1.INTRODUCTION
1-1
Communications .............................................................................................................................. 1 - 1
For Further Assistance ............................................................................................................................1 - 2
2.COMMUNICATION PORTS
2-1
RS485 Port........................................................................................................................................... 2 - 1
RS485 ..............................................................................................................................................................2 - 1
WiFi ......................................................................................................................................................... 2 - 2
WiFi Quick Start Procedure...................................................................................................................2 - 4
USB.......................................................................................................................................................... 2 - 5
Using the Quick Connect Feature via the USB Port...................................................................2 - 5
3.TIME PROTOCOLS
3-1
Real-time Clock ................................................................................................................................. 3 - 1
IEEE 1588 Precision Time Protocol (PTP) .........................................................................................3 - 1
PTP Status......................................................................................................................................................3 - 1
PTP Configuration ......................................................................................................................................3 - 3
Clock ................................................................................................................................................................3 - 4
IRIG-B...............................................................................................................................................................3 - 5
4.DNP PROTOCOL
4-1
DNP communication ...................................................................................................................... 4 - 3
DNP device profile ........................................................................................................................... 4 - 7
DNP implementation ....................................................................................................................4 - 10
5-1
6.IEC 60870-5-104
6-1
Interoperability.................................................................................................................................. 6 - 2
7.IEC 60870-5-103
7-1
Cause of Transmission .................................................................................................................. 7 - 1
Communications Menus............................................................................................................... 7 - 2
Interoperability.................................................................................................................................. 7 - 4
Physical layer..............................................................................................................................................7 - 4
Electrical interface.....................................................................................................................................7 - 4
Optical interface.........................................................................................................................................7 - 4
Transmission speed..................................................................................................................................7 - 4
TOC-1
8.IEC 61850
8-1
General ..................................................................................................................................................8 - 1
Functionality .......................................................................................................................................8 - 4
The IEC 61850 Configurator.........................................................................................................8 - 5
Online and Offline Setup........................................................................................................................ 8 - 5
IEC 61850 Configurator Details .......................................................................................................... 8 - 7
ICD/CID........................................................................................................................................................... 8 - 7
Settings.......................................................................................................................................................... 8 - 9
Reports.........................................................................................................................................................8 - 12
Goose Transmission ..............................................................................................................................8 - 17
Goose Reception .....................................................................................................................................8 - 22
9-1
10.MODBUS PROTOCOL
10 - 1
Modbus Protocol ............................................................................................................................ 10 - 2
Administrator Login and Commands via Modbus for 8 Series Relays ..........................10 - 7
11 - 1
A-1
B-1
Warranty ..............................................................................................................................................B - 1
Revision history .................................................................................................................................B - 1
Major Updates............................................................................................................................................ B - 1
TOC-2
GE
Grid Solutions
Introduction
The Multilin 8 Series relay protective relay platform includes four different relays, the 850,
845, 869, and 889. Information in this manual applies to all 8 Series relays unless otherwise
indicated.
The Multilin 850 relay is a microprocessor-based unit intended for the management and
primary protection of distribution feeders, as well as for the management and backup
protection of buses, transformers, and transmission lines. The 850 relay is particularly
suited to overhead feeders, where automatic reclosing is normally applied.
The Multilin 869 relay is a microprocessor-based unit intended for the management and
primary protection of medium and large sized motors. Base relay models provide thermal
overload and overcurrent protection plus a number of current and voltage based backup
functions.
The Multilin 845relay is a microprocessor-based unit intended for the management and
primary protection of the medium to large size medium voltage (MV) and high voltage (HV)
power transformers. Both 2-winding and 3-winding transformers are supported. The 845
relay provides a number of primary and backup current and voltage based protection
functions. This system allows for control of the circuit breakers at each winding plus a
number of monitoring and control functions are also provided.
The Multilin 889 relay is a microprocessor-based unit intended for the primary protection
of small, medium and large sized generators. Base relay models provide standard
generator protection functions plus a number of current and voltage based backup
functions.
Communications
The 8 Series relays have a two-stage communications capability. The base CPU supports
Modbus protocol through the Ethernet, USB, serial and WiFi port. In addition, the base CPU
also supports IEC 103, DNP serial, and TFTP protocol. Once the communications module
option is added to the base, the base Ethernet port becomes disabled but the two Ethernet
ports on the communications module have enhanced communications capabilities such
as IEC61850, IEC62439 parallel redundancy protocol and IEEE 1588 Precision Time
Protocol. The communications CPU also supports Modbus TCP, IEC 104, DNP TCP, TFTP,
SFTP, and SNTP protocol.
1-1
COMMUNICATIONS
CHAPTER 1: INTRODUCTION
1-2
GE
Grid Solutions
Communication Ports
8 Series protective relays have four communications ports: RS485, WiFi, USB, and Ethernet.
RS485 Port
SERIAL
RS485 port: ............................................................Isolated
Baud rates:.............................................................Supports 9600, 19200, 38400, 57600, and 115200 kbps
Response time:.....................................................10 ms typical
Parity: .......................................................................None, Odd, Even
Protocol: ..................................................................Modbus RTU, DNP 3.0, IEC 60870-5-103
Maximum distance: ...........................................1200 m (4000 feet)
Isolation:..................................................................2 kV
RS485
On the rear card 8 Series relays are equipped with one RS485 serial communication port
and one 10/100 Mbps Ethernet port. The RS485 port has settings for baud rate and parity.
It is important that these parameters agree with the settings used on the computer or
other equipment connected to this port. A maximum of 32 relays can be daisy-chained
and connected to a DCS, PLC or a PC using the RS485 port.
Path: Setpoints > Device > Communications > RS485
BAUD RATE
Range: 9600, 19200, 38400, 57600, 115200
Default: 115200
PARITY
Range: None, Odd, Even
Default: None
PORT PROTOCOL
Range: Modbus, DNP 3.0, IEC 60870-5-103
Default: Modbus
2-1
WIFI
WiFi
WiFi refers to Wireless Local Area Networks (WLANs) that are based on the 802.11 set of
standards. WLANs are essentially providing Local Area Network (LAN) type of connectivity
but without the need of cables, which makes them more convenient for use in limited
spaces. WiFi works on top of the TCP/IP stack, the same as Ethernet. The signal strength
and its range is determined by the wireless devices antenna technology and standard, the
best being IEEE 802.11n.
WiFi defines two modes of operation, namely ad-hoc, used for small deployments, and
infrastructure mode, which supports more robust types of security and better capabilities
for centralized management. The infrastructure mode requires an access point (AP).
Devices operating in this mode pass all data through the AP.
The WiFi module integrated on the 8-Series products conforms to IEEE 802.11b/g/n
standards. The 8-Series devices operate in infrastructure mode. Security is optional, but
enabled by default and it is advisable that it is left on, as wireless traffic is very susceptible
to cyber-attacks.
The security technology used is WPA2 (Wireless Protected Access version 2), based on the
IEEE 802.11i standard for data encryption. WPA2 is a second version of WPA technology,
designed to solve known security limitations found in one of the encryption algorithms
used by WPA, namely TKIP (Temporal Key Integrity Protocol). WPA2 uses CCMP (Counter
Mode with Cipher Block Chaining Message Authentication Code Protocol), which provides
an enhanced data cryptographic encapsulation mechanism based on AES (Advanced
Encryption Standard). CCMP makes WPA2 much stronger and secure than its
predecessors, WPA and WEP.
Several forms of WPA2 security keys exist. The 8-Series supports WPA2 PSK (Pre-Shared
Key), which utilizes 64 hexadecimal digits. The key may actually be entered as a string of
64 hexadecimal digits or as a passphrase of 8 to 32 printable ASCII characters. For user
convenience, the settings accept the key in the form of a passphrase. Internally the ASCII
passphrase is used for deriving a 256-bit key.
WiFi Settings
The following are the WiFi network settings for the 8-Series product. Only an Administrator
has the rights to change them.
Path: Setpoints > Device > Communications > WiFi
..\Communications\WiFi
Item Name
WiFi Enable
WiFi IP Address
WiFi Subnet Mask
WiFi GWY IP Address
WiFi Security
WiFi SSID
WiFi WPA2 passphrase
Value
Unit
Enabled
192.168. 0. 2
255.255.255. 0
192.168. 0. 1
WPA2-PSK
GEMULTILIN
Ge1wx9s3123!4
WiFi
WiFi Enable
2-2
WIFI
This setting switches WiFi functionality on/off. By default WiFi is enabled in the basic
offering, but it is disabled in software options that offer CyberSentry.
WiFi IP Address / Subnet Mask
The default IP address is 192.168.0.x, where x is calculated as:
X = (modulo 242 of the last 3 digits of the serial number) + 12
This is to ensure uniqueness of the default IP address for all 8 Series devices present on one
wireless network and it creates a usable address space from 192.168.0.12 to 192.168.0.253
for 8 Series devices.
NOTE:
NOTE
From the remaining range of unicast addresses 192.168.0.1 to 192.168.0.11, at least two
are going to be used for the AP and a laptop installed with the EnerVista software, which
will be used to configure the 8 Series devices. The AP should be configured with the
address 192.168.0.1 and mask 255.255.255.0 and have DHCP enabled with a DHCP range
from 192.168.0.2 to 192.168.0.11. This allows laptops, iPads and any other devices
(Android, iPhone) to connect to the local network without the need to statically configure
their own IP address and mask.
WiFi GWY IP Address
The setting specifies the address of the access point AP which the 8 Series device uses for
communicating over WiFi.
WiFi Security
The setting enables WiFi security. If set to None, there is no security and all traffic is open.
By default WiFi Security is set to WPA2-PSK.
WiFi SSID
The SSID is the public name of a wireless network. All of the wireless devices on a WLAN
must use the same SSID in order to communicate with each other. The default for the SSID
is provided by the vendor with the shipment of any new 8-Series device. It is
recommended that the customer modifies this name as needed after initial startup, to
ensure unique SSIDs if several WLANs are configured.
NOTE:
NOTE
SSID broadcast should be disabled on AP. This provides some extra protection by requiring
a user to know an SSID before the user can connect to the device and making it harder for
casual outsiders looking for wireless networks to find the device and attempt to connect.
WiFi WPA2 Passphrase
The WPA2 Passphrase is used for generating the encryption key. The same passphrase
must be set on AP and on all devices communicating on the same WLAN. The 8-Series
device supports a string of up to 14 printable ASCII characters. Internally a 256-bit key is
calculated by applying the PBKDF2 key derivation function to this passphrase, using the
SSID as the salt and 4096 iterations of HMAC-SHA1.
The 8-Series devices are configured with a default passphrase, which is provided by the
vendor with the shipment of any new 8-Series device.
When choosing a new passphrase, the password complexity rules of CyberSentry must be
used (see CyberSentry details in the relay Instruction manual).
This field is visible only if the security is set to WPA2-PSK.
NOTE:
NOTE
Ideally the passphrase should be set through EnerVista and not directly from the Keypad,
where there are limitations in terms of space and types of characters supported. However,
for convenience, the key setting is available from the Keypad as well.
WiFi Status
A WiFi symbol is displayed in the caption area of the 8-Series product front panel. The
following table lists all possibilities for this icon:
2-3
WIFI
WiFi State
Disabled
Disconnected
Grey
Connecting
Yellow
Connected
Green
WiFi Events
Event
Description
WiFi Connected
WiFi Disconnected
If the relay is in service mode and the settings are default a minor error is triggered.
NOTE:
NOTE
PC with WiFi
Access Point
2-4
1.
2.
IP address:
192.168.0.1
Subnet Mask:
255.255.255.0
SSID:
Broadcast
disabled
Security type:
WPA2-PSK (WPA2-Personal)
Encryption:
AES
Passphrase:
DHCP enabled
3.
If the 8-Series relay(s) are in range, they automatically connect to the configured
Access Point.
4.
Start EnerVista on a PC and use the Discover function, all relays within range appear
and are populated in Enervista for initial configuration and commissioning.
5.
Once the relay is configured, change the 8-Series relay default WiFi SSID and
Passphrase settings before the relay goes into service.
USB
USB
The USB parameters are as follows:
IP Address: 172.16.0.2
IP Mask: 255.255.255.0
IP Gateway: 172.16.0.1
FASTPATH:
FASTPATH:
Whenever the device is rebooted, the USB cable needs to be unplugged and plugged in
again for proper communication to be established over USB.
Connecting multiple 8 Series relays over USB to a single PC is not possible because in the
case of USB, the IP address of the device 172.16.0.2 is constant.
Verify that the latest version of the EnerVista 8 Series Setup software is installed
(available from the GE EnerVista CD or online from http://www.gegridsolutions.com/
multilin). See the software installation section in the relay Instruction Manual for
installation details.
2.
3.
2-5
ETHERNET PORTS
4.
Click the Quick Connect button to open the Quick Connect dialog box.
5.
6.
The EnerVista 8 Series Setup software creates a site named Quick Connect with a
corresponding device also named Quick Connect and displays them on the upperleft corner of the screen. Expand the sections to view data directly from the device.
Ethernet Ports
The following communication offerings are available.
Base Offering
Modes: 10/100 Mbps
One Port: RJ45
Protocol: Modbus TCP, TFTP, DNP3.0
Communications Card Option
Modes: 100 MB
Two Ports: ST (with this option both enabled ports are on the communications card; the
Ethernet port located on the base CPU is disabled)
Protocols: Modbus TCP, DNP 3.0 TCP, IEC 60870-5-104, IEC 61850 MMS Server/GOOSE,
IEEE 1588, SNTP, IEC 62439-3 clause 4 (PRP), TFTP, SFTP
NOTE
The softkeys and Down/Up key can be used to enter an IP address. When entering an IP
address you must press the Back key first to switch between softkey mode and the
Down/Up key mode.
NETWORK 1, 4, 5, PRT1(4,5) IP ADDRESS
Range: Standard IPV4 Address format
Default: 169.254.3.3 (Port 1)
Default: 127.0.0.1 (Port 4, 5)
The setting sets the ports IPV4 address in standard IPV4 format.
2-6
ETHERNET PORTS
The setting is valid on port 1 if the optional communications card is not present.
NOTE:
NOTE
NOTE:
NOTE
Notes:
Changes to the Ethernet communications settings take effect only after rebooting the
relay.
All Ethernet ports have flex operands associated with them. A failure of one of the
Ethernet ports will trigger an event, a target message and the corresponding operand
set.
PRT4 OPERATION
Range: Independent, LLA, PRP
Default: Independent
This setting determines the mode of operation for ports 4 and 5: INDEPENDENT, LLA or
PRP.
INDEPENDENT operation: ports 4 and 5 operate independently with their own MAC and
IP address.
LLA operation: the operation of ports 4 and 5 are as follows:
Ports 4 and 5 use port 4s MAC and IP address settings while port 5 is in standby mode in
that it does not actively communicate on the Ethernet network but monitors its link. If
Port 4 is active and the link loss problem is detected, communications is switched to Port
5 immediately. Port 5 is, in effect, acting as a redundant or backup link to the network
for port 4.
LLA (Link Loss Alert) is a proprietary feature supported by the 8 Series relay fiber optic
ports. When enabled on an 8 Series fiber optic port, this feature is able to detect a failure
of the fiber link. If port 4s OPERATION is set to LLA, the detection of a link failure by this
feature triggers the transfer of communications from port 4 to port 5. If LLA is enabled
on a port with a non-fiber SFP, the target message LLA not supported by Prt (4 or 5) is
displayed on the keypad and an event is logged.
PRP (Parallel Redundancy Protocol): ports 4 and 5 use the same MAC address and
combine information at the link layer. It is intended to only be used if the two ports are
connected to separate parallel LANs. In this mode of operation both ports cannot be
connected to the same LAN. The receiving devices (8 Series relay ) process the first
frame received and discard the duplicate through a link redundancy entity (LRE) or
similar service that operates below layer 2. Aside from LRE, PRP uses conventional
Ethernet hardware but both ports must know they are in PRP. Ports of PRP devices
2-7
ETHERNET PORTS
operating with the same Internet Protocol (IP) addresses for traffic that uses IP
Management protocols such as Address Resolution Protocol (ARP) must operate
correctly.
Duplicate Discard mode (only mode supported by the 8 Series). This is the normal
setting for PRP operation and once set it allows the sender LRE to append a six-octet
field that contains a sequence number, the Redundancy Control Trailer (RCT) to both
frames it sends. The receiver LRE uses the sequence number of the RCT and the source
MAC address to detect duplicates. It forwards only the first frame of a pair to its upper
layers.
Routing
When the configuration card is present, a default route and a maximum number of 6 static
routes can be configured. The default route is used as the last choice, if no other route
towards a given destination is found.
Figure 2-2: Device Display for Routing Hierarchy
Setpoints
Device
Communications
Ethernet
Default Route
Routing
Gateway Address
Rt1 Destination
Static RT1
Rt1 Net Mask
Rt1 Gateway
Rt6 Destination
Static RT6
Level 1
Level 2
Level 3
Level 4
Level 5
Level 6
SETTINGS
DEFAULT ROUTE:
Gateway Address
Range: Standard IPV4 unicast address format (0.0.0.1 to 223.255.255.254)
Default: 127.0.0.1
This setting sets the gateway of the default route to be used by IP traffic sent from the
relay, if no other route towards a given IP destination is found.
This setting is available only if the communications card is present.
STATIC ROUTE 1 to 6:
2-8
ETHERNET PORTS
Defaults:
Rule #1.
By default, the value of the destination field is 127.0.0.1 for all static routes (1 to 6). This
is equivalent to saying that the static routes are not configured. When the destination
address is 127.0.0.1, the mask and gateway must also be kept as default values.Rule #2.
By default, the value of the default route gateway address is 127.0.0.1. This means the
default route is not configured.
Adding a route:
Rule #3.
Use any of the static network route entries numbered 1 to 6 to configure a static
network route. Once a route destination is configured for any of the entries 1 to 6, that
entry becomes a static route and it must meet all the rules listed in the following section
under Important Notes.
Rule #4.
To configure the default route, enter a default gateway address. A default gateway
address configured must be validated against Rule #5, the next rule.
Deleting a route:
Rule #5.
Routes are deleted by replacing the route destination with the default address
(127.0.0.1). When deleting a route, the mask and gateway must also be put back to their
default values.
Rule #6.
The default route is deleted by replacing the default gateway with the default value
127.0.0.1.
Important Notes:
1.
2.
The route mask has IPv4 mask format. In binary this is a set of contiguous bits of 1
from left to right, followed by one or more contiguous bits of 0.
3.
4.
Item #3, above, can be verified by checking that RtDestination & RtMask ==
RtDestination
5.
6.
7.
8.
The route gateway must be on a connected network. This rule applies to the gateway
address of the default route as well.
9.
TARGETS
WRONG ROUTE CONFIG
2-9
ETHERNET PORTS
Description: A route with mismatched destination and mask has been configured.
Message: Wrong route configuration.
What to do: Rectify the IP address and mask of the mis-configured route.
TOPOLOGY EXAMPLE
Figure 2-3: Topology Example
In the above figure: Topology Example, the 8 Series device is connected through the two
Ethernet ports available on the communications card.
Port 4 (IP address 10.1.1.2) connects to LAN 10.1.1.0/24 and to the Internet through
Router1. Router 1 has an interface on 10.1.1.0/24 and the IP address of this interface is
10.1.1.1.
Port 5 (IP address 10.1.2.2) connects to LAN 10.1.2.0/24 and to EnerVista setup
program through Router 2. Router 2 has an interface on 10.1.2.0/24 and the IP
address of this interface is 10.1.2.1.
Configuration
Network addresses:
PRT54IP ADDRESS = 10.1.1.2PRT4 SUBNET IP MASK = 255.255.255.0PRT5 IP ADDRESS =
10.1.2.2PRT5 SUBNET IP MASK = 255.255.255.0
Routing Settings:
IPV4 DEFAULT ROUTE: GATEWAY ADDRESS = 10.1.1.1
STATIC NETWORK ROUTE 1:
Behavior: One static network route was added to the destination 10.1.3.0/24, where a
laptop running EnerVista is located. This static route uses a different gateway (10.1.2.1)
than the default route. This gateway is the address of Router 2, which is aware of
destination 10.1.3.0 and is able to route packets coming from the 8 Series device and
destined to EnerVista.
2-10
GE
Grid Solutions
Time Protocols
Real-time Clock
Path: Setpoints > Device > Real Time Clock
The 8 Series relay is capable of receiving a time reference from several time sources in
addition to its own internal clock for the purpose of time-stamping events, transient
recorders and other occurrences within the relay. The accuracy of the time stamp is based
on the time reference that is used. The 8 Series relay supports an internal clock, SNTP, IRIGB, and PTP IEEE 1588 as potential time references.
If two or more time sources are available, the time source with the higher priority shown in
Time Sources table is used where 1 is considered to be the highest priority. Please note
that the time source priority of PTP and IRIG-B can be swapped. If both PTP and IRIG-B are
available to the 8 Series relay, by default the 8 Series relay clock syncs to PTP over IRIG-B.
If PTP is not available the 8 Series relay CPU syncs the internal clock to IRIG-B.
Table 3-1: Time Sources
Time Source
Priority
PTP (IEEE1588)
1*
IRIG-B
2*
SNTP
Internal Clock
FASTPATH:
3-1
REAL-TIME CLOCK
Value
Unit
PTP
The RTC Sync Source actual value is the time synchronizing source the relay is using at
present. Possible sources are: Port 4 PTP Clock, Port 5 PTP Clock, IRIG-B, SNTP and None.
Grandmaster ID is the grandmaster Identity code being received from the present PTP
grandmaster, if any. When the relay is not using any PTP grandmaster, this actual value is
zero. The grandmaster Identity code is specified by PTP to be globally unique, so one can
always know which clock is grandmaster in a system with multiple grandmaster-capable
clocks.
RTC Accuracy is the estimated maximum time difference at present in the Real Time Clock
(RTC), considering the quality information imbedded in the received time signal, how long
the relay has had to lock to the time source, and in the case of time signal interruptions,
the length of the interruption. The value 999,999,999 indicates that the magnitude of the
estimated difference is one second or more, or that the difference cannot be estimated.
Port 4 (5) PTP State is the present state of the ports PTP clock. The PTP clock state is:
3-2
DISABLED
If the ports function setting is Disabled
NO SIGNAL
If enabled but no signal from an active master has been found and selected
CALIBRATING
If an active master has been selected but lock is not at present established
SYNCHRONIZED
If the port is synchronized
PTP Configuration
REAL-TIME CLOCK
Path: Setpoints > Device > Real Time Clock > Precision Time
..\Real Time Clock\Precision Time
Item Name
Value
Port 4 PTP Function
Disabled
Port 4 Path Delay Adder
0
Port4 Path Delay Asymmetry
0
Port 5 PTP Function
Disabled
Port 5 Path Delay Adder
0
Port5 Path Delay Asymmetry
0
Strict Power Profile
Enabled
PTP Domain Number
0
PTP VLAN Priority
4
PTP VLAN ID
0
PTP Priority
1
Unit
ns
ns
ns
ns
3-3
REAL-TIME CLOCK
Clock
Path: Setpoints > Device > Real Time Clock > Clock
3-4
REAL-TIME CLOCK
DATE
Format: Month/Day/Year
Range: Month: 1 to 12; Day: 1 to 31; Year: 2008 to 2094
Default: 01/01/2008
TIME
Range: 0 to 23: 0 to 59:0 to 59
Default: 00:00:00
LOCAL TIME OFFSET FROM UTC
Range: 24.0 to 24.0 hrs in steps of 0.5 hrs
Default: 0.0 hrs
REAL TIME CLOCK EVENTS
Range: Disabled, Enabled
Default: Enabled
IRIG-B
Range: Disabled, Enabled
Default: Disabled
DAYLIGHT SAVINGS TIME
Range: Disabled, Enabled
Default: Disabled
DST START MONTH
Range: January to December (all months)
Default: Not Set
DST START DAY
Range: SUN to SAT (all days of the week)
Default: Not Set
DST START WEEK
Range: 1st, 2nd, 3rd, 4th, Last
Default: Not Set
DST START HOUR
Range: 0 to 23
Default: 2
DST END MONTH
Range: January to December (all months)
Default: Not Set
DST END WEEK
Range: 1st, 2nd, 3rd, 4th, Last
Default: Not Set
DST END DAY
Range: SUN to SAT (all days of the week)
Default: Not Set
DST END HOUR
Range: 0 to 23
Default: 2
IRIG-B
IRIG-B is available in the basic offering of the product. A failure on IRIG-B triggers an event
and a target message.
3-5
REAL-TIME CLOCK
FASTPATH:
3-6
Note that IRIG-B is auto detect. The signal type is detected in hardware, so there are no
configurable options.
GE
Grid Solutions
DNP Protocol
4-1
DNP Channel 1 Port will take the DNP TCP/UDP Port 1 and DNP Client Address 1 to
allow/reject connections. The same relation is used by channel 2.
NOTE:
NOTE
DNP Address:
Range: 0 to 65519 in steps of 1
Default: 65519
The DNP address sets the DNP slave address. This number identifies the 8 Series relay on
a DNP communications link. Each DNP slave must be assigned a unique address.
DNP Unsol Resp Function:
Range: Enabled, Disabled
Default: Disabled
This setting will take effect for Ethernet communication only if the main card is present
or a comms card is available in the device. This setting enables/disables the unsolicited
response functionality. It is disabled for RS485 applications since there is no collision
avoidance mechanism.
DNP Unsol Resp Timeout:
Range: 0 to 60 s in steps of 1
Default: 5 s
Sets the time the 8 Series relay waits for a DNP master to confirm an unsolicited
response.
Unsol Resp Max Retries:
Range: 1 to 255 in steps of 1
Default: 10
Sets the number of times the 8 Series relay retransmits an unsolicited response without
receiving confirmation from the master; a value of 255 allows infinite re-tries.
DNP Unsol Resp Dest Addr:
Range: 1 to 65519 in steps of 1
Default: 1
Sets the DNP address to which all unsolicited responses are sent. The IP address to
which unsolicited responses are sent is determined by the 8 Series relay from the
current TCP connection or the most recent UDP message.
DNP Time Sync IIN Period:
Range: 1 to 10080 min. in steps of 1
Default: 1440 min
This setting determines how often the Need Time Internal Indication (IIN) bit is set by the
8 Series relay. Changing this time allows the DNP master to send time synchronization
commands more or less often, as required.
NOTE:
NOTE
If the requirement for synchronization is more than a couple of seconds, the user is
advised to consider synchronization via other means such as IRIGB or 1588. Given network
asymmetry, the consistency of the network latency, clock drift, and additional delays due
to routers located between the client and the 8 Series relay all contribute error.
DNP Message Fragment Size:
Range: 30 to 2048 in steps of 1
Default: 240
This setting determines the size, in bytes, at which message fragmentation occurs. Large
fragment sizes allow for more efficient throughput; smaller fragment sizes cause more
application layer confirmations to be necessary which can provide for more robust data
transfer over noisy communication channels.
4-2
DNP COMMUNICATION
DNP communication
The 8 Series relay supports Distributed Network Protocol (DNP) version 3.0. and the
8 Series relay operates as a DNP slave device. Two DNP masters can actively
communicate with the 8 Series relay at one time as the 8 Series relay maintains two sets
of DNP data change buffers and connection information. The following is a detailed
explanation of the 8 Series relay s DNP 3 implementation.
FASTPATH:
FASTPATH:
FASTPATH:
Both DNP and IEC104 protocol can work at the same time, but the user has to consider
that there is only one point map. So, the two protocols will use the same data mapping, i.e.
the same point index and same point source.
The 8 Series relay supports two DNP3.0 client connections simultaneously.
When configuring DNP do not use port 20057 since it is reserved for internal purposes by
the unit itself.
Figure 4-1: DNP Data Types
DATA TYPES
Binary input data: Binary input data is used to monitor two-state device operations
such as the position of a circuit breaker. The user can configure up to 96 Binary inputs.
All binary inputs are configured from Flexlogic operands.
Binary output data: Binary output data is used to control two-state devices such as
the tripping or circuit closing of a circuit breaker. The 8 Series relay can be configured
to support up to 16 Binary outputs. The slaves Binary outputs are automatically
4-3
DNP COMMUNICATION
mapped into the 8 Series relay virtual inputs starting at virtual input 1. Please note
that the number of Binary/ Control outputs is configurable. The user can configure a
subset that supports dual point control. This subset starts at address 0.
Analog input data: Analog input data is used to monitor analog signals such as
voltages, currents, and power. Up to 32 analog points can be mapped to the master.
Analog output data: Not supported in the 8 Series relay .
Time stamps
Count input data: Count input data could represent a cumulative quantity such as
kilowatt-hours of energy. Up to 16 counter points can be mapped to the master.
4-4
Object
8 Series relay
10
12
20
Counter Value
21
22
23
30
32
DNP COMMUNICATION
Data Format
The following setpoints are in the PATH: SETPOINTS > DEVICE > COMMUNICATIONS > DNP
PROTOCOL
If the additional communication module is not present, only RS485 is a possible option. The
Network options are hidden in this case and the DNP channel is assigned to the RS485 port
by default.
DNP ADDRESS
Range: 0 to 65519 in steps of 1
Default: 65519
Sets the DNP slave address. This number identifies this 8 Series relay on a DNP
communications link. Each DNP slave should be assigned a unique address.
DNP NETWORK CLIENT ADDRESS 1(2)
Range: Standard IP Address
Default: 0.0.0.0
The DNP Network Client Address settings can force the 8 Series relay to respond to a
maximum of two specific DNP masters.
DNP TCP/UDP PORT NUMBER 1 (2)
Range: 1 to 65535 in steps of 1
Default: 20000
The DNP NETWORK CLIENT ADDRESS 1(2) and DNP TCP/UDP PORT NUMBER 1(2) settings
are available only if the communications card is present. DNP Channel 1 Port takes the
Port Number 1 and Client Address 1 to allow or reject connections. The same relation
is used by channel 2.
DNP UNSOL RESPONSE FUNCTION
Range: Enabled, Disabled
Default: Disabled
Should be Disabled for RS485 applications since there is no collision avoidance
mechanism. Unsolicited response settings is hidden if the communication card is not
present, as DNP runs only on RS485 in this case.
4-5
DNP COMMUNICATION
If the requirement for time synchronization is more than a couple of seconds the user is
advised to consider time-sync via other means such as IRIG-B or 1588, given network
asymmetry, the consistency of the network latency, clock drift and additional delays due
to routers located between the client and the 8 Series relay , all of which contribute errors.
DNP MESSAGE FRAGMENT SIZE
Range: 30 to 2048 in steps of 1
Default: 240
This setting determines the size (maximum length of frame), in bytes, at which message
fragmentation occurs. Large fragment sizes allow for more efficient throughput; smaller
fragment sizes cause more application layer confirmations to be necessary which can
provide for more robust data transfer over noisy communication channels.
DNP OBJECT 1(2) DEFAULT VARIATION
Range: 1, 2
Default: 2
These settings allow the user to select the DNP default variation number for object types
1, 2, 20, 21, 22, 23, 30, and 32. The default variation refers to the variation response when
variation 0 is requested and/or in class 0, 1, 2, or 3 scans. The DNP binary outputs
typically map one-to-one to IED data points. That is, each DNP binary output controls a
single physical or virtual control point in an IED. In the 8 Series relay, DNP binary outputs
are mapped to virtual inputs.
DNP OBJECT 20(22) DEFAULT VARIATION
Range: 1, 2, 5, 6
Default: 1
For explanation, see above.
4-6
4-7
Transmitted: 292
Received: 292
Received: 2048
None
None
Fixed at 3
Configurable
Configurable
Requires Data Link Layer Confirmation:
Never
Always
Sometimes
Configurable
Requires Application Layer Confirmation:
Never
Always
When reporting Event Data
When sending multi-fragment responses
Sometimes
Configurable
Timeouts while waiting for:
Data Link Confirm:
None Fixed
Complete Appl. Fragment: None Fixed
Application Confirm:
None Fixed at 10 s
Complete Appl. Response: None Fixed at ___
Variable Configurable
Variable Configurable
Variable Configurable
Variable Configurable
Others:
Transmission Delay: No intentional delay
Need Time Interval: Configurable (default = 24 hrs.)
Select/Operate Arm Timeout: 10 s
Binary input change scanning period: 8 times per power system cycle
Analog input change scanning period: 500 ms
Counter change scanning period: 500 ms
Frozen counter event scanning period: 500 ms
4-8
4-9
DNP IMPLEMENTATION
DNP implementation
OBJECT
REQUEST
RESPONSE
OBJECT
NO.
VARIATION
NO.
DESCRIPTION
FUNCTION
CODES (DEC)
QUALIFIER CODES
(HEX)
Binary Input
(Variation 0 is used
to request default
variation)
1 (read)
22 (assign class)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited quantity)
17, 28 (index)
---
---
Binary Input
1 (read)
22 (assign class)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited quantity)
17, 28 (index)
129 (response)
00, 01 (start-stop)
17, 28 (index) (see
Note 2)
1 (read)
22 (assign class)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited quantity)
17, 28 (index)
129 (response)
00, 01 (start-stop)
17, 28 (index) (see
Note 2)
---
---
129 (response)
130 (unsol. resp.)
17, 28 (index)
129 (response)
130 (unsol. resp.)
17, 28 (index)
---
---
00, 01(start-stop)
06 (no range, or all)
07, 08 (limited quantity)
17, 28 (index)
---
---
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited quantity)
17, 28 (index)
129 (response)
00, 01 (start-stop)
17, 28 (index) (see
Note 2)
12
00, 01 (start-stop)
07, 08 (limited quantity)
17, 28 (index)
129 (response)
echo of request
20
Binary Counter
(Variation 0 is used
to request default
variation)
1 (read)
7 (freeze)
8 (freeze noack)
9 (freeze clear)
10 (frz. cl. noack)
22 (assign class)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited quantity)
17, 28 (index)
---
---
32-Bit Binary
Counter
1 (read)
7 (freeze)
8 (freeze noack)
9 (freeze clear)
10 (frz. cl. noack)
22 (assign class)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited quantity)
17, 28 (index)
129 (response)
00, 01 (start-stop)
17, 28 (index) (see
Note 2)
16-Bit Binary
Counter
1 (read)
7 (freeze)
8 (freeze noack)
9 (freeze clear)
10 (frz. cl. noack)
22 (assign class)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited quantity)
17, 28 (index)
129 (response)
00, 01 (start-stop)
17, 28 (index) (see
Note 2)
10
4-10
OBJECT
OBJECT
NO.
21
22
23
DNP IMPLEMENTATION
REQUEST
VARIATION
NO.
DESCRIPTION
FUNCTION
CODES (DEC)
RESPONSE
QUALIFIER CODES (HEX) FUNCTION CODES
(DEC)
QUALIFIER CODES
(HEX)
32-Bit Binary
1 (read)
Counter without Flag 7 (freeze)
8 (freeze noack)
9 (freeze clear)
10 (frz. cl. noack)
22 (assign class)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited quantity)
17, 28 (index)
129 (response)
00, 01 (start-stop)
17, 28 (index) (see
Note 2)
16-Bit Binary
1 (read)
Counter without Flag 7 (freeze)
8 (freeze noack)
9 (freeze clear)
10 (frz. cl. noack)
22 (assign class)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited quantity)
17, 28 (index)
129 (response)
00, 01 (start-stop)
17, 28 (index) (see
Note 2)
Frozen
Counter(Variation 0
is used to request
defaultvariation)
1 (read)
22 (assign class)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited quantity)
17, 28 (index)
---
---
32-Bit Frozen
Counter
1 (read)
22 (assign class)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited quantity)
17, 28 (index)
129 (response)
00, 01 (start-stop)
17, 28 (index) (see
Note 2)
16-Bit Frozen
Counter
1 (read)
22 (assign class)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited quantity)
17, 28 (index)
129 (response)
00, 01 (start-stop)
17, 28 (index) (see
Note 2)
32-Bit Frozen
1 (read)
Counter without Flag 22 (assign class)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited quantity)
17, 28 (index)
129 (response)
00, 01 (start-stop)
17, 28 (index) (see
Note 2)
10
1 (read)
16-Bit Frozen
Counter without Flag 22 (assign class)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited quantity)
17, 28 (index)
129 (response)
00, 01 (start-stop)
17, 28 (index) (see
Note 2)
Counter Change
Event (Variation 0 is
used to request
default variation)
1 (read)
---
---
32-Bit Counter
Change Event
1 (read)
129 (response)
130 (unsol. resp.)
17, 28 (index)
16-Bit Counter
Change Event
1 (read)
129 (response)
130 (unsol. resp.)
17, 28 (index)
32-Bit Counter
Change Event with
Time
1 (read)
129 (response)
130 (unsol. resp.)
17, 28 (index)
16-Bit Counter
Change Event with
Time
1 (read)
129 (response)
130 (unsol. resp.)
17, 28 (index)
Frozen Counter
Event (Variation 0 is
used to request
default variation)
1 (read)
---
---
32-Bit Frozen
Counter Event
1 (read)
129 (response)
130 (unsol. resp.)
17, 28 (index)
16-Bit Frozen
Counter Event
1 (read)
129 (response)
130 (unsol. resp.)
17, 28 (index)
32-Bit Frozen
Counter Event with
Time
1 (read)
129 (response)
130 (unsol. resp.)
17, 28 (index)
16-Bit Frozen
Counter Event with
Time
1 (read)
129 (response)
130 (unsol. resp.)
17, 28 (index)
4-11
DNP IMPLEMENTATION
OBJECT
REQUEST
RESPONSE
OBJECT
NO.
VARIATION
NO.
DESCRIPTION
FUNCTION
CODES (DEC)
QUALIFIER CODES
(HEX)
30
Analog Input
(Variation 0 is used
to request default
variation)
1 (read)
22 (assign class)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited quantity)
17, 28 (index)
---
---
1 (read)
22 (assign class)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited quantity)
17, 28 (index)
129 (response)
00, 01 (start-stop)
17, 28 (index) (see
Note 2)
1 (read)
22 (assign class)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited quantity)
17, 28 (index)
129 (response)
00, 01 (start-stop)
17, 28 (index) (see
Note 2)
1 (read)
22 (assign class)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited quantity)
17, 28 (index)
129 (response)
00, 01 (start-stop)
17, 28 (index) (see
Note 2)
1 (read)
22 (assign class)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited quantity)
17, 28 (index)
129 (response)
00, 01 (start-stop)
17, 28 (index) (see
Note 2)
1 (read)
22 (assign class)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited quantity)
17, 28 (index)
129 (response)
00, 01 (start-stop)
17, 28 (index) (see
Note 2)
Analog Change
Event (Variation 0 is
used to request
default variation)
1 (read)
---
---
32-Bit Analog
Change Event
without Time
1 (read)
129 (response)
130 (unsol. resp.)
17, 28 (index)
16-Bit Analog
Change Event
without Time
1 (read)
129 (response)
130 (unsol. resp.)
17, 28 (index)
32-Bit Analog
Change Event with
Time
1 (read)
129 (response)
130 (unsol. resp.)
17, 28 (index)
16-Bit Analog
Change Event with
Time
1 (read)
129 (response)
130 (unsol. resp.)
17, 28 (index)
1 (read)
129 (response)
130 (unsol. resp.)
17, 28 (index)
1 (read)
129 (response)
130 (unsol. resp.)
17, 28 (index)
Analog Input
1 (read)
Reporting Deadband
(Variation 0 is used
to request default
variation)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited quantity)
17, 28 (index)
---
---
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited quantity)
17, 28 (index)
129 (response)
00, 01 (start-stop)
17, 28 (index) (see
Note 2)
2 (write)
00, 01 (start-stop)
07, 08 (limited quantity)
17, 28 (index)
---
---
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited quantity)
17, 28 (index)
129 (response)
00, 01 (start-stop)
17, 28 (index) (see
Note 2)
32
34
4-12
DNP IMPLEMENTATION
OBJECT
OBJECT
NO.
REQUEST
VARIATION
NO.
DESCRIPTION
RESPONSE
FUNCTION
CODES (DEC)
QUALIFIER CODES
(HEX)
2 (write)
00, 01 (start-stop)
07, 08 (limited quantity)
17, 28 (index)
---
---
50
00, 01 (start-stop)
06 (no range, or all)
07 (limited qty=1)
08 (limited quantity)
17, 28 (index)
129 (response)
00, 01 (start-stop)
17, 28 (index) (see
Note 2)
52
129 (response)
07 (limited quantity)
---
---
60
Class 0, 1, 2, and 3
Data
1 (read)
06 (no range, or all)
20 (enable unsol)
21 (disable unsol)
22 (assign class)
---
---
Class 0 Data
1 (read)
22 (assign class)
---
---
Class 1 Data
1 (read)
20 (enable unsol)
---
---
Class 2 Data
21 (disable unsol)
---
---
Class 3 Data
22 (assign class)
---
---
Internal Indications
1 (read)
00, 01 (start-stop)
(index =7)
129 (response)
00, 01 (start-stop)
2 (write)
(see Note 3)
00 (start-stop)
(index =7)
---
---
---
---
---
No Object (function
code only)
---
---
No Object (function
code only)
23 (delay meas.)
---
---
80
FASTPATH:
---
1.
A default variation refers to the variation response when variation 0 is requested and/
or in class 0, 1, 2, or 3 scans. The default variations for object types 1, 2, 20, 21, 22, 23,
30, and 32 are selected via relay settings. This optimizes the class 0 poll data size.
2.
Cold restarts are implemented the same as warm restarts the 8 Series relay is not
restarted, but the DNP process is restarted.
4-13
DNP IMPLEMENTATION
4-14
GE
Grid Solutions
The binary inputs points for the DNP protocol, or the MSP points for IEC 60870-5-104
protocol, can be configured to a maximum of 96 points. The data source for each point is
user-programmable and can be configured by assigning FlexLogic operands.
The menu for the binary input points (DNP) or MSP points (IEC 60870-5-104) is shown
below.
5-1
Path: Setpoints > Device > Communications > DNP/IEC104 Point Lists > Binary Input/MSP
Points
Point 95 Entry
Off
IP Points
Up to 32 analog input points can be configured for the DNP or IEC 60870-5-104 protocols.
The menu for the analog input point (DNP) or MME points (IEC 60870-5-104) is shown
below.
Path: Setpoints > Device > Communications > DNP/IEC104 Point Lists > Analog Input / MME
Points
..\Analog Input / MME Points\Analog Input Point 0
Item Name
Value
Unit
Analog IP Point 0 Entry
Off
Point 0 Scale Factor
/1
Point 0 Deadband
30000
5-2
values. DNP object 34 points can be used to change deadband values from the default
for each individual DNP analog input point. Whenever power is removed and re-applied
to the 8 Series relay the new deadbands are in effect.
The binary output points for the DNP protocol, or the CSC/CDC points for IEC 60870-5-104
protocol, can be configured to a maximum of 16 points. The data source for each point is
user-programmable and can be configured by assigning FlexLogic operands. The menu
for the binary output points (DNP) or CSC/CDC points (IEC 60870-5-104) is shown below.
Path: Setpoints > Device > Communications > DNP/IEC104 Point Lists > Binary Output /
CSC/CDC Points
OP Points
FASTPATH:
The DNP / IEC 60870-5-104 point lists always begin with point 0 and end at the first Off
value. Since DNP / IEC 60870-5-104 point lists must be in one continuous block, any points
assigned after the first Off point are ignored.
BINARY INPUT POINTS
The DNP binary input data points are configured through the DNP / IEC104 POINT LISTS
BINARY INPUT / MSP POINTS menu. When a freeze function is performed on a binary
counter point, the frozen value is available in the corresponding frozen counter point.
BINARY INPUT POINTS
Static (Steady-State) Object Number: 1
Change Event Object Number: 2
Request Function Codes supported: 1 (read), 22 (assign class)
Static Variation reported when variation 0 requested: 2 (Binary Input with status),
Configurable
Change Event Variation reported when variation 0 requested: 2 (Binary Input Change
with Time), Configurable
Change Event Scan Rate: 8 times per power system cycle
Change Event Buffer Size: 1024
Default Class for All Points: 1
POINT NAME/DESCRIPTION COUNTERS
The following details lists both Binary Counters (Object 20) and Frozen Counters (Object 21).
When a freeze function is performed on a Binary Counter point, the frozen value is
available in the corresponding Frozen Counter point. 8 Series relay Digital Counter values
are represented as 16 or 32-bit integers. The DNP 3.0 protocol defines counters to be
unsigned integers. Care should be taken when interpreting negative counter values.
BINARY COUNTERS
Static (Steady-State) Object Number: 20
Change Event Object Number: 22
5-3
Request Function Codes supported: 1 (read), 7 (freeze), 8 (freeze noack), 9 (freeze and
clear), 10 (freeze and clear, noack), 22 (assign class)
Static Variation reported when variation 0 requested: 1 (32-Bit Binary Counter with
Flag)
Change Event Variation reported when variation 0 requested: 1 (32-Bit Counter
Change Event without time)
Change Event Buffer Size: 10
Default Class for all points: 3
FROZEN COUNTERS
Static (Steady-State) Object Number: 21
Change Event Object Number: 23
Request Function Codes supported: 1 (read)
Static Variation reported when variation 0 requested: 1 (32-Bit Frozen Counter with
Flag)
Change Event Variation reported when variation 0 requested: 1 (32-Bit Counter
Change Event without time)
Change Event Buffer Size: 10
Default Class for all points: 3
BINARY AND FROZEN COUNTERS POINT INDEX NAME/DESCRIPTION
0 Digital Counter 1
1 Digital Counter 2
2 Digital Counter 3
3 Digital Counter 4
4 Digital Counter 5
5 Digital Counter 6
6 Digital Counter 7
7 Digital Counter 8
8 Digital Counter 9
9 Digital Counter 10
10 Digital Counter 11
11 Digital Counter 12
12 Digital Counter 13
13 Digital Counter 14
14 Digital Counter 15
15 Digital Counter 16
ANALOG INPUTS
It is important to note that 16-bit and 32-bit variations of analog inputs are transmitted
through DNP as signed numbers. Even for analog input points that are not valid as
negative values, the maximum positive representation is 32767 for 16-bit values and
2147483647 for 32-bit values. This is a DNP requirement. The deadbands for all Analog
Input points are in the same units as the Analog Input quantity. For example, an Analog
Input quantity measured in volts has a corresponding deadband in units of volts. Relay
settings are available to set default deadband values according to data type. Deadbands
for individual Analog Input Points can be set using DNP Object 34.
FASTPATH:
5-4
1.
A default variation refers to the variation response when variation 0 is requested and/
or in class 0, 1, 2, or 3 scans. The default variations for object types 1, 2, 20, 21, 22, 23,
30, and 32 are selected via relay settings. This optimizes the class 0 poll data size.
2.
Cold restarts are implemented the same as warm restarts the 8 Series relay is not
restarted, but the DNP process is restarted.
5-5
5-6
GE
Grid Solutions
IEC 60870-5-104
FASTPATH:
In 8 Series relay both DNP and IEC104 protocol can work at the same time, but the user
has to consider that there is only one point map. So, the two protocols use the same data
mapping, i.e., same point index and same point source.
The 8 Series relay supports up to two IEC104 client connections simultaneously.
Path: Setpoints > Device > Communications > IEC 60870-5-104
..\Communications\IEC 60870-5-104
Item Name
Value
Unit
Channel 1 Port
Network - TCP
Channel 2 Port
Network - TCP
Common Address of ASDU
0
Client Address 1
0. 0. 0. 0
Client Address 2
0. 0. 0. 0
TCP Port Number 1
2404
TCP Port Number 2
2404
Cyclic Data Period
60
s
Object Info Addrs Bnry
1000
Object Info Addrs Analog
2000
Object Info Addrs Countrs
3000
Object Info Addrs Cmnd
4000
Object Info Analog Param
5000
By default the Object Information Address for the different data is as follows:
M_SP (Single Points) = 1000
M_ME (Measured value) = 2000
M_IT (Integrated Totals) = 3000
C_SC or C_DC (Single or Double Command) = 4000
P_ME_NB (Parameter of measured value) = 5000
Each Measured value has a Parameter of measured value (P_ME_NB) associated to its
threshold.
6-1
INTEROPERABILITY
The IEC 60870-5-104 Deadbands settings are used to determine when to trigger
spontaneous responses containing M_ME_NB_1 analog data. Each setting represents the
threshold value for each M_ME_NB_1 analog point.
For example, to trigger spontaneous responses from the 8 Series relay when a current
value changes by 15 A, the Analog Point xx Deadband setting should be set to 15. Note
that these settings are the default values of the deadbands. P_ME_NB_1 (parameter of
measured value, scaled value) points can be used to change threshold values, from the
default, for each individual M_ME_NB_1 analog point. There are three ways to send the
measurands to the Master station. The measurands are part of the General Group and
Group 2, so when a general interrogation or group 2 interrogation takes place all the
measurands are included in the response. Also, there is a cyclic data period setting where
it is configured in the scan period to send the measurands to the Master. And the last way,
is by sending spontaneously when a deadband overflow takes place. The IEC104 Channels
sub-menu is shown below.
Commands are executed over the Binary Outputs. The first 8 Binary Outputs are
configured to receive Select/Operate Commands and the next 8 Binary Outputs are
configured to receive Direct Execute Commands.
The IEC104 CHANNEL 1 PORT and IEC104 CHANNEL 2 PORT settings select the
communications port assigned to the IEC104 protocol for each channel. When this setting
is set to Network - TCP, the IEC104 protocol can be used over TCP/IP on channels 1 or 2.
The IEC104 NETWORK CLIENT ADDRESS settings can force the 8 Series relay to respond
to a maximum of two specific IEC104 masters which own the configured IP Addresses. The
settings in this sub-menu are shown below.
FASTPATH:
IEC104 Channel 1 Port takes the Port Number 1 and Client Address 1 to allow or reject
connections. The same method is used by channel 2.
GROUPS OF DATA
The data is organized into groups in order to provide values when the controlling station
requests them by a general or group interrogation.
Group 1 is set by the 96 Single Points (M_SP).
Group 2 is set by the 32 Measured values (M_ME).
Group 3 is set by the 32 Measured thresholds (P_ME).
These 96 Single Points and 32 Measured Values are also sent as a response to a General
Interrogation.
The Integrated Totals (M_IT) has its own Counter Group 1, and it is sent as a response to a
General Request Counter.
Interoperability
This document is adapted from the IEC 60870-5-104 standard. For this section the boxes
indicate the following: used in the standard direction; not used.
IEC 60870-5-104 Interoperability Document
System or device:
System definition.
Controlling station definition (master).
Controlled station definition (slave).
Application layer:Transmission mode for application data:Mode 1 (least significant octet
first), as defined in Clause 4.10 of IEC 60870-5-4, is used exclusively in this companion
standard.Common address of ASDU:
6-2
INTEROPERABILITY
Mnemonic
M_SP_NA_1
M_DP_NA_1
M_ST_NA_1
M_BO_NA_1
M_ME_NA_1
M_ME_NB_1
M_ME_NC_1
M_IT_NA_1
M_SP_NA_1
M_ME_ND_1
M_SP_TB_1
M_DP_TB_1
M_ST_TB_1
M_BO_TB_1
M_ME_TD_1
M_ME_TE_1
<36> := Measured value, short floating point value with time tag CP56Time2a M_ME_TF_1
<37> := Integrated totals with time tag CP56Time2a
M_IT_TB_1
M_EP_TD_1
M_EP_TE_1
<40> := Packed output circuit information of protection equipment with time M_EP_TF_1
tag CP56Time2a
Mnemonic
C_SC_NA_1
C_DC_NA_1
C_RC_NA_1
C_SE_NA_1
C_SE_NB_1
C_SE_NC_1
C_BO_NA_1
C_SC_TA_1
C_DC_TA_1
C_RC_TA_1
6-3
INTEROPERABILITY
Number / description
Mnemonic
<61> := Set point command, normalized value with time tag CP56Time2a
C_SE_TA_1
<62> := Set point command, scaled value with time tag CP56Time2a
C_SE_TB_1
<63> := Set point command, short floating point value with time tag
CP56Time2a
C_SE_TC_1
C_BO_TA_1
Either the ASDUs of the set <45> to <51> or of the set <58> to <64> are used.
Table 6-3: System information in monitor direction
Number / description
Mnemonic
M_EI_NA_1
Mnemonic
C_IC_NA_1
C_CI_NA_1
C_RD_NA_1
C_CS_NA_1
C_RP_NA_1
C_TS_TA_1
Mnemonic
PE_ME_NA_1
PE_ME_NB_1
PE_ME_NC_1
PE_AC_NA_1
Mnemonic
F_FR_NA_1
F_SR_NA_1
F_SC_NA_1
F_LS_NA_1
F_AF_NA_1
<125> := Segment
F_SG_NA_1
F_SC_NB_1
6-4
Number
Cause of transmission
Periodic, cyclic
Background scan
Spontaneous
Initialized
Request or requested
INTEROPERABILITY
Number
Cause of transmission
Activation
Activation confirmation
Deactivation
Deactivation confirmation
10
Activation termination
11
12
13
File transfer
20
21 to 36
37
38 to 41
44
45
46
47
Cause of transmission
No.
Mnemonic
<1>
M_SP_NA_1
<2>
M_SP_TA_1
<3>
M_DP_NA_1
<4>
M_DP_TA_1
<5>
M_ST_NA_1
<6>
M_ST_TA_1
<7>
M_BO_NA_1
<8>
M_BO_TA_1
<9>
M_ME_NA_1
<10>
M_ME_TA_1
<11>
M_ME_NB_1
<12>
M_ME_TB_1
<13>
M_ME_NC_1
<14>
M_ME_TC_1
<15>
M_IT_NA_1
<16>
M_IT_TA_1
<17>
M_EP_TA_1
<18>
M_EP_TB_1
<19>
M_EP_TC_1
<20>
M_PS_NA_1
<21>
M_ME_ND_1
<30>
M_SP_TB_1
<31>
M_DP_TB_1
<32>
M_ST_TB_1
<33>
M_BO_TB_1
<34>
M_ME_TD_1
10 11 12 13 20 37 44 45 46 47
to to
36 41
6-5
INTEROPERABILITY
Type identification
Cause of transmission
No.
Mnemonic
<35>
M_ME_TE_1
<36>
M_ME_TF_1
<37>
M_IT_TB_1
<38>
M_EP_TD_1
<39>
M_EP_TE_1
<40>
M_EP_TF_1
<45>
C_SC_NA_1
<46>
C_DC_NA_1
<47>
C_RC_NA_1
<48>
C_SE_NA_1
<49>
C_SE_NB_1
<50>
C_SE_NC_1
<51>
C_BO_NA_1
<58>
C_SC_TA_1
<59>
C_DC_TA_1
<60>
C_RC_TA_1
<61>
C_SE_TA_1
<62>
C_SE_TB_1
<63>
C_SE_TC_1
<64>
C_BO_TA_1
<70>
M_EI_NA_1*)
10 11 12 13 20 37 44 45 46 47
to to
36 41
<100> C_IC_NA_1
<101> C_CI_NA_1
<102> C_RD_NA_1
<103> C_CS_NA_1
<104> C_TS_NA_1
<105> C_RP_NA_1
<106> C_CD_NA_1
<107> C_TS_TA_1
<110> P_ME_NA_1
<111> P_ME_NB_1
<112> P_ME_NC_1
<113> P_AC_NA_1
<120> F_FR_NA_1
<121> F_SR_NA_1
<122> F_SC_NA_1
<123> F_LS_NA_1
<124> F_AF_NA_1
<125> F_SG_NA_1
<126> F_DR_TA_1*)
<127> F_SC_NB_1*)
FASTPATH:
* blank or X only
Basic application functions:
6-6
INTEROPERABILITY
Station initialization:
Remote initialization.
Cyclic data transmission:
Cyclic data transmission.
Read procedure:
Read procedure.
Spontaneous transmission:
Spontaneous transmission.
Double transmission of information objects with cause of transmission spontaneous:
The following type identifications may be transmitted in succession caused by a single
status change of an information object. The particular information object addresses for
which double transmission is enabled are defined in a project-specific list.
Single point information: M_SP_NA_1, M_SP_TA_1, M_SP_TB_1, and M_PS_NA_1.
Double point information: M_DP_NA_1, M_DP_TA_1, and M_DP_TB_1.
Step position information: M_ST_NA_1, M_ST_TA_1, and M_ST_TB_1.
Bitstring of 32 bits: M_BO_NA_1, M_BO_TA_1, and M_BO_TB_1 (if defined for a specific
project).
Measured value, normalized value: M_ME_NA_1, M_ME_TA_1, M_ME_ND_1, and
M_ME_TD_1.
Measured value, scaled value: M_ME_NB_1, M_ME_TB_1, and M_ME_TE_1.
Measured value, short floating point number: M_ME_NC_1, M_ME_TC_1, and
M_ME_TF_1.
Station interrogation:
Group 1.
Group 2.
Group 3.
Group 4.
Group 5.
Group 6.
Group 7.
Group 8.
Group 9.
Group 10.
Group 11.
Group 12.
Group 13.
Group 14.
Group 15.
Group 16.
Global.
Clock synchronization:
Clock synchronization (optional, see Clause 7.6).
Day of week used.
RESI, GEN (time tag substituted/not substituted)
SU-bit (summertime) used.
Command transmission:
Direct command transmission.
Direct setpoint command transmission.
Select and execute command.
6-7
INTEROPERABILITY
6-8
INTEROPERABILITY
Parameter
Default value
t0
Remarks
Selected value
N/A
t1
15 s
15 s
t2
10 s
10 s
t3
20 s
20 s
Default value
Remarks
12 APDUs
Selected value
8 APDUs
8 APDUs
Value
Remarks
Port number
2404
In all cases
6-9
INTEROPERABILITY
6-10
GE
Grid Solutions
IEC 60870-5-103
The point map for the 103 is different from the one shared by the IEC104 and DNP
protocols. IEC 60870-5-103 serial communications protocol is supported on the rear RS485
port only.
The DNP, 103 and Modbus can not be enabled simultaneously. Only one instance of
DNP3.0, IEC 103 or Modbus can run on the RS485 serial port.
Path: Setpoints > Device > Communications > IEC60870-5-103
To view the list of binary inputs, see the 8 Series relay Flexlogic Operands table in the
Setpoints/ FlexLogic section of the individual 8 Series relay instruction manual.
FASTPATH:
FASTPATH:
The user must pay attention when configuring the function type and information number
of the different points, because they must be unique. There is no mechanism in the
EnerVista 8 Series Setup software or the front panel HMI to detect duplication of the
information index.
The IEC 60870-5-103 point lists always begin with point 0 and end at the first Off value.
Since IEC 60870-5-103 point lists must be in one continuous block, any points assigned
after the first Off point are ignored.
Cause of Transmission
The cause of transmission is an unsigned integer which takes one of the values specified in
the following tables.
Table 7-1: Cause of Transmission in the Monitor Direction
Value
Description
<1>
Spontaneous
<2>
Cyclic
<3>
<4>
<5>
Start/Restart
<6>
Power on
<8>
Time synchronization
7-1
COMMUNICATIONS MENUS
Value
Description
<9>
General interrogation
<10>
<20>
<21>
Nack of command
Description
<8>
Time synchronization
<9>
<20>
General command
Communications Menus
The following show the menus and sub-menus for the 103 protocols.
PATH: SETPOINTS > DEVICE > COMMUNICATIONS > IEC 60870-5-103 PROTOCOL
Range: 0 to 254 in steps of 1
n IEC 60870-5-103
IEC103 COMMON ASDU
n PROTOCOL
ADDRS
Message
PATH: SETPOINTS > DEVICE > COMMUNICATIONS > IEC103 POINT LISTS
IEC103
POINT LISTS
BINARY INPUTS
Message
MEASURANDS
Message
COMMANDS
PATH: SETPOINTS > DEVICE > COMMUNICATIONS > IEC103 POINT LISTS > BINARY INPUTS
BINAR< INPUTS
7-2
Message
Message
Point 0:
off
Message
Message
Message
Point 95:
off
TM
TM
COMMUNICATIONS MENUS
PATH: SETPOINTS > DEVICE > COMMUNICATIONS > IEC103 POINT LISTS > MEASURANDS
MEASURANDS
FIRST ASDU
SECOND ASDU
THIRD ASDU
FOURTH ASDU
First ASDU
Ident Type: 0
Range: 3, 9
Default: 3
Message
First ASDU
Func Type: 0
Message
First ASDU
Info Num: 0
Message
First ASDU
Scan Timeout: 0 s
Message
Message
Range:
to 65.535
in steps
Range:0.000
0 to 255
in steps
of 1 of 0.001
Default:
Default:00
Message
Range:
toin
+32767
in steps
of 1
Range: -32768
0 to 255
steps of
1
Default:
Default: 00
Message
Message
Ninth
AnalogFactor:
Factor:
First Analog
0
Range:0.000
0 to 255
in steps
of 1 of 0.001
Range:
to 65.535
in steps
Default:00
Default:
Message
NinthAnalog
First
AnalogFactor:
Offset:
0
Range: -32768
Range:
0 to 255
toin
+32767
steps of
in steps
1
of 1
Default: 00
Default:
7-3
INTEROPERABILITY
PATH: SETPOINTS > DEVICE > COMMUNICATIONS > IEC103 POINT LISTS > COMMANDS
COMMANDS
Message
Message
Command 0 ON:
off
Message
Command 0 OFF:
off
Message
Message
First Analog31
Factor:
Command
Info Num:
0
Message
Command
ON:
First Analog31
Factor:
off
0
Message
Command 31 OFF:
off
TM
TM
TM
0 to 255 in
steps
of 1
Range: FlexLogic
operand
0
Default: Off
Interoperability
Physical layer
Electrical interface
Optical interface
Transmission speed
EIA RS-485
32
Glass fibre
Plastic fibre
9600 bits/s
19200 bits/s
Link layer
There are no choices for the Link Layer.
7-4
INTEROPERABILITY
Application layer
Transmission mode
for application data
Common address of
ASDU
Mode 1 (least significant octet first), is used exclusively in this companion standard.
Selection of standard
information numbers
in monitor direction
Semantics
<0>
<0>
Time synchronization
<2>
Reset FCB
<3>
Reset CU
<4>
Start/restart
<5>
Power on
Semantics
<16>
Auto-recloser active
<17>
Teleprotection active
<18>
Protection active
<19>
LED reset
<20>
<21>
Test mode
<22>
<23>
Characteristic 1
<24>
Characteristic 2
<25>
Characteristic 3
<26>
Characteristic 4
<27>
Auxiliary input 1
<28>
Auxiliary input 2
<29>
Auxiliary input 3
<30>
Auxiliary input 4
8 Series relay
Identifier
8 Series relay
Data Text
Semantics
<32>
Measurand supervision I
<33>
Measurand supervision V
<35>
<36>
<37>
<38>
VT fuse failure
8 Series relay
Identifier
8 Series relay
Data Text
7-5
INTEROPERABILITY
INF
Semantics
<39>
Teleprotection disturbed
<46>
Group warning
<47>
Group alarm
8 Series relay
Identifier
8 Series relay
Data Text
8 Series relay
Identifier
8 Series relay
Data Text
8 Series relay
Identifier
8 Series relay
Data Text
Semantics
<48>
Earth fault L1
<49>
Earth fault L2
<50>
Earth fault L3
<51>
<52>
7-6
INF
Semantics
<64>
Start / pick-up L1
<65>
Start / pick-up L2
<66>
Start / pick-up L3
<67>
Start / pick-up N
<68>
General trip
<69>
Trip L1
<70>
Trip L2
<71>
Trip L3
<72>
<73>
<74>
<75>
<76>
<77>
<78>
Zone 1
<79>
Zone 2
<80>
Zone 3
<81>
Zone 4
<82>
Zone 5
<83>
Zone 6
<84>
<85>
Breaker failure
<86>
<87>
<88>
<89>
<90>
Trip I>
<91>
Trip I>>
<92>
Trip IN>
<93>
Trip IN>>
INTEROPERABILITY
Semantics
<128>
CB on by AR
<129>
CB on by long-time AR
<130>
AR blocked
8 Series relay
Identifier
8 Series relay
Data Text
8 Series relay
Identifier
8 Series relay
Data Text
Semantics
<144>
Measurand I
<145>
Measurands I, V
<146>
Measurands I, V, P, Q
<147>
<148>
Selection of standard
information numbers
in control direction
INF
Semantics
<240>
<241>
<243>
<244>
<245>
<249>
<250>
<251>
Semantics
<0>
<0>
Time synchronization
Semantics
<16>
Auto-recloser on / off
<17>
Teleprotection on / off
<18>
Protection on / off
<19>
LED reset
<23>
Activate characteristic 1
<24>
Activate characteristic 2
<25>
Activate characteristic 3
<26>
Activate characteristic 4
Semantics
<240>
<241>
<243>
<244>
<245>
7-7
INTEROPERABILITY
Basic application
functions
INF
Semantics
<248>
Write entry
<249>
<250>
<251>
Test mode
Disturbance data
Generic services
Private data
Miscellaneous
Measurand
7-8
or
2,4
Current L1
Current L2
Current L3
Voltage L1-E
Voltage L2-E
Voltage L3-E
Active power P
Reactive power Q
Frequency f
Voltage L1-L2
GE
Grid Solutions
IEC 61850
The optional communications processor supports both the IEC61850 GOOSE and IEC
61850 MMS Server service as per IEC 61850 standard Ed. 2. The GOOSE messaging service
provides the 8 Series relay unit the ability to Publish/Subscribe Digital Input Status and its
Quality and Timestamp to/from other IEDs with supporting GOOSE messaging service,
while the server support allows remote control center, RTU/Gateway, local HMI or other
client role devices access to the relay for monitoring and control. The configuration of
IEC61850 services is accomplished using the 8 Series relay configuration software,
EnerVista 8 Series Setup software. A rebooting MUST be done before any changes made
take affect.
General
IEC61850 SERVER
The IEC 61850 Server (i.e., 8 Series relay) reports data to the IEC 61850 Client, such as Local
HMI, RTU and Gateway with the information of logical device, data sets, data control block,
logical nodes and their data attributes.
The following tables list the logical nodes and number of instances for each of the LNs that
are supported within the 8 Series relay.
LOGICAL NODES
Table 8-1: Communications Elements in the 8 Series relay
8 Series relay Communications Elements
Port status
LCCH (3)
Remote Device
LGOS (8)
LTMS
Time management
LTIM
LPHD
Yes
Logical Node 0
LLN0
Yes
Yes
8-1
GENERAL
Table 8-2: Protection and Protection Related Elements in the 8 Series relay
8 Series relay Protection Elements
850
869
889
GGIO
GGIO(6)
GGIO(6)
GGIO(6)
GGIO(6)
MMXU
MMXU(3)
MMXU(2)
MMXU(1)
MMXU(5)
MSQI
MSQI(3)
MSQI(1)
MSQI(1)
MSQI(4)
MMXN
CIRCUIT BREAKER
XCBR
XCBR(3)
XCBR(1)
XCBR(1)
XCBR(2)
BREAKER FAILURE
RBRF
RBRF(3)
RBRF(1)
RBRF(1)
RFRF(2)
SYNCHROCHECK
RSYN
AUTORECLOSING
RREC
PTOC
PTOC(3)
PTOC(2)
PTOC(1)
PTOC(2)
PIOC
PIOC(8)
PIOC(2)
PIOC(2)
PIOC(6)
RDIR
RDIR(1)
RDIR(1)
RDIR(1)
RDIR(1)
PTOC
PTOC(3)
PTOC(2)
PTOC(1)
PTOC(2)
PIOC
PIOC(6)
PIOC(2)
PIOC(2)
PIOC(3)
RDIR
RDIR(1)
RDIR(1)
RDIR(1)
RDIR(1)
PTOC
PTOC(3)
PTOC(1)
PTOC(1)
PTOC(2)
PIOC
PIOC(6)
PIOC(1)
PIOC(2)
PIOC(2)
RDIR
RDIR(1)
RDIR(1)
RDIR(1)
PTOC
PTOC(1)
PTOC(1)
PIOC
PIOC(1)
PIOC(1)
RDIR
RDIR(1)
RDIR(1)
PTOC
PTOC(3)
PTOC(1)
PTOC(1)
PIOC(3)
PIOC(3)
PIOC(1)
PIOC(1)
RDIR
PTUV
PTUV(2)
PTUV(2)
PTUV(2)
PTUV(2)
PTUV
PTUV(2)
PTUV(2)
PTUV(2)
PTUV(2)
PTOV
PTOV(1)
PTOV(1)
PTOV(1)
PTOV(2)
PTOV
PTOV(2)
PTOV(2)
PTOV(2)
PTOV(2)
PTOV
PTOV(1)
PTOV(1)
PTOV(1)
PTOV(1)
PTOV(2)
PTOV(1)
PTOV(1)
PTOV(1)
VT FUSE FAIL
TVTR
TVTR(1)
TVTR(1)
TVTR(1)
TVTR(1)
PDOP
PDOP(2)
PDOP(2)
PDOP(2)
PDOP(2)
PTUF
PTUF(4)
PTUF(6)
PTUF(4)
PTUF(4)
OVERFREQUENCY 1 -2(81O)
PTOF
PTOF(2)
PTOF(4)
PTOF(2)
PTOF(2)
THERMAL OVERLOAD
PTTR
PFRC
PFRC(4)
PFRC(6)
PFRC(2)
PFRC(2)
POWER FACTOR 1
POPF
FAULT LOCATOR
RFLO
RREC(1)
RDIR(1)
PIOC(3)
RDIR(1)
RFLO(15)
CURRENT LEVEL
MANUAL CLOSE BLOCKING
LOAD ENCROACHMENT
COLD LOAD PICKUP
BUS TRANSFER
UNDERVOLTAGE RESTORATION
8-2
GENERAL
850
869
889
UNDERFREQUENCY RESTORATION
EARTH LEAKAGE
PHIZ
NOTE:
NOTE
TRIP BUS
PTRC
PTRC(6)
PTRC(6)
PTRC(6)
PTRC(6)
RTD
TTMP
TTMP(13)
TTMP(13)
TTMP(13)
TTMP(13)
W1 Xfmr Overload
PTTR
PTTR(1)
PTTR
PTTR(1)
PDIF
PDIF(1)
PDIF
PDIF(1)
PVPH
PVPH(2)
PVPH(2)
PHASE REVERSAL
PTOV(1)
PTOV(1)
CURRENT UNBALANCE
PTOC(2)
PTOC(2)
ACCELERATION TIME
PTOC(1)
LOAD INCREASE
PTOC(1)
GROUND FAULT
PIOC(2)
MECHANICAL JAM
PIOC(1)
SHORT CIRCUIT
PIOC(1)
THERMAL MODEL
PTTR(1)
RESTART INHIBITED
PMRI(1)
UNDERPOWER
PDUP(2)
UNDERCURRENT
PTUC(2)
STATOR DIFFERENTIAL
PDIF(1)
PTOC(1)
PTUV(1)
PDIF(1)
PDIF(1)
LOSS OF EXCITATION
PDIS(2)
OOS
PPAM(1)
THERMAL OVERLOAD
PTTR(1)
INADVERTENT ENERGIZATION
PIOC(1)
OFFLINE OVERCURRENT
PIOC(1)
8-3
FUNCTIONALITY
Data Obj
data attribute
PhyHealth
Type
FC
ENS
stVal
ENUMERATED
Name
Description
This physical devices health
ST
Each logical node within the preceding tables support all mandatory attributes in addition
to the optional data attributes (that are supported within the protection element). See
figure PDIF Class.
Figure 8-1: PDIF Class
Functionality
CLIENT CONNECTIONS
The 8 Series relay supports up to four IEC61850 concurrent client connections.
LOGICAL DEVICES AND REPORTS
Supported buffered and un-buffered report, the report triggers are shown in the
Supported Triggers list.
Supported Triggers
Data-change
Integrity
General-interrogation
Supported buffered and un-buffered report option fields are shown in the Field list.
Field
8-4
Sequence number
Data-ref
Conf- revision
Report control block configuration settings are modified from IEC61850 advanced
configurator writing directly in a CID file. There is no Modbus register assigned to those.
The datasets for reports are fully configurable with CDCs from any Logical Node.
The Description field in the LN is fixed text and it can not be updated from the Modbus
settings.
2.
Configuration
Configure the 8 Series relay (having order code option: IEC 61850) through the
Device Setup or Quick connect screen.
The IEC 61850 Configurator tree item is displayed after Maintenance. See figure
below.
Select the required settings from the different tab displays (in the configurator
screen) to complete the IEC 61850 configuration.
Select any online relay and right click on the selected tree item. More options
become available for selection, as shown in the next examples.
8-5
Read Device Settings: The menu option reads all the settings from the relay by TFTP
and creates an 8 Series relay file with extension *.CID. The created *.CID file consists of
two sections. A private section where all non IEC 61850 settings are available, and a
public section in which IEC 61850 related settings are implemented.
FASTPATH:
When creating a CID file using a 3rd party ICT/SCL tool, the user must ensure the following:
The order code in the CID file must match the device order code if writing the CID
file directly into the relay (without using the Enervista software). The "Desc" value
in communication settings of the CID file must match the relays order code.
The maximum allowed services must be equal or below the specified limits as in
ICD/CID.
8-6
ICD/CID
ICD/CID
Settings
Reports
GOOSE Reception
GOOSE Transmission
Select the ICD/CID tab in the IEC 61850 Configurator window. The ICD/CID tab consists of
the ICD Explorer window to the left side of the view. The ICD Explorer window allows the
user to navigate through the data model of the relay and change desired IEC 61850
parameters such as the Logical Device Name, MMS port and others.
Select a parameter in the ICD Explorer window to open the Attributes window in the
right part of the screen.
8-7
2.
In the Attributes window, double click in the Value column of the table and enter the
new value for that parameter.
For example, from the Attributes window the user can set the IED name, description,
and configuration version for the Logical Device, see preceding figure.
Parameters
IP, IP-Subnet, IP-Gateway: The parameters are the configured IP details in the device.
OSI parameters: The parameters must be configured according to the IEC 61850
standard.
MMS TCP Port Number: The range of the setting is 1 to 65535, in steps of 1. The setting
allows the user to change the TCP port number for MMS connections.
TCP Connection timeout: The range of the setting is 10 to 1800 s, in steps of 10. The
setting is useful for detecting fail IEC 61850 connections. The timer must be
application specific for IEC 61850. If there is no data traffic on an established TCP
connection for more than this setting time, the connection is disconnected from the
server.
GOOSE Transmission on port -4 and port-5 (which are the 2 fiber optic ports available)
is configurable. The user can choose either port or both of the ports for GOOSE
transmissions and receptions. The logical nodes displayed under the GEDevice >
8 Series relay tree (see figure below) are shown based on the order code. If a
8-8
particular order code does not support certain protection and control functions, the
respective logical node is not shown in the list.
Settings
The Settings tab consists of General Settings, DAI Settings tab, and GGIO1 Indications tab.
1.
General Settings
IED NameRange:
Up to 64 alphanumeric characters
The IED Name represents the MMS domain name (IEC 61850 logical device) where all
IEC/MMS logical nodes are located. Valid characters for these values are upper and
lowercase letters, numbers, and the underscore (_) character, and the first character
in the string must be a letter. This conforms to the IEC 61850 standard.
LDevice inst
Range: Up to 64 alphanumeric characters
The setting represents the MMS domain name (IEC 61850 logical device) where all IEC/
MMS logical nodes are located. Valid characters for these values are upper and
lowercase letters, numbers, and the underscore (_) character. The first character in the
string must be a letter. This conforms to the IEC 61850 standard.
2.
8-9
DAI settings contains these features for configuration: MMXU & MSQI logical nodes,
GGIO3 logical node, XCBR logical node.
MMXU & MSQI Logical nodes
Range: 1 to 100.000 %
The MMXU & MSQI deadband settings represent the deadband values used to
determine when to update the MMXU mag and cVal values from the associated
instmag and instcVal values. The mag and cVal values are used for the IEC
61850 buffered and unbuffered reports. The settings correspond to the associated
db data items in the CF functional constraint of the MMXU logical node, as per the
IEC 61850 standard. According to IEC 61850-7-3, the db value shall represent the
percentage of difference between the maximum and minimum in units of 0.001%.
Thus, it is important to know the maximum value for each MMXU measured quantity,
since this represents the 100.00% value for the deadband.
MIN/MAX VALUES FOR MMXU NODES
The equations to calculate minimum (min) and maximum (max) values in the MMXU
nodes are as follows:
Table 8-3: Calculate Min/Max MMXU Node Values
MMXU Node Value
To Calculate
TotW
TotVar
TotVA
TotPF
max = 1
min = -1
Hz
max = 90
min = 0
HzRte
max = 15
min = -15
PPV
PhV
A$neut
A$net
A$res
AuxV
SeqA$c1, c2 ,c3
SeqV$c1, c2, c3
dbAng
See the following list of supported parameters for the 8 Series relay. Note that the
same list is also supported for the MSQI logical node. MSQI parameters are displayed
only if the relay supports sensitive ground CT.
8-10
Supported Parameters (names begin with 845, 850, 869, or 889 depending on the specific relay)
850.MMXU1$CF$TotW$db
850.MMXU1$CF$TotVAr$db
850.MMXU1$CF$TotVA$db
850.MMXU1$CF$TotPF$db
850.MMXU1$CF$Hz$db
850.MMXU1$CF$Hz3VT$db
850.MMXU1$CF$HzVx$db
850.MMXU1$CF$PPV$phsAB$db
850.MMXU1$CF$PPV$phsAB$dbAng
850.MMXU1$CF$PPV$phsBC$db
850.MMXU1$CF$PPV$phsBC$dbAng
850.MMXU1$CF$PPV$phsCA$db
850.MMXU1$CF$PPV$phsCA$dbAng
850.MMXU1$CF$PhV$phsA$db
850.MMXU1$CF$PhV$phsA$dbAng
850.MMXU1$CF$PhV$phsB$db
850.MMXU1$CF$PhV$phsB$dbAng
850.MMXU1$CF$PhV$phsC$db
850.MMXU1$CF$PhV$phsC$dbAng
850.MMXU1$CF$PhV$neut$db
850.MMXU1$CF$PhV$neut$dbAng
850.MMXU1$CF$A$phsA$db
850.MMXU1$CF$A$phsA$dbAng
850.MMXU1$CF$A$phsB$db
850.MMXU1$CF$A$phsB$dbAng
850.MMXU1$CF$A$phsC$db
850.MMXU1$CF$A$phsC$dbAng
850.MMXU1$CF$A$neut$db
850.MMXU1$CF$A$neut$dbAng
850.MMXU1$CF$A$net$db
850.MMXU1$CF$A$net$dbAng
850.MMXU1$CF$AuxV$db
850.MMXU1$CF$AuxV$dbAng
8-11
Reports
8-12
The Reports tab in IEC 61580 Configurator permits configuration of data sets and report
control blocks for buffered and unbuffered reports.
The screen helps the user to create, modify and delete Report Control Blocks (RCBs) and
Datasets. Each Report Control Block must have a maximum of 4 different clients up to a
maximum of 4 Report Control Blocks linked to their Datasets. Each dataset must have a
maximum of 64 elements in total.
There are two screens available in the Report tab window:
Report control block: The user can add the required report control block.
RCB Name: The first character in the value of this attribute must be a letter (upper
or lower case). The rest of the characters must be a number, a letter (upper or
lower case) or a _. The maximum number of characters allowed in IEC61850
Configurator is 30 and IEC61850 MMS Library adds 2 more characters indicating
the number of the instance of the RCB depending on the number of IEC61850
clients configured.
Dataset sources: Each report control block can be appended with dataset items in the
screen using a drag and drop operation.
8-13
Add Report button and Remove Report button: Both buttons are in the lower side of
the screen.
Note that a Report control block can also be added by right clicking 845 (or your
relay model number) which is under the GEDevice tree.
Save button and Cancel button: Click the Save button to save all configured settings.
Click the Cancel button to discard the modifications just made to the configuration.
8-14
1.
2.
In the New Report Control Block window under Select Report Type, select the radio
button for a buffered or unbuffered report.
3.
In the IEC61850 Clients N# dropdown list, select 1 or any other available number.
4.
Click the Next button to proceed with further configuration (else click Cancel to
discard the new configuration).
5.
In the Select DataSet window, select the radio button for New DataSet or Existing
DataSet.
Report Properties
The report properties section can be viewed when any configured report available under
GEDevice > 8 Series relay is selected.
Figure 8-6: Report Properties Window
8-15
All the available parameters of the Report control block are displayed when clicking
Report Advanced Configuration. Respective OptFields, TrgOps can be configured by
either selecting True or False. Buffer time is given in milliseconds.
Figure 8-7: Advanced Configuration
Select the required logical node under GEDevice > 8 Series relay tree.
2.
3.
Drag and drop the item to the DataSet Elements section, see the following DataSet
Sources/DataSet figure.
2.
Use the up arrow if you want to shift the row to the top. Use the down arrow to
shift the row down.
8-16
Select the row in which the dataset item is to be deleted and click the x button.
Select the row in which the dataset item is to be deleted then right click and select the
displayed Delete FCDA option.
Goose Transmission
Buffered Report
Unbuffered Report
Total Reports
The 8 Series relay has an IEC 61850 server and supports the GOOSE message scheme. A
maximum of three GOOSE control blocks can be added. The GOOSE Configuration has two
sections:
Transmission
Reception
8-17
8-18
GOOSE Tx control blocks: The user can add the required GOOSE control block.
Control Block Name: The first character in the value of this attribute must be a
letter (upper or lower case). The rest of the characters must be a number, a letter
(upper or lower case) or a _. The maximum number of characters allowed is 32.
Ethertype App ID: All characters must be numerical. The maximum number of
characters allowed is 4. IEC61850 Configurator allows characters limited to 0 to
9, A to F and it saves in the CID file the hexadecimal value (max FFFF).
Dataset sources: Each GOOSE control block can be appended with dataset items in
this screen using a drag and drop operation.
DataSet Name: The first character in the value of this attribute must be a letter
(upper or lower case). The rest of the characters must be a number, a letter (upper
or lower case) or a _. The maximum number of characters allowed is 32.
Add GOOSE Control Block button and Remove GOOSE Control Block button: Both
buttons are in the lower side of the screen.
Note that a GOOSE Control block can also be added by right clicking on 845 (or your
relay model number) which is under the GEDevice tree.
The Remove Goose Control Block button deletes a configured existing Goose control
block.
8-19
Note that the Goose control block can also be deleted by right clicking on the
configured existing report.
Save button and Cancel button: Click the Save button to save all configured settings.
Click the Cancel button to discard the modifications just made to the configuration.
2.
The Tx GOOSE control block is added under GEDevice>889 (or your relay model
number) tree node with a default Control block name.
Goose Tx Properties
The properties section can be viewed on selecting any configured GOOSE block available
under GEDevice >889 (or your relay model number).
Figure 8-16: Goose TX Properties Screen
8-20
Time to live (ms): The range of the setting is 1000 to 60000 in steps of 1000
Multicast MAC: The standard MAC address limit. Make sure to configure the MAC with
the least significant bit in the most significant byte, set to 1.
Example:
01: 0C: CD: 00: 00: 04
2.
Use the up arrow if you want to shift the row to the top. Use the down arrow to
shift the row down.
Select the row in which the dataset item is to be deleted and click the x button.
Select the row in which the dataset item is to be deleted then right click and select the
displayed Delete FCDA option.
Number of DAs
Depending on the configured dataset items, the Number of DAs counter increases
automatically.
8-21
Goose Reception
The 8 Series relay can receive Transmitted GOOSE from any IED in GOOSE Reception. For
proper GOOSE reception the relay must be configurated as described in this section. A
maximum of eight IEDs can be added.
GOOSE Reception has two sections:
Mapping to Remote Inputs: Each subscribed GOOSE dataset item can be appended in
the screen using the drag and drop method.
Add IED button and Remove IED button: Both buttons are in the lower side of the
screen.
Note that IED can also be added by right clicking in the IED List section.
Save button and Cancel button: Click the Save button to save all configured settings.
Click the Cancel button to discard the modifications just made to the configuration.
8-22
1.
Select the dataset item being subscribed under the required IED which is available in
Template > LDInst > GOOSEOut 1 tree.
2.
3.
Drag and drop the chosen dataset item to the Mapping to Remote Inputs section as
shown in the figure: Mapping to Remote Inputs.
Select the row in which the dataset item is being deleted then right click and select the
Delete Entry button.
IED Count
Depending on the configured dataset items for IEDs, the IED count increases
automatically. In addition, the GOOSE Id field is updated with the GOOSE ID of the
subscriber relay.
Figure 8-24: IED Count
8-23
8-24
GE
Grid Solutions
The base offering of 8 Series relay supports Trivial File Transfer Protocol (TFTP). The default
port 69 is always used. No configuration setting is available. When the communications
module is present, SSH File Transfer Protocol (SFTP) is also available. The default TCP port
22 for SSH is used for SFTP as well.
9-1
9-2
GE
Grid Solutions
Modbus Protocol
All Ethernet ports and serial communication ports support the Modbus protocol. The only
exception is if the serial port has been configured for DNP or IEC 60870-5-103 operation
(see descriptions below). This allows the EnerVista 8 Series Setup software (which is a
Modbus master application) to communicate to the 8 Series relay.
The 8 Series relay implements a subset of the Modicon Modbus RTU serial communication
standard. The Modbus protocol is hardware-independent. That is, the physical layer can be
any of a variety of standard hardware configurations. This includes USB, RS485, fiber
optics, etc. Modbus is a single master / multiple slave type of protocol suitable for a multidrop configuration.
The 8 Series relay is always a Modbus slave with a valid slave address range 1 to 254.
DATA FRAME FORMAT AND DATA RATE
One data frame of an asynchronous transmission to or from an 8 Series relay typically
consists of 1 start bit, 8 data bits, and 1 stop bit. This produces a 10-bit data frame. This is
important for transmission through modems at high bit rates. Modbus protocol can be
implemented at any standard communication speed. The 8 Series relay supports
operation at 9600, 19200, 38400, 57600, and 115200 bps baud rate. The USB interface
supports ModBus TCP/IP.
FUNCTION CODE SUPPORTED
The following functions are supported by the 8 Series relay:
When a ModBus master such as the EnerVista 8 Series Setup software communicates to
the 8 Series relay over Ethernet, the 8 Series relay slave address, TCP port number and the
8 Series relay IP address for the associated port must be configured and are also
configured within the Master for this device. The default ModBus TCP port number is 502.
10-1
MODBUS PROTOCOL
Exception
Description
01
ILLEGAL FUNCTION
02
03
Modbus Protocol
Function Code 03H
Modbus Implementation: Read Holding Registers
8 Series relay Implementation: Read Setpoints
For the 8 Series relay implementation of Modbus, the function code can be used to read
any setpoints (holding registers). Holding registers are 16 bit (two byte) values
transmitted high order byte first. As a result all 8 Series relay Setpoints are sent as two
bytes. The maximum number of registers that can be read in one transmission is 125.
The slave response to this function code is the slave address, function code, a count of the
number of data bytes to follow, the data itself and the CRC. Each data item is sent as a two
byte number with the high order byte sent first.
For example, consider a request for slave 17 to respond with 3 registers starting at address
006B. For this example the register data in these addresses is as follows:
10-2
MODBUS PROTOCOL
Address
Data
006B
022B
006C
0000
006D
0064
BYTES
EXAMPLE
DESCRIPTION
SLAVE ADDRESS
11
FUNCTION CODE
03
read registers
00 6B
NUMBER OF SETPOINTS
00 03
CRC
76 87
BYTES
EXAMPLE
DESCRIPTION
SLAVE ADDRESS
11
FUNCTION CODE
03
read registers
BYTE COUNT
06
3 registers = 6 bytes
02 2B
00 00
00 64
CRC
54 83
BYTES
EXAMPLE
DESCRIPTION
SLAVE ADDRESS
11
FUNCTION CODE
04
read registers
00 08
00 01
1 register = 2 bytes
CRC
B2 98
BYTES
EXAMPLE
DESCRIPTION
SLAVE ADDRESS
11
FUNCTION CODE
04
read registers
10-3
MODBUS PROTOCOL
SLAVE RESPONSE
BYTES
EXAMPLE
DESCRIPTION
BYTE COUNT
02
1 register = 2 bytes
00 00
CRC
78 F3
BYTES
EXAMPLE
DESCRIPTION
SLAVE ADDRESS
11
FUNCTION CODE
05
execute operation
OPERATION CODE
00 01
operation code 1
CODE VALUE
FF 00
perform function
CRC
DF 6A
BYTES
EXAMPLE
DESCRIPTION
SLAVE ADDRESS
11
FUNCTION CODE
05
execute operation
OPERATION CODE
00 01
operation code 1
CODE VALUE
FF 00
perform function
CRC
DF 6A
10-4
MASTER TRANSMISSION
BYTES
EXAMPLE
DESCRIPTION
SLAVE ADDRESS
11
FUNCTION CODE
06
04 5C
setpoint address 04 5C
DATA
00 02
CRC
CB B9
MODBUS PROTOCOL
BYTES
EXAMPLE
DESCRIPTION
SLAVE ADDRESS
11
FUNCTION CODE
06
04 5C
setpoint address 04 5C
DATA
00 02
CRC
CB B9
BYTES
EXAMPLE
DESCRIPTION
SLAVE ADDRESS
11
FUNCTION CODE
07
CRC
4C 22
BYTES
EXAMPLE
DESCRIPTION
SLAVE ADDRESS
11
FUNCTION CODE
07
DEVICE STATUS
(see following table)
2C
CRC
22 28
Description
Bit 0
SP Group 3 Active
Bit 1
SP Group 2 Active
Bit 2
Pickup State
Bit 3
Breaker Connected
Bit 4
Breaker Closed
Bit 5
Breaker Tripped
Bit 6
Alarm
Bit 7
Trip
10-5
MODBUS PROTOCOL
BYTES
EXAMPLE
DESCRIPTION
SLAVE ADDRESS
11
FUNCTION CODE
08
loopback test
DIAG CODE
00 00
must be 00 00
DATA
00 00
must be 00 00
CRC
E0 0B
BYTES
EXAMPLE
DESCRIPTION
SLAVE ADDRESS
11
FUNCTION CODE
08
loopback test
DIAG CODE
00 00
must be 00 00
DATA
00 00
must be 00 00
CRC
E0 0B
Data
04 5C
00 02
04 5D
01 F4
BYTES
EXAMPLE
DESCRIPTION
SLAVE ADDRESS
11
FUNCTION CODE
10
store setpoints
04 5C
setpoint address 04 5C
NUMBER OF SETPOINTS
00 02
BYTE COUNT
04
4 bytes of data
DATA 1
00 02
DATA 2
01 F4
CRC
31 11
10-6
SLAVE RESPONSE
BYTES
EXAMPLE
DESCRIPTION
SLAVE ADDRESS
11
FUNCTION CODE
10
store setpoints
MODBUS PROTOCOL
SLAVE RESPONSE
BYTES
EXAMPLE
DESCRIPTION
04 5C
setpoint address 04 5C
NUMBER OF SETPOINTS
00 02
2 setpoints
CRC
82 7A
Value to be written
DEC
HEX
DEC
HEX
62242
F322
16740
4164
62243
F323
28009
6D69
62244
F324
28265
6E69
62245
F325
29556
7374
62246
F326
29281
7261
62247
F327
29807
746F
62248
F328
29184
7200
62249
F329
0000
62250
F32A
0000
62251
F32B
0000
62252
F32C
0000
62253
F32D
12288
3000
62254
F32E
0000
62255
F32F
0000
62256
F330
0000
62257
F331
0000
62258
F332
0000
62259
F333
0000
62260
F334
0000
62261
F335
0000
62262
F336
0000
62263
F337
0000
FE
10
F322
0016
2C
10-7
MODBUS PROTOCOL
3000
HEX
Command Register
40129
0x0080
40130
0x0081
Value Description
Reset
96
98
Clear Events
105
4096
Function
Data Starting
Address
Number of
Setpoints
Byte count
Data 1
Data 2
FE
10
0080
0002
04
0005
0060
Table 10-22: Function Format for Clear Energy Use Data command
Slave #
Function
Data Starting
Address
Number of
Setpoints
Byte count
Data 1
Data 2
FE
10
0080
0002
04
0005
0069
Function
Data Starting
Address
Number of
Setpoints
Byte count
Data 1
Data 2
FE
10
0080
0002
04
0005
1000
10-8
Master Transmission
Byte#
Example
Description
Slave Address
FE
Function Code
05
execute operation
Operation Code
00 01
operation code
Code Value
FF 00
perform function
CRC
DF 6A
MODBUS PROTOCOL
Value Description
Reset
96
98
Clear Events
105
4096
Function
Operation Code
Code Value
FE
05
0001
FF00
10-9
MODBUS PROTOCOL
10-10
GE
Grid Solutions
11-1
A Register Index area (40524 to 40648) that contains 125 Actual Values register
addresses
2.
A Register area (30524 to 30648) that contains the data at the addresses in the
Register Index
Register data that is separated in the rest of the memory map may be re-mapped to
adjacent register addresses in the user-definable registers area. This is accomplished by
writing to register addresses in the user-definable register index area. This allows for
improved throughput of data and can eliminate the need for multiple read command
sequences. The user-definable register index is stored as a setpoint and therefore it is
remembered even when the power is removed.
Default User Map
Common actual values have been defaulted for the user. Below are the default registers.
Table 11-1: Default User Map
11-2
Description
Modbus Address
Device Status
30712
30713
LED Status
30708
30709
30700
30701
30706
30707
30714
30715
30718
30719
30728
30729
30736
30737
Ia
31270
31271
Ib
31272
31273
Description
Modbus Address
Ic
31274
31275
In
31278
31279
Iavg
31295
31296
Ig
31276
31277
The 8 Series relay supports 32-bit Modbus items to be configured in the user map. When
such an address is configured in the user map for example at user map address 1, user
map address 2 is also consumed by the same item irrespective of the address assigned in
address 2.
Address Range
Description
Product ID
0000h to 007Fh
Commands
0080h to 00FFh
User Map
0100h to 01FFh
Actual Values
0200h to 0FFFh
Setpoints
1000h to 1FFFh
Reserved
3000h to 3FFFh
4000h to FFFFh
Reserved.
Reading CO Outputs
CO Outputs are used to show the state of the output relays in the 8-Series device (internal
to the device). For example, on the 869 relay the Trip and Close contacts have voltage
monitoring inputs. The Trip and Close Circuit Monitoring feature uses the voltage input to
monitor the trip and to close coil circuit integrity.
11-3
To read the output relay status for all relays, use Modbus address 30706 (0x02C1) where
each bit corresponds to a different output relay as described in format code FC198.
Table 11-3: Modbus Map entry, CO Outputs
Modbus Hex
Address Address
Description
Min
Max
Step Units
Format Factory
Code
Default
Size in
Words
8 8 8 8
5 6 8 4
0 9 9 5
30706
CO Outputs
0xFFFFFFFF
FC198
Y Y Y Y
0x02C1
Type
Definition
FC126A
unsigned 16 bits
Off / On Selection
0
1
unsigned 32 bits
FC198
850
869
889
845
Off
On
Each bit corresponds to a particular output relay, and uses format FC126A
0x00000004
Output Relay 3
0x00000008
Output Relay 4
0x00000010
Output Relay 5
0x00000020
Output Relay 6
0x00000040
Output Relay 7
These Modbus Registers are listed in the Modbus memory map table as follows:
Table 11-5: Modbus Map entries, Element Status Register for Breaker Control Relays
Modbus Hex
Address Address
Description
Min
Max
Step Units
Format Factory
Code
Default
30765
0x02FC
65535
FE020
Y Y Y Y
30766
0x02FD
65535
FE021
Y Y Y Y
30767
0x02FE
65535
FE022
Y Y Y Y
30768
0x02FF
65535
FE023
Y Y Y Y
30769
0x0300
65535
FE024
Y Y Y Y
30770
0x0301
65535
FE025
Y Y Y Y
30771
0x0302
65535
FE026
Y Y Y Y
11-4
Size in
Words
8 8 8 8
5 6 8 4
0 9 9 5
The format code used for each Modbus register is listed in the Format Code column. In this
case, the format codes used are FE020 through FE026.
These format codes are described in the Format Code table as follows:
Table 11-6: Format Code entries, Element Status Register for Breaker Control Relays
Code
Type
Definition
FE020
unsigned 16 bits
0x0002
0x0004
unsigned 16 bits
0x0002
FE021
FE022
FE023
FE024
FE025
FE026
NOTE:
NOTE
850
869
889
845
Von
Voff
Von
0x0004
Voff
unsigned 16 bits
0x0002
Von
0x0004
Voff
unsigned 16 bits
0x0002
Von
0x0004
Voff
unsigned 16 bits
0x0002
Von
0x0004
Voff
unsigned 16 bits
0x0002
Von
0x0004
Voff
unsigned 16 bits
0x0002
Critical Fail OP
From the notes preceding the full Format Code table, notice that Element Status Format
Codes (FE1 onwards) contain values that should be masked with 0x01FF to match the bit
field values shown in the table.
Element Status 20 monitors the state of the voltage monitor for Breaker Control Relay
1.
When the voltage is present on the Trip Contact voltage monitor (Von), the Element Status
20 register will read: 0x2002 (8194). The masked value is then 0x0002, corresponding to
Von in the preceding table.
When the voltage is not present on the Trip Contact voltage monitor (Voff), the Element
Status 20 register will read: 0x2004 (8196). The masked value is then 0x0004,
corresponding to Voff in the preceding table.
Element Status 21 monitors the state of the voltage monitor for Breaker Control Relay
2.
When the voltage is present on the Trip Contact voltage monitor (Von), the Element Status
21 register will read: 0x2002 (8194). The masked value is then 0x0002, corresponding to
Von in the preceding table.
When the voltage is not present on the Trip Contact voltage monitor (Voff), the Element
Status 21 register will read: 0x2004 (8196). The masked value is then 0x0004,
corresponding to Voff in the preceding table.
Element Status 26 is used to monitor the Critical Fail contact.
11-5
When the relay is in service, the "IN SERVICE" LED on the front panel is green.
The Element Status 26 (Critical Fail) register reads: 0x2000 (8192). The masked value is then
0x0000, indicating Critical Fail Op is not present.
When the relay is not service, the "IN SERVICE" LED on the front panel is orange.
The Element Status 26 (Critical Fail) register reads: 0x2002 (8194). The masked value is then
0x0002, corresponding to Cristical Fail Op in the preceding table.
These Modbus Registers are listed in the Modbus memory map table as follows:
Table 11-7: Modbus Map entries for Phase Currents
Modbus Hex
Address Address
Description
Min
Max
Step Units
31270
0x04F5
J1 Ia
0xFFFFFFFF 1
31272
0x04F7
J1 Ib
0xFFFFFFFF 1
31274
0x04F9
J1 Ic
0xFFFFFFFF 1
Format Factory
Code
Default
Size in
Words
8 8 8 8
5 6 8 4
0 9 9 5
F13
Y Y Y Y
F13
Y Y Y Y
F13
Y Y Y Y
In this case the format code used is F13, which is described in the Format Code table as
follows:
Table 11-8: Format Code entries for Phase Current
Code
Type
Definition
F13
unsigned 32 bits
1st 16 bits
2nd 16 bits
The phase current metering values read by the PLC should match the values shown on the
relay. Validating the received values in the PLC against the real values observed on the 850
relay front panel or read via 8 Series Enervista Setup is recommended.
PLCs can use two different word orders for reading 32-bit registers. As a result, a 32 bit
value of aabbccdd may be read as aabb ccdd, or as ccdd aabb.
A word-swap may be necessary to read the proper data from 850 relay current registers.
Once the correct word order is set, the obtained value needs to be divided by 1000 to get
the decimal point.
Register: 31270
Register: 312701
For example:
Phase A Current value on relay display: 183.594 A
Phase current values read from Phase A Current Modbus registers:
04F5 (31270): 0002
04F6 (31271): CD2A
11-6
Combine the two 16 bit values into a 32 bit unsigned value: 183594
Apply the decimal point rule (divide by 1000): 183.594 A
Register: 31270
Register: 312701
0002
CD2A
183594
183.594
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
Actual Values
Product Information
30001
0x0000
Product Code
65535
F0
Y Y Y Y
30002
0x0001
Hardware Revision
26
FC110
Y Y Y Y
30003
0x0002
Firmware Version
65535
F2
160
Y Y Y Y
30005
0x0004
Boot
65535
F2
Y Y Y Y
30006
0x0005
Firmware Date
0x010107D8
0x0C1F082E
F53
16844760 2
Y Y Y Y
30008
0x0007
Firmware Time
0x173B3B63
F54
Y Y Y Y
30010
0x0009
Boot Date
0x010107D8
0x0C1F082E
F53
16844760 2
Y Y Y Y
30012
0x000B
Boot Time
0x173B3B63
F54
Y Y Y Y
30014
0x000D
Product Serial #
65535
F60_12
Serial
Y Y Y Y
30021
0x0014
Order Code
65535
F60_34
OrderCode 17
30038
0x0025
MAC Address 1
65535
F60_6A
Y Y Y Y
30047
0x002E
65535
F2
Y Y Y Y
Y Y Y Y
30049
0x0030
Boot
65535
F2
Y Y Y Y
30050
0x0031
0x010107D8
0x0C1F082E
F53
16844760 2
Y Y Y Y
30052
0x0033
0x173B3B63
F54
Y Y Y Y
30054
0x0035
Boot Date
0x010107D8
0x0C1F082E
F53
16844760 2
Y Y Y Y
30056
0x0037
Boot Time
0x173B3B63
F54
Y Y Y Y
30058
0x0039
MAC Address 1
65535
F60_6A
Y Y Y Y
30061
0x003C
MAC Address 2
65535
F60_6A
Y Y Y Y
30067
0x0042
0xFFFFFFFF
F71
Y Y Y Y
30069
0x0044
IO F CPLD
0xFFFFFFFF
F71
Y Y Y Y
30071
0x0046
IO G CPLD
0xFFFFFFFF
F71
Y Y Y Y
30075
0x004A
AN J CPLD
0xFFFFFFFF
F71
Y Y Y Y
30077
0x004C
AN K CPLD
0xFFFFFFFF
F71
Y Y Y Y
30079
0x004E
Display CPLD
0xFFFFFFFF
F71
Y Y Y Y
Time
30241
0x00F0
Time
0x173B3B63
F54
Y Y Y Y
30243
0x00F2
Date
0x010107D8
0x0C1F082E
F53
16844760 2
Y Y Y Y
30245
0x00F4
RTC Time
0xFFFFFFFF
F52
Y Y Y Y
30247
0x00F6
System Clock
0xFFFFFFFF
F52
Y Y Y Y
11-7
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
Targets
30257
0x0100
65535
F60_32
16
Y Y Y Y
30273
0x0110
Target Count
256
F0
Y Y Y Y
30274
0x0111
Target Cause
0xFFFFFFFF
FC134
Y Y Y Y
FC342
Y Y Y Y
F60_8A
Y Y Y Y
F30
Y Y Y Y
PTP Status
30300
0x012B
30301
0x012C
Grandmaster ID
65535
30305
0x0130
RTC Accuracy
-999999999
999999999
30307
0x0132
FC343
Y Y Y Y
30308
0x0133
FC343
Y Y Y Y
65535
F0
Y Y Y Y
ns
0x020B
30525
0x020C
65535
F0
Y Y Y Y
30526
0x020D
65535
F0
Y Y Y Y
30527
0x020E
65535
F0
Y Y Y Y
30528
0x020F
65535
F0
Y Y Y Y
30529
0x0210
65535
F0
Y Y Y Y
30530
0x0211
65535
F0
Y Y Y Y
30531
0x0212
65535
F0
Y Y Y Y
30532
0x0213
65535
F0
Y Y Y Y
30533
0x0214
65535
F0
Y Y Y Y
30534
0x0215
65535
F0
Y Y Y Y
30535
0x0216
65535
F0
Y Y Y Y
30536
0x0217
65535
F0
Y Y Y Y
30537
0x0218
65535
F0
Y Y Y Y
30538
0x0219
65535
F0
Y Y Y Y
30539
0x021A
65535
F0
Y Y Y Y
30540
0x021B
65535
F0
Y Y Y Y
30541
0x021C
65535
F0
Y Y Y Y
30542
0x021D
65535
F0
Y Y Y Y
30543
0x021E
65535
F0
Y Y Y Y
30544
0x021F
65535
F0
Y Y Y Y
30545
0x0220
65535
F0
Y Y Y Y
30546
0x0221
65535
F0
Y Y Y Y
30547
0x0222
65535
F0
Y Y Y Y
30548
0x0223
65535
F0
Y Y Y Y
30549
0x0224
65535
F0
Y Y Y Y
30550
0x0225
65535
F0
Y Y Y Y
30551
0x0226
65535
F0
Y Y Y Y
30552
0x0227
65535
F0
Y Y Y Y
30553
0x0228
65535
F0
Y Y Y Y
30554
0x0229
65535
F0
Y Y Y Y
30555
0x022A
65535
F0
Y Y Y Y
30556
0x022B
65535
F0
Y Y Y Y
30557
0x022C
65535
F0
Y Y Y Y
11-8
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
30558
0x022D
65535
F0
30559
0x022E
65535
F0
Y Y Y Y
30560
0x022F
65535
F0
Y Y Y Y
30561
0x0230
65535
F0
Y Y Y Y
30562
0x0231
65535
F0
Y Y Y Y
30563
0x0232
65535
F0
Y Y Y Y
30564
0x0233
65535
F0
Y Y Y Y
30565
0x0234
65535
F0
Y Y Y Y
30566
0x0235
65535
F0
Y Y Y Y
30567
0x0236
65535
F0
Y Y Y Y
30568
0x0237
65535
F0
Y Y Y Y
30569
0x0238
65535
F0
Y Y Y Y
30570
0x0239
65535
F0
Y Y Y Y
30571
0x023A
65535
F0
Y Y Y Y
30572
0x023B
65535
F0
Y Y Y Y
30573
0x023C
65535
F0
Y Y Y Y
30574
0x023D
65535
F0
Y Y Y Y
30575
0x023E
65535
F0
Y Y Y Y
30576
0x023F
65535
F0
Y Y Y Y
30577
0x0240
65535
F0
Y Y Y Y
30578
0x0241
65535
F0
Y Y Y Y
30579
0x0242
65535
F0
Y Y Y Y
30580
0x0243
65535
F0
Y Y Y Y
30581
0x0244
65535
F0
Y Y Y Y
30582
0x0245
65535
F0
Y Y Y Y
30583
0x0246
65535
F0
Y Y Y Y
30584
0x0247
65535
F0
Y Y Y Y
30585
0x0248
65535
F0
Y Y Y Y
30586
0x0249
65535
F0
Y Y Y Y
30587
0x024A
65535
F0
Y Y Y Y
30588
0x024B
65535
F0
Y Y Y Y
30589
0x024C
65535
F0
Y Y Y Y
30590
0x024D
65535
F0
Y Y Y Y
30591
0x024E
65535
F0
Y Y Y Y
30592
0x024F
65535
F0
Y Y Y Y
30593
0x0250
65535
F0
Y Y Y Y
30594
0x0251
65535
F0
Y Y Y Y
30595
0x0252
65535
F0
Y Y Y Y
30596
0x0253
65535
F0
Y Y Y Y
30597
0x0254
65535
F0
Y Y Y Y
30598
0x0255
65535
F0
Y Y Y Y
30599
0x0256
65535
F0
Y Y Y Y
30600
0x0257
65535
F0
Y Y Y Y
30601
0x0258
65535
F0
Y Y Y Y
30602
0x0259
65535
F0
Y Y Y Y
Y Y Y Y
11-9
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
30603
0x025A
65535
F0
30604
0x025B
65535
F0
Y Y Y Y
30605
0x025C
65535
F0
Y Y Y Y
30606
0x025D
65535
F0
Y Y Y Y
30607
0x025E
65535
F0
Y Y Y Y
30608
0x025F
65535
F0
Y Y Y Y
30609
0x0260
65535
F0
Y Y Y Y
30610
0x0261
65535
F0
Y Y Y Y
30611
0x0262
65535
F0
Y Y Y Y
30612
0x0263
65535
F0
Y Y Y Y
30613
0x0264
65535
F0
Y Y Y Y
30614
0x0265
65535
F0
Y Y Y Y
30615
0x0266
65535
F0
Y Y Y Y
30616
0x0267
65535
F0
Y Y Y Y
30617
0x0268
65535
F0
Y Y Y Y
30618
0x0269
65535
F0
Y Y Y Y
30619
0x026A
65535
F0
Y Y Y Y
30620
0x026B
65535
F0
Y Y Y Y
30621
0x026C
65535
F0
Y Y Y Y
30622
0x026D
65535
F0
Y Y Y Y
30623
0x026E
65535
F0
Y Y Y Y
30624
0x026F
65535
F0
Y Y Y Y
30625
0x0270
65535
F0
Y Y Y Y
30626
0x0271
65535
F0
Y Y Y Y
30627
0x0272
65535
F0
Y Y Y Y
30628
0x0273
65535
F0
Y Y Y Y
30629
0x0274
65535
F0
Y Y Y Y
30630
0x0275
65535
F0
Y Y Y Y
30631
0x0276
65535
F0
Y Y Y Y
30632
0x0277
65535
F0
Y Y Y Y
30633
0x0278
65535
F0
Y Y Y Y
30634
0x0279
65535
F0
Y Y Y Y
30635
0x027A
65535
F0
Y Y Y Y
30636
0x027B
65535
F0
Y Y Y Y
30637
0x027C
65535
F0
Y Y Y Y
30638
0x027D
65535
F0
Y Y Y Y
30639
0x027E
65535
F0
Y Y Y Y
30640
0x027F
65535
F0
Y Y Y Y
30641
0x0280
65535
F0
Y Y Y Y
30642
0x0281
65535
F0
Y Y Y Y
30643
0x0282
65535
F0
Y Y Y Y
30644
0x0283
65535
F0
Y Y Y Y
30645
0x0284
65535
F0
Y Y Y Y
30646
0x0285
65535
F0
Y Y Y Y
30647
0x0286
65535
F0
Y Y Y Y
11-10
Y Y Y Y
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
30648
65535
F0
Y Y Y Y
F50
Y Y Y Y
F51
Y Y Y Y
0x0287
Event Recorder
30660
0x0293
0xFFFFFFFF
30662
0x0295
999999
30664
0x0297
1024
F10
Y Y Y Y
Y Y Y Y
us
0x02BB
CI Inputs 1-32
0xFFFFFFFF
FC194
30706
0x02C1
CO Outputs
0xFFFFFFFF
FC198
Y Y Y Y
30708
0x02C3
LEDs 1-16
0xFFFFFFFF
FC300
Y Y Y Y
30710
0x02C5
LED 17
0xFFFFFFFF
FC301
Y Y Y Y
30712
0x02C7
Device Status
0xFFFFFFFF
FC135
Y Y Y Y
30714
0x02C9
0xFFFFFFFF
F10
Y Y Y Y
30722
0x02D1
0xFFFFFFFF
F10
Y Y Y Y
30734
0xFFFFFFFF
FC191
Y Y Y Y
30746
0x02E9
65535
FE001
Y Y Y Y
30747
0x02EA
65535
FE002
Y Y Y Y
30748
0x02EB
65535
FE003
Y Y Y Y
30749
0x02EC
65535
FE004
Y Y Y Y
30750
0x02ED
65535
FE005
Y Y Y Y
30751
0x02EE
65535
FE006
Y Y Y Y
30752
0x02EF
65535
FE007
Y Y Y Y
30753
0x02F0
65535
FE008
Y Y Y Y
30754
0x02F1
65535
FE009
Y Y Y Y
30755
0x02F2
65535
FE010
Y Y Y Y
30756
0x02F3
Element Status 11
(Security Status)
65535
FE011
Y Y Y Y
30757
0x02F4
Element Status 12
(Targets Active)
65535
FE012
Y Y Y Y
30758
0x02F5
65535
FE013
Y Y Y Y
30759
0x02F6
65535
FE014
Y Y Y Y
30760
0x02F7
65535
FE015
Y Y Y Y
30761
0x02F8
65535
FE016
Y Y Y Y
30762
0x02F9
Element Status 17
(Programmable PB 1)
65535
FE017
Y Y Y Y
30763
0x02FA
Element Status 18
(Programmable PB 2)
65535
FE018
Y Y Y Y
30764
0x02FB
Element Status 19
(Programmable PB 3)
65535
FE019
Y Y Y Y
30765
0x02FC
65535
FE020
Y Y Y Y
11-11
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
30766
0x02FD
65535
FE021
Y Y Y Y
30767
0x02FE
65535
FE022
Y Y Y Y
30768
0x02FF
65535
FE023
Y Y Y Y
30769
0x0300
65535
FE024
Y Y Y Y
30770
0x0301
65535
FE025
Y Y Y Y
30771
0x0302
65535
FE026
Y Y Y Y
30772
0x0303
Element Status 27
(Comms OK)
65535
FE027
Y Y Y Y
30773
0x0304
65535
FE028
30774
0x0305
65535
FE029
Y Y Y Y
30775
0x0306
65535
FE030
Y Y Y Y
30776
0x0307
65535
FE031
Y Y Y Y
30777
0x0308
65535
FE032
Y Y Y Y
30778
0x0309
65535
FE033
Y Y Y Y
30779
0x030A
65535
FE034
Y Y Y Y
30780
0x030B
65535
FE035
Y Y
30781
0x030C
65535
FE036
Y Y
30782
0x030D
65535
FE037
Y Y
30783
0x030E
65535
FE038
Y Y
30784
0x030F
65535
FE039
Y Y
30785
0x0310
65535
FE040
Y Y
30786
0x0311
65535
FE041
30787
0x0312
65535
FE042
30788
0x0313
65535
FE043
30789
0x0314
65535
FE044
30790
0x0315
65535
FE045
30791
0x0316
65535
FE046
30792
0x0317
Element Status 47
0
(Contactor Status Closed)
65535
FE047
30793
0x0318
Element Status 48
0
(Contactor Status Opened)
65535
FE048
11-12
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
30794
0x0319
Element Status 49
(Contactor Status
Unknown)
65535
FE049
30795
0x031A
Element Status 50
(Contactor Status
Disconnected)
65535
FE050
30796
0x031B
65535
FE051
30797
0x031C
65535
FE052
30810
0x0329
65535
FE065
30811
0x032A
Element Status 66
(Percent Differential)
65535
FE066
Y Y Y
30812
0x032B
65535
FE067
30813
0x032C
Element Status 68
(Percent Differential
Saturation)
65535
FE068
Y Y Y
30814
0x032D
65535
FE069
30815
0x032E
Element Status 70
(Percent Differential
Direction)
65535
FE070
Y Y Y
30816
0x032F
65535
FE071
30817
0x0330
Element Status 72
(Percent Differential
Warning)
65535
FE072
Y Y Y
30818
0x0331
65535
FE073
30819
0x0332
Element Status 74
(Percent Differential
Harmonic)
65535
FE074
Y Y
30820
0x0333
65535
FE075
30821
0x0334
Element Status 76
(Instantaneous
Differential)
65535
FE076
Y Y
30822
0x0335
65535
FE077
30823
0x0336
Element Status 78
(Thermal Trip)
65535
FE078
30824
0x0337
Element Status 79
(Thermal Alarm)
65535
FE079
30825
0x0338
Element Status 80
(Current Unbalance
Alarm)
65535
FE080
30826
0x0339
Element Status 81
(Current Unbalance Trip)
65535
FE081
30827
0x033A
Element Status 82
(Mechanical Jam)
65535
FE082
30828
0x033B
Element Status 83
(Undercurrent Alarm)
65535
FE083
30829
0x033C
Element Status 84
(Undercurrent Trip)
65535
FE084
30830
0x033D
Element Status 85
(Overload)
65535
FE085
Y Y
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
11-13
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
30831
0x033E
65535
FE086
30832
0x033F
65535
FE087
30833
0x0340
Element Status 88
(Ground Fault Alarm)
65535
FE088
30834
0x0341
Element Status 89
(Ground Fault Trip)
65535
FE089
30835
0x0342
Element Status 90
(Acceleration Time)
65535
FE090
30836
0x0343
Element Status 91
(Speed2 Acceleration)
65535
FE091
30837
0x0344
Element Status 92
(Underpower Alarm)
65535
FE092
30838
0x0345
Element Status 93
(Underpower Trip)
65535
FE093
30839
0x0346
Element Status 94
(Transformer Overload)
65535
FE094
30840
0x0347
65535
FE095
30841
0x0348
65535
FE096
30842
0x0349
65535
FE097
Y Y Y Y
30843
0x034A
65535
FE098
30844
0x034B
65535
FE099
30845
0x034C
65535
FE100
Y Y Y Y
30846
0x034D
65535
FE101
Y Y Y Y
30847
0x034E
65535
FE102
Y Y
30848
0x034F
65535
FE103
Y Y
30849
0x0350
65535
FE104
Y Y
30850
0x0351
65535
FE105
Y Y
30851
0x0352
65535
FE106
30852
0x0353
65535
FE107
30853
0x0354
65535
FE108
Y Y Y Y
30854
0x0355
65535
FE109
Y Y Y Y
30855
0x0356
65535
FE110
30856
0x0357
65535
FE111
30857
0x0358
65535
FE112
Y Y Y Y
30858
0x0359
65535
FE113
Y Y Y Y
11-14
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
Y Y
Y Y
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
30859
0x035A
65535
FE114
30860
0x035B
65535
FE115
30861
0x035C
65535
FE116
30862
0x035D
65535
FE117
30863
0x035E
65535
FE118
Y Y Y Y
30864
0x035F
65535
FE119
Y Y Y Y
30865
0x0360
65535
FE120
Y Y
30866
0x0361
65535
FE121
30867
0x0362
65535
FE122
Y Y Y Y
30868
0x0363
65535
FE123
Y Y
30869
0x0364
65535
FE124
30870
0x0365
65535
FE125
30871
0x0366
65535
FE126
30872
0x0367
65535
FE127
30873
0x0368
65535
FE128
Y Y
30874
0x0369
65535
FE129
30876
0x036B
65535
FE131
30878
0x036D
65535
FE133
30879
0x036E
65535
FE134
Y Y
30880
0x036F
65535
FE135
30881
0x0370
65535
FE136
30882
0x0371
65535
FE137
30883
0x0372
65535
FE138
30884
0x0373
65535
FE139
30885
0x0374
65535
FE140
Y Y Y Y
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
Y
11-15
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
30886
0x0375
65535
FE141
Y Y
30887
0x0376
65535
FE142
Y Y
30888
0x0377
65535
FE143
30889
0x0378
65535
FE144
30890
0x0379
65535
FE145
30891
0x037A
65535
FE146
30892
0x037B
65535
FE147
30893
0x037C
65535
FE148
Y Y
30894
0x037D
65535
FE149
Y Y Y Y
30895
0x037E
65535
FE150
Y Y Y Y
30896
0x037F
65535
FE151
Y Y Y Y
30897
0x0380
65535
FE152
Y Y Y Y
30898
0x0381
65535
FE153
Y Y Y Y
30899
0x0382
65535
FE154
Y Y Y Y
30900
0x0383
65535
FE155
Y Y Y Y
30901
0x0384
65535
FE156
30902
0x0385
65535
FE157
Y Y Y Y
30904
0x0387
65535
FE159
Y Y Y Y
30905
0x0388
65535
FE160
30906
0x0389
65535
FE161
Y Y
30907
0x038A
65535
FE162
Y Y
30908
0x038B
65535
FE163
Y Y Y Y
30909
0x038C
65535
FE164
Y Y Y Y
30910
0x038D
65535
FE165
30912
0x038F
65535
FE167
Y Y Y Y
30913
0x0390
65535
FE168
Y Y Y Y
30914
0x0391
65535
FE169
Y Y Y Y
11-16
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
30915
0x0392
65535
FE170
Y Y Y Y
30916
0x0393
65535
FE171
30917
0x0394
65535
FE172
30918
0x0395
65535
FE173
Y Y Y Y
30919
0x0396
65535
FE174
Y Y Y Y
30920
0x0397
65535
FE175
30921
0x0398
65535
FE176
30922
0x0399
65535
FE177
Y Y Y Y
30923
0x039A
65535
FE178
Y Y Y Y
30924
0x039B
65535
FE179
30925
0x039C
65535
FE180
30926
0x039D
65535
FE181
30927
0x039E
65535
FE182
30928
0x039F
65535
FE183
30929
0x03A0
65535
FE184
30930
0x03A1
65535
FE185
30931
0x03A2
65535
FE186
30932
0x03A3
65535
FE187
30933
0x03A4
65535
FE188
30934
0x03A5
65535
FE189
30935
0x03A6
65535
FE190
30936
0x03A7
65535
FE191
30937
0x03A8
65535
FE192
30938
0x03A9
65535
FE193
Y Y Y Y
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
11-17
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
30939
0x03AA
65535
FE194
Y Y
30940
0x03AB
65535
FE195
30941
0x03AC
65535
FE196
Y Y Y Y
30942
65535
FE197
Y Y
30943
0x03AE
65535
FE198
30944
0x03AF
65535
FE199
Y Y Y Y
30945
0x03B0
65535
FE200
Y Y
30946
0x03B1
65535
FE201
30947
0x03B2
65535
FE202
Y Y Y Y
30948
0x03B3
65535
FE203
Y Y Y Y
30949
0x03B4
65535
FE204
Y Y Y Y
30950
0x03B5
65535
FE205
Y Y Y Y
30951
0x03B6
65535
FE206
Y Y Y Y
30952
0x03B7
65535
FE207
Y Y Y Y
30953
0x03B8
65535
FE208
30954
0x03B9
65535
FE209
Y Y Y Y
30955
0x03BA
65535
FE210
Y Y Y Y
30956
0x03BB
65535
FE211
Y Y Y Y
30957
0x03BC
65535
FE212
30958
65535
FE213
30959
0x03BE
65535
FE214
Y Y Y Y
30960
0x03BF
65535
FE215
Y Y Y Y
30961
0x03C0
65535
FE216
Y Y Y Y
30962
0x03C1
65535
FE217
Y Y Y Y
30963
0x03C2
65535
FE218
Y Y Y Y
30964
0x03C3
65535
FE219
Y Y Y Y
30965
0x03C4
65535
FE220
Y Y Y Y
11-18
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
30966
0x03C5
65535
FE221
Y Y Y Y
30967
0x03C6
65535
FE222
Y Y Y Y
30968
0x03C7
65535
FE223
Y Y Y Y
30969
0x03C8
65535
FE224
Y Y Y Y
30970
0x03C9
65535
FE225
Y Y Y Y
30971
0x03CA
65535
FE226
Y Y Y Y
30972
0x03CB
65535
FE227
Y Y Y Y
30973
0x03CC
65535
FE228
Y Y Y Y
30974
65535
FE229
Y Y Y Y
30975
0x03CE
65535
FE230
Y Y Y Y
30976
0x03CF
65535
FE231
Y Y Y Y
30977
0x03D0
65535
FE232
Y Y Y Y
30978
0x03D1
65535
FE233
Y Y Y Y
30979
0x03D2
65535
FE234
Y Y Y Y
30980
0x03D3
65535
FE235
Y Y Y Y
30981
0x03D4
65535
FE236
Y Y Y Y
30982
0x03D5
65535
FE237
Y Y Y Y
30983
0x03D6
65535
FE238
Y Y Y Y
30984
0x03D7
65535
FE239
Y Y Y Y
30985
0x03D8
65535
FE240
30986
0x03D9
65535
FE241
Y Y Y Y
30987
65535
FE242
Y Y Y Y
30988
65535
FE243
Y Y Y Y
30989
65535
FE244
Y Y Y Y
30990
65535
FE245
Y Y Y Y
30991
0x03DE
65535
FE246
Y Y Y Y
30992
0x03DF
65535
FE247
Y Y Y Y
30993
0x03E0
65535
FE248
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
11-19
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
30994
0x03E1
65535
FE249
30995
0x03E2
65535
FE250
30996
0x03E3
65535
FE251
30997
0x03E4
65535
FE252
30998
0x03E5
65535
FE253
30999
0x03E6
65535
FE254
Y Y Y Y
31000
0x03E7
65535
FE255
Y Y Y Y
31001
0x03E8
65535
FE256
Y Y
31002
0x03E9
65535
FE257
31003
0x03EA
65535
FE258
31004
0x03EB
65535
FE259
Y Y
31005
0x03EC
65535
FE260
31006
0x03ED
65535
FE261
Y Y Y Y
31007
0x03EE
65535
FE262
Y Y Y Y
31008
0x03EF
65535
FE263
Y Y Y Y
31009
0x03F0
65535
FE264
Y Y Y Y
31010
0x03F1
65535
FE265
Y Y Y Y
31011
0x03F2
65535
FE266
Y Y Y Y
31012
0x03F3
65535
FE267
Y Y Y Y
31013
0x03F4
65535
FE268
Y Y
31014
0x03F5
65535
FE269
31015
0x03F6
65535
FE270
31017
0x03F8
65535
FE272
31018
0x03F9
65535
FE273
31020
0x03FB
65535
FE275
31021
0x03FC
65535
FE276
31022
0x03FD
65535
FE277
11-20
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
Y Y
Y Y
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
31023
0x03FE
65535
FE278
31024
0x03FF
65535
FE279
31025
0x0400
65535
FE280
31026
0x0401
65535
FE281
31027
0x0402
65535
FE282
31032
0x0407
65535
FE287
Y Y Y Y
31034
0x0409
65535
FE289
Y Y Y Y
31035
0x040A
65535
FE290
Y Y Y Y
31036
0x040B
65535
FE291
Y Y Y Y
31037
0x040C
65535
FE292
Y Y Y Y
31038
0x040D
65535
FE293
Y Y Y Y
31039
0x040E
65535
FE294
Y Y Y Y
31040
0x040F
65535
FE295
Y Y Y Y
31041
0x0410
65535
FE296
Y Y Y Y
31042
0x0411
65535
FE297
Y Y Y Y
31043
0x0412
65535
FE298
Y Y Y Y
31044
0x0413
65535
FE299
Y Y Y Y
31045
0x0414
65535
FE300
Y Y Y Y
31046
0x0415
65535
FE301
Y Y Y Y
31047
0x0416
65535
FE302
Y Y Y Y
31048
0x0417
65535
FE303
Y Y Y Y
31049
0x0418
65535
FE304
Y Y Y Y
31050
0x0419
65535
FE305
Y Y Y Y
31051
0x041A
65535
FE306
Y Y Y Y
31052
0x041B
65535
FE307
Y Y Y Y
31053
0x041C
65535
FE308
Y Y Y Y
31054
0x041D
65535
FE309
Y Y Y Y
31055
0x041E
65535
FE310
Y Y Y Y
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
11-21
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
31056
0x041F
65535
FE311
Y Y Y Y
31057
0x0420
65535
FE312
Y Y Y Y
31058
0x0421
65535
FE313
Y Y Y Y
31059
0x0422
65535
FE314
Y Y Y Y
31060
0x0423
65535
FE315
Y Y Y Y
31061
0x0424
65535
FE316
Y Y Y Y
31062
0x0425
65535
FE317
Y Y Y Y
31063
0x0426
65535
FE318
Y Y Y Y
31064
0x0427
65535
FE319
Y Y Y Y
31065
0x0428
65535
FE320
Y Y Y Y
31066
0x0429
65535
FE321
Y Y Y Y
31067
0x042A
65535
FE322
Y Y Y Y
31068
0x042B
65535
FE323
Y Y Y Y
31069
0x042C
65535
FE324
Y Y Y Y
31070
0x042D
65535
FE325
Y Y Y Y
31071
0x042E
65535
FE326
Y Y Y Y
31077
0x0434
65535
FE332
Y Y Y Y
31078
0x0435
65535
FE333
Y Y Y Y
31079
0x0436
65535
FE334
Y Y Y Y
31080
0x0437
65535
FE335
Y Y Y Y
31081
0x0438
65535
FE336
Y Y Y Y
31082
0x0439
65535
FE337
Y Y Y Y
31083
0x043A
65535
FE338
Y Y Y Y
31084
0x043B
65535
FE339
Y Y Y Y
31085
0x043C
65535
FE340
Y Y Y Y
31086
0x043D
65535
FE341
Y Y Y Y
31087
0x043E
65535
FE342
Y Y Y Y
31088
0x043F
65535
FE343
Y Y Y Y
11-22
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
31089
0x0440
65535
FE344
Y Y Y Y
31131
0x046A
65535
FE386
Y Y Y Y
31132
0x046B
65535
FE387
Y Y Y Y
31133
0x046C
65535
FE388
Y Y Y Y
31134
0x046D
65535
FE389
Y Y Y Y
31143
0x0476
65535
FE398
Y Y Y Y
31144
0x0477
65535
FE399
Y Y Y Y
31145
0x0478
65535
FE400
Y Y Y Y
31146
0x0479
65535
FE401
Y Y Y Y
31155
0x0482
65535
FE410
Y Y Y Y
31157
0x0484
65535
FE412
31158
0x0485
65535
FE413
31159
0x0486
65535
FE414
31160
0x0487
65535
FE415
31161
0x0488
65535
FE416
31162
0x0489
65535
FE417
31163
0x048A
65535
FE418
31164
0x048B
65535
FE419
31165
0x048C
65535
FE420
Y Y Y Y
31166
0x048D
65535
FE421
Y Y Y Y
31168
0x048F
65535
FE423
Y Y Y Y
31169
0x0490
65535
FE424
Y Y Y Y
31183
0x049E
65535
FE438
Y Y Y Y
31184
0x049F
65535
FE439
Y Y Y Y
31186
0x04A1
65535
FE441
31187
0x04A2
65535
FE442
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
11-23
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
31188
0x04A3
65535
FE443
31189
0x04A4
65535
FE444
31190
0x04A5
65535
FE445
31191
0x04A6
65535
FE446
31192
0x04A7
65535
FE447
31193
0x04A8
65535
FE448
31194
0x04A9
65535
FE449
31195
0x04AA
65535
FE450
31196
0x04AB
65535
FE451
31197
0x04AC
65535
FE452
31198
65535
FE453
31199
0x04AE
65535
FE454
31200
0x04AF
65535
FE455
31201
0x04B0
65535
FE456
31202
0x04B1
65535
FE457
31203
0x04B2
65535
FE458
31204
0x04B3
65535
FE459
31205
0x04B4
65535
FE460
31206
0x04B5
65535
FE461
31207
0x04B6
65535
FE462
31208
0x04B7
65535
FE463
31209
0x04B8
65535
FE464
31210
0x04B9
65535
FE465
31211
0x04BA
65535
FE466
31212
0x04BB
65535
FE467
11-24
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
Y
Y
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
31213
0x04BC
65535
FE468
Y Y Y Y
31214
65535
FE469
Y Y Y Y
31215
0x04BE
65535
FE470
Y Y Y Y
31216
0x04BF
65535
FE471
Y Y Y Y
31217
0x04C0
65535
FE472
Y Y Y Y
31218
0x04C1
65535
FE473
Y Y Y Y
31219
0x04C2
65535
FE474
Y Y Y Y
31220
0x04C3
65535
FE475
Y Y Y Y
31221
0x04C4
65535
FE476
Y Y Y Y
31222
0x04C5
65535
FE477
Y Y Y Y
31223
0x04C6
65535
FE478
Y Y Y Y
31224
0x04C7
65535
FE479
Y Y Y Y
31225
0x04C8
65535
FE480
Y Y Y Y
31226
0x04C9
65535
FE481
Y Y Y Y
31227
0x04CA
65535
FE482
Y Y Y Y
31228
0x04CB
65535
FE483
Y Y Y Y
31229
0x04CC
65535
FE484
Y Y Y Y
31230
65535
FE485
Y Y Y Y
31231
0x04CE
65535
FE486
Y Y Y Y
31232
0x04CF
65535
FE487
Y Y Y Y
31233
0x04D0
65535
FE488
Y Y Y Y
31234
0x04D1
65535
FE489
Y Y Y Y
31235
0x04D2
65535
FE490
Y Y Y Y
31236
0x04D3
65535
FE491
Y Y Y Y
31237
0x04D4
65535
FE492
Y Y Y Y
31238
0x04D5
65535
FE493
Y Y Y Y
31239
0x04D6
65535
FE494
Y Y Y Y
31240
0x04D7
65535
FE495
Y Y Y Y
31241
0x04D8
65535
FE496
Y Y Y Y
31242
0x04D9
65535
FE497
Y Y Y Y
31243
65535
FE498
Y Y Y Y
31244
65535
FE499
Y Y Y Y
31245
65535
FE500
Y Y Y Y
31246
65535
FE501
Y Y Y Y
31247
0x04DE
65535
FE502
Y Y Y Y
31248
0x04DF
65535
FE503
Y Y Y Y
31249
0x04E0
65535
FE504
Y Y Y Y
31250
0x04E1
65535
FE505
Y Y Y Y
31251
0x04E2
65535
FE506
Y Y Y Y
31252
0x04E3
65535
FE507
Y Y Y Y
31253
0x04E4
65535
FE508
Y Y Y Y
31254
0x04E5
65535
FE509
Y Y Y Y
31255
0x04E6
65535
FE510
Y Y Y Y
31256
0x04E7
65535
FE511
Y Y Y Y
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
11-25
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
31257
0x04E8
65535
FE512
31258
0x04E9
Active Group
0xFFFF
FC132
Y Y Y Y
31259
0x04EA
65535
FC118
Y Y Y Y
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
Y Y Y Y
Current Values 1
31270
0x04F5
J1 Ia
0xFFFFFFFF
F13
Y Y Y Y
31272
0x04F7
J1 Ib
0xFFFFFFFF
F13
Y Y Y Y
31274
0x04F9
J1 Ic
0xFFFFFFFF
F13
Y Y Y Y
31276
0x04FB
J1 Ig
0xFFFFFFFF
F13
Y Y Y Y
31278
0x04FD
J1 In
0xFFFFFFFF
F13
Y Y Y Y
31280
0x04FF
J1 Ia RMS
0xFFFFFFFF
F13
Y Y Y Y
31282
0x0501
J1 Ib RMS
0xFFFFFFFF
F13
Y Y Y Y
31284
0x0503
J1 Ic RMS
0xFFFFFFFF
F13
Y Y Y Y
31286
0x0505
J1 Ig RMS
0xFFFFFFFF
F13
Y Y Y Y
31288
0x0507
J1 In RMS
0xFFFFFFFF
F13
Y Y Y Y
31290
0x0509
J1 Ia Angle
-3599
F21
Y Y Y Y
31291
0x050A
J1 Ib Angle
-3599
F21
Y Y Y Y
31292
0x050B
J1 Ic Angle
-3599
F21
Y Y Y Y
31293
0x050C
J1 Ig Angle
-3599
F21
Y Y Y Y
31294
0x050D
J1 In Angle
-3599
F21
Y Y Y Y
31295
0x050E
J1 I AVG
0xFFFFFFFF
F13
Y Y Y Y
31297
0x0510
J1 I_0
0xFFFFFFFF
F13
Y Y Y Y
31299
0x0512
J1 I_1
0xFFFFFFFF
F13
Y Y Y Y
31301
0x0514
J1 I_2
0xFFFFFFFF
F13
Y Y Y Y
31303
0x0516
J1 I_0 Angle
-3599
F21
Y Y Y Y
31304
0x0517
J1 I_1 Angle
-3599
F21
Y Y Y Y
31305
0x0518
J1 I_2 Angle
-3599
F21
Y Y Y Y
31306
0x0519
J1 Igd
0xFFFFFFFF
F13
Y Y
31308
0x051B
J1 Igd Angle
-3599
F21
Y Y
31309
0x051C
J1 Load
2000
F1
Y Y Y Y
Current Values 2
31320
0x0527
K1 Ia
0xFFFFFFFF
F13
Y Y Y
31322
0x0529
K1 Ib
0xFFFFFFFF
F13
Y Y Y
31324
0x052B
K1 Ic
0xFFFFFFFF
F13
Y Y Y
31326
0x052D
K1 Ig
0xFFFFFFFF
F13
Y Y Y Y
31328
0x052F
K1 In
0xFFFFFFFF
F13
Y Y Y
31330
0x0531
K1 Ia RMS
0xFFFFFFFF
F13
Y Y Y
31332
0x0533
K1 Ib RMS
0xFFFFFFFF
F13
Y Y Y
31334
0x0535
K1 Ic RMS
0xFFFFFFFF
F13
Y Y Y
31336
0x0537
K1 Ig RMS
0xFFFFFFFF
F13
Y Y Y Y
31338
0x0539
K1 In RMS
0xFFFFFFFF
F13
Y Y Y
31340
0x053B
K1 Ia Angle
-3599
F21
Y Y Y
31341
0x053C
K1 Ib Angle
-3599
F21
Y Y Y
31342
0x053D
K1 Ic Angle
-3599
F21
Y Y Y
31343
0x053E
K1 Ig Angle
-3599
F21
Y Y Y Y
31344
0x053F
K1 In Angle
-3599
F21
Y Y Y
11-26
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
31345
0x0540
K1 I AVG
0xFFFFFFFF
F13
Y Y Y
31347
0x0542
K1 I_0
0xFFFFFFFF
F13
Y Y Y
31349
0x0544
K1 I_1
0xFFFFFFFF
F13
Y Y Y
31351
0x0546
K1 I_2
0xFFFFFFFF
F13
Y Y Y
31353
0x0548
K1 I_0 Angle
-3599
F21
Y Y Y
31354
0x0549
K1 I_1 Angle
-3599
F21
Y Y Y
31355
0x054A
K1 I_2 Angle
-3599
F21
Y Y Y
31356
0x054B
K1 Igd
0xFFFFFFFF
F13
Y Y
31358
0x054D
K1 Igd Angle
-3599
F21
Y Y
31359
0x054E
K1 Load
2000
F1
Y Y
K2 Ia
0xFFFFFFFF
F13
Y Y
Current Values 3
31370
0x0559
31372
0x055B
K2 Ib
0xFFFFFFFF
F13
Y Y
31374
0x055D
K2 Ic
0xFFFFFFFF
F13
Y Y
31376
0x055F
K2 Ig
0xFFFFFFFF
F13
Y Y
31378
0x0561
K2 In
0xFFFFFFFF
F13
Y Y
31380
0x0563
K2 Ia RMS
0xFFFFFFFF
F13
Y Y
31382
0x0565
K2 Ib RMS
0xFFFFFFFF
F13
Y Y
31384
0x0567
K2 Ic RMS
0xFFFFFFFF
F13
Y Y
31386
0x0569
K2 Ig RMS
0xFFFFFFFF
F13
Y Y
31388
0x056B
K2 In RMS
0xFFFFFFFF
F13
Y Y
31390
0x056D
K2 Ia Angle
-3599
F21
Y Y
31391
0x056E
K2 Ib Angle
-3599
F21
Y Y
31392
0x056F
K2 Ic Angle
-3599
F21
Y Y
31393
0x0570
K2 Ig Angle
-3599
F21
Y Y
31394
0x0571
K2 In Angle
-3599
F21
Y Y
31395
0x0572
K2 I AVG
0xFFFFFFFF
F13
Y Y
31397
0x0574
K2 I_0
0xFFFFFFFF
F13
Y Y
31399
0x0576
K2 I_1
0xFFFFFFFF
F13
Y Y
31401
0x0578
K2 I_2
0xFFFFFFFF
F13
Y Y
31403
0x057A
K2 I_0 Angle
-3599
F21
Y Y
31404
0x057B
K2 I_1 Angle
-3599
F21
Y Y
31405
0x057C
K2 I_2 Angle
-3599
F21
Y Y
31406
0x057D
K2 Igd
0xFFFFFFFF
F13
Y Y
31408
0x057F
K2 Igd Angle
-3599
F21
Y Y
31409
0x0580
K2 Load
2000
F1
Y Y
Voltages 1
31430
0x0595
J2 Van
200000000
F12
Y Y Y Y
31432
0x0597
J2 Vbn
200000000
F12
Y Y Y Y
31434
0x0599
J2 Vcn
200000000
F12
Y Y Y Y
31436
0x059B
J2 Vab
200000000
F12
Y Y Y Y
31438
0x059D
J2 Vbc
200000000
F12
Y Y Y Y
31440
0x059F
J2 Vca
200000000
F12
Y Y Y Y
31442
0x05A1
J2 Vn
200000000
F12
Y Y Y Y
31444
0x05A3
J2 Vaux
200000000
F12
Y Y Y Y
11-27
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
31446
0x05A5
J2 Van RMS
200000000
F12
Y Y Y Y
31448
0x05A7
J2 Vbn RMS
200000000
F12
Y Y Y Y
31450
0x05A9
J2 Vcn RMS
200000000
F12
Y Y Y Y
31452
0x05AB
J2 Vab RMS
200000000
F12
Y Y Y Y
31454
200000000
F12
Y Y Y Y
31456
0x05AF
J2 Vca RMS
200000000
F12
Y Y Y Y
31458
0x05B1
J2 Vn RMS
200000000
F12
Y Y Y Y
31460
0x05B3
J2 Vaux RMS
200000000
F12
Y Y Y Y
31462
0x05B5
J2 Van Angle
-3599
F21
Y Y Y Y
31463
0x05B6
J2 Vbn Angle
-3599
F21
Y Y Y Y
31464
0x05B7
J2 Vcn Angle
-3599
F21
Y Y Y Y
31465
0x05B8
J2 Vab Angle
-3599
F21
Y Y Y Y
31466
0x05B9
J2 Vbc Angle
-3599
F21
Y Y Y Y
31467
0x05BA
J2 Vca Angle
-3599
F21
Y Y Y Y
31468
0x05BB
J2 Vn Angle
-3599
F21
Y Y Y Y
31469
0x05BC
J2 Vaux Angle
-3599
F21
Y Y Y Y
31470
200000000
F12
Y Y Y Y
31472
0x05BF
J2 V AVG L-N
200000000
F12
Y Y Y Y
31474
0x05C1
J2 V0
200000000
F12
Y Y Y Y
31476
0x05C3
J2 V1
200000000
F12
Y Y Y Y
31478
0x05C5
J2 V2
200000000
F12
Y Y Y Y
31480
0x05C7
J2 V0 Angle
-3599
F21
Y Y Y Y
31481
0x05C8
J2 V1 Angle
-3599
F21
Y Y Y Y
31482
0x05C9
J2 V2 Angle
-3599
F21
Y Y Y Y
Voltages 2
31493
0x05D4
K2 Van
200000000
F12
31495
0x05D6
K2 Vbn
200000000
F12
31497
0x05D8
K2 Vcn
200000000
F12
31499
0x05DA K2 Vab
200000000
F12
31501
0x05DC K2 Vbc
200000000
F12
31503
0x05DE
K2 Vca
200000000
F12
31505
0x05E0
K2 Vn
200000000
F12
31507
0x05E2
K2 Vaux
200000000
F12
31509
0x05E4
K2 Van RMS
200000000
F12
31511
0x05E6
K2 Vbn RMS
200000000
F12
31513
0x05E8
K2 Vcn RMS
200000000
F12
31515
0x05EA
K2 Vab RMS
200000000
F12
31517
0x05EC
K2 Vbc RMS
200000000
F12
31519
0x05EE
K2 Vca RMS
200000000
F12
31521
0x05F0
K2 Vn RMS
200000000
F12
31523
0x05F2
K2 Vaux RMS
200000000
F12
31525
0x05F4
K2 Van Angle
-3599
F21
31526
0x05F5
K2 Vbn Angle
-3599
F21
31527
0x05F6
K2 Vcn Angle
-3599
F21
31528
0x05F7
K2 Vab Angle
-3599
F21
11-28
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
31529
0x05F8
-3599
F21
31530
0x05F9
K2 Vca Angle
-3599
F21
31531
0x05FA
K2 Vn Angle
-3599
F21
31532
0x05FB
K2 Vaux Angle
-3599
F21
31533
0x05FC
K2 V AVG L-L
200000000
F12
31535
0x05FE
K2 V AVG L-N
200000000
F12
31537
0x0600
K2 V0
200000000
F12
31539
0x0602
K2 V1
200000000
F12
31541
0x0604
K2 V2
200000000
F12
31543
0x0606
K2 V0 Angle
-3599
F21
31544
0x0607
K2 V1 Angle
-3599
F21
31545
0x0608
K2 V2 Angle
-3599
F21
Frequency
2000
90000
Hz
F13
2000
K2 Vbc Angle
Frequency Values 1
31571
0x0622
Y Y Y Y
Harmonics 1
31610
0x0649
J1 Phase A THD
65535
F1
Y Y Y Y
31611
0x064A
J1 Phase B THD
65535
F1
Y Y Y Y
31612
0x064B
J1 Phase C THD
65535
F1
Y Y Y Y
31613
0x064C
65535
F1
Y Y Y Y
31614
0x064D
65535
F1
Y Y Y Y
31615
0x064E
65535
F1
Y Y Y Y
31616
0x064F
65535
F1
Y Y Y Y
31617
0x0650
65535
F1
Y Y Y Y
31618
0x0651
65535
F1
Y Y Y Y
31619
0x0652
65535
F1
Y Y Y Y
31620
0x0653
65535
F1
Y Y Y Y
31621
0x0654
65535
F1
Y Y Y Y
31622
0x0655
65535
F1
Y Y Y Y
31623
0x0656
65535
F1
Y Y Y Y
31624
0x0657
65535
F1
Y Y Y Y
31625
0x0658
65535
F1
Y Y Y Y
31626
0x0659
65535
F1
Y Y Y Y
31627
0x065A
65535
F1
Y Y Y Y
31628
0x065B
65535
F1
Y Y Y Y
31629
0x065C
65535
F1
Y Y Y Y
31630
0x065D
65535
F1
Y Y Y Y
31631
0x065E
65535
F1
Y Y Y Y
31632
0x065F
65535
F1
Y Y Y Y
31633
0x0660
65535
F1
Y Y Y Y
31634
0x0661
65535
F1
Y Y Y Y
31635
0x0662
65535
F1
Y Y Y Y
31636
0x0663
65535
F1
Y Y Y Y
31637
0x0664
65535
F1
Y Y Y Y
31638
0x0665
65535
F1
Y Y Y Y
31639
0x0666
65535
F1
Y Y Y Y
11-29
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
31640
0x0667
65535
F1
Y Y Y Y
31641
0x0668
65535
F1
Y Y Y Y
31642
0x0669
65535
F1
Y Y Y Y
31643
0x066A
65535
F1
Y Y Y Y
31644
0x066B
65535
F1
Y Y Y Y
31645
0x066C
65535
F1
Y Y Y Y
31646
0x066D
65535
F1
Y Y Y Y
31647
0x066E
65535
F1
Y Y Y Y
31648
0x066F
65535
F1
Y Y Y Y
31649
0x0670
65535
F1
Y Y Y Y
31650
0x0671
65535
F1
Y Y Y Y
31651
0x0672
65535
F1
Y Y Y Y
31652
0x0673
65535
F1
Y Y Y Y
31653
0x0674
65535
F1
Y Y Y Y
31654
0x0675
65535
F1
Y Y Y Y
31655
0x0676
65535
F1
Y Y Y Y
31656
0x0677
65535
F1
Y Y Y Y
31657
0x0678
65535
F1
Y Y Y Y
31658
0x0679
65535
F1
Y Y Y Y
31659
0x067A
65535
F1
Y Y Y Y
31660
0x067B
65535
F1
Y Y Y Y
31661
0x067C
65535
F1
Y Y Y Y
31662
0x067D
65535
F1
Y Y Y Y
31663
0x067E
65535
F1
Y Y Y Y
31664
0x067F
65535
F1
Y Y Y Y
31665
0x0680
65535
F1
Y Y Y Y
31666
0x0681
65535
F1
Y Y Y Y
31667
0x0682
65535
F1
Y Y Y Y
31668
0x0683
65535
F1
Y Y Y Y
31669
0x0684
65535
F1
Y Y Y Y
31670
0x0685
65535
F1
Y Y Y Y
31671
0x0686
65535
F1
Y Y Y Y
31672
0x0687
65535
F1
Y Y Y Y
31673
0x0688
65535
F1
Y Y Y Y
31674
0x0689
65535
F1
Y Y Y Y
31675
0x068A
65535
F1
Y Y Y Y
31676
0x068B
65535
F1
Y Y Y Y
31677
0x068C
65535
F1
Y Y Y Y
31678
0x068D
65535
F1
Y Y Y Y
31679
0x068E
65535
F1
Y Y Y Y
31680
0x068F
65535
F1
Y Y Y Y
31681
0x0690
65535
F1
Y Y Y Y
31682
0x0691
65535
F1
Y Y Y Y
31683
0x0692
65535
F1
Y Y Y Y
31684
0x0693
65535
F1
Y Y Y Y
11-30
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
Harmonics 2
31695
0x069E
J2 Phase A THD
65535
F1
Y Y Y Y
31696
0x069F
J2 Phase B THD
65535
F1
Y Y Y Y
31697
0x06A0
J2 Phase C THD
65535
F1
Y Y Y Y
31698
0x06A1
65535
F1
Y Y Y Y
31699
0x06A2
65535
F1
Y Y Y Y
31700
0x06A3
65535
F1
Y Y Y Y
31701
0x06A4
65535
F1
Y Y Y Y
31702
0x06A5
65535
F1
Y Y Y Y
31703
0x06A6
65535
F1
Y Y Y Y
31704
0x06A7
65535
F1
Y Y Y Y
31705
0x06A8
65535
F1
Y Y Y Y
31706
0x06A9
65535
F1
Y Y Y Y
31707
0x06AA
65535
F1
Y Y Y Y
31708
0x06AB
65535
F1
Y Y Y Y
31709
0x06AC
65535
F1
Y Y Y Y
31710
65535
F1
Y Y Y Y
31711
0x06AE
65535
F1
Y Y Y Y
31712
0x06AF
65535
F1
Y Y Y Y
31713
0x06B0
65535
F1
Y Y Y Y
31714
0x06B1
65535
F1
Y Y Y Y
31715
0x06B2
65535
F1
Y Y Y Y
31716
0x06B3
65535
F1
Y Y Y Y
31717
0x06B4
65535
F1
Y Y Y Y
31718
0x06B5
65535
F1
Y Y Y Y
31719
0x06B6
65535
F1
Y Y Y Y
31720
0x06B7
65535
F1
Y Y Y Y
31721
0x06B8
65535
F1
Y Y Y Y
31722
0x06B9
65535
F1
Y Y Y Y
31723
0x06BA
65535
F1
Y Y Y Y
31724
0x06BB
65535
F1
Y Y Y Y
31725
0x06BC
65535
F1
Y Y Y Y
31726
65535
F1
Y Y Y Y
31727
0x06BE
65535
F1
Y Y Y Y
31728
0x06BF
65535
F1
Y Y Y Y
31729
0x06C0
65535
F1
Y Y Y Y
31730
0x06C1
65535
F1
Y Y Y Y
31731
0x06C2
65535
F1
Y Y Y Y
31732
0x06C3
65535
F1
Y Y Y Y
31733
0x06C4
65535
F1
Y Y Y Y
31734
0x06C5
65535
F1
Y Y Y Y
31735
0x06C6
65535
F1
Y Y Y Y
31736
0x06C7
65535
F1
Y Y Y Y
31737
0x06C8
65535
F1
Y Y Y Y
31738
0x06C9
65535
F1
Y Y Y Y
11-31
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
31739
65535
F1
0x06CA
Y Y Y Y
31740
0x06CB
65535
F1
Y Y Y Y
31741
0x06CC
65535
F1
Y Y Y Y
31742
65535
F1
Y Y Y Y
31743
0x06CE
65535
F1
Y Y Y Y
31744
0x06CF
65535
F1
Y Y Y Y
31745
0x06D0
65535
F1
Y Y Y Y
31746
0x06D1
65535
F1
Y Y Y Y
31747
0x06D2
65535
F1
Y Y Y Y
31748
0x06D3
65535
F1
Y Y Y Y
31749
0x06D4
65535
F1
Y Y Y Y
31750
0x06D5
65535
F1
Y Y Y Y
31751
0x06D6
65535
F1
Y Y Y Y
31752
0x06D7
65535
F1
Y Y Y Y
31753
0x06D8
65535
F1
Y Y Y Y
31754
0x06D9
65535
F1
Y Y Y Y
31755
65535
F1
Y Y Y Y
31756
65535
F1
Y Y Y Y
31757
65535
F1
Y Y Y Y
31758
65535
F1
Y Y Y Y
31759
0x06DE
65535
F1
Y Y Y Y
31760
0x06DF
65535
F1
Y Y Y Y
31761
0x06E0
65535
F1
Y Y Y Y
31762
0x06E1
65535
F1
Y Y Y Y
31763
0x06E2
65535
F1
Y Y Y Y
31764
0x06E3
65535
F1
Y Y Y Y
31765
0x06E4
65535
F1
Y Y Y Y
31766
0x06E5
65535
F1
Y Y Y Y
31767
0x06E6
65535
F1
Y Y Y Y
31768
0x06E7
65535
F1
Y Y Y Y
31769
0x06E8
65535
F1
Y Y Y Y
K1 Phase A THD
65535
F1
Y Y
Harmonics 3
31780
0x06F3
31781
0x06F4
K1 Phase B THD
65535
F1
Y Y
31782
0x06F5
K1 Phase C THD
65535
F1
Y Y
31783
0x06F6
65535
F1
Y Y
31784
0x06F7
65535
F1
Y Y
31785
0x06F8
65535
F1
Y Y
31786
0x06F9
65535
F1
Y Y
31787
0x06FA
65535
F1
Y Y
31788
0x06FB
65535
F1
Y Y
31789
0x06FC
65535
F1
Y Y
31790
0x06FD
65535
F1
Y Y
31791
0x06FE
65535
F1
Y Y
31792
0x06FF
65535
F1
Y Y
11-32
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
31793
0x0700
65535
F1
31794
0x0701
65535
F1
Y Y
31795
0x0702
65535
F1
Y Y
31796
0x0703
65535
F1
Y Y
31797
0x0704
65535
F1
Y Y
31798
0x0705
65535
F1
Y Y
Y Y
31799
0x0706
65535
F1
Y Y
31800
0x0707
65535
F1
Y Y
31801
0x0708
65535
F1
Y Y
31802
0x0709
65535
F1
Y Y
31803
0x070A
65535
F1
Y Y
31804
0x070B
65535
F1
Y Y
31805
0x070C
65535
F1
Y Y
31806
0x070D
65535
F1
Y Y
31807
0x070E
65535
F1
Y Y
31808
0x070F
65535
F1
Y Y
31809
0x0710
65535
F1
Y Y
31810
0x0711
65535
F1
Y Y
31811
0x0712
65535
F1
Y Y
31812
0x0713
65535
F1
Y Y
31813
0x0714
65535
F1
Y Y
31814
0x0715
65535
F1
Y Y
31815
0x0716
65535
F1
Y Y
31816
0x0717
65535
F1
Y Y
31817
0x0718
65535
F1
Y Y
31818
0x0719
65535
F1
Y Y
31819
0x071A
65535
F1
Y Y
31820
0x071B
65535
F1
Y Y
31821
0x071C
65535
F1
Y Y
31822
0x071D
65535
F1
Y Y
31823
0x071E
65535
F1
Y Y
31824
0x071F
65535
F1
Y Y
31825
0x0720
65535
F1
Y Y
31826
0x0721
65535
F1
Y Y
31827
0x0722
65535
F1
Y Y
31828
0x0723
65535
F1
Y Y
31829
0x0724
65535
F1
Y Y
31830
0x0725
65535
F1
Y Y
31831
0x0726
65535
F1
Y Y
31832
0x0727
65535
F1
Y Y
31833
0x0728
65535
F1
Y Y
31834
0x0729
65535
F1
Y Y
31835
0x072A
65535
F1
Y Y
31836
0x072B
65535
F1
Y Y
31837
0x072C
65535
F1
Y Y
11-33
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
31838
0x072D
65535
F1
Y Y
31839
0x072E
65535
F1
Y Y
31840
0x072F
65535
F1
Y Y
31841
0x0730
65535
F1
Y Y
31842
0x0731
65535
F1
Y Y
31843
0x0732
65535
F1
Y Y
31844
0x0733
65535
F1
Y Y
31845
0x0734
65535
F1
Y Y
31846
0x0735
65535
F1
Y Y
31847
0x0736
65535
F1
Y Y
31848
0x0737
65535
F1
Y Y
31849
0x0738
65535
F1
Y Y
31850
0x0739
65535
F1
Y Y
31851
0x073A
65535
F1
Y Y
31852
0x073B
65535
F1
Y Y
31853
0x073C
65535
F1
Y Y
31854
0x073D
65535
F1
Y Y
Harmonics 4
31865
0x0748
K2 Phase A THD
65535
F1
Y Y
31866
0x0749
K2 Phase B THD
65535
F1
Y Y
31867
0x074A
K2 Phase C THD
65535
F1
Y Y
31868
0x074B
65535
F1
Y Y
31869
0x074C
65535
F1
Y Y
31870
0x074D
65535
F1
Y Y
31871
0x074E
65535
F1
Y Y
31872
0x074F
65535
F1
Y Y
31873
0x0750
65535
F1
Y Y
31874
0x0751
65535
F1
Y Y
31875
0x0752
65535
F1
Y Y
31876
0x0753
65535
F1
Y Y
31877
0x0754
65535
F1
Y Y
31878
0x0755
65535
F1
Y Y
31879
0x0756
65535
F1
Y Y
31880
0x0757
65535
F1
Y Y
31881
0x0758
65535
F1
Y Y
31882
0x0759
65535
F1
Y Y
31883
0x075A
65535
F1
Y Y
31884
0x075B
65535
F1
Y Y
31885
0x075C
65535
F1
Y Y
31886
0x075D
65535
F1
Y Y
31887
0x075E
65535
F1
Y Y
31888
0x075F
65535
F1
Y Y
31889
0x0760
65535
F1
Y Y
31890
0x0761
65535
F1
Y Y
31891
0x0762
65535
F1
Y Y
11-34
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
31892
65535
F1
0x0763
Y Y
31893
0x0764
65535
F1
Y Y
31894
0x0765
65535
F1
Y Y
31895
0x0766
65535
F1
Y Y
31896
0x0767
65535
F1
Y Y
31897
0x0768
65535
F1
Y Y
31898
0x0769
65535
F1
Y Y
31899
0x076A
65535
F1
Y Y
31900
0x076B
65535
F1
Y Y
31901
0x076C
65535
F1
Y Y
31902
0x076D
65535
F1
Y Y
31903
0x076E
65535
F1
Y Y
31904
0x076F
65535
F1
Y Y
31905
0x0770
65535
F1
Y Y
31906
0x0771
65535
F1
Y Y
31907
0x0772
65535
F1
Y Y
31908
0x0773
65535
F1
Y Y
31909
0x0774
65535
F1
Y Y
31910
0x0775
65535
F1
Y Y
31911
0x0776
65535
F1
Y Y
31912
0x0777
65535
F1
Y Y
31913
0x0778
65535
F1
Y Y
31914
0x0779
65535
F1
Y Y
31915
0x077A
65535
F1
Y Y
31916
0x077B
65535
F1
Y Y
31917
0x077C
65535
F1
Y Y
31918
0x077D
65535
F1
Y Y
31919
0x077E
65535
F1
Y Y
31920
0x077F
65535
F1
Y Y
31921
0x0780
65535
F1
Y Y
31922
0x0781
65535
F1
Y Y
31923
0x0782
65535
F1
Y Y
31924
0x0783
65535
F1
Y Y
31925
0x0784
65535
F1
Y Y
31926
0x0785
65535
F1
Y Y
31927
0x0786
65535
F1
Y Y
31928
0x0787
65535
F1
Y Y
31929
0x0788
65535
F1
Y Y
31930
0x0789
65535
F1
Y Y
31931
0x078A
65535
F1
Y Y
31932
0x078B
65535
F1
Y Y
31933
0x078C
65535
F1
Y Y
31934
0x078D
65535
F1
Y Y
31935
0x078E
65535
F1
Y Y
31936
0x078F
65535
F1
Y Y
11-35
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
31937
65535
F1
0x0790
Y Y
31938
0x0791
65535
F1
Y Y
31939
0x0792
65535
F1
Y Y
Synchrocheck 1 Metering
31960
0x07A7
200000000
F12
Y Y
31962
0x07A9
-3599
F21
Y Y
31963
0x07AA
120000
Hz
F13
Y Y
31965
0x07AC
200000000
F12
Y Y
31967
0x07AE
-3599
F21
Y Y
31968
0x07AF
120000
Hz
F13
10
Y Y
31970
0x07B1
Voltage Difference
0xFFFFFFFF
F12
Y Y
31972
0x07B3
Angle Difference
180
F1
Y Y
31973
0x07B4
Frequency Difference
120000
Hz
F13
10
Y Y
Power Values 1
32020
0x07E3
Pwr1 Real
-2147483648 2147483647
kW
F31
Y Y Y Y
32022
0x07E5
Pwr1 Reactive
-2147483648 2147483647
kvar
F31
Y Y Y Y
32024
0x07E7
Pwr1 Apparent
-2147483648 2147483647
kVA
F31
Y Y Y Y
32026
0x07E9
Pwr1 Ph A Real
-2147483648 2147483647
kW
F31
Y Y Y Y
32028
0x07EB
Pwr1 Ph B Real
-2147483648 2147483647
kW
F31
Y Y Y Y
32030
0x07ED
Pwr1 Ph C Real
-2147483648 2147483647
kW
F31
Y Y Y Y
32032
0x07EF
Pwr1 Ph A Reactive
-2147483648 2147483647
kvar
F31
Y Y Y Y
32034
0x07F1
Pwr1 Ph B Reactive
-2147483648 2147483647
kvar
F31
Y Y Y Y
32036
0x07F3
Pwr1 Ph C Reactive
-2147483648 2147483647
kvar
F31
Y Y Y Y
32038
0x07F5
Pwr1 Ph A Apparent
-2147483648 2147483647
kVA
F31
Y Y Y Y
32040
0x07F7
Pwr1 Ph B Apparent
-2147483648 2147483647
kVA
F31
Y Y Y Y
32042
0x07F9
Pwr1 Ph C Apparent
-2147483648 2147483647
kVA
F31
Y Y Y Y
32044
0x07FB
Pwr1 PF
-99
100
F22
Y Y Y Y
32045
0x07FC
Pwr1 Ph A PF
-99
100
F22
Y Y Y Y
32046
0x07FD
Pwr1 Ph B PF
-99
100
F22
Y Y Y Y
32047
0x07FE
Pwr1 Ph C PF
-99
100
F22
Y Y Y Y
F50
Y Y Y Y
F51
Y Y Y Y
Energy Values 1
32110
0x083D
0xFFFFFFFF
32112
0x083F
999999
us
32114
0x0841
4294967295
MWh
F13
Y Y Y Y
32116
0x0843
0xFFFFFFFF
F12
32118
0x0845
4294967295
MWh
F13
Y Y Y Y
32120
0x0847
0xFFFFFFFF
F12
32122
0x0849
4294967295
Mvarh
F13
Y Y Y Y
32124
0x084B
4294967295
Mvarh
F13
Y Y Y Y
Power Factor
32170
0x0879
Power Factor 1
-99
100
F22
Y Y Y Y
32171
0x087A
Power Factor 2
-99
100
F22
Y Y Y Y
0xFFFFFFFF
F50
Y Y Y Y
11-36
0x0883
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
32182
0x0885
999999
us
F51
Y Y Y Y
32184
0x0887
Cur1 Ph A Demand
0xFFFFFFFF
F13
Y Y Y Y
32186
0x0889
Cur1 Ph B Demand
0xFFFFFFFF
F13
Y Y Y Y
32188
0x088B
Cur1 Ph C Demand
0xFFFFFFFF
F13
Y Y Y Y
32190
0x088D
0xFFFFFFFF
F13
Y Y Y Y
32192
0x088F
0xFFFFFFFF
F13
Y Y Y Y
32194
0x0891
0xFFFFFFFF
F13
Y Y Y Y
32196
0x0893
0xFFFFFFFF
F50
Y Y Y Y
32198
0x0895
0xFFFFFFFF
F50
Y Y Y Y
32200
0x0897
0xFFFFFFFF
F50
Y Y Y Y
32202
0x0899
999999
us
F51
Y Y Y Y
32204
0x089B
999999
us
F51
Y Y Y Y
32206
0x089D
999999
us
F51
Y Y Y Y
0x08A9
32220
0x08AB
0xFFFFFFFF
F50
999999
us
F51
32222
32224
0x08AF
Cur2 Ph B Demand
0xFFFFFFFF
F13
0xFFFFFFFF
F13
32226
0x08B1
32228
0x08B3
Cur2 Ph C Demand
0xFFFFFFFF
F13
0xFFFFFFFF
F13
32230
0x08B5
0xFFFFFFFF
F13
32232
0x08B7
0xFFFFFFFF
32234
0x08B9
0xFFFFFFFF
F13
F50
32236
0x08BB
0xFFFFFFFF
F50
32238
0xFFFFFFFF
F50
32240
0x08BF
999999
us
F51
32242
0x08C1
999999
us
F51
32244
0x08C3
999999
us
F51
0xFFFFFFFF
F50
0x08CF
32258
0x08D1
999999
us
F51
32260
0x08D3
Cur3 Ph A Demand
0xFFFFFFFF
F13
32262
0x08D5
Cur3 Ph B Demand
0xFFFFFFFF
F13
32264
0x08D7
Cur3 Ph C Demand
0xFFFFFFFF
F13
32266
0x08D9
0xFFFFFFFF
F13
32268
0xFFFFFFFF
F13
32270
0xFFFFFFFF
F13
32272
0x08DF
0xFFFFFFFF
F50
32274
0x08E1
0xFFFFFFFF
F50
32276
0x08E3
0xFFFFFFFF
F50
11-37
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
32278
0x08E5
999999
us
F51
32280
0x08E7
999999
us
F51
32282
0x08E9
999999
us
F51
0xFFFFFFFF
F50
Y Y Y Y
999999
0x0905
32312
0x0907
us
F51
Y Y Y Y
32314
0x0909
-2147483648 2147483647
kW
F31
Y Y Y Y
32316
0x090B
-2147483648 2147483647
kW
F31
Y Y Y Y
32318
0x090D
0xFFFFFFFF
F50
Y Y Y Y
32320
0x090F
999999
F51
Y Y Y Y
32322
0x0911
-2147483648 2147483647
kvar
F31
Y Y Y Y
32324
0x0913
-2147483648 2147483647
kvar
F31
Y Y Y Y
32326
0x0915
0xFFFFFFFF
F50
Y Y Y Y
32328
0x0917
999999
us
F51
Y Y Y Y
32330
0x0919
-2147483648 2147483647
kVA
F31
Y Y Y Y
kVA
32332
0x091B
32334
0x091D
0xFFFFFFFF
32336
0x091F
999999
65535
us
F31
Y Y Y Y
F50
Y Y Y Y
us
F51
Y Y Y Y
shots
F0
AutoReclose 1 Status
32580
0x0A13
32581
0x0A14
Shots Remaining
65535
shots
F0
32582
0x0A15
65535
sh/hr
F0
shots
32583
0x0A16
65535
32584
0x0A17
0xFFFFFFFF
32586
0x0A19
999999
us
F0
F50
F51
Arcing Current
32620
0x0A3B
0xFFFFFFFF
kA2-cyc F10
Y Y Y Y
32622
0xFFFFFFFF
kA2-cyc F10
Y Y Y Y
32624
0x0A3F
0xFFFFFFFF
kA2-cyc F10
Y Y Y Y
Counters
32640
0x0A4F
Breaker
0xFFFFFFFF
F10
Y Y Y
32642
0x0A51
Ground
0xFFFFFFFF
F10
Y Y Y
32644
0x0A53
Sensitive Ground
65535
F0
Y Y Y
32645
0x0A54
Neutral
65535
F0
Y Y Y
32646
0x0A55
Negative Sequence
65535
F0
Y Y Y
32647
0x0A56
J1 Phase A
65535
F0
Y Y Y
32648
0x0A57
J1 Phase B
65535
F0
Y Y Y
32649
0x0A58
J1 Phase C
65535
F0
Y Y Y
32650
0x0A59
Reset Date/Time
0xFFFFFFFF
F50
Y Y Y
32652
0x0A5B
999999
F51
Y Y Y
11-38
us
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
0x0A81
Number of Reports
65535
F0
Y Y Y Y
32691
0x0A82
0xFFFFFFFF
F50
Y Y Y Y
32693
0x0A84
0xFFFFFFFF
F50
Y Y Y Y
32695
0x0A86
0xFFFFFFFF
F50
Y Y Y Y
32697
0x0A88
0xFFFFFFFF
F50
Y Y Y Y
32699
0x0A8A
0xFFFFFFFF
F50
Y Y Y Y
32701
0x0A8C
0xFFFFFFFF
F50
Y Y Y Y
32703
0x0A8E
0xFFFFFFFF
F50
Y Y Y Y
32705
0x0A90
0xFFFFFFFF
F50
Y Y Y Y
32707
0x0A92
0xFFFFFFFF
F50
Y Y Y Y
32709
0x0A94
0xFFFFFFFF
F50
Y Y Y Y
32711
0x0A96
0xFFFFFFFF
F50
Y Y Y Y
32713
0x0A98
0xFFFFFFFF
F50
Y Y Y Y
32715
0x0A9A
0xFFFFFFFF
F50
Y Y Y Y
32717
0x0A9C
0xFFFFFFFF
F50
Y Y Y Y
32719
0x0A9E
0xFFFFFFFF
F50
Y Y Y Y
F50
Y Y Y Y
F51
Y Y Y Y
F50
Y Y Y Y
F51
Y Y Y Y
Fault Report
32740
0x0AB3
0xFFFFFFFF
32742
0x0AB5
Time (us)
999999
32744
0x0AB7
0xFFFFFFFF
32746
0x0AB9
Time (us)
999999
32748
10
FC270
32749
9999
F2
32750
9999
F2
16
F0
Y Y Y Y
F50
Y Y Y Y
F51
Y Y Y Y
F50
Y Y Y Y
F51
Y Y Y Y
F50
Y Y Y Y
us
us
0x0AC7
0xFFFFFFFF
32782
999999
32786
0x0AE1
Oscill. Record 2
0xFFFFFFFF
32788
0x0AE3
999999
32792
0x0AE7
Oscill. Record 3
0xFFFFFFFF
32794
0x0AE9
999999
32798
0xFFFFFFFF
32800
0x0AEF
999999
32804
0x0AF3
Oscill. Record 5
0xFFFFFFFF
32806
0x0AF5
999999
32810
0x0AF9
Oscill. Record 6
0xFFFFFFFF
32812
0x0AFB
999999
32816
0x0AFF
Oscill. Record 7
0xFFFFFFFF
32818
0x0B01
999999
32822
0x0B05
Oscill. Record 8
0xFFFFFFFF
32824
0x0B07
999999
32828
0x0B0B
Oscill. Record 9
0xFFFFFFFF
us
us
us
us
us
us
us
us
F51
Y Y Y Y
F50
Y Y Y Y
F51
Y Y Y Y
F50
Y Y Y Y
F51
Y Y Y Y
F50
Y Y Y Y
F51
Y Y Y Y
F50
Y Y Y Y
F51
Y Y Y Y
F50
Y Y Y Y
F51
Y Y Y Y
F50
Y Y Y Y
11-39
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
32830
999999
F51
Y Y Y Y
32834
0x0B11
Oscill. Record 10
0xFFFFFFFF
F50
Y Y Y Y
32836
0x0B13
999999
F51
Y Y Y Y
32840
0x0B17
Oscill. Record 11
0xFFFFFFFF
F50
Y Y Y Y
32842
0x0B19
32846
999999
0xFFFFFFFF
32848
0x0B1F
999999
32852
0x0B23
Oscill. Record 13
0xFFFFFFFF
32854
0x0B25
999999
32858
0x0B29
Oscill. Record 14
0xFFFFFFFF
32860
0x0B2B
999999
32864
0x0B2F
Oscill. Record 15
0xFFFFFFFF
32866
0x0B31
999999
32870
0x0B35
Oscill. Record 16
0xFFFFFFFF
32872
0x0B37
999999
100000
us
us
us
us
us
us
us
us
F51
Y Y Y Y
F50
Y Y Y Y
F51
Y Y Y Y
F50
Y Y Y Y
F51
Y Y Y Y
F50
Y Y Y Y
F51
Y Y Y Y
F50
Y Y Y Y
F51
Y Y Y Y
F50
Y Y Y Y
F51
Y Y Y Y
F10
Y Y Y Y
Breaker 1 Health AV
32900
0x0B53
32902
0x0B55
100000
F10
Y Y Y Y
32904
0x0B57
Alarm Counter
100
F0
Y Y Y Y
32905
0x0B58
4294967295
F10
Y Y Y Y
32907
0x0B5A
4294967295
ms
F10
Y Y Y Y
32909
0x0B5C
4294967295
ms
F10
Y Y Y Y
ms
32911
0x0B5E
4294967295
ms
F10
Y Y Y Y
32913
0x0B60
4294967295
ms
F10
Y Y Y Y
32915
0x0B62
4294967295
ms
F10
Y Y Y Y
32917
0x0B64
4294967295
ms
F10
Y Y Y Y
32919
0x0B66
4294967295
ms
F10
Y Y Y Y
32921
0x0B68
4294967295
ms
F10
Y Y Y Y
32923
0x0B6A
4294967295
ms
F10
Y Y Y Y
32925
0x0B6C
4294967295
ms
F10
Y Y Y Y
32927
0x0B6E
4294967295
ms
F10
Y Y Y Y
32929
0x0B70
4294967295
ms
F10
Y Y Y Y
32931
0x0B72
4294967295
ms
F10
Y Y Y Y
32933
0x0B74
4294967295
ms
F10
Y Y Y Y
32935
0x0B76
6000000
F13
Y Y Y Y
32937
0x0B78
6000000
F13
Y Y Y Y
32939
0x0B7A
6000000
F13
Y Y Y Y
32941
0x0B7C
4294967295
kA2-cyc F12
Y Y Y Y
32943
0x0B7E
4294967295
kA2-cyc F12
Y Y Y Y
32945
0x0B80
4294967295
kA2-cyc F12
Y Y Y Y
32947
0x0B82
4294967295
kA2-cyc F12
Y Y Y Y
32949
0x0B84
4294967295
kA2-cyc F12
Y Y Y Y
32951
0x0B86
4294967295
kA2-cyc F12
Y Y Y Y
32953
0x0B88
4294967295
kA2-cyc F12
Y Y Y Y
32955
0x0B8A
4294967295
kA2-cyc F12
Y Y Y Y
11-40
Modbus Hex
Description
Address Address
Min
Max
Step Units
32957
4294967295
0x0B8C
Format
Code
kA2-cyc F12
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
Y Y Y Y
Breaker 2 Health AV
32963
0x0B92
100000
F10
Y Y
32965
0x0B94
100000
F10
Y Y
32967
0x0B96
Alarm Counter
100
F0
Y Y
32968
0x0B97
4294967295
F10
Y Y
32970
0x0B99
4294967295
ms
F10
Y Y
32972
0x0B9B
4294967295
ms
F10
Y Y
32974
4294967295
ms
F10
Y Y
32976
0x0B9F
4294967295
ms
F10
Y Y
32978
0x0BA1
4294967295
ms
F10
Y Y
32980
0x0BA3
4294967295
ms
F10
Y Y
32982
0x0BA5
4294967295
ms
F10
Y Y
32984
0x0BA7
4294967295
ms
F10
Y Y
32986
0x0BA9
4294967295
ms
F10
Y Y
32988
4294967295
ms
F10
Y Y
32990
4294967295
ms
F10
Y Y
ms
32992
0x0BAF
4294967295
ms
F10
Y Y
32994
0x0BB1
4294967295
ms
F10
Y Y
32996
0x0BB3
4294967295
ms
F10
Y Y
32998
0x0BB5
6000000
F13
Y Y
33000
0x0BB7
6000000
F13
Y Y
33002
0x0BB9
6000000
F13
Y Y
33004
0x0BBB
4294967295
kA2-cyc F12
Y Y
33006
4294967295
kA2-cyc F12
Y Y
33008
0x0BBF
4294967295
kA2-cyc F12
Y Y
33010
0x0BC1
4294967295
kA2-cyc F12
Y Y
33012
0x0BC3
4294967295
kA2-cyc F12
Y Y
33014
0x0BC5
4294967295
kA2-cyc F12
Y Y
33016
0x0BC7
4294967295
kA2-cyc F12
Y Y
33018
0x0BC9
4294967295
kA2-cyc F12
Y Y
33020
4294967295
kA2-cyc F12
Y Y
Breaker 3 Health AV
33026
100000
F10
33028
100000
F10
33030
100
F0
33031
4294967295
ms
F10
33033
4294967295
ms
F10
33035
4294967295
ms
F10
33037
4294967295
ms
F10
33039
4294967295
ms
F10
33041
0x0BE0
4294967295
ms
F10
33043
0x0BE2
4294967295
ms
F10
33045
0x0BE4
4294967295
ms
F10
33047
0x0BE6
4294967295
ms
F10
11-41
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
33049
0x0BE8
4294967295
ms
F10
33051
0x0BEA
4294967295
ms
F10
33053
0x0BEC
4294967295
ms
F10
33055
0x0BEE
4294967295
ms
F10
33057
0x0BF0
4294967295
ms
F10
33059
0x0BF2
4294967295
ms
F10
33061
0x0BF4
6000000
F13
33063
0x0BF6
6000000
F13
33065
0x0BF8
6000000
F13
33067
0x0BFA
4294967295
kA2-cyc F12
33069
0x0BFC
4294967295
kA2-cyc F12
33071
0x0BFE
4294967295
kA2-cyc F12
33073
0x0C00
4294967295
kA2-cyc F12
33075
0x0C02
4294967295
kA2-cyc F12
33077
0x0C04
4294967295
kA2-cyc F12
33079
0x0C06
4294967295
kA2-cyc F12
33081
0x0C08
4294967295
kA2-cyc F12
33083
0x0C0A
4294967295
kA2-cyc F12
4294967295
kA2-cyc F12
Y Y Y Y
0x0C1B
33102
4294967295
kA2-cyc F12
Y Y Y Y
33104
0x0C1F
4294967295
kA2-cyc F12
Y Y Y Y
33106
0x0C21
4294967295
kA2-cyc F12
Y Y Y Y
4294967295
kA2-cyc F12
Y Y
0x0C23
33110
0x0C25
4294967295
kA2-cyc F12
Y Y
33112
0x0C27
4294967295
kA2-cyc F12
Y Y
33114
0x0C29
4294967295
kA2-cyc F12
Y Y
4294967295
kA2-cyc F12
0x0C2B
33118
4294967295
kA2-cyc F12
33120
0x0C2F
4294967295
kA2-cyc F12
33122
0x0C31
4294967295
kA2-cyc F12
0x0C43
Counter 1 Accumulated
-2147483648 2147483647
UserF30
Defined
@
Modbus
81374
Y Y Y Y
33142
0x0C45
Counter 1 Frozen
-2147483648 2147483647
UserF30
Defined
@
Modbus
81374
Y Y Y Y
33144
0x0C47
Date/Time - Frozen
0xFFFFFFFF
F50
Y Y Y Y
33146
0x0C49
Counter 1 us - Frozen
999999
F51
Y Y Y Y
us
11-42
Modbus Hex
Description
Address Address
Min
Max
Step Units
33152
0x0C4F
Counter 2 Accumulated
-2147483648 2147483647
33154
0x0C51
Counter 2 Frozen
-2147483648 2147483647
33156
0x0C53
Date/Time - Frozen
0xFFFFFFFF
33158
0x0C55
Counter 2 us - Frozen
999999
us
-2147483648 2147483647
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
UserF30
Defined
@
Modbus
81416
Y Y Y Y
UserF30
Defined
@
Modbus
81416
Y Y Y Y
F50
Y Y Y Y
F51
Y Y Y Y
UserF30
Defined
@
Modbus
81458
Y Y Y Y
UserF30
Defined
@
Modbus
81458
Y Y Y Y
F50
0x0C5B
Counter 3 Accumulated
33166
-2147483648 2147483647
33168
0x0C5F
Date/Time - Frozen
0xFFFFFFFF
Y Y Y Y
33170
0x0C61
Counter 3 us - Frozen
999999
us
F51
Y Y Y Y
0x0C67
Counter 4 Accumulated
-2147483648 2147483647
UserF30
Defined
@
Modbus
81500
Y Y Y Y
33178
0x0C69
Counter 4 Frozen
-2147483648 2147483647
UserF30
Defined
@
Modbus
81500
Y Y Y Y
33180
0x0C6B
Date/Time - Frozen
0xFFFFFFFF
F50
Y Y Y Y
33182
999999
us
F51
Y Y Y Y
0x0C73
Counter 5 Accumulated
-2147483648 2147483647
UserF30
Defined
@
Modbus
81542
Y Y Y Y
33190
0x0C75
Counter 5 Frozen
-2147483648 2147483647
UserF30
Defined
@
Modbus
81542
Y Y Y Y
33192
0x0C77
Date/Time - Frozen
0xFFFFFFFF
F50
Y Y Y Y
33194
0x0C79
Counter 5 us - Frozen
999999
us
F51
Y Y Y Y
F30
UserDefined
@
Modbus
81584
Y Y Y Y
0x0C7F
Counter 6 Accumulated
-2147483648 2147483647
11-43
Modbus Hex
Description
Address Address
Min
Max
Step Units
33202
0x0C81
Counter 6 Frozen
-2147483648 2147483647
33204
0x0C83
Date/Time - Frozen
0xFFFFFFFF
33206
0x0C85
Counter 6 us - Frozen
999999
us
-2147483648 2147483647
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
UserF30
Defined
@
Modbus
81584
Y Y Y Y
F50
Y Y Y Y
F51
Y Y Y Y
UserF30
Defined
@
Modbus
81626
Y Y Y Y
UserF30
Defined
@
Modbus
81626
Y Y Y Y
F50
0x0C8B
Counter 7 Accumulated
33214
-2147483648 2147483647
33216
0x0C8F
Date/Time - Frozen
0xFFFFFFFF
Y Y Y Y
33218
0x0C91
Counter 7 us - Frozen
999999
us
F51
Y Y Y Y
0x0C97
Counter 8 Accumulated
-2147483648 2147483647
UserF30
Defined
@
Modbus
81668
Y Y Y Y
33226
0x0C99
Counter 8 Frozen
-2147483648 2147483647
UserF30
Defined
@
Modbus
81668
Y Y Y Y
33228
0x0C9B
Date/Time - Frozen
0xFFFFFFFF
F50
Y Y Y Y
33230
999999
us
F51
Y Y Y Y
0x0CA3
Counter 9 Accumulated
-2147483648 2147483647
UserF30
Defined
@
Modbus
81710
Y Y Y Y
33238
0x0CA5
Counter 9 Frozen
-2147483648 2147483647
UserF30
Defined
@
Modbus
81710
Y Y Y Y
33240
0x0CA7
Date/Time - Frozen
0xFFFFFFFF
F50
Y Y Y Y
33242
0x0CA9
Counter 9 us - Frozen
999999
us
F51
Y Y Y Y
0x0CAF
UserF30
Defined
@
Modbus
81752
Y Y Y Y
33250
0x0CB1
Counter 10 Frozen
-2147483648 2147483647
F30
UserDefined
@
Modbus
81752
Y Y Y Y
33252
0x0CB3
Date/Time - Frozen
0xFFFFFFFF
F50
Y Y Y Y
33254
0x0CB5
Counter 10 us - Frozen
999999
F51
Y Y Y Y
11-44
us
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
UserF30
Defined
@
Modbus
81794
Y Y Y Y
33262
-2147483648 2147483647
UserF30
Defined
@
Modbus
81794
Y Y Y Y
33264
0x0CBF
Date/Time - Frozen
0xFFFFFFFF
F50
Y Y Y Y
33266
0x0CC1
Counter 11 us - Frozen
999999
us
F51
Y Y Y Y
0x0CC7
UserF30
Defined
@
Modbus
81836
Y Y Y Y
33274
0x0CC9
Counter 12 Frozen
-2147483648 2147483647
UserF30
Defined
@
Modbus
81836
Y Y Y Y
33276
0xFFFFFFFF
F50
Y Y Y Y
33278
999999
us
F51
Y Y Y Y
UserF30
Defined
@
Modbus
81878
Y Y Y Y
33286
-2147483648 2147483647
UserF30
Defined
@
Modbus
81878
Y Y Y Y
33288
0xFFFFFFFF
F50
Y Y Y Y
33290
999999
us
F51
Y Y Y Y
UserF30
Defined
@
Modbus
81920
Y Y Y Y
33298
0x0CE1
Counter 14 Frozen
-2147483648 2147483647
UserF30
Defined
@
Modbus
81920
Y Y Y Y
33300
0x0CE3
Date/Time - Frozen
0xFFFFFFFF
F50
Y Y Y Y
33302
0x0CE5
Counter 14 us - Frozen
999999
us
F51
Y Y Y Y
F30
UserDefined
@
Modbus
81962
Y Y Y Y
0x0CEB
11-45
Modbus Hex
Description
Address Address
Min
Max
Step Units
33310
-2147483648 2147483647
33312
0x0CEF
Date/Time - Frozen
0xFFFFFFFF
33314
0x0CF1
Counter 15 us - Frozen
999999
us
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
UserF30
Defined
@
Modbus
81962
Y Y Y Y
F50
Y Y Y Y
F51
Y Y Y Y
0x0CF7
UserF30
Defined
@
Modbus
82004
Y Y Y Y
33322
0x0CF9
Counter 16 Frozen
-2147483648 2147483647
UserF30
Defined
@
Modbus
82004
Y Y Y Y
33324
0x0CFB
Date/Time - Frozen
0xFFFFFFFF
F50
Y Y Y Y
33326
999999
F51
Y Y Y Y
0xFFFFFFFF
F50
Y Y Y Y
us
0x0D15
33352
0x0D17
999999
33354
0x0D19
0xFFFFFFFF
33356
999999
us
us
F51
Y Y Y Y
F50
Y Y Y Y
F51
Y Y Y Y
Breaker 1 Status
33370
0x0D29
FC264
Y Y Y Y
33371
State
FC289
Y Y Y Y
33372
FC289
Y Y Y Y
Y Y
Breaker 2 Status
33384
0x0D37
State
FC264
33385
0x0D38
Trip Coil
FC289
Y Y
33386
0x0D39
Close Coil
FC289
Y Y
Breaker 3 Status
33398
0x0D45
State
FC264
33399
0x0D46
Trip Coil
FC289
33400
0x0D47
Close Coil
FC289
Thermal Capacity
33430
0x0D65
1500
F1
33431
0x0D66
1500
F1
Y
Y
33432
0x0D67
1500
F1
Directional Power
33450
0x0D79
Directional Power 1
-2147483648 2147483647
kW
F31
Y Y Y Y
33452
-2147483648 2147483647
kW
F31
Y Y Y Y
F32
0x0D83
Communications Status
33470
0xFFFF
FC228
Y Y Y Y
33471
0x0D8E
0xFFFFFFFF
FC323
Y Y Y Y
11-46
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
33473
0x0D90
0xFFFFFFFF
FC323A
Y Y Y Y
33475
0x0D92
0xFFFFFFFF
FC323
Y Y Y Y
33477
0x0D94
0xFFFFFFFF
FC323A
Y Y Y Y
33479
0x0D96
SNTP Status
65535
F0
Y Y Y Y
33480
0x0D97
Number of Connected
Clients
F0
Y Y Y Y
33481
0x0D98
Client 1 IP Address
0xFFFFFFFF
F70
Y Y Y Y
33483
0xFFFFFFFF
F70
Y Y Y Y
33485
0xFFFFFFFF
F70
Y Y Y Y
33487
0x0D9E
0xFFFFFFFF
F70
Y Y Y Y
Client 4 IP Address
Flex States
33490
0x0DA1 Parameter 1
65535
FC344A
Y Y Y Y
33491
0x0DA2 Parameter 2
65535
FC344B
Y Y Y Y
33492
0x0DA3 Parameter 3
65535
FC344C
Y Y Y Y
33493
0x0DA4 Parameter 4
65535
FC344D 0
Y Y Y Y
33494
0x0DA5 Parameter 5
65535
FC344E
Y Y Y Y
33495
0x0DA6 Parameter 6
65535
FC344F
Y Y Y Y
33496
0x0DA7 Parameter 7
65535
FC344G 0
Y Y Y Y
33497
0x0DA8 Parameter 8
65535
FC344H 0
Y Y Y Y
33498
0x0DA9 Parameter 9
65535
FC344I
Y Y Y Y
33499
0x0DAA Parameter 10
65535
FC344J
Y Y Y Y
33500
0x0DAB Parameter 11
65535
FC344K
Y Y Y Y
33501
0x0DAC Parameter 12
65535
FC344L
Y Y Y Y
33502
0x0DAD Parameter 13
65535
FC344M 0
Y Y Y Y
33503
0x0DAE
Parameter 14
65535
FC344N 0
Y Y Y Y
33504
0x0DAF
Parameter 15
65535
FC344O 0
Y Y Y Y
33505
0x0DB0 Parameter 16
65535
FC344P
Y Y Y Y
J Module Frequency
33540
120000
Hz
F13
Y Y Y Y
33542
-12000
12000
Hz/sec
F22
Y Y Y Y
33543
120000
Hz
F13
Y Y Y Y
33545
-12000
12000
Hz/sec
F22
Y Y Y Y
33546
120000
Hz
F13
Y Y Y Y
33548
-12000
12000
Hz/sec
F22
Y Y Y Y
K Module Frequency
33552
120000
Hz
F13
Y Y
33554
0x0DE1
-12000
12000
Hz/sec
F22
Y Y
33555
0x0DE2
K2-3VT Frequency
120000
Hz
F13
33557
0x0DE4
-12000
12000
Hz/sec
F22
33558
0x0DE5
K2-Vx Frequency
120000
Hz
F13
33560
0x0DE7
-12000
12000
Hz/sec
F22
33561
0x0DE8
K2-CT Frequency
33563
120000
Hz
F13
Y Y
-12000
12000
Hz/sec
F22
Y Y
Motor Status
11-47
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
33590
0x0E05
Motor Status
FC350
33591
0x0E06
100
F0
33592
0x0E07
65535
F0D
33593
0x0E08
65000
F0
33594
0x0E09
65000
F0
33595
0x0E0A
65000
F0
33596
0x0E0B
65000
F0
33597
0x0E0C
65000
F0
33598
0x0E0D
Motor Speed
FC351
33599
0x0E0E
100000
hrs
F10
0x0E19
Motor Load
4000
x FLA
F2
33611
0x0E1A
1000
F1
33612
0x0E1B
4000
x FLA
F2
33613
0x0E1C
4000
x FLA
F2
33614
0x0E1D
120000000
F13
33616
0x0E1F
120000000
F13
33618
0x0E21
120000000
F13
33620
0x0E23
120000000
F13
33622
0x0E25
120000000
F13
33624
0x0E27
120000000
F13
Y
Y
0x0E2D
Component Level
-1000
dB
F21
33631
0x0E2E
Component Frequency
7600
Hz
F2
33632
0x0E2F
150
x FLA
F2
33633
0x0E30
150
x FLA
F2
33634
0x0E31
0xFFFFFFFF
F50
33636
0x0E33
Maximum Component
Level
-1000
dB
F21
-10
33637
0x0E34
Maximum Component
Freq
7600
Hz
F2
33638
0x0E35
150
x FLA
F2
33639
0x0E36
150
x FLA
F2
33640
0x0E37
0xFFFFFFFF
F50
0x0E41
4000000000
F10
33652
0x0E43
0xFFFFFFFF
F50
0x0E4B
Start Date/Time
0xFFFFFFFF
F50
33662
0x0E4D
250000
F13
33664
0x0E4F
2000
x FLA
F2
33665
0x0E50
2000
x FLA
F2
11-48
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
33666
0xFFFFFFFF
F50
Y
Y
0x0E51
Start Date/Time
33668
0x0E53
250000
F13
33670
0x0E55
2000
x FLA
F2
33671
0x0E56
2000
x FLA
F2
0xFFFFFFFF
F50
Y
Y
0x0E57
Start Date/Time
33674
0x0E59
250000
F13
33676
0x0E5B
2000
x FLA
F2
33677
0x0E5C
2000
x FLA
F2
F50
F13
0x0E5D
Start Date/Time
0xFFFFFFFF
33680
0x0E5F
250000
33682
0x0E61
2000
x FLA
F2
33683
0x0E62
2000
x FLA
F2
F50
F13
0x0E63
Start Date/Time
0xFFFFFFFF
33686
0x0E65
250000
33688
0x0E67
2000
x FLA
F2
33689
0x0E68
2000
x FLA
F2
Learned Data
33700
0x0E73
65535
F0
Y Y Y Y
33701
0x0E74
0xFFFFFFFF
F50
Y Y Y Y
33703
0x0E76
Learned Acceleration
Time
250000
F13
33705
0x0E78
2000
x FLA
F2
33706
0x0E79
100
F0
33707
0x0E7A
250000
F13
33709
0x0E7C
2000
x FLA
F2
33710
0x0E7D
100
F0
33711
0x0E7E
2000
x FLA
F2
Y Y Y Y
33712
0x0E7F
Learned Average kW
-2147483648 2147483647
kW
F31
Y Y Y Y
33714
0x0E81
-2147483648 2147483647
kvar
F31
Y Y Y Y
33716
0x0E83
Learned Average PF
-99
100
F22
Y Y Y Y
33733
0x0E94
100000
days
F10
33735
0x0E96
0xFFFFFFFF
hr/min
F55
33787
0x0ECA
-41
251
?C
F20E
33788
0x0ECB
-41
251
?C
F20E
Y Y Y Y
33789
0x0ECC
-41
251
?C
F20E
Y Y Y Y
33790
-41
251
?C
F20E
Y Y Y Y
33791
0x0ECE
-41
251
?C
F20E
Y Y Y Y
33792
0x0ECF
-41
251
?C
F20E
Y Y Y Y
33793
0x0ED0
-41
251
?C
F20E
Y Y Y Y
33794
0x0ED1
-41
251
?C
F20E
Y Y Y Y
33795
0x0ED2
-41
251
?C
F20E
Y Y Y Y
33796
0x0ED3
251
?C
F20E
Y Y Y Y
Y Y Y Y
11-49
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
33797
0x0ED4
251
?C
F20E
Y Y Y Y
33798
0x0ED5
251
?C
F20E
Y Y Y Y
33799
0x0ED6
251
?C
F20E
Y Y Y Y
0x0F13
4000000000
F10
33862
0x0F15
0xFFFFFFFF
F50
0x0F27
Ia Diff
120000000
F13
Y Y
33882
0x0F29
Ib Diff
120000000
F13
Y Y
Y Y
33884
0x0F2B
Ic Diff
120000000
F13
33886
0x0F2D
Ia Restr
120000000
F13
Y Y
33888
0x0F2F
Ib Restr
120000000
F13
Y Y
Y Y
33890
0x0F31
Ic Restr
120000000
F13
33892
0x0F33
1000
F1
33893
0x0F34
1000
F1
33894
0x0F35
1000
F1
33895
0x0F36
1000
F1
33896
0x0F37
1000
F1
33897
0x0F38
1000
F1
33898
0x0F39
Ia Diff
1000000
x CT
F13
33900
0x0F3B
Ib Diff
1000000
x CT
F13
33902
0x0F3D
Ic Diff
1000000
x CT
F13
33904
0x0F3F
Ia Restr
1000000
x CT
F13
33906
0x0F41
Ib Restr
1000000
x CT
F13
33908
0x0F43
Ic Restr
1000000
x CT
F13
0x0F5B
1000
F1
33933
0x0F5C
1000
F1
33934
0x0F5D
1000
F1
33935
0x0F5E
1000
F1
33936
0x0F5F
1000
F1
33937
0x0F60
1000
F1
33938
0x0F61
Ia Ovrl Diff
1000000
x CT
F13
33940
0x0F63
Ib Ovrl Diff
1000000
x CT
F13
33942
0x0F65
Ic Ovrl Diff
1000000
x CT
F13
33944
0x0F67
Ia Ovrl Restr
1000000
x CT
F13
33946
0x0F69
Ib Ovrl Restr
1000000
x CT
F13
33948
0x0F6B
Ic Ovrl Restr
1000000
x CT
F13
0x0F77
12
33961
0x0F78
-41
251
F0
Y Y
?C
F20E
40
Y Y
F0
Y Y
?C
F20E
40
Y Y
0x0F79
12
33963
0x0F7A
-41
251
RTD
11-50
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
33980
0x0F8B
-41
251
F20E
40
33981
0x0F8C
RTD 2
-41
251
?C
F20E
40
Y Y Y Y
33982
0x0F8D
RTD 3
-41
251
?C
F20E
40
Y Y Y Y
33983
0x0F8E
RTD 4
-41
251
?C
F20E
40
Y Y Y Y
33984
0x0F8F
RTD 5
-41
251
?C
F20E
40
Y Y Y Y
33985
0x0F90
RTD 6
-41
251
?C
F20E
40
Y Y Y Y
33986
0x0F91
RTD 7
-41
251
?C
F20E
40
Y Y Y Y
33987
0x0F92
RTD 8
-41
251
?C
F20E
40
Y Y Y Y
33988
0x0F93
RTD 9
-41
251
?C
F20E
40
Y Y Y Y
33989
0x0F94
RTD 10
-41
251
?C
F20E
40
Y Y Y Y
33990
0x0F95
RTD 11
-41
251
?C
F20E
40
Y Y Y Y
33991
0x0F96
RTD 12
-41
251
?C
F20E
40
Y Y Y Y
33992
0x0F97
RTD 13
-41
251
?C
F20E
40
Y Y Y Y
0xFFFFFFFF
F50
Y Y Y Y
F20E
40
Y Y Y Y
F50
Y Y Y Y
F20E
40
Y Y Y Y
F50
Y Y Y Y
RTD 1
?C
Y Y Y Y
0x0F9F
RTD 1 Maximums
34010
0x0FA9
RTD 1 Max
-41
251
34011
0x0FAA
0xFFFFFFFF
?C
RTD 2 Maximums
34013
0x0FAC
RTD 2 Max
-41
251
34014
0x0FAD
0xFFFFFFFF
?C
RTD 3 Maximums
34016
0x0FAF
RTD 3 Max
-41
251
34017
0x0FB0
0xFFFFFFFF
?C
F20E
40
Y Y Y Y
F50
Y Y Y Y
RTD 4 Maximums
34019
0x0FB2
RTD 4 Max
-41
251
34020
0x0FB3
0xFFFFFFFF
?C
F20E
40
Y Y Y Y
F50
Y Y Y Y
RTD 5 Maximums
34022
0x0FB5
RTD 5 Max
-41
251
34023
0x0FB6
0xFFFFFFFF
?C
F20E
40
Y Y Y Y
F50
Y Y Y Y
RTD 6 Maximums
34025
0x0FB8
RTD 6 Max
-41
251
34026
0x0FB9
0xFFFFFFFF
?C
F20E
40
Y Y Y Y
F50
Y Y Y Y
RTD 7 Maximums
34028
0x0FBB
RTD 7 Max
-41
251
34029
0x0FBC
0xFFFFFFFF
?C
F20E
40
Y Y Y Y
F50
Y Y Y Y
F20E
40
Y Y Y Y
F50
Y Y Y Y
F20E
40
Y Y Y Y
F50
Y Y Y Y
F20E
40
Y Y Y Y
F50
Y Y Y Y
RTD 8 Maximums
34031
0x0FBE
RTD 8 Max
-41
251
34032
0x0FBF
0xFFFFFFFF
?C
RTD 9 Maximums
34034
0x0FC1
RTD 9 Max
-41
251
34035
0x0FC2
0xFFFFFFFF
?C
RTD 10 Maximums
34037
0x0FC4
RTD 10 Max
-41
251
34038
0x0FC5
0xFFFFFFFF
?C
11-51
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
RTD 11 Maximums
34040
0x0FC7
RTD 11 Max
-41
251
34041
0x0FC8
0xFFFFFFFF
?C
F20E
40
Y Y Y Y
F50
Y Y Y Y
RTD 12 Maximums
34043
0x0FCA
RTD 12 Max
-41
251
34044
0x0FCB
0xFFFFFFFF
?C
F20E
40
Y Y Y Y
F50
Y Y Y Y
RTD 13 Maximums
34046
-41
251
F20E
40
Y Y Y Y
34047
0x0FCE
0xFFFFFFFF
F50
Y Y Y Y
?C
Analog Inputs
34270
0x10AD Analog Ip 1
-500000
500000
UserF30
Defined
@
Modbus
49534
Y Y Y Y
34272
0x10AF
Analog Ip 2
-500000
500000
UserF30
Defined
@
Modbus
49582
Y Y Y Y
34274
0x10B1
Analog Ip 3
-500000
500000
UserF30
Defined
@
Modbus
49630
Y Y Y Y
34276
0x10B3
Analog Ip 4
-500000
500000
UserF30
Defined
@
Modbus
49678
Y Y Y Y
W1 Metering
34420
0x1143
W1 Load (% of rated)
1000
F1
34421
0x1144
W1 Average Ph Current
120000000
F13
34423
0x1146
100
F2
100
W2 Load (% of rated)
1000
F1
W2 Metering
34432
0x114F
34433
0x1150
W2 Average Ph Current
120000000
34435
0x1152
100
F13
F2
100
W3 Metering
34444
0x115B
W3 Load (% of rated)
1000
F1
34445
0x115C
W3 Average Ph Current
120000000
F13
34447
0x115E
100
F2
100
F20E
F1
F13
Thermal Elements
34460
0x116B
-41
301
34461
0x116C
Aging Factor
65535
34462
0x116D
500000000
?C
hrs
34464
0x116F
500000000
hrs
F13
34466
0x1171
-41
301
?C
F20E
34467
0x1172
Ambient Temperature
-41
301
?C
F20E
-20
40
F20D
40
11-52
0x117F
Tap Position
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
34481
0x1180
Ohms In 1
5100
ohms
F0
34482
0x1181
Winding Voltage
120000000
kV
F12
34484
0x1183
120000000
kV
F12
0x119D
400
V/Hz
F2
100
Y Y
34511
0x119E
400
V/Hz
F2
100
Y Y
Status
FC350A
FC350B
F10
FC385
Transformer Status
34520
0x11A7
Generator Status
34540
0x11BB
Generator Status
34541
0x11BC
Running Hours
1000000
34543
0x11BE
34544
0x11BF
100
F0
34545
0x11C0
65535
F0D
10001
hrs
FlexElements
34580
0x11E3
FE1 Op Signal
-30000
30000
p.u.
F23
Y Y Y Y
34581
0x11E4
FE2 Op Signal
-30000
30000
p.u.
F23
Y Y Y Y
34582
0x11E5
FE3 Op Signal
-30000
30000
p.u.
F23
Y Y Y Y
34583
0x11E6
FE4 Op Signal
-30000
30000
p.u.
F23
Y Y Y Y
34584
0x11E7
FE5 Op Signal
-30000
30000
p.u.
F23
Y Y Y Y
34585
0x11E8
FE6 Op Signal
-30000
30000
p.u.
F23
Y Y Y Y
34586
0x11E9
FE7 Op Signal
-30000
30000
p.u.
F23
Y Y Y Y
34587
0x11EA
FE8 Op Signal
-30000
30000
p.u.
F23
Y Y Y Y
400
x FLA
F1
Generator General
34610
0x1201
Load Current
34611
0x1202
Unbalance Current
10000
%FLA
F2
34613
0x1204
Excitation Current
-50000
50000
units
F30
34615
0x1206
Bearing Vibration
-50000
50000
units
F30
0x1215
9999
F1
34631
0x1216
9999
F1
34632
0x1217
9999
F1
34633
0x1218
9999
F1
34634
0x1219
9999
F1
34635
0x121A
9999
F1
34636
0x121B
9999
F1
9999
F2
0x123D
34671
0x123E
9999
F2
34672
0x123F
9999
F2
J1 Harmonic I Magnitude
34710
0x1265
0xFFFFFFFF
F13
Y Y
34712
0x1267
0xFFFFFFFF
F13
Y Y
11-53
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
34714
0xFFFFFFFF
F13
0x1269
Y Y
34716
0x126B
0xFFFFFFFF
F13
Y Y
34718
0x126D
0xFFFFFFFF
F13
Y Y
34720
0x126F
0xFFFFFFFF
F13
Y Y
K1 Harmonic I Magnitude
34734
0x127D
0xFFFFFFFF
F13
Y Y
34736
0x127F
0xFFFFFFFF
F13
Y Y
34738
0x1281
0xFFFFFFFF
F13
Y Y
34740
0x1283
0xFFFFFFFF
F13
Y Y
34742
0x1285
0xFFFFFFFF
F13
Y Y
34744
0x1287
0xFFFFFFFF
F13
Y Y
K2 Harmonic I Magnitude
34758
0x1295
0xFFFFFFFF
F13
Y Y
34760
0x1297
0xFFFFFFFF
F13
Y Y
34762
0x1299
0xFFFFFFFF
F13
Y Y
34764
0x129B
0xFFFFFFFF
F13
Y Y
34766
0x129D
0xFFFFFFFF
F13
Y Y
34768
0x129F
0xFFFFFFFF
F13
Y Y
0x12BF
Device_ID
65535
F60_32
16
34816
0x12CF
Serial Number
65535
F60_16
0xFFFFFFFF
ppm
F31
0x12E1
Hydrogen (H2)
34836
0x12E3
0xFFFFFFFF
ppm
F31
34838
0x12E5
0xFFFFFFFF
ppm
F31
34840
0x12E7
Ethylene (C2H4)
0xFFFFFFFF
ppm
F31
34842
0x12E9
Ethane (C2H6)
0xFFFFFFFF
ppm
F31
34844
0x12EB
Methane (CH4)
0xFFFFFFFF
ppm
F31
34846
0x12ED
Acetylene (C2H2)
0xFFFFFFFF
ppm
F31
34848
0x12EF
Moisture (H2O)
0xFFFFFFFF
ppm
F31
34850
0x12F1
Oxygen (O2)
0xFFFFFFFF
ppm
F31
34852
0x12F3
TDCG
0xFFFFFFFF
ppm
F31
34854
0x12F5
Nitrogen (N2)
0xFFFFFFFF
ppm
F31
34856
0x12F7
Ambient Temperature
-32768
32767
?C
F20
34857
0x12F8
Hydran (H2)
65535
ppm
F0
34858
0x12F9
65535
ppm
F0
34859
0x12FA
65535
ppm
F0
34860
0x12FB
%RH Level
1000
F1
34861
0x12FC
1000
F1
34862
0x12FD
65535
ppm
F0
34863
0x12FE
65535
ppm
F0
11-54
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
34864
0xFFFFFFFF
F50
0x12FF
Measurement Date/
Timestamp
0x130E
0xFFFFFFFF
ppm
F31
34881
0x1310
0xFFFFFFFF
ppm
F31
34883
0x1312
0xFFFFFFFF
ppm
F31
34885
0x1314
0xFFFFFFFF
ppm
F31
34887
0x1316
0xFFFFFFFF
ppm
F31
34889
0x1318
0xFFFFFFFF
ppm
F31
34891
0x131A
0xFFFFFFFF
ppm
F31
34893
0x131C
0xFFFFFFFF
ppm
F31
34895
0x131E
0xFFFFFFFF
ppm
F31
34897
0x1320
TDCG Limit
0xFFFFFFFF
ppm
F31
34899
0x1322
0xFFFFFFFF
ppm
F31
0x132E
0xFFFFFFFF
ppm
F10
34913
0x1330
0xFFFFFFFF
ppm
F10
34915
0x1332
0xFFFFFFFF
ppm
F10
34917
0x1334
0xFFFFFFFF
ppm
F10
34919
0x1336
0xFFFFFFFF
ppm
F10
34921
0x1338
0xFFFFFFFF
ppm
F10
34923
0x133A
100
F0
34924
0x133B
100
F0
34925
0x133C
100
F0
34926
0x133D
100
F0
34927
0x133E
0xFFFFFFFF
ppm
F10
34929
0x1340
0xFFFFFFFF
ppm
F10
34931
0x1342
0xFFFFFFFF
ppm
F10
34933
0x1344
0xFFFFFFFF
ppm
F10
0xFFFF
FC387
Y Y Y Y
0x1373
0x137D
HS Phase Current A
12000000
F12
Y Y Y Y
34992
0x137F
HS Phase Current B
12000000
F12
Y Y Y Y
34994
0x1381
HS Phase Current C
12000000
F12
Y Y Y Y
34996
0x1383
HS Ground Current
12000000
F12
Y Y Y Y
34998
0x1385
100
F1
Y Y Y Y
34999
0x1386
100
F1
Y Y Y Y
35000
0x1387
100
F1
Y Y Y Y
11-55
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
35001
100
F1
Y Y Y Y
0x1388
Fast Underfrequency
35050
0x13B9
Fast Frequency
2000
7000
Hz
F2
6000
35051
0x13BA
-12000
12000
Hz/sec
F22
ohms
F32
Positive Impedance 1
35100
0x13EB
Z1 Resistance
-2147483648 2147483647
35102
0x13ED
Z1 Reactance
-2147483648 2147483647
ohms
F32
35104
0x13EF
Z1 Magnitude
655350
ohms
F12
35106
0x13F1
Z1 Angle
-3599
3599
F21
Positive Impedance 2
35110
0x13F5
Z1 Resistance
-2147483648 2147483647
ohms
F32
35112
0x13F7
Z1 Reactance
-2147483648 2147483647
ohms
F32
35114
0x13F9
Z1 Magnitude
655350
ohms
F12
35116
0x13FB
Z1 Angle
-3599
3599
F21
0x13FF
Operating Quantity
20000
F3
400
35121
0x1400
Learned Unbal Z
10000
F3
200
35122
0x1401
0xFFFFFFFF
F50
35124
0x1403
20000
F3
500
35125
0x1404
10000
F3
200
1000
F1
Harmonic Detection J1
35140
0x1413
HD J1 Ph A 2nd Harm
Y Y Y Y
35141
0x1414
HD J1 Ph B 2nd Harm
1000
F1
Y Y Y Y
35142
0x1415
HD J1 Ph C 2nd Harm
1000
F1
Y Y Y Y
35143
0x1416
HD J1 Ph A 3rd Harm
1000
F1
Y Y Y Y
35144
0x1417
HD J1 Ph B 3rd Harm
1000
F1
Y Y Y Y
35145
0x1418
HD J1 Ph C 3rd Harm
1000
F1
Y Y Y Y
35146
0x1419
HD J1 Ph A 4th Harm
1000
F1
Y Y Y Y
35147
0x141A
HD J1 Ph B 4th Harm
1000
F1
Y Y Y Y
35148
0x141B
HD J1 Ph C 4th Harm
1000
F1
Y Y Y Y
35149
0x141C
HD J1 Ph A 5th Harm
1000
F1
Y Y Y Y
35150
0x141D
HD J1 Ph B 5th Harm
1000
F1
Y Y Y Y
35151
0x141E
HD J1 Ph C 5th Harm
1000
F1
Y Y Y Y
Harmonic Detection K1
35152
0x141F
HD K1 Ph A 2nd Harm
1000
F1
Y Y
35153
0x1420
HD K1 Ph B 2nd Harm
1000
F1
Y Y
35154
0x1421
HD K1 Ph C 2nd Harm
1000
F1
Y Y
35155
0x1422
HD K1 Ph A 3rd Harm
1000
F1
Y Y
35156
0x1423
HD K1 Ph B 3rd Harm
1000
F1
Y Y
35157
0x1424
HD K1 Ph C 3rd Harm
1000
F1
Y Y
35158
0x1425
HD K1 Ph A 4th Harm
1000
F1
Y Y
35159
0x1426
HD K1 Ph B 4th Harm
1000
F1
Y Y
35160
0x1427
HD K1 Ph C 4th Harm
1000
F1
Y Y
35161
0x1428
HD K1 Ph A 5th Harm
1000
F1
Y Y
35162
0x1429
HD K1 Ph B 5th Harm
1000
F1
Y Y
11-56
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
35163
1000
F1
0x142A
HD K1 Ph C 5th Harm
Y Y
Harmonic Detection K2
35164
0x142B
HD K2 Ph A 2nd Harm
1000
F1
Y Y
35165
0x142C
HD K2 Ph B 2nd Harm
1000
F1
Y Y
35166
0x142D
HD K2 Ph C 2nd Harm
1000
F1
Y Y
35167
0x142E
HD K2 Ph A 3rd Harm
1000
F1
Y Y
35168
0x142F
HD K2 Ph B 3rd Harm
1000
F1
Y Y
35169
0x1430
HD K2 Ph C 3rd Harm
1000
F1
Y Y
35170
0x1431
HD K2 Ph A 4th Harm
1000
F1
Y Y
35171
0x1432
HD K2 Ph B 4th Harm
1000
F1
Y Y
35172
0x1433
HD K2 Ph C 4th Harm
1000
F1
Y Y
35173
0x1434
HD K2 Ph A 5th Harm
1000
F1
Y Y
35174
0x1435
HD K2 Ph B 5th Harm
1000
F1
Y Y
35175
0x1436
HD K2 Ph C 5th Harm
1000
F1
Y Y
0x1445
Cause
0xFFFFFFFF
FC134
Y Y Y Y
35192
0x1447
Event
4294967295
F10
Y Y Y Y
35194
0x1449
Date/Time
0xFFFFFFFF
F50
Y Y Y Y
35196
0x144B
Time (us)
999999
F51
Y Y Y Y
35198
0x144D
Parameter 1
-2147483648 2147483647
F30
Y Y Y Y
35200
0x144F
Parameter 2
-2147483648 2147483647
F30
Y Y Y Y
35202
0x1451
Parameter 3
-2147483648 2147483647
F30
Y Y Y Y
35204
0x1453
Parameter 4
-2147483648 2147483647
F30
Y Y Y Y
35206
0x1455
Parameter 5
-2147483648 2147483647
F30
Y Y Y Y
35208
0x1457
Parameter 6
-2147483648 2147483647
F30
Y Y Y Y
35210
0x1459
Parameter 7
-2147483648 2147483647
F30
Y Y Y Y
35212
0x145B
Parameter 8
-2147483648 2147483647
F30
Y Y Y Y
35214
0x145D
Parameter 9
-2147483648 2147483647
F30
Y Y Y Y
35216
0x145F
Parameter 10
-2147483648 2147483647
F30
Y Y Y Y
35218
0x1461
Parameter 11
-2147483648 2147483647
F30
Y Y Y Y
35220
0x1463
Parameter 12
-2147483648 2147483647
F30
Y Y Y Y
35222
0x1465
Parameter 13
-2147483648 2147483647
F30
Y Y Y Y
35224
0x1467
Parameter 14
-2147483648 2147483647
F30
Y Y Y Y
35226
0x1469
Parameter 15
-2147483648 2147483647
F30
Y Y Y Y
35228
0x146B
Parameter 16
-2147483648 2147483647
F30
Y Y Y Y
35230
0x146D
Parameter 17
-2147483648 2147483647
F30
Y Y Y Y
35232
0x146F
Parameter 18
-2147483648 2147483647
F30
Y Y Y Y
35234
0x1471
Parameter 19
-2147483648 2147483647
F30
Y Y Y Y
35236
0x1473
Parameter 20
-2147483648 2147483647
F30
Y Y Y Y
35238
0x1475
Parameter 21
-2147483648 2147483647
F30
Y Y Y Y
35240
0x1477
Parameter 22
-2147483648 2147483647
F30
Y Y Y Y
35242
0x1479
Parameter 23
-2147483648 2147483647
F30
Y Y Y Y
35244
0x147B
Parameter 24
-2147483648 2147483647
F30
Y Y Y Y
35246
0x147D
Parameter 25
-2147483648 2147483647
F30
Y Y Y Y
35248
0x147F
Parameter 26
-2147483648 2147483647
F30
Y Y Y Y
us
11-57
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
35250
0x1481
Parameter 27
-2147483648 2147483647
F30
Y Y Y Y
35252
0x1483
35254
0x1485
Parameter 28
-2147483648 2147483647
F30
Y Y Y Y
Parameter 29
-2147483648 2147483647
F30
35256
0x1487
Y Y Y Y
Parameter 30
-2147483648 2147483647
F30
Y Y Y Y
35258
35260
0x1489
Parameter 31
-2147483648 2147483647
F30
Y Y Y Y
0x148B
Parameter 32
-2147483648 2147483647
F30
Y Y Y Y
35262
0x148D
Parameter 33
-2147483648 2147483647
F30
Y Y Y Y
35264
0x148F
Parameter 34
-2147483648 2147483647
F30
Y Y Y Y
35266
0x1491
Parameter 35
-2147483648 2147483647
F30
Y Y Y Y
35268
0x1493
Parameter 36
-2147483648 2147483647
F30
Y Y Y Y
35270
0x1495
Parameter 37
-2147483648 2147483647
F30
Y Y Y Y
35272
0x1497
Parameter 38
-2147483648 2147483647
F30
Y Y Y Y
35274
0x1499
Parameter 39
-2147483648 2147483647
F30
Y Y Y Y
35276
0x149B
Parameter 40
-2147483648 2147483647
F30
Y Y Y Y
35278
0x149D
Parameter 41
-2147483648 2147483647
F30
Y Y Y Y
35280
0x149F
Parameter 42
-2147483648 2147483647
F30
Y Y Y Y
35282
0x14A1
Parameter 43
-2147483648 2147483647
F30
Y Y Y Y
35284
0x14A3
Parameter 44
-2147483648 2147483647
F30
Y Y Y Y
35286
0x14A5
Parameter 45
-2147483648 2147483647
F30
Y Y Y Y
35288
0x14A7
Parameter 46
-2147483648 2147483647
F30
Y Y Y Y
35290
0x14A9
Parameter 47
-2147483648 2147483647
F30
Y Y Y Y
35292
0x14AB
Parameter 48
-2147483648 2147483647
F30
Y Y Y Y
35294
0x14AD Parameter 49
-2147483648 2147483647
F30
Y Y Y Y
35296
0x14AF
Parameter 50
-2147483648 2147483647
F30
Y Y Y Y
35298
0x14B1
Parameter 51
-2147483648 2147483647
F30
Y Y Y Y
35300
0x14B3
Parameter 52
-2147483648 2147483647
F30
Y Y Y Y
35302
0x14B5
Parameter 53
-2147483648 2147483647
F30
Y Y Y Y
35304
0x14B7
Parameter 54
-2147483648 2147483647
F30
Y Y Y Y
35306
0x14B9
Parameter 55
-2147483648 2147483647
F30
Y Y Y Y
35308
0x14BB
Parameter 56
-2147483648 2147483647
F30
Y Y Y Y
35310
0x14BD Parameter 57
-2147483648 2147483647
F30
Y Y Y Y
35312
0x14BF
Parameter 58
-2147483648 2147483647
F30
Y Y Y Y
35314
0x14C1
Parameter 59
-2147483648 2147483647
F30
Y Y Y Y
35316
0x14C3
Parameter 60
-2147483648 2147483647
F30
Y Y Y Y
35318
0x14C5
Parameter 61
-2147483648 2147483647
F30
Y Y Y Y
35320
0x14C7
Parameter 62
-2147483648 2147483647
F30
Y Y Y Y
35322
0x14C9
Parameter 63
-2147483648 2147483647
F30
Y Y Y Y
35324
0x14CB
Parameter 64
-2147483648 2147483647
F30
Y Y Y Y
0x14DB Event
4294967295
F10
Y Y Y Y
35342
0x14DD Cause
0xFFFFFFFF
FC134
Y Y Y Y
35344
0x14DF
Date/Time
0xFFFFFFFF
F50
Y Y Y Y
35346
0x14E1
999999
F51
Y Y Y Y
35348
0x14E3
Parameter 1
-2147483648 2147483647
F30
Y Y Y Y
35350
0x14E5
Parameter 2
-2147483648 2147483647
F30
Y Y Y Y
11-58
us
Modbus Hex
Description
Address Address
Min
35352
0x14E7
-2147483648 2147483647
35354
0x14E9
Parameter 4
-2147483648 2147483647
F30
Y Y Y Y
35356
0x14EB
Parameter 5
-2147483648 2147483647
F30
Y Y Y Y
35358
0x14ED
Parameter 6
-2147483648 2147483647
F30
Y Y Y Y
35360
0x14EF
Parameter 7
-2147483648 2147483647
F30
Y Y Y Y
35362
0x14F1
Parameter 8
-2147483648 2147483647
F30
Y Y Y Y
35364
0x14F3
Parameter 9
-2147483648 2147483647
F30
Y Y Y Y
35366
0x14F5
Parameter 10
-2147483648 2147483647
F30
Y Y Y Y
35368
0x14F7
Parameter 11
-2147483648 2147483647
F30
Y Y Y Y
35370
0x14F9
Parameter 12
-2147483648 2147483647
F30
Y Y Y Y
35372
0x14FB
Parameter 13
-2147483648 2147483647
F30
Y Y Y Y
35374
0x14FD
Parameter 14
-2147483648 2147483647
F30
Y Y Y Y
35376
0x14FF
Parameter 15
-2147483648 2147483647
F30
Y Y Y Y
35378
0x1501
Parameter 16
-2147483648 2147483647
F30
Y Y Y Y
35380
0x1503
Parameter 17
-2147483648 2147483647
F30
Y Y Y Y
35382
0x1505
Parameter 18
-2147483648 2147483647
F30
Y Y Y Y
35384
0x1507
Parameter 19
-2147483648 2147483647
F30
Y Y Y Y
35386
0x1509
Parameter 20
-2147483648 2147483647
F30
Y Y Y Y
35388
0x150B
Parameter 21
-2147483648 2147483647
F30
Y Y Y Y
35390
0x150D
Parameter 22
-2147483648 2147483647
F30
Y Y Y Y
35392
0x150F
Parameter 23
-2147483648 2147483647
F30
Y Y Y Y
35394
0x1511
Parameter 24
-2147483648 2147483647
F30
Y Y Y Y
35396
0x1513
Parameter 25
-2147483648 2147483647
F30
Y Y Y Y
35398
0x1515
Parameter 26
-2147483648 2147483647
F30
Y Y Y Y
35400
0x1517
Parameter 27
-2147483648 2147483647
F30
Y Y Y Y
35402
0x1519
Parameter 28
-2147483648 2147483647
F30
Y Y Y Y
35404
0x151B
Parameter 29
-2147483648 2147483647
F30
Y Y Y Y
35406
0x151D
Parameter 30
-2147483648 2147483647
F30
Y Y Y Y
35408
0x151F
Parameter 31
-2147483648 2147483647
F30
Y Y Y Y
35410
0x1521
Parameter 32
-2147483648 2147483647
F30
Y Y Y Y
35412
0x1523
Parameter 33
-2147483648 2147483647
F30
Y Y Y Y
35414
0x1525
Parameter 34
-2147483648 2147483647
F30
Y Y Y Y
35416
0x1527
Parameter 35
-2147483648 2147483647
F30
Y Y Y Y
35418
0x1529
Parameter 36
-2147483648 2147483647
F30
Y Y Y Y
35420
0x152B
Parameter 37
-2147483648 2147483647
F30
Y Y Y Y
35422
0x152D
Parameter 38
-2147483648 2147483647
F30
Y Y Y Y
35424
0x152F
Parameter 39
-2147483648 2147483647
F30
Y Y Y Y
35426
0x1531
Parameter 40
-2147483648 2147483647
F30
Y Y Y Y
35428
0x1533
Parameter 41
-2147483648 2147483647
F30
Y Y Y Y
35430
0x1535
Parameter 42
-2147483648 2147483647
F30
Y Y Y Y
35432
0x1537
Parameter 43
-2147483648 2147483647
F30
Y Y Y Y
35434
0x1539
Parameter 44
-2147483648 2147483647
F30
Y Y Y Y
35436
0x153B
Parameter 45
-2147483648 2147483647
F30
Y Y Y Y
35438
0x153D
Parameter 46
-2147483648 2147483647
F30
Y Y Y Y
35440
0x153F
Parameter 47
-2147483648 2147483647
F30
Y Y Y Y
Parameter 3
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
F30
Y Y Y Y
11-59
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
35442
0x1541
Parameter 48
-2147483648 2147483647
F30
Y Y Y Y
35444
0x1543
35446
0x1545
Parameter 49
-2147483648 2147483647
F30
Y Y Y Y
Parameter 50
-2147483648 2147483647
F30
35448
0x1547
Y Y Y Y
Parameter 51
-2147483648 2147483647
F30
Y Y Y Y
35450
35452
0x1549
Parameter 52
-2147483648 2147483647
F30
Y Y Y Y
0x154B
Parameter 53
-2147483648 2147483647
F30
Y Y Y Y
35454
0x154D
Parameter 54
-2147483648 2147483647
F30
Y Y Y Y
35456
0x154F
Parameter 55
-2147483648 2147483647
F30
Y Y Y Y
35458
0x1551
Parameter 56
-2147483648 2147483647
F30
Y Y Y Y
35460
0x1553
Parameter 57
-2147483648 2147483647
F30
Y Y Y Y
35462
0x1555
Parameter 58
-2147483648 2147483647
F30
Y Y Y Y
35464
0x1557
Parameter 59
-2147483648 2147483647
F30
Y Y Y Y
35466
0x1559
Parameter 60
-2147483648 2147483647
F30
Y Y Y Y
35468
0x155B
Parameter 61
-2147483648 2147483647
F30
Y Y Y Y
35470
0x155D
Parameter 62
-2147483648 2147483647
F30
Y Y Y Y
35472
0x155F
Parameter 63
-2147483648 2147483647
F30
Y Y Y Y
35474
0x1561
Parameter 64
-2147483648 2147483647
F30
Y Y Y Y
0x157B
Device Status
FC350C
Y Y Y Y
35501
0x157C
0xFFFFFFFF
F50
Y Y Y Y
35503
0x157E
0xFFFFFFFF
FC394
Y Y Y Y
35505
0x1580
0xFFFFFFFF
FC395
Y Y Y Y
35507
0x1582
BSG3 - Temp C 1
-2147483648 2147483647
F30
Y Y Y Y
35509
0x1584
BSG3 - Temp C 2
-2147483648 2147483647
F30
Y Y Y Y
35511
0x1586
BSG3 - Temp C 3
-2147483648 2147483647
F30
Y Y Y Y
35513
0x1588
BSG3 - Temp C 4
-2147483648 2147483647
F30
Y Y Y Y
35515
0x158A
BSG3 - Temp C 5
-2147483648 2147483647
F30
Y Y Y Y
35517
0x158C
BSG3 - Temp C 6
-2147483648 2147483647
F30
Y Y Y Y
35519
0x158E
BSG3 - Temp C 7
-2147483648 2147483647
F30
Y Y Y Y
35521
0x1590
BSG3 - Temp C 8
-2147483648 2147483647
F30
Y Y Y Y
35523
0x1592
BSG3 - Temp C 9
-2147483648 2147483647
F30
Y Y Y Y
35525
0x1594
BSG3 - Temp F 1
-2147483648 2147483647
F30
Y Y Y Y
35527
0x1596
BSG3 - Temp F 2
-2147483648 2147483647
F30
Y Y Y Y
35529
0x1598
BSG3 - Temp F 3
-2147483648 2147483647
F30
Y Y Y Y
35531
0x159A
BSG3 - Temp F 4
-2147483648 2147483647
F30
Y Y Y Y
35533
0x159C
BSG3 - Temp F 5
-2147483648 2147483647
F30
Y Y Y Y
35535
0x159E
BSG3 - Temp F 6
-2147483648 2147483647
F30
Y Y Y Y
35537
0x15A0
BSG3 - Temp F 7
-2147483648 2147483647
F30
Y Y Y Y
35539
0x15A2
BSG3 - Temp F 8
-2147483648 2147483647
F30
Y Y Y Y
35541
0x15A4
BSG3 - Temp F 9
-2147483648 2147483647
F30
Y Y Y Y
35543
0x15A6
BSG3 - Power 1
-2147483648 2147483647
F30
Y Y Y Y
35545
0x15A8
BSG3 - Power 2
-2147483648 2147483647
F30
Y Y Y Y
35547
0x15AA
BSG3 - Power 3
-2147483648 2147483647
F30
Y Y Y Y
35549
0x15AC
BSG3 - Power 4
-2147483648 2147483647
F30
Y Y Y Y
35551
0x15AE
BSG3 - Power 5
-2147483648 2147483647
F30
Y Y Y Y
11-60
Modbus Hex
Description
Address Address
Min
35553
0x15B0
BSG3 - Power 6
35555
0x15B2
35557
0x15B4
35559
0x15B6
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
-2147483648 2147483647
F30
Y Y Y Y
BSG3 - Power 7
-2147483648 2147483647
F30
Y Y Y Y
BSG3 - Power 8
-2147483648 2147483647
F30
Y Y Y Y
BSG3 - Power 9
-2147483648 2147483647
F30
Y Y Y Y
0x0000
Version
160
160
F0
160
Y Y Y Y
40002
0x0001
Date
0x031707E0
0x031707E0
F10
0x031707 2
E0
Y Y Y Y
40004
0x0003
Time
0x0E2C2000
0x0E2C2000
F10
0x0E2C20 2
00
Y Y Y Y
40006
0x0005
SPChangeDateTime
0xFFFFFFFF
F50
Y Y Y Y
40008
0x0007
SPChangeuSeconds
999999
F51
Y Y Y Y
us
Modbus Commands
40129
0x0080
Command Address
65535
F1
Y Y Y Y
40130
0x0081
Command Function
65535
F1
Y Y Y Y
40131
0x0082
Command Data 1
65535
F1
Y Y Y Y
40132
0x0083
Command Data 2
65535
F1
Y Y Y Y
40133
0x0084
Command Data 3
65535
F1
Y Y Y Y
40134
0x0085
Command Data 4
65535
F1
Y Y Y Y
40135
0x0086
Command Data 5
65535
F1
Y Y Y Y
40136
0x0087
Command Data 6
65535
F1
Y Y Y Y
40137
0x0088
Command Data 7
65535
F1
Y Y Y Y
40138
0x0089
Command Data 8
65535
F1
Y Y Y Y
40139
0x008A
Command Data 9
65535
F1
Y Y Y Y
40140
0x008B
Command Data 10
65535
F1
Y Y Y Y
256
F0
Y Y Y Y
0x00E5
Clock
40241
0x00F0
Time
0x173B3B63
F54
Y Y Y Y
40243
0x00F2
Date
0x010107D8
0x0C1F082E
F53
16844760 2
Y Y Y Y
40245
0x00F4
RTC Time
0xFFFFFFFF
F52
Y Y Y Y
40247
0x00F6
-240
240
hrs
F21
Y Y Y Y
40248
0x00F7
FC126
Y Y Y Y
40249
0x00F8
FC126
Y Y Y Y
40250
0x00F9
12
FC169
Y Y Y Y
40251
0x00FA
FC170
Y Y Y Y
40252
0x00FB
FC171
Y Y Y Y
40253
0x00FC
23
F0
Y Y Y Y
40254
0x00FD
12
FC169
Y Y Y Y
40255
0x00FE
FC170
Y Y Y Y
40256
0x00FF
FC171
Y Y Y Y
40257
0x0100
23
F0
Y Y Y Y
40258
0x0101
IRIG-B
FC126
Y Y Y Y
11-61
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
0x010D
FC126
Y Y Y Y
40271
0x010E
60000
ns
F0
Y Y Y Y
40272
0x010F
-1000
1000
ns
F20
Y Y Y Y
40273
0x0110
FC126
Y Y Y Y
40274
0x0111
60000
ns
F0
Y Y Y Y
40275
0x0112
-1000
1000
ns
F20
Y Y Y Y
40276
0x0113
FC126
Y Y Y Y
40277
0x0114
255
F0
Y Y Y Y
40278
0x0115
F0
Y Y Y Y
40279
0x0116
PTP VLAN ID
4095
F0
Y Y Y Y
40280
0x0117
PTP Priority
F0
Y Y Y Y
40300
0x012B
SNTP Function
FC126
Y Y Y Y
40301
0x012C
0xFFFFFFFF
F70
Y Y Y Y
40303
0x012E
65535
F0A
123
Y Y Y Y
SNTP
0x020B
30001
49999
F0
30712
Y Y Y Y
40525
0x020C
30001
49999
F0
30713
Y Y Y Y
40526
0x020D
30001
49999
F0
30708
Y Y Y Y
40527
0x020E
30001
49999
F0
30709
Y Y Y Y
40528
0x020F
30001
49999
F0
30700
Y Y Y Y
40529
0x0210
30001
49999
F0
30701
Y Y Y Y
40530
0x0211
30001
49999
F0
30706
Y Y Y Y
40531
0x0212
30001
49999
F0
30707
Y Y Y Y
40532
0x0213
30001
49999
F0
30714
Y Y Y Y
40533
0x0214
30001
49999
F0
30715
Y Y Y Y
40534
0x0215
30001
49999
F0
30722
Y Y Y Y
40535
0x0216
30001
49999
F0
30723
Y Y Y Y
40536
0x0217
30001
49999
F0
30734
Y Y Y Y
40537
0x0218
30001
49999
F0
30735
Y Y Y Y
40538
0x0219
30001
49999
F0
30742
Y Y Y Y
40539
0x021A
30001
49999
F0
30743
Y Y Y Y
40540
0x021B
30001
49999
F0
31270
Y Y Y Y
40541
0x021C
30001
49999
F0
31271
Y Y Y Y
40542
0x021D
30001
49999
F0
31272
Y Y Y Y
40543
0x021E
30001
49999
F0
31273
Y Y Y Y
40544
0x021F
30001
49999
F0
31274
Y Y Y Y
40545
0x0220
30001
49999
F0
31275
Y Y Y Y
40546
0x0221
30001
49999
F0
31278
Y Y Y Y
40547
0x0222
30001
49999
F0
31279
Y Y Y Y
40548
0x0223
30001
49999
F0
31295
Y Y Y Y
40549
0x0224
30001
49999
F0
31296
Y Y Y Y
40550
0x0225
30001
49999
F0
31276
Y Y Y Y
11-62
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
40551
0x0226
30001
49999
F0
31277
Y Y Y Y
40552
0x0227
30001
49999
F0
31446
Y Y Y Y
40553
0x0228
30001
49999
F0
31447
Y Y Y Y
40554
0x0229
30001
49999
F0
31448
Y Y Y Y
40555
0x022A
30001
49999
F0
31449
Y Y Y Y
40556
0x022B
30001
49999
F0
31450
Y Y Y Y
40557
0x022C
30001
49999
F0
31451
Y Y Y Y
40558
0x022D
30001
49999
F0
31452
Y Y Y Y
40559
0x022E
30001
49999
F0
31453
Y Y Y Y
40560
0x022F
30001
49999
F0
31454
Y Y Y Y
40561
0x0230
30001
49999
F0
31455
Y Y Y Y
40562
0x0231
30001
49999
F0
31456
Y Y Y Y
40563
0x0232
30001
49999
F0
31457
Y Y Y Y
40564
0x0233
30001
49999
F0
31470
Y Y Y Y
40565
0x0234
30001
49999
F0
31471
Y Y Y Y
40566
0x0235
30001
49999
F0
31472
Y Y Y Y
40567
0x0236
30001
49999
F0
31473
Y Y Y Y
40568
0x0237
30001
49999
F0
32020
Y Y Y Y
40569
0x0238
30001
49999
F0
32021
Y Y Y Y
40570
0x0239
30001
49999
F0
32024
Y Y Y Y
40571
0x023A
30001
49999
F0
32025
Y Y Y Y
40572
0x023B
30001
49999
F0
32044
Y Y Y Y
40573
0x023C
30001
49999
F0
33540
Y Y Y Y
40574
0x023D
30001
49999
F0
33541
Y Y Y Y
40575
0x023E
30001
49999
F0
31965
Y Y Y Y
40576
0x023F
30001
49999
F0
31966
Y Y Y Y
40577
0x0240
30001
49999
F0
31967
Y Y Y Y
40578
0x0241
30001
49999
F0
31968
Y Y Y Y
40579
0x0242
30001
49999
F0
31969
Y Y Y Y
40580
0x0243
30001
49999
F0
32114
Y Y Y Y
40581
0x0244
30001
49999
F0
32115
Y Y Y Y
40582
0x0245
30001
49999
F0
32026
Y Y Y Y
40583
0x0246
30001
49999
F0
32027
Y Y Y Y
40584
0x0247
30001
49999
F0
32038
Y Y Y Y
40585
0x0248
30001
49999
F0
32039
Y Y Y Y
40586
0x0249
30001
49999
F0
32045
Y Y Y Y
40587
0x024A
30001
49999
F0
32028
Y Y Y Y
40588
0x024B
30001
49999
F0
32029
Y Y Y Y
40589
0x024C
30001
49999
F0
32040
Y Y Y Y
40590
0x024D
30001
49999
F0
32041
Y Y Y Y
40591
0x024E
30001
49999
F0
32046
Y Y Y Y
40592
0x024F
30001
49999
F0
32030
Y Y Y Y
40593
0x0250
30001
49999
F0
32031
Y Y Y Y
40594
0x0251
30001
49999
F0
32042
Y Y Y Y
40595
0x0252
30001
49999
F0
32043
Y Y Y Y
11-63
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
40596
0x0253
30001
49999
F0
32047
Y Y Y Y
40597
0x0254
30001
49999
F0
32022
Y Y Y Y
40598
0x0255
30001
49999
F0
32023
Y Y Y Y
40599
0x0256
30001
49999
F0
32032
Y Y Y Y
40600
0x0257
30001
49999
F0
32033
Y Y Y Y
40601
0x0258
30001
49999
F0
32034
Y Y Y Y
40602
0x0259
30001
49999
F0
32035
Y Y Y Y
40603
0x025A
30001
49999
F0
32036
Y Y Y Y
40604
0x025B
30001
49999
F0
32037
Y Y Y Y
40605
0x025C
30001
49999
F0
30001
Y Y Y Y
40606
0x025D
30001
49999
F0
30001
Y Y Y Y
40607
0x025E
30001
49999
F0
30001
Y Y Y Y
40608
0x025F
30001
49999
F0
30001
Y Y Y Y
40609
0x0260
30001
49999
F0
30001
Y Y Y Y
40610
0x0261
30001
49999
F0
30001
Y Y Y Y
40611
0x0262
30001
49999
F0
30001
Y Y Y Y
40612
0x0263
30001
49999
F0
30001
Y Y Y Y
40613
0x0264
30001
49999
F0
30001
Y Y Y Y
40614
0x0265
30001
49999
F0
30001
Y Y Y Y
40615
0x0266
30001
49999
F0
30001
Y Y Y Y
40616
0x0267
30001
49999
F0
30001
Y Y Y Y
40617
0x0268
30001
49999
F0
30001
Y Y Y Y
40618
0x0269
30001
49999
F0
30001
Y Y Y Y
40619
0x026A
30001
49999
F0
30001
Y Y Y Y
40620
0x026B
30001
49999
F0
30001
Y Y Y Y
40621
0x026C
30001
49999
F0
30001
Y Y Y Y
40622
0x026D
30001
49999
F0
30001
Y Y Y Y
40623
0x026E
30001
49999
F0
30001
Y Y Y Y
40624
0x026F
30001
49999
F0
30001
Y Y Y Y
40625
0x0270
30001
49999
F0
30001
Y Y Y Y
40626
0x0271
30001
49999
F0
30001
Y Y Y Y
40627
0x0272
30001
49999
F0
30001
Y Y Y Y
40628
0x0273
30001
49999
F0
30001
Y Y Y Y
40629
0x0274
30001
49999
F0
30001
Y Y Y Y
40630
0x0275
30001
49999
F0
30001
Y Y Y Y
40631
0x0276
30001
49999
F0
30001
Y Y Y Y
40632
0x0277
30001
49999
F0
30001
Y Y Y Y
40633
0x0278
30001
49999
F0
30001
Y Y Y Y
40634
0x0279
30001
49999
F0
30001
Y Y Y Y
40635
0x027A
30001
49999
F0
30001
Y Y Y Y
40636
0x027B
30001
49999
F0
30001
Y Y Y Y
40637
0x027C
30001
49999
F0
30001
Y Y Y Y
40638
0x027D
30001
49999
F0
30001
Y Y Y Y
40639
0x027E
30001
49999
F0
30001
Y Y Y Y
40640
0x027F
30001
49999
F0
30001
Y Y Y Y
11-64
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
40641
0x0280
30001
49999
F0
30001
Y Y Y Y
40642
0x0281
30001
49999
F0
30001
Y Y Y Y
40643
0x0282
30001
49999
F0
30001
Y Y Y Y
40644
0x0283
30001
49999
F0
30001
Y Y Y Y
40645
0x0284
30001
49999
F0
30001
Y Y Y Y
40646
0x0285
30001
49999
F0
30001
Y Y Y Y
40647
0x0286
30001
49999
F0
30001
Y Y Y Y
40648
0x0287
30001
49999
F0
30001
Y Y Y Y
0x0293
Enable Events
FC126
Y Y Y Y
40661
0x0294
Event Selector
4294967295
F10
Y Y Y Y
Y Y Y Y
Clear Records
40692
0x02B3
FC126B
40693
0x02B4
FC126B
40694
0x02B5
Running Hours
FC126B
40695
0x02B6
FC126B
Y
Y
40696
0x02B7
Xfmr Energization
Records
FC126B
40697
0x02B8
FC126B
40698
0x02B9
FC126B
40699
0x02BA
DGA History
FC126B
40700
0x02BB
All Records
FC126B
Y Y Y Y
40701
0x02BC
Targets
FC126B
Y Y Y Y
Y Y Y Y
40702
FC126B
40703
0x02BE
Transient Records
FC126B
Y Y Y Y
40704
0x02BF
Data Logger
FC126B
Y Y Y Y
40705
0x02C0
Fault Reports
FC126B
40706
0x02C1
FC126B
Y Y Y Y
40707
0x02C2
FC126B
Y Y Y Y
40708
0x02C3
FC126B
Y Y Y Y
40709
0x02C4
FC126B
Y Y Y Y
40710
0x02C5
FC126B
Y Y Y Y
40711
0x02C6
Thermal Capacity
FC126B
Y Y Y
40712
0x02C7
Digital Counters
FC126B
Y Y Y Y
40713
0x02C8
FC126B
Y Y Y Y
40714
0x02C9
FC126B
Y Y Y Y
40715
0x02CA
FC126B
Y Y
40716
0x02CB
FC126B
Y Y
40717
0x02CC
FC126B
40718
FC126B
40720
0x02CF
Autoreclose
FC126B
40722
0x02D1
FC126B
40723
0x02D2
FC126B
40724
0x02D3
FC126B
Y
Y
11-65
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
40725
FC126B
0x02D4
40726
0x02D5
RTD Maximums
FC126B
40727
0x02D6
FC126B
Y Y Y Y
40728
0x02D7
FC126B
40730
0x02D9
Timer 1 Type
FC141
Y Y Y Y
40731
60000
F0
Y Y Y Y
40732
60000
F0
Y Y Y Y
40733
FC141
Y Y Y Y
40734
60000
F0
Y Y Y Y
40735
0x02DE
60000
F0
Y Y Y Y
40736
0x02DF
Timer 3 Type
FC141
Y Y Y Y
40737
0x02E0
60000
F0
Y Y Y Y
40738
0x02E1
60000
F0
Y Y Y Y
40739
0x02E2
Timer 4 Type
FC141
Y Y Y Y
40740
0x02E3
60000
F0
Y Y Y Y
40741
0x02E4
60000
F0
Y Y Y Y
40742
0x02E5
Timer 5 Type
FC141
Y Y Y Y
40743
0x02E6
60000
F0
Y Y Y Y
40744
0x02E7
60000
F0
Y Y Y Y
40745
0x02E8
Timer 6 Type
FC141
Y Y Y Y
40746
0x02E9
60000
F0
Y Y Y Y
40747
0x02EA
60000
F0
Y Y Y Y
40748
0x02EB
Timer 7 Type
FC141
Y Y Y Y
40749
0x02EC
60000
F0
Y Y Y Y
40750
0x02ED
60000
F0
Y Y Y Y
40751
0x02EE
Timer 8 Type
FC141
Y Y Y Y
40752
0x02EF
60000
F0
Y Y Y Y
40753
0x02F0
60000
F0
Y Y Y Y
40754
0x02F1
Timer 9 Type
FC141
Y Y Y Y
40755
0x02F2
60000
F0
Y Y Y Y
40756
0x02F3
60000
F0
Y Y Y Y
40757
0x02F4
Timer 10 Type
FC141
Y Y Y Y
40758
0x02F5
60000
F0
Y Y Y Y
40759
0x02F6
60000
F0
Y Y Y Y
Timer 1
Timer 2
Timer 3
Timer 4
Timer 5
Timer 6
Timer 7
Timer 8
Timer 9
Timer 10
Timer 11
11-66
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
40760
0x02F7
Timer 11 Type
FC141
Y Y Y Y
40761
0x02F8
60000
F0
Y Y Y Y
40762
0x02F9
60000
F0
Y Y Y Y
40763
0x02FA
Timer 12 Type
FC141
Y Y Y Y
40764
0x02FB
60000
F0
Y Y Y Y
40765
0x02FC
60000
F0
Y Y Y Y
40766
0x02FD
Timer 13 Type
FC141
Y Y Y Y
40767
0x02FE
60000
F0
Y Y Y Y
40768
0x02FF
60000
F0
Y Y Y Y
40769
0x0300
Timer 14 Type
FC141
Y Y Y Y
40770
0x0301
60000
F0
Y Y Y Y
40771
0x0302
60000
F0
Y Y Y Y
40772
0x0303
Timer 15 Type
FC141
Y Y Y Y
40773
0x0304
60000
F0
Y Y Y Y
40774
0x0305
60000
F0
Y Y Y Y
40775
0x0306
Timer 16 Type
FC141
Y Y Y Y
40776
0x0307
60000
F0
Y Y Y Y
40777
0x0308
60000
F0
Y Y Y Y
40778
0x0309
Timer 17 Type
FC141
Y Y Y Y
40779
0x030A
60000
F0
Y Y Y Y
40780
0x030B
60000
F0
Y Y Y Y
Timer 12
Timer 13
Timer 14
Timer 15
Timer 16
Timer 17
Timer 18
40781
0x030C
Timer 18 Type
FC141
Y Y Y Y
40782
0x030D
60000
F0
Y Y Y Y
40783
0x030E
60000
F0
Y Y Y Y
40784
0x030F
Timer 19 Type
FC141
Y Y Y Y
40785
0x0310
60000
F0
Y Y Y Y
40786
0x0311
60000
F0
Y Y Y Y
40787
0x0312
Timer 20 Type
FC141
Y Y Y Y
40788
0x0313
60000
F0
Y Y Y Y
40789
0x0314
60000
F0
Y Y Y Y
40790
0x0315
Timer 21 Type
FC141
Y Y Y Y
40791
0x0316
60000
F0
Y Y Y Y
40792
0x0317
60000
F0
Y Y Y Y
0x0318
Timer 22 Type
FC141
Y Y Y Y
Timer 19
Timer 20
Timer 21
Timer 22
40793
11-67
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
40794
0x0319
60000
F0
Y Y Y Y
40795
0x031A
60000
F0
Y Y Y Y
40796
0x031B
Timer 23 Type
FC141
Y Y Y Y
40797
0x031C
60000
F0
Y Y Y Y
40798
0x031D
60000
F0
Y Y Y Y
Timer 23
Timer 24
40799
0x031E
Timer 24 Type
FC141
Y Y Y Y
40800
0x031F
60000
F0
Y Y Y Y
40801
0x0320
60000
F0
Y Y Y Y
40802
0x0321
Timer 25 Type
FC141
Y Y Y Y
40803
0x0322
60000
F0
Y Y Y Y
40804
0x0323
60000
F0
Y Y Y Y
40805
0x0324
Timer 26 Type
FC141
Y Y Y Y
40806
0x0325
60000
F0
Y Y Y Y
40807
0x0326
60000
F0
Y Y Y Y
40808
0x0327
Timer 27 Type
FC141
Y Y Y Y
40809
0x0328
60000
F0
Y Y Y Y
40810
0x0329
60000
F0
Y Y Y Y
40811
0x032A
Timer 28 Type
FC141
Y Y Y Y
40812
0x032B
60000
F0
Y Y Y Y
40813
0x032C
60000
F0
Y Y Y Y
40814
0x032D
Timer 29 Type
FC141
Y Y Y Y
40815
0x032E
60000
F0
Y Y Y Y
40816
0x032F
60000
F0
Y Y Y Y
40817
0x0330
Timer 30 Type
FC141
Y Y Y Y
40818
0x0331
60000
F0
Y Y Y Y
40819
0x0332
60000
F0
Y Y Y Y
40820
0x0333
Timer 31 Type
FC141
Y Y Y Y
40821
0x0334
60000
F0
Y Y Y Y
40822
0x0335
60000
F0
Y Y Y Y
40823
0x0336
Timer 32 Type
FC141
Y Y Y Y
40824
0x0337
60000
F0
Y Y Y Y
40825
0x0338
60000
F0
Y Y Y Y
Timer 25
Timer 26
Timer 27
Timer 28
Timer 29
Timer 30
Timer 31
Timer 32
Non-Volatile Latch 1
40840
0x0347
NV Latch 1 Name
65535
F60_26
NV Latch 1 13
Y Y Y Y
40853
0x0354
NV Latch 1 Function
FC126
Y Y Y Y
11-68
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
40854
0x0355
NV Latch 1 Type
FC271
40855
0x0356
NV Latch 1 Set
0xFFFFFFFF
FC142
Y Y Y Y
40857
0x0358
NV Latch 1 Reset
0xFFFFFFFF
FC142
Y Y Y Y
40859
0x035A
NV Latch 1 Events
FC126
Y Y Y Y
40860
0x035B
NV Latch 1 Targets
FC101
Y Y Y Y
Y Y Y Y
Non-Volatile Latch 2
40861
0x035C
NV Latch 2 Name
65535
F60_26
NV Latch 2 13
Y Y Y Y
40874
0x0369
NV Latch 2 Function
FC126
Y Y Y Y
40875
0x036A
NV Latch 2 Type
FC271
Y Y Y Y
40876
0x036B
NV Latch 2 Set
0xFFFFFFFF
FC142
Y Y Y Y
40878
0x036D
NV Latch 2 Reset
0xFFFFFFFF
FC142
Y Y Y Y
40880
0x036F
NV Latch 2 Events
FC126
Y Y Y Y
40881
0x0370
NV Latch 2 Targets
FC101
Y Y Y Y
Non-Volatile Latch 3
40882
0x0371
NV Latch 3 Name
65535
F60_26
NV Latch 3 13
Y Y Y Y
40895
0x037E
NV Latch 3 Function
FC126
Y Y Y Y
40896
0x037F
NV Latch 3 Type
FC271
Y Y Y Y
40897
0x0380
NV Latch 3 Set
0xFFFFFFFF
FC142
Y Y Y Y
40899
0x0382
NV Latch 3 Reset
0xFFFFFFFF
FC142
Y Y Y Y
40901
0x0384
NV Latch 3 Events
FC126
Y Y Y Y
40902
0x0385
NV Latch 3 Targets
FC101
Y Y Y Y
Non-Volatile Latch 4
40903
0x0386
NV Latch 4 Name
65535
F60_26
NV Latch 4 13
Y Y Y Y
40916
0x0393
NV Latch 4 Function
FC126
Y Y Y Y
40917
0x0394
NV Latch 4 Type
FC271
Y Y Y Y
40918
0x0395
NV Latch 4 Set
0xFFFFFFFF
FC142
Y Y Y Y
40920
0x0397
NV Latch 4 Reset
0xFFFFFFFF
FC142
Y Y Y Y
40922
0x0399
NV Latch 4 Events
FC126
Y Y Y Y
40923
0x039A
NV Latch 4 Targets
FC101
Y Y Y Y
Non-Volatile Latch 5
40924
0x039B
NV Latch 5 Name
65535
F60_26
NV Latch 5 13
Y Y Y Y
40937
0x03A8
NV Latch 5 Function
FC126
Y Y Y Y
40938
0x03A9
NV Latch 5 Type
FC271
Y Y Y Y
40939
0x03AA
NV Latch 5 Set
0xFFFFFFFF
FC142
Y Y Y Y
40941
0x03AC
NV Latch 5 Reset
0xFFFFFFFF
FC142
Y Y Y Y
40943
0x03AE
NV Latch 5 Events
FC126
Y Y Y Y
40944
0x03AF
NV Latch 5 Targets
FC101
Y Y Y Y
Non-Volatile Latch 6
40945
0x03B0
65535
F60_26
NV Latch 6 13
Y Y Y Y
40958
NV Latch 6 Name
FC126
Y Y Y Y
40959
0x03BE
NV Latch 6 Type
FC271
Y Y Y Y
40960
0x03BF
NV Latch 6 Set
0xFFFFFFFF
FC142
Y Y Y Y
40962
0x03C1
NV Latch 6 Reset
0xFFFFFFFF
FC142
Y Y Y Y
40964
0x03C3
NV Latch 6 Events
FC126
Y Y Y Y
40965
0x03C4
NV Latch 6 Targets
FC101
Y Y Y Y
11-69
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
Non-Volatile Latch 7
40966
0x03C5
NV Latch 7 Name
65535
F60_26
NV Latch 7 13
Y Y Y Y
40979
0x03D2
NV Latch 7 Function
FC126
Y Y Y Y
40980
0x03D3
NV Latch 7 Type
FC271
Y Y Y Y
40981
0x03D4
NV Latch 7 Set
0xFFFFFFFF
FC142
Y Y Y Y
40983
0x03D6
NV Latch 7 Reset
0xFFFFFFFF
FC142
Y Y Y Y
40985
0x03D8
NV Latch 7 Events
FC126
Y Y Y Y
40986
0x03D9
NV Latch 7 Targets
FC101
Y Y Y Y
Non-Volatile Latch 8
40987
65535
F60_26
NV Latch 8 13
Y Y Y Y
41000
0x03E7
NV Latch 8 Function
FC126
Y Y Y Y
41001
0x03E8
NV Latch 8 Type
FC271
Y Y Y Y
41002
0x03E9
NV Latch 8 Set
0xFFFFFFFF
FC142
Y Y Y Y
41004
0x03EB
NV Latch 8 Reset
0xFFFFFFFF
FC142
Y Y Y Y
41006
0x03ED
NV Latch 8 Events
FC126
Y Y Y Y
41007
0x03EE
NV Latch 8 Targets
FC101
Y Y Y Y
Non-Volatile Latch 9
41008
0x03EF
NV Latch 9 Name
65535
F60_26
NV Latch 9 13
Y Y Y Y
41021
0x03FC
NV Latch 9 Function
FC126
Y Y Y Y
41022
0x03FD
NV Latch 9 Type
FC271
Y Y Y Y
41023
0x03FE
NV Latch 9 Set
0xFFFFFFFF
FC142
Y Y Y Y
41025
0x0400
NV Latch 9 Reset
0xFFFFFFFF
FC142
Y Y Y Y
41027
0x0402
NV Latch 9 Events
FC126
Y Y Y Y
41028
0x0403
NV Latch 9 Targets
FC101
Y Y Y Y
Non-Volatile Latch 10
41029
0x0404
NV Latch 10 Name
65535
F60_26
NV Latch
10
13
Y Y Y Y
41042
0x0411
NV Latch 10 Function
FC126
Y Y Y Y
41043
0x0412
NV Latch 10 Type
FC271
Y Y Y Y
41044
0x0413
NV Latch 10 Set
0xFFFFFFFF
FC142
Y Y Y Y
41046
0x0415
NV Latch 10 Reset
0xFFFFFFFF
FC142
Y Y Y Y
41048
0x0417
NV Latch 10 Events
FC126
Y Y Y Y
41049
0x0418
NV Latch 10 Targets
FC101
Y Y Y Y
Non-Volatile Latch 11
41050
0x0419
NV Latch 11 Name
65535
F60_26
NV Latch
11
13
Y Y Y Y
41063
0x0426
NV Latch 11 Function
FC126
Y Y Y Y
41064
0x0427
NV Latch 11 Type
FC271
Y Y Y Y
41065
0x0428
NV Latch 11 Set
0xFFFFFFFF
FC142
Y Y Y Y
41067
0x042A
NV Latch 11 Reset
0xFFFFFFFF
FC142
Y Y Y Y
41069
0x042C
NV Latch 11 Events
FC126
Y Y Y Y
41070
0x042D
NV Latch 11 Targets
FC101
Y Y Y Y
Non-Volatile Latch 12
41071
0x042E
NV Latch 12 Name
65535
F60_26
NV Latch
12
13
Y Y Y Y
41084
0x043B
NV Latch 12 Function
FC126
Y Y Y Y
11-70
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
41085
FC271
0x043C
NV Latch 12 Type
Y Y Y Y
41086
0x043D
NV Latch 12 Set
0xFFFFFFFF
FC142
Y Y Y Y
41088
0x043F
NV Latch 12 Reset
0xFFFFFFFF
FC142
Y Y Y Y
41090
0x0441
NV Latch 12 Events
FC126
Y Y Y Y
41091
0x0442
NV Latch 12 Targets
FC101
Y Y Y Y
65535
F60_26
NV Latch
13
13
Y Y Y Y
Non-Volatile Latch 13
41092
0x0443
NV Latch 13 Name
41105
0x0450
NV Latch 13 Function
FC126
Y Y Y Y
41106
0x0451
NV Latch 13 Type
FC271
Y Y Y Y
41107
0x0452
NV Latch 13 Set
0xFFFFFFFF
FC142
Y Y Y Y
41109
0x0454
NV Latch 13 Reset
0xFFFFFFFF
FC142
Y Y Y Y
41111
0x0456
NV Latch 13 Events
FC126
Y Y Y Y
41112
0x0457
NV Latch 13 Targets
FC101
Y Y Y Y
Non-Volatile Latch 14
41113
0x0458
NV Latch 14 Name
65535
F60_26
NV Latch
14
13
Y Y Y Y
41126
0x0465
NV Latch 14 Function
FC126
Y Y Y Y
41127
0x0466
NV Latch 14 Type
FC271
Y Y Y Y
41128
0x0467
NV Latch 14 Set
0xFFFFFFFF
FC142
Y Y Y Y
41130
0x0469
NV Latch 14 Reset
0xFFFFFFFF
FC142
Y Y Y Y
41132
0x046B
NV Latch 14 Events
FC126
Y Y Y Y
41133
0x046C
NV Latch 14 Targets
FC101
Y Y Y Y
Non-Volatile Latch 15
41134
0x046D
NV Latch 15 Name
65535
F60_26
NV Latch
15
13
Y Y Y Y
41147
0x047A
NV Latch 15 Function
FC126
Y Y Y Y
41148
0x047B
NV Latch 15 Type
FC271
Y Y Y Y
41149
0x047C
NV Latch 15 Set
0xFFFFFFFF
FC142
Y Y Y Y
41151
0x047E
NV Latch 15 Reset
0xFFFFFFFF
FC142
Y Y Y Y
41153
0x0480
NV Latch 15 Events
FC126
Y Y Y Y
41154
0x0481
NV Latch 15 Targets
FC101
Y Y Y Y
Non-Volatile Latch 16
41155
0x0482
NV Latch 16 Name
65535
F60_26
NV Latch
16
13
Y Y Y Y
41168
0x048F
NV Latch 16 Function
FC126
Y Y Y Y
41169
0x0490
NV Latch 16 Type
FC271
Y Y Y Y
41170
0x0491
NV Latch 16 Set
0xFFFFFFFF
FC142
Y Y Y Y
41172
0x0493
NV Latch 16 Reset
0xFFFFFFFF
FC142
Y Y Y Y
41174
0x0495
NV Latch 16 Events
FC126
Y Y Y Y
41175
0x0496
NV Latch 16 Targets
FC101
Y Y Y Y
0x04A5
FC126A
Y Y Y Y
41191
0x04A6
FC126A
Y Y Y Y
41192
0x04A7
FC126A
Y Y Y Y
41193
0x04A8
FC126A
Y Y Y Y
41194
0x04A9
FC126A
Y Y Y Y
11-71
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
41195
0x04AA
FC126A
Y Y Y Y
41196
0x04AB
FC126A
Y Y Y Y
41197
0x04AC
FC126A
Y Y Y Y
41198
FC126A
Y Y Y Y
41199
0x04AE
FC126A
Y Y Y Y
41200
0x04AF
FC126A
Y Y Y Y
41201
0x04B0
FC126A
Y Y Y Y
41202
0x04B1
FC126A
Y Y Y Y
41203
0x04B2
FC126A
Y Y Y Y
41204
0x04B3
FC126A
Y Y Y Y
41205
0x04B4
FC126A
Y Y Y Y
41206
0x04B5
FC126A
Y Y Y Y
41207
0x04B6
FC126A
Y Y Y Y
41208
0x04B7
FC126A
Y Y Y Y
41209
0x04B8
FC126A
Y Y Y Y
41210
0x04B9
FC126A
Y Y Y Y
41211
0x04BA
FC126A
Y Y Y Y
41212
0x04BB
FC126A
Y Y Y Y
41213
0x04BC
FC126A
Y Y Y Y
41214
FC126A
Y Y Y Y
41215
0x04BE
FC126A
Y Y Y Y
41216
0x04BF
FC126A
Y Y Y Y
41217
0x04C0
FC126A
Y Y Y Y
41218
0x04C1
FC126A
Y Y Y Y
41219
0x04C2
FC126A
Y Y Y Y
41220
0x04C3
FC126A
Y Y Y Y
41221
0x04C4
FC126A
Y Y Y Y
0x0531
Parameter 1
0xFFFFFFFF
FC142
Y Y Y Y
41332
0x0533
Parameter 2
0xFFFFFFFF
FC142
Y Y Y Y
41334
0x0535
Parameter 3
0xFFFFFFFF
FC142
Y Y Y Y
41336
0x0537
Parameter 4
0xFFFFFFFF
FC142
Y Y Y Y
41338
0x0539
Parameter 5
0xFFFFFFFF
FC142
Y Y Y Y
41340
0x053B
Parameter 6
0xFFFFFFFF
FC142
Y Y Y Y
41342
0x053D
Parameter 7
0xFFFFFFFF
FC142
Y Y Y Y
41344
0x053F
Parameter 8
0xFFFFFFFF
FC142
Y Y Y Y
41346
0x0541
Parameter 9
0xFFFFFFFF
FC142
Y Y Y Y
41348
0x0543
Parameter 10
0xFFFFFFFF
FC142
Y Y Y Y
41350
0x0545
Parameter 11
0xFFFFFFFF
FC142
Y Y Y Y
41352
0x0547
Parameter 12
0xFFFFFFFF
FC142
Y Y Y Y
41354
0x0549
Parameter 13
0xFFFFFFFF
FC142
Y Y Y Y
41356
0x054B
Parameter 14
0xFFFFFFFF
FC142
Y Y Y Y
41358
0x054D
Parameter 15
0xFFFFFFFF
FC142
Y Y Y Y
41360
0x054F
Parameter 16
0xFFFFFFFF
FC142
Y Y Y Y
41362
0x0551
Parameter 17
0xFFFFFFFF
FC142
Y Y Y Y
11-72
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
41364
0x0553
Parameter 18
0xFFFFFFFF
FC142
Y Y Y Y
41366
0x0555
Parameter 19
0xFFFFFFFF
FC142
Y Y Y Y
41368
0x0557
Parameter 20
0xFFFFFFFF
FC142
Y Y Y Y
41370
0x0559
Parameter 21
0xFFFFFFFF
FC142
Y Y Y Y
41372
0x055B
Parameter 22
0xFFFFFFFF
FC142
Y Y Y Y
41374
0x055D
Parameter 23
0xFFFFFFFF
FC142
Y Y Y Y
41376
0x055F
Parameter 24
0xFFFFFFFF
FC142
Y Y Y Y
41378
0x0561
Parameter 25
0xFFFFFFFF
FC142
Y Y Y Y
41380
0x0563
Parameter 26
0xFFFFFFFF
FC142
Y Y Y Y
41382
0x0565
Parameter 27
0xFFFFFFFF
FC142
Y Y Y Y
41384
0x0567
Parameter 28
0xFFFFFFFF
FC142
Y Y Y Y
41386
0x0569
Parameter 29
0xFFFFFFFF
FC142
Y Y Y Y
41388
0x056B
Parameter 30
0xFFFFFFFF
FC142
Y Y Y Y
41390
0x056D
Parameter 31
0xFFFFFFFF
FC142
Y Y Y Y
41392
0x056F
Parameter 32
0xFFFFFFFF
FC142
Y Y Y Y
41394
0x0571
Parameter 33
0xFFFFFFFF
FC142
Y Y Y Y
41396
0x0573
Parameter 34
0xFFFFFFFF
FC142
Y Y Y Y
41398
0x0575
Parameter 35
0xFFFFFFFF
FC142
Y Y Y Y
41400
0x0577
Parameter 36
0xFFFFFFFF
FC142
Y Y Y Y
41402
0x0579
Parameter 37
0xFFFFFFFF
FC142
Y Y Y Y
41404
0x057B
Parameter 38
0xFFFFFFFF
FC142
Y Y Y Y
41406
0x057D
Parameter 39
0xFFFFFFFF
FC142
Y Y Y Y
41408
0x057F
Parameter 40
0xFFFFFFFF
FC142
Y Y Y Y
41410
0x0581
Parameter 41
0xFFFFFFFF
FC142
Y Y Y Y
41412
0x0583
Parameter 42
0xFFFFFFFF
FC142
Y Y Y Y
41414
0x0585
Parameter 43
0xFFFFFFFF
FC142
Y Y Y Y
41416
0x0587
Parameter 44
0xFFFFFFFF
FC142
Y Y Y Y
41418
0x0589
Parameter 45
0xFFFFFFFF
FC142
Y Y Y Y
41420
0x058B
Parameter 46
0xFFFFFFFF
FC142
Y Y Y Y
41422
0x058D
Parameter 47
0xFFFFFFFF
FC142
Y Y Y Y
41424
0x058F
Parameter 48
0xFFFFFFFF
FC142
Y Y Y Y
41426
0x0591
Parameter 49
0xFFFFFFFF
FC142
Y Y Y Y
41428
0x0593
Parameter 50
0xFFFFFFFF
FC142
Y Y Y Y
41430
0x0595
Parameter 51
0xFFFFFFFF
FC142
Y Y Y Y
41432
0x0597
Parameter 52
0xFFFFFFFF
FC142
Y Y Y Y
41434
0x0599
Parameter 53
0xFFFFFFFF
FC142
Y Y Y Y
41436
0x059B
Parameter 54
0xFFFFFFFF
FC142
Y Y Y Y
41438
0x059D
Parameter 55
0xFFFFFFFF
FC142
Y Y Y Y
41440
0x059F
Parameter 56
0xFFFFFFFF
FC142
Y Y Y Y
41442
0x05A1
Parameter 57
0xFFFFFFFF
FC142
Y Y Y Y
41444
0x05A3
Parameter 58
0xFFFFFFFF
FC142
Y Y Y Y
41446
0x05A5
Parameter 59
0xFFFFFFFF
FC142
Y Y Y Y
41448
0x05A7
Parameter 60
0xFFFFFFFF
FC142
Y Y Y Y
41450
0x05A9
Parameter 61
0xFFFFFFFF
FC142
Y Y Y Y
41452
0x05AB
Parameter 62
0xFFFFFFFF
FC142
Y Y Y Y
11-73
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
41454
0x05AD Parameter 63
0xFFFFFFFF
FC142
Y Y Y Y
41456
0x05AF
Parameter 64
0xFFFFFFFF
FC142
Y Y Y Y
41458
0x05B1
Parameter 65
0xFFFFFFFF
FC142
Y Y Y Y
41460
0x05B3
Parameter 66
0xFFFFFFFF
FC142
Y Y Y Y
41462
0x05B5
Parameter 67
0xFFFFFFFF
FC142
Y Y Y Y
41464
0x05B7
Parameter 68
0xFFFFFFFF
FC142
Y Y Y Y
41466
0x05B9
Parameter 69
0xFFFFFFFF
FC142
Y Y Y Y
41468
0x05BB
Parameter 70
0xFFFFFFFF
FC142
Y Y Y Y
41470
0x05BD Parameter 71
0xFFFFFFFF
FC142
Y Y Y Y
41472
0x05BF
Parameter 72
0xFFFFFFFF
FC142
Y Y Y Y
41474
0x05C1
Parameter 73
0xFFFFFFFF
FC142
Y Y Y Y
41476
0x05C3
Parameter 74
0xFFFFFFFF
FC142
Y Y Y Y
41478
0x05C5
Parameter 75
0xFFFFFFFF
FC142
Y Y Y Y
41480
0x05C7
Parameter 76
0xFFFFFFFF
FC142
Y Y Y Y
41482
0x05C9
Parameter 77
0xFFFFFFFF
FC142
Y Y Y Y
41484
0x05CB
Parameter 78
0xFFFFFFFF
FC142
Y Y Y Y
41486
0x05CD Parameter 79
0xFFFFFFFF
FC142
Y Y Y Y
41488
0x05CF
Parameter 80
0xFFFFFFFF
FC142
Y Y Y Y
41490
0x05D1
Parameter 81
0xFFFFFFFF
FC142
Y Y Y Y
41492
0x05D3
Parameter 82
0xFFFFFFFF
FC142
Y Y Y Y
41494
0x05D5
Parameter 83
0xFFFFFFFF
FC142
Y Y Y Y
41496
0x05D7
Parameter 84
0xFFFFFFFF
FC142
Y Y Y Y
41498
0x05D9
Parameter 85
0xFFFFFFFF
FC142
Y Y Y Y
41500
0x05DB Parameter 86
0xFFFFFFFF
FC142
Y Y Y Y
41502
0x05DD Parameter 87
0xFFFFFFFF
FC142
Y Y Y Y
41504
0x05DF
Parameter 88
0xFFFFFFFF
FC142
Y Y Y Y
41506
0x05E1
Parameter 89
0xFFFFFFFF
FC142
Y Y Y Y
41508
0x05E3
Parameter 90
0xFFFFFFFF
FC142
Y Y Y Y
41510
0x05E5
Parameter 91
0xFFFFFFFF
FC142
Y Y Y Y
41512
0x05E7
Parameter 92
0xFFFFFFFF
FC142
Y Y Y Y
41514
0x05E9
Parameter 93
0xFFFFFFFF
FC142
Y Y Y Y
41516
0x05EB
Parameter 94
0xFFFFFFFF
FC142
Y Y Y Y
41518
0x05ED
Parameter 95
0xFFFFFFFF
FC142
Y Y Y Y
41520
0x05EF
Parameter 96
0xFFFFFFFF
FC142
Y Y Y Y
41522
0x05F1
Parameter 97
0xFFFFFFFF
FC142
Y Y Y Y
41524
0x05F3
Parameter 98
0xFFFFFFFF
FC142
Y Y Y Y
41526
0x05F5
Parameter 99
0xFFFFFFFF
FC142
Y Y Y Y
41528
0x05F7
Parameter 100
0xFFFFFFFF
FC142
Y Y Y Y
41530
0x05F9
Parameter 101
0xFFFFFFFF
FC142
Y Y Y Y
41532
0x05FB
Parameter 102
0xFFFFFFFF
FC142
Y Y Y Y
41534
0x05FD
Parameter 103
0xFFFFFFFF
FC142
Y Y Y Y
41536
0x05FF
Parameter 104
0xFFFFFFFF
FC142
Y Y Y Y
41538
0x0601
Parameter 105
0xFFFFFFFF
FC142
Y Y Y Y
41540
0x0603
Parameter 106
0xFFFFFFFF
FC142
Y Y Y Y
41542
0x0605
Parameter 107
0xFFFFFFFF
FC142
Y Y Y Y
11-74
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
41544
0x0607
Parameter 108
0xFFFFFFFF
FC142
Y Y Y Y
41546
0x0609
Parameter 109
0xFFFFFFFF
FC142
Y Y Y Y
41548
0x060B
Parameter 110
0xFFFFFFFF
FC142
Y Y Y Y
41550
0x060D
Parameter 111
0xFFFFFFFF
FC142
Y Y Y Y
41552
0x060F
Parameter 112
0xFFFFFFFF
FC142
Y Y Y Y
41554
0x0611
Parameter 113
0xFFFFFFFF
FC142
Y Y Y Y
41556
0x0613
Parameter 114
0xFFFFFFFF
FC142
Y Y Y Y
41558
0x0615
Parameter 115
0xFFFFFFFF
FC142
Y Y Y Y
41560
0x0617
Parameter 116
0xFFFFFFFF
FC142
Y Y Y Y
41562
0x0619
Parameter 117
0xFFFFFFFF
FC142
Y Y Y Y
41564
0x061B
Parameter 118
0xFFFFFFFF
FC142
Y Y Y Y
41566
0x061D
Parameter 119
0xFFFFFFFF
FC142
Y Y Y Y
41568
0x061F
Parameter 120
0xFFFFFFFF
FC142
Y Y Y Y
41570
0x0621
Parameter 121
0xFFFFFFFF
FC142
Y Y Y Y
41572
0x0623
Parameter 122
0xFFFFFFFF
FC142
Y Y Y Y
41574
0x0625
Parameter 123
0xFFFFFFFF
FC142
Y Y Y Y
41576
0x0627
Parameter 124
0xFFFFFFFF
FC142
Y Y Y Y
41578
0x0629
Parameter 125
0xFFFFFFFF
FC142
Y Y Y Y
41580
0x062B
Parameter 126
0xFFFFFFFF
FC142
Y Y Y Y
41582
0x062D
Parameter 127
0xFFFFFFFF
FC142
Y Y Y Y
41584
0x062F
Parameter 128
0xFFFFFFFF
FC142
Y Y Y Y
41586
0x0631
Parameter 129
0xFFFFFFFF
FC142
Y Y Y Y
41588
0x0633
Parameter 130
0xFFFFFFFF
FC142
Y Y Y Y
41590
0x0635
Parameter 131
0xFFFFFFFF
FC142
Y Y Y Y
41592
0x0637
Parameter 132
0xFFFFFFFF
FC142
Y Y Y Y
41594
0x0639
Parameter 133
0xFFFFFFFF
FC142
Y Y Y Y
41596
0x063B
Parameter 134
0xFFFFFFFF
FC142
Y Y Y Y
41598
0x063D
Parameter 135
0xFFFFFFFF
FC142
Y Y Y Y
41600
0x063F
Parameter 136
0xFFFFFFFF
FC142
Y Y Y Y
41602
0x0641
Parameter 137
0xFFFFFFFF
FC142
Y Y Y Y
41604
0x0643
Parameter 138
0xFFFFFFFF
FC142
Y Y Y Y
41606
0x0645
Parameter 139
0xFFFFFFFF
FC142
Y Y Y Y
41608
0x0647
Parameter 140
0xFFFFFFFF
FC142
Y Y Y Y
41610
0x0649
Parameter 141
0xFFFFFFFF
FC142
Y Y Y Y
41612
0x064B
Parameter 142
0xFFFFFFFF
FC142
Y Y Y Y
41614
0x064D
Parameter 143
0xFFFFFFFF
FC142
Y Y Y Y
41616
0x064F
Parameter 144
0xFFFFFFFF
FC142
Y Y Y Y
41618
0x0651
Parameter 145
0xFFFFFFFF
FC142
Y Y Y Y
41620
0x0653
Parameter 146
0xFFFFFFFF
FC142
Y Y Y Y
41622
0x0655
Parameter 147
0xFFFFFFFF
FC142
Y Y Y Y
41624
0x0657
Parameter 148
0xFFFFFFFF
FC142
Y Y Y Y
41626
0x0659
Parameter 149
0xFFFFFFFF
FC142
Y Y Y Y
41628
0x065B
Parameter 150
0xFFFFFFFF
FC142
Y Y Y Y
41630
0x065D
Parameter 151
0xFFFFFFFF
FC142
Y Y Y Y
41632
0x065F
Parameter 152
0xFFFFFFFF
FC142
Y Y Y Y
11-75
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
41634
0x0661
Parameter 153
0xFFFFFFFF
FC142
Y Y Y Y
41636
0x0663
Parameter 154
0xFFFFFFFF
FC142
Y Y Y Y
41638
0x0665
Parameter 155
0xFFFFFFFF
FC142
Y Y Y Y
41640
0x0667
Parameter 156
0xFFFFFFFF
FC142
Y Y Y Y
41642
0x0669
Parameter 157
0xFFFFFFFF
FC142
Y Y Y Y
41644
0x066B
Parameter 158
0xFFFFFFFF
FC142
Y Y Y Y
41646
0x066D
Parameter 159
0xFFFFFFFF
FC142
Y Y Y Y
41648
0x066F
Parameter 160
0xFFFFFFFF
FC142
Y Y Y Y
41650
0x0671
Parameter 161
0xFFFFFFFF
FC142
Y Y Y Y
41652
0x0673
Parameter 162
0xFFFFFFFF
FC142
Y Y Y Y
41654
0x0675
Parameter 163
0xFFFFFFFF
FC142
Y Y Y Y
41656
0x0677
Parameter 164
0xFFFFFFFF
FC142
Y Y Y Y
41658
0x0679
Parameter 165
0xFFFFFFFF
FC142
Y Y Y Y
41660
0x067B
Parameter 166
0xFFFFFFFF
FC142
Y Y Y Y
41662
0x067D
Parameter 167
0xFFFFFFFF
FC142
Y Y Y Y
41664
0x067F
Parameter 168
0xFFFFFFFF
FC142
Y Y Y Y
41666
0x0681
Parameter 169
0xFFFFFFFF
FC142
Y Y Y Y
41668
0x0683
Parameter 170
0xFFFFFFFF
FC142
Y Y Y Y
41670
0x0685
Parameter 171
0xFFFFFFFF
FC142
Y Y Y Y
41672
0x0687
Parameter 172
0xFFFFFFFF
FC142
Y Y Y Y
41674
0x0689
Parameter 173
0xFFFFFFFF
FC142
Y Y Y Y
41676
0x068B
Parameter 174
0xFFFFFFFF
FC142
Y Y Y Y
41678
0x068D
Parameter 175
0xFFFFFFFF
FC142
Y Y Y Y
41680
0x068F
Parameter 176
0xFFFFFFFF
FC142
Y Y Y Y
41682
0x0691
Parameter 177
0xFFFFFFFF
FC142
Y Y Y Y
41684
0x0693
Parameter 178
0xFFFFFFFF
FC142
Y Y Y Y
41686
0x0695
Parameter 179
0xFFFFFFFF
FC142
Y Y Y Y
41688
0x0697
Parameter 180
0xFFFFFFFF
FC142
Y Y Y Y
41690
0x0699
Parameter 181
0xFFFFFFFF
FC142
Y Y Y Y
41692
0x069B
Parameter 182
0xFFFFFFFF
FC142
Y Y Y Y
41694
0x069D
Parameter 183
0xFFFFFFFF
FC142
Y Y Y Y
41696
0x069F
Parameter 184
0xFFFFFFFF
FC142
Y Y Y Y
41698
0x06A1
Parameter 185
0xFFFFFFFF
FC142
Y Y Y Y
41700
0x06A3
Parameter 186
0xFFFFFFFF
FC142
Y Y Y Y
41702
0x06A5
Parameter 187
0xFFFFFFFF
FC142
Y Y Y Y
41704
0x06A7
Parameter 188
0xFFFFFFFF
FC142
Y Y Y Y
41706
0x06A9
Parameter 189
0xFFFFFFFF
FC142
Y Y Y Y
41708
0x06AB
Parameter 190
0xFFFFFFFF
FC142
Y Y Y Y
41710
0xFFFFFFFF
FC142
Y Y Y Y
41712
0x06AF
Parameter 192
0xFFFFFFFF
FC142
Y Y Y Y
41714
0x06B1
Parameter 193
0xFFFFFFFF
FC142
Y Y Y Y
41716
0x06B3
Parameter 194
0xFFFFFFFF
FC142
Y Y Y Y
41718
0x06B5
Parameter 195
0xFFFFFFFF
FC142
Y Y Y Y
41720
0x06B7
Parameter 196
0xFFFFFFFF
FC142
Y Y Y Y
41722
0x06B9
Parameter 197
0xFFFFFFFF
FC142
Y Y Y Y
11-76
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
41724
0x06BB
0xFFFFFFFF
FC142
41726
0xFFFFFFFF
FC142
Y Y Y Y
41728
0x06BF
Parameter 200
0xFFFFFFFF
FC142
Y Y Y Y
41730
0x06C1
Parameter 201
0xFFFFFFFF
FC142
Y Y Y Y
41732
0x06C3
Parameter 202
0xFFFFFFFF
FC142
Y Y Y Y
41734
0x06C5
Parameter 203
0xFFFFFFFF
FC142
Y Y Y Y
41736
0x06C7
Parameter 204
0xFFFFFFFF
FC142
Y Y Y Y
41738
0x06C9
Parameter 205
0xFFFFFFFF
FC142
Y Y Y Y
41740
0x06CB
Parameter 206
0xFFFFFFFF
FC142
Y Y Y Y
41742
0xFFFFFFFF
FC142
Y Y Y Y
41744
0x06CF
Parameter 208
0xFFFFFFFF
FC142
Y Y Y Y
41746
0x06D1
Parameter 209
0xFFFFFFFF
FC142
Y Y Y Y
41748
0x06D3
Parameter 210
0xFFFFFFFF
FC142
Y Y Y Y
41750
0x06D5
Parameter 211
0xFFFFFFFF
FC142
Y Y Y Y
41752
0x06D7
Parameter 212
0xFFFFFFFF
FC142
Y Y Y Y
41754
0x06D9
Parameter 213
0xFFFFFFFF
FC142
Y Y Y Y
41756
0xFFFFFFFF
FC142
Y Y Y Y
41758
0xFFFFFFFF
FC142
Y Y Y Y
41760
0x06DF
Parameter 216
0xFFFFFFFF
FC142
Y Y Y Y
41762
0x06E1
Parameter 217
0xFFFFFFFF
FC142
Y Y Y Y
41764
0x06E3
Parameter 218
0xFFFFFFFF
FC142
Y Y Y Y
41766
0x06E5
Parameter 219
0xFFFFFFFF
FC142
Y Y Y Y
41768
0x06E7
Parameter 220
0xFFFFFFFF
FC142
Y Y Y Y
41770
0x06E9
Parameter 221
0xFFFFFFFF
FC142
Y Y Y Y
41772
0x06EB
Parameter 222
0xFFFFFFFF
FC142
Y Y Y Y
41774
0x06ED
Parameter 223
0xFFFFFFFF
FC142
Y Y Y Y
41776
0x06EF
Parameter 224
0xFFFFFFFF
FC142
Y Y Y Y
41778
0x06F1
Parameter 225
0xFFFFFFFF
FC142
Y Y Y Y
41780
0x06F3
Parameter 226
0xFFFFFFFF
FC142
Y Y Y Y
41782
0x06F5
Parameter 227
0xFFFFFFFF
FC142
Y Y Y Y
41784
0x06F7
Parameter 228
0xFFFFFFFF
FC142
Y Y Y Y
41786
0x06F9
Parameter 229
0xFFFFFFFF
FC142
Y Y Y Y
41788
0x06FB
Parameter 230
0xFFFFFFFF
FC142
Y Y Y Y
41790
0x06FD
Parameter 231
0xFFFFFFFF
FC142
Y Y Y Y
41792
0x06FF
Parameter 232
0xFFFFFFFF
FC142
Y Y Y Y
41794
0x0701
Parameter 233
0xFFFFFFFF
FC142
Y Y Y Y
41796
0x0703
Parameter 234
0xFFFFFFFF
FC142
Y Y Y Y
41798
0x0705
Parameter 235
0xFFFFFFFF
FC142
Y Y Y Y
41800
0x0707
Parameter 236
0xFFFFFFFF
FC142
Y Y Y Y
41802
0x0709
Parameter 237
0xFFFFFFFF
FC142
Y Y Y Y
41804
0x070B
Parameter 238
0xFFFFFFFF
FC142
Y Y Y Y
41806
0x070D
Parameter 239
0xFFFFFFFF
FC142
Y Y Y Y
41808
0x070F
Parameter 240
0xFFFFFFFF
FC142
Y Y Y Y
41810
0x0711
Parameter 241
0xFFFFFFFF
FC142
Y Y Y Y
41812
0x0713
Parameter 242
0xFFFFFFFF
FC142
Y Y Y Y
Parameter 198
Y Y Y Y
11-77
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
41814
0x0715
Parameter 243
0xFFFFFFFF
FC142
Y Y Y Y
41816
0x0717
Parameter 244
0xFFFFFFFF
FC142
Y Y Y Y
41818
0x0719
Parameter 245
0xFFFFFFFF
FC142
Y Y Y Y
41820
0x071B
Parameter 246
0xFFFFFFFF
FC142
Y Y Y Y
41822
0x071D
Parameter 247
0xFFFFFFFF
FC142
Y Y Y Y
41824
0x071F
Parameter 248
0xFFFFFFFF
FC142
Y Y Y Y
41826
0x0721
Parameter 249
0xFFFFFFFF
FC142
Y Y Y Y
41828
0x0723
Parameter 250
0xFFFFFFFF
FC142
Y Y Y Y
41830
0x0725
Parameter 251
0xFFFFFFFF
FC142
Y Y Y Y
41832
0x0727
Parameter 252
0xFFFFFFFF
FC142
Y Y Y Y
41834
0x0729
Parameter 253
0xFFFFFFFF
FC142
Y Y Y Y
41836
0x072B
Parameter 254
0xFFFFFFFF
FC142
Y Y Y Y
41838
0x072D
Parameter 255
0xFFFFFFFF
FC142
Y Y Y Y
41840
0x072F
Parameter 256
0xFFFFFFFF
FC142
Y Y Y Y
FlexElement 1
41860
0x0743
Function
FC126
Y Y Y Y
41861
0x0744
Name
65535
F60_26
FlexEl 1
13
Y Y Y Y
41874
0x0751
Input 1 (+)
35903
FC273
Y Y Y Y
41875
0x0752
Input 2 (-)
35903
FC273
Y Y Y Y
41876
0x0753
FC378
Y Y Y Y
41877
0x0754
Operating Mode
FC379
Y Y Y Y
41878
0x0755
Operating Signal
Direction
FC275
Y Y Y Y
41879
0x0756
Pickup
-30000
30000
p.u.
F23
1000
Y Y Y Y
41880
0x0757
Hysteresis
500
F1
30
Y Y Y Y
41881
0x0758
FC141
Y Y Y Y
41882
0x0759
40
65535
F0
40
Y Y Y Y
41883
0x075A
Pickup Delay
6000000
F13
Y Y Y Y
41885
0x075C
Dropout Delay
6000000
F13
Y Y Y Y
41887
0x075E
Block
0xFFFFFFFF
FC142
Y Y Y Y
41889
0x0760
Relays
0xFFFFFFFF
FC198
Y Y Y Y
41891
0x0762
Events
FC126
Y Y Y Y
41892
0x0763
Targets
FC101
Y Y Y Y
FlexElement 2
41899
0x076A
Function
FC126
Y Y Y Y
41900
0x076B
Name
65535
F60_26
FlexEl 2
13
Y Y Y Y
41913
0x0778
Input 1 (+)
35903
FC273
Y Y Y Y
41914
0x0779
Input 2 (-)
35903
FC273
Y Y Y Y
41915
0x077A
FC378
Y Y Y Y
41916
0x077B
Operating Mode
FC379
Y Y Y Y
41917
0x077C
Operating Signal
Direction
FC275
Y Y Y Y
41918
0x077D
Pickup
-30000
30000
p.u.
F23
1000
Y Y Y Y
41919
0x077E
Hysteresis
500
F1
30
Y Y Y Y
41920
0x077F
FC141
Y Y Y Y
11-78
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
41921
40
65535
F0
40
0x0780
Y Y Y Y
41922
0x0781
Pickup Delay
6000000
F13
Y Y Y Y
41924
0x0783
Dropout Delay
6000000
F13
Y Y Y Y
41926
0x0785
Block
0xFFFFFFFF
FC142
Y Y Y Y
41928
0x0787
Relays
0xFFFFFFFF
FC198
Y Y Y Y
41930
0x0789
Events
FC126
Y Y Y Y
41931
0x078A
Targets
FC101
Y Y Y Y
Function
FC126
Y Y Y Y
FlexElement 3
41938
0x0791
41939
0x0792
Name
65535
F60_26
FlexEl 3
13
Y Y Y Y
41952
0x079F
Input 1 (+)
35903
FC273
Y Y Y Y
41953
0x07A0
Input 2 (-)
35903
FC273
Y Y Y Y
41954
0x07A1
FC378
Y Y Y Y
41955
0x07A2
Operating Mode
FC379
Y Y Y Y
41956
0x07A3
Operating Signal
Direction
FC275
Y Y Y Y
41957
0x07A4
Pickup
-30000
30000
p.u.
F23
1000
Y Y Y Y
41958
0x07A5
Hysteresis
500
F1
30
Y Y Y Y
41959
0x07A6
FC141
Y Y Y Y
41960
0x07A7
65535
F0
40
Y Y Y Y
41961
0x07A8
Pickup Delay
6000000
F13
Y Y Y Y
41963
0x07AA
Dropout Delay
6000000
F13
Y Y Y Y
41965
0x07AC
Block
0xFFFFFFFF
FC142
Y Y Y Y
41967
0x07AE
Relays
0xFFFFFFFF
FC198
Y Y Y Y
41969
0x07B0
Events
FC126
Y Y Y Y
41970
0x07B1
Targets
FC101
Y Y Y Y
40
FlexElement 4
41977
0x07B8
Function
FC126
Y Y Y Y
41978
0x07B9
Name
65535
F60_26
FlexEl 4
13
Y Y Y Y
41991
0x07C6
Input 1 (+)
35903
FC273
Y Y Y Y
41992
0x07C7
Input 2 (-)
35903
FC273
Y Y Y Y
41993
0x07C8
FC378
Y Y Y Y
41994
0x07C9
Operating Mode
FC379
Y Y Y Y
41995
0x07CA
Operating Signal
Direction
FC275
Y Y Y Y
41996
0x07CB
Pickup
-30000
30000
p.u.
F23
1000
Y Y Y Y
41997
0x07CC
Hysteresis
500
F1
30
Y Y Y Y
41998
FC141
Y Y Y Y
41999
0x07CE
65535
F0
40
Y Y Y Y
42000
0x07CF
Pickup Delay
6000000
F13
Y Y Y Y
42002
0x07D1
Dropout Delay
6000000
F13
Y Y Y Y
42004
0x07D3
Block
0xFFFFFFFF
FC142
Y Y Y Y
42006
0x07D5
Relays
0xFFFFFFFF
FC198
Y Y Y Y
42008
0x07D7
Events
FC126
Y Y Y Y
42009
0x07D8
Targets
FC101
Y Y Y Y
40
11-79
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
FlexElement 5
42016
0x07DF
Function
FC126
Y Y Y Y
42017
0x07E0
Name
65535
F60_26
FlexEl 5
13
Y Y Y Y
42030
0x07ED
Input 1 (+)
35903
FC273
Y Y Y Y
42031
0x07EE
Input 2 (-)
35903
FC273
Y Y Y Y
42032
0x07EF
FC378
Y Y Y Y
42033
0x07F0
Operating Mode
FC379
Y Y Y Y
42034
0x07F1
Operating Signal
Direction
FC275
Y Y Y Y
42035
0x07F2
Pickup
-30000
30000
p.u.
F23
1000
Y Y Y Y
42036
0x07F3
Hysteresis
500
42037
0x07F4
F1
30
Y Y Y Y
FC141
Y Y Y Y
42038
0x07F5
40
65535
F0
40
Y Y Y Y
42039
0x07F6
Pickup Delay
6000000
F13
Y Y Y Y
42041
0x07F8
Dropout Delay
6000000
F13
Y Y Y Y
42043
0x07FA
Block
0xFFFFFFFF
FC142
Y Y Y Y
42045
0x07FC
Relays
0xFFFFFFFF
FC198
Y Y Y Y
42047
0x07FE
Events
FC126
Y Y Y Y
42048
0x07FF
Targets
FC101
Y Y Y Y
FlexElement 6
42055
0x0806
Function
FC126
Y Y Y Y
42056
0x0807
Name
65535
F60_26
FlexEl 6
13
Y Y Y Y
42069
0x0814
Input 1 (+)
35903
FC273
Y Y Y Y
42070
0x0815
Input 2 (-)
35903
FC273
Y Y Y Y
42071
0x0816
FC378
Y Y Y Y
42072
0x0817
Operating Mode
FC379
Y Y Y Y
42073
0x0818
Operating Signal
Direction
FC275
Y Y Y Y
42074
0x0819
Pickup
-30000
30000
p.u.
F23
1000
Y Y Y Y
42075
0x081A
Hysteresis
500
42076
0x081B
42077
0x081C
40
65535
42078
0x081D
Pickup Delay
6000000
42080
0x081F
Dropout Delay
6000000
F1
30
Y Y Y Y
FC141
Y Y Y Y
F0
40
Y Y Y Y
F13
Y Y Y Y
F13
Y Y Y Y
42082
0x0821
Block
0xFFFFFFFF
FC142
Y Y Y Y
42084
0x0823
Relays
0xFFFFFFFF
FC198
Y Y Y Y
42086
0x0825
Events
FC126
Y Y Y Y
42087
0x0826
Targets
FC101
Y Y Y Y
FlexElement 7
42094
0x082D
Function
FC126
Y Y Y Y
42095
0x082E
Name
65535
F60_26
FlexEl 7
13
Y Y Y Y
42108
0x083B
Input 1 (+)
35903
FC273
Y Y Y Y
42109
0x083C
Input 2 (-)
35903
FC273
Y Y Y Y
42110
0x083D
FC378
Y Y Y Y
42111
0x083E
Operating Mode
FC379
Y Y Y Y
11-80
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
42112
0x083F
Operating Signal
Direction
FC275
Y Y Y Y
42113
0x0840
Pickup
-30000
30000
p.u.
F23
1000
Y Y Y Y
42114
0x0841
Hysteresis
500
F1
30
Y Y Y Y
42115
0x0842
FC141
Y Y Y Y
F0
40
Y Y Y Y
F13
Y Y Y Y
42116
0x0843
40
65535
42117
0x0844
Pickup Delay
6000000
s
s
42119
0x0846
Dropout Delay
6000000
F13
Y Y Y Y
42121
0x0848
Block
0xFFFFFFFF
FC142
Y Y Y Y
42123
0x084A
Relays
0xFFFFFFFF
FC198
Y Y Y Y
42125
0x084C
Events
FC126
Y Y Y Y
42126
0x084D
Targets
FC101
Y Y Y Y
FlexElement 8
42133
0x0854
Function
FC126
Y Y Y Y
42134
0x0855
Name
65535
F60_26
FlexEl 8
13
Y Y Y Y
42147
0x0862
Input 1 (+)
35903
FC273
Y Y Y Y
42148
0x0863
Input 2 (-)
35903
FC273
Y Y Y Y
42149
0x0864
FC378
Y Y Y Y
42150
0x0865
Operating Mode
FC379
Y Y Y Y
42151
0x0866
Operating Signal
Direction
FC275
Y Y Y Y
42152
0x0867
Pickup
-30000
30000
p.u.
F23
1000
Y Y Y Y
42153
0x0868
Hysteresis
500
F1
30
Y Y Y Y
42154
0x0869
FC141
Y Y Y Y
F0
40
Y Y Y Y
F13
Y Y Y Y
42155
0x086A
40
65535
42156
0x086B
Pickup Delay
6000000
s
s
42158
0x086D
Dropout Delay
6000000
F13
Y Y Y Y
42160
0x086F
Block
0xFFFFFFFF
FC142
Y Y Y Y
42162
0x0871
Relays
0xFFFFFFFF
FC198
Y Y Y Y
42164
0x0873
Events
FC126
Y Y Y Y
42165
0x0874
Targets
FC101
Y Y Y Y
0x09FF
FC123
Y Y Y Y
42561
0x0A00
FC123
Y Y Y Y
65535
F60_26
CI 1
13
Y Y Y Y
Contact Input 1
42580
0x0A13
Name
42593
0x0A20
Debounce Time
160
42594
0x0A21
Events
ms
F1
100
Y Y Y Y
FC126
Y Y Y Y
Y Y Y Y
Contact Input 2
42595
0x0A22
Name
65535
42608
0x0A2F
Debounce Time
160
F60_26
CI 2
13
F1
100
42609
0x0A30
Events
Y Y Y Y
FC126
Y Y Y Y
F60_26
CI 3
13
Y Y Y Y
F1
100
Y Y Y Y
ms
Contact Input 3
42610
0x0A31
Name
65535
42623
0x0A3E
Debounce Time
160
ms
11-81
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
42624
FC126
Y Y Y Y
0x0A3F
Events
Contact Input 4
42625
0x0A40
Name
65535
42638
160
42639
0x0A4E
Events
ms
F60_26
CI 4
13
Y Y Y Y
F1
100
Y Y Y Y
FC126
Y Y Y Y
Contact Input 5
42640
0x0A4F
Name
65535
42653
0x0A5C
Debounce Time
160
42654
0x0A5D Events
ms
F60_26
CI 5
13
Y Y Y Y
F1
100
Y Y Y Y
FC126
Y Y Y Y
Contact Input 6
42655
0x0A5E
Name
65535
42668
0x0A6B
Debounce Time
160
42669
0x0A6C
Events
ms
F60_26
CI 6
13
Y Y Y Y
F1
100
Y Y Y Y
FC126
Y Y Y Y
Contact Input 7
42670
0x0A6D Name
65535
42683
0x0A7A
Debounce Time
160
42684
0x0A7B
Events
ms
F60_26
CI 7
13
Y Y Y Y
F1
100
Y Y Y Y
FC126
Y Y Y Y
Contact Input 8
42685
0x0A7C
Name
65535
42698
0x0A89
Debounce Time
160
42699
0x0A8A
Events
ms
F60_26
CI 8
13
Y Y Y Y
F1
100
Y Y Y Y
FC126
Y Y Y Y
Contact Input 9
42700
0x0A8B
Name
65535
42713
0x0A98
Debounce Time
160
42714
0x0A99
Events
ms
F60_26
CI 9
13
Y Y Y Y
F1
100
Y Y Y Y
FC126
Y Y Y Y
Contact Input 10
42715
0x0A9A
Name
65535
42728
0x0AA7
Debounce Time
160
42729
0x0AA8
Events
ms
F60_26
CI 10
13
Y Y Y Y
F1
100
Y Y Y Y
FC126
Y Y Y Y
F60_26
CI 11
13
Y Y Y Y
F1
100
Y Y Y Y
FC126
Y Y Y Y
Contact Input 11
42730
0x0AA9
Name
65535
42743
0x0AB6
Debounce Time
160
42744
0x0AB7
Events
ms
Contact Input 12
42745
0x0AB8
Name
65535
42758
0x0AC5
Debounce Time
160
42759
0x0AC6
Events
ms
F60_26
CI 12
13
Y Y Y Y
F1
100
Y Y Y Y
FC126
Y Y Y Y
Contact Input 13
42760
0x0AC7
Name
65535
42773
160
42774
0x0AD5 Events
ms
F60_26
CI 13
13
Y Y Y Y
F1
100
Y Y Y Y
FC126
Y Y Y Y
Contact Input 14
42775
0x0AD6 Name
65535
42788
0x0AE3
Debounce Time
160
42789
0x0AE4
Events
11-82
ms
F60_26
CI 14
13
Y Y Y Y
F1
100
Y Y Y Y
FC126
Y Y Y Y
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
Contact Input 15
42790
0x0AE5
Name
65535
42803
0x0AF2
Debounce Time
160
F60_26
CI 15
13
Y Y Y Y
F1
100
Y Y Y Y
42804
0x0AF3
Events
FC126
Y Y Y Y
65535
F60_26
CI 16
13
Y Y Y Y
ms
Contact Input 16
42805
0x0AF4
Name
42818
0x0B01
Debounce Time
160
42819
0x0B02
Events
ms
F1
100
Y Y Y Y
FC126
Y Y Y Y
F60_26
CI 17
13
Y Y Y Y
F1
100
Y Y Y Y
Contact Input 17
42820
0x0B03
Name
65535
42833
0x0B10
Debounce Time
160
42834
0x0B11
Events
FC126
Y Y Y Y
65535
F60_26
CI 18
13
Y Y Y Y
ms
Contact Input 18
42835
0x0B12
Name
42848
0x0B1F
Debounce Time
160
42849
0x0B20
Events
ms
F1
100
Y Y Y Y
FC126
Y Y Y Y
F60_26
CI 19
13
Y Y Y Y
F1
100
Y Y Y Y
Contact Input 19
42850
0x0B21
Name
65535
42863
0x0B2E
Debounce Time
160
42864
0x0B2F
Events
FC126
Y Y Y Y
Name
65535
F60_26
CI 20
13
Y Y Y Y
ms
Contact Input 20
42865
0x0B30
42878
160
42879
0x0B3E
Events
ms
F1
100
Y Y Y Y
FC126
Y Y Y Y
F60_26
CI 21
13
Y Y Y Y
F1
100
Y Y Y Y
Contact Input 21
42880
0x0B3F
Name
65535
42893
0x0B4C
Debounce Time
160
42894
0x0B4D Events
FC126
Y Y Y Y
65535
F60_26
CI 22
13
Y Y Y Y
ms
Contact Input 22
42895
0x0B4E
Name
42908
0x0B5B
Debounce Time
160
42909
0x0B5C
Events
42910
0x0B5D Name
65535
42923
0x0B6A
Debounce Time
160
42924
0x0B6B
Events
65535
ms
F1
100
Y Y Y Y
FC126
Y Y Y Y
F60_26
CI 23
13
Y Y Y Y
F1
100
Y Y Y Y
FC126
Y Y Y Y
F60_26
CI 24
13
Y Y Y Y
Contact Input 23
ms
Contact Input 24
42925
0x0B6C
Name
42938
0x0B79
Debounce Time
160
42939
0x0B7A
Events
ms
F1
100
Y Y Y Y
FC126
Y Y Y Y
F60_26
CI 25
13
Y Y Y Y
F1
100
Y Y Y Y
FC126
Y Y Y Y
Contact Input 25
42940
0x0B7B
Name
65535
42953
0x0B88
Debounce Time
160
42954
0x0B89
Events
ms
Contact Input 26
11-83
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
42955
0x0B8A
Name
65535
F60_26
CI 26
13
Y Y Y Y
42968
0x0B97
Debounce Time
160
F1
100
Y Y Y Y
42969
0x0B98
Events
FC126
Y Y Y Y
ms
Contact Input 27
42970
0x0B99
Name
65535
42983
0x0BA6
Debounce Time
160
F60_26
CI 27
13
Y Y Y Y
F1
100
Y Y Y Y
42984
0x0BA7
Events
FC126
Y Y Y Y
F60_26
CI 28
13
Y Y Y Y
F1
100
Y Y Y Y
FC126
Y Y Y Y
ms
Contact Input 28
42985
0x0BA8
Name
65535
42998
0x0BB5
Debounce Time
160
42999
0x0BB6
Events
ms
Contact Input 29
43000
0x0BB7
Name
65535
43013
0x0BC4
Debounce Time
160
F60_26
CI 29
13
Y Y Y Y
F1
100
Y Y Y Y
43014
0x0BC5
Events
FC126
Y Y Y Y
Name
65535
F60_26
CI 30
13
Y Y Y Y
ms
Contact Input 30
43015
0x0BC6
43028
160
43029
0x0BD4 Events
ms
F1
100
Y Y Y Y
FC126
Y Y Y Y
Contact Input 31
43030
0x0BD5 Name
65535
43043
0x0BE2
Debounce Time
160
F60_26
CI 31
13
Y Y Y Y
F1
100
Y Y Y Y
43044
0x0BE3
Events
FC126
Y Y Y Y
F60_26
CI 32
13
Y Y Y Y
ms
Contact Input 32
43045
0x0BE4
Name
65535
43058
0x0BF1
Debounce Time
160
F1
100
Y Y Y Y
43059
0x0BF2
Events
FC126
Y Y Y Y
ms
Virtual Input 1
43130
0x0C39
Function
FC126
Y Y Y Y
43131
0x0C3A
Name
65535
F60_26
VI 1
13
Y Y Y Y
43144
0x0C47
Type
FC199
Y Y Y Y
43145
0x0C48
Events
FC126
Y Y Y Y
Y Y Y Y
Virtual Input 2
43146
0x0C49
Function
FC126
43147
0x0C4A
Name
65535
F60_26
VI 2
13
Y Y Y Y
43160
0x0C57
Type
FC199
Y Y Y Y
43161
0x0C58
Events
FC126
Y Y Y Y
Y Y Y Y
Virtual Input 3
43162
0x0C59
Function
FC126
43163
0x0C5A
Name
65535
F60_26
VI 3
13
Y Y Y Y
43176
0x0C67
Type
FC199
Y Y Y Y
43177
0x0C68
Events
FC126
Y Y Y Y
Virtual Input 4
43178
0x0C69
Function
FC126
Y Y Y Y
43179
0x0C6A
Name
65535
F60_26
VI 4
13
Y Y Y Y
11-84
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
43192
0x0C77
Type
FC199
Y Y Y Y
43193
0x0C78
Events
FC126
Y Y Y Y
Function
FC126
Y Y Y Y
Virtual Input 5
43194
0x0C79
43195
0x0C7A
Name
65535
F60_26
VI 5
13
Y Y Y Y
43208
0x0C87
Type
FC199
Y Y Y Y
43209
0x0C88
Events
FC126
Y Y Y Y
Function
FC126
Y Y Y Y
Virtual Input 6
43210
0x0C89
43211
0x0C8A
Name
65535
F60_26
VI 6
13
Y Y Y Y
43224
0x0C97
Type
FC199
Y Y Y Y
43225
0x0C98
Events
FC126
Y Y Y Y
Function
FC126
Y Y Y Y
Virtual Input 7
43226
0x0C99
43227
0x0C9A
Name
65535
F60_26
VI 7
13
Y Y Y Y
43240
0x0CA7
Type
FC199
Y Y Y Y
43241
0x0CA8
Events
FC126
Y Y Y Y
FC126
Y Y Y Y
65535
F60_26
VI 8
13
Y Y Y Y
Virtual Input 8
43242
0x0CA9
43243
0x0CAA Name
Function
43256
0x0CB7
Type
FC199
Y Y Y Y
43257
0x0CB8
Events
FC126
Y Y Y Y
Function
FC126
Y Y Y Y
65535
F60_26
VI 9
13
Y Y Y Y
Virtual Input 9
43258
0x0CB9
43259
0x0CBA Name
43272
0x0CC7
Type
FC199
Y Y Y Y
43273
0x0CC8
Events
FC126
Y Y Y Y
Function
FC126
Y Y Y Y
65535
F60_26
VI 10
13
Y Y Y Y
Virtual Input 10
43274
0x0CC9
43275
0x0CCA Name
43288
0x0CD7 Type
FC199
Y Y Y Y
43289
0x0CD8 Events
FC126
Y Y Y Y
Y Y Y Y
Virtual Input 11
43290
0x0CD9 Function
FC126
43291
0x0CDA Name
65535
F60_26
VI 11
13
Y Y Y Y
43304
0x0CE7
Type
FC199
Y Y Y Y
43305
0x0CE8
Events
FC126
Y Y Y Y
Virtual Input 12
43306
0x0CE9
Function
FC126
Y Y Y Y
43307
0x0CEA
Name
65535
F60_26
VI 12
13
Y Y Y Y
43320
0x0CF7
Type
FC199
Y Y Y Y
43321
0x0CF8
Events
FC126
Y Y Y Y
Virtual Input 13
43322
0x0CF9
Function
FC126
Y Y Y Y
43323
0x0CFA
Name
65535
F60_26
VI 13
13
Y Y Y Y
11-85
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
43336
0x0D07
Type
FC199
Y Y Y Y
43337
0x0D08
Events
FC126
Y Y Y Y
Function
FC126
Y Y Y Y
Virtual Input 14
43338
0x0D09
43339
0x0D0A Name
65535
F60_26
VI 14
13
Y Y Y Y
43352
0x0D17
Type
FC199
Y Y Y Y
43353
0x0D18
Events
FC126
Y Y Y Y
Function
FC126
Y Y Y Y
Virtual Input 15
43354
0x0D19
43355
0x0D1A Name
65535
F60_26
VI 15
13
Y Y Y Y
43368
0x0D27
Type
FC199
Y Y Y Y
43369
0x0D28
Events
FC126
Y Y Y Y
Function
FC126
Y Y Y Y
Virtual Input 16
43370
0x0D29
43371
0x0D2A Name
65535
F60_26
VI 16
13
Y Y Y Y
43384
0x0D37
Type
FC199
Y Y Y Y
43385
0x0D38
Events
FC126
Y Y Y Y
Function
Virtual Input 17
43386
0x0D39
FC126
Y Y Y Y
43387
0x0D3A Name
65535
F60_26
VI 17
13
Y Y Y Y
43400
0x0D47
Type
FC199
Y Y Y Y
43401
0x0D48
Events
FC126
Y Y Y Y
Function
Virtual Input 18
43402
0x0D49
FC126
Y Y Y Y
43403
0x0D4A Name
65535
F60_26
VI 18
13
Y Y Y Y
43416
0x0D57
Type
FC199
Y Y Y Y
43417
0x0D58
Events
FC126
Y Y Y Y
Function
Virtual Input 19
43418
0x0D59
FC126
Y Y Y Y
43419
0x0D5A Name
65535
F60_26
VI 19
13
Y Y Y Y
43432
0x0D67
Type
FC199
Y Y Y Y
43433
0x0D68
Events
FC126
Y Y Y Y
Function
Y Y Y Y
Virtual Input 20
43434
0x0D69
FC126
43435
0x0D6A Name
65535
F60_26
VI 20
13
Y Y Y Y
43448
0x0D77
Type
FC199
Y Y Y Y
43449
0x0D78
Events
FC126
Y Y Y Y
Function
Y Y Y Y
Virtual Input 21
43450
0x0D79
FC126
43451
0x0D7A Name
65535
F60_26
VI 21
13
Y Y Y Y
43464
0x0D87
Type
FC199
Y Y Y Y
43465
0x0D88
Events
FC126
Y Y Y Y
Function
FC126
Y Y Y Y
65535
F60_26
VI 22
13
Y Y Y Y
Virtual Input 22
43466
0x0D89
43467
0x0D8A Name
11-86
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
43480
0x0D97
Type
FC199
Y Y Y Y
43481
0x0D98
Events
FC126
Y Y Y Y
Function
FC126
Y Y Y Y
Virtual Input 23
43482
0x0D99
43483
0x0D9A Name
65535
F60_26
VI 23
13
Y Y Y Y
43496
0x0DA7 Type
FC199
Y Y Y Y
43497
0x0DA8 Events
FC126
Y Y Y Y
FC126
Y Y Y Y
Virtual Input 24
43498
0x0DA9 Function
43499
0x0DAA Name
65535
F60_26
VI 24
13
Y Y Y Y
43512
0x0DB7 Type
FC199
Y Y Y Y
43513
0x0DB8 Events
FC126
Y Y Y Y
0x0DB9 Function
FC126
Y Y Y Y
43515
0x0DBA Name
65535
F60_26
VI 25
13
Y Y Y Y
43528
0x0DC7 Type
FC199
Y Y Y Y
43529
0x0DC8 Events
FC126
Y Y Y Y
Virtual Input 25
43514
Virtual Input 26
43530
0x0DC9 Function
FC126
Y Y Y Y
43531
0x0DCA Name
65535
F60_26
VI 26
13
Y Y Y Y
43544
0x0DD7 Type
FC199
Y Y Y Y
43545
0x0DD8 Events
FC126
Y Y Y Y
Virtual Input 27
43546
0x0DD9 Function
FC126
Y Y Y Y
43547
0x0DDA Name
65535
F60_26
VI 27
13
Y Y Y Y
43560
0x0DE7
Type
FC199
Y Y Y Y
43561
0x0DE8
Events
FC126
Y Y Y Y
Function
Virtual Input 28
43562
0x0DE9
FC126
Y Y Y Y
43563
0x0DEA Name
65535
F60_26
VI 28
13
Y Y Y Y
43576
0x0DF7
Type
FC199
Y Y Y Y
43577
0x0DF8
Events
FC126
Y Y Y Y
Virtual Input 29
43578
0x0DF9
Function
FC126
Y Y Y Y
43579
0x0DFA
Name
65535
F60_26
VI 29
13
Y Y Y Y
43592
0x0E07
Type
FC199
Y Y Y Y
43593
0x0E08
Events
FC126
Y Y Y Y
Y Y Y Y
Virtual Input 30
43594
0x0E09
Function
FC126
43595
0x0E0A
Name
65535
F60_26
VI 30
13
Y Y Y Y
43608
0x0E17
Type
FC199
Y Y Y Y
43609
0x0E18
Events
FC126
Y Y Y Y
Virtual Input 31
43610
0x0E19
Function
FC126
Y Y Y Y
43611
0x0E1A
Name
65535
F60_26
VI 31
13
Y Y Y Y
11-87
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
43624
0x0E27
Type
FC199
Y Y Y Y
43625
0x0E28
Events
FC126
Y Y Y Y
Function
FC126
Y Y Y Y
Virtual Input 32
43626
0x0E29
43627
0x0E2A
Name
65535
F60_26
VI 32
13
Y Y Y Y
43640
0x0E37
Type
FC199
Y Y Y Y
43641
0x0E38
Events
FC126
Y Y Y Y
Remote Input 1
45190
0x1445
Events
FC126
Y Y Y Y
45191
0x1446
Name
65535
F60_26
RI 1
13
Y Y Y Y
Remote Input 2
45204
0x1453
Events
FC126
Y Y Y Y
45205
0x1454
Name
65535
F60_26
RI 2
13
Y Y Y Y
Remote Input 3
45218
0x1461
Events
FC126
Y Y Y Y
45219
0x1462
Name
65535
F60_26
RI 3
13
Y Y Y Y
Remote Input 4
45232
0x146F
Events
FC126
Y Y Y Y
45233
0x1470
Name
65535
F60_26
RI 4
13
Y Y Y Y
Remote Input 5
45246
0x147D
Events
FC126
Y Y Y Y
45247
0x147E
Name
65535
F60_26
RI 5
13
Y Y Y Y
Remote Input 6
45260
0x148B
Events
FC126
Y Y Y Y
45261
0x148C
Name
65535
F60_26
RI 6
13
Y Y Y Y
Remote Input 7
45274
0x1499
Events
FC126
Y Y Y Y
45275
0x149A
Name
65535
F60_26
RI 7
13
Y Y Y Y
Remote Input 8
45288
0x14A7
Events
FC126
Y Y Y Y
45289
0x14A8
Name
65535
F60_26
RI 8
13
Y Y Y Y
Remote Input 9
45302
0x14B5
Events
FC126
Y Y Y Y
45303
0x14B6
Name
65535
F60_26
RI 9
13
Y Y Y Y
Remote Input 10
45316
0x14C3
Events
FC126
Y Y Y Y
45317
0x14C4
Name
65535
F60_26
RI 10
13
Y Y Y Y
Remote Input 11
45330
0x14D1
Events
FC126
Y Y Y Y
45331
0x14D2
Name
65535
F60_26
RI 11
13
Y Y Y Y
Remote Input 12
45344
0x14DF
Events
FC126
Y Y Y Y
45345
0x14E0
Name
65535
F60_26
RI 12
13
Y Y Y Y
Events
FC126
Y Y Y Y
Remote Input 13
45358
11-88
0x14ED
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
45359
65535
F60_26
RI 13
13
Y Y Y Y
0x14EE
Name
Remote Input 14
45372
0x14FB
Events
FC126
Y Y Y Y
45373
0x14FC
Name
65535
F60_26
RI 14
13
Y Y Y Y
Remote Input 15
45386
0x1509
Events
FC126
Y Y Y Y
45387
0x150A
Name
65535
F60_26
RI 15
13
Y Y Y Y
Remote Input 16
45400
0x1517
Events
FC126
Y Y Y Y
45401
0x1518
Name
65535
F60_26
RI 16
13
Y Y Y Y
Remote Input 17
45414
0x1525
Events
FC126
Y Y Y Y
45415
0x1526
Name
65535
F60_26
RI 17
13
Y Y Y Y
Remote Input 18
45428
0x1533
Events
FC126
Y Y Y Y
45429
0x1534
Name
65535
F60_26
RI 18
13
Y Y Y Y
Remote Input 19
45442
0x1541
Events
FC126
Y Y Y Y
45443
0x1542
Name
65535
F60_26
RI 19
13
Y Y Y Y
Remote Input 20
45456
0x154F
Events
FC126
Y Y Y Y
45457
0x1550
Name
65535
F60_26
RI 20
13
Y Y Y Y
Remote Input 21
45470
0x155D
Events
FC126
Y Y Y Y
45471
0x155E
Name
65535
F60_26
RI 21
13
Y Y Y Y
Remote Input 22
45484
0x156B
Events
FC126
Y Y Y Y
45485
0x156C
Name
65535
F60_26
RI 22
13
Y Y Y Y
Remote Input 23
45498
0x1579
Events
FC126
Y Y Y Y
45499
0x157A
Name
65535
F60_26
RI 23
13
Y Y Y Y
Remote Input 24
45512
0x1587
Events
FC126
Y Y Y Y
45513
0x1588
Name
65535
F60_26
RI 24
13
Y Y Y Y
Remote Input 25
45526
0x1595
Events
FC126
Y Y Y Y
45527
0x1596
Name
65535
F60_26
RI 25
13
Y Y Y Y
Remote Input 26
45540
0x15A3
Events
FC126
Y Y Y Y
45541
0x15A4
Name
65535
F60_26
RI 26
13
Y Y Y Y
Remote Input 27
45554
0x15B1
Events
FC126
Y Y Y Y
45555
0x15B2
Name
65535
F60_26
RI 27
13
Y Y Y Y
Events
FC126
Y Y Y Y
Remote Input 28
45568
0x15BF
11-89
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
45569
65535
F60_26
RI 28
13
Y Y Y Y
0x15C0
Name
Remote Input 29
45582
0x15CD Events
FC126
Y Y Y Y
45583
0x15CE
Name
65535
F60_26
RI 29
13
Y Y Y Y
45596
0x15DB Events
FC126
Y Y Y Y
45597
0x15DC Name
65535
F60_26
RI 30
13
Y Y Y Y
Remote Input 30
Remote Input 31
45610
0x15E9
Events
FC126
Y Y Y Y
45611
0x15EA
Name
65535
F60_26
RI 31
13
Y Y Y Y
Remote Input 32
45624
0x15F7
Events
FC126
Y Y Y Y
45625
0x15F8
Name
65535
F60_26
RI 32
13
Y Y Y Y
Output Relay 1
47000
0x1B57
Name
65535
F60_26
Trip
13
Y Y Y Y
47013
0x1B64
Operate
0xFFFFFFFF
FC142
Y Y Y Y
47016
0x1B67
Seal-In Time
999
F2
10
Y Y Y Y
47017
0x1B68
Type
FC278
Y Y Y Y
47018
0x1B69
Operation
FC208
Y Y Y Y
47019
0x1B6A
Events
FC126
Y Y Y Y
47020
0x1B6B
Block
0xFFFFFFFF
FC142
Y Y Y Y
Output Relay 2
47022
0x1B6D Name
65535
F60_26
Close
13
Y Y Y Y
47035
0x1B7A
0xFFFFFFFF
FC142
Y Y Y Y
47038
999
F2
10
Y Y Y Y
47039
0x1B7E
Type
FC278
Y Y Y Y
47040
0x1B7F
Operation
FC208
Y Y Y Y
47041
0x1B80
Events
FC126
Y Y Y Y
47042
0x1B81
Block
0xFFFFFFFF
FC142
Y Y Y Y
F60_26
Aux Relay 13
3
Y Y Y Y
FC142
Y Y Y Y
F2
10
Y Y Y Y
Operate
Output Relay 3
47044
0x1B83
65535
47057
0x1B90
Operate
0xFFFFFFFF
47060
0x1B93
Seal-In Time
999
47061
0x1B94
Type
FC278
Y Y Y Y
47062
0x1B95
Operation
FC208
Y Y Y Y
47063
0x1B96
Events
FC126
Y Y Y Y
47064
0x1B97
Block
0xFFFFFFFF
FC142
Y Y Y Y
Output Relay 4
47066
0x1B99
65535
F60_26
Aux Relay 13
4
Y Y Y Y
47079
0x1BA6
Operate
0xFFFFFFFF
FC142
Y Y Y Y
47082
0x1BA9
Seal-In Time
999
F2
10
Y Y Y Y
47083
0x1BAA Type
FC278
Y Y Y Y
47084
0x1BAB Operation
FC208
Y Y Y Y
47085
0x1BAC Events
FC126
Y Y Y Y
11-90
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
47086
0xFFFFFFFF
FC142
65535
F60_26
Aux Relay 13
5
Y Y Y Y
FC142
Y Y Y Y
F2
10
Y Y Y Y
FC278
Y Y Y Y
0x1BAD Block
Y Y Y Y
Output Relay 5
47088
0x1BAF
47101
0x1BBC Operate
0xFFFFFFFF
47104
0x1BBF
Seal-In Time
999
47105
0x1BC0
Type
47106
0x1BC1
Operation
FC208
Y Y Y Y
47107
0x1BC2
Events
FC126
Y Y Y Y
47108
0x1BC3
Block
0xFFFFFFFF
FC142
Y Y Y Y
65535
F60_26
Aux Relay 13
6
Y Y Y Y
FC142
Y Y Y Y
F2
10
Y Y Y Y
FC278
Y Y Y Y
Output Relay 6
47110
0x1BC5
47123
0x1BD2 Operate
0xFFFFFFFF
47126
999
47127
0x1BD6 Type
47128
0x1BD7 Operation
FC208
Y Y Y Y
47129
0x1BD8 Events
FC126
Y Y Y Y
47130
0x1BD9 Block
0xFFFFFFFF
FC142
Y Y Y Y
F60_26
Aux Relay 13
7
Y Y Y Y
FC142
Y Y Y Y
F2
10
Y Y Y Y
Output Relay 7
47132
65535
47145
0x1BE8
Operate
0xFFFFFFFF
47148
0x1BEB
Seal-In Time
999
47149
0x1BEC
Type
FC278
Y Y Y Y
47150
0x1BED Operation
FC208
Y Y Y Y
47151
0x1BEE
Events
FC126
Y Y Y Y
47152
0x1BEF
Block
0xFFFFFFFF
FC142
Y Y Y Y
F60_26
Critical Fail 13
Y Y Y Y
FC142
0x803202 2
Y Y Y Y
F2
10
Y Y Y Y
Y Y Y Y
0x1BF1
CF Relay Name
65535
47167
0x1BFE
Operate
0xFFFFFFFF
47170
0x1C01
Seal-In Time
999
47171
0x1C02
Type
FC278
47172
0x1C03
Operation
FC208
Y Y Y Y
47173
0x1C04
Events
FC126
Y Y Y Y
47174
0x1C05
Block
0xFFFFFFFF
FC142
Y Y Y Y
F60_26
Aux Relay 13
9
Y Y Y Y
FC142
Y Y Y Y
F2
10
Y Y Y Y
Y Y Y Y
Output Relay 9
47176
0x1C07
65535
47189
0x1C14
Operate
0xFFFFFFFF
47192
0x1C17
Seal-In Time
999
47193
0x1C18
Type
FC278
47194
0x1C19
Operation
FC208
Y Y Y Y
47195
0x1C1A
Events
FC126
Y Y Y Y
47196
0x1C1B
Block
0xFFFFFFFF
FC142
Y Y Y Y
Output Relay 10
11-91
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
47198
65535
F60_26
Aux Relay 13
10
Y Y Y Y
47211
0x1C2A
0xFFFFFFFF
FC142
Y Y Y Y
47214
999
F2
10
Y Y Y Y
47215
0x1C2E
Type
FC278
Y Y Y Y
47216
0x1C2F
Operation
FC208
Y Y Y Y
47217
0x1C30
Events
FC126
Y Y Y Y
47218
0x1C31
Block
0xFFFFFFFF
FC142
Y Y Y Y
F60_26
Aux Relay 13
11
Y Y Y Y
FC142
Y Y Y Y
F2
10
Y Y Y Y
Operate
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
Output Relay 11
47220
0x1C33
65535
47233
0x1C40
Operate
0xFFFFFFFF
47236
0x1C43
Seal-In Time
999
47237
0x1C44
Type
FC278
Y Y Y Y
47238
0x1C45
Operation
FC208
Y Y Y Y
47239
0x1C46
Events
FC126
Y Y Y Y
47240
0x1C47
Block
0xFFFFFFFF
FC142
Y Y Y Y
F60_26
Aux Relay 13
12
Y Y Y Y
FC142
Y Y Y Y
F2
10
Y Y Y Y
Output Relay 12
47242
0x1C49
65535
47255
0x1C56
Operate
0xFFFFFFFF
47258
0x1C59
Seal-In Time
999
47259
0x1C5A
Type
FC278
Y Y Y Y
47260
0x1C5B
Operation
FC208
Y Y Y Y
47261
0x1C5C
Events
47262
0x1C5D Block
FC126
Y Y Y Y
0xFFFFFFFF
FC142
Y Y Y Y
Output Relay 13
47264
0x1C5F
65535
F60_26
Aux Relay 13
13
Y Y Y Y
47277
0x1C6C
Operate
0xFFFFFFFF
FC142
Y Y Y Y
47280
0x1C6F
Seal-In Time
999
F2
10
Y Y Y Y
47281
0x1C70
Type
FC278
Y Y Y Y
47282
0x1C71
Operation
FC208
Y Y Y Y
47283
0x1C72
Events
FC126
Y Y Y Y
47284
0x1C73
Block
0xFFFFFFFF
FC142
Y Y Y Y
Output Relay 14
47286
0x1C75
65535
F60_26
Aux Relay 13
14
Y Y Y Y
47299
0x1C82
Operate
0xFFFFFFFF
FC142
Y Y Y Y
47302
0x1C85
Seal-In Time
999
F2
10
Y Y Y Y
47303
0x1C86
Type
FC278
Y Y Y Y
47304
0x1C87
Operation
FC208
Y Y Y Y
47305
0x1C88
Events
FC126
Y Y Y Y
47306
0x1C89
Block
0xFFFFFFFF
FC142
Y Y Y Y
65535
F60_26
Aux Relay 13
15
Output Relay 15
47308
11-92
0x1C8B
Y Y Y Y
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
47321
0xFFFFFFFF
FC142
0x1C98
Operate
Y Y Y Y
47324
0x1C9B
Seal-In Time
999
F2
10
Y Y Y Y
47325
0x1C9C
Type
FC278
Y Y Y Y
47326
0x1C9D Operation
FC208
Y Y Y Y
47327
0x1C9E
Events
FC126
Y Y Y Y
47328
0x1C9F
Block
0xFFFFFFFF
FC142
Y Y Y Y
Output Relay 16
47330
0x1CA1
65535
F60_26
Aux Relay 13
16
Y Y Y Y
47343
0x1CAE
Operate
0xFFFFFFFF
FC142
Y Y Y Y
47346
0x1CB1
Seal-In Time
999
47347
0x1CB2
Type
F2
10
Y Y Y Y
FC278
Y Y Y Y
47348
0x1CB3
Operation
FC208
Y Y Y Y
47349
0x1CB4
Events
FC126
Y Y Y Y
47350
0x1CB5
Block
0xFFFFFFFF
FC142
Y Y Y Y
Virtual Output 1
47720
0x1E27
Name
65535
F60_26
VO 1
13
Y Y Y Y
47733
0x1E34
Events
FC126
Y Y Y Y
Virtual Output 2
47734
0x1E35
Name
65535
F60_26
VO 2
13
Y Y Y Y
47747
0x1E42
Events
FC126
Y Y Y Y
Virtual Output 3
47748
0x1E43
Name
65535
F60_26
VO 3
13
Y Y Y Y
47761
0x1E50
Events
FC126
Y Y Y Y
Virtual Output 4
47762
0x1E51
Name
65535
F60_26
VO 4
13
Y Y Y Y
47775
0x1E5E
Events
FC126
Y Y Y Y
Virtual Output 5
47776
0x1E5F
Name
65535
F60_26
VO 5
13
Y Y Y Y
47789
0x1E6C
Events
FC126
Y Y Y Y
Virtual Output 6
47790
0x1E6D
Name
65535
F60_26
VO 6
13
Y Y Y Y
47803
0x1E7A
Events
FC126
Y Y Y Y
Virtual Output 7
47804
0x1E7B
Name
65535
F60_26
VO 7
13
Y Y Y Y
47817
0x1E88
Events
FC126
Y Y Y Y
Virtual Output 8
47818
0x1E89
Name
65535
F60_26
VO 8
13
Y Y Y Y
47831
0x1E96
Events
FC126
Y Y Y Y
Virtual Output 9
47832
0x1E97
Name
65535
F60_26
VO 9
13
Y Y Y Y
47845
0x1EA4
Events
FC126
Y Y Y Y
Virtual Output 10
47846
0x1EA5
Name
65535
F60_26
VO 10
13
Y Y Y Y
47859
0x1EB2
Events
FC126
Y Y Y Y
Virtual Output 11
11-93
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
47860
0x1EB3
Name
65535
F60_26
VO 11
13
Y Y Y Y
47873
0x1EC0
Events
FC126
Y Y Y Y
Virtual Output 12
47874
0x1EC1
Name
65535
F60_26
VO 12
13
Y Y Y Y
47887
0x1ECE
Events
FC126
Y Y Y Y
Virtual Output 13
47888
0x1ECF
Name
65535
F60_26
VO 13
13
Y Y Y Y
47901
0x1EDC Events
FC126
Y Y Y Y
Virtual Output 14
47902
0x1EDD Name
65535
F60_26
VO 14
13
Y Y Y Y
47915
0x1EEA
Events
FC126
Y Y Y Y
Virtual Output 15
47916
0x1EEB
Name
65535
F60_26
VO 15
13
Y Y Y Y
47929
0x1EF8
Events
FC126
Y Y Y Y
Virtual Output 16
47930
0x1EF9
Name
65535
F60_26
VO 16
13
Y Y Y Y
47943
0x1F06
Events
FC126
Y Y Y Y
Virtual Output 17
47944
0x1F07
Name
65535
F60_26
VO 17
13
Y Y Y Y
47957
0x1F14
Events
FC126
Y Y Y Y
Virtual Output 18
47958
0x1F15
Name
65535
F60_26
VO 18
13
Y Y Y Y
47971
0x1F22
Events
FC126
Y Y Y Y
Virtual Output 19
47972
0x1F23
Name
65535
F60_26
VO 19
13
Y Y Y Y
47985
0x1F30
Events
FC126
Y Y Y Y
Virtual Output 20
47986
0x1F31
Name
65535
F60_26
VO 20
13
Y Y Y Y
47999
0x1F3E
Events
FC126
Y Y Y Y
Virtual Output 21
48000
0x1F3F
Name
65535
F60_26
VO 21
13
Y Y Y Y
48013
0x1F4C
Events
FC126
Y Y Y Y
Virtual Output 22
48014
0x1F4D
Name
65535
F60_26
VO 22
13
Y Y Y Y
48027
0x1F5A
Events
FC126
Y Y Y Y
Virtual Output 23
48028
0x1F5B
Name
65535
F60_26
VO 23
13
Y Y Y Y
48041
0x1F68
Events
FC126
Y Y Y Y
Virtual Output 24
48042
0x1F69
Name
65535
F60_26
VO 24
13
Y Y Y Y
48055
0x1F76
Events
FC126
Y Y Y Y
Virtual Output 25
48056
0x1F77
Name
65535
F60_26
VO 25
13
Y Y Y Y
48069
0x1F84
Events
FC126
Y Y Y Y
Virtual Output 26
11-94
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
48070
0x1F85
Name
65535
F60_26
VO 26
13
Y Y Y Y
48083
0x1F92
Events
FC126
Y Y Y Y
Virtual Output 27
48084
0x1F93
Name
65535
F60_26
VO 27
13
Y Y Y Y
48097
0x1FA0
Events
FC126
Y Y Y Y
Virtual Output 28
48098
0x1FA1
Name
65535
F60_26
VO 28
13
Y Y Y Y
48111
0x1FAE
Events
FC126
Y Y Y Y
Virtual Output 29
48112
0x1FAF
Name
65535
F60_26
VO 29
13
Y Y Y Y
48125
0x1FBC
Events
FC126
Y Y Y Y
Virtual Output 30
48126
0x1FBD
Name
65535
F60_26
VO 30
13
Y Y Y Y
48139
0x1FCA
Events
FC126
Y Y Y Y
Virtual Output 31
48140
0x1FCB
Name
65535
F60_26
VO 31
13
Y Y Y Y
48153
0x1FD8
Events
FC126
Y Y Y Y
Virtual Output 32
48154
0x1FD9
Name
65535
F60_26
VO 32
13
Y Y Y Y
48167
0x1FE6
Events
FC126
Y Y Y Y
Analog Input 1
49520
0x252F
Function
FC386
Y Y Y Y
49521
0x2530
Name
65535
F60_26
AnIp 1
13
Y Y Y Y
49534
0x253D
Unit
65535
F60_6
units
Y Y Y Y
49537
0x2540
Range
FC274
Y Y Y Y
49538
0x2541
Min Value
-500000
500000
UserF30
Defined
@
Modbus
49534
Y Y Y Y
49540
0x2543
Max Value
-500000
500000
UserF30
Defined
@
Modbus
49534
Y Y Y Y
49542
0x2545
Trip Function
FC100D 0
Y Y Y Y
49543
0x2546
Trip Type
Y Y Y Y
49544
0x2547
Trip Pickup
-500000
500000
UserF30
Defined
@
Modbus
49534
20
Y Y Y Y
FC275
49546
0x2549
20
F0
Y Y Y Y
49547
0x254A
600
F0
Y Y Y Y
F0
49548
0x254B
600
Y Y Y Y
49549
0x254C
0xFFFFFFFF
FC198D 0
Y Y Y Y
49551
0x254E
Alarm Function
FC100E
Y Y Y Y
49552
0x254F
Alarm Type
FC275
Y Y Y Y
11-95
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
49553
0x2550
Alarm Pickup
-500000
500000
UserF30
Defined
@
Modbus
49534
10
Y Y Y Y
49555
0x2552
20
Y Y Y Y
49556
0x2553
600
F0
Y Y Y Y
49557
0x2554
600
F0
Y Y Y Y
49558
0x2555
0xFFFFFFFF
FC198C
Y Y Y Y
49560
0x2557
Block
0xFFFFFFFF
FC142
Y Y Y Y
49562
0x2559
Events
FC126
Y Y Y Y
49563
0x255A
Targets
FC101
Y Y Y Y
F0
Analog Input 2
49568
0x255F
Function
FC386
Y Y Y Y
49569
0x2560
Name
65535
F60_26
AnIp 2
13
Y Y Y Y
49582
0x256D
Unit
65535
F60_6
units
Y Y Y Y
49585
0x2570
Range
FC274
Y Y Y Y
49586
0x2571
Min Value
-500000
500000
UserF30
Defined
@
Modbus
49582
Y Y Y Y
49588
0x2573
Max Value
-500000
500000
UserF30
Defined
@
Modbus
49582
Y Y Y Y
49590
0x2575
Trip Function
FC100D 0
Y Y Y Y
49591
0x2576
Trip Type
49592
0x2577
Trip Pickup
-500000
500000
FC275
UserF30
Defined
@
Modbus
49582
Y Y Y Y
20
Y Y Y Y
49594
0x2579
20
F0
Y Y Y Y
49595
0x257A
600
F0
Y Y Y Y
F0
49596
0x257B
600
Y Y Y Y
49597
0x257C
0xFFFFFFFF
FC198D 0
Y Y Y Y
49599
0x257E
Alarm Function
FC100E
Y Y Y Y
49600
0x257F
Alarm Type
FC275
Y Y Y Y
49601
0x2580
Alarm Pickup
-500000
500000
UserF30
Defined
@
Modbus
49582
10
Y Y Y Y
49603
0x2582
20
Y Y Y Y
49604
0x2583
600
F0
Y Y Y Y
49605
0x2584
600
F0
Y Y Y Y
49606
0x2585
0xFFFFFFFF
FC198C
Y Y Y Y
49608
0x2587
Block
0xFFFFFFFF
FC142
Y Y Y Y
49610
0x2589
Events
FC126
Y Y Y Y
49611
0x258A
Targets
FC101
Y Y Y Y
F0
Analog Input 3
11-96
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
49616
0x258F
Function
FC386
Y Y Y Y
49617
0x2590
Name
65535
F60_26
AnIp 3
13
Y Y Y Y
49630
0x259D
Unit
65535
F60_6
units
Y Y Y Y
49633
0x25A0
Range
FC274
Y Y Y Y
49634
0x25A1
Min Value
-500000
500000
UserF30
Defined
@
Modbus
49630
Y Y Y Y
49636
0x25A3
Max Value
-500000
500000
UserF30
Defined
@
Modbus
49630
Y Y Y Y
49638
0x25A5
Trip Function
FC100D 0
Y Y Y Y
49639
0x25A6
Trip Type
FC275
Y Y Y Y
49640
0x25A7
Trip Pickup
-500000
500000
UserF30
Defined
@
Modbus
49630
20
Y Y Y Y
49642
0x25A9
20
F0
Y Y Y Y
49643
0x25AA
600
F0
Y Y Y Y
49644
0x25AB
600
F0
Y Y Y Y
49645
0x25AC
0xFFFFFFFF
FC198D 0
Y Y Y Y
49647
0x25AE
Alarm Function
FC100E
Y Y Y Y
49648
0x25AF
Alarm Type
FC275
Y Y Y Y
49649
0x25B0
Alarm Pickup
-500000
500000
UserF30
Defined
@
Modbus
49630
10
Y Y Y Y
49651
0x25B2
20
Y Y Y Y
49652
0x25B3
600
F0
Y Y Y Y
49653
0x25B4
600
F0
Y Y Y Y
49654
0x25B5
0xFFFFFFFF
FC198C
Y Y Y Y
49656
0x25B7
Block
0xFFFFFFFF
FC142
Y Y Y Y
49658
0x25B9
Events
FC126
Y Y Y Y
49659
0x25BA
Targets
FC101
Y Y Y Y
F0
Analog Input 4
49664
0x25BF
Function
FC386
Y Y Y Y
49665
0x25C0
Name
65535
F60_26
AnIp 4
13
Y Y Y Y
49678
0x25CD Unit
65535
F60_6
units
Y Y Y Y
49681
0x25D0
Range
FC274
Y Y Y Y
49682
0x25D1
Min Value
-500000
500000
UserF30
Defined
@
Modbus
49678
Y Y Y Y
49684
0x25D3
Max Value
-500000
500000
F30
UserDefined
@
Modbus
49678
Y Y Y Y
11-97
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
49686
0x25D5
Trip Function
FC100D 0
49687
0x25D6
Trip Type
49688
0x25D7
Trip Pickup
-500000
500000
UserF30
Defined
@
Modbus
49678
49690
0x25D9
20
F0
Y Y Y Y
49691
600
F0
Y Y Y Y
F0
FC275
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
1
Y Y Y Y
Y Y Y Y
20
Y Y Y Y
49692
600
Y Y Y Y
49693
0xFFFFFFFF
FC198D 0
Y Y Y Y
49695
0x25DE
Alarm Function
FC100E
Y Y Y Y
49696
0x25DF
Alarm Type
Y Y Y Y
49697
0x25E0
Alarm Pickup
-500000
500000
UserF30
Defined
@
Modbus
49678
10
Y Y Y Y
FC275
49699
0x25E2
20
F0
Y Y Y Y
49700
0x25E3
600
F0
Y Y Y Y
49701
0x25E4
600
F0
Y Y Y Y
49702
0x25E5
0xFFFFFFFF
FC198C
Y Y Y Y
49704
0x25E7
Block
0xFFFFFFFF
FC142
Y Y Y Y
49706
0x25E9
Events
FC126
Y Y Y Y
49707
0x25EA
Targets
FC101
Y Y Y Y
Analog Output 1
50118
0x2785
Function
FC126
Y Y Y Y
50119
0x2786
Range
FC274
Y Y Y Y
50120
0x2787
Parameter
35903
FC273
Y Y Y Y
50121
0x2788
Min Value
-2147483648 2147483647
F30
Y Y Y Y
50123
0x278A
Max Value
-2147483648 2147483647
F30
Y Y Y Y
Function
FC126
Y Y Y Y
Analog Output 2
50129
0x2790
50130
0x2791
Range
FC274
Y Y Y Y
50131
0x2792
Parameter
35903
FC273
Y Y Y Y
50132
0x2793
Min Value
-2147483648 2147483647
F30
Y Y Y Y
50134
0x2795
Max Value
-2147483648 2147483647
F30
Y Y Y Y
Analog Output 3
50140
0x279B
Function
FC126
Y Y Y Y
50141
0x279C
Range
FC274
Y Y Y Y
50142
0x279D
Parameter
35903
FC273
Y Y Y Y
50143
0x279E
Min Value
-2147483648 2147483647
F30
Y Y Y Y
50145
0x27A0
Max Value
-2147483648 2147483647
F30
Y Y Y Y
Analog Output 4
50151
0x27A6
Function
FC126
Y Y Y Y
50152
0x27A7
Range
FC274
Y Y Y Y
50153
0x27A8
Parameter
35903
FC273
Y Y Y Y
50154
0x27A9
Min Value
-2147483648 2147483647
F30
Y Y Y Y
11-98
Modbus Hex
Description
Address Address
Min
50156
-2147483648 2147483647
0x27AB
Max Value
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
F30
Y Y Y Y
Analog Output 5
50162
0x27B1
Function
FC126
Y Y Y Y
50163
0x27B2
Range
FC274
Y Y Y Y
50164
0x27B3
Parameter
35903
FC273
Y Y Y Y
50165
0x27B4
Min Value
-2147483648 2147483647
F30
Y Y Y Y
50167
0x27B6
Max Value
-2147483648 2147483647
F30
Y Y Y Y
Function
FC126
Y Y Y Y
Y Y Y Y
Analog Output 6
50173
0x27BC
50174
0x27BD Range
FC274
50175
0x27BE
Parameter
35903
FC273
Y Y Y Y
50176
0x27BF
Min Value
-2147483648 2147483647
F30
Y Y Y Y
50178
0x27C1
Max Value
-2147483648 2147483647
F30
Y Y Y Y
Analog Output 7
50184
0x27C7
Function
FC126
Y Y Y Y
50185
0x27C8
Range
FC274
Y Y Y Y
50186
0x27C9
Parameter
35903
FC273
Y Y Y Y
50187
0x27CA
Min Value
-2147483648 2147483647
F30
Y Y Y Y
50189
0x27CC
Max Value
-2147483648 2147483647
F30
Y Y Y Y
0x27EB
Trip Function
FC100D 0
Y Y Y Y
50221
0x27EC
Name
65535
F60_26
RTD 1
13
Y Y Y Y
50234
0x27F9
Type
FC120
Y Y Y Y
50235
0x27FA
Application
FC121
Y Y
50236
0x27FB
Voting
18
FC122
Y Y
50237
0x27FC
Trip Temperature
250
?C
F0
155
Y Y Y Y
50238
0x27FD
600
F0
Y Y Y Y
50239
0x27FE
600
F0
Y Y Y Y
50240
0x27FF
Trip Relays
0xFFFFFFFF
FC198D 0
Y Y Y Y
50242
0x2801
Alarm Function
FC100E
Y Y Y Y
50243
0x2802
Alarm Temperature
250
?C
F0
130
Y Y Y Y
50244
0x2803
600
F0
Y Y Y Y
50245
0x2804
600
F0
Y Y Y Y
Y Y Y Y
50246
0x2805
Alarm Relays
0xFFFFFFFF
FC198C
50248
0x2807
Sensor Open
FC354
Y Y Y Y
50249
0x2808
Block
0xFFFFFFFF
FC142
Y Y Y Y
50251
0x280A
Events
FC126
Y Y Y Y
50252
0x280B
Targets
FC101
Y Y Y Y
0x280C
Trip Function
FC100D 0
Y Y Y Y
50254
0x280D
Name
65535
F60_26
RTD 2
13
Y Y Y Y
50267
0x281A
Type
FC120
Y Y Y Y
50268
0x281B
Application
FC121
Y Y
50269
0x281C
Voting
18
FC122
Y Y
50270
0x281D
Trip Temperature
250
F0
155
Y Y Y Y
?C
11-99
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
50271
600
F0
F0
0x281E
Y Y Y Y
50272
0x281F
600
Y Y Y Y
50273
0x2820
Trip Relays
0xFFFFFFFF
FC198D 0
Y Y Y Y
50275
0x2822
Alarm Function
FC100E
Y Y Y Y
50276
0x2823
Alarm Temperature
250
?C
F0
130
Y Y Y Y
50277
0x2824
600
F0
Y Y Y Y
50278
0x2825
600
F0
Y Y Y Y
50279
0x2826
Alarm Relays
0xFFFFFFFF
FC198C
Y Y Y Y
50281
0x2828
Sensor Open
FC354
Y Y Y Y
50282
0x2829
Block
0xFFFFFFFF
FC142
Y Y Y Y
50284
0x282B
Events
FC126
Y Y Y Y
50285
0x282C
Targets
FC101
Y Y Y Y
0x282D
Trip Function
FC100D 0
Y Y Y Y
50287
0x282E
Name
65535
F60_26
RTD 3
13
Y Y Y Y
50300
0x283B
Type
FC120
Y Y Y Y
50301
0x283C
Application
FC121
Y Y
50302
0x283D
Voting
18
FC122
Y Y
50303
0x283E
Trip Temperature
250
?C
F0
155
Y Y Y Y
50304
0x283F
600
F0
Y Y Y Y
F0
50305
0x2840
600
50306
0x2841
Trip Relays
0xFFFFFFFF
50308
0x2843
Alarm Function
50309
0x2844
Alarm Temperature
250
?C
50310
0x2845
600
s
s
Y Y Y Y
FC198D 0
Y Y Y Y
FC100E
Y Y Y Y
F0
130
Y Y Y Y
F0
Y Y Y Y
50311
0x2846
600
F0
Y Y Y Y
50312
0x2847
Alarm Relays
0xFFFFFFFF
FC198C
Y Y Y Y
50314
0x2849
Sensor Open
FC354
Y Y Y Y
50315
0x284A
Block
0xFFFFFFFF
FC142
Y Y Y Y
50317
0x284C
Events
FC126
Y Y Y Y
50318
0x284D
Targets
FC101
Y Y Y Y
0x284E
Trip Function
FC100D 0
Y Y Y Y
50320
0x284F
Name
65535
F60_26
RTD 4
13
Y Y Y Y
50333
0x285C
Type
FC120
Y Y Y Y
50334
0x285D
Application
FC121
Y Y
50335
0x285E
Voting
18
FC122
Y Y
50336
0x285F
Trip Temperature
250
?C
F0
155
Y Y Y Y
50337
0x2860
600
F0
Y Y Y Y
50338
0x2861
600
F0
Y Y Y Y
50339
0x2862
Trip Relays
0xFFFFFFFF
FC198D 0
Y Y Y Y
50341
0x2864
Alarm Function
FC100E
Y Y Y Y
50342
0x2865
Alarm Temperature
250
?C
F0
130
Y Y Y Y
50343
0x2866
600
F0
Y Y Y Y
50344
0x2867
600
F0
Y Y Y Y
11-100
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
50345
Alarm Relays
0xFFFFFFFF
FC198C
0x2868
Y Y Y Y
50347
0x286A
Sensor Open
FC354
Y Y Y Y
50348
0x286B
Block
0xFFFFFFFF
FC142
Y Y Y Y
50350
0x286D
Events
FC126
Y Y Y Y
50351
0x286E
Targets
FC101
Y Y Y Y
0x286F
Trip Function
FC100D 0
Y Y Y Y
50353
0x2870
Name
65535
F60_26
RTD 5
13
Y Y Y Y
50366
0x287D
Type
FC120
Y Y Y Y
50367
0x287E
Application
FC121
Y Y
50368
0x287F
Voting
18
FC122
Y Y
50369
0x2880
Trip Temperature
250
F0
155
Y Y Y Y
50370
0x2881
600
F0
Y Y Y Y
50371
0x2882
600
F0
Y Y Y Y
50372
0x2883
Trip Relays
0xFFFFFFFF
FC198D 0
Y Y Y Y
50374
0x2885
Alarm Function
FC100E
Y Y Y Y
50375
0x2886
Alarm Temperature
250
F0
130
Y Y Y Y
50376
0x2887
600
F0
Y Y Y Y
50377
0x2888
600
F0
Y Y Y Y
50378
0x2889
Alarm Relays
0xFFFFFFFF
FC198C
Y Y Y Y
?C
?C
50380
0x288B
Sensor Open
FC354
Y Y Y Y
50381
0x288C
Block
0xFFFFFFFF
FC142
Y Y Y Y
50383
0x288E
Events
FC126
Y Y Y Y
50384
0x288F
Targets
FC101
Y Y Y Y
0x2890
Trip Function
FC100D 0
Y Y Y Y
50386
0x2891
Name
65535
F60_26
RTD 6
13
Y Y Y Y
50399
0x289E
Type
FC120
Y Y Y Y
50400
0x289F
Application
FC121
Y Y
50401
0x28A0
Voting
18
FC122
Y Y
50402
0x28A1
Trip Temperature
250
?C
F0
155
Y Y Y Y
50403
0x28A2
600
F0
Y Y Y Y
50404
0x28A3
600
F0
Y Y Y Y
50405
0x28A4
Trip Relays
0xFFFFFFFF
FC198D 0
Y Y Y Y
50407
0x28A6
Alarm Function
FC100E
Y Y Y Y
50408
0x28A7
Alarm Temperature
250
F0
130
Y Y Y Y
50409
0x28A8
600
F0
Y Y Y Y
50410
0x28A9
600
F0
Y Y Y Y
Y Y Y Y
?C
50411
0x28AA
Alarm Relays
0xFFFFFFFF
FC198C
50413
0x28AC
Sensor Open
FC354
Y Y Y Y
50414
0x28AD Block
0xFFFFFFFF
FC142
Y Y Y Y
50416
0x28AF
Events
FC126
Y Y Y Y
50417
0x28B0
Targets
FC101
Y Y Y Y
FC100D 0
Y Y Y Y
0x28B1
Trip Function
11-101
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
50419
0x28B2
Name
65535
F60_26
RTD 7
13
Y Y Y Y
50432
0x28BF
Type
FC120
Y Y Y Y
50433
0x28C0
Application
FC121
Y Y
50434
0x28C1
Voting
18
FC122
Y Y
50435
0x28C2
Trip Temperature
250
?C
F0
155
Y Y Y Y
50436
0x28C3
600
F0
Y Y Y Y
F0
50437
0x28C4
600
Y Y Y Y
50438
0x28C5
Trip Relays
0xFFFFFFFF
FC198D 0
Y Y Y Y
50440
0x28C7
Alarm Function
FC100E
Y Y Y Y
50441
0x28C8
Alarm Temperature
250
?C
F0
130
Y Y Y Y
50442
0x28C9
600
F0
Y Y Y Y
50443
0x28CA
600
F0
Y Y Y Y
50444
0x28CB
Alarm Relays
0xFFFFFFFF
FC198C
Y Y Y Y
50446
FC354
Y Y Y Y
50447
0x28CE
Block
0xFFFFFFFF
FC142
Y Y Y Y
50449
0x28D0
Events
FC126
Y Y Y Y
50450
0x28D1
Targets
FC101
Y Y Y Y
0x28D2
Trip Function
FC100D 0
Y Y Y Y
50452
0x28D3
Name
65535
F60_26
13
Y Y Y Y
RTD 8
50465
0x28E0
Type
FC120
Y Y Y Y
50466
0x28E1
Application
FC121
Y Y
50467
0x28E2
Voting
18
FC122
Y Y
50468
0x28E3
Trip Temperature
250
?C
F0
155
Y Y Y Y
50469
0x28E4
600
F0
Y Y Y Y
F0
50470
0x28E5
600
Y Y Y Y
50471
0x28E6
Trip Relays
0xFFFFFFFF
FC198D 0
Y Y Y Y
50473
0x28E8
Alarm Function
FC100E
Y Y Y Y
50474
0x28E9
Alarm Temperature
250
?C
F0
130
Y Y Y Y
50475
0x28EA
600
F0
Y Y Y Y
50476
0x28EB
600
F0
Y Y Y Y
50477
0x28EC
Alarm Relays
0xFFFFFFFF
FC198C
Y Y Y Y
50479
0x28EE
Sensor Open
FC354
Y Y Y Y
50480
0x28EF
Block
0xFFFFFFFF
FC142
Y Y Y Y
50482
0x28F1
Events
FC126
Y Y Y Y
50483
0x28F2
Targets
FC101
Y Y Y Y
FC100D 0
Y Y Y Y
0x28F3
Trip Function
50485
0x28F4
Name
65535
F60_26
RTD 9
13
Y Y Y Y
50498
0x2901
Type
FC120
Y Y Y Y
50499
0x2902
Application
FC121
Y Y
50500
0x2903
Voting
18
FC122
Y Y
50501
0x2904
Trip Temperature
250
?C
F0
155
Y Y Y Y
50502
0x2905
600
F0
Y Y Y Y
50503
0x2906
600
F0
Y Y Y Y
11-102
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
50504
0x2907
Trip Relays
0xFFFFFFFF
FC198D 0
Y Y Y Y
50506
0x2909
Alarm Function
FC100E
Y Y Y Y
50507
0x290A
Alarm Temperature
250
?C
F0
130
Y Y Y Y
50508
0x290B
600
F0
Y Y Y Y
50509
0x290C
600
50510
0x290D
Alarm Relays
0xFFFFFFFF
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
F0
Y Y Y Y
FC198C
Y Y Y Y
50512
0x290F
Sensor Open
FC354
Y Y Y Y
50513
0x2910
Block
0xFFFFFFFF
FC142
Y Y Y Y
50515
0x2912
Events
FC126
Y Y Y Y
50516
0x2913
Targets
FC101
Y Y Y Y
0x2914
Trip Function
FC100D 0
Y Y Y Y
50518
0x2915
Name
65535
F60_26
RTD 10
13
Y Y Y Y
50531
0x2922
Type
FC120
Y Y Y Y
50532
0x2923
Application
FC121
Y Y
50533
0x2924
Voting
18
FC122
Y Y
50534
0x2925
Trip Temperature
250
F0
155
Y Y Y Y
50535
0x2926
600
F0
Y Y Y Y
50536
0x2927
600
F0
Y Y Y Y
50537
0x2928
Trip Relays
0xFFFFFFFF
FC198D 0
Y Y Y Y
50539
0x292A
Alarm Function
FC100E
Y Y Y Y
50540
0x292B
Alarm Temperature
250
F0
130
Y Y Y Y
50541
0x292C
600
F0
Y Y Y Y
50542
0x292D
600
F0
Y Y Y Y
50543
0x292E
Alarm Relays
0xFFFFFFFF
FC198C
Y Y Y Y
?C
?C
50545
0x2930
Sensor Open
FC354
Y Y Y Y
50546
0x2931
Block
0xFFFFFFFF
FC142
Y Y Y Y
50548
0x2933
Events
FC126
Y Y Y Y
50549
0x2934
Targets
FC101
Y Y Y Y
0x2935
Trip Function
FC100D 0
Y Y Y Y
50551
0x2936
Name
65535
F60_26
RTD 11
13
Y Y Y Y
50564
0x2943
Type
FC120
Y Y Y Y
50565
0x2944
Application
FC121
Y Y
50566
0x2945
Voting
18
FC122
Y Y
50567
0x2946
Trip Temperature
250
F0
155
Y Y Y Y
50568
0x2947
600
F0
Y Y Y Y
50569
0x2948
600
F0
Y Y Y Y
50570
0x2949
Trip Relays
0xFFFFFFFF
FC198D 0
Y Y Y Y
50572
0x294B
Alarm Function
FC100E
Y Y Y Y
50573
0x294C
Alarm Temperature
250
F0
130
Y Y Y Y
50574
0x294D
600
F0
Y Y Y Y
50575
0x294E
600
F0
Y Y Y Y
50576
0x294F
Alarm Relays
0xFFFFFFFF
FC198C
Y Y Y Y
50578
0x2951
Sensor Open
FC354
Y Y Y Y
?C
?C
11-103
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
50579
Block
0xFFFFFFFF
FC142
0x2952
Y Y Y Y
50581
0x2954
Events
FC126
Y Y Y Y
50582
0x2955
Targets
FC101
Y Y Y Y
0x2956
Trip Function
FC100D 0
Y Y Y Y
50584
0x2957
Name
65535
F60_26
RTD 12
13
Y Y Y Y
50597
0x2964
Type
FC120
Y Y Y Y
50598
0x2965
Application
FC121
Y Y
50599
0x2966
Voting
18
FC122
Y Y
50600
0x2967
Trip Temperature
250
?C
F0
155
Y Y Y Y
50601
0x2968
600
F0
Y Y Y Y
50602
0x2969
600
F0
Y Y Y Y
50603
0x296A
Trip Relays
0xFFFFFFFF
FC198D 0
Y Y Y Y
50605
0x296C
Alarm Function
FC100E
Y Y Y Y
50606
0x296D
Alarm Temperature
250
?C
F0
130
Y Y Y Y
50607
0x296E
600
F0
Y Y Y Y
50608
0x296F
600
F0
Y Y Y Y
50609
0x2970
Alarm Relays
0xFFFFFFFF
FC198C
Y Y Y Y
50611
0x2972
Sensor Open
FC354
Y Y Y Y
50612
0x2973
Block
0xFFFFFFFF
FC142
Y Y Y Y
50614
0x2975
Events
FC126
Y Y Y Y
50615
0x2976
Targets
FC101
Y Y Y Y
0x2977
Trip Function
FC100D 0
Y Y Y Y
50617
0x2978
Name
65535
F60_26
RTD 13
13
Y Y Y Y
50630
0x2985
Type
FC120
Y Y Y Y
50631
0x2986
Application
FC121
Y Y
50632
0x2987
Voting
18
FC122
Y Y
50633
0x2988
Trip Temperature
250
?C
F0
155
Y Y Y Y
50634
0x2989
600
F0
Y Y Y Y
F0
50635
0x298A
600
Y Y Y Y
50636
0x298B
Trip Relays
0xFFFFFFFF
FC198D 0
Y Y Y Y
50638
0x298D
Alarm Function
FC100E
Y Y Y Y
50639
0x298E
Alarm Temperature
250
?C
F0
130
Y Y Y Y
50640
0x298F
600
F0
Y Y Y Y
50641
0x2990
600
F0
Y Y Y Y
50642
0x2991
Alarm Relays
0xFFFFFFFF
FC198C
Y Y Y Y
50644
0x2993
Sensor Open
FC354
Y Y Y Y
50645
0x2994
Block
0xFFFFFFFF
FC142
Y Y Y Y
50647
0x2996
Events
FC126
Y Y Y Y
50648
0x2997
Targets
FC101
Y Y Y Y
FC324
Y Y Y Y
65535
F60_80
Filename
40
Y Y Y Y
0x30FF
Transfer Mode
11-104
0x3100
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
0x3200
4294967295
F10
52803
0x3202
65535
F0
Y Y Y Y
52804
0x3203
DataBlock 0
65535
F0
Y Y Y Y
52805
0x3204
DataBlock 1
65535
F0
Y Y Y Y
52806
0x3205
DataBlock 2
65535
F0
Y Y Y Y
52807
0x3206
DataBlock 3
65535
F0
Y Y Y Y
52808
0x3207
DataBlock 4
65535
F0
Y Y Y Y
52809
0x3208
DataBlock 5
65535
F0
Y Y Y Y
52810
0x3209
DataBlock 6
65535
F0
Y Y Y Y
52811
0x320A
DataBlock 7
65535
F0
Y Y Y Y
52812
0x320B
DataBlock 8
65535
F0
Y Y Y Y
52813
0x320C
DataBlock 9
65535
F0
Y Y Y Y
52814
0x320D
DataBlock 10
65535
F0
Y Y Y Y
52815
0x320E
DataBlock 11
65535
F0
Y Y Y Y
52816
0x320F
DataBlock 12
65535
F0
Y Y Y Y
52817
0x3210
DataBlock 13
65535
F0
Y Y Y Y
52818
0x3211
DataBlock 14
65535
F0
Y Y Y Y
52819
0x3212
DataBlock 15
65535
F0
Y Y Y Y
52820
0x3213
DataBlock 16
65535
F0
Y Y Y Y
52821
0x3214
DataBlock 17
65535
F0
Y Y Y Y
52822
0x3215
DataBlock 18
65535
F0
Y Y Y Y
52823
0x3216
DataBlock 19
65535
F0
Y Y Y Y
52824
0x3217
DataBlock 20
65535
F0
Y Y Y Y
52825
0x3218
DataBlock 21
65535
F0
Y Y Y Y
52826
0x3219
DataBlock 22
65535
F0
Y Y Y Y
52827
0x321A
DataBlock 23
65535
F0
Y Y Y Y
52828
0x321B
DataBlock 24
65535
F0
Y Y Y Y
52829
0x321C
DataBlock 25
65535
F0
Y Y Y Y
52830
0x321D
DataBlock 26
65535
F0
Y Y Y Y
52831
0x321E
DataBlock 27
65535
F0
Y Y Y Y
52832
0x321F
DataBlock 28
65535
F0
Y Y Y Y
52833
0x3220
DataBlock 29
65535
F0
Y Y Y Y
52834
0x3221
DataBlock 30
65535
F0
Y Y Y Y
52835
0x3222
DataBlock 31
65535
F0
Y Y Y Y
52836
0x3223
DataBlock 32
65535
F0
Y Y Y Y
52837
0x3224
DataBlock 33
65535
F0
Y Y Y Y
52838
0x3225
DataBlock 34
65535
F0
Y Y Y Y
52839
0x3226
DataBlock 35
65535
F0
Y Y Y Y
52840
0x3227
DataBlock 36
65535
F0
Y Y Y Y
52841
0x3228
DataBlock 37
65535
F0
Y Y Y Y
52842
0x3229
DataBlock 38
65535
F0
Y Y Y Y
52843
0x322A
DataBlock 39
65535
F0
Y Y Y Y
52844
0x322B
DataBlock 40
65535
F0
Y Y Y Y
52845
0x322C
DataBlock 41
65535
F0
Y Y Y Y
Y Y Y Y
11-105
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
52846
0x322D
65535
F0
52847
0x322E
DataBlock 43
65535
F0
Y Y Y Y
52848
0x322F
DataBlock 44
65535
F0
Y Y Y Y
52849
0x3230
DataBlock 45
65535
F0
Y Y Y Y
52850
0x3231
DataBlock 46
65535
F0
Y Y Y Y
52851
0x3232
DataBlock 47
65535
F0
Y Y Y Y
52852
0x3233
DataBlock 48
65535
F0
Y Y Y Y
52853
0x3234
DataBlock 49
65535
F0
Y Y Y Y
52854
0x3235
DataBlock 50
65535
F0
Y Y Y Y
52855
0x3236
DataBlock 51
65535
F0
Y Y Y Y
52856
0x3237
DataBlock 52
65535
F0
Y Y Y Y
52857
0x3238
DataBlock 53
65535
F0
Y Y Y Y
52858
0x3239
DataBlock 54
65535
F0
Y Y Y Y
52859
0x323A
DataBlock 55
65535
F0
Y Y Y Y
52860
0x323B
DataBlock 56
65535
F0
Y Y Y Y
52861
0x323C
DataBlock 57
65535
F0
Y Y Y Y
52862
0x323D
DataBlock 58
65535
F0
Y Y Y Y
52863
0x323E
DataBlock 59
65535
F0
Y Y Y Y
52864
0x323F
DataBlock 60
65535
F0
Y Y Y Y
52865
0x3240
DataBlock 61
65535
F0
Y Y Y Y
52866
0x3241
DataBlock 62
65535
F0
Y Y Y Y
52867
0x3242
DataBlock 63
65535
F0
Y Y Y Y
52868
0x3243
DataBlock 64
65535
F0
Y Y Y Y
52869
0x3244
DataBlock 65
65535
F0
Y Y Y Y
52870
0x3245
DataBlock 66
65535
F0
Y Y Y Y
52871
0x3246
DataBlock 67
65535
F0
Y Y Y Y
52872
0x3247
DataBlock 68
65535
F0
Y Y Y Y
52873
0x3248
DataBlock 69
65535
F0
Y Y Y Y
52874
0x3249
DataBlock 70
65535
F0
Y Y Y Y
52875
0x324A
DataBlock 71
65535
F0
Y Y Y Y
52876
0x324B
DataBlock 72
65535
F0
Y Y Y Y
52877
0x324C
DataBlock 73
65535
F0
Y Y Y Y
52878
0x324D
DataBlock 74
65535
F0
Y Y Y Y
52879
0x324E
DataBlock 75
65535
F0
Y Y Y Y
52880
0x324F
DataBlock 76
65535
F0
Y Y Y Y
52881
0x3250
DataBlock 77
65535
F0
Y Y Y Y
52882
0x3251
DataBlock 78
65535
F0
Y Y Y Y
52883
0x3252
DataBlock 79
65535
F0
Y Y Y Y
52884
0x3253
DataBlock 80
65535
F0
Y Y Y Y
52885
0x3254
DataBlock 81
65535
F0
Y Y Y Y
52886
0x3255
DataBlock 82
65535
F0
Y Y Y Y
52887
0x3256
DataBlock 83
65535
F0
Y Y Y Y
52888
0x3257
DataBlock 84
65535
F0
Y Y Y Y
52889
0x3258
DataBlock 85
65535
F0
Y Y Y Y
52890
0x3259
DataBlock 86
65535
F0
Y Y Y Y
11-106
DataBlock 42
Y Y Y Y
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
52891
0x325A
65535
F0
52892
0x325B
DataBlock 88
65535
F0
Y Y Y Y
52893
0x325C
DataBlock 89
65535
F0
Y Y Y Y
52894
0x325D
DataBlock 90
65535
F0
Y Y Y Y
52895
0x325E
DataBlock 91
65535
F0
Y Y Y Y
52896
0x325F
DataBlock 92
65535
F0
Y Y Y Y
52897
0x3260
DataBlock 93
65535
F0
Y Y Y Y
52898
0x3261
DataBlock 94
65535
F0
Y Y Y Y
52899
0x3262
DataBlock 95
65535
F0
Y Y Y Y
52900
0x3263
DataBlock 96
65535
F0
Y Y Y Y
52901
0x3264
DataBlock 97
65535
F0
Y Y Y Y
52902
0x3265
DataBlock 98
65535
F0
Y Y Y Y
52903
0x3266
DataBlock 99
65535
F0
Y Y Y Y
52904
0x3267
DataBlock 100
65535
F0
Y Y Y Y
52905
0x3268
DataBlock 101
65535
F0
Y Y Y Y
52906
0x3269
DataBlock 102
65535
F0
Y Y Y Y
52907
0x326A
DataBlock 103
65535
F0
Y Y Y Y
52908
0x326B
DataBlock 104
65535
F0
Y Y Y Y
52909
0x326C
DataBlock 105
65535
F0
Y Y Y Y
52910
0x326D
DataBlock 106
65535
F0
Y Y Y Y
52911
0x326E
DataBlock 107
65535
F0
Y Y Y Y
52912
0x326F
DataBlock 108
65535
F0
Y Y Y Y
52913
0x3270
DataBlock 109
65535
F0
Y Y Y Y
52914
0x3271
DataBlock 110
65535
F0
Y Y Y Y
52915
0x3272
DataBlock 111
65535
F0
Y Y Y Y
52916
0x3273
DataBlock 112
65535
F0
Y Y Y Y
52917
0x3274
DataBlock 113
65535
F0
Y Y Y Y
52918
0x3275
DataBlock 114
65535
F0
Y Y Y Y
52919
0x3276
DataBlock 115
65535
F0
Y Y Y Y
52920
0x3277
DataBlock 116
65535
F0
Y Y Y Y
52921
0x3278
DataBlock 117
65535
F0
Y Y Y Y
52922
0x3279
DataBlock 118
65535
F0
Y Y Y Y
52923
0x327A
DataBlock 119
65535
F0
Y Y Y Y
52924
0x327B
DataBlock 120
65535
F0
Y Y Y Y
52925
0x327C
DataBlock 121
65535
F0
Y Y Y Y
DataBlock 87
Y Y Y Y
Security
53020
0x32DB Login
FC252
Y Y Y Y
53021
0x32DC Logout
FC126B
Y Y Y Y
53022
FC126
Y Y Y Y
53023
0x32DE
FC126B
Y Y Y Y
53024
0x32DF
Access Lockout
99
F0
Y Y Y Y
53025
0x32E0
9999
min
F0
Y Y Y Y
53026
0x32E1
Access Timeout
999
min
F0
Y Y Y Y
53027
0x32E2
Password Complexity
FC126
Y Y Y Y
53028
0x32E3
Setpoint Access
0xFFFFFFFF
FC142
Y Y Y Y
11-107
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
53030
Device Authentication
FC126B
Y Y Y Y
65535
F60_22
11
Y Y Y Y
0x32E5
Security Passwords
53040
0x32EF
Supervisory Settings
53191
0x3386
Lock Relay
FC126
Y Y Y Y
53192
0x3387
Administrator Forced
Logout
FC126B
Y Y Y Y
53193
0x3388
FC126B
Y Y Y Y
53194
0x3389
FC126B
Y Y Y Y
Security - Radius
53290
0x33E9
0xDFFFFFFE
F70
Y Y Y Y
53293
0x33EC
65535
F0
Y Y Y Y
53294
0x33ED
Vendor ID
65535
F0
2910
Y Y Y Y
53295
0x33EE
Radius Authentication
Method
FC341
Y Y Y Y
53296
0x33EF
Timeout
9999
F0
10
Y Y Y Y
53297
0x33F0
Retries
9999
F0
Y Y Y Y
Modbus Protocol
53540
0x34E3
254
F0
254
Y Y Y Y
53541
0x34E4
65535
F0
502
Y Y Y Y
RS485 Port 1
53560
0x34F7
Baud Rate
FC210
Y Y Y Y
53561
0x34F8
Parity
FC211
Y Y Y Y
53562
0x34F9
Port Protocol
FC209
Y Y Y Y
53610
0x3529
WiFi Enable
FC126
Y Y Y Y
53611
0x352A
WiFi IP Address
0xFFFFFFFF
F70
0xC0A800 2
02
Y Y Y Y
53613
0x352C
0xFFFFFFFF
F70
0xFFFFFF0 2
0
Y Y Y Y
53615
0x352E
0xFFFFFFFF
F70
0xC0A800 2
01
Y Y Y Y
53617
0x3530
WiFi Security
FC226
Y Y Y Y
53618
0x3531
WiFi SSID
65535
F60_14
GEMULTILI 7
N
Y Y Y Y
53640
0x3547
65535
F60_14
Ge1wx9s3 7
123!4
Y Y Y Y
WiFi
Ethernet Port 1
53660
0x355B
PRT1 IP Address
0xFFFFFFFF
F70
0xA9FE03 2
03
Y Y Y Y
53662
0x355D
0xFFFFFFFF
F70
0xFFFFFF0 2
0
Y Y Y Y
53664
0x355F
0xFFFFFFFF
F70
0xA9FE03 2
01
Y Y Y Y
53666
0x3561
PRT4 IP Address
0xFFFFFFFF
F70
0x7F0000 2
01
Y Y Y Y
53668
0x3563
0xFFFFFFFF
F70
Y Y Y Y
53670
0x3565
0xFFFFFFFF
F70
Y Y Y Y
53672
0x3567
PRT4 Operation
FC219
Y Y Y Y
11-108
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
53674
0x3569
PRT5 IP Address
0xFFFFFFFF
F70
0x7F0000 2
01
53676
0x356B
0xFFFFFFFF
F70
Y Y Y Y
53678
0x356D
0xFFFFFFFF
F70
Y Y Y Y
Gateway Address
0xDFFFFFFE
F70
0x7F0000 2
01
Y Y Y Y
Y Y Y Y
Default Route
53700
0x3583
Static RT 1
53702
0x3585
RT1 Destination
0xDFFFFFFE
F70
0x7F0000 2
01
Y Y Y Y
53704
0x3587
RT1 Mask
0xFFFFFFFF
F70
0xFF0000 2
00
Y Y Y Y
53706
0x3589
RT1 Gateway
0xDFFFFFFE
F70
0x7F0000 2
01
Y Y Y Y
Static RT 2
53708
0x358B
RT2 Destination
0xDFFFFFFE
F70
0x7F0000 2
01
Y Y Y Y
53710
0x358D
RT2 Mask
0xFFFFFFFF
F70
0xFF0000 2
00
Y Y Y Y
53712
0x358F
RT2 Gateway
0xDFFFFFFE
F70
0x7F0000 2
01
Y Y Y Y
Static RT 3
53714
0x3591
RT3 Destination
0xDFFFFFFE
F70
0x7F0000 2
01
Y Y Y Y
53716
0x3593
RT3 Mask
0xFFFFFFFF
F70
0xFF0000 2
00
Y Y Y Y
53718
0x3595
RT3 Gateway
0xDFFFFFFE
F70
0x7F0000 2
01
Y Y Y Y
Static RT 4
53720
0x3597
RT4 Destination
0xDFFFFFFE
F70
0x7F0000 2
01
Y Y Y Y
53722
0x3599
RT4 Mask
0xFFFFFFFF
F70
0xFF0000 2
00
Y Y Y Y
53724
0x359B
RT4 Gateway
0xDFFFFFFE
F70
0x7F0000 2
01
Y Y Y Y
Static RT 5
53726
0x359D
RT5 Destination
0xDFFFFFFE
F70
0x7F0000 2
01
Y Y Y Y
53728
0x359F
RT5 Mask
0xFFFFFFFF
F70
0xFF0000 2
00
Y Y Y Y
53730
0x35A1
RT5 Gateway
0xDFFFFFFE
F70
0x7F0000 2
01
Y Y Y Y
Static RT 6
53732
0x35A3
RT6 Destination
0xDFFFFFFE
F70
0x7F0000 2
01
Y Y Y Y
53734
0x35A5
RT6 Mask
0xFFFFFFFF
F70
0xFF0000 2
00
Y Y Y Y
53736
0x35A7
RT6 Gateway
0xDFFFFFFE
F70
0x7F0000 2
01
Y Y Y Y
DNP Protocol
53740
0x35AB
FC239
Y Y Y Y
53741
0x35AC
FC239
Y Y Y Y
53742
65519
F0
65519
Y Y Y Y
11-109
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
53743
0x35AE
0xFFFFFFFF
F70
Y Y Y Y
53745
0x35B0
0xFFFFFFFF
F70
Y Y Y Y
53747
0x35B2
65535
F0
20000
Y Y Y Y
53748
0x35B3
65535
F0
20000
Y Y Y Y
53749
0x35B4
53750
0x35B5
60
FC126
Y Y Y Y
F0
Y Y Y Y
53751
0x35B6
255
F0
10
Y Y Y Y
53752
0x35B7
65519
F0
Y Y Y Y
53753
0x35B8
10080
F0
1440
Y Y Y Y
53754
0x35B9
2048
F0
240
Y Y Y Y
53755
0x35BA
FC231
Y Y Y Y
53756
0x35BB
FC232
Y Y Y Y
53757
0x35BC
Object 20 Default
Variation
FC233
Y Y Y Y
53758
10
FC234
Y Y Y Y
53759
0x35BE
Object 22 Default
Variation
FC235
Y Y Y Y
53760
0x35BF
Object 23 Default
Variation
FC236
Y Y Y Y
53761
0x35C0
Object 30 Default
Variation
FC237
Y Y Y Y
53762
0x35C1
Object 32 Default
Variation
FC238
Y Y Y Y
53763
0x35C2
10
300
F0
120
Y Y Y Y
30
min
0x35D3
Point 0 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53782
0x35D5
Point 1 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53784
0x35D7
Point 2 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53786
0x35D9
Point 3 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53788
0xFFFFFFFF
FC142
Y Y Y Y
53790
0xFFFFFFFF
FC142
Y Y Y Y
53792
0x35DF
Point 6 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53794
0x35E1
Point 7 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53796
0x35E3
Point 8 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53798
0x35E5
Point 9 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53800
0x35E7
Point 10 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53802
0x35E9
Point 11 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53804
0x35EB
Point 12 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53806
0x35ED
Point 13 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53808
0x35EF
Point 14 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53810
0x35F1
Point 15 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53812
0x35F3
Point 16 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53814
0x35F5
Point 17 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53816
0x35F7
Point 18 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53818
0x35F9
Point 19 Entry
0xFFFFFFFF
FC142
Y Y Y Y
11-110
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
53820
0x35FB
0xFFFFFFFF
FC142
53822
0x35FD
Point 21 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53824
0x35FF
Point 22 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53826
0x3601
Point 23 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53828
0x3603
Point 24 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53830
0x3605
Point 25 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53832
0x3607
Point 26 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53834
0x3609
Point 27 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53836
0x360B
Point 28 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53838
0x360D
Point 29 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53840
0x360F
Point 30 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53842
0x3611
Point 31 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53844
0x3613
Point 32 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53846
0x3615
Point 33 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53848
0x3617
Point 34 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53850
0x3619
Point 35 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53852
0x361B
Point 36 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53854
0x361D
Point 37 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53856
0x361F
Point 38 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53858
0x3621
Point 39 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53860
0x3623
Point 40 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53862
0x3625
Point 41 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53864
0x3627
Point 42 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53866
0x3629
Point 43 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53868
0x362B
Point 44 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53870
0x362D
Point 45 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53872
0x362F
Point 46 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53874
0x3631
Point 47 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53876
0x3633
Point 48 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53878
0x3635
Point 49 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53880
0x3637
Point 50 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53882
0x3639
Point 51 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53884
0x363B
Point 52 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53886
0x363D
Point 53 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53888
0x363F
Point 54 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53890
0x3641
Point 55 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53892
0x3643
Point 56 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53894
0x3645
Point 57 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53896
0x3647
Point 58 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53898
0x3649
Point 59 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53900
0x364B
Point 60 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53902
0x364D
Point 61 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53904
0x364F
Point 62 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53906
0x3651
Point 63 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53908
0x3653
Point 64 Entry
0xFFFFFFFF
FC142
Y Y Y Y
Point 20 Entry
Y Y Y Y
11-111
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
53910
0x3655
Point 65 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53912
0x3657
Point 66 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53914
0x3659
Point 67 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53916
0x365B
Point 68 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53918
0x365D
Point 69 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53920
0x365F
Point 70 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53922
0x3661
Point 71 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53924
0x3663
Point 72 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53926
0x3665
Point 73 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53928
0x3667
Point 74 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53930
0x3669
Point 75 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53932
0x366B
Point 76 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53934
0x366D
Point 77 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53936
0x366F
Point 78 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53938
0x3671
Point 79 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53940
0x3673
Point 80 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53942
0x3675
Point 81 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53944
0x3677
Point 82 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53946
0x3679
Point 83 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53948
0x367B
Point 84 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53950
0x367D
Point 85 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53952
0x367F
Point 86 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53954
0x3681
Point 87 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53956
0x3683
Point 88 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53958
0x3685
Point 89 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53960
0x3687
Point 90 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53962
0x3689
Point 91 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53964
0x368B
Point 92 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53966
0x368D
Point 93 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53968
0x368F
Point 94 Entry
0xFFFFFFFF
FC142
Y Y Y Y
53970
0x3691
Point 95 Entry
0xFFFFFFFF
FC142
Y Y Y Y
35903
FC273
Y Y Y Y
0x36A5
53991
0x36A6
FC229
Y Y Y Y
53992
0x36A7
Point 0 Deadband
100000000
F10
30000
Y Y Y Y
0x36A9
35903
FC273
Y Y Y Y
53995
0x36AA
FC229
Y Y Y Y
53996
0x36AB
Point 1 Deadband
100000000
F10
30000
Y Y Y Y
35903
FC273
Y Y Y Y
53999
0x36AE
FC229
Y Y Y Y
54000
0x36AF
Point 2 Deadband
100000000
F10
30000
Y Y Y Y
35903
FC273
Y Y Y Y
11-112
0x36B1
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
54003
0x36B2
FC229
Y Y Y Y
54004
0x36B3
Point 3 Deadband
100000000
F10
30000
Y Y Y Y
35903
FC273
Y Y Y Y
0x36B5
54007
0x36B6
FC229
Y Y Y Y
54008
0x36B7
Point 4 Deadband
100000000
F10
30000
Y Y Y Y
0x36B9
35903
FC273
Y Y Y Y
54011
0x36BA
FC229
Y Y Y Y
54012
0x36BB
Point 5 Deadband
100000000
F10
30000
Y Y Y Y
35903
FC273
Y Y Y Y
54015
0x36BE
FC229
Y Y Y Y
54016
0x36BF
Point 6 Deadband
100000000
F10
30000
Y Y Y Y
0x36C1
35903
FC273
Y Y Y Y
54019
0x36C2
FC229
Y Y Y Y
54020
0x36C3
Point 7 Deadband
100000000
F10
30000
Y Y Y Y
35903
FC273
Y Y Y Y
0x36C5
54023
0x36C6
FC229
Y Y Y Y
54024
0x36C7
Point 8 Deadband
100000000
F10
30000
Y Y Y Y
0x36C9
35903
FC273
Y Y Y Y
54027
0x36CA
FC229
Y Y Y Y
54028
0x36CB
Point 9 Deadband
100000000
F10
30000
Y Y Y Y
35903
FC273
Y Y Y Y
54031
0x36CE
FC229
Y Y Y Y
54032
0x36CF
Point 10 Deadband
100000000
F10
30000
Y Y Y Y
0x36D1
35903
FC273
Y Y Y Y
54035
0x36D2
FC229
Y Y Y Y
54036
0x36D3
Point 11 Deadband
100000000
F10
30000
Y Y Y Y
35903
FC273
Y Y Y Y
0x36D5
54039
0x36D6
FC229
Y Y Y Y
54040
0x36D7
Point 12 Deadband
100000000
F10
30000
Y Y Y Y
0x36D9
35903
FC273
Y Y Y Y
54043
FC229
Y Y Y Y
54044
100000000
F10
30000
Y Y Y Y
35903
FC273
Y Y Y Y
54047
0x36DE
FC229
Y Y Y Y
11-113
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
54048
100000000
F10
30000
Y Y Y Y
0x36DF
Point 14 Deadband
0x36E1
35903
FC273
Y Y Y Y
54051
0x36E2
FC229
Y Y Y Y
54052
0x36E3
Point 15 Deadband
100000000
F10
30000
Y Y Y Y
Y Y Y Y
0x36E5
35903
FC273
54055
0x36E6
FC229
Y Y Y Y
54056
0x36E7
Point 16 Deadband
100000000
F10
30000
Y Y Y Y
0x36E9
35903
FC273
Y Y Y Y
54059
0x36EA
FC229
Y Y Y Y
54060
0x36EB
Point 17 Deadband
100000000
F10
30000
Y Y Y Y
Y Y Y Y
0x36ED
35903
FC273
54063
0x36EE
FC229
Y Y Y Y
54064
0x36EF
Point 18 Deadband
100000000
F10
30000
Y Y Y Y
0x36F1
35903
FC273
Y Y Y Y
54067
0x36F2
FC229
Y Y Y Y
54068
0x36F3
Point 19 Deadband
100000000
F10
30000
Y Y Y Y
Y Y Y Y
0x36F5
35903
FC273
54071
0x36F6
FC229
Y Y Y Y
54072
0x36F7
Point 20 Deadband
100000000
F10
30000
Y Y Y Y
0x36F9
35903
FC273
Y Y Y Y
54075
0x36FA
FC229
Y Y Y Y
54076
0x36FB
Point 21 Deadband
100000000
F10
30000
Y Y Y Y
Y Y Y Y
0x36FD
35903
FC273
54079
0x36FE
FC229
Y Y Y Y
54080
0x36FF
Point 22 Deadband
100000000
F10
30000
Y Y Y Y
0x3701
35903
FC273
Y Y Y Y
54083
0x3702
FC229
Y Y Y Y
54084
0x3703
Point 23 Deadband
100000000
F10
30000
Y Y Y Y
0x3705
35903
FC273
Y Y Y Y
54087
0x3706
FC229
Y Y Y Y
54088
0x3707
Point 24 Deadband
100000000
F10
30000
Y Y Y Y
0x3709
35903
FC273
Y Y Y Y
54091
0x370A
FC229
Y Y Y Y
54092
0x370B
Point 25 Deadband
100000000
F10
30000
Y Y Y Y
11-114
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
0x370D
35903
FC273
Y Y Y Y
54095
0x370E
FC229
Y Y Y Y
54096
0x370F
Point 26 Deadband
100000000
F10
30000
Y Y Y Y
35903
FC273
Y Y Y Y
0x3711
54099
0x3712
FC229
Y Y Y Y
54100
0x3713
Point 27 Deadband
100000000
F10
30000
Y Y Y Y
0x3715
35903
FC273
Y Y Y Y
54103
0x3716
FC229
Y Y Y Y
54104
0x3717
Point 28 Deadband
100000000
F10
30000
Y Y Y Y
35903
FC273
Y Y Y Y
0x3719
54107
0x371A
FC229
Y Y Y Y
54108
0x371B
Point 29 Deadband
100000000
F10
30000
Y Y Y Y
0x371D
35903
FC273
Y Y Y Y
54111
0x371E
FC229
Y Y Y Y
54112
0x371F
Point 30 Deadband
100000000
F10
30000
Y Y Y Y
35903
FC273
Y Y Y Y
0x3721
54115
0x3722
FC229
Y Y Y Y
54116
0x3723
Point 31 Deadband
100000000
F10
30000
Y Y Y Y
0x3731
143
FC230
Y Y Y Y
54131
0x3732
143
FC230
Y Y Y Y
0x3733
143
FC230
Y Y Y Y
54133
0x3734
143
FC230
Y Y Y Y
0x3735
143
FC230
Y Y Y Y
54135
0x3736
143
FC230
Y Y Y Y
0x3737
143
FC230
Y Y Y Y
54137
0x3738
143
FC230
Y Y Y Y
0x3739
143
FC230
Y Y Y Y
54139
0x373A
143
FC230
Y Y Y Y
0x373B
143
FC230
Y Y Y Y
54141
0x373C
143
FC230
Y Y Y Y
0x373D
143
FC230
Y Y Y Y
54143
0x373E
143
FC230
Y Y Y Y
11-115
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
0x373F
143
FC230
Y Y Y Y
54145
0x3740
143
FC230
Y Y Y Y
0x3741
143
FC230
Y Y Y Y
54147
0x3742
143
FC230
Y Y Y Y
0x3743
143
FC230
Y Y Y Y
54149
0x3744
143
FC230
Y Y Y Y
0x3745
143
FC230
Y Y Y Y
54151
0x3746
143
FC230
Y Y Y Y
0x3747
143
FC230
Y Y Y Y
54153
0x3748
143
FC230
Y Y Y Y
0x3749
143
FC230
Y Y Y Y
54155
0x374A
143
FC230
Y Y Y Y
0x374B
143
FC230
Y Y Y Y
54157
0x374C
143
FC230
Y Y Y Y
0x374D
143
FC230
Y Y Y Y
54159
0x374E
143
FC230
Y Y Y Y
0x374F
143
FC230
Y Y Y Y
54161
0x3750
143
FC230
Y Y Y Y
Y Y Y Y
IEC104 Protocol
54210
0x3781
Channel 1 Port
FC239A
54211
0x3782
Channel 2 Port
FC239A
Y Y Y Y
54212
0x3783
Common Address of
ASDU
65535
F0
Y Y Y Y
54213
0x3784
Client Address 1
0xFFFFFFFF
F70
Y Y Y Y
54215
0x3786
Client Address 2
0xFFFFFFFF
F70
Y Y Y Y
54217
0x3788
65535
F0
2404
Y Y Y Y
54218
0x3789
65535
F0
2404
Y Y Y Y
54219
0x378A
65535
F0
60
Y Y Y Y
54221
0x378C
16777215
F10
1000
Y Y Y Y
54223
0x378E
16777215
F10
2000
Y Y Y Y
54225
0x3790
16777215
F10
3000
Y Y Y Y
54227
0x3792
16777215
F10
4000
Y Y Y Y
54229
0x3794
16777215
F10
5000
Y Y Y Y
11-116
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
F0
Y Y Y Y
F0
Y Y Y Y
IEC103 Protocol
54250
0x37A9
254
54251
0x37AA
1440
min
255
F0
Y Y Y Y
54271
0x37BE
255
F0
Y Y Y Y
54272
0x37BF
Point 0
0xFFFFFFFF
FC142
Y Y Y Y
F0
Y Y Y Y
0x37CB
255
54285
0x37CC
255
F0
Y Y Y Y
54286
0x37CD Point 1
0xFFFFFFFF
FC142
Y Y Y Y
0x37D9
255
F0
Y Y Y Y
54299
255
F0
Y Y Y Y
54300
0x37DB Point 2
0xFFFFFFFF
FC142
Y Y Y Y
255
F0
Y Y Y Y
0x37E7
54313
0x37E8
255
F0
Y Y Y Y
54314
0x37E9
Point 3
0xFFFFFFFF
FC142
Y Y Y Y
0x37F5
255
F0
Y Y Y Y
54327
0x37F6
255
F0
Y Y Y Y
54328
0x37F7
Point 4
0xFFFFFFFF
FC142
Y Y Y Y
255
F0
Y Y Y Y
0x3803
54341
0x3804
255
F0
Y Y Y Y
54342
0x3805
Point 5
0xFFFFFFFF
FC142
Y Y Y Y
0x3811
255
F0
Y Y Y Y
54355
0x3812
255
F0
Y Y Y Y
54356
0x3813
Point 6
0xFFFFFFFF
FC142
Y Y Y Y
255
F0
Y Y Y Y
0x381F
54369
0x3820
255
F0
Y Y Y Y
54370
0x3821
Point 7
0xFFFFFFFF
FC142
Y Y Y Y
0x382D
255
F0
Y Y Y Y
54383
0x382E
255
F0
Y Y Y Y
54384
0x382F
Point 8
0xFFFFFFFF
FC142
Y Y Y Y
255
F0
Y Y Y Y
0x383B
54397
0x383C
255
F0
Y Y Y Y
54398
0x383D
Point 9
0xFFFFFFFF
FC142
Y Y Y Y
255
F0
Y Y Y Y
0x3849
11-117
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
54411
0x384A
255
F0
Y Y Y Y
54412
0x384B
Point 10
0xFFFFFFFF
FC142
Y Y Y Y
255
F0
Y Y Y Y
0x3857
54425
0x3858
255
F0
Y Y Y Y
54426
0x3859
Point 11
0xFFFFFFFF
FC142
Y Y Y Y
0x3865
255
F0
Y Y Y Y
54439
0x3866
255
F0
Y Y Y Y
54440
0x3867
Point 12
0xFFFFFFFF
FC142
Y Y Y Y
255
F0
Y Y Y Y
0x3873
54453
0x3874
255
F0
Y Y Y Y
54454
0x3875
Point 13
0xFFFFFFFF
FC142
Y Y Y Y
0x3881
255
F0
Y Y Y Y
54467
0x3882
255
F0
Y Y Y Y
54468
0x3883
Point 14
0xFFFFFFFF
FC142
Y Y Y Y
255
F0
Y Y Y Y
0x388F
54481
0x3890
255
F0
Y Y Y Y
54482
0x3891
Point 15
0xFFFFFFFF
FC142
Y Y Y Y
0x389D
255
F0
Y Y Y Y
54495
0x389E
255
F0
Y Y Y Y
54496
0x389F
Point 16
0xFFFFFFFF
FC142
Y Y Y Y
255
F0
Y Y Y Y
0x38AB
54509
0x38AC
54510
0x38AD Point 17
255
F0
Y Y Y Y
0xFFFFFFFF
FC142
Y Y Y Y
0x38B9
255
F0
Y Y Y Y
54523
0x38BA
255
F0
Y Y Y Y
54524
0x38BB
Point 18
0xFFFFFFFF
FC142
Y Y Y Y
255
F0
Y Y Y Y
0x38C7
54537
0x38C8
255
F0
Y Y Y Y
54538
0x38C9
Point 19
0xFFFFFFFF
FC142
Y Y Y Y
0x38D5
255
F0
Y Y Y Y
54551
0x38D6
255
F0
Y Y Y Y
54552
0x38D7
Point 20
0xFFFFFFFF
FC142
Y Y Y Y
0x38E3
255
F0
Y Y Y Y
54565
0x38E4
255
F0
Y Y Y Y
11-118
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
54566
0xFFFFFFFF
FC142
Y Y Y Y
0x38E5
Point 21
0x38F1
255
F0
Y Y Y Y
54579
0x38F2
255
F0
Y Y Y Y
54580
0x38F3
Point 22
0xFFFFFFFF
FC142
Y Y Y Y
Y Y Y Y
0x38FF
255
F0
54593
0x3900
255
F0
Y Y Y Y
54594
0x3901
Point 23
0xFFFFFFFF
FC142
Y Y Y Y
0x390D
255
F0
Y Y Y Y
54607
0x390E
255
F0
Y Y Y Y
54608
0x390F
Point 24
0xFFFFFFFF
FC142
Y Y Y Y
Y Y Y Y
0x391B
255
F0
54621
0x391C
255
F0
Y Y Y Y
54622
0x391D
Point 25
0xFFFFFFFF
FC142
Y Y Y Y
0x3929
255
F0
Y Y Y Y
54635
0x392A
255
F0
Y Y Y Y
54636
0x392B
Point 26
0xFFFFFFFF
FC142
Y Y Y Y
Y Y Y Y
0x3937
255
F0
54649
0x3938
255
F0
Y Y Y Y
54650
0x3939
Point 27
0xFFFFFFFF
FC142
Y Y Y Y
0x3945
255
F0
Y Y Y Y
54663
0x3946
255
F0
Y Y Y Y
54664
0x3947
Point 28
0xFFFFFFFF
FC142
Y Y Y Y
Y Y Y Y
0x3953
255
F0
54677
0x3954
255
F0
Y Y Y Y
54678
0x3955
Point 29
0xFFFFFFFF
FC142
Y Y Y Y
0x3961
255
F0
Y Y Y Y
54691
0x3962
255
F0
Y Y Y Y
54692
0x3963
Point 30
0xFFFFFFFF
FC142
Y Y Y Y
Y Y Y Y
0x396F
255
F0
54705
0x3970
255
F0
Y Y Y Y
54706
0x3971
Point 31
0xFFFFFFFF
FC142
Y Y Y Y
0x397D
255
F0
Y Y Y Y
54719
0x397E
255
F0
Y Y Y Y
54720
0x397F
Point 32
0xFFFFFFFF
FC142
Y Y Y Y
11-119
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
0x398B
255
F0
54733
0x398C
255
F0
Y Y Y Y
Y Y Y Y
54734
0x398D
Point 33
0xFFFFFFFF
FC142
Y Y Y Y
255
F0
Y Y Y Y
0x3999
54747
0x399A
255
F0
Y Y Y Y
54748
0x399B
Point 34
0xFFFFFFFF
FC142
Y Y Y Y
Y Y Y Y
0x39A7
255
F0
54761
0x39A8
255
F0
Y Y Y Y
54762
0x39A9
Point 35
0xFFFFFFFF
FC142
Y Y Y Y
255
F0
Y Y Y Y
0x39B5
54775
0x39B6
255
F0
Y Y Y Y
54776
0x39B7
Point 36
0xFFFFFFFF
FC142
Y Y Y Y
0x39C3
255
F0
Y Y Y Y
54789
0x39C4
255
F0
Y Y Y Y
54790
0x39C5
Point 37
0xFFFFFFFF
FC142
Y Y Y Y
255
F0
Y Y Y Y
0x39D1
54803
0x39D2
255
F0
Y Y Y Y
54804
0x39D3
Point 38
0xFFFFFFFF
FC142
Y Y Y Y
Y Y Y Y
0x39DF
255
F0
54817
0x39E0
255
F0
Y Y Y Y
54818
0x39E1
Point 39
0xFFFFFFFF
FC142
Y Y Y Y
255
F0
Y Y Y Y
0x39ED
54831
0x39EE
255
F0
Y Y Y Y
54832
0x39EF
Point 40
0xFFFFFFFF
FC142
Y Y Y Y
Y Y Y Y
0x39FB
255
F0
54845
0x39FC
255
F0
Y Y Y Y
54846
0x39FD
Point 41
0xFFFFFFFF
FC142
Y Y Y Y
255
F0
Y Y Y Y
0x3A09
54859
0x3A0A
255
F0
Y Y Y Y
54860
0x3A0B
Point 42
0xFFFFFFFF
FC142
Y Y Y Y
Y Y Y Y
0x3A17
255
F0
54873
0x3A18
255
F0
Y Y Y Y
54874
0x3A19
Point 43
0xFFFFFFFF
FC142
Y Y Y Y
11-120
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
54886
255
F0
0x3A25
Y Y Y Y
54887
0x3A26
255
F0
Y Y Y Y
54888
0x3A27
Point 44
0xFFFFFFFF
FC142
Y Y Y Y
0x3A33
255
F0
Y Y Y Y
54901
0x3A34
255
F0
Y Y Y Y
54902
0x3A35
Point 45
0xFFFFFFFF
FC142
Y Y Y Y
255
F0
Y Y Y Y
0x3A41
54915
0x3A42
255
F0
Y Y Y Y
54916
0x3A43
Point 46
0xFFFFFFFF
FC142
Y Y Y Y
0x3A4F
255
F0
Y Y Y Y
54929
0x3A50
255
F0
Y Y Y Y
54930
0x3A51
Point 47
0xFFFFFFFF
FC142
Y Y Y Y
255
F0
Y Y Y Y
54943
0x3A5E
255
F0
Y Y Y Y
54944
0x3A5F
Point 48
0xFFFFFFFF
FC142
Y Y Y Y
0x3A6B
255
F0
Y Y Y Y
54957
0x3A6C
255
F0
Y Y Y Y
54958
0x3A6D Point 49
0xFFFFFFFF
FC142
Y Y Y Y
255
F0
Y Y Y Y
0x3A79
54971
0x3A7A
255
F0
Y Y Y Y
54972
0x3A7B
Point 50
0xFFFFFFFF
FC142
Y Y Y Y
0x3A87
255
F0
Y Y Y Y
54985
0x3A88
255
F0
Y Y Y Y
54986
0x3A89
Point 51
0xFFFFFFFF
FC142
Y Y Y Y
255
F0
Y Y Y Y
0x3A95
54999
0x3A96
255
F0
Y Y Y Y
55000
0x3A97
Point 52
0xFFFFFFFF
FC142
Y Y Y Y
0x3AA3
255
F0
Y Y Y Y
55013
0x3AA4
255
F0
Y Y Y Y
55014
0x3AA5
Point 53
0xFFFFFFFF
FC142
Y Y Y Y
255
F0
Y Y Y Y
0x3AB1
55027
0x3AB2
255
F0
Y Y Y Y
55028
0x3AB3
Point 54
0xFFFFFFFF
FC142
Y Y Y Y
255
F0
Y Y Y Y
0x3ABF
11-121
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
55041
0x3AC0
255
F0
Y Y Y Y
55042
0x3AC1
Point 55
0xFFFFFFFF
FC142
Y Y Y Y
255
F0
Y Y Y Y
55055
0x3ACE
255
F0
Y Y Y Y
55056
0x3ACF
Point 56
0xFFFFFFFF
FC142
Y Y Y Y
255
F0
Y Y Y Y
55069
255
F0
Y Y Y Y
55070
0x3ADD Point 57
0xFFFFFFFF
FC142
Y Y Y Y
255
F0
Y Y Y Y
0x3AE9
55083
0x3AEA
255
F0
Y Y Y Y
55084
0x3AEB
Point 58
0xFFFFFFFF
FC142
Y Y Y Y
0x3AF7
255
F0
Y Y Y Y
55097
0x3AF8
255
F0
Y Y Y Y
55098
0x3AF9
Point 59
0xFFFFFFFF
FC142
Y Y Y Y
255
F0
Y Y Y Y
0x3B05
55111
0x3B06
255
F0
Y Y Y Y
55112
0x3B07
Point 60
0xFFFFFFFF
FC142
Y Y Y Y
0x3B13
255
F0
Y Y Y Y
55125
0x3B14
255
F0
Y Y Y Y
55126
0x3B15
Point 61
0xFFFFFFFF
FC142
Y Y Y Y
255
F0
Y Y Y Y
0x3B21
55139
0x3B22
255
F0
Y Y Y Y
55140
0x3B23
Point 62
0xFFFFFFFF
FC142
Y Y Y Y
0x3B2F
255
F0
Y Y Y Y
55153
0x3B30
255
F0
Y Y Y Y
55154
0x3B31
Point 63
0xFFFFFFFF
FC142
Y Y Y Y
255
F0
Y Y Y Y
55167
0x3B3E
255
F0
Y Y Y Y
55168
0x3B3F
Point 64
0xFFFFFFFF
FC142
Y Y Y Y
0x3B4B
255
F0
Y Y Y Y
55181
0x3B4C
255
F0
Y Y Y Y
55182
0x3B4D Point 65
0xFFFFFFFF
FC142
Y Y Y Y
0x3B59
255
F0
Y Y Y Y
55195
0x3B5A
255
F0
Y Y Y Y
11-122
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
55196
0xFFFFFFFF
FC142
Y Y Y Y
0x3B5B
Point 66
0x3B67
255
F0
Y Y Y Y
55209
0x3B68
255
F0
Y Y Y Y
55210
0x3B69
Point 67
0xFFFFFFFF
FC142
Y Y Y Y
Y Y Y Y
0x3B75
255
F0
55223
0x3B76
255
F0
Y Y Y Y
55224
0x3B77
Point 68
0xFFFFFFFF
FC142
Y Y Y Y
0x3B83
255
F0
Y Y Y Y
55237
0x3B84
255
F0
Y Y Y Y
55238
0x3B85
Point 69
0xFFFFFFFF
FC142
Y Y Y Y
Y Y Y Y
0x3B91
255
F0
55251
0x3B92
255
F0
Y Y Y Y
55252
0x3B93
Point 70
0xFFFFFFFF
FC142
Y Y Y Y
0x3B9F
255
F0
Y Y Y Y
55265
0x3BA0
255
F0
Y Y Y Y
55266
0x3BA1
Point 71
0xFFFFFFFF
FC142
Y Y Y Y
255
F0
Y Y Y Y
55279
0x3BAE
255
F0
Y Y Y Y
55280
0x3BAF
Point 72
0xFFFFFFFF
FC142
Y Y Y Y
0x3BBB
255
F0
Y Y Y Y
55293
255
F0
Y Y Y Y
55294
0x3BBD Point 73
0xFFFFFFFF
FC142
Y Y Y Y
Y Y Y Y
0x3BC9
255
F0
55307
255
F0
Y Y Y Y
55308
0x3BCB Point 74
0xFFFFFFFF
FC142
Y Y Y Y
255
F0
Y Y Y Y
55321
255
F0
Y Y Y Y
55322
0x3BD9 Point 75
0xFFFFFFFF
FC142
Y Y Y Y
Y Y Y Y
0x3BE5
255
F0
55335
0x3BE6
255
F0
Y Y Y Y
55336
0x3BE7
Point 76
0xFFFFFFFF
FC142
Y Y Y Y
0x3BF3
255
F0
Y Y Y Y
55349
0x3BF4
255
F0
Y Y Y Y
55350
0x3BF5
Point 77
0xFFFFFFFF
FC142
Y Y Y Y
11-123
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
0x3C01
255
F0
Y Y Y Y
55363
0x3C02
255
F0
Y Y Y Y
55364
0x3C03
Point 78
0xFFFFFFFF
FC142
Y Y Y Y
255
F0
Y Y Y Y
0x3C0F
55377
0x3C10
255
F0
Y Y Y Y
55378
0x3C11
Point 79
0xFFFFFFFF
FC142
Y Y Y Y
255
F0
Y Y Y Y
55391
0x3C1E
255
F0
Y Y Y Y
55392
0x3C1F
Point 80
0xFFFFFFFF
FC142
Y Y Y Y
255
F0
Y Y Y Y
0x3C2B
55405
0x3C2C
55406
0x3C2D Point 81
255
F0
Y Y Y Y
0xFFFFFFFF
FC142
Y Y Y Y
0x3C39
255
F0
Y Y Y Y
55419
0x3C3A
255
F0
Y Y Y Y
55420
0x3C3B
Point 82
0xFFFFFFFF
FC142
Y Y Y Y
255
F0
Y Y Y Y
0x3C47
55433
0x3C48
255
F0
Y Y Y Y
55434
0x3C49
Point 83
0xFFFFFFFF
FC142
Y Y Y Y
0x3C55
255
F0
Y Y Y Y
55447
0x3C56
255
F0
Y Y Y Y
55448
0x3C57
Point 84
0xFFFFFFFF
FC142
Y Y Y Y
255
F0
Y Y Y Y
0x3C63
55461
0x3C64
255
F0
Y Y Y Y
55462
0x3C65
Point 85
0xFFFFFFFF
FC142
Y Y Y Y
0x3C71
255
F0
Y Y Y Y
55475
0x3C72
255
F0
Y Y Y Y
55476
0x3C73
Point 86
0xFFFFFFFF
FC142
Y Y Y Y
255
F0
Y Y Y Y
0x3C7F
55489
0x3C80
255
F0
Y Y Y Y
55490
0x3C81
Point 87
0xFFFFFFFF
FC142
Y Y Y Y
255
F0
Y Y Y Y
55503
0x3C8E
255
F0
Y Y Y Y
55504
0x3C8F
Point 88
0xFFFFFFFF
FC142
Y Y Y Y
11-124
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
55516
255
F0
0x3C9B
55517
0x3C9C
55518
0x3C9D Point 89
Y Y Y Y
255
F0
Y Y Y Y
0xFFFFFFFF
FC142
Y Y Y Y
0x3CA9
255
F0
Y Y Y Y
55531
255
F0
Y Y Y Y
55532
0x3CAB Point 90
0xFFFFFFFF
FC142
Y Y Y Y
255
F0
Y Y Y Y
0x3CB7
55545
0x3CB8
255
F0
Y Y Y Y
55546
0x3CB9
Point 91
0xFFFFFFFF
FC142
Y Y Y Y
0x3CC5
255
F0
Y Y Y Y
55559
0x3CC6
255
F0
Y Y Y Y
55560
0x3CC7
Point 92
0xFFFFFFFF
FC142
Y Y Y Y
255
F0
Y Y Y Y
55573
255
F0
Y Y Y Y
55574
0x3CD5 Point 93
0xFFFFFFFF
FC142
Y Y Y Y
0x3CE1
255
F0
Y Y Y Y
55587
0x3CE2
255
F0
Y Y Y Y
55588
0x3CE3
Point 94
0xFFFFFFFF
FC142
Y Y Y Y
255
F0
Y Y Y Y
0x3CEF
55601
0x3CF0
255
F0
Y Y Y Y
55602
0x3CF1
Point 95
0xFFFFFFFF
FC142
Y Y Y Y
First ADSU
55630
FC212
Y Y Y Y
55631
0x3D0E
255
F0
Y Y Y Y
55632
0x3D0F
255
F0
Y Y Y Y
55633
0x3D10
1000
F0
Y Y Y Y
55634
0x3D11
35903
FC273
Y Y Y Y
55635
0x3D12
65535
F3
Y Y Y Y
55636
0x3D13
-32768
32767
F20
Y Y Y Y
55637
0x3D14
35903
FC273
Y Y Y Y
55638
0x3D15
65535
F3
Y Y Y Y
55639
0x3D16
-32768
32767
F20
Y Y Y Y
55640
0x3D17
35903
FC273
Y Y Y Y
55641
0x3D18
65535
F3
Y Y Y Y
55642
0x3D19
-32768
32767
F20
Y Y Y Y
55643
35903
FC273
Y Y Y Y
55644
65535
F3
Y Y Y Y
55645
-32768
32767
F20
Y Y Y Y
55646
35903
FC273
Y Y Y Y
11-125
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
55647
65535
F3
0x3D1E
Y Y Y Y
55648
0x3D1F
-32768
32767
F20
Y Y Y Y
55649
0x3D20
35903
FC273
Y Y Y Y
55650
0x3D21
65535
F3
Y Y Y Y
55651
0x3D22
-32768
32767
F20
Y Y Y Y
55652
0x3D23
35903
FC273
Y Y Y Y
55653
0x3D24
65535
F3
Y Y Y Y
55654
0x3D25
-32768
32767
F20
Y Y Y Y
55655
0x3D26
35903
FC273
Y Y Y Y
55656
0x3D27
65535
F3
Y Y Y Y
55657
0x3D28
-32768
32767
F20
Y Y Y Y
55658
0x3D29
35903
FC273
Y Y Y Y
55659
65535
F3
Y Y Y Y
55660
-32768
32767
F20
Y Y Y Y
Second ADSU
55671
0x3D36
FC212
Y Y Y Y
55672
0x3D37
255
F0
Y Y Y Y
55673
0x3D38
255
F0
Y Y Y Y
55674
0x3D39
1000
F0
Y Y Y Y
55675
35903
FC273
Y Y Y Y
55676
65535
F3
Y Y Y Y
55677
-32768
32767
F20
Y Y Y Y
55678
35903
FC273
Y Y Y Y
55679
0x3D3E
65535
F3
Y Y Y Y
55680
0x3D3F
-32768
32767
F20
Y Y Y Y
55681
0x3D40
35903
FC273
Y Y Y Y
55682
0x3D41
65535
F3
Y Y Y Y
55683
0x3D42
-32768
32767
F20
Y Y Y Y
55684
0x3D43
35903
FC273
Y Y Y Y
55685
0x3D44
65535
F3
Y Y Y Y
55686
0x3D45
-32768
32767
F20
Y Y Y Y
55687
0x3D46
35903
FC273
Y Y Y Y
55688
0x3D47
65535
F3
Y Y Y Y
55689
0x3D48
-32768
32767
F20
Y Y Y Y
55690
0x3D49
35903
FC273
Y Y Y Y
55691
65535
F3
Y Y Y Y
55692
-32768
32767
F20
Y Y Y Y
55693
35903
FC273
Y Y Y Y
55694
65535
F3
Y Y Y Y
55695
0x3D4E
-32768
32767
F20
Y Y Y Y
55696
0x3D4F
35903
FC273
Y Y Y Y
55697
0x3D50
65535
F3
Y Y Y Y
55698
0x3D51
-32768
32767
F20
Y Y Y Y
55699
0x3D52
35903
FC273
Y Y Y Y
55700
0x3D53
65535
F3
Y Y Y Y
11-126
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
55701
-32768
32767
F20
Y Y Y Y
0x3D54
Third ADSU
55712
0x3D5F
FC212
Y Y Y Y
55713
0x3D60
255
F0
Y Y Y Y
55714
0x3D61
255
F0
Y Y Y Y
55715
0x3D62
1000
F0
Y Y Y Y
55716
0x3D63
35903
FC273
Y Y Y Y
55717
0x3D64
65535
F3
Y Y Y Y
55718
0x3D65
-32768
32767
F20
Y Y Y Y
55719
0x3D66
35903
FC273
Y Y Y Y
55720
0x3D67
65535
F3
Y Y Y Y
55721
0x3D68
-32768
32767
F20
Y Y Y Y
55722
0x3D69
35903
FC273
Y Y Y Y
55723
65535
F3
Y Y Y Y
55724
-32768
32767
F20
Y Y Y Y
55725
35903
FC273
Y Y Y Y
55726
65535
F3
Y Y Y Y
55727
0x3D6E
-32768
32767
F20
Y Y Y Y
55728
0x3D6F
35903
FC273
Y Y Y Y
55729
0x3D70
65535
F3
Y Y Y Y
55730
0x3D71
-32768
32767
F20
Y Y Y Y
55731
0x3D72
35903
FC273
Y Y Y Y
55732
0x3D73
65535
F3
Y Y Y Y
55733
0x3D74
-32768
32767
F20
Y Y Y Y
55734
0x3D75
35903
FC273
Y Y Y Y
55735
0x3D76
65535
F3
Y Y Y Y
55736
0x3D77
-32768
32767
F20
Y Y Y Y
55737
0x3D78
35903
FC273
Y Y Y Y
55738
0x3D79
65535
F3
Y Y Y Y
55739
-32768
32767
F20
Y Y Y Y
55740
35903
FC273
Y Y Y Y
55741
65535
F3
Y Y Y Y
55742
-32768
32767
F20
Y Y Y Y
Fourth ADSU
55753
0x3D88
FC212
Y Y Y Y
55754
0x3D89
255
F0
Y Y Y Y
55755
255
F0
Y Y Y Y
55756
1000
F0
Y Y Y Y
55757
35903
FC273
Y Y Y Y
55758
65535
F3
Y Y Y Y
55759
0x3D8E
-32768
32767
F20
Y Y Y Y
55760
0x3D8F
35903
FC273
Y Y Y Y
55761
0x3D90
65535
F3
Y Y Y Y
55762
0x3D91
-32768
32767
F20
Y Y Y Y
55763
0x3D92
35903
FC273
Y Y Y Y
11-127
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
55764
0x3D93
65535
F3
55765
0x3D94
-32768
32767
F20
Y Y Y Y
55766
0x3D95
35903
FC273
Y Y Y Y
55767
0x3D96
65535
F3
Y Y Y Y
55768
0x3D97
-32768
32767
F20
Y Y Y Y
55769
0x3D98
35903
FC273
Y Y Y Y
55770
0x3D99
65535
F3
Y Y Y Y
55771
-32768
32767
F20
Y Y Y Y
55772
35903
FC273
Y Y Y Y
55773
65535
F3
Y Y Y Y
55774
-32768
32767
F20
Y Y Y Y
55775
0x3D9E
35903
FC273
Y Y Y Y
55776
0x3D9F
65535
F3
Y Y Y Y
55777
-32768
32767
F20
Y Y Y Y
55778
35903
FC273
Y Y Y Y
55779
65535
F3
Y Y Y Y
55780
-32768
32767
F20
Y Y Y Y
55781
35903
FC273
Y Y Y Y
55782
65535
F3
Y Y Y Y
55783
-32768
32767
F20
Y Y Y Y
Y Y Y Y
IEC103 Command 0
55810
255
F0
Y Y Y Y
55811
255
F0
Y Y Y Y
55812
0x3DC3 Command 0 ON
143
FC230
Y Y Y Y
55813
143
FC230
Y Y Y Y
IEC103 Command 1
55814
255
F0
Y Y Y Y
55815
255
F0
Y Y Y Y
55816
0x3DC7 Command 1 ON
143
FC230
Y Y Y Y
55817
143
FC230
Y Y Y Y
IEC103 Command 2
55818
255
F0
Y Y Y Y
55819
255
F0
Y Y Y Y
55820
0x3DCB Command 2 ON
143
FC230
Y Y Y Y
55821
143
FC230
Y Y Y Y
IEC103 Command 3
55822
255
F0
Y Y Y Y
55823
255
F0
Y Y Y Y
55824
0x3DCF Command 3 ON
143
FC230
Y Y Y Y
55825
143
FC230
Y Y Y Y
Y Y Y Y
IEC103 Command 4
55826
255
F0
55827
255
F0
Y Y Y Y
55828
0x3DD3 Command 4 ON
143
FC230
Y Y Y Y
55829
143
FC230
Y Y Y Y
11-128
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
IEC103 Command 5
55830
255
F0
Y Y Y Y
55831
255
F0
Y Y Y Y
55832
0x3DD7 Command 5 ON
143
FC230
Y Y Y Y
55833
143
FC230
Y Y Y Y
Y Y Y Y
IEC103 Command 6
55834
255
F0
55835
255
F0
Y Y Y Y
55836
0x3DDB Command 6 ON
143
FC230
Y Y Y Y
55837
143
FC230
Y Y Y Y
255
F0
Y Y Y Y
IEC103 Command 7
55838
55839
255
F0
Y Y Y Y
55840
0x3DDF Command 7 ON
143
FC230
Y Y Y Y
55841
0x3DE0
Command 7 OFF
143
FC230
Y Y Y Y
255
F0
Y Y Y Y
IEC103 Command 8
55842
0x3DE1
55843
0x3DE2
255
F0
Y Y Y Y
55844
0x3DE3
Command 8 ON
143
FC230
Y Y Y Y
55845
0x3DE4
Command 8 OFF
143
FC230
Y Y Y Y
255
F0
Y Y Y Y
IEC103 Command 9
55846
0x3DE5
55847
0x3DE6
255
F0
Y Y Y Y
55848
0x3DE7
Command 9 ON
143
FC230
Y Y Y Y
55849
0x3DE8
Command 9 OFF
143
FC230
Y Y Y Y
255
F0
Y Y Y Y
255
F0
Y Y Y Y
IEC103 Command 10
55850
0x3DE9
55851
55852
0x3DEB Command 10 ON
143
FC230
Y Y Y Y
55853
143
FC230
Y Y Y Y
IEC103 Command 11
55854
255
F0
Y Y Y Y
55855
0x3DEE
255
F0
Y Y Y Y
55856
0x3DEF
Command 11 ON
143
FC230
Y Y Y Y
55857
0x3DF0
Command 11 OFF
143
FC230
Y Y Y Y
IEC103 Command 12
55858
0x3DF1
255
F0
Y Y Y Y
55859
0x3DF2
255
F0
Y Y Y Y
55860
0x3DF3
Command 12 ON
143
FC230
Y Y Y Y
55861
0x3DF4
Command 12 OFF
143
FC230
Y Y Y Y
IEC103 Command 13
55862
0x3DF5
255
F0
Y Y Y Y
55863
0x3DF6
255
F0
Y Y Y Y
55864
0x3DF7
Command 13 ON
143
FC230
Y Y Y Y
55865
0x3DF8
Command 13 OFF
143
FC230
Y Y Y Y
11-129
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
IEC103 Command 14
55866
0x3DF9
255
F0
Y Y Y Y
55867
0x3DFA
255
F0
Y Y Y Y
55868
0x3DFB
Command 14 ON
143
FC230
Y Y Y Y
55869
0x3DFC
Command 14 OFF
143
FC230
Y Y Y Y
IEC103 Command 15
55870
255
F0
Y Y Y Y
55871
0x3DFE
255
F0
Y Y Y Y
55872
0x3DFF
Command 15 ON
143
FC230
Y Y Y Y
55873
0x3E00
Command 15 OFF
143
FC230
Y Y Y Y
IEC103 Command 16
55874
0x3E01
255
F0
Y Y Y Y
55875
0x3E02
255
F0
Y Y Y Y
55876
0x3E03
Command 16 ON
143
FC230
Y Y Y Y
55877
0x3E04
Command 16 OFF
143
FC230
Y Y Y Y
IEC103 Command 17
55878
0x3E05
255
F0
Y Y Y Y
55879
0x3E06
255
F0
Y Y Y Y
55880
0x3E07
Command 17 ON
143
FC230
Y Y Y Y
55881
0x3E08
Command 17 OFF
143
FC230
Y Y Y Y
IEC103 Command 18
55882
0x3E09
255
F0
Y Y Y Y
55883
0x3E0A
255
F0
Y Y Y Y
55884
0x3E0B
Command 18 ON
143
FC230
Y Y Y Y
55885
0x3E0C
Command 18 OFF
143
FC230
Y Y Y Y
IEC103 Command 19
55886
0x3E0D
255
F0
Y Y Y Y
55887
0x3E0E
255
F0
Y Y Y Y
55888
0x3E0F
Command 19 ON
143
FC230
Y Y Y Y
55889
0x3E10
Command 19 OFF
143
FC230
Y Y Y Y
IEC103 Command 20
55890
0x3E11
255
F0
Y Y Y Y
55891
0x3E12
255
F0
Y Y Y Y
55892
0x3E13
Command 20 ON
143
FC230
Y Y Y Y
55893
0x3E14
Command 20 OFF
143
FC230
Y Y Y Y
IEC103 Command 21
55894
0x3E15
255
F0
Y Y Y Y
55895
0x3E16
255
F0
Y Y Y Y
55896
0x3E17
Command 21 ON
143
FC230
Y Y Y Y
55897
0x3E18
Command 21 OFF
143
FC230
Y Y Y Y
IEC103 Command 22
55898
0x3E19
255
F0
Y Y Y Y
55899
0x3E1A
255
F0
Y Y Y Y
55900
0x3E1B
Command 22 ON
143
FC230
Y Y Y Y
55901
0x3E1C
Command 22 OFF
143
FC230
Y Y Y Y
11-130
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
IEC103 Command 23
55902
0x3E1D
255
F0
Y Y Y Y
55903
0x3E1E
255
F0
Y Y Y Y
55904
0x3E1F
Command 23 ON
143
FC230
Y Y Y Y
55905
0x3E20
Command 23 OFF
143
FC230
Y Y Y Y
IEC103 Command 24
55906
0x3E21
255
F0
Y Y Y Y
55907
0x3E22
255
F0
Y Y Y Y
55908
0x3E23
Command 24 ON
143
FC230
Y Y Y Y
55909
0x3E24
Command 24 OFF
143
FC230
Y Y Y Y
IEC103 Command 25
55910
0x3E25
255
F0
Y Y Y Y
55911
0x3E26
255
F0
Y Y Y Y
55912
0x3E27
Command 25 ON
143
FC230
Y Y Y Y
55913
0x3E28
Command 25 OFF
143
FC230
Y Y Y Y
IEC103 Command 26
55914
0x3E29
255
F0
Y Y Y Y
55915
0x3E2A
255
F0
Y Y Y Y
55916
0x3E2B
Command 26 ON
143
FC230
Y Y Y Y
55917
0x3E2C
Command 26 OFF
143
FC230
Y Y Y Y
IEC103 Command 27
55918
0x3E2D
255
F0
Y Y Y Y
55919
0x3E2E
255
F0
Y Y Y Y
55920
0x3E2F
Command 27 ON
143
FC230
Y Y Y Y
55921
0x3E30
Command 27 OFF
143
FC230
Y Y Y Y
IEC103 Command 28
55922
0x3E31
255
F0
Y Y Y Y
55923
0x3E32
255
F0
Y Y Y Y
55924
0x3E33
Command 28 ON
143
FC230
Y Y Y Y
55925
0x3E34
Command 28 OFF
143
FC230
Y Y Y Y
IEC103 Command 29
55926
0x3E35
255
F0
Y Y Y Y
55927
0x3E36
255
F0
Y Y Y Y
55928
0x3E37
Command 29 ON
143
FC230
Y Y Y Y
55929
0x3E38
Command 29 OFF
143
FC230
Y Y Y Y
IEC103 Command 30
55930
0x3E39
255
F0
Y Y Y Y
55931
0x3E3A
255
F0
Y Y Y Y
55932
0x3E3B
Command 30 ON
143
FC230
Y Y Y Y
55933
0x3E3C
Command 30 OFF
143
FC230
Y Y Y Y
IEC103 Command 31
55934
0x3E3D
255
F0
Y Y Y Y
55935
0x3E3E
255
F0
Y Y Y Y
55936
0x3E3F
Command 31 ON
143
FC230
Y Y Y Y
55937
0x3E40
Command 31 OFF
143
FC230
Y Y Y Y
11-131
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
GGIO1 Indications
55950
0x3E4D
GGIO1 Indication 1
0xFFFFFFFF
FC142
Y Y Y Y
55952
0x3E4F
GGIO1 Indication 2
0xFFFFFFFF
FC142
Y Y Y Y
55954
0x3E51
GGIO1 Indication 3
0xFFFFFFFF
FC142
Y Y Y Y
55956
0x3E53
GGIO1 Indication 4
0xFFFFFFFF
FC142
Y Y Y Y
55958
0x3E55
GGIO1 Indication 5
0xFFFFFFFF
FC142
Y Y Y Y
55960
0x3E57
GGIO1 Indication 6
0xFFFFFFFF
FC142
Y Y Y Y
55962
0x3E59
GGIO1 Indication 7
0xFFFFFFFF
FC142
Y Y Y Y
55964
0x3E5B
GGIO1 Indication 8
0xFFFFFFFF
FC142
Y Y Y Y
55966
0x3E5D
GGIO1 Indication 9
0xFFFFFFFF
FC142
Y Y Y Y
55968
0x3E5F
GGIO1 Indication 10
0xFFFFFFFF
FC142
Y Y Y Y
55970
0x3E61
GGIO1 Indication 11
0xFFFFFFFF
FC142
Y Y Y Y
55972
0x3E63
GGIO1 Indication 12
0xFFFFFFFF
FC142
Y Y Y Y
55974
0x3E65
GGIO1 Indication 13
0xFFFFFFFF
FC142
Y Y Y Y
55976
0x3E67
GGIO1 Indication 14
0xFFFFFFFF
FC142
Y Y Y Y
55978
0x3E69
GGIO1 Indication 15
0xFFFFFFFF
FC142
Y Y Y Y
55980
0x3E6B
GGIO1 Indication 16
0xFFFFFFFF
FC142
Y Y Y Y
55982
0x3E6D
GGIO1 Indication 17
0xFFFFFFFF
FC142
Y Y Y Y
55984
0x3E6F
GGIO1 Indication 18
0xFFFFFFFF
FC142
Y Y Y Y
55986
0x3E71
GGIO1 Indication 19
0xFFFFFFFF
FC142
Y Y Y Y
55988
0x3E73
GGIO1 Indication 20
0xFFFFFFFF
FC142
Y Y Y Y
55990
0x3E75
GGIO1 Indication 21
0xFFFFFFFF
FC142
Y Y Y Y
55992
0x3E77
GGIO1 Indication 22
0xFFFFFFFF
FC142
Y Y Y Y
55994
0x3E79
GGIO1 Indication 23
0xFFFFFFFF
FC142
Y Y Y Y
55996
0x3E7B
GGIO1 Indication 24
0xFFFFFFFF
FC142
Y Y Y Y
55998
0x3E7D
GGIO1 Indication 25
0xFFFFFFFF
FC142
Y Y Y Y
56000
0x3E7F
GGIO1 Indication 26
0xFFFFFFFF
FC142
Y Y Y Y
56002
0x3E81
GGIO1 Indication 27
0xFFFFFFFF
FC142
Y Y Y Y
56004
0x3E83
GGIO1 Indication 28
0xFFFFFFFF
FC142
Y Y Y Y
56006
0x3E85
GGIO1 Indication 29
0xFFFFFFFF
FC142
Y Y Y Y
56008
0x3E87
GGIO1 Indication 30
0xFFFFFFFF
FC142
Y Y Y Y
56010
0x3E89
GGIO1 Indication 31
0xFFFFFFFF
FC142
Y Y Y Y
56012
0x3E8B
GGIO1 Indication 32
0xFFFFFFFF
FC142
Y Y Y Y
56014
0x3E8D
GGIO1 Indication 33
0xFFFFFFFF
FC142
Y Y Y Y
56016
0x3E8F
GGIO1 Indication 34
0xFFFFFFFF
FC142
Y Y Y Y
56018
0x3E91
GGIO1 Indication 35
0xFFFFFFFF
FC142
Y Y Y Y
56020
0x3E93
GGIO1 Indication 36
0xFFFFFFFF
FC142
Y Y Y Y
56022
0x3E95
GGIO1 Indication 37
0xFFFFFFFF
FC142
Y Y Y Y
56024
0x3E97
GGIO1 Indication 38
0xFFFFFFFF
FC142
Y Y Y Y
56026
0x3E99
GGIO1 Indication 39
0xFFFFFFFF
FC142
Y Y Y Y
56028
0x3E9B
GGIO1 Indication 40
0xFFFFFFFF
FC142
Y Y Y Y
56030
0x3E9D
GGIO1 Indication 41
0xFFFFFFFF
FC142
Y Y Y Y
56032
0x3E9F
GGIO1 Indication 42
0xFFFFFFFF
FC142
Y Y Y Y
56034
0x3EA1
GGIO1 Indication 43
0xFFFFFFFF
FC142
Y Y Y Y
56036
0x3EA3
GGIO1 Indication 44
0xFFFFFFFF
FC142
Y Y Y Y
11-132
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
56038
0x3EA5
GGIO1 Indication 45
0xFFFFFFFF
FC142
Y Y Y Y
56040
0x3EA7
GGIO1 Indication 46
0xFFFFFFFF
FC142
Y Y Y Y
56042
0x3EA9
GGIO1 Indication 47
0xFFFFFFFF
FC142
Y Y Y Y
56044
0x3EAB
GGIO1 Indication 48
0xFFFFFFFF
FC142
Y Y Y Y
56046
0xFFFFFFFF
FC142
Y Y Y Y
56048
0x3EAF
GGIO1 Indication 50
0xFFFFFFFF
FC142
Y Y Y Y
56050
0x3EB1
GGIO1 Indication 51
0xFFFFFFFF
FC142
Y Y Y Y
56052
0x3EB3
GGIO1 Indication 52
0xFFFFFFFF
FC142
Y Y Y Y
56054
0x3EB5
GGIO1 Indication 53
0xFFFFFFFF
FC142
Y Y Y Y
56056
0x3EB7
GGIO1 Indication 54
0xFFFFFFFF
FC142
Y Y Y Y
56058
0x3EB9
GGIO1 Indication 55
0xFFFFFFFF
FC142
Y Y Y Y
56060
0x3EBB
GGIO1 Indication 56
0xFFFFFFFF
FC142
Y Y Y Y
56062
0xFFFFFFFF
FC142
Y Y Y Y
56064
0x3EBF
GGIO1 Indication 58
0xFFFFFFFF
FC142
Y Y Y Y
56066
0x3EC1
GGIO1 Indication 59
0xFFFFFFFF
FC142
Y Y Y Y
56068
0x3EC3
GGIO1 Indication 60
0xFFFFFFFF
FC142
Y Y Y Y
56070
0x3EC5
GGIO1 Indication 61
0xFFFFFFFF
FC142
Y Y Y Y
56072
0x3EC7
GGIO1 Indication 62
0xFFFFFFFF
FC142
Y Y Y Y
56074
0x3EC9
GGIO1 Indication 63
0xFFFFFFFF
FC142
Y Y Y Y
56076
0x3ECB
GGIO1 Indication 64
0xFFFFFFFF
FC142
Y Y Y Y
16
F0
Y Y Y Y
0x3EED
Number of Records
56111
0x3EEE
FC182
Y Y Y Y
56112
0x3EEF
Trigger Mode
FC181
Y Y Y Y
56113
0x3EF0
Trigger Position
100
F0
20
Y Y Y Y
56114
0x3EF1
Trigger Source
0xFFFFFFFF
FC142
Y Y Y Y
56116
0x3EF3
FC126A
Y Y Y Y
56117
0x3EF4
FC126A
Y Y Y Y
56118
0x3EF5
Trigger on Trip
FC126A
Y Y Y Y
56119
0x3EF6
Trigger on Alarm
FC126A
Y Y Y Y
56120
0x3EF7
Digital Input 1
0xFFFFFFFF
FC142
Y Y Y Y
56122
0x3EF9
Digital Input 2
0xFFFFFFFF
FC142
Y Y Y Y
56124
0x3EFB
Digital Input 3
0xFFFFFFFF
FC142
Y Y Y Y
56126
0x3EFD
Digital Input 4
0xFFFFFFFF
FC142
Y Y Y Y
56128
0x3EFF
Digital Input 5
0xFFFFFFFF
FC142
Y Y Y Y
56130
0x3F01
Digital Input 6
0xFFFFFFFF
FC142
Y Y Y Y
56132
0x3F03
Digital Input 7
0xFFFFFFFF
FC142
Y Y Y Y
56134
0x3F05
Digital Input 8
0xFFFFFFFF
FC142
Y Y Y Y
56136
0x3F07
Digital Input 9
0xFFFFFFFF
FC142
Y Y Y Y
56138
0x3F09
Digital Input 10
0xFFFFFFFF
FC142
Y Y Y Y
56140
0x3F0B
Digital Input 11
0xFFFFFFFF
FC142
Y Y Y Y
56142
0x3F0D
Digital Input 12
0xFFFFFFFF
FC142
Y Y Y Y
56144
0x3F0F
Digital Input 13
0xFFFFFFFF
FC142
Y Y Y Y
56146
0x3F11
Digital Input 14
0xFFFFFFFF
FC142
Y Y Y Y
56148
0x3F13
Digital Input 15
0xFFFFFFFF
FC142
Y Y Y Y
11-133
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
56150
0x3F15
Digital Input 16
0xFFFFFFFF
FC142
Y Y Y Y
56152
0x3F17
Digital Input 17
0xFFFFFFFF
FC142
Y Y Y Y
56154
0x3F19
Digital Input 18
0xFFFFFFFF
FC142
Y Y Y Y
56156
0x3F1B
Digital Input 19
0xFFFFFFFF
FC142
Y Y Y Y
56158
0x3F1D
Digital Input 20
0xFFFFFFFF
FC142
Y Y Y Y
56160
0x3F1F
Digital Input 21
0xFFFFFFFF
FC142
Y Y Y Y
56162
0x3F21
Digital Input 22
0xFFFFFFFF
FC142
Y Y Y Y
56164
0x3F23
Digital Input 23
0xFFFFFFFF
FC142
Y Y Y Y
56166
0x3F25
Digital Input 24
0xFFFFFFFF
FC142
Y Y Y Y
56168
0x3F27
Digital Input 25
0xFFFFFFFF
FC142
Y Y Y Y
56170
0x3F29
Digital Input 26
0xFFFFFFFF
FC142
Y Y Y Y
56172
0x3F2B
Digital Input 27
0xFFFFFFFF
FC142
Y Y Y Y
56174
0x3F2D
Digital Input 28
0xFFFFFFFF
FC142
Y Y Y Y
56176
0x3F2F
Digital Input 29
0xFFFFFFFF
FC142
Y Y Y Y
56178
0x3F31
Digital Input 30
0xFFFFFFFF
FC142
Y Y Y Y
56180
0x3F33
Digital Input 31
0xFFFFFFFF
FC142
Y Y Y Y
56182
0x3F35
Digital Input 32
0xFFFFFFFF
FC142
Y Y Y Y
56184
0x3F37
Analog Input 1
35903
FC273
Y Y Y Y
56185
0x3F38
Analog Input 2
35903
FC273
Y Y Y Y
56186
0x3F39
Analog Input 3
35903
FC273
Y Y Y Y
56187
0x3F3A
Analog Input 4
35903
FC273
Y Y Y Y
56188
0x3F3B
Analog Input 5
35903
FC273
Y Y Y Y
56189
0x3F3C
Analog Input 6
35903
FC273
Y Y Y Y
56190
0x3F3D
Analog Input 7
35903
FC273
Y Y Y Y
56191
0x3F3E
Analog Input 8
35903
FC273
Y Y Y Y
56192
0x3F3F
Analog Input 9
35903
FC273
Y Y Y Y
56193
0x3F40
Analog Input 10
35903
FC273
Y Y Y Y
56194
0x3F41
Analog Input 11
35903
FC273
Y Y Y Y
56195
0x3F42
Analog Input 12
35903
FC273
Y Y Y Y
56196
0x3F43
Analog Input 13
35903
FC273
Y Y Y Y
56197
0x3F44
Analog Input 14
35903
FC273
Y Y Y Y
56198
0x3F45
Analog Input 15
35903
FC273
Y Y Y Y
56199
0x3F46
Analog Input 16
35903
FC273
Y Y Y Y
Data Logger
56210
0x3F51
Function
FC186
Y Y Y Y
56211
0x3F52
Trigger
0xFFFFFFFF
FC142
Y Y Y Y
56213
0x3F54
Trigger Position
50
F0
20
Y Y Y Y
56214
0x3F55
Rate
FC183
Y Y Y Y
56215
0x3F56
Channel 1 Source
35903
FC273
Y Y Y Y
56216
0x3F57
Channel 2 Source
35903
FC273
Y Y Y Y
56217
0x3F58
Channel 3 Source
35903
FC273
Y Y Y Y
56218
0x3F59
Channel 4 Source
35903
FC273
Y Y Y Y
56219
0x3F5A
Channel 5 Source
35903
FC273
Y Y Y Y
56220
0x3F5B
Channel 6 Source
35903
FC273
Y Y Y Y
56221
0x3F5C
Channel 7 Source
35903
FC273
Y Y Y Y
11-134
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
56222
0x3F5D
35903
FC273
56223
0x3F5E
Channel 9 Source
35903
FC273
Y Y Y Y
56224
0x3F5F
Channel 10 Source
35903
FC273
Y Y Y Y
56225
0x3F60
Channel 11 Source
35903
FC273
Y Y Y Y
56226
0x3F61
Channel 12 Source
35903
FC273
Y Y Y Y
56227
0x3F62
Channel 13 Source
35903
FC273
Y Y Y Y
56228
0x3F63
Channel 14 Source
35903
FC273
Y Y Y Y
56229
0x3F64
Channel 15 Source
35903
FC273
Y Y Y Y
56230
0x3F65
Channel 16 Source
35903
FC273
Y Y Y Y
56231
0x3F66
Channel 1 Mode
FC187
Y Y Y Y
56232
0x3F67
Channel 2 Mode
FC187
Y Y Y Y
56233
0x3F68
Channel 3 Mode
FC187
Y Y Y Y
56234
0x3F69
Channel 4 Mode
FC187
Y Y Y Y
56235
0x3F6A
Channel 5 Mode
FC187
Y Y Y Y
56236
0x3F6B
Channel 6 Mode
FC187
Y Y Y Y
56237
0x3F6C
Channel 7 Mode
FC187
Y Y Y Y
56238
0x3F6D
Channel 8 Mode
FC187
Y Y Y Y
56239
0x3F6E
Channel 9 Mode
FC187
Y Y Y Y
56240
0x3F6F
Channel 10 Mode
FC187
Y Y Y Y
56241
0x3F70
Channel 11 Mode
FC187
Y Y Y Y
56242
0x3F71
Channel 12 Mode
FC187
Y Y Y Y
56243
0x3F72
Channel 13 Mode
FC187
Y Y Y Y
56244
0x3F73
Channel 14 Mode
FC187
Y Y Y Y
56245
0x3F74
Channel 15 Mode
FC187
Y Y Y Y
56246
0x3F75
Channel 16 Mode
FC187
Y Y Y Y
Channel 8 Source
Y Y Y Y
Fault Report 1
56260
0x3F83
Function
FC126
Y Y Y Y
56261
0x3F84
Pre-Fault Trigger
0xFFFFFFFF
FC142
0x800A02 2
Y Y Y Y
56263
0x3F86
Fault Trigger
0xFFFFFFFF
FC142
0x800002 2
Y Y Y Y
56265
0x3F88
Analog Channel 1
35903
FC273
Y Y Y Y
56266
0x3F89
Analog Channel 2
35903
FC273
Y Y Y Y
56267
0x3F8A
Analog Channel 3
35903
FC273
Y Y Y Y
56268
0x3F8B
Analog Channel 4
35903
FC273
Y Y Y Y
56269
0x3F8C
Analog Channel 5
35903
FC273
Y Y Y Y
56270
0x3F8D
Analog Channel 6
35903
FC273
Y Y Y Y
56271
0x3F8E
Analog Channel 7
35903
FC273
Y Y Y Y
56272
0x3F8F
Analog Channel 8
35903
FC273
Y Y Y Y
56273
0x3F90
Analog Channel 9
35903
FC273
Y Y Y Y
56274
0x3F91
Analog Channel 10
35903
FC273
Y Y Y Y
56275
0x3F92
Analog Channel 11
35903
FC273
Y Y Y Y
56276
0x3F93
Analog Channel 12
35903
FC273
Y Y Y Y
56277
0x3F94
Analog Channel 13
35903
FC273
Y Y Y Y
56278
0x3F95
Analog Channel 14
35903
FC273
Y Y Y Y
56279
0x3F96
Analog Channel 15
35903
FC273
Y Y Y Y
56280
0x3F97
Analog Channel 16
35903
FC273
Y Y Y Y
11-135
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
56281
0x3F98
Analog Channel 17
35903
FC273
Y Y Y Y
56282
0x3F99
Analog Channel 18
35903
FC273
Y Y Y Y
56283
0x3F9A
Analog Channel 19
35903
FC273
Y Y Y Y
56284
0x3F9B
Analog Channel 20
35903
FC273
Y Y Y Y
56285
0x3F9C
Analog Channel 21
35903
FC273
Y Y Y Y
56286
0x3F9D
Analog Channel 22
35903
FC273
Y Y Y Y
56287
0x3F9E
Analog Channel 23
35903
FC273
Y Y Y Y
56288
0x3F9F
Analog Channel 24
35903
FC273
Y Y Y Y
56289
0x3FA0
Analog Channel 25
35903
FC273
Y Y Y Y
56290
0x3FA1
Analog Channel 26
35903
FC273
Y Y Y Y
56291
0x3FA2
Analog Channel 27
35903
FC273
Y Y Y Y
56292
0x3FA3
Analog Channel 28
35903
FC273
Y Y Y Y
56293
0x3FA4
Analog Channel 29
35903
FC273
Y Y Y Y
56294
0x3FA5
Analog Channel 30
35903
FC273
Y Y Y Y
56295
0x3FA6
Analog Channel 31
35903
FC273
Y Y Y Y
56296
0x3FA7
Analog Channel 32
35903
FC273
Y Y Y Y
Y
Fault Locator
56371
0x3FF2
Trigger
0xFFFFFFFF
FC142
56373
0x3FF4
Units of Length
FC268
56374
0x3FF5
Length of Feeder
999
F1
56375
0x3FF6
Length of Feeder
999
56376
0x3FF7
25000
ohms
F1
F2
56377
0x3FF8
25000
ohms
F2
56378
0x3FF9
65000
ohms
F2
56379
0x3FFA
65000
ohms
F2
56380
0x3FFB
VT Substitution
FC269
56381
0x3FFC
9999
ohms
F2
56382
0x3FFD
9999
ohms
F2
65535
F60_26
In Service
13
Y Y Y Y
Programmable LED 1
56400
0x400F
LED 1 Name
56413
0x401C
LED 1 Color
FC157
Y Y Y Y
56414
0x401D
LED 1 Trigger
0xFFFFFFFF
FC142
0x801802 2
Y Y Y Y
56416
0x401F
LED 1 Type
FC199
Y Y Y Y
Programmable LED 2
56417
0x4020
LED 2 Name
65535
F60_26
Trip
13
Y Y Y Y
56430
0x402D
LED 2 Color
FC157
Y Y Y Y
56431
0x402E
LED 2 Trigger
0xFFFFFFFF
FC142
0x800002 2
Y Y Y Y
56433
0x4030
LED 2 Type
FC199
Y Y Y Y
Programmable LED 3
56434
0x4031
LED 3 Name
65535
F60_26
Alarm
13
Y Y Y Y
56447
0x403E
LED 3 Color
FC157
Y Y Y Y
56448
0x403F
LED 3 Trigger
0xFFFFFFFF
FC142
0x800202 2
Y Y Y Y
56450
0x4041
LED 3 Type
FC199
Y Y Y Y
65535
F60_26
Pickup
13
Y Y Y Y
Programmable LED 4
56451
11-136
0x4042
LED 4 Name
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
56464
0x404F
LED 4 Color
FC157
Y Y Y Y
56465
0x4050
LED 4 Trigger
0xFFFFFFFF
FC142
0x800A02 2
Y Y Y Y
56467
0x4052
LED 4 Type
FC199
Y Y Y Y
Programmable LED 5
56468
0x4053
LED 5 Name
65535
F60_26
Test Mode 13
Y Y Y Y
56481
0x4060
LED 5 Color
FC157
Y Y Y Y
56482
0x4061
LED 5 Trigger
0xFFFFFFFF
FC142
0x801A02 2
Y Y Y Y
56484
0x4063
LED 5 Type
FC199
Y Y Y Y
Programmable LED 6
56485
0x4064
LED 6 Name
65535
F60_26
Message
13
Y Y Y Y
56498
0x4071
LED 6 Color
FC157
Y Y Y Y
56499
0x4072
LED 6 Trigger
0xFFFFFFFF
FC142
0x801602 2
Y Y Y Y
56501
0x4074
LED 6 Type
FC199
Y Y Y Y
65535
F60_26
Local
Mode
13
Y Y Y Y
Programmable LED 7
56502
0x4075
LED 7 Name
56515
0x4082
LED 7 Color
FC157
Y Y Y Y
56516
0x4083
LED 7 Trigger
0xFFFFFFFF
FC142
0x81FA08 2
Y Y Y Y
56518
0x4085
LED 7 Type
FC199
Y Y Y Y
Programmable LED 8
56519
0x4086
LED 8 Name
65535
F60_26
BKR Open 13
Y Y Y Y
56532
0x4093
LED 8 Color
FC157
Y Y Y Y
56533
0x4094
LED 8 Trigger
0xFFFFFFFF
FC142
0x803A02 2
Y Y Y Y
56535
0x4096
LED 8 Type
FC199
Y Y Y Y
65535
F60_26
BKR
Closed
13
Y Y Y Y
Programmable LED 9
56536
0x4097
LED 9 Name
56549
0x40A4
LED 9 Color
FC157
Y Y Y Y
56550
0x40A5
LED 9 Trigger
0xFFFFFFFF
FC142
0x803802 2
Y Y Y Y
56552
0x40A7
LED 9 Type
FC199
Y Y Y Y
65535
F60_26
LED 10
13
Y Y Y Y
Programmable LED 10
56553
0x40A8
LED 10 Name
56566
0x40B5
LED 10 Color
FC157
Y Y Y Y
56567
0x40B6
LED 10 Trigger
0xFFFFFFFF
FC142
Y Y Y Y
56569
0x40B8
LED 10 Type
FC199
Y Y Y Y
65535
F60_26
LED 11
13
Y Y Y Y
Programmable LED 11
56570
0x40B9
LED 11 Name
56583
0x40C6
LED 11 Color
FC157
Y Y Y Y
56584
0x40C7
LED 11 Trigger
0xFFFFFFFF
FC142
Y Y Y Y
56586
0x40C9
LED 11 Type
FC199
Y Y Y Y
65535
F60_26
LED 12
13
Y Y Y Y
Programmable LED 12
56587
0x40CA
LED 12 Name
56600
0x40D7
LED 12 Color
FC157
Y Y Y Y
56601
0x40D8
LED 12 Trigger
0xFFFFFFFF
FC142
Y Y Y Y
56603
FC199
Y Y Y Y
Programmable LED 13
11-137
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
56604
65535
F60_26
LED 13
13
Y Y Y Y
56617
0x40E8
LED 13 Color
FC157
Y Y Y Y
56618
0x40E9
LED 13 Trigger
0xFFFFFFFF
FC142
Y Y Y Y
56620
0x40EB
LED 13 Type
FC199
Y Y Y Y
65535
F60_26
LED 14
13
Y Y Y Y
Programmable LED 14
56621
0x40EC
LED 14 Name
56634
0x40F9
LED 14 Color
FC157
Y Y Y Y
56635
0x40FA
LED 14 Trigger
0xFFFFFFFF
FC142
Y Y Y Y
56637
0x40FC
LED 14 Type
FC199
Y Y Y Y
Programmable LED 15
56638
0x40FD
LED 15 Name
65535
F60_26
PB 1
13
Y Y Y Y
56651
0x410A
LED 15 Color
FC157
Y Y Y Y
56652
0x410B
LED 15 Trigger
0xFFFFFFFF
FC142
0x802002 2
Y Y Y Y
56654
0x410D
LED 15 Type
FC199
Y Y Y Y
Programmable LED 16
56655
0x410E
LED 16 Name
65535
F60_26
PB 2
13
Y Y Y Y
56668
0x411B
LED 16 Color
FC157
Y Y Y Y
56669
0x411C
LED 16 Trigger
0xFFFFFFFF
FC142
0x802202 2
Y Y Y Y
56671
0x411E
LED 16 Type
FC199
Y Y Y Y
Programmable LED 17
56672
0x411F
LED 17 Name
65535
F60_26
PB 3
13
Y Y Y Y
56685
0x412C
LED 17 Color
FC157
Y Y Y Y
56686
0x412D
LED 17 Trigger
0xFFFFFFFF
FC142
0x802402 2
Y Y Y Y
56688
0x412F
LED 17 Type
FC199
Y Y Y Y
Programmable Pushbutton 1
56700
0x413B
Function
FC101
56701
0x413C
ID Text
65535
F60_26
Open BKR 13
Y Y Y Y
56714
0x4149
ON Text
65535
F60_26
PB1 On
13
Y Y Y Y
56727
0x4156
OFF Text
65535
F60_26
PB1 Off
13
Y Y Y Y
56740
0x4163
Hold Pressed
100
F1
Y Y Y Y
56741
0x4164
Autoreset
FC126
Y Y Y Y
56742
0x4165
Autoreset Delay
6000
F1
10
Y Y Y Y
56743
0x4166
Lock
0xFFFFFFFF
FC142
Y Y Y Y
56745
0x4168
Dropout Time
6000
56746
0x4169
Events
s
s
s
Y Y Y Y
F1
Y Y Y Y
FC126
Y Y Y Y
Programmable Pushbutton 2
56748
0x416B
Function
FC101
56749
0x416C
ID Text
65535
F60_26
Close BKR 13
Y Y Y Y
Y Y Y Y
56762
0x4179
ON Text
65535
F60_26
PB2 On
13
Y Y Y Y
56775
0x4186
OFF Text
65535
F60_26
PB2 Off
13
Y Y Y Y
56788
0x4193
Hold Pressed
100
F1
Y Y Y Y
56789
0x4194
Autoreset
FC126
Y Y Y Y
56790
0x4195
Autoreset Delay
6000
F1
10
Y Y Y Y
56791
0x4196
Lock
0xFFFFFFFF
FC142
Y Y Y Y
56793
0x4198
Dropout Time
6000
F1
Y Y Y Y
11-138
s
s
s
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
56794
FC126
0x4199
Events
Y Y Y Y
Programmable Pushbutton 3
56796
0x419B
Function
FC101
Y Y Y Y
56797
0x419C
ID Text
65535
F60_26
F1
13
Y Y Y Y
56810
0x41A9
ON Text
65535
F60_26
PB3 On
13
Y Y Y Y
56823
0x41B6
OFF Text
65535
F60_26
PB3 Off
13
Y Y Y Y
56836
0x41C3
Hold Pressed
100
56837
0x41C4
Autoreset
F1
Y Y Y Y
FC126
Y Y Y Y
56838
0x41C5
Autoreset Delay
6000
F1
10
Y Y Y Y
56839
0x41C6
Lock
0xFFFFFFFF
56841
0x41C8
Dropout Time
6000
FC142
Y Y Y Y
F1
56842
0x41C9
Events
Y Y Y Y
FC126
Y Y Y Y
10
F0
Y Y Y Y
56861
10
900
56862
F0
30
Y Y Y Y
FC126A
56864
0x41DF
Temperature Display
Y Y Y Y
FC119
Y Y Y Y
56865
0x41E0
FC126
Y Y Y Y
Function
FC126
Y Y Y Y
s
s
Default Screens
56880
0x41EF
56882
0x41F1
Display Time
900
F0
10
Y Y Y Y
56883
0x41F2
Default Screen 1
95
FC290
Y Y Y Y
56884
0x41F3
Default Screen 2
95
FC290
Y Y Y Y
56885
0x41F4
Default Screen 3
95
FC290
Y Y Y Y
56900
0x4203
Reset Input 1
0xFFFFFFFF
FC142
Y Y Y Y
56902
0x4205
Reset Input 2
0xFFFFFFFF
FC142
Y Y Y Y
56904
0x4207
Reset Input 3
0xFFFFFFFF
FC142
Y Y Y Y
Resetting
Installation
56920
0x4217
Device Name
65535
F60_26
Relay 1
13
Y Y Y Y
56933
0x4224
Device In Service
FC114
Y Y Y Y
56934
0x4225
Service Command
65535
F0
Y Y Y Y
Event Data
56950
0x4235
Parameter 1
35903
FC273
Y Y Y Y
56951
0x4236
Parameter 2
35903
FC273
Y Y Y Y
56952
0x4237
Parameter 3
35903
FC273
Y Y Y Y
56953
0x4238
Parameter 4
35903
FC273
Y Y Y Y
56954
0x4239
Parameter 5
35903
FC273
Y Y Y Y
56955
0x423A
Parameter 6
35903
FC273
Y Y Y Y
56956
0x423B
Parameter 7
35903
FC273
Y Y Y Y
56957
0x423C
Parameter 8
35903
FC273
Y Y Y Y
56958
0x423D
Parameter 9
35903
FC273
Y Y Y Y
56959
0x423E
Parameter 10
35903
FC273
Y Y Y Y
56960
0x423F
Parameter 11
35903
FC273
Y Y Y Y
56961
0x4240
Parameter 12
35903
FC273
Y Y Y Y
11-139
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
56962
0x4241
Parameter 13
35903
FC273
Y Y Y Y
56963
0x4242
Parameter 14
35903
FC273
Y Y Y Y
56964
0x4243
Parameter 15
35903
FC273
Y Y Y Y
56965
0x4244
Parameter 16
35903
FC273
Y Y Y Y
56966
0x4245
Parameter 17
35903
FC273
Y Y Y Y
56967
0x4246
Parameter 18
35903
FC273
Y Y Y Y
56968
0x4247
Parameter 19
35903
FC273
Y Y Y Y
56969
0x4248
Parameter 20
35903
FC273
Y Y Y Y
56970
0x4249
Parameter 21
35903
FC273
Y Y Y Y
56971
0x424A
Parameter 22
35903
FC273
Y Y Y Y
56972
0x424B
Parameter 23
35903
FC273
Y Y Y Y
56973
0x424C
Parameter 24
35903
FC273
Y Y Y Y
56974
0x424D
Parameter 25
35903
FC273
Y Y Y Y
56975
0x424E
Parameter 26
35903
FC273
Y Y Y Y
56976
0x424F
Parameter 27
35903
FC273
Y Y Y Y
56977
0x4250
Parameter 28
35903
FC273
Y Y Y Y
56978
0x4251
Parameter 29
35903
FC273
Y Y Y Y
56979
0x4252
Parameter 30
35903
FC273
Y Y Y Y
56980
0x4253
Parameter 31
35903
FC273
Y Y Y Y
56981
0x4254
Parameter 32
35903
FC273
Y Y Y Y
56982
0x4255
Parameter 33
35903
FC273
Y Y Y Y
56983
0x4256
Parameter 34
35903
FC273
Y Y Y Y
56984
0x4257
Parameter 35
35903
FC273
Y Y Y Y
56985
0x4258
Parameter 36
35903
FC273
Y Y Y Y
56986
0x4259
Parameter 37
35903
FC273
Y Y Y Y
56987
0x425A
Parameter 38
35903
FC273
Y Y Y Y
56988
0x425B
Parameter 39
35903
FC273
Y Y Y Y
56989
0x425C
Parameter 40
35903
FC273
Y Y Y Y
56990
0x425D
Parameter 41
35903
FC273
Y Y Y Y
56991
0x425E
Parameter 42
35903
FC273
Y Y Y Y
56992
0x425F
Parameter 43
35903
FC273
Y Y Y Y
56993
0x4260
Parameter 44
35903
FC273
Y Y Y Y
56994
0x4261
Parameter 45
35903
FC273
Y Y Y Y
56995
0x4262
Parameter 46
35903
FC273
Y Y Y Y
56996
0x4263
Parameter 47
35903
FC273
Y Y Y Y
56997
0x4264
Parameter 48
35903
FC273
Y Y Y Y
56998
0x4265
Parameter 49
35903
FC273
Y Y Y Y
56999
0x4266
Parameter 50
35903
FC273
Y Y Y Y
57000
0x4267
Parameter 51
35903
FC273
Y Y Y Y
57001
0x4268
Parameter 52
35903
FC273
Y Y Y Y
57002
0x4269
Parameter 53
35903
FC273
Y Y Y Y
57003
0x426A
Parameter 54
35903
FC273
Y Y Y Y
57004
0x426B
Parameter 55
35903
FC273
Y Y Y Y
57005
0x426C
Parameter 56
35903
FC273
Y Y Y Y
57006
0x426D
Parameter 57
35903
FC273
Y Y Y Y
11-140
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
57007
0x426E
Parameter 58
35903
FC273
Y Y Y Y
57008
0x426F
Parameter 59
35903
FC273
Y Y Y Y
57009
0x4270
Parameter 60
35903
FC273
Y Y Y Y
57010
0x4271
Parameter 61
35903
FC273
Y Y Y Y
57011
0x4272
Parameter 62
35903
FC273
Y Y Y Y
57012
0x4273
Parameter 63
35903
FC273
Y Y Y Y
57013
0x4274
Parameter 64
35903
FC273
Y Y Y Y
65535
F60_26
BSG3
13
Y Y Y Y
0x42B7
Device Name
57093
0x42C4
Device Type
FC392
Y Y Y Y
57107
0x42D2
IP Address
0xFFFFFFFF
F70
Y Y Y Y
57109
0x42D4
Slave Address
254
F0
254
Y Y Y Y
57110
0x42D5
Modbus Port
10000
F0
502
Y Y Y Y
57111
0x42D6
Poll Mode
FC393
Y Y Y Y
57112
0x42D7
Function
FC186
Y Y Y Y
57113
0x42D8
Poll Rate
120
F0
Y Y Y Y
57114
0x42D9
Trigger
0xFFFFFFFF
FC142
Y Y Y Y
CT Bank Name
65535
F60_26
CT Bank 1 13
-J1
Y Y Y Y
Y Y Y Y
min
Current 1 - J1
59000
0x4A37
59013
0x4A44
Phase CT Primary
12000
59014
0x4A45
Phase CT Secondary
59015
0x4A46
Ground CT Primary
12000
CT Bank Name
65535
A
A
F0
500
FC258
Y Y Y Y
F0
500
Y Y Y Y
F60_26
CT Bank 2 13
-K1
Current 2 - K1
59019
0x4A4A
59032
0x4A57
Phase CT Primary
12000
F0
500
59034
0x4A59
Ground CT Primary
12000
F0
500
59036
0x4A5B
12000
F0
500
F60_26
CT Bank 3 13
-K2
Y Y Y Y
Y Y Y
Y Y
Y Y Y
Current 3 - K2
59038
65535
Y Y
59051
0x4A6A
Phase CT Primary
12000
F0
500
Y Y
59053
0x4A6C
Ground CT Primary
12000
F0
500
Y Y
Voltage 1 - J2
59070
65535
F60_26
Ph VT
Bnk1-J2
13
Y Y Y Y
59083
0x4A8A
FC106
Y Y Y Y
Phase VT Connection
59084
0x4A8B
Phase VT Secondary
100
2400
F1
1200
Y Y Y Y
59085
0x4A8C
Phase VT Ratio
100
500000
F12
100
Y Y Y Y
59087
0x4A8E
Aux. VT Name
65535
F60_26
Ax VT
Bnk1-J2
13
Y Y Y Y
59100
0x4A9B
Aux. VT Connection
FC176
Y Y Y Y
59101
0x4A9C
Aux. VT Secondary
100
2400
F1
1200
Y Y Y Y
59102
100
500000
F12
100
Y Y Y Y
Voltage 2 - K2
11-141
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
59104
0x4A9F
65535
F60_26
Ph VT
Bnk2-K2
13
59117
0x4AAC
Phase VT Connection
FC106
59118
100
2400
F1
1200
59119
0x4AAE
Phase VT Ratio
100
500000
F12
100
59121
0x4AB0
Aux. VT Name
65535
F60_26
Ax VT
Bnk2-K2
13
59134
FC176
59135
0x4ABE
Aux. VT Secondary
100
2400
F1
1200
59136
0x4ABF
Aux. VT Ratio
100
500000
F12
100
FC259
Y Y
FC259
Power Sensing 1
59152
0x4ACF
Power Sensing 2
59157
Power System
59170
0x4AE1
Nominal Frequency
FC107
Y Y Y Y
59171
0x4AE2
Phase Rotation
FC124A
Y Y Y Y
59174
0x4AE5
Frequency Tracking
FC126
Y Y Y Y
Y
59175
0x4AE6
Cost of Energy
1000
59178
0x4AE9
0x12
0x22
c/kWh
F1
50
FC103A
0x12
F0
100
F2
100
Motor Setup
59190
0x4AF5
5000
59191
0x4AF6
100
150
59192
0x4AF7
50000
F0
600
59193
0x4AF8
Emergency Restart
0xFFFFFFFF
FC142
59195
0x4AFA
F0
59196
0x4AFB
90
59197
0x4AFC
59198
0x4AFD
32
F0
59199
0x4AFE
FC126
59200
0x4AFF
0xFFFFFFFF
FC142
59202
0x4B01
60000
F2
500
59203
0x4B02
Speed2 CT Primary
12000
F0
500
59204
0x4B03
5000
F0
100
F0
Hp
F0
4000
59205
0x4B04
Number of Poles
64
59206
0x4B05
Motor Horsepower
100
15000
min
cycles
F0
15
FC137
VFD
59230
0x4B1D Function
FC126
59231
0x4B1E
Bypass Switch
0xFFFFFFFF
FC142
59233
0x4B20
Starting Frequency
30
720
Hz
F1
100
100000
hrs
F10
0x4B31
59252
0x4B33
4294967295
MWh
F13
59254
0x4B35
4294967295
MWh
F13
59256
0x4B37
4294967295
Mvarh
F13
11-142
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
59258
4294967295
F13
FC369
F13
100000
0x4B39
Mvarh
0x4B4F
Phase Compensation
59281
0x4B50
20000000
59283
0x4B52
59284
0x4B53
No Load loss
20000000
59286
0x4B55
Type of Cooling
59287
0x4B56
200
59288
0x4B57
59289
0x4B58
59290
0x4B59
59291
0x4B5A
kW
FC367
kW
F13
10000
FC368
?C
F0
35
20000
kWh/?C F2
100
25
1500
min
F2
200
Energization Winding
Source
FC102A
Year of Manufacture
1950
2100
F0
1950
FC102
Y Y
Transformer Winding 1
59310
59311
0x4B6E
Rated MVA
2000000
MVA
F13
5000
Y Y
59313
0x4B70
1000000
kV
F13
13800
Y Y
59315
0x4B72
Connection
FC375
Y Y
59317
0x4B74
Grounding
FC376
Y Y
59318
0x4B75
1000000
F14
100000
Y Y
ohms
Transformer Winding 2
59326
FC102
Y Y
59327
0x4B7E
Rated MVA
2000000
MVA
F13
5000
Y Y
59329
0x4B80
1000000
kV
F13
13800
Y Y
59331
0x4B82
Connection
FC375
Y Y
59332
0x4B83
11
FC377
Y Y
59333
0x4B84
Grounding
FC376
Y Y
59334
0x4B85
1000000
F14
100000
Y Y
ohms
Transformer Winding 3
59342
FC102
59343
0x4B8E
Rated MVA
2000000
MVA
F13
5000
59345
0x4B90
1000000
kV
F13
13800
59347
0x4B92
Connection
FC375
59348
0x4B93
11
FC377
59349
0x4B94
Grounding
FC376
59350
0x4B95
1000000
F14
100000
ohms
0x4BB3
Sensing by Breakers
Open
FC126
59381
0x4BB4
0xFFFFFFFF
FC142
59383
0x4BB6
Sensing by Voltage
0x22
FC103E
59384
0x4BB7
Minimum Voltage
50
99
F2
85
59385
0x4BB8
Current Supervision
FC126
59386
0x4BB9
Minimum Current
20
500
F3
50
x VT
x CT
Thermal Inputs
11-143
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
59400
0x4BC7
Winding Currents
FC102A
59401
0x4BC8
Ambient Temperature
30
FC370
59402
0x4BC9
-60
60
?C
F20
-20
59403
-60
60
?C
F20
-20
59404
-60
60
?C
F20
-10
59405
-60
60
?C
F20
10
59406
60
?C
F20
20
59407
0x4BCE
-60
60
?C
F20
30
59408
0x4BCF
-60
60
?C
F20
30
59409
-60
60
?C
F20
30
59410
-60
60
?C
F20
20
59411
-60
60
?C
F20
10
59412
-60
60
?C
F20
10
59413
-60
60
?C
F20
-10
59414
30
FC371
FC126
Tap Changer
59430
0x4BE5
59431
0x4BE6
TC Winding Currents
FC102B
59432
0x4BE7
FC372
59433
0x4BE8
Min Tap
-19
35
F20
-16
59434
0x4BE9
Neutral Tap
-17
37
F20
59435
0x4BEA
Max Tap
39
F0
16
59436
0x4BEB
2000000
kV
F12
6100
59438
2000
kV
F2
50
59439
0x4BEE
5100
ohms
F0
33
59440
0x4BEF
5100
ohms
F0
1089
59441
0x4BF0
20000
mA
F3
4000
59442
0x4BF1
20000
mA
F3
18000
59443
0x4BF2
0xF1F
FC241
59445
0x4BF4
0xF1F
FC241
59447
0x4BF6
0xF1F
FC241
59449
0x4BF8
0xF1F
FC241
59451
0x4BFA
0xF1F
FC241
59453
0x4BFC
0xF1F
FC241
59455
0x4BFE
FC126
59456
0x4BFF
Events
FC126
59457
0x4C00
Targets
FC101
F13
50000
F2
85
2000000
59472
0x4C0F
99
MVA
59473
0x4C10
Rated Phase-Phase
Voltage
300000
F11
138000
59475
0x4C12
90
min
F0
15
Name
65535
F60_26
BKR1
13
Breaker Settings 1
59490
11-144
0x4C21
Y Y Y Y
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
59503
0x21F
FC266
0x4C2E
Y Y Y Y
59505
0x4C30
0x21F
FC266
Y Y Y Y
59507
0x4C32
Connected
0x21F
FC266
Y Y Y Y
59509
0x4C34
0xFFFFFFFF
FC198F
Y Y
59511
0x4C36
0xFFFFFFFF
FC198G 2
Y Y Y Y
Breaker Settings 2
59523
0x4C42
Name
65535
F60_26
BKR2
13
Y Y
59536
0x4C4F
0x21F
FC266
Y Y
59538
0x4C51
0x21F
FC266
Y Y
59540
0x4C53
Connected
0x21F
FC266
Y Y
59542
0x4C55
0xFFFFFFFF
FC198F
Y Y
59544
0x4C57
0xFFFFFFFF
FC198G 0
Y Y
Breaker Settings 3
59556
0x4C63
Name
65535
F60_26
BKR3
13
59569
0x4C70
0x21F
FC266
59571
0x4C72
0x21F
FC266
59573
0x4C74
Connected
0x21F
FC266
59575
0x4C76
0xFFFFFFFF
FC198F
59577
0x4C78
0xFFFFFFFF
FC198G 0
F60_26
FlexCurve 13
A
Y Y Y Y
FlexCurve 1
59610
0x4C99
FlexCurve Name
65535
59623
0x4CA6
FlexCurve A Time
0.00xPKP
6000000
ms
F10
Y Y Y Y
59625
0x4CA8
FlexCurve A Time
0.05xPKP
6000000
ms
F10
Y Y Y Y
59627
6000000
ms
F10
Y Y Y Y
59629
6000000
ms
F10
Y Y Y Y
59631
0x4CAE
FlexCurve A Time
0.20xPKP
6000000
ms
F10
Y Y Y Y
59633
0x4CB0
FlexCurve A Time
0.25xPKP
6000000
ms
F10
Y Y Y Y
59635
0x4CB2
FlexCurve A Time
0.30xPKP
6000000
ms
F10
Y Y Y Y
59637
0x4CB4
FlexCurve A Time
0.35xPKP
6000000
ms
F10
Y Y Y Y
59639
0x4CB6
FlexCurve A Time
0.40xPKP
6000000
ms
F10
Y Y Y Y
59641
0x4CB8
FlexCurve A Time
0.45xPKP
6000000
ms
F10
Y Y Y Y
59643
6000000
ms
F10
Y Y Y Y
59645
6000000
ms
F10
Y Y Y Y
59647
0x4CBE
FlexCurve A Time
0.52xPKP
6000000
ms
F10
Y Y Y Y
59649
0x4CC0
FlexCurve A Time
0.54xPKP
6000000
ms
F10
Y Y Y Y
11-145
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
59651
0x4CC2
FlexCurve A Time
0.56xPKP
6000000
ms
F10
Y Y Y Y
59653
0x4CC4
FlexCurve A Time
0.58xPKP
6000000
ms
F10
Y Y Y Y
59655
0x4CC6
FlexCurve A Time
0.60xPKP
6000000
ms
F10
Y Y Y Y
59657
0x4CC8
FlexCurve A Time
0.62xPKP
6000000
ms
F10
Y Y Y Y
59659
6000000
ms
F10
Y Y Y Y
59661
6000000
ms
F10
Y Y Y Y
59663
0x4CCE
FlexCurve A Time
0.68xPKP
6000000
ms
F10
Y Y Y Y
59665
6000000
ms
F10
Y Y Y Y
59667
6000000
ms
F10
Y Y Y Y
59669
6000000
ms
F10
Y Y Y Y
59671
6000000
ms
F10
Y Y Y Y
59673
6000000
ms
F10
Y Y Y Y
59675
6000000
ms
F10
Y Y Y Y
59677
6000000
ms
F10
Y Y Y Y
59679
6000000
ms
F10
Y Y Y Y
59681
0x4CE0
FlexCurve A Time
0.86xPKP
6000000
ms
F10
Y Y Y Y
59683
0x4CE2
FlexCurve A Time
0.88xPKP
6000000
ms
F10
Y Y Y Y
59685
0x4CE4
FlexCurve A Time
0.90xPKP
6000000
ms
F10
Y Y Y Y
59687
0x4CE6
FlexCurve A Time
0.91xPKP
6000000
ms
F10
Y Y Y Y
59689
0x4CE8
FlexCurve A Time
0.92xPKP
6000000
ms
F10
Y Y Y Y
59691
0x4CEA
FlexCurve A Time
0.93xPKP
6000000
ms
F10
Y Y Y Y
59693
0x4CEC
FlexCurve A Time
0.94xPKP
6000000
ms
F10
Y Y Y Y
59695
0x4CEE
FlexCurve A Time
0.95xPKP
6000000
ms
F10
Y Y Y Y
59697
0x4CF0
FlexCurve A Time
0.96xPKP
6000000
ms
F10
Y Y Y Y
59699
0x4CF2
FlexCurve A Time
0.97xPKP
6000000
ms
F10
Y Y Y Y
59701
0x4CF4
FlexCurve A Time
0.98xPKP
6000000
ms
F10
Y Y Y Y
59703
0x4CF6
FlexCurve A Time
1.03xPKP
6000000
ms
F10
Y Y Y Y
59705
0x4CF8
FlexCurve A Time
1.05xPKP
6000000
ms
F10
Y Y Y Y
11-146
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
59707
0x4CFA
6000000
ms
F10
Y Y Y Y
59709
0x4CFC
6000000
ms
F10
Y Y Y Y
59711
0x4CFE
6000000
ms
F10
Y Y Y Y
59713
0x4D00
6000000
ms
F10
Y Y Y Y
59715
0x4D02
6000000
ms
F10
Y Y Y Y
59717
0x4D04
6000000
ms
F10
Y Y Y Y
59719
0x4D06
6000000
ms
F10
Y Y Y Y
59721
0x4D08
6000000
ms
F10
Y Y Y Y
59723
6000000
ms
F10
Y Y Y Y
59725
6000000
ms
F10
Y Y Y Y
59727
0x4D0E
6000000
ms
F10
Y Y Y Y
59729
0x4D10
6000000
ms
F10
Y Y Y Y
59731
0x4D12
6000000
ms
F10
Y Y Y Y
59733
0x4D14
6000000
ms
F10
Y Y Y Y
59735
0x4D16
6000000
ms
F10
Y Y Y Y
59737
0x4D18
6000000
ms
F10
Y Y Y Y
59739
6000000
ms
F10
Y Y Y Y
59741
6000000
ms
F10
Y Y Y Y
59743
0x4D1E
6000000
ms
F10
Y Y Y Y
59745
0x4D20
6000000
ms
F10
Y Y Y Y
59747
0x4D22
6000000
ms
F10
Y Y Y Y
59749
0x4D24
6000000
ms
F10
Y Y Y Y
59751
0x4D26
6000000
ms
F10
Y Y Y Y
59753
0x4D28
6000000
ms
F10
Y Y Y Y
59755
6000000
ms
F10
Y Y Y Y
59757
6000000
ms
F10
Y Y Y Y
59759
0x4D2E
6000000
ms
F10
Y Y Y Y
59761
0x4D30
6000000
ms
F10
Y Y Y Y
59763
0x4D32
6000000
ms
F10
Y Y Y Y
59765
0x4D34
6000000
ms
F10
Y Y Y Y
59767
0x4D36
6000000
ms
F10
Y Y Y Y
59769
0x4D38
6000000
ms
F10
Y Y Y Y
59771
6000000
ms
F10
Y Y Y Y
59773
6000000
ms
F10
Y Y Y Y
59775
0x4D3E
6000000
ms
F10
Y Y Y Y
59777
0x4D40
6000000
ms
F10
Y Y Y Y
59779
0x4D42
6000000
ms
F10
Y Y Y Y
59781
0x4D44
6000000
ms
F10
Y Y Y Y
59783
0x4D46
6000000
ms
F10
Y Y Y Y
59785
0x4D48
6000000
ms
F10
Y Y Y Y
59787
6000000
ms
F10
Y Y Y Y
59789
6000000
ms
F10
Y Y Y Y
59791
0x4D4E
6000000
ms
F10
Y Y Y Y
59793
0x4D50
6000000
ms
F10
Y Y Y Y
59795
0x4D52
6000000
ms
F10
Y Y Y Y
11-147
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
59797
0x4D54
6000000
ms
F10
Y Y Y Y
59799
0x4D56
6000000
ms
F10
Y Y Y Y
59801
0x4D58
6000000
ms
F10
Y Y Y Y
59803
6000000
ms
F10
Y Y Y Y
59805
6000000
ms
F10
Y Y Y Y
59807
0x4D5E
6000000
ms
F10
Y Y Y Y
59809
0x4D60
6000000
ms
F10
Y Y Y Y
59811
0x4D62
6000000
ms
F10
Y Y Y Y
59813
0x4D64
6000000
ms
F10
Y Y Y Y
59815
0x4D66
6000000
ms
F10
Y Y Y Y
59817
0x4D68
6000000
ms
F10
Y Y Y Y
59819
6000000
ms
F10
Y Y Y Y
59821
6000000
ms
F10
Y Y Y Y
59823
0x4D6E
FlexCurve A Time
10.5xPKP
6000000
ms
F10
Y Y Y Y
59825
0x4D70
FlexCurve A Time
11.0xPKP
6000000
ms
F10
Y Y Y Y
59827
0x4D72
FlexCurve A Time
11.5xPKP
6000000
ms
F10
Y Y Y Y
59829
0x4D74
FlexCurve A Time
12.0xPKP
6000000
ms
F10
Y Y Y Y
59831
0x4D76
FlexCurve A Time
12.5xPKP
6000000
ms
F10
Y Y Y Y
59833
0x4D78
FlexCurve A Time
13.0xPKP
6000000
ms
F10
Y Y Y Y
59835
6000000
ms
F10
Y Y Y Y
59837
6000000
ms
F10
Y Y Y Y
59839
0x4D7E
FlexCurve A Time
14.5xPKP
6000000
ms
F10
Y Y Y Y
59841
0x4D80
FlexCurve A Time
15.0xPKP
6000000
ms
F10
Y Y Y Y
59843
0x4D82
FlexCurve A Time
15.5xPKP
6000000
ms
F10
Y Y Y Y
59845
0x4D84
FlexCurve A Time
16.0xPKP
6000000
ms
F10
Y Y Y Y
59847
0x4D86
FlexCurve A Time
16.5xPKP
6000000
ms
F10
Y Y Y Y
59849
0x4D88
FlexCurve A Time
17.0xPKP
6000000
ms
F10
Y Y Y Y
59851
6000000
ms
F10
Y Y Y Y
59853
6000000
ms
F10
Y Y Y Y
59855
0x4D8E
FlexCurve A Time
18.5xPKP
6000000
ms
F10
Y Y Y Y
59857
0x4D90
FlexCurve A Time
19.0xPKP
6000000
ms
F10
Y Y Y Y
59859
0x4D92
FlexCurve A Time
19.5xPKP
6000000
ms
F10
Y Y Y Y
11-148
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
59861
FlexCurve A Time
20.0xPKP
6000000
F10
FlexCurve Name
65535
F60_26
FlexCurve 13
B
Y Y Y Y
0x4D94
ms
Y Y Y Y
FlexCurve 2
59863
0x4D96
59876
6000000
ms
F10
Y Y Y Y
59878
6000000
ms
F10
Y Y Y Y
59880
6000000
ms
F10
Y Y Y Y
59882
6000000
ms
F10
Y Y Y Y
59884
6000000
ms
F10
Y Y Y Y
59886
6000000
ms
F10
Y Y Y Y
59888
0x4DAF
FlexCurve B Time
0.30xPKP
6000000
ms
F10
Y Y Y Y
59890
6000000
ms
F10
Y Y Y Y
59892
6000000
ms
F10
Y Y Y Y
59894
6000000
ms
F10
Y Y Y Y
59896
6000000
ms
F10
Y Y Y Y
59898
6000000
ms
F10
Y Y Y Y
59900
6000000
ms
F10
Y Y Y Y
59902
6000000
ms
F10
Y Y Y Y
59904
0x4DBF
FlexCurve B Time
0.56xPKP
6000000
ms
F10
Y Y Y Y
59906
6000000
ms
F10
Y Y Y Y
59908
6000000
ms
F10
Y Y Y Y
59910
6000000
ms
F10
Y Y Y Y
59912
6000000
ms
F10
Y Y Y Y
59914
6000000
ms
F10
Y Y Y Y
59916
6000000
ms
F10
Y Y Y Y
59918
6000000
ms
F10
Y Y Y Y
59920
6000000
ms
F10
Y Y Y Y
59922
6000000
ms
F10
Y Y Y Y
59924
6000000
ms
F10
Y Y Y Y
11-149
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
59926
6000000
ms
F10
Y Y Y Y
59928
6000000
ms
F10
Y Y Y Y
59930
6000000
ms
F10
Y Y Y Y
59932
6000000
ms
F10
Y Y Y Y
59934
6000000
ms
F10
Y Y Y Y
59936
6000000
ms
F10
Y Y Y Y
59938
0x4DE1
FlexCurve B Time
0.90xPKP
6000000
ms
F10
Y Y Y Y
59940
0x4DE3
FlexCurve B Time
0.91xPKP
6000000
ms
F10
Y Y Y Y
59942
0x4DE5
FlexCurve B Time
0.92xPKP
6000000
ms
F10
Y Y Y Y
59944
0x4DE7
FlexCurve B Time
0.93xPKP
6000000
ms
F10
Y Y Y Y
59946
0x4DE9
FlexCurve B Time
0.94xPKP
6000000
ms
F10
Y Y Y Y
59948
6000000
ms
F10
Y Y Y Y
59950
6000000
ms
F10
Y Y Y Y
59952
0x4DEF
FlexCurve B Time
0.97xPKP
6000000
ms
F10
Y Y Y Y
59954
0x4DF1
FlexCurve B Time
0.98xPKP
6000000
ms
F10
Y Y Y Y
59956
0x4DF3
FlexCurve B Time
1.03xPKP
6000000
ms
F10
Y Y Y Y
59958
0x4DF5
FlexCurve B Time
1.05xPKP
6000000
ms
F10
Y Y Y Y
59960
0x4DF7
6000000
ms
F10
Y Y Y Y
59962
0x4DF9
6000000
ms
F10
Y Y Y Y
59964
0x4DFB
6000000
ms
F10
Y Y Y Y
59966
6000000
ms
F10
Y Y Y Y
59968
0x4DFF
6000000
ms
F10
Y Y Y Y
59970
0x4E01
6000000
ms
F10
Y Y Y Y
59972
0x4E03
6000000
ms
F10
Y Y Y Y
59974
0x4E05
6000000
ms
F10
Y Y Y Y
59976
0x4E07
6000000
ms
F10
Y Y Y Y
59978
0x4E09
6000000
ms
F10
Y Y Y Y
59980
0x4E0B
6000000
ms
F10
Y Y Y Y
59982
0x4E0D
6000000
ms
F10
Y Y Y Y
59984
0x4E0F
6000000
ms
F10
Y Y Y Y
59986
0x4E11
6000000
ms
F10
Y Y Y Y
59988
0x4E13
6000000
ms
F10
Y Y Y Y
59990
0x4E15
6000000
ms
F10
Y Y Y Y
59992
0x4E17
6000000
ms
F10
Y Y Y Y
59994
0x4E19
6000000
ms
F10
Y Y Y Y
11-150
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
6000000
F10
59996
0x4E1B
59998
0x4E1D
6000000
ms
F10
Y Y Y Y
60000
0x4E1F
6000000
ms
F10
Y Y Y Y
60002
0x4E21
6000000
ms
F10
Y Y Y Y
60004
0x4E23
6000000
ms
F10
Y Y Y Y
60006
0x4E25
6000000
ms
F10
Y Y Y Y
60008
0x4E27
6000000
ms
F10
Y Y Y Y
60010
0x4E29
6000000
ms
F10
Y Y Y Y
60012
0x4E2B
6000000
ms
F10
Y Y Y Y
60014
0x4E2D
6000000
ms
F10
Y Y Y Y
60016
0x4E2F
6000000
ms
F10
Y Y Y Y
60018
0x4E31
6000000
ms
F10
Y Y Y Y
60020
0x4E33
6000000
ms
F10
Y Y Y Y
60022
0x4E35
6000000
ms
F10
Y Y Y Y
60024
0x4E37
6000000
ms
F10
Y Y Y Y
60026
0x4E39
6000000
ms
F10
Y Y Y Y
60028
0x4E3B
6000000
ms
F10
Y Y Y Y
60030
0x4E3D
6000000
ms
F10
Y Y Y Y
60032
0x4E3F
6000000
ms
F10
Y Y Y Y
60034
0x4E41
6000000
ms
F10
Y Y Y Y
60036
0x4E43
6000000
ms
F10
Y Y Y Y
60038
0x4E45
6000000
ms
F10
Y Y Y Y
60040
0x4E47
6000000
ms
F10
Y Y Y Y
60042
0x4E49
6000000
ms
F10
Y Y Y Y
60044
0x4E4B
6000000
ms
F10
Y Y Y Y
60046
0x4E4D
6000000
ms
F10
Y Y Y Y
60048
0x4E4F
6000000
ms
F10
Y Y Y Y
60050
0x4E51
6000000
ms
F10
Y Y Y Y
60052
0x4E53
6000000
ms
F10
Y Y Y Y
60054
0x4E55
6000000
ms
F10
Y Y Y Y
60056
0x4E57
6000000
ms
F10
Y Y Y Y
60058
0x4E59
6000000
ms
F10
Y Y Y Y
60060
0x4E5B
6000000
ms
F10
Y Y Y Y
60062
0x4E5D
6000000
ms
F10
Y Y Y Y
60064
0x4E5F
6000000
ms
F10
Y Y Y Y
60066
0x4E61
6000000
ms
F10
Y Y Y Y
60068
0x4E63
6000000
ms
F10
Y Y Y Y
60070
0x4E65
6000000
ms
F10
Y Y Y Y
60072
0x4E67
6000000
ms
F10
Y Y Y Y
60074
0x4E69
FlexCurve B Time
10.0xPKP
6000000
ms
F10
Y Y Y Y
60076
0x4E6B
FlexCurve B Time
10.5xPKP
6000000
ms
F10
Y Y Y Y
60078
0x4E6D
FlexCurve B Time
11.0xPKP
6000000
ms
F10
Y Y Y Y
60080
0x4E6F
FlexCurve B Time
11.5xPKP
6000000
ms
F10
Y Y Y Y
ms
Y Y Y Y
11-151
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
60082
0x4E71
FlexCurve B Time
12.0xPKP
6000000
ms
F10
Y Y Y Y
60084
0x4E73
FlexCurve B Time
12.5xPKP
6000000
ms
F10
Y Y Y Y
60086
0x4E75
FlexCurve B Time
13.0xPKP
6000000
ms
F10
Y Y Y Y
60088
0x4E77
FlexCurve B Time
13.5xPKP
6000000
ms
F10
Y Y Y Y
60090
0x4E79
FlexCurve B Time
14.0xPKP
6000000
ms
F10
Y Y Y Y
60092
0x4E7B
FlexCurve B Time
14.5xPKP
6000000
ms
F10
Y Y Y Y
60094
0x4E7D
FlexCurve B Time
15.0xPKP
6000000
ms
F10
Y Y Y Y
60096
0x4E7F
FlexCurve B Time
15.5xPKP
6000000
ms
F10
Y Y Y Y
60098
0x4E81
FlexCurve B Time
16.0xPKP
6000000
ms
F10
Y Y Y Y
60100
0x4E83
FlexCurve B Time
16.5xPKP
6000000
ms
F10
Y Y Y Y
60102
0x4E85
FlexCurve B Time
17.0xPKP
6000000
ms
F10
Y Y Y Y
60104
0x4E87
FlexCurve B Time
17.5xPKP
6000000
ms
F10
Y Y Y Y
60106
0x4E89
FlexCurve B Time
18.0xPKP
6000000
ms
F10
Y Y Y Y
60108
0x4E8B
FlexCurve B Time
18.5xPKP
6000000
ms
F10
Y Y Y Y
60110
0x4E8D
FlexCurve B Time
19.0xPKP
6000000
ms
F10
Y Y Y Y
60112
0x4E8F
FlexCurve B Time
19.5xPKP
6000000
ms
F10
Y Y Y Y
60114
0x4E91
FlexCurve B Time
20.0xPKP
6000000
ms
F10
Y Y Y Y
F60_26
FlexCurve 13
C
Y Y Y Y
FlexCurve 3
60116
0x4E93
FlexCurve Name
65535
60129
0x4EA0
FlexCurve C Time
0.00xPKP
6000000
ms
F10
Y Y Y Y
60131
0x4EA2
FlexCurve C Time
0.05xPKP
6000000
ms
F10
Y Y Y Y
60133
0x4EA4
FlexCurve C Time
0.10xPKP
6000000
ms
F10
Y Y Y Y
60135
0x4EA6
FlexCurve C Time
0.15xPKP
6000000
ms
F10
Y Y Y Y
60137
0x4EA8
FlexCurve C Time
0.20xPKP
6000000
ms
F10
Y Y Y Y
60139
0x4EAA
FlexCurve C Time
0.25xPKP
6000000
ms
F10
Y Y Y Y
60141
0x4EAC
FlexCurve C Time
0.30xPKP
6000000
ms
F10
Y Y Y Y
60143
0x4EAE
FlexCurve C Time
0.35xPKP
6000000
ms
F10
Y Y Y Y
60145
0x4EB0
FlexCurve C Time
0.40xPKP
6000000
ms
F10
Y Y Y Y
11-152
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
60147
0x4EB2
FlexCurve C Time
0.45xPKP
6000000
ms
F10
Y Y Y Y
60149
0x4EB4
FlexCurve C Time
0.48xPKP
6000000
ms
F10
Y Y Y Y
60151
0x4EB6
FlexCurve C Time
0.50xPKP
6000000
ms
F10
Y Y Y Y
60153
0x4EB8
FlexCurve C Time
0.52xPKP
6000000
ms
F10
Y Y Y Y
60155
0x4EBA
FlexCurve C Time
0.54xPKP
6000000
ms
F10
Y Y Y Y
60157
0x4EBC
FlexCurve C Time
0.56xPKP
6000000
ms
F10
Y Y Y Y
60159
0x4EBE
FlexCurve C Time
0.58xPKP
6000000
ms
F10
Y Y Y Y
60161
0x4EC0
FlexCurve C Time
0.60xPKP
6000000
ms
F10
Y Y Y Y
60163
0x4EC2
FlexCurve C Time
0.62xPKP
6000000
ms
F10
Y Y Y Y
60165
0x4EC4
FlexCurve C Time
0.64xPKP
6000000
ms
F10
Y Y Y Y
60167
0x4EC6
FlexCurve C Time
0.66xPKP
6000000
ms
F10
Y Y Y Y
60169
0x4EC8
FlexCurve C Time
0.68xPKP
6000000
ms
F10
Y Y Y Y
60171
0x4ECA
FlexCurve C Time
0.70xPKP
6000000
ms
F10
Y Y Y Y
60173
0x4ECC
FlexCurve C Time
0.72xPKP
6000000
ms
F10
Y Y Y Y
60175
0x4ECE
FlexCurve C Time
0.74xPKP
6000000
ms
F10
Y Y Y Y
60177
0x4ED0
FlexCurve C Time
0.76xPKP
6000000
ms
F10
Y Y Y Y
60179
0x4ED2
FlexCurve C Time
0.78xPKP
6000000
ms
F10
Y Y Y Y
60181
0x4ED4
FlexCurve C Time
0.80xPKP
6000000
ms
F10
Y Y Y Y
60183
0x4ED6
FlexCurve C Time
0.82xPKP
6000000
ms
F10
Y Y Y Y
60185
0x4ED8
FlexCurve C Time
0.84xPKP
6000000
ms
F10
Y Y Y Y
60187
0x4EDA
FlexCurve C Time
0.86xPKP
6000000
ms
F10
Y Y Y Y
60189
6000000
ms
F10
Y Y Y Y
60191
0x4EDE
FlexCurve C Time
0.90xPKP
6000000
ms
F10
Y Y Y Y
60193
0x4EE0
FlexCurve C Time
0.91xPKP
6000000
ms
F10
Y Y Y Y
60195
0x4EE2
FlexCurve C Time
0.92xPKP
6000000
ms
F10
Y Y Y Y
60197
0x4EE4
FlexCurve C Time
0.93xPKP
6000000
ms
F10
Y Y Y Y
60199
0x4EE6
FlexCurve C Time
0.94xPKP
6000000
ms
F10
Y Y Y Y
60201
0x4EE8
FlexCurve C Time
0.95xPKP
6000000
ms
F10
Y Y Y Y
11-153
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
60203
0x4EEA
FlexCurve C Time
0.96xPKP
6000000
ms
F10
Y Y Y Y
60205
0x4EEC
FlexCurve C Time
0.97xPKP
6000000
ms
F10
Y Y Y Y
60207
0x4EEE
FlexCurve C Time
0.98xPKP
6000000
ms
F10
Y Y Y Y
60209
0x4EF0
FlexCurve C Time
1.03xPKP
6000000
ms
F10
Y Y Y Y
60211
0x4EF2
FlexCurve C Time
1.05xPKP
6000000
ms
F10
Y Y Y Y
60213
0x4EF4
6000000
ms
F10
Y Y Y Y
60215
0x4EF6
6000000
ms
F10
Y Y Y Y
60217
0x4EF8
6000000
ms
F10
Y Y Y Y
60219
0x4EFA
6000000
ms
F10
Y Y Y Y
60221
0x4EFC
6000000
ms
F10
Y Y Y Y
60223
0x4EFE
6000000
ms
F10
Y Y Y Y
60225
0x4F00
6000000
ms
F10
Y Y Y Y
60227
0x4F02
6000000
ms
F10
Y Y Y Y
60229
0x4F04
6000000
ms
F10
Y Y Y Y
60231
0x4F06
6000000
ms
F10
Y Y Y Y
60233
0x4F08
6000000
ms
F10
Y Y Y Y
60235
0x4F0A
6000000
ms
F10
Y Y Y Y
60237
0x4F0C
6000000
ms
F10
Y Y Y Y
60239
0x4F0E
6000000
ms
F10
Y Y Y Y
60241
0x4F10
6000000
ms
F10
Y Y Y Y
60243
0x4F12
6000000
ms
F10
Y Y Y Y
60245
0x4F14
6000000
ms
F10
Y Y Y Y
60247
0x4F16
6000000
ms
F10
Y Y Y Y
60249
0x4F18
6000000
ms
F10
Y Y Y Y
60251
0x4F1A
6000000
ms
F10
Y Y Y Y
60253
0x4F1C
6000000
ms
F10
Y Y Y Y
60255
0x4F1E
6000000
ms
F10
Y Y Y Y
60257
0x4F20
6000000
ms
F10
Y Y Y Y
60259
0x4F22
6000000
ms
F10
Y Y Y Y
60261
0x4F24
6000000
ms
F10
Y Y Y Y
60263
0x4F26
6000000
ms
F10
Y Y Y Y
60265
0x4F28
6000000
ms
F10
Y Y Y Y
60267
0x4F2A
6000000
ms
F10
Y Y Y Y
60269
0x4F2C
6000000
ms
F10
Y Y Y Y
60271
0x4F2E
6000000
ms
F10
Y Y Y Y
60273
0x4F30
6000000
ms
F10
Y Y Y Y
60275
0x4F32
6000000
ms
F10
Y Y Y Y
60277
0x4F34
6000000
ms
F10
Y Y Y Y
60279
0x4F36
6000000
ms
F10
Y Y Y Y
60281
0x4F38
6000000
ms
F10
Y Y Y Y
60283
0x4F3A
6000000
ms
F10
Y Y Y Y
60285
0x4F3C
6000000
ms
F10
Y Y Y Y
11-154
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
60287
0x4F3E
6000000
ms
F10
Y Y Y Y
60289
0x4F40
6000000
ms
F10
Y Y Y Y
60291
0x4F42
6000000
ms
F10
Y Y Y Y
60293
0x4F44
6000000
ms
F10
Y Y Y Y
60295
0x4F46
6000000
ms
F10
Y Y Y Y
60297
0x4F48
6000000
ms
F10
Y Y Y Y
60299
0x4F4A
6000000
ms
F10
Y Y Y Y
60301
0x4F4C
6000000
ms
F10
Y Y Y Y
60303
0x4F4E
6000000
ms
F10
Y Y Y Y
60305
0x4F50
6000000
ms
F10
Y Y Y Y
60307
0x4F52
6000000
ms
F10
Y Y Y Y
60309
0x4F54
6000000
ms
F10
Y Y Y Y
60311
0x4F56
6000000
ms
F10
Y Y Y Y
60313
0x4F58
6000000
ms
F10
Y Y Y Y
60315
0x4F5A
6000000
ms
F10
Y Y Y Y
60317
0x4F5C
6000000
ms
F10
Y Y Y Y
60319
0x4F5E
6000000
ms
F10
Y Y Y Y
60321
0x4F60
6000000
ms
F10
Y Y Y Y
60323
0x4F62
6000000
ms
F10
Y Y Y Y
60325
0x4F64
6000000
ms
F10
Y Y Y Y
60327
0x4F66
FlexCurve C Time
10.0xPKP
6000000
ms
F10
Y Y Y Y
60329
0x4F68
FlexCurve C Time
10.5xPKP
6000000
ms
F10
Y Y Y Y
60331
0x4F6A
FlexCurve C Time
11.0xPKP
6000000
ms
F10
Y Y Y Y
60333
0x4F6C
FlexCurve C Time
11.5xPKP
6000000
ms
F10
Y Y Y Y
60335
0x4F6E
FlexCurve C Time
12.0xPKP
6000000
ms
F10
Y Y Y Y
60337
0x4F70
FlexCurve C Time
12.5xPKP
6000000
ms
F10
Y Y Y Y
60339
0x4F72
FlexCurve C Time
13.0xPKP
6000000
ms
F10
Y Y Y Y
60341
0x4F74
FlexCurve C Time
13.5xPKP
6000000
ms
F10
Y Y Y Y
60343
0x4F76
FlexCurve C Time
14.0xPKP
6000000
ms
F10
Y Y Y Y
60345
0x4F78
FlexCurve C Time
14.5xPKP
6000000
ms
F10
Y Y Y Y
60347
0x4F7A
FlexCurve C Time
15.0xPKP
6000000
ms
F10
Y Y Y Y
60349
0x4F7C
FlexCurve C Time
15.5xPKP
6000000
ms
F10
Y Y Y Y
60351
0x4F7E
FlexCurve C Time
16.0xPKP
6000000
ms
F10
Y Y Y Y
60353
0x4F80
FlexCurve C Time
16.5xPKP
6000000
ms
F10
Y Y Y Y
60355
0x4F82
FlexCurve C Time
17.0xPKP
6000000
ms
F10
Y Y Y Y
11-155
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
60357
0x4F84
FlexCurve C Time
17.5xPKP
6000000
ms
F10
Y Y Y Y
60359
0x4F86
FlexCurve C Time
18.0xPKP
6000000
ms
F10
Y Y Y Y
60361
0x4F88
FlexCurve C Time
18.5xPKP
6000000
ms
F10
Y Y Y Y
60363
0x4F8A
FlexCurve C Time
19.0xPKP
6000000
ms
F10
Y Y Y Y
60365
0x4F8C
FlexCurve C Time
19.5xPKP
6000000
ms
F10
Y Y Y Y
60367
0x4F8E
FlexCurve C Time
20.0xPKP
6000000
ms
F10
Y Y Y Y
F60_26
FlexCurve 13
D
Y Y Y Y
FlexCurve 4
60369
0x4F90
FlexCurve Name
65535
60382
0x4F9D
FlexCurve D Time
0.00xPKP
6000000
ms
F10
Y Y Y Y
60384
0x4F9F
FlexCurve D Time
0.05xPKP
6000000
ms
F10
Y Y Y Y
60386
0x4FA1
FlexCurve D Time
0.10xPKP
6000000
ms
F10
Y Y Y Y
60388
0x4FA3
FlexCurve D Time
0.15xPKP
6000000
ms
F10
Y Y Y Y
60390
0x4FA5
FlexCurve D Time
0.20xPKP
6000000
ms
F10
Y Y Y Y
60392
0x4FA7
FlexCurve D Time
0.25xPKP
6000000
ms
F10
Y Y Y Y
60394
0x4FA9
FlexCurve D Time
0.30xPKP
6000000
ms
F10
Y Y Y Y
60396
0x4FAB
FlexCurve D Time
0.35xPKP
6000000
ms
F10
Y Y Y Y
60398
0x4FAD
FlexCurve D Time
0.40xPKP
6000000
ms
F10
Y Y Y Y
60400
0x4FAF
FlexCurve D Time
0.45xPKP
6000000
ms
F10
Y Y Y Y
60402
0x4FB1
FlexCurve D Time
0.48xPKP
6000000
ms
F10
Y Y Y Y
60404
0x4FB3
FlexCurve D Time
0.50xPKP
6000000
ms
F10
Y Y Y Y
60406
0x4FB5
FlexCurve D Time
0.52xPKP
6000000
ms
F10
Y Y Y Y
60408
0x4FB7
FlexCurve D Time
0.54xPKP
6000000
ms
F10
Y Y Y Y
60410
0x4FB9
FlexCurve D Time
0.56xPKP
6000000
ms
F10
Y Y Y Y
60412
0x4FBB
FlexCurve D Time
0.58xPKP
6000000
ms
F10
Y Y Y Y
60414
0x4FBD
FlexCurve D Time
0.60xPKP
6000000
ms
F10
Y Y Y Y
60416
0x4FBF
FlexCurve D Time
0.62xPKP
6000000
ms
F10
Y Y Y Y
60418
0x4FC1
FlexCurve D Time
0.64xPKP
6000000
ms
F10
Y Y Y Y
60420
0x4FC3
FlexCurve D Time
0.66xPKP
6000000
ms
F10
Y Y Y Y
11-156
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
60422
0x4FC5
FlexCurve D Time
0.68xPKP
6000000
ms
F10
Y Y Y Y
60424
0x4FC7
FlexCurve D Time
0.70xPKP
6000000
ms
F10
Y Y Y Y
60426
0x4FC9
FlexCurve D Time
0.72xPKP
6000000
ms
F10
Y Y Y Y
60428
0x4FCB
FlexCurve D Time
0.74xPKP
6000000
ms
F10
Y Y Y Y
60430
6000000
ms
F10
Y Y Y Y
60432
0x4FCF
FlexCurve D Time
0.78xPKP
6000000
ms
F10
Y Y Y Y
60434
0x4FD1
FlexCurve D Time
0.80xPKP
6000000
ms
F10
Y Y Y Y
60436
0x4FD3
FlexCurve D Time
0.82xPKP
6000000
ms
F10
Y Y Y Y
60438
0x4FD5
FlexCurve D Time
0.84xPKP
6000000
ms
F10
Y Y Y Y
60440
0x4FD7
FlexCurve D Time
0.86xPKP
6000000
ms
F10
Y Y Y Y
60442
0x4FD9
FlexCurve D Time
0.88xPKP
6000000
ms
F10
Y Y Y Y
60444
0x4FDB
FlexCurve D Time
0.90xPKP
6000000
ms
F10
Y Y Y Y
60446
6000000
ms
F10
Y Y Y Y
60448
0x4FDF
FlexCurve D Time
0.92xPKP
6000000
ms
F10
Y Y Y Y
60450
0x4FE1
FlexCurve D Time
0.93xPKP
6000000
ms
F10
Y Y Y Y
60452
0x4FE3
FlexCurve D Time
0.94xPKP
6000000
ms
F10
Y Y Y Y
60454
0x4FE5
FlexCurve D Time
0.95xPKP
6000000
ms
F10
Y Y Y Y
60456
0x4FE7
FlexCurve D Time
0.96xPKP
6000000
ms
F10
Y Y Y Y
60458
0x4FE9
FlexCurve D Time
0.97xPKP
6000000
ms
F10
Y Y Y Y
60460
0x4FEB
FlexCurve D Time
0.98xPKP
6000000
ms
F10
Y Y Y Y
60462
0x4FED
FlexCurve D Time
1.03xPKP
6000000
ms
F10
Y Y Y Y
60464
0x4FEF
FlexCurve D Time
1.05xPKP
6000000
ms
F10
Y Y Y Y
60466
0x4FF1
6000000
ms
F10
Y Y Y Y
60468
0x4FF3
6000000
ms
F10
Y Y Y Y
60470
0x4FF5
6000000
ms
F10
Y Y Y Y
60472
0x4FF7
6000000
ms
F10
Y Y Y Y
60474
0x4FF9
6000000
ms
F10
Y Y Y Y
60476
0x4FFB
6000000
ms
F10
Y Y Y Y
60478
0x4FFD
6000000
ms
F10
Y Y Y Y
60480
0x4FFF
6000000
ms
F10
Y Y Y Y
60482
0x5001
6000000
ms
F10
Y Y Y Y
11-157
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
60484
0x5003
6000000
ms
F10
Y Y Y Y
60486
0x5005
6000000
ms
F10
Y Y Y Y
60488
0x5007
6000000
ms
F10
Y Y Y Y
60490
0x5009
6000000
ms
F10
Y Y Y Y
60492
0x500B
6000000
ms
F10
Y Y Y Y
60494
0x500D
6000000
ms
F10
Y Y Y Y
60496
0x500F
6000000
ms
F10
Y Y Y Y
60498
0x5011
6000000
ms
F10
Y Y Y Y
60500
0x5013
6000000
ms
F10
Y Y Y Y
60502
0x5015
6000000
ms
F10
Y Y Y Y
60504
0x5017
6000000
ms
F10
Y Y Y Y
60506
0x5019
6000000
ms
F10
Y Y Y Y
60508
0x501B
6000000
ms
F10
Y Y Y Y
60510
0x501D
6000000
ms
F10
Y Y Y Y
60512
0x501F
6000000
ms
F10
Y Y Y Y
60514
0x5021
6000000
ms
F10
Y Y Y Y
60516
0x5023
6000000
ms
F10
Y Y Y Y
60518
0x5025
6000000
ms
F10
Y Y Y Y
60520
0x5027
6000000
ms
F10
Y Y Y Y
60522
0x5029
6000000
ms
F10
Y Y Y Y
60524
0x502B
6000000
ms
F10
Y Y Y Y
60526
0x502D
6000000
ms
F10
Y Y Y Y
60528
0x502F
6000000
ms
F10
Y Y Y Y
60530
0x5031
6000000
ms
F10
Y Y Y Y
60532
0x5033
6000000
ms
F10
Y Y Y Y
60534
0x5035
6000000
ms
F10
Y Y Y Y
60536
0x5037
6000000
ms
F10
Y Y Y Y
60538
0x5039
6000000
ms
F10
Y Y Y Y
60540
0x503B
6000000
ms
F10
Y Y Y Y
60542
0x503D
6000000
ms
F10
Y Y Y Y
60544
0x503F
6000000
ms
F10
Y Y Y Y
60546
0x5041
6000000
ms
F10
Y Y Y Y
60548
0x5043
6000000
ms
F10
Y Y Y Y
60550
0x5045
6000000
ms
F10
Y Y Y Y
60552
0x5047
6000000
ms
F10
Y Y Y Y
60554
0x5049
6000000
ms
F10
Y Y Y Y
60556
0x504B
6000000
ms
F10
Y Y Y Y
60558
0x504D
6000000
ms
F10
Y Y Y Y
60560
0x504F
6000000
ms
F10
Y Y Y Y
60562
0x5051
6000000
ms
F10
Y Y Y Y
60564
0x5053
6000000
ms
F10
Y Y Y Y
60566
0x5055
6000000
ms
F10
Y Y Y Y
60568
0x5057
6000000
ms
F10
Y Y Y Y
60570
0x5059
6000000
ms
F10
Y Y Y Y
60572
0x505B
6000000
ms
F10
Y Y Y Y
11-158
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
60574
0x505D
6000000
ms
F10
Y Y Y Y
60576
0x505F
6000000
ms
F10
Y Y Y Y
60578
0x5061
6000000
ms
F10
Y Y Y Y
60580
0x5063
FlexCurve D Time
10.0xPKP
6000000
ms
F10
Y Y Y Y
60582
0x5065
FlexCurve D Time
10.5xPKP
6000000
ms
F10
Y Y Y Y
60584
0x5067
FlexCurve D Time
11.0xPKP
6000000
ms
F10
Y Y Y Y
60586
0x5069
FlexCurve D Time
11.5xPKP
6000000
ms
F10
Y Y Y Y
60588
0x506B
FlexCurve D Time
12.0xPKP
6000000
ms
F10
Y Y Y Y
60590
0x506D
FlexCurve D Time
12.5xPKP
6000000
ms
F10
Y Y Y Y
60592
0x506F
FlexCurve D Time
13.0xPKP
6000000
ms
F10
Y Y Y Y
60594
0x5071
FlexCurve D Time
13.5xPKP
6000000
ms
F10
Y Y Y Y
60596
0x5073
FlexCurve D Time
14.0xPKP
6000000
ms
F10
Y Y Y Y
60598
0x5075
FlexCurve D Time
14.5xPKP
6000000
ms
F10
Y Y Y Y
60600
0x5077
FlexCurve D Time
15.0xPKP
6000000
ms
F10
Y Y Y Y
60602
0x5079
FlexCurve D Time
15.5xPKP
6000000
ms
F10
Y Y Y Y
60604
0x507B
FlexCurve D Time
16.0xPKP
6000000
ms
F10
Y Y Y Y
60606
0x507D
FlexCurve D Time
16.5xPKP
6000000
ms
F10
Y Y Y Y
60608
0x507F
FlexCurve D Time
17.0xPKP
6000000
ms
F10
Y Y Y Y
60610
0x5081
FlexCurve D Time
17.5xPKP
6000000
ms
F10
Y Y Y Y
60612
0x5083
FlexCurve D Time
18.0xPKP
6000000
ms
F10
Y Y Y Y
60614
0x5085
FlexCurve D Time
18.5xPKP
6000000
ms
F10
Y Y Y Y
60616
0x5087
FlexCurve D Time
19.0xPKP
6000000
ms
F10
Y Y Y Y
60618
0x5089
FlexCurve D Time
19.5xPKP
6000000
ms
F10
Y Y Y Y
60620
0x508B
FlexCurve D Time
20.0xPKP
6000000
ms
F10
Y Y Y Y
Function
FC100D 0
Y Y Y
Percent Differential
63013
0x59E4
63014
0x59E5
Type
FC356
63015
0x59E6
Pickup
100
x CT
F2
20
Y Y Y
63016
0x59E7
Slope 1
100
F0
25
Y Y Y
63017
0x59E8
Break 1
50
200
x CT
F2
150
Y Y Y
63018
0x59E9
Break 2
200
3000
x CT
F2
400
Y Y Y
63019
0x59EA
Slope 2
100
F0
95
Y Y Y
11-159
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
63020
0x59EB
Pickup Delay
10000
F3
Y Y Y
63021
0x59EC
1000
F3
100
63022
0x59ED
Inrush Inhibit
FC357
63023
0x59EE
10
400
F1
200
63024
0x59EF
FC358
63025
0x59F0
Overexcitation Inhibit
FC359
63026
0x59F1
Overexcitation Level
10
400
F1
100
63027
0x59F2
Block
0xFFFFFFFF
FC142
Y Y Y
63029
0x59F4
Relays
0xFFFFFFFF
FC198H 0
Y Y Y
63031
0x59F6
Instantaneous Diff
Function
FC100
63032
0x59F7
300
3000
F2
1000
63033
0x59F8
0xFFFFFFFF
FC142
63035
0x59FA
0xFFFFFFFF
FC198I
63037
0x59FC
Events
FC126
Y Y Y
63038
0x59FD
Targets
FC101
Y Y Y
FC100D 0
x CT
0x5A18
Function
63067
0x5A1A
Pickup
100
x CT
F2
20
63068
0x5A1B
Slope 1
100
F0
25
63069
0x5A1C
Break 1
50
200
x CT
F2
150
63070
0x5A1D Break 2
200
3000
x CT
F2
400
63071
0x5A1E
Slope 2
100
F0
95
63072
0x5A1F
Pickup Delay
10000
63074
0x5A21
Inrush Inhibit
63075
0x5A22
10
400
63076
0x5A23
63077
0x5A24
Overexcitation Inhibit
F3
FC357
F1
200
FC358
FC359
63078
0x5A25
Overexcitation Level
10
400
F1
100
63079
0x5A26
Block
0xFFFFFFFF
FC142
63081
0x5A28
Relays
0xFFFFFFFF
FC198H 0
63083
0x5A2A
Instantaneous Diff
Function
FC100
63084
0x5A2B
300
3000
F2
1000
63085
0x5A2C
0xFFFFFFFF
FC142
63087
0x5A2E
0xFFFFFFFF
FC198I
63089
0x5A30
Events
FC126
63090
0x5A31
Targets
FC101
Trip Function
FC100D 0
x CT
0x5A52
63125
0x5A54
Overload Curve
16
23
FC161C
23
63126
0x5A55
Curve Effect
FC353
63127
0x5A56
Curve k Factor
100
150
F2
110
63128
0x5A57
1000
F0
45
63129
0x5A58
TD Multiplier
2500
F2
100
63130
0x5A59
TD Multiplier
60000
F2
11-160
min
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
63131
0x5A5A
19
F0
63132
0x5A5B
1000
min
F0
15
63133
0x5A5C
1000
min
F0
30
63134
100
F2
100
63135
0x5A5E
RTD Bias
FC126
63136
0x5A5F
250
F0
40
63137
0x5A60
250
?C
F0
130
63138
0x5A61
250
?C
F0
155
63139
0x5A62
FC126
?C
63140
0x5A63
60
99
63141
0x5A64
VD Voltage Loss
0xFFFFFFFF
63143
0x5A66
150
2000
x FLA
F2
450
63144
0x5A67
10000
F1
200
63145
0x5A68
2000
x FLA
F2
400
63146
0x5A69
2000
x FLA
F2
600
63147
0x5A6A
10000
F1
100
63148
0x5A6B
VD Accel. Intersect @
100% V
150
2000
x FLA
F2
500
63149
0x5A6C
Alarm Function
FC100E
63150
1000
10000
100
F2
7500
63151
0x5A6E
0xFFFFFFFF
FC198C
63153
0x5A70
0xFFFFFFFF
FC198D 0
63155
0x5A72
Block
0xFFFFFFFF
FC142
63157
0x5A74
Events
FC126
63158
0x5A75
Targets
FC101
FC100D 0
F0
80
FC142
Current Unbalance
63183
0x5A8E
Trip Function
63184
0x5A8F
Trip Pickup
40
500
F1
150
63185
0x5A90
18000
F2
100
63186
0x5A91
18000
F2
100
63187
0x5A92
Trip Relays
0xFFFFFFFF
FC198D 0
63189
0x5A94
Alarm Function
FC100E
63190
0x5A95
Alarm Pickup
40
500
F1
150
63191
0x5A96
18000
F2
100
63192
0x5A97
18000
F2
100
63193
0x5A98
Alarm Relays
0xFFFFFFFF
FC198C
63195
0x5A9A
Block
0xFFFFFFFF
FC142
63197
0x5A9C
Events
FC126
63198
0x5A9D Targets
FC101
Mechanical Jam
63223
0x5AB6
Function
FC100
63224
0x5AB7
Pickup
100
1000
x FLA
F2
200
63225
0x5AB8
Pickup Delay
10
18000
F2
100
11-161
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
63226
0x5AB9
18000
F2
100
63227
0x5ABA Relays
0xFFFFFFFF
FC198
63229
0x5ABC Block
0xFFFFFFFF
FC142
63231
0x5ABE
Events
FC126
63232
0x5ABF
Targets
FC101
Y
Y
Dropout Delay
Undercurrent
63263
FC100D 0
63264
0x5ADF
60000
F2
50
63265
0x5AE0
Trip Pickup
10
95
x FLA
F2
70
63266
0x5AE1
18000
F2
100
63267
0x5AE2
18000
F2
100
63268
0x5AE3
Trip Relays
0xFFFFFFFF
FC198D 0
63270
0x5AE5
Alarm Function
FC100E
63271
0x5AE6
Alarm Pickup
10
95
x FLA
F2
70
63272
0x5AE7
18000
F2
100
63273
0x5AE8
18000
F2
100
63274
0x5AE9
Alarm Relays
0xFFFFFFFF
FC198C
63276
0x5AEB
Block
0xFFFFFFFF
FC142
63278
0x5AED Events
FC126
63279
0x5AEE
FC101
FC102C
Targets
Generator Unbalance
63290
0x5AF9
Signal Input
63291
0x5AFA
Trip Function
63292
0x5AFB
Trip Pickup
10000
63293
0x5AFC
Constant K
10000
%FLA
FC100D 0
F2
800
F2
100
63294
0x5AFD
Maximum Time
1000
F0
600
63295
0x5AFE
Reset Time
100000
F12
22700
63297
0x5B00
0xFFFFFFFF
FC198
63299
0x5B02
Alarm Function
FC100E
63300
0x5B03
Alarm Pickup
10000
%FLA
F2
300
63301
0x5B04
Alarm Delay
60000
F2
50
63302
0x5B05
0xFFFFFFFF
FC198
63304
0x5B07
Block
0xFFFFFFFF
FC142
63306
0x5B09
Events
FC126
63307
0x5B0A
Targets
FC101
Inadvertent Energization
63320
0x5B17
Function
FC100
63321
0x5B18
Arming Mode
FC382
63322
0x5B19
O/C Pickup
3000
x CT
F2
30
63323
0x5B1A
U/V Pickup
150
x VT
F2
50
63324
0x5B1B
Output Relay
0xFFFFFFFF
FC198
63326
0x5B1D Block
0xFFFFFFFF
FC142
63328
0x5B1F
Events
FC126
63329
0x5B20
Targets
FC101
Loss of Excitation
11-162
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
63340
0x5B2B
Signal Input
FC391
63341
0x5B2C
Circle 1 Function
FC100
63342
FC100
63343
0x5B2E
Circle 1 Diameter
3000
ohms
F1
250
63344
0x5B2F
Circle 2 Diameter
3000
ohms
F1
350
63345
0x5B30
Circle 1 Offset
3000
ohms
F1
25
63346
0x5B31
Circle 2 Offset
3000
ohms
F1
25
63347
0x5B32
60000
F2
30
63348
0x5B33
60000
F2
100
63349
0x5B34
Circle 1 UV Supervision
FC126
63350
0x5B35
Circle 2 UV Supervision
FC126
63351
0x5B36
0xFFFFFFFF
FC198
63353
0x5B38
0xFFFFFFFF
FC198
63355
0x5B3A
UV Supervision
150
F2
70
63356
0x5B3B
Block
0xFFFFFFFF
FC142
63358
0x5B3D Events
FC126
63359
0x5B3E
FC101
FC100D 0
F2
Targets
x VT
0x5B49
Trip Function
63371
0x5B4A
Trip Pickup
10
2000
V
s
63372
0x5B4B
60000
63373
0x5B4C
Trip Relay
0xFFFFFFFF
63375
0x5B4E
Alarm Function
63376
0x5B4F
Alarm Pickup
10
2000
63377
0x5B50
60000
100
F2
100
FC198
FC100E
F2
50
F2
100
FC198
63378
0x5B51
Alarm Relay
0xFFFFFFFF
63380
0x5B53
1250
x Rated F3
200
63381
0x5B54
1250
x Rated F3
200
x VT
63382
0x5B55
150
F2
50
63383
0x5B56
Block
0xFFFFFFFF
FC142
63385
0x5B58
Events
FC126
63386
0x5B59
Targets
FC101
0x5B67
Trip Function
FC100D 0
63401
0x5B68
Trip Pickup
900
F3
100
63402
0x5B69
60000
F2
50
F1
50
63403
0x5B6A
Trip Supv
300
63404
0x5B6B
Trip Relay
0xFFFFFFFF
FC198D 0
63406
FC100E
63407
0x5B6E
Alarm Pickup
900
F3
150
63408
0x5B6F
60000
F2
100
63409
0x5B70
Alarm Supv
300
F1
50
63410
0x5B71
Alarm Relay
0xFFFFFFFF
FC198C
63412
0x5B73
Block
0xFFFFFFFF
FC142
63414
0x5B75
Events
FC126
11-163
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
63415
Targets
FC101
0x5B76
0x5B85
Function
FC100
63431
0x5B86
Signal Input
FC102A
63432
0x5B87
Pickup
100
x CT
F2
63433
0x5B88
Pickup Delay
60000
F2
63434
0x5B89
Output Relay
0xFFFFFFFF
FC198
63436
0x5B8B
Block
0xFFFFFFFF
FC142
63438
0x5B8D Events
FC126
63439
0x5B8E
FC101
FC100A
Y Y
Targets
Overload Alarm
63513
0x5BD8 Function
63514
0x5BD9 Pickup
50
300
x FLA
F2
70
Y Y
63515
18000
F2
100
Y Y
63516
18000
F2
100
Y Y
63517
0x5BDC Block
0xFFFFFFFF
FC142
Y Y
63519
0x5BDE Relays
0xFFFFFFFF
FC198
Y Y
63521
0x5BE0
Events
FC126
Y Y
63522
0x5BE1
Targets
FC101
Y Y
FC100
F2
600
Short Circuit
63666
0x5C71
Function
63667
0x5C72
Pickup
100
3000
63668
0x5C73
Pickup Delay
18000
F2
100
63669
0x5C74
Dropout Delay
18000
F2
100
63670
0x5C75
Relays
0xFFFFFFFF
FC198
63672
0x5C77
Block
0xFFFFFFFF
FC142
63674
0x5C79
Events
FC126
63675
0x5C7A
Targets
FC101
Trip Function
FC100D 0
x CT
Ground Fault
63703
0x5C96
63704
0x5C97
Ground CT Type
FC104A
63705
0x5C98
Trip Pickup
1000
x CT
F2
10
63706
0x5C99
Trip Pickup
50
1500
F2
1000
63707
0x5C9A
18000
F2
100
63708
0x5C9B
18000
F2
100
63709
0x5C9C
18000
F2
100
63710
0xFFFFFFFF
FC198D 0
63712
0x5C9F
Alarm Function
FC100E
63713
0x5CA0
Alarm Pickup
1000
x CT
F2
20
63714
0x5CA1
Alarm Pickup
50
1500
F2
500
63715
0x5CA2
18000
F2
100
63716
0x5CA3
18000
F2
100
63717
0x5CA4
Alarm Relays
0xFFFFFFFF
FC198C
63719
0x5CA6
Block
0xFFFFFFFF
FC142
63721
0x5CA8
Events
FC126
11-164
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
63722
Targets
FC101
Name
0x5CA9
Acceleration Time
63753
0x5CC8
65535
F60_26
Spd2 Accel 13
63766
0x5CD5 Function
FC100
63767
0x5CD6 Current
100
1000
x FLA
F2
600
63768
0x5CD7 Time
50
18000
F2
1000
63769
0x5CD8 Mode
FC352
63771
0x5CDA Block
0xFFFFFFFF
FC142
63773
0x5CDC Relays
0xFFFFFFFF
FC198
63775
0x5CDE Events
FC126
63776
0x5CDF Targets
FC101
Underpower
63803
0x5CFA
Trip Function
FC100D 0
63804
0x5CFB
60000
F2
50
63805
0x5CFC
Trip Pickup
25000
kW
F0
63806
18000
F2
100
63807
0x5CFE
18000
F2
100
63808
0x5CFF
Trip Relays
0xFFFFFFFF
FC198D 0
63810
0x5D01
Alarm Function
FC100E
63811
0x5D02
Alarm Pickup
25000
kW
F0
63812
0x5D03
18000
F2
100
63813
0x5D04
18000
F2
100
63814
0x5D05
Alarm Relays
0xFFFFFFFF
FC198C
63816
0x5D07
Block
0xFFFFFFFF
FC142
63818
0x5D09
Events
FC126
63819
0x5D0A Targets
FC101
FC100
Transformer Overload
63850
0x5D29
Function
63851
0x5D2A Pickup
50
300
F0
208
63852
60000
F0
10
63853
0xFFFFFFFF
FC142
63855
0x5D2E
Block
0xFFFFFFFF
FC142
63857
0x5D30
Output Relays
0xFFFFFFFF
FC198
63859
0x5D32
Events
FC126
63860
0x5D33
Targets
FC101
0x5D47
Overload Curve
16
23
FC161C
23
63881
0x5D48
TD Multiplier
100
2500
F2
100
63882
0x5D49
TD Multiplier
60000
F2
63883
FC126
63884
60
99
F0
80
63885
0xFFFFFFFF
FC142
63887
0x5D4E
150
2000
x FLA
F2
450
63888
0x5D4F
10000
F1
200
63889
0x5D50
2000
x FLA
F2
400
11-165
Modbus Hex
Description
Address Address
63890
0x5D51
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
2000
F2
600
x FLA
63891
0x5D52
10000
F1
100
63892
0x5D53
VD Accel. Intersect @
100% V
150
2000
x FLA
F2
500
Speed2 Acceleration
63910
0x5D65
Current
100
1000
x FLA
F2
600
63911
0x5D66
Time
100
18000
F2
1000
63912
0x5D67
Mode
FC352
63914
0x5D69
50
18000
F2
1000
63915
0x5D6A Block
0xFFFFFFFF
FC142
60000
F2
50
Y
Y
Speed2 Undercurrent
63930
0x5D79
63931
10
95
x FLA
F2
70
63932
18000
F2
100
63933
18000
F2
100
63934
10
95
x FLA
F2
70
63935
0x5D7E
18000
F2
100
63936
0x5D7F
18000
F2
100
63937
0x5D80
Block
0xFFFFFFFF
FC142
Phase TOC 1
63973
0x5DA4 Function
FC100
63974
FC102A
Y Y
63975
0x5DA6 Input
FC256
Y Y Y Y
63976
0x5DA7 Pickup
50
30000
F13
1000
Y Y Y Y
63978
0x5DA9 Curve
21
FC161
Y Y Y Y
63979
0x5DAA TDM
60000
F2
100
Y Y Y Y
63980
0x5DAB Reset
FC166
Y Y Y Y
63981
FC126
Y Y Y Y
x CT
p.u.
Y Y Y Y
63982
F1
63983
0x5DAE
Direction
FC164
Y Y Y Y
63984
0x5DAF
Relays
0xFFFFFFFF
FC198
Y Y Y Y
63986
0x5DB1 Block
0xFFFFFFFF
FC142
Y Y Y Y
63988
0x5DB3 Events
FC126
Y Y Y Y
63989
0x5DB4 Targets
FC101
Y Y Y Y
FC100
Y Y
Phase TOC 2
64013
0x5DCC Function
64014
FC102A
64015
0x5DCE Input
FC256
Y Y
64016
0x5DCF Pickup
50
30000
F13
1000
Y Y
64018
0x5DD1 Curve
21
FC161
Y Y
64019
0x5DD2 TDM
60000
F2
100
Y Y
64020
0x5DD3 Reset
FC166
Y Y
64021
FC126
Y Y
64022
F1
x CT
p.u.
Y Y
64023
0x5DD6 Direction
FC164
Y Y
64024
0x5DD7 Relays
0xFFFFFFFF
FC198
Y Y
11-166
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
64026
0x5DD9 Block
0xFFFFFFFF
FC142
Y Y
64028
0x5DDB Events
FC126
Y Y
64029
0x5DDC Targets
FC101
Y Y
Phase TOC 3
64053
0x5DF4
Function
FC100
64054
0x5DF5
Signal Input
FC102A
64055
0x5DF6
Input
FC256
64056
0x5DF7
Pickup
50
30000
F13
1000
64058
0x5DF9
Curve
21
FC161
64059
0x5DFA
TDM
60000
F2
100
64060
0x5DFB
Reset
FC166
64061
0x5DFC
Voltage Restraint
FC126
x CT
64062
F1
64063
0x5DFE
Direction
p.u.
FC164
Y
Y
64064
0x5DFF
Relays
0xFFFFFFFF
FC198
64066
0x5E01
Block
0xFFFFFFFF
FC142
64068
0x5E03
Events
FC126
64069
0x5E04
Targets
FC101
Function
FC100
Y Y Y Y
Phase IOC 1
64103
0x5E26
64104
0x5E27
Signal Input
FC102A
Y Y
64105
0x5E28
Input
FC256
Y Y Y Y
64106
0x5E29
Pickup
50
30000
64108
0x5E2B
Direction
64109
0x5E2C
Pickup Delay
6000000
64111
0x5E2E
Dropout Delay
6000000
F13
Y Y Y Y
64113
0x5E30
Relays
0xFFFFFFFF
FC198
Y Y Y Y
64115
0x5E32
Block
0xFFFFFFFF
FC142
Y Y Y Y
64117
0x5E34
Events
FC126
Y Y Y Y
64118
0x5E35
Targets
FC101
Y Y Y Y
x CT
F13
1000
Y Y Y Y
FC164
Y Y Y Y
F13
Y Y Y Y
Phase IOC 2
64142
0x5E4D
Function
FC100
Y Y Y Y
64143
0x5E4E
Signal Input
FC102A
Y Y
64144
0x5E4F
Input
FC256
Y Y Y Y
64145
0x5E50
Pickup
50
30000
F13
1000
Y Y Y Y
64147
0x5E52
Direction
FC164
Y Y Y Y
64148
0x5E53
Pickup Delay
6000000
F13
Y Y Y Y
64150
0x5E55
Dropout Delay
6000000
F13
Y Y Y Y
64152
0x5E57
Relays
0xFFFFFFFF
FC198
Y Y Y Y
64154
0x5E59
Block
0xFFFFFFFF
FC142
Y Y Y Y
64156
0x5E5B
Events
FC126
Y Y Y Y
64157
0x5E5C
Targets
FC101
Y Y Y Y
x CT
Phase IOC 3
64181
0x5E74
Function
FC100
Y Y
64182
0x5E75
Signal Input
FC102A
Y Y
11-167
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
64183
0x5E76
Input
FC256
64184
0x5E77
Pickup
50
30000
64186
0x5E79
Direction
64187
0x5E7A
Pickup Delay
6000000
s
s
x CT
Y Y
F13
1000
Y Y
FC164
Y Y
F13
Y Y
64189
0x5E7C
Dropout Delay
6000000
F13
Y Y
64191
0x5E7E
Relays
0xFFFFFFFF
FC198
Y Y
64193
0x5E80
Block
0xFFFFFFFF
FC142
Y Y
64195
0x5E82
Events
FC126
Y Y
64196
0x5E83
Targets
FC101
Y Y
Phase IOC 4
64220
0x5E9B
Function
FC100
Y Y
64221
0x5E9C
Signal Input
FC102A
Y Y
FC256
Y Y
F13
1000
Y Y
Y Y
64222
0x5E9D
Input
64223
0x5E9E
Pickup
50
30000
x CT
64225
0x5EA0
Direction
FC164
64226
0x5EA1
Pickup Delay
6000000
F13
Y Y
64228
0x5EA3
Dropout Delay
6000000
F13
Y Y
64230
0x5EA5
Relays
0xFFFFFFFF
FC198
Y Y
64232
0x5EA7
Block
0xFFFFFFFF
FC142
Y Y
64234
0x5EA9
Events
FC126
Y Y
64235
0x5EAA
Targets
FC101
Y Y
Y Y
Phase IOC 5
64259
0x5EC2
Function
FC100
64260
0x5EC3
Signal Input
FC102A
Y Y
64261
0x5EC4
Input
FC256
Y Y
64262
0x5EC5
Pickup
50
30000
64264
0x5EC7
Direction
64265
0x5EC8
Pickup Delay
6000000
s
s
x CT
F13
1000
Y Y
FC164
Y Y
F13
Y Y
64267
0x5ECA
Dropout Delay
6000000
F13
Y Y
64269
0x5ECC
Relays
0xFFFFFFFF
FC198
Y Y
64271
0x5ECE
Block
0xFFFFFFFF
FC142
Y Y
64273
0x5ED0
Events
FC126
Y Y
64274
0x5ED1
Targets
FC101
Y Y
Phase IOC 6
64298
0x5EE9
Function
FC100
Y Y
64299
0x5EEA
Signal Input
FC102A
Y Y
64300
0x5EEB
Input
64301
0x5EEC
Pickup
50
30000
x CT
FC256
Y Y
F13
1000
Y Y
Y Y
64303
0x5EEE
Direction
FC164
64304
0x5EEF
Pickup Delay
6000000
F13
Y Y
64306
0x5EF1
Dropout Delay
6000000
F13
Y Y
64308
0x5EF3
Relays
0xFFFFFFFF
FC198
Y Y
64310
0x5EF5
Block
0xFFFFFFFF
FC142
Y Y
64312
0x5EF7
Events
FC126
Y Y
64313
0x5EF8
Targets
FC101
Y Y
11-168
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
Phase IOC 7
64337
0x5F10
Function
FC100
64338
0x5F11
Signal Input
FC102A
64339
0x5F12
Input
FC256
64340
0x5F13
Pickup
50
30000
64342
0x5F15
Direction
x CT
F13
1000
FC164
64343
0x5F16
Pickup Delay
6000000
F13
64345
0x5F18
Dropout Delay
6000000
F13
64347
0x5F1A
Relays
0xFFFFFFFF
FC198
64349
0x5F1C
Block
0xFFFFFFFF
FC142
64351
0x5F1E
Events
FC126
64352
0x5F1F
Targets
FC101
Function
FC100
Phase IOC 8
64376
0x5F37
64377
0x5F38
Signal Input
FC102A
64378
0x5F39
Input
FC256
64379
0x5F3A
Pickup
50
30000
F13
1000
Y
Y
x CT
64381
0x5F3C
Direction
FC164
64382
0x5F3D
Pickup Delay
6000000
F13
64384
0x5F3F
Dropout Delay
6000000
F13
64386
0x5F41
Relays
0xFFFFFFFF
FC198
64388
0x5F43
Block
0xFFFFFFFF
FC142
64390
0x5F45
Events
FC126
64391
0x5F46
Targets
FC101
Y
Y Y Y Y
Phase DirOC
64433
0x5F70
Function
FC126
64434
0x5F71
Signal Input
FC102D 1
Y Y
64435
0x5F72
ECA
359
F0
Y Y Y Y
64436
0x5F73
Polarizing V Threshold
50
3000
x VT
F3
700
Y Y Y Y
64437
0x5F74
FC126B
Y Y Y Y
64438
0x5F75
Block
0xFFFFFFFF
FC142
Y Y Y Y
64440
0x5F77
Events
FC126
Y Y Y Y
64441
0x5F78
Targets
FC101
Y Y Y Y
30
Neutral TOC 1
64473
0x5F98
Function
FC100
Y Y Y Y
64474
0x5F99
Signal Input
FC102A
Y Y
64475
0x5F9A
Input
FC256
Y Y Y Y
64476
0x5F9B
Pickup
50
30000
F13
1000
Y Y Y Y
Y Y Y Y
x CT
64478
0x5F9D
Curve
21
FC161
64479
0x5F9E
TDM
60000
F2
100
Y Y Y Y
64480
0x5F9F
Reset
FC265
Y Y Y Y
64481
0x5FA0
Direction
FC164
Y Y Y Y
64482
0x5FA1
Relays
0xFFFFFFFF
FC198
Y Y Y Y
64484
0x5FA3
Block
0xFFFFFFFF
FC142
Y Y Y Y
64486
0x5FA5
Events
FC126
Y Y Y Y
11-169
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
64487
Targets
FC101
Y Y Y Y
Y
0x5FA6
Neutral TOC 2
64511
0x5FBE
Function
FC100
64512
0x5FBF
Signal Input
FC102A
Y Y
FC256
Y Y
F13
1000
Y Y
Y Y
64513
0x5FC0
Input
64514
0x5FC1
Pickup
50
30000
64516
0x5FC3
Curve
21
FC161
Y Y
64517
0x5FC4
TDM
60000
F2
100
Y Y
64518
0x5FC5
Reset
FC265
Y Y
x CT
64519
0x5FC6
Direction
FC164
Y Y
64520
0x5FC7
Relays
0xFFFFFFFF
FC198
Y Y
64522
0x5FC9
Block
0xFFFFFFFF
FC142
Y Y
64524
0x5FCB
Events
FC126
Y Y
64525
0x5FCC
Targets
FC101
Y Y
Neutral TOC 3
64549
0x5FE4
Function
FC100
64550
0x5FE5
Signal Input
FC102A
FC256
F13
1000
64551
0x5FE6
Input
64552
0x5FE7
Pickup
50
30000
64554
0x5FE9
Curve
21
FC161
64555
0x5FEA
TDM
60000
F2
100
64556
0x5FEB
Reset
FC265
x CT
64557
0x5FEC
Direction
FC164
64558
0x5FED
Relays
0xFFFFFFFF
FC198
64560
0x5FEF
Block
0xFFFFFFFF
FC142
64562
0x5FF1
Events
FC126
64563
0x5FF2
Targets
FC101
Neutral IOC 1
64603
0x601A
Function
FC100
Y Y Y Y
64604
0x601B
Signal Input
FC102A
Y Y
64606
0x601D
Pickup
50
30000
64608
0x601F
Direction
64609
0x6020
Pickup Delay
6000000
s
s
x CT
F13
1000
Y Y Y Y
FC164
Y Y Y Y
F13
Y Y Y Y
64611
0x6022
Dropout Delay
6000000
F13
Y Y Y Y
64613
0x6024
Relays
0xFFFFFFFF
FC198
Y Y Y Y
64615
0x6026
Block
0xFFFFFFFF
FC142
Y Y Y Y
64617
0x6028
Events
FC126
Y Y Y Y
64618
0x6029
Targets
FC101
Y Y Y Y
Neutral IOC 2
64642
0x6041
Function
FC100
Y Y Y Y
64643
0x6042
Signal Input
FC102A
Y Y
64645
0x6044
Pickup
50
30000
64647
0x6046
Direction
64648
0x6047
Pickup Delay
6000000
64650
0x6049
Dropout Delay
6000000
11-170
x CT
F13
1000
Y Y Y Y
FC164
Y Y Y Y
F13
Y Y Y Y
F13
Y Y Y Y
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
64652
0x604B
0xFFFFFFFF
FC198
Y Y Y Y
64654
0x604D
Block
0xFFFFFFFF
FC142
Y Y Y Y
64656
0x604F
Events
FC126
Y Y Y Y
64657
0x6050
Targets
FC101
Y Y Y Y
Function
FC100
Y Y
FC102A
Y Y
F13
1000
Y Y
FC164
Y Y
Relays
Neutral IOC 3
64681
0x6068
64682
0x6069
Signal Input
64684
0x606B
Pickup
50
30000
64686
0x606D
Direction
x CT
64687
0x606E
Pickup Delay
6000000
F13
Y Y
64689
0x6070
Dropout Delay
6000000
F13
Y Y
64691
0x6072
Relays
0xFFFFFFFF
FC198
Y Y
64693
0x6074
Block
0xFFFFFFFF
FC142
Y Y
64695
0x6076
Events
FC126
Y Y
64696
0x6077
Targets
FC101
Y Y
Function
FC100
FC102A
F13
1000
FC164
Neutral IOC 4
64720
0x608F
64721
0x6090
Signal Input
64723
0x6092
Pickup
50
30000
64725
0x6094
Direction
x CT
64726
0x6095
Pickup Delay
6000000
F13
64728
0x6097
Dropout Delay
6000000
F13
64730
0x6099
Relays
0xFFFFFFFF
FC198
64732
0x609B
Block
0xFFFFFFFF
FC142
64734
0x609D
Events
FC126
64735
0x609E
Targets
FC101
Function
FC100
Neutral IOC 5
64759
0x60B6
64760
0x60B7
Signal Input
64762
0x60B9
Pickup
50
30000
x CT
FC102A
F13
1000
64764
0x60BB
Direction
FC164
64765
0x60BC
Pickup Delay
6000000
F13
64767
0x60BE
Dropout Delay
6000000
F13
64769
0x60C0
Relays
0xFFFFFFFF
FC198
64771
0x60C2
Block
0xFFFFFFFF
FC142
64773
0x60C4
Events
FC126
64774
0x60C5
Targets
FC101
Y
Y
Neutral IOC 6
64798
0x60DD Function
FC100
64799
0x60DE
Signal Input
FC102A
64801
0x60E0
Pickup
50
30000
F13
1000
x CT
64803
0x60E2
Direction
FC164
64804
0x60E3
Pickup Delay
6000000
F13
64806
0x60E5
Dropout Delay
6000000
F13
64808
0x60E7
Relays
0xFFFFFFFF
FC198
11-171
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
64810
0xFFFFFFFF
FC142
0x60E9
Block
64812
0x60EB
Events
FC126
64813
0x60EC
Targets
FC101
Neutral Directional OC
64853
0x6114
Function
FC126
Y Y Y Y
64854
0x6115
Signal Input
FC102D 1
Y Y
64855
0x6116
Polarizing Mode
FC156
Y Y Y Y
64856
0x6117
Polarizing Voltage
FC272
Y Y Y Y
64857
0x6118
Pos-Seq Restraint
500
F3
63
Y Y Y Y
64859
0x611A
Forward ECA
-90
90
F20
75
Y Y Y Y
64860
0x611B
40
90
F0
90
Y Y Y Y
64861
0x611C
Forward Pickup
50
30000
x CT
F3
50
Y Y Y Y
64862
0x611D
40
90
F0
90
Y Y Y Y
64863
0x611E
Reverse Pickup
50
30000
x CT
F3
50
Y Y Y Y
64864
0x611F
Block
0xFFFFFFFF
FC142
Y Y Y Y
64866
0x6121
Events
FC126
Y Y Y Y
64867
0x6122
Targets
FC101
Y Y Y Y
Ground TOC 1
64893
0x613C
Function
FC100
Y Y Y Y
64894
0x613D
Signal Input
FC102A
Y Y
FC256
Y Y Y Y
F13
1000
Y Y Y Y
Y Y Y Y
64895
0x613E
Input
64896
0x613F
Pickup
50
30000
64898
0x6141
Curve
21
FC161
64899
0x6142
TDM
60000
F2
100
Y Y Y Y
64900
0x6143
Reset
FC265
Y Y Y Y
x CT
64901
0x6144
Direction
FC164
64902
0x6145
Relays
0xFFFFFFFF
FC198
Y Y Y Y
Y Y
64904
0x6147
Block
0xFFFFFFFF
FC142
Y Y Y Y
64906
0x6149
Events
FC126
Y Y Y Y
64907
0x614A
Targets
FC101
Y Y Y Y
Ground TOC 2
64931
0x6162
Function
FC100
Y Y
64932
0x6163
Signal Input
FC102A
Y Y
FC256
Y Y
F13
1000
Y Y
Y Y
64933
0x6164
Input
64934
0x6165
Pickup
50
30000
64936
0x6167
Curve
21
FC161
64937
0x6168
TDM
60000
F2
100
Y Y
64938
0x6169
Reset
FC265
Y Y
x CT
64939
0x616A
Direction
FC164
Y Y
64940
0x616B
Relays
0xFFFFFFFF
FC198
Y Y
64942
0x616D
Block
0xFFFFFFFF
FC142
Y Y
64944
0x616F
Events
FC126
Y Y
64945
0x6170
Targets
FC101
Y Y
Function
FC100
Ground TOC 3
64969
11-172
0x6188
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
64970
0x6189
Signal Input
FC102A
64971
0x618A
Input
FC256
64972
0x618B
Pickup
50
30000
F13
1000
64974
0x618D
Curve
21
FC161
64975
0x618E
TDM
60000
F2
100
64976
0x618F
Reset
FC265
x CT
64977
0x6190
Direction
FC164
64978
0x6191
Relays
0xFFFFFFFF
FC198
64980
0x6193
Block
0xFFFFFFFF
FC142
64982
0x6195
Events
FC126
64983
0x6196
Targets
FC101
Ground IOC 1
65023
0x61BE
Function
FC100
Y Y Y Y
65024
0x61BF
Signal Input
FC102A
Y Y
65026
0x61C1
Pickup
50
30000
Y Y Y Y
65028
0x61C3
Direction
65029
0x61C4
Pickup Delay
6000000
65031
0x61C6
Dropout Delay
6000000
F13
Y Y Y Y
65033
0x61C8
Relays
0xFFFFFFFF
FC198
Y Y Y Y
65035
0x61CA
Block
0xFFFFFFFF
FC142
Y Y Y Y
65037
0x61CC
Events
65038
0x61CD Targets
x CT
F13
1000
FC164
F13
Y Y Y Y
Y Y
FC126
Y Y Y Y
FC101
Y Y Y Y
Ground IOC 2
65062
0x61E5
Function
FC100
Y Y
65063
0x61E6
Signal Input
FC102A
Y Y
65065
0x61E8
Pickup
50
30000
Y Y
65067
0x61EA
Direction
65068
0x61EB
Pickup Delay
6000000
65070
0x61ED
Dropout Delay
6000000
F13
Y Y
65072
0x61EF
Relays
0xFFFFFFFF
FC198
Y Y
65074
0x61F1
Block
0xFFFFFFFF
FC142
Y Y
65076
0x61F3
Events
FC126
Y Y
65077
0x61F4
Targets
FC101
Y Y
x CT
F13
1000
FC164
Y Y
F13
Y Y
Ground IOC 3
65101
0x620C
Function
FC100
65102
0x620D
Signal Input
FC102A
65104
0x620F
Pickup
50
30000
65106
0x6211
Direction
x CT
F13
1000
FC164
65107
0x6212
Pickup Delay
6000000
F13
65109
0x6214
Dropout Delay
6000000
F13
65111
0x6216
Relays
0xFFFFFFFF
FC198
65113
0x6218
Block
0xFFFFFFFF
FC142
65115
0x621A
Events
FC126
65116
0x621B
Targets
FC101
Ground IOC 4
11-173
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
65140
Function
FC100
0x6233
65141
0x6234
Signal Input
65143
0x6236
Pickup
50
30000
65145
0x6238
Direction
65146
0x6239
Pickup Delay
6000000
F13
65148
0x623B
Dropout Delay
6000000
F13
65150
0x623D
Relays
0xFFFFFFFF
FC198
65152
0x623F
Block
0xFFFFFFFF
FC142
65154
0x6241
Events
FC126
65155
0x6242
Targets
FC101
Function
FC100
x CT
FC102A
F13
1000
FC164
Ground IOC 5
65179
0x625A
65180
0x625B
Signal Input
65182
0x625D
Pickup
50
30000
x CT
FC102A
F13
1000
Y
Y
65184
0x625F
Direction
FC164
65185
0x6260
Pickup Delay
6000000
F13
65187
0x6262
Dropout Delay
6000000
F13
65189
0x6264
Relays
0xFFFFFFFF
FC198
65191
0x6266
Block
0xFFFFFFFF
FC142
65193
0x6268
Events
FC126
65194
0x6269
Targets
FC101
Ground IOC 6
65218
0x6281
Function
FC100
65219
0x6282
Signal Input
FC102A
65221
0x6284
Pickup
50
30000
F13
1000
Y
Y
x CT
65223
0x6286
Direction
FC164
65224
0x6287
Pickup Delay
6000000
F13
65226
0x6289
Dropout Delay
6000000
F13
65228
0x628B
Relays
0xFFFFFFFF
FC198
65230
0x628D
Block
0xFFFFFFFF
FC142
65232
0x628F
Events
FC126
65233
0x6290
Targets
FC101
Ground Directional OC
65273
0x62B8
Function
FC126
65274
0x62B9
Signal Input
FC102A
Y Y
65275
0x62BA
Polarizing Mode
FC156
65276
0x62BB
Polarizing Voltage
65278
-90
90
Y Y
FC272
Y Y
F20
75
Y Y
65279
0x62BE
40
90
F0
90
Y Y
65280
0x62BF
Forward Pickup
50
30000
x CT
F3
50
Y Y
65281
0x62C0
40
90
F0
90
Y Y
x CT
65282
0x62C1
Reverse Pickup
50
30000
F3
50
Y Y
65283
0x62C2
Block
0xFFFFFFFF
FC142
Y Y
65285
0x62C4
Events
FC126
Y Y
65286
0x62C5
Targets
FC101
Y Y
11-174
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
0x62E0
Function
FC100
65315
0x62E2
Input
FC256
65316
0x62E3
Pickup
3000
F13
1000
x CT
65318
0x62E5
Curve
21
FC161
65319
0x62E6
TDM
60000
F2
100
65320
0x62E7
Reset
FC265
65321
0x62E8
Direction
FC164
65322
0x62E9
Relays
0xFFFFFFFF
FC198
65324
0x62EB
Block
0xFFFFFFFF
FC142
65326
0x62ED
Events
FC126
65327
0x62EE
Targets
FC101
FC100
0x633A
Function
65406
0x633D
Pickup
3000
65408
0x633F
Direction
65409
0x6340
Pickup Delay
6000000
s
s
x CT
F13
1000
FC164
F13
65411
0x6342
Dropout Delay
6000000
F13
65413
0x6344
Relays
0xFFFFFFFF
FC198
65415
0x6346
Block
0xFFFFFFFF
FC142
65417
0x6348
Events
FC126
65418
0x6349
Targets
FC101
0x6387
Function
FC126
65482
0x6389
Polarizing Mode
FC156
Y
Y
65483
0x638A
Polarizing Voltage
FC272
65484
0x638B
Forward ECA
-90
90
F20
75
65485
0x638C
40
90
F0
90
65486
0x638D
Forward Pickup
3000
x CT
F3
50
65487
0x638E
40
90
F0
90
x CT
65488
0x638F
Reverse Pickup
3000
F3
50
65489
0x6390
Block
0xFFFFFFFF
FC142
65491
0x6392
Events
FC126
65492
0x6393
Targets
FC101
Function
FC100
Y Y
Y Y
0x63B2
65524
0x63B3
Signal Input
65525
0x63B4
Pickup
50
30000
x CT
FC102A
F3
300
65526
0x63B5
Slope
100
F0
50
Y Y
65527
0x63B6
Pickup Delay
6000000
F13
100
Y Y
65529
0x63B8
FC126
Y Y
65530
0x63B9
50
30000
F3
300
Y Y
65531
0x63BA
Relays
0xFFFFFFFF
FC198
Y Y
65533
0x63BC
Block
0xFFFFFFFF
FC142
Y Y
65535
0x63BE
Events
FC126
Y Y
x CT
11-175
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
65536
FC101
0x63BF
Targets
Y Y
0x63D7
Function
FC100
65561
0x63D8
Signal Input
FC102A
65562
0x63D9
Pickup
50
30000
x CT
F3
300
65563
0x63DA Slope
100
F0
50
65564
6000000
65566
65567
0x63DE
50
30000
65568
0x63DF
Relays
0xFFFFFFFF
65570
0x63E1
Block
0xFFFFFFFF
65572
0x63E3
Events
65573
0x63E4
Targets
F13
100
FC126
F3
300
FC198
FC142
FC126
FC101
Y
Y
x CT
0x63FC
Function
FC100
65598
0x63FD
Signal Input
FC102A
65599
0x63FE
Pickup
50
30000
x CT
F3
300
Y
Y
65600
0x63FF
Slope
100
F0
50
65601
0x6400
Pickup Delay
6000000
F13
100
65603
0x6402
FC126
65604
0x6403
50
30000
F3
300
65605
0x6404
Relays
0xFFFFFFFF
x CT
FC198
65607
0x6406
Block
0xFFFFFFFF
FC142
65609
0x6408
Events
FC126
65610
0x6409
Targets
FC101
0x6434
Function
FC100
65654
0x6435
Signal Input
FC102A
x CT
Y
Y
65655
0x6436
Pickup
50
30000
F13
1000
65657
0x6438
Curve
21
FC161
65658
0x6439
TDM
60000
F2
100
65659
0x643A
Reset
FC265
65660
0x643B
Direction
FC164
65661
0x643C
Relays
0xFFFFFFFF
FC198
65663
0x643E
Block
0xFFFFFFFF
FC142
65665
0x6440
Events
FC126
65666
0x6441
Targets
FC101
0x6459
Function
FC100
65691
0x645A
Signal Input
FC102A
65692
0x645B
Pickup
50
30000
F13
1000
65694
0x645D
Curve
21
FC161
65695
0x645E
TDM
60000
F2
100
65696
0x645F
Reset
FC265
65698
0x6461
Relays
0xFFFFFFFF
FC198
11-176
x CT
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
65700
0x6463
Block
0xFFFFFFFF
FC142
65702
0x6465
Events
FC126
65703
0x6466
Targets
FC101
0x647E
Function
FC100
65728
0x647F
Signal Input
FC102A
65729
0x6480
Pickup
50
30000
F13
1000
65731
0x6482
Curve
21
FC161
65732
0x6483
TDM
60000
F2
100
x CT
65733
0x6484
Reset
FC265
65735
0x6486
Relays
0xFFFFFFFF
FC198
65737
0x6488
Block
0xFFFFFFFF
FC142
65739
0x648A
Events
FC126
65740
0x648B
Targets
FC101
0x64B6
Function
FC100
Y Y Y Y
65784
0x64B7
Signal Input
FC102A
Y Y
65786
0x64B9
Pickup
50
30000
Y Y Y Y
65788
0x64BB
Direction
65789
0x64BC
Pickup Delay
6000000
65791
0x64BE
Dropout Delay
6000000
F13
Y Y Y Y
65793
0x64C0
Relays
0xFFFFFFFF
FC198
Y Y Y Y
65795
0x64C2
Block
0xFFFFFFFF
FC142
Y Y Y Y
65797
0x64C4
Events
FC126
Y Y Y Y
65798
0x64C5
Targets
FC101
Y Y Y Y
x CT
F13
1000
FC164
F13
Y Y Y Y
0x64DD Function
FC100
Y Y
65823
0x64DE
Signal Input
FC102A
Y Y
65825
0x64E0
Pickup
50
30000
65827
0x64E2
Direction
65828
0x64E3
Pickup Delay
6000000
65830
0x64E5
Dropout Delay
6000000
65832
0x64E7
Relays
0xFFFFFFFF
65834
0x64E9
Block
65836
0x64EB
Events
65837
0x64EC
Targets
x CT
F13
1000
Y Y
FC164
F13
Y Y
F13
Y Y
FC198
Y Y
0xFFFFFFFF
FC142
Y Y
FC126
Y Y
FC101
Y Y
Function
FC100
Y Y
FC102A
Y Y
F13
1000
Y Y
FC164
0x6504
65862
0x6505
Signal Input
65864
0x6507
Pickup
50
30000
65866
0x6509
Direction
x CT
65867
0x650A
Pickup Delay
6000000
F13
Y Y
65869
0x650C
Dropout Delay
6000000
F13
Y Y
65871
0x650E
Relays
0xFFFFFFFF
FC198
Y Y
65873
0x6510
Block
0xFFFFFFFF
FC142
Y Y
11-177
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
65875
0x6512
Events
FC126
Y Y
65876
0x6513
Targets
FC101
Y Y
500
F3
63
0x652D
Pos-Seq Restraint
65903
0x652E
Forward ECA
90
?Lag
F0
75
65904
0x652F
40
90
F0
90
65905
0x6530
Forward Pickup
50
30000
x CT
F3
50
65906
0x6531
40
90
F0
90
65907
0x6532
Reverse Pickup
50
30000
x CT
F3
50
65908
0x6533
Block
0xFFFFFFFF
FC142
65910
0x6535
Events
FC126
65911
0x6536
Targets
FC101
FC100
Broken Conductor
65943
0x6556
Function
65945
0x6558
I_2/I_1 Ratio
200
1000
F1
200
65946
0x6559
I_1 Min
100
x CT
F2
10
65947
0x655A
I_1 Max
500
x CT
F2
150
65948
0x655B
Pickup Delay
6000000
F13
20000
65950
0x655D
Relays
0xFFFFFFFF
FC198
65952
0x655F
Block
0xFFFFFFFF
FC142
65954
0x6561
Events
FC126
65955
0x6562
Targets
FC101
Load Encroachment
65970
0x6571
Function
FC126
65972
0x6573
Minimum Voltage
150
x VT
F2
20
65973
0x6574
Reach
25000
ohms
F2
500
65974
0x6575
Angle
50
F0
30
65975
0x6576
Pickup Delay
6000000
F13
65977
0x6578
Dropout Delay
6000000
F13
65979
0x657A
Block
0xFFFFFFFF
FC142
65981
0x657C
Relays
0xFFFFFFFF
FC198
65983
0x657E
Events
FC126
65984
0x657F
Targets
FC101
0x659C
Function
66015
0x659E
Pickup
50
30000
x CT
FC100
F13
1000
66017
0x65A0
Alarm
700
1100
F1
800
66018
0x65A1
30
6000
min
F1
60
x tH
66019
0x65A2
100
600
F2
200
66020
0x65A3
Relays
0xFFFFFFFF
FC198
66022
0x65A5
Block
0xFFFFFFFF
FC142
66024
0x65A7
Events
FC126
66025
0x65A8
Targets
FC101
Function
FC100
Phase Reversal
66053
11-178
0x65C4
Y Y
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
66054
18000
F2
100
0x65C5
Pickup Delay
Y Y
66055
0x65C6
Dropout Delay
18000
F2
100
Y Y
66056
0x65C7
Block
0xFFFFFFFF
FC142
Y Y
66058
0x65C9
Output Relays
0xFFFFFFFF
FC198
Y Y
66060
0x65CB
Events
FC126
Y Y
66061
0x65CC
Targets
FC101
Y Y
66093
0x65EC
Function
FC100
Y Y Y Y
66094
0x65ED
Signal Input
0x12
0x14
FC103C
0x12
PUV 1
Y
66096
0x65EF
Mode
FC260
Y Y Y Y
66097
0x65F0
Pickup
150
x VT
F2
100
Y Y Y Y
66098
0x65F1
Minimum Voltage
150
x VT
F2
20
Y Y Y Y
66099
0x65F2
FC261
Y Y Y Y
66100
0x65F3
Undervoltage Curves
19
FC131
Y Y Y Y
66101
0x65F4
Pickup Delay
6000000
F13
1000
Y Y Y Y
66103
0x65F6
Relays
0xFFFFFFFF
FC198
Y Y Y Y
66105
0x65F8
Block
0xFFFFFFFF
FC142
Y Y Y Y
66107
0x65FA
Events
FC126
Y Y Y Y
66108
0x65FB
Targets
FC101
Y Y Y Y
66132
0x6613
Function
FC100
Y Y Y Y
66133
0x6614
Signal Input
0x12
0x14
FC103C
0x12
66135
0x6616
Mode
FC260
66136
0x6617
Pickup
150
x VT
F2
100
Y Y Y Y
66137
0x6618
Minimum Voltage
150
x VT
F2
20
Y Y Y Y
PUV 2
Y
Y Y Y Y
66138
0x6619
FC261
Y Y Y Y
66139
0x661A
Undervoltage Curves
19
FC131
Y Y Y Y
66140
0x661B
Pickup Delay
6000000
F13
1000
Y Y Y Y
66142
0x661D
Relays
0xFFFFFFFF
FC198
Y Y Y Y
66144
0x661F
Block
0xFFFFFFFF
FC142
Y Y Y Y
66146
0x6621
Events
FC126
Y Y Y Y
66147
0x6622
Targets
FC101
Y Y Y Y
66183
0x6646
Function
FC100
Y Y Y Y
66184
0x6647
Signal Input
0x22
0x24
FC103D 0x22
66186
0x6649
Pickup
150
x VT
F2
100
Y Y Y Y
x VT
F2
20
Y Y Y Y
FC131
Y Y Y Y
Aux UV 1
66187
0x664A
Minimum Voltage
150
66188
0x664B
Undervoltage Curves
19
1
s
66189
0x664C
Pickup Delay
6000000
F13
1000
Y Y Y Y
66191
0x664E
Relays
0xFFFFFFFF
FC198
Y Y Y Y
66193
0x6650
Block
0xFFFFFFFF
FC142
Y Y Y Y
66195
0x6652
Events
FC126
Y Y Y Y
66196
0x6653
Targets
FC101
Y Y Y Y
0x666B
Function
FC100
Y Y Y Y
Aux UV 2
66220
11-179
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
66221
0x666C
Signal Input
0x22
0x24
FC103D 0x22
66223
0x666E
Pickup
150
x VT
F2
100
Y Y Y Y
66224
0x666F
Minimum Voltage
150
x VT
F2
20
Y Y Y Y
66225
0x6670
Undervoltage Curves
19
FC131
Y Y Y Y
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
1
66226
0x6671
Pickup Delay
6000000
F13
1000
Y Y Y Y
66228
0x6673
Relays
0xFFFFFFFF
FC198
Y Y Y Y
66230
0x6675
Block
0xFFFFFFFF
FC142
Y Y Y Y
66232
0x6677
Events
FC126
Y Y Y Y
66233
0x6678
Targets
FC101
Y Y Y Y
66273
0x66A0
Function
FC100
Y Y Y Y
66274
0x66A1
Signal Input
0x12
0x14
FC103C
0x12
FC260
Y Y Y Y
F2
150
Y Y Y Y
POV 1
66276
0x66A3
Mode
66277
0x66A4
Pickup
300
x VT
66278
0x66A5
FC261
Y Y Y Y
66279
0x66A6
Pickup Delay
6000000
F13
1000
Y Y Y Y
66281
0x66A8
Dropout Delay
6000000
F13
1000
Y Y Y Y
66283
0x66AA
Relays
0xFFFFFFFF
FC198
Y Y Y Y
66285
0x66AC
Block
0xFFFFFFFF
FC142
Y Y Y Y
66287
0x66AE
Events
FC126
Y Y Y Y
66288
0x66AF
Targets
FC101
Y Y Y Y
66312
0x66C7
Function
FC100
Y Y Y Y
66313
0x66C8
Signal Input
0x12
0x14
FC103C
0x12
66315
0x66CA
Mode
FC260
Y Y Y Y
66316
0x66CB
Pickup
300
Y Y Y Y
66317
0x66CC
66318
6000000
s
s
POV 2
x VT
F2
150
FC261
Y Y Y Y
F13
1000
Y Y Y Y
66320
0x66CF
Dropout Delay
6000000
F13
1000
Y Y Y Y
66322
0x66D1
Relays
0xFFFFFFFF
FC198
Y Y Y Y
66324
0x66D3
Block
0xFFFFFFFF
FC142
Y Y Y Y
66326
0x66D5
Events
FC126
Y Y Y Y
66327
0x66D6
Targets
FC101
Y Y Y Y
66363
0x66FA
Function
FC100
Y Y Y Y
66364
0x66FB
Signal Input
0x22
0x24
FC103D 0x22
Aux OV 1
1
66366
0x66FD
Pickup
300
x VT
F2
150
Y Y Y Y
66367
0x66FE
Pickup Delay
6000000
F13
1000
Y Y Y Y
66369
0x6700
Dropout Delay
6000000
F13
1000
Y Y Y Y
66371
0x6702
Relays
0xFFFFFFFF
FC198
Y Y Y Y
66373
0x6704
Block
0xFFFFFFFF
FC142
Y Y Y Y
66375
0x6706
Events
FC126
Y Y Y Y
66376
0x6707
Targets
FC101
Y Y Y Y
0x671F
Function
FC100
Aux OV 2
66400
11-180
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
66401
0x22
0x24
FC103D 0x22
0x6720
Signal Input
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
1
66403
0x6722
Pickup
300
x VT
F2
150
66404
0x6723
Pickup Delay
6000000
F13
1000
66406
0x6725
Dropout Delay
6000000
F13
1000
66408
0x6727
Relays
0xFFFFFFFF
FC198
66410
0x6729
Block
0xFFFFFFFF
FC142
66412
0x672B
Events
FC126
66413
0x672C
Targets
FC101
FC100
F2
30
Y Y Y Y
FC161A
Y Y Y Y
Neutral OverVoltage 1
66453
0x6754
Function
66456
0x6757
Pickup
300
66457
0x6758
Curves
19
x VT
Y Y Y Y
66458
0x6759
Pickup Delay
6000000
F13
1000
Y Y Y Y
66460
0x675B
Dropout Delay
6000000
F13
1000
Y Y Y Y
66462
0x675D
Relays
0xFFFFFFFF
FC198
Y Y Y Y
66464
0x675F
Block
0xFFFFFFFF
FC142
Y Y Y Y
66466
0x6761
Events
FC126
Y Y Y Y
66467
0x6762
Targets
FC101
Y Y Y Y
FC100
Y Y Y Y
0x67AE
Function
66545
0x67B0
Pickup
300
x VT
F2
100
Y Y Y Y
66546
0x67B1
Pickup Delay
6000000
F13
1000
Y Y Y Y
66548
0x67B3
Dropout Delay
6000000
F13
1000
Y Y Y Y
66550
0x67B5
Relays
0xFFFFFFFF
FC198
Y Y Y Y
66552
0x67B7
Block
0xFFFFFFFF
FC142
Y Y Y Y
66554
0x67B9
Events
FC126
Y Y Y Y
66555
0x67BA
Targets
FC101
Y Y Y Y
0x67D2
Function
66581
0x67D4
Pickup
300
FC100
F2
100
66582
0x67D5
Pickup Delay
6000000
66584
0x67D7
Dropout Delay
6000000
F13
1000
F13
1000
66586
0x67D9
Relays
0xFFFFFFFF
FC198
66588
0x67DB Block
66590
0x67DD Events
0xFFFFFFFF
FC142
FC126
66591
0x67DE
Targets
FC101
Function
FC100
Y Y
x VT
0x67FB
66621
0x67FC
Signal Input
0x12
0x24
FC103B
0x12
Y Y
66622
0x67FD
Voltage Mode
FC260
Y Y
66623
0x67FE
Pickup
80
400
F2
105
Y Y
Y Y
V/Hz
66624
0x67FF
Curve
26
FC161D 7
66625
0x6800
TD Multiplier
60000
F2
100
Y Y
66626
0x6801
T Reset
600000
F12
100
Y Y
66628
0x6803
Block
0xFFFFFFFF
FC142
Y Y
11-181
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
66630
Output Relays
0xFFFFFFFF
FC198
0x6805
Y Y
66632
0x6807
Events
FC126
Y Y
66633
0x6808
Targets
FC101
Y Y
0x6813
Function
FC100
Y Y
66645
0x6814
Signal Input
0x12
0x24
FC103B
0x12
Y Y
FC260
Y Y
F2
105
Y Y
66646
0x6815
Voltage Mode
66647
0x6816
Pickup
80
400
66648
0x6817
Curve
26
FC161D 7
Y Y
66649
0x6818
TD Multiplier
60000
F2
100
Y Y
66650
0x6819
T Reset
600000
F12
100
Y Y
66652
0x681B
Block
0xFFFFFFFF
FC142
Y Y
66654
0x681D
Output Relays
0xFFFFFFFF
FC198
Y Y
66656
0x681F
Events
FC126
Y Y
66657
0x6820
Targets
FC101
Y Y
Signal Input
FC391
Y
Y
V/Hz
Out-of-Step
66740
0x6873
66741
0x6874
Function
FC100
66742
0x6875
10
50000
ohms
F2
200
66743
0x6876
10
50000
ohms
F2
200
66744
0x6877
Right Blinder
10
50000
ohms
F2
200
66745
0x6878
Left Blinder
10
50000
ohms
F2
200
Y
Y
66746
0x6879
Blinders RCA
40
90
F0
90
66747
0x687A
Pickup Delay
1000
F3
100
66748
0x687B
Trip Mode
FC384
66749
0x687C
1000
x CT
F2
100
66750
0x687D
Seal-in Delay
1000
F3
100
66751
0x687E
Block
0xFFFFFFFF
FC142
66753
0x6880
Output Relays
0xFFFFFFFF
FC198
66755
0x6882
Events
FC126
66756
0x6883
Targets
FC101
Function
FC100
Directional Power 1
66803
0x68B2
Y Y Y Y
66805
0x68B4
RCA
359
F0
180
Y Y Y Y
66806
0x68B5
Calibration
95
F2
Y Y Y Y
66807
0x68B6
Stage 1 SMIN
-1200
1200
x Rated F23
100
Y Y Y Y
66808
0x68B7
Stage 1 Delay
6000000
F13
500
Y Y Y Y
66810
0x68B9
Stage 2 SMIN
-1200
1200
x Rated F23
100
Y Y Y Y
66811
0x68BA
Stage 2 Delay
6000000
F13
20000
Y Y Y Y
66813
0x68BC
Relays
0xFFFFFFFF
FC198
Y Y Y Y
66815
0x68BE
Block
0xFFFFFFFF
FC142
Y Y Y Y
66817
0x68C0
Events
FC126
Y Y Y Y
66818
0x68C1
Targets
FC101
Y Y Y Y
66819
0x68C2
Signal Input
FC286
Directional Power 2
11-182
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
66842
FC100
0x68D9
Function
Y Y Y Y
66844
0x68DB RCA
359
F0
180
Y Y Y Y
66845
0x68DC Calibration
95
F2
Y Y Y Y
66846
-1200
1200
x Rated F23
100
Y Y Y Y
66847
0x68DE
Stage 1 Delay
6000000
F13
500
Y Y Y Y
66849
0x68E0
Stage 2 SMIN
-1200
1200
x Rated F23
100
Y Y Y Y
66850
0x68E1
Stage 2 Delay
6000000
F13
20000
Y Y Y Y
66852
0x68E3
Relays
0xFFFFFFFF
FC198
Y Y Y Y
66854
0x68E5
Block
0xFFFFFFFF
FC142
Y Y Y Y
66856
0x68E7
Events
FC126
Y Y Y Y
66857
0x68E8
Targets
FC101
Y Y Y Y
66858
0x68E9
Signal Input
FC286
FC100
FC272A
F2
20
FC276
0x690C
Function
66895
0x690E
Voltage
66896
0x690F
300
66897
0x6910
Current
x VT
66898
0x6911
30000
x CT
F3
60
66899
0x6912
Power Pickup
1200
CTxVT
F3
100
66900
0x6913
1200
CTxVT
F3
500
66901
0x6914
ECA
359
?Lag
F0
66902
0x6915
6000000
F13
200
66904
0x6917
Curve
19
66905
0x6918
Multiplier
200
66906
0x6919
Relays
0xFFFFFFFF
66908
0x691B
Block
66910
0x691D
Events
66911
0x691E
Targets
Trip Function
FC161B
F2
100
FC198
0xFFFFFFFF
FC142
FC126
FC101
FC100D 0
Reactive Power
66980
0x6963
66981
0x6964
200
x Rated F2
80
66982
0x6965
200
x Rated F2
80
66983
0x6966
60000
1000
F2
66984
0x6967
60000
F2
100
66985
0x6968
Trip Relays
0xFFFFFFFF
FC198
66987
0x696A
Alarm Function
FC100E
66988
0x696B
200
x Rated F2
85
66989
0x696C
200
x Rated F2
85
66990
0x696D
60000
F2
1000
66991
0x696E
60000
F2
100
66992
0x696F
60000
F2
50
66993
0x6970
Alarm Relays
0xFFFFFFFF
FC198
66995
0x6972
Block
0xFFFFFFFF
FC142
11-183
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
66997
0x6974
Events
FC126
66998
0x6975
Targets
FC101
Function
FC100
Y Y Y Y
FC103A
0x12
Y Y Y Y
F2
5900
Y Y Y Y
Underfrequency 1
67023
0x698E
67024
0x698F
Signal Input
0x12
0x22
67025
0x6990
Pickup
2000
6500
67026
0x6991
Pickup Delay
6000000
F13
2000
Y Y Y Y
67028
0x6993
Dropout Delay
6000000
F13
2000
Y Y Y Y
67030
0x6995
Minimum Voltage
1250
x VT
F13
700
Y Y Y Y
x CT
Hz
67032
0x6997
Minimum Current
30000
F13
200
Y Y Y Y
67034
0x6999
Relays
0xFFFFFFFF
FC198
Y Y Y Y
67036
0x699B
Block
0xFFFFFFFF
FC142
Y Y Y Y
67038
0x699D
Events
FC126
Y Y Y Y
67039
0x699E
Targets
FC101
Y Y Y Y
Underfrequency 2
67063
0x69B6
Function
FC100
Y Y Y Y
67064
0x69B7
Signal Input
0x12
0x22
FC103A
0x12
Y Y Y Y
67065
0x69B8
Pickup
2000
6500
Hz
F2
5900
Y Y Y Y
67066
0x69B9
Pickup Delay
6000000
F13
2000
Y Y Y Y
67068
0x69BB
Dropout Delay
6000000
F13
2000
Y Y Y Y
67070
1250
x VT
F13
700
Y Y Y Y
67072
0x69BF
30000
x CT
F13
200
Y Y Y Y
Minimum Current
67074
0x69C1
Relays
0xFFFFFFFF
FC198
Y Y Y Y
67076
0x69C3
Block
0xFFFFFFFF
FC142
Y Y Y Y
67078
0x69C5
Events
FC126
Y Y Y Y
67079
0x69C6
Targets
FC101
Y Y Y Y
Function
FC100
Y Y Y Y
Underfrequency 3
67103
0x69DE
67104
0x69DF
Signal Input
0x12
0x22
67105
0x69E0
Pickup
2000
6500
67106
0x69E1
Pickup Delay
6000000
F13
2000
Y Y Y Y
67108
0x69E3
Dropout Delay
6000000
F13
2000
Y Y Y Y
67110
0x69E5
Minimum Voltage
1250
x VT
F13
700
Y Y Y Y
x CT
Hz
FC103A
0x12
Y Y Y Y
F2
5900
Y Y Y Y
67112
0x69E7
Minimum Current
30000
F13
200
Y Y Y Y
67114
0x69E9
Relays
0xFFFFFFFF
FC198
Y Y Y Y
67116
0x69EB
Block
0xFFFFFFFF
FC142
Y Y Y Y
67118
0x69ED
Events
FC126
Y Y Y Y
67119
0x69EE
Targets
FC101
Y Y Y Y
Underfrequency 4
67143
0x6A06
Function
FC100
Y Y Y Y
67144
0x6A07
Signal Input
0x12
0x22
FC103A
0x12
Y Y Y Y
67145
0x6A08
Pickup
2000
6500
Hz
F2
5900
Y Y Y Y
67146
0x6A09
Pickup Delay
6000000
F13
2000
Y Y Y Y
67148
0x6A0B
Dropout Delay
6000000
F13
2000
Y Y Y Y
67150
1250
x VT
F13
700
Y Y Y Y
11-184
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
67152
Minimum Current
30000
F13
200
0x6A0F
x CT
Y Y Y Y
67154
0x6A11
Relays
0xFFFFFFFF
FC198
Y Y Y Y
67156
0x6A13
Block
0xFFFFFFFF
FC142
Y Y Y Y
67158
0x6A15
Events
FC126
Y Y Y Y
67159
0x6A16
Targets
FC101
Y Y Y Y
Underfrequency 5
67183
0x6A2E
Function
FC100
67184
0x6A2F
Signal Input
0x12
0x22
FC103A
0x12
67185
0x6A30
Pickup
2000
6500
F2
5900
Hz
67186
0x6A31
Pickup Delay
6000000
F13
2000
67188
0x6A33
Dropout Delay
6000000
F13
2000
67190
0x6A35
Minimum Voltage
1250
x VT
F13
700
x CT
67192
0x6A37
Minimum Current
30000
F13
200
67194
0x6A39
Relays
0xFFFFFFFF
FC198
67196
0x6A3B
Block
0xFFFFFFFF
FC142
67198
0x6A3D Events
FC126
67199
0x6A3E
Targets
FC101
Underfrequency 6
67223
0x6A56
Function
FC100
67224
0x6A57
Signal Input
0x12
0x22
FC103A
0x12
67225
0x6A58
Pickup
2000
6500
Hz
F2
5900
67226
0x6A59
Pickup Delay
6000000
F13
2000
67228
0x6A5B
Dropout Delay
6000000
F13
2000
67230
1250
x VT
F13
700
67232
0x6A5F
Minimum Current
30000
x CT
F13
200
67234
0x6A61
Relays
0xFFFFFFFF
FC198
67236
0x6A63
Block
0xFFFFFFFF
FC142
67238
0x6A65
Events
FC126
67239
0x6A66
Targets
FC101
Overfrequency 1
67273
0x6A88
Function
FC100
Y Y Y Y
67274
0x6A89
Signal Input
0x12
0x22
FC103A
0x12
Y Y Y Y
67275
0x6A8A
Pickup
2000
6500
F2
6050
Y Y Y Y
67276
0x6A8B
Pickup Delay
6000000
F13
5000
Y Y Y Y
67278
6000000
F13
5000
Y Y Y Y
67280
0x6A8F
Minimum Voltage
1250
x VT
F13
300
Y Y Y Y
Hz
67282
0x6A91
Relays
0xFFFFFFFF
FC198
Y Y Y Y
67284
0x6A93
Block
0xFFFFFFFF
FC142
Y Y Y Y
67286
0x6A95
Events
FC126
Y Y Y Y
67287
0x6A96
Targets
FC101
Y Y Y Y
Overfrequency 2
67311
0x6AAE
Function
FC100
Y Y Y Y
67312
0x6AAF
Signal Input
0x12
0x22
FC103A
0x12
Y Y Y Y
67313
0x6AB0
Pickup
2000
6500
Hz
F2
6050
Y Y Y Y
67314
0x6AB1
Pickup Delay
6000000
F13
5000
Y Y Y Y
11-185
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
67316
6000000
F13
5000
Y Y Y Y
x VT
0x6AB3
Dropout Delay
67318
0x6AB5
Minimum Voltage
1250
F13
300
Y Y Y Y
67320
0x6AB7
Relays
0xFFFFFFFF
FC198
Y Y Y Y
67322
0x6AB9
Block
0xFFFFFFFF
FC142
Y Y Y Y
67324
0x6ABB Events
FC126
Y Y Y Y
67325
0x6ABC Targets
FC101
Y Y Y Y
Overfrequency 3
67349
0x6AD4 Function
FC100
67350
0x12
0x22
FC103A
0x12
67351
0x6AD6 Pickup
2000
6500
Hz
F2
6050
67352
6000000
F13
5000
67354
6000000
F13
5000
x VT
67356
1250
F13
300
67358
0x6ADD Relays
0xFFFFFFFF
FC198
67360
0x6ADF
Block
0xFFFFFFFF
FC142
67362
0x6AE1
Events
FC126
67363
0x6AE2
Targets
FC101
Overfrequency 4
67387
0x6AFA
Function
FC100
67388
0x6AFB
Signal Input
0x12
0x22
FC103A
0x12
67389
0x6AFC
Pickup
2000
6500
Hz
F2
6050
67390
0x6AFD
Pickup Delay
6000000
F13
5000
67392
0x6AFF
Dropout Delay
6000000
F13
5000
67394
0x6B01
Minimum Voltage
1250
x VT
F13
300
67396
0x6B03
Relays
0xFFFFFFFF
FC198
67398
0x6B05
Block
0xFFFFFFFF
FC142
67400
0x6B07
Events
FC126
67401
0x6B08
Targets
FC101
FC100
Y Y Y Y
0x6B32
Function
67444
0x6B33
Signal Input
0x12
0x22
FC103A
0x12
Y Y Y Y
67445
0x6B34
Trend
FC253
Y Y Y Y
67446
0x6B35
Pickup
10
1500
F2
50
Y Y Y Y
Hz/sec
67447
0x6B36
Pickup Delay
6000000
F13
2000
Y Y Y Y
67449
0x6B38
Minimum Frequency
2000
8000
Hz
F2
4500
Y Y Y Y
67450
0x6B39
Maximum Frequency
2000
8000
Hz
F2
6500
Y Y Y Y
67451
0x6B3A
Minimum Voltage
1250
x VT
F13
700
Y Y Y Y
67453
0x6B3C
Minimum Current
30000
x CT
F13
200
Y Y Y Y
67455
0x6B3E
Relays
0xFFFFFFFF
FC198
Y Y Y Y
67457
0x6B40
Block
0xFFFFFFFF
FC142
Y Y Y Y
67459
0x6B42
Events
FC126
Y Y Y Y
67460
0x6B43
Targets
FC101
Y Y Y Y
0x6B5B
Function
FC100
Y Y Y Y
67485
0x6B5C
Signal Input
0x12
0x22
FC103A
0x12
Y Y Y Y
11-186
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
67486
0x6B5D Trend
FC253
67487
0x6B5E
Pickup
10
1500
Hz/sec
F2
50
Y Y Y Y
67488
0x6B5F
Pickup Delay
6000000
F13
2000
Y Y Y Y
67490
0x6B61
Minimum Frequency
2000
8000
Hz
F2
4500
Y Y Y Y
67491
0x6B62
Maximum Frequency
2000
8000
Hz
F2
6500
Y Y Y Y
67492
0x6B63
Minimum Voltage
1250
x VT
F13
700
Y Y Y Y
x CT
Y Y Y Y
67494
0x6B65
Minimum Current
30000
F13
200
Y Y Y Y
67496
0x6B67
Relays
0xFFFFFFFF
FC198
Y Y Y Y
67498
0x6B69
Block
0xFFFFFFFF
FC142
Y Y Y Y
67500
0x6B6B
Events
FC126
Y Y Y Y
67501
0x6B6C
Targets
FC101
Y Y Y Y
0x6B84
Function
FC100
67526
0x6B85
Signal Input
0x12
0x22
FC103A
0x12
Y
Y
67527
0x6B86
Trend
FC253
67528
0x6B87
Pickup
10
1500
Hz/sec
F2
50
67529
0x6B88
Pickup Delay
6000000
F13
2000
67531
0x6B8A
Minimum Frequency
2000
8000
Hz
F2
4500
67532
0x6B8B
Maximum Frequency
2000
8000
Hz
F2
6500
67533
0x6B8C
Minimum Voltage
1250
x VT
F13
700
x CT
67535
0x6B8E
Minimum Current
30000
F13
200
67537
0x6B90
Relays
0xFFFFFFFF
FC198
67539
0x6B92
Block
0xFFFFFFFF
FC142
67541
0x6B94
Events
FC126
67542
0x6B95
Targets
FC101
0x6BAD Function
FC100
67567
0x6BAE
Signal Input
0x12
0x22
FC103A
0x12
FC253
F2
50
67568
0x6BAF
Trend
67569
0x6BB0
Pickup
10
1500
Hz/sec
67570
0x6BB1
Pickup Delay
6000000
F13
2000
67572
0x6BB3
Minimum Frequency
2000
8000
Hz
F2
4500
67573
0x6BB4
Maximum Frequency
2000
8000
Hz
F2
6500
67574
0x6BB5
Minimum Voltage
1250
x VT
F13
700
67576
0x6BB7
Minimum Current
30000
x CT
F13
200
67578
0x6BB9
Relays
0xFFFFFFFF
FC198
67580
0x6BBB
Block
0xFFFFFFFF
FC142
67582
0x6BBD Events
FC126
67583
0x6BBE
FC101
FC100
Targets
0x6BD6 Function
67608
0x12
0x22
FC103A
0x12
67609
0x6BD8 Trend
FC253
67610
0x6BD9 Pickup
10
1500
Hz/sec
F2
50
67611
6000000
F13
2000
11-187
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
67613
2000
8000
Hz
F2
4500
67614
2000
8000
Hz
F2
6500
67615
1250
x VT
F13
700
67617
0x6BE0
Minimum Current
30000
x CT
F13
200
67619
0x6BE2
Relays
0xFFFFFFFF
FC198
67621
0x6BE4
Block
0xFFFFFFFF
FC142
67623
0x6BE6
Events
FC126
67624
0x6BE7
Targets
FC101
0x6BFF
Function
FC100
67649
0x6C00
Signal Input
0x12
0x22
FC103A
0x12
67650
0x6C01
Trend
FC253
67651
0x6C02
Pickup
10
1500
Hz/sec
F2
50
67652
0x6C03
Pickup Delay
6000000
F13
2000
67654
0x6C05
Minimum Frequency
2000
8000
Hz
F2
4500
67655
0x6C06
Maximum Frequency
2000
8000
Hz
F2
6500
67656
0x6C07
Minimum Voltage
1250
x VT
F13
700
x CT
67658
0x6C09
Minimum Current
30000
F13
200
67660
0x6C0B
Relays
0xFFFFFFFF
FC198
67662
0x6C0D Block
0xFFFFFFFF
FC142
67664
0x6C0F
Events
FC126
67665
0x6C10
Targets
FC101
FC103B
0x12
F2
40
0x6C29
Frequency Input
0x12
0x24
67691
0x6C2A
Minimum Voltage
10
110
67692
0x6C2B
Semicycles Set
20
F0
67693
0x6C2C
Semicycles Reset
F0
x VT
Fast Underfreq 1
67710
0x6C3D Function
FC100
67711
0x6C3E
Type
FC388
67712
0x6C3F
Underfrequency Pickup
2000
6500
Hz
F2
5900
67713
0x6C40
-1000
-10
Hz/sec
F22
-75
67714
0x6C41
Pickup Delay
6000000
F13
1000
67716
0x6C43
Reset Delay
6000000
F13
67718
0x6C45
Block
0xFFFFFFFF
FC142
67720
0x6C47
Relays
0xFFFFFFFF
FC198
67722
0x6C49
Events
FC126
67723
0x6C4A
Targets
FC101
Fast Underfreq 2
67730
0x6C51
Function
FC100
67731
0x6C52
Type
FC388
67732
0x6C53
Underfrequency Pickup
2000
6500
Hz
F2
5900
67733
0x6C54
-1000
-10
Hz/sec
F22
-75
67734
0x6C55
Pickup Delay
6000000
F13
1000
67736
0x6C57
Reset Delay
6000000
F13
11-188
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
67738
0x6C59
Block
0xFFFFFFFF
FC142
67740
0x6C5B
Relays
0xFFFFFFFF
FC198
67742
0x6C5D Events
FC126
67743
0x6C5E
Targets
FC101
FC100
Fast Underfreq 3
67750
0x6C65
Function
67751
0x6C66
Type
FC388
67752
0x6C67
Underfrequency Pickup
2000
6500
Hz
F2
5900
67753
0x6C68
-1000
-10
Hz/sec
F22
-75
67754
0x6C69
Pickup Delay
6000000
F13
1000
67756
0x6C6B
Reset Delay
6000000
F13
67758
0x6C6D Block
0xFFFFFFFF
FC142
67760
0x6C6F
Relays
0xFFFFFFFF
FC198
67762
0x6C71
Events
FC126
67763
0x6C72
Targets
FC101
FC100
Fast Underfreq 4
67770
0x6C79
Function
67771
0x6C7A
Type
FC388
67772
0x6C7B
Underfrequency Pickup
2000
6500
Hz
F2
5900
67773
0x6C7C
-1000
-10
Hz/sec
F22
-75
67774
6000000
F13
1000
67776
0x6C7F
Reset Delay
6000000
F13
67778
0x6C81
Block
0xFFFFFFFF
FC142
67780
0x6C83
Relays
0xFFFFFFFF
FC198
67782
0x6C85
Events
FC126
67783
0x6C86
Targets
FC101
FC100
FC388
F2
5900
Fast Underfreq 5
67790
0x6C8D Function
67791
0x6C8E
Type
67792
0x6C8F
Underfrequency Pickup
2000
6500
Hz
67793
0x6C90
-1000
-10
Hz/sec
F22
-75
67794
0x6C91
Pickup Delay
6000000
F13
1000
67796
0x6C93
Reset Delay
6000000
F13
67798
0x6C95
Block
0xFFFFFFFF
FC142
67800
0x6C97
Relays
0xFFFFFFFF
FC198
67802
0x6C99
Events
FC126
67803
0x6C9A
Targets
FC101
Fast Underfreq 6
67810
0x6CA1
Function
FC100
67811
0x6CA2
Type
FC388
67812
0x6CA3
Underfrequency Pickup
2000
6500
Hz
F2
5900
Y
Y
67813
0x6CA4
-1000
-10
Hz/sec
F22
-75
67814
0x6CA5
Pickup Delay
6000000
F13
1000
67816
0x6CA7
Reset Delay
6000000
F13
67818
0x6CA9
Block
0xFFFFFFFF
FC142
11-189
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
67820
0x6CAB Relays
0xFFFFFFFF
FC198
67822
0x6CAD Events
FC126
67823
0x6CAE
Targets
FC101
Fast Underfreq 7
67830
0x6CB5
Function
FC100
67831
0x6CB6
Type
FC388
67832
0x6CB7
Underfrequency Pickup
2000
6500
Hz
F2
5900
67833
0x6CB8
-1000
-10
Hz/sec
F22
-75
67834
0x6CB9
Pickup Delay
6000000
F13
1000
67836
6000000
F13
67838
0x6CBD Block
0xFFFFFFFF
FC142
67840
0x6CBF
Relays
0xFFFFFFFF
FC198
67842
0x6CC1
Events
FC126
67843
0x6CC2
Targets
FC101
Function
Fast Underfreq 8
67850
0x6CC9
FC100
67851
0x6CCA Type
FC388
67852
2000
6500
Hz
F2
5900
67853
-1000
-10
Hz/sec
F22
-75
67854
6000000
F13
1000
67856
0x6CCF
6000000
F13
67858
0x6CD1 Block
Reset Delay
0xFFFFFFFF
FC142
67860
0x6CD3 Relays
0xFFFFFFFF
FC198
67862
0x6CD5 Events
FC126
67863
0x6CD6 Targets
FC101
0x84CF
FC132A
Y Y Y Y
74001
0x84D0
0xFFFFFFFF
FC142
Y Y Y Y
74003
0x84D2
0xFFFFFFFF
FC142
Y Y Y Y
74005
0x84D4
0xFFFFFFFF
FC142
Y Y Y Y
74007
0x84D6
0xFFFFFFFF
FC142
Y Y Y Y
74009
0x84D8
0xFFFFFFFF
FC142
Y Y Y Y
74011
65535
F60_26
Group 1
13
Y Y Y Y
74024
0x84E7
Group 2 Name
65535
F60_26
Group 2
13
Y Y Y Y
74037
0x84F4
Group 3 Name
65535
F60_26
Group 3
13
Y Y Y Y
74050
0x8501
Group 4 Name
65535
F60_26
Group 4
13
Y Y Y Y
74063
0x850E
Group 5 Name
65535
F60_26
Group 5
13
Y Y Y Y
74076
0x851B
Group 6 Name
65535
F60_26
Group 6
13
Y Y Y Y
74089
0x8528
Change Inhibit 1
0xFFFFFFFF
FC142
Y Y Y Y
74091
0x852A
Change Inhibit 2
0xFFFFFFFF
FC142
Y Y Y Y
74093
0x852C
Change Inhibit 3
0xFFFFFFFF
FC142
Y Y Y Y
74095
0x852E
Change Inhibit 4
0xFFFFFFFF
FC142
Y Y Y Y
74097
0x8530
Change Inhibit 5
0xFFFFFFFF
FC142
Y Y Y Y
74099
0x8532
Change Inhibit 6
0xFFFFFFFF
FC142
Y Y Y Y
74101
0x8534
Change Inhibit 7
0xFFFFFFFF
FC142
Y Y Y Y
11-190
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
74103
0xFFFFFFFF
FC142
Y Y Y Y
Y Y Y Y
0x8536
Change Inhibit 8
74105
0x8538
Change Inhibit 9
0xFFFFFFFF
FC142
74107
0x853A
Change Inhibit 10
0xFFFFFFFF
FC142
Y Y Y Y
74109
0x853C
Change Inhibit 11
0xFFFFFFFF
FC142
Y Y Y Y
74111
0x853E
Change Inhibit 12
0xFFFFFFFF
FC142
Y Y Y Y
74113
0x8540
Change Inhibit 13
0xFFFFFFFF
FC142
Y Y Y Y
74115
0x8542
Change Inhibit 14
0xFFFFFFFF
FC142
Y Y Y Y
74117
0x8544
Change Inhibit 15
0xFFFFFFFF
FC142
Y Y Y Y
74119
0x8546
Change Inhibit 16
0xFFFFFFFF
FC142
Y Y Y Y
74121
0x8548
Events
FC126
Y Y Y Y
Function
FC100
0x855B
74141
0x855C
0xFFFFFFFF
FC142
74143
0x855E
FC177
74144
0x855F
Pickup Delay
10
60000
F2
100
74145
0x8560
Output Relay
0xFFFFFFFF
FC198
74147
0x8562
Block
0xFFFFFFFF
FC142
74149
0x8564
Events
FC126
74150
0x8565
Targets
FC101
0x8579
Function
FC100
74171
0x857A
Arming Input
0xFFFFFFFF
FC142
FC164A
74173
0x857C
Power Direction
74174
0x857D
Pickup MW Level
99
x Rated F2
74175
0x857E
Pickup Delay
20
18000
F2
1000
74176
0x857F
Output Relay
0xFFFFFFFF
FC198
74178
0x8581
Block
0xFFFFFFFF
FC142
74180
0x8583
Events
FC126
74181
0x8584
Targets
FC101
FC126
F0
25
FC126
F0
60
F0
0x85A1
Function
74211
0x85A2
TC Used Margin
25
0x85B5
Function
74231
0x85B6
Interval
300
74232
0x85B7
16
min
74233
0x85B8
Events
FC126
74234
0x85B9
Targets
FC101
FC126
F0
10
0x85C9
Function
74251
0x85CA
Minimum Time
300
min
74252
0x85CB
Events
FC126
74253
0x85CC
Targets
FC101
FC126
0x85DD Function
11-191
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
74271
Minimum Time
65000
F0
0x85DE
74272
0x85DF
Events
FC126
74273
0x85E0
Targets
FC101
0x85F1
Function
FC100D 0
74291
0x85F2
0xFFFFFFFF
FC198E
74293
0x85F4
Transition Mode
FC373
74294
0x85F5
25
300
x FLA
F2
125
74295
0x85F6
Start Timer
10
6000
F1
100
74296
0x85F7
Block
0xFFFFFFFF
FC142
74298
0x85F9
0xFFFFFFFF
FC198D 0
74300
0x85FB
Events
FC126
74301
0x85FC
Targets
FC101
FC142
F0
FC322
Breaker Control
74320
0x860F
Local Mode
0xFFFFFFFF
74322
0x8611
10
74323
0x8612
Local Open
min
Y Y Y Y
Y Y
Y
74324
0x8613
Local Close
FC322
74325
0x8614
Remote Open
0xFFFFFFFF
FC142
74327
0x8616
0xFFFFFFFF
FC142
Y Y
74329
0x8618
0xFFFFFFFF
FC142
Y Y
74331
0x861A
0xFFFFFFFF
FC142
74333
0x861C
Remote Close
0xFFFFFFFF
FC142
74335
0x861E
0xFFFFFFFF
FC142
Y
Y Y
74337
0x8620
0xFFFFFFFF
FC142
Y Y
74339
0x8622
0xFFFFFFFF
FC142
74341
0x8624
FC280
74342
0x8625
FC280
74343
0x8626
FC280
74344
0x8627
Events
FC126
Y Y Y Y
74345
0x8628
Targets
FC101
Y Y Y Y
Y
Y
Y Y
Y Y
0x8637
Local Mode
0xFFFFFFFF
FC142
74362
0x8639
Local Stop
FC322
74363
0x863A
Local Start
FC322
74364
0x863B
Remote Stop
0xFFFFFFFF
FC142
74366
0x863D
Remote Start
0xFFFFFFFF
FC142
74368
0x863F
Events
FC126
74369
0x8640
Targets
FC101
74393
0x8658
Function
FC100
Y Y Y Y
74394
0x8659
Input 1
0xFFFFFFFF
FC142
Y Y Y Y
74396
0x865B
Input 2
0xFFFFFFFF
FC142
Y Y Y Y
74398
0x865D
Input 3
0xFFFFFFFF
FC142
Y Y Y Y
74400
0x865F
Input 4
0xFFFFFFFF
FC142
Y Y Y Y
Trip Bus 1
11-192
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
74402
0x8661
Input 5
0xFFFFFFFF
FC142
Y Y Y Y
74404
0x8663
Input 6
0xFFFFFFFF
FC142
Y Y Y Y
74406
0x8665
Input 7
0xFFFFFFFF
FC142
Y Y Y Y
74408
0x8667
Input 8
0xFFFFFFFF
FC142
Y Y Y Y
74410
0x8669
Input 9
0xFFFFFFFF
FC142
Y Y Y Y
74412
0x866B
Input 10
0xFFFFFFFF
FC142
Y Y Y Y
74414
0x866D
Input 11
0xFFFFFFFF
FC142
Y Y Y Y
74416
0x866F
Input 12
0xFFFFFFFF
FC142
Y Y Y Y
74418
0x8671
Input 13
0xFFFFFFFF
FC142
Y Y Y Y
74420
0x8673
Input 14
0xFFFFFFFF
FC142
Y Y Y Y
74422
0x8675
Input 15
0xFFFFFFFF
FC142
Y Y Y Y
74424
0x8677
Input 16
0xFFFFFFFF
FC142
Y Y Y Y
74426
0x8679
Latching
FC126
Y Y Y Y
74427
0x867A
Reset
0xFFFFFFFF
FC142
Y Y Y Y
74429
0x867C
Pickup Delay
6000000
F13
Y Y Y Y
74431
0x867E
Dropout Delay
6000000
F13
Y Y Y Y
74433
0x8680
Relays
0xFFFFFFFF
FC198
Y Y Y Y
74435
0x8682
Block
0xFFFFFFFF
FC142
Y Y Y Y
74437
0x8684
Events
FC126
Y Y Y Y
74438
0x8685
Targets
FC101
Y Y Y Y
74452
0x8693
Function
FC100
Y Y Y Y
74453
0x8694
Input 1
0xFFFFFFFF
FC142
Y Y Y Y
74455
0x8696
Input 2
0xFFFFFFFF
FC142
Y Y Y Y
74457
0x8698
Input 3
0xFFFFFFFF
FC142
Y Y Y Y
74459
0x869A
Input 4
0xFFFFFFFF
FC142
Y Y Y Y
74461
0x869C
Input 5
0xFFFFFFFF
FC142
Y Y Y Y
74463
0x869E
Input 6
0xFFFFFFFF
FC142
Y Y Y Y
74465
0x86A0
Input 7
0xFFFFFFFF
FC142
Y Y Y Y
74467
0x86A2
Input 8
0xFFFFFFFF
FC142
Y Y Y Y
Trip Bus 2
74469
0x86A4
Input 9
0xFFFFFFFF
FC142
Y Y Y Y
74471
0x86A6
Input 10
0xFFFFFFFF
FC142
Y Y Y Y
74473
0x86A8
Input 11
0xFFFFFFFF
FC142
Y Y Y Y
74475
0x86AA
Input 12
0xFFFFFFFF
FC142
Y Y Y Y
74477
0x86AC
Input 13
0xFFFFFFFF
FC142
Y Y Y Y
74479
0x86AE
Input 14
0xFFFFFFFF
FC142
Y Y Y Y
74481
0x86B0
Input 15
0xFFFFFFFF
FC142
Y Y Y Y
74483
0x86B2
Input 16
0xFFFFFFFF
FC142
Y Y Y Y
74485
0x86B4
Latching
FC126
Y Y Y Y
74486
0x86B5
Reset
0xFFFFFFFF
FC142
Y Y Y Y
74488
0x86B7
Pickup Delay
6000000
F13
Y Y Y Y
74490
0x86B9
Dropout Delay
6000000
F13
Y Y Y Y
74492
0x86BB
Relays
0xFFFFFFFF
FC198
Y Y Y Y
74494
0x86BD Block
0xFFFFFFFF
FC142
Y Y Y Y
74496
0x86BF
FC126
Y Y Y Y
Events
11-193
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
74497
FC101
0x86C0
Targets
Y Y Y Y
Trip Bus 3
74511
0x86CE
Function
FC100
Y Y Y Y
74512
0x86CF
Input 1
0xFFFFFFFF
FC142
Y Y Y Y
74514
0x86D1
Input 2
0xFFFFFFFF
FC142
Y Y Y Y
74516
0x86D3
Input 3
0xFFFFFFFF
FC142
Y Y Y Y
74518
0x86D5
Input 4
0xFFFFFFFF
FC142
Y Y Y Y
74520
0x86D7
Input 5
0xFFFFFFFF
FC142
Y Y Y Y
74522
0x86D9
Input 6
0xFFFFFFFF
FC142
Y Y Y Y
74524
0x86DB Input 7
0xFFFFFFFF
FC142
Y Y Y Y
74526
0x86DD Input 8
0xFFFFFFFF
FC142
Y Y Y Y
74528
0x86DF
Input 9
0xFFFFFFFF
FC142
Y Y Y Y
74530
0x86E1
Input 10
0xFFFFFFFF
FC142
Y Y Y Y
74532
0x86E3
Input 11
0xFFFFFFFF
FC142
Y Y Y Y
74534
0x86E5
Input 12
0xFFFFFFFF
FC142
Y Y Y Y
74536
0x86E7
Input 13
0xFFFFFFFF
FC142
Y Y Y Y
74538
0x86E9
Input 14
0xFFFFFFFF
FC142
Y Y Y Y
74540
0x86EB
Input 15
0xFFFFFFFF
FC142
Y Y Y Y
74542
0x86ED
Input 16
0xFFFFFFFF
FC142
Y Y Y Y
74544
0x86EF
Latching
FC126
Y Y Y Y
FC142
Y Y Y Y
F13
Y Y Y Y
74545
0x86F0
Reset
0xFFFFFFFF
74547
0x86F2
Pickup Delay
6000000
74549
0x86F4
Dropout Delay
6000000
F13
Y Y Y Y
74551
0x86F6
Relays
0xFFFFFFFF
FC198
Y Y Y Y
74553
0x86F8
Block
0xFFFFFFFF
FC142
Y Y Y Y
74555
0x86FA
Events
FC126
Y Y Y Y
74556
0x86FB
Targets
FC101
Y Y Y Y
Trip Bus 4
74570
0x8709
Function
FC100
Y Y Y Y
74571
0x870A
Input 1
0xFFFFFFFF
FC142
Y Y Y Y
74573
0x870C
Input 2
0xFFFFFFFF
FC142
Y Y Y Y
74575
0x870E
Input 3
0xFFFFFFFF
FC142
Y Y Y Y
74577
0x8710
Input 4
0xFFFFFFFF
FC142
Y Y Y Y
74579
0x8712
Input 5
0xFFFFFFFF
FC142
Y Y Y Y
74581
0x8714
Input 6
0xFFFFFFFF
FC142
Y Y Y Y
74583
0x8716
Input 7
0xFFFFFFFF
FC142
Y Y Y Y
74585
0x8718
Input 8
0xFFFFFFFF
FC142
Y Y Y Y
74587
0x871A
Input 9
0xFFFFFFFF
FC142
Y Y Y Y
74589
0x871C
Input 10
0xFFFFFFFF
FC142
Y Y Y Y
74591
0x871E
Input 11
0xFFFFFFFF
FC142
Y Y Y Y
74593
0x8720
Input 12
0xFFFFFFFF
FC142
Y Y Y Y
74595
0x8722
Input 13
0xFFFFFFFF
FC142
Y Y Y Y
74597
0x8724
Input 14
0xFFFFFFFF
FC142
Y Y Y Y
74599
0x8726
Input 15
0xFFFFFFFF
FC142
Y Y Y Y
74601
0x8728
Input 16
0xFFFFFFFF
FC142
Y Y Y Y
11-194
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
74603
Latching
FC126
Y Y Y Y
Y Y Y Y
0x872A
74604
0x872B
Reset
0xFFFFFFFF
FC142
74606
0x872D
Pickup Delay
6000000
F13
Y Y Y Y
74608
0x872F
Dropout Delay
6000000
F13
Y Y Y Y
74610
0x8731
Relays
0xFFFFFFFF
FC198
Y Y Y Y
74612
0x8733
Block
0xFFFFFFFF
FC142
Y Y Y Y
74614
0x8735
Events
FC126
Y Y Y Y
74615
0x8736
Targets
FC101
Y Y Y Y
74629
0x8744
Function
FC100
Y Y Y Y
74630
0x8745
Input 1
0xFFFFFFFF
FC142
Y Y Y Y
74632
0x8747
Input 2
0xFFFFFFFF
FC142
Y Y Y Y
74634
0x8749
Input 3
0xFFFFFFFF
FC142
Y Y Y Y
74636
0x874B
Input 4
0xFFFFFFFF
FC142
Y Y Y Y
74638
0x874D
Input 5
0xFFFFFFFF
FC142
Y Y Y Y
74640
0x874F
Input 6
0xFFFFFFFF
FC142
Y Y Y Y
74642
0x8751
Input 7
0xFFFFFFFF
FC142
Y Y Y Y
74644
0x8753
Input 8
0xFFFFFFFF
FC142
Y Y Y Y
74646
0x8755
Input 9
0xFFFFFFFF
FC142
Y Y Y Y
74648
0x8757
Input 10
0xFFFFFFFF
FC142
Y Y Y Y
74650
0x8759
Input 11
0xFFFFFFFF
FC142
Y Y Y Y
74652
0x875B
Input 12
0xFFFFFFFF
FC142
Y Y Y Y
74654
0x875D
Input 13
0xFFFFFFFF
FC142
Y Y Y Y
74656
0x875F
Input 14
0xFFFFFFFF
FC142
Y Y Y Y
74658
0x8761
Input 15
0xFFFFFFFF
FC142
Y Y Y Y
74660
0x8763
Input 16
0xFFFFFFFF
FC142
Y Y Y Y
74662
0x8765
Latching
FC126
Y Y Y Y
74663
0x8766
Reset
0xFFFFFFFF
FC142
Y Y Y Y
Trip Bus 5
74665
0x8768
Pickup Delay
6000000
F13
Y Y Y Y
74667
0x876A
Dropout Delay
6000000
F13
Y Y Y Y
74669
0x876C
Relays
0xFFFFFFFF
FC198
Y Y Y Y
74671
0x876E
Block
0xFFFFFFFF
FC142
Y Y Y Y
74673
0x8770
Events
FC126
Y Y Y Y
74674
0x8771
Targets
FC101
Y Y Y Y
74688
0x877F
Function
FC100
Y Y Y Y
74689
0x8780
Input 1
0xFFFFFFFF
FC142
Y Y Y Y
74691
0x8782
Input 2
0xFFFFFFFF
FC142
Y Y Y Y
74693
0x8784
Input 3
0xFFFFFFFF
FC142
Y Y Y Y
74695
0x8786
Input 4
0xFFFFFFFF
FC142
Y Y Y Y
74697
0x8788
Input 5
0xFFFFFFFF
FC142
Y Y Y Y
74699
0x878A
Input 6
0xFFFFFFFF
FC142
Y Y Y Y
74701
0x878C
Input 7
0xFFFFFFFF
FC142
Y Y Y Y
74703
0x878E
Input 8
0xFFFFFFFF
FC142
Y Y Y Y
74705
0x8790
Input 9
0xFFFFFFFF
FC142
Y Y Y Y
Trip Bus 6
11-195
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
74707
0x8792
Input 10
0xFFFFFFFF
FC142
Y Y Y Y
74709
0x8794
Input 11
0xFFFFFFFF
FC142
Y Y Y Y
74711
0x8796
Input 12
0xFFFFFFFF
FC142
Y Y Y Y
74713
0x8798
Input 13
0xFFFFFFFF
FC142
Y Y Y Y
74715
0x879A
Input 14
0xFFFFFFFF
FC142
Y Y Y Y
74717
0x879C
Input 15
0xFFFFFFFF
FC142
Y Y Y Y
74719
0x879E
Input 16
0xFFFFFFFF
FC142
Y Y Y Y
74721
0x87A0
Latching
FC126
Y Y Y Y
74722
0x87A1
Reset
0xFFFFFFFF
FC142
Y Y Y Y
74724
0x87A3
Pickup Delay
6000000
F13
Y Y Y Y
74726
0x87A5
Dropout Delay
6000000
F13
Y Y Y Y
74728
0x87A7
Relays
0xFFFFFFFF
FC198
Y Y Y Y
74730
0x87A9
Block
0xFFFFFFFF
FC142
Y Y Y Y
74732
0x87AB
Events
FC126
Y Y Y Y
74733
0x87AC
Targets
FC101
Y Y Y Y
0x87BD Function
FC262
Y Y Y Y
74751
0x87BE
Signal Input
FC102A
Y Y
74752
0x87BF
50
30000
x CT
F3
1000
Y Y Y Y
74753
0x87C0
50
30000
x CT
F3
1000
Y Y Y Y
74754
0x87C1
Supervision
FC263
Y Y Y Y
74755
0x87C2
Breaker Closed
0xFFFFFFFF
FC142
Y Y Y Y
74757
0x87C4
T1 Pickup Delay
6000000
F13
120
Y Y Y Y
74759
0x87C6
T2 Pickup Delay
6000000
F13
120
Y Y Y Y
74761
0x87C8
T3 Pickup Delay
6000000
F13
120
Y Y Y Y
74763
0x87CA
50
30000
x CT
F3
1000
Y Y Y Y
74764
0x87CB
50
30000
x CT
F3
1000
Y Y Y Y
74765
0x87CC
Lowset Delay
6000000
F13
Y Y Y Y
74767
0x87CE
50
30000
x CT
F3
1000
Y Y Y Y
74768
0x87CF
50
30000
x CT
F3
1000
Y Y Y Y
74769
0x87D0
Dropout Delay
6000000
F13
100
Y Y Y Y
74771
0x87D2
Relays
0xFFFFFFFF
FC198
Y Y Y Y
74773
0x87D4
Block
0xFFFFFFFF
FC142
Y Y Y Y
74775
0x87D6
Events
FC126
Y Y Y Y
74776
0x87D7
Targets
FC101
Y Y Y Y
0x87E5
Function
FC262
Y Y
74791
0x87E6
Signal Input
FC102A
Y Y
74792
0x87E7
50
30000
x CT
F3
1000
Y Y
74793
0x87E8
50
30000
x CT
F3
1000
Y Y
74794
0x87E9
Supervision
FC263
Y Y
74795
0x87EA
Breaker Closed
0xFFFFFFFF
FC142
Y Y
74797
0x87EC
T1 Pickup Delay
6000000
F13
120
Y Y
74799
0x87EE
T2 Pickup Delay
6000000
F13
120
Y Y
11-196
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
74801
0x87F0
T3 Pickup Delay
6000000
F13
120
Y Y
74803
0x87F2
50
30000
x CT
F3
1000
Y Y
74804
0x87F3
50
30000
x CT
F3
1000
Y Y
74805
0x87F4
Lowset Delay
6000000
F13
Y Y
74807
0x87F6
50
30000
x CT
F3
1000
Y Y
74808
0x87F7
50
30000
x CT
F3
1000
Y Y
74809
0x87F8
Dropout Delay
6000000
F13
100
Y Y
74811
0x87FA
Relays
0xFFFFFFFF
FC198
Y Y
74813
0x87FC
Block
0xFFFFFFFF
FC142
Y Y
74815
0x87FE
Events
FC126
Y Y
74816
0x87FF
Targets
FC101
Y Y
0x880D
Function
FC262
74831
0x880E
Signal Input
FC102A
74832
0x880F
50
30000
x CT
F3
1000
74833
0x8810
50
30000
x CT
F3
1000
74834
0x8811
Supervision
FC263
74835
0x8812
Breaker Closed
0xFFFFFFFF
FC142
74837
0x8814
T1 Pickup Delay
6000000
F13
120
74839
0x8816
T2 Pickup Delay
6000000
F13
120
74841
0x8818
T3 Pickup Delay
6000000
F13
120
74843
0x881A
50
30000
x CT
F3
1000
74844
0x881B
50
30000
x CT
F3
1000
74845
0x881C
Lowset Delay
6000000
F13
74847
0x881E
50
30000
x CT
F3
1000
74848
0x881F
50
30000
x CT
F3
1000
74849
0x8820
Dropout Delay
6000000
F13
100
74851
0x8822
Relays
0xFFFFFFFF
FC198
74853
0x8824
Block
0xFFFFFFFF
FC142
74855
0x8826
Events
FC126
74856
0x8827
Targets
FC101
0xFFFFFFFF
FC142
Y Y Y Y
0x883F
External Initiate
74882
0x8841
Initiate IN1
0xFFFFFFFF
FC142
0x80C002 2
Y Y Y Y
74884
0x8843
Initiate IN2
0xFFFFFFFF
FC142
Y Y Y Y
74886
0x8845
Initiate IN3
0xFFFFFFFF
FC142
0x80C602 2
Y Y Y Y
74888
0x8847
Initiate IN4
0xFFFFFFFF
FC142
0x80C802 2
Y Y Y Y
74890
0x8849
Initiate IN5
0xFFFFFFFF
FC142
0x80D802 2
Y Y Y Y
74892
0x884B
Initiate IN6
0xFFFFFFFF
FC142
Y Y Y Y
74894
0x884D
Initiate IN7
0xFFFFFFFF
FC142
0x80DE02 2
Y Y Y Y
74896
0x884F
Initiate IN8
0xFFFFFFFF
FC142
0x80E002 2
Y Y Y Y
74898
0x8851
Initiate IN9
0xFFFFFFFF
FC142
0x80EC02 2
Y Y Y Y
74900
0x8853
Initiate IN10
0xFFFFFFFF
FC142
0x80F202 2
Y Y Y Y
74902
0x8855
Initiate IN11
0xFFFFFFFF
FC142
Y Y Y Y
74904
0x8857
Initiate IN12
0xFFFFFFFF
FC142
Y Y Y Y
11-197
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
74906
0x8859
0xFFFFFFFF
FC142
74908
0x885B
Initiate IN14
0xFFFFFFFF
FC142
Y Y Y Y
74910
0x885D
Initiate IN15
0xFFFFFFFF
FC142
Y Y Y Y
Initiate IN13
Y Y Y Y
0x8867
External Initiate
0xFFFFFFFF
FC142
Y Y
74922
0x8869
Initiate IN1
0xFFFFFFFF
FC142
Y Y
74924
0x886B
Initiate IN2
0xFFFFFFFF
FC142
Y Y
74926
0x886D
Initiate IN3
0xFFFFFFFF
FC142
Y Y
74928
0x886F
Initiate IN4
0xFFFFFFFF
FC142
Y Y
74930
0x8871
Initiate IN5
0xFFFFFFFF
FC142
Y Y
74932
0x8873
Initiate IN6
0xFFFFFFFF
FC142
Y Y
74934
0x8875
Initiate IN7
0xFFFFFFFF
FC142
Y Y
74936
0x8877
Initiate IN8
0xFFFFFFFF
FC142
Y Y
74938
0x8879
Initiate IN9
0xFFFFFFFF
FC142
Y Y
74940
0x887B
Initiate IN10
0xFFFFFFFF
FC142
Y Y
74942
0x887D
Initiate IN11
0xFFFFFFFF
FC142
Y Y
74944
0x887F
Initiate IN12
0xFFFFFFFF
FC142
Y Y
74946
0x8881
Initiate IN13
0xFFFFFFFF
FC142
Y Y
74948
0x8883
Initiate IN14
0xFFFFFFFF
FC142
Y Y
74950
0x8885
Initiate IN15
0xFFFFFFFF
FC142
Y Y
0x888F
External Initiate
0xFFFFFFFF
FC142
74962
0x8891
Initiate IN1
0xFFFFFFFF
FC142
74964
0x8893
Initiate IN2
0xFFFFFFFF
FC142
74966
0x8895
Initiate IN3
0xFFFFFFFF
FC142
74968
0x8897
Initiate IN4
0xFFFFFFFF
FC142
74970
0x8899
Initiate IN5
0xFFFFFFFF
FC142
74972
0x889B
Initiate IN6
0xFFFFFFFF
FC142
74974
0x889D
Initiate IN7
0xFFFFFFFF
FC142
74976
0x889F
Initiate IN8
0xFFFFFFFF
FC142
74978
0x88A1
Initiate IN9
0xFFFFFFFF
FC142
74980
0x88A3
Initiate IN10
0xFFFFFFFF
FC142
74982
0x88A5
Initiate IN11
0xFFFFFFFF
FC142
74984
0x88A7
Initiate IN12
0xFFFFFFFF
FC142
74986
0x88A9
Initiate IN13
0xFFFFFFFF
FC142
74988
0x88AB
Initiate IN14
0xFFFFFFFF
FC142
74990
0xFFFFFFFF
FC142
Synchrocheck 1 Setup
75010
0x88C1
Function
FC126
Y Y
75012
0x88C3
0x12
0x24
FC103B
0x12
Y Y
75014
0x88C5
0x12
0x24
FC103B
0x22
Y Y
75015
0x88C6
500
Hz
F2
20
Y Y
75016
0x88C7
100
F0
20
Y Y
75017
0x88C8
10
600000
F10
2000
Y Y
75019
0x88CA
10
Hz
F2
Y Y
11-198
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
75023
0x88CE
FC283
75024
0x88CF
150
x VT
F2
80
Y Y
75025
0x88D0
150
x VT
F2
80
Y Y
75026
0x88D1
150
x VT
F2
20
Y Y
x VT
Y Y
75027
0x88D2
150
F2
20
Y Y
75028
0x88D3
Relays
0xFFFFFFFF
FC198
Y Y
75030
0x88D5
Block
0xFFFFFFFF
FC142
Y Y
75032
0x88D7
Events
FC126
Y Y
75033
0x88D8
Targets
FC101
Y Y
F60_26
Manual Cls 13
Blk
0x8907
Name
65535
75093
0x8914
Function
75094
0x8915
6000000
75096
0x8917
75097
0x8918
75098
0x8919
75099
0x891A
75100
0x891B
75101
0x891C
75102
0x891D
75103
0x891E
100
F0
75104
0x891F
100
F0
75105
0x8920
100
F0
75106
0x8921
100
F0
75107
0x8922
100
F0
75108
0x8923
100
F0
75109
0x8924
100
F0
FC100A
F13
5000
FC126A
FC126A
FC126A
FC126A
FC126A
FC126A
FC126A
75110
0x8925
0xFFFF
FC132
65535
75111
0x8926
Relays
0xFFFFFFFF
FC198
75113
0x8928
Events
FC126
75114
0x8929
Targets
FC101
0x8946
Function
FC100A
75145
0x8948
External Initiation
0xFFFFFFFF
FC142
75147
0x894A
6000000
F13
1000000
75149
0x894C
6000000
F13
100000
75151
0x894E
FC126A
75152
0x894F
FC126A
75153
0x8950
FC126A
75154
0x8951
FC126A
75155
0x8952
FC126A
75156
0x8953
FC126A
75157
0x8954
FC126A
11-199
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
75158
100
F0
0x8955
75159
0x8956
100
F0
75160
0x8957
100
F0
75161
0x8958
100
F0
75162
0x8959
100
F0
75163
0x895A
100
F0
75164
0x895B
100
F0
75165
0x895C
0xFFFF
FC132
65535
75166
0x895D
Relays
0xFFFFFFFF
FC198
75168
0x895F
Block
0xFFFFFFFF
FC142
75170
0x8961
Events
FC126
75171
0x8962
Targets
FC101
Undervoltage Restoration
75203
0x8982
Ph UV Name
65535
F60_26
Ph UV
Restore
13
75216
0x898F
Aux UV Name
65535
F60_26
Aux UV
Restore
13
75229
0x899C
Function
FC100B
75230
0x899D
Initiation
FC279
75232
0x899F
Minimum Voltage
1250
x VT
F13
900
75234
0x89A1
Restore Delay
6000000
F13
10000
75236
0x89A3
Incomplete Sequence
Time
10000
min
F0
100
75237
0x89A4
Synchrocheck
Supervision
FC280
75238
0x89A5
Relays
0xFFFFFFFF
FC198
75240
0x89A7
Block
0xFFFFFFFF
FC142
75242
0x89A9
Events
FC126
75243
0x89AA
Targets
FC101
Underfrequency Restoration
75273
0x89C8
Function
FC100B
75274
0x89C9
Initiation
12
FC287
75276
0x89CB
Minimum Voltage
1250
x VT
F13
900
75278
2000
6500
Hz
F2
5990
75279
0x89CE
Restore Delay
6000000
F13
10000
75281
0x89D0
Incomplete Sequence
Time
10000
min
F0
100
75282
0x89D1
Synchrocheck
Supervision
FC280
75283
0x89D2
Relays
0xFFFFFFFF
FC198
75285
0x89D4
Block
0xFFFFFFFF
FC142
75287
0x89D6
Events
FC126
75288
0x89D7
Targets
FC101
FC284
0xFFFFFFFF
FC142
0x89E3
Function
11-200
0x89F7
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
75322
0x89F9
0xFFFFFFFF
FC142
75324
0x89FB
6000000
F13
75326
0x89FD
0xFFFFFFFF
FC142
75328
0x89FF
Tie-BKR Conn&Closed
0xFFFFFFFF
FC142
75330
0x8A01
Tie-BKR Connected
0xFFFFFFFF
FC142
75332
0x8A03
Inc 1 Transformer
Lockout
0xFFFFFFFF
FC142
75334
0x8A05
0xFFFFFFFF
FC142
75336
0x8A07
0xFFFFFFFF
FC142
75338
0x8A09
FC126
75339
0x8A0A
0xFFFFFFFF
FC142
75341
0x8A0C
UV On Other Source
0xFFFFFFFF
FC142
75343
0x8A0E
6000000
75345
0x8A10
0xFFFFFFFF
F13
3000
FC142
75347
0x8A12
6000000
F13
1000
75349
0x8A14
0xFFFFFFFF
75351
0x8A16
0xFFFFFFFF
FC142
FC142
75353
0x8A18
0xFFFFFFFF
FC142
75355
0x8A1A
0xFFFFFFFF
FC142
75357
0x8A1C
0xFFFFFFFF
FC142
75359
0x8A1E
0xFFFFFFFF
FC142
75361
0x8A20
Block Transfer
0xFFFFFFFF
FC142
75363
0x8A22
Events
FC126
75364
0x8A23
Targets
FC101
FC142
FC142
F13
0x8A2A
0xFFFFFFFF
75373
0x8A2C
0xFFFFFFFF
75375
0x8A2E
6000000
75377
0x8A30
0xFFFFFFFF
FC142
75379
0x8A32
Tie-BKR Conn&Closed
0xFFFFFFFF
FC142
75381
0x8A34
Tie-BKR Connected
0xFFFFFFFF
FC142
75383
0x8A36
Inc 2 Transformer
Lockout
0xFFFFFFFF
FC142
75385
0x8A38
0xFFFFFFFF
FC142
75387
0x8A3A
0xFFFFFFFF
FC142
75389
0x8A3C
FC126
75390
0xFFFFFFFF
FC142
75392
0x8A3F
UV On Other Source
0xFFFFFFFF
FC142
75394
0x8A41
6000000
F13
3000
75396
0x8A43
0xFFFFFFFF
FC142
75398
0x8A45
6000000
F13
1000
75400
0x8A47
0xFFFFFFFF
FC142
75402
0x8A49
0xFFFFFFFF
FC142
75404
0x8A4B
0xFFFFFFFF
FC142
75406
0xFFFFFFFF
FC142
75408
0x8A4F
0xFFFFFFFF
FC142
s
s
11-201
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
75410
0x8A51
0xFFFFFFFF
FC142
75412
0x8A53
Block Transfer
0xFFFFFFFF
FC142
75414
0x8A55
Events
FC126
75415
0x8A56
Targets
FC101
FC142
FC142
F13
0x8A65
Tie-BKR Connected
0xFFFFFFFF
75432
0x8A67
0xFFFFFFFF
75434
0x8A69
6000000
75436
0x8A6B
0xFFFFFFFF
FC142
75438
0xFFFFFFFF
FC142
75440
0x8A6F
Tie-BKR Closed
0xFFFFFFFF
FC142
75442
0x8A71
0xFFFFFFFF
FC142
75444
0x8A73
0xFFFFFFFF
FC142
75447
0x8A76
Block Transfer
0xFFFFFFFF
FC142
75449
0x8A78
Events
FC126
75450
0x8A79
Targets
FC101
Y
Y
AR1 Setup
75470
0x8A8D Function
FC126
75471
0x8A8E
F0
75472
0x8A8F
Block/Cancel
0xFFFFFFFF
FC142
75474
0x8A91
Manual Close
0xFFFFFFFF
FC142
75476
0x8A93
6000000
F13
10000
75478
0x8A95
Breaker Closed
0xFFFFFFFF
FC142
75480
0x8A97
Breaker Opened
0xFFFFFFFF
FC142
75482
0x8A99
FC126A
75483
0x8A9A
FC126A
75484
0x8A9B
6000000
F13
60000
75486
0xFFFFFFFF
FC142
75488
0x8A9F
Add Delay
0xFFFFFFFF
FC142
75490
0x8AA1
Delay
6000000
F13
75492
0x8AA3
Incomplete Sequence
Time
6000000
F13
5000
75494
0x8AA5
Reset Time
6000000
F13
60000
75496
0x8AA7
Reduce Maximum To 1
0xFFFFFFFF
FC142
75498
0x8AA9
Reduce Maximum To 2
0xFFFFFFFF
FC142
75500
0xFFFFFFFF
FC142
75502
FC280
75503
0x8AAE
0xFFFFFFFF
FC198
75505
0x8AB0
0xFFFFFFFF
FC198
75507
0x8AB2
0xFFFFFFFF
FC198
75509
0x8AB4
Setup Events
FC126
AR1 Initiate
75520
0x8ABF
External Initiate
0xFFFFFFFF
FC142
75522
0x8AC1
Initiate IN1
0xFFFFFFFF
FC142
0x80C002 2
11-202
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
75524
0x8AC3
Initiate IN2
0xFFFFFFFF
FC142
0x80C202 2
75526
0x8AC5
Initiate IN3
0xFFFFFFFF
FC142
0x80C602 2
75528
0x8AC7
Initiate IN4
0xFFFFFFFF
FC142
0x80C802 2
75530
0x8AC9
Initiate IN5
0xFFFFFFFF
FC142
0x80D802 2
75532
0x8ACB
Initiate IN6
0xFFFFFFFF
FC142
0x80DA02 2
75534
0xFFFFFFFF
FC142
0x80DE02 2
75536
0x8ACF
Initiate IN8
0xFFFFFFFF
FC142
0x80E002 2
75538
0xFFFFFFFF
FC142
0x80EC02 2
75540
0xFFFFFFFF
FC142
0x80F202 2
75542
0xFFFFFFFF
FC142
75544
0xFFFFFFFF
FC142
75546
0xFFFFFFFF
FC142
75548
0xFFFFFFFF
FC142
75550
0xFFFFFFFF
FC142
AR1 Shot 1
75570
0x8AF1
Dead Time 1
100
6000000
75572
0x8AF3
F13
1000
FC126A
75573
0x8AF4
FC126A
75574
0x8AF5
FC126A
75575
0x8AF6
FC126A
75576
0x8AF7
FC126A
75577
0x8AF8
FC126A
75578
0x8AF9
FC126A
75579
0x8AFA
100
F0
75580
0x8AFB
100
F0
75581
0x8AFC
100
F0
75582
0x8AFD
100
F0
75583
0x8AFE
100
F0
75584
0x8AFF
100
F0
75585
0x8B00
100
F0
75586
0x8B01
0xFFFF
FC132
65535
F13
2000
AR1 Shot 2
75587
0x8B02
Dead Time 2
100
6000000
75589
0x8B04
FC126A
75590
0x8B05
FC126A
75591
0x8B06
FC126A
75592
0x8B07
FC126A
75593
0x8B08
FC126A
75594
0x8B09
FC126A
75595
0x8B0A
FC126A
75596
0x8B0B
100
F0
75597
0x8B0C
100
F0
75598
100
F0
75599
0x8B0E
100
F0
11-203
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
75600
100
F0
0x8B0F
75601
0x8B10
100
F0
75602
0x8B11
100
F0
75603
0x8B12
0xFFFF
FC132
65535
F13
3000
Y
Y
AR1 Shot 3
75604
0x8B13
Dead Time 3
100
6000000
75606
0x8B15
FC126A
75607
0x8B16
FC126A
75608
0x8B17
FC126A
75609
0x8B18
FC126A
75610
0x8B19
FC126A
75611
0x8B1A
FC126A
75612
0x8B1B
FC126A
75613
0x8B1C
100
F0
75614
100
F0
75615
0x8B1E
100
F0
75616
0x8B1F
100
F0
75617
0x8B20
100
F0
75618
0x8B21
100
F0
75619
0x8B22
100
75620
0x8B23
0xFFFF
F0
FC132
65535
AR1 Shot 4
75621
0x8B24
Dead Time 4
100
6000000
F13
4000
75623
0x8B26
FC126A
75624
0x8B27
FC126A
75625
0x8B28
FC126A
75626
0x8B29
FC126A
75627
0x8B2A
FC126A
75628
0x8B2B
FC126A
75629
0x8B2C
FC126A
75630
100
F0
75631
0x8B2E
100
F0
75632
0x8B2F
100
F0
75633
0x8B30
100
F0
75634
0x8B31
100
F0
75635
0x8B32
100
F0
75636
0x8B33
100
F0
75637
0x8B34
0xFFFF
FC132
65535
FC267
0x8B41
Function
75651
0x8B42
50
F0
25
75652
0x8B43
Relays
0xFFFFFFFF
/hour
FC198
75654
0x8B45
Events
FC126
11-204
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
75670
0x8B55
Function
FC126
75672
0x8B57
30000
x CT
F13
17000
75674
0x8B59
30000
x CT
F13
18000
75676
0x8B5B
30000
x CT
F13
19000
75678
50
30000
x CT
F13
20000
75680
0x8B5F
Lockout
FC126
75681
0x8B60
Events
FC126
Function
FC126
0x8B73
75702
0x8B75
50
30000
x CT
F13
1000
75704
0x8B77
50
30000
x CT
F13
300
75706
0x8B79
Pickup Time
6000000
F13
20
75708
0x8B7B
Dropout Time
6000000
F13
20
75710
0x8B7D Events
FC126
65535
F60_26
VT Fuse
Fail1
13
Y Y Y Y
VT Fuse Fail 1
75990
0x8C95
Name
76003
0x8CA2
Function
FC100A
Y Y Y Y
76005
0x8CA4
Relays
0xFFFFFFFF
FC198
Y Y Y Y
76007
0x8CA6
Events
FC126
Y Y Y Y
76008
0x8CA7
Targets
FC101
Y Y Y Y
Name
65535
F60_26
VT Fuse
Fail2
13
VT Fuse Fail 2
76015
0x8CAE
76028
0x8CBB Function
FC100A
76030
0x8CBD Relays
0xFFFFFFFF
FC198
76032
0x8CBF
Events
FC126
76033
0x8CC0
Targets
FC101
Arc Flash 1
76050
0x8CD1 Function
FC100
Y Y Y Y
76051
FC102A
Y Y
76052
50
30000
x CT
F3
2000
Y Y Y Y
76053
50
30000
x CT
F3
1000
Y Y Y Y
76054
FC126
Y Y Y Y
76055
FC126
Y Y Y Y
76056
FC126
Y Y Y Y
76057
FC126
Y Y Y Y
76070
0x8CE5
Block
0xFFFFFFFF
FC142
Y Y Y Y
76072
0x8CE7
0xFFFFFFFF
FC198
Y Y Y Y
76074
0x8CE9
Events
FC126
Y Y Y Y
76075
0x8CEA
Targets
FC101
Y Y Y Y
FC100A
F2
10
F2
90
W1 Harmonic Derating
80000
0x9C3F
Function
80001
0x9C40
100
80002
0x9C41
Pickup
98
x CT
11-205
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
80003
60000
F0
10
0x9C42
Pickup Delay
80004
0x9C43
Block
0xFFFFFFFF
FC142
80006
0x9C45
Relays
0xFFFFFFFF
FC198
80008
0x9C47
Events
FC126
80009
0x9C48
Targets
FC101
FC100A
F2
10
F2
90
W2 Harmonic Derating
80010
0x9C49
Function
80011
0x9C4A
100
80012
0x9C4B
Pickup
98
80013
0x9C4C
Pickup Delay
60000
F0
10
80014
0x9C4D Block
0xFFFFFFFF
FC142
80016
0x9C4F
Relays
0xFFFFFFFF
FC198
x CT
s
80018
0x9C51
Events
FC126
80019
0x9C52
Targets
FC101
FC100A
F2
10
F2
90
F0
10
W3 Harmonic Derating
80020
0x9C53
Function
80021
0x9C54
100
x CT
80022
0x9C55
Pickup
98
80023
0x9C56
Pickup Delay
60000
80024
0x9C57
Block
0xFFFFFFFF
FC142
80026
0x9C59
Relays
0xFFFFFFFF
FC198
80028
0x9C5B
Events
FC126
80029
0x9C5C
Targets
FC101
FC100A
Y
Y
Wndg Hottest-Spot
80040
0x9C67
Function
80041
0x9C68
Pickup
50
300
?C
F0
140
80042
0x9C69
Pickup Delay
60000
min
F0
80043
0x9C6A
Block
0xFFFFFFFF
FC142
80045
0x9C6C
Relays
0xFFFFFFFF
FC198
80047
0x9C6E
Events
FC126
80048
0x9C6F
Targets
FC101
FC100A
F1
20
F0
10
0x9C7B
Function
80061
0x9C7C
Pickup
11
100
80062
60000
80063
0x9C7E
Block
0xFFFFFFFF
FC142
80065
0x9C80
Relays
0xFFFFFFFF
FC198
80067
0x9C82
Events
FC126
80068
0x9C83
Targets
FC101
Function
FC100A
min
0x9C8F
80081
0x9C90
500000000
hrs
F13
80083
0x9C92
Pickup
500000000
hrs
F13
20000000 2
0
80085
0x9C94
Block
0xFFFFFFFF
FC142
80087
0x9C96
Relays
0xFFFFFFFF
FC198
11-206
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
80089
0x9C98
Events
FC126
80090
0x9C99
Targets
FC101
FC100A
0x9CAD Function
80111
0x9CAE
Delay
60000
F2
500
80112
0x9CAF
Block
0xFFFFFFFF
FC142
80114
0x9CB1
Relays
0xFFFFFFFF
FC198
80116
0x9CB3
Events
FC126
80117
0x9CB4
Targets
FC101
DGA Monitoring
80130
0x9CC1
IP Address
0xDFFFFFFE
F70
80132
0x9CC3
Port
10000
F0
502
80133
0x9CC4
Slave ID
254
F0
80134
0x9CC5
Device Type
FC380
FC100A
F10
0x9CD5 Function
80151
999999
hrs
hrs
80153
1000000
F10
1000
80155
0xFFFFFFFF
FC198
80157
0x9CDC Block
0xFFFFFFFF
FC142
80159
0x9CDE Events
FC126
80160
0x9CDF Targets
FC101
0x9CF3
Minimum Voltage
10
125
F2
10
80181
0x9CF4
Reset Accumulators
0xFFFFFFFF
x VT
FC142
80183
0x9CF6
Block
0xFFFFFFFF
FC142
80185
0x9CF8
Events
FC126
80186
0x9CF9
Targets
FC101
FC100A
0x9D07
Function
80201
0x9D08
Upper Frequency
500
7000
Hz
F2
6000
80202
0x9D09
Lower Frequency
500
7000
Hz
F2
6000
80203
100000
F10
200
80205
100000
80207
0x9D0E
0xFFFFFFFF
Output Relay
F10
FC198
FC100A
F2
6000
0x9D16
Function
80216
0x9D17
Upper Frequency
500
7000
Hz
80217
0x9D18
Lower Frequency
500
7000
Hz
F2
6000
80218
0x9D19
Time Limit
100000
F10
200
80220
100000
F10
80222
0xFFFFFFFF
FC198
FC100A
F2
6000
0x9D25
Function
80231
0x9D26
Upper Frequency
500
7000
Hz
11-207
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
80232
0x9D27
Lower Frequency
500
7000
F2
6000
80233
0x9D28
Time Limit
100000
F10
200
80235
100000
F10
80237
0xFFFFFFFF
FC198
FC100A
Hz
0x9D34
Function
80246
0x9D35
Upper Frequency
500
7000
Hz
F2
6000
80247
0x9D36
Lower Frequency
500
7000
Hz
F2
6000
80248
0x9D37
Time Limit
100000
F10
200
80250
0x9D39
Time Preset
80252
100000
0xFFFFFFFF
F10
FC198
FC100A
F2
6000
0x9D43
Function
80261
0x9D44
Upper Frequency
500
7000
Hz
80262
0x9D45
Lower Frequency
500
7000
Hz
F2
6000
80263
0x9D46
Time Limit
100000
F10
200
80265
0x9D48
Time Preset
100000
F10
80267
0xFFFFFFFF
FC198
FC100A
0x9D52
Function
80276
0x9D53
Upper Frequency
500
7000
Hz
F2
6000
80277
0x9D54
Lower Frequency
500
7000
Hz
F2
6000
80278
0x9D55
Time Limit
100000
F10
200
80280
0x9D57
Time Preset
100000
F10
80282
0x9D59
Output Relay
0xFFFFFFFF
FC198
FC100A
F2
6000
0x9D61
Function
80291
0x9D62
Upper Frequency
500
7000
Hz
80292
0x9D63
Lower Frequency
500
7000
Hz
F2
6000
80293
0x9D64
Time Limit
100000
F10
200
80295
0x9D66
Time Preset
100000
F10
80297
0x9D68
Output Relay
0xFFFFFFFF
FC198
0x9D7F
Function
FC100A
80321
0x9D80
Signal Input
FC102C
80322
0x9D81
K Factor
100
150
F2
110
FC161E
22
F1
450
Y
Y
80323
0x9D82
Overload Curve
16
22
80324
0x9D83
10000
80325
0x9D84
TD Multiplier
60000
F2
100
80326
0x9D85
10000
min
F1
450
80327
0x9D86
10000
min
F1
100
80328
0x9D87
Thermal Reset
0xFFFFFFFF
FC142
80330
0x9D89
Relays
0xFFFFFFFF
FC198
80332
0x9D8B Block
0xFFFFFFFF
FC142
80334
0x9D8D Events
FC126
11-208
min
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
80335
FC101
0x9D8E
Targets
0xFFFFFFFF
FC142
0x800002 2
80352
0x9D9F
FC126
80354
0x9DA1 Events
FC126
80355
0x9DA2 Targets
FC101
DGA Trigger
0x9E33
Function
FC100A
Y Y Y Y
80501
0x9E34
Pickup Delay
6000000
F13
10000
Y Y Y Y
80503
0x9E36
Dropout Delay
6000000
F13
Y Y Y Y
80505
0x9E38
FC126
Y Y Y Y
80506
0x9E39
0xFFFFFFFF
FC142
Y Y Y Y
80508
0x9E3B
Block
0xFFFFFFFF
FC142
Y Y Y Y
80510
0x9E3D
Relays
0xFFFFFFFF
FC198
Y Y Y Y
80512
0x9E3F
Events
FC126
Y Y Y Y
80513
0x9E40
Targets
FC101
Y Y Y Y
Y Y
0x9E45
Function
FC100A
80519
0x9E46
Pickup Delay
6000000
F13
10000
Y Y
80521
0x9E48
Dropout Delay
6000000
F13
Y Y
80523
0x9E4A
FC126
Y Y
80524
0x9E4B
0xFFFFFFFF
FC142
Y Y
80526
0x9E4D
Block
0xFFFFFFFF
FC142
Y Y
80528
0x9E4F
Relays
0xFFFFFFFF
FC198
Y Y
80530
0x9E51
Events
FC126
Y Y
80531
0x9E52
Targets
FC101
Y Y
FC100A
0x9E57
Function
80537
0x9E58
Pickup Delay
6000000
F13
10000
80539
0x9E5A
Dropout Delay
6000000
F13
80541
0x9E5C
FC126
80542
0x9E5D
0xFFFFFFFF
FC142
80544
0x9E5F
Block
0xFFFFFFFF
FC142
80546
0x9E61
Relays
0xFFFFFFFF
FC198
80548
0x9E63
Events
FC126
80549
0x9E64
Targets
FC101
FC100A
Y Y Y Y
0x9E79
Function
80571
0x9E7A
Pickup Delay
6000000
F13
10000
Y Y Y Y
80573
0x9E7C
Dropout Delay
6000000
F13
Y Y Y Y
80575
0x9E7E
FC126
Y Y Y Y
80576
0x9E7F
0xFFFFFFFF
FC142
Y Y Y Y
80578
0x9E81
Block
0xFFFFFFFF
FC142
Y Y Y Y
80580
0x9E83
Relays
0xFFFFFFFF
FC198
Y Y Y Y
80582
0x9E85
Events
FC126
Y Y Y Y
11-209
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
80583
FC101
Y Y Y Y
0x9E86
Targets
0x9E8B
Function
FC100A
Y Y
80589
0x9E8C
Pickup Delay
6000000
F13
10000
Y Y
80591
0x9E8E
Dropout Delay
6000000
F13
Y Y
80593
0x9E90
FC126
Y Y
80594
0x9E91
0xFFFFFFFF
FC142
Y Y
80596
0x9E93
Block
0xFFFFFFFF
FC142
Y Y
80598
0x9E95
Relays
0xFFFFFFFF
FC198
Y Y
80600
0x9E97
Events
FC126
Y Y
80601
0x9E98
Targets
FC101
Y Y
0x9E9D
Function
FC100A
80607
0x9E9E
Pickup Delay
6000000
F13
10000
80609
0x9EA0
Dropout Delay
6000000
F13
80611
0x9EA2
FC126
80612
0x9EA3
0xFFFFFFFF
FC142
80614
0x9EA5
Block
0xFFFFFFFF
FC142
80616
0x9EA7
Relays
0xFFFFFFFF
FC198
80618
0x9EA9
Events
FC126
80619
0x9EAA
Targets
FC101
Y
Y Y Y Y
0x9EBF
Function
FC100A
80641
0x9EC0
Signal Input
FC102A
Y Y
80642
0x9EC1
Initiation
0xFFFFFFFF
FC142
Y Y Y Y
F13
30
Y Y Y Y
1000
Y Y Y Y
80644
0x9EC3
Delay
6000000
80646
0x9EC5
Alarm Level
50000
kA2-cyc F0
80647
0x9EC6
Relays
0xFFFFFFFF
FC198
Y Y Y Y
80649
0x9EC8
Block
0xFFFFFFFF
FC142
Y Y Y Y
80651
0x9ECA
Events
FC126
Y Y Y Y
80652
0x9ECB
Targets
FC101
Y Y Y Y
FC100A
Y Y
0x9ED2
Function
80660
0x9ED3
Signal Input
FC102A
Y Y
80661
0x9ED4
Initiation
0xFFFFFFFF
FC142
Y Y
80663
0x9ED6
Delay
6000000
F13
30
Y Y
kA2-cyc F0
80665
0x9ED8
Alarm Level
50000
1000
Y Y
80666
0x9ED9
Relays
0xFFFFFFFF
FC198
Y Y
80668
0x9EDB Block
0xFFFFFFFF
FC142
Y Y
80670
0x9EDD Events
FC126
Y Y
80671
0x9EDE
FC101
Y Y
Targets
0x9EE5
Function
FC100A
80679
0x9EE6
Signal Input
FC102A
80680
0x9EE7
Initiation
0xFFFFFFFF
FC142
11-210
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
80682
6000000
F13
30
kA2-cyc F0
0x9EE9
Delay
80684
0x9EEB
Alarm Level
50000
1000
80685
0x9EEC
Relays
0xFFFFFFFF
FC198
80687
0x9EEE
Block
0xFFFFFFFF
FC142
80689
0x9EF0
Events
FC126
80690
0x9EF1
Targets
FC101
Breaker 1 Health
80710
0x9F05
Function
FC100A
Y Y Y Y
80711
0x9F06
Mode
FC277
Y Y Y Y
80712
0x9F07
100000
F10
Y Y Y Y
80714
0x9F09
Trip Trigger
0xFFFFFFFF
FC142
Y Y Y Y
80716
0x9F0B
Close Trigger
0xFFFFFFFF
FC142
Y Y Y Y
80718
0x9F0D
Open Status
0xFFFFFFFF
FC142
Y Y Y Y
80720
0x9F0F
Close Status
0xFFFFFFFF
FC142
Y Y Y Y
80722
0x9F11
0xFFFFFFFF
FC142
Y Y Y Y
80724
0x9F13
6000000
F13
50
Y Y Y Y
80726
0x9F15
6000000
F13
50
Y Y Y Y
80728
0x9F17
6000000
F13
100
Y Y Y Y
80730
0x9F19
6000000
F13
100
Y Y Y Y
80732
0x9F1B
6000000
F13
300
Y Y Y Y
80734
0x9F1D
6000000
F13
15000
Y Y Y Y
80736
0x9F1F
6000000
F13
45000
Y Y Y Y
kA2-cyc F10
80738
0x9F21
100000
1000
Y Y Y Y
80740
0x9F23
Alarm Counter
100
F0
Y Y Y Y
80741
0x9F24
Relays
0xFFFFFFFF
FC198
Y Y Y Y
80743
0x9F26
Block
0xFFFFFFFF
FC142
Y Y Y Y
80745
0x9F28
Events
FC126
Y Y Y Y
80746
0x9F29
Targets
FC101
Y Y Y Y
Breaker 2 Health
80753
0x9F30
Function
FC100A
Y Y
80754
0x9F31
Mode
FC277
Y Y
80755
0x9F32
100000
F10
Y Y
80757
0x9F34
Trip Trigger
0xFFFFFFFF
FC142
Y Y
80759
0x9F36
Close Trigger
0xFFFFFFFF
FC142
Y Y
80761
0x9F38
Open Status
0xFFFFFFFF
FC142
Y Y
80763
0x9F3A
Close Status
0xFFFFFFFF
FC142
Y Y
80765
0x9F3C
0xFFFFFFFF
FC142
Y Y
80767
0x9F3E
6000000
F13
50
Y Y
Y Y
80769
0x9F40
6000000
F13
50
80771
0x9F42
6000000
F13
100
Y Y
80773
0x9F44
6000000
F13
100
Y Y
80775
0x9F46
6000000
F13
300
Y Y
80777
0x9F48
6000000
F13
15000
Y Y
80779
0x9F4A
6000000
F13
45000
Y Y
11-211
Modbus Hex
Description
Address Address
Min
Max
Step Units
80781
100000
0x9F4C
Format
Code
kA2-cyc F10
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
1000
Y Y
80783
0x9F4E
Alarm Counter
100
F0
Y Y
80784
0x9F4F
Relays
0xFFFFFFFF
FC198
Y Y
80786
0x9F51
Block
0xFFFFFFFF
FC142
Y Y
80788
0x9F53
Events
FC126
Y Y
80789
0x9F54
Targets
FC101
Y Y
Breaker 3 Health
80796
0x9F5B
Function
FC100A
80797
0x9F5C
Mode
FC277
80798
0x9F5D
100000
F10
80800
0x9F5F
Trip Trigger
0xFFFFFFFF
FC142
80802
0x9F61
Close Trigger
0xFFFFFFFF
FC142
80804
0x9F63
Open Status
0xFFFFFFFF
FC142
80806
0x9F65
Close Status
0xFFFFFFFF
FC142
80808
0x9F67
0xFFFFFFFF
FC142
80810
0x9F69
6000000
F13
50
80812
0x9F6B
6000000
F13
50
80814
0x9F6D
6000000
F13
100
80816
0x9F6F
6000000
F13
100
80818
0x9F71
6000000
F13
300
80820
0x9F73
6000000
F13
15000
80822
0x9F75
6000000
F13
45000
80824
0x9F77
100000
kA2-cyc F10
1000
80826
0x9F79
Alarm Counter
100
F0
80827
0x9F7A
Relays
0xFFFFFFFF
FC198
80829
0x9F7C
Block
0xFFFFFFFF
FC142
80831
0x9F7E
Events
FC126
80832
0x9F7F
Targets
FC101
FC100A
0x9FEE
Function
80944
0x9FEF
-1200
1199
Hz
F22
40
80945
0x9FF0
-1200
1199
Hz
F22
200
80946
0x9FF1
60000
F2
6000
80947
0x9FF2
50
100
x FLA
F2
70
80948
0x9FF3
100
x FLA
F2
10
80949
0x9FF4
Maximum Current
Unbalance
1000
F1
150
80950
0x9FF5
Motor Voltage
Supervision
1000
F1
500
80951
0x9FF6
Pickup
-60
-12
dB
F20
-40
80952
0x9FF7
Dropout Delay
60000
F2
100
80953
0x9FF8
Block
0xFFFFFFFF
FC142
80955
0x9FFA
Relays
0xFFFFFFFF
FC198
80957
0x9FFC
Events
FC126
80958
0x9FFD
Targets
FC101
11-212
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
Power Factor 1
80983
0xA016
Function
FC100A
Y Y Y Y
80985
0xA018
Switch-In
-99
100
F22
80
Y Y Y Y
80986
0xA019
Switch-Out
-99
100
F22
100
Y Y Y Y
80987
0xA01A
Delay
6000000
F13
50000
Y Y Y Y
80989
0xA01C
Minimum Voltage
125
x VT
F2
30
Y Y Y Y
80990
0xA01D Relays
0xFFFFFFFF
FC198
Y Y Y Y
80992
0xA01F
Block
0xFFFFFFFF
FC142
Y Y Y Y
80994
0xA021
Events
FC126
Y Y Y Y
80995
0xA022
Targets
FC101
Y Y Y Y
Function
FC100A
Y Y Y Y
Power Factor 2
81015
0xA036
81017
0xA038
Switch-In
-99
100
F22
80
Y Y Y Y
81018
0xA039
Switch-Out
-99
100
F22
100
Y Y Y Y
81019
0xA03A
Delay
6000000
F13
50000
Y Y Y Y
81021
0xA03C
Minimum Voltage
125
x VT
F2
30
Y Y Y Y
81022
0xA03D Relays
0xFFFFFFFF
FC198
Y Y Y Y
81024
0xA03F
Block
0xFFFFFFFF
FC142
Y Y Y Y
81026
0xA041
Events
FC126
Y Y Y Y
81027
0xA042
Targets
FC101
Y Y Y Y
Function
FC100A
Y Y Y Y
Current Demand 1
81063
0xA066
81064
0xA067
Signal Input
FC102A
81065
0xA068
Measurement Type
FC254
Y Y Y Y
81066
0xA069
FC255
Y Y Y Y
81067
0xA06A
Time Interval
FC255
Y Y Y Y
81068
0xA06B
Pickup
10
10000
F0
1000
Y Y Y Y
81069
0xA06C
Relays
0xFFFFFFFF
FC198
Y Y Y Y
81071
0xA06E
Block
0xFFFFFFFF
FC142
Y Y Y Y
81073
0xA070
Events
FC126
Y Y Y Y
81074
0xA071
Targets
FC101
Y Y Y Y
Function
FC100A
Current Demand 2
81094
0xA085
81095
0xA086
Signal Input
FC102A
81096
0xA087
Measurement Type
FC254
81097
0xA088
FC255
81098
0xA089
Time Interval
FC255
81099
0xA08A
Pickup
10
10000
F0
1000
81100
0xA08B
Relays
0xFFFFFFFF
FC198
81102
0xA08D Block
0xFFFFFFFF
FC142
81104
0xA08F
Events
FC126
81105
0xA090
Targets
FC101
Function
FC100A
Current Demand 3
81125
0xA0A4
11-213
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
81126
0xA0A5
Signal Input
FC102A
81127
0xA0A6
Measurement Type
FC254
81128
0xA0A7
FC255
81129
0xA0A8
Time Interval
FC255
81130
0xA0A9
Pickup
10
10000
F0
1000
81131
0xA0AA Relays
0xFFFFFFFF
FC198
81133
0xA0AC
Block
0xFFFFFFFF
FC142
81135
0xA0AE
Events
FC126
81136
0xA0AF
Targets
FC101
FC100A
Y Y Y Y
0xA0D4 Function
81175
FC254
Y Y Y Y
81176
FC255
Y Y Y Y
81177
FC255
Y Y Y Y
81178
0xA0D9 Pickup
3000000
F11
10000
Y Y Y Y
81180
0xA0DB Relays
0xFFFFFFFF
FC198
Y Y Y Y
81182
0xA0DD Block
0xFFFFFFFF
FC142
Y Y Y Y
81184
0xA0DF
Events
FC126
Y Y Y Y
81185
0xA0E0
Targets
FC101
Y Y Y Y
kW
0xA106
Function
FC100A
Y Y Y Y
81225
0xA108
Measurement Type
FC254
Y Y Y Y
81226
0xA109
FC255
Y Y Y Y
81227
0xA10A
Time Interval
FC255
Y Y Y Y
81228
0xA10B
Pickup
3000000
F11
10000
Y Y Y Y
81230
0xA10D Relays
0xFFFFFFFF
FC198
Y Y Y Y
81232
0xA10F
Block
0xFFFFFFFF
FC142
Y Y Y Y
kvar
81234
0xA111
Events
FC126
Y Y Y Y
81235
0xA112
Targets
FC101
Y Y Y Y
0xA138
Function
FC100A
Y Y Y Y
81275
0xA13A
Measurement Type
FC254
Y Y Y Y
81276
0xA13B
FC255
Y Y Y Y
81277
0xA13C
Time Interval
FC255
Y Y Y Y
81278
0xA13D Pickup
3000000
F11
10000
Y Y Y Y
81280
0xA13F
Relays
0xFFFFFFFF
kVA
FC198
Y Y Y Y
81282
0xA141
Block
0xFFFFFFFF
FC142
Y Y Y Y
81284
0xA143
Events
FC126
Y Y Y Y
81285
0xA144
Targets
FC101
Y Y Y Y
FC126
Y Y Y Y
F33
10000
Y Y Y Y
FC198A
Y Y Y Y
Pulse Output
81310
0xA15D Function
81311
0xA15E
1000000
81313
0xA160
0xFFFFFFFF
11-214
MWh
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
F33
10000
81315
0xA162
1000000
81317
0xA164
0xFFFFFFFF
81319
0xA166
1000000
81321
0xA168
0xFFFFFFFF
81323
0xA16A
1000000
81325
0xA16C
0xFFFFFFFF
81327
0xA16E
Events
81328
0xA16F
Targets
MWh
Y Y Y Y
FC198A
Y Y Y Y
F33
10000
Y Y Y Y
FC198A
Y Y Y Y
F33
10000
Y Y Y Y
FC198A
Y Y Y Y
FC126
Y Y Y Y
FC101
Y Y Y Y
Mvarh
Mvarh
Digital Counter 1
81360
0xA18F
Function
FC126
81361
0xA190
Name
65535
F60_26
Counter 1 13
Y Y Y Y
Y Y Y Y
65535
Y Y Y Y
81374
0xA19D Units
F60_6
units
81377
0xA1A0
Pre-set
-2147483648 2147483647
F30
Y Y Y Y
81379
0xA1A2
Compare
-2147483648 2147483647
F30
Y Y Y Y
81381
0xA1A4
Up
0xFFFFFFFF
FC142
Y Y Y Y
81383
0xA1A6
Down
0xFFFFFFFF
FC142
Y Y Y Y
81385
0xA1A8
Set to Pre-set
0xFFFFFFFF
FC142
Y Y Y Y
81387
0xA1AA Reset
0xFFFFFFFF
FC142
Y Y Y Y
81389
0xA1AC
Freeze/Reset
0xFFFFFFFF
FC142
Y Y Y Y
81391
0xA1AE
Freeze/Count
0xFFFFFFFF
FC142
Y Y Y Y
81393
0xA1B0
Block
0xFFFFFFFF
FC142
Y Y Y Y
81395
0xA1B2
HI 1 Output Relays
0xFFFFFFFF
FC198
Y Y Y Y
81397
0xA1B4
0xFFFFFFFF
FC198
Y Y Y Y
81399
0xA1B6
LO 1 Output Relays
0xFFFFFFFF
FC198
Y Y Y Y
81401
0xA1B8
Events
FC126
Y Y Y Y
Function
FC126
Y Y Y Y
Digital Counter 2
81402
0xA1B9
81403
0xA1BA Name
65535
F60_26
Counter 2 13
Y Y Y Y
81416
0xA1C7
65535
F60_6
units
Y Y Y Y
81419
0xA1CA Pre-set
F30
Y Y Y Y
Units
-2147483648 2147483647
81421
0xA1CC Compare
-2147483648 2147483647
F30
Y Y Y Y
81423
0xA1CE
0xFFFFFFFF
FC142
Y Y Y Y
81425
0xA1D0 Down
0xFFFFFFFF
FC142
Y Y Y Y
81427
0xFFFFFFFF
FC142
Y Y Y Y
81429
0xA1D4 Reset
0xFFFFFFFF
FC142
Y Y Y Y
81431
0xA1D6 Freeze/Reset
0xFFFFFFFF
FC142
Y Y Y Y
81433
0xA1D8 Freeze/Count
0xFFFFFFFF
FC142
Y Y Y Y
81435
0xA1DA Block
0xFFFFFFFF
FC142
Y Y Y Y
81437
0xFFFFFFFF
FC198
Y Y Y Y
81439
0xFFFFFFFF
FC198
Y Y Y Y
81441
0xA1E0
LO 2 Output Relays
0xFFFFFFFF
FC198
Y Y Y Y
81443
0xA1E2
Events
FC126
Y Y Y Y
Function
FC126
Y Y Y Y
Up
Digital Counter 3
81444
0xA1E3
11-215
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
81445
0xA1E4
Name
65535
F60_26
Counter 3 13
Y Y Y Y
81458
0xA1F1
Units
65535
F60_6
units
Y Y Y Y
81461
0xA1F4
Pre-set
-2147483648 2147483647
F30
Y Y Y Y
81463
0xA1F6
Compare
-2147483648 2147483647
F30
Y Y Y Y
81465
0xA1F8
Up
0xFFFFFFFF
FC142
Y Y Y Y
81467
0xA1FA
Down
0xFFFFFFFF
FC142
Y Y Y Y
81469
0xA1FC
Set to Pre-set
0xFFFFFFFF
FC142
Y Y Y Y
81471
0xA1FE
Reset
0xFFFFFFFF
FC142
Y Y Y Y
81473
0xA200
Freeze/Reset
0xFFFFFFFF
FC142
Y Y Y Y
81475
0xA202
Freeze/Count
0xFFFFFFFF
FC142
Y Y Y Y
81477
0xA204
Block
0xFFFFFFFF
FC142
Y Y Y Y
81479
0xA206
HI 3 Output Relays
0xFFFFFFFF
FC198
Y Y Y Y
81481
0xA208
0xFFFFFFFF
FC198
Y Y Y Y
81483
0xA20A
LO 3 Output Relays
0xFFFFFFFF
FC198
Y Y Y Y
81485
0xA20C
Events
FC126
Y Y Y Y
FC126
Y Y Y Y
Digital Counter 4
81486
0xA20D Function
81487
0xA20E
Name
65535
F60_26
Counter 4 13
Y Y Y Y
81500
0xA21B
Units
65535
F60_6
units
Y Y Y Y
81503
0xA21E
Pre-set
-2147483648 2147483647
F30
Y Y Y Y
81505
0xA220
Compare
-2147483648 2147483647
F30
Y Y Y Y
81507
0xA222
Up
0xFFFFFFFF
FC142
Y Y Y Y
81509
0xA224
Down
0xFFFFFFFF
FC142
Y Y Y Y
81511
0xA226
Set to Pre-set
0xFFFFFFFF
FC142
Y Y Y Y
81513
0xA228
Reset
0xFFFFFFFF
FC142
Y Y Y Y
81515
0xA22A
Freeze/Reset
0xFFFFFFFF
FC142
Y Y Y Y
81517
0xA22C
Freeze/Count
0xFFFFFFFF
FC142
Y Y Y Y
81519
0xA22E
Block
0xFFFFFFFF
FC142
Y Y Y Y
81521
0xA230
HI 4 Output Relays
0xFFFFFFFF
FC198
Y Y Y Y
81523
0xA232
0xFFFFFFFF
FC198
Y Y Y Y
81525
0xA234
LO 4 Output Relays
0xFFFFFFFF
FC198
Y Y Y Y
81527
0xA236
Events
FC126
Y Y Y Y
Digital Counter 5
81528
0xA237
Function
FC126
81529
0xA238
Name
65535
F60_26
Counter 5 13
Y Y Y Y
81542
0xA245
Units
65535
F60_6
units
Y Y Y Y
Y Y Y Y
81545
0xA248
Pre-set
-2147483648 2147483647
F30
Y Y Y Y
81547
0xA24A
Compare
-2147483648 2147483647
F30
Y Y Y Y
81549
0xA24C
Up
0xFFFFFFFF
FC142
Y Y Y Y
81551
0xA24E
Down
0xFFFFFFFF
FC142
Y Y Y Y
81553
0xA250
Set to Pre-set
0xFFFFFFFF
FC142
Y Y Y Y
81555
0xA252
Reset
0xFFFFFFFF
FC142
Y Y Y Y
81557
0xA254
Freeze/Reset
0xFFFFFFFF
FC142
Y Y Y Y
81559
0xA256
Freeze/Count
0xFFFFFFFF
FC142
Y Y Y Y
81561
0xA258
Block
0xFFFFFFFF
FC142
Y Y Y Y
11-216
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
81563
0xA25A
HI 5 Output Relays
0xFFFFFFFF
FC198
Y Y Y Y
81565
0xA25C
0xFFFFFFFF
FC198
Y Y Y Y
81567
0xA25E
LO 5 Output Relays
0xFFFFFFFF
FC198
Y Y Y Y
81569
0xA260
Events
FC126
Y Y Y Y
FC126
Y Y Y Y
Digital Counter 6
81570
0xA261
Function
81571
0xA262
Name
65535
F60_26
Counter 6 13
Y Y Y Y
81584
0xA26F
Units
65535
F60_6
units
Y Y Y Y
81587
0xA272
Pre-set
-2147483648 2147483647
F30
Y Y Y Y
81589
0xA274
Compare
-2147483648 2147483647
F30
Y Y Y Y
81591
0xA276
Up
0xFFFFFFFF
FC142
Y Y Y Y
81593
0xA278
Down
0xFFFFFFFF
FC142
Y Y Y Y
81595
0xA27A
Set to Pre-set
0xFFFFFFFF
FC142
Y Y Y Y
81597
0xA27C
Reset
0xFFFFFFFF
FC142
Y Y Y Y
81599
0xA27E
Freeze/Reset
0xFFFFFFFF
FC142
Y Y Y Y
81601
0xA280
Freeze/Count
0xFFFFFFFF
FC142
Y Y Y Y
81603
0xA282
Block
0xFFFFFFFF
FC142
Y Y Y Y
81605
0xA284
HI 6 Output Relays
0xFFFFFFFF
FC198
Y Y Y Y
81607
0xA286
0xFFFFFFFF
FC198
Y Y Y Y
81609
0xA288
LO 6 Output Relays
0xFFFFFFFF
FC198
Y Y Y Y
81611
0xA28A
Events
FC126
Y Y Y Y
Digital Counter 7
81612
0xA28B
Function
FC126
81613
0xA28C
Name
65535
F60_26
Counter 7 13
Y Y Y Y
81626
0xA299
Units
65535
F60_6
units
Y Y Y Y
Y Y Y Y
81629
0xA29C
Pre-set
-2147483648 2147483647
F30
Y Y Y Y
81631
0xA29E
Compare
-2147483648 2147483647
F30
Y Y Y Y
81633
0xA2A0
Up
FC142
Y Y Y Y
81635
0xA2A2
Down
0xFFFFFFFF
FC142
Y Y Y Y
81637
0xA2A4
Set to Pre-set
0xFFFFFFFF
FC142
Y Y Y Y
0xFFFFFFFF
81639
0xA2A6
Reset
0xFFFFFFFF
FC142
Y Y Y Y
81641
0xA2A8
Freeze/Reset
0xFFFFFFFF
FC142
Y Y Y Y
81643
0xA2AA Freeze/Count
0xFFFFFFFF
FC142
Y Y Y Y
81645
0xA2AC
Block
0xFFFFFFFF
FC142
Y Y Y Y
81647
0xA2AE
HI 7 Output Relays
0xFFFFFFFF
FC198
Y Y Y Y
81649
0xA2B0
0xFFFFFFFF
FC198
Y Y Y Y
81651
0xA2B2
LO 7 Output Relays
0xFFFFFFFF
FC198
Y Y Y Y
81653
0xA2B4
Events
FC126
Y Y Y Y
Digital Counter 8
81654
0xA2B5
Function
FC126
81655
0xA2B6
Name
65535
F60_26
Counter 8 13
Y Y Y Y
Y Y Y Y
65535
Y Y Y Y
81668
0xA2C3
Units
F60_6
units
81671
0xA2C6
Pre-set
-2147483648 2147483647
F30
Y Y Y Y
81673
0xA2C8
Compare
-2147483648 2147483647
F30
Y Y Y Y
81675
0xA2CA Up
FC142
Y Y Y Y
0xFFFFFFFF
11-217
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
81677
0xA2CC Down
0xFFFFFFFF
FC142
81679
0xA2CE
0xFFFFFFFF
FC142
Y Y Y Y
81681
0xA2D0 Reset
0xFFFFFFFF
FC142
Y Y Y Y
81683
0xA2D2 Freeze/Reset
0xFFFFFFFF
FC142
Y Y Y Y
81685
0xA2D4 Freeze/Count
0xFFFFFFFF
FC142
Y Y Y Y
81687
0xA2D6 Block
0xFFFFFFFF
FC142
Y Y Y Y
81689
0xFFFFFFFF
FC198
Y Y Y Y
81691
0xFFFFFFFF
FC198
Y Y Y Y
81693
0xFFFFFFFF
FC198
Y Y Y Y
81695
0xA2DE Events
FC126
Y Y Y Y
FC126
Y Y Y Y
Set to Pre-set
Y Y Y Y
Digital Counter 9
81696
0xA2DF
Function
81697
0xA2E0
Name
65535
F60_26
Counter 9 13
Y Y Y Y
81710
0xA2ED Units
65535
F60_6
units
Y Y Y Y
81713
0xA2F0
Pre-set
-2147483648 2147483647
F30
Y Y Y Y
81715
0xA2F2
Compare
-2147483648 2147483647
F30
Y Y Y Y
81717
0xA2F4
Up
0xFFFFFFFF
FC142
Y Y Y Y
81719
0xA2F6
Down
0xFFFFFFFF
FC142
Y Y Y Y
81721
0xA2F8
Set to Pre-set
0xFFFFFFFF
FC142
Y Y Y Y
81723
0xA2FA
Reset
0xFFFFFFFF
FC142
Y Y Y Y
81725
0xA2FC
Freeze/Reset
0xFFFFFFFF
FC142
Y Y Y Y
81727
0xA2FE
Freeze/Count
0xFFFFFFFF
FC142
Y Y Y Y
81729
0xA300
Block
0xFFFFFFFF
FC142
Y Y Y Y
81731
0xA302
HI 9 Output Relays
0xFFFFFFFF
FC198
Y Y Y Y
81733
0xA304
0xFFFFFFFF
FC198
Y Y Y Y
81735
0xA306
LO 9 Output Relays
0xFFFFFFFF
FC198
Y Y Y Y
81737
0xA308
Events
FC126
Y Y Y Y
Digital Counter 10
81738
0xA309
Function
FC126
Y Y Y Y
81739
0xA30A
Name
65535
F60_26
Counter
10
13
Y Y Y Y
65535
Y Y Y Y
81752
0xA317
Units
F60_6
units
81755
0xA31A
Pre-set
-2147483648 2147483647
F30
Y Y Y Y
81757
0xA31C
Compare
-2147483648 2147483647
F30
Y Y Y Y
81759
0xA31E
Up
0xFFFFFFFF
FC142
Y Y Y Y
81761
0xA320
Down
0xFFFFFFFF
FC142
Y Y Y Y
81763
0xA322
Set to Pre-set
0xFFFFFFFF
FC142
Y Y Y Y
81765
0xA324
Reset
0xFFFFFFFF
FC142
Y Y Y Y
81767
0xA326
Freeze/Reset
0xFFFFFFFF
FC142
Y Y Y Y
81769
0xA328
Freeze/Count
0xFFFFFFFF
FC142
Y Y Y Y
81771
0xA32A
Block
0xFFFFFFFF
FC142
Y Y Y Y
81773
0xA32C
HI 10 Output Relays
0xFFFFFFFF
FC198
Y Y Y Y
81775
0xA32E
0xFFFFFFFF
FC198
Y Y Y Y
81777
0xA330
LO 10 Output Relays
0xFFFFFFFF
FC198
Y Y Y Y
81779
0xA332
Events
FC126
Y Y Y Y
Digital Counter 11
11-218
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
81780
0xA333
Function
FC126
Y Y Y Y
81781
0xA334
Name
65535
F60_26
Counter
11
13
Y Y Y Y
81794
0xA341
Units
65535
F60_6
units
Y Y Y Y
81797
0xA344
Pre-set
-2147483648 2147483647
F30
Y Y Y Y
81799
0xA346
Compare
-2147483648 2147483647
F30
Y Y Y Y
81801
0xA348
Up
FC142
Y Y Y Y
81803
0xA34A
Down
0xFFFFFFFF
FC142
Y Y Y Y
81805
0xA34C
Set to Pre-set
0xFFFFFFFF
FC142
Y Y Y Y
81807
0xA34E
Reset
0xFFFFFFFF
FC142
Y Y Y Y
81809
0xA350
Freeze/Reset
0xFFFFFFFF
FC142
Y Y Y Y
81811
0xA352
Freeze/Count
0xFFFFFFFF
FC142
Y Y Y Y
81813
0xA354
Block
0xFFFFFFFF
FC142
Y Y Y Y
81815
0xA356
HI 11 Output Relays
0xFFFFFFFF
FC198
Y Y Y Y
81817
0xA358
0xFFFFFFFF
FC198
Y Y Y Y
0xFFFFFFFF
81819
0xA35A
LO 11 Output Relays
0xFFFFFFFF
FC198
Y Y Y Y
81821
0xA35C
Events
FC126
Y Y Y Y
Digital Counter 12
81822
0xA35D Function
FC126
Y Y Y Y
81823
0xA35E
65535
F60_26
Counter
12
13
Y Y Y Y
65535
Y Y Y Y
Name
81836
0xA36B
Units
F60_6
units
81839
0xA36E
Pre-set
-2147483648 2147483647
F30
Y Y Y Y
81841
0xA370
Compare
-2147483648 2147483647
F30
Y Y Y Y
81843
0xA372
Up
0xFFFFFFFF
FC142
Y Y Y Y
81845
0xA374
Down
0xFFFFFFFF
FC142
Y Y Y Y
81847
0xA376
Set to Pre-set
0xFFFFFFFF
FC142
Y Y Y Y
81849
0xA378
Reset
0xFFFFFFFF
FC142
Y Y Y Y
81851
0xA37A
Freeze/Reset
0xFFFFFFFF
FC142
Y Y Y Y
81853
0xA37C
Freeze/Count
0xFFFFFFFF
FC142
Y Y Y Y
81855
0xA37E
Block
0xFFFFFFFF
FC142
Y Y Y Y
81857
0xA380
HI 12 Output Relays
0xFFFFFFFF
FC198
Y Y Y Y
81859
0xA382
0xFFFFFFFF
FC198
Y Y Y Y
81861
0xA384
LO 12 Output Relays
0xFFFFFFFF
FC198
Y Y Y Y
81863
0xA386
Events
FC126
Y Y Y Y
Digital Counter 13
81864
0xA387
Function
FC126
Y Y Y Y
81865
0xA388
Name
65535
F60_26
Counter
13
13
Y Y Y Y
81878
0xA395
Units
65535
F60_6
units
Y Y Y Y
81881
0xA398
Pre-set
-2147483648 2147483647
F30
Y Y Y Y
81883
0xA39A
Compare
-2147483648 2147483647
F30
Y Y Y Y
81885
0xA39C
Up
FC142
Y Y Y Y
81887
0xA39E
Down
0xFFFFFFFF
FC142
Y Y Y Y
81889
0xA3A0
Set to Pre-set
0xFFFFFFFF
FC142
Y Y Y Y
81891
0xA3A2
Reset
0xFFFFFFFF
FC142
Y Y Y Y
0xFFFFFFFF
11-219
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
81893
0xA3A4
Freeze/Reset
0xFFFFFFFF
FC142
81895
0xA3A6
Freeze/Count
0xFFFFFFFF
FC142
Y Y Y Y
81897
0xA3A8
Block
0xFFFFFFFF
FC142
Y Y Y Y
81899
0xFFFFFFFF
FC198
Y Y Y Y
81901
0xA3AC
0xFFFFFFFF
FC198
Y Y Y Y
81903
0xA3AE
LO 13 Output Relays
0xFFFFFFFF
FC198
Y Y Y Y
81905
0xA3B0
Events
FC126
Y Y Y Y
Y Y Y Y
Digital Counter 14
81906
0xA3B1
Function
FC126
Y Y Y Y
81907
0xA3B2
Name
65535
F60_26
Counter
14
13
Y Y Y Y
81920
0xA3BF
Units
65535
F60_6
units
Y Y Y Y
81923
0xA3C2
Pre-set
-2147483648 2147483647
F30
Y Y Y Y
81925
0xA3C4
Compare
-2147483648 2147483647
F30
Y Y Y Y
81927
0xA3C6
Up
0xFFFFFFFF
FC142
Y Y Y Y
81929
0xA3C8
Down
0xFFFFFFFF
FC142
Y Y Y Y
81931
0xFFFFFFFF
FC142
Y Y Y Y
81933
0xA3CC Reset
0xFFFFFFFF
FC142
Y Y Y Y
81935
0xA3CE
Freeze/Reset
0xFFFFFFFF
FC142
Y Y Y Y
81937
0xA3D0 Freeze/Count
0xFFFFFFFF
FC142
Y Y Y Y
Y Y Y Y
81939
0xA3D2 Block
0xFFFFFFFF
FC142
81941
0xFFFFFFFF
FC198
Y Y Y Y
81943
0xFFFFFFFF
FC198
Y Y Y Y
81945
0xFFFFFFFF
FC198
Y Y Y Y
81947
0xA3DA Events
FC126
Y Y Y Y
Digital Counter 15
81948
0xA3DB Function
FC126
Y Y Y Y
81949
0xA3DC Name
65535
F60_26
Counter
15
13
Y Y Y Y
65535
81962
0xA3E9
Units
F60_6
units
Y Y Y Y
81965
0xA3EC
Pre-set
-2147483648 2147483647
F30
Y Y Y Y
81967
0xA3EE
Compare
-2147483648 2147483647
F30
Y Y Y Y
81969
0xA3F0
Up
0xFFFFFFFF
FC142
Y Y Y Y
81971
0xA3F2
Down
0xFFFFFFFF
FC142
Y Y Y Y
81973
0xA3F4
Set to Pre-set
0xFFFFFFFF
FC142
Y Y Y Y
81975
0xA3F6
Reset
0xFFFFFFFF
FC142
Y Y Y Y
81977
0xA3F8
Freeze/Reset
0xFFFFFFFF
FC142
Y Y Y Y
81979
0xA3FA
Freeze/Count
0xFFFFFFFF
FC142
Y Y Y Y
81981
0xA3FC
Block
0xFFFFFFFF
FC142
Y Y Y Y
81983
0xA3FE
HI 15 Output Relays
0xFFFFFFFF
FC198
Y Y Y Y
81985
0xA400
0xFFFFFFFF
FC198
Y Y Y Y
81987
0xA402
LO 15 Output Relays
0xFFFFFFFF
FC198
Y Y Y Y
81989
0xA404
Events
FC126
Y Y Y Y
Function
FC126
Y Y Y Y
Digital Counter 16
81990
11-220
0xA405
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
81991
Name
65535
F60_26
Counter
16
13
Y Y Y Y
65535
F60_6
units
Y Y Y Y
F30
Y Y Y Y
0xA406
82004
0xA413
Units
82007
0xA416
Pre-set
-2147483648 2147483647
82009
0xA418
Compare
-2147483648 2147483647
F30
Y Y Y Y
82011
0xA41A
Up
0xFFFFFFFF
FC142
Y Y Y Y
82013
0xA41C
Down
0xFFFFFFFF
FC142
Y Y Y Y
82015
0xA41E
Set to Pre-set
0xFFFFFFFF
FC142
Y Y Y Y
82017
0xA420
Reset
0xFFFFFFFF
FC142
Y Y Y Y
82019
0xA422
Freeze/Reset
0xFFFFFFFF
FC142
Y Y Y Y
82021
0xA424
Freeze/Count
0xFFFFFFFF
FC142
Y Y Y Y
82023
0xA426
Block
0xFFFFFFFF
FC142
Y Y Y Y
82025
0xA428
HI 16 Output Relays
0xFFFFFFFF
FC198
Y Y Y Y
82027
0xA42A
0xFFFFFFFF
FC198
Y Y Y Y
82029
0xA42C
LO 16 Output Relays
0xFFFFFFFF
FC198
Y Y Y Y
82031
0xA42E
Events
FC126
Y Y Y Y
FC100A
Y Y Y Y
Harmonic Detection 1
82050
0xA441
Function
82051
0xA442
Signal Input
FC102A
Y Y
82052
0xA443
Harmonic
FC374
Y Y Y Y
82053
0xA444
Pickup
1000
F1
200
Y Y Y Y
82054
0xA445
Pickup Delay
60000000
F13
Y Y Y Y
82056
0xA447
FC261A
Y Y Y Y
82057
0xA448
100
F2
10
Y Y Y Y
82058
0xA449
Block
0xFFFFFFFF
FC142
Y Y Y Y
82060
0xA44B
Output Relays
0xFFFFFFFF
FC198
Y Y Y Y
82062
0xA44D Events
FC126
Y Y Y Y
82063
0xA44E
FC101
Y Y Y Y
Targets
x CT
Harmonic Detection 2
82074
0xA459
Function
FC100A
Y Y Y Y
82075
0xA45A
Signal Input
FC102A
Y Y
82076
0xA45B
Harmonic
FC374
Y Y Y Y
82077
0xA45C
Pickup
1000
F1
200
Y Y Y Y
82078
60000000
F13
Y Y Y Y
82080
0xA45F
82081
0xA460
100
82082
0xA461
Block
0xFFFFFFFF
82084
0xA463
Output Relays
0xFFFFFFFF
82086
0xA465
Events
82087
0xA466
Targets
FC261A
Y Y Y Y
F2
10
Y Y Y Y
FC142
Y Y Y Y
FC198
Y Y Y Y
FC126
Y Y Y Y
FC101
Y Y Y Y
FC100A
Y Y Y Y
x CT
Harmonic Detection 3
82098
0xA471
Function
82099
0xA472
Signal Input
FC102A
Y Y
82100
0xA473
Harmonic
FC374
Y Y Y Y
82101
0xA474
Pickup
1000
F1
200
Y Y Y Y
82102
0xA475
Pickup Delay
60000000
F13
Y Y Y Y
11-221
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
82104
0xA477
FC261A
82105
0xA478
100
F2
10
Y Y Y Y
82106
0xA479
Block
0xFFFFFFFF
FC142
Y Y Y Y
82108
0xA47B
Output Relays
0xFFFFFFFF
FC198
Y Y Y Y
x CT
Y Y Y Y
82110
0xA47D Events
FC126
Y Y Y Y
82111
0xA47E
FC101
Y Y Y Y
Targets
Harmonic Detection 4
82122
0xA489
Function
FC100A
Y Y Y Y
82123
0xA48A
Signal Input
FC102A
Y Y
82124
0xA48B
Harmonic
FC374
Y Y Y Y
82125
0xA48C
Pickup
1000
F1
200
Y Y Y Y
82126
60000000
F13
Y Y Y Y
82128
0xA48F
82129
0xA490
100
82130
0xA491
Block
0xFFFFFFFF
82132
0xA493
Output Relays
0xFFFFFFFF
82134
0xA495
Events
82135
0xA496
Targets
FC261A
Y Y Y Y
F2
10
Y Y Y Y
FC142
Y Y Y Y
FC198
Y Y Y Y
FC126
Y Y Y Y
FC101
Y Y Y Y
FC100A
Y Y Y Y
x CT
Harmonic Detection 5
82146
0xA4A1
Function
82147
0xA4A2
Signal Input
FC102A
Y Y
82148
0xA4A3
Harmonic
FC374
Y Y Y Y
82149
0xA4A4
Pickup
1000
F1
200
Y Y Y Y
82150
0xA4A5
Pickup Delay
60000000
F13
Y Y Y Y
82152
0xA4A7
FC261A
Y Y Y Y
82153
0xA4A8
100
F2
10
Y Y Y Y
82154
0xA4A9
Block
0xFFFFFFFF
FC142
Y Y Y Y
82156
0xFFFFFFFF
FC198
Y Y Y Y
82158
0xA4AD Events
FC126
Y Y Y Y
82159
0xA4AE
FC101
Y Y Y Y
Targets
x CT
Harmonic Detection 6
82170
0xA4B9
FC100A
Y Y Y Y
82171
Function
FC102A
Y Y
82172
0xA4BB Harmonic
FC374
Y Y Y Y
82173
0xA4BC Pickup
1000
F1
200
Y Y Y Y
82174
60000000
F13
Y Y Y Y
82176
0xA4BF
82177
0xA4C0
100
x CT
FC261A
Y Y Y Y
F2
10
Y Y Y Y
82178
0xA4C1
Block
0xFFFFFFFF
FC142
Y Y Y Y
82180
0xA4C3
Output Relays
0xFFFFFFFF
FC198
Y Y Y Y
82182
0xA4C5
Events
FC126
Y Y Y Y
82183
0xA4C6
Targets
FC101
Y Y Y Y
0xA699
Function
FC100A
82651
0xA69A
FC389
11-222
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
82652
10
10000
ohms
F2
1000
0xA69B
82653
0xA69C
Calculation Window
100
1000
82654
10000
82655
0xA69E
60000
82656
0xA69F
Pickup Stage 2
10000
82657
0xA6A0
60000
82658
0xA6A1
Dropout Delay
60000
82659
0xA6A2
82660
0xA6A3
Block
0xFFFFFFFF
82662
0xA6A5
Relays
0xFFFFFFFF
82664
0xA6A7
Events
82665
0xA6A8
Targets
F3
500
F3
100
F2
F3
600
F2
100
F2
FC126B
FC142
FC198
FC126
FC101
0xF1F2
0xFFFFFFFF
FC300
Y Y Y Y
101941
0xF1F4
0xFFFFFFFF
FC301
Y Y Y Y
Y Y Y Y
Information
102111
0xF29E
PSU Serial #
65535
F60_14
PCBSerial1 7
102118
0xF2A5
CAN1 Serial #
65535
F60_14
PCBSerial2 7
Y Y Y Y
102125
0xF2AC
CAN2 Serial #
65535
F60_14
PCBSerial3 7
Y Y Y Y
102132
0xF2B3
CPU Serial #
65535
F60_14
PCBSerial4 7
Y Y Y Y
102139
0xF2BA
COMM Serial #
65535
F60_14
PCBSerial5 7
Y Y Y Y
102146
0xF2C1
IO_1 Serial #
65535
F60_14
PCBSerial6 7
Y Y Y Y
102153
0xF2C8
IO_2 Serial #
65535
F60_14
PCBSerial7 7
Y Y Y Y
102160
0xF2CF
IO_3 Serial #
65535
F60_14
PCBSerial8 7
Y Y Y Y
102167
0xF2D6
AN_1 Serial #
65535
F60_14
PCBSerial9 7
Y Y Y Y
102174
65535
F60_14
PCBSerial1 7
0
Y Y Y Y
102181
0xF2E4
MAG_1 Serial #
65535
F60_14
PCBSerial1 7
1
Y Y Y Y
102188
0xF2EB
MAG_2 Serial #
65535
F60_14
PCBSerial1 7
2
Y Y Y Y
102195
0xF2F2
FP Serial #
65535
F60_14
PCBSerial1 7
3
Y Y Y Y
FC132
0xFFFF
Y Y Y Y
F0
Y Y Y Y
FC252
Y Y Y Y
Factory Settings
102240
0xF31F
0xFFFF
102241
0xF320
Response Delay
100
102242
0xF321
Login
ms
102243
0xF322
Login Password
65535
F60_22
11
Y Y Y Y
102254
0xF32D
Password
65535
F60_22
11
Y Y Y Y
102265
0xF338
CID Bypass
FC126
Y Y Y Y
Simulation Setup
102550
0xF455
Simulation State
FC165
Y Y Y Y
102552
0xF457
Force Relays
FC126
Y Y Y Y
102554
0xF459
Force LEDs
FC126
Y Y Y Y
30000
F2
Y Y Y Y
Simulation Pre-Fault
102590
0xF47D
11-223
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
102591
30000
F2
0xF47E
Y Y Y Y
102592
0xF47F
30000
F2
Y Y Y Y
102593
0xF480
J2 Prefault Vx Voltage
30000
F2
Y Y Y Y
102594
0xF481
30000
F2
Y Y Y Y
102595
0xF482
30000
F2
Y Y Y Y
102596
0xF483
30000
F2
Y Y Y Y
102597
0xF484
K2 Prefault Vx Voltage
30000
F2
Y Y Y Y
102598
0xF485
-3599
F21
Y Y Y Y
102599
0xF486
-3599
F21
Y Y Y Y
102600
0xF487
-3599
F21
Y Y Y Y
102601
0xF488
-3599
F21
Y Y Y Y
102602
0xF489
-3599
F21
Y Y Y Y
102603
0xF48A
-3599
F21
Y Y Y Y
102604
0xF48B
-3599
F21
Y Y Y Y
102605
0xF48C
-3599
F21
Y Y Y Y
102608
0xF48F
J1 Prefault Phase Ia
46000
x CT
F3
Y Y Y Y
102609
0xF490
J1 Prefault Phase Ib
46000
x CT
F3
Y Y Y Y
102610
0xF491
J1 Prefault Phase Ic
46000
x CT
F3
Y Y Y Y
102611
0xF492
J1 Prefault Phase Ig
46000
x CT
F3
Y Y Y Y
102612
0xF493
K1 Prefault Phase Ia
46000
x CT
F3
Y Y Y Y
102613
0xF494
K1 Prefault Phase Ib
46000
x CT
F3
Y Y Y Y
102614
0xF495
K1 Prefault Phase Ic
46000
x CT
F3
Y Y Y Y
102615
0xF496
K1 Prefault Phase Ig
46000
x CT
F3
Y Y Y Y
102616
0xF497
K2 Prefault Phase Ia
46000
x CT
F3
Y Y Y Y
102617
0xF498
K2 Prefault Phase Ib
46000
x CT
F3
Y Y Y Y
102618
0xF499
K2 Prefault Phase Ic
46000
x CT
F3
Y Y Y Y
102619
0xF49A
K2 Prefault Phase Ig
46000
x CT
F3
Y Y Y Y
102620
0xF49B
J1 Prefault Ia Angle
-3599
F21
Y Y Y Y
102621
0xF49C
J1 Prefault Ib Angle
-3599
F21
Y Y Y Y
102622
0xF49D
J1 Prefault Ic Angle
-3599
F21
Y Y Y Y
102623
0xF49E
J1 Prefault Ig Angle
-3599
F21
Y Y Y Y
102624
0xF49F
K1 Prefault Ia Angle
-3599
F21
Y Y Y Y
102625
0xF4A0
K1 Prefault Ib Angle
-3599
F21
Y Y Y Y
102626
0xF4A1
K1 Prefault Ic Angle
-3599
F21
Y Y Y Y
102627
0xF4A2
K1 Prefault Ig Angle
-3599
F21
Y Y Y Y
102628
0xF4A3
K2 Prefault Ia Angle
-3599
F21
Y Y Y Y
102629
0xF4A4
K2 Prefault Ib Angle
-3599
F21
Y Y Y Y
102630
0xF4A5
K2 Prefault Ic Angle
-3599
F21
Y Y Y Y
102631
0xF4A6
K2 Prefault Ig Angle
-3599
F21
Y Y Y Y
Simulation Fault
102645
0xF4B4
30000
F2
Y Y Y Y
102646
0xF4B5
30000
F2
Y Y Y Y
102647
0xF4B6
30000
F2
Y Y Y Y
102648
0xF4B7
30000
F2
Y Y Y Y
102649
0xF4B8
30000
F2
Y Y Y Y
11-224
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
102650
0xF4B9
30000
F2
102651
0xF4BA
30000
F2
Y Y Y Y
102652
0xF4BB
30000
F2
Y Y Y Y
102653
0xF4BC
-3599
F21
Y Y Y Y
102654
0xF4BD
-3599
F21
Y Y Y Y
102655
0xF4BE
-3599
F21
Y Y Y Y
102656
0xF4BF
-3599
F21
Y Y Y Y
102657
0xF4C0
-3599
F21
Y Y Y Y
102658
0xF4C1
-3599
F21
Y Y Y Y
Y Y Y Y
102659
0xF4C2
-3599
F21
Y Y Y Y
102660
0xF4C3
-3599
F21
Y Y Y Y
102663
0xF4C6
J1 Fault Phase Ia
46000
x CT
F3
Y Y Y Y
102664
0xF4C7
J1 Fault Phase Ib
46000
x CT
F3
Y Y Y Y
102665
0xF4C8
J1 Fault Phase Ic
46000
x CT
F3
Y Y Y Y
102666
0xF4C9
J1 Fault Phase Ig
46000
x CT
F3
Y Y Y Y
102667
0xF4CA
K1 Fault Phase Ia
46000
x CT
F3
Y Y Y Y
102668
0xF4CB
K1 Fault Phase Ib
46000
x CT
F3
Y Y Y Y
102669
0xF4CC
K1 Fault Phase Ic
46000
x CT
F3
Y Y Y Y
102670
46000
x CT
F3
Y Y Y Y
102671
0xF4CE
K2 Fault Phase Ia
46000
x CT
F3
Y Y Y Y
102672
0xF4CF
K2 Fault Phase Ib
46000
x CT
F3
Y Y Y Y
102673
0xF4D0
K2 Fault Phase Ic
46000
x CT
F3
Y Y Y Y
102674
0xF4D1
K2 Fault Phase Ig
46000
x CT
F3
Y Y Y Y
102675
0xF4D2
J1 Fault Ia Angle
-3599
F21
Y Y Y Y
102676
0xF4D3
J1 Fault Ib Angle
-3599
F21
Y Y Y Y
102677
0xF4D4
J1 Fault Ic Angle
-3599
F21
Y Y Y Y
102678
0xF4D5
J1 Fault Ig Angle
-3599
F21
Y Y Y Y
102679
0xF4D6
K1 Fault Ia Angle
-3599
F21
Y Y Y Y
102680
0xF4D7
K1 Fault Ib Angle
-3599
F21
Y Y Y Y
102681
0xF4D8
K1 Fault Ic Angle
-3599
F21
Y Y Y Y
102682
0xF4D9
K1 Fault Ig Angle
-3599
F21
Y Y Y Y
102683
0xF4DA
K2 Fault Ia Angle
-3599
F21
Y Y Y Y
102684
0xF4DB
K2 Fault Ib Angle
-3599
F21
Y Y Y Y
102685
0xF4DC
K2 Fault Ic Angle
-3599
F21
Y Y Y Y
102686
-3599
F21
Y Y Y Y
Simulation Post-Fault
102700
0xF4EB
30000
F2
Y Y Y Y
102701
0xF4EC
30000
F2
Y Y Y Y
102702
0xF4ED
30000
F2
Y Y Y Y
102703
0xF4EE
J2 Postfault Vx Voltage
30000
F2
Y Y Y Y
102704
0xF4EF
30000
F2
Y Y Y Y
102705
0xF4F0
30000
F2
Y Y Y Y
102706
0xF4F1
30000
F2
Y Y Y Y
102707
0xF4F2
K2 Postfault Vx Voltage
30000
F2
Y Y Y Y
102708
0xF4F3
-3599
F21
Y Y Y Y
11-225
FORMAT CODES
Modbus Hex
Description
Address Address
Min
Max
Step Units
Format
Code
Factory
Default
Size in 8 8 8 8
Words 5 6 8 4
0 9 9 5
102709
0xF4F4
-3599
F21
102710
0xF4F5
-3599
F21
Y Y Y Y
102711
0xF4F6
-3599
F21
Y Y Y Y
102712
0xF4F7
-3599
F21
Y Y Y Y
102713
0xF4F8
-3599
F21
Y Y Y Y
102714
0xF4F9
-3599
F21
Y Y Y Y
102715
0xF4FA
-3599
F21
Y Y Y Y
102718
0xF4FD
J1 Postfault Phase Ia
46000
x CT
F3
Y Y Y Y
102719
0xF4FE
J1 Postfault Phase Ib
46000
x CT
F3
Y Y Y Y
102720
0xF4FF
J1 Postfault Phase Ic
46000
x CT
F3
Y Y Y Y
102721
0xF500
J1 Postfault Phase Ig
46000
x CT
F3
Y Y Y Y
102722
0xF501
K1 Postfault Phase Ia
46000
x CT
F3
Y Y Y Y
102723
0xF502
K1 Postfault Phase Ib
46000
x CT
F3
Y Y Y Y
102724
0xF503
K1 Postfault Phase Ic
46000
x CT
F3
Y Y Y Y
102725
0xF504
K1 Postfault Phase Ig
46000
x CT
F3
Y Y Y Y
102726
0xF505
K2 Postfault Phase Ia
46000
x CT
F3
Y Y Y Y
102727
0xF506
K2 Postfault Phase Ib
46000
x CT
F3
Y Y Y Y
102728
0xF507
K2 Postfault Phase Ic
46000
x CT
F3
Y Y Y Y
102729
0xF508
K2 Postfault Phase Ig
46000
x CT
F3
Y Y Y Y
102730
0xF509
J1 Postfault Ia Angle
-3599
F21
Y Y Y Y
102731
0xF50A
J1 Postfault Ib Angle
-3599
F21
Y Y Y Y
102732
0xF50B
J1 Postfault Ic Angle
-3599
F21
Y Y Y Y
Y Y Y Y
102733
0xF50C
J1 Postfault Ig Angle
-3599
F21
Y Y Y Y
102734
0xF50D
K1 Postfault Ia Angle
-3599
F21
Y Y Y Y
102735
0xF50E
K1 Postfault Ib Angle
-3599
F21
Y Y Y Y
102736
0xF50F
K1 Postfault Ic Angle
-3599
F21
Y Y Y Y
102737
0xF510
K1 Postfault Ig Angle
-3599
F21
Y Y Y Y
102738
0xF511
K2 Postfault Ia Angle
-3599
F21
Y Y Y Y
102739
0xF512
K2 Postfault Ib Angle
-3599
F21
Y Y Y Y
102740
0xF513
K2 Postfault Ic Angle
-3599
F21
Y Y Y Y
102741
0xF514
K2 Postfault Ig Angle
-3599
F21
Y Y Y Y
0xFFFFFFFF
FC198
Y Y Y Y
0xF591
Contact Outputs
Format Codes
Numeric Format Codes (F0 through F71) apply to all relay models.
Enumerated Format Codes (FC100 onwards) have the applicable relays marked in the
relay model columns on the right.
Element Status Format Codes (FE001 onwards) contain values that should be masked
with 0x01FF to match the bit field values shown.
Code
Type
Definition
F0
unsigned 16 bits
Unsigned Value
11-226
FORMAT CODES
Code
Type
Definition
F0
unsigned 16 bits
Unsigned Value
unsigned 16 bits
unsigned 16 bits
unsigned 16 bits
unsigned 16 bits
unsigned 16 bits
unsigned 32 bits
1st 16 bits
2nd 16 bits
unsigned 32 bits
1st 16 bits
2nd 16 bits
unsigned 32 bits
1st 16 bits
2nd 16 bits
unsigned 32 bits
1st 16 bits
2nd 16 bits
unsigned 32 bits
1st 16 bits
2nd 16 bits
signed 16 bits
signed 16 bits
signed 16 bits
signed 16 bits
11-227
FORMAT CODES
Code
Type
Definition
When "Setpoints\Device\Installation\Temperature
Display = Celsius
When "Setpoints\Device\Installation\Temperature
Display = Fahrenheit
signed 16 bits
signed 16 bits
signed 16 bits
signed 32 bits
1st 16 bits
2nd 16 bits
signed 32 bits
1st 16 bits
2nd 16 bits
signed 32 bits
1st 16 bits
2nd 16 bits
signed 32 bits
1st 16 bits
2nd 16 bits
unsigned 32 bits
unsigned 32 bits
unsigned 32 bits
unsigned 32 bits
Date MM/DD/YYYY
F54
unsigned 32 bits
Time HH:MM:SS:hh
F55
unsigned 32 bits
Time HH:MM
F60_26
unsigned 16 bits
unsigned 16 bits
unsigned 16 bits
11-228
FORMAT CODES
Code
Type
Definition
F60_16
unsigned 16 bits
unsigned 16 bits
unsigned 16 bits
unsigned 16 bits
unsigned 16 bits
unsigned 16 bits
unsigned 16 bits
MAC Address
F60_12
unsigned 16 bits
unsigned 16 bits
F70
unsigned 32 bits
IP Address
F71
unsigned 32 bits
FC100
unsigned 16 bits
Function Enable
Disabled
Trip
Alarm
Latched Alarm
Configurable
unsigned 16 bits
Disabled
Alarm
Latched Alarm
Configurable
unsigned 16 bits
Function Enable
Disabled
Close
Alarm
Latched Alarm
Grandmaster ID
FC100A
FC100B
FC100D
FC100E
FC101
Configurable
unsigned 16 bits
Function Enable
Disabled
Trip
Configurable
unsigned 16 bits
Function Enable
Disabled
Alarm
Latched Alarm
unsigned 16 bits
Targets
Disabled
11-229
FORMAT CODES
Code
FC102
FC102A
FC102B
Type
Definition
Self-Reset
Latched
unsigned 16 bits
Signal Input
J1
J2
K1
K2
unsigned 16 bits
J1
K1
K2
unsigned 16 bits
FC102C
FC102D
FC103
None
J1
K1
K2
unsigned 16 bits
Signal Input
J1
K1
unsigned 16 bits
Signal Input
J1
K1
K2
unsigned 16 bits
Upper 8 bits
Type
1 = 3VT, 2 = Vx, 3 = CT
Lower 8 bits
FC103A
None
0x12
J2-3VT
0x22
J2-Vx
0x31
J1-CT
unsigned 16 bits
Frequency Reference
J2-3VT
0x22
J2-Vx
unsigned 16 bits
Upper 8 bits
Type
1 = 3VT, 2 = Vx
Lower 8 bits
2 = J2, 4 = K2
0x12
FC103B
Upper 8 bits
Type
1 = 3VT, 2 = Vx
Lower 8 bits
2 = J2, 4 = K2
11-230
0x12
J2-3VT
0x14
K2-3VT
Code
FC103C
FORMAT CODES
Type
Definition
0x22
J2-Vx
0x24
K2-Vx
unsigned 16 bits
Upper 8 bits
1 = 3VT, 2 = Vx
Lower 8 bits
2 = J2, 4 = K2
FC103D
0x12
J2-3VT
0x14
K2-3VT
unsigned 16 bits
Upper 8 bits
Type
1 = 3VT, 2 = Vx
Lower 8 bits
2 = J2, 4 = K2
0x22
J2-Vx
Y
Y
0x24
K2-Vx
unsigned 16 bits
Disabled
0x12
J2-3VT
0x22
J2-Vx
unsigned 16 bits
Ground CT Type
50:00.0
1/5A
unsigned 16 bits
Wye
Delta
unsigned 16 bits
Supply Frequency
60 Hz
50 Hz
25 Hz
FC110
unsigned 16 bits
Hardware Revision
FC114
unsigned 16 bits
Relay Status
FC103E
FC104A
FC106
FC107
FC118
Y
Y
Not Ready
Ready
unsigned 16 bits
None
129
QuickKey 1
130
QuickKey 2
131
QuickKey 3
132
QuickKey 4
133
QuickKey 5
134
USERPushButton1
135
USERPushButton2
136
USERPushButton3
141
No Key Press
142
Nav Up Key
11-231
FORMAT CODES
Code
FC119
FC120
FC121
FC122
FC123
FC124A
FC126A
11-232
Type
Definition
143
144
145
146
Up Key
147
Down Key
148
Enter Key
149
Menu Key
150
Escape Key
151
Reset Key
152
Help Key
unsigned 16 bits
Temperature Units
Celsius
Fahrenheit
unsigned 16 bits
RTD Type
100 Ohm Pt
120 Ohm Ni
100 Ohm Ni
unsigned 16 bits
RTD Application
None
Stator
Bearing
Ambient
Other
unsigned 16 bits
Off
RTD 1
RTD 2
RTD 3
RTD 4
RTD 5
RTD 6
RTD 7
RTD 8
RTD 9
10
RTD 10
11
RTD 11
12
RTD 12
13
RTD 13
unsigned 16 bits
17 Vdc
33 Vdc
84 Vdc
166 Vdc
unsigned 16 bits
Phase Rotation
ABC
ACB
unsigned 16 bits
Off / On Selection
Code
FC126B
FC126
FC131
FC132
FC132A
FC134
FORMAT CODES
Type
Definition
Off
On
unsigned 16 bits
No / Yes Selection
NO
YES
unsigned 16 bits
Disabled
Enabled
unsigned 16 bits
Phase UV Curve
Definite Time
Inverse Time
16
FlexCurve A
17
FlexCurve B
18
FlexCurve C
19
FlexCurve D
unsigned 16 bits
Edit Group
SP Group 1 Active
SP Group 2 Active
SP Group 3 Active
SP Group 4 Active
SP Group 5 Active
SP Group 6 Active
0xFFFF
Active Group
unsigned 16 bits
SP Group 1
SP Group 2
SP Group 3
SP Group 4
SP Group 5
SP Group 6
unsigned 32 bits
Cause of Event
None to Date
Reset
Factory Reload
IRIG-B Failure
11
12
13
14
Comm. Alert 1
15
Comm. Alert 2
16
Comm. Alert 3
11-233
FORMAT CODES
Code
11-234
Type
Definition
19
20
RMIO Mismatch
22
Emergency Restart
23
24
Failed Auth
25
Auth Lockout
26
Firmware Upgd
27
Firmware Lock
28
Setting Chg
29
Setting Lock
30
Login
31
Logoff
32
33
Not Calibrated
34
Prototype Software
35
36
37
39
WiFi Connected
40
WiFi Disconnected
41
42
43
44
45
46
47
48
49
50
51
FP Serial# Invalid
52
53
RTC Error
54
FLASH Error
55
56
57
58
59
60
Version Mismatch
61
SPI Error
62
Slot B IO Error
63
Slot C IO Error
64
65
SelfTestFWUpdate
66
67
SNTP Failure
Code
FORMAT CODES
Type
Definition
68
PTP Failure
69
RTC Failure
70
71
72
73
74
75
76
77
78
79
80
LDR Clear
81
82
83
Duplicate IP Address
84
85
86
87
88
89
90
91
92
DFR Triggered
93
Y
Y
94
DFR Generated
0x200
CI 1 On
0x201
CI 2 On
0x202
CI 3 On
0x203
CI 4 On
0x204
CI 5 On
0x205
CI 6 On
0x206
CI 7 On
0x207
CI 8 On
0x208
CI 9 On
0x209
CI 10 On
0x20A
CI 11 On
0x20B
CI 12 On
0x20C
CI 13 On
0x20D
CI 14 On
0x300
CI 1 Off
0x301
CI 2 Off
0x302
CI 3 Off
0x303
CI 4 Off
0x304
CI 5 Off
0x305
CI 6 Off
11-235
FORMAT CODES
Code
11-236
Type
Definition
0x306
CI 7 Off
0x307
CI 8 Off
0x308
CI 9 Off
0x309
CI 10 Off
0x30A
CI 11 Off
0x30B
CI 12 Off
0x30C
CI 13 Off
0x30D
CI 14 Off
0x400
VI 1 On
0x401
VI 2 On
0x402
VI 3 On
0x403
VI 4 On
0x404
VI 5 On
0x405
VI 6 On
0x406
VI 7 On
0x407
VI 8 On
0x408
VI 9 On
0x409
VI 10 On
0x40A
VI 11 On
0x40B
VI 12 On
0x40C
VI 13 On
0x40D
VI 14 On
0x40E
VI 15 On
0x40F
VI 16 On
0x410
VI 17 On
0x411
VI 18 On
0x412
VI 19 On
0x413
VI 20 On
0x414
VI 21 On
0x415
VI 22 On
0x416
VI 23 On
0x417
VI 24 On
0x418
VI 25 On
0x419
VI 26 On
0x41A
VI 27 On
0x41B
VI 28 On
0x41C
VI 29 On
0x41D
VI 30 On
0x41E
VI 31 On
0x41F
VI 32 On
0x500
VI 1 Off
0x501
VI 2 Off
0x502
VI 3 Off
0x503
VI 4 Off
0x504
VI 5 Off
0x505
VI 6 Off
0x506
VI 7 Off
Code
FORMAT CODES
Type
Definition
0x507
VI 8 Off
0x508
VI 9 Off
0x509
VI 10 Off
0x50A
VI 11 Off
0x50B
VI 12 Off
0x50C
VI 13 Off
0x50D
VI 14 Off
0x50E
VI 15 Off
0x50F
VI 16 Off
0x510
VI 17 Off
0x511
VI 18 Off
0x512
VI 19 Off
0x513
VI 20 Off
0x514
VI 21 Off
0x515
VI 22 Off
0x516
VI 23 Off
0x517
VI 24 Off
0x518
VI 25 Off
0x519
VI 26 Off
0x51A
VI 27 Off
0x51B
VI 28 Off
0x51C
VI 29 Off
0x51D
VI 30 Off
0x51E
VI 31 Off
0x51F
VI 32 Off
0x600
VO 1 On
0x601
VO 2 On
0x602
VO 3 On
0x603
VO 4 On
0x604
VO 5 On
0x605
VO 6 On
0x606
VO 7 On
0x607
VO 8 On
0x608
VO 9 On
0x609
VO 10 On
0x60A
VO 11 On
0x60B
VO 12 On
0x60C
VO 13 On
0x60D
VO 14 On
0x60E
VO 15 On
0x60F
VO 16 On
0x610
VO 17 On
0x611
VO 18 On
0x612
VO 19 On
0x613
VO 20 On
0x614
VO 21 On
0x615
VO 22 On
11-237
FORMAT CODES
Code
11-238
Type
Definition
0x616
VO 23 On
0x617
VO 24 On
0x618
VO 25 On
0x619
VO 26 On
0x61A
VO 27 On
0x61B
VO 28 On
0x61C
VO 29 On
0x61D
VO 30 On
0x61E
VO 31 On
0x61F
VO 32 On
0x700
VO 1 Off
0x701
VO 2 Off
0x702
VO 3 Off
0x703
VO 4 Off
0x704
VO 5 Off
0x705
VO 6 Off
0x706
VO 7 Off
0x707
VO 8 Off
0x708
VO 9 Off
0x709
VO 10 Off
0x70A
VO 11 Off
0x70B
VO 12 Off
0x70C
VO 13 Off
0x70D
VO 14 Off
0x70E
VO 15 Off
0x70F
VO 16 Off
0x710
VO 17 Off
0x711
VO 18 Off
0x712
VO 19 Off
0x713
VO 20 Off
0x714
VO 21 Off
0x715
VO 22 Off
0x716
VO 23 Off
0x717
VO 24 Off
0x718
VO 25 Off
0x719
VO 26 Off
0x71A
VO 27 Off
0x71B
VO 28 Off
0x71C
VO 29 Off
0x71D
VO 30 Off
0x71E
VO 31 Off
0x71F
VO 32 Off
0x800
Rly 1 On
0x801
Rly 2 On
0x802
Rly 3 On
0x803
Rly 4 On
0x807
Rly 8 On
Code
FORMAT CODES
Type
Definition
0x808
Rly 9 On
0x809
Rly 10 On
0x80A
Rly 11 On
0x80B
Rly 12 On
0x80F
Rly 16 On
0x900
Rly 1 Off
0x901
Rly 2 Off
0x902
Rly 3 Off
0x903
Rly 4 Off
0x907
Rly 8 Off
0x908
Rly 9 Off
0x909
Rly 10 Off
0x90A
Rly 11 Off
0x90B
Rly 12 Off
0x90F
Rly 16 Off
0xE00
RI 1 On
0xE01
RI 2 On
0xE02
RI 3 On
0xE03
RI 4 On
0xE04
RI 5 On
0xE05
RI 6 On
0xE06
RI 7 On
0xE07
RI 8 On
0xE08
RI 9 On
0xE09
RI 10 On
0xE0A
RI 11 On
0xE0B
RI 12 On
0xE0C
RI 13 On
0xE0D
RI 14 On
0xE0E
RI 15 On
0xE0F
RI 16 On
0xE10
RI 17 On
0xE11
RI 18 On
0xE12
RI 19 On
0xE13
RI 20 On
0xE14
RI 21 On
0xE15
RI 22 On
0xE16
RI 23 On
0xE17
RI 24 On
0xE18
RI 25 On
0xE19
RI 26 On
0xE1A
RI 27 On
0xE1B
RI 28 On
0xE1C
RI 29 On
0xE1D
RI 30 On
0xE1E
RI 31 On
0xE1F
RI 32 On
11-239
FORMAT CODES
Code
11-240
Type
Definition
0xF00
RI 1 Off
0xF01
RI 2 Off
0xF02
RI 3 Off
0xF03
RI 4 Off
0xF04
RI 5 Off
0xF05
RI 6 Off
0xF06
RI 7 Off
0xF07
RI 8 Off
0xF08
RI 9 Off
0xF09
RI 10 Off
0xF0A
RI 11 Off
0xF0B
RI 12 Off
0xF0C
RI 13 Off
0xF0D
RI 14 Off
0xF0E
RI 15 Off
0xF0F
RI 16 Off
0xF10
RI 17 Off
0xF11
RI 18 Off
0xF12
RI 19 Off
0xF13
RI 20 Off
0xF14
RI 21 Off
0xF15
RI 22 Off
0xF16
RI 23 Off
0xF17
RI 24 Off
0xF18
RI 25 Off
0xF19
RI 26 Off
0xF1A
RI 27 Off
0xF1B
RI 28 Off
0xF1C
RI 29 Off
0xF1D
RI 30 Off
0xF1E
RI 31 Off
0xF1F
RI 32 Off
0x1600
BSG3 - Status 1 On
0x1601
BSG3 - Status 2 On
0x1602
BSG3 - Status 3 On
0x1603
BSG3 - Status 4 On
0x1604
BSG3 - Status 5 On
0x1605
BSG3 - Status 6 On
0x1606
BSG3 - Status 7 On
0x1607
BSG3 - Status 8 On
0x1608
BSG3 - Status 9 On
0x1609
BSG3 - Warning 1 On
0x160A
BSG3 - Warning 2 On
0x160B
BSG3 - Warning 3 On
0x160C
BSG3 - Warning 4 On
0x160D
BSG3 - Warning 5 On
0x160E
BSG3 - Warning 6 On
Code
FORMAT CODES
Type
Definition
0x160F
BSG3 - Warning 7 On
0x1610
BSG3 - Warning 8 On
0x1611
BSG3 - Warning 9 On
0x1612
BSG3 - Alarm 1 On
0x1613
BSG3 - Alarm 2 On
0x1614
BSG3 - Alarm 3 On
0x1615
BSG3 - Alarm 4 On
0x1616
BSG3 - Alarm 5 On
0x1617
BSG3 - Alarm 6 On
0x1618
BSG3 - Alarm 7 On
0x1619
BSG3 - Alarm 8 On
0x161A
BSG3 - Alarm 9 On
0x1700
0x1701
0x1702
0x1703
0x1704
0x1705
0x1706
0x1707
0x1708
0x1709
0x170A
0x170B
0x170C
0x170D
0x170E
0x170F
0x1710
0x1711
0x1712
0x1713
0x1714
0x1715
0x1716
0x1717
0x1718
0x1719
0x171A
0x800002
Any Trip
0x800202
Any Alarm
0x800802
Any Block
0x800A02
Any PKP
0x800C02
Any OP
0x801002
Setpoint Access OP
0x801040
Setting Change
0x801201
11-241
FORMAT CODES
Code
11-242
Type
Definition
0x801204
Authentication Lockout
0x801210
Authentication Fail
0x801220
0x801240
0x801280
0x801300
0x801402
Login
0x801404
Logout
0x801802
In-Service
0x801804
Out-Of-Service
0x801840
Firmware Upgrade
0x801880
Invalid Firmware
0x801A02
Testing ON
0x801C02
0x801E02
0x801E40
IRIG-B Failure
0x801E80
SNTP Failure
0x801F00
PTP Failure
0x802002
PB 1 ON
0x802004
PB 1 OFF
0x802202
PB 2 ON
0x802204
PB 2 OFF
0x802402
PB 3 ON
0x802404
PB 3 OFF
0x802602
Von
0x802604
Voff
0x802802
Von
0x802804
Voff
0x802A02
Von
0x802A04
Voff
0x802C02
Von
0x802C04
Voff
0x802E02
Von
0x802E04
Voff
0x803002
Von
0x803004
Voff
0x803202
Critical Fail OP
0x803402
Comms OK
0x803601
Motor Starting
0x803602
Motor Running
0x803604
Motor Stopped
0x803608
Motor Speed 2
0x803610
Speed2 TR 2-1 OP
0x803620
0x803640
Motor Overload
0x803680
Motor Tripped
0x803700
Emergency Restart
Code
FORMAT CODES
Type
Definition
0x803802
BKR1 Closed
0x803A02
BKR1 Opened
0x803C02
0x803C04
0x803E02
BKR1 Disconnected
0x803E04
BKR1 Connected
0x804002
BKR1 52a CI ON
0x804004
0x804202
BKR1 52b CI ON
0x804204
0x804402
BKR2 Closed
0x804602
BKR2 Opened
0x804802
0x804804
0x804A02
BKR2 Disconnected
0x804A04
BKR2 Connected
0x804C02
BKR2 52a CI ON
0x804C04
0x804E02
BKR2 52b CI ON
0x804E04
0x805002
BKR3 Closed
0x805202
BKR3 Opened
0x805402
0x805404
0x805602
BKR3 Disconnected
0x805604
BKR3 Connected
0x805802
BKR3 52a CI ON
0x805804
0x805A02
BKR3 52b CI ON
0x805A04
0x805C02
Contactor Closed
0x805E02
Contactor Open
0x806002
0x806004
0x806202
Contactor Disconnect
0x806204
Contactor Connected
0x806408
Local Stop
0x806410
Remote Stop
0x806608
Local Start
0x806610
Remote Start
0x808040
VFD Bypassed
0x808080
0x808201
0x808202
Percent Diff OP
0x808208
0x808210
0x808220
11-243
FORMAT CODES
Code
11-244
Type
Definition
0x808240
Percent Diff OP A
0x808280
Percent Diff OP B
0x808300
Percent Diff OP C
0x808401
0x808402
0x808408
0x808410
0x808420
0x808440
0x808480
0x808500
0x808602
0x808640
0x808680
0x808700
0x808802
0x808840
0x808880
0x808900
0x808A02
0x808A40
0x808A80
0x808B00
0x808E02
0x809002
0x809202
0x809208
0x809210
0x809220
0x809240
0x809280
0x809300
0x809402
0x809408
0x809410
0x809420
0x809440
0x809480
0x809500
0x809602
Instant Diff OP
0x809640
Instant Diff OP A
0x809680
Instant Diff OP B
Y
Y
Y
Y
Y
Y
0x809700
Instant Diff OP C
0x809802
Instant Diff OP
0x809840
Instant Diff OP A
0x809880
Instant Diff OP B
0x809900
Instant Diff OP C
Code
FORMAT CODES
Type
Definition
0x809A01
Thermal PKP
0x809A02
Thermal OP
0x80A001
0x80A002
Cur Unbal OP
0x80A040
Single Phasing OP
0x80A201
0x80A202
Mech Jam OP
0x80A601
Undercur PKP
0x80A602
Undercur OP
0x80A801
Overload PKP
0x80A802
Overload OP
0x80AA01
0x80AA02
Short Circuit OP
0x80B001
GndFault PKP
0x80B002
GndFault OP
0x80B202
0x80B402
0x80B801
Underpwr PKP
0x80B802
Underpwr OP
0x80BA01
Overload PKP
0x80BA02
Overload OP
0x80BA08
W1 Overload PKP
0x80BA10
W2 Overload PKP
0x80BA20
W3 Overload PKP
0x80BE01
0x80BE02
Spd2 U/C OP
0x80C001
Ph TOC 1 PKP
0x80C002
Ph TOC 1 OP
0x80C008
Ph TOC 1 PKP A
0x80C010
Ph TOC 1 PKP B
0x80C020
Ph TOC 1 PKP C
0x80C040
Ph TOC 1 OP A
0x80C080
Ph TOC 1 OP B
0x80C100
Ph TOC 1 OP C
0x80C201
Ph TOC 2 PKP
0x80C202
Ph TOC 2 OP
0x80C208
Ph TOC 2 PKP A
0x80C210
Ph TOC 2 PKP B
0x80C220
Ph TOC 2 PKP C
0x80C240
Ph TOC 2 OP A
0x80C280
Ph TOC 2 OP B
0x80C300
Ph TOC 2 OP C
0x80C401
Ph TOC 3 PKP
0x80C402
Ph TOC 3 OP
0x80C408
Ph TOC 3 PKP A
0x80C410
Ph TOC 3 PKP B
0x80C420
Ph TOC 3 PKP C
11-245
FORMAT CODES
Code
11-246
Type
Definition
0x80C440
Ph TOC 3 OP A
0x80C480
Ph TOC 3 OP B
0x80C500
Ph TOC 3 OP C
0x80C601
Ph IOC 1 PKP
Y
Y
0x80C602
Ph IOC 1 OP
0x80C608
Ph IOC 1 PKP A
0x80C610
Ph IOC 1 PKP B
0x80C620
Ph IOC 1 PKP C
0x80C640
Ph IOC 1 OP A
0x80C680
Ph IOC 1 OP B
0x80C700
Ph IOC 1 OP C
0x80C801
Ph IOC 2 PKP
0x80C802
Ph IOC 2 OP
0x80C808
Ph IOC 2 PKP A
0x80C810
Ph IOC 2 PKP B
0x80C820
Ph IOC 2 PKP C
0x80C840
Ph IOC 2 OP A
0x80C880
Ph IOC 2 OP B
0x80C900
Ph IOC 2 OP C
0x80CA01
Ph IOC 3 PKP
0x80CA02
Ph IOC 3 OP
0x80CA08
Ph IOC 3 PKP A
0x80CA10
Ph IOC 3 PKP B
0x80CA20
Ph IOC 3 PKP C
0x80CA40
Ph IOC 3 OP A
0x80CA80
Ph IOC 3 OP B
0x80CB00
Ph IOC 3 OP C
0x80CC01
Ph IOC 4 PKP
0x80CC02
Ph IOC 4 OP
0x80CC08
Ph IOC 4 PKP A
0x80CC10
Ph IOC 4 PKP B
0x80CC20
Ph IOC 4 PKP C
0x80CC40
Ph IOC 4 OP A
0x80CC80
Ph IOC 4 OP B
0x80CD00
Ph IOC 4 OP C
0x80CE01
Ph IOC 5 PKP
0x80CE02
Ph IOC 5 OP
0x80CE08
Ph IOC 5 PKP A
0x80CE10
Ph IOC 5 PKP B
0x80CE20
Ph IOC 5 PKP C
0x80CE40
Ph IOC 5 OP A
0x80CE80
Ph IOC 5 OP B
0x80CF00
Ph IOC 5 OP C
0x80D001
Ph IOC 6 PKP
0x80D002
Ph IOC 6 OP
0x80D008
Ph IOC 6 PKP A
0x80D010
Ph IOC 6 PKP B
Code
FORMAT CODES
Type
Definition
0x80D020
Ph IOC 6 PKP C
0x80D040
Ph IOC 6 OP A
0x80D080
Ph IOC 6 OP B
0x80D100
Ph IOC 6 OP C
0x80D201
Ph IOC 7 PKP
0x80D202
Ph IOC 7 OP
0x80D208
Ph IOC 7 PKP A
0x80D210
Ph IOC 7 PKP B
0x80D220
Ph IOC 7 PKP C
0x80D240
Ph IOC 7 OP A
0x80D280
Ph IOC 7 OP B
0x80D300
Ph IOC 7 OP C
0x80D401
Ph IOC 8 PKP
0x80D402
Ph IOC 8 OP
0x80D408
Ph IOC 8 PKP A
0x80D410
Ph IOC 8 PKP B
0x80D420
Ph IOC 8 PKP C
0x80D440
Ph IOC 8 OP A
0x80D480
Ph IOC 8 OP B
0x80D500
Ph IOC 8 OP C
0x80D602
Ph Dir OC REV
0x80D640
Ph Dir OC REV A
0x80D680
Ph Dir OC REV B
0x80D700
Ph Dir OC REV C
0x80D801
0x80D802
Ntrl TOC 1 OP
0x80DA01
0x80DA02
Ntrl TOC 2 OP
0x80DC01
0x80DC02
Ntrl TOC 3 OP
0x80DE01
0x80DE02
Ntrl IOC 1 OP
0x80E001
0x80E002
Ntrl IOC 2 OP
0x80E201
0x80E202
Ntrl IOC 3 OP
0x80E401
0x80E402
Ntrl IOC 4 OP
0x80E601
Y
Y
Y
0x80E602
Ntrl IOC 5 OP
0x80E801
0x80E802
Ntrl IOC 6 OP
0x80EA08
0x80EA40
0x80EC01
0x80EC02
GND TOC 1 OP
0x80EE01
11-247
FORMAT CODES
Code
11-248
Type
Definition
0x80EE02
GND TOC 2 OP
0x80F001
Y
Y
0x80F002
GND TOC 3 OP
0x80F201
0x80F202
GND IOC 1 OP
0x80F401
0x80F402
GND IOC 2 OP
0x80F601
0x80F602
GND IOC 3 OP
0x80F801
Y
Y
0x80F802
GND IOC 4 OP
0x80FA01
0x80FA02
GND IOC 5 OP
0x80FC01
0x80FC02
GND IOC 6 OP
0x80FE08
0x80FE40
0x810001
Y
Y
0x810002
SGND TOC 1 OP
0x810401
Y
Y
Y
0x810402
SGND IOC 1 OP
0x810808
0x810840
0x810A01
RGF 1 PKP
0x810A02
RGF 1 OP
0x810A08
RGF 1 Superv ON
0x810C01
RGF 2 PKP
0x810C02
RGF 2 OP
0x810C08
RGF 2 Superv ON
0x810E01
RGF 3 PKP
0x810E02
RGF 3 OP
0x810E08
RGF 3 Superv ON
0x811001
0x811002
NegSeq TOC 1 OP
0x811201
0x811202
NegSeq TOC 2 OP
0x811401
0x811402
NegSeq TOC 3 OP
0x811601
0x811602
NegSeq IOC 1 OP
0x811801
0x811802
NegSeq IOC 2 OP
0x811A01
0x811A02
NegSeq IOC 3 OP
0x811C08
0x811C40
0x811E01
Code
FORMAT CODES
Type
Definition
0x811E02
Broken Cond OP
0x812001
0x812002
Load Encro OP
0x812201
Thermal PKP
0x812202
Thermal OP
0x812208
Thermal PKP A
0x812210
Thermal PKP B
0x812220
Thermal PKP C
0x812240
Thermal OP A
0x812280
Thermal OP B
0x812300
Thermal OP C
0x812402
Thermal Alarm
0x812440
Thermal Alarm A
0x812480
Thermal Alarm B
0x812500
Thermal Alarm C
0x812601
0x812602
Phase Rev OP
0x812640
0x812801
Ph UV 1 PKP
0x812802
Ph UV 1 OP
0x812808
Ph UV 1 PKP A
0x812810
Ph UV 1 PKP B
0x812820
Ph UV 1 PKP C
0x812840
Ph UV 1 OP A
0x812880
Ph UV 1 OP B
0x812900
Ph UV 1 OP C
0x812A01
Ph UV 2 PKP
0x812A02
Ph UV 2 OP
0x812A08
Ph UV 2 PKP A
0x812A10
Ph UV 2 PKP B
0x812A20
Ph UV 2 PKP C
0x812A40
Ph UV 2 OP A
0x812A80
Ph UV 2 OP B
0x812B00
Ph UV 2 OP C
0x812C01
Aux UV 1 PKP
0x812C02
Aux UV 1 OP
0x812E01
Aux UV 2 PKP
0x812E02
Aux UV 2 OP
0x813001
Ph OV 1 PKP
0x813002
Ph OV 1 OP
0x813008
Ph OV 1 PKP A
0x813010
Ph OV 1 PKP B
0x813020
Ph OV 1 PKP C
0x813040
Ph OV 1 OP A
0x813080
Ph OV 1 OP B
0x813100
Ph OV 1 OP C
0x813201
Ph OV 2 PKP
11-249
FORMAT CODES
Code
11-250
Type
Definition
0x813202
Ph OV 2 OP
0x813208
Ph OV 2 PKP A
0x813210
Ph OV 2 PKP B
0x813220
Ph OV 2 PKP C
0x813240
Ph OV 2 OP A
0x813280
Ph OV 2 OP B
0x813300
Ph OV 2 OP C
0x813401
Aux OV 1 PKP
0x813402
Aux OV 1 OP
0x813601
Aux OV 2 PKP
0x813602
Aux OV 2 OP
0x813604
Aux OV 2 DPO
0x813801
Ntrl OV 1 PKP
0x813802
Ntrl OV 1 OP
0x813C01
NegSeq OV 1 PKP
0x813C02
NegSeq OV 1 OP
0x813E01
NegSeq OV 2 PKP
0x813E02
NegSeq OV 2 OP
0x814001
V/Hz 1 PKP
0x814002
V/Hz 1 OP
0x814201
V/Hz 2 PKP
0x814202
V/Hz 2 OP
0x814401
DirPwr 1 PKP
0x814402
DirPwr 1 OP
0x814408
0x814410
0x814440
DirPwr 1 Stg1 OP
0x814480
DirPwr 1 Stg2 OP
0x814601
DirPwr 2 PKP
0x814602
DirPwr 2 OP
0x814608
0x814610
0x814640
DirPwr 2 Stg1 OP
0x814680
DirPwr 2 Stg2 OP
0x814801
0x814802
Watt GndFlt 1 OP
0x814C01
Underfreq 1 PKP
0x814C02
Underfreq 1 OP
0x814E01
Underfreq 2 PKP
0x814E02
Underfreq 2 OP
0x815001
Underfreq 3 PKP
0x815002
Underfreq 3 OP
0x815201
Underfreq 4 PKP
0x815202
Underfreq 4 OP
0x815401
Underfreq 5 PKP
0x815402
Underfreq 5 OP
0x815404
Underfreq 5 DPO
Code
FORMAT CODES
Type
Definition
0x815601
Underfreq 6 PKP
0x815602
Underfreq 6 OP
0x815604
Underfreq 6 DPO
0x815801
Overfreq 1 PKP
0x815802
Overfreq 1 OP
0x815A01
Overfreq 2 PKP
0x815A02
Overfreq 2 OP
0x815C01
Overfreq 3 PKP
0x815C02
Overfreq 3 OP
0x815C04
Overfreq 3 DPO
0x815E01
Overfreq 4 PKP
0x815E02
Overfreq 4 OP
0x815E04
Overfreq 4 DPO
0x816001
FreqRate1 PKP
0x816002
FreqRate1 OP
0x816008
FreqRate1 Up PKP
0x816010
0x816040
FreqRate1 Up OP
0x816080
FreqRate1 Dwn OP
0x816201
FreqRate2 PKP
0x816202
FreqRate2 OP
0x816208
FreqRate2 Up PKP
0x816210
0x816240
FreqRate2 Up OP
0x816280
FreqRate2 Dwn OP
0x816401
FreqRate3 PKP
0x816402
FreqRate3 OP
0x816408
FreqRate3 Up PKP
0x816410
0x816440
FreqRate3 Up OP
0x816480
FreqRate3 Dwn OP
0x816601
FreqRate4 PKP
0x816602
FreqRate4 OP
0x816608
FreqRate4 Up PKP
0x816610
0x816640
FreqRate4 Up OP
0x816680
FreqRate4 Dwn OP
0x816801
FreqRate5 PKP
0x816802
FreqRate5 OP
0x816808
FreqRate5 Up PKP
0x816810
0x816840
FreqRate5 Up OP
0x816880
FreqRate5 Dwn OP
0x816A01
FreqRate6 PKP
0x816A02
FreqRate6 OP
0x816A08
FreqRate6 Up PKP
0x816A10
11-251
FORMAT CODES
Code
11-252
Type
Definition
0x816A40
FreqRate6 Up OP
0x816A80
FreqRate6 Dwn OP
0x816C02
Xfmr Energized
0x816C04
Xfmr De-Energized
0x816C08
Not Configured
0x816E08
0x816E10
0x816E20
0x816E40
TC at Min Tap ON
0x816E80
TC at Ntrl Tap ON
0x816F00
TC at Max Tap ON
0x817002
0x817201
0x817202
W1 Hmc Der OP
0x817401
0x817402
W2 Hmc Der OP
0x817601
0x817602
W3 Hmc Der OP
0x817801
Hotst-Spot PKP
0x817802
Hotst-Spot OP
0x817A01
0x817A02
Aging Fctr OP
0x817C01
0x817C02
Xfmr LOL OP
0x817E01
0x817E02
Tap Ch Fail OP
0x818001
0x818002
TripCoil Mon 1 OP
0x818201
0x818202
TripCoil Mon 2 OP
0x818601
0x818602
0x818801
0x818802
0x818C02
BKR1 Arc OP
0x818E02
BKR2 Arc OP
0x819201
0x819202
0x819208
0x819210
0x819220
0x819240
0x819801
0x819808
0x819810
0x819820
0x819840
Code
FORMAT CODES
Type
Definition
0x819880
0x819900
0x819E01
0x819E02
0x81A008
PF 1 Switch-In
0x81A010
PF 1 Switch-Out
0x81A040
PF 1 Switch-In OP
0x81A080
PF 1 Switch-Out OP
0x81A208
PF 2 Switch-In
0x81A210
PF 2 Switch-Out
0x81A240
PF 2 Switch-In OP
0x81A280
PF 2 Switch-Out OP
0x81A401
0x81A408
0x81A410
0x81A420
0x81A601
0x81A608
0x81A610
0x81A620
0x81A801
0x81A808
0x81A810
0x81A820
0x81AA01
0x81AC01
0x81AE01
0x81B008
0x81B010
0x81B020
0x81B040
0x81B208
Counter 1 LO
0x81B210
Counter 1 EQL
0x81B220
Counter 1 HI
0x81B240
Counter 1 at Limit
0x81B408
Counter 2 LO
0x81B410
Counter 2 EQL
0x81B420
Counter 2 HI
0x81B440
Counter 2 at Limit
0x81B608
Counter 3 LO
0x81B610
Counter 3 EQL
0x81B620
Counter 3 HI
0x81B640
Counter 3 at Limit
0x81B808
Counter 4 LO
0x81B810
Counter 4 EQL
0x81B820
Counter 4 HI
0x81B840
Counter 4 at Limit
11-253
FORMAT CODES
Code
11-254
Type
Definition
0x81BA08
Counter 5 LO
0x81BA10
Counter 5 EQL
0x81BA20
Counter 5 HI
0x81BA40
Counter 5 at Limit
0x81BC08
Counter 6 LO
0x81BC10
Counter 6 EQL
0x81BC20
Counter 6 HI
0x81BC40
Counter 6 at Limit
0x81BE08
Counter 7 LO
0x81BE10
Counter 7 EQL
0x81BE20
Counter 7 HI
0x81BE40
Counter 7 at Limit
0x81C008
Counter 8 LO
0x81C010
Counter 8 EQL
0x81C020
Counter 8 HI
0x81C040
Counter 8 at Limit
0x81C208
Counter 9 LO
0x81C210
Counter 9 EQL
0x81C220
Counter 9 HI
0x81C240
Counter 9 at Limit
0x81C408
Counter 10 LO
0x81C410
Counter 10 EQL
0x81C420
Counter 10 HI
0x81C440
Counter 10 at Limit
0x81C608
Counter 11 LO
0x81C610
Counter 11 EQL
0x81C620
Counter 11 HI
0x81C640
Counter 11 at Limit
0x81C808
Counter 12 LO
0x81C810
Counter 12 EQL
0x81C820
Counter 12 HI
0x81C840
Counter 12 at Limit
0x81CA08
Counter 13 LO
0x81CA10
Counter 13 EQL
0x81CA20
Counter 13 HI
0x81CA40
Counter 13 at Limit
0x81CC08
Counter 14 LO
0x81CC10
Counter 14 EQL
0x81CC20
Counter 14 HI
0x81CC40
Counter 14 at Limit
0x81CE08
Counter 15 LO
0x81CE10
Counter 15 EQL
0x81CE20
Counter 15 HI
0x81CE40
Counter 15 at Limit
0x81D008
Counter 16 LO
0x81D010
Counter 16 EQL
0x81D020
Counter 16 HI
Code
FORMAT CODES
Type
Definition
0x81D040
Counter 16 at Limit
0x81D201
0x81D202
Harm Det 1 OP
0x81D401
0x81D402
Harm Det 2 OP
0x81D601
0x81D602
Harm Det 3 OP
0x81D801
0x81D802
Harm Det 4 OP
0x81DA01
0x81DA02
Harm Det 5 OP
0x81DC01
0x81DC02
Harm Det 6 OP
0x81DE02
Start Inhibit
0x81E040
Clear Events
0x81E080
Clear Transient
0x81E100
0x81E202
Group 1 Active
0x81E402
Group 2 Active
0x81E602
Group 3 Active
0x81E802
Group 4 Active
0x81EA02
Group 5 Active
0x81EC02
Group 6 Active
0x81EE01
0x81EE02
Thermal Inhibit OP
0x81F001
Y
Y
0x81F002
0x81F201
0x81F202
0x81F401
0x81F402
Restart Delay OP
0x81F602
0x81F802
0x81FA08
Local Mode ON
0x81FA10
0x81FA40
BKR1 Selected
0x81FA80
BKR2 Selected
0x81FB00
BKR3 Selected
0x81FC08
0x81FC10
0x81FE08
0x81FE10
0x820008
0x820010
0x820208
0x820210
0x820401
Y
Y
11-255
FORMAT CODES
Code
11-256
Type
Definition
0x820402
Close BKR2 OP
0x820408
0x820410
0x820608
0x820610
0x820801
0x820802
Trip Bus 1 OP
0x820A01
0x820A02
Trip Bus 2 OP
0x820C01
0x820C02
Trip Bus 3 OP
0x820E01
0x820E02
Trip Bus 4 OP
0x821001
0x821002
Trip Bus 5 OP
0x821201
0x821202
Trip Bus 6 OP
0x821402
BF1 OP
0x821408
BF1 Retrip
0x821410
BF1 Highset OP
0x821420
BF1 Lowset OP
0x821440
0x821601
BF2 PKP
0x821602
BF2 OP
0x821608
BF2 Retrip
0x821610
BF2 Highset OP
0x821620
BF2 Lowset OP
0x821640
0x821801
BF3 PKP
0x821802
BF3 OP
0x821808
BF3 Retrip
0x821810
BF3 Highset OP
0x821820
BF3 Lowset OP
0x821840
0x821A02
0x821A08
0x821A10
0x821A20
0x821A40
0x821A80
0x821B00
Sync1 OK
0x821E02
0x822001
0x822002
Cold Load 1 OP
0x822401
Ph UV Restore PKP
0x822408
0x822440
Aux UV Restore OP
Code
FORMAT CODES
Type
Definition
0x822480
Ph UV Restore OP
0x822500
UV Restore Init
0x822601
UF Restore PKP
0x822602
UF Restore OP
0x822640
UF Restore Init
0x822801
0x822802
0x822804
0x822808
0x822810
0x822820
0x822840
0x822880
Tie-BKR Conn&Clsd
0x822900
0x822A02
Transfer Initiated
0x822C01
AR1 Disabled
0x822C08
AR1 Enabled
0x822C10
AR1 Initiated
0x822C20
AR1 In Progress
0x822C40
AR1 Close
0x822C80
AR1 Lockout
0x822D00
0x822E08
0x822E10
0x822E20
0x822E40
0x822E80
0x823008
AR1 ShotRdc to 1
0x823010
AR1 ShotRdc to 2
0x823020
AR1 ShotRdc to 3
0x823040
AR1 ShotRdc to LO
0x823208
0x823210
0x823220
AR1 Coordinating
0x823C02
VT Fuse Fail1 OP
0x823C08
VT Fuse1 V Loss
0x824002
NV Latch 1 ON
0x824004
NV Latch 1 OFF
0x824202
NV Latch 2 ON
0x824204
NV Latch 2 OFF
0x824402
NV Latch 3 ON
0x824404
NV Latch 3 OFF
0x824602
NV Latch 4 ON
0x824604
NV Latch 4 OFF
0x824802
NV Latch 5 ON
0x824804
NV Latch 5 OFF
0x824A02
NV Latch 6 ON
11-257
FORMAT CODES
Code
11-258
Type
Definition
0x824A04
NV Latch 6 OFF
0x824C02
NV Latch 7 ON
0x824C04
NV Latch 7 OFF
0x824E02
NV Latch 8 ON
0x824E04
NV Latch 8 OFF
0x825002
NV Latch 9 ON
0x825004
NV Latch 9 OFF
0x825202
NV Latch 10 ON
0x825204
NV Latch 10 OFF
0x825402
NV Latch 11 ON
0x825404
NV Latch 11 OFF
0x825602
NV Latch 12 ON
0x825604
NV Latch 12 OFF
0x825802
NV Latch 13 ON
0x825804
NV Latch 13 OFF
0x825A02
NV Latch 14 ON
0x825A04
NV Latch 14 OFF
0x825C02
NV Latch 15 ON
0x825C04
NV Latch 15 OFF
0x825E02
NV Latch 16 ON
0x825E04
NV Latch 16 OFF
0x826001
FlexEl 1 PKP
0x826002
FlexEl 1 OP
0x826201
FlexEl 2 PKP
0x826202
FlexEl 2 OP
0x826401
FlexEl 3 PKP
0x826402
FlexEl 3 OP
0x826601
FlexEl 4 PKP
0x826602
FlexEl 4 OP
0x826801
FlexEl 5 PKP
0x826802
FlexEl 5 OP
0x826A01
FlexEl 6 PKP
0x826A02
FlexEl 6 OP
0x826C01
FlexEl 7 PKP
0x826C02
FlexEl 7 OP
0x826E01
FlexEl 8 PKP
0x826E02
FlexEl 8 OP
0x827002
Hot RTD
0x827201
RTD 1 PKP
0x827202
RTD 1 OP
0x827240
RTD 1 Open
0x827280
RTD 1 Shorted
0x827401
RTD 2 PKP
0x827402
RTD 2 OP
0x827440
RTD 2 Open
0x827480
RTD 2 Shorted
0x827601
RTD 3 PKP
Code
FORMAT CODES
Type
Definition
0x827602
RTD 3 OP
0x827640
RTD 3 Open
0x827680
RTD 3 Shorted
0x827801
RTD 4 PKP
0x827802
RTD 4 OP
0x827840
RTD 4 Open
0x827880
RTD 4 Shorted
0x827A01
RTD 5 PKP
0x827A02
RTD 5 OP
0x827A40
RTD 5 Open
0x827A80
RTD 5 Shorted
0x827C01
RTD 6 PKP
0x827C02
RTD 6 OP
0x827C40
RTD 6 Open
0x827C80
RTD 6 Shorted
0x827E01
RTD 7 PKP
0x827E02
RTD 7 OP
0x827E40
RTD 7 Open
0x827E80
RTD 7 Shorted
0x828001
RTD 8 PKP
0x828002
RTD 8 OP
0x828040
RTD 8 Open
0x828080
RTD 8 Shorted
0x828201
RTD 9 PKP
0x828202
RTD 9 OP
0x828240
RTD 9 Open
0x828280
RTD 9 Shorted
0x828401
RTD 10 PKP
0x828402
RTD 10 OP
0x828440
RTD 10 Open
0x828480
RTD 10 Shorted
0x828601
RTD 11 PKP
0x828602
RTD 11 OP
0x828640
RTD 11 Open
0x828680
RTD 11 Shorted
0x828801
RTD 12 PKP
0x828802
RTD 12 OP
0x828840
RTD 12 Open
0x828880
RTD 12 Shorted
0x828A01
RTD 13 PKP
0x828A02
RTD 13 OP
0x828A40
RTD 13 Open
0x828A80
RTD 13 Shorted
0x830201
Anlg Ip 1 PKP
Y
Y
0x830202
Anlg Ip 1 OP
0x830401
Anlg Ip 2 PKP
0x830402
Anlg Ip 2 OP
11-259
FORMAT CODES
Code
11-260
Type
Definition
0x830601
Anlg Ip 3 PKP
0x830602
Anlg Ip 3 OP
0x830801
Anlg Ip 4 PKP
0x830802
Anlg Ip 4 OP
0x833402
0x833601
Fast UF 1 PKP
0x833602
Fast UF 1 OP
0x833801
Fast UF 2 PKP
0x833802
Fast UF 2 OP
0x833A01
Fast UF 3 PKP
0x833A02
Fast UF 3 OP
0x833C01
Fast UF 4 PKP
0x833C02
Fast UF 4 OP
0x833E01
Fast UF 5 PKP
0x833E02
Fast UF 5 OP
0x834001
Fast UF 6 PKP
0x834002
Fast UF 6 OP
0x834201
Fast UF 7 PKP
0x834202
Fast UF 7 OP
0x834401
Fast UF 8 PKP
0x834402
Fast UF 8 OP
0x834602
Arc Flash 1 OP
0x834801
AF 1 Light 1 PKP
0x834808
AF 1 Light 2 PKP
0x834810
AF 1 Light 3 PKP
0x834820
AF 1 Light 4 PKP
0x834C01
0x834C08
AF 1 HS Ph IOC PKP A
0x834C10
AF 1 HS Ph IOC PKP B
0x834C20
AF 1 HS Ph IOC PKP C
0x834E02
Arc Flash 1 S1 OP
0x834E40
Arc Flash 1 S2 OP
0x834E80
Arc Flash 1 S3 OP
0x834F00
Arc Flash 1 S4 OP
0x835202
Arc Flash 2 OP
0x835401
AF 2 Light 1 PKP
0x835408
AF 2 Light 2 PKP
0x835410
AF 2 Light 3 PKP
0x835420
AF 2 Light 4 PKP
0x835801
0x835808
AF 2 HS Ph IOC PKP A
0x835810
AF 2 HS Ph IOC PKP B
0x835820
AF 2 HS Ph IOC PKP C
0x835A02
Arc Flash 2 S1 OP
0x835A40
Arc Flash 2 S2 OP
0x835A80
Arc Flash 2 S3 OP
0x835B00
Arc Flash 2 S4 OP
Code
FORMAT CODES
Type
Definition
0x835E02
Arc Flash 3 OP
0x836001
AF 3 Light 1 PKP
0x836008
AF 3 Light 2 PKP
0x836010
AF 3 Light 3 PKP
0x836020
AF 3 Light 4 PKP
0x836401
0x836408
AF 3 HS Ph IOC PKP A
0x836410
AF 3 HS Ph IOC PKP B
0x836420
AF 3 HS Ph IOC PKP C
0x836602
Arc Flash 3 S1 OP
0x836640
Arc Flash 3 S2 OP
0x836680
Arc Flash 3 S3 OP
0x836700
Arc Flash 3 S4 OP
0x836C02
0x836C40
0x836C80
0x836D00
0x837001
Offline
0x837002
Online
0x837008
Tripped
0x837202
Run Hrs OP
0x837401
0x837402
0x837601
0x837602
0x837801
0x837802
0x837A01
0x837A02
0x837C01
0x837C02
0x837E01
0x837E02
0x838001
0x838002
0x838201
Unbal PKP
0x838202
Unbal OP
0x838204
Unbal DPO
0x838601
0x838602
Inadv Energ OP
0x838801
Offline OC PKP
0x838802
Offline OC OP
0x838808
Offline OC PKP A
0x838810
Offline OC PKP B
0x838820
Offline OC PKP C
0x838840
Offline OC OP A
0x838880
Offline OC OP B
11-261
FORMAT CODES
Code
11-262
Type
Definition
0x838900
Offline OC OP C
0x838A01
0x838A02
0x838C01
0x838C02
Seq Shtdn OP
0x838E08
0x838E10
0x838E40
Pos Mvar OP
0x838E80
Neg Mvar OP
0x839201
0x839202
3rd Ntr UV OP
0x839601
0x839602
3rd V Dif OP
0x839A01
0x839A02
LOE Circle 1 OP
0x839C01
0x839C02
LOE Circle 2 OP
0x839E02
OOS OP
0x839E08
0x839E10
0x839E20
0x83A001
Thermal OL PKP
0x83A002
Thermal OL OP
0x83A208
0x83A210
0x83A240
0x83A280
0x83A401
0x83A402
DGA Alarm OP
0x83A608
Device 1 Offline
0xA09602
0xA09640
0xA09680
0xA09700
0xA09802
0xA09840
0xA09880
0xA09900
0xA09C02
Thermal Alarm OP
0xA09E01
0xA09E02
0xA0A401
0xA0A402
Undercur Alarm OP
0xA0A801
0xA0A802
Overload Alm OP
0xA0AE01
0xA0AE02
GndFault Alarm OP
Code
FORMAT CODES
Type
Definition
0xA0B402
0xA0B601
0xA0B602
Underpwr Alarm OP
0xA0BA01
0xA0BA02
Overload Alm OP
0xA0BA08
0xA0BA10
0xA0BA20
0xA0BC01
0xA0BC02
0xA0C401
0xA0C402
Ph TOC 3 Alrm OP
0xA0C408
0xA0C410
0xA0C420
0xA0C440
Ph TOC 3 Alrm OP A
0xA0C480
Ph TOC 3 Alrm OP B
0xA0C500
Ph TOC 3 Alrm OP C
0xA0CA01
0xA0CA02
Ph IOC 3 Alrm OP
0xA0CA08
0xA0CA10
0xA0CA20
0xA0CA40
Ph IOC 3 Alrm OP A
0xA0CA80
Ph IOC 3 Alrm OP B
0xA0CB00
Ph IOC 3 Alrm OP C
0xA0CC01
0xA0CC02
Ph IOC 4 Alrm OP
0xA0CC08
0xA0CC10
0xA0CC20
0xA0CC40
Ph IOC 4 Alrm OP A
0xA0CC80
Ph IOC 4 Alrm OP B
0xA0CD00
Ph IOC 4 Alrm OP C
0xA0CE01
0xA0CE02
Ph IOC 5 Alrm OP
0xA0CE08
0xA0CE10
0xA0CE20
0xA0CE40
Ph IOC 5 Alrm OP A
0xA0CE80
Ph IOC 5 Alrm OP B
0xA0CF00
Ph IOC 5 Alrm OP C
0xA0D001
0xA0D002
Ph IOC 6 Alrm OP
0xA0D008
0xA0D010
0xA0D020
11-263
FORMAT CODES
Code
11-264
Type
Definition
0xA0D040
Ph IOC 6 Alrm OP A
0xA0D080
Ph IOC 6 Alrm OP B
0xA0D100
Ph IOC 6 Alrm OP C
0xA0D201
0xA0D202
Ph IOC 7 Alrm OP
0xA0D208
0xA0D210
0xA0D220
0xA0D240
Ph IOC 7 Alrm OP A
0xA0D280
Ph IOC 7 Alrm OP B
0xA0D300
Ph IOC 7 Alrm OP C
0xA0D401
0xA0D402
Ph IOC 8 Alrm OP
0xA0D408
0xA0D410
0xA0D420
0xA0D440
Ph IOC 8 Alrm OP A
0xA0D480
Ph IOC 8 Alrm OP B
0xA0D500
Ph IOC 8 Alrm OP C
0xA0DC01
0xA0DC02
0xA0DE01
0xA0DE02
0xA0E001
0xA0E002
0xA0E201
0xA0E202
0xA0E401
0xA0E402
0xA0E601
0xA0E602
0xA0E801
0xA0E802
0xA0EE01
0xA0EE02
0xA0F001
0xA0F002
0xA0F401
0xA0F402
0xA0F601
0xA0F602
0xA0F801
0xA0F802
0xA0FA01
0xA0FA02
0xA0FC01
0xA0FC02
Code
FORMAT CODES
Type
Definition
0xA10A08
0xA10C01
0xA10C02
RGF 2 Alm OP
0xA10C08
0xA10E01
0xA10E02
RGF 3 Alm OP
0xA10E08
0xA11201
0xA11202
0xA11401
0xA11402
0xA11801
Y
Y
0xA11802
0xA11A01
0xA11A02
0xA12201
0xA12202
Thermal Alm OP
0xA12208
0xA12210
0xA12220
0xA12240
Thermal Alm OP A
0xA12280
Thermal Alm OP B
0xA12300
Thermal Alm OP C
0xA12801
Ph UV 1 Alm PKP
0xA12802
Ph UV 1 Alm OP
0xA12808
Ph UV 1 Alm PKP A
0xA12810
Ph UV 1 Alm PKP B
0xA12820
Ph UV 1 Alm PKP C
0xA12840
Ph UV 1 Alm OP A
0xA12880
Ph UV 1 Alm OP B
0xA12900
Ph UV 1 Alm OP C
0xA12A01
Ph UV 2 Alm PKP
0xA12A02
Ph UV 2 Alm OP
0xA12A08
Ph UV 2 Alm PKP A
0xA12A10
Ph UV 2 Alm PKP B
0xA12A20
Ph UV 2 Alm PKP C
0xA12A40
Ph UV 2 Alm OP A
0xA12A80
Ph UV 2 Alm OP B
0xA12B00
Ph UV 2 Alm OP C
0xA12C01
0xA12C02
Aux UV 1 Alm OP
0xA12E01
0xA12E02
Aux UV 2 Alm OP
0xA13001
Ph OV 1 Alm PKP
0xA13002
Ph OV 1 Alm OP
0xA13008
Ph OV 1 Alm PKP A
0xA13010
Ph OV 1 Alm PKP B
11-265
FORMAT CODES
Code
11-266
Type
Definition
0xA13020
Ph OV 1 Alm PKP C
0xA13040
Ph OV 1 Alm OP A
0xA13080
Ph OV 1 Alm OP B
0xA13100
Ph OV 1 Alm OP C
0xA13201
Ph OV 2 Alm PKP
0xA13202
Ph OV 2 Alm OP
0xA13208
Ph OV 2 Alm PKP A
0xA13210
Ph OV 2 Alm PKP B
0xA13220
Ph OV 2 Alm PKP C
0xA13240
Ph OV 2 Alm OP A
0xA13280
Ph OV 2 Alm OP B
0xA13300
Ph OV 2 Alm OP C
0xA13601
0xA13602
Aux OV 2 Alm OP
0xA13604
0xA13801
0xA13802
Ntrl OV 1 Alm OP
0xA13C01
0xA13C02
NegSeq OV 1 Alm OP
0xA13E01
0xA13E02
NegSeq OV 2 Alm OP
0xA14001
0xA14002
V/Hz 1 Alm OP
0xA14201
0xA14202
V/Hz 2 Alm OP
0xA15401
0xA15402
Underfreq 5 Alm OP
0xA15404
Y
Y
Y
0xA15601
0xA15602
Underfreq 6 Alm OP
0xA15604
0xA15C01
0xA15C02
Overfreq 3 Alm OP
0xA15C04
0xA15E01
0xA15E02
Overfreq 4 Alm OP
0xA15E04
0xA16201
0xA16202
FreqRate2 Alm OP
0xA16208
0xA16210
0xA16240
FreqRate2 Alm Up OP
0xA16280
0xA16401
0xA16402
FreqRate3 Alm OP
0xA16408
0xA16410
Code
FORMAT CODES
Type
Definition
0xA16440
FreqRate3 Alm Up OP
0xA16480
0xA16601
0xA16602
FreqRate4 Alm OP
0xA16608
0xA16610
0xA16640
FreqRate4 Alm Up OP
0xA16680
0xA16801
0xA16802
FreqRate5 Alm OP
0xA16808
0xA16810
0xA16840
FreqRate5 Alm Up OP
0xA16880
0xA16A01
0xA16A02
FreqRate6 Alm OP
0xA16A08
0xA16A10
0xA16A40
FreqRate6 Alm Up OP
0xA16A80
0xA17201
0xA17202
0xA17401
0xA17402
0xA17601
0xA17602
0xA17801
0xA17802
Hotst-Spot Alm OP
0xA17A01
0xA17A02
0xA17C01
0xA17C02
0xA17E01
0xA17E02
0xA18201
0xA18202
0xA18601
0xA18602
0xA18801
0xA18802
0xA1A401
0xA1A408
0xA1A410
0xA1A420
0xA1A601
0xA1A608
0xA1A610
11-267
FORMAT CODES
Code
11-268
Type
Definition
0xA1A620
0xA1A801
0xA1A808
0xA1A810
0xA1A820
0xA1D201
0xA1D202
0xA1D401
0xA1D402
0xA1D601
0xA1D602
0xA1D801
0xA1D802
0xA1DA01
0xA1DA02
0xA1DC01
0xA1DC02
0xA20801
0xA20802
0xA20A01
0xA20A02
0xA20C01
0xA20C02
0xA20E01
0xA20E02
0xA21001
0xA21002
0xA21201
0xA21202
0xA21601
0xA21602
BF2 Alm OP
0xA21608
0xA21610
0xA21620
0xA21640
0xA21801
0xA21802
BF3 Alm OP
0xA21808
0xA21810
0xA21820
0xA21840
0xA23C02
0xA23C08
0xA29601
Y
Y
0xA29602
RTD 1 Alarm OP
0xA29801
0xA29802
RTD 2 Alarm OP
Code
FORMAT CODES
Type
Definition
0xA29A01
0xA29A02
RTD 3 Alarm OP
0xA29C01
0xA29C02
RTD 4 Alarm OP
0xA29E01
0xA29E02
RTD 5 Alarm OP
0xA2A001
0xA2A002
RTD 6 Alarm OP
0xA2A201
0xA2A202
RTD 7 Alarm OP
0xA2A401
0xA2A402
RTD 8 Alarm OP
0xA2A601
0xA2A602
RTD 9 Alarm OP
0xA2A801
0xA2A802
RTD 10 Alarm OP
0xA2AA01
0xA2AA02
RTD 11 Alarm OP
0xA2AC01
0xA2AC02
RTD 12 Alarm OP
0xA2AE01
0xA2AE02
RTD 13 Alarm OP
0xA31A01
0xA31A02
Anlg Ip 1 Alrm OP
0xA31C01
0xA31C02
Anlg Ip 2 Alrm OP
0xA31E01
0xA31E02
Anlg Ip 3 Alrm OP
0xA32001
0xA32002
Anlg Ip 4 Alrm OP
0xA33601
Y
Y
0xA33602
Fast UF 1 Alm OP
0xA33801
0xA33802
Fast UF 2 Alm OP
0xA33A01
0xA33A02
Fast UF 3 Alm OP
0xA33C01
0xA33C02
Fast UF 4 Alm OP
0xA33E01
0xA33E02
Fast UF 5 Alm OP
0xA34001
0xA34002
Fast UF 6 Alm OP
0xA34201
0xA34202
Fast UF 7 Alm OP
0xA34401
0xA34402
Fast UF 8 Alm OP
0xA34602
11-269
FORMAT CODES
Code
11-270
Type
Definition
0xA34801
0xA34808
0xA34810
0xA34820
0xA34C01
0xA34C08
0xA34C10
0xA34C20
0xA34E02
0xA34E40
0xA34E80
0xA34F00
0xA35202
0xA35401
0xA35408
0xA35410
0xA35420
0xA35801
0xA35808
0xA35810
0xA35820
0xA35A02
0xA35A40
0xA35A80
0xA35B00
0xA35E02
0xA36001
0xA36008
0xA36010
0xA36020
0xA36401
0xA36408
0xA36410
0xA36420
0xA36602
0xA36640
0xA36680
0xA36700
0xA36C02
0xA36C40
0xA36C80
0xA36D00
0xA37202
0xA37401
0xA37402
0xA37601
0xA37602
Code
FORMAT CODES
Type
Definition
0xA37801
0xA37802
0xA37A01
0xA37A02
0xA37C01
0xA37C02
0xA37E01
0xA37E02
0xA38001
0xA38002
0xA38401
0xA38402
Unbal Alarm OP
0xA38601
0xA38602
0xA38801
0xA38802
Offline OC Alrm OP
0xA38808
0xA38810
0xA38820
0xA38840
Offline OC Alrm OP A
0xA38880
Offline OC Alrm OP B
0xA38900
Offline OC Alrm OP C
0xA38A01
0xA38A02
0xA38C01
0xA38C02
0xA39008
0xA39010
0xA39040
0xA39080
0xA39401
0xA39402
0xA39801
0xA39802
0xA39A01
0xA39A02
0xA39C01
0xA39C02
0xA39E02
OOS Alrm OP
0xA39E08
0xA39E10
0xA39E20
0xA3A001
0xA3A002
Thermal OL Alrm OP
0xA3A208
0xA3A210
0xA3A240
11-271
FORMAT CODES
Code
11-272
Type
Definition
0xA3A280
0xC08401
Y
Y
0xC08402
0xC08408
0xC08410
0xC08420
0xC08440
0xC08480
0xC08500
0xC08602
0xC08640
0xC08680
0xC08700
0xC08802
0xC08840
0xC08880
0xC08900
0xC08A02
0xC08A40
0xC08A80
0xC08B00
0xC08E02
0xC09002
0xC09202
0xC09208
0xC09210
0xC09220
0xC09240
0xC09280
0xC09300
0xC09402
0xC09408
0xC09410
0xC09420
0xC09440
0xC09480
0xC09500
0xC09602
0xC09640
0xC09680
0xC09700
0xC09802
0xC09840
0xC09880
0xC09900
0xC0B402
0xC0BA01
Y
Y
Y
Y
Y
Code
FORMAT CODES
Type
Definition
0xC0BA02
Overload Trip OP
0xC0BA08
0xC0BA10
0xC0BA20
0xC0BE01
0xC0BE02
0xC0C401
0xC0C402
Ph TOC 3 Trip OP
0xC0C408
0xC0C410
0xC0C420
0xC0C440
Ph TOC 3 Trip OP A
0xC0C480
Ph TOC 3 Trip OP B
0xC0C500
Ph TOC 3 Trip OP C
0xC0CA01
0xC0CA02
Ph IOC 3 Trip OP
0xC0CA08
0xC0CA10
0xC0CA20
0xC0CA40
Ph IOC 3 Trip OP A
0xC0CA80
Ph IOC 3 Trip OP B
0xC0CB00
Ph IOC 3 Trip OP C
0xC0CC01
0xC0CC02
Ph IOC 4 Trip OP
0xC0CC08
0xC0CC10
0xC0CC20
0xC0CC40
Ph IOC 4 Trip OP A
0xC0CC80
Ph IOC 4 Trip OP B
0xC0CD00
Ph IOC 4 Trip OP C
0xC0CE01
0xC0CE02
Ph IOC 5 Trip OP
0xC0CE08
0xC0CE10
0xC0CE20
0xC0CE40
Ph IOC 5 Trip OP A
0xC0CE80
Ph IOC 5 Trip OP B
0xC0CF00
Ph IOC 5 Trip OP C
0xC0D001
0xC0D002
Ph IOC 6 Trip OP
0xC0D008
0xC0D010
0xC0D020
0xC0D040
Ph IOC 6 Trip OP A
0xC0D080
Ph IOC 6 Trip OP B
0xC0D100
Ph IOC 6 Trip OP C
0xC0D201
11-273
FORMAT CODES
Code
11-274
Type
Definition
0xC0D202
Ph IOC 7 Trip OP
0xC0D208
0xC0D210
0xC0D220
0xC0D240
Ph IOC 7 Trip OP A
0xC0D280
Ph IOC 7 Trip OP B
0xC0D300
Ph IOC 7 Trip OP C
0xC0D401
0xC0D402
Ph IOC 8 Trip OP
0xC0D408
0xC0D410
0xC0D420
0xC0D440
Ph IOC 8 Trip OP A
0xC0D480
Ph IOC 8 Trip OP B
0xC0D500
Ph IOC 8 Trip OP C
0xC0DC01
0xC0DC02
0xC0DE01
0xC0DE02
0xC0E001
0xC0E002
0xC0E201
0xC0E202
0xC0E401
0xC0E402
0xC0E601
0xC0E602
0xC0E801
0xC0E802
0xC0EE01
0xC0EE02
0xC0F001
0xC0F002
0xC0F401
0xC0F402
0xC0F601
0xC0F602
0xC0F801
0xC0F802
0xC0FA01
0xC0FA02
0xC0FC01
0xC0FC02
0xC10A08
0xC10C01
0xC10C02
RGF 2 Trip OP
0xC10C08
Code
FORMAT CODES
Type
Definition
0xC10E01
0xC10E02
RGF 3 Trip OP
0xC10E08
0xC11201
0xC11202
0xC11401
0xC11402
0xC11801
0xC11802
0xC11A01
0xC11A02
0xC12201
0xC12202
Thermal Trip OP
0xC12208
0xC12210
0xC12220
0xC12240
Thermal Trip OP A
0xC12280
Thermal Trip OP B
0xC12300
Thermal Trip OP C
0xC12801
Ph UV 1 Trip PKP
0xC12802
Ph UV 1 Trip OP
0xC12808
Ph UV 1 Trip PKP A
0xC12810
Ph UV 1 Trip PKP B
0xC12820
Ph UV 1 Trip PKP C
0xC12840
Ph UV 1 Trip OP A
0xC12880
Ph UV 1 Trip OP B
0xC12900
Ph UV 1 Trip OP C
0xC12A01
Ph UV 2 Trip PKP
0xC12A02
Ph UV 2 Trip OP
0xC12A08
Ph UV 2 Trip PKP A
0xC12A10
Ph UV 2 Trip PKP B
0xC12A20
Ph UV 2 Trip PKP C
0xC12A40
Ph UV 2 Trip OP A
0xC12A80
Ph UV 2 Trip OP B
0xC12B00
Ph UV 2 Trip OP C
0xC12C01
0xC12C02
Aux UV 1 Trip OP
0xC12E01
0xC12E02
Aux UV 2 Trip OP
0xC13001
Ph OV 1 Trip PKP
0xC13002
Ph OV 1 Trip OP
0xC13008
Ph OV 1 Trip PKP A
0xC13010
Ph OV 1 Trip PKP B
0xC13020
Ph OV 1 Trip PKP C
0xC13040
Ph OV 1 Trip OP A
0xC13080
Ph OV 1 Trip OP B
0xC13100
Ph OV 1 Trip OP C
11-275
FORMAT CODES
Code
11-276
Type
Definition
0xC13201
Ph OV 2 Trip PKP
0xC13202
Ph OV 2 Trip OP
0xC13208
Ph OV 2 Trip PKP A
0xC13210
Ph OV 2 Trip PKP B
0xC13220
Ph OV 2 Trip PKP C
0xC13240
Ph OV 2 Trip OP A
0xC13280
Ph OV 2 Trip OP B
0xC13300
Ph OV 2 Trip OP C
0xC13601
0xC13602
Aux OV 2 Trip OP
0xC13604
0xC13801
0xC13802
Ntrl OV 1 Trip OP
0xC13C01
0xC13C02
NegSeq OV 1 Trip OP
0xC13E01
0xC13E02
NegSeq OV 2 Trip OP
0xC14001
Y
Y
Y
Y
Y
0xC14002
V/Hz 1 Trip OP
0xC14201
0xC14202
V/Hz 2 Trip OP
0xC15401
0xC15402
Underfreq 5 Trip OP
0xC15404
0xC15601
0xC15602
Underfreq 6 Trip OP
0xC15604
0xC15C01
0xC15C02
Overfreq 3 Trip OP
0xC15C04
0xC15E01
0xC15E02
Overfreq 4 Trip OP
0xC15E04
0xC16201
0xC16202
FreqRate2 Trip OP
0xC16208
0xC16210
0xC16240
FreqRate2 Trip Up OP
0xC16280
0xC16401
0xC16402
FreqRate3 Trip OP
0xC16408
0xC16410
0xC16440
FreqRate3 Trip Up OP
0xC16480
0xC16601
0xC16602
FreqRate4 Trip OP
Code
FORMAT CODES
Type
Definition
0xC16608
0xC16610
0xC16640
FreqRate4 Trip Up OP
0xC16680
0xC16801
0xC16802
FreqRate5 Trip OP
0xC16808
0xC16810
0xC16840
FreqRate5 Trip Up OP
0xC16880
0xC16A01
0xC16A02
FreqRate6 Trip OP
0xC16A08
0xC16A10
0xC16A40
FreqRate6 Trip Up OP
0xC16A80
0xC20801
0xC20802
0xC20A01
0xC20A02
0xC20C01
0xC20C02
0xC20E01
0xC20E02
0xC21001
0xC21002
0xC21201
0xC21202
0xC21402
BF1 Trip OP
0xC21408
0xC21410
0xC21420
0xC21440
0xC27201
0xC27202
RTD 1 Trip OP
0xC27240
RTD 1 Open
0xC27280
RTD 1 Shorted
0xC27401
0xC27402
RTD 2 Trip OP
0xC27440
RTD 2 Open
0xC27480
RTD 2 Shorted
0xC27601
0xC27602
RTD 3 Trip OP
0xC27640
RTD 3 Open
0xC27680
RTD 3 Shorted
0xC27801
0xC27802
RTD 4 Trip OP
11-277
FORMAT CODES
Code
11-278
Type
Definition
0xC27840
RTD 4 Open
0xC27880
RTD 4 Shorted
0xC27A01
0xC27A02
RTD 5 Trip OP
0xC27A40
RTD 5 Open
0xC27A80
RTD 5 Shorted
0xC27C01
0xC27C02
RTD 6 Trip OP
0xC27C40
RTD 6 Open
0xC27C80
RTD 6 Shorted
0xC27E01
0xC27E02
RTD 7 Trip OP
0xC27E40
RTD 7 Open
0xC27E80
RTD 7 Shorted
0xC28001
0xC28002
RTD 8 Trip OP
0xC28040
RTD 8 Open
0xC28080
RTD 8 Shorted
0xC28201
0xC28202
RTD 9 Trip OP
0xC28240
RTD 9 Open
0xC28280
RTD 9 Shorted
0xC28401
0xC28402
RTD 10 Trip OP
0xC28440
RTD 10 Open
0xC28480
RTD 10 Shorted
0xC28601
0xC28602
RTD 11 Trip OP
0xC28640
RTD 11 Open
0xC28680
RTD 11 Shorted
0xC28801
0xC28802
RTD 12 Trip OP
0xC28840
RTD 12 Open
0xC28880
RTD 12 Shorted
0xC28A01
0xC28A02
RTD 13 Trip OP
0xC28A40
RTD 13 Open
0xC28A80
RTD 13 Shorted
0xC30201
0xC30202
Anlg Ip 1 Trip OP
0xC30401
0xC30402
Anlg Ip 2 Trip OP
0xC30601
0xC30602
Anlg Ip 3 Trip OP
0xC30801
0xC30802
Anlg Ip 4 Trip OP
0xC33601
Code
FORMAT CODES
Type
Definition
0xC33602
Fast UF 1 Trip OP
0xC33801
0xC33802
Fast UF 2 Trip OP
0xC33A01
0xC33A02
Fast UF 3 Trip OP
0xC33C01
0xC33C02
Fast UF 4 Trip OP
0xC33E01
0xC33E02
Fast UF 5 Trip OP
0xC34001
0xC34002
Fast UF 6 Trip OP
0xC34201
0xC34202
Fast UF 7 Trip OP
0xC34401
0xC34402
Fast UF 8 Trip OP
0xC34602
0xC34801
0xC34808
0xC34810
0xC34820
0xC34C01
0xC34C08
0xC34C10
0xC34C20
0xC34E02
0xC34E40
0xC34E80
0xC34F00
0xC36401
0xC36C02
0xC36C40
0xC36C80
0xC36D00
0xC38201
0xC38202
Unbal Trip OP
0xC38204
0xC38601
0xC38602
0xC38801
0xC38802
Offline OC Trip OP
0xC38808
0xC38810
0xC38820
0xC38840
Offline OC Trip OP A
0xC38880
Offline OC Trip OP B
0xC38900
Offline OC Trip OP C
0xC38A01
11-279
FORMAT CODES
Code
FC135
FC137
FC141
FC142
11-280
Type
Definition
0xC38A02
0xC38C01
0xC38C02
0xC38E08
0xC38E10
0xC38E40
0xC38E80
0xC39201
0xC39202
0xC39601
0xC39602
0xC39A01
0xC39A02
0xC39C01
0xC39C02
0xC39E02
OOS Trip OP
0xC39E08
0xC39E10
Y
Y
0xC39E20
unsigned 32 bits
Device Status
0x00040000
Self-Test Fault
0x00080000
Maintenance
0x00100000
In Service
0x00200000
SP Group 6 Active
0x00400000
SP Group 5 Active
0x00800000
SP Group 4 Active
0x01000000
SP Group 3 Active
0x02000000
SP Group 2 Active
0x04000000
Pickup State
0x40000000
Alarm
0x80000000
Trip
unsigned 16 bits
Switching Device
Breaker
Contactor
unsigned 16 bits
Timer Type
Millisecond
Second
Minute
unsigned 32 bits
0x200
CI 1 On
0x201
CI 2 On
0x202
CI 3 On
0x203
CI 4 On
0x204
CI 5 On
0x205
CI 6 On
0x206
CI 7 On
0x207
CI 8 On
Code
FORMAT CODES
Type
Definition
0x208
CI 9 On
0x209
CI 10 On
0x20A
CI 11 On
0x20B
CI 12 On
0x20C
CI 13 On
0x20D
CI 14 On
0x20E
CI 15 On
0x20F
CI 16 On
0x210
CI 17 On
0x211
CI 18 On
0x212
CI 19 On
0x213
CI 20 On
0x214
CI 21 On
0x215
CI 22 On
0x216
CI 23 On
0x217
CI 24 On
0x218
CI 25 On
0x219
CI 26 On
0x21A
CI 27 On
0x21B
CI 28 On
0x21C
CI 29 On
0x21D
CI 30 On
0x21E
CI 31 On
0x21F
CI 32 On
0x220
CI 33 On
0x221
CI 34 On
0x222
CI 35 On
0x223
CI 36 On
0x224
CI 37 On
0x225
CI 38 On
0x226
CI 39 On
0x227
CI 40 On
0x228
CI 41 On
0x229
CI 42 On
0x22A
CI 43 On
0x22B
CI 44 On
0x22C
CI 45 On
0x22D
CI 46 On
0x22E
CI 47 On
0x22F
CI 48 On
0x230
CI 49 On
0x231
CI 50 On
0x232
CI 51 On
0x233
CI 52 On
0x234
CI 53 On
0x235
CI 54 On
0x236
CI 55 On
11-281
FORMAT CODES
Code
11-282
Type
Definition
0x237
CI 56 On
0x238
CI 57 On
0x239
CI 58 On
0x23A
CI 59 On
0x23B
CI 60 On
0x23C
CI 61 On
0x23D
CI 62 On
0x23E
CI 63 On
0x23F
CI 64 On
0x240
CI 65 On
0x241
CI 66 On
0x242
CI 67 On
0x243
CI 68 On
0x244
CI 69 On
0x245
CI 70 On
0x246
CI 71 On
0x247
CI 72 On
0x248
CI 73 On
0x249
CI 74 On
0x24A
CI 75 On
0x24B
CI 76 On
0x24C
CI 77 On
0x24D
CI 78 On
0x24E
CI 79 On
0x24F
CI 80 On
0x250
CI 81 On
0x251
CI 82 On
0x252
CI 83 On
0x253
CI 84 On
0x254
CI 85 On
0x255
CI 86 On
0x256
CI 87 On
0x257
CI 88 On
0x258
CI 89 On
0x259
CI 90 On
0x25A
CI 91 On
0x25B
CI 92 On
0x25C
CI 93 On
0x25D
CI 94 On
0x25E
CI 95 On
0x25F
CI 96 On
0x300
CI 1 Off
0x301
CI 2 Off
0x302
CI 3 Off
0x303
CI 4 Off
0x304
CI 5 Off
0x305
CI 6 Off
Code
FORMAT CODES
Type
Definition
0x306
CI 7 Off
0x307
CI 8 Off
0x308
CI 9 Off
0x309
CI 10 Off
0x30A
CI 11 Off
0x30B
CI 12 Off
0x30C
CI 13 Off
0x30D
CI 14 Off
0x30E
CI 15 Off
0x30F
CI 16 Off
0x310
CI 17 Off
0x311
CI 18 Off
0x312
CI 19 Off
0x313
CI 20 Off
0x314
CI 21 Off
0x315
CI 22 Off
0x316
CI 23 Off
0x317
CI 24 Off
0x318
CI 25 Off
0x319
CI 26 Off
0x31A
CI 27 Off
0x31B
CI 28 Off
0x31C
CI 29 Off
0x31D
CI 30 Off
0x31E
CI 31 Off
0x31F
CI 32 Off
0x320
CI 33 Off
0x321
CI 34 Off
0x322
CI 35 Off
0x323
CI 36 Off
0x324
CI 37 Off
0x325
CI 38 Off
0x326
CI 39 Off
0x327
CI 40 Off
0x328
CI 41 Off
0x329
CI 42 Off
0x32A
CI 43 Off
0x32B
CI 44 Off
0x32C
CI 45 Off
0x32D
CI 46 Off
0x32E
CI 47 Off
0x32F
CI 48 Off
0x330
CI 49 Off
0x331
CI 50 Off
0x332
CI 51 Off
0x333
CI 52 Off
0x334
CI 53 Off
11-283
FORMAT CODES
Code
11-284
Type
Definition
0x335
CI 54 Off
0x336
CI 55 Off
0x337
CI 56 Off
0x338
CI 57 Off
0x339
CI 58 Off
0x33A
CI 59 Off
0x33B
CI 60 Off
0x33C
CI 61 Off
0x33D
CI 62 Off
0x33E
CI 63 Off
0x33F
CI 64 Off
0x340
CI 65 Off
0x341
CI 66 Off
0x342
CI 67 Off
0x343
CI 68 Off
0x344
CI 69 Off
0x345
CI 70 Off
0x346
CI 71 Off
0x347
CI 72 Off
0x348
CI 73 Off
0x349
CI 74 Off
0x34A
CI 75 Off
0x34B
CI 76 Off
0x34C
CI 77 Off
0x34D
CI 78 Off
0x34E
CI 79 Off
0x34F
CI 80 Off
0x350
CI 81 Off
0x351
CI 82 Off
0x352
CI 83 Off
0x353
CI 84 Off
0x354
CI 85 Off
0x355
CI 86 Off
0x356
CI 87 Off
0x357
CI 88 Off
0x358
CI 89 Off
0x359
CI 90 Off
0x35A
CI 91 Off
0x35B
CI 92 Off
0x35C
CI 93 Off
0x35D
CI 94 Off
0x35E
CI 95 Off
0x35F
CI 96 Off
0x400
VI 1 On
0x401
VI 2 On
0x402
VI 3 On
0x403
VI 4 On
Code
FORMAT CODES
Type
Definition
0x404
VI 5 On
0x405
VI 6 On
0x406
VI 7 On
0x407
VI 8 On
0x408
VI 9 On
0x409
VI 10 On
0x40A
VI 11 On
0x40B
VI 12 On
0x40C
VI 13 On
0x40D
VI 14 On
0x40E
VI 15 On
0x40F
VI 16 On
0x410
VI 17 On
0x411
VI 18 On
0x412
VI 19 On
0x413
VI 20 On
0x414
VI 21 On
0x415
VI 22 On
0x416
VI 23 On
0x417
VI 24 On
0x418
VI 25 On
0x419
VI 26 On
0x41A
VI 27 On
0x41B
VI 28 On
0x41C
VI 29 On
0x41D
VI 30 On
0x41E
VI 31 On
0x41F
VI 32 On
0x500
VI 1 Off
0x501
VI 2 Off
0x502
VI 3 Off
0x503
VI 4 Off
0x504
VI 5 Off
0x505
VI 6 Off
0x506
VI 7 Off
0x507
VI 8 Off
0x508
VI 9 Off
0x509
VI 10 Off
0x50A
VI 11 Off
0x50B
VI 12 Off
0x50C
VI 13 Off
0x50D
VI 14 Off
0x50E
VI 15 Off
0x50F
VI 16 Off
0x510
VI 17 Off
0x511
VI 18 Off
0x512
VI 19 Off
11-285
FORMAT CODES
Code
11-286
Type
Definition
0x513
VI 20 Off
0x514
VI 21 Off
0x515
VI 22 Off
0x516
VI 23 Off
0x517
VI 24 Off
0x518
VI 25 Off
0x519
VI 26 Off
0x51A
VI 27 Off
0x51B
VI 28 Off
0x51C
VI 29 Off
0x51D
VI 30 Off
0x51E
VI 31 Off
0x51F
VI 32 Off
0x600
VO 1 On
0x601
VO 2 On
0x602
VO 3 On
0x603
VO 4 On
0x604
VO 5 On
0x605
VO 6 On
0x606
VO 7 On
0x607
VO 8 On
0x608
VO 9 On
0x609
VO 10 On
0x60A
VO 11 On
0x60B
VO 12 On
0x60C
VO 13 On
0x60D
VO 14 On
0x60E
VO 15 On
0x60F
VO 16 On
0x610
VO 17 On
0x611
VO 18 On
0x612
VO 19 On
0x613
VO 20 On
0x614
VO 21 On
0x615
VO 22 On
0x616
VO 23 On
0x617
VO 24 On
0x618
VO 25 On
0x619
VO 26 On
0x61A
VO 27 On
0x61B
VO 28 On
0x61C
VO 29 On
0x61D
VO 30 On
0x61E
VO 31 On
0x61F
VO 32 On
0x700
VO 1 Off
0x701
VO 2 Off
Code
FORMAT CODES
Type
Definition
0x702
VO 3 Off
0x703
VO 4 Off
0x704
VO 5 Off
0x705
VO 6 Off
0x706
VO 7 Off
0x707
VO 8 Off
0x708
VO 9 Off
0x709
VO 10 Off
0x70A
VO 11 Off
0x70B
VO 12 Off
0x70C
VO 13 Off
0x70D
VO 14 Off
0x70E
VO 15 Off
0x70F
VO 16 Off
0x710
VO 17 Off
0x711
VO 18 Off
0x712
VO 19 Off
0x713
VO 20 Off
0x714
VO 21 Off
0x715
VO 22 Off
0x716
VO 23 Off
0x717
VO 24 Off
0x718
VO 25 Off
0x719
VO 26 Off
0x71A
VO 27 Off
0x71B
VO 28 Off
0x71C
VO 29 Off
0x71D
VO 30 Off
0x71E
VO 31 Off
0x71F
VO 32 Off
0x800
Rly 1 On
0x801
Rly 2 On
0x802
Rly 3 On
0x803
Rly 4 On
0x804
Rly 5 On
0x805
Rly 6 On
0x806
Rly 7 On
0x807
Rly 8 On
0x808
Rly 9 On
0x809
Rly 10 On
0x80A
Rly 11 On
0x80B
Rly 12 On
0x80C
Rly 13 On
0x80D
Rly 14 On
0x80E
Rly 15 On
0x80F
Rly 16 On
0x810
Rly 17 On
11-287
FORMAT CODES
Code
11-288
Type
Definition
0x811
Rly 18 On
0x812
Rly 19 On
0x813
Rly 20 On
0x814
Rly 21 On
0x815
Rly 22 On
0x816
Rly 23 On
0x817
Rly 24 On
0x818
Rly 25 On
0x819
Rly 26 On
0x81A
Rly 27 On
0x81B
Rly 28 On
0x81C
Rly 29 On
0x81D
Rly 30 On
0x81E
Rly 31 On
0x81F
Rly 32 On
0x900
Rly 1 Off
0x901
Rly 2 Off
0x902
Rly 3 Off
0x903
Rly 4 Off
0x904
Rly 5 Off
0x905
Rly 6 Off
0x906
Rly 7 Off
0x907
Rly 8 Off
0x908
Rly 9 Off
0x909
Rly 10 Off
0x90A
Rly 11 Off
0x90B
Rly 12 Off
0x90C
Rly 13 Off
0x90D
Rly 14 Off
0x90E
Rly 15 Off
0x90F
Rly 16 Off
0x910
Rly 17 Off
0x911
Rly 18 Off
0x912
Rly 19 Off
0x913
Rly 20 Off
0x914
Rly 21 Off
0x915
Rly 22 Off
0x916
Rly 23 Off
0x917
Rly 24 Off
0x918
Rly 25 Off
0x919
Rly 26 Off
0x91A
Rly 27 Off
0x91B
Rly 28 Off
0x91C
Rly 29 Off
0x91D
Rly 30 Off
0x91E
Rly 31 Off
0x91F
Rly 32 Off
Code
FORMAT CODES
Type
Definition
0xE00
RI 1 On
0xE01
RI 2 On
0xE02
RI 3 On
0xE03
RI 4 On
0xE04
RI 5 On
0xE05
RI 6 On
0xE06
RI 7 On
0xE07
RI 8 On
0xE08
RI 9 On
0xE09
RI 10 On
0xE0A
RI 11 On
0xE0B
RI 12 On
0xE0C
RI 13 On
0xE0D
RI 14 On
0xE0E
RI 15 On
0xE0F
RI 16 On
0xE10
RI 17 On
0xE11
RI 18 On
0xE12
RI 19 On
0xE13
RI 20 On
0xE14
RI 21 On
0xE15
RI 22 On
0xE16
RI 23 On
0xE17
RI 24 On
0xE18
RI 25 On
0xE19
RI 26 On
0xE1A
RI 27 On
0xE1B
RI 28 On
0xE1C
RI 29 On
0xE1D
RI 30 On
0xE1E
RI 31 On
0xE1F
RI 32 On
0xF00
RI 1 Off
0xF01
RI 2 Off
0xF02
RI 3 Off
0xF03
RI 4 Off
0xF04
RI 5 Off
0xF05
RI 6 Off
0xF06
RI 7 Off
0xF07
RI 8 Off
0xF08
RI 9 Off
0xF09
RI 10 Off
0xF0A
RI 11 Off
0xF0B
RI 12 Off
0xF0C
RI 13 Off
0xF0D
RI 14 Off
0xF0E
RI 15 Off
11-289
FORMAT CODES
Code
11-290
Type
Definition
0xF0F
RI 16 Off
0xF10
RI 17 Off
0xF11
RI 18 Off
0xF12
RI 19 Off
0xF13
RI 20 Off
0xF14
RI 21 Off
0xF15
RI 22 Off
0xF16
RI 23 Off
0xF17
RI 24 Off
0xF18
RI 25 Off
0xF19
RI 26 Off
0xF1A
RI 27 Off
0xF1B
RI 28 Off
0xF1C
RI 29 Off
0xF1D
RI 30 Off
0xF1E
RI 31 Off
0xF1F
RI 32 Off
0x1600
BSG3 - Status 1 On
0x1601
BSG3 - Status 2 On
0x1602
BSG3 - Status 3 On
0x1603
BSG3 - Status 4 On
0x1604
BSG3 - Status 5 On
0x1605
BSG3 - Status 6 On
0x1606
BSG3 - Status 7 On
0x1607
BSG3 - Status 8 On
0x1608
BSG3 - Status 9 On
0x1609
BSG3 - Warning 1 On
0x160A
BSG3 - Warning 2 On
0x160B
BSG3 - Warning 3 On
0x160C
BSG3 - Warning 4 On
0x160D
BSG3 - Warning 5 On
0x160E
BSG3 - Warning 6 On
0x160F
BSG3 - Warning 7 On
0x1610
BSG3 - Warning 8 On
0x1611
BSG3 - Warning 9 On
0x1612
BSG3 - Alarm 1 On
0x1613
BSG3 - Alarm 2 On
0x1614
BSG3 - Alarm 3 On
0x1615
BSG3 - Alarm 4 On
0x1616
BSG3 - Alarm 5 On
0x1617
BSG3 - Alarm 6 On
0x1618
BSG3 - Alarm 7 On
0x1619
BSG3 - Alarm 8 On
0x161A
BSG3 - Alarm 9 On
0x1700
0x1701
0x1702
Code
FORMAT CODES
Type
Definition
0x1703
0x1704
0x1705
0x1706
0x1707
0x1708
0x1709
0x170A
0x170B
0x170C
0x170D
0x170E
0x170F
0x1710
0x1711
0x1712
0x1713
0x1714
0x1715
0x1716
0x1717
0x1718
0x1719
0x171A
0x2000
End of List
0x2200
NOT
0x2400
XOR
0x2600
LATCH
0x2802
OR (2 Inputs)
0x2803
OR ( 3 Inputs)
0x2804
OR ( 4 Inputs)
0x2805
OR ( 5 Inputs)
0x2806
OR ( 6 Inputs)
0x2807
OR ( 7 Inputs)
0x2808
OR ( 8 Inputs)
0x2809
OR ( 9 Inputs)
0x280A
OR ( 10 Inputs)
0x280B
OR ( 11 Inputs)
0x280C
OR ( 12 Inputs)
0x280D
OR ( 13 Inputs)
0x280E
OR ( 14 Inputs)
0x280F
OR ( 15 Inputs)
0x2810
OR ( 16 Inputs)
0x2A02
AND ( 2 Inputs)
0x2A03
AND ( 3 Inputs)
0x2A04
AND ( 4 Inputs)
0x2A05
AND ( 5 Inputs)
11-291
FORMAT CODES
Code
11-292
Type
Definition
0x2A06
AND ( 6 Inputs)
0x2A07
AND ( 7 Inputs)
0x2A08
AND ( 8 Inputs)
0x2A09
AND ( 9 Inputs)
0x2A0A
AND ( 10 Inputs)
0x2A0B
AND ( 11 Inputs)
0x2A0C
AND ( 12 Inputs)
0x2A0D
AND ( 13 Inputs)
0x2A0E
AND ( 14 Inputs)
0x2A0F
AND ( 15 Inputs)
0x2A10
AND ( 16 Inputs)
0x2C02
NOR ( 2 Inputs)
0x2C03
NOR ( 3 Inputs)
0x2C04
NOR ( 4 Inputs)
0x2C05
NOR ( 5 Inputs)
0x2C06
NOR ( 6 Inputs)
0x2C07
NOR ( 7 Inputs)
0x2C08
NOR ( 8 Inputs)
0x2C09
NOR ( 9 Inputs)
0x2C0A
NOR ( 10 Inputs)
0x2C0B
NOR ( 11 Inputs)
0x2C0C
NOR ( 12 Inputs)
0x2C0D
NOR ( 13 Inputs)
0x2C0E
NOR ( 14 Inputs)
0x2C0F
NOR ( 15 Inputs)
0x2C10
NOR ( 16 Inputs)
0x2E02
NAND ( 2 Inputs)
0x2E03
NAND ( 3 Inputs)
0x2E04
NAND ( 4 Inputs)
0x2E05
NAND ( 5 Inputs)
0x2E06
NAND ( 6 Inputs)
0x2E07
NAND ( 7 Inputs)
0x2E08
NAND ( 8 Inputs)
0x2E09
NAND ( 9 Inputs)
0x2E0A
NAND ( 10 Inputs)
0x2E0B
NAND ( 11 Inputs)
0x2E0C
NAND ( 12 Inputs)
0x2E0D
NAND ( 13 Inputs)
0x2E0E
NAND ( 14 Inputs)
0x2E0F
NAND ( 15 Inputs)
0x2E10
NAND ( 16 Inputs)
0x3000
TIMER 1
0x3001
TIMER 2
0x3002
TIMER 3
0x3003
TIMER 4
0x3004
TIMER 5
0x3005
TIMER 6
Code
FORMAT CODES
Type
Definition
0x3006
TIMER 7
0x3007
TIMER 8
0x3008
TIMER 9
0x3009
TIMER 10
0x300A
TIMER 11
0x300B
TIMER 12
0x300C
TIMER 13
0x300D
TIMER 14
0x300E
TIMER 15
0x300F
TIMER 16
0x3010
TIMER 17
0x3011
TIMER 18
0x3012
TIMER 19
0x3013
TIMER 20
0x3014
TIMER 21
0x3015
TIMER 22
0x3016
TIMER 23
0x3017
TIMER 24
0x3018
TIMER 25
0x3019
TIMER 26
0x301A
TIMER 27
0x301B
TIMER 28
0x301C
TIMER 29
0x301D
TIMER 30
0x301E
TIMER 31
0x301F
TIMER 32
0x3200
Assign VO 1
0x3201
Assign VO 2
0x3202
Assign VO 3
0x3203
Assign VO 4
0x3204
Assign VO 5
0x3205
Assign VO 6
0x3206
Assign VO 7
0x3207
Assign VO 8
0x3208
Assign VO 9
0x3209
Assign VO 10
0x320A
Assign VO 11
0x320B
Assign VO 12
0x320C
Assign VO 13
0x320D
Assign VO 14
0x320E
Assign VO 15
0x320F
Assign VO 16
0x3210
Assign VO 17
0x3211
Assign VO 18
0x3212
Assign VO 19
0x3213
Assign VO 20
0x3214
Assign VO 21
11-293
FORMAT CODES
Code
11-294
Type
Definition
0x3215
Assign VO 22
0x3216
Assign VO 23
0x3217
Assign VO 24
0x3218
Assign VO 25
0x3219
Assign VO 26
0x321A
Assign VO 27
0x321B
Assign VO 28
0x321C
Assign VO 29
0x321D
Assign VO 30
0x321E
Assign VO 31
0x321F
Assign VO 32
0x3401
0x3402
0x3403
0x800002
Any Trip
0x800202
Any Alarm
0x800802
Any Block
0x800A02
Any PKP
0x800C02
Any OP
0x800E02
Reset OP
0x800E08
Reset OP (PB)
0x800E10
Reset OP (Operand)
0x800E20
Reset OP (Comms)
0x801002
Setpoint Access OP
0x801040
Setting Change
0x801201
0x801204
Authentication Lockout
0x801210
Authentication Fail
0x801220
0x801240
0x801280
0x801300
0x801402
Login
0x801404
Logout
0x801602
Active Target
0x801802
In-Service
0x801C02
0x801E02
0x801E40
IRIG-B Failure
0x801E80
SNTP Failure
0x801F00
PTP Failure
0x802002
PB 1 ON
0x802004
PB 1 OFF
0x802202
PB 2 ON
0x802204
PB 2 OFF
0x802402
PB 3 ON
0x802404
PB 3 OFF
Code
FORMAT CODES
Type
Definition
0x802602
Von
0x802604
Voff
0x802802
Von
0x802804
Voff
0x802A02
Von
0x802A04
Voff
0x802C02
Von
0x802C04
Voff
0x802E02
Von
0x802E04
Voff
0x803002
Von
0x803004
Voff
0x803202
Critical Fail OP
0x803601
Motor Starting
0x803602
Motor Running
0x803604
Motor Stopped
0x803608
Motor Speed 2
0x803610
Speed2 TR 2-1 OP
0x803620
0x803640
Motor Overload
0x803680
Motor Tripped
0x803700
Emergency Restart
0x803802
BKR1 Closed
0x803A02
BKR1 Opened
0x803C02
0x803C04
0x803E02
BKR1 Disconnected
0x803E04
BKR1 Connected
0x804002
BKR1 52a CI ON
0x804004
0x804202
BKR1 52b CI ON
0x804204
0x804402
BKR2 Closed
0x804602
BKR2 Opened
0x804802
0x804804
0x804A02
BKR2 Disconnected
0x804A04
BKR2 Connected
0x804C02
BKR2 52a CI ON
0x804C04
0x804E02
BKR2 52b CI ON
0x804E04
0x805002
BKR3 Closed
0x805202
BKR3 Opened
0x805402
0x805404
0x805602
BKR3 Disconnected
11-295
FORMAT CODES
Code
11-296
Type
Definition
0x805604
BKR3 Connected
0x805802
BKR3 52a CI ON
0x805804
0x805A02
BKR3 52b CI ON
0x805A04
0x805C02
Contactor Closed
0x805E02
Contactor Open
0x806002
0x806004
0x806202
Contactor Disconnect
0x806204
Contactor Connected
0x806408
Local Stop
0x806410
Remote Stop
0x806608
Local Start
0x806610
Remote Start
0x808040
VFD Bypassed
0x808080
0x808201
0x808202
Percent Diff OP
0x808208
0x808210
0x808220
0x808240
Percent Diff OP A
0x808280
Percent Diff OP B
0x808300
Percent Diff OP C
0x808401
0x808402
0x808408
0x808410
0x808420
0x808440
0x808480
0x808500
0x808602
0x808640
0x808680
0x808700
0x808802
0x808840
0x808880
0x808900
0x808A02
0x808A40
0x808A80
0x808B00
0x808C02
0x808C40
Code
FORMAT CODES
Type
Definition
0x808C80
0x808D00
0x808E02
0x809002
0x809202
0x809208
0x809210
0x809220
0x809240
0x809280
0x809300
0x809402
0x809408
0x809410
0x809420
0x809440
0x809480
0x809500
0x809602
Instant Diff OP
0x809640
Instant Diff OP A
0x809680
Instant Diff OP B
0x809700
Instant Diff OP C
0x809802
Instant Diff OP
0x809840
Instant Diff OP A
0x809880
Instant Diff OP B
0x809900
Instant Diff OP C
0x809A01
Thermal PKP
0x809A02
Thermal OP
0x80A001
0x80A002
Cur Unbal OP
0x80A040
Single Phasing OP
0x80A201
0x80A202
Mech Jam OP
0x80A601
Undercur PKP
0x80A602
Undercur OP
0x80A801
Overload PKP
0x80A802
Overload OP
0x80AA01
0x80AA02
Short Circuit OP
0x80B001
GndFault PKP
0x80B002
GndFault OP
0x80B202
0x80B402
0x80B801
Underpwr PKP
0x80B802
Underpwr OP
0x80BA01
Overload PKP
0x80BA02
Overload OP
11-297
FORMAT CODES
Code
11-298
Type
Definition
0x80BA08
W1 Overload PKP
0x80BA10
W2 Overload PKP
0x80BA20
W3 Overload PKP
0x80BE01
0x80BE02
Spd2 U/C OP
0x80C001
Ph TOC 1 PKP
0x80C002
Ph TOC 1 OP
0x80C008
Ph TOC 1 PKP A
0x80C010
Ph TOC 1 PKP B
0x80C020
Ph TOC 1 PKP C
0x80C040
Ph TOC 1 OP A
0x80C080
Ph TOC 1 OP B
0x80C100
Ph TOC 1 OP C
0x80C201
Ph TOC 2 PKP
0x80C202
Ph TOC 2 OP
0x80C208
Ph TOC 2 PKP A
0x80C210
Ph TOC 2 PKP B
0x80C220
Ph TOC 2 PKP C
0x80C240
Ph TOC 2 OP A
0x80C280
Ph TOC 2 OP B
0x80C300
Ph TOC 2 OP C
0x80C401
Ph TOC 3 PKP
0x80C402
Ph TOC 3 OP
0x80C408
Ph TOC 3 PKP A
0x80C410
Ph TOC 3 PKP B
0x80C420
Ph TOC 3 PKP C
0x80C440
Ph TOC 3 OP A
0x80C480
Ph TOC 3 OP B
0x80C500
Ph TOC 3 OP C
0x80C601
Ph IOC 1 PKP
0x80C602
Ph IOC 1 OP
0x80C608
Ph IOC 1 PKP A
0x80C610
Ph IOC 1 PKP B
0x80C620
Ph IOC 1 PKP C
0x80C640
Ph IOC 1 OP A
0x80C680
Ph IOC 1 OP B
0x80C700
Ph IOC 1 OP C
0x80C801
Ph IOC 2 PKP
0x80C802
Ph IOC 2 OP
0x80C808
Ph IOC 2 PKP A
0x80C810
Ph IOC 2 PKP B
0x80C820
Ph IOC 2 PKP C
0x80C840
Ph IOC 2 OP A
0x80C880
Ph IOC 2 OP B
0x80C900
Ph IOC 2 OP C
0x80CA01
Ph IOC 3 PKP
0x80CA02
Ph IOC 3 OP
Y
Y
Code
FORMAT CODES
Type
Definition
0x80CA08
Ph IOC 3 PKP A
0x80CA10
Ph IOC 3 PKP B
0x80CA20
Ph IOC 3 PKP C
0x80CA40
Ph IOC 3 OP A
0x80CA80
Ph IOC 3 OP B
0x80CB00
Ph IOC 3 OP C
0x80CC01
Ph IOC 4 PKP
0x80CC02
Ph IOC 4 OP
0x80CC08
Ph IOC 4 PKP A
0x80CC10
Ph IOC 4 PKP B
0x80CC20
Ph IOC 4 PKP C
0x80CC40
Ph IOC 4 OP A
0x80CC80
Ph IOC 4 OP B
0x80CD00
Ph IOC 4 OP C
0x80CE01
Ph IOC 5 PKP
0x80CE02
Ph IOC 5 OP
0x80CE08
Ph IOC 5 PKP A
0x80CE10
Ph IOC 5 PKP B
0x80CE20
Ph IOC 5 PKP C
0x80CE40
Ph IOC 5 OP A
0x80CE80
Ph IOC 5 OP B
0x80CF00
Ph IOC 5 OP C
0x80D001
Ph IOC 6 PKP
0x80D002
Ph IOC 6 OP
0x80D008
Ph IOC 6 PKP A
0x80D010
Ph IOC 6 PKP B
0x80D020
Ph IOC 6 PKP C
0x80D040
Ph IOC 6 OP A
0x80D080
Ph IOC 6 OP B
0x80D100
Ph IOC 6 OP C
0x80D201
Ph IOC 7 PKP
0x80D202
Ph IOC 7 OP
0x80D208
Ph IOC 7 PKP A
0x80D210
Ph IOC 7 PKP B
0x80D220
Ph IOC 7 PKP C
0x80D240
Ph IOC 7 OP A
0x80D280
Ph IOC 7 OP B
0x80D300
Ph IOC 7 OP C
0x80D401
Ph IOC 8 PKP
0x80D402
Ph IOC 8 OP
0x80D408
Ph IOC 8 PKP A
0x80D410
Ph IOC 8 PKP B
0x80D420
Ph IOC 8 PKP C
0x80D440
Ph IOC 8 OP A
0x80D480
Ph IOC 8 OP B
0x80D500
Ph IOC 8 OP C
0x80D602
Ph Dir OC REV
11-299
FORMAT CODES
Code
11-300
Type
Definition
0x80D640
Ph Dir OC REV A
0x80D680
Ph Dir OC REV B
0x80D700
Ph Dir OC REV C
0x80D801
0x80D802
Ntrl TOC 1 OP
0x80DA01
0x80DA02
Ntrl TOC 2 OP
0x80DC01
0x80DC02
Ntrl TOC 3 OP
0x80DE01
0x80DE02
Ntrl IOC 1 OP
0x80E001
0x80E002
Ntrl IOC 2 OP
0x80E201
0x80E202
Ntrl IOC 3 OP
0x80E401
0x80E402
Ntrl IOC 4 OP
0x80E601
Y
Y
Y
0x80E602
Ntrl IOC 5 OP
0x80E801
0x80E802
Ntrl IOC 6 OP
0x80EA08
0x80EA40
0x80EC01
0x80EC02
GND TOC 1 OP
0x80EE01
0x80EE02
GND TOC 2 OP
0x80F001
0x80F002
GND TOC 3 OP
0x80F201
0x80F202
GND IOC 1 OP
0x80F401
0x80F402
GND IOC 2 OP
0x80F601
Y
Y
0x80F602
GND IOC 3 OP
0x80F801
0x80F802
GND IOC 4 OP
0x80FA01
0x80FA02
GND IOC 5 OP
0x80FC01
0x80FC02
GND IOC 6 OP
0x810001
Y
Y
0x810002
SGND TOC 1 OP
0x810A01
RGF 1 PKP
0x810A02
RGF 1 OP
0x810A08
RGF 1 Superv ON
0x810C01
RGF 2 PKP
Code
FORMAT CODES
Type
Definition
0x810C02
RGF 2 OP
0x810C08
RGF 2 Superv ON
0x810E01
RGF 3 PKP
0x810E02
RGF 3 OP
0x810E08
RGF 3 Superv ON
0x811001
0x811002
NegSeq TOC 1 OP
0x811201
0x811202
NegSeq TOC 2 OP
0x811401
0x811402
NegSeq TOC 3 OP
0x811601
0x811602
NegSeq IOC 1 OP
0x811801
0x811802
NegSeq IOC 2 OP
0x811A01
0x811A02
NegSeq IOC 3 OP
0x811C08
0x811C40
0x811E01
0x811E02
Broken Cond OP
0x812001
0x812002
Load Encro OP
0x812201
Thermal PKP
0x812202
Thermal OP
0x812208
Thermal PKP A
0x812210
Thermal PKP B
0x812220
Thermal PKP C
0x812240
Thermal OP A
0x812280
Thermal OP B
0x812300
Thermal OP C
0x812402
Thermal Alarm
0x812440
Thermal Alarm A
0x812480
Thermal Alarm B
0x812500
Thermal Alarm C
0x812601
0x812602
Phase Rev OP
0x812640
0x812801
Ph UV 1 PKP
0x812802
Ph UV 1 OP
0x812808
Ph UV 1 PKP A
0x812810
Ph UV 1 PKP B
0x812820
Ph UV 1 PKP C
0x812840
Ph UV 1 OP A
0x812880
Ph UV 1 OP B
0x812900
Ph UV 1 OP C
0x812A01
Ph UV 2 PKP
11-301
FORMAT CODES
Code
11-302
Type
Definition
0x812A02
Ph UV 2 OP
0x812A08
Ph UV 2 PKP A
0x812A10
Ph UV 2 PKP B
0x812A20
Ph UV 2 PKP C
0x812A40
Ph UV 2 OP A
0x812A80
Ph UV 2 OP B
0x812B00
Ph UV 2 OP C
0x812C01
Aux UV 1 PKP
0x812C02
Aux UV 1 OP
0x812E01
Aux UV 2 PKP
0x812E02
Aux UV 2 OP
0x813001
Ph OV 1 PKP
0x813002
Ph OV 1 OP
0x813008
Ph OV 1 PKP A
0x813010
Ph OV 1 PKP B
0x813020
Ph OV 1 PKP C
0x813040
Ph OV 1 OP A
0x813080
Ph OV 1 OP B
0x813100
Ph OV 1 OP C
0x813201
Ph OV 2 PKP
0x813202
Ph OV 2 OP
0x813208
Ph OV 2 PKP A
0x813210
Ph OV 2 PKP B
0x813220
Ph OV 2 PKP C
0x813240
Ph OV 2 OP A
0x813280
Ph OV 2 OP B
0x813300
Ph OV 2 OP C
0x813401
Aux OV 1 PKP
0x813402
Aux OV 1 OP
0x813601
Aux OV 2 PKP
0x813602
Aux OV 2 OP
0x813604
Aux OV 2 DPO
0x813801
Ntrl OV 1 PKP
Y
Y
0x813802
Ntrl OV 1 OP
0x813C01
NegSeq OV 1 PKP
0x813C02
NegSeq OV 1 OP
0x813E01
NegSeq OV 2 PKP
0x813E02
NegSeq OV 2 OP
0x814001
V/Hz 1 PKP
Y
Y
Y
0x814002
V/Hz 1 OP
0x814201
V/Hz 2 PKP
0x814202
V/Hz 2 OP
0x814401
DirPwr 1 PKP
0x814402
DirPwr 1 OP
0x814408
0x814410
0x814440
DirPwr 1 Stg1 OP
Code
FORMAT CODES
Type
Definition
0x814480
DirPwr 1 Stg2 OP
0x814601
DirPwr 2 PKP
0x814602
DirPwr 2 OP
0x814608
0x814610
0x814640
DirPwr 2 Stg1 OP
0x814680
DirPwr 2 Stg2 OP
0x814801
0x814802
Watt GndFlt 1 OP
0x814C01
Underfreq 1 PKP
0x814C02
Underfreq 1 OP
0x814E01
Underfreq 2 PKP
0x814E02
Underfreq 2 OP
0x815001
Underfreq 3 PKP
0x815002
Underfreq 3 OP
0x815201
Underfreq 4 PKP
0x815202
Underfreq 4 OP
0x815401
Underfreq 5 PKP
0x815402
Underfreq 5 OP
0x815601
Underfreq 6 PKP
0x815602
Underfreq 6 OP
0x815801
Overfreq 1 PKP
0x815802
Overfreq 1 OP
0x815A01
Overfreq 2 PKP
0x815A02
Overfreq 2 OP
0x815C01
Overfreq 3 PKP
0x815C02
Overfreq 3 OP
0x815E01
Overfreq 4 PKP
0x815E02
Overfreq 4 OP
0x816001
FreqRate1 PKP
0x816002
FreqRate1 OP
0x816008
FreqRate1 Up PKP
0x816010
0x816040
FreqRate1 Up OP
0x816080
FreqRate1 Dwn OP
0x816201
FreqRate2 PKP
0x816202
FreqRate2 OP
0x816208
FreqRate2 Up PKP
0x816210
0x816240
FreqRate2 Up OP
0x816280
FreqRate2 Dwn OP
0x816401
FreqRate3 PKP
0x816402
FreqRate3 OP
0x816408
FreqRate3 Up PKP
0x816410
0x816440
FreqRate3 Up OP
0x816480
FreqRate3 Dwn OP
11-303
FORMAT CODES
Code
11-304
Type
Definition
0x816601
FreqRate4 PKP
0x816602
FreqRate4 OP
0x816608
FreqRate4 Up PKP
0x816610
0x816640
FreqRate4 Up OP
0x816680
FreqRate4 Dwn OP
0x816801
FreqRate5 PKP
0x816802
FreqRate5 OP
0x816808
FreqRate5 Up PKP
0x816810
0x816840
FreqRate5 Up OP
0x816880
FreqRate5 Dwn OP
0x816A01
FreqRate6 PKP
0x816A02
FreqRate6 OP
0x816A08
FreqRate6 Up PKP
0x816A10
0x816A40
FreqRate6 Up OP
0x816A80
FreqRate6 Dwn OP
0x816C02
Xfmr Energized
0x816C04
Xfmr De-Energized
0x816C08
Not Configured
0x816E08
0x816E10
0x816E20
0x816E40
TC at Min Tap ON
0x816E80
TC at Ntrl Tap ON
0x816F00
TC at Max Tap ON
0x817002
0x817201
0x817202
W1 Hmc Der OP
0x817401
0x817402
W2 Hmc Der OP
0x817601
0x817602
W3 Hmc Der OP
0x817801
Hotst-Spot PKP
0x817802
Hotst-Spot OP
0x817A01
0x817A02
Aging Fctr OP
0x817C01
0x817C02
Xfmr LOL OP
0x817E01
0x817E02
Tap Ch Fail OP
0x818001
0x818002
TripCoil Mon 1 OP
0x818201
0x818202
TripCoil Mon 2 OP
0x818401
Code
FORMAT CODES
Type
Definition
0x818402
TripCoil Mon 3 OP
0x818601
0x818602
0x818801
0x818802
0x818A01
0x818A02
0x818C02
BKR1 Arc OP
0x818E02
BKR2 Arc OP
0x819002
BKR3 Arc OP
0x819201
0x819202
Y
Y
0x819208
0x819210
0x819220
0x819240
0x819401
0x819402
0x819408
0x819410
0x819420
0x819440
0x819601
0x819602
0x819608
0x819610
0x819620
0x819640
0x819801
0x819808
0x819810
0x819820
0x819840
0x819880
0x819900
0x819A01
0x819A08
0x819A10
0x819A20
0x819A40
0x819A80
0x819B00
0x819E01
0x819E02
0x81A008
PF 1 Switch-In
0x81A010
PF 1 Switch-Out
0x81A040
PF 1 Switch-In OP
11-305
FORMAT CODES
Code
11-306
Type
Definition
0x81A080
PF 1 Switch-Out OP
0x81A208
PF 2 Switch-In
0x81A210
PF 2 Switch-Out
0x81A240
PF 2 Switch-In OP
0x81A280
PF 2 Switch-Out OP
0x81A401
0x81A408
0x81A410
0x81A420
0x81A601
0x81A608
0x81A610
0x81A620
0x81A801
0x81A808
0x81A810
0x81A820
0x81AA01
0x81AC01
0x81AE01
0x81B008
0x81B010
0x81B020
0x81B040
0x81B208
Counter 1 LO
0x81B210
Counter 1 EQL
0x81B220
Counter 1 HI
0x81B240
Counter 1 at Limit
0x81B408
Counter 2 LO
0x81B410
Counter 2 EQL
0x81B420
Counter 2 HI
0x81B440
Counter 2 at Limit
0x81B608
Counter 3 LO
0x81B610
Counter 3 EQL
0x81B620
Counter 3 HI
0x81B640
Counter 3 at Limit
0x81B808
Counter 4 LO
0x81B810
Counter 4 EQL
0x81B820
Counter 4 HI
0x81B840
Counter 4 at Limit
0x81BA08
Counter 5 LO
0x81BA10
Counter 5 EQL
0x81BA20
Counter 5 HI
0x81BA40
Counter 5 at Limit
0x81BC08
Counter 6 LO
0x81BC10
Counter 6 EQL
0x81BC20
Counter 6 HI
Code
FORMAT CODES
Type
Definition
0x81BC40
Counter 6 at Limit
0x81BE08
Counter 7 LO
0x81BE10
Counter 7 EQL
0x81BE20
Counter 7 HI
0x81BE40
Counter 7 at Limit
0x81C008
Counter 8 LO
0x81C010
Counter 8 EQL
0x81C020
Counter 8 HI
0x81C040
Counter 8 at Limit
0x81C208
Counter 9 LO
0x81C210
Counter 9 EQL
0x81C220
Counter 9 HI
0x81C240
Counter 9 at Limit
0x81C408
Counter 10 LO
0x81C410
Counter 10 EQL
0x81C420
Counter 10 HI
0x81C440
Counter 10 at Limit
0x81C608
Counter 11 LO
0x81C610
Counter 11 EQL
0x81C620
Counter 11 HI
0x81C640
Counter 11 at Limit
0x81C808
Counter 12 LO
0x81C810
Counter 12 EQL
0x81C820
Counter 12 HI
0x81C840
Counter 12 at Limit
0x81CA08
Counter 13 LO
0x81CA10
Counter 13 EQL
0x81CA20
Counter 13 HI
0x81CA40
Counter 13 at Limit
0x81CC08
Counter 14 LO
0x81CC10
Counter 14 EQL
0x81CC20
Counter 14 HI
0x81CC40
Counter 14 at Limit
0x81CE08
Counter 15 LO
0x81CE10
Counter 15 EQL
0x81CE20
Counter 15 HI
0x81CE40
Counter 15 at Limit
0x81D008
Counter 16 LO
0x81D010
Counter 16 EQL
0x81D020
Counter 16 HI
0x81D040
Counter 16 at Limit
0x81D201
0x81D202
Harm Det 1 OP
0x81D401
0x81D402
Harm Det 2 OP
0x81D601
0x81D602
Harm Det 3 OP
11-307
FORMAT CODES
Code
11-308
Type
Definition
0x81D801
0x81D802
Harm Det 4 OP
0x81DA01
0x81DA02
Harm Det 5 OP
0x81DC01
0x81DC02
Harm Det 6 OP
0x81DE02
Start Inhibit
0x81E040
Clear Events
0x81E080
Clear Transient
0x81E100
0x81E202
Group 1 Active
0x81E402
Group 2 Active
0x81E602
Group 3 Active
0x81E802
Group 4 Active
0x81EA02
Group 5 Active
0x81EC02
Group 6 Active
0x81EE01
0x81EE02
Thermal Inhibit OP
0x81F001
0x81F002
0x81F201
0x81F202
0x81F401
0x81F402
Restart Delay OP
0x81F602
0x81F802
0x81FA08
Local Mode ON
0x81FA10
0x81FA40
BKR1 Selected
0x81FA80
BKR2 Selected
0x81FB00
BKR3 Selected
0x81FC08
0x81FC10
0x81FE08
0x81FE10
0x820008
Y
Y
0x820010
0x820208
Y
Y
0x820210
0x820408
0x820410
0x820608
0x820610
0x820801
0x820802
Trip Bus 1 OP
0x820A01
0x820A02
Trip Bus 2 OP
Y
Y
Code
FORMAT CODES
Type
Definition
0x820C01
0x820C02
Trip Bus 3 OP
0x820E01
0x820E02
Trip Bus 4 OP
0x821001
0x821002
Trip Bus 5 OP
0x821201
0x821202
Trip Bus 6 OP
0x821402
BF1 OP
0x821408
BF1 Retrip
0x821410
BF1 Highset OP
0x821420
BF1 Lowset OP
0x821440
0x821602
BF2 OP
0x821608
BF2 Retrip
0x821610
BF2 Highset OP
0x821620
BF2 Lowset OP
0x821640
0x821802
BF3 OP
0x821808
BF3 Retrip
0x821810
BF3 Highset OP
0x821820
BF3 Lowset OP
0x821840
0x821A02
0x821A08
0x821A10
0x821A20
0x821A40
0x821A80
0x821B00
Sync1 OK
0x821E02
0x822001
0x822002
Cold Load 1 OP
0x822401
Ph UV Restore PKP
0x822408
0x822440
Aux UV Restore OP
0x822480
Ph UV Restore OP
0x822500
UV Restore Init
0x822601
UF Restore PKP
0x822602
UF Restore OP
0x822640
UF Restore Init
0x822801
0x822802
0x822804
0x822808
0x822810
0x822820
11-309
FORMAT CODES
Code
11-310
Type
Definition
0x822840
0x822880
Tie-BKR Conn&Clsd
0x822900
0x822A02
Transfer Initiated
0x822C01
AR1 Disabled
0x822C08
AR1 Enabled
0x822C10
AR1 Initiated
0x822C20
AR1 In Progress
0x822C40
AR1 Close
0x822C80
AR1 Lockout
0x822D00
0x822E08
0x822E10
0x822E20
0x822E40
0x822E80
0x823008
AR1 ShotRdc to 1
0x823010
AR1 ShotRdc to 2
0x823020
AR1 ShotRdc to 3
0x823040
AR1 ShotRdc to LO
0x823208
0x823210
0x823220
AR1 Coordinating
0x823C02
VT Fuse Fail1 OP
0x823C08
VT Fuse1 V Loss
0x824002
NV Latch 1 ON
0x824004
NV Latch 1 OFF
0x824202
NV Latch 2 ON
0x824204
NV Latch 2 OFF
0x824402
NV Latch 3 ON
0x824404
NV Latch 3 OFF
0x824602
NV Latch 4 ON
0x824604
NV Latch 4 OFF
0x824802
NV Latch 5 ON
0x824804
NV Latch 5 OFF
0x824A02
NV Latch 6 ON
0x824A04
NV Latch 6 OFF
0x824C02
NV Latch 7 ON
0x824C04
NV Latch 7 OFF
0x824E02
NV Latch 8 ON
0x824E04
NV Latch 8 OFF
0x825002
NV Latch 9 ON
0x825004
NV Latch 9 OFF
0x825202
NV Latch 10 ON
0x825204
NV Latch 10 OFF
0x825402
NV Latch 11 ON
0x825404
NV Latch 11 OFF
Code
FORMAT CODES
Type
Definition
0x825602
NV Latch 12 ON
0x825604
NV Latch 12 OFF
0x825802
NV Latch 13 ON
0x825804
NV Latch 13 OFF
0x825A02
NV Latch 14 ON
0x825A04
NV Latch 14 OFF
0x825C02
NV Latch 15 ON
0x825C04
NV Latch 15 OFF
0x825E02
NV Latch 16 ON
0x825E04
NV Latch 16 OFF
0x826001
FlexEl 1 PKP
0x826002
FlexEl 1 OP
0x826201
FlexEl 2 PKP
0x826202
FlexEl 2 OP
0x826401
FlexEl 3 PKP
0x826402
FlexEl 3 OP
0x826601
FlexEl 4 PKP
0x826602
FlexEl 4 OP
0x826801
FlexEl 5 PKP
0x826802
FlexEl 5 OP
0x826A01
FlexEl 6 PKP
0x826A02
FlexEl 6 OP
0x826C01
FlexEl 7 PKP
0x826C02
FlexEl 7 OP
0x826E01
FlexEl 8 PKP
0x826E02
FlexEl 8 OP
0x827002
Hot RTD
0x827201
RTD 1 PKP
0x827202
RTD 1 OP
0x827240
RTD 1 Open
0x827280
RTD 1 Shorted
0x827401
RTD 2 PKP
0x827402
RTD 2 OP
0x827440
RTD 2 Open
0x827480
RTD 2 Shorted
0x827601
RTD 3 PKP
0x827602
RTD 3 OP
0x827640
RTD 3 Open
0x827680
RTD 3 Shorted
0x827801
RTD 4 PKP
0x827802
RTD 4 OP
0x827840
RTD 4 Open
0x827880
RTD 4 Shorted
0x827A01
RTD 5 PKP
0x827A02
RTD 5 OP
0x827A40
RTD 5 Open
0x827A80
RTD 5 Shorted
11-311
FORMAT CODES
Code
11-312
Type
Definition
0x827C01
RTD 6 PKP
0x827C02
RTD 6 OP
0x827C40
RTD 6 Open
0x827C80
RTD 6 Shorted
0x827E01
RTD 7 PKP
0x827E02
RTD 7 OP
0x827E40
RTD 7 Open
0x827E80
RTD 7 Shorted
0x828001
RTD 8 PKP
0x828002
RTD 8 OP
0x828040
RTD 8 Open
0x828080
RTD 8 Shorted
0x828201
RTD 9 PKP
0x828202
RTD 9 OP
0x828240
RTD 9 Open
0x828280
RTD 9 Shorted
0x828401
RTD 10 PKP
0x828402
RTD 10 OP
0x828440
RTD 10 Open
0x828480
RTD 10 Shorted
0x828601
RTD 11 PKP
0x828602
RTD 11 OP
0x828640
RTD 11 Open
0x828680
RTD 11 Shorted
0x828801
RTD 12 PKP
0x828802
RTD 12 OP
0x828840
RTD 12 Open
0x828880
RTD 12 Shorted
0x828A01
RTD 13 PKP
0x828A02
RTD 13 OP
0x828A40
RTD 13 Open
0x828A80
RTD 13 Shorted
0x830201
Anlg Ip 1 PKP
0x830202
Anlg Ip 1 OP
0x830401
Anlg Ip 2 PKP
0x830402
Anlg Ip 2 OP
0x830601
Anlg Ip 3 PKP
0x830602
Anlg Ip 3 OP
0x830801
Anlg Ip 4 PKP
0x830802
Anlg Ip 4 OP
0x833402
0x833601
Fast UF 1 PKP
0x833602
Fast UF 1 OP
0x833801
Fast UF 2 PKP
0x833802
Fast UF 2 OP
0x833A01
Fast UF 3 PKP
0x833A02
Fast UF 3 OP
Code
FORMAT CODES
Type
Definition
0x833C01
Fast UF 4 PKP
0x833C02
Fast UF 4 OP
0x833E01
Fast UF 5 PKP
0x833E02
Fast UF 5 OP
0x834001
Fast UF 6 PKP
0x834002
Fast UF 6 OP
0x834201
Fast UF 7 PKP
0x834202
Fast UF 7 OP
0x834401
Fast UF 8 PKP
0x834402
Fast UF 8 OP
0x834602
Arc Flash 1 OP
0x834801
AF 1 Light 1 PKP
0x834808
AF 1 Light 2 PKP
0x834810
AF 1 Light 3 PKP
0x834820
AF 1 Light 4 PKP
0x834C01
0x834C08
AF 1 HS Ph IOC PKP A
0x834C10
AF 1 HS Ph IOC PKP B
0x834C20
AF 1 HS Ph IOC PKP C
0x834E02
Arc Flash 1 S1 OP
0x834E40
Arc Flash 1 S2 OP
0x834E80
Arc Flash 1 S3 OP
0x834F00
Arc Flash 1 S4 OP
0x836A02
0x836C02
0x836C40
0x836C80
0x836D00
0x837001
Offline
0x837002
Online
0x837008
Tripped
0x837202
Run Hrs OP
0x837401
0x837402
0x837601
0x837602
0x837801
0x837802
0x837A01
0x837A02
0x837C01
0x837C02
0x837E01
0x837E02
0x838001
0x838002
0x838201
Unbal PKP
11-313
FORMAT CODES
Code
11-314
Type
Definition
0x838202
Unbal OP
0x838204
Unbal DPO
0x838601
0x838602
Inadv Energ OP
0x838801
Offline OC PKP
0x838802
Offline OC OP
0x838808
Offline OC PKP A
0x838810
Offline OC PKP B
0x838820
Offline OC PKP C
0x838840
Offline OC OP A
0x838880
Offline OC OP B
0x838900
Offline OC OP C
0x838A01
0x838A02
0x838C01
0x838C02
Seq Shtdn OP
0x838E08
0x838E10
0x838E40
Pos Mvar OP
0x838E80
Neg Mvar OP
0x839201
0x839202
3rd Ntr UV OP
0x839601
0x839602
3rd V Dif OP
0x839A01
0x839A02
LOE Circle 1 OP
0x839C01
0x839C02
LOE Circle 2 OP
0x839E02
OOS OP
0x839E08
0x839E10
0x839E20
0x83A001
Thermal OL PKP
0x83A002
Thermal OL OP
0x83A208
0x83A210
0x83A240
0x83A280
0x83A402
DGA Alarm OP
0x83A608
Device 1 Offline
0xA09C02
Thermal Alarm OP
Y
Y
0xA09E01
0xA09E02
0xA0A401
0xA0A402
Undercur Alarm OP
0xA0AE01
0xA0AE02
GndFault Alarm OP
Code
FORMAT CODES
Type
Definition
0xA0B601
0xA0B602
Underpwr Alarm OP
0xA0BC01
0xA0BC02
0xA17E01
0xA17E02
0xA29601
Y
Y
Y
0xA29602
RTD 1 Alarm OP
0xA29801
0xA29802
RTD 2 Alarm OP
0xA29A01
0xA29A02
RTD 3 Alarm OP
0xA29C01
0xA29C02
RTD 4 Alarm OP
0xA29E01
0xA29E02
RTD 5 Alarm OP
0xA2A001
0xA2A002
RTD 6 Alarm OP
0xA2A201
0xA2A202
RTD 7 Alarm OP
0xA2A401
0xA2A402
RTD 8 Alarm OP
0xA2A601
0xA2A602
RTD 9 Alarm OP
0xA2A801
0xA2A802
RTD 10 Alarm OP
0xA2AA01
0xA2AA02
RTD 11 Alarm OP
0xA2AC01
0xA2AC02
RTD 12 Alarm OP
0xA2AE01
0xA2AE02
RTD 13 Alarm OP
0xA31A01
0xA31A02
Anlg Ip 1 Alrm OP
0xA31C01
0xA31C02
Anlg Ip 2 Alrm OP
0xA31E01
0xA31E02
Anlg Ip 3 Alrm OP
0xA32001
0xA32002
Anlg Ip 4 Alrm OP
0xA38401
0xA38402
Unbal Alarm OP
0xA39008
0xA39010
0xA39040
0xA39080
0xA39401
11-315
FORMAT CODES
Code
FC150
Type
Definition
0xA39402
0xA39801
0xA39802
0xA3A001
0xA3A002
Thermal OL Alrm OP
unsigned 16 bits
11-316
Any Trip
Any Alarm
Y
Y
Any Block
Any PKP
Any OP
Reset
Setpoint Access
10
Security Login
11
Security Status
12
Targets Active
13
In Serv.
14
Test Mode
15
16
17
PB 1
18
PB 2
19
PB 3
20
Output Relay 1
21
Output Relay 2
22
Output Relay 3
23
Output Relay 4
24
Output Relay 5
25
Output Relay 6
26
Critical Fail
27
Comms OK
28
Motor Status
29
30
31
32
33
34
35
36
37
38
39
40
41
42
Y
Y
Code
FORMAT CODES
Type
Definition
43
44
45
46
47
48
49
50
51
Stop
52
Start
65
VFD
66
Percent Differential
67
Overall Differential
68
69
70
71
72
73
74
Y
Y
Y
Y
Y
Y
Y
75
76
Instantaneous Differential
77
78
Thermal Trip
79
Thermal Alarm
80
81
82
Mechanical Jam
83
Undercurrent Alarm
84
Undercurrent Trip
85
Overload
86
Short Circuit
87
88
89
90
Acceleration Time
91
Speed2 Acceleration
92
Underpower Alarm
93
Underpower Trip
94
Transformer Overload
95
96
Y
Y
Y
97
Phase TOC 1
98
Phase TOC 2
99
Phase TOC 3
100
Phase IOC 1
101
Phase IOC 2
Y
Y
11-317
FORMAT CODES
Code
11-318
Type
Definition
102
Phase IOC 3
103
Phase IOC 4
104
Phase IOC 5
105
Phase IOC 6
106
Phase IOC 7
107
Phase IOC 8
108
Ph Dir OC
109
Ntrl TOC 1
110
Ntrl TOC 2
111
Ntrl TOC 3
112
Ntrl IOC 1
113
Ntrl IOC 2
114
Ntrl IOC 3
115
Ntrl IOC 4
116
Ntrl IOC 5
117
Ntrl IOC 6
118
Ntrl Dir OC
119
Gnd TOC 1
120
Gnd TOC 2
121
Gnd TOC 3
122
Gnd IOC 1
123
Gnd IOC 2
124
Gnd IOC 3
125
Gnd IOC 4
126
Gnd IOC 5
127
Gnd IOC 6
Y
Y
Y
Y
Y
Y
128
Gnd Dir OC
129
SGnd TOC 1
131
SGnd IOC 1
133
SGnd Dir OC
134
RGF 1
135
RGF 2
136
RGF 3
137
138
139
140
141
142
143
144
BrokenConductor
145
LoadEncr
Y
Y
Y
146
Thermal Model
147
148
Phase Reversal
151
Aux UV 1
152
Aux UV 2
Code
FORMAT CODES
Type
Definition
156
Aux OV 2
157
Neutral OV 1
159
Neg Seq OV 1
160
Neg Seq OV 2
161
162
163
Dir Pwr 1
164
Dir Pwr 2
165
WattMetric 1
167
UF 1
168
UF 2
169
UF 3
170
UF 4
171
UF 5
172
UF 6
173
OF 1
174
OF 2
175
OF 3
176
OF 4
177
Freq RateOfChng1
178
Freq RateOfChng2
179
Freq RateOfChng3
180
Freq RateOfChng4
181
Freq RateOfChng5
182
Freq RateOfChng6
183
184
185
186
W1 Harmonic Derating
187
W2 Harmonic Derating
188
W3 Harmonic Derating
189
190
191
192
193
TripCoilMon 1
194
TripCoilMon 2
195
TripCoilMon 3
196
CloseCoilMon 1
197
CloseCoilMon 2
198
CloseCoilMon 3
199
200
202
Breaker1 Health
203
Breaker2 Health
204
Breaker3 Health
205
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
11-319
FORMAT CODES
Code
11-320
Type
Definition
206
207
208
209
PF 1
Y
Y
210
PF 2
211
Current Dmd 1
212
Current Dmd 2
Y
Y
213
Current Dmd 3
214
RealPwrDmd
215
ReactivePwrDmd
216
ApparentPwrDmd
217
Pulse Out
218
Digital Counter 1
219
Digital Counter 2
220
Digital Counter 3
221
Digital Counter 4
222
Digital Counter 5
223
Digital Counter 6
224
Digital Counter 7
225
Digital Counter 8
226
Digital Counter 9
227
Digital Counter 10
228
Digital Counter 11
229
Digital Counter 12
230
Digital Counter 13
231
Digital Counter 14
232
Digital Counter 15
233
Digital Counter 16
234
Harmonic Detection 1
235
Harmonic Detection 2
236
Harmonic Detection 3
237
Harmonic Detection 4
238
Harmonic Detection 5
239
Harmonic Detection 6
240
Start Inhibit
241
242
Group 1
243
Group 2
244
Group 3
245
Group 4
246
Group 5
247
Group 6
248
Thermal Inhibit
249
250
251
Restart Delay
252
Code
FORMAT CODES
Type
Definition
253
254
Local Mode
255
Open BKR 1
256
Open BKR 2
258
Close BKR 1
259
Close BKR 2
261
Trip Bus 1
262
Trip Bus 2
263
Trip Bus 3
264
Trip Bus 4
265
Trip Bus 5
266
Trip Bus 6
267
BKR Fail 1
268
BKR Fail 2
269
BKR Fail 3
270
Sync Check 1
272
273
CLP 1
275
UV Restore
276
UF Restore
277
Bus Transfer
278
Transfer Initiated
279
AR1
280
281
282
287
VTFF 1
289
NV Latch 1
290
NV Latch 2
291
NV Latch 3
292
NV Latch 4
293
NV Latch 5
294
NV Latch 6
295
NV Latch 7
296
NV Latch 8
297
NV Latch 9
298
NV Latch 10
299
NV Latch 11
300
NV Latch 12
301
NV Latch 13
302
NV Latch 14
303
NV Latch 15
304
NV Latch 16
305
FlexElement 1
306
FlexElement 2
307
FlexElement 3
308
FlexElement 4
Y
Y
Y
Y
Y
Y
Y
Y
Y
11-321
FORMAT CODES
Code
11-322
Type
Definition
309
FlexElement 5
310
FlexElement 6
311
FlexElement 7
312
FlexElement 8
313
Hot RTD
314
RTD 1 Trip
315
RTD 2 Trip
316
RTD 3 Trip
317
RTD 4 Trip
318
RTD 5 Trip
319
RTD 6 Trip
320
RTD 7 Trip
321
RTD 8 Trip
322
RTD 9 Trip
323
RTD 10 Trip
324
RTD 11 Trip
325
RTD 12 Trip
326
RTD 13 Trip
332
RTD 1 Alarm
333
RTD 2 Alarm
334
RTD 3 Alarm
335
RTD 4 Alarm
336
RTD 5 Alarm
337
RTD 6 Alarm
338
RTD 7 Alarm
339
RTD 8 Alarm
340
RTD 9 Alarm
341
RTD 10 Alarm
342
RTD 11 Alarm
343
RTD 12 Alarm
344
RTD 13 Alarm
386
387
388
389
398
399
400
401
410
Fault Locator
411
Data Logger
412
Fast Underfrequency 1
413
Fast Underfrequency 2
414
Fast Underfrequency 3
415
Fast Underfrequency 4
416
Fast Underfrequency 5
417
Fast Underfrequency 6
Code
FC156
FC157
FC161
FORMAT CODES
Type
Definition
418
Fast Underfrequency 7
419
Fast Underfrequency 8
420
Arc Flash 1
421
423
424
438
439
441
Generator Status
442
Running Hours
443
444
445
446
447
448
449
450
451
452
Inadvertent Energization
453
Offline Overcurrent
454
455
Sequential Shutdown
456
457
458
459
460
461
462
463
464
Out-of-Step
465
466
467
DGA Alarm
468
Y
Y
Y
Y
unsigned 16 bits
Directional Polarizing
Voltage
Current
Dual
unsigned 16 bits
LED Colour
Off
Red
Green
Orange
unsigned 16 bits
OC Curve Selection
11-323
FORMAT CODES
Code
FC161A
FC161B
FC161C
FC161D
11-324
Type
Definition
Definite Time
IEC Curve A
IEC Curve B
10
IEC Curve C
11
12
13
14
IAC Inverse
15
16
FlexCurve A
17
FlexCurve B
18
FlexCurve C
19
FlexCurve D
20
I2t
21
I4t
unsigned 16 bits
Definite Time
16
FlexCurve A
17
FlexCurve B
18
FlexCurve C
Y
Y
19
FlexCurve D
unsigned 16 bits
Inverse
Definite Time
16
FlexCurve A
17
FlexCurve B
18
FlexCurve C
19
FlexCurve D
unsigned 16 bits
16
FlexCurve A
17
FlexCurve B
18
FlexCurve C
19
FlexCurve D
22
IEC
23
Motor
unsigned 16 bits
Definite Time
16
FlexCurve A
17
FlexCurve B
18
FlexCurve C
19
FlexCurve D
Code
FC161E
FC164
FC164A
FC165
FC166
FC169
FC170
FC171
FORMAT CODES
Type
Definition
24
Inverse A
25
Inverse B
26
Inverse C
unsigned 16 bits
16
FlexCurve A
17
FlexCurve B
18
FlexCurve C
19
FlexCurve D
22
IEC
unsigned 16 bits
Overcurrent Direction
Disabled
Forward
Reverse
unsigned 16 bits
Power Direction
Forward
Reverse
unsigned 16 bits
Simulation Status
Disabled
Prefault State
Fault State
Postfault State
unsigned 16 bits
Instantaneous
Timed
unsigned 16 bits
Month
Not Set
January
February
March
April
May
June
July
August
September
10
October
11
November
12
December
unsigned 16 bits
Count of Week
Not Set
1st
2nd
3rd
4th
Last
unsigned 16 bits
Weekdays
Not Set
11-325
FORMAT CODES
Code
FC176
FC177
FC181
FC182
FC183
FC186
FC187
FC191
11-326
Type
Definition
SUN
MON
TUE
WED
THU
FRI
SAT
unsigned 16 bits
Auxiliary VT Connection
Vab VT
Vbc VT
Vca VT
Van VT
Vbn VT
Vcn VT
Vn
Auxiliary 52a
Auxiliary 52b
unsigned 16 bits
Overwrite
unsigned 16 bits
Protected
unsigned 16 bits
128 /c
64 /c
32 /c
16 /c
Y
Y
8 /c
unsigned 16 bits
1 Cycle
1 Second
30 Seconds
1 Minute
15 Minutes
30 Minutes
1 Hour
unsigned 16 bits
Disabled
Continuous
Triggered
unsigned 16 bits
Sample
Max
Min
Mean
unsigned 32 bits
0x00000001
Remote Input 1
0x00000002
Remote Input 2
Code
FC192
FORMAT CODES
Type
Definition
0x00000004
Remote Input 3
0x00000008
Remote Input 4
0x00000010
Remote Input 5
0x00000020
Remote Input 6
0x00000040
Remote Input 7
0x00000080
Remote Input 8
0x00000100
Remote Input 9
0x00000200
Remote Input 10
0x00000400
Remote Input 11
0x00000800
Remote Input 12
0x00001000
Remote Input 13
0x00002000
Remote Input 14
0x00004000
Remote Input 15
0x00008000
Remote Input 16
0x00010000
Remote Input 17
0x00020000
Remote Input 18
0x00040000
Remote Input 19
0x00080000
Remote Input 20
0x00100000
Remote Input 21
0x00200000
Remote Input 22
0x00400000
Remote Input 23
0x00800000
Remote Input 24
0x01000000
Remote Input 25
0x02000000
Remote Input 26
0x04000000
Remote Input 27
0x08000000
Remote Input 28
0x10000000
Remote Input 29
0x20000000
Remote Input 30
0x40000000
Remote Input 31
0x80000000
Remote Input 32
unsigned 32 bits
0x00000001
Remote Output 1
0x00000002
Remote Output 2
0x00000004
Remote Output 3
0x00000008
Remote Output 4
0x00000010
Remote Output 5
0x00000020
Remote Output 6
0x00000040
Remote Output 7
0x00000080
Remote Output 8
0x00000100
Remote Output 9
0x00000200
Remote Output 10
0x00000400
Remote Output 11
0x00000800
Remote Output 12
0x00001000
Remote Output 13
0x00002000
Remote Output 14
0x00004000
Remote Output 15
0x00008000
Remote Output 16
11-327
FORMAT CODES
Code
FC194
11-328
Type
Definition
0x00010000
Remote Output 17
0x00020000
Remote Output 18
0x00040000
Remote Output 19
0x00080000
Remote Output 20
0x00100000
Remote Output 21
0x00200000
Remote Output 22
0x00400000
Remote Output 23
0x00800000
Remote Output 24
0x01000000
Remote Output 25
0x02000000
Remote Output 26
0x04000000
Remote Output 27
0x08000000
Remote Output 28
0x10000000
Remote Output 29
0x20000000
Remote Output 30
0x40000000
Remote Output 31
0x80000000
Remote Output 32
unsigned 32 bits
0x00000001
Contact Input 1
0x00000002
Contact Input 2
0x00000004
Contact Input 3
0x00000008
Contact Input 4
0x00000010
Contact Input 5
0x00000020
Contact Input 6
0x00000040
Contact Input 7
0x00000080
Contact Input 8
0x00000100
Contact Input 9
0x00000200
Contact Input 10
0x00000400
Contact Input 11
0x00000800
Contact Input 12
0x00001000
Contact Input 13
0x00002000
Contact Input 14
0x00004000
Contact Input 15
0x00008000
Contact Input 16
0x00010000
Contact Input 17
0x00020000
Contact Input 18
0x00040000
Contact Input 19
0x00080000
Contact Input 20
0x00100000
Contact Input 21
0x00200000
Contact Input 22
0x00400000
Contact Input 23
0x00800000
Contact Input 24
0x01000000
Contact Input 25
0x02000000
Contact Input 26
0x04000000
Contact Input 27
0x08000000
Contact Input 28
0x10000000
Contact Input 29
0x20000000
Contact Input 30
Code
FC198
FORMAT CODES
Type
Definition
0x40000000
Contact Input 31
0x80000000
Contact Input 32
unsigned 32 bits
0x00000004
Output Relay 3
0x00000008
Output Relay 4
0x00000010
Output Relay 5
0x00000020
Output Relay 6
0x00000040
Output Relay 7
unsigned 32 bits
Relay Operation
0x00000004
Relay 3
0x00000008
Relay 4
0x00000010
Relay 5
0x00000020
Relay 6
0x00000040
Relay 7
unsigned 32 bits
0x00000001
0x00000002
0x00000004
0x00000008
0x00000010
0x00000020
0x00000040
0x00000080
0x00000100
0x00000200
0x00000400
0x00000800
0x00001000
0x00002000
0x00004000
0x00008000
0x00010000
0x00020000
0x00040000
0x00080000
0x00100000
0x00200000
0x00400000
0x00800000
0x01000000
FC198A
Each bit corresponds to a
particular output relay, and
uses format FC126A
FC198C
Each bit corresponds to a
particular output relay, and
uses format FC126A
11-329
FORMAT CODES
Code
FC198D
Type
Definition
0x02000000
0x04000000
0x08000000
0x10000000
0x20000000
0x40000000
0x80000000
unsigned 32 bits
0x00000001
0x00000002
0x00000004
0x00000008
0x00000010
0x00000020
0x00000040
0x00000080
0x00000100
0x00000200
0x00000400
0x00000800
0x00001000
0x00002000
0x00004000
0x00008000
0x00010000
0x00020000
0x00040000
0x00080000
0x00100000
0x00200000
0x00400000
0x00800000
0x01000000
0x02000000
0x04000000
0x08000000
0x10000000
0x20000000
0x40000000
0x80000000
unsigned 32 bits
0x00000001
FC198E
Each bit corresponds to a
particular output relay, and
uses format FC126A
11-330
Code
FC198F
FORMAT CODES
Type
Definition
0x00000002
0x00000004
0x00000008
0x00000010
0x00000020
0x00000040
0x00000080
0x00000100
0x00000200
0x00000400
0x00000800
0x00001000
0x00002000
0x00004000
0x00008000
0x00010000
0x00020000
0x00040000
0x00080000
0x00100000
0x00200000
0x00400000
0x00800000
0x01000000
0x02000000
0x04000000
0x08000000
0x10000000
0x20000000
0x40000000
0x80000000
unsigned 32 bits
Off
0x00000001
Relay 1
0x00000002
Relay 2
0x00000004
Relay 3
0x00000008
Relay 4
0x00000010
Relay 5
0x00000020
Relay 6
0x00000040
Relay 7
0x00000080
Relay 8
0x00000100
Relay 9
0x00000200
Relay 10
0x00000400
Relay 11
0x00000800
Relay 12
0x00001000
Relay 13
0x00002000
Relay 14
11-331
FORMAT CODES
Code
FC198G
11-332
Type
Definition
0x00004000
Relay 15
0x00008000
Relay 16
0x00010000
Relay 17
0x00020000
Relay 18
0x00040000
Relay 19
0x00080000
Relay 20
0x00100000
Relay 21
0x00200000
Relay 22
0x00400000
Relay 23
0x00800000
Relay 24
0x01000000
Relay 25
0x02000000
Relay 26
0x04000000
Relay 27
0x08000000
Relay 28
0x10000000
Relay 29
0x20000000
Relay 30
0x40000000
Relay 31
0x80000000
Relay 32
unsigned 32 bits
Off
0x00000001
Relay 1
0x00000002
Relay 2
0x00000004
Relay 3
0x00000008
Relay 4
0x00000010
Relay 5
0x00000020
Relay 6
0x00000040
Relay 7
0x00000080
Relay 8
0x00000100
Relay 9
0x00000200
Relay 10
0x00000400
Relay 11
0x00000800
Relay 12
0x00001000
Relay 13
0x00002000
Relay 14
0x00004000
Relay 15
0x00008000
Relay 16
0x00010000
Relay 17
0x00020000
Relay 18
0x00040000
Relay 19
0x00080000
Relay 20
0x00100000
Relay 21
0x00200000
Relay 22
0x00400000
Relay 23
0x00800000
Relay 24
0x01000000
Relay 25
0x02000000
Relay 26
0x04000000
Relay 27
Code
FC198H
FORMAT CODES
Type
Definition
0x08000000
Relay 28
0x10000000
Relay 29
0x20000000
Relay 30
0x40000000
Relay 31
0x80000000
Relay 32
unsigned 32 bits
0x00000001
Output Relay 1
0x00000002
Output Relay 2
0x00000004
Output Relay 3
0x00000008
Output Relay 4
0x00000010
Output Relay 5
0x00000020
Output Relay 6
0x00000040
Output Relay 7
0x00000080
Output Relay 8
0x00000100
Output Relay 9
0x00000200
Output Relay 10
0x00000400
Output Relay 11
0x00000800
Output Relay 12
0x00001000
Output Relay 13
0x00002000
Output Relay 14
0x00004000
Output Relay 15
0x00008000
Output Relay 16
0x00010000
Output Relay 17
0x00020000
Output Relay 18
0x00040000
Output Relay 19
0x00080000
Output Relay 20
0x00100000
Output Relay 21
0x00200000
Output Relay 22
0x00400000
Output Relay 23
0x00800000
Output Relay 24
0x01000000
Output Relay 25
0x02000000
Output Relay 26
0x04000000
Output Relay 27
0x08000000
Output Relay 28
0x10000000
Output Relay 29
0x20000000
Output Relay 30
0x40000000
Output Relay 31
FC198I
0x80000000
Output Relay 32
unsigned 32 bits
0x00000001
0x00000002
0x00000004
11-333
FORMAT CODES
Code
FC199
FC208
FC209
FC210
FC211
11-334
Type
Definition
0x00000008
0x00000010
0x00000020
0x00000040
0x00000080
0x00000100
0x00000200
0x00000400
0x00000800
0x00001000
0x00002000
0x00004000
0x00008000
0x00010000
0x00020000
0x00040000
0x00080000
0x00100000
0x00200000
0x00400000
0x00800000
0x01000000
0x02000000
0x04000000
0x08000000
0x10000000
0x20000000
0x40000000
0x80000000
unsigned 16 bits
Self-Reset
Latched
unsigned 16 bits
Non-Failsafe
Y
Y
Failsafe
unsigned 16 bits
Modbus
IEC60870-5-103
DNP 3.0
unsigned 16 bits
9600 baud
19200 baud
38400 baud
57600 baud
115200 baud
unsigned 16 bits
RS 485 Parity
None
Code
FC212
FC217
FC218
FC219
FC220
FC226
FC228
FC229
FC230
FORMAT CODES
Type
Definition
Odd
Even
unsigned 16 bits
unsigned 16 bits
Ethernet Duplicate
Discard
Accept
unsigned 16 bits
Ethernet Mode
Full-Duplex
unsigned 16 bits
Independent
LLA
PRP
unsigned 16 bits
None
DC Shift
Amplitude Mod.
unsigned 16 bits
None
WPA2-PSK
unsigned 16 bits
61850 Status
0x0001
Comms NV OK
0x0002
Comms NV Done
0x0004
Comms V OK
0x0008
Comms V Done
0x0010
Main NV OK
0x0020
Main NV Done
0x0040
Main V OK
0x0080
Main V Done
0x0100
0x0200
R. Default CID
0x0400
0x0800
unsigned 16 bits
/ 0.001
/ 0.01
/ 0.1
/1
/ 10
/ 100
/ 1000
/ 10000
/ 100000
unsigned 16 bits
Off
Virtual Input 1
11-335
FORMAT CODES
Code
FC231
FC232
FC233
11-336
Type
Definition
Virtual Input 2
Virtual Input 3
Virtual Input 4
Virtual Input 5
Virtual Input 6
Virtual Input 7
Virtual Input 8
Virtual Input 9
10
Virtual Input 10
11
Virtual Input 11
12
Virtual Input 12
13
Virtual Input 13
14
Virtual Input 14
15
Virtual Input 15
16
Virtual Input 16
17
Virtual Input 17
18
Virtual Input 18
19
Virtual Input 19
20
Virtual Input 20
21
Virtual Input 21
22
Virtual Input 22
23
Virtual Input 23
24
Virtual Input 24
25
Virtual Input 25
26
Virtual Input 26
27
Virtual Input 27
28
Virtual Input 28
29
Virtual Input 29
30
Virtual Input 30
31
Virtual Input 31
32
Virtual Input 32
33
FC: Reset
34
35
36
37
38
39
unsigned 16 bits
unsigned 16 bits
unsigned 16 bits
Code
FC234
FC235
FC236
FC237
FC238
FC239
FC239A
FC240
FORMAT CODES
Type
Definition
unsigned 16 bits
10
10
unsigned 16 bits
unsigned 16 bits
unsigned 16 bits
unsigned 16 bits
unsigned 16 bits
None
Network-TCP
Network-UDP
unsigned 16 bits
None
Network-TCP
unsigned 32 bits
No Error
0x00000001
0x00000002
0x00000004
0x00000008
0x00000010
0x00000020
0x00000040
0x00000080
11-337
FORMAT CODES
Code
FC240A
11-338
Type
Definition
0x00000100
0x00000200
0x00000400
0x00000800
FP Serial# Invalid
0x00001000
0x00002000
Calibration Error
0x00004000
RTC Error
0x00010000
FLASH Error
0x00020000
EEPROM Error
0x00040000
0x00200000
0x00400000
0x00800000
0x04000000
unsigned 32 bits
No Error
0x00000001
0x00000002
0x00000004
0x00000008
0x00000010
0x00000020
0x00000040
0x00000080
0x00000100
0x00000200
0x00000400
0x00000800
FP Serial# Invalid
0x00001000
0x00002000
0x00004000
RTC Error
0x00008000
COMM Error #1
0x00010000
FLASH Error
0x00020000
COMM Error #2
0x00040000
0x00080000
0x00100000
0x00200000
0x00400000
0x00800000
0x01000000
Version Mismatch
0x02000000
0x04000000
SPI Error
0x08000000
Slot B IO Error
0x10000000
Slot C IO Error
0x20000000
IRIG-B Error
0x40000000
Code
FC241
FORMAT CODES
Type
Definition
0x80000000
SelfTestFWUpdate
unsigned 32 bits
0x0000
Off
0x200
CI 1 On
0x201
CI 2 On
0x202
CI 3 On
0x203
CI 4 On
0x204
CI 5 On
0x205
CI 6 On
0x206
CI 7 On
0x207
CI 8 On
0x208
CI 9 On
0x209
CI 10 On
0x20A
CI 11 On
0x20B
CI 12 On
0x20C
CI 13 On
0x20D
CI 14 On
0x20E
CI 15 On
0x20F
CI 16 On
0x210
CI 17 On
0x211
CI 18 On
0x212
CI 19 On
0x213
CI 20 On
0x214
CI 21 On
0x215
CI 22 On
0x216
CI 23 On
0x217
CI 24 On
0x218
CI 25 On
0x219
CI 26 On
0x21A
CI 27 On
0x21B
CI 28 On
0x21C
CI 29 On
0x21D
CI 30 On
0x21E
CI 31 On
0x21F
CI 32 On
0x220
CI 33 On
0x221
CI 34 On
0x222
CI 35 On
0x223
CI 36 On
0x224
CI 37 On
0x225
CI 38 On
0x226
CI 39 On
0x227
CI 40 On
0x228
CI 41 On
0x229
CI 42 On
0x22A
CI 43 On
0x22B
CI 44 On
11-339
FORMAT CODES
Code
11-340
Type
Definition
0x22C
CI 45 On
0x22D
CI 46 On
0x22E
CI 47 On
0x22F
CI 48 On
0x230
CI 49 On
0x231
CI 50 On
0x232
CI 51 On
0x233
CI 52 On
0x234
CI 53 On
0x235
CI 54 On
0x236
CI 55 On
0x237
CI 56 On
0x238
CI 57 On
0x239
CI 58 On
0x23A
CI 59 On
0x23B
CI 60 On
0x23C
CI 61 On
0x23D
CI 62 On
0x23E
CI 63 On
0x23F
CI 64 On
0x240
CI 65 On
0x241
CI 66 On
0x242
CI 67 On
0x243
CI 68 On
0x244
CI 69 On
0x245
CI 70 On
0x246
CI 71 On
0x247
CI 72 On
0x248
CI 73 On
0x249
CI 74 On
0x24A
CI 75 On
0x24B
CI 76 On
0x24C
CI 77 On
0x24D
CI 78 On
0x24E
CI 79 On
0x24F
CI 80 On
0x250
CI 81 On
0x251
CI 82 On
0x252
CI 83 On
0x253
CI 84 On
0x254
CI 85 On
0x255
CI 86 On
0x256
CI 87 On
0x257
CI 88 On
0x258
CI 89 On
0x259
CI 90 On
0x25A
CI 91 On
Code
FORMAT CODES
Type
Definition
0x25B
CI 92 On
0x25C
CI 93 On
0x25D
CI 94 On
0x25E
CI 95 On
0x25F
CI 96 On
0x300
CI 1 Off
0x301
CI 2 Off
0x302
CI 3 Off
0x303
CI 4 Off
0x304
CI 5 Off
0x305
CI 6 Off
0x306
CI 7 Off
0x307
CI 8 Off
0x308
CI 9 Off
0x309
CI 10 Off
0x30A
CI 11 Off
0x30B
CI 12 Off
0x30C
CI 13 Off
0x30D
CI 14 Off
0x30E
CI 15 Off
0x30F
CI 16 Off
0x310
CI 17 Off
0x311
CI 18 Off
0x312
CI 19 Off
0x313
CI 20 Off
0x314
CI 21 Off
0x315
CI 22 Off
0x316
CI 23 Off
0x317
CI 24 Off
0x318
CI 25 Off
0x319
CI 26 Off
0x31A
CI 27 Off
0x31B
CI 28 Off
0x31C
CI 29 Off
0x31D
CI 30 Off
0x31E
CI 31 Off
0x31F
CI 32 Off
0x320
CI 33 Off
0x321
CI 34 Off
0x322
CI 35 Off
0x323
CI 36 Off
0x324
CI 37 Off
0x325
CI 38 Off
0x326
CI 39 Off
0x327
CI 40 Off
0x328
CI 41 Off
0x329
CI 42 Off
11-341
FORMAT CODES
Code
11-342
Type
Definition
0x32A
CI 43 Off
0x32B
CI 44 Off
0x32C
CI 45 Off
0x32D
CI 46 Off
0x32E
CI 47 Off
0x32F
CI 48 Off
0x330
CI 49 Off
0x331
CI 50 Off
0x332
CI 51 Off
0x333
CI 52 Off
0x334
CI 53 Off
0x335
CI 54 Off
0x336
CI 55 Off
0x337
CI 56 Off
0x338
CI 57 Off
0x339
CI 58 Off
0x33A
CI 59 Off
0x33B
CI 60 Off
0x33C
CI 61 Off
0x33D
CI 62 Off
0x33E
CI 63 Off
0x33F
CI 64 Off
0x340
CI 65 Off
0x341
CI 66 Off
0x342
CI 67 Off
0x343
CI 68 Off
0x344
CI 69 Off
0x345
CI 70 Off
0x346
CI 71 Off
0x347
CI 72 Off
0x348
CI 73 Off
0x349
CI 74 Off
0x34A
CI 75 Off
0x34B
CI 76 Off
0x34C
CI 77 Off
0x34D
CI 78 Off
0x34E
CI 79 Off
0x34F
CI 80 Off
0x350
CI 81 Off
0x351
CI 82 Off
0x352
CI 83 Off
0x353
CI 84 Off
0x354
CI 85 Off
0x355
CI 86 Off
0x356
CI 87 Off
0x357
CI 88 Off
0x358
CI 89 Off
Code
FORMAT CODES
Type
Definition
0x359
CI 90 Off
0x35A
CI 91 Off
0x35B
CI 92 Off
0x35C
CI 93 Off
0x35D
CI 94 Off
0x35E
CI 95 Off
0x35F
CI 96 Off
0x400
VI 1 On
0x401
VI 2 On
0x402
VI 3 On
0x403
VI 4 On
0x404
VI 5 On
0x405
VI 6 On
0x406
VI 7 On
0x407
VI 8 On
0x408
VI 9 On
0x409
VI 10 On
0x40A
VI 11 On
0x40B
VI 12 On
0x40C
VI 13 On
0x40D
VI 14 On
0x40E
VI 15 On
0x40F
VI 16 On
0x410
VI 17 On
0x411
VI 18 On
0x412
VI 19 On
0x413
VI 20 On
0x414
VI 21 On
0x415
VI 22 On
0x416
VI 23 On
0x417
VI 24 On
0x418
VI 25 On
0x419
VI 26 On
0x41A
VI 27 On
0x41B
VI 28 On
0x41C
VI 29 On
0x41D
VI 30 On
0x41E
VI 31 On
0x41F
VI 32 On
0x500
VI 1 Off
0x501
VI 2 Off
0x502
VI 3 Off
0x503
VI 4 Off
0x504
VI 5 Off
0x505
VI 6 Off
0x506
VI 7 Off
0x507
VI 8 Off
11-343
FORMAT CODES
Code
11-344
Type
Definition
0x508
VI 9 Off
0x509
VI 10 Off
0x50A
VI 11 Off
0x50B
VI 12 Off
0x50C
VI 13 Off
0x50D
VI 14 Off
0x50E
VI 15 Off
0x50F
VI 16 Off
0x510
VI 17 Off
0x511
VI 18 Off
0x512
VI 19 Off
0x513
VI 20 Off
0x514
VI 21 Off
0x515
VI 22 Off
0x516
VI 23 Off
0x517
VI 24 Off
0x518
VI 25 Off
0x519
VI 26 Off
0x51A
VI 27 Off
0x51B
VI 28 Off
0x51C
VI 29 Off
0x51D
VI 30 Off
0x51E
VI 31 Off
0x51F
VI 32 Off
0xE00
RI 1 On
0xE01
RI 2 On
0xE02
RI 3 On
0xE03
RI 4 On
0xE04
RI 5 On
0xE05
RI 6 On
0xE06
RI 7 On
0xE07
RI 8 On
0xE08
RI 9 On
0xE09
RI 10 On
0xE0A
RI 11 On
0xE0B
RI 12 On
0xE0C
RI 13 On
0xE0D
RI 14 On
0xE0E
RI 15 On
0xE0F
RI 16 On
0xE10
RI 17 On
0xE11
RI 18 On
0xE12
RI 19 On
0xE13
RI 20 On
0xE14
RI 21 On
0xE15
RI 22 On
0xE16
RI 23 On
Code
FC252
FC253
FORMAT CODES
Type
Definition
0xE17
RI 24 On
0xE18
RI 25 On
0xE19
RI 26 On
0xE1A
RI 27 On
0xE1B
RI 28 On
0xE1C
RI 29 On
0xE1D
RI 30 On
0xE1E
RI 31 On
0xE1F
RI 32 On
0xF00
RI 1 Off
0xF01
RI 2 Off
0xF02
RI 3 Off
0xF03
RI 4 Off
0xF04
RI 5 Off
0xF05
RI 6 Off
0xF06
RI 7 Off
0xF07
RI 8 Off
0xF08
RI 9 Off
0xF09
RI 10 Off
0xF0A
RI 11 Off
0xF0B
RI 12 Off
0xF0C
RI 13 Off
0xF0D
RI 14 Off
0xF0E
RI 15 Off
0xF0F
RI 16 Off
0xF10
RI 17 Off
0xF11
RI 18 Off
0xF12
RI 19 Off
0xF13
RI 20 Off
0xF14
RI 21 Off
0xF15
RI 22 Off
0xF16
RI 23 Off
0xF17
RI 24 Off
0xF18
RI 25 Off
0xF19
RI 26 Off
0xF1A
RI 27 Off
0xF1B
RI 28 Off
0xF1C
RI 29 Off
0xF1D
RI 30 Off
0xF1E
RI 31 Off
0xF1F
RI 32 Off
unsigned 16 bits
Security Users
Administrator
Operator
unsigned 16 bits
Trend
Decreasing
Increasing
11-345
FORMAT CODES
Code
FC254
FC255
FC256
FC258
FC259
FC260
FC261
FC261A
FC262
FC263
FC264
11-346
Type
Definition
Bi-directional
unsigned 16 bits
Measurement Type
Blk Interval
Exponential
Rolling Dmd
unsigned 16 bits
5 min
10 min
15 min
20 min
30 min
unsigned 16 bits
Phasor
RMS
unsigned 16 bits
CT Secondary
1:00 AM
5:00 AM
unsigned 16 bits
Same
Reverse
unsigned 16 bits
Mode
Phase to Ground
Phase to Phase
unsigned 16 bits
Any One
Any Two
Y
Y
All Three
unsigned 16 bits
Any One
Any Two
All Three
Average
unsigned 16 bits
Disabled
Retrip
Latched Alarm
Alarm
Configurable
unsigned 16 bits
Current
52b
unsigned 16 bits
Breaker Status
State Unknown
Opened
Closed
Disconnected
Code
FC265
FC266
FC267
FC268
FC269
FC270
FC271
FC272
FORMAT CODES
Type
Definition
Not Configured
unsigned 16 bits
TOC Reset
Instantaneous
Timed
unsigned 32 bits
0x0000
Off
0x200
Contact Input 1
0x201
Contact Input 2
0x202
Contact Input 3
0x203
Contact Input 4
0x204
Contact Input 5
0x205
Contact Input 6
0x206
Contact Input 7
0x207
Contact Input 8
0x208
Contact Input 9
0x209
Contact Input 10
0x20A
Contact Input 11
0x20B
Contact Input 12
0x20C
Contact Input 13
0x20D
Contact Input 14
unsigned 16 bits
Supervision Function
Disabled
Lockout
Alarm
unsigned 16 bits
Miles
Km
unsigned 16 bits
VT Substitution
None
I0
V0
unsigned 16 bits
Type Of Fault
N/A
AG
BG
CG
AB
BC
CA
ABG
CAG
BCG
Y
Y
10
ABC
unsigned 16 bits
Reset-Dominant
Set-Dominant
unsigned 16 bits
11-347
FORMAT CODES
Code
FC272A
FC273
11-348
Type
Definition
Calculated V0
Measured VX
unsigned 16 bits
Calculated VN
Measured VX
unsigned 16 bits
FlexAnalog Parameters
Off
31270
J1 Ia
31272
J1 Ib
31274
J1 Ic
31276
J1 Ig
31278
J1 In
31280
J1 Ia RMS
31282
J1 Ib RMS
31284
J1 Ic RMS
31286
J1 Ig RMS
31288
J1 In RMS
31290
J1 Ia Angle
31291
J1 Ib Angle
31292
J1 Ic Angle
31293
J1 Ig Angle
31294
J1 In Angle
31295
J1 I AVG
31297
J1 I_0
31299
J1 I_1
31301
J1 I_2
31303
J1 I_0 Angle
31304
J1 I_1 Angle
31305
J1 I_2 Angle
31306
J1 Igd
31308
J1 Igd Angle
31309
J1 Load
31320
K1 Ia
31322
K1 Ib
31324
K1 Ic
31326
K1 Ig
31328
K1 In
31330
K1 Ia RMS
31332
K1 Ib RMS
31334
K1 Ic RMS
31336
K1 Ig RMS
31338
K1 In RMS
31340
K1 Ia Angle
31341
K1 Ib Angle
31342
K1 Ic Angle
31343
K1 Ig Angle
31344
K1 In Angle
Code
FORMAT CODES
Type
Definition
31345
K1 I AVG
31347
K1 I_0
31349
K1 I_1
31351
K1 I_2
31353
K1 I_0 Angle
31354
K1 I_1 Angle
31355
K1 I_2 Angle
31356
K1 Igd
31358
K1 Igd Angle
31359
K1 Load
31370
K2 Ia
31372
K2 Ib
31374
K2 Ic
31376
K2 Ig
31378
K2 In
31380
K2 Ia RMS
31382
K2 Ib RMS
31384
K2 Ic RMS
31386
K2 Ig RMS
31388
K2 In RMS
31390
K2 Ia Angle
31391
K2 Ib Angle
31392
K2 Ic Angle
31393
K2 Ig Angle
31394
K2 In Angle
31395
K2 I AVG
31397
K2 I_0
31399
K2 I_1
31401
K2 I_2
31403
K2 I_0 Angle
31404
K2 I_1 Angle
31405
K2 I_2 Angle
31406
K2 Igd
31408
K2 Igd Angle
31409
K2 Load
31430
J2 Van
31432
J2 Vbn
31434
J2 Vcn
31436
J2 Vab
31438
J2 Vbc
31440
J2 Vca
31442
J2 Vn
31444
J2 Vaux
31446
J2 Van RMS
31448
J2 Vbn RMS
31450
J2 Vcn RMS
31452
J2 Vab RMS
11-349
FORMAT CODES
Code
11-350
Type
Definition
31454
J2 Vbc RMS
31456
J2 Vca RMS
31458
J2 Vn RMS
31460
J2 Vaux RMS
31462
J2 Van Angle
31463
J2 Vbn Angle
31464
J2 Vcn Angle
31465
J2 Vab Angle
31466
J2 Vbc Angle
31467
J2 Vca Angle
31468
J2 Vn Angle
31469
J2 Vaux Angle
31470
J2 V AVG L-L
31472
J2 V AVG L-N
31474
J2 V0
31476
J2 V1
31478
J2 V2
31480
J2 V0 Angle
31481
J2 V1 Angle
31482
J2 V2 Angle
31493
K2 Van
31495
K2 Vbn
31497
K2 Vcn
31499
K2 Vab
31501
K2 Vbc
31503
K2 Vca
31505
K2 Vn
31507
K2 Vaux
31509
K2 Van RMS
31511
K2 Vbn RMS
31513
K2 Vcn RMS
31515
K2 Vab RMS
31517
K2 Vbc RMS
31519
K2 Vca RMS
31521
K2 Vn RMS
31523
K2 Vaux RMS
31525
K2 Van Angle
31526
K2 Vbn Angle
31527
K2 Vcn Angle
31528
K2 Vab Angle
31529
K2 Vbc Angle
31530
K2 Vca Angle
31531
K2 Vn Angle
31532
K2 Vaux Angle
31533
K2 V AVG L-L
31535
K2 V AVG L-N
31537
K2 V0
Code
FORMAT CODES
Type
Definition
31539
K2 V1
31541
K2 V2
31543
K2 V0 Angle
31544
K2 V1 Angle
31545
K2 V2 Angle
31571
Frequency
Y
Y
31610
J1 Phase A THD
31611
J1 Phase B THD
31612
J1 Phase C THD
31613
31614
31615
31616
31617
31618
31619
31620
31621
31622
31623
31624
31625
31626
31627
31628
31629
31630
31631
31632
31633
31634
31635
31636
31637
31638
31639
31640
31641
31642
31643
31644
31645
31646
31647
31648
31649
31650
11-351
FORMAT CODES
Code
11-352
Type
Definition
31651
31652
31653
31654
31655
31656
31657
31658
31659
31660
31661
31662
31663
31664
31665
31666
31667
31668
31669
31670
31671
31672
31673
31674
31675
31676
31677
31678
31679
31680
31681
31682
31683
31684
31695
J2 Phase A THD
31696
J2 Phase B THD
31697
J2 Phase C THD
31698
31699
31700
31701
31702
31703
31704
31705
31706
31707
Code
FORMAT CODES
Type
Definition
31708
31709
31710
31711
31712
31713
31714
31715
31716
31717
31718
31719
31720
31721
31722
31723
31724
31725
31726
31727
31728
31729
31730
31731
31732
31733
31734
31735
31736
31737
31738
31739
31740
31741
31742
31743
31744
31745
31746
31747
31748
31749
31750
31751
31752
31753
31754
11-353
FORMAT CODES
Code
11-354
Type
Definition
31755
31756
31757
31758
31759
31760
31761
31762
31763
31764
31765
31766
31767
31768
31769
31780
K1 Phase A THD
31781
K1 Phase B THD
31782
K1 Phase C THD
31783
31784
31785
31786
31787
31788
31789
31790
31791
31792
31793
31794
31795
31796
31797
31798
31799
31800
31801
31802
31803
31804
31805
31806
31807
31808
31809
31810
31811
Code
FORMAT CODES
Type
Definition
31812
31813
31814
31815
31816
31817
31818
31819
31820
31821
31822
31823
31824
31825
31826
31827
31828
31829
31830
31831
31832
31833
31834
31835
31836
31837
31838
31839
31840
31841
31842
31843
31844
31845
31846
31847
31848
31849
31850
31851
31852
31853
31854
31865
K2 Phase A THD
31866
K2 Phase B THD
31867
K2 Phase C THD
31868
11-355
FORMAT CODES
Code
11-356
Type
Definition
31869
31870
31871
31872
31873
31874
31875
31876
31877
31878
31879
31880
31881
31882
31883
31884
31885
31886
31887
31888
31889
31890
31891
31892
31893
31894
31895
31896
31897
31898
31899
31900
31901
31902
31903
31904
31905
31906
31907
31908
31909
31910
31911
31912
31913
31914
31915
Code
FORMAT CODES
Type
Definition
31916
31917
31918
31919
31920
31921
31922
31923
31924
31925
31926
31927
31928
31929
31930
31931
31932
31933
31934
31935
31936
31937
31938
31939
31960
31962
31963
31965
31967
31968
31970
Voltage Difference
31972
Angle Difference
31973
Frequency Difference
32020
Pwr1 Real
32022
Pwr1 Reactive
32024
Pwr1 Apparent
32026
Pwr1 Ph A Real
32028
Pwr1 Ph B Real
32030
Pwr1 Ph C Real
32032
Pwr1 Ph A Reactive
32034
Pwr1 Ph B Reactive
32036
Pwr1 Ph C Reactive
32038
Pwr1 Ph A Apparent
32040
Pwr1 Ph B Apparent
32042
Pwr1 Ph C Apparent
32044
Pwr1 PF
32045
Pwr1 Ph A PF
11-357
FORMAT CODES
Code
11-358
Type
Definition
32046
Pwr1 Ph B PF
32047
Pwr1 Ph C PF
32114
32118
32122
32124
32170
Power Factor 1
32171
Power Factor 2
32184
Cur1 Ph A Demand
32186
Cur1 Ph B Demand
32188
Cur1 Ph C Demand
32190
32192
32194
32222
Cur2 Ph A Demand
32224
Cur2 Ph B Demand
32226
Cur2 Ph C Demand
32228
32230
32232
32260
Cur3 Ph A Demand
32262
Cur3 Ph B Demand
32264
Cur3 Ph C Demand
32266
32268
32270
32314
32316
32322
32324
32330
32332
33100
33102
33104
33106
33108
33110
33112
33114
33116
33118
33120
33122
33430
33431
33432
Code
FORMAT CODES
Type
Definition
33450
Directional Power 1
33452
Directional Power 2
33460
33540
J1-CT Frequency
33542
33543
J2-3VT Frequency
33545
33546
J2-Vx Frequency
33548
33552
K1-CT Frequency
33554
33555
K2-3VT Frequency
33557
33558
K2-Vx Frequency
33560
33561
K2-CT Frequency
33563
33591
33592
33593
33599
33610
Motor Load
33611
33612
33613
33614
33616
33618
33620
33622
33624
33880
Ia Diff
33882
Ib Diff
33884
Ic Diff
33886
Ia Restr
33888
Ib Restr
33890
Ic Restr
33892
33893
33894
33895
33896
33897
33898
Ia Diff
33900
Ib Diff
33902
Ic Diff
33904
Ia Restr
11-359
FORMAT CODES
Code
11-360
Type
Definition
33906
Ib Restr
33908
Ic Restr
33932
33933
33934
33935
33936
33937
33938
Ia Ovrl Diff
33940
Ib Ovrl Diff
33942
Ic Ovrl Diff
33944
Ia Ovrl Restr
33946
Ib Ovrl Restr
33948
Ic Ovrl Restr
33960
33961
33962
33963
33980
RTD 1
33981
RTD 2
33982
RTD 3
33983
RTD 4
33984
RTD 5
33985
RTD 6
33986
RTD 7
33987
RTD 8
33988
RTD 9
33989
RTD 10
33990
RTD 11
33991
RTD 12
33992
RTD 13
34010
RTD 1 Max
34013
RTD 2 Max
34016
RTD 3 Max
34019
RTD 4 Max
34022
RTD 5 Max
34025
RTD 6 Max
34028
RTD 7 Max
34031
RTD 8 Max
34034
RTD 9 Max
34037
RTD 10 Max
34040
RTD 11 Max
34043
RTD 12 Max
34046
RTD 13 Max
34270
Analog Ip 1
34272
Analog Ip 2
34274
Analog Ip 3
Code
FORMAT CODES
Type
Definition
34276
Analog Ip 4
34420
W1 Load (% of rated)
Y
Y
34421
W1 Average Ph Current
34423
34432
W2 Load (% of rated)
34433
W2 Average Ph Current
34435
34444
W3 Load (% of rated)
34445
W3 Average Ph Current
34447
34460
34461
Aging Factor
34462
34464
34466
34467
Ambient Temperature
34480
Tap Position
34510
34511
34541
Running Hours
34544
34545
34580
FE1 Op Signal
34581
FE2 Op Signal
34582
FE3 Op Signal
34583
FE4 Op Signal
34584
FE5 Op Signal
34585
FE6 Op Signal
34586
FE7 Op Signal
34587
FE8 Op Signal
34610
Load Current
34611
Unbalance Current
34670
34671
34672
34857
Hydran (H2)
34862
34990
34992
Y
Y
34994
34996
34998
34999
35000
35001
35002
35003
11-361
FORMAT CODES
Code
11-362
Type
Definition
35004
35005
35050
Fast Frequency
35051
35100
PosImp1 Z1 Resistance
35102
PosImp1 Z1 Reactance
35104
PosImp1 Z1 Magnitude
35106
PosImp1 Z1 Angle
35110
PosImp2 Z1 Resistance
35112
PosImp2 Z1 Reactance
35114
PosImp2 Z1 Magnitude
35116
PosImp2 Z1 Angle
35120
Operating Quantity
35121
Learned Unbal Z
35140
HD J1 Ph A 2nd Harm
35141
HD J1 Ph B 2nd Harm
35142
HD J1 Ph C 2nd Harm
35143
HD J1 Ph A 3rd Harm
Y
Y
35144
HD J1 Ph B 3rd Harm
35145
HD J1 Ph C 3rd Harm
35146
HD J1 Ph A 4th Harm
35147
HD J1 Ph B 4th Harm
35148
HD J1 Ph C 4th Harm
35149
HD J1 Ph A 5th Harm
35150
HD J1 Ph B 5th Harm
35151
HD J1 Ph C 5th Harm
35152
HD K1 Ph A 2nd Harm
35153
HD K1 Ph B 2nd Harm
35154
HD K1 Ph C 2nd Harm
35155
HD K1 Ph A 3rd Harm
35156
HD K1 Ph B 3rd Harm
35157
HD K1 Ph C 3rd Harm
35158
HD K1 Ph A 4th Harm
35159
HD K1 Ph B 4th Harm
35160
HD K1 Ph C 4th Harm
35161
HD K1 Ph A 5th Harm
35162
HD K1 Ph B 5th Harm
35163
HD K1 Ph C 5th Harm
35164
HD K2 Ph A 2nd Harm
35165
HD K2 Ph B 2nd Harm
35166
HD K2 Ph C 2nd Harm
35167
HD K2 Ph A 3rd Harm
35168
HD K2 Ph B 3rd Harm
35169
HD K2 Ph C 3rd Harm
35170
HD K2 Ph A 4th Harm
35171
HD K2 Ph B 4th Harm
35172
HD K2 Ph C 4th Harm
Code
FC274
FC275
FC276
FC277
FC278
FORMAT CODES
Type
Definition
35173
HD K2 Ph A 5th Harm
35174
HD K2 Ph B 5th Harm
35175
HD K2 Ph C 5th Harm
35507
BSG3 - Temp C 1
35509
BSG3 - Temp C 2
35511
BSG3 - Temp C 3
35513
BSG3 - Temp C 4
35515
BSG3 - Temp C 5
35517
BSG3 - Temp C 6
35519
BSG3 - Temp C 7
35521
BSG3 - Temp C 8
35523
BSG3 - Temp C 9
35525
BSG3 - Temp F 1
35527
BSG3 - Temp F 2
35529
BSG3 - Temp F 3
35531
BSG3 - Temp F 4
35533
BSG3 - Temp F 5
35535
BSG3 - Temp F 6
35537
BSG3 - Temp F 7
35539
BSG3 - Temp F 8
35541
BSG3 - Temp F 9
35543
BSG3 - Power 1
35545
BSG3 - Power 2
35547
BSG3 - Power 3
35549
BSG3 - Power 4
35551
BSG3 - Power 5
35553
BSG3 - Power 6
35555
BSG3 - Power 7
35557
BSG3 - Power 8
35559
BSG3 - Power 9
unsigned 16 bits
0 to 1 mA
0 to 5 mA
0 to 10 mA
0 to 20 mA
4 to 20 mA
unsigned 16 bits
Over / Under
Over
Under
unsigned 16 bits
Wattmetric Current
Calculated IN
Measured IG
unsigned 16 bits
Detection
Monitoring
unsigned 16 bits
Self-Reset
11-363
FORMAT CODES
Code
FC279
FC280
FC283
FC284
FC286
FC287
FC288
FC289
11-364
Type
Definition
Latched
Pulsed
unsigned 16 bits
UV Restoration Initiation
Off
Ph UV 1 OP
Ph UV 2 OP
Aux UV 1 OP
Aux UV 2 OP
unsigned 16 bits
Bypass
unsigned 16 bits
Disabled
LB & DL
DB & LL
DB & DL
DB OR DL
DB XOR DL
unsigned 16 bits
Disabled
Incomer 1
Incomer 2
Bus Tie
unsigned 16 bits
Power 1
Power 2
unsigned 16 bits
UF Restoration Initiation
Off
UnderFreq 1 OP
UnderFreq 2 OP
UnderFreq 3 OP
UnderFreq 4 OP
UnderFreq 5 OP
UnderFreq 6 OP
10
11
Y
Y
12
unsigned 16 bits
No Security
Passwords Enabled
Full Security
unsigned 16 bits
Breaker Status
Not Set
Fail
Code
FC290
FC300
FORMAT CODES
Type
Definition
OK
unsigned 16 bits
Off
BKR1
BKR2
BKR3
11
CONT
15
AF 1
16
AF 2
17
AF 3
18
Inputs
19
Relays
20
V Inputs
21
V Outpts
30
Info
34
Dev Stat
35
Clock
36
PTP
37
Fault Loc
39
Arcing I
42
Values
43
SLD
44
Phasor J
45
Seq J
46
Phasor K
47
Seq K
68
CT1-J1
69
CT2-K1
70
CT3-K2
71
VT1-J2
72
VT2-K2
73
VT1x-J2
74
VT2x-K2
79
Harm1-J1
80
Harm2-J2
81
Harm3-K1
82
Harm4-K2
86
Power 1
87
Power 2
88
Energy 1
89
Energy 2
91
CurDmnd 1
92
CurDmnd 2
93
CurDmnd 3
94
Pwr Dmd1
95
Pwr Dmd2
unsigned 32 bits
LEDs 1-16
11-365
FORMAT CODES
Code
11-366
Type
Definition
0x00000000
Off
0x00000001
LED 1 Red
0x00000002
LED 1 Green
0x00000003
LED 1 Orange
0x00000004
LED 2 Red
0x00000008
LED 2 Green
0x0000000C
LED 2 Orange
0x00000010
LED 3 Red
0x00000020
LED 3 Green
0x00000030
LED 3 Orange
0x00000040
LED 4 Red
0x00000080
LED 4 Green
0x000000C0
LED 4 Orange
0x00000100
LED 5 Red
0x00000200
LED 5 Green
0x00000300
LED 5 Orange
0x00000400
LED 6 Red
0x00000800
LED 6 Green
0x00000C00
LED 6 Orange
0x00001000
LED 7 Red
0x00002000
LED 7 Green
0x00003000
LED 7 Orange
0x00004000
LED 8 Red
0x00008000
LED 8 Green
0x0000C000
LED 8 Orange
0x00010000
LED 9 Red
0x00020000
LED 9 Green
0x00030000
LED 9 Orange
0x00040000
LED 10 Red
0x00080000
LED 10 Green
0x000C0000
LED 10 Orange
0x00100000
LED 11 Red
0x00200000
LED 11 Green
0x00300000
LED 11 Orange
0x00400000
LED 12 Red
0x00800000
LED 12 Green
0x00C00000
LED 12 Orange
0x01000000
LED 13 Red
0x02000000
LED 13 Green
0x03000000
LED 13 Orange
0x04000000
LED 14 Red
0x08000000
LED 14 Green
0x0C000000
LED 14 Orange
0x10000000
LED 15 Red
0x20000000
LED 15 Green
0x30000000
LED 15 Orange
0x40000000
LED 16 Red
Code
FC301
FC322
FC323
FC323A
FORMAT CODES
Type
Definition
0x80000000
LED 16 Green
0xC0000000
LED 16 Orange
unsigned 32 bits
LEDs 17
0x00000000
Off
0x00000001
LED 17 Red
0x00000002
LED 17 Green
0x00000003
LED 17 Orange
unsigned 16 bits
Active Pushbutton
Off
Pushbutton 1 ON
Pushbutton 2 ON
Pushbutton 3 ON
unsigned 32 bits
0x00000001
GOOSE Status 1
0x00000002
GOOSE Status 2
0x00000004
GOOSE Status 3
0x00000008
GOOSE Status 4
0x00000010
GOOSE Status 5
0x00000020
GOOSE Status 6
0x00000040
GOOSE Status 7
0x00000080
GOOSE Status 8
0x00000100
GOOSE Status 9
0x00000200
GOOSE Status 10
0x00000400
GOOSE Status 11
0x00000800
GOOSE Status 12
0x00001000
GOOSE Status 13
0x00002000
GOOSE Status 14
0x00004000
GOOSE Status 15
0x00008000
GOOSE Status 16
0x00010000
GOOSE Status 17
0x00020000
GOOSE Status 18
0x00040000
GOOSE Status 19
0x00080000
GOOSE Status 20
0x00100000
GOOSE Status 21
0x00200000
GOOSE Status 22
0x00400000
GOOSE Status 23
0x00800000
GOOSE Status 24
0x01000000
GOOSE Status 25
0x02000000
GOOSE Status 26
0x04000000
GOOSE Status 27
0x08000000
GOOSE Status 28
0x10000000
GOOSE Status 29
0x20000000
GOOSE Status 30
0x40000000
GOOSE Status 31
0x80000000
GOOSE Status 32
unsigned 32 bits
0x00000001
GOOSE Status 33
11-367
FORMAT CODES
Code
FC324
FC340
FC341
FC342
11-368
Type
Definition
0x00000002
GOOSE Status 34
0x00000004
GOOSE Status 35
0x00000008
GOOSE Status 36
0x00000010
GOOSE Status 37
0x00000020
GOOSE Status 38
0x00000040
GOOSE Status 39
0x00000080
GOOSE Status 40
0x00000100
GOOSE Status 41
0x00000200
GOOSE Status 42
0x00000400
GOOSE Status 43
0x00000800
GOOSE Status 44
0x00001000
GOOSE Status 45
0x00002000
GOOSE Status 46
0x00004000
GOOSE Status 47
0x00008000
GOOSE Status 48
0x00010000
GOOSE Status 49
0x00020000
GOOSE Status 50
0x00040000
GOOSE Status 51
0x00080000
GOOSE Status 52
0x00100000
GOOSE Status 53
0x00200000
GOOSE Status 54
0x00400000
GOOSE Status 55
0x00800000
GOOSE Status 56
0x01000000
GOOSE Status 57
0x02000000
GOOSE Status 58
0x04000000
GOOSE Status 59
0x08000000
GOOSE Status 60
0x10000000
GOOSE Status 61
0x20000000
GOOSE Status 62
0x40000000
GOOSE Status 63
0x80000000
GOOSE Status 64
unsigned 16 bits
Read
Write
unsigned 16 bits
Disabled
Local
Remote
Local&Remote
unsigned 16 bits
EAP-TTLS
unsigned 16 bits
None
IRIG B
SNTP
FORMAT CODES
Code
Type
Definition
FC343
unsigned 16 bits
PTP State
Disabled
No Signal
Calibrating
Synchronized
unsigned 16 bits
0x00000001
Parameter 1
0x00000002
Parameter 2
0x00000004
Parameter 3
0x00000008
Parameter 4
0x00000010
Parameter 5
0x00000020
Parameter 6
0x00000040
Parameter 7
0x00000080
Parameter 8
FC344A
FC344B
FC344C
0x00000100
Parameter 9
0x00000200
Parameter 10
0x00000400
Parameter 11
0x00000800
Parameter 12
0x00001000
Parameter 13
0x00002000
Parameter 14
0x00004000
Parameter 15
0x00008000
Parameter 16
unsigned 16 bits
0x00000001
Parameter 17
0x00000002
Parameter 18
0x00000004
Parameter 19
0x00000008
Parameter 20
0x00000010
Parameter 21
0x00000020
Parameter 22
0x00000040
Parameter 23
0x00000080
Parameter 24
0x00000100
Parameter 25
0x00000200
Parameter 26
0x00000400
Parameter 27
0x00000800
Parameter 28
0x00001000
Parameter 29
0x00002000
Parameter 30
0x00004000
Parameter 31
0x00008000
Parameter 32
unsigned 16 bits
0x00000001
Parameter 33
0x00000002
Parameter 34
0x00000004
Parameter 35
0x00000008
Parameter 36
0x00000010
Parameter 37
0x00000020
Parameter 38
11-369
FORMAT CODES
Code
FC344D
FC344E
FC344F
11-370
Type
Definition
0x00000040
Parameter 39
0x00000080
Parameter 40
0x00000100
Parameter 41
0x00000200
Parameter 42
0x00000400
Parameter 43
0x00000800
Parameter 44
0x00001000
Parameter 45
0x00002000
Parameter 46
0x00004000
Parameter 47
0x00008000
Parameter 48
unsigned 16 bits
0x00000001
Parameter 49
0x00000002
Parameter 50
0x00000004
Parameter 51
0x00000008
Parameter 52
0x00000010
Parameter 53
0x00000020
Parameter 54
0x00000040
Parameter 55
0x00000080
Parameter 56
0x00000100
Parameter 57
0x00000200
Parameter 58
0x00000400
Parameter 59
0x00000800
Parameter 60
0x00001000
Parameter 61
0x00002000
Parameter 62
0x00004000
Parameter 63
0x00008000
Parameter 64
unsigned 16 bits
0x00000001
Parameter 65
0x00000002
Parameter 66
0x00000004
Parameter 67
0x00000008
Parameter 68
0x00000010
Parameter 69
0x00000020
Parameter 70
0x00000040
Parameter 71
0x00000080
Parameter 72
0x00000100
Parameter 73
0x00000200
Parameter 74
0x00000400
Parameter 75
0x00000800
Parameter 76
0x00001000
Parameter 77
0x00002000
Parameter 78
0x00004000
Parameter 79
0x00008000
Parameter 80
unsigned 16 bits
0x00000001
Parameter 81
0x00000002
Parameter 82
Code
FC344G
FC344H
FORMAT CODES
Type
Definition
0x00000004
Parameter 83
0x00000008
Parameter 84
0x00000010
Parameter 85
0x00000020
Parameter 86
0x00000040
Parameter 87
0x00000080
Parameter 88
0x00000100
Parameter 89
0x00000200
Parameter 90
0x00000400
Parameter 91
0x00000800
Parameter 92
0x00001000
Parameter 93
0x00002000
Parameter 94
0x00004000
Parameter 95
0x00008000
Parameter 96
unsigned 16 bits
0x00000001
Parameter 97
0x00000002
Parameter 98
0x00000004
Parameter 99
0x00000008
Parameter 100
0x00000010
Parameter 101
0x00000020
Parameter 102
0x00000040
Parameter 103
0x00000080
Parameter 104
0x00000100
Parameter 105
0x00000200
Parameter 106
0x00000400
Parameter 107
0x00000800
Parameter 108
0x00001000
Parameter 109
0x00002000
Parameter 110
0x00004000
Parameter 111
0x00008000
Parameter 112
unsigned 16 bits
0x00000001
Parameter 113
0x00000002
Parameter 114
0x00000004
Parameter 115
0x00000008
Parameter 116
0x00000010
Parameter 117
0x00000020
Parameter 118
0x00000040
Parameter 119
0x00000080
Parameter 120
0x00000100
Parameter 121
0x00000200
Parameter 122
0x00000400
Parameter 123
0x00000800
Parameter 124
0x00001000
Parameter 125
0x00002000
Parameter 126
0x00004000
Parameter 127
11-371
FORMAT CODES
Code
FC344I
FC344J
FC344K
11-372
Type
Definition
0x00008000
Parameter 128
unsigned 16 bits
0x00000001
Parameter 129
0x00000002
Parameter 130
0x00000004
Parameter 131
0x00000008
Parameter 132
0x00000010
Parameter 133
0x00000020
Parameter 134
0x00000040
Parameter 135
0x00000080
Parameter 136
0x00000100
Parameter 137
0x00000200
Parameter 138
0x00000400
Parameter 139
0x00000800
Parameter 140
0x00001000
Parameter 141
0x00002000
Parameter 142
0x00004000
Parameter 143
0x00008000
Parameter 144
unsigned 16 bits
0x00000001
Parameter 145
0x00000002
Parameter 146
0x00000004
Parameter 147
0x00000008
Parameter 148
0x00000010
Parameter 149
0x00000020
Parameter 150
0x00000040
Parameter 151
0x00000080
Parameter 152
0x00000100
Parameter 153
0x00000200
Parameter 154
0x00000400
Parameter 155
0x00000800
Parameter 156
0x00001000
Parameter 157
0x00002000
Parameter 158
0x00004000
Parameter 159
0x00008000
Parameter 160
unsigned 16 bits
0x00000001
Parameter 161
0x00000002
Parameter 162
0x00000004
Parameter 163
0x00000008
Parameter 164
0x00000010
Parameter 165
0x00000020
Parameter 166
0x00000040
Parameter 167
0x00000080
Parameter 168
0x00000100
Parameter 169
0x00000200
Parameter 170
0x00000400
Parameter 171
Code
FC344L
FC344M
FC344N
FORMAT CODES
Type
Definition
0x00000800
Parameter 172
0x00001000
Parameter 173
0x00002000
Parameter 174
0x00004000
Parameter 175
0x00008000
Parameter 176
unsigned 16 bits
0x00000001
Parameter 177
0x00000002
Parameter 178
0x00000004
Parameter 179
0x00000008
Parameter 180
0x00000010
Parameter 181
0x00000020
Parameter 182
0x00000040
Parameter 183
0x00000080
Parameter 184
0x00000100
Parameter 185
0x00000200
Parameter 186
0x00000400
Parameter 187
0x00000800
Parameter 188
0x00001000
Parameter 189
0x00002000
Parameter 190
0x00004000
Parameter 191
0x00008000
Parameter 192
unsigned 16 bits
0x00000001
Parameter 193
0x00000002
Parameter 194
0x00000004
Parameter 195
0x00000008
Parameter 196
0x00000010
Parameter 197
0x00000020
Parameter 198
0x00000040
Parameter 199
0x00000080
Parameter 200
0x00000100
Parameter 201
0x00000200
Parameter 202
0x00000400
Parameter 203
0x00000800
Parameter 204
0x00001000
Parameter 205
0x00002000
Parameter 206
0x00004000
Parameter 207
0x00008000
Parameter 208
unsigned 16 bits
0x00000001
Parameter 209
0x00000002
Parameter 210
0x00000004
Parameter 211
0x00000008
Parameter 212
0x00000010
Parameter 213
0x00000020
Parameter 214
0x00000040
Parameter 215
11-373
FORMAT CODES
Code
FC344O
FC344P
FC350
11-374
Type
Definition
0x00000080
Parameter 216
0x00000100
Parameter 217
0x00000200
Parameter 218
0x00000400
Parameter 219
0x00000800
Parameter 220
0x00001000
Parameter 221
0x00002000
Parameter 222
0x00004000
Parameter 223
0x00008000
Parameter 224
unsigned 16 bits
0x00000001
Parameter 225
0x00000002
Parameter 226
0x00000004
Parameter 227
0x00000008
Parameter 228
0x00000010
Parameter 229
0x00000020
Parameter 230
0x00000040
Parameter 231
0x00000080
Parameter 232
0x00000100
Parameter 233
0x00000200
Parameter 234
0x00000400
Parameter 235
0x00000800
Parameter 236
0x00001000
Parameter 237
0x00002000
Parameter 238
0x00004000
Parameter 239
0x00008000
Parameter 240
unsigned 16 bits
0x00000001
Parameter 241
0x00000002
Parameter 242
0x00000004
Parameter 243
0x00000008
Parameter 244
0x00000010
Parameter 245
0x00000020
Parameter 246
0x00000040
Parameter 247
0x00000080
Parameter 248
0x00000100
Parameter 249
0x00000200
Parameter 250
0x00000400
Parameter 251
0x00000800
Parameter 252
0x00001000
Parameter 253
0x00002000
Parameter 254
0x00004000
Parameter 255
0x00008000
Parameter 256
unsigned 16 bits
Motor Status
Tripped
Stopped
Starting
Code
FC350A
FC350B
FC350C
FC351
FC352
FC353
FC354
FC356
FC357
FC358
FC359
FC367
FC368
FORMAT CODES
Type
Definition
Running
Overload
unsigned 16 bits
Transformer Status
De-Energized
Energized
Not Configured
unsigned 16 bits
Generator Status
Offline
Online
Tripped
unsigned 16 bits
Offline
Online
unsigned 16 bits
Motor Speed
Low Speed
High Speed
unsigned 16 bits
Definite Time
Adaptive
unsigned 16 bits
Cutoff
Shift
unsigned 16 bits
None
Alarm
Block
unsigned 16 bits
Differential Type
Internal Sum
Core Balance
unsigned 16 bits
Disabled
unsigned 16 bits
Per Phase
Average
2-out-of-3
1-out-of-3
unsigned 16 bits
Disabled
5th Harm
unsigned 16 bits
55C (oil)
65C (oil)
80C (dry)
115C (dry)
150C (dry)
unsigned 16 bits
11-375
FORMAT CODES
Code
FC369
FC370
FC371
11-376
Type
Definition
OA
FA
Non-Directed FOA//FOW
Directed FOA//FOW
Forced Cooled
unsigned 16 bits
Internal (software)
unsigned 16 bits
Monthly Average
dcmA 1
dcmA 2
dcmA 3
dcmA 4
13
RTD 1
14
RTD 2
15
RTD 3
16
RTD 4
17
RTD 5
18
RTD 6
19
RTD 7
20
RTD 8
21
RTD 9
22
RTD 10
23
RTD 11
24
RTD 12
25
RTD 13
unsigned 16 bits
Computed
dcmA 1
dcmA 2
dcmA 3
dcmA 4
13
RTD 1
14
RTD 2
15
RTD 3
16
RTD 4
17
RTD 5
18
RTD 6
19
RTD 7
20
RTD 8
21
RTD 9
22
RTD 10
23
RTD 11
24
RTD 12
Code
FC372
FC373
FC374
FC375
FC376
FC377
FC378
FC379
FC380
FORMAT CODES
Type
Definition
25
RTD 13
unsigned 16 bits
BCD
Ohms In 1
Y
Y
Analog In 1
unsigned 16 bits
Current Only
Current or Timer
unsigned 16 bits
Harmonic Detection
2nd
3rd
4th
5th
THD
unsigned 16 bits
Wye
Delta
Zig-Zag
unsigned 16 bits
Xfmr Grounding
Within Zone
unsigned 16 bits
30 Lag
60 Lag
90 Lag
120 Lag
150 Lag
180 Lag
210 Lag
240 Lag
270 Lag
10
300 Lag
11
330 Lag
unsigned 16 bits
Level
Delta
unsigned 16 bits
Signed
Absolute
unsigned 16 bits
None
Transfix
DGA 500
Minitrans
HM2
11-377
FORMAT CODES
Code
Type
Definition
FC381
unsigned 16 bits
Tachometer Direction
Underspeed
FC382
FC384
FC385
FC386
FC387
FC388
FC389
FC391
FC392
FC393
FC394
11-378
Overspeed
unsigned 16 bits
U/V or Offline
unsigned 16 bits
Blinder Exit
MHO Exit
unsigned 16 bits
Unknown
Open
Close
unsigned 16 bits
Disabled
Enabled
Excitation Current
Bearing Vibration
unsigned 16 bits
0x0001
Light 1 PKP
0x0002
Light 2 PKP
0x0004
Light 3 PKP
0x0008
Light 4 PKP
0x0100
0x0200
0x0400
0x0800
0x1000
Arc Flash OP
unsigned 16 bits
UF Only
UF and df/dt
unsigned 16 bits
Auto
Manual
unsigned 16 bits
Positive Impedance 1
Positive Impedance 2
unsigned 16 bits
None
BSG3
unsigned 16 bits
None
Internal
unsigned 32 bits
0x00000001
BSG3 - Status 1
0x00000002
BSG3 - Status 2
0x00000004
BSG3 - Status 3
Code
FC395
FORMAT CODES
Type
Definition
0x00000008
BSG3 - Status 4
0x00000010
BSG3 - Status 5
0x00000020
BSG3 - Status 6
0x00000040
BSG3 - Status 7
0x00000080
BSG3 - Status 8
0x00000100
BSG3 - Status 9
0x00000200
BSG3 - Warning 1
0x00000400
BSG3 - Warning 2
0x00000800
BSG3 - Warning 3
0x00001000
BSG3 - Warning 4
0x00002000
BSG3 - Warning 5
0x00004000
BSG3 - Warning 6
0x00008000
BSG3 - Warning 7
0x00010000
BSG3 - Warning 8
0x00020000
BSG3 - Warning 9
0x00040000
BSG3 - Alarm 1
0x00080000
BSG3 - Alarm 2
0x00100000
BSG3 - Alarm 3
0x00200000
BSG3 - Alarm 4
0x00400000
BSG3 - Alarm 5
0x00800000
BSG3 - Alarm 6
0x01000000
BSG3 - Alarm 7
0x02000000
BSG3 - Alarm 8
0x04000000
BSG3 - Alarm 9
0x08000000
FlexLogic Operand 28
0x10000000
FlexLogic Operand 29
0x20000000
FlexLogic Operand 30
0x40000000
FlexLogic Operand 31
0x80000000
FlexLogic Operand 32
unsigned 32 bits
0x00000001
FlexLogic Operand 33
0x00000002
FlexLogic Operand 34
0x00000004
FlexLogic Operand 35
0x00000008
FlexLogic Operand 36
0x00000010
FlexLogic Operand 37
0x00000020
FlexLogic Operand 38
0x00000040
FlexLogic Operand 39
0x00000080
FlexLogic Operand 40
0x00000100
FlexLogic Operand 41
0x00000200
FlexLogic Operand 42
0x00000400
FlexLogic Operand 43
0x00000800
FlexLogic Operand 44
0x00001000
FlexLogic Operand 45
0x00002000
FlexLogic Operand 46
0x00004000
FlexLogic Operand 47
0x00008000
FlexLogic Operand 48
0x00010000
FlexLogic Operand 49
11-379
FORMAT CODES
Code
FE001
Type
Definition
0x00020000
FlexLogic Operand 50
0x00040000
FlexLogic Operand 51
0x00080000
FlexLogic Operand 52
0x00100000
FlexLogic Operand 53
0x00200000
FlexLogic Operand 54
0x00400000
FlexLogic Operand 55
0x00800000
FlexLogic Operand 56
0x01000000
FlexLogic Operand 57
0x02000000
FlexLogic Operand 58
0x04000000
FlexLogic Operand 59
0x08000000
FlexLogic Operand 60
0x10000000
FlexLogic Operand 61
0x20000000
FlexLogic Operand 62
0x40000000
FlexLogic Operand 63
0x80000000
FlexLogic Operand 64
unsigned 16 bits
0x0002
Any Trip
FE002
unsigned 16 bits
0x0002
Any Alarm
FE005
unsigned 16 bits
0x0002
Any Block
FE006
unsigned 16 bits
0x0002
Any PKP
unsigned 16 bits
FE007
FE008
FE009
FE010
FE011
FE012
FE013
11-380
0x0002
Any OP
unsigned 16 bits
0x0002
Reset OP
0x0008
Reset OP (PB)
0x0010
Reset OP (Operand)
0x0020
Reset OP (Comms)
unsigned 16 bits
0x0002
Setpoint Access OP
0x0040
Setting Change
unsigned 16 bits
0x0001
0x0004
Authentication Lockout
0x0010
Authentication Fail
0x0020
0x0040
0x0080
0x0100
unsigned 16 bits
0x0002
Login
0x0004
Logout
unsigned 16 bits
0x0002
Active Target
unsigned 16 bits
Code
FORMAT CODES
Type
Definition
0x0002
In-Service
FE015
unsigned 16 bits
0x0002
FE016
unsigned 16 bits
FE017
FE018
FE019
FE020
FE021
FE022
FE023
FE024
FE025
0x0002
0x0040
IRIG-B Failure
0x0080
SNTP Failure
0x0100
PTP Failure
unsigned 16 bits
Element Status: PB 1
0x0002
PB 1 ON
0x0004
PB 1 OFF
unsigned 16 bits
Element Status: PB 2
0x0002
PB 2 ON
0x0004
PB 2 OFF
unsigned 16 bits
Element Status: PB 3
0x0002
PB 3 ON
0x0004
PB 3 OFF
unsigned 16 bits
0x0002
Von
0x0004
Voff
unsigned 16 bits
0x0002
Von
0x0004
Voff
unsigned 16 bits
0x0002
Von
0x0004
Voff
unsigned 16 bits
0x0002
Von
0x0004
Voff
unsigned 16 bits
0x0002
Von
Y
Y
0x0004
Voff
unsigned 16 bits
0x0002
Von
Y
Y
0x0004
Voff
FE026
unsigned 16 bits
0x0002
Critical Fail OP
FE028
unsigned 16 bits
0x0001
Motor Starting
0x0002
Motor Running
0x0004
Motor Stopped
0x0008
Motor Speed 2
0x0010
Speed2 TR 2-1 OP
0x0020
0x0040
Motor Overload
0x0080
Motor Tripped
0x0100
Emergency Restart
11-381
FORMAT CODES
Code
Type
Definition
FE029
unsigned 16 bits
0x0002
BKR1 Closed
FE030
FE031
FE032
FE033
FE034
FE035
FE036
FE037
FE038
FE039
FE040
FE041
FE042
FE043
FE044
FE045
FE046
11-382
unsigned 16 bits
0x0002
BKR1 Opened
unsigned 16 bits
0x0002
0x0004
unsigned 16 bits
0x0002
BKR1 Disconnected
0x0004
BKR1 Connected
unsigned 16 bits
0x0002
BKR1 52a CI ON
0x0004
unsigned 16 bits
0x0002
BKR1 52b CI ON
0x0004
unsigned 16 bits
0x0002
BKR2 Closed
unsigned 16 bits
0x0002
BKR2 Opened
unsigned 16 bits
0x0002
0x0004
unsigned 16 bits
0x0002
BKR2 Disconnected
0x0004
BKR2 Connected
unsigned 16 bits
0x0002
BKR2 52a CI ON
0x0004
unsigned 16 bits
0x0002
BKR2 52b CI ON
0x0004
unsigned 16 bits
0x0002
BKR3 Closed
unsigned 16 bits
0x0002
BKR3 Opened
Y
Y
unsigned 16 bits
0x0002
0x0004
unsigned 16 bits
0x0002
BKR3 Disconnected
0x0004
BKR3 Connected
unsigned 16 bits
0x0002
BKR3 52a CI ON
Y
Y
0x0004
unsigned 16 bits
0x0002
BKR3 52b CI ON
Code
FORMAT CODES
Type
Definition
0x0004
FE047
unsigned 16 bits
0x0002
Contactor Closed
FE048
unsigned 16 bits
0x0002
Contactor Open
FE049
unsigned 16 bits
0x0002
Y
Y
FE050
FE051
FE052
FE065
FE066
FE067
FE068
FE069
0x0004
unsigned 16 bits
0x0002
Contactor Disconnect
Y
Y
0x0004
Contactor Connected
unsigned 16 bits
0x0008
Local Stop
0x0010
Remote Stop
unsigned 16 bits
0x0008
Local Start
0x0010
Remote Start
unsigned 16 bits
0x0040
VFD Bypassed
0x0080
unsigned 16 bits
0x0001
0x0002
Percent Diff OP
0x0008
0x0010
0x0020
0x0040
Percent Diff OP A
0x0080
Percent Diff OP B
0x0100
Percent Diff OP C
unsigned 16 bits
0x0001
0x0002
0x0008
0x0010
0x0020
0x0040
0x0080
0x0100
unsigned 16 bits
0x0002
0x0040
0x0080
0x0100
unsigned 16 bits
0x0002
0x0040
0x0080
11-383
FORMAT CODES
Code
FE070
FE071
Type
Definition
0x0100
unsigned 16 bits
0x0002
0x0040
0x0080
0x0100
unsigned 16 bits
0x0080
Y
Y
0x0100
0x0002
FE073
unsigned 16 bits
0x0002
FE076
FE077
FE078
FE079
FE080
11-384
0x0040
unsigned 16 bits
FE075
Y
Y
0x0002
FE072
FE074
unsigned 16 bits
0x0002
0x0008
0x0010
0x0020
0x0040
0x0080
0x0100
unsigned 16 bits
0x0002
0x0008
0x0010
0x0020
0x0040
0x0080
0x0100
unsigned 16 bits
0x0002
Instant Diff OP
0x0040
Instant Diff OP A
0x0080
Instant Diff OP B
0x0100
Instant Diff OP C
unsigned 16 bits
0x0002
Instant Diff OP
0x0040
Instant Diff OP A
0x0080
Instant Diff OP B
0x0100
Instant Diff OP C
unsigned 16 bits
0x0001
Thermal PKP
0x0002
Thermal OP
unsigned 16 bits
0x0002
Thermal Alarm OP
unsigned 16 bits
Code
FE081
FE082
FE083
FE084
FE085
FE086
FE088
FE089
FORMAT CODES
Type
Definition
0x0001
0x0002
unsigned 16 bits
0x0001
0x0002
Cur Unbal OP
0x0040
Single Phasing OP
unsigned 16 bits
0x0001
0x0002
Mech Jam OP
unsigned 16 bits
0x0001
0x0002
Undercur Alarm OP
unsigned 16 bits
0x0001
Undercur PKP
0x0002
Undercur OP
unsigned 16 bits
0x0001
Overload PKP
0x0002
Overload OP
unsigned 16 bits
0x0001
Y
Y
0x0002
Short Circuit OP
unsigned 16 bits
0x0001
Y
Y
0x0002
GndFault Alarm OP
unsigned 16 bits
0x0001
GndFault PKP
Y
Y
0x0002
GndFault OP
FE090
unsigned 16 bits
0x0002
FE091
unsigned 16 bits
0x0002
unsigned 16 bits
0x0001
0x0002
Underpwr Alarm OP
unsigned 16 bits
0x0001
Underpwr PKP
Y
Y
FE092
FE093
FE094
FE095
FE096
0x0002
Underpwr OP
unsigned 16 bits
0x0001
Overload PKP
Y
Y
0x0002
Overload OP
0x0008
W1 Overload PKP
0x0010
W2 Overload PKP
Y
Y
0x0020
W3 Overload PKP
unsigned 16 bits
0x0001
0x0002
unsigned 16 bits
11-385
FORMAT CODES
Code
FE097
FE098
FE099
FE100
FE101
11-386
Type
Definition
0x0001
0x0002
Spd2 U/C OP
unsigned 16 bits
0x0001
Ph TOC 1 PKP
0x0002
Ph TOC 1 OP
0x0008
Ph TOC 1 PKP A
0x0010
Ph TOC 1 PKP B
0x0020
Ph TOC 1 PKP C
0x0040
Ph TOC 1 OP A
0x0080
Ph TOC 1 OP B
0x0100
Ph TOC 1 OP C
unsigned 16 bits
0x0001
Ph TOC 2 PKP
0x0002
Ph TOC 2 OP
0x0008
Ph TOC 2 PKP A
0x0010
Ph TOC 2 PKP B
0x0020
Ph TOC 2 PKP C
0x0040
Ph TOC 2 OP A
0x0080
Ph TOC 2 OP B
0x0100
Ph TOC 2 OP C
unsigned 16 bits
0x0001
Ph TOC 3 PKP
0x0002
Ph TOC 3 OP
0x0008
Ph TOC 3 PKP A
0x0010
Ph TOC 3 PKP B
0x0020
Ph TOC 3 PKP C
0x0040
Ph TOC 3 OP A
0x0080
Ph TOC 3 OP B
0x0100
Ph TOC 3 OP C
unsigned 16 bits
0x0001
Ph IOC 1 PKP
0x0002
Ph IOC 1 OP
0x0008
Ph IOC 1 PKP A
0x0010
Ph IOC 1 PKP B
0x0020
Ph IOC 1 PKP C
0x0040
Ph IOC 1 OP A
0x0080
Ph IOC 1 OP B
0x0100
Ph IOC 1 OP C
unsigned 16 bits
0x0001
Ph IOC 2 PKP
0x0002
Ph IOC 2 OP
0x0008
Ph IOC 2 PKP A
0x0010
Ph IOC 2 PKP B
0x0020
Ph IOC 2 PKP C
0x0040
Ph IOC 2 OP A
0x0080
Ph IOC 2 OP B
0x0100
Ph IOC 2 OP C
FORMAT CODES
Code
Type
Definition
FE102
unsigned 16 bits
0x0001
Ph IOC 3 PKP
FE103
FE104
FE105
FE106
FE107
0x0002
Ph IOC 3 OP
0x0008
Ph IOC 3 PKP A
0x0010
Ph IOC 3 PKP B
0x0020
Ph IOC 3 PKP C
0x0040
Ph IOC 3 OP A
0x0080
Ph IOC 3 OP B
0x0100
Ph IOC 3 OP C
unsigned 16 bits
0x0001
Ph IOC 4 PKP
0x0002
Ph IOC 4 OP
0x0008
Ph IOC 4 PKP A
0x0010
Ph IOC 4 PKP B
0x0020
Ph IOC 4 PKP C
0x0040
Ph IOC 4 OP A
0x0080
Ph IOC 4 OP B
0x0100
Ph IOC 4 OP C
unsigned 16 bits
0x0001
Ph IOC 5 PKP
0x0002
Ph IOC 5 OP
0x0008
Ph IOC 5 PKP A
0x0010
Ph IOC 5 PKP B
0x0020
Ph IOC 5 PKP C
0x0040
Ph IOC 5 OP A
0x0080
Ph IOC 5 OP B
Y
Y
0x0100
Ph IOC 5 OP C
unsigned 16 bits
0x0001
Ph IOC 6 PKP
0x0002
Ph IOC 6 OP
0x0008
Ph IOC 6 PKP A
0x0010
Ph IOC 6 PKP B
0x0020
Ph IOC 6 PKP C
0x0040
Ph IOC 6 OP A
0x0080
Ph IOC 6 OP B
0x0100
Ph IOC 6 OP C
unsigned 16 bits
0x0001
Ph IOC 7 PKP
0x0002
Ph IOC 7 OP
0x0008
Ph IOC 7 PKP A
0x0010
Ph IOC 7 PKP B
0x0020
Ph IOC 7 PKP C
0x0040
Ph IOC 7 OP A
0x0080
Ph IOC 7 OP B
Y
Y
0x0100
Ph IOC 7 OP C
unsigned 16 bits
0x0001
Ph IOC 8 PKP
11-387
FORMAT CODES
Code
FE108
FE109
FE110
FE111
FE112
FE113
FE114
FE115
FE116
FE117
FE118
FE119
FE120
11-388
Type
Definition
0x0002
Ph IOC 8 OP
0x0008
Ph IOC 8 PKP A
0x0010
Ph IOC 8 PKP B
0x0020
Ph IOC 8 PKP C
0x0040
Ph IOC 8 OP A
0x0080
Ph IOC 8 OP B
0x0100
Ph IOC 8 OP C
unsigned 16 bits
0x0002
Ph Dir OC REV
0x0040
Ph Dir OC REV A
0x0080
Ph Dir OC REV B
0x0100
Ph Dir OC REV C
unsigned 16 bits
0x0001
0x0002
Ntrl TOC 1 OP
unsigned 16 bits
0x0001
0x0002
Ntrl TOC 2 OP
unsigned 16 bits
0x0001
Y
Y
0x0002
Ntrl TOC 3 OP
unsigned 16 bits
0x0001
0x0002
Ntrl IOC 1 OP
unsigned 16 bits
0x0001
0x0002
Ntrl IOC 2 OP
unsigned 16 bits
0x0001
0x0002
Ntrl IOC 3 OP
unsigned 16 bits
0x0001
0x0002
Ntrl IOC 4 OP
unsigned 16 bits
0x0001
0x0002
Ntrl IOC 5 OP
unsigned 16 bits
0x0001
0x0002
Ntrl IOC 6 OP
unsigned 16 bits
0x0008
0x0040
unsigned 16 bits
0x0001
0x0002
GND TOC 1 OP
unsigned 16 bits
0x0001
Code
FE121
FE122
FE123
FE124
FE125
FE126
FE127
FE129
FE134
FE135
FE136
FE137
FE138
FE139
FE140
FORMAT CODES
Type
Definition
0x0002
GND TOC 2 OP
unsigned 16 bits
0x0001
0x0002
GND TOC 3 OP
unsigned 16 bits
0x0001
0x0002
GND IOC 1 OP
unsigned 16 bits
0x0001
0x0002
GND IOC 2 OP
unsigned 16 bits
0x0001
Y
Y
0x0002
GND IOC 3 OP
unsigned 16 bits
0x0001
Y
Y
0x0002
GND IOC 4 OP
unsigned 16 bits
0x0001
Y
Y
0x0002
GND IOC 5 OP
unsigned 16 bits
0x0001
0x0002
GND IOC 6 OP
unsigned 16 bits
0x0001
0x0002
SGND TOC 1 OP
unsigned 16 bits
0x0001
RGF 1 PKP
0x0002
RGF 1 OP
0x0008
RGF 1 Superv ON
unsigned 16 bits
0x0001
RGF 2 PKP
0x0002
RGF 2 OP
0x0008
RGF 2 Superv ON
unsigned 16 bits
0x0001
RGF 3 PKP
0x0002
RGF 3 OP
Y
Y
0x0008
RGF 3 Superv ON
unsigned 16 bits
0x0001
0x0002
NegSeq TOC 1 OP
unsigned 16 bits
0x0001
Y
Y
0x0002
NegSeq TOC 2 OP
unsigned 16 bits
0x0001
0x0002
NegSeq TOC 3 OP
unsigned 16 bits
11-389
FORMAT CODES
Code
FE141
FE142
FE143
FE144
FE145
FE146
FE147
FE148
FE149
FE150
11-390
Type
Definition
0x0001
0x0002
NegSeq IOC 1 OP
unsigned 16 bits
0x0001
0x0002
NegSeq IOC 2 OP
unsigned 16 bits
0x0001
0x0002
NegSeq IOC 3 OP
unsigned 16 bits
0x0008
0x0040
unsigned 16 bits
0x0001
0x0002
Broken Cond OP
unsigned 16 bits
0x0001
0x0002
Load Encro OP
unsigned 16 bits
0x0001
Thermal PKP
0x0002
Thermal OP
0x0008
Thermal PKP A
0x0010
Thermal PKP B
0x0020
Thermal PKP C
0x0040
Thermal OP A
0x0080
Thermal OP B
0x0100
Thermal OP C
unsigned 16 bits
0x0002
Thermal Alarm
0x0040
Thermal Alarm A
0x0080
Thermal Alarm B
0x0100
Thermal Alarm C
unsigned 16 bits
0x0001
0x0002
Phase Rev OP
0x0040
unsigned 16 bits
Element Status: Ph UV 1
0x0001
Ph UV 1 PKP
0x0002
Ph UV 1 OP
0x0008
Ph UV 1 PKP A
0x0010
Ph UV 1 PKP B
0x0020
Ph UV 1 PKP C
0x0040
Ph UV 1 OP A
0x0080
Ph UV 1 OP B
0x0100
Ph UV 1 OP C
unsigned 16 bits
Element Status: Ph UV 2
0x0001
Ph UV 2 PKP
0x0002
Ph UV 2 OP
Code
FE151
FE152
FE153
FE154
FE155
FE156
FE157
FE159
FE160
FE161
FORMAT CODES
Type
Definition
0x0008
Ph UV 2 PKP A
0x0010
Ph UV 2 PKP B
0x0020
Ph UV 2 PKP C
0x0040
Ph UV 2 OP A
0x0080
Ph UV 2 OP B
0x0100
Ph UV 2 OP C
unsigned 16 bits
0x0001
Aux UV 1 PKP
0x0002
Aux UV 1 OP
unsigned 16 bits
0x0001
Aux UV 2 PKP
0x0002
Aux UV 2 OP
unsigned 16 bits
Element Status: Ph OV 1
0x0001
Ph OV 1 PKP
0x0002
Ph OV 1 OP
0x0008
Ph OV 1 PKP A
0x0010
Ph OV 1 PKP B
0x0020
Ph OV 1 PKP C
0x0040
Ph OV 1 OP A
0x0080
Ph OV 1 OP B
0x0100
Ph OV 1 OP C
unsigned 16 bits
Element Status: Ph OV 2
0x0001
Ph OV 2 PKP
0x0002
Ph OV 2 OP
0x0008
Ph OV 2 PKP A
0x0010
Ph OV 2 PKP B
0x0020
Ph OV 2 PKP C
0x0040
Ph OV 2 OP A
0x0080
Ph OV 2 OP B
0x0100
Ph OV 2 OP C
unsigned 16 bits
0x0001
Aux OV 1 PKP
0x0002
Aux OV 1 OP
unsigned 16 bits
0x0001
Aux OV 2 PKP
0x0002
Aux OV 2 OP
Y
Y
0x0004
Aux OV 2 DPO
unsigned 16 bits
0x0001
Ntrl OV 1 PKP
0x0002
Ntrl OV 1 OP
unsigned 16 bits
0x0001
NegSeq OV 1 PKP
0x0002
NegSeq OV 1 OP
unsigned 16 bits
0x0001
NegSeq OV 2 PKP
0x0002
NegSeq OV 2 OP
unsigned 16 bits
11-391
FORMAT CODES
Code
FE162
FE163
FE164
FE165
FE167
FE168
FE169
FE170
FE171
FE172
FE173
FE174
FE175
11-392
Type
Definition
0x0001
V/Hz 1 PKP
0x0002
V/Hz 1 OP
unsigned 16 bits
0x0001
V/Hz 2 PKP
0x0002
V/Hz 2 OP
unsigned 16 bits
0x0001
DirPwr 1 PKP
0x0002
DirPwr 1 OP
0x0008
0x0010
0x0040
DirPwr 1 Stg1 OP
0x0080
DirPwr 1 Stg2 OP
unsigned 16 bits
0x0001
DirPwr 2 PKP
0x0002
DirPwr 2 OP
0x0008
0x0010
0x0040
DirPwr 2 Stg1 OP
0x0080
DirPwr 2 Stg2 OP
unsigned 16 bits
0x0001
0x0002
Watt GndFlt 1 OP
unsigned 16 bits
Element Status: UF 1
0x0001
Underfreq 1 PKP
0x0002
Underfreq 1 OP
unsigned 16 bits
Element Status: UF 2
0x0001
Underfreq 2 PKP
0x0002
Underfreq 2 OP
unsigned 16 bits
Element Status: UF 3
0x0001
Underfreq 3 PKP
0x0002
Underfreq 3 OP
unsigned 16 bits
Element Status: UF 4
0x0001
Underfreq 4 PKP
0x0002
Underfreq 4 OP
unsigned 16 bits
Element Status: UF 5
0x0001
Underfreq 5 PKP
Y
Y
0x0002
Underfreq 5 OP
unsigned 16 bits
Element Status: UF 6
0x0001
Underfreq 6 PKP
Y
Y
0x0002
Underfreq 6 OP
unsigned 16 bits
Element Status: OF 1
0x0001
Overfreq 1 PKP
0x0002
Overfreq 1 OP
unsigned 16 bits
Element Status: OF 2
0x0001
Overfreq 2 PKP
0x0002
Overfreq 2 OP
unsigned 16 bits
Element Status: OF 3
Code
FE176
FE177
FE178
FE179
FE180
FE181
FE182
FORMAT CODES
Type
Definition
0x0001
Overfreq 3 PKP
0x0002
Overfreq 3 OP
unsigned 16 bits
Element Status: OF 4
0x0001
Overfreq 4 PKP
Y
Y
0x0002
Overfreq 4 OP
unsigned 16 bits
0x0001
FreqRate1 PKP
0x0002
FreqRate1 OP
0x0008
FreqRate1 Up PKP
0x0010
0x0040
FreqRate1 Up OP
0x0080
FreqRate1 Dwn OP
unsigned 16 bits
0x0001
FreqRate2 PKP
0x0002
FreqRate2 OP
0x0008
FreqRate2 Up PKP
0x0010
0x0040
FreqRate2 Up OP
0x0080
FreqRate2 Dwn OP
unsigned 16 bits
0x0001
FreqRate3 PKP
0x0002
FreqRate3 OP
0x0008
FreqRate3 Up PKP
0x0010
0x0040
FreqRate3 Up OP
0x0080
FreqRate3 Dwn OP
unsigned 16 bits
0x0001
FreqRate4 PKP
0x0002
FreqRate4 OP
0x0008
FreqRate4 Up PKP
0x0010
0x0040
FreqRate4 Up OP
0x0080
FreqRate4 Dwn OP
unsigned 16 bits
0x0001
FreqRate5 PKP
0x0002
FreqRate5 OP
0x0008
FreqRate5 Up PKP
0x0010
0x0040
FreqRate5 Up OP
Y
Y
0x0080
FreqRate5 Dwn OP
unsigned 16 bits
0x0001
FreqRate6 PKP
0x0002
FreqRate6 OP
0x0008
FreqRate6 Up PKP
0x0010
0x0040
FreqRate6 Up OP
0x0080
FreqRate6 Dwn OP
11-393
FORMAT CODES
Code
Type
Definition
FE183
unsigned 16 bits
0x0002
Xfmr Energized
0x0004
Xfmr De-Energized
0x0008
Not Configured
unsigned 16 bits
FE184
0x0008
0x0010
0x0020
0x0040
TC at Min Tap ON
0x0080
TC at Ntrl Tap ON
Y
Y
0x0100
TC at Max Tap ON
FE185
unsigned 16 bits
0x0002
FE186
unsigned 16 bits
0x0001
Y
Y
FE187
FE188
FE189
FE190
FE191
FE192
FE193
FE194
FE195
FE196
11-394
0x0002
W1 Hmc Der OP
unsigned 16 bits
0x0001
Y
Y
0x0002
W2 Hmc Der OP
unsigned 16 bits
0x0001
0x0002
W3 Hmc Der OP
unsigned 16 bits
0x0001
Hotst-Spot PKP
0x0002
Hotst-Spot OP
unsigned 16 bits
0x0001
0x0002
Aging Fctr OP
unsigned 16 bits
0x0001
0x0002
Xfmr LOL OP
unsigned 16 bits
0x0001
0x0002
Tap Ch Fail OP
0x0001
0x0002
unsigned 16 bits
0x0001
0x0002
TripCoil Mon 1 OP
unsigned 16 bits
0x0001
0x0002
TripCoil Mon 2 OP
unsigned 16 bits
0x0001
Y
Y
0x0002
TripCoil Mon 3 OP
unsigned 16 bits
0x0001
Code
FE197
FE198
FE199
FE200
FORMAT CODES
Type
Definition
0x0002
unsigned 16 bits
0x0001
0x0002
unsigned 16 bits
0x0001
0x0002
unsigned 16 bits
0x0002
BKR1 Arc OP
unsigned 16 bits
0x0002
BKR2 Arc OP
FE201
unsigned 16 bits
0x0002
BKR3 Arc OP
FE202
unsigned 16 bits
0x0001
0x0002
0x0008
0x0010
0x0020
0x0040
FE203
FE204
FE205
FE206
unsigned 16 bits
0x0001
0x0002
0x0008
0x0010
0x0020
Y
Y
0x0040
unsigned 16 bits
0x0001
0x0002
0x0008
0x0010
0x0020
0x0040
unsigned 16 bits
0x0001
0x0008
0x0010
0x0020
0x0040
0x0080
0x0100
unsigned 16 bits
0x0001
0x0008
0x0010
0x0020
11-395
FORMAT CODES
Code
FE208
FE209
FE210
FE211
FE212
FE213
FE214
Type
Definition
0x0040
0x0080
0x0100
unsigned 16 bits
0x0001
0x0002
unsigned 16 bits
Element Status: PF 1
0x0008
PF 1 Switch-In
0x0010
PF 1 Switch-Out
0x0040
PF 1 Switch-In OP
0x0080
PF 1 Switch-Out OP
unsigned 16 bits
Element Status: PF 2
0x0008
PF 2 Switch-In
0x0010
PF 2 Switch-Out
0x0040
PF 2 Switch-In OP
0x0080
PF 2 Switch-Out OP
unsigned 16 bits
0x0001
0x0008
0x0010
0x0020
unsigned 16 bits
0x0001
0x0008
0x0010
0x0020
unsigned 16 bits
0x0001
0x0008
0x0010
0x0020
unsigned 16 bits
0x0001
FE215
unsigned 16 bits
0x0001
FE216
unsigned 16 bits
0x0001
FE217
unsigned 16 bits
0x0008
FE218
11-396
0x0010
0x0020
0x0040
unsigned 16 bits
0x0008
Counter 1 LO
0x0010
Counter 1 EQL
0x0020
Counter 1 HI
0x0040
Counter 1 at Limit
FORMAT CODES
Code
Type
Definition
FE219
unsigned 16 bits
0x0008
Counter 2 LO
0x0010
Counter 2 EQL
0x0020
Counter 2 HI
FE220
FE221
FE222
FE223
FE224
FE225
FE226
FE227
FE228
0x0040
Counter 2 at Limit
unsigned 16 bits
0x0008
Counter 3 LO
0x0010
Counter 3 EQL
0x0020
Counter 3 HI
0x0040
Counter 3 at Limit
unsigned 16 bits
0x0008
Counter 4 LO
0x0010
Counter 4 EQL
0x0020
Counter 4 HI
0x0040
Counter 4 at Limit
unsigned 16 bits
0x0008
Counter 5 LO
0x0010
Counter 5 EQL
0x0020
Counter 5 HI
0x0040
Counter 5 at Limit
unsigned 16 bits
0x0008
Counter 6 LO
0x0010
Counter 6 EQL
0x0020
Counter 6 HI
0x0040
Counter 6 at Limit
unsigned 16 bits
0x0008
Counter 7 LO
0x0010
Counter 7 EQL
0x0020
Counter 7 HI
0x0040
Counter 7 at Limit
unsigned 16 bits
0x0008
Counter 8 LO
0x0010
Counter 8 EQL
0x0020
Counter 8 HI
0x0040
Counter 8 at Limit
unsigned 16 bits
0x0008
Counter 9 LO
0x0010
Counter 9 EQL
0x0020
Counter 9 HI
0x0040
Counter 9 at Limit
unsigned 16 bits
0x0008
Counter 10 LO
0x0010
Counter 10 EQL
0x0020
Counter 10 HI
0x0040
Counter 10 at Limit
unsigned 16 bits
0x0008
Counter 11 LO
11-397
FORMAT CODES
Code
FE229
FE230
FE231
FE232
FE233
FE234
FE235
FE236
FE237
FE238
FE239
FE240
11-398
Type
Definition
0x0010
Counter 11 EQL
0x0020
Counter 11 HI
0x0040
Counter 11 at Limit
unsigned 16 bits
0x0008
Counter 12 LO
0x0010
Counter 12 EQL
0x0020
Counter 12 HI
0x0040
Counter 12 at Limit
unsigned 16 bits
0x0008
Counter 13 LO
0x0010
Counter 13 EQL
0x0020
Counter 13 HI
0x0040
Counter 13 at Limit
unsigned 16 bits
0x0008
Counter 14 LO
0x0010
Counter 14 EQL
0x0020
Counter 14 HI
0x0040
Counter 14 at Limit
unsigned 16 bits
0x0008
Counter 15 LO
0x0010
Counter 15 EQL
0x0020
Counter 15 HI
0x0040
Counter 15 at Limit
unsigned 16 bits
0x0008
Counter 16 LO
0x0010
Counter 16 EQL
0x0020
Counter 16 HI
0x0040
Counter 16 at Limit
unsigned 16 bits
0x0001
0x0002
Harm Det 1 OP
unsigned 16 bits
0x0001
0x0002
Harm Det 2 OP
unsigned 16 bits
0x0001
0x0002
Harm Det 3 OP
unsigned 16 bits
0x0001
0x0002
Harm Det 4 OP
unsigned 16 bits
0x0001
0x0002
Harm Det 5 OP
unsigned 16 bits
0x0001
0x0002
Harm Det 6 OP
unsigned 16 bits
Code
FE241
FE242
FE243
FORMAT CODES
Type
Definition
0x0002
Start Inhibit
unsigned 16 bits
0x0040
Clear Events
0x0080
Clear Transient
0x0100
unsigned 16 bits
0x0002
Group 1 Active
unsigned 16 bits
0x0002
Group 2 Active
FE244
unsigned 16 bits
0x0002
Group 3 Active
FE245
unsigned 16 bits
0x0002
Group 4 Active
FE246
unsigned 16 bits
0x0002
Group 5 Active
unsigned 16 bits
0x0002
Group 6 Active
unsigned 16 bits
0x0001
0x0002
Thermal Inhibit OP
unsigned 16 bits
0x0001
0x0002
unsigned 16 bits
0x0001
0x0002
unsigned 16 bits
0x0001
Y
Y
FE247
FE248
FE249
FE250
FE251
FE252
FE253
FE254
FE255
FE256
FE257
0x0002
Restart Delay OP
unsigned 16 bits
0x0002
unsigned 16 bits
0x0002
unsigned 16 bits
Y
Y
0x0008
Local Mode ON
0x0010
0x0040
BKR1 Selected
0x0080
BKR2 Selected
0x0100
BKR3 Selected
Y
Y
unsigned 16 bits
0x0008
0x0010
unsigned 16 bits
0x0008
0x0010
unsigned 16 bits
0x0008
11-399
FORMAT CODES
Code
FE258
FE259
FE260
FE261
FE262
FE263
FE264
FE265
FE266
FE267
FE268
FE269
FE270
11-400
Type
Definition
0x0010
unsigned 16 bits
0x0008
0x0010
unsigned 16 bits
0x0008
0x0010
unsigned 16 bits
0x0008
0x0010
unsigned 16 bits
0x0001
0x0002
Trip Bus 1 OP
unsigned 16 bits
0x0001
0x0002
Trip Bus 2 OP
unsigned 16 bits
0x0001
0x0002
Trip Bus 3 OP
unsigned 16 bits
0x0001
0x0002
Trip Bus 4 OP
unsigned 16 bits
0x0001
0x0002
Trip Bus 5 OP
unsigned 16 bits
0x0001
0x0002
Trip Bus 6 OP
unsigned 16 bits
0x0002
BF1 OP
0x0008
BF1 Retrip
0x0010
BF1 Highset OP
0x0020
BF1 Lowset OP
0x0040
unsigned 16 bits
0x0002
BF2 OP
0x0008
BF2 Retrip
0x0010
BF2 Highset OP
0x0020
BF2 Lowset OP
0x0040
unsigned 16 bits
0x0002
BF3 OP
0x0008
BF3 Retrip
0x0010
BF3 Highset OP
0x0020
BF3 Lowset OP
0x0040
unsigned 16 bits
Code
FE272
FE273
FE275
FE276
FE277
FE278
FE279
FE280
FORMAT CODES
Type
Definition
0x0002
0x0008
0x0010
0x0020
0x0040
0x0080
0x0100
Sync1 OK
unsigned 16 bits
0x0002
unsigned 16 bits
0x0001
0x0002
Cold Load 1 OP
unsigned 16 bits
0x0001
Ph UV Restore PKP
0x0008
0x0040
Aux UV Restore OP
0x0080
Ph UV Restore OP
0x0100
UV Restore Init
unsigned 16 bits
0x0001
UF Restore PKP
0x0002
UF Restore OP
0x0040
UF Restore Init
unsigned 16 bits
0x0001
0x0002
0x0004
0x0008
0x0010
0x0020
0x0040
0x0080
Tie-BKR Conn&Clsd
Y
Y
0x0100
unsigned 16 bits
0x0002
Transfer Initiated
unsigned 16 bits
0x0001
AR1 Disabled
0x0008
AR1 Enabled
0x0010
AR1 Initiated
0x0020
AR1 In Progress
0x0040
AR1 Close
0x0080
AR1 Lockout
0x0100
unsigned 16 bits
0x0008
0x0010
0x0020
0x0040
11-401
FORMAT CODES
Code
FE281
FE282
FE287
FE289
FE290
FE291
FE292
FE293
FE294
FE295
FE296
FE297
FE298
FE299
FE300
11-402
Type
Definition
0x0080
unsigned 16 bits
0x0008
AR1 ShotRdc to 1
0x0010
AR1 ShotRdc to 2
0x0020
AR1 ShotRdc to 3
0x0040
AR1 ShotRdc to LO
unsigned 16 bits
0x0008
0x0010
0x0020
AR1 Coordinating
unsigned 16 bits
0x0002
VT Fuse Fail1 OP
0x0008
VT Fuse1 V Loss
unsigned 16 bits
0x0002
NV Latch 1 ON
0x0004
NV Latch 1 OFF
unsigned 16 bits
0x0002
NV Latch 2 ON
0x0004
NV Latch 2 OFF
unsigned 16 bits
0x0002
NV Latch 3 ON
0x0004
NV Latch 3 OFF
unsigned 16 bits
0x0002
NV Latch 4 ON
0x0004
NV Latch 4 OFF
unsigned 16 bits
0x0002
NV Latch 5 ON
0x0004
NV Latch 5 OFF
unsigned 16 bits
0x0002
NV Latch 6 ON
0x0004
NV Latch 6 OFF
unsigned 16 bits
0x0002
NV Latch 7 ON
0x0004
NV Latch 7 OFF
unsigned 16 bits
0x0002
NV Latch 8 ON
0x0004
NV Latch 8 OFF
unsigned 16 bits
0x0002
NV Latch 9 ON
0x0004
NV Latch 9 OFF
unsigned 16 bits
0x0002
NV Latch 10 ON
0x0004
NV Latch 10 OFF
unsigned 16 bits
0x0002
NV Latch 11 ON
0x0004
NV Latch 11 OFF
unsigned 16 bits
Code
FE301
FE302
FE303
FE304
FE305
FE306
FE307
FE308
FE309
FORMAT CODES
Type
Definition
0x0002
NV Latch 12 ON
0x0004
NV Latch 12 OFF
unsigned 16 bits
0x0002
NV Latch 13 ON
0x0004
NV Latch 13 OFF
unsigned 16 bits
0x0002
NV Latch 14 ON
0x0004
NV Latch 14 OFF
unsigned 16 bits
0x0002
NV Latch 15 ON
0x0004
NV Latch 15 OFF
unsigned 16 bits
0x0002
NV Latch 16 ON
0x0004
NV Latch 16 OFF
unsigned 16 bits
0x0001
FlexEl 1 PKP
0x0002
FlexEl 1 OP
unsigned 16 bits
0x0001
FlexEl 2 PKP
0x0002
FlexEl 2 OP
unsigned 16 bits
0x0001
FlexEl 3 PKP
0x0002
FlexEl 3 OP
unsigned 16 bits
0x0001
FlexEl 4 PKP
0x0002
FlexEl 4 OP
unsigned 16 bits
0x0001
FlexEl 5 PKP
0x0002
FlexEl 5 OP
unsigned 16 bits
0x0001
FlexEl 6 PKP
0x0002
FlexEl 6 OP
unsigned 16 bits
0x0001
FlexEl 7 PKP
0x0002
FlexEl 7 OP
unsigned 16 bits
0x0001
FlexEl 8 PKP
0x0002
FlexEl 8 OP
FE313
unsigned 16 bits
0x0002
Hot RTD
FE314
unsigned 16 bits
0x0001
RTD 1 PKP
FE310
FE311
FE312
FE315
0x0002
RTD 1 OP
0x0040
RTD 1 Open
0x0080
RTD 1 Shorted
unsigned 16 bits
0x0001
RTD 2 PKP
11-403
FORMAT CODES
Code
FE316
FE317
FE318
FE319
FE320
FE321
FE322
FE323
FE324
11-404
Type
Definition
0x0002
RTD 2 OP
0x0040
RTD 2 Open
Y
Y
0x0080
RTD 2 Shorted
unsigned 16 bits
0x0001
RTD 3 PKP
0x0002
RTD 3 OP
0x0040
RTD 3 Open
0x0080
RTD 3 Shorted
unsigned 16 bits
0x0001
RTD 4 PKP
0x0002
RTD 4 OP
0x0040
RTD 4 Open
0x0080
RTD 4 Shorted
unsigned 16 bits
0x0001
RTD 5 PKP
0x0002
RTD 5 OP
0x0040
RTD 5 Open
0x0080
RTD 5 Shorted
unsigned 16 bits
0x0001
RTD 6 PKP
0x0002
RTD 6 OP
0x0040
RTD 6 Open
0x0080
RTD 6 Shorted
unsigned 16 bits
0x0001
RTD 7 PKP
0x0002
RTD 7 OP
0x0040
RTD 7 Open
0x0080
RTD 7 Shorted
unsigned 16 bits
0x0001
RTD 8 PKP
0x0002
RTD 8 OP
0x0040
RTD 8 Open
0x0080
RTD 8 Shorted
unsigned 16 bits
0x0001
RTD 9 PKP
0x0002
RTD 9 OP
0x0040
RTD 9 Open
0x0080
RTD 9 Shorted
unsigned 16 bits
0x0001
RTD 10 PKP
0x0002
RTD 10 OP
0x0040
RTD 10 Open
0x0080
RTD 10 Shorted
unsigned 16 bits
0x0001
RTD 11 PKP
0x0002
RTD 11 OP
0x0040
RTD 11 Open
Code
FE325
FE326
FE332
FE333
FE334
FE335
FE336
FE337
FE338
FE339
FE340
FE341
FE342
FE343
FORMAT CODES
Type
Definition
0x0080
RTD 11 Shorted
unsigned 16 bits
0x0001
RTD 12 PKP
0x0002
RTD 12 OP
0x0040
RTD 12 Open
0x0080
RTD 12 Shorted
unsigned 16 bits
0x0001
RTD 13 PKP
0x0002
RTD 13 OP
0x0040
RTD 13 Open
0x0080
RTD 13 Shorted
unsigned 16 bits
0x0001
0x0002
RTD 1 Alarm OP
unsigned 16 bits
0x0001
0x0002
RTD 2 Alarm OP
unsigned 16 bits
0x0001
0x0002
RTD 3 Alarm OP
unsigned 16 bits
0x0001
0x0002
RTD 4 Alarm OP
unsigned 16 bits
0x0001
0x0002
RTD 5 Alarm OP
unsigned 16 bits
0x0001
0x0002
RTD 6 Alarm OP
unsigned 16 bits
0x0001
0x0002
RTD 7 Alarm OP
unsigned 16 bits
0x0001
0x0002
RTD 8 Alarm OP
unsigned 16 bits
0x0001
0x0002
RTD 9 Alarm OP
unsigned 16 bits
0x0001
0x0002
RTD 10 Alarm OP
unsigned 16 bits
0x0001
0x0002
RTD 11 Alarm OP
unsigned 16 bits
0x0001
0x0002
RTD 12 Alarm OP
11-405
FORMAT CODES
Code
Type
Definition
FE344
unsigned 16 bits
0x0001
FE386
FE387
FE388
FE389
FE398
FE399
FE400
FE401
FE412
FE413
FE414
FE415
FE416
FE417
FE418
11-406
0x0002
RTD 13 Alarm OP
unsigned 16 bits
0x0001
Anlg Ip 1 PKP
0x0002
Anlg Ip 1 OP
unsigned 16 bits
0x0001
Anlg Ip 2 PKP
0x0002
Anlg Ip 2 OP
unsigned 16 bits
0x0001
Anlg Ip 3 PKP
0x0002
Anlg Ip 3 OP
unsigned 16 bits
0x0001
Anlg Ip 4 PKP
0x0002
Anlg Ip 4 OP
unsigned 16 bits
0x0001
0x0002
Anlg Ip 1 Alrm OP
unsigned 16 bits
0x0001
Y
Y
0x0002
Anlg Ip 2 Alrm OP
unsigned 16 bits
0x0001
Y
Y
0x0002
Anlg Ip 3 Alrm OP
unsigned 16 bits
0x0001
0x0002
Anlg Ip 4 Alrm OP
unsigned 16 bits
0x0001
Fast UF 1 PKP
0x0002
Fast UF 1 OP
unsigned 16 bits
0x0001
Fast UF 2 PKP
0x0002
Fast UF 2 OP
unsigned 16 bits
0x0001
Fast UF 3 PKP
0x0002
Fast UF 3 OP
unsigned 16 bits
0x0001
Fast UF 4 PKP
0x0002
Fast UF 4 OP
unsigned 16 bits
0x0001
Fast UF 5 PKP
0x0002
Fast UF 5 OP
unsigned 16 bits
0x0001
Fast UF 6 PKP
0x0002
Fast UF 6 OP
unsigned 16 bits
0x0001
Fast UF 7 PKP
Code
FE419
FE420
FE421
FE423
FE424
FE438
FE439
FE441
FE442
FE443
FE444
FE445
FE446
FE447
FORMAT CODES
Type
Definition
0x0002
Fast UF 7 OP
unsigned 16 bits
0x0001
Fast UF 8 PKP
0x0002
Fast UF 8 OP
unsigned 16 bits
0x0002
Arc Flash 1 OP
unsigned 16 bits
0x0001
AF 1 Light 1 PKP
0x0008
AF 1 Light 2 PKP
0x0010
AF 1 Light 3 PKP
0x0020
AF 1 Light 4 PKP
unsigned 16 bits
0x0001
0x0008
AF 1 HS Ph IOC PKP A
0x0010
AF 1 HS Ph IOC PKP B
0x0020
AF 1 HS Ph IOC PKP C
unsigned 16 bits
0x0002
Arc Flash 1 S1 OP
0x0040
Arc Flash 1 S2 OP
0x0080
Arc Flash 1 S3 OP
0x0100
Arc Flash 1 S4 OP
unsigned 16 bits
0x0002
unsigned 16 bits
0x0002
0x0040
0x0080
0x0100
unsigned 16 bits
0x0001
Offline
0x0002
Online
Y
Y
0x0008
Tripped
unsigned 16 bits
0x0002
Run Hrs OP
unsigned 16 bits
0x0001
Y
Y
0x0002
unsigned 16 bits
0x0001
Y
Y
0x0002
unsigned 16 bits
0x0001
Y
Y
0x0002
unsigned 16 bits
0x0001
0x0002
unsigned 16 bits
11-407
FORMAT CODES
Code
FE448
FE449
FE450
FE451
FE452
FE453
FE454
FE455
FE456
FE457
FE458
FE459
11-408
Type
Definition
0x0001
0x0002
unsigned 16 bits
0x0001
Y
Y
0x0002
unsigned 16 bits
0x0001
Y
Y
0x0002
unsigned 16 bits
0x0001
Unbal PKP
0x0002
Unbal OP
0x0004
Unbal DPO
unsigned 16 bits
0x0001
0x0002
Unbal Alarm OP
unsigned 16 bits
0x0001
0x0002
Inadv Energ OP
unsigned 16 bits
0x0001
Offline OC PKP
0x0002
Offline OC OP
0x0008
Offline OC PKP A
0x0010
Offline OC PKP B
0x0020
Offline OC PKP C
0x0040
Offline OC OP A
0x0080
Offline OC OP B
0x0100
Offline OC OP C
unsigned 16 bits
0x0001
0x0002
unsigned 16 bits
0x0001
0x0002
Seq Shtdn OP
unsigned 16 bits
0x0008
0x0010
0x0040
Pos Mvar OP
0x0080
Neg Mvar OP
unsigned 16 bits
0x0008
0x0010
0x0040
0x0080
unsigned 16 bits
0x0001
0x0002
3rd Ntr UV OP
unsigned 16 bits
Code
FE460
FE461
FE462
FE463
FE464
FE465
FE466
MODBUS COMMANDS
Type
Definition
0x0001
0x0002
unsigned 16 bits
0x0001
Y
Y
0x0002
3rd V Dif OP
unsigned 16 bits
0x0001
Y
Y
0x0002
unsigned 16 bits
0x0001
0x0002
LOE Circle 1 OP
unsigned 16 bits
0x0001
0x0002
LOE Circle 2 OP
unsigned 16 bits
0x0002
OOS OP
0x0008
0x0010
Y
Y
0x0020
unsigned 16 bits
0x0001
Thermal OL PKP
0x0002
Thermal OL OP
unsigned 16 bits
0x0008
0x0010
0x0040
Y
Y
0x0080
FE467
unsigned 16 bits
0x0002
DGA Alarm OP
FE468
unsigned 16 bits
0x0008
Device 1 Offline
Y
Y
Modbus Commands
Command Value Description
850
869
889
845
None
Reset
Open
Close
Open2
Close2
Open3
Close3
ChangeToSetpointGroup1
Y
Y
11-409
MODBUS COMMANDS
11-410
850
869
889
845
10
ChangeToSetpointGroup2
11
ChangeToSetpointGroup3
12
ChangeToSetpointGroup4
13
ChangeToSetpointGroup5
14
ChangeToSetpointGroup6
15
Active Group
18
Local
19
Remote
96
97
Clear Targets
98
Clear Events
99
100
Clear DataLogger
101
102
103
104
105
107
108
109
110
111
112
113
122
123
RTD Maximums
124
126
134
USER PushButton 1
135
USER PushButton 2
136
USER PushButton 3
137
Start Inhibit
153
LED Test
154
Force LEDs
199
MotorDLogClear
200
MotorDLogStart
201
MotorDLogStop
202
Trigger Waveform
210
Clear Autoreclose
211
213
214
215
216
217
218
Y
Y
Y
Y
MODBUS COMMANDS
850
869
889
845
219
220
221
222
223
224
4096
4097
4098
4099
Y
Y
Y
4100
4101
4102
4103
4104
4105
4106
4107
4108
4109
4110
4111
4112
4113
4114
4115
4116
4117
4118
4119
4120
4121
4122
4123
4124
4125
4126
4127
Y
Y
11-411
MODBUS COMMANDS
11-412
GE
Grid Solutions
Appendix A includes information about the RADIUS server and certificates followed by an
example of how to set up a simple RADIUS server and certificate management.
Create a CA and
Server Certificates
-->
A-A-1
Authentication:
The user initiates the authentication process by providing user credentials. The 8 Series
unit then tries to establish a trust relationship with the RADIUS server. The RADIUS server
identifies itself via a certificate which it sends to the 8 Series unit. This certificate holds the
servers information:
version
public key
subject
serial number
valid from
valid until
key-usage
signature algorithm
The 8 Series unit then validates the servers identity by verifying the servers certificate
against the CA certificate that it has. If both the server and CA certificates are signed by
the same trusted authority (CA), a client side trust relationship is successfully established.
Create a Certificate
Request for the Server
While using the command, you are asked to enter the following information that is
incorporated into the certificate request.
A-A-2
Country Name
Locality Name
Common Name
Email Address
What you enter here is called a Distinguished Name or a DN. All this information is sent
with the certificate request, see figure A-1. The two 'extra' attributes ("A challenge
password" and "An optional company name") are left blank for this example.
Figure A-1: Enter DN information for Certificate request
Create a Signed
Certificate for the
Server
CA certificates (assuming it to be your root certificate from CA) are created and later used
to sign the servers certificate request.
1.
2.
While using the above command, you are asked to enter information that is incorporated
into your certificate. Please make sure that while entering this information (as depicted in
the previous step) that the Common Name (CN) of the CA and the Server certificate do NOT
match. This avoids naming collisions and other related errors later on.
3.
Use the servers certificate request (server.csr) that was created as described in the
previous section (see Create a Certificate Request for the Server) and sign it with the
CA. Use the following command:
A-A-3
-req
With this option, a certificate request is expected instead of the certificate (by
default).
-in
-CA
-CAkey
When the -CA option is used to sign a certificate, it uses a serial number specified in a
file. This file consists of one line containing an even number of hex digits with the
serial number to use. After each use, the serial number is incremented and written out
to the file again.
-set_serial
-out
days
server.key
server.crt
ca.crt
onto the FreeRADIUS.net server under the directory containing the certificates.
In this example the directory is located under the path:
<Path_to_Radius>\etc\raddb\certs\FreeRADIUS.net\DemoCerts>
CLIENTS.CONF
Add the clients in the clients.conf file.
The file is available under the <Path_to_Radius>\etc\raddb directory.
A-A-4
The following text defines a RADIUS client 8 Series unit with the assumption that its IPaddress is 10.0.0.2 and subnet mask is 255.255.255.0. The secret that is specified here is
also configured on the 8 Series unit for successful authentication. The shortname is a
short alias that can be used in place of the IP address and it is optional.
client 10.0.0.2/24 {
secret = testing123
shortname = private-network-1
}
DICTIONARY.GE
Create a file called dictionary.ge under the <Path_to_Radius>\etc\raddb directory and
add the following content to it:
# ##########################################################
#
GE VSAs
############################################################
VENDOR
GE
2910
# Management authorization
BEGIN-VENDOR
GE
# Role ID
ATTRIBUTE
GE-UR-Role
integer
# GE-UR-ROLE values
VALUE
GE-UR-Role
Administrator
VALUE
GE-UR-Role
Supervisor
VALUE
GE-UR-Role
Engineer
VALUE
GE-UR-Role
Operator
VALUE
GE-UR-Role
Observer
END-VENDOR
1
2
GE
#############################################################
DICTIONARY
Add the following line to the dictionary file present under <Path_to_Radius>\etc\raddb.
$INCLUDE dictionary.ge
EAP.CONF
The eap.conf file is available under the <Path_to_Radius>\etc\raddb directory.
Locate the tls block and add the respective entries as shown in figure A-2 to the
private_key_file, certificate_file and CA_file fields.
A-A-5
Move the DER file (ca.der) to the 8 Series unit by using SFTP.
The path on the 8 Series unit is /net/MainShare
Finally, update the Remote RADIUS shared secret (as set up in clients.conf) using the
EnerVista 8 Series Setup software.
A-A-6
GE
Grid Solutions
Warranty
For products shipped as of 1 October 2013, GE warrants most of its GE manufactured
products for 10 years. For warranty details including any limitations and disclaimers, see
our Terms and Conditions at https://www.gegridsolutions.com/multilin/warranty.htm
For products shipped before 1 October 2013, the standard 24-month warranty applies.
Revision history
Table B-1: Revision History
MANUAL P/N
RELEASE DATE
1601-0702-A1
March 2016
1601-0702-A2
April 2016
Major Updates
Table B-2: Major Updates for 8 Series Communications A2
PAGE NUMBER
CHANGES
Chapter 11
B-B-1
REVISION HISTORY