8 7 6 5 4 3 2 1

RACK FRONT 10.00 7.40


3.0 X 8.0 PLATES TYP TYP
FOR CABLE ENTRY

F
F
30.64
10.75
3.0 X 8.0 PLATES
FOR CABLE ENTRY
21.50 28.32

BOTTOM VENTILATION
NOT SHOWN IN BOTTOM VIEW .56
23.30 23.30
E E
1.50

BOTTOM VIEW

49.60 24.80 24.80

D D

VENTILATION LOUVERS

84.00
C
C

B
B

FRONT VIEW REAR VIEW

RACK NOTES:

1. EMPTY RACK WEIGHT: 720 LBS. TOTAL WEIGHT (2 RACKS) ONE 480V STRING.
2. FULLY WELDED FRAME. MANUFACTURED FROM HEAVY GAUGE STEEL.
A 3. POWDER COATED WITH A CORROSION RESISTANT, EPOXY HYBRID POWDER USING A UNLESS OTHERWISE SPECIFIED: 3233 W. Kingsley Rd.
Ste. 200 A
FIVE STAGE EMERSION PRETREATMENT PROCESS. DIMENSIONS ARE IN INCHES
TOLERANCES:
ESS ELECTRONIC SYSTEM SUPPORT
888-475-9292 www.ess.to
Garland, Texas 75041
PH. 972-272-2468
4. BATTERIES CAN BE ACCESSED FROM FRONT, REAR, AND BOTH SIDES. ANGULAR: MACH .5 BEND 1
FAX 972-276-9844

5. CUSTOM DESIGNED PALLETS FOR SHIPPING ANYWHERE, LOCALLY AND GLOBALLY (UPON REQUEST).
TWO PLACE DECIMAL .02
THREE PLACE DECIMAL .01
NAME DATE TITLE:
BATTERY RACK, 16V FT,
6. BATTERY RACK CAN BE MOVED WITH A NORMAL PALLET JACK FROM FRONT AND REAR.
DRAWN RNA 3-6-13
PROPRIETARY AND CONFIDENTIAL
PROJECTION:
CHECKED
480V, 5 TIER, TOP BRKR.
7. STANDARD AND CUSTOM SPILL CONTAINMENT OPTIONS ARE AVAILABLE. THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
MATERIAL
SEE NOTE 1
ENG APPR. SIZE DWG. NO. REV
ELECTRONIC SYSTEMS SUPPORT. ANY
REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OF
ELECTRONIC SYSTMES SUPPORT IS USED ON
FINISH
SEE NOTE 2
MFG APPR.

Q.A.
D EFR5A-SPEC A
PROHIBITED. DO NOT SCALE DRAWING SCALE: 1:16 WEIGHT: SHEET 1 OF 2
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1

BREAKER DETAIL BATTERYRACKPARTNUMBERGUIDE


RACKPARTNUMBER DESCRIPTION
OUTPUT TO UPS EFR5A A A

F TO BREAKER OR + - BASEPARTNUMBER F

FUSE PANEL
RACKHEIGHT

- +
FROM BATTERY POS.
RACKCOLOR

FROM BATTERY NEG.


BATTERYCONFIGURATIONTABLE
MAXIMUMNUMBEROF
GND
BATTERYMANUFACTURER
BATTERIESPERRACK

E - + - + - + - + - + - +
BREAKER ENERSYS E

BRACKET BATTERYMODEL 16HX800FFR


30
NUMBER 16HX925FFR

FROM BREAKER OPTIONS HEIGHTLEGEND COLORLEGEND


HEIGHT(INCHES) AVAILABILITY **A=BLACK
**A=84.00 INSTOCK B=BEIGE
TO
- + - + - + - + - + - + 24/48/120 VDC B=82.00 N/A C=LIEBERTGRAY
SOUCE C=80.00 N/A

BLUE/YELLOW
BLUE/YELLOW
D=MITSUBISHIBEIGE
D=79.0 N/A E=MGEWHITE

YELLOW
E=78.7 N/A

YELLOW
F=TOSHIBABLACK

BLACK
BLACK
F=78.4 N/A

BLUE
BLUE
D G=GEWHITE D
G=78.0 N/A H=LIEBERTBLACK
H=77.3 N/A J=EATONBLACK
J=76.8 N/A K=TBD
- + - + - + - + - + - + K=75.3 N/A
L=75.0 N/A **BLACKISESSSTANDARDCOLOR
M=74.8 N/A ANDWILLBEINSTOCK**
N=73.5 N/A LETTERSSTATING"TBD"AREOPEN
FORCUSTOMCOLORSNOTLISTED.
P=72.0 N/A PLEASECONSULTWITHSALES
Q=71.7 N/A STAFFFORFURTHERINFO.
R=70.9 N/A
S=TBD N/A

NO
COMMON
NO
FROM UPS

NC

NC
COMMON
TO UPS
- + - + - + - + - + - +
T=TBD N/A C
C

**84.0ISTHESTANDARDHEIGHTFORTHEEFR5A
RACKS.SHORTERHEIGHTSARENOTAVAILABLE**
PLEASECONSULTWITHSALESSTAFFFORFURTHER
INFO.

TO UPS
- + - + - + - + - + - +
AUXILLARY CONTACTS LISTED APPLICABLE WHEN
BREAKER IS IN THE CLOSED (ON) POSITION

B
FUSE OPTION B
PART NUMBER GUIDE:
FUSE PANEL
1. REFERENCE THE BATTERY PART NUMBER GUIDE TABLE WHEN ORDERING A RACK.
2. THE BASE NUMBER WILL ALWAYS BE THE SAME. HOWEVER, 2 ALPHA DIGITS WILL
FOLLOW THE BASE NUMBER INDICATING THE HEIGHT AND COLOR OF THE RACK.
FROM BATTERY POS. FUSE TERMINAL + OUTPUT 3. REFERENCE THE "HEIGHT LEGEND" TABLE AND THE "COLOR LEGEND" TABLE IN ORDER
TO DETERMINE THE 2 ALPHA DIGITS NEEDED TO COMPLETE YOUR ORDER.
ELECTRICAL NOTES: BLOCK - TO UPS 4. EXAMPLE: EFR5AAA - THIS REPRESENTS A STANDARD EFR5A RACK, 84.0 INCH HEIGHT
FROM BATTERY NEG. WITH A POWDER COAT FINISH OF STANDARD BLACK.
5. THE EFR5A RACK IS NOT AVAILABLE IN OTHER HEIGHTS OTHER THAT 84.0 INCHES.
1. ALL CABLES ARE UL LISTED.
GND.
2. ALL BREAKERS ARE UL RECOGNIZED.
A 3. ALL FUSES ARE UL RECOGNIZED, TYPE A50P, A70P OR EQUIVALENT. UNLESS OTHERWISE SPECIFIED: 3233 W. Kingsley Rd.

ALWAYS REPLACE WITH SAME TYPE OR ITS EQUIVALENT. DIMENSIONS ARE IN INCHES
ESS ELECTRONIC SYSTEM SUPPORT
888-475-9292 www.ess.to
Ste. 200
Garland, Texas 75041
A

4. TERMINAL BLOCKS ARE UL RECOGNIZED, 600V RATED.


TOLERANCES:
PH. 972-272-2468
ANGULAR: MACH .5 BEND 1
FAX 972-276-9844

5. RACKS ARE SHIPPED WITH THE BREAKER IN THE TRIPPED POSITION. TWO PLACE DECIMAL .02
THREE PLACE DECIMAL .01
NAME DATE TITLE:
BATTERY RACK, 16V FT,
6. RACK GROUND CONNECTION IS A 5/16-18 THREADED STUD.
DRAWN RNA 3-6-13
PROPRIETARY AND CONFIDENTIAL
PROJECTION:
CHECKED 480V, 5 TIER, TOP BRKR.
7. CABLES BETWEEN BATTERY RACK TO UNINTERRUPTIBLE POWER SUPPLY ARE OPTIONAL. THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
MATERIAL
SEE NOTE 1
ENG APPR. SIZE DWG. NO. REV
ELECTRONIC SYSTEMS SUPPORT. ANY
REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OF
ELECTRONIC SYSTMES SUPPORT IS USED ON
FINISH
SEE NOTE 2
MFG APPR.

Q.A.
D EFR5A-SPEC A
PROHIBITED. DO NOT SCALE DRAWING SCALE: 1:16 WEIGHT: SHEET 2 OF 2
8 7 6 5 4 3 2 1