SOP on usage of Dynamic pass box 0

BY PHARMACEUTICAL GUIDANACE ON AUGUST 18, 2016 PRODUCTION, SOP

Objective:To lay down a procedure on usage of Dynamic pass box.


Scope:
This SOP is applicable for usage of Dynamic pass box in formulation plant of pharmaceutical
company.
Responsibility:
Production Officer / Executive shall be responsible for follow the procedure mentioned in this SOP.
Accountability:
Production Head and QA Head shall be accountable for compliance of SOP.
Procedure: FACEBOOK

The usage of dynamic pass boxes depend on area in which installed ,For eg. four dynamic pass
boxes as per respective aseptic area is described herein:
Dynamic Pass Box (01) It is used for material transfer from controlled area to cooling area. The
following items used in aseptic area are transferred through Dynamic Pass Box:
Goggles, Media Plates, Sampling Aids, Aspirator Container with hosepipe, Pre-filters of Laminar Air
Like Page Contact Us
Flow,Disinfactant spray bottles, PAO apparatus, particle counter, Filter integrity test apparatus,
weighing balance, marker pen, air sampler, tool box. Any other item to be used inside Aseptic area Be the first of your friends to like this
is to be transferred after taking permission of the Production officer.
Dynamic Pass Box (02) It is used for transfer of material from cooling zone to vial filling room.
The following items used in aseptic area are transferred through Dynamic Pass Box :
Media Plates, Sampling Aids, Aspirator Container with hosepipe, Pre-filters of Laminar Air Flow,
Disinfectant spray bottles, PAO apparatus, particle counter, Filter integrity test apparatus, weighing P.E.W.E.,LLC
balance, marker pen, air sampler, tool box,filling and bunging machine change parts. Any other item
to be used inside Aseptic area is to be transferred after taking permission of the Production officer.
Wastewater Treatment
Dynamic Pass Box(03) It is used for transfer of sanitized Aluminum seals, sealing machine
TSS,BOD,Oil
DAF,Screen,Clarifier,Filter
change parts, Media Plates and Sampling Aids,Pre-filters of Laminar Air Flow, Disinfectant spray
Press
bottles, PAO apparatus, marker pen, air sampler and tools box. Any other item to be transferred
only after taking permission of the Production officer.
Dynamic Pass Box (04) It is used for transfer of sterile raw material container, sampling aids
from IRM Room to sampling room. Any other item to be used inside Aseptic area is to be
transferred after taking permission of the Production officer.
Operation of Dynamic Pass Box (01)
FIND US ON GOOGLE PLUS
Ensure that the power supplies of Dynamic pass box are connected.
Clean and sanitize the entire dynamic pass box from aseptic area side with lint free duster soaked
in 70 percent Isopropyl Alcohol.
Ensure that no material is present in the pass box and both the doors of pass box are closed.
Switch ON the pass box from the electric board and Check that the Ultraviolet light is properly
working
Check that interlocking of door is properly working.
Switch ON from the Mains to start the blower of pass box and check the reading on megnehelic
gauge .It should be within range of 8 mm to 15 mm of water.
Clean and sanitize the item to be transferred with lint free duster soaked in 20 % Virosil Pharma.
Open the door of dynamic pass box from controlled area side. Load the items to be transferred to
aseptic area and close the door.
Keep the items to be transferred under UV light inside the pass box for at least 30 minutes.
Inform the person on the other side for unloading the items in aseptic area.
Open the door of dynamic pass box from aseptic area side, unload the items and close the door.
Operation of Dynamic Pass Box Pharmaceutical Guidance
Ensure that the power supplies of Dynamic pass box are connected.
Seguir
Clean and sanitize the entire dynamic pass box from cooling zone and vial filling room side with lint
92 seguidores
free duster soaked in 70 percent Isopropyl Alcohol.
Ensure that no material is present in the pass box and both the door of pass box are closed.
Switch ON from the electric board and Check that the Ultraviolet light of Dynamic pass box is
working properly.
Check the interlocking of door is properly working
Switch ON from the Mains to start the blower of pass box and check the reading on Megnehelic
gauge .It should be within range of 8 mm to 15 mm of water.
Open the door of dynamic pass box from cooling area. Load the items to be transferred to aseptic
area and close the door.
Inform the person on the other side for unloading the items in vial filling room.
For unloading the item in vial filling room open the door and unload the items. Close the door
immediately after unloading.
Transfer the items to their respective storage places in vial filling room.
Operation of Dynamic Pass Box (03)
Ensure that the power supplies of Dynamic pass box are connected.
Clean and sanitize the entire dynamic pass box from vial sealing room side and corridor side with
lint free duster soaked in 70 percent Isopropyl Alcohol.
Ensure that no material present in the pass box and both the door of pass box are closed.
Switch ON from the electric board and Check that the Ultraviolet light of Dynamic pass box is
properly working.
Check the interlocking of door is properly working.
Switch ON from the Mains to start the blower of pass box and check the reading on Megnehelic
gauge .It should be within range of 8 mm to 15 mm of water.
Open the door of dynamic pass box from corridor side and load the items to be transferred to vial
sealing room and close the door.
Keep the items to be transferred under UV light inside the pass box for at least 30 minutes.
Inform the person on the other side for unloading the items in vial sealing room.
Open the door of dynamic pass box from vial sealing room, unload the items, and close the door.
Operation of Pass Box [04]
Ensure that the power supplies of Dynamic pass box are connected.
Clean and sanitize the entire dynamic pass box from IRM store side and sampling room side with
lint free duster soaked in 70 percent Isopropyl Alcohol.
Ensure that no material present in the pass box and both the door of pass box are closed.
Switch ON from the electric board and Check that the Ultraviolet light of Dynamic pass box is
properly working.
Check the interlocking of door is properly working.
Switch ON the Mains to start the blower of pass box and check the reading of megnehelic gauge
should be within range.
Clean and sanitize the outer surface of Raw material container to be transferred with lint free
duster soaked in 20 percent Virosil Pharma.
Open the door of dynamic pass box from IRM store side and load the sterile raw material container
to be transferred to sampling room and close the door.
Keep the containers to be transferred under UV light inside the pass box for at least 30 minutes.
Inform the person on the other side for unloading the items in sampling room.
Open the door of dynamic pass box from sampling room side and unload the containers.
Immediately close the doors after unloading the containers.
Record the details of items transferred through dynamic pass box in check list for material
transferred through dynamic pass box.
Record the details of UV light burning in the format for Burning hours of U.V Lights specimen
attached with Annexure-I.
Record the readings of differential pressure in the format for differential pressure monitoring
record.
List of Annexure / Format
Burning hours of U.V Lights -Annexure-I
Reason for revision
New SOP.
Abbreviations
IPA : Isopropyl alcohol
IRM : Intermediate raw material
UV : Ultra Violet

Annexure-I
Burning hours of U.V Lights

Pass box ID No of burning Cumulative burning Done by Checked by Remarks


No hours hours

Sharing

Controlador Embebido
Nuestra plataforma embebida es robusta, confiable y reconfigurable

ABOUT AUTHOR

PHARMACEUTICAL GUIDANACE

RELATED POSTS

AUGUST 24, 2016 0 JULY 31, 2016 0 JULY 31, 2016 0

SOP On Process Simulation by SOP on Control of Sieves and SOP on Control of Change Parts of
Media Fill study Screens of Different Equipments Machines/Equipments

LEAVE A REPLY

Your Comment

Your Name

Your Email

Your Website
POST COMMENT

GO BACK

ABOUT RECENT POST SHARING

Pharmaceutical Guidance Performance Qualification Protocol of Tunnel Sterilizer

SOP on Quality Risk Management


Pharma Guidance is Indias online complete Pharma
solution platform, where people can connect with each
other to share knowledge, buy the required Pharma
related Document .The vision is to support the all
manufacturers of pharmaceutical company to prepared
the current and update document to complies the cGMP
norms and also give the updated knowledge to new
Pharma beginner.

Copyright 2016 - Pharmaceutical Guidance by Sainssoft Technology

You might also like