24-52 - AC ESSENTIAL DISTRIBUTION

** ON A/C ALL

24-52 - AC ESSENTIAL DISTRIBUTION


24-52-00 - AC ESSENTIAL DISTRIBUTION
24-52-00 PB 001 CONF 00 - AC ESSENTIAL
DISTRIBUTION - DESCRIPTION AND OPERATION
1. General
The AC essential distribution network corresponds to the busbars 9XP (AC ESS BUS) and 4XP (AC ESS BUS
SHED) and their associated sub-busbars.
** ON A/C 001-002
POST SB 24-5024 for A/C 003-003, 006-006
EMB SB 24-5024 for A/C 001-002
(Ref. Fig. AC Essential Distribution (General) - Block Diagram SHEET 1)

Print Date: October 31, 2016


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 1 of 38

Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-52 - AC ESSENTIAL DISTRIBUTION

24-22-00

AC BUS 1-1

24-51-00

1XP1

1QA3

1QA2

MAIN
FUEL PUMP 3

10QA2

MAIN
FUEL PUMP 2

4XP

1XC

AC ESS BUS SHED

10QA3

15XH

16XH

401XP

3XCA

CSM/G
GCU
1XE

115VAC
2XE
EMER GLC
3XCB

8XE

12XH

CSM/G

3XC

24-35-00

STATIC
INVERTER
24-28-00

901XP
3XB

AC ESS BUS

1XB

9XP

21XH

905XPB

1XH

2XC

26VAC

24-22-00

AC BUS 2-4

2XP4

931XPB

9XH 3XH

24-51-00

F_MM_245200_0_AAG0_01_00

Figure 24-52-00-11150-00-K / SHEET 1/1 - AC Essential Distribution (General) - Block Diagram


** ON A/C 001-002 | EMB SB 24-5024 for A/C 001-002 | POST SB 24-5024 for A/C 003-003, 006-006
** ON A/C 003-050
PRE SB 24-5024 for A/C 003-003, 006-006
(Ref. Fig. AC Essential Distribution (General) - Block Diagram SHEET 1)
Print Date: October 31, 2016
AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 2 of 38

Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-52 - AC ESSENTIAL DISTRIBUTION

24-22-00

AC BUS 1-1

1XP1

24-51-00

1QA3

1QA2
AC ESS BUS SHED

10QA3

MAIN
FUEL PUMP 3

10QA2

MAIN
FUEL PUMP 2

4XP

15XH

16XH

401XP

CSM/G
GCU
1XE

CSM/G

115VAC
2XE
EMER GLC

8XE

3XC

24-35-00

STATIC
INVERTER
24-28-00

901XP
3XB
AC ESS BUS

9XP

1XB
21XH

905XPB

1XH
26VAC

931XPA

9XH 3XH

24-22-00

AC BUS 2-4

2XP4

24-51-00

F_MM_245200_0_AAB0_01_00

Figure 24-52-00-11150-00-D / SHEET 1/1 - AC Essential Distribution (General) - Block Diagram


** ON A/C 003-050 | PRE SB 24-5024 for A/C 003-003, 006-006
** ON A/C ALL
Print Date: October 31, 2016
AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 3 of 38

Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-52 - AC ESSENTIAL DISTRIBUTION

2. Component Location
(Ref. Fig. AC Essential Distribution - Component Location SHEET 1)

Print Date: October 31, 2016


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 4 of 38

Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-52 - AC ESSENTIAL DISTRIBUTION

FR20
FR17
FR11
FR1

A
740VU

3XH

F_MM_245200_0_ADM0_01_00

Figure 24-52-00-12250-00-A / SHEET 1/1 - AC Essential Distribution - Component Location


** ON A/C ALL
Print Date: October 31, 2016
AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 5 of 38

Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-52 - AC ESSENTIAL DISTRIBUTION

FIN

FUNCTIONAL DESIGNATION

PANEL

ZO
NE

3XH
A/XFMR-115/26VAC, ESS
3. System Description
The AC essential distribution network can be supplied:
by the main distribution network,
by the CSM/G in emergency configuration (Ref. AMM D/O 24-24-00-00) ,
by the static inverter (Ref. AMM D/O 24-28-00-00) .
A. The Main Distribution Network

ACCESS
DOOR

121

ATA REF

24-52-51

(Ref. 24-22-22)
either by the AC BUS 1-1 (1XP1),
** ON A/C 001-002
POST SB 24-5024 for A/C 003-003, 006-006
EMB SB 24-5024 for A/C 001-002
(Ref. Fig. AC Essential Distribution (Normal Configuration) - Block Diagram SHEET 1)

24-22-00

AC BUS 1-1

1XP1

24-51-00

1QA3

1QA2

MAIN
FUEL PUMP 3

10QA2

MAIN
FUEL PUMP 2

4XP

1XC

AC ESS BUS SHED

10QA3

15XH

16XH

401XP

3XCA

CSM/G
GCU
1XE

115VAC
2XE
EMER GLC
3XCB

8XE

12XH

CSM/G

3XC

24-35-00

STATIC
INVERTER
24-28-00

901XP
3XB

AC ESS BUS

1XB

9XP

21XH

905XPB

1XH

2XC

26VAC

931XPB

9XH 3XH

24-22-00

AC BUS 2-4

2XP4

24-51-00

F_MM_245200_0_AGG0_01_00

Print Date: October 31, 2016


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 6 of 38

Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-52 - AC ESSENTIAL DISTRIBUTION

Figure 24-52-00-13550-00-K / SHEET 1/1 - AC Essential


Distribution (Normal Configuration) - Block Diagram
** ON A/C 001-002 | EMB SB 24-5024 for A/C 001-002
| POST SB 24-5024 for A/C 003-003, 006-006
** ON A/C 003-050
PRE SB 24-5024 for A/C 003-003, 006-006
(Ref. Fig. AC Essential Distribution (Normal Configuration) - Block Diagram SHEET 1)

24-22-00

AC BUS 1-1

1XP1

24-51-00

1QA3

1QA2
AC ESS BUS SHED

10QA3

MAIN
FUEL PUMP 3

10QA2

MAIN
FUEL PUMP 2

4XP

15XH

16XH

401XP

CSM/G
GCU
1XE

CSM/G

115VAC
2XE
EMER GLC

8XE

3XC

24-35-00

STATIC
INVERTER
24-28-00

901XP
3XB
AC ESS BUS

9XP

1XB
21XH

905XPB

1XH
26VAC

931XPA

9XH 3XH

24-22-00

AC BUS 2-4

2XP4

24-51-00

F_MM_245200_0_AGB0_01_00

Figure 24-52-00-13550-00-D / SHEET 1/1 - AC Essential


Distribution (Normal Configuration) - Block Diagram
** ON A/C 003-050 | PRE SB 24-5024 for A/C 003-003, 006-006
** ON A/C ALL

Print Date: October 31, 2016


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 7 of 38

Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-52 - AC ESSENTIAL DISTRIBUTION

or by the AC BUS 2-4 (2XP4) in case of loss of power from AC BUS 1-1
(Ref. AMM D/O 24-25-00-00) .
B. The Constant Speed Motor/Generator (CSM/G) in Emergency Configuration
(Ref. AMM D/O 24-24-00-00)
loss of AC 1-1 and AC 2-4 (including loss of the main electrical networks),
loss of the four engines when slats are retracted.
** ON A/C 001-002
POST SB 24-5024 for A/C 003-003, 006-006
EMB SB 24-5024 for A/C 001-002
(Ref. Fig. AC Essential Distribution (Emergency Configuration) - CSM/G Supplied by the Engine
Pump SHEET 1)

1XP1

AC BUS 1-1

24-22-00

24-51-00

1QA3

1QA2

MAIN
FUEL PUMP 3

10QA2

MAIN
FUEL PUMP 2

4XP

1XC

AC ESS BUS SHED

10QA3

15XH

16XH

401XP

3XCA

CSM/G
CCU
1XE

115VAC
2XE
EMER GLC
3XCB

CSM/G
8XE

12XH

3XC

STATIC
INVERTER
24-28-00

24-35-00

901XP
3XB

AC ESS BUS

1XB

9XP

21XH

905XPB

1XH

2XC

26VAC

24-22-00

AC BUS 2-4

2XP4

931XPB

9XH 3XH

24-51-00

F_MM_245200_0_AJG0_01_00

Figure 24-52-00-13800-00-K / SHEET 1/1 - AC Essential Distribution


(Emergency Configuration) - CSM/G Supplied by the Engine Pump
** ON A/C 001-002 | EMB SB 24-5024 for A/C 001-002
| POST SB 24-5024 for A/C 003-003, 006-006
** ON A/C 003-050
Print Date: October 31, 2016
AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 8 of 38

Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-52 - AC ESSENTIAL DISTRIBUTION

PRE SB 24-5024 for A/C 003-003, 006-006


(Ref. Fig. AC Essential Distribution (Emergency Configuration) - CSM/G Supplied by the Engine
Pump SHEET 1)

AC BUS 1-1

24-22-00

1XP1

24-51-00

1QA3

1QA2
AC ESS BUS SHED

10QA3

MAIN
FUEL PUMP 3

10QA2

MAIN
FUEL PUMP 2

4XP

15XH

16XH

401XP

CSM/G
CCU
1XE

CSM/G

115VAC
2XE
EMER GLC

8XE

3XC

24-35-00

STATIC
INVERTER
24-28-00

901XP
3XB
AC ESS BUS

9XP

1XB
21XH

905XPB

1XH
26VAC

931XPA

9XH 3XH

24-22-00

AC BUS 2-4

2XP4

24-51-00

F_MM_245200_0_AJB0_01_00

Figure 24-52-00-13800-00-D / SHEET 1/1 - AC Essential Distribution


(Emergency Configuration) - CSM/G Supplied by the Engine Pump
** ON A/C 003-050 | PRE SB 24-5024 for A/C 003-003, 006-006
** ON A/C 001-002
POST SB 24-5024 for A/C 003-003, 006-006
EMB SB 24-5024 for A/C 001-002
(Ref. Fig. AC Essential Distribution (Emergency Configuration) - CSM/G Supplied by the RAT
Pump SHEET 1)

Print Date: October 31, 2016


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 9 of 38

Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-52 - AC ESSENTIAL DISTRIBUTION

24-22-00

AC BUS 1-1

24-51-00

1XP1

1QA3

1QA2

MAIN
FUEL PUMP 3

10QA2

MAIN
FUEL PUMP 2

4XP

1XC

AC ESS BUS SHED

10QA3

15XH

16XH

401XP

3XCA

CSM/G
GCU
1XE

CSM/G

115VAC
2XE
EMER GLC
3XCB

8XE

24-35-00

12XH

3XC

STATIC
INVERTER
24-28-00

901XP
3XB

AC ESS BUS

1XB

9XP

21XH

1XH

2XC

26VAC

24-22-00

AC BUS 2-4

2XP4

905XPB

931XPB

9XH 3XH

24-51-00

F_MM_245200_0_ALG0_01_00

Figure 24-52-00-13850-00-K / SHEET 1/1 - AC Essential Distribution


(Emergency Configuration) - CSM/G Supplied by the RAT Pump
** ON A/C 001-002 | EMB SB 24-5024 for A/C 001-002
| POST SB 24-5024 for A/C 003-003, 006-006
** ON A/C 003-050
PRE SB 24-5024 for A/C 003-003, 006-006
(Ref. Fig. AC Essential Distribution (Emergency Configuration) - CSM/G Supplied by the RAT
Pump SHEET 1)

Print Date: October 31, 2016


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 10 of 38

Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-52 - AC ESSENTIAL DISTRIBUTION

24-22-00

AC BUS 1-1

1XP1

24-51-00

1QA3

1QA2
AC ESS BUS SHED

10QA3

MAIN
FUEL PUMP 3

10QA2

MAIN
FUEL PUMP 2

4XP

15XH

16XH

401XP

CSM/G
GCU
1XE

CSM/G

115VAC
2XE
EMER GLC

8XE

3XC

24-35-00

STATIC
INVERTER
24-28-00

901XP
3XB
AC ESS BUS

9XP

1XB
21XH

1XH
26VAC

905XPB

931XPA

9XH 3XH

24-22-00

AC BUS 2-4

2XP4

24-51-00

F_MM_245200_0_ALB0_01_00

Figure 24-52-00-13850-00-D / SHEET 1/1 - AC Essential Distribution


(Emergency Configuration) - CSM/G Supplied by the RAT Pump
** ON A/C 003-050 | PRE SB 24-5024 for A/C 003-003, 006-006
** ON A/C ALL

Print Date: October 31, 2016


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 11 of 38

Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-52 - AC ESSENTIAL DISTRIBUTION

C. The Static Inverter


(Ref. AMM D/O 24-28-00-00)
** ON A/C 001-002
POST SB 24-5024 for A/C 003-003, 006-006
EMB SB 24-5024 for A/C 001-002
(Ref. Fig. AC Essential Distribution (Emergency Configuration) - Static Inverter Configuration SHEET 1)

Print Date: October 31, 2016


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 12 of 38

Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-52 - AC ESSENTIAL DISTRIBUTION

AC BUS 1-1

24-22-00

1XP1

24-51-00
10QA3

MAIN
FUEL PUMP 3

1QA2

10QA2

MAIN
FUEL PUMP 2

4XP

1XC

AC ESS BUS SHED

1QA3

15XH

16XH

401XP

3XCA

CSM/G
GCU
1XE

12XH

8XE

115VAC
2XE
EMER GLC
3XCB

CSM/G

3XC

24-35-00

STATIC
INVERTER
24-28-00

901XP
3XB
AC ESS BUS

1XB

9XP

21XH

905XPB

1XH

2XC

26VAC

24-22-00

AC BUS 2-4

2XP4

931XPB

9XH 3XH

24-51-00

F_MM_245200_0_ANG0_01_00

Figure 24-52-00-14050-00-K / SHEET 1/1 - AC Essential Distribution


(Emergency Configuration) - Static Inverter Configuration
** ON A/C 001-002 | EMB SB 24-5024 for A/C 001-002 | POST SB 24-5024 for A/C 003-003, 006-006
** ON A/C 003-050
PRE SB 24-5024 for A/C 003-003, 006-006
(Ref. Fig. AC Essential Distribution (Emergency Configuration) - Static Inverter Configuration SHEET 1)
Print Date: October 31, 2016
AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 13 of 38

Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-52 - AC ESSENTIAL DISTRIBUTION

AC BUS 1-1

24-22-00

1XP1

24-51-00

1QA3

1QA2
AC ESS BUS SHED

10QA3

MAIN
FUEL PUMP 3

10QA2

MAIN
FUEL PUMP 2

4XP

15XH

16XH

401XP

CSM/G
GCU
1XE

CSM/G

115VAC
2XE
EMER GLC

8XE

3XC

24-35-00

STATIC
INVERTER
24-28-00

901XP
3XB
AC ESS BUS

9XP

1XB
21XH

1XH
26VAC

905XPB

931XPA

9XH 3XH

24-22-00

AC BUS 2-4

2XP4

24-51-00

F_MM_245200_0_ANB0_01_00

Figure 24-52-00-14050-00-D / SHEET 1/1 - AC Essential Distribution


(Emergency Configuration) - Static Inverter Configuration
** ON A/C 003-050 | PRE SB 24-5024 for A/C 003-003, 006-006
** ON A/C ALL
Print Date: October 31, 2016
AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 14 of 38

Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-52 - AC ESSENTIAL DISTRIBUTION

(1)

In emergency configuration:

as long as the CSM/G is not connected to the essential network (CSM/G starting phase),
when the CSM/G is no more available (slats extended with Ram Air Turbine (RAT) extended).
(2)
On the ground with only the batteries available
** ON A/C 001-002
POST SB 24-5024 for A/C 003-003, 006-006
EMB SB 24-5024 for A/C 001-002
(Ref. Fig. AC Essential Distribution - Static Inverter Operation in Ground Configuration SHEET 1)

Print Date: October 31, 2016


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 15 of 38

Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-52 - AC ESSENTIAL DISTRIBUTION

AC BUS 1-1

24-22-00

1XP1

24-51-00
10QA3

MAIN
FUEL PUMP 3

1QA2

10QA2

MAIN
FUEL PUMP 2

4XP

1XC

AC ESS BUS SHED

1QA3

15XH

16XH

401XP

3XCA

CSM/G
GCU
1XE

12XH

8XE

115VAC
2XE
EMER GLC
3XCB

CSM/G

3XC

24-35-00

STATIC
INVERTER
24-28-00

901XP
3XB
AC ESS BUS

1XB

9XP

21XH

1XH

2XC

26VAC

24-22-00

AC BUS 2-4

2XP4

905XPB

931XPB

9XH 3XH

24-51-00

F_MM_245200_0_AZG0_01_00

Figure 24-52-00-14550-00-K / SHEET 1/1 - AC Essential


Distribution - Static Inverter Operation in Ground Configuration
** ON A/C 001-002 | EMB SB 24-5024 for A/C 001-002 | POST SB 24-5024 for A/C 003-003, 006-006
** ON A/C 003-050
PRE SB 24-5024 for A/C 003-003, 006-006
(Ref. Fig. AC Essential Distribution - Static Inverter Operation in Ground Configuration SHEET 1)
Print Date: October 31, 2016
AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 16 of 38

Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-52 - AC ESSENTIAL DISTRIBUTION

24-22-00

AC BUS 1-1

1XP1

24-51-00

1QA3

1QA2
AC ESS BUS SHED

10QA3

MAIN
FUEL PUMP 3

10QA2

MAIN
FUEL PUMP 2

4XP

15XH

16XH

401XP

CSM/G
GCU
1XE

CSM/G

115VAC
2XE
EMER GLC

8XE

3XC

24-35-00

STATIC
INVERTER
24-28-00

901XP
3XB
AC ESS BUS

9XP

1XB
21XH

1XH
26VAC

905XPB

931XPA

9XH 3XH

24-22-00

AC BUS 2-4

2XP4

24-51-00

F_MM_245200_0_AZB0_01_00

Figure 24-52-00-14550-00-D / SHEET 1/1 - AC Essential


Distribution - Static Inverter Operation in Ground Configuration
** ON A/C 003-050 | PRE SB 24-5024 for A/C 003-003, 006-006
** ON A/C ALL
Print Date: October 31, 2016
AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 17 of 38

Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-52 - AC ESSENTIAL DISTRIBUTION

When the batteries are the only power source available on the ground and the BAT1 and BAT2
pushbutton switches are pushed, the battery voltage is higher than 23 VDC (line contactors closed).
D. AC ESS BUS (9XP) Network
** ON A/C 003-050
PRE SB 24-5024 for A/C 003-003, 006-006
The AC essential busbar (9XP) supplies three-phase 115 VAC/400 Hz power directly to sub-busbar 901XP.
The AC essential busbar (9XP) supplies single-phase 115 VAC/400 Hz power:
To sub-busbar 931XPA (26 VAC/400 Hz) through the 115/26 VAC transformer (3XH)
To sub-busbar 905XPB through relay 1XH. Sub-busbar 905XPB is shed in emergency configuration in
flight.
** ON A/C 001-002
POST SB 24-5024 for A/C 003-003, 006-006
EMB SB 24-5024 for A/C 001-002
The AC essential busbar (9XP) supplies three-phase 115 VAC/400 Hz power directly to sub-busbar 901XP.
The AC essential busbar (9XP) supplies single-phase 115 VAC/400 Hz power:
To sub-busbar 931XPB (26 VAC/400 Hz) through the 115/26 VAC transformer (3XH)
To sub-busbar 905XPB through relay 1XH. Sub-busbar 905XPB is shed in emergency configuration in
flight.
** ON A/C ALL
E. AC ESS BUS SHED (4XP) Network
The AC ESS BUS SHED (4XP) supplies three phase 115 VAC/400 Hz power:
through the relay 16XH, to the sub-busbar 401XP,
NOTE: This sub-busbar is automatically shed in emergency configuration when the CSM/G is supplied by
the RAT pump or when the static inverter operates.
** ON A/C 001-002
POST SB 24-5024 for A/C 003-003, 006-006
EMB SB 24-5024 for A/C 001-002
(Ref. Fig. AC Essential Distribution (Emergency Configuration) - CSM/G Supplied by the RAT
Pump SHEET 1)
** ON A/C 003-050
PRE SB 24-5024 for A/C 003-003, 006-006
(Ref. Fig. AC Essential Distribution (Emergency Configuration) - CSM/G Supplied by the RAT
Pump SHEET 1)
** ON A/C 001-002
POST SB 24-5024 for A/C 003-003, 006-006
EMB SB 24-5024 for A/C 001-002
(Ref. Fig. AC Essential Distribution (Emergency Configuration) - Static Inverter
Configuration SHEET 1)
** ON A/C 003-050
PRE SB 24-5024 for A/C 003-003, 006-006

Print Date: October 31, 2016


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 18 of 38

Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-52 - AC ESSENTIAL DISTRIBUTION

(Ref. Fig. AC Essential Distribution (Emergency Configuration) - Static Inverter


Configuration SHEET 1)
** ON A/C ALL
(Ref. Fig. Relay 16XH - Control Logic SHEET 1)
** ON A/C 001-002
POST SB 24-5024 for A/C 003-003, 006-006
EMB SB 24-5024 for A/C 001-002
(Ref. Fig. AC Essential Distribution - Static Inverter Operation in Ground Configuration SHEET 1)
** ON A/C 003-050
PRE SB 24-5024 for A/C 003-003, 006-006
(Ref. Fig. AC Essential Distribution - Static Inverter Operation in Ground Configuration SHEET 1)

Print Date: October 31, 2016


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 19 of 38

Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-52 - AC ESSENTIAL DISTRIBUTION

401PP
28VDC

2
17XH

REF 24-62-00
FIG 1PH
CONTROL LOGIC
1PH CNTOR
DC SHED ESS BUS

16XH-RLY
AC ESS BUS/SHED 401XP

F_MM_245200_0_AYM0_01_00

Figure 24-52-00-14500-00-A / SHEET 1/1 - Relay 16XH - Control Logic


** ON A/C ALL
Print Date: October 31, 2016
AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 20 of 38

Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-52 - AC ESSENTIAL DISTRIBUTION

to the fuel pumps (Ref. AMM D/O 28-21-00-00) .


4. Operation/Control and Indicating
In case of loss of the busbar 901XP, the AC ESS BUS FAULT message is displayed on the Engine/Warning
Display (EWD) and the MASTER CAUT and single chime are triggered.
(Ref. Fig. AC ESS BUS FAULT (Class 1 - Level 2) - EWD/SD)

Print Date: October 31, 2016


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 21 of 38

BUS

LOSS OF AC ESS

SYSTEM
CONFIG.

WHITE "ALTN"

ALTN

FAULT

AC ESS FEED

AMBER "FAULT"

ALTN

FAULT

AC ESS FEED

SYS IND ON
OVHD PANEL

MASTER
CAUT

SINGLE
CHIME

WARNING

NOTE: THE INOP SYST LIST DOES NOT INCLUDE ALL THE INDICATIONS.
FOR MORE INFORMATION, REF. 31-51-24

CLEAR P/BSW
(ON ECAM CTL
PNL)

- AC ESS FEED
ALTN

SELECT:

MANUAL CREW
ACTION

(A)

EWD

Print Date: October 31, 2016


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
NORMAL CONFIG

AC ESS BUS FAULT

CAT 1 ONLY

EFIS DMC 1
ECAM DMC 3
CAPT PITOT
ADR 1
ILS 1
CAT 2
GPWS G/S
ENG 1 IGN A
ENG 2 IGN A
ENG 3 IGN A
ENG 4 IGN A
SDAC 1
FWC 1

INOP SYS

STATUS

ELEC AC PAGE
IS DISPLAYED
(REF SHEET 2)

SD

(B) RECOVERED WHEN LAND RECOVERY P/B IS PRESSED

(A) IF NOT ALREADY USED

ELEC

-AC ESS FEED........ALTN


.IF UNSUCCESSFUL:
-CAPT EFIS DMC........3
-ECAM SWTG DMC........2
-AIR DATA SWTG.CAPT ON3

ELEC AC ESS BUS FAULT

AC ESS BUS FAULT (CLASS 1 - LEVEL 2)

(B)

(B)

Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-52 - AC ESSENTIAL DISTRIBUTION

F_MM_245200_0_AQMA_01_00

Figure 24-52-00-15700-00-A / SHEET 1/2 - AC ESS BUS FAULT (Class 1 - Level 2) - EWD/SD
** ON A/C ALL

Page 22 of 38

Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-52 - AC ESSENTIAL DISTRIBUTION

ELEC
AC

ESS
TR
EMER GEN

STAT INV

AC ESS
TR1
AC1-1

AC1-2

GEN1
62%
116V
400HZ

GEN2
62%
116V
400HZ

IDG1
123 C

IDG2
123

TR2

APU GEN

APU
TR

AC2-3

AC2-4

GEN3
62%
116V
400HZ

GEN4
62%
116V
400HZ

IDG3
123 C

IDG4
123

2WK2
SD
BUSBAR SHOWN IN DOTTED LINE
WHEN DISPLAYED IN AMBER

F_MM_245200_0_AQMA_02_00

Figure 24-52-00-15700-00-A / SHEET 2/2 - AC ESS BUS FAULT (Class 1 - Level 2) - EWD/SD
** ON A/C ALL
Print Date: October 31, 2016
AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 23 of 38

Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-52 - AC ESSENTIAL DISTRIBUTION

In case of loss of the busbar 401XP, the AC ESS BUS SHED message is displayed on the EWD and the
MASTER CAUT and single chime are triggered.
In both cases the ELEC AC page is automatically displayed on the System Display (SD):
(Ref. Fig. AC ESS BUS SHED (Class 1 - Level 2) - EWD/SD)

Print Date: October 31, 2016


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 24 of 38

LOSS OF
AC SHEDDABLE
ESS BUS

SYSTEM
CONFIG

NIL

SYS IND ON
OVHD PANEL

MASTER
CAUT

SINGLE
CHIME

WARNING

NOTE: THE INOP SYST LIST DOES NOT INCLUDE ALL THE INDICATIONS.
FOR MORE INFORMATION, REF. 31-51-24

CLEAR P/BSW
(ON ELEC CTL
PNL)

CREW MANUAL
ACTION

ELEC

EWD

NORMAL CONFIG

AC ESS BUS SHED

AC ESS BUS SHED (CLASS 1 - LEVEL 2)

FUEL PUMP 1
F STBY PUMP4

INOP SYS

STATUS

ELEC AC PAGE
IS DISPLAYED
(REF SHEET 2)

SD

Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-52 - AC ESSENTIAL DISTRIBUTION

F_MM_245200_0_ATMA_01_00

Figure 24-52-00-15850-00-A / SHEET 1/2 - AC ESS BUS SHED (Class 1 - Level 2) - EWD/SD
** ON A/C ALL

Print Date: October 31, 2016


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 25 of 38

Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-52 - AC ESSENTIAL DISTRIBUTION

ELEC
AC

ESS
TR
EMER GEN

STAT INV

AC ESS
TR1
AC1-1

AC1-2

GEN1
62%
116V
400HZ

GEN2
62%
116V
400HZ

IDG1
123 C

IDG2
123

SHED
TR2

APU GEN

APU
TR

AC2-3

AC2-4

GEN3
62%
116V
400HZ

GEN4
62%
116V
400HZ

IDG3
123 C

IDG4
123

2WK2
SD

F_MM_245200_0_ATMA_02_00

Figure 24-52-00-15850-00-A / SHEET 2/2 - AC ESS BUS SHED (Class 1 - Level 2) - EWD/SD
** ON A/C ALL
Print Date: October 31, 2016
AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 26 of 38

Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-52 - AC ESSENTIAL DISTRIBUTION

NOTE: The various indications concerning the AC essential busses on the ELEC AC page are described in Ref.
24-27-00.
** ON A/C 003-050
PRE SB 24-5024 for A/C 003-003, 006-006
Figure 24-52-00-11150-00-D / SHEET 1/1 - AC Essential Distribution (General) - Block Diagram
** ON A/C 001-002
POST SB 24-5024 for A/C 003-003, 006-006
EMB SB 24-5024 for A/C 001-002
Figure 24-52-00-11150-00-K / SHEET 1/1 - AC Essential Distribution (General) - Block Diagram
** ON A/C ALL
Figure 24-52-00-12250-00-A / SHEET 1/1 - AC Essential Distribution - Component Location
** ON A/C 003-050
PRE SB 24-5024 for A/C 003-003, 006-006
Figure 24-52-00-13550-00-D / SHEET 1/1 - AC Essential Distribution (Normal Configuration) - Block Diagram
** ON A/C 001-002
POST SB 24-5024 for A/C 003-003, 006-006
EMB SB 24-5024 for A/C 001-002
Figure 24-52-00-13550-00-K / SHEET 1/1 - AC Essential Distribution (Normal Configuration) - Block Diagram
** ON A/C 003-050
PRE SB 24-5024 for A/C 003-003, 006-006
Figure 24-52-00-13800-00-D / SHEET 1/1 - AC Essential Distribution (Emergency Configuration) - CSM/G Supplied
by the Engine Pump
** ON A/C 001-002
POST SB 24-5024 for A/C 003-003, 006-006
EMB SB 24-5024 for A/C 001-002
Figure 24-52-00-13800-00-K / SHEET 1/1 - AC Essential Distribution (Emergency Configuration) - CSM/G Supplied
by the Engine Pump
** ON A/C 003-050
PRE SB 24-5024 for A/C 003-003, 006-006
Figure 24-52-00-13850-00-D / SHEET 1/1 - AC Essential Distribution (Emergency Configuration) - CSM/G Supplied
by the RAT Pump
** ON A/C 001-002
POST SB 24-5024 for A/C 003-003, 006-006
EMB SB 24-5024 for A/C 001-002
Figure 24-52-00-13850-00-K / SHEET 1/1 - AC Essential Distribution (Emergency Configuration) - CSM/G Supplied
by the RAT Pump
** ON A/C 003-050

Print Date: October 31, 2016


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 27 of 38

Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-52 - AC ESSENTIAL DISTRIBUTION

PRE SB 24-5024 for A/C 003-003, 006-006


Figure 24-52-00-14050-00-D / SHEET 1/1 - AC Essential Distribution (Emergency Configuration) - Static Inverter
Configuration
** ON A/C 001-002
POST SB 24-5024 for A/C 003-003, 006-006
EMB SB 24-5024 for A/C 001-002
Figure 24-52-00-14050-00-K / SHEET 1/1 - AC Essential Distribution (Emergency Configuration) - Static Inverter
Configuration
** ON A/C ALL
Figure 24-52-00-14500-00-A / SHEET 1/1 - Relay 16XH - Control Logic
** ON A/C 003-050
PRE SB 24-5024 for A/C 003-003, 006-006
Figure 24-52-00-14550-00-D / SHEET 1/1 - AC Essential Distribution - Static Inverter Operation in Ground
Configuration
** ON A/C 001-002
POST SB 24-5024 for A/C 003-003, 006-006
EMB SB 24-5024 for A/C 001-002
Figure 24-52-00-14550-00-K / SHEET 1/1 - AC Essential Distribution - Static Inverter Operation in Ground
Configuration
** ON A/C ALL
Figure 24-52-00-15700-00-A / SHEET 1/2 - AC ESS BUS FAULT (Class 1 - Level 2) - EWD/SD
Figure 24-52-00-15700-00-A / SHEET 2/2 - AC ESS BUS FAULT (Class 1 - Level 2) - EWD/SD
Figure 24-52-00-15850-00-A / SHEET 1/2 - AC ESS BUS SHED (Class 1 - Level 2) - EWD/SD
Figure 24-52-00-15850-00-A / SHEET 2/2 - AC ESS BUS SHED (Class 1 - Level 2) - EWD/SD

24-52-00 PB 501 CONF 00 - AC ESSENTIAL DISTRIBUTION - ADJUSTMENT/TEST


TASK 24-52-00-710-801-A
Operational Test of the 905XP Busbar Shedding in Emergency Configuration
1.

Reason for the Job


Refer to the MPD TASK: 245000-03
OPERATIONAL CHECK OF 905XP BUSBAR SHEDDING IN EMERGENCY CONFIGURATION.
Make sure that busbar 905XP is shed in emergency configuration.

Job Set-up Information


A.

Referenced Information
REFERENCE
(Ref. 24-41-00-861-801-A).
(Ref. 24-41-00-861-801-A-01).
(Ref. 24-41-00-861-801-A-03).

DESIGNATION
Energize the Aircraft Electrical Circuits from the External Power A
Energize the Aircraft Electrical Circuits from the APU (APU Started
with APU BAT)
Energize the Aircraft Electrical Circuits from the External Power A and
B

Print Date: October 31, 2016


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 28 of 38

Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-52 - AC ESSENTIAL DISTRIBUTION

REFERENCE
(Ref. 24-41-00-861-801-A-04).
(Ref. 24-41-00-861-801-A-05).
(Ref. 24-41-00-862-801-A).
(Ref. 24-41-00-862-801-A-01).
(Ref. 24-41-00-862-801-A-03).
(Ref. 24-41-00-862-801-A-04).
(Ref. 29-00-00-863-801-A-01).
(Ref. 29-00-00-864-801-A-01).
(Ref. 31-60-00-860-801-A).
(Ref. 31-60-00-860-802-A).
3.

DESIGNATION
Energize the Aircraft Electrical Circuits from the APU (APU started with
External power A)
Energize the Aircraft Electrical Circuits from the External Power B
De-energize the Aircraft Electrical Circuits from the External Power A
De-energize the Aircraft Electrical Circuits from the APU
De-energize the Aircraft Electrical Circuits from the External Power A
and B
De-energize the Aircraft Electrical Circuits from the External Power B
Pressurize the Green Hydraulic System with the Electric Pump
Depressurize the Green Hydraulic System (Pressurized with the Electric Pump)
EIS Start Procedure
EIS Stop Procedure

Job Set-up
Subtask 24-52-00-860-050-A
A.

Aircraft Maintenance Configuration


WARNING: MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS ARE CLEAR.
MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR
DAMAGE.
CAUTION:

DO NOT OPERATE THE FLAPS AND SLATS WHEN ONE OR MORE "LEAK MEASUREMENT VALVES" PUSHBUTTON SWITCHES ARE IN THE RELEASED POSITION ("OFF"
LEGEND ON).
OPERATION OF THE FLAPS AND SLATS IN THIS CONFIGURATION CAN CAUSE
JAMMING OF THE MECHANICAL TRANSMISSION.

(1) Energize the aircraft electrical circuits


(Ref. AMM TASK 24-41-00-861-801) .
(2) Do the EIS start procedure (ECAM system only) (Ref. AMM TASK 31-60-00-860-801) .
(3) Pressurize the Green hydraulic system
(Ref. AMM TASK 29-00-00-863-801) .
(4) On the panel 114VU, make sure that the flap and slat control lever is in RET position.
(5) On the HYD section of the maintenance panel 285VU, release the LEAK MEASUREMENT VALVE/G
pushbutton switch (the OFF legend comes on).
(6) On the center pedestal, on the MCDU 3, turn the BRT knob to the center position (indications are
displayed on the MCDU 3).
Subtask 24-52-00-865-050-A
B.

Make sure that this(these) circuit breaker(s) is(are) closed:


PANEL
721VU
722VU
742VU
742VU
742VU

DESIGNATION
1XP1 VOLT REF/TEST
2XP4 VOLT REF/TEST
AC EMER DET RLY
CSM/G AUTO START
CSM/G OFF CTL

FIN
18XE
21XE
25XE
17XE
24XE

LOCATION
D04
D49
E75
J78
N62

Print Date: October 31, 2016


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 29 of 38

Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-52 - AC ESSENTIAL DISTRIBUTION

PANEL
742VU
4.

DESIGNATION
CSM/G MAN START

FIN
22XE

LOCATION
N61

Procedure
Subtask 24-52-00-710-050-A
A.

Operational Test of Busbar 905XP Shedding in Emergency Configuration


ACTION
RESULT
1.On the center pedestal, on the ECAM control pan- On the SD, on the HYD page:
el:
Make sure that the normal configuration comes in Push the HYD key.
to view.
Make sure that the actual system pressure indication below the GREEN indication is of 3000 -200
psi or +200 psi (206.84 -13.79 bar or +13.79 bar).
NOTE: A minimum hydraulic pressure is necessary
for the CSM/G to start and operate correctly.
2.On the panel 211VU, EMER ELEC section:
On the SD, on the ELEC AC page:
lift the safety cover
the EMER GEN indication is shown in white, the
push and hold the EMER GEN TEST pushbutton
related parameters are shown in green.
switch.
On the MCDU 3:
the display is blank.
3.On the panel 211VU:
On the SD:
release the EMER GEN TEST pushbutton switch. the normal configuration comes into view (the
emergency generator stops).
On the MCDU 3:
indications are displayed.

5.

Close-up
Subtask 24-52-00-860-051-A
A.

Put the Aircraft back to its Initial Configuration


(1) On the MCDU 3:
set the BRT knob to OFF position.
(2) Depressurize the Green hydraulic system
(Ref. AMM TASK 29-00-00-864-801) .
(3) On the HYD section of the maintenance panel 285VU, push the LEAK MEASUREMENT VALVE/G
pushbutton switch (the OFF legend goes off).
(4) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-802) .
(5) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-801) .

TASK 24-52-00-710-802-A
Operational Test of LAND RECOVERY Configuration
1.

Reason for the Job


Refer to the MPD TASK: 245000-02
OPERATIONAL CHECK OF LAND RECOVERY CONFIGURATION.

Print Date: October 31, 2016


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 30 of 38

Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-52 - AC ESSENTIAL DISTRIBUTION

Make sure that LAND RECOVERY busbars are shed in emergency configuration and recovered when the
LAND RECOVERY pushbutton switch is pushed.
2

Job Set-up Information


A.

Fixtures, Tools, Test and Support Equipment


REFERENCE
No specific

B.

QTY DESIGNATION
AR ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE

Work Zones and Access Panels


ZONE/ACCESS
811

ZONE DESCRIPTION

C. Referenced Information
REFERENCE
(Ref. 24-41-00-861-801-A).
(Ref. 24-41-00-861-801-A-01).
(Ref. 24-41-00-861-801-A-03).
(Ref. 24-41-00-861-801-A-04).
(Ref. 24-41-00-861-801-A-05).
(Ref. 24-41-00-862-801-A).
(Ref. 24-41-00-862-801-A-01).
(Ref. 24-41-00-862-801-A-03).
(Ref. 24-41-00-862-801-A-04).
(Ref. 29-00-00-863-801-A-01).
(Ref. 29-00-00-864-801-A-01).
(Ref. 31-60-00-860-801-A).
(Ref. 31-60-00-860-802-A).
3.

DESIGNATION
Energize the Aircraft Electrical Circuits from the External Power A
Energize the Aircraft Electrical Circuits from the APU (APU Started
with APU BAT)
Energize the Aircraft Electrical Circuits from the External Power A and
B
Energize the Aircraft Electrical Circuits from the APU (APU started with
External power A)
Energize the Aircraft Electrical Circuits from the External Power B
De-energize the Aircraft Electrical Circuits from the External Power A
De-energize the Aircraft Electrical Circuits from the APU
De-energize the Aircraft Electrical Circuits from the External Power A
and B
De-energize the Aircraft Electrical Circuits from the External Power B
Pressurize the Green Hydraulic System with the Electric Pump
Depressurize the Green Hydraulic System (Pressurized with the Electric Pump)
EIS Start Procedure
EIS Stop Procedure

Job Set-up
Subtask 24-52-00-860-052-A
A.

Aircraft Maintenance Configuration


WARNING: MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS ARE CLEAR.
MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR
DAMAGE.
CAUTION:

DO NOT OPERATE THE FLAPS AND SLATS WHEN ONE OR MORE "LEAK MEASUREMENT VALVES" PUSHBUTTON SWITCHES ARE IN THE RELEASED POSITION ("OFF"
LEGEND ON).
OPERATION OF THE FLAPS AND SLATS IN THIS CONFIGURATION CAN CAUSE
JAMMING OF THE MECHANICAL TRANSMISSION.

(1) Energize the aircraft electrical circuits


Print Date: October 31, 2016
AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 31 of 38

Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-52 - AC ESSENTIAL DISTRIBUTION

(Ref. AMM TASK 24-41-00-861-801) .


(2) Do the EIS start procedure (ECAM system only) (Ref. AMM TASK 31-60-00-860-801) .
(3) Pressurize the Green hydraulic system
(Ref. AMM TASK 29-00-00-863-801) .
(4) On the panel 114VU, make sure that the flap and slat control lever is in the 0 position.
(5) On the HYD section of the maintenance panel 285VU, release the LEAK MEASUREMENT VALVE/G
pushbutton switch (the OFF legend comes on)
(6) On the ECAM control panel, push the CLR key until the DOOR page comes into view on the SD.
Subtask 24-52-00-010-050-A
B.

Get Access
(1) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at the access door 811.
(2) Open the access door 811.
(3) Open the protective door of the AC/DC emergency power center 740VU.

Subtask 24-52-00-865-051-A
C.

Make sure that this(these) circuit breaker(s) is(are) closed:


PANEL
721VU
722VU
742VU
742VU
742VU
742VU
742VU
742VU
742VU
742VU
742VU
742VU
742VU

4.

DESIGNATION
1XP1 VOLT REF/TEST
2XP4 VOLT REF/TEST
401XP CTL
LAND RCVY BUS SWTG
AC EMER DET RLY
CSM/G AUTO START
LAND RCVY CTL
LGCIU 1
801/805PP SHED CTL
801/805PP CTL
CSM/G OFF CTL
CSM/G MAN START
805PP

FIN
18XE
21XE
17XH
13PH
25XE
17XE
9XC
1GA
4PH
3PH
24XE
22XE
11PH

LOCATION
D04
D49
A77
E80
E75
J78
K64
L63
N64
N63
N62
N61
S77

Procedure
Subtask 24-52-00-710-051-C
A.

Operational Test of LAND RECOVERY Configuration


ACTION
RESULT
1.On the center pedestal, on the ECAM control pan- On the SD, on the HYD page:
el:
Make sure that the normal configuration comes in Push the HYD key.
to view.
Make sure that the actual system pressure indication below the GREEN indication is of 3000 -200
psi or +200 psi (206.84 -13.79 bar or +13.79 bar).
NOTE: A minimum hydraulic pressure is necessary
for the CSM/G to start and operate correctly.
2.On the ECAM control panel:
Push the EL/AC key.

On the SD, on the ELEC AC page:


The normal configuration comes into view.

Print Date: October 31, 2016


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 32 of 38

Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-52 - AC ESSENTIAL DISTRIBUTION

ACTION
RESULT
3.On the panel 211VU, EMER ELEC section:
On the panel 211VU:
Push the LAND RECOVERY pushbutton switch. The ON legend of the LAND RECOVERY pushbutton switch comes on.
4.On the panel 211VU, EMER ELEC section:
On the SD, on the ELEC AC page:
Lift the safety guard.
The green line between the AC1-1 busbar and the
Push and hold the EMER GEN TEST pushbutton AC ESS busbar goes out of view.
switch.
The EMER GEN indication is shown in white, the
related parameters are shown in green.
The green line between the EMER GEN and the
AC ESS busbar comes into view.
The amber SHED indication comes on on the right
of the AC ESS busbar.
On the EWD:
The DC ESS BUS SHED and AC ESS BUS SHED
indications come into view, accompanied by the
single chime and the MASTER CAUT.
5.On the panel 211VU:
On the panel 211VU:
Release the LAND RECOVERY pushbutton
The ON legend of the LAND RECOVERY pushbutswitch.
ton switch goes off.
6.On the ECAM control panel:
On the SD, on the STATUS page:
Push the STS key.
The LGCIU 1 indication comes into view on the INOP SYS part.
NOTE: Ignore all the other warnings that can come
into view and are not given in this test procedure.
7.On the panel 211VU:
On the panel 211VU:
Push the LAND RECOVERY pushbutton switch. The ON legend of the LAND RECOVERY pushbutton switch comes on.
On the SD, on the STATUS page:
The LGCIU 1 indication goes out of view.
8.On the panel 211VU:
On the SD, on the ELEC AC page:
Release the EMER GEN TEST pushbutton
The normal configuration comes into view (the
switch.
CMS/G stops).
On the EWD:
The DC ESS BUS SHED and AC ESS BUS SHED
indications go out of view.
9.On the panel 211VU:
On the panel 211VU:
Release the LAND RECOVERY pushbutton
The ON legend of the LAND RECOVERY pushbutswitch.
ton switch goes off.
5.

Close-up
Subtask 24-52-00-860-053-A
A.

Put the Aircraft back to its Initial Configuration


(1) Depressurize the Green hydraulic system
(Ref. AMM TASK 29-00-00-864-801) .
(2) On the HYD section of the maintenance panel 285VU, push the LEAK MEASUREMENT VALVE/G
pushbutton switch (the OFF legend goes off)
(3) Do the EIS stop procedure

Print Date: October 31, 2016


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 33 of 38

Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-52 - AC ESSENTIAL DISTRIBUTION

(Ref. AMM TASK 31-60-00-860-802) .


(4) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-801) .
Subtask 24-52-00-410-050-A
B.

Close Access
(1) Close the protective door of the AC/DC emergency power center 740VU.
(2) Close the access door 811.
(3) Remove the access platform(s).

24-52-51 - AUTO TRANSFORMER - ESSENTIAL, 115/26VAC


24-52-51 PB 401 CONF 00 - AUTO TRANSFORMER ESSENTIAL, 115/26VAC - REMOVAL/INSTALLATION
TASK 24-52-51-000-801-A
Removal of the Essential 115/26VAC Autotransformer
WARNING:

MAKE SURE THAT NO AC OR DC POWER SOURCE IS CONNECTED TO THE AIRCRAFT


ELECTRICAL CIRCUITS.
THERE IS A RISK OF ELECTROCUTION IF THE AC OR DC POWER STAYS CONNECTED.

FIN : 3XH
1.

Reason for the Job


Self explanatory

Job Set-up Information


A.

Fixtures, Tools, Test and Support Equipment


REFERENCE
No specific
No specific
No specific
No specific

B.

QTY
AR
AR
AR
AR

DESIGNATION
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
CAP - BLANKING
SAFETY CLIP - CIRCUIT BREAKER
WARNING NOTICE(S)

Work Zones and Access Panels


ZONE/ACCESS
121
121EL, 811

ZONE DESCRIPTION
AVIONICS COMPARTMENT

C. Referenced Information
REFERENCE
DESIGNATION
Essential Autotransformer SHEET 1

Print Date: October 31, 2016


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 34 of 38

Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-52 - AC ESSENTIAL DISTRIBUTION

A
740VU

FR10
3XH

FR7
811

2
3

2
3
F_MM_245251_4_AAM0_01_00

Figure 24-52-51-991-00100-00-A / SHEET 1/1 - Essential Autotransformer


** ON A/C ALL
Print Date: October 31, 2016
AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 35 of 38

Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-52 - AC ESSENTIAL DISTRIBUTION

3.

Job Set-up
Subtask 24-52-51-941-050-A
A.

Safety Precautions
(1) In the cockpit, on the ELEC control panel 235VU, make sure these pushbutton switches are released:
BAT 1, BAT 2, APU BAT,
GEN 1 (2, 3, 4), APU GEN,
EXT A(B).
(2) In the cockpit, put a WARNING NOTICE(S) to tell persons not to operate the pushbutton switches on
these panels of the overhead panel:
211VU (EMER ELEC PWR),
235VU (ELEC).
(3) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at the access door 121EL.
(4) Make sure that the external power connector(s) is(are) not connected to the aircraft receptacle(s) EXT
PWR A(B).
(5) Put a WARNING NOTICE(S) on the access door 121EL to tell persons not to connect the external
power connector(s).

Subtask 24-52-51-010-050-A
B.

Get Access to the Avionics Compartment


(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at the access door 811.
(2) Open the access door 811.

Subtask 24-52-51-865-050-A
C.

Open, safety and tag this(these) circuit breaker(s):


PANEL
742VU

DESIGNATION
26VAC 931XPA

FIN
9XH

LOCATION
R64

Subtask 24-52-51-010-051-A
D.

Get Access
(1) Open the protective door of the AC/DC emergency power center 740VU.
(2) Open the panel 742VU.

4.

Procedure
(Ref. Fig. Essential Autotransformer SHEET 1)
Subtask 24-52-51-020-050-A
A.

Removal of the Autotransformer


(1) Disconnect the electrical connector (1).
(2) Put blanking caps on the disconnected electrical connectors.
(3) Remove the four screws (3) and the four washers (2).
(4) Remove the autotransformer (4).

TASK 24-52-51-400-801-A
Installation of the Essential 115/26VAC Autotransformer
WARNING:

MAKE SURE THAT NO AC OR DC POWER SOURCE IS CONNECTED TO THE AIRCRAFT


ELECTRICAL CIRCUITS.

Print Date: October 31, 2016


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 36 of 38

Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-52 - AC ESSENTIAL DISTRIBUTION

THERE IS A RISK OF ELECTROCUTION IF THE AC OR DC POWER STAYS CONNECTED.

FIN : 3XH
1.

Reason for the Job


Self explanatory

Job Set-up Information


A.

Fixtures, Tools, Test and Support Equipment


REFERENCE
No specific
No specific

B.

QTY DESIGNATION
AR ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
AR WARNING NOTICE(S)

Work Zones and Access Panels


ZONE/ACCESS
121
121EL, 811

ZONE DESCRIPTION
AVIONICS COMPARTMENT

C. Referenced Information
REFERENCE
DESIGNATION
(Ref. 34-13-00-740-803-A).
SYSTEM TEST of the Air Data Reference (ADR)
Essential Autotransformer SHEET 1
3.

Job Set-up
Subtask 24-52-51-860-050-A
A.

Aircraft Maintenance Configuration


(1) In the cockpit, on the ELEC control panel 235VU, make sure these pushbutton switches are released:
BAT 1, BAT 2, APU BAT,
GEN 1 (2, 3, 4), APU GEN,
EXT A(B).
(2) Make sure that there is a WARNING NOTICE(S) in the cockpit to tell persons not to operate the
pushbutton switches on these panels of the overhead panel:
211VU (EMER ELEC PWR),
235VU (ELEC).
(3) Make sure that the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE is in position at the access door
121EL.
(4) Make sure that the external power connector(s) is(are) not connected to the aircraft receptacle(s) EXT
PWR A(B).
(5) Make sure that the WARNING NOTICE(S) is on the access door 121EL to tell persons not to connect
the external power connector(s).
(6) Make sure that the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE is in position at the access door
811.
(7) Make sure that the access door 811 is open.
(8) Make sure that the protective door of the AC/DC emergency power center 740VU is open.

Print Date: October 31, 2016


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 37 of 38

Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-52 - AC ESSENTIAL DISTRIBUTION

(9) Make sure that emergency circuit breaker panel 742VU is open.
Subtask 24-52-51-865-051-A
B.

Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANEL
742VU

4.

DESIGNATION
26VAC 931XPA

FIN
9XH

LOCATION
R64

Procedure
(Ref. Fig. Essential Autotransformer SHEET 1)
Subtask 24-52-51-420-050-A
A.

Installation of the Autotransformer


(1) Clean the component interface and/or the adjacent area.
(2) Do a visual inspection of the component interface and/or the adjacent area.
(3) Put the autotransformer (4) in position.
(4) Install the four washers (2) and the four screws (3) and then tighten the screws.
(5) Remove the blanking caps from the electrical connectors.
(6) Make sure that the electrical connectors are clean and in the correct condition.
(7) Connect the electrical connector (1).

Subtask 24-52-51-865-052-A
B.

Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANEL
742VU

DESIGNATION
26VAC 931XPA

FIN
9XH

LOCATION
R64

Subtask 24-52-51-710-050-A
C.

5.

Do this test:
do the SYSTEM TEST of the ADR1 (Ref. AMM TASK 34-13-00-740-803) .
Check that "AOA SENSOR 1 (3FP1) SPLY" indication is not displayed.

Close-up
Subtask 24-52-51-410-050-A
A.

Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the emergency circuit breaker panel 742VU.
(3) Close the protective door of the AC/DC emergency power center 740VU.
(4) Close the access doors 811, 121EL.
(5) Remove the warning notice(s).

(6) Remove the access platform(s).


Figure 24-52-51-991-00100-00-A / SHEET 1/1 - Essential Autotransformer

End of document