You are on page 1of 9
Aare at MRPL Pi S.No DESCRIPTION UOM Agreed Rate 4 1 [INSTALLATION OF INSTRUMENTS . 1.1 |Pressure instruments | 1.1.1 |(a) Pressure Gauges with/without accessories ‘on pipe lines Nos. 300 on vessels Nos 300 (b) Diaphragm Seal Type on pipe lines Nos 350 on vessels Nos 350 1.1.2](a) Electronic Pressure Transmitters on pipe lines Nos 400 ‘on vessels ‘Nos 400 \(b) Diaphragm Seal Type ‘on pipelines. Nos 600 ‘on vessels Nos 600 1.1.3 |Differential Pressure Instruments (a) Differential Pressure gauges with/without accessories ‘on pipe lines Nos 400 ‘on vessels Nos 400 (b) Diaphragm Seal Type on pipe lines Nos 400 ‘on vessels Nos 400 1.1.4|(a) Electronic Pressure Differential Transmitters S.No DESCRIPTION uom | Agreed Rate 1.6.3) 1.6.4 |Thermocouple (K-type) with thermowell [Skin Thermocouples Nos Nos 300 1300 1.6.5 1.6.6) Multi-point Thermocouple [Electronic Temperature transmitter le Nos Nos 2000 350 JUNCTION BOX AND LOCAL PANELS 34 Certified Eex'd' (Ex-Proof) Junction Boxes, Push Button |Stations Local Panels & Power Distribution Boxes for Zone 2, Gr. IC T3 Area Foundation Fieldbus JUNCTION BOX - Non Incendive- SS Material lway FF Mega Block: = 30 terminal Block with internal short circuit protection. |- 420 (F) Branch Cable Entries at bottom - 8 Nos {iP-65, SS, W/Shorting links, Earth Stud Suitable for 1 No of B- Nos —_|—— 550 EO ARRAS Ea RO sea ble tor ZNO or way FF Mega Blocks: - 54 terminal Block with internal short circuit protection. - M20 (F) Branch Cable Entries at bottom - 16 Nos RE AER Sang Te ERS Scaois tor No ore way & 4-way FF Mega Blocks: - 54 terminal Block with Internal short circuit protection. - M20 (F) Branch Cable Entries at bottom - 12 Nos -65, SS, W/Shorting links, Earth Stu ible for 3 Nos of 4 way FF Mega Blocks: = 42 terminal Block with Internal short circuit protection. - M20 (F) Branch Cable Entries at bottom - 12 Nos Foundation Fleldbus JUNCTION BOX - Weather Proof to P65: Area Classification Zone-1, Gas Group — IIC, T3- SS IMaterial Nos Nos Nos. 650 650 600 S.No DESCRIPTION orung Tm UITaBTe Tor 7 way FF Brick (Wiring Block) Mega Block, With Short Circuit Protection for Each Spur and FF Terminator. FF Brick shall be powered from Certified FF Power Supply located in Safe JArea(Control Room) : - 54 terminals for terminating Trunk & Spur Cables. Internal lWiring from Terminal to FF Brick shall be provided by supplier. Block with internal short circuit protection. Block with internal short circuit protection, M20 (F) Branch Cable Entries at bottom - 16 Nos UOM | Agreed Rate Nos 650 PRES SS ARRAS Finca SSE Soa Tort No ore way & 4-way FF Brick (Wiring Block) Mega Block, With Short Circuit Protection for Each Spur and FF Terminator. FF Brick shall be powered from Certified FF Power Supply lecatad in Safe larea(Control Room) : - 54 terminal for terminating Trunk & Spur Cables, Internal \Wiring from Terminal to FF Brick shall be provided by supplier. Block with internal short circuit protection. Block with internal short circuit protection. Block with internal short circuit protection. }- M20 (F) Branch Cable Entries at bottom - ae Nos = M25 (61 3 0: Nos 650 ho air Cable Entries at hattas WERTHERPROOF JUNCTION BOXLMG MATERIAL 1P-65, W/Shorting links, Earth Stud Suitable for: }- 12 Pair with 48 terminal Block. }- M35(F) 2Nos. Bottom Entries for Multipair Cables. Nes 500 Fee Bie Ee Alose ean eee) Marten orsde WShorIng links, Earth Stud Suitable fc - 8 Triad with 48 terminal Block. - 1.1/2" NPT(F) (2Nos.) Bottom Entries for Multipair Cables, }- 1/2" NPT(F) Branch Cable Entries 4(Right) and 4{Left), = Nes 500 EX-PROOF JUNCTION BOX - Flameproof - LM6 MATERIAL {1P-65, W/Shorting links, Earth Stud Suitable for: |- 12 Pair with 48 terminal Block. |- M35(F) 2Nos. Bottom Entries for Multipair Cables. 3-WAY JUNCTION BOX - LMG MATERTAL f= Nos 550 1-65, W/Shorting links, Earth Stud Suitable for: - 1 Pair with 6 terminal Block. - M20(F) 4Nos. TEMPERATURE MULTIPLEXERS- LM6 JBS Nos 120 Nos 800 CABLES 42.4) ISIGNAL / CONTROL CABLE LAYING Incl. Consumables Clamy Ps, Tags, Ties etc 12P X 1.5 mm2,1S, 10S, ARMOURED-FR S.No DESCRIPTION uom | agreed Rate : B |12P X 1.5 mm2,NON-IS, 10S, ARMOURED-FR Meters 16 C |12P X 4.5 mm2,NON-IS, OS, ARMOURED-FR-SOV Meters, 16 Der x 1.5 mm2,IS, 105, ARMOURED-FR . Meters 12.5 & [1p x 1.5 mm2,IS, OS, ARMOURED-FR Meters 85 F |1P X 1.5 mm2NON-IS, OS, ARMOURED-FR Meters as G |1P X 1.5 mm2NON-IS, OS, ARMOURED-FR-SOV Meters 8.5 H_ |12P X0.5 mm2,NON-IS, 0S, ARMOURED-FR Meters 1s, 1 |FF Spur cable of size 1P-18AWG Meters 8s J |FF Trunk cable of size 2P-16AWG Meters 8.5 afremmonoeres EXTENSION CABLE Incl. Consumables Clamps, Tags, Ties etc Tees etc. (No separate measurement for accessories) A |1P X 16 AWG,IS, OS, ARMOURED-FR Meters: 8.5 4.1.3|GAS DETECTOR CABLES Incl. Consumables Clamps, Tags, Tles etc A er x1.5 mma, 1S, 10, ARMOURED-FRLS ] Meters 7 B }1TX 1.5 mm2,.1S, OS, ARMOURED-FRLS- Meters lk 6.5 4.1.4] SERIAL CABLE (FIBRE OPTIC) Incl. Consumables Clamps, Tags, Ties ete A |SC,ARMOURED (Incl HOPE CONDUIT) Meters: 40 | 4.1.5|FIELD BUS CABLE Incl, Consumables Clamps, Sleeves, Tags, Ties etc Fiype A Cable (1 P x 1.3i)Type A, Twisted Pair, Armoured overall R Meters 8.5 shield to IEC61158-2 @ | Ivpe A Cable (2P x 1.31)Type A, Twisted Pair, Armoured ae ie Individual & overall shield to JEC 61158-2 = © [Type A Cable (3 x 1.31)Type A, Twisted Pair, Armoured Ras a Individual & overall shield to IEC 61158-2 Type A Cable (4 P x 1.31)Type A, Twisted Pair, Armoured > individual & overall shield to TEC 6158-2 het, 18 4,1.6| EARTHING CABLE Incl, Consumables Clamps, Tags, Ties etc A |1C -6 mm2,PVC insulated multi stranded Copper Cable- Meters 10 5 ICABLE DUCT AND TRAYS. Rate includes erection of Bends, ) hes 3) [jn opera” yao” S.No DESCRIPTION uoM Agreed Rate 5.1 |GI Cable Trays (2 mm Thick) | 1 [60 mm(w) x 20 mm(H) Meters 40 2 [ro mm(W) x 30 mm(H) . Meters 45 3. [150 mm(W) x 30 mm(H) Meters 60 4 |300 mm(W) x 30 mm(H) Meters 90 5.2 |ERP Trays eT 1 160 mm(W) x 20 mm(H) 40 aye memn(W) x 30 mm(H) 50 3 [150 mmcw) x 30 mm(H) 60 4 [300 mm(w) x 30 mm(H) 80 5,3 |GI Cable Duct (3.2 mm Thick) 1200 mm(W) x 400 mm(H) 2 |400 mmcw) x 200 mm(H) Meters Meters, 450 380 6.1 |Analyser Instruments (Under System Supplier Supervision) [carmen work for all below analyser packages: [Connection of Reference Gas, Cylinders and Utilities to the lvendor provided Tie-in points. Provision of Sunshade / Canopy for Calibration Gas Cylinders Laying of Heated sample and Vent tubing , Laying and Termination of Signal , Temperature , Power cables etc. from probes to cabinet including proper supporting, termination, |ferruting etc as per Analyzer Supplier's Drawing / Document, all packages) Laying of Fibre Optic cable from Analyser House to DCS (Total for| | Installation of Probes [Tastallation of Sample Handling System, HVAC at site and [Earthing from Analyser shelters to Earthing system 6.1.1 Analyser Shelter (with HVAC systems) Nos. 18000 6.1.2] Environment Analysers (SOx, NOx, CO) Nos. 6500 A aanet woth see S.No DESCRIPTION vom | Agreed Rate 6.1.3] Oxygen Analyser Nos. “6500 6.1.6]HC Analyser Nos. 6500 1.12102 Analyser Nos. 6500 =| 1.13.60 Analyser Nos. 6500 1.140 + C02 Analyser Nos. 6500 6.2 |FIRE & GAS DETECTORS |eatoration of detectors, testing of complete system. ‘Installation of HC Gas detectors (LEL Type) , transmitters & Nos. 175 receivers. 4 Installation of H2 Gas detectors, transmitters & receivers. | Nos. 175 6.2.3]installation of H2S Gas detectors, transmitters & recelvers. Nos. 175 6.2.4 [installation of Beacons Nos. 175 6.2.5 [Installation of Electronic Hooters Nos. 175 Installation of Multi Cable Transit complete with frame (Stainless Steel), end packing, compression plates, stay plates, Insert Blocks, Solid Blocks, Sealing strips, etc, make Brattberg or 7 Jequivaient as per MCT block layout, The frame may consists Frames 6000 various sizes of blocks from size 20 to size 60. The type of cables to be laid through MCTs are already defined in this work volume labove (instrument cables, power cables, fibre optic cables, ete.) 13 [HARDWARE FOR INSTALLATION Supply of structural steel including fabrication of the same for |__|the purpose of supports, galvanizing etc, for installation work [The structural steel supplied for fabrication of various instrument items supports, base frames etc. Fabrication and Installation of stanchion as per the standard Jérawing including supply of raw material and other accessories required for fixing of instrument on It Fabrication and erection of Structural Steel including all 13.14) -onsumables, touch up painting. L&T will issue sand biasted steel T"S ea B_ |2" Stanchain pipe Fabrication including consumables Nos 300 | cz" stanchain pipe Erection including consumables Nos 200 fa ~ s° | ! S.No. DESCRIPTION uoM | Agreed Rate 14 |!rstallation of Pre fabricated FRP canopies (4 mm Thick) required for covering the instruments, pos 350, Installation of Pre fabricated FRP canopies (4 mm Thick) a — required for covering the junction boxes = 2 45 |IMPULSE HOOK UP 7 Installation of Prefabricated hook ups including Hydro testing & 15-1 |weiging of two joints CS Line Nos 800 ss tine Nos 1000 |AS Line Nos 1000 Fabre n_and installation of hook ups including consumables 15:2 fond impulse line painting 115.2. 1]Pressure Gauges Piping Hookup-CS Nos 1450 Piping Hookup-SS Nos 1450 Is Piping Hookup-AS. Nos 1450 }15.2.2|Pressure Gauges (Diaphragm Seal Type) | [Being Hookup-CS Nos 1450 Piping Hockup-SS- Nos 1450 j— Piping Hookup-AS Nos 1450 | 15.2.3 DP Gauges Piping Hookup-CS Nos 1450 Piping Hookup-SS Nos 1450 Piping Hookup-AS Nos 1450 DP Gauges (Diaphragm Seal Type) Piping Hookup-CS- Nos. 1450 Piping Hookup-SS Nos 1450 Piping Hookup-AS Nos 1450 Us| — wry S.No DESCRIPTION uOM | Agreed Rate te 15.3 [Electronic Pressure Transmitters Piping Hookup-cs Nos 3500 Piping Hookup-SS + Nos +3500 Piping Hookup-AS Nos 3500 Tea 5 Electronic Pressure Transmitters (Diaphragm Seal Type) [Piping Hookup-CS Nos 3500 Piping Hookup-SS Nos +3500 Piping Hookup-AS Nos 3500 15.4 [Electronic Differential Pressure (Flow, Level, PD Transmitter) Piping Hookup-CS Nos 6000 Piping Hookup-SS Nos 6000 Piping Hookup-AS Nos 6000 15.5 |Level Gauges | Piping Hookup-CS- Nos 1500 Joiping Hookup-ss Nos 1500 Piping Hookup-AS 1500 16 |Steam tracing of Instrument Impulse 16.1 |LP steam tracing bes PTs Nos 650 LG” Nos 650 ur [nes 650 FT Nos 850 [Sampling connection Nos 650 =T S.No DESCRIPTION uom | Agreed Rate =| 7 17.1|SS tube 6 mm OD Meters 55 + 17.2|SS Pipe (1") Meters 250 17.3|SS Pipe (1/2") : Meters 125 ye. [Sanding & Termination including supply of Ferrules, plugs, Sleeves and Lugs but excluding Glands & Shrouds 1 |M20a@mi2 Nos 95 2 |mes Nos 100 3 [M32 Nos 130 4 [maz Nos 140 5 [M50 Nos 160 Note 1. All the tools & tackles are in the scope of Contractor 2: P&M required to shift equipments like Hydra, crane & Truck will be provided by L&T 3. All Consumables are in the scope of contractor |4. Safety PPEs to be provided by L&T 5, Accomodation for Labour to be provided by L&T 6. All statutory charges for the workers like PF, ESI shall be in the scope of contractor Contractor to maintain the records as per the statutory norms and submit the documents monthly to monthly to L&T 7. Conveyance to workers shall be provided by the contractor 8. Scaffholding will be done by L&T 9. Safety Custoday of the free issue materials Is in the scope of contractor 10, Monthly reconciliation report to be submitted along with the bill 41. Payment will be done monthly gh * (Ly. \

You might also like