QP-022201-03-21
ASSEMBLED EQUIPMENT: API 6A/ ISO 10423 PSL-3, PSL-3G, ALL PRESSURES, ALL TEMPERATURE RATINGS, ALL MATERIAL CLASSES
CUSTOMER
BP (SP-007057)
INSPECTION /
TEST ACTIVITY
CUSTOMER
NOTIFICATION
STANDARD (1)
CAMERON SP /
CUSTOMER
REQUIREMENT
DOC
Y/N(2)
SAMPLE
SIZE (3)
CUSTOMER
INSPECTION
THE DEFINITIONS OF HOLD POINT, MONITOR POINT AND DOCUMENT REVIEW POINT ESTABLISHED IN
THIS SECTION SHALL APPLY AS FOLLOWS:
HOLD POINT:
CAMERON SHALL NOTIFY THE INDICATED PARTIES A MINIMUM OF 48 HOURS PRIOR TO REACHING THE
ACTIVITY UNLESS OTHERWISE AGREED BY THE INDICATED PARTIES AT PPM. CAMERON MAY NOT
PROCEED PAST THE ACTIVITY WITHOUT THE NIBS PRESENCE. IN THE UNLIKELY EVENT THAT A HOLD
POINT MAY BE WAIVED, CAMERON SHALL OBTAIN WRITTEN APPROVAL (E-MAIL OR FAX IS ACCEPTABLE)
FROM THE INDICATED PARTIES PRIOR TO PROCEEDING PAST THE ACTIVITY. THE NIB WILL SIGN /
STAMP DOCUMENTATION WHEN AN ACTIVITY HAS BEEN OBSERVED BY THE NIB.
MONITOR POINT:
BP RESERVES THE RIGHT TO USE AN NIB TO MONITOR ACTIVITIES IN PROGRESS. NO FORMAL
NOTIFICATION IS REQUIRED, HOWEVER CAMERON SHALL KEEP THE INDICATED PARTIES AND NIB WELL
INFORMED OF THE WORK SCHEDULE. CAMERON MAY PROCEED WITH THE ACTIVITY WITHOUT THE
NIBS PRESENCE.
DOCUMENT REVIEW:
THE NIB WILL REVIEW DOCUMENTATION ASSOCIATED WITH THE ACTIVITY. NO FORMAL NOTIFICATION
IS REQUIRED, EXCEPT FOR FINAL MRB REVIEW. THE NIB SHALL HAVE THE OPTION TO REVIEW THE
IDENTIFIED RECORD OF ACCEPTANCE ASSOCIATED WITH AN ACTIVITY FROM THE TIME THE ACTIVITY
IS COMPLETED. REVIEW OF DOCUMENTATION SHALL NOT BE LIMITED TO SET-OUT INSPECTION OR
FINAL MRB REVIEW. THE NIB REVIEW OF THE MRB PACKAGE CAN EFFECTIVELY COMMENCE ONCE THE
INITIAL ASSEMBLY SET-OUT INSPECTION HAS BEEN COMPILED. REVIEWS FROM THIS STAGE SHALL BE
ON-GOING UNTIL THE ASSEMBLY DOCUMENTATION IS RELEASED
NOTIFICATION FOR CUSTOMER INSPECTION SHALL INCLUDE, AS A MINIMUM, THE BELOW
INFORMATION:
BP REGION PROJECT
BP REGION EQUIPMENT PURCHASE ORDER / CONTRACT / CALLOFF NUMBER
CAMERON SALES ORDER
PART IDENTIFICATION (CAMERON PART NUMBER AND REVISION, PART DESCRIPTION, CAMERON
PURCHASE ORDER AND/OR WORK ORDER NUMBER)
NOTE: CAMERON PURCHASE ORDER, CAMERON BILL OF MATERIAL (BOM) AND ALL RELATED CAMERON
SPECIFICATIONS HAS TO BE MADE AVAILABLE FOR CUSTOMER INSPECTION REVIEW AS REQUIRED.
(1) REVISION LEVEL IS CURRENT REVISION UNLESS OTHERWISE NOTED OR NOT COVERED BY API/ ISO.
(2) VERIFYING / INSPECTION RECORDS FOR THE INSPECTION/TEST ACTIVITY
(3) EQUIPMENT SAMPLE SIZE REQUIRED FOR THE INSPECTION/TEST ACTIVITY
QP-022201-03-21
PROPERTY OF
DWN BY
DWN DATE
APVD BY
APVD DATE
SHEET
REVISION
LENA CHNG
3 SEP 2015
TANG NAI AN
3 SEP 2015
2 OF 8
02
QP-022201-03-21
ASSEMBLED EQUIPMENT: API 6A/ ISO 10423 PSL-3, PSL-3G, ALL PRESSURES, ALL TEMPERATURE RATINGS, ALL MATERIAL CLASSES
CUSTOMER
BP (SP-007057)
INSPECTION /
TEST ACTIVITY
STANDARD (1)
NON-CONFORMANCE
(NC)
CAMERON SP /
CUSTOMER
REQUIREMENT
DEVIATION /
CONCESSION
REQUEST
CAMERON SP /
CUSTOMER
REQUIREMENT
DOC
Y/N(2)
SAMPLE
SIZE (3)
CUSTOMER
INSPECTION
YES
100%
YES
100%
HOLD FOR
APPROVAL
YES
100%
HOLD FOR
APPROVAL
YES
100%
RECEIVING
INSPECTION FOR
INTER-COMPANY
EQUIPMENT
CUSTOMER
REQUIREMENT
FACILITY
PROCEDURE
(1) REVISION LEVEL IS CURRENT REVISION UNLESS OTHERWISE NOTED OR NOT COVERED BY API/ ISO.
(2) VERIFYING / INSPECTION RECORDS FOR THE INSPECTION/TEST ACTIVITY
(3) EQUIPMENT SAMPLE SIZE REQUIRED FOR THE INSPECTION/TEST ACTIVITY
QP-022201-03-21
PROPERTY OF
DWN BY
DWN DATE
APVD BY
APVD DATE
SHEET
REVISION
LENA CHNG
3 SEP 2015
TANG NAI AN
3 SEP 2015
3 OF 8
02
QP-022201-03-21
ASSEMBLED EQUIPMENT: API 6A/ ISO 10423 PSL-3, PSL-3G, ALL PRESSURES, ALL TEMPERATURE RATINGS, ALL MATERIAL CLASSES
CUSTOMER
BP (SP-007057)
INSPECTION /
TEST ACTIVITY
TRACEABILITY / SETOUT
STANDARD (1)
API 6A/ ISO10423
CAMERON BOM
DOC
Y/N(2)
SAMPLE
SIZE (3)
CUSTOMER
INSPECTION
YES
100%
HOLD / MONITOR*
YES
100%
MONITOR
NO
100%
MONITOR
NO
100%
MONITOR
YES
100%
HOLD
TRACEABILITY/
MARKING OF
INDIVIDUAL
EQUIPMENT
MARKING OF
CHRISTMAS TREES
(AS APPLICABLE)
MARKING OF
ASSEMBLIES OF
VALVES WITH
ACTUATORS
(AS APPLICABLE)
HYDROSTATIC BODY
TEST - INDIVIDUAL
EQUIPMENT
(AS APPLICABLE)
ACCEPTANCE CRITERIA:
CAMERON BOM WITH MINIMUM REQUIREMENT OF SERIALIZATION. ALL MARKING MUST BE LEGIBLE.
NOTE: SERIAL NUMBER SHOULD NOT EXCEED 18 CHARACTERS LONG.
ACCEPTANCE CRITERIA:
MINIMUM REQUIREMENTS: FINAL ACCEPTANCE DATE, NAME/ ID AND LOCATION OF ASSEMBLER
ACCEPTANCE CRITERIA:
SHALL SHOW NO VISIBLE LEAKAGE UNDER TEST PRESSURE.
REPORT TO INCLUDE ACTUAL TEST PRESSURE, DURATION, AND START / STOP TIMES.
(1) REVISION LEVEL IS CURRENT REVISION UNLESS OTHERWISE NOTED OR NOT COVERED BY API/ ISO.
(2) VERIFYING / INSPECTION RECORDS FOR THE INSPECTION/TEST ACTIVITY
(3) EQUIPMENT SAMPLE SIZE REQUIRED FOR THE INSPECTION/TEST ACTIVITY
QP-022201-03-21
PROPERTY OF
DWN BY
DWN DATE
APVD BY
APVD DATE
SHEET
REVISION
LENA CHNG
3 SEP 2015
TANG NAI AN
3 SEP 2015
4 OF 8
02
QP-022201-03-21
ASSEMBLED EQUIPMENT: API 6A/ ISO 10423 PSL-3, PSL-3G, ALL PRESSURES, ALL TEMPERATURE RATINGS, ALL MATERIAL CLASSES
CUSTOMER
BP (SP-007057)
INSPECTION /
TEST ACTIVITY
HYDROSTATIC BODY
TEST - INDIVIDUAL
EQUIPMENT
(AS APPLICABLE)
CONTINUED
STANDARD (1)
CUSTOMER
REQUIREMENT
DOC
Y/N(2)
SAMPLE
SIZE (3)
CUSTOMER
INSPECTION
YES
100%
HOLD
A CHART RECORDER SHALL BE USED ON ALL HYDROSTATIC TESTS. CHARTS SHALL IDENTIFY THE
RECORDING DEVICE UNIQUE IDENTIFIER AND BE SIGNED AND DATED. IF CHARTS RECORDER USED
DURING TESTING IS NOT CALIBRATED, THE TEST CHART SHALL BE MARKED WITH THE STARTING AND
ENDING TEST PRESSURES TAKEN FROM THE CALIBRATED PRESSURE GAGE/TRANSDUCER.
NOTE:
TEST FLUID SHALL BE TREATED WITH RUST PREVENTIVE.
HYDROSTATIC TEST SHALL BE CARRIED OUT PRIOR TO PAINTING OR COATING. IF THE BODIES AND
OTHER PRESSURE CONTAINING PARTS HAVE BEEN MADE OF WROUGHT MATERIAL, TEST MAY BE
COMPLETED AFTER PRIMER LAYERS.
AFTER HYDROSTATIC TESTING, EQUIPMENT SHALL BE VISUALLY INSPECTED FOR MECHANICAL
DAMAGE.
HYDROSTATIC BODY
TEST CHRISTMAS TREES/
EQUIPMENT
ASSEMBLIES
(AS APPLICABLE)
CUSTOMER
REQUIREMENT
A CHART RECORDER SHALL BE USED ON ALL HYDROSTATIC TESTS. CHARTS SHALL IDENTIFY THE
RECORDING DEVICE UNIQUE IDENTIFIER AND BE SIGNED AND DATED. IF CHARTS RECORDER USED
DURING TESTING IS NOT CALIBRATED, THE TEST CHART SHALL BE MARKED WITH THE STARTING AND
ENDING TEST PRESSURES TAKEN FROM THE CALIBRATED PRESSURE GAGE/TRANSDUCER.
NOTE:
TEST FLUID SHALL BE TREATED WITH RUST PREVENTIVE.
HYDROSTATIC TEST SHALL BE CARRIED OUT PRIOR TO PAINTING OR COATING. IF THE BODIES AND
OTHER PRESSURE CONTAINING PARTS HAVE BEEN MADE OF WROUGHT MATERIAL, TEST MAY BE
COMPLETED AFTER PRIMER LAYERS.
AFTER HYDROSTATIC TESTING, EQUIPMENT SHALL BE VISUALLY INSPECTED FOR MECHANICAL
DAMAGE.
(1) REVISION LEVEL IS CURRENT REVISION UNLESS OTHERWISE NOTED OR NOT COVERED BY API/ ISO.
(2) VERIFYING / INSPECTION RECORDS FOR THE INSPECTION/TEST ACTIVITY
(3) EQUIPMENT SAMPLE SIZE REQUIRED FOR THE INSPECTION/TEST ACTIVITY
QP-022201-03-21
PROPERTY OF
DWN BY
DWN DATE
APVD BY
APVD DATE
SHEET
REVISION
LENA CHNG
3 SEP 2015
TANG NAI AN
3 SEP 2015
5 OF 8
02
QP-022201-03-21
ASSEMBLED EQUIPMENT: API 6A/ ISO 10423 PSL-3, PSL-3G, ALL PRESSURES, ALL TEMPERATURE RATINGS, ALL MATERIAL CLASSES
CUSTOMER
BP (SP-007057)
INSPECTION /
TEST ACTIVITY
HYDROSTATIC SEAT
TEST OF VALVES
(AS APPLICABLE)
STANDARD (1)
API 6A/ ISO 10423
CAMERON BOM
DOC
Y/N(2)
SAMPLE
SIZE (3)
CUSTOMER
INSPECTION
YES
100%
HOLD
YES
100%
HOLD
ACCEPTANCE CRITERIA:
SHALL SHOW NO VISIBLE LEAKAGE UNDER TEST PRESSURE.
REPORT TO INCLUDE ACTUAL TEST PRESSURE, DURATION, START / STOP TIMES.
CUSTOMER
REQUIREMENT
A CHART RECORDER SHALL BE USED ON ALL HYDROSTATIC TESTS. CHARTS SHALL IDENTIFY THE
RECORDING DEVICE UNIQUE IDENTIFIER AND BE SIGNED AND DATED. IF CHARTS RECORDER USED
DURING TESTING IS NOT CALIBRATED, THE TEST CHART SHALL BE MARKED WITH THE STARTING AND
ENDING TEST PRESSURES TAKEN FROM THE CALIBRATED PRESSURE GAGE/TRANSDUCER.
NOTE:
TEST FLUID SHALL BE TREATED WITH RUST PREVENTIVE.
HYDROSTATIC TEST SHALL BE CARRIED OUT PRIOR TO PAINTING OR COATING. IF THE BODIES AND
OTHER PRESSURE CONTAINING PARTS HAVE BEEN MADE OF WROUGHT MATERIAL, TEST MAY BE
COMPLETED AFTER PRIMER LAYERS.
AFTER HYDROSTATIC TESTING, EQUIPMENT SHALL BE VISUALLY INSPECTED FOR MECHANICAL
DAMAGE.
GAS TEST
(AS APPLICABLE)
CUSTOMER
REQUIREMENT
NOTE:
GAS TEST SHALL BE CARRIED OUT PRIOR TO PAINTING OR COATING. IF THE BODIES AND OTHER
PRESSURE CONTAINING PARTS HAVE BEEN MADE OF WROUGHT MATERIAL, TEST MAY BE
COMPLETED AFTER PRIMER LAYERS.
(1) REVISION LEVEL IS CURRENT REVISION UNLESS OTHERWISE NOTED OR NOT COVERED BY API/ ISO.
(2) VERIFYING / INSPECTION RECORDS FOR THE INSPECTION/TEST ACTIVITY
(3) EQUIPMENT SAMPLE SIZE REQUIRED FOR THE INSPECTION/TEST ACTIVITY
QP-022201-03-21
PROPERTY OF
DWN BY
DWN DATE
APVD BY
APVD DATE
SHEET
REVISION
LENA CHNG
3 SEP 2015
TANG NAI AN
3 SEP 2015
6 OF 8
02
QP-022201-03-21
ASSEMBLED EQUIPMENT: API 6A/ ISO 10423 PSL-3, PSL-3G, ALL PRESSURES, ALL TEMPERATURE RATINGS, ALL MATERIAL CLASSES
CUSTOMER
BP (SP-007057)
INSPECTION /
TEST ACTIVITY
STANDARD (1)
MAKE-UP OF
PROPRIETARY
THREAD
(AS APPLICABLE)
DOC
Y/N(2)
SAMPLE
SIZE (3)
CUSTOMER
INSPECTION
YES
100%
HOLD
YES
100%
MONITOR
YES
100%
MONITOR
ACCEPTANCE CRITERIA:
MANDREL MUST PASS COMPLETELY THROUGH VALVE BORE OR VERTICAL BORE, AS APPLICABLE.
CUSTOMER
REQUIREMENT
NOTE:
DRIFT EQUIPMENT USED SHALL NOT BE DETRIMENTAL TO THE PRODUCT BEING TESTED. E.G.
CARBON STEEL DRIFT BARS SHALL NOT BE USED ON CRA BORES.
CAMERON BOM
CUSTOMER
REQUIREMENT
PAINTING
(AS APPLICABLE)
CAMERON BOM
CUSTOMER
REQUIREMENT
VERIFY THAT ASSEMBLIES ARE PAINTED PER BP APPROVED CAMERON PAINT SPECIFICATION AND
FREE OF BLAST MEDIA INGRESS.
NOTE:
EQUIPMENT SHALL BE MASKED TO PREVENT BLASTING MEDIA FROM ENTERING INTO SEALING
AREAS.
IF EQUIPMENT IS REMOVED FROM CONTROLLED PROCEDURES, SURFACE CLEANLINESS AND
OTHER PARAMETERS SPECIFIED IN PAINT SPECIFICATION / PROCEDURES SHALL BE VERIFIED
BEFORE PAINTING.
ACCEPTANCE CRITERIA:
PER CAMERON PAINT SPECIFICATION AND SHALL SHOW NO INGRESS OF BLAST MEDIUM.
(1) REVISION LEVEL IS CURRENT REVISION UNLESS OTHERWISE NOTED OR NOT COVERED BY API/ ISO.
(2) VERIFYING / INSPECTION RECORDS FOR THE INSPECTION/TEST ACTIVITY
(3) EQUIPMENT SAMPLE SIZE REQUIRED FOR THE INSPECTION/TEST ACTIVITY
QP-022201-03-21
PROPERTY OF
DWN BY
DWN DATE
APVD BY
APVD DATE
SHEET
REVISION
LENA CHNG
3 SEP 2015
TANG NAI AN
3 SEP 2015
7 OF 8
02
QP-022201-03-21
ASSEMBLED EQUIPMENT: API 6A/ ISO 10423 PSL-3, PSL-3G, ALL PRESSURES, ALL TEMPERATURE RATINGS, ALL MATERIAL CLASSES
CUSTOMER
BP (SP-007057)
INSPECTION /
TEST ACTIVITY
FINAL VISUAL
INSPECTION
STANDARD (1)
CAMERON
CUSTOMER
REQUIREMENT
DOC
Y/N(2)
SAMPLE
SIZE (3)
CUSTOMER
INSPECTION
YES
100%
HOLD
ACCEPTANCE CRITERIA:
PER CAMERON BOM.
DOCUMENTATION
(AS APPLICABLE)
YES
100%
CUSTOMER
REQUIREMENT
YES
100%
HOLD
(1) REVISION LEVEL IS CURRENT REVISION UNLESS OTHERWISE NOTED OR NOT COVERED BY API/ ISO.
(2) VERIFYING / INSPECTION RECORDS FOR THE INSPECTION/TEST ACTIVITY
(3) EQUIPMENT SAMPLE SIZE REQUIRED FOR THE INSPECTION/TEST ACTIVITY
QP-022201-03-21
PROPERTY OF
DWN BY
DWN DATE
APVD BY
APVD DATE
SHEET
REVISION
LENA CHNG
3 SEP 2015
TANG NAI AN
3 SEP 2015
8 OF 8
02
QP-022201-03-21
ASSEMBLED EQUIPMENT: API 6A/ ISO 10423 PSL-3, PSL-3G, ALL PRESSURES, ALL TEMPERATURE RATINGS, ALL MATERIAL CLASSES
CUSTOMER
BP (SP-007057)
INSPECTION /
TEST ACTIVITY
STANDARD (1)
SAMPLE
SIZE (3)
CUSTOMER
INSPECTION
1. EQUIPMENT SHALL BE DRAINED AND LUBRICATED AFTER TESTING AND PRIOR TO STORAGE OR
SHIPMENT.
NO
100%
2. PRIOR TO SHIPMENT, PARTS SHALL HAVE EXPOSED METALLIC SURFACES PROTECTED WITH A RUST
PREVENTATIVE WHICH WILL NOT BECOME FLUID AND RUN AT A TEMPERATURE LESS THAN 125
DEGREES FAHRENHEIT (52oC).
NO
100%
3. EXPOSED SEALING SURFACES SHALL BE PROTECTED FROM MECHANICAL DAMAGE FOR SHIPPING.
NO
100%
YES
100%
HOLD
DOCUMENTATION
(AS APPLICABLE)
CONTINUED
STORAGE / SHIPPING
(AS APPLICABLE)
DOC
Y/N(2)
CUSTOMER
REQUIREMENT
(1) REVISION LEVEL IS CURRENT REVISION UNLESS OTHERWISE NOTED OR NOT COVERED BY API/ ISO.
(2) VERIFYING / INSPECTION RECORDS FOR THE INSPECTION/TEST ACTIVITY
(3) EQUIPMENT SAMPLE SIZE REQUIRED FOR THE INSPECTION/TEST ACTIVITY
QP-022201-03-21