You are on page 1of 40

SOLID STATE SIGNALLING RELAYS & PLUGBOARDS

CATALOGUE

CORPORATE STATEMENT
FROM DAVID STUCKEY
Introducing increased safety, reliability and time
saving all in one newly engineered breakthrough, the
SELECTiQ.
SELECTiQ is the worlds first digital signalling
relay, developed by the Selectrail team. Selectrail
continue to push the boundaries of rail engineering:
developing, designing and bringing SELECTiQ,
a digital signalling relay to the Australian and
international markets.
This world leading innovation combines traditional
Q-signalling technology with digital confidence,
bringing an improved signalling relay to the market.
Selectrail continually innovate to evolve our product
offerings, and we are very proud of the new
SELECTiQ. Our team have worked tirelessly to bring
this new innovation to the rail industry, focusing
on user safety. Our philosophy has always been to
provide the safest technology to the market, and in
order to continue delivering safety assurance, we
have developed the safest signalling relay on the
market yet.
The SELECTiQ delivers the best equipment
technology in the field and complies with state
of the art safety requirements. Replacing the
traditional electromechanical systems used in
existing technology, the SELECTiQ utilises a digital

system and is therefore able to run for longer, more


accurately and consistently.
The SELECTiQ doesnt just stop there. The digital
system is able to be closely monitored and therefore
runs at increased efficiency. Also with a longer
lifespan, the SELECTiQ requires less maintenance.
Unlike traditional electromechanical relays, no
cleaning of contacts is required EVER!
Safety is of paramount importance to us, therefore
a large amount of research is conducted by the
Selectrail team to ensure the products we provide
adhere to the companys stringent safety standards.
The SELECTiQ signaling relay is of the highest
quality, ensured by Selectrails famous 100% test and
inspection regime conducted at the purpose built
testing facility.

David Stuckey
Managing Director

Please note: Selectrail reserves the right to alter information contained within this document without notice
Selectrail (Australia) Pty Ltd

CONTENTS
TECHNICAL DATA
iQBA1
iQBBA1& iQBBA2
iQBCA1
iQDU9
iQFEX
iQECR1 & iQECR2
iQECX
iQL1
iQN1
iQNA1
iQNHX1
iQNHXC1
iQNN1
iQNNA1
iQS2 & iQS3
iQSA3
iQSELECT1
iQSELECT2
iQSELECT3
iQSPA1
iQSRA1
iQT1 & iQT2
iQTA2
iQUCX1 & iQUCX2
PLUGBOARD
RETAINING CLIP

2
6
7
8
9
10
12
13
14
15
16
17
18
19
20
21
22
23
25
29
30
31
32
33
34
35
36

Please note: Selectrail reserves the right to alter information contained within this document without notice
Selectrail (Australia) Pty Ltd

2016.04.18

WWW. SELECTRAIL.COM

TECHNICAL
DATA

FEATURE 1
Safety integrity level
SIL4 compliant*

The
has been designed
to improve reliability, performance
and functionality over its
electromechanical predecessors
Incorporating customer feedback, the SELECTiQ has
been designed to provide everything required to bring
projects to market in a timely an cost-effective manner.

FEATURES













Reduced maintenace requirements


Reduced lead time
100% solid state technology
No more contact resistance issues
Temperature stability
No moving parts
Backward and upward compatibility with
existing analogue relays
SIL4 compliant*
Accurate and consistent repeatability
User friendly operational display
Improved PIN code retaining plate design
Longer life
Increased reliability
Patent applied for

FEATURE 2
The SELECTiQ is controlled by two synchronized
microcontrollers. Both microcontrollers must agree
before the relay can change from its default (safe)
state.

FEATURE 3
Improved PIN code retaining plate design

* Front contacts only in accordance with railway signalling rules.


2

Please note: Selectrail reserves the right to alter information contained within this document without notice
Selectrail (Australia) Pty Ltd

TECHNICAL
DATA
FEATURE 8

SPECIFICATIONS

User friendly interface provides


indications of voltages present at the
plugboard interface on a 4x4 LED array
as well as activation levels and timing

Nominal Supply Voltage: 12V, 24V,


50V
Output Current: 3.4A/channel @200C
Weight: 500gm
AC Immunity: 1000VAC
EMI/EMC: EN61000, RSS210, Part
15 FCC
Operating Temperature: -400C +850C
Storage Temperature: -550C +1500C
Power Consumption: 500mW
Watchdog Timer
Clock Speed 4MHz
Overvoltage/& Overcurrent Protection
Contact Resistance: <50m
Reverse Polarity

FEATURE 7
Building upon the existing BR930
Q style platform enables retrofitting
to existing relay installations

FEATURE 6

FEATURE 4
10 bit analogue to digital converters
accurately detect the applied control
voltage, providing precise, clearly defined
and highly repeatable control.

100% solid state technology. No more contact


resistance issues, no moving parts, high temperature
stability, accurate and consistent repeatability,
backward and upward compatible with existing
electromechanical relays

FEATURE 5
Contact feet made from new updated material. Also found
in military and aerospace industries. Providing greater
spring resiliance, greater strength and conductivity.

Please note: Selectrail reserves the right to alter information contained within this document without notice
Selectrail (Australia) Pty Ltd

TECHNICAL
DATA
Display Module

System Module

Retaining Clip

Stack C Module

Seal
Nut
Washer

Stack B Module

Handle
Seal

Stack D Module

Stack A Module
Polycarbonate Cover
Power Module

Configuration Module

Base Module

Support Bracket

Coding Pins

Retaining Plate (Improved Design)

Screw
Seal
Relay

Plugboard

Please note: Selectrail reserves the right to alter information contained within this document without notice
Selectrail (Australia) Pty Ltd

TECHNICAL
DATA

6
56

67

56

120

47
67

47
120

28

117

126

N
Q

C
G

D
H
K

178

Both microcontrollers must agree


before the relay may change from
its default (safe) state. The applied
control voltage is accurately detected
by 10 bit on-board analogue-to-digital
converters providing precise, clearly
defined and highly repeatable control of
a relay operation under all anticipated
environmental conditions, effectively
eliminating the variability inherent in coil
operated relays.
Power supply status LEDs indicate
when the applied voltage reaches the
Activation Voltage, providing the signal
technician the ability to detect power
supply problems elsewhere in the signal
box.

14

Operation is controlled by two


synchronised, watchdog equipped
microcontrollers with brownout
detection which are programmed to
emulate conventional relays making the
SELECTiQ a drop-in replacement for
their electromechanical predecessor.

16

16

178

CHARACTERISTIC:

The microcontrollers also detect


the presence of voltage at each of
plugboard connection and display the
result on a 4x4 array of bicolour LEDs.
This arrangement provides the signal
technician with the ability to detect
many external defects such as broken
or short circuited cables.

56

Please note: Selectrail reserves the right to alter information contained within this document without notice
Selectrail (Australia) Pty Ltd

iQBA1

CONTACT LAYOUT :
Note : Layouts shown are when viewed from the rear of the
relay.

DC biased
AC immune
Patent applied for
SIL4 compliant*

* Front contacts only in accordance with railway signalling rules.

Product code

Nominal
working
volt

Contacts

Max full
operating
volts

Minimum
release
volts

PIN code

iQBA1-12F-4B-50

50

12F 4B

40V

7.5V

ACDFH

iQBA1-8F-8B-50

50

8F 8B

40V

7.5V

ACDGH

iQBA1-12F-4B-24

24

12F 4B

19.2V

3.6V

ABFGH

iQBA1-8F-8B-24

24

8F 8B

19.2V

3.6V

ACDEH

iQBA1-12F-4B-12

12

12F 4B

9.6V

1.8V

ABDGS

iQBA1-8F-8B-12

12

8F 8B

9.6V

1.8V

ABDJS

Please note: Selectrail reserves the right to alter information contained within this document without notice
Selectrail (Australia) Pty Ltd

CONTACT LAYOUT :
Note : Layouts shown are when viewed from the rear of the
relay.

iQBBA1&
iQBBA2

DC biased
AC immune
Twin relay
Patent applied for
SIL4 compliant*

* Front contacts only in accordance with railway signalling rules.

Nominal
working
volt

Contacts

Max full
operating
volts

Minimum
release
volts

PIN code

iQBBA1-12F-4B-50

50

2x(6F 2B)

40V

7.5V

ABFHJ

iQBBA1-8F-8B-50

50

2x(4F 4B)

40V

7.5V

ABCEH

iQBBA1-12F-4B-24

24

2x(6F 2B)

19.2V

3.6V

ACEGK

iQBBA1-8F-8B-24

24

2x(4F 4B)

19.2V

3.6V

ACEFK

iQBBA1-4F-2B-14

14

2x(2F 1B)

12V

1.5V

BEFGT

iQBBA1-12F-4B-12

12

2x(6F 2B)

9.6V

1.8V

BEFGX

iQBBA1-8F-8B-12

12

2x(4F 4B)

9.6V

1.8V

ABDKS

iQBBA2-4F-4B-50

50

2x(2F 2B)

40V

7.5V

BFGJK

Product code

Please note: Selectrail reserves the right to alter information contained within this document without notice
Selectrail (Australia) Pty Ltd

iQBCA1

CONTACT LAYOUT :
Note : Layouts shown are when viewed from the rear of the
relay.

DC biased
AC immune
Contactor style
Patent applied for
SIL4 compliant*

* Front contacts only in accordance with railway signalling rules.

Nominal
working
volt

Contacts

Max full
operating
volts

Minimum
release
volts

PIN code

iQBCA1-2FHD-4B-50

50

2F(HD) 4B

40V

7.5V

BCFHK

iQBCA1-2FHD-2F-4B-50

50

2F(HD) 2F 4B

40V

7.5V

BCEKX

iQBCA1-2FHD-4F-4B-50

50

2F(HD) 4F 4B

40V

7.5V

BEGHJ

iQBCA1-2FHD-4B-24

24

2F(HD) 4B

19.2V

3.6V

BCEJK

iQBCA1-2FHD-2F-4B-24

24

2F(HD) 2F 4B

19.2V

3.6V

DEHJX

iQBCA1-2FHD-4F-4B-24

24

2F(HD) 4F 4B

19.2V

3.6V

BEFHJ

iQBCA1-2FHD-4F-4B-12

12

2F(HD) 4F 4B

9.6V

1.8V

ABCKS

Product code

Please note: Selectrail reserves the right to alter information contained within this document without notice
Selectrail (Australia) Pty Ltd

iQDU9

CONFIGURATION

CHARACTERISTIC:
The iQDU9 is a relay housing based on
the iQFE concept. Utilizing 16 diodes,
the iQDU9 is used to block back feeds
in circuits.
FEATURES:
Simplifies fine tuning of signalling
design
Field replaceable
Simplified field installation
More robust than other techniques
Eliminates practice of adding
components to plugboards
Improves design documentation
integrity
SPECIFICATION:
PCB Construction : 2 layer FR4
1.6mm
PCB Dimensions : 107.44mm x
44.45mm
Flame rating (as supplied) : 94V0
Finish : ENIG (gold)
Traces : 2 oz copper, 0.6mm track
width
Maximum current : 2.73A @250C
POWER loss : 3.13mW/mm

Product Code
iQDU9

PIN code
ABEGHJ

Please note: Selectrail reserves the right to alter information contained within this document without notice
Selectrail (Australia) Pty Ltd

iQFEX
CHARACTERISTIC:
The iQFEX (Field Engineering) unit is
a user modifiable platform contained
within a standard miniature Q style
enclosure which provides the signal
engineer with the ability to add various
discrete electronic components into
their overall signalling circuitry in order
to fine tune their design.
FEATURES:
Simplifies fine tuning of signalling
design
Field replaceable
Simplified field installation
More robust than other techniques
Eliminates practice of adding
components to plugboards
Improves design documentation
integrity
SPECIFICATION:
PCB Construction : 2 layer FR4
1.6mm
PCB Dimensions : 107.44mm x
44.45mm
Flame rating (as supplied) : 94V0
Finish : ENIG (gold)
Traces : 2 oz copper, 0.6mm track
width
Maximum current : 2.73A @250C
POWER loss : 3.13mW/mm

10

Model

FE boards

iQFE1

iQFE2

iQFE3

iQFE4

iQFE5

iQFE6

iQFE7

Please note: Selectrail reserves the right to alter information contained within this document without notice
Selectrail (Australia) Pty Ltd

CHARACTERISTIC:
The iQFEX (Field Engineering) unit is a user modifiable platform contained within a standard miniature
Q style enclosure which provides the signal engineer with the ability to add various discrete electronic
components into their overall signalling circuitry in order to fine tune their design.
Up to 7 individual PCBs are stacked inside a convenient an familiar Q style enclosure with each PCB
providing access to every plugboard interconnection A1 through D8 as well as R1 through R4. Two
plated though-hole vias (1mm & 1.5 mm dia.) are provided on each PCB for each plugboard connection,
allowing the addition of various comminations of jumpers, resistors, capasitors, diodes, or other devices
as required.
iQFEX units can be ordered as iQFEX1 (single FE in Q style enclosure) through to iQFE7 (7 FE boards in
Q style enclosure). FE boards are also available separately.
Test point on the topmost board enables the quick connection of an oscilloscope, voltmeter or other
instrument. Each trace on the PCB is sized to carry 2.73A
iQFEX units are shiped without coding pins.
Selectrail assumes no responsibility for its application.
CONFIGURATION
Plugboard

FE1

FE2

FE3

FE4

FE5

FE6

FE7

A
1
2
3
4
5
6
7
8

A
1
2
3
4
5
6
7
8

A
1
2
3
4
5
6
7
8

A
1
2
3
4
5
6
7
8

A
1
2
3
4
5
6
7
8

A
1
2
3
4
5
6
7
8

A
1
2
3
4
5
6
7
8

A
1
2
3
4
5
6
7
8

R1

R1

R1

R1

R1

R1

R1

R1

R3

R3

R3

R3

R3

R3

R3

R3

B
1
2
3
4
5
6
7
8
C
1
2
3
4
5
6
7
8
D
1
2
3
4
5
6
7
8

B
1
2
3
4
5
6
7
8
C
1
2
3
4
5
6
7
8
D
1
2
3
4
5
6
7
8

B
1
2
3
4
5
6
7
8
C
1
2
3
4
5
6
7
8
D
1
2
3
4
5
6
7
8

B
1
2
3
4
5
6
7
8
C
1
2
3
4
5
6
7
8
D
1
2
3
4
5
6
7
8

B
1
2
3
4
5
6
7
8
C
1
2
3
4
5
6
7
8
D
1
2
3
4
5
6
7
8

B
1
2
3
4
5
6
7
8
C
1
2
3
4
5
6
7
8
D
1
2
3
4
5
6
7
8

B
1
2
3
4
5
6
7
8
C
1
2
3
4
5
6
7
8
D
1
2
3
4
5
6
7
8

B
1
2
3
4
5
6
7
8
C
1
2
3
4
5
6
7
8
D
1
2
3
4
5
6
7
8

R2

R2

R2

R2

R2

R2

R2

R2

R4

R4

R4

R4

R4

R4

R4

R4

Please note: Selectrail reserves the right to alter information contained within this document without notice
Selectrail (Australia) Pty Ltd

11

iQECR1 &
iQECR2

CONTACT LAYOUT :
Note : Layouts shown are when viewed from the rear of the
relay.

DC current operated
Lamp proving
iQERC1 suits 110VDC/ 33W
triple pole signal lamp
iQERC2 suits 110VDC/ 12W LED
signal lamp
Patent applied for
SIL4 compliant*

* Front contacts only in accordance with railway signalling rules.

Product code

iQECR1-4F-4B-110
iQECR2-4F-4B-110

12

Rated Contacts Max full Min Rel.


amps
Op. mA
mA
dc
0.4
0.2

4F 4B
4F 4B

220
80

50
55

Interruption time
ms

at mA

100

250

150

350

100

132

PIN code

CFKMX
ABDHJ

Please note: Selectrail reserves the right to alter information contained within this document without notice
Selectrail (Australia) Pty Ltd

iQECX

CONTACT LAYOUT :
Note : Layouts shown are when viewed from the rear of the
relay.

AC current operated
Lamp proving
Patent applied for
SIL4 compliant*

* Front contacts only in accordance with railway signalling rules.

Product code

iQECX1-4F
iQECX1-4F-2B

Rated Contacts Max full Min Rel. Interruption time PIN code
amps
Op. mA
mA
ms at mA
dc
0.4
0.4

4F
4F 2B

180
180

110
110

100

180

200

250

100

180

200

250

Application

ABCDK

SL 35/34/lamp

ABCDK

SL 35/34/lamp

iQECX3-4F

1.0

4F

970

720

ADFHJ

PLJI

iQECX13-4F

0.4

4F

225

120

100

220

DFJKX

SL 17 & 21 ON

iQECX14-4F-4B

0.65

4F 4B

220

70

100

220

ACDFS

SL 17 & 21 OFF

iQECX20-4F-2B

0.22

4F 2B

45

20

iQECX61-4F-4B

0.3

4F 4B

180

72

iQECX62-4F-2B

0.22

4F 2B

60

30

SBDFJ
100

Please note: Selectrail reserves the right to alter information contained within this document without notice
Selectrail (Australia) Pty Ltd

250

ABDHK

LED signal

ALMST

Lamp

13

iQL1

CONTACT LAYOUT :
Note : Layouts shown are when viewed from the rear of the
relay.

DC latched line type


Operate + release circuits
Patent applied for
SIL4 compliant*

Please note : must provide constant


power to C contacts

* Front contacts only in accordance with railway signalling rules.

Product code

Nominal
working
volt

Contacts

Max full
operating
volts

Minimum
release
volts

PIN code

iQL1-11F-4B-50

50

11F 4B

40V

20V

ABEFGW

iQL1-8F-6B-50

50

8F 6B

40V

20V

ABCFGW

iQL1-11F-4B-24

24

11F 4B

19.2V

9.6V

ABDEGW

iQL1-8F-6B-24

24

8F 6B

19.2V

9.6V

ABCEGW

iQL1-11F-4B-12

12

11F 4B

9.6V

4.8V

BDGJXW

iQL1-8F-6B-12

12

8F 6B

9.6V

4.8V

BDGKXW

14

Please note: Selectrail reserves the right to alter information contained within this document without notice
Selectrail (Australia) Pty Ltd

CONTACT LAYOUT :
Note : Layouts shown are when viewed from the rear of the
relay.

iQN1

DC neutral
Line type
Patent applied for
SIL4 compliant*

* Front contacts only in accordance


with railway signalling rules.

Product code

Nominal
working
volt

Contacts

Max full
operating
volts

Minimum
release
volts

PIN code

iQN1-12F-4B-50

50

12F 4B

40V

7.5V

ABCEF

iQN1-8F-8B-50

50

8F 8B

40V

7.5V

ABDEF

iQN1-8F-4B-50

50

8F 4B

40V

7.5V

ABCEF

iQN1-6F-6B-50

50

6F 6B

40V

7.5V

ABDEF

iQN1-4F-4B-50

50

4F 4B

40V

7.5V

ABDEF

iQN1-12F-4B-24

24

12F 4B

19.2V

3.6V

ABCDE

iQN1-8F-8B-24

24

8F 8B

19.2V

3.6V

ABCDF

iQN1-8F-4B-24

24

8F 4B

19.2V

3.6V

ABCDE

iQN1-6F-6B-24

24

6F 6B

19.2V

3.6V

ABCDF

iQN1-4F-4B-24

24

4F 4B

19.2V

3.6V

ABCDF

iQN1-12F-4B-12

12

12F 4B

9.6V

1.8V

ACFJX

iQN1-8F-8B-12

12

8F 8B

9.6V

1.8V

ABCFX

iQN1-8F-4B-12

12

8F 4B

9.6V

1.8V

ACFJX

iQN1-6F-6B-12

12

6F 6B

9.6V

1.8V

ABHJX

iQN1-4F-4B-12

12

4F 4B

9.6V

1.8V

ADFHK

Please note: Selectrail reserves the right to alter information contained within this document without notice
Selectrail (Australia) Pty Ltd

15

iQNA1

CONTACT LAYOUT :
Note : Layouts shown are when viewed from the rear of the
relay.

DC neutral
AC immune
Patent applied for
SIL4 compliant*

* Front contacts only in accordance with railway signalling rules.

Nominal
working
volt

Contacts

Max full
operating
volts

Minimum
release
volts

PIN code

iQNA1-12F-4B-50

50

12F 4B

40V

7.5V

ABEFH

iQNA1-8F-8B-50

50

8F 8B

40V

7.5V

ABEGH

iQNA1-12F-4B-24

24

12F 4B

19.2V

3.6V

ABDFH

iQNA1-8F-8B-24

24

8F 8B

19.2V

3.6V

ABDGH

iQNA1-12F-4B-12

12

12F 4B

9.6V

1.8V

EFGKX

iQNA1-8F-8B-12

12

8F 8B

9.6V

1.8V

EFGJX

Product code

16

Please note: Selectrail reserves the right to alter information contained within this document without notice
Selectrail (Australia) Pty Ltd

CONTACT LAYOUT :
Note : Layouts shown are when viewed from the rear of the
relay.

iQNHX1

AC type
110VAC
Patent applied for
SIL4 compliant*

* Front contacts only in accordance with railway signalling rules.

Product code

Nominal
working
volt

Contacts

Max full
operating
volts

Minimum
release
volts

PIN code

iQNHX1-8F-4B-110

110 AC

8F 4B

90V

30V

ACEFH

Please note: Selectrail reserves the right to alter information contained within this document without notice
Selectrail (Australia) Pty Ltd

17

iQNHXC1

CONTACT LAYOUT :
Note : Layouts shown are when viewed from the rear of the
relay.

AC Type
Contactor style
Patent applied for
SIL4 compliant*

* Front contacts only in accordance with railway signalling rules.

Product code

Nominal
working
volt

Contacts

Max full
operating
volts

Minimum
release
volts

PIN code

iQNHXC1-2FHD-4F-4B-110

110 AC 2F(HD) 4F 4B

90V

30V

ADGKS

18

Please note: Selectrail reserves the right to alter information contained within this document without notice
Selectrail (Australia) Pty Ltd

CONTACT LAYOUT :
Note : Layouts shown are when viewed from the rear of the
relay.

iQNN1

DC neutral
Twin relay
Patent applied for
SIL4 compliant*

* Front contacts only in accordance with railway signalling rules.

Product code

Nominal
working
volt

Contacts

Max full
operating
volts

Minimum
release
volts

PIN code

iQNN1-12F-4B-50

50

2x(6F 2B)

40V

7.5V

CDEFK

iQNN1-8F-8B-50

50

2x(4F 4B)

40V

7.5V

CFGHJ

iQNN1-4F-4B-50

50

2x(2F 2B)

40V

7.5V

CFGHJ

iQNN1-12F-4B-24

24

2x(6F 2B)

19.2V

3.6V

ACDEK

iQNN1-8F-8B-24

24

2x(4F 4B)

19.2V

3.6V

ACEHJ

iQNN1-4F-4B-24

24

2x(2F 2B)

19.2V

3.6V

ACEHJ

iQNN1-12F-4B-12

12

2x(6F 2B)

9.6V

1.8V

BDHKX

iQNN1-8F-8B-12

12

2x(4F 4B)

9.6V

1.8V

BFGKX

Please note: Selectrail reserves the right to alter information contained within this document without notice
Selectrail (Australia) Pty Ltd

19

iQNNA1




CONTACT LAYOUT :
Note : Layouts shown are when viewed from the rear of the
relay.

AC immune
DC biased
Twin relay
Patent applied for
SIL4 compliant*

* Front contacts only in accordance with railway signalling rules.

Product code

Nominal
working
volt

Contacts

Max full
operating
volts

Minimum
release
volts

PIN code

iQNNA1-12F-4B-50

50

2x(6F 2B)

40V

7.5V

CEFHJ

iQNNA1-8F-8B-50

50

2x(4F 4B)

40V

7.5V

CEGHJ

iQNNA1-12F-4B-24

24

2x(6F 2B)

19.2V

3.6V

CDEHX

iQNNA1-8F-8B-24

24

2x(4F 4B)

19.2V

3.6V

ACDHJ

20

Please note: Selectrail reserves the right to alter information contained within this document without notice
Selectrail (Australia) Pty Ltd

CONTACT LAYOUT :
Note : Layouts shown are when viewed from the rear of the
relay.

iQS2 & iQS3

DC neutral
Sensitive type
For long supply lines
Patent applied for
SIL4 compliant*

* Front contacts only in accordance with railway signalling rules.

Product code

Nominal
working
volt

Contacts

Max full
operating
volts

Minimum
release
volts

PIN code

iQS2-2F-2B-50

50

2F 2B

36V

7.5V

CEFGH

iQS2-6F-6B-12

12

6F 6B

9.6V

1.8V

BCGHX

iQS3-6F-6B-12

12

6F 6B

9V

3.5V

CHJKX

iQS3-4F-4B-12

12

4F 4B

9V

3.5V

DEFGX

iQS3-2F-2B-12

12

2F 2B

9V

3.5V

DEFHX

iQS3-4F-4B-12

12

4F 4B

9V

3.5V

CDEKX

iQS3-6F-2B-24

24

6F 6B

19.2V

3.6V

BDEKX

Please note: Selectrail reserves the right to alter information contained within this document without notice
Selectrail (Australia) Pty Ltd

21

iQSA3

CONTACT LAYOUT :
Note : Layouts shown are when viewed from the rear of the
relay.

AC immune
Sensitive type
Patent applied for
SIL4 compliant*

* Front contacts only in accordance with railway signalling rules.

Product code

iQSA3-4F-4B-24

22

Nominal
working
volt

Contacts

Max full
operating
volts

Minimum
release
volts

PIN code

24

4F 4B

19.2V

3.6V

CDEKY

Please note: Selectrail reserves the right to alter information contained within this document without notice
Selectrail (Australia) Pty Ltd

iQSELECT1
iQSELECT1 is single biased, AC immune dual
microprocessor controlled slow release solid state relay for
safety critical applications contained within a standard Q
style enclosure which directly drives an external slave relay.

Patent applied for

The iQSELECT1 provides a delay between the opening of a


control contact and the release of a normally energised slave
relay.
Time delays can be easily and accurately set by installing
straps on the rear of the plugboard to provide timing delays
between 0.050 seconds an 300.0 seconds. iQSELECT1
relays can be shipped with the desired delay value upon
request.
Two microcontrollers, operating as doer and checker, control
the contact (switch) state providing voltage to the slave relay
and delay timing when monitoring and displaying the control
contact and slave relay drive status.
The slave drive output is controlled by 2 pairs of solid state
MOSFET switches with each member of the individual pair
connected in series. The solid state switches are, in turn,
each controlled by a separate microcontroller through LED/
photodetector arrays. This arrangement, coupled with
the microcontrollers error checking software and voltage
monitoring hardware provide the relay with the ability to force
the output to a safe, default state in the event of a detected
failure.
Upon expiry of the time delay, both the positive and negative
feeds to the coil of the slave relay are opened.
iQSELECT1 is provided with two 4 digit displays. The upper
display indicates the programmed delay time and the lower
display indicates in real-time the remaining delay value until
time-out. The state of slave relay is indicated by the LED D56
and the state of the control contact by LED D34.
The slave relay (connected to R3/R4) is driven by
two MOSFET switches connected in series with each
MOSFET controlled by a separate microcontroller. Both
microcontrollers must be in agreement for the slave relay
to energise or remain energised. When the Control Contact
(D3/D4) is opened, both microcontrollers commence
their timing. When the microcontrollers complete their
timing operation, their respective MOSFET are disabled
resulting in the de-energisation of the slave relay. In the
event of disagreement between microcontrollers, the first
microcontroller to complete its timing operation will cause
the de-energistion of the slave relay and error condition will
be indicated on the LED display.

Please note: Selectrail reserves the right to alter information contained within this document without notice
Selectrail (Australia) Pty Ltd

23

Two stable clocks ensure that


delay timing remains unaffected by
environmental condition such as
temperature and provides highly
repeatable and accurate time delays.

CONFIGURATION

Plugboard straps A1, A2, A3, and A7


provide the coarse time delay values
(0-3 Sec, 3-11 Sec, 11-31 Sec, 31100 Sec or 101-300 Sec).
Fine adjustment of the time delay
is achieved via 3 programming
pushbuttons accessible by removal of
the relay cover.
The iQSELECT1 is provided as a
nominal 12V relay and derives the
slave voltage from an onboard boost
regulator circuit to provide 12V, 24V or
50V depending on the position of the
plugboard straps eliminating the need
for separate supplies.

Coarse Time Delay Selection

SPECIFICATION:
Nominal Supply Voltage: 12 VDC
Control: D3/D4
Reset: D5/D6
Power: R1/R2
Output: R3/R4
Output current: 3.4A@200C
Timing: programmable from 0.050
to 300.0 seconds
Timing Accuracy: 50mSec
Pickup Voltages: 8.0V
Drop Away Voltages: 7.0V
Weight: 400gm

Product code
iQSELECT1-1F-0B-12

24

Slave Voltage Selection

Min (S)

Max (S)

Strap

Slave Voltage

Strap

0.050

10.95

None

12V

D2-D1

11.00

30.95

A1-A7

24V

D2-D7

31.00

100.9

A1-A2-A7

50V

D2-D8

101.0

300.0

A1-A2-A3-A7

Vnom

Pick

Drop

Contacts

PIN code

12

8.0V

7.0V

BCEGX

Please note: Selectrail reserves the right to alter information contained within this document without notice
Selectrail (Australia) Pty Ltd

CONTACT LAYOUT :
Note : Layouts shown are when viewed from the rear of the
relay.

iQSELECT2

Please note: Selectrail reserves the right to alter information contained within this document without notice
Selectrail (Australia) Pty Ltd

Time delay relay


Patent applied for

25

For increased resolution, the delay


can be further adjusted to four digit
precision using the pushbuttons
accessible beneath the cover.
For example, a 2.5 second delay ca
be adjusted between 0.050 seconds
(the minimum) and 7.500 seconds
in increments of 0.001 second. A 50
second delay can be adjusted between
42.00 and 55.00 seconds in increments
of 0.01 seconds and a 102 second
delay between 97.0 seconds and 108.0
seconds in 0.1 second increments.
Note that the 325 second delay can be
extended to 9,999 seconds (2 hours,
46 minutes, 39 seconds).
The iQSELECT2 is available in two
contact configuration in each of the 3
common nominal voltages to provide
backwards compatibility with legacy
slow pick timer relays.

26

To set the delay timing value, straps are installed in various


configurations at the plugboard between the A and D stacks as
shown in Table 1 below, providing for 56 timer ranges.

Table 1
Time (s)

Coarse Strap

Fine Strap

2.5

A1-B7

B7-B8

7.5

A1-B7

13.5

Time (s)

Coarse Strap

Fine Strap

167

A1-A4

B7-B8

B7-A8

173

A1-A4

B7-A8

A1-B7

A8-B8

178

A1-A4

A8-B8

18.5

A1-B7

184

A1-A4

26

A1-A7

B7-B8

191

A1-B3

B7-B8

31

A1-A7

B7-A8

196

A1-B3

B7-A8

37

A1-A7

A8-B8

202

A1-B3

A8-B8

42

A1-A7

207

A1-B3

50

A1-B6

B7-B8

214

A1-A3

B7-B8

55

A1-B6

B7-A8

220

A1-A3

B7-A8

61

A1-B6

A8-B8

226

A1-A3

A8-B8

66

A1-B6

231

A1-A3

73

A1-A6

B7-B8

238

A1-B2

B7-B8

78

A1-A6

B7-A8

243

A1-B2

B7-A8

84

A1-A6

A8-B8

249

A1-B2

A8-B8

89

A1-A6

254

A1-B2

97

A1-B5

B7-B8

262

A1-A2

B7-B8

102

A1-B5

B7-A8

267

A1-A2

B7-A8

108

A1-B5

A8-B8

273

A1-A2

A8-B8

113

A1-B5

278

A1-A2

120

A1-A5

B7-B8

285

A1-B1

B7-B8

125

A1-A5

B7-A8

290

A1-B1

B7-A8

131

A1-A5

A8-B8

296

A1-B1

A8-B8

136

A1-A5

301

A1-B1

144

A1-B4

B7-B8

309

B7-B8

149

A1-B4

B7-A8

314

B7-A8

155

A1-B4

A8-B8

320

A8-B8

160

A1-B4

325

Please note: Selectrail reserves the right to alter information contained within this document without notice
Selectrail (Australia) Pty Ltd

iQSELECT2 is a biased, microprocessor controlled


slow operate relay contained within a standard Q
style enclosure and suitable for use in safety critical
applications.
When the control voltage applied across R1(+) and R2(-)
achieves the preset activation voltage level, the relay
initiates a timer loaded with a preselected value. When
the timer expires, the normally closed switches (back
contacts) are opened and, a few milliseconds later, the
normally open switches (front contact) are closed.
Conversely, when the applied control voltage drops to
the preset de-activation voltage level, the normally open
switches are opened and, a few milliseconds later, the
normally closed switches are closed regardless of the
state of the timer.
Stick contacts are provided at plugboard connections C5/
C6 to bypass time delay feature when bridged, resulting
in the immediate opening of all normally closed switches
and (milliseconds later) the closing of all normally open
switches.
The timer itself is 100% digital, based on a highly stable
4 MHz crystal and delay values are easily and accurately
set by installing straps on the rear of the plugboard
in the same arrangements as used with analogue
electromagnetic slow pick relays.
Two microcontrollers, operating as doer and checker,
control the switch states and delay timing while
continually monitoring and displaying the state of the
various switches.
10 bit analogue to digital converters in the
microcontrollers provide for precise measurements of the
applied control voltages levels, dramatically reducing the
voltage range where the state of the relay is undefined
and improving the accuracy of the timing under varying
environmental conditions.
Each switch circuit is comprised of two solid state
MOSFET devices connected in series with each device
under the control of a separate microcontroller. This
arrangement, coupled with the microcontrollers error
checking software and voltage monitoring hardware
provide the relay with the abitity to force the outputs to a
safe, default state in the event of a detected failure.

Please note: Selectrail reserves the right to alter information contained within this document without notice
Selectrail (Australia) Pty Ltd

27

Figure 1 below illustrates how the iQSELECT2 may be


utilitised to delay the activation of a second relay for 18.5
seconds following the deactivation of a first relay.

SPECIFICATION:
Nominal Supply Voltage: 12VDC,
24VDC, 50VDC
Contact Configurations: 5F 2B
1S, 4F 3B 1S
Output current: 3.4A/contact
@200C
Timing: programmable from 0.500
to 9,999 seconds
Timing Accuracy: 10mSec
Activation (Pickup) Voltages: 8.0V
(12V), 15.0V (24V), 29.0V (50V)
De-activation (Drop Away)
Voltages: 7.0V (12V), 14.0V (24V),
28.0V (50V)
Weight: 500gm

Figure 1

Nominal
working
volt

Contacts

Max full
operating
volts

Minimum
release
volts

PIN code

iQSELECT2-5F-2B-50

50

5F 2B

40V

7.5V

BDFHX

iQSELECT2-4F-3B-50

50

4F 3B

40V

7.5V

BEGHX

iQSELECT2-5F-2B-24

24

5F 2B

19.2V

3.6V

BDFJX

iQSELECT2-4F-3B-24

24

4F 3B

19.2V

3.6V

BEFKX

iQSELECT2-5F-2B-12

12

5F 2B

10V

1.8V

BDGHX

iQSELECT2-4F-3B-12

12

4F 3B

10V

1.8V

BEFJX

Product code

28

Please note: Selectrail reserves the right to alter information contained within this document without notice
Selectrail (Australia) Pty Ltd

CONTACT LAYOUT :
Note : Layouts shown are when viewed from the rear of the
relay.

iQSELECT3

DC biased
AC immune
Solid state twin timer relay
Patent applied for

Vnom(V)

Contacts

Pick (V)

Drop (V)

PIN code

iQSELECT3-6F-0B-50

50

2x(3F 0B)

28.3V

28.0V

ACGJX

iQSELECT3-4F-2B-50

50

2x(2F 1B)

28.3V

28.0V

ACGJW

iQSELECT3-6F-0B-24

24

2x(3F 0B)

14.3V

14.0V

ACHJX

iQSELECT3-4F-2B-24

24

2x(2F 1B)

14.3V

14.0V

ACGJV

iQSELECT3-6F-0B-12

12

2x(3F 0B)

7.3V

7.0V

ABEFS

iQSELECT3-4F-2B-12

12

2x(2F 1B)

7.3V

7.0V

ABEFU

Product code

Please note: Selectrail reserves the right to alter information contained within this document without notice
Selectrail (Australia) Pty Ltd

29

iQSPA1

CONTACT LAYOUT :
Note : Layouts shown are when viewed from the rear of the
relay.

Slow to operate type


DC neutral
Typical use track circuit repeater
Patent applied for
SIL4 compliant*

* Front contacts only in accordance with railway signalling rules.

Product code

Nominal
working
volt

Contacts

Max full
operating
volts

Minimum
release
volts

PIN code

iQSPA1-8F-4B-50

50

8F 4B

40V

7.5V

ABDGJ

iQSPA1-8F-4B-24

24

8F 4B

19.2V

3.6V

ABDEJ

30

Please note: Selectrail reserves the right to alter information contained within this document without notice
Selectrail (Australia) Pty Ltd

CONTACT LAYOUT :
Note : Layouts shown are when viewed from the rear of the
relay.

iQSRA1

Slow release type


AC Immune
DC neutral
Patent applied for
SIL4 compliant*

* Front contacts only in accordance with railway signalling rules.

Product code

Nominal
working
volt

Contacts

Max full
operating
volts

Minimum
release
volts

PIN code

iQSRA1-8F-4B-50

50

8F 4B

40V

7.5V

ADEHJ

iQSRA1-8F-4B-24

24

8F 4B

19.2V

3.6V

ADEFJ

iQSRA1-8F-4B-12

12

8F 4B

9.6V

1.8V

ABFJM

Please note: Selectrail reserves the right to alter information contained within this document without notice
Selectrail (Australia) Pty Ltd

31

iQT1 & iQT2





CONTACT LAYOUT :
Note : Layouts shown are when viewed from the rear of the
relay.

DC neutral
Track relay
Patent applied for
SIL4 compliant*

* Front contacts only in accordance with railway signalling rules.

Product code

Nominal
working
volt

Contacts Operating current (mA)


Max.

Min.

Minimum %
release

PIN code

iQT1-2F-2B-0.5

0.5

2F 2B

117

103

68

ACFGK

iQT2-2F-0B-0.5

0.5

2F 0B

117

103

68

ACFGK

iQT2-2F-2B-1.4

1.4

2F 2B

117

109

68

DEFJX

iQT2-2F-1B-0.5

0.5

2F 1B

117

109

68

EHJKX

iQT2-8F-8B-24

24

8F 8B

74

45mA

BDEGX

iQT2-2F-2B-24

24

2F 2B

74

45mA

BDEGX

32

Please note: Selectrail reserves the right to alter information contained within this document without notice
Selectrail (Australia) Pty Ltd

CONTACT LAYOUT :
Note : Layouts shown are when viewed from the rear of the
relay.

iQTA2

AC Immune
DC neutral
Track relay
Patent applied for
SIL4 compliant*

* Front contacts only in accordance with railway signalling rules.

Product code

Nominal
working
volt

Contacts Operating current (mA)


Max.

Min.

Minimum %
release

PIN code

iQTA2-2F-0B-1.4

1.4

2F 0B

140

120

68

ADEJK

iQTA2-2F-0B-2

2.0

2F 0B

92

81

68

ACGJK

iQTA2-2F-1B-1.4

1.4

2F 1B

140

120

68

FGHKX

iQTA2-2F-2B-1.4

1.4

2F 2B

140

120

68

ADEJK

Please note: Selectrail reserves the right to alter information contained within this document without notice
Selectrail (Australia) Pty Ltd

33

iQUCX1 &
iQUCX2

CONTACT LAYOUT :
Note : Layouts shown are when viewed from the rear of the
relay.

AC current operated
Line relay
For 110V signalling
Lamp proving of position lamp
junction indicators (5 lamps at
110V/25W) use iQUCX1
Operate with 4 lamps burning
and release with 2 lamps burning
Lamp proving of position lamp
junction indicators (5 lamps at
30V/25W) use iQUCX2
Patent applied for
SIL4 compliant*

* Front contacts only in accordance with railway signalling rules.

Product code

Nominal
working
volt

Contacts

Max full
operating
current (mA)

Minimum
release
current (mA)

PIN code

iQUCX1-2F-2B-1.4

1.4

2F 2B

700

520

AFGHJ

iQUCX2-2F-2B-0.73

0.73

2F 2B

350

250

ACEFS

34

Please note: Selectrail reserves the right to alter information contained within this document without notice
Selectrail (Australia) Pty Ltd

PLUGBOARD

LAYOUT :

14

J
S

N A B PL
Q C D
E FG H
J
K
S
T

56

117

28

Supplied with PIN codes


pre-drilled or undrilled

117

4
126

126
A

28
4

14

N
Q

C
G

D
H
K

56

Product code

Description

Q-PLUGBOARD
Q-(pin code)-B

Q style plugboard undrilled.


Q style plugboard drilled to customers requirements.
e.g. ABFGK interlocking pin code required.
Pre drilled plugboard part number example = Q-ABFGK-B

Please note: Selectrail reserves the right to alter information contained within this document without notice
Selectrail (Australia) Pty Ltd

35

LAYOUT :

128
35

R6 (TYP)

103

301 spring-tempered Stainless


Steel

190

98

40
20

15

RETAINING
CLIP

60

60

R3

R3

Product code
PI5369-18

36

86

2.5

Description
Retaining Clip
Please note: Selectrail reserves the right to alter information contained within this document without notice
Selectrail (Australia) Pty Ltd

HEAD OFFICE
13 TREVI CRESCENT,
TULLAMARINE, VIC 3043
AUSTRALIA
TEL
+61-3-9335 0600
FAX
+61-3-9335 0601
EMAIL INFO@SELECTRAIL.COM
WEB WWW.SELECTRAIL.COM

INDONESIA

REP.OFFICE

RUKO BIDEX A-25, JL. PAHLAWAN SERIBU,


BSD CITY, TANGERANG - INDONESIA
TEL
+62-21 531 53991
FAX +62-21 531 53982
EMAIL INDONESIA@SELECTRIX.COM

SURABAYA OFFICE

RUKO KLAMPIS MEGAH BLOK G-10,


SURABAYA 60117
TEL
+62-31 595 0640
FAX +62-31 595 0640

FACTORY

KAWASAN INDUSTRI DE PRIMA TERRA


JL. SAPAN BLOK A1 NO. 6-7
BOJONGSOANG, BANDUNG 40288

WWW. SELECTRAIL.COM

You might also like