You are on page 1of 16

Glass Suspension Insulators

ANSI Class

macleanpower.com

GLASS SUSPENSION INSULATOR

Glass Insulators

glass
insulator
production
shop
glass
insulator
production
shop

MacLean
Power
Systems
Glass
insulator
production
shop
produces
high-voltage
Glass
insulator
production
shop
produces
high-voltageoverhead
overheadline
lineinsulators
insulators
of of
various
types
withstanding
mechanical
failing
various types withstanding
mechanical
failingload
loadfrom
from4040kN
kNtoto530
530kN
kN
incompliance
with
thethe
State
and
international
standards
requirements.
incompliance
with
State
and
international
standards
requirements.Toughened
Toughenedoror
MacLean
Power
isinsulating
a leading
manufacturer
ofhas
products
used
by utilities
for
annealed
glass
is used
as as
insulating
material
which
has
a ahigh
properties,
annealed
glass
isSystems
used
material
which
highinsulating
insulating
properties,
mechanical
strength,
thermal
and
chemical
stability.
building
transmission
and
distribution
lines and
substations. MPS product families
mechanical
strength,
thermal
and
chemical
stability.
include hardware and connection products as well as insulation and protection

According
toWith
thethe
customer
requirements
areas
the
high
pollutions,
According
to
customer
requirements
for
areaswith
with
the
highairair
pollutions,
products.
global
raw material
sourcingfor
capabilities,
MPS
produces
over
factory
produces
insulators
using
pins
equipped
with
zinc
sleeves,
being
factory
produces
insulators
using
pins
equipped
with
zinc
sleeves,
beingthe
the
10,000 items in nine manufacturing facilities worldwide. With six production facilities
"sacrificial
electrode"
which
prevent
forfor
a long
"sacrificial
electrode"
which
prevent
a longtime
timethe
thecorrosion
corrosioncaused
causedbybyDC
DC
in the United States, MPS has a highly flexible supply chain which is the foundation
and
thethe
environment.
and
environment.
to the MPS business model which supports local manufacturing for high service

levels,
diversity
development
programs
and
also
sustainability
and green
initiatives.
Thermal
treatment
of of
glass
(hardening)
provides
high
and
electrical
Thermal
treatment
glass
(hardening)
provides
highmechanical
mechanical
and
electrical
properties
thermal
strength
insulator.
Aftersubsequent
subsequentthermal
thermaltests
tests
properties
andand
thermal
strength
ofof
thethe
insulator.
After
defective
items
are
rejected.
It guarantees
specified
characteristics
ofinsulators.
insulators.
defective
items
areSystems
rejected.
It guarantees
specified
characteristics
Maclean
Power
(MPS)
is known the
forthe
years
of quality
products inofthe
Power
Utility Market. Their toughened glass insulators are no exception. Made with quality

After
thermal
tests
all
glass
parts
subjected
the
visual
inspectionand
and
After
thermal
all
glass
parts
areare
subjected
totothe
inspection
materials
and tests
quality
control
standards
that
are unmatched
invisual
the
industry.
verification
dimensions.
verification
of of
dimensions.
With
qualityassembly
products, knowledgeable
people
and amechanical
generous storm
inventory,tests are
After
glass
insulators
routine
andelectrical
electrical
After
thethe
assembly of of
glass
insulators
routine
mechanical and
tests are
MacLean
is
a
great
partner
to
have.
carried
out.
carried out.

In 2007,
Steep
wave
front
(puncture
air)
testswere
werecarried
carriedout
outtotomeet
meetthe
the
In 2007,
Steep
wave
front
(puncture
in in
air)
tests
standard
requirements
of
IEC
61211:2004.
standard requirements of IEC 61211:2004.

Global Insulator Group

LLC Global Insulator Group (GIG) is the company that


ouralsky
Insulators and Fittings Plant)
manages distribution and promotion of products of OAO
Insulators
and Fittings
nd FittingsYuAIZ
Plant(Yuzhnouralsky
was founded
in 1957
and Plant),
now Russia
is an
Lviv Insulator
gy sector, and
uniting
on theCompany
same Ltd.,
areaUkraine.
a fewMentioned
production
producers are the reputable manufacturers of glass and
oduction, ceramic
insulator production, forging and
porcelain insulators, line fittings for overhead transmission lines

and switchgears, stations and substations with voltages from


0.4 kV to 1150
gement system
waskV.established on the factory in
The products gained widespread acceptance in power systems,
and in 2009
its systematical development enabled
railroad facilities, oil and gas industry. More than 300 companies
pliance with
the and
new
version
of and
ISO
9001:2008
from Russia
other
CIS countries
48 countries
in
Middle East,with
Asia-Pacific
Africa
ng centerEurope,
has Latin
an America,
accreditation
theregion,
Federal
are the
regular customers
of Global
Insulator
Group.
ulation and
Metrology,
and
meets
requirements

ard GOST The


R and
the international standard ISO/IEC
companies production quality is confirmed by international
5:2005. quality certificates.
ram in 2006 the new glass furnace was constructed
The quality management system established in the factories
nning of 2008
the WALTEC production line for the
is certified in accordance with the international standard ISO
sulating parts
was put into operation. Today the
9001:2008.
ion process of the enterprise is continuing.
subjected to type and periodical tests in independent
test centres.
Factory
has the possibility to carry out

YuAIZ
to the special requirements of the customers.
Yuzhnouralsky Insulators and Fittings Plant was founded in

and now
is an unique enterprise in the energy sector,
ny Ltd. 1957
("LIC"
Ltd.)
uniting on the same area a few production facilities: glass
ng high-voltage
insulators
made
of production,
toughened
and
insulator production,
ceramic
insulator
forging
and
ed in 1965.
casting workshops.
dernizationIn 1996,
was the
brought
into force at LIC: the new
quality management system was established
nstructed on
and
modern
production
lineand
forin 2009
manuthe a
factory
in accordance
with ISO 9001,
has been itsinstalled.
The
modernization
of
production
systematical development enabled the confirmation
of compliance
with the
new
version of ISO
9001:2008
e efficiency,
increased
the
product
competitiveness
requirements. YuAIZ testing center has an accreditation with
dvanced equipment
WALTEC allowed the company
the Federal Agency for Technical Regulation and Metrology,
according and
to meets
international
requirements standards.
of the Russian State standard GOST
R and the
international standard
17025:2006,Plant
ISO/IEC
of insulators
manufactured
in ISO/IEC
Lviv Insulator
17025:2005.
ty, have been successfully operated on lines with
kV in power
ofprogram
morein 2006
thanthe 40
countries
Within systems
the investment
new glass
proof positive
quality
andInhigh
performfurnaceof
wasperfect
constructed
at the factory.
the beginning
of
2008 the WALTEC production line for the manufacturing
ators.
of glass insulating parts was put into operation. Today the
ting laboratory
certificated
byprocess
Federal
comprehensive
modernization
of the Agency
enterprise ison
continuing.
Metrology
of Ukraine where each batch of the
subjected to acceptance tests.
The production of YuAIZ is subjected to type and periodical
a certifiedtests
quality
management
system
in production
in independent
national and
international
test centers.
Factory has
possibility to carry
out additional
tests according
glass insulators
inthe
accordance
with
ISO 9001:2008.
to the special requirements of the customers.
l location on the border with Europe, numerous
seness to the sea lines allows LIC to supply products
2

certificates

Glass Insulators
HV glass suspension insulator

52-3 Type

High-Voltage Laboratory of KEMA


(the Netherlands)
Type test certificate of complete type test
No. 07-1048
23.07.200714.09.2007
The object has been subjected to the series of
proving tests in accordance with ANSI C 29.2

glass insulators

MG523Z
OAO "YuAIZ"
ANSI C 29.2

52- 3

Part Number
20 .0 0 0 ( 10 0 )
The manuf act urer
lbs ( kN)
10 .0 0 0 ( 50 )
lbs ( kN)

s.

High-Voltage Laboratory of KEMA


(the Netherlands)
Type test certificate of complete type test
No. 07-1035
23.07.200714.09.2007
The object has been
subjected to the series of
MG523Z
proving tests in accordance with ANSI C 29.2
OAO "YuAIZ"

in ( mm) Ref e1r0e3/4


nce(255)
designat ion
3/4
(146)
in ( m m )
5
Combi5/8
ned mechanical & elect rical st rengt h
(320)
in ( m m )
12
Tension proof

t ype B
Shell diamet er dimension, D
kV
130
Unit spacing dimension, H
kV
80
Leakage dist ance
kV
50
Connect ing hardw are coupling
kV
125/ 130
Low - f requency punct ure
kV
10
Low - f requency dry f lashover
V
50
Low - f requency w et f lashover
lb ( kg)
8 .8 ( 4 .0 )
Crit ical impulse f lashover + /

ANSI C 29.2

Low - f requency t est volt age rms t o ground

lb ( kg)

8 .8 ( 4 .0 )

Maximum RIV at 1000 kHz


Weight

52- 3

lbs ( kN)

20 .0 0 0 ( 10 0 )

lbs ( kN)

10 .0 0 0 ( 50 )

in ( m m )

10 3/4 (255)

in ( m m )

53/4 (146)

in ( m m )

125/8 (320)

t ype B

kV

130

kV

80

kV

50

kV

125/ 130

kV
V

10
50

Insulator meet ANSI C 29.1, ANSI C 29.2 requirements.

2014 Copyright MacLean Power Systems


Technical information subject to change without notice

electric characteristics of insulator string

Flashover

HV glass suspension insulator of 523, 525 t ype


Flashover voltages of suspension insulator string with insulators of standard profile are based on the tests according to
ANSI C 29.1.
Characteristics are given for the strings without screens and arcing horns (at application of the specified protective fittings
the characteristics are defined according to the arcing distance specified in the documentation for the string).
Diameter 10 in (255 mm)
Spacing 53/4 in (146 mm)
Number
of insulators
in string, pcs.

Power frequency
flashover voltage, kV

Critical impulse
flashover voltage, kV

dry

wet

Positive
polarity (+)

Negative
polarity ()

145

90

220

225

205

130

315

320

270

170

410

420

325

215

500

510

380

255

595

605

435

295

670

695

485

335

760

780

540

375

845

860

10

590

415

930

945

11

640

455

1015

1025

12

690

490

1105

1105

13

735

525

1185

1190

14

785

565

1265

1275

15

830

600

1345

1360

16

875

635

1425

1440

17

920

670

1505

1530

18

965

705

1585

1615

19

1010

740

1665

1700

20

1050

775

1745

1785

21

1100

810

1825

1870

22

1135

845

1905

1955

23

1180

880

1985

2040

24

1220

915

2065

2125

25

1260

950

2145

2210

26

1300

985

2220

2295

27

1340

1015

2300

2380

28

1380

1045

2375

2465

29

1425

1080

2455

2550

30

1460

1110

2530

2635

Acc. to ANSI C 29.1 there are possible the tolerances in values:


dry power frequency flashover voltage 5% (average flashover value at testing on three strings will be equal or higher than
95% from the value shown in the table),
wet power frequency flashover voltage 10% (average flashover value at testing on three strings will be equal or higher
than 90% from the value shown in the table),
critical impulse flashover voltage 8% (average flashover value at testing on three strings will be equal or higher than 92%
from the value shown in the table).
2014 Copyright MacLean Power Systems
Technical information subject to change without notice

10

certificates

Glass Insulators

HV glass suspension insulator

52-5 Type

High-Voltage Laboratory of KEMA


(the Netherlands)
Type test certificate of complete type test
No. 07-1048
23.07.200714.09.2007
glass insulatorsThe object has been subjected to the series of
proving tests in accordance with ANSI C 29.2

ANSI C 29.2
lbs ( kN)
lbs ( kN)
in ( m m )
in ( m m )
in ( m m )

kV
kV
kV
kV
kV
V
lb ( kg)

HV glass suspension insulator


High-Voltage Laboratory of KEMA
(the Netherlands)
Type test certificate of complete type test
No. 08-1029
10.04.200824.04.2008
The object has been subjected to the series of
proving tests in accordance with ANSI C 29.2

MG525Z
High-Voltage Laboratory of KEMA
(the
OAO
"YuNetherlands)
AIZ"
Type test certificate of complete type test
No.
07-1035
23.07.200714.09.2007
52- 5
The object has been subjected to the series of
in accordance with ANSI C 29.2
30 .0proving
0 0 ( 136tests
)
Part
Number
Th15
e.0m0a0nu( 6
f a8c)t urer
103/4 (255)
Ref e3/4
rence designat ion
(146)
5

MG525Z
OAO "YuAIZ"
ANSI C 29.2

52- 5

C1
o2
m5/8
bin(320)
ed mechanical & elect rical st rengt h
pepJroof
Tenstioyn

lbs ( kN)

30 .0 0 0 ( 136)

lbs ( kN)

15.0 0 0 ( 68 )

Shell d13
ia0met er dimension, D
8
Unit spa0cing dimension, H

in ( m m )

103/4 (255)

in ( m m )

53/4 (146)

in ( m m )

125/8 (320)

Leakag5e0 dist ance


Con1n2e5c/t 1
in3g0 hardw are coupling
Low - f r1e0quency punct ure
Low - f r50
equency dry f lashover
8-.8f re( q
4u
.0e)ncy w et f lashover
Low

t ype J

kV

130

kV

80

kV

50

Crit ical impulse f lashover + /

kV

125/ 130

Low - f requency t est volt age rms t o ground

kV

10

Maximum RIV at 1000 kHz


Weight

50

lb ( kg)

8 .8 ( 4 .0 )

Insulator meet ANSI C 29.1, ANSI C 29.2 requirements.

2014 Copyright MacLean Power Systems


Technical information subject to change without notice

electric characteristics of insulator string

Flashover

HV glass suspension insulator of 523, 525 t ype


Flashover voltages of suspension insulator string with insulators of standard profile are based on the tests according to
ANSI C 29.1.
Characteristics are given for the strings without screens and arcing horns (at application of the specified protective fittings
the characteristics are defined according to the arcing distance specified in the documentation for the string).
Diameter 10 in (255 mm)
Spacing 53/4 in (146 mm)
Number
of insulators
in string, pcs.

Power frequency
flashover voltage, kV

Critical impulse
flashover voltage, kV

dry

wet

Positive
polarity (+)

Negative
polarity ()

145

90

220

225

205

130

315

320

270

170

410

420

325

215

500

510

380

255

595

605

435

295

670

695

485

335

760

780

540

375

845

860

10

590

415

930

945

11

640

455

1015

1025

12

690

490

1105

1105

13

735

525

1185

1190

14

785

565

1265

1275

15

830

600

1345

1360

16

875

635

1425

1440

17

920

670

1505

1530

18

965

705

1585

1615

19

1010

740

1665

1700

20

1050

775

1745

1785

21

1100

810

1825

1870

22

1135

845

1905

1955

23

1180

880

1985

2040

24

1220

915

2065

2125

25

1260

950

2145

2210

26

1300

985

2220

2295

27

1340

1015

2300

2380

28

1380

1045

2375

2465

29

1425

1080

2455

2550

30

1460

1110

2530

2635

Acc. to ANSI C 29.1 there are possible the tolerances in values:


dry power frequency flashover voltage 5% (average flashover value at testing on three strings will be equal or higher than
95% from the value shown in the table),
wet power frequency flashover voltage 10% (average flashover value at testing on three strings will be equal or higher
than 90% from the value shown in the table),
critical impulse flashover voltage 8% (average flashover value at testing on three strings will be equal or higher than 92%
from the value shown in the table).
2014 Copyright MacLean Power Systems
Technical information subject to change without notice

10

Glass Insulators
52-8 Type
glass insulators

High-Voltage Laboratory of KEMA


(the Netherlands)
Type test certificate of complete type test
No. 07-1035
23.07.200714.09.2007
The object has been subjected to the series of
proving tests in accordance with ANSI C 29.2

MG528Z
OAO "YuAIZ"
ANSI C 29.2
lbs ( kN)
lbs ( kN)

52- 8
4 0 .0 0 0 ( 18 0 )
20Part
.0 0 0Number
( 90)

MG528Z

in ( m m )

T1
h1e(m
28a0n)uf act urer

in ( m m )

5 3/4 (146)
Ref erence designat ion
15 ( 38 5)
Cotm
ypbeinKed mechanical & elect rical st rengt h

kV

Ten1s3
io0n proof

kV

Shell8 d
0iamet er dimension, D

in ( m m )

11 ( 28 0 )

kV

Unit5s0pacing dimension, H

in ( m m )

5 3/4 (146)

kV

in ( m m )

15 ( 38 5)

kV

Le
a5
ka
12
/ g13e0dist ance
Conn
10ect ing hardw are coupling

t ype K

Low 50
- f requency punct ure

kV

130

L1o3w
.6- f( r6e.q
2u
) ency dry f lashover
Low - f requency w et f lashover

kV

80

kV

50

Crit ical impulse f lashover + /

kV

125/ 130

Low - f requency t est volt age rms t o ground

kV

10

in ( m m )

lb ( kg)

Maximum RIV at 1000 kHz


Weight

OAO "YuAIZ"
ANSI C 29.2

52- 8

lbs ( kN)

4 0 .0 0 0 ( 18 0 )

lbs ( kN)

20 .0 0 0 ( 90 )

50

lb ( kg)

13.6 ( 6.2)

Insulator meet ANSI C 29.1, ANSI C 29.2 requirements.

2014 Copyright MacLean Power Systems


Technical information subject to change without notice

electric characteristics of insulator string

Flashover

HV glass suspension insulator of 528 t ype


Flashover voltages of suspension insulator string with insulators of standard profile are based on the tests according to
ANSI C 29.1.
Characteristics are given for the strings without screens and arcing horns (at application of the specified protective fittings
the characteristics are defined according to the arcing distance specified in the documentation for the string).
Diameter 11 in (280 mm)
Spacing 53/4 in (146 mm)
Number
of insulators
in string, pcs.

Power frequency
flashover voltage, kV
dry

Critical impulse
flashover voltage, kV

wet

Positive
polarity (+)

Negative
polarity ()

145

90

220

225

205

130

315

320

270

170

410

420

325

215

500

510

380

255

595

605

435

295

670

695

485

335

760

780

540

375

845

860

10

590

415

930

945

11

640

455

1015

1025

12

690

490

1105

1105

13

735

525

1185

1190

14

785

565

1265

1275

15

830

600

1345

1360

16

875

635

1425

1440

17

920

670

1505

1530

18

965

705

1585

1615

19

1010

740

1665

1700

20

1050

775

1745

1785

21

1100

810

1825

1870

22

1135

845

1905

1955

23

1180

880

1985

2040

24

1220

915

2065

2125

25

1260

950

2145

2210

26

1300

985

2220

2295

27

1340

1015

2300

2380

28

1380

1045

2375

2465

29

1425

1080

2455

2550

30

1460

1110

2530

2635

Acc. to ANSI C 29.1 there are possible the tolerances in values:


dry power frequency flashover voltage 5% (average flashover value at testing on three strings will be equal or higher than
95% from the value shown in the table),
wet power frequency flashover voltage 10% (average flashover value at testing on three strings will be equal or higher
than 90% from the value shown in the table),
critical impulse flashover voltage 8% (average flashover value at testing on three strings will be equal or higher than 92%
from the value shown in the table).
2014 Copyright MacLean Power Systems
Technical information subject to change without notice

11

Glass Insulators
52-11 Type
glass insulators
glass insulators

High-Voltage
High-Voltage Laboratory
Laboratory of
of EGU
KEMA
Netherlands)
(the Czech
Republic - Prague)
Type test certificate of complete type test
Type
No. 07-1035
07-1035 28.01.2014
23.07.200714.09.2007
No.
The object has been subjected to the series of
The object has been subjected to the series of
proving tests in accordance with ANSI C 29.2
proving tests in accordance with ANSI C 29.2

MG528Z
OAO "YuAIZ"
ANSI C 29.2
lbs ( kN)
lbs ( kN)
in ( m m )
in ( m m )
in ( m m )

kV
kV
kV
kV
kV
V
lb ( kg)

52- 8
4 0 .Number
0 0 0 ( 18 0 )
Part
2
0
.
) rer
The m0a0n0uf(a9c0t u
Part Number
11 ( 28 0 )
enm
ctnuarteio
rn
Re fTehr3/4
ceanduefsaig
(146)
5
8c5me)edce
edn
CoR
m1eb5fie
n(re3
hsaingincatl io&n elect rical s trengt h
t
y
p
e
K
Tension proof
Combined mechanical & elect rical s trengt h
0et er dimension, D
Shell di1a3m
Tension proof
8
0
Unit spacing dimension, H
Shell diamet er dimension, D
Leakage50dis tance
Unit spacing dimension, H
Conn1e2c5t/in13
g0hardw are coupling
Leakage dis tance
1
0
Low - f requency punct ure
Connect ing hardw are coupling
Low - f re50
quency dry f lashover
Low - f requency punct ure
1
3
.
6
Low - f req(u6e.2n)cy w et f lashover
Low - f requency dry f lashover
Crit ical impulse f lashover + /
Low - f requency w et f lashover
Low - f requency t est volt age rms t o ground
Crit ical impulse f lashover + /
Maximum RIV at 1000 kHz
Low - f requency t est volt age rms t o ground
Weight
Maximum RIV at 1000 kHz
Insulator
Weightmeet ANSI C 29.1, ANSI C 29.2 requirements.

MG5211Z
OAO "YuAIZ"
MG5211Z
ANSI C 29.2
ANSlbI sC(2k9N.)2
lbs ( kN)
lbs ( kN)
in ( m m )
lbs ( kN)
in ( m m )
in ( m m )
in ( m m )
in ( m m )

in ( m m )
kV

kV
kV
kV
kV
kV
kV
kV
kV
V
kV
lb ( kg)
V
lb ( kg)

OAO
52- 11"YuAIZ"
50 .0 0 05(22-211
2)
25.0 0 0 ( 111)
50 .0 0 0 ( 222)
11 ( 28 0 )
25.0 0 0 ( 111)
6 1/8 (156)
11 ( 28 0 )
165/6 (428)
6 1/8 (156)
t ype K
165/6 (428)
130
t ype K
80
130
50
80
14 0 / 14 0
50
10
14 0 / 14 0
50
10
17.4 ( 7.9)
50
17.4 ( 7.9)

Insulator meet ANSI C 29.1, ANSI C 29.2 requirements.

2014 Copyright MacLean Power Systems


Technical information subject to change without notice

electric characteristics of insulator string

Flashover

HV glass suspension insulator of 5211 t ype


Flashover voltages of suspension insulator string with insulators of standard profile are based on the tests according to
ANSI C 29.1.
Characteristics are given for the strings without screens and arcing horns (at application of the specified protective fittings
the characteristics are defined according to the arcing distance specified in the documentation for the string).
Diameter 11 in (280 mm)
Spacing 61/8 in (156 mm)
Number
of insulators
in string, pcs.

Power frequency
flashover voltage, kV
dry

Critical impulse
flashover voltage, kV

wet

Positive
polarity (+)

Negative
polarity ()

145

90

220

225

205

130

315

320

270

170

410

420

345

225

520

530

400

275

615

625

455

315

690

715

510

360

765

815

570

405

920

925

10

640

455

1015

1025

11

690

490

1105

1105

12

735

525

1185

1190

13

785

565

1265

1275

14

830

600

1345

1360

15

875

635

1425

1440

16

920

670

1505

1530

17

965

705

1585

1615

18

1010

740

1665

1700

19

1050

775

1745

1785

20

1100

810

1825

1870

21

1135

845

1905

1955

22

1180

880

1985

2040

23

1220

915

2065

2125

24

1260

950

2145

2210

25

1300

985

2220

2295

26

1340

1015

2300

2380

27

1380

1045

2375

2465

28

1425

1080

2455

2550

29

1460

1110

2530

2635

30

1495

1140

2605

2720

Acc. to ANSI C 29.1 there are possible the tolerances in values:


dry power frequency flashover voltage 5% (average flashover value at testing on three strings will be equal or higher than
95% from the value shown in the table),
wet power frequency flashover voltage 10% (average flashover value at testing on three strings will be equal or higher
than 90% from the value shown in the table),
critical impulse flashover voltage 8% (average flashover value at testing on three strings will be equal or higher than 92%
from the value shown in the table).
2014 Copyright MacLean Power Systems
Technical information subject to change without notice

12

10

Accessories and Features

glass insulators

Locking Devices
The plant manufactures insulators with W-clips and split-pins, which corresponds to the Russian and international standards.
Split-pin provides more reliable coupling in a string, as the cross-section area of the split-pin is 2 times more than the crosssection area of the W-clip. The insertion of split-pins and bending of the legs are made at the plant.
It is necessary to note, that with such a universal coupling it is possible to make a string of insulator units with different types
of locking devices.
Insulator with W-clip

Insulator with split-pin

Zinc Sleeves
The characteristics of insulators with a zinc sleeve fully correspond to those of
insulators without it. The zinc sleeve, being "a sacrificial electrode", prevents for
a long time from corrosion of a pin caused by d.c. and environmental conditions
(a tropical climate).
1. Cap.
2. Locking device (split-pin).
3. Glass part.
4. Gasket.
5. Pin.
6. Binding material.
7. Zinc sleeve.

When the insulators are stored in a dry atmosphere, especially at high temperature,
the cement bond loses its moisture. It resulted in a slight shrinkage, in this case
increases the clearance between the glass and cement bond. In some cases the
increased clearance can lead to a rotation of the pin relative to the glass by a
few degrees. This rotation arises from the manual effort with characteristic clicking
noise. This phenomenon disappears once you move the insulator into the atmosphere
with normal conditions or being under load when assembling on the line. This
phenomenon does not affect an insulator performance.

11

2014 Copyright MacLean Power Systems


Technical information subject to change without notice

packing
Packing

Packet with Crates

Each packet with crates includes several


wooden crates placed on the pallet.
For packing manufacture the "screwringed" nails are used. They have ring
grooves on the stem that create the additional friction force and the nails keep
the nailed timber more fixedly.
The pallet packer wraps round the packet
with insulators by strechtape in a few
layers to strengthen it for transport to
the consumer.

Slat and Wire Package

Sea Packet (SP)

Universal Package (UP)

Wooden Crate

The pallet packer wraps round the packet


with insulators by strechtape in a few
layers to strengthen it for transport to
the consumer.

Package with Boxes (PB)

Slatted Crate

Wooden Cylindrical Crate

The advantages of this type of slatted


crate:
Convenience of disassambly (box does
not require special tools to open it: only
untwist the wire and box is opened).
During transportation empty boxes laid
out in crate and to take up a little space
in the truck.

The packing of insulators supplied by GIG is made of wood treated in accordance with the international standard ISPM-15.
When the insulators are stored at the open storage ground, the wood may darken under ultraviolet exploration or dust.
The impact of these factors on the packaging material does not reduce its mechanical strength.
2014 Copyright MacLean Power Systems
Technical information subject to change without notice

12

map of deliveries
Map
of Deliveries

Afghanistan
Albania
Algeria
Angola
Argentina
Austria
Belgium
Bolivia
Bosnia and Herzegovina
Bulgaria
Cameroon
Canada
Chile
China
CIS Countries
Armenia
Azerbaijan
Belarus
Kazakhstan
Kyrgyzstan
Moldova
Tajikistan
Turkmenistan
Ukraine
Uzbekistan

Colombia
Costa Rica
Cote d'Ivoire
Croatia
Cuba
Czechia
Denmark
Estonia
Finland
France
Germany
Great Britain
Guatemala
Hungary
Iceland
Iran
Iraq
Italy
Latvia
Lebanon
Lithuania
Macedonia
Mali
Morocco

Nigeria
Norway
Palestin
Peru
Poland
Portugal
Romania
Senegal
Serbia
Slovakia
Slovenia
South Africa
Spain
Sri Lanka
Syria
Sweden
Tanzania
Turkey
Vietnam

15

13

2014 Copyright MacLean Power Systems


Technical information subject to change without notice

Notes

2014 Copyright MacLean Power Systems


Technical information subject to change without notice

14

Other Quality MacLean Products


Anchoring Systems
Surge Arresters
Conductor Hardware
Cutouts
Crossarms
Grounding and Tools
Insulator Systems
Pole Line Hardware
Formed Wire
Aluminum Mounts
Telecommunications Hardware
Enclosures and Mounts

MacLean Power Systems


481 Munn Road, Suite 300
Fort Mill, SC 29715 USA
fax 803.396.8601
macleanpower.com

Customer Service 1.800.MPS.SHIP


info@macleanpower.com

Copyright 2014 MacLean Power Systems


LBGLAT.03.14

You might also like