torsade de
pointes/polymorphic ventricular tachycardia (long QT interval)

Supraventricular Tachycardia
Supraventricular tachycardia SVT with aberrancy

ECG Performance testing


Amplitude

0.05 mV to 0.5 mV (0.05 mV steps)


0.5 mV to 5 mV (0.25 mV steps)

Pulse wave

30 BPM, 60 BPM, with 60 ms pulse width

Square wave

0.125 Hz, 2 Hz, 2.5 Hz

Triangle wave

0.125 Hz, 2 Hz, 2.5 Hz

Sine wave

0.05 Hz, 0.5 Hz, 1 Hz, 2 Hz, 5 Hz, 10 Hz, 25 Hz, 30 Hz, 40 Hz, 50 Hz, 60 Hz, 100 Hz, and 150 Hz

R-wave detection

Waveform

Triangular pulse

Rate

30 BPM, 60 BPM, 80 BPM, 120 BPM, 200 BPM, and 250 BPM

QRS detection

Rate

30 BPM, 60 BPM, 80 BPM, 120 BPM, 200 BPM, and 250 BPM

Tall T-wave rejection

Waveform

QT Interval 350 ms
T-Wave width 180 ms
T-Wave shape sinewave

Rate

80 BPM

ECG artifact
Type

50 Hz, 60 Hz, muscular, baseline wander, respiration

Size

25%, 50%, 100% of the normal sinus R-Wave for each lead

Lead select

All, RA, LL, LA, V1, V2, V3, V4, V5, V6

Fetal/Maternal ECG
Fetal heart rate (fixed)

60 BPM to 240 BPM in 1 BPM steps

Fetal heart rate (IUP)

140 BPM at beginning, then varies with pressure

Intrauterine-pressure
waveforms

Early deceleration, late deceleration and acceleration

Wave duration

90 seconds, bell-shaped pressure curve, from 0 mmHg to 90 mmHg and returning to 0

Invasive blood pressure


Channels

2, each independently settable with identical parameters and are individually electrically isolated from all other signals

Transducer sensitivity

5 (default) or 40 V/V/mmHg

Static pressure

- 10 to + 300 mmHg in 1 mmHg steps

Pressure units

mmHg or Kpa

Swan-Ganz sequence

Right atrium, right ventrical (RV), pulmonary artery (PA), pulmonary artery wedge (PAW)

Cardiac catheterization

Chambers

Aortic, pulmonary valve and mitral valve

Respiration artifact

Arterial, radial artery, and left ventricle

5% to 10% multiplication

Other

5 mmHg or 10 mmHg

BP output

Circular DIN 5-Pin

For full specifications please visit www.flukebiomedical.com/ProSim

20

Patient Simulators

VT Gas Flow Analyzer Family


Comparison guide

Which gas flow analyzer is right for you?


Do you need
unique HFOV/
HFJV display?

NO

Would
battery
power be
helpful?

YES

NO

We recommend the

VT Plus HF

YES

Want to
have all
sensors
inside?

We recommend the

NO

VT Mobile

YES

We recommend the

VT305

HFOV: High frequency oscillatory ventilation


HFJV: High frequency jet ventilation

Sensors inside

VT PLUS HF

VT305

One flow-channel covers all flow measurements

Four-button control

Battery powered

Removable SD card memory

Memory playback on-screen

VT MOBILE

Three waveform display

High frequency ventilation measurements

HFOV/HFJV display

Factory preset gas types/density compensations

User-defined gas type/density compensations

RT200 mode

Ansur VT Plug-In compatible

Test lung included in standard accessories

Test lung optional

All parameters displayed on one screen

Gas Flow Analyzers

21

VT PLUS HF

Gas Flow Analyzer


The premier gas flow analyzer.
The VT PLUS HF is Fluke Biomedicals premier general-purpose gas
flow analyzer. With special display
modes and bidirectional flow, the VT
PLUS HF efficiently tests both conventional mechanical ventilators and
high-frequency ventilators. Multiple
special-function tests make troubleshooting quick and efficient. Learning
to use the VT PLUS HF is simple.
Technicians control the unit using the
user-friendly command system, or, if
theyre familiar with the RT-200, they
can switch to a special control mode
that uses RT-200-style commands.

Instrument CarePlans

Si

er

ze

Biomedical Products

lv

Br o

VT305

Gas Flow Analyzer


Simple. Portable. Efficient.
The VT305 Gas Flow Analyzer is the
quick and easy way to test medical
gas flow and pressure devices. This
versatile tool evaluates the performance of a wide variety of devices
and multiple ventilator parameters.
The VT305 features internal sensors to make connecting to medical
devices a fast and easy process. The
four-button front-panel control makes switching to the best view of measured
data simple. Onboard graphing capabilities allow users to view waveforms
right on-screen, and measurements (numeric and waveform data) can be
stored on the units 2 GB SD card with a simple button-touch. Users can upload
these measurements to a computer for viewing or printing using the included
Windows-compatible utility program.

Key features
VT PLUS HF

Bidirectional flow, pressure, volume, oxygen concentration and


pressure measurements
Low- and high-pressure, and
flow measurement capability
Special HF modeup to
900 BPM (15 Hz)
RS-232 and printer ports
Included Windows-compatible
graphics software
All 21 ventilator parameters
displayed at once on one screen
Operation by user-friendly
VT PLUS HF command mode or
special RT-200 command mode
Minimum, maximum, average, absolute and graph for all
parameters
Multiple special-function tests
for efficient troubleshooting

VT305

Bidirectional flow, volume,


vacuum, pressure and oxygen
concentration measurements
Display orients itself horizontally
and vertically
Four-button control
Portable and compact
USB for computer control
2 GB SD card memory for storing
results
Ansur compatible for streamlined standard work and
reporting

VT MOBILE

VT MOBILE

Gas Flow Analyzer


Designed for portability.
The VT MOBILE is a compact and portable general purpose gas-flow analyzer designed to meet the needs of
the traveling technician or engineer. This versatile tool
evaluates the performance of a wide variety of medical
gas-flow/pressure devices, and measures 16 ventilator
parameters.
The base unit measures high- and low-flow
ranges, volume, pressure and oxygen concentration.
Additionally, the temperature and relative humidity
option can be ordered separately to ensure the most
accurate gas-flow measurements.
Instrument CarePlans

Si

er

ze

Biomedical Products

lv

Br o

For full specifications please visit www.flukebiomedical.com//gasflowanalyzers

22

Gas Flow Analyzers

Bidirectional flow (high- and


low-flow ranges), volume,
vacuum, pressure and oxygen
concentration measurements
16 ventilator parameter
measurements
Trending and statistical analysis
of all measured values

Onboard graphical display


Portable and compact
RS-232 for computer control
Memory for storing results
VT for Windows PC software
Optional sensor assembly for
temperature and humidity
measurements

INCU II

Incubator/Radiant Warmer Analyzer


Portable and intuitive-touse, the INCU II Wireless*
Incubator/Radiant Warmer
Analyzer simplifies testing
and verifying the performance of baby incubators,
transport incubators, and
radiant warmers. Compliant
with global IEC standards (IEC
60601-2-19, IEC 60601-2-20
and IEC 60601-2-21), the INCU
II simultaneously measures
temperature in six independent points, sound, humidity,
and airflow.
* Wireless capabilities not available in all
countries. Ask your distributor for more
details.

Specifications
Measurement and test
Air conduction peripheral
temperature sensors for
incubator (T1-T5)

5 sensors; Range: 0 C to 50 C; Accuracy: 0.05 C;


Display resolution: 0.01 C

Air convection temperature


sensors for radiant warmers,
sensors in pucks (black discs)

5 pucks; Range: 0 C to 50 C; Accuracy: 0.2 C; Display


resolution: 0.01 C

Relative humidity

Range: 0% to 100%; Accuracy: 3% RH (0% to 100%,


non-condensing); Display Resolution: 0.1% RH

Airflow

Range: 0.2 m/sec to 2.0 m/sec at 35 C, 50% RH;


Accuracy: 0.1 m/sec; Display Resolution: 0.01 m/sec

Sound pressure

30 dB(A) to 100 db(A); Accuracy: 5 dB(A); Display


resolution: 0.1 dB(A); IEC-61672-1 Class 2 from 31.5Hz to
8kHz

Surface temperature

Range: 5 C to 60 C; Accuracy: 0.5 C; Display


Resolution: 0.05 C

Skin temperature probe with


reference thermometer

Range: 0 C to 50 C; Accuracy: 0.05 C; Display


Resolution: 0.01 C

Key features
Displays pass/fail indicators and
real-time test results on a large
LCD screen
Portable and compact design,
weighs less than 3 lbs (1.4 kg),
or 9 lbs (3.9 kg) including
radiant warmer pucks
Creates personalized test
sequences for automatic test
completion in compliance with
standards
General Test enables flexibility
in testing procedures and simplifies troubleshooting
Simplifies test set-up with colorcoded temperature probes that
match color of input ports
Wireless* functionality supports
fast and convenient downloading of test results and data
Able to choose from 10 different
language interfaces

Optional Accessories
4721175 Skin Temperature
Heater Assembly

Environmental
Operating temperature

10 C to 40 C

Storage temperature

-20 C to 60 C

Humidity

10% to 90% non-condensing

Altitude

2000 m

Ingress protection rating

IP -20

General Information
Display

LCD Color Display, 480 pixels x 272 pixels, 4.3 (10.9 cm),
white LED backlight

Power adapteruniversal
voltage

Input: 100 V to 240 V with adaptors 50 Hz/60 Hz; Output:


15V dc, 1.3 A maximum

Rechargeable lithium-ion
battery, internal

7.4 V, 7800 Ah, 58 Wh; 24 hour battery life with 30


second sample rate

Dimensions (LxWxH)

23 cm x 21 cm x 6 cm (9.0 in x 8.5 in x 2.5 in)

Total weight

3.9 kg (8.5 lb)

*Wireless not available in all countries. Please talk to your local Fluke representative for information about wireless
availability in your country.

For full specifications, please visit www.flukebiomedical.com/INCU_II

Incubator/Radiant Warmer Analyzer

23

Neonatal Test Equipment


NICU Test Solutions

Dale40 Phototherapy Radiometer


Accuracy across blue spectrum.
The Dale40 measures light radiation in
medical devices used to treat hyperbilirubinemia in newborns. It can accurately capture
measurement across the blue color spectrum
from 400-480 nanometers.

Max O2 PLUS AE Oxygen Analyzer


Portable, on-the-go testing.
The Max O2 PLUS AE Oxygen
Analyzer measures the oxygen
concentration in infant incubators, ventilators, anesthesia
systems, or oxygen tanks.
Portable and straightforward
to use, it can capture measurements from 0 % to 100 % with
3% accuracy (actual oxygen
level overfull operating range).

PS320 Fetal Simulator


Test. Troubleshoot. Train.
At week 5, a fetus heart
starts beating, increasing to
155 to 195 beats per minute
prior to birth. The strength
and number of beats can be
measured by a fetal electronic
monitor is used to determine
whether a fetus is in distress.
The PS320 Fetal Simulator
mimics fetal and maternal
heartbeats (ECG), along with
uterine activity during labor
to accurately test and troubleshoot fetal electronic monitors.
For full specifications please visit www.flukebiomedical.com/neonatal

24

Neonatal Test Equipment

Key features
Dale40 Phototherapy
Radiometer
Intuitive to use with LCD screen
Accurate to 5% of full spectral
range of 429-472 nanometers
Measurement range of 0-1999
W/cm2 with 1 W/cm2
Probe lens matches the cosine
receiving function of human skin
Portable, weighing less than
9 ounces with a 9V battery
Verifies output power and provides continuous measurement
of irradiation
Saves costs by eliminating premature replacement of lamps

Max O2 PLUS AE Oxygen


Analyzer
One-touch calibration with
reminder
Long battery life, approximately
5,000 hours
Impact resistant and drip-proof
External Max-25OE Oxygen
Sensor

PS320 Fetal Simulator


Mechanical heart for ultrasound
simulation
TOCO simulation, external or IUP
Ultrasound simulation, including
twins
Maternal ECG simulation
Fetal ECG, tracks ultrasound #1
Internal (DECG) and external
fetal ECG
Uterine-activity selections
Fetal beat-to-beat variability
Periodic and non-periodic fetal
ECG changes
Arrhythmia selections
Compact, lightweight, pocketsize plastic housing
Battery operated with status
indications
Special kits available with all
required accessories and cables
to test fetal monitors for specified manufacturers

Digital Pressure Meters


DPM2Plus

Key features

Universal Pressure Meter

DPM2Plus

The DPM2Plus Universal Pressure Meter is


designed to measure the positive and negative pressures of medical devices in either
liquid or gaseous form to assist in repair and
quality control.

Low-priced pressure meter


Great for all medical pressure
device testing
Optional cable for viewing
pressure waveform on an
oscilloscope (0.1 V/psi on all
ranges except 100 psi, which
is 0.01 V/psi)
Voltage output accuracy: 5%
of range
Can be used with optional
DALE22 Parabolic Flow
Adapter Set

DPM1B
Pnuematic Transducer Tester
The DPM1B Pneumatic Transducer Tester is
designed to measure the positive and negative pressures of medical devices in either
liquid or gaseous form, and to generate pressure within the 300 mmHg range to assist
in repair and quality control.

DPM1B

Low-priced pressure-generator
Great for all pressure transducers, not just IBP

DPM4

Mid-priced pressure and


temperature tester
Great for all medical device
testing where low-pressure,
temperature and low-flow
measurements are required
RS232 for computer control

DPM4
Parameter Tester
DPM4 Parameter Tester is a highly accurate
meter for testing a wide range of medical
devices. Key features include its lightweight,
compact size and battery operation. DPM4
is ideal for the testing done as part of preventive maintenance or repair processes
whenever measurement of pressure, flow, or
relative humidity is required.

DPM1B

DPM2 Plus

DPM4 Model 1

DPM4 Model 2

2 Optional pressure ranges (select at time of purchase)


G range: -700 to +5000 mmHg
H range: 380 to 900 mmHg

Temperature measurement
(-200 to 750 degrees C range)

Pressure generator (positive pressure and vacuum)

Pressure measurement 300 mmHg

5 Selectable pressure ranges standard

Gas flow measurement (750 ml range)


Gas flow measurement (requires DALE22 Parabolic Flow
Adapter set)
10 to 250 l/min (interpretive chart)
10 to 75 l/min (interpretive chart)
5% of reading accuracy

For full specifications please visit www.flukebiomedical.com/PressureMeters


Digital Pressure Meters

25

190M

Medical ScopeMeter Portable Oscilloscope


Taking the guesswork
out of troubleshooting
The 190M Medical
ScopeMeter Portable
Oscilloscope is a highperformance test tool built
upon the legacy of Fluke
and Fluke Biomedical oscilloscopes in partnership
with real customers like
you. The 190M is available with choice of two or
four channels and offers an
unprecedented level of performance, ruggedness and
portability.
With the combined power
of a high-performance oscilloscope, meter and paperless
recorder in an easy-to-use
test tool, the 190M is the
one test tool you can rely on
to tackle just about any troubleshooting task in the field. To minimize downtime
and repair costs, you need to get to the root cause of problems as quickly as possible. The 190M offers a number of unique features to help you quickly set up the
scope and diagnose difficult problems like intermittent events, signal fluctuations
or drift. Extend your arsenal of troubleshooting capabilities with the new Fluke
Biomedical 190M Medical ScopeMeter Portable Oscilloscope, designed to meet the
demands of field service professionals.

Key features
Two or four electrically-isolated inputs
Fast sampling rate, up to 2.5 GS/s on two channels simultaneously with up to
400 ps resolution
Deep memory: 10,000 samples per channel waveform capture so you can
zoom in on the details
Dedicated 5,000 count digital multimeter in two-channel model
Quad meter measurements via scope BNC inputs in four channel model
Connect-and-View trigger for intelligent, automatic triggering on fast, slow
and even complex signals
Frequency spectrum using FFT-analysis
High-resolution, non-interlaced video
Smart averaging
ScopeRecord roll mode gives 30,000 points per input channel and capture
waveform sample data for up to 48 hours
TrendPlot trend measurement readings for up to 22 days
Advanced automatic measurements, power (Vpwm, VA, W, PF) and time
(mAs, V/s, w/s)
Two USB ports make it easy to transfer data to a PC and store unlimited
waveforms, screen captures and instrument setups on USB memory devices
New high-performance Li-ion battery technology delivers the longest battery
life on the market
Charge spare battery door for quick swaps in the field
Security slot locks down oscilloscope with Kensington lock while unattended
Environmentally tested to meet IP-51 and withstand a 3 g vibration or
30 g shock

For full specifications please visit www.flukebiomedical.com/190M

26

Oscilloscope

Included accessories

VPS410-R Voltage probe set, 10:1, 300


MHz, one set red
VPS410-G Voltage probe set, 10:1, 300
MHz, one set gray
VPS410-B Voltage probe set, 10:1, 300
MHz, one set blue
VPS410-V Voltage probe set, 10:1, 300
MHz, one set green
EBC290 External battery charger for
BP290 and BP291
SW90W FlukeView Software for
Windows (full version)
C290 Hard shell protective carrying
case for 190 Series II
BP291 Li-Ion battery pack,
4800 mAh
MA190 Medical Accessory Kit

Optional
accessories

VPS410-R Voltage probe set, 10:1,


300 MHz, one set red
VPS410-B Voltage probe set, 10:1,
300 MHz, one set blue
TL175 TwistGuard safety-designed
test leads set (1 red, 1 black)
EBC290 External battery charger for
BP290 and BP291
SW90W FlukeView Software for
Windows (full version)
C290 Hard shell protective carrying
case for 190 Series II
BP290 Li-Ion battery pack, 2400 mAh
MA190 Medical Accessory Kit

ASM-990

Advanced Survey Meter


The ASM-990 series can detect alpha, beta, gamma, or
x-ray radiation within an operating range of
1 R/hr to 1 R/hr (1 to 5,000,000 CPM), depending on the
selected probe (Geiger-Mueller, neutron,
proportional counter, scintillation). With the proper probe
combination, this meter can be used as a general survey
meter, an area monitor, a wipe-test counter, and a contamination monitor.
Designed to meet the high-technology requirements of
health physics, medical physics, and nondestructive testing
applications, the ASM-990 Series is well-suited for a wide
range of end users, including: Radiation safety officers
(RSO), nuclear medicine laboratories, diagnostic x-ray and
hospital emergency room technicians, environmental health
physicists, and emergency responders.

Key features
Auto-scaling measurement of
rate and dose simultaneously,
with the capability to record
peak rate
Up to five different probes can
be calibrated with one unit
Survey Mode data-logging
feature allows user to store up to
five separate survey sequences
Saved data can be uploaded to
a PC via included Infrared Data
(IrDA) transmitter
Easy-to-use multifunction
keypad for intuitive menu
navigation
Backlit analog/digital LCD
display with full-range audio
output capability
Barcode scanner (optional)
Auto power-down feature
extends battery life

Specifications
Optional accessories

ASM-990 and ASM-992


Operating modes

Rate
Integrate
Scaler (dual option): Based On Measurement or Based On
Time
Timed Peak Hold
Data Logging

Operating rate ranges


(dependent on selected probe)

R/hr, mR/hr, R/hr, rem/hr, mrem/hr, rem/hr, Sv/hr, mSv/


hr, Sv/hr, CPM, CPS, DPM 99mTc, DPS131I, Bq 125I, kBq
123I, MBq 201Tl, Ci 67Ga, mCi18F, Ci 57Co
R, mR, R, rem, mrem, rem, Sv, mSv, Sv, C (counts), kC,
MC, D (distintigrations), kD 99mTc, MC 131I

990-IR-USB USB Port IrDA Adapter


990CC Carrying Case
990WM Wall Mounting Bracket
990PH Probe Holder for 489-110D
990UPH Universal Probe Holder
990SH Soft-Sided Holster
990SA Shoulder Strap Assembly
Note: The shoulder strap assembly is only
available for the ASM-993 and must be
ordered with the instrument and factory
installed.

Complementary units in the integrade mode with the integrated time value in seconds
Accuracy (dependent on
selected probe)

Within 10% of reading between 10% to 100% of full scale


indication on any range, exclusive of typical energy dependence.

Detector

Accepts GM detectors and scintillation probes operating at


high voltages between 500 V and 1300 V

Temperature range

-10 C to 50 C (14 F to 122 F)

Relative humidity

0 % to 95 %, non-condensing

For full specifications please visit www.flukebiomedical.com/ASM-990

Survey Meters

27

451B

Ion Chamber Survey Meter with Beta Slide


Key features

Instrument CarePlans

Si

er

ze

Biomedical Products

lv

Br o

The auto-ranging 451B measures radiation rate and accumulated dose from
beta, gamma and X-ray radiation sources. The 451Bs site surveying capabilities make it well suited for a wide range of end users, including police and
fire departments, X-ray manufacturers, government agencies, state inspectors,
emergency response and HAZMAT teams, nuclear medicine labs, hospital radiation safety officers, and nuclear power workers.
The ion-chamber detector allows for a fast response time to radiation from
leakage, scatter beams and pinholes. Additionally, the low-noise chamber bias
supply provides for fast background settling time. A sliding beta shield serves as
an equilibrium thickness for photon measurements and enables beta discrimination.
The digital display features an analog bar graph, 2.5 digit digital readout,
low battery and freeze (peak hold) mode indicators, and an automatic backlight
function. User controls consist of an ON/OFF button and a MODE button. The
case is constructed of lightweight, high-strength materials and is sealed against
moisture. The RS-232 interface can be connected directly to a computer for use
with the Excel add-in for Windows (451EXL), enhancing the functionality of
the instrument. This software allows for data retrieval, user parameter selection
and provides a virtual instrument display with audible (requires sound card)
and visual alarm indication.

Typical energy dependence

451B typical energy dependence

1.2
1.1
1

Indicated/Actual

0.9

Side
Slide - Closed

0.8

Slide - Open

0.7
0.6
0.5
0.4
0.3
0.2
10

28

Ion Chamber Survey Meters

100

Effective (keV)

1000

10000

High sensitivity measurement


of rate and dose simultaneously
with the capability to record
peak rate
Auto-ranging and auto-zeroing
RS-232 communications
interface with optional
Windows-based Excel add-in for
data logging
Ergonomic, anti-fatigue handle
with replaceable grip, wrist
strap and tripod mount
Programmable flashing LCD
display and audible alarm
Easily-accessible battery door
(operated by two 9-volt alkaline
batteries) on the outside of the
bottom case
Available with dose equivalent
energy response (SI units)
Shoulder strap and handle that
can be easily decontaminated
(Nuclear power plant specific
unit)

451B

Ion Chamber Survey Meter with Beta Slide


Optional accessories

Specifications
Radiation detected

Beta above 100 keV, and Gamma above 7 keV

Operating ranges
0 to 5 mR/h or 0 to 50 Sv/h
0 to 50 mR/h or 0 to 500 Sv/h
0 to 500 mR/h or 0 to 5 mSv/h
0 to 5 R/h or 0 to 50 mSv/h
0 to 50 R/h or 0 to 500 mSv/h
Accuracy

Within 10 % of reading between 10 % and 100 % of full


scale indication on any range, exclusive of energy response.
Calibration source is 137Cs

451EXL 451 Assistant for Excel,


includes RS-232 interface cable
190HPS Single Unit Carrying Case
450UCS Check Source, 238Uranium,
0.064 Ci, impregnated 2 x 2 in
yellow card
62-103 Check Source, 137Cs, 10 Ci.
Flat disc, 1 inch diameter
Due to recent international airline
shipping policies/restrictions, radioactive
Check Source will not be shipped with
the main unit outside US.

Detector
Chamber

349 cc volume air ionization

Chamber wall

246 mg/cm2 thick phenolic

Chamber window

6.6 mg/cm2 mylar, protected by steel mesh, 46 cm2 detection


area

Beta slide

440 mg/cm2

451B-DE-SI

In order to achieve energy response consistent with


measurements of H*(10) as required by ICR4-47, aluminum
has been added to the back wall, 38 % of the side wall area,
and to the beta slide. With the Beta Shield open, the 451B can
measure skin dose at H*(0.07), and Deep Dose H*(10) with Beta
Shield closed

Controls

ON/OFF and MODE

Automatic features

Auto-zeroing, auto-ranging and auto-backlight

Response time

Range

Response

0 to 5 mR/h (0 to 50 Sv/h)

8s

0 to 50 mR/h (0 to 500 Sv/h)

2.5 s

0 to 500 mR/h (0 to 5 mSv/h)

2s

0 to 5 R/h (0 to 50 mSv/h)

2s

0 to 50 R/h (0 to 500 mSv/h)

2s

Display LCD analog/digital with backlight


Analog

100 element bar graph 6.4 cm long. Bar graph is divided into 5
major segments, each labeled with the appropriate value for the
range of the instrument

Digital

2.5 digit display is followed by a significant zero digit


depending on the operating range of the instrument. The units
of measurement are indicated on the display at all times. Digits
are 6.4 mm (0.25 in) high. Low battery and freeze indicators are
also provided on the display

Modes
Integrate mode

Operates continuously 30 seconds after the instrument has


been turned on. Integration is performed even if the instrument
is displaying in mR/h or R/h

Freeze mode

Will place a tick mark on the bar graph display to hold on


the peak displayed value. The unit will continue to read and
display current radiation values

Environmental
Power requirements

Two 9 V alkaline, 200 hours operation

Warm-up time

One minute

Temperature range

-20 C to 70 C (-4 F to 158 F)

Relative humidity

0 % to 100 %, @ 60 C

Geotropism

Less than 1 %

Dimensions (WxDxH)

10 cm x 20 cm x 15 cm (4 in x 8 in x 6 in)

Weight

1.11 kg (2.5 lb)

For full specifications please visit www.flukebiomedical.com/451B

Ion Chamber Survey Meters

29

451P

Pressurized R Ion Chamber Survey Meter


The auto-ranging 451P features a
pressurized ion chamber, providing
enhanced sensitivity (R resolution)
and improved energy response to
measure radiation rate and dose
from X-ray and gamma sources.
Originally designed to measure
leakage and scatter around diagnostic X-ray and radiation therapy
suites, the 451Ps site surveying
capabilities make it well-suited
for a wide range of end users,
including X-ray manufacturers,
government agencies, state inspectors, biomedical technicians and
maintenance technicians for airport
baggage scanners.
The ion chamber detector allows
for a fast response time to radiation from leakage, scatter beams
and pinholes. Additionally, the low-noise chamber bias supply provides for fast
background settling time.
The digital display features an analog bar graph, 2.5 digit digital readout,
low battery and freeze (peak hold) mode indicators, and an automatic backlight
function. User controls consist of an ON/OFF button and a MODE button. The
case is constructed of lightweight, high strength materials and is sealed against
moisture. The RS-232 interface can be connected directly to a computer for use
with the Excel add-in for Windows (451EXL), enhancing the functionality of the
instrument. This software allows for data retrieval, user-parameter selection
and provides a virtual instrument display with audible (requires sound card)
and visual alarm indication.
Typical energy dependence
16
Nitrogen gamma rays are 110 % to 120 % of indicated readings as determined
at the University of Lowell.
451P typical energy dependence
1.2
1.1
1

Indicated/Actual

0.9
Side

0.8

Face

0.7

Front

0.6
0.5
0.4
0.3
0.2
10

30

Ion Chamber Survey Meters

100

Effective (keV)

1000

10000

Key features
High sensitivity R measurements of rate and dose
simultaneously with the
capability to record peak rate
Ergonomic, anti-fatigue handle
with replaceable grip, wrist
strap and tripod mount
Easily-accessible battery door
(operated by two 9-volt alkaline
batteries) on the outside of the
bottom case
RS-232 communications
interface with optional
Windows-based Excel add-in
for data logging
Available with dose equivalent
energy response (SI units)
Shoulder strap and handle that can be easily
decontaminated (Nuclear
power plant specific unit)

451P

Pressurized R Ion Chamber Survey Meter


Optional accessories

Specifications
Radiation detected
Operating ranges

Accuracy

Beta above 1 MeV, Gamma and x-rays above 25 keV


0 to 500 R/h or 0 to 5 Sv/h
0 to 5 mR/h or 0 to 50 Sv/h
0 to 50 mR/h or 0 to 500 Sv/h
0 to 500 mR/h or 0 to 5 mSv/h
0 to 5 R/h or 0 to 50 mSv/h
Within 10% of reading between 10% and 100% of full
scale indication on any range, exclusive of energy response.
Calibration source is 137Cs

451EXL 451 Assistant for Excel,


includes RS-232 interface cable
190HPS Single Unit Carrying Case
62-103 Check Source, 137Cs, 10 Ci.
Flat disc, 1 inch diameter
Due to recent international airline
shipping policies/restrictions, radioactive
Check Source will not be shipped with
the main unit outside US.

Detector
Chamber

230 cc volume pressurized air ionization chamber to eight


atmospheres or 125 psi
Controls
ON/OFF and MODE
Automatic features
Auto-zeroing, auto-ranging, and auto-backlight
Response time
Step increase,
Time to reach 90 %
Analog response time from
background to
of final value
10% to 90% of reading for
400 R/h
4.8 s
a full scale step increase is
4 mR/h
3.3 s
dependent on operating range.
10 mR/h
4.3 s
Response time for a step
increase in radiation exposure 40 mR/h
4.5 s
rate from background:
100 mR/h
2.7 s
1 R/h
2s
4 R/h
2.7 s
This table shows time measured Range
10 % to 90 %
from 10% to 90% of final value 0 to 500 R/h (5 Sv/h)
5s
for a step increase or decrease
0 to 5 mR/h (50 Sv/h)
2s
in exposure rate such that a
0 to 50 mR/h (500 Sv/h)
1.8 s
range change does not occur.
These values are the response
0 to 500 mR/h (5 mSv/h)
1.8 s
times for the various ranges:
0 to 5 R/h (50 mSv/h)
1.8 s
Analog/Digital display LCD with backlight
Analog
100 element bar graph 6.4 cm (2.5 in) long. Bar graph is
divided into five major segments, each labeled with the
appropriate value for the range of the instrument
Digital
2.5 digit display is followed by a significant zero digit
depending on the operating range of the instrument. The
units of measurement are indicated on the display at all
times. Digits are 6.4 mm (0.25 in) high. Low battery and
freeze indicators are also provided on the display
Modes
Integrate mode
Operates continuously 30 seconds after the instrument
has been turned on. Integration is performed even if the
instrument is displaying in mR/h or R/h
Freeze mode
Will place a tick mark on the bar graph display to hold on
the peak displayed value. The unit will continue to read and
display current radiation values
Environmental
Power requirements
Two 9 V alkaline, 200 hours operation
Warm-up time
Less than two minutes for initial operation when the
instrument is in equilibrium with ambient temperature
Temperature range
-20 C to 50 C (-4 F to 122 F)
Relative humidity
0 to 100%
Geotropism
Negligible
Dimensions (WxDxH)
10 cm x 20 cm x 15 cm (4 in x 8 in x 6 in)
Weight
1.07 kg (2.4 lb)

For full specifications please visit www.flukebiomedical.com/451P

Ion Chamber Survey Meters

31

Fluke Biomedical CarePlans

Priority services to keep you up and running

Instrument CarePlans

Si

lv

er

ze

Biomedical Products

Br o

Look for the CarePlans logo in this catalog


for products with available extended service and support plans. Fluke Biomedicals
CarePlan packages offer comprehensive priority service and support to help you get the
most out of your test equipment investments.
Our CarePlan members enjoy priority bench
service, extended warranties, value pricing
on services, VIP technical support, expedited
return shipping, productivity consultation
services, educational training and more. Take
advantage of CarePlan priority service and
support and let us take care of you.

Choose the best plan for you

Biomedical Products

Instrument CarePlan

Gold

Silver

Turn-around time for repair

7 days

10 days

Turn-around time for calibration

3 days

3 days

First-on-bench priority service


Discounts on additional service requests

Operational upgrades
Accredited calibration to manufacturers specifications
Coverage options for up to 3 years
One-year extended warranty beyond your original factory
warranty. No-cost repair service

No cost repair service

No cost calibration
Coverage options for up to 3 years

32

Biomedical Products

Instrument CarePlan

CarePlans

Global Service and Calibration

World-class facilities. World-class service.


Calibrate the following

Fluke Biomedicals Global Calibration Lab is NVLAP Lab Code 200566-0


accredited, adheres to ISO 17025:2005, ANSI Z540, Mammography MQSA, and
CNSC, and is traceable to national and international standards.
Fluke Biomedical offers a variety of Service Options to meet your needs.
These options include Asset-Management for pools larger than 150 units,
On-Site calibration and Care Plan Options.
Asset-Management: Takes over your grueling task of instrument tracking
and allows you to use your time more productively. Proper protocols are strictly
followed, eliminating the problems with inspectors and audits that can result
when other less-qualified labs perform the calibrations.
On-Site Calibrations: Minimizes downtime and is scheduled when convenient for you. Calibrations are to OEM requirements, completed OEM upgrades,
and Automatic OEM updates.
Care Plan Options: Fluke Biomedicals Care Plan packages offer comprehensive priority service and support to help you get the most out of your test
equipment investments. As a member enjoy priority service, extended warranties, value pricing on service, VIP technical support, xpedited return shipping,
and more.

Calibration beam specifications


Radionuclide calibrations
Radionuclide sources

Minimum rate

Maximum rate

2000 Ci Cs-137

0.02 R/hr

850 R/hr

20 Ci Cs-137

0.1 mR/hr

4 R/hr

4 Ci Cs-137

0.5 mR/hr

1 R/hr

500 mCi Cs-137

0.04 mR/hr

150 mr/hr

1300 Ci Co-60

0.01 R/hr

450 R/hr

Collimated 2200 Ci Co-60

2575

3530

Area monitors
Barometers
Blood pressure simulators
Defibrillators/External pace
Maker analyzers
Densitometers
Diode detectors
Dosimeters
Electrical safety analyzers
Incubator analyzers
Ion chambers
IV pump analyzers
kVp meters
mAs meters
Electrical multimeters
Oscilloscopes
Patient simulators
Pressure meters/Parameter
testers
Radiation multimeters
Sensitometers
SpO2 simulators/Analyzers
Thermometers
Test lungs
Ultra sound analyzers
Velometers
Ventilators/Gas flow analyzers

Contact information
Service Center/Repair/Calibration US
Fluke Biomedical a division of Fluke
Electronics
6045 Cochran Road, Cleveland OH
44139-3303
Tel: 440-498-2564
Toll free: 800-850-4608 ext 2564
Email: globalcal@flukebiomedical.com
Service Center/Repair/Calibration
Europe
Fluke Biomedical Europe
Science Park Eindhoven 5110, 5692EC
Son, The Netherlands
Tel: +31 (40) 267 5435
Fax: +31 (40) 267 5436
Email: servicedesk@fluke.nl
www.flukebiomedical.com/service

Service and Calibration

33

Ordering information
Defibrillators
Impulse 6000D Defibrillator Analyzer
IMPULSE 6000D United States, 120 V
IMPULSE 6000D-01 Schuko
IMPULSE 6000D-02 United Kingdom
IMPULSE 6000D-03 Japan
IMPULSE 6000D-04 Australia
IMPULSE 6000D-05 India
IMPULSE 6000D-06 Brazil

QA-ES Series III Electrosurgery


Analyzers with test automation
TA-QA-ES MK III US
TA-QA-ES MK III Schuko
TA-QA-ES MK III UK
TA-QA-ES MK III Japan
TA-QA-ES MK III Australia
TA-QA-ES MK III Brazil
Non-wireless version are available with
and without test automation.

Infusion Pump Analyzers

Impulse 7000DP Defibrillator/


Transcutaneous Pacemaker Analyzer
IMPULSE 7000DP United States, 120 V
IMPULSE 7000DP-01 Schuko
IMPULSE 7000DP-02 United Kingdom
IMPULSE 7000DP-03 Japan
IMPULSE 7000DP-04 Australia
IMPULSE 7000DP-05 India
IMPULSE 7000DP-06 Brazil
Impulse 7000DP Defibrillator/
Transcutaneous Pacemaker Analyzer
with test automation
TA-IMP7KDP United States, 120 V
TA-IMP7KDP-01 Schuko
TA-IMP7KDP-02 United Kingdom
TA-IMP7KDP-03 Japan
TA-IMP7KDP-04 Australia
TA-IMP7KDP-05 India
TA-IMP7KDP-06 Brazil
Impulse 7000DP Defibrillator/
Transcutaneous Pacemaker Analyzer
with Impulse 7010 and test automation
TA-IMP7K/7010US United States, 120 V
TA-IMP7K/7010SHK Schuko
TA-IMP7K/7010UK United Kingdom
TA-IMP7K/7010JPN Japan
TA-IMP7K/7010AUS Australia
TA-IMP7K/7010BRA Brazil

Electrosurgery Analyzers
QA-ES Series III Electrosurgery
Analyzers

QA-ES MK III
QA-ES MK III 01 UK
QA-ES MK III 02 UK
QA-ES MK III 03 JAPAN
QA-ES MK III 04 Australia
QA-ES MK III 05 Brazil

34

Ordering Information

IDA-5 One-Channel Infusion Device


Analyzer
IDA-5/1 US120V United States, 120 V
IDA-5/1 AUS250V Australia, 250 V

IDA-5/1 DEN250V Denmark 250 V


IDA-5/1 SHK250V Shuko, 250 V
IDA-5/1 ISR250V Israel, 250 V
IDA-5/1 ITAL250V Italy, 250 V
IDA-5/1 IND250V India, 250 V
IDA-5/1 SWZ250V Switzerland, 250 V
IDA-5/1 UK250V, United Kingdom, 250V
IDA-5/1 BRAZ230V, Brazil, 230 V
IDA-5 Two-Channel Infusion Device
Analyzer
IDA-5/2 US120V, United States, 120 V
IDA-5/2 AUS250V, Australia, 250 V
IDA-5/2 DEN250V, Denmark, 250 V
IDA-5/2 SHK250V, Shuko, 250 V
IDA-5/2 ISR250V, Israel, 250 V
IDA-5/2 ITAL250V, Italy, 250 V
IDA-5/2 IND250V, India, 250 V
IDA-5/2 SWZ250V, Switzerland, 250 V
IDA-5/2 UK250V, United Kingdom, 250V
IDA-5/2 BRAZ230V, Brazil, 230 V
IDA-5 Four-Channel Infusion Device
Analyzer
IDA-5/4 US120V, US, 120 V
IDA-5/4 AUS250V, Australia, 250V
IDA-5/4 DEN250V, Denmark, 250V
IDA-5/4 SHK250V, Shuko, 250V
IDA-5/4 ISR250V, Israel, 250V
IDA-5/4 ITAL250V, Italy, 250V
IDA-5/4 IND250V, India, 250V
IDA-5/4 SWZ250V, Switzerland, 250V
IDA-5/4 UK250V, United Kingdom, 250V
IDA-5/4 BRAZ230V, Brazil, 230V
IDA-1S One-Channel Infusion Device
Analyzer
IDA-1S One-Channel Infusion Device
Analyzer

Electrical Safety
Analyzers
ESA609 Electrical Safety Analyzer
ESA609-US Electrical Safety Analyzer,
United States
ESA609-02-EUR Electrical Safety
Analyzer, Europe
ESA609-01-FR Electrical Safety Analyzer
France
ESA609-06-UK Electrical Safety
Analyzer, United Kingdom
ESA609-05-AUS Electrical Safety
Analyzer, Australia
ESA609-07-SWISS Electrical Safety
Analyzer, Switzerland
ESA609-03-ISR Electrical Safety
Analyzer, Israel
ESA609-11-BRAZIL Electrical Safety
Analyzer, Brazil 230 V
ESA609-12-INDIA Electrical Safety
Analyzer, India
ESA609-09-Japan Electrical Safety
Analyzer, Japan
ESA609-08-THAI Electrical Safety
Analyzer, Thailand 230 V
ESA609-US W/ADAPT, ESA609-US W/
ADAPT, Electrical Safety Analyzers, United
States
ESA612 Electrical Safety Analyzer
ESA612 United States, 115 V 20 A
ESA612-02 Europe, 230 V
ESA612-01 France, 230 V
ESA612-03 Israel, 230 V
ESA612-05 Australia, 230 V
ESA612-06 United Kingdom, 230 V
ESA612-07 Switzerland, 230 V
ESA612-08 Thailand, 230 V
ESA612-09 Japan, 100 V
ESA612-10 North America, 220 V
TA-ESA612-US United States, 115 V 20A
w/Test AutomationTA-ESA612-EUR Europe,
230 V w/Test Automation
TA-ESA612-FR France, 230 V w/Test
Automation
TA-ESA612-ISR Israel, 230 V w/Test
Automation
TA-ESA612-AUS Australia, 230 V
w/Test Automation
TA-ESA612-UK United Kingdom, 230V
w/Test Automation
TA-ESA612-SWI Switzerland, 230 V
w/Test Automation
TA-ESA612-THAI Thailand, 230 V
w/Test Automation
TA-ESA612-JAPAN Japan, 100 V
w/Test Automation
TA-ESA612-NA220V North America,
220 V, w/Test Automation

ESA615 Electrical Safety Analyzer


ESA615-US United States, 115 V
ESA620-02-EUR Europe, 230 V
ESA615-01-FR France/Belgium, 230 V
ESA615-03-ISR Israel, 230 V
ESA615-05-AUS Australia, 230 V
ESA615-06-UK United Kingdom, 230 V
ESA615-07-SWISS Switzerland, 230 V
ESA615-08-THAI Thailand, 230 V
ESA615-11-BRAZ Brazil, 230 V
ESA615-09-JAPAN Japan, 100 V
ESA615-12-INDIA India, 250V
ESA615-10-NA220V North America,
220V
TA-ESA615-USA ESA615 United States
115V w/Test Automation
TA-ESA615-EUR ESA615 Europe, 230V
w/Test Automation
TA-ESA615-FR ESA615 France/Belgium
230V w/Test Automation
TA-ESA615-ISR ESA615 Israel 230V
w/Test Automation
TA-ESA615-AUS ESA615 Australia
230V w/Test Automation
TA-ESA615-SWISS ESA615 Switzerland
230V w/Test Automation
TA-ESA615-UK ESA615United Kingdom
230V w/Test Automation
TA-ESA615-THAI ESA615 Thai 230V
w/Test Automation
TA-ESA615-BRAZ ESA615 Brazil 230V
w/Test Automation
TA-ESA615-JAPAN ESA615 Japan
100V w/Test Automation
TA-ESA615-12-INDIA ESA615 India
230V w/Test Automation
TA-ESA615-NA220V ESA615 North
America 220V w/Test Automation
ESA620 Electrical Safety Analyzer
ESA620 United States, 115 V, 20 A
ESA620-02 Europe, 230 V
ESA620-01 France, 230 V
ESA620-03 Israel, 230 V
ESA620-05 Australia, 230 V
ESA620-06 United Kingdom, 230 V
ESA620-07 Switzerland, 230 V
ESA620-08 Thailand, 230 V
ESA620-10 230VBRAZ Brazil, 230 V
TA-ESA620-USA ESA620 United States
115V 20A w/Test Automation
TA-ESA620-EUR ESA620 Europe,
230 V w/Test Automation
TA-ESA620-FR ESA620 France 230 V
w/Test Automation
TA-ESA620-ISR ESA620 Israel 230 V
w/Test Automation
TA-ESA620-AUS ESA620 Australia
230V w/Test Automation
TA-ESA620-SWI ESA620 Switzerland
230V w/Test Automation
TA-ESA620-UK ESA620 United
Kingdom 230V w/Test Automation

Vital Signs Simulators


ProSim 8 Vital Signs Simulators
ProSim 8
ProSim SPOT ProSim SpO2 Test Module
ProSim RAINBOW ProSim Rainbow
Sensor
ProSim 4 Vital Signs Simulators
ProSim 4
ProSim 3 Vital Signs Simulators
ProSim 3
ProSim 2 Vital Signs Simulators
ProSim 2

VT305
VT305 VT305 Gas Flow Analyzer
TA-VT305 VT305 Gas Flow Analyzer
with ANSUR BT Plug-In License

Neonatal Test
Equipment
Incubator/Radiant Warmer Analyzers
INCU II-BT Incubator Analyzer, Wireless
INCU II-NO BT Incubator Analyzer, NonWireless
DALE40 Phototherapy Radiometer
PS320 Fetal Simulator
MAXO2+AE Oxygen Analyzer

SPOT Light
SPOT Light SpO2 Tester

Gas Flow Analyzers


VTPLUS HF
VT+HF-US120 VT PLUS HF Gas Flow
Analyzer United States, 120 V
VT+HF/ACCULUNG-US VT PLUS HF
Gas Flow Analyzer/ACCU LUNG - United
States
VT+HF-AUS250V VT PLUS HF Gas Flow
Analyzer Australia, 250 V
VT+HF/ACCULUNG-AUS VT PLUS
HF Gas Flow Analyzer/ACCU LUNG Australia
VT+HF-SHK250V VT PLUS HF Gas Flow
Analyzer Schuko, 250 V
VT+HF/ACCULUNG-SHK VT PLUS HF
Gas Flow Analyzer/ACCU LUNG - Schuko
VT+HF-UK250V VT PLUS HF Gas Flow
Analyzer United Kingdom, 250 V
VT+HF/ACCULUNG-UK VT PLUS HF
Gas Flow Analyzer/ACCU LUNG - United
Kingdom
VT+HF-BRA250V VT PLUS HF Gas Flow
Analyzer Brazil, 250 V
VT+HF/ACCULUNG-BRAZ VT PLUS HF
Gas Flow Analyzer/ACCU LUNG - Brazil
VT Mobile
VTMOB/ENG Gas Flow Analyzer with
English overlay
VTMOB/BRAZ Gas Flow Analyzer with
Brazil overlay
VTMOB/CHI Gas Flow Analyzer with
Chinese overlay
VT MOBILE FRA Gas Flow Analyzer
with French overlay
VT MOBILE DEU Gas Flow Analyzer
with German overlay
VT MOBILE ITA Gas Flow Analyzer with
Italian overlay
VT MOBILE JPN Gas Flow Analyzer
with Japanese overlay
VT MOBILE SPAN Gas Flow Analyzer
with Spanish overlay

ScopeMeter Medical
Oscilloscopes
190M-2 Medical ScopeMeter Portable
Oscilloscope
190M-4 Medical ScopeMeter Portable
Oscilloscope

Radiation
Safety
990 Advanced
Survey Meter
451B Ion Chamber
Survey Meter with
Beta Slide
451B-RYR Ion Chamber Survey Meter
with Beta Slide and standard chamber
451B-DE-SI-RYR Ion Chamber
Survey Meter with Beta Slide and dose
equivalent chamber
451P Pressurized R Ion Chamber
Survey Meter
451P-RYR Pressurized R Ion Chamber
Survey Meter with standard chamber
451P-DE-SI-RYR Pressurized R
Ion Chamber Survey Meter with dose
equivalent chamber

Ordering Information

35

Contact information
Fluke Biomedical
6045 Cochran Road
Cleveland, OH 44139-3303 U.S.A.

Learn anytime, anywhere


To learn more, go to
www.flukebiomedical.com/advantagetraining

Connect with us
facebook.com/flukebiomedical
https://www.linkedin.com/
company/fluke-biomedical

Fluke Biomedical Europe


Science Park Eindhoven 5110
5692EC Son, The Netherlands
For more information,
contact us
In the U.S.A. (800) 850-4608 or
Fax (440) 349-2307
In Europe/M-East/Africa
+31 40 267 5435 or
Fax +31 40 267 5436
From other countries
+1 (440) 248-9300 or
Fax +1 (440) 349-2307
Email:
sales@flukebiomedical.com
Web access:
www.flukebiomedical.com

Service Center/Repair/
Calibration US
Fluke Biomedical
6045 Cochran Road
Cleveland OH 44139-3303
Tel: 440-498-2564
Toll free:
800-850-4608 ext 2564
Email:
globalcal@flukebiomedical.com
Service Center/Repair/
Calibration Europe
Fluke Biomedical Europe
Science Park Eindhoven 5110
5692EC Son, The Netherlands
Tel: +31 (40) 267 5435
Fax: +31 (40) 267 5436
Email: servicedesk@fluke.nl

@flukebiomedical

Your authorized Fluke Biomedical distributor

Instrument Technologies Company Limited

133 Arena Road, Freeport, Trinidad & Tobago, West Indies


Tel: (868) 673-6965/7752, Cell: 376-3286, Fax: (868) 673-4166
Sales & Marketing Department
Email: Admin@InstrumentTechnologies.com
Website: www.InstrumentTechnologies.com

Fluke Biomedical.
Trusted for the measurements that matter.
Fluke Biomedical
6045 Cochran Road
Cleveland, OH 44139-3303 U.S.A.
For more information, contact us at:
(800) 850-4608 or Fax (440) 349-2307
Email: sales@flukebiomedical.com
Web access: www.flukebiomedical.com
2016 Fluke Biomedical. Specifications subject
to change without notice.All OEM company trademarks
are implied. Printed in U.S.A. 3/2016 4123694e-en
Modification of this document is not permitted
without written permission from Fluke Corporation.

You might also like