You are on page 1of 4
Saraswati Cables & Allied Industries Is 1554-1 _1S694 50} (Sr em/ciat2i2s CM/. 1303926 QUALITY ENGINEERING SINCE 1982 Saraswati Cables, located on a spacious 6000 m’ plot in the serene foothills of the Shivalik range in Una in Himachal Pradesh( adjacent to famous Bhakra- Nangal Dam) was established in 1982 under the able leadership of Mr. Madan Mohan Singh, a former scientist at the Bhabha Atomic Research Centre, Mumbai. It was a glorious moment in the career of the company, when in 1987 it was selected to supply the en- tire High Speed Data Communication Cable needs of the Missile Test Range at Chandipur (Odisha) under the Ministry of Defence, Government of India, against stiff competition from the best names in the industry. This contribution of the company helped significantly in the successful launch of our country’s first Intermediate Range Ballistic Missile ‘AGNI-1’ in 1989, and was highly appreciated by the officials of the Ministry of Defence, Government of India. With more than three decades of a strong, customer-focused approach and a zeal for quality has enabled the Company, to manufacture various types of cables used in diverse fields of power distribution, control, electronics and communication systems. Saraswati Cables has been supplying Power Cables to various Elegizigity Bos projects and utilities for use in their distribution networks, substatt@ communication ds, ONGC, NHPC, P&T, Our portfolio includes the following cable types: + Power and Distribution Cables Flexible Copper Control Cables and Signaling Cables : - Screened Cables Appliance Wires and Plugs Telephone Cables Special cables such as fire resistant and fire survival cables meeting IEC 331 or as per customer requirements are also manufactured depending upon governing specifi Quality Control: (CABLE MANUFACTURING & QUALITY CONTROL Insulation Extrusion In the manufacture of cables, consistent intelligent efforts are incorporated to achieve quality. For quality end products, control starts from proper design of the product. AUl raw materials are selected carefully and only materials of high quality are used in production. Having done this, stage wise inspection is done fo ensure conformity with the requirements of relevant Indian Standards where these apply. Stage Wise Inspection of Wire Process: => Wire diameter! Surface/Shape Thickness of Sheath Diameter over Sheath Tightness of Sheath Eccentricity Embossing & Printing, Laying Up: = Diameter over laid up cores = (Circularity => Sequence of Cores Tests Conduc Rowtiag © Acceptance Tests: Conductor Resistance Test” * —Tetsile Test (Al Conductor) ing Test (Al Conductor) TypeTests: © Tensile Tes (a + Wrapping + Annealing Test (Cu Conch jn Resistance Test © Conductor Resistance Test Ra i Testson Insulation & © Test for thickness of Insulation & oat sheath Physical Test for Insulation & outer Sheath Is 1554.1 (Sq CABLE RANGE AT A GLANCE Type of Cable Application Options Cross Sectional View PVC Power cables for LIK for Electrical substations as por 18:1554-(Part 1) Sizes: Single Core 10-630 sq, mm ‘multi core 6-630 sq. mm ‘Cables for supply to residential, ‘commercial & industrial units (Conductor—Stranded/Solid, Cireu- lar ‘Shaped Aluminium / Copper Insulation - PVC / HR PVC Inner Sheath - PVC / HR PVC FRLS | PVC Unarmoured / Armoured - GS. Round Wire! Flat Strip or Alumi- ‘num Wire/ Flat Strip ‘Outer Sheath - PVC/ HR PVC! ERLS PVC “Annealed electrolytic copper conductor, PVC insulated, PVC sheathed 650/ 1100 grade as per IS: 1554.( Ptl) Sizes 1.5 /2.5 sq, mm upto 61 core 46,10 Sq, mm upto 19 core Copper control cables for power switeh yard control / relay ‘equipment Conductor - Solid'Stranded, Plain / Tinned Insulation - PVC/HR PVC Inner sheath - PVC/HR PVC! FRLS/ZHFR Unarmoured / Armoured - GS. Round wire / fat stip ‘Outer sheath - PVC/HR PVC! FRLS/Zero Halogen Bright annealed EC Grade cop- per, PVC insulated & PVC sheathed of 750V grade as per IS: 694:2010 Sizes:3 core- 1.5 t0 0mm? Flat cables for Submersible ‘pumps & motors ‘Conductor: Copperas per IS 8130 Insulation - PVC / HR PVC Sheathing - PVC / HR PVCs PVC insulated & PVC sheathed Aluminium conductor Twin fla conforming to IS {694 :2010 Voltage rating up to 750 Sizes ‘Two core Sizes up to 50mm? Fixed wiring eable primarily for installa- tions from Electric Poles to Electric Me- ters of Commercial Units ‘Conductor-Aluminium conforming to IS 8130 Insulation— PVC ‘Sheath—PVC Color options: Blue’ Black as per request, ‘Multi strand, flexible, bright an- nealed electrolytic copper condue- tor, PVC insulated & sheathed up to 750V as per 18:694:2010 Sizes : single, two, three or four core upto 19 cores, from Imm —25 mn Flexible cords & cables for appliances, machine tools & equipment wiring ‘Conductor: Copper as per IS 8130 Insulation - PVC / HR PVC / FRLS/ Zero Halogen ‘Unsheathed /Sheathed - PVC / HR PVCs FRLS / Zero Halogen ‘Malti strand flexible, up t 750V) sgrade PVC Cables as per IS: (694:2010 Sizes ‘Single core 0.75 - 630 sq, Wiring cables for electrical industry Conductor - Bright annealed Copper as per IS 81.30 Insulation - PVC/ HR PVC/ FRLS PVC /Zero Halogen PVCITPE Flexible Cables up to 750W grade as per 18:694:2010 ‘Sizes :1.0 up to 240 sq. mm Sin- gle / Multi Core Energy Cables for Power Supply To Telephone Exchanges /UPS/ Battery Backup Equipments for High Current Low Voltage, [Conductor - Stranded / Solid bright annealed Copper as Per IS 8130, Insulation - PVC / HR PVC FRLS/ Zero Halogen saswatig, a SOME OF OUR DISTINGUISHED CLIENTELE DEFENCE RESEARCH HIMACHAL PRADESH STATE PuR ADEs & DEVELOPMENT MANAGEMENT SRGARIGATION| ELECTRICITY BOARD, BOARD . as ZA [Debartment of Telecom, SIVN Govt. of India Sat Jal Vij Nigam Lid DEPARTMENT OF TELECOM Hlectiity Board SATLUJ JAL VIDYUT Punjab Stat ELeCTRIGIY HOARD NIGAM LTD poy THOC NDIA LIMITED : Gi me Gj 22 Tet & °C TEHRI HYDRO om DEVELOPMENT MAHARASHTRA STATE GUJARAT ELECTRICITY CORPORATION ELECTRICITY BOARD BOARD me (ad) aa] AMaharatna Company orl NATHPA JHAKRI HYDRO. POWER STATION ota ELECTRIC POWER NATIONAL THERMAL CORPORATION POWER Industrial U: Saraswati Cables & Allied Industries Pvt. Ltd. 6-B Mehatpur Industrial Area, Mehatpur,Distt ‘Una,Himachal Pradesh, India, 174315 Contact Nos: Varun Thakur +91-9736997997 Kailash K Katwal 09418256031 Cras) Surinder Thakur 09418585700 Office +91-1975-232840 Email: sales.scai@ gmail.com ‘query@saraswaticables.in Website: saraswaticables.in

You might also like