You are on page 1of 3

) (6 )

375 ( )( AIR COOLING SECROW TYPE


) 3)( A&B&C -:
RATED LOAD AMPER) ) RLA
)COMP(A

330.8A

)COMP(B

204.2A

)COMP(C

330.8A

)22 ( )(6.5A
" .

.

. ).( CK1&CK2
.
((CK1 ) ( A+.) (8 .
((CK2 )+ . ( B+A) (14.

" ) .( NEC
" - : )(CK1
) ( MIN IMUM CIRCUIT AMPACITY ).( M.C.A

) -:
(NEC440-33
) " * + 1.25
( )RATED
.(LOAD AMPER R.L.A

-: ((CK1 -:
MCA= (1.25*330.8)+ +(8*6.5)= 465.5 AMP
.
") ) 0.6
"-

MCA/0.6) ) =465.5/0.6 = 776 A


-:
389A

= )).776/2CABLE

150mm
.REQ CABLE
2(3.5*150mm2)+70mm2
.

. DIS. SWITCH
= * (NEC430-110) .1.15
D.S = 1.15*(330.8+(8*6.5))=440A
STANDARD VALUE

" ) ( MOCP
)(CK1

) * +2.25 ( ).(NEC440-22A
MOCP= (2.25*330.8)+(8*6.5)= 796A
CK2 -:
MCA= 709A
MOCP=1039A


MOCP
700A
1000A

MCA
465.8A
709.3A


/ .
0591418898 /

CK1
CK2