Professional Documents
Culture Documents
Manual
Visit our website (www.autonics.com) to download user manual and communication manual.
User manual describes for specifications and function, and communication manual describes for RS485 communication
(Modbus RTU protocol) and parameter address map data.
Minimum requirements
System
256MB or more
Hard disk
VGA
Others
H-18
(A)
Photoelectric
Sensors
R
OUT 2
3
control output
Standard N
Heating & R
Cooling C
Power supply
SSR drive output (standard ON/OFF control, phase control, cycle control)
100-240VAC 50/60Hz
2
N
D
R
T
SP
S
M
W
H
L
Digit
Item
(F)
Rotary
Encoders
Standard
Standard
(G)
Connectors/
Sockets
(H)
Temperature
Controllers
Alarm output 1
Alarm output 1
(I)
SSRs / Power
Controllers
(J)
Counters
DIN W48H24mm
SP
DIN W72H72mm
DIN W96H48mm
DIN W48H96mm
DIN W96H96mm
9999 (4digit)
TK
(K)
Timers
(L)
Panel
Meters
(M)
Tacho /
Speed / Pulse
Meters
(N)
Display
Units
(O)
Sensor
Controllers
(P)
Switching
Mode Power
Supplies
(Q)
Stepper Motors
& Drivers
& Controllers
1: In case of TK4N, TK4SP, option output may be limited due to number of terminals.
2: S represents SSR drive output support models which SSRP function (standard ON/OFF control, cycle control, phase control) are
available. C represents selectable current and SSR drive output support models.
3: Select "R" or "C" type in case of using heating&cooling control and "N" type in case of using standard control.
4: Does not support in AC/DC voltage type model.
(R)
Graphic/
Logic
Panels
(S)
Field
Network
Devices
(D)
Proximity
Sensors
(E)
Pressure
Sensors
(B)
Fiber
Optic
Sensors
(C)
Door/Area
Sensors
Relay output
Size
Relay output
Option input/output
None
Select in case of standard control (Heating or Cooling)
(T)
Software
H-19
TK Series
Specifications
TK4N
TK4SP
TK4S
TK4M
TK4W
TK4H
TK4L
100-240VAC 50/60Hz
24VAC 50/60Hz, 24-48VDC
90 to 110% of rated voltage
Max. 6VA
Max. 8VA
Max. 8VA(24VAC 50/60Hz), Max. 5W(24-48VDC)
7 Segment (PV: red, SV: green), Other display part (green, yellow, red) LED method
4.57.2mm
7.014.0mm
9.520.0mm
8.517.0mm
7.014.6mm
11.022.0mm
3.55.8mm
5.010.0mm
7.515.0mm
6.012.0mm
6.012.0mm
7.014.0mm
JPt100, DPt100, DPt50, Cu100, Cu50, Nikel 120 (6 types)
K, J, E, T, L, N, U, R, S, B, C, G, PLII (13 types)
Voltage: 0-100mV, 0-5V, 1-5V, 0-10V (4 types) / Current: 0-20mA, 4-20mA (2 types)
1
At room temperature (235): (PV 0.3% or 1, select the higher one) 1digit
RTD
Out of room temperature range: (PV 0.5% or 2, select the higher one) 1digit
Display Thermocouple In case of TK4SP Series, 1 will be added.
accuracy
Analog
At room temperature (235): 0.3% F.S. 1digit Out of range of room temperature: 0.5% F.S. 1digit
CT input
5% F.S. 1digit
Relay
OUT1, OUT2: 250VAC 3A 1a
Control
SSR
11VDC2V 20mA Max.
output
Current
DC4-20mA or DC0-20mA selectable (load 500 Max.)
Alarm
AL1, AL2 Relay: 250VAC 3A 1a
Relay
TK4N AL2: 250VAC 0.5A 1a (Max.125VA), TK4SP has only AL1.
output
Transmission
DC4-20mA (load 500 Max., Accuracy: 0.3% F.S.)
Option
output
Communication RS485 communication output (Modbus RTU)
CT input
0.0-50.0A (primary heater current value measuring range) CT ratio = 1/1000 (except TK4SP)
Contact Input: ON - Max. 2k, OFF - Min. 90k
Option
Non-contact Input: ON - Residual votage max. 1.0V, OFF - Leakage current max. 0.1mA
input
Digital input
Outflow current: Approx. 0.5mA
TK4S/M-1EA (TK4S-D
-2EA, TK4SP-None), TK4N/H/W/L-2EA
Control Heating, cooling
ON/OFF, P, PI, PD, PID control
type
Heating&cooling
Hysteresis
Thermocouples / RTD: 1 to 100/ (0.1 to 100.0/) variable Analog: 1 to 100digit
Proportional band (P)
0.1 to 999.9/ (0.1 to 999.9%)
Integral time (I)
0 to 9999 sec.
Derivative time (D)
0 to 9999 sec.
Control period (T)
Relay output, SSR drive output: 0.1 to 120.0 sec., Current output or SSR drive output selectable: 1.0 to 120.0 sec.
Manual reset value
0.0 to 100.0%
Sampling period
50ms
Dielectric strength
2,000VAC 50/60Hz for 1min. (between power source terminal and input terminal)
Vibration
0.75mm amplitude at frequency of 5 to 55Hz (for 1min.) in each X, Y, Z direction for 2 hours
Mechanical
OUT1/2: Over 5,000,000 times, AL1/2: Over 20,000,000 times (TK4H/W/L: Over 5,000,000 times)
Relay
life cycle Electrical
OUT1/2: Over 200,000 times, AL1/2: Over 100,000 times (TK4H/W/L: Over 200,000 times)
Insulation resistance
Min. 100M (at 500VDC megger)
Noise resistance
2kV R-phase, S-phase the square wave noise (pulse width: 1us) by the noise simulator
Memory retention
Approx. 10 years (when using non-volatile semiconductor memory type)
Ambient
-10
to 50, storage: -20 to 60
Environ- temperature
ment
Ambient
35 to 85%RH, storage: 35 to 85%RH
humidity
Protection structure
IP65 (Front panel) TK4SP: IP50 (Front panel)
Double insulation or reinforced insulation
Insulation type
(Mark: , Dielectric strength between the measuring input part and the power part: 2kV)
Approval
Approx. 140g Approx. 130g Approx. 150g Approx. 210g
Approx. 294g
2
Weight
Approx. 211g (Approx. 141g)
(Approx. 70g) (Approx. 85g) (Approx. 105g) (Approx. 140g)
(Approx. 198g)
1: At room temperature (235)
Thermocouple K, J, T, N, E type, below -100 / Thermocouple L, U, PL type, RTD Cu50, DPt50
: (PV 0.3% or 2, select the higher one) 1digit
Thermocouple C, G, R, S type, below 200: (PV 0.3% or 3, select the higher one) 1digit
Thermocouple B type, below 400: There is no accuracy standards.
Out of room temperature range
RTD Cu50, DPt50: (PV 0.5% or 3, select the higher one) 1digit
Thermocouple R, S, B, C, G type: (PV 0.5% or 5, select the higher one) 1digit
Others, Below -100: Within 5
In case of TK4SP Series, 1 will be added to the degree standard.
2: The weight includes packaging. The weight in parentheses is for unit only.
Environment resistance is rated at no freezing or condensation.
Series
AC voltage
AC/DC voltage
Allowable voltage range
AC voltage
Power
consumption AC/DC voltage
Display method
Character PV (WH)
size
SV (WH)
RTD
Input
Thermocouple
type
Analog
Power
supply
H-20
Please check the polarity when connecting temperature sensor or analog input.
Standard model has shaded terminals only.
Operation mode of heating&cooling OUT 2 relay output model is heating or cooling, OUT 2 is available as alarm output 3.
(except TK4N Series).
Operation mode of heating&cooling OUT 2 current output model is heating or cooling, OUT 2 is available as transmission
output 2.
TK4N
SSR
DI-2
DI-1
Digital Input
Non-contact, contact input
AL2 OUT:
250VAC 0.5A 1a
RESISTIVE LOAD
OUT2/AL1 OUT:
OUT1:
250VAC 3A 1a
250VAC 3A 1a
RESISTIVE LOAD RESISTIVE LOAD
2
3
OUT1:
Relay
250VAC 3A 1a
RESISTIVE LOAD
DI-2
Transfer
Output
DC4-20mA
4
5
mA
14
RS485 (A+)
15
RS485 (B-)
16
Current
Transformer
0.0-50.0A
SOURCE
100-240VAC 50/60Hz 8VA
24VAC 50/60Hz 8VA
24-48VDC 5W
DI-2
Communication
Output
17
CT
mA
TC
18
mA
B'
12
A
RTD
SENSOR
1
2
3
RTD
TC
AL1 OUT:
250VAC 3A 1a
RESISTIVE LOAD
AL2 OUT:
250VAC 3A 1a
RESISTIVE LOAD
11
10
AL1:
Relay
250VAC 3A 1a
RESISTIVE LOAD
19
10
20
11
21
12
DI-1
13
23
14
OUT1:
Relay
250VAC 3A 1a
RESISTIVE LOAD
24
15
25
16
26
17
27
18
B'
RTD TC
SENSOR
5
6
7
SSR
Current
3
4
14
3
4
14
mA
mA
DC0/4-20mA
Load 500 Max.
SSR
Current
9
6
5
4
9
6
DC4-20mA
Current
Transformer
0.0-50.0A
mA
mA
DC0/4-20mA
Load 500Max.
(O)
Sensor
Controllers
(P)
Switching
Mode Power
Supplies
(Q)
Stepper Motors
& Drivers
& Controllers
(R)
Graphic/
Logic
Panels
(S)
Field
Network
Devices
6
7
Current
11VDC2V
20mA Max.
mA
(M)
Tacho /
Speed / Pulse
Meters
(N)
Display
Units
DC0/4-20mA
Load 500Max.
(K)
Timers
(L)
Panel
Meters
11VDC2V
20mA Max.
(I)
SSRs / Power
Controllers
(J)
Counters
DC0/4-20mA
Load 500 Max.
13
(G)
Connectors/
Sockets
(H)
Temperature
Controllers
mA
DC0/4-20mA
Load 500 Max.
SSR
mA Transfer Output
Communication Output
CT
11VDC2V
20mA Max.
11VDC2V
20mA Max.
RS485 (A+)
22
(F)
Rotary
Encoders
mA
Digital Input
Non-contact, contact input
DI-1
RS485 (B-)
DC0/4-20mA
Load 500 Max.
11VDC2V
20mA Max.
SOURCE
100-240VAC 50/60Hz 8VA
24VAC 50/60Hz 8VA
24-48VDC 5W
OUT2:
Relay
250VAC 3A 1a
RESISTIVE LOAD
OUT1
13
OUT2
B'
SOURCE
100-240VAC 50/60Hz 8VA
24VAC 50/60Hz 8VA
24-48VDC 5W
10
OUT2:
Relay
250VAC 3A 1a
RESISTIVE LOAD
11VDC2V
20mA Max.
SENSOR
OUT1:
Relay
250VAC 3A 1a
RESISTIVE LOAD
11
TK4SP
TK4M
AL2 OUT:
250VAC 3A 1a
RESISTIVE LOAD
OUT2
DI-1
AL1 OUT:
250VAC 3A 1a
RESISTIVE LOAD
OUT1
DI-1
Digital Input
Non-contact,
contact input
OUT2
Digital Input
Non-contact,
contact input
13
OUT1
SOURCE
100-240VAC
50/60Hz 6VA
TK4S
(C)
Door/Area
Sensors
(E)
Pressure
Sensors
Current
11VDC2V
20mA Max.
OUT2
RTD
OUT1
DI-2
DI-1
TC
(B)
Fiber
Optic
Sensors
(D)
Proximity
Sensors
Communication
Output
Current Transformer
0.0-50.0A
CT
mA
SENSOR
RS485 (A+)
RS485 (B-)
Transfer Output
DC4-20mA
(A)
Photoelectric
Sensors
4
5
11VDC2V
20mA Max.
6
7
(T)
Software
mA
DC0/4-20mA
Load 500 Max.
mA
DC0/4-20mA
Load 500 Max.
H-21
TK Series
Connections
Please check the polarity when connecting temperature sensor or analog input.
Standard model has shaded terminals only.
Operation mode of heating&cooling OUT2 relay output model is heating or cooling, OUT2 is available as alarm output 3.
(except TK4N Series).
Operation mode of heating&cooling OUT2 current output model is heating or cooling, OUT2 is available as transmission
output 2.
1
2
14
15
AL1 OUT:
250VAC 3A 1a
RESISTIVE LOAD
7
8
9
10
+
SOURCE
100-240VAC 50/60Hz 8VA
24VAC 50/60Hz 8VA
24-48VDC 5W
DI-2
17
AL2 OUT:
250VAC 3A 1a
RESISTIVE LOAD
DI-1
DI-2
18
OUT2:
Relay
250VAC 3A 1a
RESISTIVE LOAD
19
OUT1:
Relay
250VAC 3A 1a
RESISTIVE LOAD
21
11
23
12
24
mA
RS485 (B )
Transfer Out
DC4-20mA
Communication Output
20
22
SSR
RS485 (A )
OUT1
DI-1
16
CT
Current
Transformer
0.0-50.0A
A
B
B'
Current
mA
10
mA
10
DC0/4-20mA
Load 500 Max.
11VDC2V
20mA Max.
RTD TC
SENSOR
11VDC2V
20mA Max.
OUT2
Digital Input
Non-contact, contact input
mA
8
DC0/4-20mA
Load 500 Max.
Dimensions
TK4N
(unit: mm)
TK4S
48
94.8
24
21.8
TK4SP
TK4M
72
64.5
1.7
44.8
67.5
72.2
48
1.7
45
48
64.5
TK4W
TK4H
64.5
91.5
96
48
64.5
1.5
1.5
44.7
96
H-22
48
96
Panel cut-out
64.5
(A)
Photoelectric
Sensors
1.5
(B)
Fiber
Optic
Sensors
D
B
(C)
Door/Area
Sensors
C
(unit: mm)
91.5
Model
TK4N
TK4S
TK4SP
TK4M
TK4H
TK4W
TK4L
Size A
Min. 55
Min. 65
Min. 65
Min. 90
Min. 65
Min. 115
Min. 115
Min. 37
Min. 65
Min. 65
Min. 90
Min. 115
Min. 65
Min. 115
45
45+00.6
45+00.6
68+00.7
45+00.6
92+00.8
92+00.8
(D)
Proximity
Sensors
D
+0.6
0
22.2
45+00.6
45+00.6
68+00.7
92+00.8
45+00.6
92+00.8
+0.3
0
(E)
Pressure
Sensors
(F)
Rotary
Encoders
(G)
Connectors/
Sockets
Bracket
TK4S, TK4SP Series
36
44.9
22
3.5
36.3
28.8
45.2
48.6
32.4
26.4
3.3
46
15
21
55
(H)
Temperature
Controllers
(I)
SSRs / Power
Controllers
45
31
20
(J)
Counters
37.5
40.5
42
TK4M/W/H/L Series
48.6
16
TK4N Series
(K)
Timers
11.6
12
(L)
Panel
Meters
7.9
23.9
10
(M)
Tacho /
Speed / Pulse
Meters
56
70
68.5
41.5
(O)
Sensor
Controllers
(P)
Switching
Mode Power
Supplies
22
(Q)
Stepper Motors
& Drivers
& Controllers
13
18
TK4N COVER is accessory.
(N)
Display
Units
48.4
21.8
44.6
64
9.8
22.5
13
(S)
Field
Network
Devices
94
(T)
Software
86
86
91.5
91.5
47.2
13
(R)
Graphic/
Logic
Panels
H-23
TK Series
Product Mounting
TK4N (4824mm) Series
(+) driver
Insert the unit into a panel, fasten
the bolt with a (+) driver.
Unit Description
Other Series
(-)driver
Insert the unit into a panel, fasten
the bracket by pushing with tools
with a (-) driver.
(-) driver
H-24
(A)
Photoelectric
Sensors
Communication converter
SCM-38
SCM-US48
(B)
Fiber
Optic
Sensors
SCM-US
(C)
Door/Area
Sensors
(D)
Proximity
Sensors
(E)
Pressure
Sensors
(F)
Rotary
Encoders
3.8
K (Black)
L (White)
150
10.5
26.5
(unit: mm)
10
23.3
7
(G)
Connectors/
Sockets
F=50Hz
Ta=25
100
10
0.1
10
100
(K)
Timers
1000
(L)
Panel
Meters
CSTC-E200LN
10
10
4.5
K (Black)
L (White)
13.5
40.8
150
(unit: mm)
13
100
Ta=25
10
0.1
0.01
0.001
0.1
10
100
1000
(N)
Display
Units
(O)
Sensor
Controllers
(Q)
Stepper Motors
& Drivers
& Controllers
Do not supply primary current in case that CT output is open. High voltage will be generated in CT output.
The current for above two CTs is 50A same but inner hole sizes are different. Please use this for your environment.
(R)
Graphic/
Logic
Panels
(S)
Field
Network
Devices
DS22/DA22- T
(M)
Tacho /
Speed / Pulse
Meters
(P)
Switching
Mode Power
Supplies
DS16- T
(I)
SSRs / Power
Controllers
(J)
Counters
0.01
0.001
0.1
37.1
(H)
Temperature
Controllers
(T)
Software
DS40/DA40- T
DS60/DA60- T
Connect RS485 communication input type display unit (DS/DA-T Series) and RS485 communication output model of TK Series,
the display unit displays present value of the device without PC/PLC.
H-25
TK Series
Parameter Group
Run mode
Press any key among
once.
, ,
PASS 1
When PW is
valid
SV
Set the
set value
2 sec.
PASS
PASS
When PW is
valid
PARU3
PAR1
SV will be automatically
saved after 5 sec.
1.5 sec.
PAR2
key.
key replaces
key.
Hold the
key for 1.5 sec while in setting mode to move to other
parameter group.
Hold the
Press
key at the last parameter of each parameter, it moves to that
parameter name. You can move to other groups.
If there is no additional key operation within 30 sec after entering into setting
mode, it will be automatically returned to RUN mode and previous set value
will be remained.
The shaded parameters (
H-26
3 sec.
3 sec.
3 sec.
H-MV
C-MV
Heating MV
Monitoring
PAR3
(B)
Fiber
Optic
Sensors
(C)
Door/Area
Sensors
Cooliing MV
Monitoring
PAR4
(D)
Proximity
Sensors
(E)
Pressure
Sensors
PAR5
(F)
Rotary
Encoders
Multi SV [MtSV]
(G)
Connectors/
Sockets
1.5 sec.
1.5 sec.
SV low-limit [L-SV]
SV high-limit [H-SV]
(H)
Temperature
Controllers
(I)
SSRs / Power
Controllers
(J)
Counters
(K)
Timers
(L)
Panel
Meters
(M)
Tacho /
Speed / Pulse
Meters
(N)
Display
Units
(O)
Sensor
Controllers
(P)
Switching
Mode Power
Supplies
(Q)
Stepper Motors
& Drivers
& Controllers
(R)
Graphic/
Logic
Panels
(S)
Field
Network
Devices
(T)
Software
3 sec.
3 sec.
3 sec.
H-27
TK Series
Parameter 1 Group
3 sec.
PASS
Run mode
2 sec.
S 1
PASS
When PW
is unequal
0001
When PW is valid.
Parameter 1 group
Parameter 2 group
Parameter 3 group
PAR1
PAR2
PAR3
R-5
Multi SV number
SV-N
Heater current monitoring
CT-A
AL!L
AL!H
AL@L
AL@H
AL#L
AL#H
SV-0
SV-1 set value
SV-1
SV-2 set value
SV-2
SV-3 set value
SV-3
RUN
SV-0
STOP
SV-1
SV-2
SV-3
Display SV0 through SV3, depending on the preset number of multi SVs [MtSV]
H-28
)0
1550
1550
1550
1550
1550
1550
Displayed only with option output models that support alarm output 3.
(Active/inactive conditions ard the same as alarm output 1 with the exception for
HBA)
0000
0000
Setting range: L-SV to H-SV, unit (/)
The number of multi SVs [SV0 to SV3] set at Multi SV [MtSV] are displayed.
0000
0000
(A)
Photoelectric
Sensors
Parameter 3 group
Parameter 4 group
PAR2
PAR3
PAR4
Auto-tuning RUN/STOP
AT
(B)
Fiber
Optic
Sensors
(C)
Door/Area
Sensors
(D)
Proximity
Sensors
(E)
Pressure
Sensors
OFF
ON
(F)
Rotary
Encoders
H-P
Cooling proportional band
C-P
Heating integral time
H-I
Cooling integral time
C-1
Heating derivative time
H-D
Cooling derivative time
C-D
Dead_overlap band
DB
Manual reset
REST
Heating hysteresis
hHYS
Heating OFF offset
hOST
Cooling hysteresis
cHYS
Cooling OFF offset
cOST
S
S
S
S
S
S
S
S
S
S
01)0
01)0
0000
0000
0000
05)0
002
000
002
000
(H)
Temperature
Controllers
0000
0000
(G)
Connectors/
Sockets
(I)
SSRs / Power
Controllers
(K)
Timers
(L)
Panel
Meters
(M)
Tacho /
Speed / Pulse
Meters
(N)
Display
Units
Setting range:
P/P, P/ONOFF, ONOFF/P control: -significant proportion to 0.0 to + significant proportion
ONOFF/ONOFF control: -999 to 999 digit (Temp. H), -199.9 to 999.9 digit (Temp. L),
-99.9 to 99.9% F.S. (Analog)
Displayed only when control output operation mode [O-FT] is set to heating and cooling [H-C].
Setting range: 000.0 to 100.0%
Displayed only under proportional control.
Does not display if control output operation mode [O-FT] is set to heating and cooling [H-C]).
(O)
Sensor
Controllers
(P)
Switching
Mode Power
Supplies
(Q)
Stepper Motors
& Drivers
& Controllers
(R)
Graphic/
Logic
Panels
(J)
Counters
(S)
Field
Network
Devices
H-29
(T)
Software
TK Series
MV low limit
L-MV
MV high limit
H-MV
RAMP-up change rate
RAMU
RAMD
RAMP unit
rUNT
00)0
10)0
0000
0000
MIN
HOUR
SEC
Parameter 3 Group
1: S : Press any key among , ,
After entering setting mode, press
key anytime for 3 sec. to return to Run mode.
After entering setting mode, press
key anytime for 1.5 sec. to go to the concerned group name.
If you press the
key after changing the setting value of the parameter the setting value will be stored.
Shaded parameters are for standard-level users, the others are for high-level users.
(You can set the user level in parameter 5 group)
This parameter might not be displayed depending on other parameter settings.
Parameter 3 group
Parameter 4 group
Parameter 5 group
PAR3
PAR4
PAR5
Input type
IN-T
Sensor temperature unit
UNIT
L-RG
H-RG
Decimal point
DOT
Low-limit scale value
L-SC
High-limit scale value
H-SC
Display unit
dUNT
H-30
KCaH
KCaL
?C
?F
AMA2
Displayed only when input type [IN-T] is set to temperature sensor
input.
0)00
1)00
)0
00)0
10)0
?/?
OFF
?C
?F
IN-B
Input digital filter
MAvF
SV low-limit
L-SV
SV high-limit
H-SV
O-FT
Control type
C-MD
Auto-tuning mode
AtT
(A)
Photoelectric
Sensors
000
(B)
Fiber
Optic
Sensors
(C)
Door/Area
Sensors
00)1
-200
(D)
Proximity
Sensors
(E)
Pressure
Sensors
1350
HEAT
H-C
PID
pP
COOL
HEAT
ONOF
pON
(F)
Rotary
Encoders
Standard type
COOL
(G)
Connectors/
Sockets
(H)
Temperature
Controllers
Standard control
OnP
OnON
(I)
SSRs / Power
Controllers
(J)
Counters
TUN1
TUN2
Displayed only when temperature control type [C-MD] is set to PID control.
(K)
Timers
OUT1
O!SR
O!MA
OUT2
O@MA
H-T
Cooling control time
C-T
CURR
STND
SSR
CYCL
PHAS
0-20
CURR
SSR
0-20
(O)
Sensor
Controllers
(P)
Switching
Mode Power
Supplies
(Q)
Stepper Motors
& Drivers
& Controllers
(R)
Graphic/
Logic
Panels
02)0
02)0
(M)
Tacho /
Speed / Pulse
Meters
(N)
Display
Units
4-20
4-20
(L)
Panel
Meters
(S)
Field
Network
Devices
(T)
Software
H-31
TK Series
Parameter 4 Group
1: S : Press any key among , ,
After entering setting mode, press
key anytime for 3 sec. to return to Run mode.
After entering setting mode, press
key anytime for 1.5 sec. to go to the concerned group name.
If you press the
key after changing the set value of the parameter the set value will be stored.
Shaded parameters are for standard-level users, the others are for high-level users.
(You can set the user level in parameter 5 group)
This parameter might not be displayed depending on other parameter settings.
Parameter 4 group
Parameter 5 group
PAR4
PAR5
AL-1
AL!T
Parameter 1 group
PAR1
DVCC
]]DV
OFF
AL-A
AL-B
AL-F
Displayed only if alarm output 1's operating mode [AL-1] is not set to OFF.
Alarm output 1 hysteresis
S
A!HY
Alarm 1 N.O./N.C.
A!N
Alarm 1 ON delay time
A!ON
Alarm 1 OFF delay time
A!OF
AL-2
AL@T
A@HY
Alarm 2 N.O./N.C.
A@N
Alarm 2 ON delay time
A@ON
Alarm 2 OFF delay time
A@OF
H-32
001
NO
NC
0000
0000
]]DV
]DVC
DVCC
AL-A
AL-B
AL-F
001
NO
NC
0000
Setting range
: 0000 to 3600 sec.
0000
Setting range
: 0000 to 3600 sec.
AL-3
AL#T
Alarm output 3 hysteresis
A#HY
Alarm 3 N.O./N.C.
A#N
Alarm 3 ON delay time
A#ON
Alarm 3 OFF delay time
A#OF
LBA time
LBaT
LBA band
LBaB
(A)
Photoelectric
Sensors
OFF
DVCC
AL-A
HBA
AL-F
Displayed only if alarm output 3's operating mode [AL-3] is
not set to OFF.
001
NO
0000
(C)
Door/Area
Sensors
(D)
Proximity
Sensors
(E)
Pressure
Sensors
(F)
Rotary
Encoders
NC
Setting range
: 0000 to 3600 sec.
0000
Setting range
: 0000 to 3600 sec.
0000
Setting range
: 0000 to 9999 sec.
002
(B)
Fiber
Optic
Sensors
(G)
Connectors/
Sockets
(H)
Temperature
Controllers
(I)
SSRs / Power
Controllers
(J)
Counters
(K)
Timers
Setting range
: 0000 to 999 (H)
000.0 to 999.9 (L)
000.0 to 99.99 (Analog)//%
(L)
Panel
Meters
(M)
Tacho /
Speed / Pulse
Meters
Previous models
Analog trans. output 1 mode
S
AoM1
FsL1
FsH1
AoM2
FsL2
FsH2
PV
SV
C-MV
H-MV
-200
1350
PV
SV
C-MV
H-MV
-200
1350
AO-M
FS-L
FS-H
PV
SV
C-MV
H-MV
-200
1350
(N)
Display
Units
(O)
Sensor
Controllers
(P)
Switching
Mode Power
Supplies
(Q)
Stepper Motors
& Drivers
& Controllers
(R)
Graphic/
Logic
Panels
(S)
Field
Network
Devices
(T)
Software
Displayed
only for
transmission
output
model.
H-33
TK Series
Comm. address
ADRS
Comm. speed
BPS
Comm. parity bit
PRTY
Comm. stop bit
STP
01
96
192
NONE
EVEN
RSwT
Comm. write
COMW
Setting range: 01 to 99
20
48
ODD
EnA
DIsA
Parameter 5 Group
Parameter 5 group
Parameter 1 group
Parameter 2 group
PAR1
PAR2
PAR5
Multi SV
MtSV
Digital Input Key
DI-K
DI-1
DI-2
ItMV
PrMV
Sensor error, MV
ErMV
Control stop, MV
StMV
H-34
STOP
AlRE
AT
OFF
STOP
OFF
Press
+
keys for 3 sec.
and it executes the set function.
MtSV
Displays all models except TK4N, TK4SP.
(except TK4S-D4
)
OFF
AUTO
STOP
MtSV
PrMV
00)0
00)0
00)0
StAL
User level
USER
SV setting lock
LcSV
Parameter 1 group lock
LcP1
Parameter 2 group lock
LcP2
Parameter 3 group lock
LcP3
Parameter 4 group lock
LcP4
Parameter 5 group lock
LcP5
Password setting
PWD
CONT
OFF
STND
HIGH
OFF
ON
(A)
Photoelectric
Sensors
(B)
Fiber
Optic
Sensors
(C)
Door/Area
Sensors
(D)
Proximity
Sensors
(E)
Pressure
Sensors
OFF
ON
OFF
ON
OFF
(F)
Rotary
Encoders
(G)
Connectors/
Sockets
(H)
Temperature
Controllers
ON
(I)
SSRs / Power
Controllers
OFF
ON
OFF
ON
0000
(J)
Counters
(K)
Timers
(L)
Panel
Meters
(M)
Tacho /
Speed / Pulse
Meters
SV Setting
(N)
Display
Units
Press
or
key to move
the desired number
(1 5).
(O)
Sensor
Controllers
(P)
Switching
Mode Power
Supplies
(Q)
Stepper Motors
& Drivers
& Controllers
(R)
Graphic/
Logic
Panels
Press
key to save the
value and it controls with this
set value.
(even though there is no key
input for over 3 sec., it saves
automatically.)
(S)
Field
Network
Devices
(T)
Software
Parameter Reset
TK Series
Input Type And Range
Decimal point
Display
Input range ()
Input range ()
KCaH
-200 to 1350
-328 to 2463
KCaL
-199.9 to 999.9
-199.9 to 999.9
JIcH
-200 to 800
-328 to 1472
0.1
JIcL
-199.9 to 800.0
-199.9 to 999.9
ECrH
-200 to 800
-328 to 1472
ECrL
-199.9 to 800.0
-199.9 to 999.9
TCcH
-200 to 400
-328 to 752
0.1
TCcL
-199.9 to 400.0
-199.9 to 752.0
B (PR)
B PR
0 to 1800
32 to 3272
R (PR)
R PR
0 to 1750
32 to 3182
S (PR)
S PR
0 to 1750
32 to 3182
N (NN)
N NN
-200 to 1300
-328 to 2372
C TT
0 to 2300
32 to 4172
G TT
0 to 2300
32 to 4172
LIcH
-200 to 900
-328 to 1652
0.1
LIcL
-199.9 to 900.0
-199.9 to 999.9
UCcH
-200 to 400
-328 to 752
0.1
UCcL
-199.9 to 400.0
-199.9 to 752.0
Platinel
PLII
0 to 1390
32 to 2534
Cu 50
0.1
CU 5
-199.9 to 200.0
-199.9 to 392.0
Cu 100
0.1
CU10
-199.9 to 200.0
-199.9 to 392.0
JPtH
-200 to 650
-328 to 1202
0.1
JPtL
-199.9 to 650.0
-199.9 to 999.9
0.1
DPT5
-199.9 to 600.0
-199.9 to 999.9
DTtH
-200 to 650
-328 to 1202
0.1
DPtL
-199.9 to 650.0
-199.9 to 999.9
NI12
-80 to 200
-112 to 392
Input type
K (CA)
0.1
J (IC)
E (CR)
0.1
T (CC)
Thermocouple
C (TT)
G (TT)
L (IC)
U (CC)
JPt 100
RTD
DPt 50
DPt 100
Nickel 120
Voltage
Analog
Current
0-10V
AV1
0-5V
AV2
1-5V
AV3
0-100mV
AMV1
0-20mA
AMA1
4-20mA
AMA2
-1999 to 9999
(Display point will be changed according to
decimal point position)
H-36
4. Run mode
(A)
Photoelectric
Sensors
SV setting [SV]
Parameter
SV
Factory default
Parameter
(B)
Fiber
Optic
Sensors
Factory default
PASS
0001
(C)
Door/Area
Sensors
Factory default
Parameter
Factory default
Parameter
Factory default
R-S
RUN
AL!H
1550
AL#H
1550
SV-N
SV-0
AL@L
1550
SV-0
0000
CT-A
)0
AL@H
1550
SV-1
0000
AL!L
1550
AL#L
1550
SV-2
0000
Parameter
SV-3
Factory default
0000
(E)
Pressure
Sensors
(F)
Rotary
Encoders
Factory default
Parameter
Factory default
0000
Parameter
Factory default
OFF
H-D
hOST
H-P
01)0
C-D
0000
cHYS
C-P
01)0
DB
0000
cOST
H-1
0000
REST
05)0
L-MV
`0)0
C-1
0000
hHYS
002
H-MV
10)0
000
Parameter
Factory default
RAMU
000
002
RAMD
000
000
rUNT
MIN
Factory default
Parameter
Factory default
IN-T
KCaH
H-SC
10)0
UNIT
><?C
dUNT
>?/O
(I)
SSRs / Power
Controllers
Parameter
HEAT (standard)
Factory default
O!SR
STND
O!MA
4-20
PID (standard)
OUT2
CURR
O@MA
4-20
L-RG
0)00
IN-B
0000
H-RG
1)00
MAvF
00)1
DOT
)0
L-SV
-200
AtT
TUN1
H-T
L-SC
00)0
H-SV
1350
OUT1
CURR
C-T
Factory default
Parameter
Factory default
0000
C-MD
Factory default
Parameter
AL-1
DVCC
A@N
NO
LBaT
AL!T
AL-A
A@ON
0000
LBaB
A!HY
001
A@OF
0000
AoM1 (AO-M )
A!N
NO
AL-3
OFF
A!ON
0000
AL#T
AL-A
Parameter
(L)
Panel
Meters
02)0 (relay)
00@0 (SSR)
(M)
Tacho /
Speed / Pulse
Meters
Factory default
BPS
96
PRTY
NONE
PV
STP
RSWT
20
COMW
EnA
002 (003 )
1
A!OF
0000
A#HY
001
AoM2
PV
AL-2
]]DV
A#N
NO
FsL2
-200
AL@T
AL-A
A#ON
0000
FsH2
1350
A@HY
001
A#OF
0000
ADRS
01
Factory default
Parameter
Factory default
Parameter
Factory default
(N)
Display
Units
(O)
Sensor
Controllers
(P)
Switching
Mode Power
Supplies
(Q)
Stepper Motors
& Drivers
& Controllers
(R)
Graphic/
Logic
Panels
(J)
Counters
(K)
Timers
(G)
Connectors/
Sockets
(H)
Temperature
Controllers
(D)
Proximity
Sensors
Parameter
Factory default
MtSV
PrMV
00)0
LcSV
OFF
LcPS
OFF
DI-K
STOP
ErMV
00)0
LcP1
OFF
PWD
0000
DI-1
OFF
StMV
00)0
LcP2
OFF
DI-2
OFF
StAL
CONT
LcP3
OFF
ItMV
AUTO
USER
STND
LcP4
OFF
(S)
Field
Network
Devices
(T)
Software
H-37
TK Series
Alarm
Alarm operation
Mode
OFF
DVCC
Name
Alarm operation
Description
No alarm output
H
OFF
Deviation
high-limit
alarm
SV
100
OFF
ON
PV
110
ON
Deviation
low-limit
alarm
ON
PV
90
]]DV
OFF
PV
90
SV
100
ON
SV
100
SV
100
OFF
PV
110
]DV [
ON
Deviation
high/low-limit
alarm
PV
90
OFF
SV
100
ON
PV
120
CDV]
OFF
Deviation
high/low-limit
reserve alarm
ON
PV
90
SV
100
OFF
PV
120
OFF
PVCC
Absolute
value high
limit alarm
PV
90
]]PV
SV
100
Absolute-value Alarm:
Set as 90
ON
Absolute
value low
limit alarm
OFF
ON
PV
90
SV
100
ON
PV
110
Absolute-value Alarm:
Set as 110
OFF
Absolute-value Alarm:
Set as 90
ON
SV
100
OFF
PV
110
Absolute-value Alarm:
Set as 110
LBA
SBA
HBA
H: Alarm
SV
100
Alarm option
Mode
Name
AL-A
Standard alarm
Description
AL-B
Alarm latch
AL-C
First alarm condition is ignored and from second alarm condition, standard alarm operates.
Standby sequence 1 When power is supplied and it is an alarm condition, this first alarm condition is ignored and from the
second alarm condition, standard alarm operates.
AL-D
If it is an alarm condition, it operates both alarm latch and standby sequence. When power is supplied
Alarm latch and
and it is an alarm condition, this first alarm condition is ignored and from the second alarm condition,
standby sequence 1
alarm latch operates.
AL-E
First alarm condition is ignored and from second alarm condition, standard alarm operates.
Standby sequence 2 When re-applied standby sequence and if it is alarm condition, alarm output does not turn ON.
After clearing alarm condition, standard alarm operates.
AL-F
Basic operation is same as alarm latch and standby sequence 1. It operates not only by power ON/OFF,
Alarm latch and
but also alarm set value, or alarm option changing. When re-applied standby sequence and if it is alarm
standby sequence 2 condition, alarm output does not turn ON.
After clearing alarm condition, alarm latch operates.
If it is an alarm condition, alarm output is ON. If it is a clear alarm condition, alarm output is OFF.
If it is an alarm condition, alarm output is ON and maintains ON status.
Condition of re-applied standby sequence for standby sequence 1, alarm latch and standby sequence 1: Power ON
Condition of re-applied standby sequence for standby sequence 2, alarm latch and standby sequence 2: Power ON, changing set
temperature, alarm temperature [AL1, AL2] or alarm operation [AL-1, AL-2], switching STOP mode to RUN mode.
H-38
(A)
Photoelectric
Sensors
Parameter mask
(B)
Fiber
Optic
Sensors
This function is able to hide unnecessary parameters to user environment or less frequently used parameters in
parameter setting group. You can set this in the comprehensive device management program (DAQMaster).
Though masked parameters are not displayed in parameter setting group, the parameter set values are applied. For
more information, refer to the DAQMaster user manual.
(C)
Door/Area
Sensors
Visit our web site (www.autonics.com) to download the DAQMaster program and the user manual.
E.g.)The above is masking auto tuning [AT], cooling proportional band [C-P], cooling integral time [C-1], cooling
derivative time [C-D] parameters in parameter 2 group.
Before applying mask
PAR2
AT
H-P
C-P
H-I
C-I
H-D
C-D
After applying mask
PAR2
H-P
H-I
(D)
Proximity
Sensors
(E)
Pressure
Sensors
H-D
(F)
Rotary
Encoders
PAR1
AL!L
(J)
Counters
AL!H
SV-0
hHYS
cHYS
IN-B
A!HY
(L)
Panel
Meters
A@HY
(M)
Tacho /
Speed / Pulse
Meters
(N)
Display
Units
(O)
Sensor
Controllers
(P)
Switching
Mode Power
Supplies
(Q)
Stepper Motors
& Drivers
& Controllers
Descriptions
Auto tuning end
Auto tuning run
Parameter
AT
(I)
SSRs / Power
Controllers
PAR5
Setting group
PAR2
(H)
Temperature
Controllers
(K)
Timers
PARU
Set value
OFF
ON
(G)
Connectors/
Sockets
Setting range
OFF/ ON
Factory default
OFF
(R)
Graphic/
Logic
Panels
Unit
-
Manual interruption or a sensor disconnection error when auto-tuning is in progress restores the PID time constant to the
value used prior to the auto-tuning session.
Auto-tuning continues to run even if the temperature reading exceeds or falls below the input range.
When auto-turning is in progress, parameters can only be referenced and not altered.
Auto-tuning is not available in manual control.
H-39
(S)
Field
Network
Devices
(T)
Software
TK Series
Control output operation mode [O-FT]
Control output modes for general temperature control include heating, cooling, and heating and cooling.
Heating control and cooling control are mutually opposing operations with inverse outputs.
The PID time constant varies based on the controlled objects during PID control.
Control output
(MV)
100%
Control output
(MV)
100%
Heating control
(Heating)
0%
Cooling control
(Cooling)
PAR3
O-FT
0%
PV
PV
Standard model
HEAT/ COOL
HEAT
H-C
Cooling load
Temperature
drop
Temperature
rise
Temperature sensor
Input (feedback)
Heating load
Cooling
Temperature control
controller Heating
control
For heating and cooling control, OUT1 control output is dedicated to heating control and
OUT2 control output to cooling control.
In case of selecting the Models with current control output, both current and SSR drive outputs are available.
You can therefore choose the right output type depending on application environments.
- OUT1: Selects OUT1 control output.
- OUT2: Selects OUT2 control output.
Setting group
PAR3
H-40
Parameter
OUT1
OUT2
Setting range
Factory default
Unit
SSR/ CURR
SSR
(A)
Photoelectric
Sensors
It is for parameter setting and monitoring via external devices (PC, PLC, etc.).
Interface
(B)
Fiber
Optic
Sensors
Comm. protocol
Modbus RTU (character = 11-bit fixed) Comm. speed
2400, 4800, 9600, 19200, 38400 bps
Connection type
RS485
Comm. response wait time 5 to 99 ms
Application standard Compliance with EIA RS485
Start bit
1-bit (fixed)
Max. connection
31 units (address: 01 to 99)
Data bit
8-bit (fixed)
Synchronous method Asynchronous
Parity bit
None, Odd, Even
Comm. method
Two-wire half duplex
Stop bit
1-bit, 2-bit
Comm. distance
Max. 800m
It is not allowed to set overlapping communication address at the same communication line.
Use twisted pair wire for RS485 communication.
Terminating resistance
(100 to 120)
RS485
B(-)
A(+)
B(-)
ON
(D)
Proximity
Sensors
(E)
Pressure
Sensors
Comm.
converter
Computer
(C)
Door/Area
Sensors
OFF
A(+) B(-)
A(+) B(-)
A(+) B(-)
RS485
DEVICE
#1
RS485
DEVICE
#2
RS485
DEVICE
#30
(F)
Rotary
Encoders
RS485
DEVICE
#31
(G)
Connectors/
Sockets
(H)
Temperature
Controllers
(I)
SSRs / Power
Controllers
A(+)
It is recommended to use Autonics communication converter; SCM-US48I (USB to RS485 converter, sold separately),
SCM-38I (RS232C to RS485 converter, sold separately), SCM-US (USB to Serial converter, sold separately).
Please use twisted pair wire for RS485 communication.
(K)
Timers
Proper Usage
Simple "Error" diagnosis
When the load (Heater etc) is not operated
Please check operation of the OUT indicator located in
front panel of the unit.
If the OUT indicator does not operate, please check the
parameter of all programmed mode.
If OUT indicator is operating, please check the output
(Relay, SSR drive voltage) after separating output line
from the unit.
(J)
Counters
(L)
Panel
Meters
(M)
Tacho /
Speed / Pulse
Meters
(N)
Display
Units
(O)
Sensor
Controllers
(P)
Switching
Mode Power
Supplies
(Q)
Stepper Motors
& Drivers
& Controllers
(R)
Graphic/
Logic
Panels
(S)
Field
Network
Devices
(T)
Software
Indoor
Altitude: Under 2,000m
Pollution degree 2
Installation category