A. INTRODUCTION
This preliminary proposal document is specially prepared for PT. PERTAMINA
(Persero) Arun for the repair and corrosion protection to existing angular and roof
tank LPG Propane in Aceh Indonesia using Fiber Reinforced Polymer (FRP) and
Kansai Protective Coating.
The scope of this document shall highlight the proposal, the technical data
sheets of FRP and BMJP project reference.

PT. PERTAMINA (PERSERO) ARUN LNG STORAGE & REGASIFICATION STATION

B. SUMMARY OF EXISTING CONDITIONS TANK NO. 4

CONDITION EXSISTING OF SHELL TANK

OUTSIDE OF ANGULAR TANK ALREADY CORROSION


PT. PERTAMINA (PERSERO) ARUN LNG STORAGE & REGASIFICATION STATION

SHELL AND FLOOR FOUNDATION OF TANK ALREADY CHIPPED THE PAINT

INSIDE ANGULAR AND BASE PALTE OF TANK ALREADY CORROSION

PT. PERTAMINA (PERSERO) ARUN LNG STORAGE & REGASIFICATION STATION

C. PROPOSAL FOR REPAIR AND CORROSION PROTECTION TO EXISTING


ANGULAR AND ROOF TANK LPG PROPANE
The proposal for repair and corrosion protection required to the severely
damaged angular and roof tank is provided as a general guideline at this stage
of the project. A detailed proposal will be provided in accordance to the results
from investigation.
Following the list of defects and damages, the repair and upgrading approach to
address the list of problems will be as follows:a) INSIDE AND OUTSIDE ANGULAR TANK
1. Surface Preparation with hand tool (St2) and blasting (Sa2) for cleaning
angular tank from rust.
2. If there is a part angular of tank the surface uneven so given epoxy putty
as patch material.
3. After that, coating primary with Esco NB thickness 100 m.
4. Installation FRP 2 layer thickness 2000 m with overstate 50cm from
angular of tank to up toward shell tank and equal toward base plate.
5. Then, finish coating with Gel Coat / Coating High Built thickness 200 m.
b) ROOF TANK
1. Surface preparation with hand tool (St2) for cleaning existing paint and
corrosion with rust remover if needed.
2. After surface preparation, coating with Esco NB thickness 100 m for
corrosion protection.
3. Next, gel coat / coating HB thickness 200 m.
4. Finish coating with Retan 6000 (Polyurethane) thickness 150 m.

PT. PERTAMINA (PERSERO) ARUN LNG STORAGE & REGASIFICATION STATION

THE CONCEPT OF REPAIR AND CORROSION PROTECTION


INSIDE AND OUTSIDE ANGULAR OF TANK LPG PROPANE

PT. PERTAMINA (PERSERO) ARUN LNG STORAGE & REGASIFICATION STATION

PT. PERTAMINA (PERSERO) ARUN LNG STORAGE & REGASIFICATION STATION

THE CONCEPT OF REPAIR AND CORROSION PROTECTION


ROOF TANK LPG PROPANE

PT. PERTAMINA (PERSERO) ARUN LNG STORAGE & REGASIFICATION STATION

BMJP PROJECT REFERENCE


ON SIMILAR PROJECT

PT. PERTAMINA (PERSERO) ARUN LNG STORAGE & REGASIFICATION STATION

PT PERTAMINA PLUMPANG
DATE OF COMPLETION: 2015

VIEW OF TANKI TEST T.101D

PT. PERTAMINA (PERSERO) ARUN LNG STORAGE & REGASIFICATION STATION

PT PERTAMINA (Persero) RU VI BALONGAN


DATE OF COMPLETION: MARET 2011

PT. PERTAMINA (PERSERO) ARUN LNG STORAGE & REGASIFICATION STATION

PT PERTAMINA MOR V CAMPLONG, MADURA


DATE OF COMPLETION: NOVEMBER 2015

PT. PERTAMINA (PERSERO) ARUN LNG STORAGE & REGASIFICATION STATION

TECHNICAL DATA SHEET

PT. PERTAMINA (PERSERO) ARUN LNG STORAGE & REGASIFICATION STATION

You might also like