You are on page 1of 1

Unit B Grovelands Estate, Longford Road, Exhall, Coventry CV7 9ND

Tel: +44 (0)24 7664 5999 | Fax: +44 (0)24 7664 4081
E-mail: ppickering@coventrytoolholders.co.uk | Web: www.ctl-centreline.com
A Member of Coventry Engineering Group

PITCH CIRCLE CHORDAL DISTANCE CALCULATION


T

To obtain the chordal distance T the following formula is used:


T=DxC
where: D = diameter of the pitch circle
C = constant as given in tables

Number of
Holes

Constant
C

Number of
Holes

Constant
C

Number of
Holes

Constant
C

Number of
Holes

Constant
C

0.86603

10

0.30902

17

0.18375

24

0.13053

0.70711

11

0.28173

18

0.17365

25

0.12533

0.58779

12

0.25882

19

0.16459

26

0.12054

0.50000

13

0.23932

20

0.15643

27

0.11609

0.43388

14

0.22252

21

0.14904

28

0.11196

0.38268

15

0.20791

22

0.14231

29

0.10812

0.34202

16

0.19509

23

0.13617

30

0.10453

You might also like