You are on page 1of 104

Purlin & Girt Design Manual

Type C Eaves
Gutter

230 & 260 Fascia

3000 Pan
Head Bolts

Wall
Cladding

FINISH ON TOP WITH FIELDERS


1.15

Contents

PURLIN & GIRT DESIGN MANUAL


1.0 Introduction 8.0 Miscellaneous
1.1 Foreword................................................... 1 8.1 Design Services.......................................... 23
1.2 Company Profile....................................... 1 8.2 Ordering / Pricing...................................... 23
1.3 Scope of Manual...................................... 1 8.3 Availability.................................................. 23
1.4 Guarantees & Warranties.......................... 2 8.4 Storage...................................................... 23
1.5 Disclaimer................................................. 2 8.5 Roofing Profiles.......................................... 23
1.6 Fielders Services........................................ 2 8.5 Product Selection Guide............................. 24

2.0 General Product Data 9.0 References........................................................ 25


2.1 Sections..................................................... 3
2.2 Tolerances................................................. 3 10.0 Index of Purlin Design Tables........................... 27
2.3 Materials................................................... 4 10.1 Single Span 75LC ................................... 28
2.4 Lapping Requirements............................... 4 10.2 Single Span 100LC/100Z ....................... 30
2.5 Bolts.......................................................... 4 10.3 Single Span 100FC ................................. 32
2.6 Standard Punching.................................... 4 10.4 Single Span 150LC/150Z ....................... 34
2.7 Non-Standard Punching............................ 4 10.5 Single Span 200LC/200Z ....................... 36
10.6 Single Span 250LC/250Z ....................... 38
3.0 Section Properties and Dimensions 10.7 Single Span 300LC ................................. 39
3.1 C Sections................................................. 5 10.8 Single Span 350LC ................................. 40
3.2 Z Sections.................................................. 6 10.9 Single Span 400LC ............................... 41
3.3 FC Sections............................................... 7
10.10 Double Continuous Spans 75LC ......... 42
4.0 Fascia Purlins 10.11 Double Continuous Spans 100LC/100Z 44
4.1 Fascia Options.......................................... 9 10.12 Double Continuous Spans 100FC ....... 46
4.2 Standard Fixing Detail............................... 9 10.13 Double Continuous Spans 150LC/150Z 48
4.3 Section Properties...................................... 10 10.14 Double Continuous Spans 200LC/200Z 50
4.4 Loads........................................................ 10 10.15 Double Continuous Spans 250LC/250Z 52
10.16 Double Continuous Spans 300LC ....... 53
5 .0 Bridging 10.17 Double Continuous Spans 350LC ....... 54
5.0 Rows of Bridging....................................... 11 10.18 Double Continuous Spans 400LC ....... 55
5.1 IB Series Intermediate Bridging for
Custom Punched Purlin & Girt 10.19 Double Lapped Span 100Z ................. 56
Systems..................................................... 12 10.20 Double Lapped Span 150Z ................. 58
5.2 FB Series Fascia Bridging for 10.21 Double Lapped Span 200Z ................. 60
Custom Punched Purlin & Girt 10.22 Double Lapped Span 250Z ................. 62
Systems.................................................... 14
5.3 SB Series Support Bridging for 10.23 Three Continuous Spans 75LC ............ 64
Custom Punched Purlin & Girt 10.24 Three Continuous Spans 100LC/100Z 66
Systems.................................................... 15 10.25 Three Continuous Spans 100FC .......... 68
5.4 RB Series Ridge Bridging for 10.26 Three Continuous Spans 150LC/150Z 70
Custom Punched Purlin & Girt 10.27 Three Continuous Spans 200LC/200Z 71
Systems...................................................... 16 10.28 Three Continuous Spans 250LC/250Z 72
10.29 Three Continuous Spans 300LC .......... 73
6.0 Accessories 10.30 Three Continuous Spans 350LC........... 74
6.1 Cleat Dimensions and Details................... 17 10.31 Three Continuous Spans 400LC .......... 75
6.2 Standard Brackets and Cleats for
Multi Hole Fastspan Purlins Only................ 19 10.32 Three Lapped Spans 100Z .................. 76
10.33 Three Lapped Spans 150Z .................. 78
7.0 Design Capacity Tables 10.34 Three Lapped Spans 200Z .................. 80
7.1 Assumptions.............................................. 21 10.35 Three Lapped Spans 250Z .................. 82
7.2 Loads........................................................ 21
7.3 Notes to Capacity Tables........................... 21 10.36 Four Lapped Spans 100Z .................... 84
10.37 Four Lapped Spans 150Z .................... 86
10.38 Four Lapped Spans 200Z .................... 88
10.39 Four Lapped Spans 250Z .................... 90
10.40 Cantilevers .......................................... 92

www.fielders.com.au i
FINISH ON TOP WITH FIELDERS
PURLIN & GIRT DESIGN MANUAL

This page intentionally blank

ii www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15
1.0

Introduction

PURLIN & GIRT DESIGN MANUAL


1.1 Foreword 1.2 Company Profile

Specifying Fielders - Purlin and Girt Design Manual Fielders have been synonymous with quality and
provides detailed product specification and installation strength for over 100 years in an industry where
information as well as a range of useful design data. success is reliant on satisfaction. Initially providing
We are sure you will find this Design Manual of great roofing materials, the company has now extended its
value when using Fielders vast range of purlin and girt product range and reach across Australia to include
products. purlins, door frames, carports, verandahs, fencing,
sheds and flooring. This ensures comprehensive
We look forward to receiving your feedback as you use product offerings and support for all aspects of
this publication. It is with this valued feedback that building construction. Utilising our progressive culture,
Fielders responds to the needs of our clients by specialised resources and market leadership position,
releasing new and improved products and Fielders is famous for our avant-garde approach to
information, such as our new Specifying Fielders - manufacturing and installation. Indeed we are the
Roofing & Walling and Specifying Fielders - only company to have introduced 7 Mobile Roofing
KingFlor Manuals. Your contribution will assist in the Mills, 3 concealed fix roofing profiles and 4 KingFlor
evolution of the Specifying Fielders - Purlin and Girt formwork systems in the past 5 years.
Design Manual.
Being at the forefront of international roofing
In the meantime, we are confident that our Manual will standards, we have attracted the loyalty of many
ensure you always .. architects, engineers, roofers, formworkers and
builders who have experienced the benefits of reduced
"Finish On Top With Fielders". logistical, labour and time expenditures. With these
and many other new developments, Fielders will
continuously strive for growth through superior
products, convenience, quality and service. With
Fielders, you will always "Finish On Top".

1.3 Scope of Design Manual


This Purlin and Girt Design Manual is intended to aid
in the design and installation of Fielders purlin and girt
John Easling
products as well as the associated bridging, fasteners
Managing Director
and accessories. This Design Manual serves as a
reference document and assists all personnel
associated with the specification and construction of
purlins and girts to specify Fielders products. These
personnel typically include Architects and Engineers as
well as Contractors and Builders on site. By following
the guidelines in this Design Manual, a cost effective
and efficient purlin or girt design can be achieved.

The data and information presented in this document


deals specifically with the full range of products
available from Fielders and must not be used for
competitors' products.

www.fielders.com.au 1
FINISH ON TOP WITH FIELDERS
1.4
PURLIN & GIRT DESIGN MANUAL

1.4 Guarantees & Warranties In using Fielders purlin products, the user must take
into account the various factors that may influence the
BlueScope Steel offers a warranty of 10 years from the suitability of its application for a particular project.
date of installation against perforation by natural Some of these factors may include, but are not limited
degradation, when used within the building envelope to, the overall building structure, structural type,
(not exposed to the external environment). stability and layout, loads (dead, live, wind,
earthquake, accidental damage and impact), fire
It is applicable to light industrial/commercial requirements, environmental factors (including
applications located greater than 1km from a marine corrosive environments), and other detailing
or heavy industrial environment only and applies to requirements including end bearing and supports, as
GALVASPAN Steel Z350 and Z450 products when well as the effect of penetrations and non-rectangular
used in purlin applications: geometry.

Warranty requests are evaluated on a case-by-case Fielders are not responsible for the manner in which
basis. BlueScope Steel reserves the right to determine purlins and associated products represented in this
the warranty period given. Design Manual are used in projects, and accordingly,
any building certification pertaining to individual
All BlueScope Steel warranties are subject to terms and projects must be obtained from the Architect and
conditions, which are available from Fielders or from Structural Engineer responsible for the project.
BlueScope Steel.
If the need arises to use products described within this
Design Manual outside the guidelines within this or
1.5 Disclaimer other current technical literature or if any doubt exists
over the interpretation of the use of the products, the
Care has been taken to ensure that the information designer should refer to Fielder's technical
presented herein is accurate, however Fielders representatives for project specific comment and
does not accept responsibility for errors due to assistance prior to work commencing.
misinterpretation by the user. The Design Manual,
associated programs, data files and
documentation are the property of Fielders.
1.6 Fielders Services
Reproduction of any kind, in whole or in part in any
form, without prior written consent is strictly For advice regarding the following items, or any other
prohibited. queries relating to the information contained in this
brochure please contact Fielders.
Standard Warranty imposed by statute law applies
only, with all other conditions, warranties, guarantees The BlueScope Steel corrosion warranty, Fielders
and representations on the part of Fielders expressly product performance warranty.
excluded. Fielders liability pursuant to guarantees are Advice on improving the life expectancy of the
limited to the re-supply of material and specifically profiles.
excludes any claim for consequential direct or indirect Access to design engineers to assist in the
losses. application of the Fielders product.
Design service for large projects including
It is recommended that you obtain qualified expert software analysis.
advice when seeking confirmation of product
application. This Design Manual has been produced
for use by practising Architects and Engineers as a
design aid. The responsibility for the use of the data
lies entirely with the Architect or Engineer, Contractor
or Builder.

2 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
2.0

PURLIN & GIRT DESIGN MANUAL


2.0 General Product Data 2.2 Tolerances
The following tolerances apply to Z and LC sections:
2.1 Sections
Profile Tolerances:
All Fielders Zed (Z) and Cee (LC) sections are rolled to Depth: 2mm
length. LC sections may be used in single spans and Flange width: 2mm
unlapped continuous spans. Z sections may be used Overall length: 2mm for LC sections and 6mm for
over single spans, unlapped continuous, and lapped Z sections.
continuous spans. Hole centres: 1.5mm
Camber: Up to 1 in 500 depending on length.
The following table lists all the purlin and girt sections (Camber is the variation from straightness in the plane
within the Fielders range; of the web.)
Bow: Up to 1 in 300 depending on length. (Bow is the
Table 2.1 variation from straightness in a plane perpendicular to
the web.)
FC sections
Construction Tolerances:
Z sections LC sections (only available in Vic)
Fielders recommend the following construction
tolerances as a good practice guide;
100Z10 75LC10 100FC10
100Z12 75LC12 100FC12
Table 2.2
100Z15 75LC15 100FC15
100Z19 100LC10 100FC19
100Z24 100LC12 Element Tolerance
150Z12 100LC15
150Z15 100LC19 Purlin Levels +S/180 or 10mm
150Z19 100LC24 -S/360 or 5mm (1)
150Z24 150LC12 Purlin Slope 1
200Z15 150LC15 Clip Spacing 2mm (2)
200Z19 150LC19 Clip Alignment to Rib 2 (2)
200Z24 150LC24
250Z19 200LC15
250Z24 200LC19 Note:
200LC24
250LC19 (1) Use the lesser value. S is the purlin spacing.
250LC24 (2) Clips are use for concealed fixed roofing profiles
300LC24 only.
300LC30
350LC30
400LC30

The sections are typically referenced as follows;

e.g. 100Z10
1.0mm gauge

Z Section
100mm deep

www.fielders.com.au 3
2.3
PURLIN & GIRT DESIGN MANUAL

2.3 Materials 2.6 Standard Punching

All purlins are rolled using BlueScope Steel 22 x 18mm slotted holes will be punched when using
GALVASPAN high tensile steel. This product has a standard grid line centres of 40, 60, 110, and 160.
standard galvanized coating of Z350 (350 grams of Flange punching is also available.
zinc per m2) and is typically used in non-aggressive
areas. For severe and aggressive environments where 2.7 Non-Standard Punching
a build-up of airborne corrosive contaminants can
affect the coating, Z450 is recommended (450 grams Non-standard punching and non-standard round
of zinc per m2). The following table lists the Steel holes are available and are subject to negotiation with
Grade for each steel gauge; Fielders.

Table 2.3 Fielders detailing sheets are available as a service to


the industry and may be obtained by contacting your
Gauge Steel Grade (MPa) local Fielders office.

1.0mm 550
1.2mm 500
1.5mm 450
1.9mm 450
2.4mm 450
3.0mm 450

2.4 Lapping requirements


In order to ensure continuity in lapped span systems,
lap lengths should be of an adequate distance and be
substantially connected. For lapped purlin systems the
length of the lapped region over each support is 15%
of the span (ie 7.5% of the span on each side of the
support). In order to achieve satisfactory connectivity at
the lap each end of the lap must have one bolt through
the flanges farthest from the cladding and another bolt
through the webs at the end of the webs closest to the
cladding. For further advice on this bolting
arrangement, contact a Fielders technical
representative.

2.5 Bolts
Fielders supply grade 4.6 bolts. It has been assumed
in the preparation of the capacity tables within this
Design Manual that the purlins are connected through
the web of the purlin to cleats. Purlins of depths less
than 300mm require two M12 bolts and purlins of
depth 300mm or greater require two M16 bolts.
Typically purlin span configurations require grade 4.6
bolts, however numbers shown in bold italics in the
capacity tables in section 10.0 require grade 8.8 bolts.

4 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15
3.0

PURLIN & GIRT DESIGN MANUAL


3.0 Section Properties and
Dimensions
The following are the Section Properties for Fielders
Purlin and Girt products.

3.1 C Sections
Table 3.1
Cat No. A B D t CY Area Mass Ix Iy Zx Zy rx ry J Iw
mm mm mm mm mm mm 2
kg/m 10 mm
6 4
10 mm
6 4
10 mm
3 3
10 mm
3 3
mm mm mm 4
10 mm4
6

75LC10 76 44 13 .95 15.9 167.9 1.32 0.159 0.046 4.184 1.639 30.8 16.6 50.52 62.18

75LC12 76 44 13 1.20 15.9 210.7 1.65 0.198 0.057 5.211 2.025 30.7 16.4 101.13 73.37

75LC15 76 45 14 1.50 16.6 267.2 2.10 0.249 0.076 6.687 2.734 30.5 16.8 200.40 99.14

100LC10* 102 44 15 .95 14.5 196.4 1.54 0.319 0.054 6.255 1.845 40.3 16.6 59.10 124.20

100LC12* 102 44 15 1.20 14.5 246.7 1.94 0.398 0.067 7.804 2.283 40.2 16.5 118.41 151.67

100LC15* 102 45 15 1.50 14.9 309.2 2.43 0.498 0.087 9.908 2.945 40.1 16.7 231.9 192.04

100LC19* 102 45 15 1.90 14.9 388.0 3.05 0.618 0.106 12.350 3.646 39.9 16.6 466.85 230.37

100LC24* 102 46 15 2.40 15.3 489.0 3.84 0.744 0.136 15.540 4.610 39.8 16.7 938.92 286.63

150LC12 152 64 18 1.20 19.9 361.9 2.84 1.320 0.204 17.500 4.700 60.4 23.8 173.72 969.48

150LC15 152 64 18 1.50 19.9 450.2 3.53 1.633 0.251 21.700 5.794 60.2 23.6 337.65 1178.44

150LC19 152 64 18 1.90 19.9 566.6 4.45 2.041 0.311 27.190 7.205 60.0 23.4 681.71 1438.77

150LC24 152 64 18 2.40 19.9 709.8 5.57 2.535 0.318 33.890 8.891 59.8 23.2 1362.9 1735.08

200LC15 203 74 19 1.50 21.0 559.7 4.39 3.539 0.400 35.120 7.654 79.5 26.7 419.77 3230.95

200LC19 203 75 21 1.90 21.9 716.6 5.63 4.523 0.543 44.980 10.240 79.4 27.3 862.38 4359.58

200LC24 203 76 21 2.40 22.3 904.2 7.10 5.685 0.680 56.690 12.950 79.3 27.4 1736.00 5475.10

250LC19 254 71 21 1.90 18.1 798.4 6.27 7.424 0.500 58.900 9.622 96.4 25.0 96.69 6311.39

250LC24 254 71 21 2.40 18.1 1002.6 7.87 9.266 .0616 73.650 11.910 96.1 24.8 1925.00 7695.88

300LC24 300 96 27 2.40 26.1 1261.8 10.09 16.940 1.500 113.800 21.840 115.9 34.5 2422.7 26357.47

300LC30 300 96 31 3.00 27.2 1592.5 12.76 21.290 1.944 143.300 28.860 115.6 34.9 4790.00 34816.67

350LC 350 125 30 3.00 33.2 1910.0 14.99 35.790 3.811 206.300 42.920 136.90 44.7 5729.00 90010.00

400LC 400 96 34 3.00 22.3 1910.0 14.99 42.760 2.198 215.400 31.070 149.60 33.9 5729.00 70130.00

Y
B * Available in South Australia
D (Victorian 100 FC Sections shown page 7)

A
X X

D
CY
C
Y

www.fielders.com.au 5
FINISH ON TOP WITH FIELDERS
3.2
PURLIN & GIRT DESIGN MANUAL

3.2 Z Sections

Table 3.2
Cat No. A B C D t Area Mass Ix Iy Zx Zy rx ry J Iw
mm mm mm mm mm mm2 kg/m 106mm4 106mm4 103mm3 103mm3 mm mm mm4 106mm4

100Z10 102 49 42 14 0.95 197.4 1.55 0.323 0.098 6.132 2.111 40.5 22.3 59.38 154.61

100Z12 102 49 42 14 1.2 247.9 1.95 0.403 0.122 7.651 2.617 40.3 22.2 118.98 190.53

100Z15 102 49 42 15 1.5 310.7 2.44 0.501 0.154 9.501 3.324 40.1 22.3 233.00 241.93

100Z19 102 49 42 15 1.9 389.8 3.06 0.622 0.189 11.797 4.085 39.9 22.0 469.08 294.54

100Z24 102 50 43 15 2.4 491.4 3.86 0.778 0.242 14.763 5.157 39.8 22.2 943.42 374.10

150Z12 152 65 59 19 1.2 359.5 2.82 1.299 0.322 16.762 5.123 60.1 29.9 172.55 1200.22

150Z15 152 65 59 19 1.5 447.2 3.51 1.608 0.395 20.741 6.300 60.0 29.7 335.37 1469.37

150Z19 152 65 60 19 1.9 564.6 4.43 2.020 0.498 26.147 7.936 59.8 29.7 679.42 1882.13

150Z24 152 65 60 20 2.4 712.2 5.59 2.524 0.627 32.671 10.032 59.5 29.7 1367.36 2371.14

200Z15 203 79 73 17 1.5 559.7 4.39 3.556 0.643 34.483 8.374 79.7 33.9 419.75 4322.87

200Z19 203 79 73 20 1.9 716.6 5.63 4.535 0.860 43.981 11.227 79.5 34.6 862.33 5807.85

200Z24 203 79 74 21 2.4 906.6 7.12 5.709 1.103 55.513 14.397 79.4 34.9 1740.61 7563.49

250Z19 254 79 74 18 1.9 808.0 6.50 7.62 0.833 59.300 10.800 97.1 32.1 972.00 9480.00

250Z24 254 79 73 21 2.4 1030.0 8.16 9.64 1.080 74.900 14.200 96.9 32.5 1970.00 12400.00

V Y
B

D
U

X < X

t A
U

Y V

6 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15
3.3

PURLIN & GIRT DESIGN MANUAL


3.3 FC Sections (Victoria Only)
Table 3.3

Cat No. A B D t CY Area Mass Ix Iy Zx Zy rx ry J Iw


mm mm mm mm mm mm2 kg/m 106mm4 106mm4 103mm3 103mm3 mm mm mm4 106mm4
100FC10 102 51 12.5 1.0 16.1 216 1.78 0.36 0.0755 7.130 2.190 41.1 18.7 71.90 160.00
100FC12 102 51 12.5 1.2 16.0 258 2.10 0.4320 0.892 8.480 2.590 41.0 18.6 124.00 188.00
100FC15 102 51 13.5 1.5 16.1 323 2.62 0.5370 0.112 10.50 3.290 40.8 18.7 242.00 241.00
100FC19 102 51 14.5 1.9 16.2 409 3.29 0.673 0.142 13.20 4.210 40.6 18.7 492.00 311.00

Note:
The 100FC range is available in Victoria in lieu of the
100LC range on page 5.

B
D

X X

D
CY
C
Y

www.fielders.com.au 7
FINISH ON TOP WITH FIELDERS
PURLIN & GIRT DESIGN MANUAL

This page intentionally blank

8 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15
4.0

PURLIN & GIRT DESIGN MANUAL


4.0 Fascia Purlins

4.1 Fascia Options

The following fascia sections are available from


Fielders and have been designed to allow the following
four options.

Each option has been designed to be used with the


standard punched purlin and girt system and the
fastspan purlin and girt system.

125mm 125mm 140mm 140mm


17mm 17mm 20mm 20mm
50mm

50mm

85-90 85-90

65mm
85-90 85-90
65mm

THIS ANGLE THIS ANGLE THIS ANGLE


VARIES VARIES THIS ANGLE
VARIES VARIES
257mm

257mm

Type B Type C

230mm
110mm
Type D Type E
160mm

160mm

230mm
110mm

90 85 85
28mm 90 55mm

56mm 28mm 55mm


40mm
56mm 40mm

4.2 Standard Fixing Details

Roof
Roof
Type B Eaves Sheeting Type C Eaves Sheeting
Gutter
Gutter

Method of Method of fixing


fixing wall 230 & 260 Fascia wall cladding to 230 & 260 Fascia

cladding to 3000 Pan external face of 3000 Pan


Head Bolts fascia flange Head Bolts
internal face of
fascia flange
Wall
Wall Cladding
Cladding

www.fielders.com.au 9
FINISH ON TOP WITH FIELDERS
4.3
PURLIN & GIRT DESIGN MANUAL

4.3 Section Properties

Table 4.1
Fascia Purlin Section Properties
Second Moment of Area Torsion Warping Monosymmetric Shear Centre Centroid
Fascia Purlin Area (106mm4) Constant Constant Constant (mm) (mm) (mm)
Type (mm2) lx ly lx ly J (mm4) lw (109mm6) x y xo yo xc yc (deg)

Type C 757.7 8.124 1.151 7.91 9.88 646.6 5.46 - 134.52 296.19 - 66.31 60.69 28.51 110.8 - 9.689
Type E 760.3 7.537 1.483 7.4 1.19 648.8 2.56 - 148.8 296.91 - 72.97 66.63 33.79 96.87 - 13.457

4.4 Loads
The load capacities provided in the following table are
allowable loads only and not limit state loads. These
tables are only to be used by qualified experts who are
able to factor the loads accordingly to limit state for
design purposes.

For further assistance, contact a Fielders technical


representative.

Table 4.2
Allowable loads for Fascia Purlin Type C (kN/m)
SPAN (mm) 6000 6600 7200 7800 8400 9000 9600 10000
One Bridge 1.69 1.22 0.91 0.69 0.53 0.42 0.33 0.27
Two Bridge 2.30 1.84 1.47 1.19 0.97 0.79 0.64 0.52
Fully Braced 2.30 1.90 1.60 1.36 1.18 1.02 0.90 0.80
Defl. (L150) 3.75 2.82 2.17 1.71 1.37 1.11 0.92 0.76

Table 4.3
Allowable loads for Fascia Purlin Type E (kN/m)
SPAN (mm) 6000 6600 7200 7800 8400 9000 9600 10000
One Bridge 1.35 0.97 0.72 0.54 0.42 0.33 0.26 0.21
Two Bridge 2.18 1.69 1.32 1.03 0.80 0.63 0.51 0.41
Fully Braced 2.36 1.95 1.64 1.40 1.21 1.05 0.92 0.82
Defl. (L/150) 3.51 2.63 2.03 1.60 1.28 1.04 0.86 0.71

Notes: 4. Load capacities for fully braced case assume roof sheeting attached to top
1. Yield stress is 300MPa. flange and wall sheeting attached to bottom lip.
2. Top flange is assumed to be at 90 to web for load capacity calculations. 5. Standard M12 Purlin bolts to be used.
3. Load capacities for one and two bridging cases assume roof sheeting 6. Loads are allowable only.
attached to top flange.

10 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15
5.0

PURLIN & GIRT DESIGN MANUAL


5.0 Bridging
The purlin capacity tables in this Design Manual have
been prepared in consideration of the following
bridging locations along the length of the purlin.

Table 5.1

Rows of Bridging 1 2 3

Simple Spans 50% + 50 % 35% + 30% + 35% 28% + 22% + 22% + 28%
Interior Spans 50% + 50 % 37% + 26% + 37% 28% + 22% + 22% + 28%
End Spans (Unlapped) 45% + 55 % 33% + 28% + 39% 27% + 21% + 25% + 27%
End Spans (Lapped) 40% + 60 % 34% + 26% + 40% 27% + 21% + 25% + 27%

The Fastlock Bridging System for custom punched About Bridging


purlins and girts consists the following range of
bridging series; The bridging network should be locked into position
prior to the commencement of fixing roof and wall
IB series Intermediate Bridging cladding. Failure to meet the requirement may result in
FB series Fascia Bridging the permanent twisting of the unrestrained web
SB series Support Bridging sections.
RB series Ridge Bridging
GH series Girt Hanger Bridging Twisted or distorted webs, in addition to being visually
unacceptable, may greatly reduce the load capacity of
the total system.

Consult the capacity tables for design details.


RB
IB
FB

GH

IB

SB

www.fielders.com.au 11
FINISH ON TOP WITH FIELDERS
5.1
PURLIN & GIRT DESIGN MANUAL

5.1 IB Series Intermediate Erection


IB bridging is required between each spacing of purlins
Bridging for Custom Punched and girts. Always keep the hook and bracket in the
Purlin & Girt Systems downward position. Working up the roof slope or from
floor level insert the hook through the locator of the
IB Bridging preceding bridge, repeat until all units are completed.
The IB bridge is identified by the distinctive hook & The hook is normally entered at about 15 20 angle
locator brackets. Units are produced with both brackets to the purlin or girt web.
press fixed to a channel spacer. When detailing length
requirements, it is only necessary to nominate the purlin When erecting IB bridging to wall girts ensure that SB
or girt spacing minus 3mm as shown in Diagram B. support bridging or GH bridging have been installed.
Capacity Tables should be consulted for bridging
configurations. Fastlok IB bridging is available in the
100IB, 150 IB and 200 IB series only.

DETAILING THE IB SERIES


NOMINATE CAT NO. FOR USE WITH
IB Bridge 100IB 100Z 100LC
Catalogue No. 150IB 150Z 150LC
200IB 200Z 200LC/250Z 250LC

IB Bridge Nominate purlin or girt spacing minus 3mm.


Length No other dimension required (See Dia. B)
100TAB 100Z 100LC
Fastlok 150TAB 150Z 150LC
Bracket 200TAB 200Z 200LC/250Z 250LC

Fixed End 100FEB 100Z 100LC


Bracket 150FEB 150Z 150LC
200FEB 200Z 200LC/250Z 250LC

Pitch of Roof When over 20 only

Note: If practical, observe standard cleat spacing.

Note:
It is important to distribute temporary working loads
while erecting bridging to purlins. A suitable plank laid
over a minimum of 4 or 5 purlins is adequate. Ensure
that unbroken roof sheeting packs are off loaded over Diagram A
structural supports, not mid span.

IB bridging is available to suit all spacing requirements.

12 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15
5.1

PURLIN & GIRT DESIGN MANUAL


A
Purlin spacing 3mm

Diagram B

www.fielders.com.au 13
FINISH ON TOP WITH FIELDERS
5.2
PURLIN & GIRT DESIGN MANUAL

5.2 FB Series Fascia Bridging for Erection


FB bridging should be erected before IB or RB bridging
Custom Punched Purlin is commenced. The unit is bolted to the fascia, while
& Girt Systems the opposite end bracket provides the locator through
which the Fastlok hook is engaged. When the total
bridge network has been installed the fascia channel is
FB bridging is produced with fully adjustable telescopic
aligned and FB component bolts tightened. When
channels and slotted end brackets. This enables
opposite hand FB bridging is required, remove TB
accurate adjustment when aligning fascias and other
bracket and rotate.
termination members. When detailing FB bridging,
nominate the spacing between the end purlin and
The FB bridge, when used at the head of a skillion
fascia while channels of appropriate combined length
frame must be bolted to the adjacent IB bridge, (see
will be supplied. On occasions, only one channel may
inset).
be required.

DETAILING THE FB SERIES


NOMINATE CAT NO. FOR USE WITH
A
FB Bridge 100FB 100Z 100LC
Catalogue No. 150FB 150Z 150LC
200FB 200Z 200LC/250Z 250LC

FB Bridge Nominate spacing between end purlin and fascia purlin.


Length minus 3mm

Terminating 150TB 150LC


Bracket 200TB 200LC/230 Fascia
250TB 250LC/260 Fascia
Pitch of Roof When over 20 only

Note: FB Bridge is supplied shop bolted.

Recommended
fascia section

260 Folded Fascia


or 230 Folded Fascia

Diagram A

14 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15
5.3

PURLIN & GIRT DESIGN MANUAL


5.3 SB Series Support Bridging for
Custom Punched Purlin & Girt
Systems

SB Series
Designed to support the first wall girt at floor level, the
SB bridge is also useful when the accurate length of
fixed end bridging is difficult to calculate. On
completion of the concrete floors the SB bridging
should be inserted and bolted to the slab (concrete
A
fixings by others).

This ensures that wall girts are held straight before the
IB bridging is commenced. Unsupported girts result in
unsatisfactory sagging of cladding and glazing.
Diagram C
If unable to use SB bridging (eg. no floor slab), girts
must be supported from fascia bridging using GH
Bridging (see diagram C).

150mm min. can


NOMINATE CAT NO. FOR USE WITH reduce to 75mm
by deleting A
SB Bridge 100SB 100mm girts channel (see
Diagram A inset)
Cat. No. 150SB 150mm girts
200SB 200mm/250mm girts
SB Length Nominate measurement A only
Diagram B

NOMINATE CAT NO. FOR USE WITH


GH 100GH 100mm girts
Bridge 150GH 150mm girts
200GH 200mm/250mm girts
GH Length Nominate measurement A only

Note: If measurement A less than 150mm use BEB end


brackets in combination consult Fielders Technical
Representative for further details.

www.fielders.com.au 15
FINISH ON TOP WITH FIELDERS
5.4
PURLIN & GIRT DESIGN MANUAL

5.4 RB Series Ridge Bridging for DETAILING THE RB SERIES


Custom Punched Purlin & Girt NOMINATE CAT NO. FOR USE WITH
100RB 100Z 100LC
Systems RB Bridge 150RB 150Z 150LC
Cat. No. 200RB 200Z 200LC/250Z 250LC
RB Bridge RB Bridge Nominate measurement A only
The turnbuckle principle enables the RB Bridge to be Length
inserted after the total bridging network has been Pitch of Roof When over 20 only
completed. The unit is shop bolted, but may need
releasing prior to fixing depending on accessibility.
If practical, maintain 150mm as the standard
distance from the centre line of the building frame to
the lower side of the top purlin cleat, (see diagram B).
RB bridging however, is available to suit all dimension
A requirements.

Note: RB is supplied shop bolted.

PITCH TABLE
To determine measurement A.
Formula = B + Pitch Table x 2
(Similar for C sections)
Pitch 150mm 200mm
Web Web
1 2.5mm 3.0mm
5 10.0mm 14.0mm
7.5 16.0mm 23.0mm
10 22.0mm 32.0mm
12.5 27.0mm 33.0mm Diagram A
15 32.0mm 45.0mm
20 44.0mm 61.0mm

Refer
Pitch
Table
A
Diagram B

B
Stan
purli dard ridg
n spa e
cing

16 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15
6.0

PURLIN & GIRT DESIGN MANUAL


6.0 Accessories

6.1 Cleat Dimensions and Details

SECTION DIMENSIONS All dimensions in mm. CLEAT DIMENSIONS


Section A B C D t E F G
Z Section Profile
B
Identification mm mm mm mm mm mm mm mm
100Z10 102 49 42 14 1.0 40 112 105
D
100Z12 102 49 42 14 1.2 40 112 105
100Z15 102 49 42 15 1.5 40 112 105
100Z19 102 49 42 15 1.9 40 112 105
100Z24 102 50 43 14 2.4 40 112 105
A t E
150Z12 152 65 59 19 1.2 60 163 156
150Z15 152 65 59 19 1.5 60 163 156
150Z19 152 65 60 19 1.9 60 163 156
150Z24 152 65 60 20 2.4 60 163 156
C D
200Z15 203 79 73 17 1.5 110 213 206
200Z19 203 79 73 20 1.9 110 213 206
200Z24 203 79 74 21 2.4 110 213 206

Section A B C D t E F G
C Section Profile Lipped Identification mm mm mm mm mm mm mm mm
100LC10 102 44 15 1.0 40 112 105
B 100LC12 102 44 15 1.2 40 112 105
D 100LC15 102 45 15 1.5 40 112 105
100LC19 102 45 15 1.9 40 112 105
100LC24 102 46 15 1.5 40 112 105
150LC12 152 64 18 1.2 60 162 156
A E t 150LC15 152 64 18 1.5 60 163 156
150LC19 152 64 18 1.9 60 163 156
150LC24 152 64 18 2.4 60 163 156
200LC15 203 74 19 1.5 110 213 206
D 200LC19 203 75 21 1.9 110 213 206
200LC24 203 76 21 2.4 110 213 206
250LC15 254 71 21 1.5 160 264 257
250LC19 254 71 21 1.9 160 264 257
250LC24 254 71 21 2.4 160 264 257

www.fielders.com.au 17
FINISH ON TOP WITH FIELDERS
6.1
PURLIN & GIRT DESIGN MANUAL

CLEAT DETAILS - Dimensions E, F & G as per table on


page 17.

F
F

E
E

A
E
Standard Fascia Detail
Standard Z Section Detail Standard LC Section Detail

75
130 130
30 70 30 30 70 30
2/16 dia holes
4/16 dia holes 4/18 dia holes
G

Type 1
E

Type 2 Type 3
G
E

E
42/56
42/56

Standard Z section cleat Standard LC section cleat Standard fascia cleat


Non structural lap 2 bolts
structural lap 6 bolts

Note
The cleats depicted above are not supplied by Fielders. These details are provided to assist with co-ordination
between cleats provided by others and the punched bolt holes in the purlins.

18 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15
6.2

PURLIN & GIRT DESIGN MANUAL


6.2 Standard Brackets and Cleats
for Multi Hole Fastspan Purlins
Only

Wherever practical purlin and girt cleats should be


welded to columns and rafters at centres to suit the
standard lengths of Fastlok bridging components.

It has been found economical to use standard Fastlok


cleats for all intermediate purlin and girt spacing
utilizing the adjustable fascia bridging to accomodate
non conforming measurements.

A
A
E
40 D 40

40
C B
17 B
17 C
42

50 D
50

TYPE 1
TYPE 2

CLEAT DIMENSIONS (For multi punched Z section only)


CAT NO. A B C D E Punching Finish Mass
100KC 150 100 60 70 8 50 x 17 BLACK 0.86 kg

150KC 75 156 89 8 50 x 17 MILD 0.67kg

200KC 75 206 140 8 50 x 17 STEEL 0.86 kg

www.fielders.com.au 19
FINISH ON TOP WITH FIELDERS
6.2
PURLIN & GIRT DESIGN MANUAL

The accessories provide the designer with solutions to


a wide range of on site problems normally requiring
purpose made brackets or welded connections.

Used singularly or in combination the accessories will


readily form any of the following:
door framing
window framing
box gutter supports
parapet framing
general support systems for follow up trades

Clamp Plates General Purpose Brackets


A
E

B
A
70

70
D
70
35 C
A B
70 All holes18 x 30
35
B
BUP Series
35 GPBLL Series
GPB Series

ACCESSORY DIMENSIONS
CAT NO. A B C D E Base Metal Thickness (BMT )
100BUP 90 40
150BUP 140 60
200BUP 190 110 3mm
250BUP 240 160
100GPB 90 40
150GPB 140 60
200GPB 190 110 3mm
250GPB 240 160
100GPBLL 66 115 30 60 60
150GPBLL 105 125 30 67 60
200GPBLL 154 136 36 73 110 3mm
250GPBLL 200 136 36 73 160

20 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15
7.0

PURLIN & GIRT DESIGN MANUAL


7.0 Design Capacity Tables 7.3 Notes to Capacity Tables
All spans are in mm.
7.1 Assumptions Linear interpolation of capacities is allowed.
The uniformly distributed load (UDL) for
The information contained within the following deflection in mm of span/150 is the load for the
capacity tables and the associated sectional properties span that results in a value for deflection of
have been determined in accordance with AS/ANZ span/150. It must not be confused with the
4600:1996 Cold-formed steel structures. design capacity of the member.
k is a factor that when multiplied by the design
The design capacity tables have been prepared based load in kN/m results in an approximate value for
on the following assumptions: purlin deflection in mm. Interpolation of the
The loads applied to the purlins act parallel to the k factor between spans is not allowed. The k
Y-axis of the Z or LC section. factor assigned to the first tabulated span greater
The loads are applied uniformly to the top flange than the design span shall be used in all cases.
of the purlin.
The members behave in accordance with the Loading capacities
simple theory of bending. Inward = inward loading capacity - assumes
The roof sheeting is screw fastened to the top the load is acting to force the cladding against
flange of the purlins to provide diaphragm shear the structure, measured in units of kN/m where 0
stiffness but not torsional restraint to the purlins. = no bridging, 1 = 1 row of bridging, 2 = 2
rows of bridging and 3 = 3 rows of bridging
7.2 Loads placed at locations along the span in
accordance with Table 5.1 in Section 5.0.
The loads provided in the capacity tables are uniformly Outward = outward loading capacity -
distributed and interpolation between span assumes the load is acting to force the cladding
configurations is allowed. away from the structure, also measured in units
of kN/m
The determination of loading conditions must be made The tables do not include capacities less than
on a project specific basis and is outside the scope of 0.4 kN/m and where additional bridging
this Design Manual. It is essential that the user of this provides less than 2% additional capacity no
Design Manual have the loading conditions for the value is stated.
design case calculated and verified by a qualified
professional taking into consideration the appropriate Values shown in bold italics indicate the
standards and codes. requirement to adopt grade 8.8 bolts, otherwise
grade 4.6 bolts are assumed.
For project specific cases where point loads are
applied to the purlins, an equivalent uniformly For purlin depths less than 300mm, 2 x M12
distributed load can be determined using Table 7.1 bolts are required and for depths 300mm or
and then selecting the appropriate number from the greater 2 x M16 bolts are required.
design capacity tables.
The capacity tables assume that the FastLock
Bridging system is adopted.

www.fielders.com.au 21
FINISH ON TOP WITH FIELDERS
7.2

w = Equivalent uniformly distributed (kN/m)


P = single point load (kN)
PURLIN & GIRT DESIGN MANUAL

Table 7.1 L = span (mm)


a = largest distance from support (mm)
Symmetrical Equidistant Point Loads b = smallest distance from support (mm)
N = Number of point loads for 6 or more loads over one span.

Loading Condition Conversion Formula

P
Simple
w=2P/L
Single
Load P
Lapped w=2.22P/L

P P
Simple
2 Loads w=2.67P/L
P P
Lapped w=3.16P/L

P P P
Simple w=4P/L
3 Loads P P P
Lapped w=3.78P/L

P P P P
Simple
w=4.8P/L
4 Loads P P P P
Lapped w=5.12P/L

P P P P P
Simple
w=6P/L
5 Loads P P P P P
Lapped w=6.65P/L

P P P P P P
Simple w=1.14NP/L
N (6 or more)
Loads P P P P P P
Lapped w=1.22NP/L

Single Eccentric and Two Symmetrical Point Loads


a b
Loading Condition Conversion Formula
P
Simple
Single w=8abP/L3
Eccentric P
Point Load Lapped w=17.76ab2 P/L4

a b

a b

P P
2 Symmetrical Simple w=8bP/L2
Point Loads
P P
w=9.45b(2L-3b)P/L3
Lapped

a b

22 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15
8.0

PURLIN & GIRT DESIGN MANUAL


8.0 Miscellaneous 8.6 Flooring Profiles
Fielders have an extensive selection of composite steel
8.1 Design Services flooring profiles. More information on our KF70,
KF57, RF55 and CF210 profiles can be obtained
Contact a Fielders technical representative for further via the Specifying Fielders - KingFlor Manual or
assistance with your design or use of these tables. your local Fielders representative.

8.2 Ordering / Pricing


Contact your local Fielders branch for a standard order
form and for any pricing and order enquiries. Details
of branches are located in the front cover.

8.3 Availability
All purlins are rolled to order and are available in
lengths up to 12.0m. Longer lengths maybe available
on request and may occur additional delivery charges.

8.4 Storage
Purlins should not be left in exposed areas for extended
periods of time. They should be stacked neatly and
positioned so that water is not allowed to pond.

8.5 Roofing profiles


Fielders offer a comprehensive range of both pierce
fixed and concealed fixed roofing products. Pierced
fixed roof and wall cladding is traditionally used in the
domestic market, with Fielders offering a 5 year
watertight guarantee. Concealed fixed roofing profiles
eliminate the need for piercing the decks and with
mobile milling the sheets can be rolled to any length
required removing the need for step joints. Fielders
offer a 20 year watertight guarantee for its entire range
of concealed fixed profiles.

For further information on Fielders range of roof and


wall claddings refer to Table 8.1, page 24 of
Specifying Fielders - Roofing & Cladding or your
local Fielders representative.

www.fielders.com.au 23
FINISH ON TOP WITH FIELDERS
8.5
PURLIN & GIRT DESIGN MANUAL

Table 8.1 Product Selection Guide

Max. recommended spacing of Safe load span for Guarantee


supports for normal conditions (mm) carport and verandahs
Roofing and Lineal Minimum
Walling Profiles Metre Width of Depth recomded Roof Span Wall Span
Material CAT CAT
BMT Mass coverage of rib roof pitch Selection 2 3
(mm) (Kg/lm) (mm) (mm) (mm) Single End Internal Single End Internal

KingKlip 0.42 3.3 700 42 1 1600 1700 2100 2100 2100 2400
20 yrs
700 0.48 3.7 700 42 (1 in 60) 2000 2550 3000 2300 2700 2900

Wideklip 0.42 3.3 760 35 2 1100 1300 1800 1500 1900 2500
20 yrs
760 0.48 3.7 760 35 (1 in 30) 1350 1800 2400 1600 2200 2500

Hi-Klip 0.42 3.3 630 66 1 2000 2200 2600 2400 2600 2900
630 20 yrs
0.48 3.7 630 66 (1 in 60) 2400 2700 4000 2400 2700 3600

Single 1500 1500


0.42 2.4 500 40 1 - 1200 1300 - 1500 1500
Multiple 1500 1500
Klipdek
Single 2700 3000
500 0.48 2.7 500 40 (1 in 60) - 1800 2100 - 2500 2400 20 yrs
Multiple 2700 3000
Single 3600 3600
0.60 3.3 500 40 (1 in 60) - 2400 2700 - 2500 2700
Multiple 3600 3600
Single 3600 3600
Snaplok 0.55 2.7 406 48 1 - 1650 1900 - 1800 2300 Multiple 3600 3600 20 yrs
406 0.70 3.5 406 48 (1 in 60) - 2100 2400 - 2200 2900 Single 3600 3600
Multiple 3600 3600

Hi-Rib
0.42 3.3 680 48 1 - 2800 3400 - 3000 4000 Single 3100 3900 5 yrs
680

0.42 3.3 760 16 5 700 900 1200 1200 1350 1800 Span mm
S-Rib 5 yrs
Corrugated 0.48 3.7 760 16 (1 in 12) 700 1200 1600 1500 1800 2400

Curving 0.6 4.7 760 17 5 600 900 1200 1200 1350 1800
5 yrs
Quality (1 in 12)
Corrugated

0.42 3.3 760 28 2 1000 1300 1700 1800 1800 2200


TL-5/M-Clad
0.48 3.7 760 28 (1 in 30) 1500 1700 2300 1950 2050 2800 5 yrs

0.42 3.3 700 24 3 1300 1800 2400 1800 1800 2700


Spanform 5 yrs
0.48 3.7 700 24 (1 in 20) 2000 2200 3000 2600 1900 2800

Walling Only Lineal Metre Width of Depth Maximum recommended spacing of


BMT Mass coverage of rib wall supports for normal conditions
Profiles (mm) (Kg/lm) (mm) (mm) Internal Spans (mm)
S-Rib 0.35 2.75 760 16 1600
Corrugated

TL-5/M-Clad 0.35 2.75 760 28 1600

Lo-Rib 0.42 3.3 817 12 1800

Panelform 0.42 3.3 865 4 600

0.42 3.3 810 6 1200


Mini-Flute 0.48 3.7 810 6 1350
0.60 4.7 810 6 100

250 Panel 0.48 1.0 250 12.5 1200

Weather-
board 0.42 1.85 260 600
Panel

BMT = Base Metal Thickness

24 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15
9.0

PURLIN & GIRT DESIGN MANUAL


9.0 References
AS/NZS 4600:1996 - Cold-formed steel structures.

Load Capacity Tables, Investigation Report No. S1403,


November 2003, University of Sydney Department of
Civil Engineering - Centre for Advanced Structural
Engineering.

www.fielders.com.au 25
FINISH ON TOP WITH FIELDERS
10.0
PURLIN & GIRT DESIGN MANUAL

This page intentionally blank

26 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15
10.0

PURLIN & GIRT DESIGN MANUAL


10.0 Index of Purlin Design Tables
10.1 Single Span 75LC ................................... 28
10.2 Single Span 100LC/100Z ....................... 30
10.3 Single Span 100FC ................................. 32
10.4 Single Span 150LC/150Z ....................... 34
10.5 Single Span 200LC/200Z ....................... 36
10.6 Single Span 250LC/250Z ....................... 38
10.7 Single Span 300LC ................................. 39
10.8 Single Span 350LC ................................. 40
10.9 Single Span 400LC ............................... 41

10.10 Double Continuous Spans 75LC ......... 42


10.11 Double Continuous Spans 100LC/100Z 44
10.12 Double Continuous Spans 100FC ....... 46
10.13 Double Continuous Spans 150LC/150Z 48
10.14 Double Continuous Spans 200LC/200Z 50
10.15 Double Continuous Spans 250LC/250Z 52
10.16 Double Continuous Spans 300LC ....... 53
10.17 Double Continuous Spans 350LC ....... 54
10.18 Double Continuous Spans 400LC ....... 55

10.19 Double Lapped Span 100Z ................. 56


10.20 Double Lapped Span 150Z ................. 58
10.21 Double Lapped Span 200Z ................. 60
10.22 Double Lapped Span 250Z ................. 62

10.23 Three Continuous Spans 75LC ............ 64


10.24 Three Continuous Spans 100LC/100Z 66
10.25 Three Continuous Spans 100FC .......... 68
10.26 Three Continuous Spans 150LC/150Z 70
10.27 Three Continuous Spans 200LC/200Z 71
10.28 Three Continuous Spans 250LC/250Z 72
10.29 Three Continuous Spans 300LC .......... 73
10.30 Three Continuous Spans 350LC........... 74
10.31 Three Continuous Spans 400LC .......... 75

10.32 Three Lapped Spans 100Z .................. 76


10.33 Three Lapped Spans 150Z .................. 78
10.34 Three Lapped Spans 200Z .................. 80
10.35 Three Lapped Spans 250Z .................. 82

10.36 Four Lapped Spans 100Z .................... 84


10.37 Four Lapped Spans 150Z .................... 86
10.38 Four Lapped Spans 200Z .................... 88
10.39 Four Lapped Spans 250Z .................... 90
10.40 Cantilevers .......................................... 92

www.fielders.com.au 27
FINISH ON TOP WITH FIELDERS
10.1

Single Span
PURLIN & GIRT DESIGN MANUAL

75LC span (mm)


Limit State Capacity Tables overall purlin length =
span + 70mm

75LC10 75LC12
Bridging (kN/m) Bridging (kN/m)
Span Span
k Inward Outward k Inward Outward
(mm) L /150 (mm) L /150
0,1,2,3 0 1 2 3 0 1,2,3 0 1 2 3

2100 1.64 8.6 2.74 1.81 2.74 2100 2.08 6.7 3.52 2.41 3.52
2400 1.10 14.6 2.10 1.17 2.10 2400 1.39 11.5 2.69 1.58 2.62 2.70
2700 0.77 23.4 1.66 0.82 1.55 1.66 2700 0.98 18.4 2.11 1.07 1.88 2.13
3000 0.56 35.7 1.34 0.57 1.16 1.34 3000 0.71 28.1 1.69 0.74 1.43 1.73
3300 0.42 52.1 1.11 0.41 0.85 1.11 3300 0.54 41.1 1.39 1.43 0.53 1.10 1.43
3600 0.33 73.8 0.93 0.64 0.93 3600 0.41 58.3 1.16 1.20 0.40 0.85 1.11 1.20
3900 0.26 102.0 0.79 0.48 0.75 0.79 3900 0.32 80.2 0.95 1.02 0.66 0.91 1.02
4200 0.20 137.3 0.69 0.62 0.69 4200 0.26 108.1 0.81 0.88 0.52 0.75 0.88
4500 0.17 180.7 0.60 0.51 0.60 4500 0.21 142.2 0.71 0.77 0.41 0.63 0.76
4800 0.14 233.6 0.52 0.41 0.52 4800 0.17 183.9 0.62 0.67 0.53 0.62
5100 0.11 298.2 0.47 0.45 5100 0.15 234.5 0.55 0.60 0.44 0.54
5400 0.12 295.1 0.49 0.53 0.47
5700 0.10 365.4 0.44 0.48 0.40

75LC15
Bridging (kN/m)
Span
k Inward Outward
(mm) L /150
0 1,2,3 0 1 2 3

2100 2.68 5.2 4.35 3.35 4.38


2400 1.79 8.9 3.29 2.18 3.36
2700 1.26 14.3 2.58 2.65 1.47 2.55 2.65
3000 0.92 21.8 2.08 2.15 1.03 1.96 2.15
3300 0.69 31.9 1.70 1.78 0.75 1.53 1.78
3600 0.53 45.2 1.42 1.49 0.57 1.19 1.49
3900 0.42 62.2 1.21 1.27 0.44 0.92 1.23 1.27
4200 0.34 83.6 1.04 1.10 0.72 1.03 1.10
4500 0.27 110.3 0.90 0.96 0.57 0.86 0.96
4800 0.22 142.9 0.79 0.84 0.45 0.73 0.84
5100 0.19 181.8 0.70 0.74 0.61 0.73
5400 0.16 229.3 0.62 0.66 0.52 0.63
5700 0.13 283.6 0.55 0.60 0.43 0.55
6000 0.12 347.8 0.50 0.54 0.49
6300 0.10 424.2 0.45 0.49 0.43

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

28 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15

PURLIN & GIRT DESIGN MANUAL


This page intentionally blank

www.fielders.com.au 29
FINISH ON TOP WITH FIELDERS
10.2

Single Span
PURLIN & GIRT DESIGN MANUAL

100LC/100Z span (mm)


Limit State Capacity Tables overall purlin length =
span + 70mm

100LC10/100Z10 100LC12/100Z12
Bridging (kN/m) Bridging (kN/m)
Span Span
k Inward Outward k Inward Outward
(mm) L /150 (mm) L /150
0,1,2,3 0 1 2 3 0 1,2,3 0 1 2 3

2100 3.32 4.2 3.94 2.84 3.94 2100 4.20 3.3 5.09 3.70 5.09
2400 2.23 7.2 3.01 1.80 3.01 2400 2.82 5.7 3.90 2.39 3.90
2700 1.56 11.5 2.38 1.25 2.38 2700 1.98 9.1 3.08 1.56 2.96 3.08
3000 1.14 17.6 1.93 0.85 1.82 1.93 3000 1.44 13.9 2.48 1.07 2.20 2.49
3300 0.86 25.7 1.59 0.60 1.35 1.59 3300 1.08 20.3 2.04 0.76 1.70 2.06
3600 0.66 36.4 1.34 0.43 1.01 1.34 3600 0.83 28.8 1.70 0.56 1.30 1.73
3900 0.52 50.1 1.14 0.77 1.14 3900 0.66 39.6 1.44 1.48 0.42 1.02 1.43 1.48
4200 0.42 67.5 0.98 0.59 0.96 0.98 4200 0.53 53.2 1.24 1.27 0.79 1.16 1.27
4500 0.34 88.8 0.86 0.48 0.79 0.86 4500 0.43 70.3 1.07 1.11 0.61 0.97 1.11
4800 0.28 115.1 0.75 0.65 0.75 4800 0.35 90.9 0.94 0.97 0.48 0.81 0.97
5100 0.23 146.6 0.67 0.53 0.67 5100 0.29 115.6 0.83 0.86 0.68 0.85
5400 0.20 184.6 0.60 0.44 0.60 5400 0.25 145.7 0.74 0.77 0.57 0.73
5700 0.17 228.9 0.53 0.52 5700 0.21 181.0 0.66 0.69 0.48 0.62
6000 0.14 281.7 0.48 0.45 6000 0.18 222.2 0.59 0.62 0.40 0.54
6300 0.12 341.5 0.44 6300 0.16 269.2 0.54 0.57 0.48
6600 0.11 411.2 0.40 6600 0.14 325.9 0.49 0.52 0.42

100LC15/100Z15 100LC19/100Z19
Bridging (kN/m) Bridging (kN/m)
Span Span
k Inward Outward k Inward Outward
(mm) L /150 (mm) L /150
0 1,2,3 0 1 2 3 0 1,2,3 0 1 2 3

2100 5.38 2.6 6.45 4.87 6.50 2100 6.79 2.1 8.08 8.74 6.13 8.74
2400 3.61 4.4 4.88 4.98 3.07 4.98 2400 4.55 3.5 6.06 6.69 3.90 6.69
2700 2.53 7.1 3.81 3.93 2.03 3.84 3.93 2700 3.20 5.6 4.70 5.29 2.62 4.99 5.29
3000 1.85 10.8 3.06 3.19 1.41 2.94 3.19 3000 2.33 8.6 3.75 4.28 1.84 3.77 4.28
3300 1.39 15.9 2.51 2.63 1.01 2.26 2.63 3300 1.75 12.6 3.06 3.54 1.34 2.88 3.54
3600 1.07 22.5 2.10 2.21 0.75 1.74 2.21 3600 1.35 17.8 2.55 2.97 1.00 2.21 2.95
3900 0.84 31.0 1.78 1.89 0.57 1.32 1.86 3900 1.06 24.5 2.15 2.53 0.77 1.68 2.41 2.53
4200 0.67 41.6 1.53 1.63 0.44 1.02 1.55 1.63 4200 0.85 33.0 1.84 2.18 0.61 1.30 1.99 2.18
4500 0.55 54.8 1.32 1.42 0.80 1.29 1.42 4500 0.69 43.5 1.59 1.90 0.49 1.02 1.65 1.90
4800 0.45 71.0 1.16 1.25 0.63 1.08 1.25 4800 0.57 56.2 1.39 1.67 0.40 0.82 1.37 1.66
5100 0.38 90.4 1.02 1.10 0.51 0.91 1.10 5100 0.47 71.7 1.22 1.48 0.66 1.15 1.43
5400 0.32 113.9 0.90 0.98 0.41 0.75 0.95 5400 0.40 90.2 1.08 1.32 0.54 0.95 1.24
5700 0.27 141.3 0.81 0.88 0.62 0.83 5700 0.34 111.8 0.97 1.19 0.45 0.79 1.07
6000 0.23 173.2 0.73 0.80 0.52 0.72 6000 0.29 137.5 0.87 1.07 0.66 0.93
6300 0.20 211.1 0.66 0.72 0.44 0.63 6300 0.25 167.3 0.79 0.97 0.56 0.81
6600 0.17 254.3 0.60 0.66 0.56 6600 0.22 200.9 0.71 0.88 0.47 0.71
6900 0.15 302.6 0.54 0.60 0.49 6900 0.19 240.8 0.65 0.81 0.41 0.62
7200 0.13 358.2 0.50 0.55 0.43 7200 0.17 285.7 0.59 0.74 0.54
7500 0.12 423.7 0.46 0.51 0.37 7500 0.15 335.6 0.55 0.69 0.47

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

30 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15
10.2

PURLIN & GIRT DESIGN MANUAL


Single Span
100LC/100Z span (mm)
Limit State Capacity Tables overall purlin length =
span + 70mm

100LC24/100ZC24
Bridging (kN/m)
Span
(mm) L /150 k Inward Outward
0 1 2,3 0 1 2 3

2100 8.54 1.6 9.67 11.12 8.05 11.12


2400 5.72 2.8 7.22 8.51 5.20 8.51
2700 4.02 4.5 5.59 6.73 3.54 6.38 6.73
3000 2.93 6.8 4.46 5.45 2.52 4.82 5.45
3300 2.20 10.0 3.63 4.50 1.86 3.71 4.50
3600 1.69 14.2 3.02 3.78 1.42 2.89 3.78
3900 1.33 19.5 2.54 3.22 1.11 2.23 3.09 3.22
4200 1.07 26.2 2.17 2.78 0.89 1.74 2.54 2.78
4500 0.87 34.6 1.88 2.42 0.72 1.38 2.11 2.42
4800 0.72 44.8 1.64 2.13 0.60 1.11 1.76 2.13
5100 0.60 57.0 1.44 1.88 0.50 0.91 1.49 1.83
5400 0.50 71.7 1.28 1.67 0.43 0.75 1.26 1.57
5700 0.43 89.0 1.14 1.49 0.63 1.05 1.36
6000 0.37 109.3 1.02 1.33 1.36 0.53 0.88 1.19
6300 0.32 132.9 0.92 1.20 1.24 0.45 0.75 1.04
6600 0.28 160.0 0.84 1.09 1.13 0.64 0.91
6900 0.24 190.9 0.76 1.00 1.03 0.55 0.80
7200 0.21 226.4 0.70 0.91 0.95 0.48 0.71
7500 0.19 267.4 0.64 0.84 0.87 0.42 0.62
7800 0.17 311.4 0.59 0.77 0.81 0.54
8100 0.15 362.4 0.54 0.71 0.75 0.48
8400 0.13 421.1 0.50 0.66 0.70 0.42

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

www.fielders.com.au 31
FINISH ON TOP WITH FIELDERS
10.3

Single Span
PURLIN & GIRT DESIGN MANUAL

100FC - Refer details page 7 span (mm)


Limit State Capacity Tables overall purlin length =
span + 70mm

100FC10 100FC12
Bridging (kN/m) Bridging (kN/m)
Span Span
k Inward Outward k Inward Outward
(mm) L /150 (mm) L /150
0,1,2,3 0 1 2 3 0 1,2,3 0 1 2 3

2100 3.69 3.8 4.08 3.30 4.08 2100 4.46 3.1 4.95 4.01 4.95
2400 2.47 6.5 3.13 2.12 3.13 2400 2.99 5.4 3.79 2.52 3.79
2700 1.74 10.4 2.47 1.43 2.47 2700 2.10 8.6 3.00 1.75 3.00
3000 1.27 15.8 2.00 0.98 2.00 3000 1.53 13.1 2.43 1.26 2.39
3300 0.95 23.2 1.65 0.73 1.55 1.65 3300 1.15 19.2 2.01 0.91 1.84 2.01
3600 0.73 32.8 1.39 0.55 1.17 1.39 3600 0.88 27.1 1.69 0.67 1.42 1.69
3900 0.58 45.1 1.18 0.42 0.90 1.18 3900 0.70 37.4 1.44 0.51 1.10 1.44
4200 0.46 60.7 1.02 0.70 1.02 4200 0.56 50.3 1.24 0.83 1.24
4500 0.38 80.0 0.89 0.55 0.89 4500 0.45 66.2 1.07 0.67 1.05 1.08
4800 0.31 103.6 0.78 0.44 0.74 0.78 4800 0.37 85.8 0.94 0.55 0.88 0.95
5100 0.26 132.3 0.69 0.61 0.69 5100 0.31 109.3 0.83 0.45 0.74 0.84
5400 0.22 165.9 0.62 0.51 0.62 5400 0.26 137.4 0.73 0.75 0.62 0.75
5700 0.18 206.5 0.55 0.42 0.55 5700 0.22 170.4 0.66 0.67 0.52 0.67
6000 0.16 253.2 0.50 0.50 6000 0.19 209.4 0.59 0.61 0.42 0.59
6300 0.14 306.6 0.45 0.44 6300 0.17 254.5 0.53 0.55 0.52
6600 0.14 305.6 0.48 0.50 0.45

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

32 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15
10.3

PURLIN & GIRT DESIGN MANUAL


Single Span
100FC - Refer details page 7 span (mm)
Limit State Capacity Tables overall purlin length =
span + 70mm

100FC15 100FC19
Bridging (kN/m) Bridging (kN/m)
Span Span
k Inward Outward k Inward Outward
(mm) L /150 (mm) L /150
0 1,2,3 0 1 2 3 0 1,2,3 0 1 2 3

2100 5.61 2.5 6.16 6.40 5.27 6.40 2100 7.27 1.9 8.37 8.98 7.25 8.98
2400 3.76 4.3 4.65 4.90 3.54 4.90 2400 4.87 3.3 6.26 6.88 4.79 6.88
2700 2.64 6.8 3.63 3.87 2.40 3.82 2700 3.42 5.3 4.85 5.44 3.25 5.41
3000 1.92 10.4 2.91 3.14 1.68 2.95 3.14 3000 2.50 8.0 3.87 4.40 2.27 4.19 4.40
3300 1.45 15.2 2.38 2.59 1.22 2.31 2.59 3300 1.87 11.7 3.15 3.64 1.65 3.26 3.64
3600 1.11 21.6 1.99 2.18 0.90 1.84 2.18 3600 1.44 16.6 2.62 3.06 1.23 2.56 3.06
3900 0.88 29.7 1.68 1.86 0.68 1.47 1.84 3900 1.14 22.9 2.21 2.61 0.94 2.04 2.61
4200 0.70 39.9 1.44 1.60 0.53 1.17 1.54 1.60 4200 0.91 30.8 1.89 2.25 0.74 1.60 2.18 2.25
4500 0.57 52.6 1.25 1.39 0.42 0.94 1.30 1.39 4500 0.74 40.6 1.63 1.96 0.59 1.28 1.84 1.96
4800 0.47 68.2 1.09 1.23 0.75 1.10 1.23 4800 0.61 52.5 1.42 1.72 0.48 1.02 1.55 1.72
5100 0.39 87.0 0.97 1.09 0.61 0.94 1.09 5100 0.51 66.9 1.25 1.52 0.40 0.83 1.31 1.52
5400 0.33 109.1 0.86 0.97 0.50 0.81 0.95 5400 0.43 84.1 1.11 1.36 0.68 1.12 1.34
5700 0.28 135.7 0.77 0.87 0.42 0.69 0.83 5700 0.36 104.4 0.99 1.22 0.56 0.96 1.18
6000 0.24 166.7 0.69 0.78 0.59 0.73 6000 0.31 128.2 0.89 1.10 0.47 0.81 1.04
6300 0.21 201.9 0.62 0.71 0.51 0.64 6300 0.27 156.1 0.80 1.00 0.40 0.69 0.91
6600 0.18 243.1 0.57 0.65 0.44 0.57 6600 0.23 188.0 0.73 0.91 0.60 0.80
6900 0.16 291.1 0.52 0.59 0.51 6900 0.21 224.4 0.67 0.83 0.51 0.71
7200 0.14 345.3 0.47 0.55 0.45 7200 0.18 266.7 0.61 0.76 0.44 0.63
7500 0.12 406.5 0.44 0.50 0.41 7500 0.16 312.5 0.56 0.70 0.56
7800 0.14 366.2 0.52 0.65 0.50
8100 0.13 425.2 0.48 0.60 0.44

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

www.fielders.com.au 33
FINISH ON TOP WITH FIELDERS
10.4

Single Span
PURLIN & GIRT DESIGN MANUAL

150LC/150Z span (mm)


Limit State Capacity Tables overall purlin length =
span + 70mm

150LC12/150Z12 150LC15/150Z15
Bridging (kN/m) Bridging (kN/m)
Span Span
k Inward Outward k Inward Outward
(mm) L /150 (mm) L /150
0 1,2,3 0 1 2 3 0 1,2,3 0 1 2 3

3000 4.54 4.4 4.54 3.43 4.54 3000 5.79 3.5 5.53 5.78 4.22 5.78
3300 3.41 6.4 3.75 2.49 3.75 3300 4.35 5.1 4.50 4.78 3.16 4.78
3600 2.63 9.1 3.15 1.86 3.15 3600 3.35 7.2 3.72 4.02 2.40 4.02
3900 2.07 12.6 2.68 1.43 2.69 3900 2.64 9.9 3.13 3.42 1.79 3.42
4200 1.66 16.9 2.29 1.11 2.29 4200 2.11 13.3 2.67 2.95 1.37 2.82 2.95
4500 1.35 22.3 1.99 0.86 1.91 2.02 4500 1.72 17.5 2.30 2.57 1.07 2.33 2.57
4800 1.11 28.9 1.74 1.77 0.67 1.54 1.77 4800 1.41 22.6 2.00 2.26 0.84 1.92 2.26
5100 0.93 36.8 1.53 1.57 0.54 1.26 1.57 5100 1.18 28.8 1.76 2.00 0.68 1.55 2.00
5400 0.78 46.2 1.36 1.40 0.44 1.04 1.40 5400 0.99 36.3 1.56 1.79 0.55 1.29 1.79
5700 0.66 57.4 1.21 1.26 0.87 1.26 5700 0.84 45.0 1.38 1.60 0.45 1.09 1.60
6000 0.57 70.4 1.09 1.14 0.73 1.14 6000 0.72 55.2 1.24 1.45 0.93 1.41 1.45
6300 0.49 85.5 0.98 1.03 0.62 1.01 1.03 6300 0.63 67.2 1.11 1.31 0.80 1.24 1.31
6600 0.43 103.0 0.89 0.94 0.53 0.89 0.94 6600 0.54 80.9 1.01 1.20 0.68 1.09 1.20
6900 0.37 123.3 0.81 0.86 0.45 0.77 0.86 6900 0.48 96.6 0.91 1.09 0.57 0.95 1.09
7200 0.33 145.9 0.74 0.79 0.67 0.79 7200 0.42 114.6 0.83 1.00 0.49 0.83 1.00
7500 0.29 171.8 0.68 0.73 0.58 0.73 7500 0.37 134.8 0.76 0.93 0.42 0.72 0.93
7800 0.26 201.6 0.63 0.67 0.51 0.67 7800 0.33 158.1 0.70 0.86 0.64 0.85
8100 0.23 233.8 0.58 0.62 0.45 0.62 8100 0.29 183.7 0.65 0.79 0.56 0.77
8400 0.21 270.5 0.53 0.58 0.57 8400 0.26 212.1 0.60 0.74 0.50 0.70
8700 0.19 311.8 0.49 0.54 0.52 8700 0.24 244.7 0.55 0.69 0.45 0.63
9000 0.17 357.1 0.46 0.50 0.47 9000 0.21 280.4 0.51 0.64 0.41 0.57
9300 0.15 407.9 0.43 0.47 0.42 9300 0.19 319.6 0.48 0.60 0.52
9600 0.18 361.6 0.45 0.57 0.47
9900 0.16 409.9 0.42 0.53 0.42

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

34 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15
10.4

PURLIN & GIRT DESIGN MANUAL


Single Span
150LC/150Z span (mm)
Limit State Capacity Tables overall purlin length =
span + 70mm

150LC19/150Z19 150LC24/150Z24
Bridging (kN/m) Bridging (kN/m)
Span Span
L /150 k Inward Outward k Inward Outward
(mm) (mm) L /150
0 1 2,3 0 1 2 3 0 1 2 3 0 1 2 3

3000 7.31 2.7 6.82 7.95 5.77 7.95 3000 9.37 2.1 8.47 10.81 7.46 10.81
3300 5.49 4.0 5.53 6.57 4.19 6.57 3300 7.04 3.1 6.75 8.93 5.39 8.93
3600 4.23 5.7 4.58 5.52 3.07 5.38 5.52 3600 5.42 4.4 5.50 7.50 3.98 7.38
3900 3.33 7.8 3.83 4.71 2.31 4.41 4.71 3900 4.27 6.1 4.57 6.39 3.01 6.05 6.39
4200 2.67 10.5 3.25 4.06 1.77 3.65 4.06 4200 3.42 8.2 3.86 5.51 2.33 4.95 5.51
4500 2.17 13.9 2.79 3.53 1.39 3.05 3.53 4500 2.78 10.8 3.30 4.80 1.83 4.08 4.80
4800 1.79 17.9 2.42 3.11 1.10 2.56 3.11 4800 2.29 14.0 2.85 4.22 1.47 3.38 4.22
5100 1.49 22.8 2.12 2.75 0.89 2.13 2.73 5100 1.91 17.8 2.49 3.71 1.19 2.77 3.74
5400 1.25 28.7 1.87 2.45 0.73 1.77 2.37 2.45 5400 1.61 22.4 2.19 3.28 0.99 2.30 3.25 3.34
5700 1.07 35.6 1.67 2.19 0.60 1.48 2.07 2.20 5700 1.37 27.8 1.94 2.92 2.99 0.82 1.91 2.84 2.99
6000 0.91 43.8 1.49 1.97 0.51 1.23 1.82 1.99 6000 1.17 34.2 1.73 2.61 2.70 0.69 1.60 2.48 2.70
6300 0.79 53.2 1.34 1.77 0.43 1.03 1.60 1.80 6300 1.01 41.5 1.55 2.35 2.45 0.59 1.34 2.16 2.45
6600 0.69 64.0 1.21 1.61 1.64 0.87 1.42 1.64 6600 0.88 50.0 1.40 2.13 2.23 0.51 1.14 1.90 2.23
6900 0.60 76.5 1.10 1.46 1.50 0.74 1.26 1.48 6900 0.77 59.7 1.26 1.93 2.04 0.44 0.97 1.67 2.03
7200 0.53 90.7 1.00 1.34 1.38 0.64 1.11 1.33 7200 0.68 70.8 1.15 1.76 1.88 0.83 1.46 1.83
7500 0.47 106.8 0.92 1.23 1.27 0.55 0.98 1.21 7500 0.60 83.3 1.05 1.61 1.73 0.72 1.28 1.65
7800 0.42 125.0 0.84 1.13 1.18 0.47 0.87 1.09 7800 0.53 97.6 0.96 1.48 1.60 0.63 1.13 1.49
8100 0.37 145.6 0.78 1.04 1.09 0.41 0.77 0.99 8100 0.48 113.4 0.89 1.36 1.48 0.55 1.00 1.35
8400 0.33 168.2 0.72 0.97 1.01 0.68 0.90 8400 0.43 131.1 0.82 1.26 1.37 0.48 0.88 1.22
8700 0.30 193.3 0.66 0.90 0.95 0.60 0.82 8700 0.38 151.0 0.76 1.17 1.27 0.43 0.77 1.10
9000 0.27 221.4 0.62 0.84 0.88 0.53 0.75 9000 0.35 172.9 0.71 1.09 1.18 0.69 1.00
9300 0.25 253.1 0.57 0.78 0.83 0.47 0.69 9300 0.32 196.8 0.66 1.01 1.10 1.12 0.61 0.91
9600 0.22 287.0 0.54 0.73 0.77 0.42 0.63 9600 0.29 223.8 0.61 0.95 1.03 1.06 0.54 0.82
9900 0.20 325.1 0.50 0.69 0.73 0.57 9900 0.26 252.9 0.57 0.89 0.96 0.99 0.49 0.74
10200 0.19 365.6 0.47 0.64 0.68 0.52 10200 0.24 285.7 0.54 0.83 0.90 0.94 0.44 0.67
10500 0.17 409.4 0.44 0.61 0.64 0.47 10500 0.22 319.6 0.51 0.78 0.85 0.88 0.40 0.61
10800 0.16 458.6 0.42 0.57 0.60 0.43 10800 0.20 358.2 0.48 0.74 0.80 0.83 0.56
11100 0.19 400.0 0.45 0.69 0.75 0.79 0.51
11400 0.17 444.4 0.42 0.66 0.71 0.75 0.46
11700 0.16 493.7 0.40 0.62 0.67 0.71 0.42

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

www.fielders.com.au 35
FINISH ON TOP WITH FIELDERS
10.5

Single Span
PURLIN & GIRT DESIGN MANUAL

200LC/200Z span (mm)


Limit State Capacity Tables overall purlin length =
span + 70mm

200LC15/200Z15 200LC19/200Z19
Bridging (kN/m) Bridging (kN/m)
Span Span
k Inward Outward L /150 k Inward Outward
(mm) L /150 (mm)
0 1,2,3 0 1 2 3 0 1 2,3 0 1 2 3

3000 12.18 1.6 7.91 7.57 7.91 3000 16.24 1.2 10.62 11.80 10.70 11.80
3300 9.15 2.4 6.43 5.65 6.54 3300 12.20 1.8 8.45 9.75 7.71 9.75
3600 7.05 3.4 5.33 5.50 4.23 5.50 3600 9.40 2.6 6.75 8.19 5.90 8.19
3900 5.54 4.7 4.48 4.68 3.23 4.68 3900 7.39 3.5 5.50 6.98 4.62 6.98
4200 4.44 6.3 3.81 4.04 2.51 4.04 4200 5.92 4.7 4.63 6.02 3.65 6.02
4500 3.61 8.3 3.28 3.52 1.95 3.52 4500 4.81 6.2 3.96 5.24 2.88 5.24
4800 2.97 10.8 2.85 3.09 1.59 3.09 4800 3.97 8.1 3.42 4.61 2.29 4.58
5100 2.48 13.7 2.48 2.74 1.31 2.70 5100 3.31 10.3 2.98 4.08 1.84 3.88 4.08
5400 2.09 17.2 2.18 2.44 1.08 2.33 2.44 5400 2.79 12.9 2.63 3.64 1.49 3.31 3.64
5700 1.78 21.4 1.93 2.19 0.89 1.98 2.19 5700 2.37 16.0 2.33 3.27 1.22 2.80 3.27
6000 1.52 26.3 1.73 1.98 0.74 1.67 1.98 6000 2.03 19.7 2.08 2.95 1.01 2.30 2.95
6300 1.32 31.9 1.55 1.79 0.62 1.42 1.79 6300 1.75 23.9 1.87 2.68 0.85 1.98 2.68
6600 1.14 38.5 1.40 1.64 0.52 1.21 1.64 6600 1.53 28.9 1.69 2.44 0.72 1.71 2.44
6900 1.00 46.0 1.27 1.50 0.44 1.04 1.50 6900 1.34 34.5 1.53 2.23 0.61 1.49 2.23
7200 0.88 54.5 1.15 1.37 0.90 1.37 7200 1.18 40.9 1.39 2.05 0.52 1.31 2.01 2.05
7500 0.78 64.2 1.05 1.27 0.78 1.25 7500 1.04 48.1 1.28 1.89 0.45 1.14 1.79 1.89
7800 0.69 75.0 0.97 1.17 0.67 1.13 1.17 7800 0.92 56.3 1.17 1.75 1.00 1.61 1.75
8100 0.62 87.2 0.89 1.09 0.59 1.02 1.09 8100 0.83 65.5 1.08 1.62 0.87 1.44 1.62
8400 0.56 100.9 0.82 1.01 0.53 0.91 1.01 8400 0.74 75.7 1.00 1.50 0.77 1.28 1.50
8700 0.50 116.2 0.76 0.94 0.47 0.81 0.94 8700 0.67 87.1 0.92 1.40 0.67 1.11 1.40
9000 0.45 133.0 0.71 0.88 0.42 0.72 0.88 9000 0.60 99.7 0.86 1.31 0.59 1.00 1.31
9300 0.41 151.6 0.66 0.82 0.65 0.82 9300 0.55 113.8 0.80 1.23 0.53 0.90 1.23
9600 0.37 172.0 0.62 0.77 0.58 0.77 9600 0.50 129.0 0.75 1.14 0.47 0.82 1.13
9900 0.34 194.7 0.58 0.73 0.52 0.72 9900 0.45 146.0 0.70 1.07 0.42 0.74 1.04
10200 0.31 219.4 0.54 0.69 0.47 0.67 10200 0.41 164.6 0.66 1.00 0.68 0.96
10500 0.28 246.5 0.51 0.65 0.43 0.62 10500 0.38 184.7 0.62 0.94 0.96 0.62 0.88
10800 0.26 275.9 0.48 0.61 0.57 10800 0.35 206.9 0.58 0.89 0.91 0.57 0.81
11100 0.24 308.3 0.45 0.58 0.53 11100 0.32 230.5 0.55 0.84 0.86 0.52 0.74
11400 0.22 342.3 0.42 0.55 0.48 11400 0.30 256.8 0.52 0.79 0.82 0.47 0.67
11700 0.21 380.5 0.40 0.52 0.44 11700 0.27 284.7 0.49 0.75 0.78 0.43 0.61
12000 0.19 421.1 0.50 0.41 12000 0.25 315.0 0.46 0.71 0.74 0.56

12300 0.24 347.5 0.44 0.67 0.70 0.52


12600 0.22 383.6 0.42 0.64 0.67 0.48
12900 0.20 421.6 0.40 0.61 0.64 0.45
13200 0.19 460.7 0.38 0.58 0.61 0.42

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

36 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15
10.5

PURLIN & GIRT DESIGN MANUAL


Single Span
200LC/200Z span (mm)
Limit State Capacity Tables overall purlin length =
span + 70mm

200LC24/200Z24
Bridging (kN/m)
Span
k Inward Outward
(mm) L /150
0 1 2 3 0 1 2 3

3000 20.50 1.0 13.41 16.51 14.32 16.51


3300 15.40 1.4 10.56 13.65 10.85 13.65
3600 11.86 2.0 8.47 11.47 8.09 11.47
3900 9.33 2.8 6.95 9.77 6.19 9.77
4200 7.47 3.7 5.80 8.42 4.80 8.42
4500 6.07 4.9 4.91 7.34 3.75 7.10 7.34
4800 5.01 6.4 4.22 6.45 2.97 6.03 6.45
5100 4.17 8.1 3.66 5.71 2.39 5.16 5.71
5400 3.52 10.2 3.20 5.06 1.95 4.43 5.10
5700 2.99 12.7 2.83 4.49 1.60 3.81 4.57
6000 2.56 15.6 2.52 4.01 4.13 1.34 3.25 4.13
6300 2.21 19.0 2.25 3.60 3.74 1.12 2.75 3.71
6600 1.93 22.9 2.02 3.25 3.41 0.95 2.35 3.31 3.41
6900 1.69 27.3 1.82 2.94 3.12 0.81 2.02 2.96 3.12
7200 1.48 32.4 1.66 2.68 2.87 0.70 1.75 2.65 2.87
7500 1.31 38.1 1.51 2.45 2.64 0.61 1.52 2.38 2.64
7800 1.17 44.6 1.38 2.25 2.44 0.53 1.31 2.15 2.44
8100 1.04 51.9 1.27 2.07 2.27 0.47 1.14 1.94 2.27
8400 0.93 60.0 1.17 1.91 2.11 0.41 1.00 1.75 2.09
8700 0.84 69.0 1.08 1.77 1.96 0.88 1.57 1.91
9000 0.76 79.1 1.00 1.65 1.82 0.78 1.40 1.76
9300 0.69 90.1 0.93 1.53 1.70 0.69 1.25 1.62
9600 0.63 102.2 0.87 1.43 1.58 1.61 0.61 1.13 1.49
9900 0.57 115.8 0.81 1.34 1.48 1.52 0.55 1.01 1.38
10200 0.52 130.3 0.76 1.25 1.38 1.43 0.49 0.92 1.27
10500 0.48 146.4 0.71 1.18 1.30 1.35 0.44 0.83 1.18
10800 0.44 164.0 0.67 1.11 1.22 1.27 0.40 0.76 1.09
11100 0.41 182.7 0.63 1.05 1.15 1.21 0.68 1.01
11400 0.37 203.2 0.59 0.99 1.08 1.14 0.62 0.93
11700 0.35 225.4 0.56 0.93 1.02 1.09 0.56 0.86
12000 0.32 250.0 0.53 0.88 0.97 1.03 0.51 0.79

12300 0.30 276.1 0.50 0.84 0.92 0.98 0.47 0.73


12600 0.28 303.2 0.47 0.80 0.87 0.93 0.43 0.67
12900 0.26 333.3 0.45 0.76 0.83 0.88 0.62
13200 0.24 365.1 0.43 0.72 0.79 0.84 0.57
13500 0.23 400.0 0.41 0.69 0.75 0.80 0.53
13800 0.21 436.0 0.65 0.71 0.76 0.49
14100 0.20 477.2 0.62 0.68 0.72 0.46
14400 0.19 518.9 0.60 0.65 0.69 0.43

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

www.fielders.com.au 37
FINISH ON TOP WITH FIELDERS
10.6

Single Span
PURLIN & GIRT DESIGN MANUAL

250LC/250Z span (mm)


Limit State Capacity Tables overall purlin length =
span + 70mm

250LC19/250Z19 250LC24/250Z24
Bridging (kN/m) Bridging (kN/m)
Span Span
L /150 k Inward Outward k Inward Outward
(mm) (mm) L /150
0 1 0 1 2 3 0 1 2 3 0 1 2 3

3600 15.30 1.6 8.42 10.01 7.53 10.01 3600 19.65 1.2 10.58 14.49 9.53 14.49
3900 12.04 2.2 6.97 8.53 5.73 8.53 3900 15.45 1.7 8.64 12.35 7.13 12.35
4200 9.64 2.9 5.86 7.36 4.36 7.36 4200 12.37 2.3 7.19 10.65 5.44 10.65
4500 7.84 3.8 5.00 6.41 3.38 6.41 4500 10.06 3.0 6.07 9.27 4.23 9.27
4800 6.46 5.0 4.31 5.63 2.66 5.63 4800 8.29 3.9 5.19 8.15 3.34 7.88 8.15
5100 5.38 6.3 3.75 4.99 2.13 4.93 5100 6.91 4.9 4.49 7.22 2.68 6.64 7.22
5400 4.53 7.9 3.30 4.45 1.72 4.15 4.45 5400 5.82 6.2 3.92 6.44 2.17 5.50 6.44
5700 3.86 9.9 2.92 3.99 1.41 3.51 3.99 5700 4.95 7.7 3.45 5.78 1.78 4.59 5.78
6000 3.31 12.1 2.60 3.60 1.16 2.96 3.60 6000 4.24 9.4 3.06 5.22 1.48 3.87 5.22
6300 2.86 14.7 2.34 3.27 0.97 2.53 3.27 6300 3.67 11.5 2.73 4.73 1.24 3.25 4.73
6600 2.48 17.7 2.11 2.98 0.82 2.17 2.98 6600 3.19 13.8 2.45 4.31 1.05 2.74 4.31
6900 2.17 21.2 1.91 2.73 0.70 1.86 2.73 6900 2.79 16.5 2.21 3.93 0.90 2.33 3.87
7200 1.91 25.1 1.74 2.50 0.59 1.59 2.50 7200 2.46 19.5 2.01 3.58 0.77 1.99 3.46 3.62
7500 1.69 29.6 1.59 2.31 0.51 1.36 2.28 7500 2.17 23.0 1.83 3.27 3.34 0.67 1.71 3.07 3.34
7800 1.51 34.6 1.46 2.13 0.44 1.18 2.03 2.13 7800 1.93 26.9 1.67 3.00 3.09 0.58 1.48 2.70 3.09
8100 1.34 40.2 1.34 1.98 1.02 1.80 1.98 8100 1.73 31.3 1.54 2.76 2.86 0.51 1.28 2.38 2.86
8400 1.21 46.5 1.24 1.84 0.89 1.61 1.84 8400 1.55 36.2 1.42 2.55 2.66 0.45 1.12 2.10 2.66
8700 1.08 53.5 1.15 1.71 0.78 1.43 1.71 8700 1.39 41.7 1.31 2.36 2.48 0.98 1.87 2.48
9000 0.98 61.3 1.07 1.60 0.69 1.28 1.60 9000 1.26 47.7 1.21 2.19 2.32 0.87 1.67 2.31
9300 0.89 69.8 1.00 1.50 0.61 1.15 1.50 9300 1.14 54.4 1.13 2.03 2.17 0.77 1.48 2.12
9600 0.81 79.3 0.93 1.41 0.54 1.04 1.41 9600 1.04 61.8 1.05 1.89 2.04 0.68 1.32 1.94
9900 0.74 89.7 0.87 1.32 0.48 0.94 1.32 9900 0.95 69.8 0.98 1.77 1.92 0.61 1.17 1.78
10200 0.67 101.0 0.82 1.25 0.43 0.84 1.21 10200 0.86 78.7 0.92 1.66 1.81 0.55 1.05 1.62
10500 0.62 113.5 0.77 1.18 0.76 1.11 10500 0.79 88.4 0.86 1.55 1.70 0.49 0.95 1.47
10800 0.57 127.0 0.72 1.11 0.68 1.02 10800 0.73 98.9 0.81 1.46 1.61 0.44 0.85 1.34
11100 0.52 141.8 0.68 1.05 0.61 0.93 11100 0.67 110.4 0.76 1.37 1.52 0.77 1.22
11400 0.48 157.7 0.64 1.00 0.56 0.85 11400 0.62 122.8 0.72 1.29 1.45 0.70 1.12
11700 0.45 174.9 0.61 0.95 0.50 0.78 11700 0.57 136.4 0.68 1.21 1.37 0.63 1.02
12000 0.41 193.7 0.57 0.90 0.46 0.72 12000 0.53 150.9 0.64 1.15 1.30 0.58 0.94

12300 0.38 213.5 0.55 0.86 0.42 0.67 12300 0.49 166.3 0.61 1.08 1.23 0.53 0.86
12600 0.36 235.3 0.52 0.82 0.62 12600 0.46 183.4 0.58 1.03 1.16 0.48 0.79
12900 0.33 258.3 0.49 0.78 0.57 12900 0.43 201.4 0.55 0.97 1.11 1.13 0.44 0.72
13200 0.31 283.9 0.47 0.75 0.53 13200 0.40 220.6 0.52 0.93 1.05 1.08 0.40 0.66
13500 0.29 310.3 0.45 0.71 0.49 13500 0.37 241.3 0.50 0.88 1.00 1.03 0.61
13800 0.27 338.2 0.43 0.68 0.45 13800 0.35 263.6 0.47 0.84 0.95 0.99 0.56
14100 0.26 368.6 0.41 0.65 0.42 14100 0.33 287.5 0.45 0.80 0.91 0.95 0.52
14400 0.31 312.7 0.43 0.76 0.87 0.91 0.48
14700 0.29 339.1 0.41 0.73 0.83 0.87 0.44
15000 0.27 367.6 0.70 0.79 0.84 0.41

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

38 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15
10.7

Single Span

PURLIN & GIRT DESIGN MANUAL


300LC span (mm)
Limit State Capacity Tables overall purlin length =
span + 70mm

300LC24 300LC30
Bridging (kN/m) Bridging (kN/m)
Span Span
k Inward Outward k Inward Outward
(mm) L /150 (mm) L /150
0 1 2 3 0 1 2 3 0 1 2 3 0 1 2 3

3600 34.81 0.7 15.94 20.24 19.87 3600 44.73 0.5 21.37 28.94 27.13 28.94
3900 27.38 0.9 12.99 17.25 15.79 17.25 3900 35.18 0.7 16.89 24.66 22.01 24.66
4200 21.92 1.3 10.78 14.87 12.38 14.87 4200 28.17 1.0 13.64 21.26 17.56 21.26
4500 17.82 1.7 9.08 12.96 9.78 12.96 4500 22.90 1.3 11.21 18.52 13.97 18.52
4800 14.68 2.2 7.75 11.39 8.02 11.39 4800 18.87 1.7 9.36 16.28 11.08 16.28
5100 12.24 2.8 6.69 10.09 6.65 10.09 5100 15.73 2.2 7.92 14.42 8.90 14.42
5400 10.31 3.5 5.79 9.00 5.47 9.00 5400 13.25 2.7 6.78 12.86 7.23 12.86
5700 8.77 4.3 5.06 8.08 4.52 8.08 5700 11.27 3.4 5.87 11.54 5.94 11.54
6000 7.52 5.3 4.45 7.29 3.74 7.29 6000 9.66 4.1 5.12 10.42 4.92 10.25
6300 6.49 6.5 3.95 6.61 3.12 6.61 6300 8.35 5.0 4.51 9.40 4.12 9.06 9.45
6600 5.65 7.8 3.53 6.02 2.63 5.86 6.02 6600 7.26 6.1 4.00 8.44 8.61 3.47 8.04 8.61
6900 4.94 9.3 3.17 5.51 2.23 5.17 5.51 6900 6.35 7.2 3.57 7.61 7.88 2.95 7.16 7.88
7200 4.35 11.0 2.85 5.06 1.90 4.52 5.06 7200 5.59 8.6 3.21 6.90 7.23 2.53 6.40 7.23
7500 3.85 13.0 2.58 4.66 1.64 3.95 4.66 7500 4.95 10.1 2.90 6.27 6.67 2.18 5.64 6.67
7800 3.42 15.2 2.35 4.31 1.42 3.40 4.31 7800 4.40 11.8 2.63 5.73 6.16 1.89 4.95 6.16
8100 3.06 17.7 2.14 4.00 1.23 3.03 4.00 8100 3.93 13.8 2.40 5.24 5.72 1.65 4.37 5.72
8400 2.74 20.4 1.97 3.67 1.08 2.71 3.72 8400 3.52 15.9 2.19 4.82 5.32 1.44 3.84 5.32
8700 2.47 23.5 1.81 3.38 3.47 0.95 2.43 3.47 8700 3.17 18.3 2.01 4.44 4.96 1.27 3.38 4.91
9000 2.23 26.9 1.67 3.12 3.24 0.84 2.19 3.24 9000 2.86 21.0 1.86 4.10 4.63 1.12 2.99 4.51 4.63
9300 2.02 30.7 1.54 2.89 3.03 0.74 1.97 3.03 9300 2.60 23.9 1.72 3.79 4.34 1.00 2.65 4.15 4.34
9600 1.84 34.9 1.43 2.69 2.85 0.66 1.76 2.79 9600 2.36 27.1 1.59 3.50 4.07 0.89 2.36 3.83 4.07
9900 1.67 39.4 1.33 2.50 2.68 0.59 1.58 2.56 2.68 9900 2.15 30.7 1.48 3.23 3.83 0.80 2.10 3.53 3.83
10200 1.53 44.4 1.24 2.33 2.52 0.53 1.42 2.35 2.52 10200 1.97 34.6 1.38 3.00 3.60 0.72 1.88 3.27 3.61
10500 1.40 49.9 1.16 2.17 2.38 0.48 1.27 2.15 2.38 10500 1.80 38.8 1.29 2.78 3.37 0.65 1.69 3.02 3.40
10800 1.29 55.9 1.09 2.02 2.25 0.43 1.15 1.96 2.25 10800 1.66 43.5 1.21 2.59 3.15 0.59 1.53 2.79 3.22
11100 1.19 62.3 1.02 1.89 2.13 1.04 1.79 2.13 11100 1.53 48.5 1.13 2.42 2.96 3.04 0.53 1.38 2.55 3.04
11400 1.10 69.3 0.96 1.77 2.02 0.94 1.63 2.02 11400 1.41 53.9 1.06 2.26 2.78 2.89 0.49 1.25 2.34 2.88
11700 1.01 76.9 0.91 1.67 1.92 0.85 1.48 1.92 11700 1.30 59.9 1.00 2.12 2.62 2.74 0.44 1.13 2.15 2.70
12000 0.94 85.1 0.86 1.57 1.82 0.77 1.37 1.82 12000 1.21 66.2 0.95 1.99 2.47 2.60 0.41 1.03 1.97 2.54

12300 0.87 93.9 0.81 1.48 1.73 0.70 1.27 1.73 12300 1.12 73.1 0.89 1.87 2.34 2.48 0.94 1.80 2.38
12600 0.81 103.4 0.77 1.39 1.65 0.64 1.18 1.64 12600 1.04 80.5 0.85 1.76 2.21 2.36 0.86 1.65 2.24
12900 0.76 113.8 0.73 1.32 1.58 0.59 1.09 1.54 12900 0.97 88.5 0.80 1.65 2.09 2.25 0.79 1.51 2.11
13200 0.71 124.6 0.69 1.25 1.51 0.54 1.02 1.44 13200 0.91 97.0 0.76 1.56 1.98 2.15 0.72 1.39 1.99
13500 0.66 136.4 0.66 1.18 1.44 0.50 0.95 1.35 13500 0.85 106.1 0.72 1.47 1.88 2.06 0.67 1.28 1.88
13800 0.62 148.9 0.62 1.12 1.37 0.46 0.88 1.27 13800 0.79 115.9 0.69 1.40 1.79 1.97 0.61 1.18 1.77
14100 0.58 162.3 0.59 1.07 1.30 0.42 0.82 1.18 14100 0.75 126.2 0.65 1.32 1.70 1.88 0.57 1.09 1.67
14400 0.54 176.5 0.57 1.00 1.24 1.27 0.76 1.10 14400 0.70 137.3 0.62 1.25 1.62 1.79 0.53 1.01 1.57
14700 0.51 191.8 0.54 0.95 1.18 1.21 0.71 1.03 14700 0.66 149.2 0.60 1.19 1.55 1.71 0.49 0.94 1.47
15000 0.48 207.9 0.52 0.91 1.13 1.17 0.66 0.96 15000 0.62 161.8 0.57 1.13 1.48 1.63 0.45 0.87 1.38
15300 0.45 225.2 0.50 0.87 1.08 1.12 0.61 0.88 15300 0.58 175.0 0.54 1.08 1.41 1.56 0.42 0.81 1.29
15600 0.43 243.0 0.47 0.83 1.03 1.08 0.57 0.83 15600 0.55 189.1 0.52 1.03 1.34 1.49 0.75 1.21
15900 0.40 262.4 0.45 0.80 0.99 1.04 0.53 0.79 15900 0.52 204.2 0.50 0.98 1.28 1.43 0.70 1.13
16200 0.38 282.7 0.44 0.77 0.94 1.00 0.49 0.74 16200 0.49 220.0 0.48 0.94 1.22 1.37 0.65 1.06
16500 0.36 304.7 0.42 0.73 0.90 0.96 0.46 0.70 16500 0.47 236.6 0.46 0.90 1.17 1.31 0.61 0.99
16800 0.34 327.5 0.40 0.71 0.87 0.93 0.43 0.66 16800 0.44 254.5 0.44 0.86 1.11 1.26 0.57 0.93
17100 0.33 350.8 0.68 0.83 0.90 0.40 0.63 17100 0.42 273.4 0.42 0.82 1.07 1.21 0.54 0.87
17400 0.31 376.6 0.65 0.80 0.87 0.59 17400 0.40 292.9 0.41 0.79 1.02 1.16 0.50 0.82
17700 0.29 402.7 0.63 0.77 0.84 0.56 17700 0.38 313.8 0.76 0.98 1.11 0.47 0.77
18000 0.28 431.7 0.61 0.74 0.81 0.54 18000 0.36 335.2 0.73 0.94 1.07 0.44 0.72

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

www.fielders.com.au 39
FINISH ON TOP WITH FIELDERS
10.8

Single Span
PURLIN & GIRT DESIGN MANUAL

350LC30 span (mm)


Limit State Capacity Tables overall purlin length =
span + 70mm

350LC30
Bridging (kN/m)
Span
k Inward Outward
(mm) L /150
0 1 2 3 0 1 2 3

4500 37.42 0.8 16.32 22.69 22.53


4800 30.84 1.0 13.30 19.94 18.82 19.94
5100 25.71 1.3 11.32 17.67 15.63 17.67
5400 21.66 1.7 9.74 15.76 12.96 15.76
5700 18.41 2.1 8.47 14.14 10.84 14.14
6000 15.79 2.5 7.42 12.76 9.14 12.76
6300 13.64 3.1 6.52 11.58 7.63 11.58
6600 11.86 3.7 5.75 10.55 6.61 10.55
6900 10.38 4.4 5.10 9.65 5.77 9.65
7200 9.14 5.3 4.56 8.86 5.05 8.86
7500 8.08 6.2 4.09 8.17 4.38 8.17
7800 7.19 7.2 3.70 7.55 3.83 7.55
8100 6.42 8.4 3.36 7.00 3.36 7.00
8400 5.75 9.7 3.06 6.51 2.95 6.34 6.51
8700 5.18 11.2 2.79 6.05 2.59 5.74 6.07
9000 4.68 12.8 2.56 5.56 2.28 5.21 5.67
9300 4.24 14.6 2.35 5.13 5.31 2.02 4.68 5.31
9600 3.85 16.6 2.17 4.74 4.99 1.80 4.21 4.99
9900 3.52 18.8 2.00 4.39 4.69 1.60 3.81 4.69
10200 3.21 21.2 1.86 4.07 4.42 1.44 3.45 4.42
10500 2.95 23.8 1.73 3.76 4.17 1.29 3.13 4.17
10800 2.71 26.6 1.61 3.48 3.94 1.16 2.85 3.94
11100 2.49 29.7 1.51 3.24 3.73 1.05 2.60 3.73
11400 2.30 33.0 1.41 3.01 3.54 0.95 2.33 3.54
11700 2.13 36.6 1.32 2.81 3.36 0.87 2.15 3.36
12000 1.97 40.5 1.25 2.63 3.19 0.79 1.99 3.17

12300 1.83 44.7 1.17 2.46 3.04 0.72 1.84 2.96 3.04
12600 1.71 49.3 1.11 2.31 2.89 0.66 1.71 2.77 2.89
12900 1.59 54.1 1.05 2.17 2.76 0.61 1.59 2.59 2.76
13200 1.48 59.3 0.99 2.04 2.64 0.56 1.47 2.43 2.64
13500 1.39 64.9 0.94 1.93 2.52 0.52 1.36 2.25 2.52
13800 1.30 70.9 0.89 1.82 2.41 0.48 1.26 2.10 2.41
14100 1.22 77.3 0.85 1.72 2.31 0.44 1.17 1.95 2.31
14400 1.14 84.1 0.81 1.63 2.20 0.41 1.08 1.82 2.22
14700 1.07 91.2 0.77 1.55 2.09 0.38 1.01 1.70 2.13
15000 1.01 99.0 0.73 1.47 1.99 2.04 0.35 0.94 1.59 2.04
15300 0.95 107.1 0.70 1.40 1.89 1.96 0.33 0.87 1.49 1.96
15600 0.90 115.8 0.67 1.33 1.80 1.89 0.31 0.81 1.40 1.89
15900 0.85 125.0 0.64 1.27 1.72 1.82 0.29 0.75 1.31 1.82
16200 0.80 134.7 0.61 1.18 1.64 1.75 0.27 0.70 1.23 1.73
16500 0.76 144.9 0.59 1.13 1.57 1.69 0.25 0.66 1.13 1.64
16800 0.72 155.8 0.56 1.08 1.50 1.63 0.24 0.61 1.07 1.56
17100 0.68 167.2 0.54 1.04 1.43 1.57 0.22 0.57 1.01 1.48
17400 0.65 179.3 0.52 1.00 1.37 1.52 0.21 0.54 0.96 1.41
17700 0.62 191.9 0.50 0.96 1.30 1.47 0.20 0.50 0.91 1.34
18000 0.59 205.1 0.48 0.92 1.25 1.42 0.19 0.47 0.86 1.27

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

40 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15
10.9

Single Span

PURLIN & GIRT DESIGN MANUAL


400LC30 span (mm)
Limit State Capacity Tables overall purlin length =
span + 70mm

400LC30
Bridging (kN/m)
Span
k Inward Outward
(mm) L /150
0 1 2 3 0 1 2 3

4500 46.10 0.7 15.81 25.98 20.90 25.98


4800 37.99 0.8 13.13 22.83 16.54 22.83
5100 31.67 1.1 11.07 20.22 13.25 20.22
5400 26.68 1.3 9.44 18.04 10.74 18.04
5700 22.68 1.7 8.14 16.19 8.80 16.19
6000 19.45 2.1 7.08 14.61 7.28 14.61
6300 16.80 2.5 6.22 13.25 6.07 13.25
6600 14.61 3.0 5.50 12.08 5.11 12.08
6900 12.79 3.6 4.90 11.05 4.33 11.05
7200 11.26 4.3 4.39 10.15 3.69 9.92 10.15
7500 9.96 5.0 3.95 9.35 3.17 8.63 9.35
7800 8.85 5.9 3.58 8.65 2.74 7.50 8.65
8100 7.90 6.8 3.26 8.01 2.38 6.54 8.02
8400 7.09 7.9 2.97 7.35 2.08 5.73 7.46
8700 6.38 9.1 2.73 6.70 6.95 1.83 5.04 6.95
9000 5.76 10.4 2.51 6.11 6.49 1.61 4.45 6.49
9300 5.22 11.9 2.32 5.57 6.08 1.43 3.94 6.08
9600 4.75 13.5 2.14 5.10 5.71 1.27 3.50 5.71
9900 4.33 15.2 1.99 4.69 5.37 1.14 3.12 5.37
10200 3.96 17.2 1.85 4.32 5.06 1.02 2.79 5.06
10500 3.63 19.3 1.73 3.99 4.77 0.92 2.51 4.71
10800 3.34 21.6 1.62 3.70 4.51 0.83 2.26 4.30 4.51
11100 3.07 24.1 1.52 3.43 4.27 0.75 2.04 3.90 4.27
11400 2.84 26.8 1.42 3.20 4.05 0.68 1.84 3.54 4.05
11700 2.62 29.7 1.34 2.98 3.84 0.62 1.67 3.23 3.84
12000 2.43 32.9 1.26 2.79 3.65 0.56 1.52 2.94 3.65

12300 2.26 36.3 1.19 2.61 3.48 0.52 1.38 2.69 3.48
12600 2.10 40.0 1.13 2.45 3.31 0.47 1.26 2.46 3.31
12900 1.96 43.9 1.07 2.31 3.16 0.44 1.16 2.26 3.16
13200 1.83 48.2 1.01 2.17 3.02 0.40 1.06 2.08 3.02
13500 1.71 52.7 0.96 2.05 2.87 0.37 0.97 1.91 2.89
13800 1.60 57.6 0.91 1.94 2.73 0.34 0.90 1.76 2.75
14100 1.50 62.7 0.87 1.84 2.59 2.65 0.32 0.83 1.63 2.59
14400 1.41 68.2 0.83 1.74 2.45 2.54 0.30 0.76 1.50 2.42
14700 1.32 74.1 0.79 1.65 2.32 2.43 0.27 0.71 1.39 2.25
15000 1.25 80.3 0.76 1.57 2.19 2.34 0.26 0.65 1.29 2.09
15300 1.17 87.0 0.72 1.49 2.07 2.25 0.24 0.61 1.20 1.95
15600 1.11 94.0 0.69 1.42 1.97 2.16 0.22 0.56 1.11 1.82
15900 1.05 101.4 0.66 1.36 1.87 2.08 0.21 0.53 1.04 1.70
16200 0.99 109.3 0.63 1.30 1.77 2.00 0.20 0.49 0.97 1.59
16500 0.94 117.6 0.61 1.24 1.69 1.93 0.18 0.46 0.90 1.48
16800 0.89 126.4 0.58 1.18 1.61 1.86 0.17 0.43 0.84 1.39
17100 0.84 135.7 0.56 1.13 1.53 1.80 0.16 0.40 0.79 1.30
17400 0.80 145.5 0.54 1.09 1.46 1.74 0.15 0.37 0.74 1.22
17700 0.76 155.7 0.52 1.04 1.40 1.68 0.15 0.35 0.69 1.15
18000 0.72 166.7 0.50 1.00 1.34 1.62 0.14 0.33 0.65 1.08

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

www.fielders.com.au 41
FINISH ON TOP WITH FIELDERS
10.10

Double Continuous Spans


PURLIN & GIRT DESIGN MANUAL

75LC span (mm) span (mm)


Limit State Capacity Tables
overall purlin length = 2 x span + 70mm

75LC10 75LC12
Bridging Bridging
Span Span
k Inward Outward k Inward Outward
(mm) L /150 (mm) L /150
0 1,2,3 0 1 2,3 0 1,2,3 0 1 2 3

2100 3.94 3.6 2.74 2.74 2100 4.99 2.8 3.52 3.52
2400 2.64 6.1 2.10 2.10 2400 3.34 4.8 2.68 2.70
2700 1.85 9.7 1.66 1.66 2700 2.35 7.7 2.08 2.13 1.98 2.13
3000 1.35 14.8 1.34 1.27 1.34 3000 1.71 11.7 1.60 1.73 1.53 1.73
3300 1.01 21.7 1.11 0.98 1.11 3300 1.29 17.1 1.30 1.43 1.21 1.43
3600 0.78 30.7 0.93 0.77 0.93 3600 0.99 24.2 1.08 1.20 0.97 1.20
3900 0.61 42.3 0.78 0.79 0.60 0.80 3900 0.78 33.4 0.91 1.02 0.78 1.00 1.02
4200 0.49 56.9 0.66 0.69 0.47 0.66 0.69 4200 0.62 44.9 0.77 0.88 0.63 0.80 0.88
4500 0.40 75.0 0.56 0.60 0.55 0.60 4500 0.51 59.2 0.66 0.77 0.51 0.67 0.77
4800 0.33 97.0 0.48 0.52 0.46 0.52 4800 0.42 76.6 0.57 0.67 0.43 0.57 0.67
5100 0.28 123.6 0.42 0.47 0.47 5100 0.35 97.4 0.50 0.60 0.49 0.60
5400 0.23 155.8 0.41 0.41 5400 0.29 122.4 0.44 0.53 0.42 0.52 0.53
5700 0.25 152.0 0.48 0.44 0.48
6000 0.21 186.9 0.43 0.43

75LC15
Bridging
Span
k Inward Outward
(mm) L /150
0 1,2,3 0 1 2 3

2100 6.44 2.2 4.38 4.38


2400 4.32 3.7 3.32 3.36
2700 3.03 5.9 2.59 2.65 2.65
3000 2.21 9.1 2.07 2.15 2.07 2.15
3300 1.66 13.3 1.69 1.78 1.65 1.78
3600 1.28 18.8 1.40 1.49 1.33 1.49
3900 1.01 25.8 1.18 1.27 1.08 1.27
4200 0.81 34.8 1.01 1.10 0.89 1.08
4500 0.66 45.8 0.87 0.96 0.72 0.92 0.96
4800 0.54 59.4 0.75 0.84 0.60 0.78 0.84
5100 0.45 75.6 0.66 0.74 0.50 0.67 0.74
5400 0.38 95.0 0.58 0.66 0.42 0.58 0.66
5700 0.32 118.0 0.51 0.60 0.50 0.59
6000 0.28 144.9 0.45 0.54 0.44 0.52 0.54

6300 0.24 175.7 0.40 0.49 0.46 0.49


6600 0.21 211.5 0.44 0.41 0.44
6900 0.18 252.7 0.40 0.41

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

42 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15

PURLIN & GIRT DESIGN MANUAL


This page intentionally blank

www.fielders.com.au 43
FINISH ON TOP WITH FIELDERS
10.11

Double Continuous Spans


PURLIN & GIRT DESIGN MANUAL

100LC/100Z span (mm) span (mm)


Limit State Capacity Tables
overall purlin length = 2 x span + 70mm

100LC10/100Z10 100LC12/100Z12
Bridging (kN/m) Bridging (kN/m)
Span Span
k Inward Outward k Inward Outward
(mm) L /150 (mm) L /150
0 1,2,3 0 1 2,3 0 1 0 1 2 3

2100 7.99 1.8 3.83 3.83 2100 10.12 1.4 5.09 5.09
2400 5.35 3.0 3.01 3.01 2400 6.78 2.4 3.90 3.90
2700 3.76 4.8 2.38 2.38 2700 4.76 3.8 3.07 3.08
3000 2.74 7.3 1.93 1.93 3000 3.47 5.8 2.45 2.39 2.49
3300 2.06 10.7 1.59 1.53 1.59 3300 2.61 8.4 1.99 2.06 1.85 2.06
3600 1.59 15.1 1.34 1.19 1.34 3600 2.01 12.0 1.65 1.73 1.47 1.73
3900 1.25 20.8 1.14 0.92 1.14 3900 1.58 16.5 1.35 1.48 1.17 1.48
4200 1.00 28.0 0.98 0.73 0.98 4200 1.27 22.1 1.14 1.27 0.94 1.25
4500 0.81 36.9 0.84 0.58 0.86 4500 1.03 29.2 0.98 1.11 0.77 1.05 1.11
4800 0.67 47.8 0.73 0.75 0.46 0.72 0.75 4800 0.85 37.8 0.85 0.97 0.63 0.87 0.97
5100 0.56 60.9 0.63 0.67 0.61 0.67 5100 0.71 48.2 0.74 0.86 0.51 0.75 0.86
5400 0.47 76.6 0.55 0.60 0.51 0.60 5400 0.60 60.5 0.65 0.77 0.42 0.64 0.77
5700 0.40 95.0 0.48 0.53 0.42 0.53 5700 0.51 75.1 0.57 0.69 0.54 0.68
6000 0.34 116.6 0.42 0.48 0.48 6000 0.43 92.2 0.50 0.62 0.47 0.60 0.62

6300 0.30 141.9 0.44 0.43 6300 0.38 112.0 0.44 0.57 0.40 0.53 0.57

100LC15/100Z15 100LC19/100Z19
Bridging (kN/m) Bridging (kN/m)
Span Span
L /150 k Inward Outward k Inward Outward
(mm) (mm) L /150
0 1,2 3 0 1 2 3 0 1 2 3 0 1 2 3

2100 12.95 1.1 6.50 6.50 2100 16.34 0.9 8.28 8.74 8.74
2400 8.67 1.8 4.92 4.98 2400 10.95 1.5 6.20 6.69 6.69
2700 6.09 3.0 3.82 3.93 3.93 2700 7.69 2.3 4.79 5.29 5.21
3000 4.44 4.5 3.05 3.19 3.11 3.19 3000 5.60 3.6 3.79 4.28 4.03 4.28
3300 3.34 6.6 2.49 2.63 2.46 2.63 3300 4.21 5.2 3.07 3.54 3.16 3.54
3600 2.57 9.3 2.06 2.21 1.95 2.21 3600 3.24 7.4 2.53 2.97 2.51 2.97
3900 2.02 12.9 1.73 1.89 1.57 1.89 3900 2.55 10.2 2.12 2.53 2.01 2.53
4200 1.62 17.3 1.46 1.63 1.27 1.62 4200 2.04 13.7 1.80 2.18 1.62 2.12 2.18
4500 1.32 22.8 1.25 1.42 1.01 1.37 1.42 4500 1.66 18.1 1.54 1.90 1.30 1.79 1.90
4800 1.08 29.5 1.08 1.25 0.82 1.17 1.25 4800 1.37 23.4 1.33 1.67 1.06 1.51 1.67
5100 0.90 37.6 0.94 1.10 0.67 1.00 1.10 5100 1.14 29.8 1.15 1.48 0.88 1.29 1.48
5400 0.76 47.3 0.83 0.98 0.56 0.85 0.98 5400 0.96 37.5 1.01 1.32 0.73 1.10 1.32
5700 0.65 58.7 0.73 0.88 0.46 0.73 0.88 5700 0.82 46.5 0.89 1.19 0.62 0.94 1.16 1.19
6000 0.56 72.1 0.64 0.80 0.63 0.78 6000 0.70 57.1 0.78 1.07 0.53 0.81 1.02 1.07

6300 0.48 87.5 0.57 0.72 0.54 0.69 0.72 6300 0.61 69.4 0.69 0.96 0.46 0.69 0.90 0.97
6600 0.42 105.5 0.51 0.66 0.46 0.62 0.66 6600 0.53 83.7 0.61 0.86 0.88 0.60 0.80 0.88
6900 0.37 126.0 0.45 0.60 0.55 0.60 6900 0.46 99.8 0.55 0.78 0.81 0.51 0.71 0.80
7200 0.32 149.5 0.40 0.54 0.49 0.55 7200 0.41 118.5 0.49 0.70 0.74 0.45 0.63 0.72
7500 0.28 176.1 0.50 0.51 0.44 0.50 7500 0.36 139.3 0.44 0.64 0.69 0.56 0.65
7800 0.25 205.5 0.45 0.47 0.45 7800 0.32 163.0 0.40 0.58 0.63 0.50 0.59
8100 0.23 238.9 0.41 0.44 0.41 8100 0.29 189.5 0.53 0.57 0.59 0.45 0.54

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

44 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15
10.11

PURLIN & GIRT DESIGN MANUAL


Double Continuous Spans
100LC/100Z span (mm) span (mm)
Limit State Capacity Tables
overall purlin length = 2 x span + 70mm

100LC24/100Z24
Bridging (kN/m)
Span
k Inward Outward
(mm) L /150
0 1 2 3 0 1 2 3

2100 20.54 0.7 10.13 11.12 11.12


2400 13.76 1.2 7.54 8.51 8.51
2700 9.66 1.9 5.81 6.73 6.69
3000 7.04 2.8 4.61 5.45 5.15 5.45
3300 5.29 4.2 3.74 4.50 4.04 4.50
3600 4.08 5.9 3.09 3.78 3.22 3.78
3900 3.21 8.1 2.59 3.22 2.61 3.22
4200 2.57 10.9 2.19 2.78 2.14 2.74
4500 2.09 14.4 1.88 2.42 1.76 2.30 2.42
4800 1.72 18.6 1.63 2.13 1.45 1.95 2.13
5100 1.43 23.7 1.42 1.89 1.21 1.66 1.89
5400 1.21 29.8 1.25 1.68 1.02 1.43 1.68
5700 1.03 37.0 1.10 1.51 0.87 1.24 1.50
6000 0.88 45.5 0.97 1.36 0.75 1.07 1.32 1.36

6300 0.76 55.2 0.86 1.22 0.65 0.94 1.16 1.24


6600 0.66 66.5 0.77 1.10 1.13 0.57 0.82 1.03 1.13
6900 0.58 79.4 0.69 0.99 1.03 0.50 0.71 0.92 1.03
7200 0.51 94.1 0.62 0.89 0.95 0.44 0.62 0.82 0.93
7500 0.45 110.9 0.56 0.81 0.87 0.55 0.73 0.84
7800 0.40 129.7 0.51 0.74 0.81 0.49 0.66 0.76
8100 0.36 150.8 0.47 0.67 0.74 0.43 0.59 0.69
8400 0.32 174.5 0.43 0.61 0.67 0.70 0.54 0.63

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

www.fielders.com.au 45
FINISH ON TOP WITH FIELDERS
10.12

Double Continuous Spans


PURLIN & GIRT DESIGN MANUAL

100FC - Refer details page 7 span (mm) span (mm)


Limit State Capacity Tables
overall purlin length = 2 x span + 70mm

100FC10 100FC12
Bridging (kN/m) Bridging (kN/m)
Span Span
k Inward Outward k Inward Outward
(mm) L /150 (mm) L /150
0 1,2,3 0 1 2,3 0 1,2,3 0 1 2 3

2100 8.87 1.6 4.08 4.08 2100 10.72 1.3 4.95 4.95
2400 5.94 2.7 3.13 3.13 2400 7.18 2.2 3.79 3.79
2700 4.17 4.3 2.47 2.47 2700 5.04 3.6 3.00 3.00
3000 3.04 6.6 2.00 2.00 3000 3.68 5.4 2.43 2.43
3300 2.29 9.6 1.65 1.65 3300 2.76 8.0 2.01 1.99
3600 1.76 13.6 1.39 1.34 1.39 3600 2.13 11.3 1.67 1.58 1.69
3900 1.39 18.8 1.18 1.06 1.18 3900 1.67 15.5 1.40 1.44 1.27 1.44
4200 1.11 25.2 1.02 0.84 1.02 4200 1.34 20.9 1.18 1.24 1.02 1.24
4500 0.90 33.3 0.89 0.67 0.89 4500 1.09 27.5 1.01 1.08 0.82 1.08
4800 0.74 43.1 0.77 0.54 0.78 4800 0.90 35.6 0.88 0.95 0.65 0.95
5100 0.62 54.9 0.67 0.69 0.45 0.68 5100 0.75 45.5 0.76 0.84 0.54 0.81 0.84
5400 0.52 69.0 0.58 0.62 0.58 0.62 5400 0.63 57.1 0.67 0.75 0.45 0.69 0.75
5700 0.44 85.6 0.51 0.55 0.49 0.55 5700 0.54 70.9 0.59 0.67 0.59 0.67
6000 0.38 105.3 0.45 0.50 0.41 0.50 6000 0.46 87.0 0.52 0.61 0.51 0.61

6300 0.33 127.7 0.45 0.45 6300 0.40 105.8 0.46 0.55 0.43 0.55
6600 0.29 153.8 0.41 0.41 6600 0.35 127.5 0.41 0.50 0.50
6900 0.30 152.3 0.46 0.44 0.46
7200 0.27 180.5 0.42 0.42

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

46 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15
10.12

PURLIN & GIRT DESIGN MANUAL


Double Continuous Spans
100FC - Refer details page 7 span (mm) span (mm)
Limit State Capacity Tables
overall purlin length = 2 x span + 70mm

100FC15 100FC19
Bridging (kN/m) Bridging (kN/m)
Span Span
k Inward Outward k Inward Outward
(mm) L /150 (mm) L /150
0 1 2,3 0 1 2 3 0 1 2 3 0 1 2 3

2100 13.49 1.0 6.26 6.40 6.40 2100 17.50 0.8 8.61 8.98 8.98
2400 9.04 1.8 4.71 4.90 4.90 2400 11.73 1.4 6.45 6.88 6.88
2700 6.35 2.8 3.66 3.87 3.87 2700 8.24 2.2 4.98 5.44 5.44
3000 4.63 4.3 2.92 3.14 3.07 3.14 3000 6.00 3.3 3.95 4.40 4.34
3300 3.48 6.3 2.38 2.59 2.44 2.59 3300 4.51 4.9 3.20 3.64 3.46 3.64
3600 2.68 9.0 1.97 2.18 1.97 2.18 3600 3.47 6.9 2.64 3.06 2.78 3.06
3900 2.11 12.3 1.66 1.86 1.61 1.86 3900 2.73 9.5 2.21 2.61 2.25 2.61
4200 1.69 16.6 1.41 1.60 1.33 1.60 4200 2.19 12.8 1.88 2.25 1.85 2.25
4500 1.37 21.9 1.22 1.39 1.10 1.36 1.39 4500 1.78 16.9 1.61 1.96 1.53 1.94
4800 1.13 28.3 1.05 1.23 0.91 1.16 1.23 4800 1.47 21.8 1.40 1.72 1.26 1.66 1.72
5100 0.94 36.1 0.92 1.09 0.77 1.00 1.09 5100 1.22 27.8 1.22 1.52 1.05 1.43 1.52
5400 0.79 45.4 0.81 0.97 0.64 0.87 0.97 5400 1.03 35.0 1.07 1.36 0.89 1.23 1.36
5700 0.68 56.3 0.72 0.87 0.54 0.76 0.87 5700 0.88 43.4 0.94 1.22 0.75 1.06 1.22
6000 0.58 69.2 0.64 0.78 0.46 0.66 0.78 6000 0.75 53.3 0.83 1.10 0.64 0.93 1.10

6300 0.50 84.0 0.57 0.71 0.58 0.69 0.71 6300 0.65 64.8 0.74 1.00 0.55 0.81 0.98
6600 0.44 101.1 0.51 0.65 0.51 0.62 0.65 6600 0.56 78.0 0.66 0.91 0.47 0.71 0.88 0.91
6900 0.38 121.1 0.46 0.59 0.44 0.55 0.59 6900 0.49 93.3 0.59 0.82 0.41 0.62 0.79 0.83
7200 0.34 143.3 0.41 0.53 0.55 0.50 0.54 7200 0.43 110.6 0.54 0.75 0.76 0.54 0.70 0.76
7500 0.30 168.9 0.49 0.50 0.45 0.50 7500 0.38 130.2 0.48 0.68 0.70 0.48 0.63 0.70
7800 0.26 197.7 0.44 0.46 0.40 0.45 7800 0.34 152.0 0.44 0.62 0.65 0.42 0.57 0.64
8100 0.24 229.8 0.41 0.43 0.41 8100 0.31 177.0 0.40 0.57 0.60 0.51 0.59
8400 0.27 205.1 0.52 0.56 0.46 0.54
8700 0.25 235.8 0.48 0.52 0.42 0.49
9000 0.22 270.3 0.44 0.48 0.49 0.45

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

www.fielders.com.au 47
FINISH ON TOP WITH FIELDERS
10.13

Double Continuous Spans


PURLIN & GIRT DESIGN MANUAL

150LC/150Z span (mm) span (mm)


Limit State Capacity Tables
overall purlin length = 2 x span + 70mm

150LC12/150Z12 150LC15/150Z15
Bridging (kN/m) Bridging (kN/m)
Span Span
k Inward Outward k Inward Outward
(mm) L /150 (mm) L /150
0 1,2,3 0 1 2,3 0 1,2,3 0 1 2,3

2400 21.35 0.7 5.45 6.56 2400 27.21 0.6 8.42 8.42
2700 15.00 1.2 4.59 5.45 2700 19.11 0.9 6.92 6.92
3000 10.93 1.8 3.92 3.92 3000 13.93 1.4 5.68 5.78
3300 8.21 2.7 3.38 3.38 3300 10.47 2.1 4.59 4.78 4.78
3600 6.33 3.8 2.94 2.94 3600 8.06 3.0 3.79 4.02 4.02
3900 4.98 5.2 2.58 2.58 3900 6.34 4.1 3.17 3.42 3.42
4200 3.98 7.0 2.28 2.28 4200 5.08 5.5 2.69 2.95 2.95
4500 3.24 9.3 1.97 2.02 2.02 4500 4.13 7.3 2.30 2.57 2.49 2.57
4800 2.67 12.0 1.71 1.77 1.72 1.77 4800 3.40 9.4 1.99 2.26 2.10 2.26
5100 2.23 15.3 1.50 1.57 1.45 1.57 5100 2.84 12.0 1.74 2.00 1.78 2.00
5400 1.87 19.2 1.32 1.40 1.21 1.40 5400 2.39 15.1 1.52 1.79 1.49 1.79
5700 1.59 23.8 1.16 1.26 1.02 1.26 5700 2.03 18.7 1.34 1.60 1.25 1.60
6000 1.37 29.3 1.02 1.14 0.86 1.14 6000 1.74 23.0 1.18 1.45 1.06 1.45

6300 1.18 35.6 0.91 1.03 0.74 1.03 6300 1.51 27.9 1.05 1.31 0.92 1.31
6600 1.03 42.8 0.81 0.94 0.63 0.94 6600 1.31 33.6 0.94 1.20 0.80 1.17 1.20
6900 0.90 51.2 0.73 0.86 0.55 0.84 6900 1.15 40.2 0.84 1.09 0.70 1.04 1.09
7200 0.79 60.7 0.66 0.79 0.48 0.76 0.79 7200 1.01 47.6 0.76 1.00 0.62 0.92 1.00
7500 0.70 71.4 0.59 0.73 0.42 0.67 0.73 7500 0.89 56.1 0.68 0.93 0.54 0.82 0.93
7800 0.62 83.6 0.54 0.67 0.59 0.67 7800 0.79 65.6 0.62 0.86 0.47 0.73 0.86
8100 0.56 97.3 0.49 0.62 0.52 0.62 8100 0.71 76.3 0.56 0.79 0.41 0.65 0.79
8400 0.50 112.4 0.45 0.58 0.46 0.58 8400 0.64 88.2 0.52 0.74 0.57 0.74
8700 0.45 129.5 0.41 0.54 0.41 0.54 8700 0.57 101.6 0.47 0.69 0.51 0.69

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

48 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15
10.13

PURLIN & GIRT DESIGN MANUAL


Double Continuous Spans
150LC/150Z span (mm) span (mm)
Limit State Capacity Tables
overall purlin length = 2 x span + 70mm

150LC19/150Z19 150LC24/150Z24
Bridging (kN/m) Bridging (kN/m)
Span Span
(mm) L /150 k Inward Outward (mm) L /150 k Inward Outward
0 1 2,3 0 1 2 3 0 1 2,3 0 1 2 3

2400 34.36 0.5 11.56 12.06 12.06


2700 24.13 0.7 8.89 9.71 9.71 2700 30.92 0.6 11.58 13.34 13.34
3000 17.59 1.1 7.04 7.95 7.95 3000 22.55 0.9 9.05 10.81 10.81
3300 13.22 1.7 5.70 6.57 6.57 3300 16.94 1.3 7.25 8.93 8.93
3600 10.18 2.4 4.70 5.52 5.52 3600 13.05 1.8 5.89 7.50 7.50
3900 8.01 3.2 3.94 4.71 4.56 4.71 3900 10.26 2.5 4.85 6.39 6.25 6.39
4200 6.41 4.4 3.33 4.06 3.81 4.06 4200 8.22 3.4 4.07 5.51 5.22 5.51
4500 5.21 5.8 2.84 3.53 3.21 3.53 4500 6.68 4.5 3.46 4.80 4.35 4.80
4800 4.30 7.5 2.45 3.11 2.73 3.11 4800 5.50 5.8 2.97 4.22 3.66 4.22
5100 3.58 9.5 2.14 2.75 2.33 2.75 5100 4.59 7.4 2.58 3.74 3.10 3.74
5400 3.02 11.9 1.87 2.45 1.99 2.45 5400 3.87 9.3 2.26 3.34 2.63 3.34
5700 2.57 14.8 1.66 2.20 1.70 2.17 5700 3.29 11.6 1.99 2.99 2.22 2.98
6000 2.20 18.2 1.47 1.99 1.46 1.91 1.99 6000 2.82 14.2 1.76 2.70 1.90 2.63 2.70

6300 1.90 22.1 1.31 1.80 1.25 1.70 1.80 6300 2.43 17.3 1.57 2.45 1.63 2.33 2.45
6600 1.65 26.6 1.17 1.64 1.08 1.51 1.64 6600 2.12 20.8 1.40 2.23 1.40 2.07 2.23
6900 1.45 31.8 1.05 1.50 0.93 1.35 1.50 6900 1.85 24.8 1.26 2.04 1.21 1.83 2.04
7200 1.27 37.7 0.95 1.38 0.80 1.21 1.38 7200 1.63 29.4 1.14 1.88 1.06 1.63 1.88
7500 1.13 44.4 0.86 1.27 0.70 1.09 1.27 7500 1.44 34.7 1.03 1.72 0.93 1.46 1.73
7800 1.00 51.9 0.78 1.17 0.61 0.98 1.16 7800 1.28 40.5 0.94 1.58 0.82 1.31 1.60
8100 0.89 60.4 0.71 1.07 0.54 0.88 1.06 1.09 8100 1.15 47.2 0.86 1.45 1.48 0.72 1.16 1.46
8400 0.80 69.9 0.65 0.99 1.01 0.48 0.79 0.97 1.01 8400 1.03 54.5 0.78 1.33 1.38 0.64 1.04 1.33 1.38
8700 0.72 80.4 0.60 0.91 0.95 0.43 0.71 0.89 0.95 8700 0.92 62.8 0.72 1.23 1.29 0.57 0.93 1.22 1.29
9000 0.65 92.0 0.55 0.84 0.88 0.63 0.82 0.88 9000 0.84 71.9 0.66 1.14 1.20 0.52 0.83 1.12 1.20

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

www.fielders.com.au 49
FINISH ON TOP WITH FIELDERS
10.14

Double Continuous Spans


PURLIN & GIRT DESIGN MANUAL

200LC/200Z span (mm) span (mm)


Limit State Capacity Tables
overall purlin length = 2 x span + 70mm

200LC15/200Z15 200LC19/200Z19
Bridging (kN/m) Bridging (kN/m)
Span Span
k Inward Outward k Inward Outward
(mm) L /150 (mm) L /150
0 1,2,3 0 1 2,3 0 1,2,3 0 1 2,3

3000 29.31 0.7 6.20 6.20 3300 29.34 0.7 8.97 9.25 9.25
3300 22.02 1.0 5.39 5.39 3600 22.60 1.1 7.31 8.01 8.01
3600 16.96 1.4 4.73 4.73 3900 17.78 1.5 6.00 6.98 6.98
3900 13.34 1.9 4.18 4.18 4200 14.24 2.0 4.95 6.02 6.02
4200 10.68 2.6 3.72 3.72 4500 11.57 2.6 4.12 5.24 5.24
4500 8.68 3.5 3.33 3.33 4800 9.53 3.4 3.54 4.61 4.61
4800 7.16 4.5 2.88 2.99 2.99 5100 7.95 4.3 3.07 4.08 4.08
5100 5.97 5.7 2.51 2.70 2.70 5400 6.70 5.4 2.69 3.64 3.51 3.64
5400 5.03 7.2 2.19 2.44 2.44 5700 5.69 6.7 2.37 3.27 3.03 3.27
5700 4.27 8.9 1.93 2.19 2.14 2.19 6000 4.88 8.2 2.11 2.95 2.63 2.95
6000 3.66 10.9 1.71 1.98 1.87 1.98
6300 4.22 10.0 1.88 2.68 2.26 2.68
6300 3.17 13.3 1.52 1.79 1.62 1.79 6600 3.67 12.0 1.69 2.44 1.90 2.44
6600 2.75 16.0 1.36 1.64 1.40 1.64 6900 3.21 14.3 1.53 2.23 1.67 2.23
6900 2.41 19.1 1.224 1.496 1.21 1.50 7200 2.83 17.0 1.38 2.05 1.47 2.05
7200 2.12 22.6 1.105 1.374 1.05 1.37 7500 2.50 20.0 1.26 1.89 1.30 1.89
7500 1.88 26.7 1.002 1.266 0.92 1.27 7800 2.22 23.4 1.15 1.75 1.16 1.73
7800 1.67 31.2 0.911 1.171 0.81 1.17 8100 1.98 27.2 1.05 1.62 1.03 1.56 1.62
8100 1.49 36.3 0.832 1.085 0.72 1.08 8400 1.78 31.5 0.97 1.50 0.92 1.41 1.50
8400 1.34 41.9 0.761 1.009 0.64 0.99 1.01 8700 1.60 36.2 0.89 1.40 0.82 1.28 1.40
8700 1.20 48.3 0.699 0.941 0.57 0.90 0.94 9000 1.45 41.5 0.83 1.31 0.73 1.17 1.31
9000 1.09 55.3 0.643 0.879 0.49 0.82 0.88

200LC24/200Z24
Bridging (kN/m)
Span
k Inward Outward
(mm) L /150
0 1 2,3 0 1 2,3

3900 22.45 1.2 7.58 9.77 9.77


4200 17.98 1.6 6.28 8.43 8.42
4500 14.61 2.1 5.28 7.34 7.29
4800 12.04 2.7 4.50 6.45 6.22 6.45
5100 10.04 3.4 3.88 5.71 5.35 5.71
5400 8.46 4.3 3.38 5.10 4.63 5.10
5700 7.19 5.3 2.96 4.57 4.03 4.57
6000 6.17 6.5 2.62 4.13 3.53 4.13

6300 5.33 7.9 2.34 3.74 3.07 3.74


6600 4.63 9.5 2.09 3.41 2.66 3.41
6900 4.05 11.3 1.88 3.12 2.31 3.10
7200 3.57 13.5 1.70 2.87 2.01 2.79 2.87
7500 3.16 15.8 1.54 2.64 1.76 2.52 2.64
7800 2.81 18.5 1.40 2.44 1.56 2.28 2.44
8100 2.51 21.5 1.27 2.26 1.38 2.07 2.27
8400 2.25 24.9 1.17 2.08 1.22 1.89 2.11
8700 2.02 28.7 1.07 1.92 1.96 1.09 1.72 1.96
9000 1.83 32.8 0.99 1.78 1.84 0.97 1.57 1.84

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

50 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15

PURLIN & GIRT DESIGN MANUAL


This page intentionally blank

www.fielders.com.au 51
FINISH ON TOP WITH FIELDERS
10.15

Double Continuous Spans


PURLIN & GIRT DESIGN MANUAL

250LC/250Z span (mm) span (mm)


Limit State Capacity Tables
overall purlin length = 2 x span + 70mm

250LC19/250Z19 250LC24/250Z24
Bridging (kN/m) Bridging (kN/m)
Span Span
k Inward Outward k Inward Outward
(mm) L /150 (mm) L /150
0 1,2,3 0 1 2,3 0 1,2,3 0 1 2,3

3600 36.82 0.7 8.16 8.16


3900 28.96 0.9 7.25 7.25
4200 23.19 1.2 6.15 6.48 6.48
4500 18.85 1.6 5.21 5.83 5.83
4800 15.53 2.1 4.46 5.26 5.26 4800 19.94 1.6 5.54 8.15 8.15
5100 12.95 2.6 3.87 4.77 4.77 5100 16.63 2.0 4.75 7.22 7.02 7.22
5400 10.91 3.3 3.38 4.35 4.35 5400 14.01 2.6 4.12 6.44 6.01 6.44
5700 9.28 4.1 2.98 3.97 3.84 3.97 5700 11.91 3.2 3.60 5.78 5.10 5.78
6000 7.95 5.0 2.64 3.60 3.29 3.60 6000 10.21 3.9 3.17 5.22 4.32 5.22

6300 6.87 6.1 2.35 3.27 2.84 3.27 6300 8.82 4.8 2.81 4.73 3.70 4.73
6600 5.98 7.4 2.11 2.98 2.44 2.98 6600 7.67 5.7 2.51 4.31 3.19 4.31
6900 5.23 8.8 1.90 2.73 2.12 2.73 6900 6.71 6.9 2.25 3.94 2.74 3.94
7200 4.60 10.4 1.72 2.50 1.86 2.50 7200 5.91 8.1 2.02 3.62 2.36 3.62
7500 4.07 12.3 1.57 2.31 1.64 2.31 7500 5.23 9.6 1.83 3.34 2.05 3.30
7800 3.62 14.4 1.43 2.13 1.43 2.13 7800 4.65 11.2 1.66 3.09 1.79 2.98 3.09
8100 3.23 16.7 1.31 1.98 1.25 1.98 8100 4.15 13.0 1.52 2.86 1.57 2.68 2.86
8400 2.90 19.3 1.20 1.84 1.10 1.79 1.84 8400 3.72 15.0 1.39 2.66 1.38 2.41 2.66
8700 2.61 22.2 1.11 1.71 0.97 1.61 1.71 8700 3.35 17.3 1.27 2.48 1.22 2.15 2.48
9000 2.36 25.5 1.02 1.60 0.86 1.45 1.60 9000 3.03 19.8 1.17 2.32 1.09 1.92 2.32

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

52 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15
10.16

Double Continuous Spans

PURLIN & GIRT DESIGN MANUAL


300LC span (mm) span (mm)
Limit State Capacity Tables
overall purlin length = 2 x span + 70mm

300LC24 300LC30
Bridging (kN/m) Bridging (kN/m)
Span Span
k Inward Outward k Inward Outward
(mm) L /150 (mm) L /150
0 1,2,3 0 1,2,3 0 1,2,3 0 1,2,3

3600 107.63 0.2 24.37 24.37


3900 65.87 0.4 13.19 13.19 3900 84.65 0.3 19.68 21.47 21.47
4200 52.74 0.5 11.86 11.86 4200 67.78 0.4 15.94 19.05 19.05
4500 42.88 0.7 9.86 10.71 10.71 4500 55.11 0.5 13.03 17.00 17.00
4800 35.33 0.9 8.37 9.72 9.72 4800 45.41 0.7 10.81 15.25 15.25
5100 29.46 1.2 7.19 8.86 8.85 5100 37.86 0.9 9.09 13.75 13.75
5400 24.81 1.5 6.24 8.10 8.10 5400 31.89 1.1 7.74 12.46 12.46
5700 21.10 1.8 5.47 7.43 7.43 5700 27.12 1.4 6.66 11.33 11.33
6000 18.09 2.2 4.82 6.84 6.84
6000 23.25 1.7 5.79 10.35 10.35
6300 15.63 2.7 4.26 6.31 6.31 6300 20.08 2.1 5.07 9.45 9.25 9.45
6600 13.59 3.2 3.79 5.84 5.84 6600 17.47 2.5 4.47 8.61 8.23 8.61
6900 11.89 3.9 3.39 5.42 5.40 6900 15.29 3.0 3.98 7.88 7.36 7.88
7200 10.47 4.6 3.05 5.04 4.81 5.04 7200 13.45 3.6 3.55 7.23 6.60 7.23
7500 9.26 5.4 2.75 4.66 4.28 4.66 7500 11.90 4.2 3.19 6.67 5.94 6.67
7800 8.23 6.3 2.50 4.31 3.77 4.31 7800 10.58 4.9 2.89 6.16 5.31 6.16
8100 7.35 7.3 2.27 4.00 3.34 4.00 8100 9.45 5.7 2.62 5.72 4.71 5.72
8400 6.59 8.5 2.07 3.72 2.92 3.72 8400 8.47 6.6 2.39 5.32 4.20 5.32
8700 5.93 9.8 1.89 3.47 2.63 3.47 8700 7.63 7.6 2.18 4.96 3.75 4.96
9000 5.36 11.2 1.74 3.24 2.38 3.24 9000 6.89 8.7 2.00 4.63 3.33 4.63

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

www.fielders.com.au 53
FINISH ON TOP WITH FIELDERS
10.17

Double Continuous Spans


PURLIN & GIRT DESIGN MANUAL

350LC span (mm) span (mm)


Limit State Capacity Tables
overall purlin length = 2 x span + 70mm

350LC30
Bridging (kN/m)
Span
k Inward Outward
(mm) L /150
0 1,2,3 0 1,2,3

3300 228.3 0.1 28.05 28.05


3600 175.9 0.1 24.97 24.97
3900 138.3 0.2 22.38 22.38
4200 110.7 0.3 20.16 20.16
4500 90.04 0.3 18.25 18.25
4800 74.19 0.4 15.65 16.59 16.59
5100 61.86 0.5 13.14 15.14 15.14
5400 52.11 0.7 11.15 13.86 13.86
5700 44.31 0.9 9.39 12.74 12.74
6000 37.99 1.1 8.20 11.74 11.74

6300 32.81 1.3 7.22 10.85 10.85


6600 28.54 1.5 6.40 10.06 10.05
6900 24.98 1.8 5.70 9.34 9.34
7200 21.98 2.2 5.12 8.70 8.70
7500 19.45 2.6 4.59 8.12 8.12
7800 17.29 3.0 4.13 7.55 7.55
8100 15.44 3.5 3.73 7.00 7.00
8400 13.84 4.0 3.39 6.51 6.51
8700 12.46 4.7 3.09 6.07 5.94 6.07
9000 11.26 5.3 2.83 5.67 5.41 5.67

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

54 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15
10.18

Double Continuous Spans

PURLIN & GIRT DESIGN MANUAL


400LC span (mm) span (mm)
Limit State Capacity Tables
overall purlin length = 2 x span + 70mm

400LC30
Bridging (kN/m)
Span
k Inward Outward
(mm) L /150
0 1,2,3 0 1,2,3

4500 110.92 0.3 17.74 17.74


4800 91.40 0.4 15.25 16.26 16.27
5100 76.20 0.4 12.77 14.97 14.97
5400 64.19 0.6 10.82 13.82 13.82
5700 54.58 0.7 9.28 12.79 12.79
6000 46.79 0.9 8.03 11.87 11.88

6300 40.42 1.0 7.01 11.05 11.05


6600 35.16 1.3 6.16 10.30 10.31
6900 30.77 1.5 5.46 9.63 9.63
7200 27.08 1.8 4.87 9.02 9.02
7500 23.96 2.1 4.36 8.46 8.46
7800 21.30 2.4 3.93 7.95 7.95
8100 19.02 2.8 3.56 7.48 7.10 7.48
8400 17.05 3.3 3.24 7.05 6.26 7.05
8700 15.35 3.8 2.95 6.66 5.53 6.66
9000 13.87 4.3 2.71 6.30 4.91 6.30

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

www.fielders.com.au 55
FINISH ON TOP WITH FIELDERS
10.19

Double Lapped Spans lap


PURLIN & GIRT DESIGN MANUAL

100Z
Limit State Capacity Tables span (mm) span (mm)
overall purlin length =
span + 70mm + (lap/2)

100Z10 100Z12
Bridging (kN/m) Bridging (kN/m)
Span Span
k Inward Outward k Inward Outward
(mm) L /150 (mm) L /150
0 1 2,3 0 1 2 3 0 1 2 3 0 1 2 3

2100 9.13 1.5 4.77 4.77 2100 11.58 1.2 6.65 6.83 6.83
2400 6.12 2.6 3.87 3.87 2400 7.76 2.1 4.82 5.27 5.27
2700 4.30 4.2 3.19 3.19 2700 5.45 3.3 3.74 4.16 4.06 4.16
3000 3.13 6.4 2.59 2.50 2.61 3000 3.97 5.0 2.97 3.37 3.01 3.37
3300 2.35 9.3 2.09 2.16 1.90 2.16 3300 2.98 7.4 2.41 2.79 2.35 2.79
3600 1.81 13.2 1.72 1.81 1.44 1.81 3600 2.30 10.4 1.99 2.34 1.83 2.34
3900 1.43 18.2 1.43 1.54 1.11 1.54 3900 1.81 14.4 1.67 2.00 1.44 2.00
4200 1.14 24.5 1.20 1.33 0.87 1.33 4200 1.45 19.3 1.40 1.72 1.16 1.65 1.72
4500 0.93 32.3 1.01 1.16 0.69 1.11 1.16 4500 1.18 25.5 1.19 1.50 0.93 1.34 1.50
4800 0.77 41.8 0.86 1.02 0.56 0.92 1.02 4800 0.97 33.0 1.02 1.32 0.75 1.13 1.32
5100 0.64 53.3 0.74 0.90 0.47 0.76 0.90 5100 0.81 42.0 0.88 1.17 0.61 0.96 1.17
5400 0.54 67.0 0.64 0.81 0.63 0.81 5400 0.68 52.9 0.77 1.04 0.50 0.81 1.01 1.04
5700 0.46 83.2 0.55 0.72 0.52 0.71 5700 0.58 65.6 0.67 0.93 0.41 0.68 0.85 0.93
6000 0.39 102.0 0.48 0.65 0.44 0.62 0.65 6000 0.50 80.5 0.59 0.82 0.84 0.59 0.75 0.84
6300 0.34 124.3 0.42 0.59 0.53 0.59 6300 0.43 97.9 0.53 0.73 0.77 0.50 0.66 0.77
6600 0.29 149.7 0.54 0.46 0.54 6600 0.37 118.0 0.47 0.64 0.70 0.43 0.58 0.68
6900 0.26 179.0 0.48 0.49 0.49 6900 0.33 141.1 0.42 0.57 0.64 0.51 0.61
7200 0.23 211.5 0.43 0.45 0.44 7200 0.29 167.2 0.51 0.59 0.44 0.53
7500 0.25 196.9 0.47 0.53 0.54 0.48
7800 0.23 230.1 0.42 0.48 0.50 0.43

100Z24
Bridging (kN/m)
Span
k Inward Outward
(mm) L /150
0 1 2 3 0 1 2 3

2100 23.49 0.6 12.32 15.11 15.11


2400 15.74 1.0 9.10 11.60 11.60
2700 11.05 1.6 6.98 9.17 8.65 9.17
3000 8.06 2.5 5.48 7.43 6.59 7.43
3300 6.05 3.6 4.39 6.14 5.12 6.14
3600 4.66 5.1 3.59 5.16 4.05 5.16
3900 3.67 7.1 2.98 4.39 3.23 4.33
4200 2.94 9.5 2.51 3.79 2.56 3.58 3.79
4500 2.39 12.6 2.14 3.26 2.07 2.99 3.30
4800 1.97 16.3 1.84 2.82 2.90 1.70 2.52 2.90
5100 1.64 20.7 1.60 2.45 2.57 1.41 2.14 2.55
5400 1.38 26.0 1.40 2.15 2.29 1.19 1.83 2.20 2.29
5700 1.18 32.3 1.23 1.90 2.06 1.01 1.57 1.92 2.06
6000 1.01 39.7 1.09 1.68 1.86 0.86 1.35 1.68 1.86
6300 0.87 48.3 0.97 1.50 1.68 0.75 1.15 1.47 1.67
6600 0.76 58.1 0.87 1.34 1.53 0.65 0.99 1.30 1.49
6900 0.66 69.5 0.78 1.21 1.39 0.57 0.86 1.15 1.32
7200 0.58 82.3 0.70 1.09 1.25 1.29 0.51 0.75 1.02 1.19
7500 0.52 96.9 0.64 0.99 1.14 1.19 0.45 0.66 0.91 1.06
7800 0.46 113.5 0.58 0.90 1.03 1.10 0.40 0.58 0.80 0.96
8100 0.41 132.0 0.53 0.82 0.94 1.02 0.52 0.71 0.86
8400 0.37 152.6 0.48 0.75 0.86 0.94 0.46 0.63 0.78
8700 0.33 175.8 0.44 0.68 0.78 0.87 0.41 0.56 0.71
9000 0.30 201.3 0.41 0.63 0.72 0.80 0.51 0.64
9300 0.27 229.6 0.57 0.66 0.73 0.45 0.59
9600 0.25 260.2 0.52 0.61 0.68 0.41 0.53

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

56 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15
10.19

lap

PURLIN & GIRT DESIGN MANUAL


Double Lapped Spans
100Z
Limit State Capacity Tables span (mm) span (mm)
overall purlin length =
span + 70mm + (lap/2)

100Z15 100Z19
Bridging (kN/m) Bridging (kN/m)
Span Span
k Inward Outward k Inward Outward
(mm) L /150 (mm) L /150
0 1 2 3 0 1 2 3 0 1 2 3 0 1 2 3

2100 14.77 0.9 8.25 8.82 8.82 2100 18.67 0.8 10.17 11.84 11.84
2400 9.90 1.6 6.17 6.75 6.75 2400 12.50 1.3 7.53 9.07 9.02
2700 6.95 2.6 4.76 5.34 5.20 5.34 2700 8.78 2.0 5.78 7.17 6.76 7.17
3000 5.07 3.9 3.77 4.32 4.03 4.32 3000 6.40 3.1 4.56 5.81 5.18 5.81
3300 3.81 5.8 3.05 3.57 3.13 3.57 3300 4.81 4.6 3.68 4.80 4.01 4.80
3600 2.93 8.2 2.51 3.00 2.47 3.00 3600 3.71 6.5 3.00 4.03 3.14 4.03
3900 2.31 11.3 2.10 2.56 1.94 2.55 3900 2.91 8.9 2.48 3.44 2.45 3.35 3.44
4200 1.85 15.2 1.77 2.21 1.51 2.13 2.21 4200 2.33 12.0 2.08 2.96 1.93 2.78 2.96
4500 1.50 20.0 1.50 1.92 1.20 1.80 1.92 4500 1.90 15.8 1.76 2.58 1.54 2.34 2.58
4800 1.24 25.9 1.29 1.69 0.97 1.52 1.69 4800 1.56 20.5 1.51 2.23 1.25 1.96 2.27
5100 1.03 33.0 1.11 1.50 0.79 1.29 1.50 5100 1.30 26.1 1.30 1.94 2.01 1.03 1.66 1.97 2.01
5400 0.87 41.4 0.96 1.32 0.65 1.10 1.31 1.33 5400 1.10 32.8 1.13 1.71 1.79 0.86 1.41 1.71 1.79
5700 0.74 51.4 0.83 1.17 1.20 0.54 0.93 1.14 1.20 5700 0.93 40.7 0.99 1.51 1.61 0.72 1.19 1.49 1.61
6000 0.63 63.2 0.73 1.04 1.08 0.46 0.78 1.01 1.08 6000 0.80 50.0 0.88 1.34 1.45 0.62 1.00 1.31 1.45
6300 0.55 76.8 0.64 0.93 0.98 0.66 0.88 0.98 6300 0.69 60.8 0.77 1.20 1.32 0.53 0.85 1.14 1.29
6600 0.48 92.4 0.57 0.84 0.89 0.56 0.78 0.88 6600 0.60 73.2 0.69 1.07 1.20 0.46 0.73 1.00 1.15
6900 0.42 110.6 0.51 0.75 0.82 0.48 0.69 0.79 6900 0.53 87.5 0.62 0.96 1.08 1.10 0.63 0.88 1.03
7200 0.37 130.8 0.45 0.68 0.74 0.42 0.61 0.71 7200 0.46 103.7 0.55 0.86 0.97 1.01 0.55 0.78 0.92
7500 0.32 154.3 0.40 0.61 0.68 0.69 0.53 0.64 7500 0.41 122.0 0.50 0.78 0.88 0.93 0.48 0.68 0.83
7800 0.29 180.6 0.56 0.62 0.64 0.47 0.58 7800 0.36 142.9 0.45 0.70 0.80 0.86 0.42 0.60 0.74
8100 0.26 210.1 0.50 0.56 0.59 0.41 0.52 8100 0.33 166.2 0.41 0.64 0.73 0.79 0.53 0.67
8400 0.23 242.4 0.46 0.52 0.55 0.47 8400 0.29 191.8 0.58 0.67 0.73 0.47 0.60
8700 0.21 278.8 0.42 0.47 0.51 0.42 8700 0.26 220.5 0.53 0.61 0.67 0.41 0.54

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

www.fielders.com.au 57
FINISH ON TOP WITH FIELDERS
10.20

Double Lapped Spans lap


PURLIN & GIRT DESIGN MANUAL

150Z
Limit State Capacity Tables span (mm) span (mm)
overall purlin length =
span + 70mm + (lap/2)

150Z12 150Z15
Bridging (kN/m) Bridging (kN/m)
Span Span
k Inward Outward k Inward Outward
(mm) L /150 (mm) L /150
0 1 2,3 0 1 2 3 0 1 2 3 0 1 2 3

3000 12.41 1.6 4.83 4.83 3000 15.82 1.3 6.92 7.40 7.40
3300 9.32 2.4 4.21 4.21 3300 11.89 1.9 5.53 6.31 6.31
3600 7.18 3.3 3.70 3.70 3600 9.15 2.6 4.49 5.44 5.44
3900 5.65 4.6 3.27 3.27 3900 7.20 3.6 3.66 4.70 4.60 4.70
4200 4.52 6.2 2.75 2.91 2.91 4200 5.77 4.9 3.09 4.06 3.79 4.06
4500 3.68 8.2 2.34 2.60 2.59 4500 4.69 6.4 2.64 3.53 3.14 3.53
4800 3.03 10.6 2.01 2.34 2.12 2.34 4800 3.86 8.3 2.28 3.11 2.61 3.11
5100 2.53 13.5 1.74 2.12 1.75 2.12 5100 3.22 10.6 1.98 2.75 2.12 2.75
5400 2.13 16.9 1.52 1.92 1.45 1.92 5400 2.71 13.3 1.74 2.45 1.80 2.45
5700 1.81 21.0 1.33 1.73 1.22 1.73 5700 2.31 16.5 1.54 2.20 1.53 2.20
6000 1.55 25.8 1.18 1.56 1.03 1.56 6000 1.98 20.2 1.37 1.99 1.32 1.94 1.99
6300 1.34 31.3 1.05 1.42 0.88 1.40 6300 1.71 24.6 1.22 1.80 1.13 1.71 1.80
6600 1.17 37.8 0.94 1.29 0.75 1.24 1.29 6600 1.49 29.6 1.10 1.64 0.97 1.51 1.64
6900 1.02 45.1 0.84 1.18 0.65 1.09 1.18 6900 1.30 35.4 0.99 1.50 0.83 1.33 1.50
7200 0.90 53.5 0.76 1.09 0.57 0.95 1.09 7200 1.14 42.0 0.90 1.38 0.72 1.18 1.38
7500 0.79 63.0 0.68 1.00 0.50 0.83 1.00 7500 1.01 49.4 0.81 1.26 0.62 1.03 1.27
7800 0.71 73.7 0.62 0.93 0.44 0.73 0.93 7800 0.90 57.8 0.74 1.15 1.18 0.54 0.90 1.16
8100 0.63 85.7 0.56 0.86 0.64 0.86 8100 0.80 67.2 0.67 1.05 1.09 0.47 0.80 1.05 1.09
8400 0.57 99.1 0.51 0.80 0.57 0.79 8400 0.72 77.7 0.62 0.96 1.01 0.42 0.72 0.95 1.01
8700 0.51 113.9 0.47 0.74 0.51 0.71 0.74 8700 0.65 89.4 0.56 0.88 0.95 0.65 0.87 0.95
9000 0.46 130.4 0.43 0.69 0.45 0.65 0.70 9000 0.59 102.4 0.52 0.81 0.88 0.59 0.79 0.88
9300 0.42 148.7 0.64 0.65 0.41 0.58 0.65 9300 0.53 116.8 0.47 0.75 0.83 0.53 0.72 0.83
9600 0.38 168.9 0.59 0.61 0.52 0.61 9600 0.48 132.5 0.43 0.69 0.78 0.48 0.65 0.77
9900 0.35 191.3 0.54 0.57 0.47 0.57 9900 0.44 150.0 0.40 0.64 0.73 0.43 0.59 0.71
10200 0.32 215.2 0.50 0.54 0.43 0.54 10200 0.40 169.2 0.60 0.69 0.53 0.66
10500 0.29 242.2 0.46 0.51 0.50 10500 0.37 189.7 0.55 0.64 0.48 0.61
10800 0.27 270.7 0.42 0.48 0.46 10800 0.34 212.4 0.51 0.60 0.61 0.44 0.56
11100 0.25 302.0 0.46 0.43 11100 0.31 237.2 0.47 0.56 0.58 0.41 0.52
11400 0.29 263.9 0.43 0.52 0.55 0.48
11700 0.27 292.1 0.40 0.49 0.52 0.45
12000 0.25 323.9 0.46 0.50 0.41

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

58 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15
10.20

lap

PURLIN & GIRT DESIGN MANUAL


Double Lapped Spans
150Z
Limit State Capacity Tables span (mm) span (mm)
overall purlin length =
span + 70mm + (lap/2)

150Z19 150Z24
Bridging (kN/m) Bridging (kN/m)
Span Span
k Inward Outward k Inward Outward
(mm) L /150 (mm) L /150
0 1 2 3 0 1 2 3 0 1 2 3 0 1 2 3

3000 19.97 1.0 8.67 10.65 10.65 3000 25.81 0.8 10.44 15.05 15.05
3300 15.01 1.5 6.85 8.93 8.93 3300 19.39 1.1 8.17 12.44 12.44
3600 11.56 2.1 5.55 7.59 7.28 7.59 3600 14.94 1.6 6.56 10.45 10.01 10.45
3900 9.09 2.9 4.58 6.46 5.99 6.46 3900 11.75 2.2 5.38 8.91 8.15 8.91
4200 7.28 3.8 3.84 5.57 4.97 5.57 4200 9.41 3.0 4.48 7.68 6.72 7.68
4500 5.92 5.1 3.26 4.85 4.17 4.86 4500 7.65 3.9 3.79 6.69 5.59 6.69
4800 4.88 6.6 2.80 4.27 3.50 4.27 4800 6.30 5.1 3.24 5.88 4.66 5.88
5100 4.07 8.4 2.42 3.78 2.91 3.78 5100 5.25 6.5 2.80 5.19 3.81 5.21
5400 3.43 10.5 2.11 3.35 2.43 3.29 3.37 5400 4.43 8.1 2.44 4.55 4.65 3.16 4.56
5700 2.91 13.0 1.85 2.97 2.05 2.88 3.03 5700 3.76 10.1 2.15 4.02 4.17 2.64 3.97 4.17
6000 2.50 16.0 1.63 2.65 2.73 1.73 2.54 2.73 6000 3.23 12.4 1.90 3.57 3.76 2.22 3.48 3.76
6300 2.16 19.5 1.45 2.38 2.48 1.46 2.24 2.48 6300 2.79 15.1 1.69 3.19 3.41 1.89 3.06 3.41
6600 1.88 23.5 1.30 2.14 2.26 1.25 1.99 2.26 6600 2.42 18.2 1.51 2.87 3.11 1.62 2.71 3.11
6900 1.64 28.0 1.16 1.94 2.07 1.07 1.78 2.05 6900 2.12 21.7 1.36 2.59 2.85 1.40 2.40 2.85
7200 1.45 33.2 1.05 1.76 1.90 0.93 1.59 1.85 1.90 7200 1.87 25.7 1.23 2.34 2.61 1.22 2.14 2.57
7500 1.28 39.1 0.95 1.60 1.75 0.81 1.41 1.67 1.75 7500 1.65 30.3 1.12 2.13 2.41 1.06 1.88 2.31 2.41
7800 1.14 45.8 0.86 1.47 1.62 0.71 1.24 1.52 1.62 7800 1.47 35.4 1.02 1.94 2.23 0.93 1.65 2.09 2.23
8100 1.02 53.2 0.78 1.34 1.50 0.62 1.10 1.38 1.50 8100 1.31 41.2 0.93 1.78 2.07 0.83 1.45 1.89 2.07
8400 0.91 61.5 0.72 1.24 1.39 0.55 0.97 1.26 1.39 8400 1.18 47.6 0.85 1.63 1.92 0.73 1.28 1.72 1.92
8700 0.82 70.8 0.66 1.14 1.30 0.49 0.87 1.15 1.28 8700 1.06 54.8 0.78 1.50 1.79 0.65 1.14 1.56 1.78
9000 0.74 81.1 0.60 1.05 1.20 0.43 0.78 1.05 1.18 9000 0.96 62.8 0.72 1.38 1.66 0.59 1.01 1.43 1.64
9300 0.67 92.5 0.55 0.97 1.11 1.14 0.69 0.97 1.09 9300 0.87 71.6 0.66 1.28 1.53 1.57 0.53 0.91 1.31 1.50
9600 0.61 105.1 0.51 0.90 1.03 1.07 0.62 0.88 1.00 9600 0.79 81.2 0.61 1.18 1.42 1.47 0.48 0.81 1.20 1.38
9900 0.56 118.7 0.47 0.84 0.96 1.00 0.55 0.81 0.93 9900 0.72 91.9 0.57 1.09 1.31 1.38 0.43 0.73 1.08 1.28
10200 0.51 133.9 0.44 0.78 0.89 0.95 0.50 0.73 0.86 10200 0.66 103.5 0.53 1.00 1.22 1.30 0.66 0.98 1.18
10500 0.47 150.2 0.41 0.72 0.83 0.89 0.45 0.67 0.80 10500 0.60 116.3 0.49 0.92 1.13 1.23 0.60 0.89 1.09
10800 0.43 168.2 0.67 0.78 0.84 0.41 0.61 0.74 10800 0.55 130.2 0.46 0.85 1.06 1.16 0.54 0.80 1.01
11100 0.39 187.8 0.62 0.73 0.79 0.55 0.69 11100 0.51 145.4 0.43 0.79 0.99 1.10 0.49 0.73 0.94
11400 0.36 208.8 0.57 0.68 0.75 0.51 0.65 11400 0.47 161.7 0.40 0.73 0.92 1.04 0.45 0.67 0.87
11700 0.34 231.5 0.53 0.64 0.70 0.47 0.60 11700 0.44 179.3 0.68 0.86 0.97 0.41 0.61 0.81
12000 0.31 256.4 0.50 0.60 0.66 0.43 0.56 12000 0.40 198.5 0.63 0.81 0.91 0.56 0.76

12300 0.29 282.8 0.46 0.56 0.62 0.52 12300 0.37 219.3 0.59 0.76 0.86 0.51 0.70
12600 0.27 311.1 0.43 0.53 0.58 0.48 12600 0.35 241.4 0.55 0.71 0.81 0.47 0.64
12900 0.25 342.6 0.40 0.50 0.55 0.44 12900 0.33 264.6 0.51 0.67 0.76 0.43 0.59
13200 0.23 376.1 0.47 0.52 0.41 13200 0.30 290.4 0.48 0.63 0.72 0.40 0.55
13500 0.28 318.0 0.45 0.59 0.67 0.51
13800 0.27 347.2 0.42 0.55 0.64 0.47
14100 0.25 377.5 0.52 0.60 0.43
14400 0.23 412.0 0.48 0.57 0.40

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

www.fielders.com.au 59
FINISH ON TOP WITH FIELDERS
10.21

Double Lapped Spans lap


PURLIN & GIRT DESIGN MANUAL

200Z
Limit State Capacity Tables span (mm) span (mm)
overall purlin length =
span + 70mm + (lap/2)

200Z15 200Z19
Bridging (kN/m) Bridging (kN/m)
Span Span
k Inward Outward k Inward Outward
(mm) L /150 (mm) L /150
0 1 2 3 0 1 2 3 0 1 2 3 0 1 2 3

3000 33.27 0.6 7.43 7.43 3000 44.33 0.5 12.64 13.33 13.33
3300 25.00 0.9 6.53 6.53 3300 33.31 0.7 9.98 11.54 11.54
3600 19.25 1.2 5.77 5.77 3600 25.66 0.9 8.07 10.07 10.07
3900 15.14 1.7 5.14 5.14 3900 20.18 1.3 6.65 8.86 8.86
4200 12.13 2.3 4.45 4.61 4.61 4200 16.16 1.7 5.57 7.85 7.85
4500 9.86 3.0 3.77 4.15 4.15 4500 13.14 2.3 4.73 6.99 6.99
4800 8.12 3.9 3.23 3.75 3.75 4800 10.82 3.0 4.07 6.23 6.08 6.23
5100 6.77 5.0 2.79 3.41 3.41 5100 9.02 3.8 3.53 5.52 5.16 5.52
5400 5.71 6.3 2.44 3.11 3.11 5400 7.60 4.7 3.09 4.92 4.41 4.92
5700 4.85 7.8 2.15 2.84 2.68 2.84 5700 6.46 5.9 2.72 4.42 3.72 4.42
6000 4.16 9.6 1.90 2.61 2.28 2.61 6000 5.54 7.2 2.40 3.99 3.09 3.99
6300 3.59 11.7 1.69 2.41 1.95 2.41 6300 4.79 8.8 2.14 3.62 2.67 3.62
6600 3.13 14.1 1.52 2.21 1.67 2.21 6600 4.16 10.6 1.91 3.30 2.33 3.30
6900 2.73 16.8 1.36 2.02 1.45 2.02 6900 3.64 12.6 1.72 3.02 2.04 3.02
7200 2.41 19.9 1.23 1.86 1.26 1.86 7200 3.21 15.0 1.55 2.77 1.79 2.76
7500 2.13 23.5 1.12 1.71 1.10 1.71 7500 2.84 17.6 1.41 2.55 1.58 2.47 2.55
7800 1.89 27.5 1.02 1.58 0.97 1.55 1.58 7800 2.52 20.6 1.28 2.35 1.39 2.22 2.36
8100 1.69 32.0 0.93 1.47 0.83 1.41 1.47 8100 2.25 24.0 1.17 2.15 1.23 2.00 2.19
8400 1.52 36.9 0.85 1.37 0.74 1.27 1.37 8400 2.02 27.7 1.08 1.97 2.04 1.09 1.80 2.04
8700 1.36 42.5 0.78 1.27 0.67 1.14 1.27 8700 1.82 31.9 0.99 1.81 1.90 0.97 1.61 1.90
9000 1.23 48.7 0.72 1.19 0.60 1.02 1.19 9000 1.64 36.5 0.91 1.67 1.77 0.86 1.40 1.77
9300 1.12 55.5 0.66 1.11 0.54 0.92 1.11 9300 1.49 41.7 0.84 1.55 1.66 0.77 1.27 1.66
9600 1.02 63.1 0.60 1.04 0.49 0.83 1.05 9600 1.35 47.3 0.78 1.43 1.56 0.69 1.15 1.55
9900 0.93 71.3 0.56 0.97 0.44 0.75 0.98 9900 1.23 53.5 0.72 1.33 1.47 0.62 1.05 1.42 1.47
10200 0.85 80.4 0.52 0.91 0.93 0.40 0.68 0.91 10200 1.13 60.3 0.67 1.23 1.38 0.55 0.96 1.31 1.38
10500 0.78 90.2 0.48 0.85 0.87 0.61 0.85 0.87 10500 1.03 67.7 0.62 1.15 1.30 0.50 0.88 1.21 1.30
10800 0.71 101.0 0.45 0.79 0.83 0.56 0.79 0.83 10800 0.95 75.8 0.58 1.06 1.23 0.45 0.80 1.12 1.23
11100 0.66 112.6 0.42 0.74 0.78 0.51 0.73 0.78 11100 0.88 84.6 0.54 0.99 1.17 0.41 0.74 1.03 1.17
11400 0.61 125.4 0.69 0.74 0.46 0.67 0.74 11400 0.81 94.1 0.51 0.92 1.11 0.68 0.95 1.11
11700 0.56 139.0 0.65 0.70 0.43 0.62 0.70 11700 0.75 104.4 0.48 0.83 1.05 0.62 0.87 1.05
12000 0.52 153.8 0.61 0.67 0.57 0.67 12000 0.69 115.4 0.45 0.78 1.00 0.57 0.78 0.98

12300 0.48 169.8 0.57 0.64 0.52 0.64 12300 0.64 127.5 0.42 0.73 0.95 0.52 0.72 0.92
12600 0.45 187.1 0.53 0.61 0.48 0.60 12600 0.60 140.5 0.69 0.89 0.48 0.67 0.86
12900 0.42 205.7 0.50 0.58 0.44 0.56 12900 0.56 154.1 0.65 0.84 0.86 0.45 0.63 0.81
13200 0.39 225.1 0.47 0.55 0.41 0.53 13200 0.52 169.2 0.61 0.79 0.82 0.41 0.58 0.76
13500 0.37 246.6 0.44 0.53 0.50 13500 0.49 185.2 0.57 0.75 0.79 0.54 0.71
13800 0.34 269.0 0.41 0.50 0.47 13800 0.46 202.2 0.54 0.70 0.75 0.51 0.66
14100 0.32 293.8 0.47 0.48 0.44 14100 0.43 220.1 0.51 0.66 0.72 0.48 0.62
14400 0.30 318.9 0.45 0.46 0.41 14400 0.40 239.4 0.48 0.63 0.69 0.45 0.58
14700 0.38 259.9 0.46 0.59 0.66 0.42 0.53
15000 0.36 281.7 0.43 0.56 0.64 0.49
15300 0.33 305.4 0.41 0.53 0.61 0.47
15600 0.32 330.2 0.50 0.59 0.44
15900 0.30 355.7 0.47 0.56 0.41

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

60 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15
10.21

lap

PURLIN & GIRT DESIGN MANUAL


Double Lapped Spans
200Z
Limit State Capacity Tables span (mm) span (mm)
overall purlin length =
span + 70mm + (lap/2)

200Z24
Bridging (kN/m)
Span
k Inward Outward
(mm) L /150
0 1 2 3 0 1 2 3

4200 20.46 1.4 6.91 11.32 11.18


4500 16.64 1.8 5.81 9.94 9.43 9.94
4800 13.71 2.3 4.92 8.73 8.02 8.73
5100 11.43 3.0 4.22 7.74 6.86 7.74
5400 9.63 3.7 3.66 6.90 5.91 6.90
5700 8.19 4.6 3.20 6.15 5.07 6.19
6000 7.02 5.7 2.82 5.47 5.59 4.34 5.59
6300 6.06 6.9 2.50 4.90 5.07 3.70 5.07
6600 5.27 8.3 2.23 4.41 4.62 3.18 4.52 4.62
6900 4.62 10.0 2.00 3.98 4.23 2.76 4.05 4.23
7200 4.06 11.8 1.81 3.61 3.88 2.40 3.64 3.88
7500 3.59 13.9 1.64 3.29 3.58 2.11 3.28 3.58
7800 3.20 16.3 1.49 3.01 3.31 1.84 2.97 3.31
8100 2.85 18.9 1.36 2.76 3.07 1.62 2.69 3.07
8400 2.56 21.9 1.25 2.53 2.85 1.43 2.44 2.85
8700 2.30 25.2 1.15 2.34 2.66 1.26 2.21 2.62
9000 2.08 28.8 1.06 2.16 2.48 1.12 1.99 2.41 2.48
9300 1.89 32.9 0.97 2.00 2.33 1.00 1.80 2.22 2.33
9600 1.71 37.3 0.90 1.86 2.18 0.90 1.62 2.05 2.18
9900 1.56 42.2 0.84 1.72 2.05 0.81 1.46 1.89 2.05
10200 1.43 47.6 0.78 1.60 1.93 0.73 1.32 1.75 1.93
10500 1.31 53.4 0.73 1.48 1.81 0.66 1.20 1.62 1.82
10800 1.20 59.8 0.68 1.38 1.69 1.73 0.60 1.09 1.51 1.70
11100 1.11 66.7 0.63 1.29 1.58 1.63 0.55 1.00 1.40 1.59
11400 1.02 74.3 0.59 1.20 1.49 1.55 0.50 0.92 1.30 1.48
11700 0.95 82.4 0.56 1.12 1.40 1.47 0.46 0.84 1.20 1.39
12000 0.88 91.2 0.52 1.05 1.32 1.40 0.42 0.76 1.11 1.30

12300 0.82 100.6 0.49 0.98 1.24 1.33 0.70 1.03 1.22
12600 0.76 110.8 0.46 0.92 1.17 1.27 0.64 0.95 1.15
12900 0.71 121.8 0.44 0.86 1.10 1.21 0.59 0.88 1.08
13200 0.66 133.5 0.41 0.81 1.04 1.16 0.55 0.81 1.02
13500 0.62 146.1 0.76 0.99 1.10 0.50 0.75 0.96
13800 0.58 159.4 0.71 0.93 1.04 0.47 0.70 0.90
14100 0.54 173.8 0.67 0.88 0.99 0.43 0.65 0.85
14400 0.51 189.0 0.63 0.84 0.94 0.40 0.61 0.80
14700 0.48 205.5 0.60 0.80 0.89 0.57 0.75
15000 0.45 222.7 0.57 0.75 0.85 0.53 0.71
15300 0.42 241.1 0.54 0.71 0.81 0.49 0.66
15600 0.40 260.7 0.51 0.68 0.77 0.46 0.62
15900 0.38 281.2 0.48 0.64 0.74 0.43 0.58
16200 0.36 302.5 0.46 0.61 0.70 0.40 0.54
16500 0.34 325.4 0.43 0.58 0.67 0.51
16800 0.32 350.0 0.41 0.55 0.64 0.48
17100 0.30 376.2 0.52 0.61 0.45
17400 0.29 402.8 0.49 0.59 0.43
17700 0.27 432.2 0.46 0.56 0.40

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

www.fielders.com.au 61
FINISH ON TOP WITH FIELDERS
10.22

Double Lapped Spans lap


PURLIN & GIRT DESIGN MANUAL

250Z
Limit State Capacity Tables span (mm) span (mm)
overall purlin length =
span + 70mm + (lap/2)

250Z19 250Z24
Bridging (kN/m) Bridging (kN/m)
Span Span
k Inward Outward k Inward Outward
(mm) L /150 (mm) L /150
0 1 2 3 0 1 2 3 0 1 2 3 0 1 2 3

3600 42.20 0.6 9.82 9.82


3900 33.19 0.8 8.32 8.80 8.80
4200 26.57 1.1 6.95 7.92 7.92
4500 21.60 1.4 5.89 7.17 7.17
4800 17.80 1.8 5.05 6.51 6.51
5100 14.84 2.3 4.37 5.94 5.94
5400 12.50 2.9 3.82 5.44 5.44 5400 16.33 2.2 4.54 8.78 7.88 8.78
5700 10.63 3.6 3.37 5.00 4.81 5.00 5700 13.89 2.7 3.97 7.94 6.70 7.94
6000 9.11 4.4 2.98 4.60 3.97 4.60 6000 11.91 3.4 3.49 7.16 5.66 7.16
6300 7.87 5.3 2.64 4.25 3.41 4.25 6300 10.29 4.1 3.09 6.50 4.82 6.50
6600 6.85 6.4 2.36 3.94 2.96 3.94 6600 8.95 4.9 2.76 5.91 4.14 5.92
6900 5.99 7.7 2.12 3.66 2.58 3.66 6900 7.83 5.9 2.47 5.33 3.58 5.42
7200 5.27 9.1 1.91 3.39 2.26 3.39 7200 6.89 7.0 2.23 4.83 4.97 3.11 4.91
7500 4.67 10.7 1.73 3.12 1.99 3.12 7500 6.10 8.2 2.02 4.39 4.58 2.70 4.41 4.58
7800 4.15 12.5 1.58 2.88 1.75 2.88 7800 5.42 9.6 1.83 4.01 4.24 2.35 3.98 4.24
8100 3.70 14.6 1.44 2.67 1.54 2.61 2.67 8100 4.84 11.2 1.67 3.67 3.93 2.06 3.60 3.93
8400 3.32 16.9 1.32 2.49 1.36 2.32 2.49 8400 4.34 12.9 1.53 3.36 3.65 1.81 3.24 3.66
8700 2.99 19.4 1.21 2.32 1.20 2.07 2.32 8700 3.91 14.8 1.41 3.10 3.41 1.60 2.91 3.41
9000 2.70 22.2 1.12 2.16 1.07 1.80 2.17 9000 3.53 17.0 1.29 2.85 3.18 1.42 2.61 3.18
9300 2.45 25.3 1.03 2.01 0.96 1.62 2.03 9300 3.20 19.4 1.19 2.62 2.98 1.27 2.34 2.98
9600 2.23 28.8 0.95 1.86 1.90 0.86 1.47 1.90 9600 2.91 22.0 1.11 2.42 2.80 1.13 2.10 2.76
9900 2.03 32.5 0.88 1.71 1.79 0.77 1.33 1.79 9900 2.65 24.9 1.03 2.24 2.63 1.02 1.90 2.55 2.63
10200 1.86 36.7 0.82 1.58 1.69 0.69 1.21 1.69 10200 2.42 28.1 0.95 2.07 2.48 0.92 1.71 2.35 2.48
10500 1.70 41.2 0.77 1.46 1.59 0.62 1.11 1.58 10500 2.22 31.5 0.89 1.92 2.34 0.83 1.56 2.18 2.34
10800 1.56 46.1 0.71 1.35 1.50 0.56 1.01 1.46 1.50 10800 2.04 35.3 0.83 1.77 2.21 0.75 1.42 2.02 2.21
11100 1.44 51.4 0.67 1.22 1.42 0.51 0.93 1.33 1.42 11100 1.88 39.3 0.77 1.65 2.09 0.68 1.29 1.87 2.09
11400 1.33 57.2 0.63 1.13 1.35 0.47 0.85 1.22 1.35 11400 1.74 43.8 0.72 1.53 1.98 0.62 1.17 1.72 1.98
11700 1.23 63.5 0.59 1.06 1.28 0.42 0.78 1.08 1.28 11700 1.61 48.6 0.68 1.43 1.88 0.57 1.07 1.59 1.88
12000 1.14 70.2 0.55 0.99 1.22 0.71 1.00 1.22 12000 1.49 53.8 0.64 1.33 1.76 0.52 0.97 1.46 1.76

12300 1.06 77.5 0.52 0.93 1.16 0.65 0.92 1.16 12300 1.38 59.3 0.60 1.24 1.66 1.70 0.48 0.89 1.34 1.65
12600 0.98 85.4 0.48 0.87 1.11 0.60 0.86 1.11 12600 1.29 65.3 0.57 1.17 1.56 1.62 0.44 0.82 1.23 1.55
12900 0.92 93.8 0.46 0.82 1.05 0.55 0.79 1.05 12900 1.20 71.8 0.53 1.09 1.47 1.55 0.40 0.75 1.14 1.45
13200 0.86 102.8 0.43 0.77 1.01 0.51 0.74 0.99 13200 1.12 78.7 0.50 1.03 1.39 1.48 0.69 1.05 1.36
13500 0.80 112.5 0.40 0.72 0.96 0.47 0.69 0.92 13500 1.05 86.1 0.48 0.96 1.31 1.42 0.64 0.98 1.28
13800 0.75 122.8 0.68 0.91 0.44 0.64 0.86 13800 0.98 94.0 0.45 0.91 1.24 1.35 0.59 0.91 1.20
14100 0.70 133.9 0.64 0.87 0.41 0.60 0.80 14100 0.92 102.4 0.43 0.86 1.18 1.30 0.54 0.84 1.12
14400 0.66 145.7 0.61 0.81 0.85 0.56 0.72 14400 0.86 111.5 0.40 0.81 1.11 1.24 0.50 0.79 1.05
14700 0.62 158.1 0.57 0.76 0.81 0.52 0.67 14700 0.81 121.0 0.76 1.05 1.19 0.47 0.73 0.98
15000 0.58 171.5 0.54 0.72 0.78 0.49 0.63 15000 0.76 131.2 0.72 0.99 1.15 0.43 0.68 0.92
15300 0.55 185.5 0.51 0.68 0.75 0.46 0.59 15300 0.72 142.1 0.68 0.93 1.09 0.40 0.63 0.86
15600 0.52 200.4 0.49 0.62 0.72 0.43 0.56 15600 0.68 153.4 0.64 0.88 1.04 0.59 0.80
15900 0.49 216.3 0.46 0.58 0.69 0.52 15900 0.64 165.6 0.61 0.83 0.99 0.55 0.75
16200 0.46 233.3 0.44 0.55 0.67 0.49 16200 0.61 178.5 0.57 0.78 0.94 0.51 0.71
16500 0.44 251.1 0.42 0.52 0.64 0.47 16500 0.57 192.0 0.54 0.74 0.90 0.48 0.66
16800 0.42 269.9 0.50 0.62 0.44 16800 0.54 206.6 0.51 0.70 0.86 0.45 0.62
17100 0.39 289.3 0.47 0.60 0.42 17100 0.51 221.8 0.49 0.66 0.82 0.42 0.59
17400 0.49 237.7 0.46 0.63 0.78 0.56
17700 0.46 254.3 0.44 0.59 0.75 0.52
18000 0.44 272.1 0.42 0.56 0.71 0.49

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

62 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15

PURLIN & GIRT DESIGN MANUAL


This page intentionally blank

www.fielders.com.au 63
FINISH ON TOP WITH FIELDERS
10.23

Three Continuous Spans


PURLIN & GIRT DESIGN MANUAL

75LC span (mm) span (mm) span (mm)


Limit State Capacity Tables
overall purlin length = 3 x span + 70mm

75LC10 75LC12
Bridging (kN/m) Bridging (kN/m)
Span Span
k Inward Outward k Inward Outward
(mm) L /150 (mm) L /150
0 1,2,3 0 1 2 3 0 1,2,3 0 1 2 3

2100 3.09 4.5 3.43 3.43 2100 3.93 3.6 4.06 4.40 4.30 4.40
2400 2.07 7.7 2.62 2.47 2.62 2400 2.63 6.1 3.05 3.37 2.98 3.37
2700 1.46 12.4 2.04 1.79 2.07 2700 1.85 9.8 2.37 2.66 2.21 2.66
3000 1.06 18.9 1.61 1.68 1.29 1.68 3000 1.35 14.9 1.88 2.16 1.66 2.16
3300 0.80 27.6 1.30 1.39 0.95 1.38 3300 1.01 21.8 1.52 1.78 1.26 1.65 1.78
3600 0.61 39.1 1.06 1.17 0.70 1.09 1.17 3600 0.78 30.8 1.25 1.50 0.97 1.32 1.50
3900 0.48 53.8 0.87 0.99 0.55 0.88 0.99 3900 0.61 42.4 1.04 1.28 0.75 1.08 1.28

4200 0.39 72.4 0.73 0.86 0.44 0.71 0.86 4200 0.49 57.0 0.88 1.10 0.59 0.89 1.10
4500 0.31 95.5 0.60 0.75 0.56 0.75 4500 0.40 75.2 0.74 0.96 0.47 0.73 0.89 0.96
4800 0.26 123.6 0.50 0.66 0.46 0.63 0.66 4800 0.33 97.3 0.63 0.84 0.60 0.76 0.84
5100 0.22 157.4 0.43 0.58 0.54 0.58 5100 0.27 124.1 0.54 0.75 0.50 0.65 0.75
5400 0.18 197.8 0.52 0.46 0.52 5400 0.23 155.8 0.47 0.67 0.42 0.56 0.66
5700 0.16 245.2 0.47 0.46 5700 0.20 193.9 0.40 0.60 0.49 0.55
6000 0.13 300.8 0.42 0.40 6000 0.17 238.1 0.54 0.42 0.49

75LC15
Bridging (kN/m)
Span
k Inward Outward
(mm) L /150
0 1,2,3 0 1 2 3

2100 5.06 2.8 5.25 5.48 5.48


2400 3.39 4.7 3.95 4.20 4.02 4.20
2700 2.38 7.6 3.07 3.31 3.02 3.31
3000 1.74 11.5 2.45 2.69 2.29 2.69
3300 1.31 16.9 1.99 2.22 1.76 2.21
3600 1.01 23.9 1.64 1.86 1.34 1.80 1.86
3900 0.79 32.9 1.37 1.59 1.04 1.48 1.59

4200 0.63 44.2 1.16 1.37 0.82 1.23 1.37


4500 0.52 58.3 0.98 1.19 0.65 1.02 1.19
4800 0.42 75.5 0.84 1.05 0.53 0.85 1.03 1.05
5100 0.35 96.0 0.72 0.93 0.44 0.70 0.89 0.93
5400 0.30 120.8 0.62 0.83 0.59 0.77 0.83
5700 0.25 150.2 0.54 0.74 0.49 0.67 0.74
6000 0.22 184.3 0.47 0.67 0.41 0.59 0.66

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

64 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15

PURLIN & GIRT DESIGN MANUAL


This page intentionally blank

www.fielders.com.au 65
FINISH ON TOP WITH FIELDERS
10.24

Three Continuous Spans


PURLIN & GIRT DESIGN MANUAL

100LC/100Z span (mm) span (mm) span (mm)


Limit State Capacity Tables
overall purlin length = 3 x span + 70mm

100LC10/100Z10 100LC12/100Z12
Bridging (kN/m) Bridging (kN/m)
Span Span
k Inward Outward k Inward Outward
(mm) L /150 (mm) L /150
0 1,2,3 0 1 2 3 0 1,2,3 0 1 2 3

2100 6.28 2.2 4.44 4.44 2100 7.95 1.8 6.22 6.33
2400 4.21 3.8 3.60 3.60 2400 5.33 3.0 4.66 4.87 4.68 4.87
2700 2.96 6.1 2.97 2.80 2.97 2700 3.74 4.8 3.51 3.85 3.39 3.85
3000 2.16 9.3 2.41 2.03 2.41 3000 2.73 7.3 2.79 3.12 2.55 3.12
3300 1.62 13.6 1.95 1.99 1.49 1.99 3300 2.05 10.7 2.26 2.58 1.92 2.58
3600 1.25 19.2 1.59 1.67 1.11 1.67 3600 1.58 15.2 1.86 2.17 1.48 2.08 2.17
3900 0.98 26.5 1.31 1.43 0.85 1.38 1.43 3900 1.24 21.0 1.55 1.85 1.13 1.66 1.85

4200 0.79 35.7 1.09 1.23 0.68 1.11 1.23 4200 0.99 28.2 1.29 1.59 0.87 1.37 1.59
4500 0.64 47.0 0.90 1.07 0.54 0.89 1.07 4500 0.81 37.1 1.09 1.39 0.68 1.12 1.39
4800 0.53 60.8 0.75 0.94 0.43 0.72 0.94 4800 0.67 48.0 0.92 1.22 0.54 0.92 1.19 1.22
5100 0.44 77.4 0.64 0.83 0.58 0.83 5100 0.56 61.3 0.79 1.08 0.44 0.77 1.02 1.08
5400 0.37 97.6 0.54 0.74 0.48 0.72 0.74 5400 0.47 76.9 0.68 0.96 0.64 0.86 0.96
5700 0.31 121.0 0.46 0.67 0.61 0.67 5700 0.40 95.5 0.59 0.86 0.53 0.75 0.86
6000 0.27 148.7 0.40 0.60 0.52 0.60 6000 0.34 117.3 0.51 0.78 0.44 0.65 0.76

100LC24/100Z24
Bridging (kN/m)
Span
k Inward Outward
(mm) L /150
0 1,2,3 0 1 2 3

2100 16.14 0.9 11.58 13.89 13.89


2400 10.82 1.5 8.56 10.64 10.01 10.64
2700 7.60 2.4 6.57 8.41 7.35 8.41
3000 5.54 3.6 5.19 6.81 5.52 6.81
3300 4.16 5.3 4.18 5.63 4.23 5.63
3600 3.20 7.5 3.41 4.73 3.21 4.51 4.73
3900 2.52 10.3 2.83 4.03 2.49 3.65 4.03

4200 2.02 13.9 2.38 3.48 1.97 3.00 3.48


4500 1.64 18.3 2.02 3.03 1.58 2.48 3.03
4800 1.35 23.7 1.73 2.66 1.29 2.07 2.59 2.66
5100 1.13 30.2 1.50 2.36 1.07 1.72 2.21 2.36
5400 0.95 37.9 1.31 2.10 0.90 1.43 1.90 2.10
5700 0.81 47.1 1.15 1.88 0.77 1.20 1.65 1.89
6000 0.69 57.8 1.01 1.68 0.66 1.01 1.43 1.66

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

66 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15
10.24

PURLIN & GIRT DESIGN MANUAL


Three Continuous Spans
100LC/100Z span (mm) span (mm) span (mm)
Limit State Capacity Tables
overall purlin length = 3 x span + 70mm

100LC15/100Z15 100LC19/100Z19
Bridging (kN/m) Bridging (kN/m)
Span Span
k Inward Outward k Inward Outward
(mm) L /150 (mm) L /150
0 1,2,3 0 1 2 3 0 1,2,3 0 1 2 3

2100 10.18 1.4 7.76 8.13 8.13 2100 12.84 1.1 9.57 10.92 10.92
2400 6.82 2.3 5.80 6.22 6.07 6.22 2400 8.60 1.9 7.09 8.36 7.86 8.36
2700 4.79 3.8 4.48 4.92 4.50 4.92 2700 6.04 3.0 5.45 6.61 5.76 6.61
3000 3.49 5.7 3.54 3.98 3.38 3.98 3000 4.41 4.5 4.30 5.35 4.30 5.35
3300 2.62 8.4 2.86 3.29 2.56 3.29 3300 3.31 6.6 3.46 4.42 3.22 4.37
3600 2.02 11.9 2.35 2.77 1.90 2.71 2.77 3600 2.55 9.4 2.84 3.72 2.42 3.52 3.72
3900 1.59 16.4 1.96 2.36 1.45 2.22 2.36 3900 2.01 13.0 2.34 3.17 1.86 2.86 3.17

4200 1.27 22.0 1.65 2.03 1.13 1.82 2.03 4200 1.61 17.4 1.96 2.73 1.45 2.33 2.73
4500 1.03 29.0 1.39 1.77 0.89 1.50 1.77 4500 1.31 23.0 1.65 2.38 1.16 1.92 2.37
4800 0.85 37.6 1.17 1.56 0.71 1.24 1.55 4800 1.08 29.8 1.40 2.09 0.94 1.58 2.02 2.09
5100 0.71 47.8 0.99 1.38 0.58 1.01 1.33 1.38 5100 0.90 37.9 1.20 1.85 0.77 1.29 1.73 1.85
5400 0.60 60.1 0.85 1.23 0.48 0.83 1.15 1.23 5400 0.76 47.7 1.04 1.65 0.64 1.06 1.49 1.65
5700 0.51 74.7 0.73 1.10 0.69 1.00 1.10 5700 0.64 59.2 0.90 1.48 0.54 0.89 1.28 1.47
6000 0.44 91.7 0.63 1.00 0.57 0.87 0.99 6000 0.55 72.6 0.78 1.33 0.46 0.74 1.11 1.29

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

www.fielders.com.au 67
FINISH ON TOP WITH FIELDERS
10.25

Three Continuous Spans


PURLIN & GIRT DESIGN MANUAL

100FC - Refer details page 7 span (mm) span (mm) span (mm)
Limit State Capacity Tables
overall purlin length = 3 x span + 70mm

100FC10 100FC12
Bridging (kN/m) Bridging (kN/m)
Span Span
k Inward Outward k Inward Outward
(mm) L /150 (mm) L /150
0 1,2,3 0 1 2 3 0 1,2,3 0 1 2 3

2100 6.97 2.0 4.89 4.89 2100 8.43 1.7 6.19 6.19
2400 4.67 3.4 3.91 3.91 2400 5.65 2.8 4.70 4.74
2700 3.28 5.5 3.09 3.09 2700 3.97 4.5 3.63 3.75 3.67 3.75
3000 2.39 8.4 2.50 2.33 2.50 3000 2.89 6.9 2.88 3.03 2.76 3.03
3300 1.80 12.2 2.04 1.72 2.07 3300 2.17 10.1 2.33 2.51 2.08 2.51
3600 1.38 17.3 1.67 1.74 1.29 1.74 3600 1.67 14.3 1.91 2.11 1.51 2.11
3900 1.09 23.9 1.39 1.48 0.99 1.48 3900 1.32 19.8 1.59 1.80 1.18 1.80

4200 0.87 32.1 1.16 1.28 0.78 1.25 1.28 4200 1.05 26.6 1.33 1.55 0.94 1.48 1.55
4500 0.71 42.3 0.97 1.11 0.62 1.02 1.11 4500 0.86 35.0 1.12 1.35 0.76 1.22 1.35
4800 0.58 54.8 0.81 0.98 0.49 0.83 0.98 4800 0.71 45.3 0.95 1.19 0.63 1.01 1.19
5100 0.49 69.8 0.69 0.87 0.40 0.68 0.87 5100 0.59 57.8 0.81 1.05 0.52 0.83 1.05
5400 0.41 87.8 0.59 0.77 0.56 0.77 5400 0.50 72.6 0.67 0.94 0.43 0.66 0.94
5700 0.35 108.9 0.51 0.69 0.47 0.69 5700 0.42 90.3 0.58 0.84 0.56 0.81 0.84
6000 0.30 133.8 0.44 0.63 0.59 0.63 6000 0.36 110.8 0.51 0.76 0.48 0.71 0.76

100FC15 100FC19
Bridging (kN/m) Bridging (kN/m)
Span Span
k Inward Outward k Inward Outward
(mm) L /150 (mm) L /150
0 1,2,3 0 1 2 3 0 1,2,3 0 1 2 3

2100 10.60 1.3 7.41 7.91 7.91 2100 13.76 1.0 10.02 11.23 11.23
2400 7.10 2.3 5.55 6.13 6.01 2400 9.22 1.7 7.42 8.60 8.50
2700 4.99 3.6 4.30 4.84 4.51 4.84 2700 6.47 2.8 5.69 6.79 6.40 6.79
3000 3.64 5.5 3.42 3.92 3.46 3.92 3000 4.72 4.2 4.50 5.50 4.84 5.50
3300 2.73 8.0 2.78 3.24 2.71 3.24 3300 3.55 6.2 3.63 4.55 3.73 4.55
3600 2.11 11.4 2.30 2.72 2.11 2.69 3600 2.73 8.8 2.99 3.82 2.90 3.81
3900 1.66 15.7 1.92 2.32 1.67 2.21 2.32 3900 2.15 12.1 2.48 3.26 2.26 3.14 3.26

4200 1.33 21.1 1.63 2.00 1.31 1.84 2.00 4200 1.72 16.3 2.08 2.81 1.79 2.61 2.81
4500 1.08 27.8 1.38 1.74 1.04 1.54 1.74 4500 1.40 21.5 1.77 2.45 1.42 2.17 2.45
4800 0.89 36.0 1.19 1.53 0.84 1.30 1.53 4800 1.15 27.8 1.51 2.15 1.15 1.82 2.15
5100 0.74 45.9 1.03 1.36 0.69 1.11 1.32 1.36 5100 0.96 35.4 1.31 1.90 0.94 1.53 1.88
5400 0.62 57.7 0.89 1.21 0.57 0.93 1.15 1.21 5400 0.81 44.5 1.14 1.70 0.78 1.29 1.64 1.70
5700 0.53 71.7 0.78 1.09 0.48 0.79 1.01 1.09 5700 0.69 55.2 1.00 1.52 0.65 1.08 1.43 1.52
6000 0.46 87.9 0.68 0.98 0.40 0.67 0.88 0.98 6000 0.59 67.8 0.88 1.38 0.55 0.92 1.25 1.38

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

68 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15

PURLIN & GIRT DESIGN MANUAL


This page intentionally blank

www.fielders.com.au 69
FINISH ON TOP WITH FIELDERS
10.26

Three Continuous Spans


PURLIN & GIRT DESIGN MANUAL

150LC/150Z span (mm) span (mm) span (mm)


Limit State Capacity Tables
overall purlin length = 3 x span + 70mm

150LC12/150Z12 150LC15/150Z15
Bridging (kN/m) Bridging (kN/m)
Span Span
k Inward Outward k Inward Outward
(mm) L /150 (mm) L /150
0 1,2,3 0 1 2,3 0 1,2,3 0 1 2,3

3000 8.59 2.3 4.46 4.46 3000 10.95 1.8 6.53 6.84 6.84
3300 6.46 3.4 3.88 3.88 3300 8.23 2.7 5.26 5.82 5.82
3600 4.97 4.8 3.40 3.40 3600 6.34 3.8 4.29 5.01 4.89 5.01
3900 3.91 6.6 3.00 3.00 3900 4.99 5.2 3.55 4.28 3.94 4.28

4200 3.13 8.9 2.60 2.67 2.59 2.67 4200 3.99 7.0 2.97 3.69 3.19 3.69
4500 2.55 11.8 2.20 2.39 2.07 2.39 4500 3.25 9.2 2.52 3.21 2.52 3.21
4800 2.10 15.3 1.89 2.14 1.68 2.14 4800 2.67 12.0 2.16 2.82 2.06 2.82
5100 1.75 19.4 1.63 1.94 1.37 1.94 5100 2.23 15.3 1.83 2.50 1.72 2.50
5400 1.47 24.4 1.42 1.75 1.14 1.75 5400 1.88 19.2 1.60 2.23 1.45 2.19
5700 1.25 30.3 1.24 1.57 0.95 1.54 1.57 5700 1.60 23.8 1.41 2.00 1.23 1.89 2.00
6000 1.07 37.2 1.09 1.42 0.80 1.34 1.42 6000 1.37 29.2 1.25 1.81 1.02 1.64 1.81
6300 0.93 45.3 0.96 1.29 0.68 1.15 1.29 6300 1.18 35.5 1.15 1.64 0.86 1.42 1.64

150LC19/150Z19 150LC24/150Z24
Bridging (kN/m) Bridging (kN/m)
Span Span
k Inward Outward k Inward Outward
(mm) L /150 (mm) L /150
0 1,2,3 0 1 2,3 0 1,2,3 0 1 2,3

3000 13.83 1.4 8.10 9.71 9.71 3000 17.72 1.1 9.89 13.51 13.51
3300 10.39 2.1 6.47 8.15 7.83 8.15 3300 13.32 1.7 7.82 11.16 10.72 11.16
3600 8.00 3.0 5.28 6.90 6.30 6.90 3600 10.26 2.3 6.33 9.38 8.54 9.38
3900 6.29 4.1 4.38 5.88 5.13 5.88 3900 8.07 3.2 5.20 7.99 6.86 7.99

4200 5.04 5.6 3.66 5.07 4.22 5.07 4200 6.46 4.3 4.33 6.89 5.57 6.89
4500 4.10 7.3 3.10 4.42 3.45 4.42 4500 5.25 5.7 3.66 6.00 4.47 6.00
4800 3.38 9.5 2.66 3.88 2.82 3.78 3.88 4800 4.33 7.4 3.13 5.28 3.65 5.19
5100 2.82 12.1 2.30 3.44 2.31 3.26 3.44 5100 3.61 9.4 2.70 4.67 2.98 4.47 4.67
5400 2.37 15.2 2.00 3.07 1.90 2.82 3.07 5400 3.04 11.8 2.35 4.17 2.46 3.85 4.17
5700 2.02 18.8 1.76 2.75 1.58 2.46 2.75 5700 2.58 14.7 2.07 3.74 2.04 3.32 3.74
6000 1.73 23.1 1.56 2.49 1.32 2.15 2.49 6000 2.22 18.1 1.83 3.38 1.72 2.88 3.38
6300 1.49 28.1 1.38 2.25 1.11 1.89 2.25 6300 1.91 21.9 1.62 3.04 1.45 2.51 3.06

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

70 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15
10.27

Three Continuous Spans

PURLIN & GIRT DESIGN MANUAL


200LC/200Z span (mm) span (mm) span (mm)
Limit State Capacity Tables
overall purlin length = 3 x span + 70mm

200LC15/200Z15 200LC19/200Z19
Bridging (kN/m) Bridging (kN/m)
Span Span
k Inward Outward k Inward Outward
(mm) L /150 (mm) L /150
0 1,2,3 0 1,2,3 0 1,2,3 0 1,2,3

3000 23.04 0.9 6.93 6.93


3300 17.31 1.3 6.08 6.08
3600 13.33 1.8 5.38 5.38 3600 17.77 1.4 7.76 9.36 9.36
3900 10.49 2.5 4.79 4.79 3900 13.97 1.9 6.39 8.23 8.23

4200 8.40 3.3 4.29 4.29 4200 11.19 2.5 5.35 7.29 7.29
4500 6.83 4.4 3.65 3.86 3.86 4500 9.10 3.3 4.54 6.49 6.20 6.49
4800 5.62 5.7 3.12 3.49 3.49 4800 7.50 4.3 3.90 5.76 5.18 5.76
5100 4.69 7.3 2.70 3.17 3.07 3.17 5100 6.25 5.4 3.39 5.10 4.21 5.10
5400 3.95 9.1 2.35 2.89 2.55 2.89 5400 5.26 6.8 2.96 4.55 3.49 4.55
5700 3.36 11.3 2.07 2.64 2.13 2.64 5700 4.48 8.5 2.61 4.08 2.96 4.08
6000 2.88 13.9 1.83 2.42 1.80 2.42 6000 3.84 10.4 2.32 3.69 2.54 3.69
6300 2.49 16.89 1.63 2.23 1.53 2.23 6300 3.32 12.7 2.07 3.34 2.19 3.34

200LC24/200Z24*
Bridging (kN/m)
Span
k Inward Outward
(mm) L /150
0 1,2,3 0 1 2,3

4200 14.13 2.0 6.68 10.48 9.82 10.48


4500 11.49 2.6 5.62 9.17 8.22 9.17
4800 9.47 3.4 4.78 8.06 6.94 8.06
5100 7.89 4.3 4.10 7.14 5.83 7.14
5400 6.65 5.4 3.55 6.37 4.86 6.37
5700 5.65 6.7 3.11 5.72 4.06 5.67
6000 4.85 8.3 2.73 5.16 3.43 4.99 5.16
6300 4.19 10.0 2.42 4.68 2.92 4.41 4.69

* All spans exceed standards delivery length of 12m

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

www.fielders.com.au 71
FINISH ON TOP WITH FIELDERS
10.28

Three Continuous Spans


PURLIN & GIRT DESIGN MANUAL

250LC/250Z span (mm) span (mm) span (mm)


Limit State Capacity Tables
overall purlin length = 3 x span + 70mm

250LC19/250Z19 250LC24/250Z24*
Bridging (kN/m) Bridging (kN/m)
Span Span
k Inward Outward k Inward Outward
(mm) L /150 (mm) L /150
0 1,2,3 0 1,2,3 0 1,2,3 0 1,2 3

3600 28.95 0.8 9.16 9.16


3900 22.77 1.1 8.03 8.20 8.20

4200 18.23 1.5 6.71 7.38 7.38


4500 14.82 2.0 5.68 6.67 6.67
4800 12.21 2.6 4.87 6.06 6.06
5100 10.18 3.3 4.21 5.53 5.41 5.53
5400 8.58 4.2 3.68 5.06 4.48 5.06 5400 11.01 3.3 4.24 8.05 5.81 8.05
5700 7.29 5.2 3.24 4.64 3.78 4.64 5700 9.36 4.1 3.70 7.23 4.79 7.23
6000 6.25 6.4 2.87 4.28 3.20 4.28 6000 8.03 5.0 3.26 6.52 3.99 6.52
6300 5.40 7.8 2.56 3.95 2.70 3.95 6300 6.93 6.1 2.89 5.91 3.35 5.78 5.91

* All spans exceed standards delivery length of 12m

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

72 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15
10.29

Three Continuous Spans

PURLIN & GIRT DESIGN MANUAL


300LC span (mm) span (mm) span (mm)
Limit State Capacity Tables
overall purlin length = 3 x span + 70mm

300LC24 300LC30
Bridging (kN/m) Bridging (kN/m)
Span Span
k Inward Outward k Inward Outward
(mm) L /150 (mm) L /150
0 1,2,3 0,1,2,3 0 1,2,3 0 1,2,3

3300 85.47 0.3 18.27 18.27 3300 109.85 0.2 31.63 31.63
3600 65.83 0.4 16.35 16.35 3600 84.61 0.3 26.46 27.88 27.88
3900 51.78 0.5 14.71 14.71 3900 66.55 0.4 20.71 24.75 24.7 5

4200 41.46 0.7 13.01 13.31 13.31 4200 53.28 0.5 16.56 22.10 22.10
4500 33.71 0.9 10.90 12.10 12.10 4500 43.32 0.7 13.49 19.84 19.84
4800 27.77 1.2 9.18 11.04 11.04 4800 35.69 0.9 11.16 17.90 17.90
5100 23.16 1.5 7.81 10.11 10.12 5100 29.76 1.1 9.37 16.21 16.22
5400 19.51 1.8 6.72 9.30 9.30 5400 25.07 1.4 7.97 14.76 14.76
5700 16.59 2.3 5.82 8.57 8.57 5700 21.32 1.8 6.84 13.47 13.46
6000 14.22 2.8 5.07 7.93 7.93 6000 18.27 2.2 5.94 12.35 11.78 12.35
6300 12.29 3.4 4.45 7.34 7.34 6300 15.79 2.7 5.19 11.35 10.32 11.35

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

www.fielders.com.au 73
FINISH ON TOP WITH FIELDERS
10.30

Three Continuous Spans


PURLIN & GIRT DESIGN MANUAL

350LC span (mm) span (mm) span (mm)


Limit State Capacity Tables
overall purlin length = 3 x span + 70mm

350LC30
Bridging (kN/m)
Span
k Inward Outward
(mm) L /150
0 1,2,3 0,1,2,3

2400 466.57 0.0 44.90 44.90


2700 327.69 0.1 39.16 39.16
3000 238.88 0.1 34.54 34.54
3300 179.48 0.1 30.73 30.73
3600 138.24 0.2 27.55 27.55
3900 108.73 0.2 24.84 24.84

4200 87.05 0.3 22.52 22.52


4500 70.78 0.42 20.35 20.50
4800 58.32 0.55 16.52 18.75 18.75
5100 48.62 0.70 14.00 17.19 17.20
5400 40.96 0.88 11.99 15.84 15.84
5700 34.83 1.09 10.37 14.62 14.62
6000 29.86 1.34 9.02 13.54 13.54
6300 25.79 1.63 7.84 12.57 12.57

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

74 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15
10.31

Three Continuous Spans

PURLIN & GIRT DESIGN MANUAL


400LC span (mm) span (mm) span (mm)
Limit State Capacity Tables
overall purlin length = 3 x span + 70mm

400LC30
Bridging (kN/m)
Span
k Inward Outward
(mm) L /150
0 1,2,3 0,1,2,3

2400 574.76 0.0 40.36 40.35


2700 403.66 0.0 35.46 35.46
3000 294.28 0.1 31.52 31.52
3300 221.08 0.1 28.27 28.26
3600 170.30 0.1 25.54 25.54
3900 133.95 0.2 23.22 23.22

4200 107.24 0.3 21.22 21.22


4500 87.19 0.34 19.09 19.48 19.48
4800 71.85 0.45 15.72 17.95 17.95
5100 59.90 0.57 13.13 16.59 16.60
5400 50.46 0.71 11.11 15.40 15.40
5700 42.90 0.89 9.51 14.31 14.32
6000 36.78 1.09 8.22 13.35 13.35
6300 31.78 1.32 7.16 12.47 12.48

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

www.fielders.com.au 75
FINISH ON TOP WITH FIELDERS
10.32

Three Lapped Spans end span


overall purlin length =
span + 70mm + lap end span
PURLIN & GIRT DESIGN MANUAL

100Z
Limit State Capacity Tables span (mm) span (mm) span (mm)
lap overall purlin length =
span + 70mm + (lap/2)

100Z10 100Z12
Bridging (kN/m) Bridging (kN/m)
Span Span
L /150 k Inward Outward k Inward Outward
(mm) (mm) L /150
0 1 2,3 0 1 2 3 0 1 2 3 0 1 2 3

2100 6.73 2.1 5.78 5.78 2100 8.53 1.6 7.34 8.28 8.26
2400 4.51 3.6 4.78 4.72 2400 5.72 2.8 5.49 6.34 5.68 6.34
2700 3.17 5.7 3.67 3.87 3.31 3.87 2700 4.01 4.5 4.24 5.01 4.15 5.01
3000 2.31 8.7 2.89 3.14 2.35 3.14 3000 2.93 6.8 3.35 4.05 3.02 4.05
3300 1.73 12.7 2.31 2.59 1.71 2.59 3300 2.20 10.0 2.69 3.35 2.27 3.30
3600 1.34 18.0 1.86 2.18 1.28 2.12 2.18 3600 1.69 14.2 2.19 2.82 1.70 2.55 2.82
3900 1.05 24.8 1.52 1.86 1.00 1.69 1.86 3900 1.33 19.5 1.81 2.40 1.29 2.07 2.40
4200 0.84 33.3 1.25 1.60 0.79 1.32 1.60 4200 1.07 26.3 1.52 2.07 0.99 1.67 2.07
4500 0.68 43.9 1.04 1.39 0.62 1.05 1.39 4500 0.87 34.6 1.28 1.80 0.78 1.36 1.76 1.81
4800 0.56 56.8 0.87 1.22 0.49 0.85 1.20 1.23 4800 0.71 44.8 1.09 1.58 0.62 1.11 1.44 1.59
5100 0.47 72.3 0.74 1.09 0.69 1.01 1.09 5100 0.60 57.0 0.93 1.40 0.50 0.92 1.23 1.41
5400 0.40 90.9 0.63 0.97 0.57 0.84 0.97 5400 0.50 71.7 0.80 1.25 0.40 0.76 1.05 1.24
5700 0.34 113.1 0.53 0.87 0.48 0.70 0.87 5700 0.43 89.0 0.69 1.12 0.63 0.90 1.08
6000 0.29 138.9 0.46 0.78 0.41 0.59 0.76 6000 0.37 109.3 0.59 1.01 0.52 0.77 0.91
6300 0.25 168.7 0.40 0.71 0.50 0.66 6300 0.32 132.9 0.52 0.90 0.92 0.44 0.66 0.80
6600 0.22 202.8 0.65 0.43 0.57 6600 0.28 160.0 0.45 0.80 0.84 0.57 0.71
6900 0.19 242.1 0.59 0.49 6900 0.24 190.9 0.70 0.77 0.49 0.62
7200 0.17 287.4 0.52 0.54 0.43 7200 0.21 226.4 0.63 0.70 0.43 0.55
7500 0.19 267.4 0.57 0.65 0.48
7800 0.17 313.3 0.51 0.59 0.60 0.43

100Z24
Bridging (kN/m)
Span
k Inward Outward
(mm) L /150
0 1 2 3 0 1 2 3

2100 17.31 0.8 13.49 18.22 17.59 18.22


2400 11.59 1.4 9.75 13.95 12.40 13.95
2700 8.14 2.2 7.37 11.02 8.99 11.02
3000 5.94 3.4 5.75 8.93 6.65 8.93
3300 4.46 4.9 4.61 7.38 4.87 7.10 7.38
3600 3.44 7.0 3.77 6.20 3.66 5.65 6.20
3900 2.70 9.6 3.13 5.27 2.82 4.55 5.28
4200 2.16 12.9 2.64 4.47 2.22 3.71 4.52
4500 1.76 17.1 2.25 3.83 3.97 1.78 3.04 3.79 3.97
4800 1.45 22.1 1.94 3.32 3.49 1.45 2.48 3.20 3.49
5100 1.21 28.1 1.68 2.90 3.09 1.20 2.03 2.72 3.09
5400 1.02 35.4 1.47 2.55 2.76 1.00 1.68 2.32 2.68
5700 0.87 43.9 1.29 2.26 2.47 0.85 1.40 1.99 2.32
6000 0.74 53.9 1.15 2.01 2.23 0.73 1.18 1.72 2.03
6300 0.64 65.5 1.02 1.80 2.02 0.63 1.00 1.48 1.78
6600 0.56 78.9 0.91 1.62 1.84 0.55 0.86 1.27 1.57
6900 0.49 94.3 0.82 1.46 1.69 0.48 0.74 1.09 1.38
7200 0.43 111.9 0.73 1.33 1.54 0.42 0.65 0.95 1.22
7500 0.38 131.6 0.66 1.21 1.40 1.43 0.57 0.83 1.09
7800 0.34 153.8 0.60 1.10 1.27 1.32 0.50 0.72 0.96
8100 0.30 178.8 0.54 1.01 1.16 1.23 0.44 0.64 0.84
8400 0.27 207.4 0.50 0.92 1.06 1.14 0.56 0.75
8700 0.24 238.7 0.45 0.85 0.97 1.05 0.50 0.66
9000 0.22 272.7 0.41 0.78 0.89 0.97 0.45 0.59
9300 0.20 311.6 0.72 0.82 0.89 0.40 0.53
9600 0.18 353.6 0.66 0.75 0.82 0.48
9900 0.17 400.0 0.61 0.69 0.76 0.43

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

76 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15
10.32
overall purlin length =
end span span + 70mm + lap end span

PURLIN & GIRT DESIGN MANUAL


Three Lapped Spans
100Z
Limit State Capacity Tables span (mm) span (mm) span (mm)
lap overall purlin length =
span + 70mm + (lap/2)

100Z15 100Z19
Bridging (kN/m) Bridging (kN/m)
Span Span
k Inward Outward k Inward Outward
(mm) L /150 (mm) L /150
0 1 2 3 0 1 2 3 0 1 2 3 0 1 2 3

2100 10.88 1.29 9.31 10.61 10.53 2100 13.75 1.0 11.24 14.25 13.72 14.25
2400 7.29 2.19 6.91 8.12 7.59 8.12 2400 9.21 1.7 8.23 10.91 9.77 10.91
2700 5.12 3.52 5.31 6.42 5.53 6.42 2700 6.47 2.8 6.21 8.62 7.04 8.62
3000 3.73 5.36 4.18 5.20 4.06 5.20 3000 4.72 4.2 4.84 6.98 5.10 6.98
3300 2.81 7.84 3.34 4.30 2.95 4.23 3300 3.54 6.2 3.86 5.77 3.71 5.52 5.77
3600 2.16 11.11 2.72 3.61 2.18 3.41 3.61 3600 2.73 8.8 3.15 4.85 2.76 4.42 4.85
3900 1.70 15.30 2.24 3.08 1.65 2.77 3.08 3900 2.15 12.1 2.60 4.13 2.11 3.56 4.13
4200 1.36 20.59 1.86 2.65 1.28 2.26 2.65 4200 1.72 16.3 2.18 3.56 1.64 2.88 3.50
4500 1.11 27.12 1.56 2.31 1.01 1.84 2.26 2.31 4500 1.40 21.5 1.84 3.07 1.31 2.34 2.95 3.11
4800 0.91 35.13 1.33 2.03 0.80 1.49 1.93 2.03 4800 1.15 27.8 1.57 2.66 2.73 1.05 1.88 2.50 2.73
5100 0.76 44.74 1.13 1.80 0.65 1.20 1.65 1.80 5100 0.96 35.4 1.35 2.33 2.42 0.86 1.52 2.12 2.40
5400 0.64 56.25 0.97 1.60 0.54 0.98 1.41 1.59 5400 0.81 44.5 1.17 2.05 2.16 0.71 1.25 1.81 2.08
5700 0.54 69.85 0.84 1.42 0.45 0.81 1.21 1.39 5700 0.69 55.2 1.02 1.82 1.93 0.60 1.04 1.55 1.81
6000 0.47 85.65 0.73 1.27 1.30 0.37 0.68 1.04 1.23 6000 0.59 67.8 0.89 1.62 1.75 0.51 0.87 1.32 1.59
6300 0.40 104.22 0.63 1.14 1.18 0.32 0.57 0.89 1.08 6300 0.51 82.5 0.79 1.45 1.58 0.44 0.73 1.12 1.39
6600 0.35 125.36 0.55 1.02 1.07 0.27 0.48 0.75 0.95 6600 0.44 99.3 0.70 1.31 1.44 0.63 0.95 1.22
6900 0.31 149.84 0.49 0.92 0.98 0.23 0.41 0.64 0.84 6900 0.39 118.6 0.62 1.18 1.32 0.54 0.82 1.07
7200 0.27 177.78 0.43 0.83 0.90 0.20 0.55 0.74 7200 0.34 140.8 0.55 1.06 1.19 0.46 0.71 0.95
7500 0.24 209.21 0.75 0.83 0.18 0.48 0.65 7500 0.30 165.6 0.49 0.96 1.08 1.12 0.40 0.61 0.83
7800 0.21 245.28 0.68 0.75 0.77 0.16 0.42 0.58 7800 0.27 194.0 0.44 0.87 0.98 1.03 0.53 0.73
8100 0.19 284.21 0.62 0.69 0.71 0.14 0.50 8100 0.24 225.0 0.79 0.90 0.96 0.47 0.64
8400 0.17 329.41 0.56 0.63 0.66 0.12 0.44 8400 0.22 260.5 0.72 0.82 0.88 0.41 0.56
8700 0.19 300.5 0.66 0.75 0.81 0.50
9000 0.18 342.9 0.60 0.69 0.75 0.44

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

www.fielders.com.au 77
FINISH ON TOP WITH FIELDERS
10.33

Three Lapped Spans end span


overall purlin length =
span + 70mm + lap end span
PURLIN & GIRT DESIGN MANUAL

150Z
Limit State Capacity Tables span (mm) span (mm) span (mm)
lap overall purlin length =
span + 70mm + (lap/2)

150Z12 150Z15
Bridging (kN/m) Bridging (kN/m)
Span Span
k Inward Outward k Inward Outward
(mm) L /150 (mm) L /150
0 1 2,3 0 1 2 3 0 1 2 3 0 1 2 3

3000 9.14 2.2 5.67 5.67 3000 11.65 1.7 7.34 9.28 9.28
3300 6.87 3.2 5.01 5.01 3300 8.76 2.5 5.88 7.90 7.56 7.90
3600 5.29 4.5 4.24 4.45 4.45 3600 6.74 3.6 4.81 6.64 5.97 6.64
3900 4.16 6.2 3.50 3.98 3.82 3.98 3900 5.30 4.9 4.01 5.65 4.71 5.65
4200 3.33 8.4 2.94 3.58 3.00 3.58 4200 4.25 6.6 3.38 4.88 3.68 4.88
4500 2.71 11.1 2.50 3.24 2.39 3.24 4500 3.45 8.7 2.89 4.25 3.00 4.25
4800 2.23 14.3 2.14 2.94 1.93 2.94 4800 2.85 11.2 2.49 3.73 2.47 3.71
5100 1.86 18.3 1.85 2.60 1.58 2.59 5100 2.37 14.3 2.17 3.31 2.03 3.16 3.31
5400 1.57 23.0 1.61 2.32 1.30 2.23 2.32 5400 2.00 18.0 1.90 2.95 1.67 2.71 2.95
5700 1.33 28.5 1.41 2.08 1.10 1.89 2.08 5700 1.70 22.4 1.67 2.65 1.37 2.33 2.65
6000 1.14 35.0 1.25 1.88 0.92 1.60 1.88 6000 1.46 27.5 1.48 2.39 1.14 1.99 2.39
6300 0.99 42.6 1.10 1.71 0.77 1.37 1.71 6300 1.26 33.4 1.31 2.17 0.96 1.67 2.17
6600 0.86 51.2 0.98 1.55 0.65 1.17 1.55 6600 1.09 40.2 1.17 1.97 0.81 1.45 1.94 1.98
6900 0.75 61.3 0.88 1.42 0.55 1.01 1.41 6900 0.96 48.0 1.04 1.81 0.69 1.27 1.72 1.81
7200 0.66 72.6 0.78 1.31 0.47 0.87 1.26 1.31 7200 0.84 56.9 0.93 1.66 0.59 1.12 1.53 1.66
7500 0.59 85.5 0.70 1.20 0.41 0.76 1.12 1.21 7500 0.75 67.0 0.84 1.51 0.51 0.98 1.37 1.53
7800 0.52 100.0 0.63 1.11 0.67 0.99 1.11 7800 0.66 78.4 0.75 1.38 1.41 0.44 0.86 1.22 1.42
8100 0.46 116.4 0.57 1.03 0.58 0.87 1.03 8100 0.59 91.2 0.68 1.27 1.31 0.75 1.08 1.29
8400 0.42 134.6 0.52 0.96 0.52 0.77 0.96 8400 0.53 105.5 0.62 1.17 1.22 0.66 0.95 1.17
8700 0.38 154.7 0.47 0.89 0.46 0.69 0.88 8700 0.48 121.3 0.56 1.08 1.14 0.58 0.85 1.07
9000 0.34 177.0 0.43 0.84 0.41 0.61 0.80 9000 0.43 138.9 0.51 0.99 1.06 0.51 0.77 0.97
9300 0.31 202.0 0.78 0.55 0.72 9300 0.39 158.6 0.46 0.92 1.00 0.45 0.69 0.89
9600 0.28 229.4 0.72 0.73 0.49 0.65 9600 0.36 179.8 0.42 0.85 0.93 0.40 0.63 0.81
9900 0.25 259.8 0.67 0.69 0.44 0.59 9900 0.32 203.7 0.79 0.88 0.57 0.73
10200 0.23 291.8 0.62 0.65 0.40 0.54 10200 0.30 229.7 0.73 0.83 0.52 0.66
10500 0.21 328.6 0.57 0.61 0.49 10500 0.27 257.4 0.68 0.78 0.47 0.60
10800 0.20 367.3 0.53 0.58 0.44 10800 0.25 288.0 0.63 0.74 0.43 0.55
11100 0.18 411.1 0.49 0.55 0.40 11100 0.23 321.7 0.59 0.69 0.50
11400 0.21 358.5 0.54 0.64 0.66 0.47
11700 0.20 398.0 0.51 0.60 0.63 0.43

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

78 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15
10.33
overall purlin length =
end span span + 70mm + lap end span

PURLIN & GIRT DESIGN MANUAL


Three Lapped Spans
150Z
Limit State Capacity Tables span (mm) span (mm) span (mm)
lap overall purlin length =
span + 70mm + (lap/2)

150Z19 150Z24
Bridging (kN/m) Bridging (kN/m)
Span Span
k Inward Outward k Inward Outward
(mm) L /150 (mm) L /150
0 1 2 3 0 1 2 3 0 1 2 3 0 1 2 3

3000 14.71 1.36 9.18 13.13 12.56 13.13 3000 19.01 1.1 10.82 18.09 17.24 18.09
3300 11.05 1.99 7.27 10.85 9.90 10.85 3300 14.28 1.5 8.46 14.95 13.43 14.95
3600 8.51 2.82 5.87 9.12 7.91 9.12 3600 11.00 2.2 6.79 12.57 10.63 12.57
3900 6.70 3.88 4.82 7.77 6.35 7.77 3900 8.65 3.0 5.56 10.71 8.41 10.71
4200 5.36 5.22 4.01 6.70 5.01 6.70 4200 6.93 4.0 4.63 9.23 6.53 9.23
4500 4.36 6.88 3.39 5.84 4.00 5.67 5.84 4500 5.63 5.3 3.91 8.02 5.15 7.84 8.04
4800 3.59 8.91 2.90 5.11 3.22 4.83 5.13 4800 4.64 6.9 3.35 6.92 7.07 4.12 6.64 7.07
5100 3.00 11.35 2.50 4.47 2.60 4.15 4.54 5100 3.87 8.8 2.89 6.02 6.26 3.34 5.66 6.26
5400 2.52 14.27 2.18 3.94 4.05 2.13 3.58 4.05 5400 3.26 11.0 2.53 5.29 5.59 2.74 4.85 5.59
5700 2.15 17.72 1.91 3.50 3.64 1.76 3.11 3.63 5700 2.77 13.7 2.22 4.67 5.01 2.27 4.18 5.01
6000 1.84 21.75 1.69 3.13 3.28 1.46 2.69 3.20 3.29 6000 2.38 16.8 1.97 4.16 4.52 1.90 3.61 4.44 4.53
6300 1.59 26.43 1.50 2.81 2.98 1.23 2.31 2.84 2.98 6300 2.05 20.5 1.75 3.72 4.10 1.61 3.05 3.92 4.11
6600 1.38 31.84 1.34 2.54 2.71 1.04 1.98 2.53 2.72 6600 1.79 24.6 1.57 3.34 3.74 1.37 2.60 3.47 3.74
6900 1.21 38.05 1.20 2.30 2.48 0.89 1.71 2.26 2.49 6900 1.56 29.4 1.41 3.02 3.42 1.18 2.22 3.08 3.43
7200 1.06 45.11 1.08 2.09 2.28 0.77 1.48 2.02 2.26 7200 1.38 34.9 1.27 2.74 3.14 1.02 1.91 2.75 3.14
7500 0.94 53.08 0.97 1.91 2.10 0.67 1.28 1.82 2.04 7500 1.22 41.1 1.16 2.50 2.90 0.89 1.66 2.46 2.83
7800 0.84 62.13 0.88 1.75 1.94 0.58 1.11 1.64 1.85 7800 1.08 48.1 1.05 2.28 2.68 0.78 1.44 2.21 2.55
8100 0.75 72.29 0.80 1.61 1.80 0.51 0.97 1.47 1.69 8100 0.97 55.9 0.96 2.10 2.48 0.69 1.26 1.97 2.31
8400 0.67 83.58 0.73 1.48 1.68 0.45 0.85 1.31 1.54 8400 0.87 64.7 0.88 1.93 2.31 0.61 1.11 1.74 2.10
8700 0.60 96.19 0.67 1.37 1.56 0.75 1.16 1.41 8700 0.78 74.4 0.81 1.78 2.14 0.54 0.98 1.54 1.91
9000 0.55 110.09 0.61 1.27 1.46 0.66 1.04 1.29 9000 0.70 85.2 0.74 1.64 1.98 0.48 0.87 1.36 1.74
9300 0.49 125.51 0.56 1.18 1.35 0.59 0.93 1.18 9300 0.64 97.2 0.69 1.52 1.84 1.89 0.43 0.78 1.22 1.59
9600 0.45 142.54 0.51 1.09 1.26 1.28 0.52 0.84 1.08 9600 0.58 110.3 0.63 1.41 1.71 1.77 0.69 1.09 1.46
9900 0.41 161.37 0.47 1.02 1.17 1.21 0.47 0.75 0.99 9900 0.53 124.8 0.59 1.30 1.59 1.66 0.62 0.97 1.34
10200 0.37 181.82 0.44 0.95 1.09 1.14 0.42 0.67 0.91 10200 0.48 140.5 0.54 1.20 1.49 1.57 0.56 0.88 1.21
10500 0.34 204.08 0.40 0.88 1.02 1.07 0.61 0.82 10500 0.44 158.0 0.51 1.12 1.39 1.48 0.51 0.79 1.09
10800 0.32 228.57 0.82 0.95 1.02 0.55 0.75 10800 0.41 176.9 0.47 1.04 1.30 1.40 0.46 0.72 0.99
11100 0.29 255.17 0.77 0.89 0.96 0.50 0.68 11100 0.38 197.3 0.44 0.97 1.21 1.32 0.42 0.65 0.90
11400 0.27 283.58 0.72 0.84 0.90 0.45 0.63 11400 0.35 219.7 0.41 0.90 1.14 1.25 0.59 0.82
11700 0.25 314.52 0.67 0.78 0.85 0.41 0.57 11700 0.32 243.8 0.84 1.07 1.18 0.54 0.74
12000 0.23 347.83 0.62 0.74 0.80 0.53 12000 0.30 269.4 0.78 1.00 1.11 0.49 0.68

12300 0.21 384.98 0.58 0.69 0.75 0.48 12300 0.28 297.1 0.73 0.94 1.04 0.45 0.62
12600 0.20 422.11 0.54 0.65 0.71 0.44 12600 0.26 326.8 0.69 0.88 0.98 0.41 0.57
12900 0.19 464.86 0.51 0.62 0.67 0.40 12900 0.24 359.8 0.64 0.83 0.92 0.53
13200 0.22 394.6 0.60 0.78 0.87 0.48
13500 0.21 430.6 0.57 0.74 0.82 0.45
13800 0.20 471.8 0.53 0.70 0.78 0.41

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

www.fielders.com.au 79
FINISH ON TOP WITH FIELDERS
10.34

Three Lapped Spans end span


overall purlin length =
span + 70mm + lap end span
PURLIN & GIRT DESIGN MANUAL

200Z
Limit State Capacity Tables span (mm) span (mm) span (mm)
lap overall purlin length =
span + 70mm + (lap/2)

200Z15 200Z19
Bridging (kN/m) Bridging (kN/m)
Span Span
L /150 k Inward Outward k Inward Outward
(mm) (mm) L /150
0 1 2,3 0 1 2 3 0 1 2 3 0 1 2 3

3000 24.51 0.8 8.52 8.53 3000 32.66 0.6 13.74 15.94 15.94
3300 18.41 1.2 7.58 7.57 3300 24.54 0.9 10.84 13.99 13.99
3600 14.18 1.7 6.78 6.78 3600 18.90 1.3 8.75 12.37 12.37
3900 11.16 2.3 5.64 6.11 6.11 3900 14.87 1.7 7.21 11.01 11.01
4200 8.93 3.1 4.71 5.53 5.53 4200 11.90 2.4 6.02 9.78 9.13 9.78
4500 7.26 4.1 3.99 5.03 5.03 4500 9.68 3.1 5.06 8.52 7.47 8.52
4800 5.98 5.3 3.42 4.59 4.34 4.59 4800 7.97 4.0 4.32 7.49 5.91 7.49
5100 4.99 6.8 2.96 4.21 3.56 4.21 5100 6.65 5.1 3.73 6.64 4.91 6.64
5400 4.20 8.6 2.58 3.87 2.94 3.87 5400 5.60 6.4 3.24 5.92 4.13 5.92
5700 3.57 10.6 2.27 3.56 2.46 3.56 5700 4.76 8.0 2.85 5.31 3.50 5.31
6000 3.06 13.1 2.01 3.22 2.07 3.22 6000 4.08 9.8 2.52 4.79 2.99 4.74
6300 2.65 15.9 1.79 2.92 1.76 2.89 6300 3.53 11.9 2.24 4.35 2.53 4.15 4.35
6600 2.30 19.1 1.60 2.66 1.47 2.56 2.66 6600 3.07 14.3 2.01 3.96 2.16 3.65 3.96
6900 2.01 22.8 1.40 2.43 1.28 2.27 2.43 6900 2.68 17.1 1.81 3.63 1.86 3.21 3.63
7200 1.77 27.1 1.27 2.23 1.12 1.98 2.23 7200 2.36 20.3 1.63 3.30 1.60 2.79 3.33
7500 1.57 31.9 1.15 2.06 0.98 1.73 2.06 7500 2.09 23.9 1.47 3.00 3.07 1.38 2.38 3.07
7800 1.40 37.3 1.05 1.90 0.87 1.52 1.90 7800 1.86 28.0 1.34 2.74 2.84 1.19 2.11 2.84
8100 1.25 43.4 0.96 1.77 0.76 1.34 1.77 8100 1.66 32.5 1.22 2.51 2.63 1.04 1.88 2.60
8400 1.12 50.2 0.88 1.64 0.67 1.18 1.63 8400 1.49 37.6 1.11 2.31 2.45 0.91 1.68 2.35 2.45
8700 1.01 57.7 0.81 1.53 0.59 1.05 1.49 1.53 8700 1.34 43.3 1.02 2.13 2.28 0.80 1.51 2.13 2.28
9000 0.91 66.1 0.75 1.43 0.52 0.94 1.36 1.43 9000 1.21 49.6 0.94 1.97 2.13 0.71 1.36 1.94 2.13
9300 0.82 75.3 0.69 1.34 0.46 0.84 1.24 1.34 9300 1.10 56.6 0.86 1.82 2.00 0.63 1.22 1.76 2.00
9600 0.75 85.6 0.64 1.25 0.41 0.75 1.12 1.26 9600 1.00 64.2 0.80 1.69 1.87 0.56 1.09 1.59 1.88
9900 0.68 96.8 0.59 1.17 0.66 1.01 1.18 9900 0.91 72.6 0.74 1.57 1.76 0.50 0.98 1.39 1.75
10200 0.62 109.0 0.55 1.09 0.60 0.92 1.12 10200 0.83 81.8 0.68 1.46 1.66 0.45 0.89 1.27 1.62
10500 0.57 122.4 0.51 1.02 1.05 0.55 0.83 1.04 10500 0.76 91.9 0.63 1.36 1.57 0.41 0.80 1.16 1.49
10800 0.53 137.1 0.47 0.96 0.99 0.50 0.76 0.96 10800 0.70 102.9 0.59 1.27 1.48 0.73 1.07 1.38
11100 0.48 152.9 0.44 0.90 0.94 0.46 0.69 0.90 11100 0.65 114.7 0.55 1.18 1.40 0.66 0.98 1.28
11400 0.45 170.0 0.41 0.85 0.89 0.42 0.63 0.83 11400 0.60 127.7 0.51 1.11 1.33 0.59 0.90 1.18
11700 0.41 188.9 0.80 0.85 0.58 0.77 11700 0.55 141.6 0.48 1.03 1.26 0.54 0.83 1.09
12000 0.38 208.9 0.75 0.80 0.53 0.71 12000 0.51 156.9 0.45 0.94 1.20 0.49 0.77 1.00

12300 0.36 230.3 0.70 0.77 0.49 0.65 12300 0.47 173.0 0.42 0.89 1.14 0.45 0.71 0.90
12600 0.33 253.8 0.66 0.73 0.45 0.60 12600 0.44 190.5 0.84 1.09 0.41 0.65 0.83
12900 0.31 279.2 0.62 0.70 0.40 0.55 12900 0.41 209.2 0.79 1.03 0.60 0.77
13200 0.29 305.6 0.58 0.67 0.51 13200 0.38 229.8 0.74 0.97 0.56 0.72
13500 0.27 334.6 0.54 0.64 0.48 13500 0.36 251.4 0.70 0.92 0.95 0.51 0.67
13800 0.25 365.1 0.51 0.61 0.44 13800 0.34 273.8 0.66 0.87 0.91 0.48 0.63
14100 0.24 398.3 0.48 0.58 0.41 14100 0.32 298.4 0.63 0.82 0.87 0.44 0.59
14400 0.30 325.4 0.60 0.78 0.83 0.41 0.55

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

80 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15
10.34
overall purlin length =
end span span + 70mm + lap end span

PURLIN & GIRT DESIGN MANUAL


Three Lapped Spans
200Z
Limit State Capacity Tables span (mm) span (mm) span (mm)
lap overall purlin length =
span + 70mm + (lap/2)

200Z24
Bridging (kN/m)
Span
k Inward Outward
(mm) L /150
0 1 2 3 0 1 2 3

4500 12.26 2.4 5.96 11.95 10.12 11.95


4800 10.10 3.2 5.05 10.50 8.34 10.50
5100 8.42 4.0 4.33 9.23 6.82 9.30
5400 7.09 5.1 3.75 8.10 8.30 5.63 8.16
5700 6.03 6.3 3.28 7.17 7.45 4.71 7.13 7.45
6000 5.17 7.7 2.89 6.37 6.72 3.97 6.26 6.72
6300 4.47 9.4 2.57 5.70 6.10 3.34 5.52 6.10
6600 3.89 11.3 2.29 5.13 5.55 2.83 4.89 5.55
6900 3.40 13.5 2.06 4.63 5.08 2.41 4.34 5.08
7200 2.99 16.0 1.86 4.20 4.67 2.07 3.83 4.62
7500 2.65 18.9 1.68 3.83 4.30 1.79 3.39 4.17 4.31
7800 2.35 22.1 1.53 3.50 3.98 1.56 2.97 3.78 3.98
8100 2.10 25.7 1.40 3.21 3.69 1.36 2.61 3.43 3.69
8400 1.88 29.7 1.28 2.95 3.43 1.20 2.31 3.13 3.43
8700 1.70 34.2 1.18 2.72 3.20 1.06 2.05 2.85 3.20
9000 1.53 39.2 1.08 2.51 2.99 0.94 1.83 2.61 2.94
9300 1.39 44.6 1.00 2.32 2.79 0.83 1.64 2.39 2.71
9600 1.26 50.7 0.93 2.15 2.60 0.75 1.46 2.17 2.50
9900 1.15 57.3 0.86 2.00 2.43 0.67 1.31 1.98 2.31
10200 1.05 64.6 0.80 1.86 2.27 2.33 0.60 1.17 1.80 2.14
10500 0.97 72.5 0.75 1.73 2.13 2.20 0.55 1.05 1.63 1.99
10800 0.89 81.2 0.70 1.62 2.00 2.08 0.50 0.95 1.48 1.85
11100 0.82 90.6 0.65 1.51 1.88 1.97 0.45 0.86 1.35 1.72
11400 0.75 100.8 0.61 1.41 1.77 1.86 0.41 0.78 1.23 1.60
11700 0.70 111.9 0.57 1.32 1.67 1.77 0.71 1.13 1.48
12000 0.65 123.8 0.54 1.24 1.58 1.68 0.65 1.04 1.37

12300 0.60 136.7 0.50 1.16 1.49 1.60 0.59 0.96 1.28
12600 0.56 150.5 0.47 1.09 1.41 1.51 0.54 0.88 1.18
12900 0.52 165.4 0.45 1.03 1.34 1.44 0.50 0.81 1.09
13200 0.49 181.1 0.42 0.97 1.27 1.37 0.46 0.74 1.01
13500 0.45 198.2 0.91 1.20 1.30 0.42 0.68 0.93
13800 0.43 216.5 0.86 1.14 1.24 0.63 0.87
14100 0.40 236.2 0.82 1.08 1.18 0.58 0.80
14400 0.37 256.7 0.77 1.03 1.13 0.54 0.75
14700 0.35 278.4 0.73 0.98 1.08 0.50 0.70
15000 0.33 302.1 0.69 0.93 1.03 0.46 0.65
15300 0.31 326.9 0.66 0.89 0.98 0.43 0.61
15600 0.29 353.7 0.63 0.84 0.94 0.40 0.57
15900 0.28 381.3 0.60 0.80 0.89 0.53
16200 0.26 410.6 0.57 0.76 0.85 0.50
16500 0.25 441.8 0.54 0.72 0.82 0.46
16800 0.24 474.6 0.51 0.69 0.78 0.43
17100 0.22 511.2 0.49 0.65 0.74 0.41

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

www.fielders.com.au 81
FINISH ON TOP WITH FIELDERS
10.35

Three Lapped Spans end span


overall purlin length =
span + 70mm + lap end span
PURLIN & GIRT DESIGN MANUAL

250Z
Limit State Capacity Tables span (mm) span (mm) span (mm)
lap overall purlin length =
span + 70mm + (lap/2)

250Z19
Bridging (kN/m)
Span
k Inward Outward
(mm) L /150
0 1 2 3 0 1 2 3

3600 31.08 0.8 10.88 11.32 11.32


3900 24.45 1.1 8.93 10.24 10.24
4200 19.57 1.4 7.46 9.31 9.31
4500 15.92 1.9 6.27 8.51 8.51
4800 13.11 2.4 5.34 7.80 7.61 7.80
5100 10.93 3.1 4.59 7.18 6.29 7.18
5400 9.21 3.9 3.99 6.63 5.25 6.63
5700 7.83 4.9 3.50 6.14 4.43 6.14
6000 6.71 6.0 3.09 5.70 3.76 5.70
6300 5.80 7.2 2.75 5.30 3.20 5.30
6600 5.05 8.7 2.46 4.84 2.71 4.78
6900 4.42 10.4 2.21 4.43 2.32 4.15 4.43
7200 3.89 12.4 1.99 4.07 2.00 3.60 4.07
7500 3.44 14.5 1.81 3.75 1.74 3.06 3.75
7800 3.06 17.0 1.65 3.47 1.51 2.70 3.47
8100 2.73 19.8 1.50 3.22 1.31 2.39 3.22
8400 2.45 22.9 1.38 2.99 1.15 2.13 2.99
8700 2.20 26.3 1.26 2.76 1.01 1.90 2.78
9000 1.99 30.2 1.16 2.55 0.89 1.71 2.53 2.61
9300 1.80 34.4 1.07 2.36 2.44 0.79 1.54 2.27 2.44
9600 1.64 39.0 0.99 2.18 2.29 0.70 1.38 2.04 2.29
9900 1.50 44.1 0.91 2.01 2.15 0.63 1.24 1.79 2.16
10200 1.37 49.7 0.84 1.87 2.03 0.56 1.11 1.63 2.03
10500 1.25 55.9 0.78 1.73 1.91 0.51 1.00 1.48 1.92
10800 1.15 62.6 0.73 1.61 1.81 0.46 0.91 1.36 1.80
11100 1.06 69.8 0.68 1.46 1.71 0.41 0.82 1.24 1.67
11400 0.98 77.6 0.63 1.36 1.62 0.75 1.14 1.53
11700 0.91 86.2 0.59 1.28 1.54 0.68 1.05 1.40
12000 0.84 95.4 0.55 1.20 1.47 0.62 0.97 1.25

12300 0.78 105.3 0.51 1.13 1.39 0.57 0.89 1.15


12600 0.73 115.9 0.48 1.06 1.33 0.52 0.82 1.07
12900 0.68 127.2 0.45 1.00 1.27 0.47 0.76 0.99
13200 0.63 139.5 0.42 0.94 1.21 0.43 0.70 0.92
13500 0.59 152.8 0.89 1.16 0.64 0.85
13800 0.55 166.7 0.84 1.11 0.60 0.80
14100 0.52 181.8 0.79 1.06 0.55 0.74
14400 0.49 197.5 0.75 1.01 0.51 0.69
14700 0.46 214.4 0.71 0.96 0.48 0.65
15000 0.43 232.6 0.67 0.91 0.94 0.44 0.61
15300 0.41 251.9 0.64 0.85 0.90 0.41 0.57
15600 0.38 272.3 0.60 0.81 0.87 0.54
15900 0.36 293.6 0.57 0.76 0.84 0.50
16200 0.34 316.7 0.55 0.72 0.81 0.47
16500 0.32 340.6 0.52 0.66 0.78 0.44
16800 0.31 366.0 0.49 0.62 0.75 0.41

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

82 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15
10.35
overall purlin length =
end span span + 70mm + lap end span

PURLIN & GIRT DESIGN MANUAL


Three Lapped Spans
250Z
Limit State Capacity Tables span (mm) span (mm) span (mm)
lap overall purlin length =
span + 70mm + (lap/2)

250Z24
Bridging (kN/m)
Span
k Inward Outward
(mm) L /150
0 1 2 3 0 1 2 3

5700 10.23 3.7 4.05 9.54 6.15 9.54


6000 8.77 4.6 3.57 8.55 5.13 8.45
6300 7.58 5.5 3.16 7.64 7.81 4.30 7.44 7.81
6600 6.59 6.7 2.82 6.85 7.12 3.63 6.56 7.12
6900 5.77 8.0 2.53 6.18 6.51 3.09 5.79 6.51
7200 5.08 9.5 2.28 5.60 5.98 2.65 5.08 5.98
7500 4.49 11.1 2.06 5.09 5.51 2.28 4.43 5.51
7800 3.99 13.0 1.88 4.65 5.10 1.98 3.87 5.10
8100 3.57 15.1 1.71 4.25 4.73 1.73 3.40 4.63 4.73
8400 3.20 17.5 1.57 3.89 4.39 1.51 3.01 4.21 4.40
8700 2.88 20.2 1.44 3.56 4.10 1.33 2.67 3.83 4.10
9000 2.60 23.1 1.32 3.28 3.83 1.18 2.38 3.50 3.83
9300 2.36 26.3 1.22 3.03 3.59 1.05 2.11 3.18 3.59
9600 2.14 29.9 1.13 2.79 3.36 0.93 1.87 2.88 3.37
9900 1.95 33.8 1.05 2.58 3.16 0.84 1.67 2.61 3.12
10200 1.79 38.1 0.97 2.39 2.98 0.75 1.50 2.35 2.89
10500 1.64 42.8 0.91 2.22 2.81 0.68 1.35 2.13 2.68
10800 1.50 47.9 0.85 2.06 2.66 0.61 1.21 1.93 2.48
11100 1.39 53.4 0.79 1.92 2.52 0.56 1.10 1.76 2.30
11400 1.28 59.4 0.74 1.79 2.38 0.51 0.99 1.61 2.13
11700 1.18 65.9 0.69 1.68 2.24 0.46 0.90 1.47 1.97
12000 1.10 72.9 0.65 1.57 2.11 2.16 0.42 0.82 1.35 1.82

12300 1.02 80.6 0.61 1.48 2.00 2.05 0.75 1.23 1.67
12600 0.95 88.7 0.57 1.39 1.89 1.96 0.69 1.13 1.54
12900 0.88 97.4 0.54 1.31 1.79 1.87 0.63 1.03 1.42
13200 0.82 106.8 0.51 1.23 1.69 1.78 0.58 0.95 1.31
13500 0.77 116.9 0.48 1.16 1.60 1.70 0.53 0.87 1.22
13800 0.72 127.6 0.45 1.10 1.52 1.63 0.49 0.81 1.13
14100 0.68 139.1 0.43 1.04 1.44 1.56 0.45 0.74 1.05
14400 0.64 151.2 0.40 0.98 1.37 1.50 0.42 0.69 0.98
14700 0.60 164.4 0.93 1.30 1.44 0.64 0.91
15000 0.56 178.3 0.88 1.23 1.38 0.59 0.84
15300 0.53 192.8 0.84 1.17 1.32 0.55 0.79
15600 0.50 208.4 0.79 1.10 1.26 0.51 0.73
15900 0.47 225.1 0.75 1.05 1.20 0.48 0.68
16200 0.45 242.2 0.71 0.99 1.15 0.44 0.64
16500 0.42 260.7 0.68 0.94 1.09 0.41 0.59
16800 0.40 280.0 0.64 0.89 1.04 0.56
17100 0.38 300.8 0.61 0.84 1.00 0.52
17400 0.36 322.2 0.58 0.80 0.95 0.49
17700 0.34 345.0 0.55 0.75 0.91 0.46
18000 0.33 369.2 0.53 0.72 0.87 0.43

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

www.fielders.com.au 83
FINISH ON TOP WITH FIELDERS
10.36

Four Lapped Spans end span


lap
end span
PURLIN & GIRT DESIGN MANUAL

100Z
span (mm) span (mm) span (mm) span (mm)
Limit State Capacity Tables overall purlin length = overall purlin length =
span + 70mm + (lap) span + 70mm + (lap/2)

100Z10 100Z12
Bridging (kN/m) Bridging (kN/m)
Span Span
k Inward Outward k Inward Outward
(mm) L /150 (mm) L /150
0 1,2,3 0 1 2 3 0 1 2 3 0 1 2 3

2100 7.37 1.9 5.42 5.42 2100 9.35 1.5 7.19 8.00 8.00
2400 4.94 3.2 4.45 4.45 2400 6.26 2.6 5.38 6.14 5.84 6.14
2700 3.47 5.2 3.62 3.72 3.43 3.72 2700 4.40 4.1 4.16 4.85 4.18 4.85
3000 2.53 7.9 2.86 3.04 2.45 3.04 3000 3.21 6.2 3.30 3.93 3.10 3.93
3300 1.90 11.6 2.31 2.51 1.79 2.51 3300 2.41 9.1 2.67 3.25 2.33 3.25
3600 1.46 16.4 1.88 2.11 1.34 2.11 3600 1.86 12.9 2.18 2.73 1.79 2.63 2.73
3900 1.15 22.6 1.54 1.80 1.03 1.71 1.80 3900 1.46 17.8 1.81 2.32 1.37 2.07 2.32
4200 0.92 30.4 1.28 1.55 0.82 1.37 1.55 4200 1.17 24.0 1.52 2.00 1.06 1.70 2.00
4500 0.75 40.1 1.08 1.35 0.66 1.09 1.35 4500 0.95 31.6 1.29 1.75 0.83 1.39 1.75
4800 0.62 51.9 0.92 1.19 0.52 0.88 1.19 4800 0.78 40.9 1.11 1.54 0.66 1.14 1.48 1.54
5100 0.52 66.0 0.78 1.05 0.42 0.72 1.01 1.05 5100 0.65 52.1 0.96 1.36 0.53 0.95 1.22 1.36
5400 0.43 82.9 0.67 0.94 0.59 0.86 0.94 5400 0.55 65.5 0.83 1.21 0.43 0.79 1.05 1.21
5700 0.37 103.0 0.58 0.84 0.49 0.72 0.84 5700 0.47 81.4 0.73 1.09 0.66 0.91 1.07
6000 0.32 126.6 0.51 0.76 0.42 0.61 0.76 6000 0.40 99.8 0.64 0.98 0.55 0.78 0.94
6300 0.27 153.8 0.44 0.69 0.52 0.66 6300 0.35 121.4 0.56 0.87 0.47 0.67 0.80
6600 0.24 185.7 0.63 0.44 0.58 6600 0.30 146.2 0.49 0.78 0.81 0.58 0.71
6900 0.21 221.2 0.57 0.51 6900 0.26 174.2 0.44 0.68 0.74 0.51 0.63
7200 0.18 262.3 0.52 0.44 7200 0.23 206.9 0.61 0.68 0.44 0.56
7500 0.21 243.9 0.56 0.63 0.49
7800 0.18 285.7 0.50 0.57 0.58 0.44

100Z24
Bridging (kN/m)
Span
k Inward Outward
(mm) L /150
0 1 2 3 0 1 2 3

2100 18.96 0.7 13.45 17.65 17.53


2400 12.70 1.3 9.80 13.52 12.44 13.52
2700 8.92 2.0 7.40 10.68 9.10 10.68
3000 6.50 3.1 5.78 8.65 6.80 8.65
3300 4.89 4.5 4.63 7.15 5.11 7.09
3600 3.76 6.4 3.79 6.01 3.86 5.67 6.01
3900 2.96 8.8 3.15 5.11 2.98 4.59 5.11
4200 2.37 11.8 2.66 4.39 2.35 3.76 4.41
4500 1.93 15.6 2.27 3.76 3.84 1.88 3.10 3.77
4800 1.59 20.2 1.95 3.26 3.38 1.54 2.58 3.19 3.38
5100 1.32 25.7 1.70 2.84 2.99 1.27 2.13 2.72 2.99
5400 1.12 32.3 1.49 2.50 2.67 1.06 1.76 2.33 2.66
5700 0.95 40.1 1.31 2.21 2.40 0.90 1.47 2.01 2.32
6000 0.81 49.2 1.16 1.97 2.16 0.77 1.24 1.74 2.03
6300 0.70 59.8 1.04 1.76 1.96 0.67 1.06 1.51 1.78
6600 0.61 72.0 0.93 1.58 1.79 0.58 0.91 1.31 1.57
6900 0.54 86.0 0.84 1.42 1.63 0.51 0.79 1.13 1.39
7200 0.47 102.1 0.76 1.29 1.48 0.45 0.68 0.98 1.24
7500 0.42 120.2 0.68 1.17 1.34 1.38 0.60 0.86 1.10
7800 0.37 140.5 0.62 1.07 1.22 1.28 0.53 0.75 0.98
8100 0.33 163.6 0.57 0.97 1.11 1.19 0.47 0.66 0.88
8400 0.30 189.2 0.52 0.89 1.01 1.10 0.42 0.59 0.78
8700 0.27 217.2 0.48 0.82 0.93 1.01 0.52 0.69
9000 0.24 249.0 0.44 0.75 0.85 0.93 0.47 0.62
9300 0.22 284.4 0.40 0.69 0.78 0.85 0.42 0.55
9600 0.20 323.2 0.64 0.72 0.79 0.50
9900 0.18 364.6 0.59 0.67 0.73 0.45
10200 0.17 412.1 0.54 0.62 0.67 0.41

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

84 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15
10.36
lap
end span end span

PURLIN & GIRT DESIGN MANUAL


Four Lapped Spans
100Z
span (mm) span (mm) span (mm) span (mm)
Limit State Capacity Tables overall purlin length = overall purlin length =
span + 70mm + (lap) span + 70mm + (lap/2)

100Z15 100Z19
Bridging (kN/m) Bridging (kN/m)
Span Span
k Inward Outward k Inward Outward
(mm) L /150 (mm) L /150
0 1 2 3 0 1 2 3 0 1 2 3 0 1 2 3

2100 11.92 1.2 9.16 10.28 10.28 2100 15.07 0.9 11.12 13.80 13.62
2400 7.99 2.0 6.80 7.87 7.54 7.87 2400 10.09 1.6 8.20 10.57 9.76 10.57
2700 5.61 3.2 5.24 6.22 5.58 6.22 2700 7.09 2.5 6.22 8.35 7.14 8.35
3000 4.09 4.9 4.14 5.04 4.18 5.04 3000 5.17 3.9 4.85 6.76 5.30 6.76
3300 3.07 7.2 3.33 4.16 3.11 4.16 3300 3.88 5.7 3.87 5.59 3.90 5.49
3600 2.37 10.1 2.72 3.50 2.31 3.39 3.50 3600 2.99 8.0 3.16 4.70 2.92 4.42 4.70
3900 1.86 14.0 2.25 2.98 1.75 2.78 2.98 3900 2.35 11.1 2.61 4.00 2.23 3.59 4.00
4200 1.49 18.8 1.88 2.57 1.36 2.28 2.57 4200 1.88 14.9 2.19 3.45 1.74 2.93 3.45
4500 1.21 24.8 1.59 2.24 1.07 1.88 2.23 4500 1.53 19.6 1.86 3.00 1.39 2.40 2.92 3.00
4800 1.00 32.1 1.36 1.97 0.86 1.55 1.91 1.97 4800 1.26 25.4 1.60 2.60 1.12 1.97 2.48 2.64
5100 0.83 40.9 1.16 1.74 0.70 1.27 1.64 1.74 5100 1.05 32.3 1.38 2.27 2.34 0.92 1.60 2.13 2.34
5400 0.70 51.4 1.01 1.55 0.57 1.04 1.41 1.55 5400 0.89 40.6 1.20 2.00 2.09 0.76 1.32 1.82 2.06
5700 0.60 63.8 0.88 1.38 0.48 0.86 1.22 1.38 5700 0.75 50.5 1.05 1.77 1.87 0.64 1.10 1.56 1.80
6000 0.51 78.3 0.77 1.23 1.26 0.40 0.71 1.05 1.21 6000 0.65 61.9 0.93 1.58 1.69 0.54 0.92 1.35 1.58
6300 0.44 95.0 0.67 1.10 1.14 0.60 0.91 1.07 6300 0.56 75.3 0.82 1.41 1.53 0.46 0.78 1.16 1.39
6600 0.38 114.6 0.60 0.99 1.04 0.51 0.78 0.95 6600 0.49 90.7 0.73 1.27 1.40 0.40 0.66 0.99 1.23
6900 0.34 136.9 0.53 0.90 0.95 0.44 0.67 0.84 6900 0.43 108.2 0.65 1.14 1.27 0.57 0.85 1.08
7200 0.30 162.2 0.47 0.81 0.87 0.58 0.75 7200 0.37 128.3 0.58 1.03 1.15 1.17 0.49 0.74 0.96
7500 0.26 190.8 0.42 0.74 0.80 0.50 0.67 7500 0.33 151.1 0.53 0.93 1.04 1.08 0.43 0.64 0.85
7800 0.23 223.2 0.67 0.73 0.75 0.43 0.59 7800 0.29 176.9 0.47 0.85 0.95 1.00 0.56 0.75
8100 0.21 259.6 0.61 0.66 0.69 0.52 8100 0.26 205.3 0.43 0.77 0.86 0.93 0.49 0.66
8400 0.19 301.1 0.55 0.61 0.64 0.46 8400 0.24 238.3 0.70 0.79 0.85 0.43 0.58
8700 0.17 345.2 0.50 0.56 0.59 0.41 8700 0.21 273.6 0.64 0.72 0.78 0.52
9000 0.19 314.1 0.59 0.66 0.72 0.46
9300 0.17 358.4 0.54 0.61 0.66 0.41

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

www.fielders.com.au 85
FINISH ON TOP WITH FIELDERS
10.37

Four Lapped Spans end span


lap
end span
PURLIN & GIRT DESIGN MANUAL

150Z
span (mm) span (mm) span (mm) span (mm)
Limit State Capacity Tables overall purlin length = overall purlin length =
span + 70mm + (lap) span + 70mm + (lap/2)

150Z12 150Z15
Bridging (kN/m) Bridging (kN/m)
Span Span
L /150 k Inward Outward k Inward Outward
(mm) (mm) L /150
0 1 2,3 0 1 2 3 0 1 2 3 0 1 2 3

3000 10.02 2.0 5.38 5.38 3000 12.77 1.6 7.39 8.60 8.60
3300 7.53 2.9 4.73 4.73 3300 9.59 2.3 5.81 7.39 7.39
3600 5.80 4.1 4.19 4.19 3600 7.39 3.2 4.76 6.38 6.01 6.38
3900 4.56 5.7 3.48 3.73 3.73 3900 5.81 4.5 3.96 5.48 4.83 5.48
4200 3.65 7.7 2.92 3.34 3.12 3.34 4200 4.65 6.0 3.34 4.72 3.85 4.72
4500 2.97 10.1 2.48 3.01 2.49 3.01 4500 3.78 7.9 2.86 4.11 3.07 4.11
4800 2.45 13.1 2.13 2.72 2.02 2.72 4800 3.12 10.3 2.47 3.62 2.53 3.62
5100 2.04 16.7 1.85 2.47 1.65 2.47 5100 2.60 13.1 2.15 3.20 2.11 3.17
5400 1.72 21.0 1.61 2.25 1.37 2.24 5400 2.19 16.4 1.89 2.86 1.76 2.72 2.86
5700 1.46 26.0 1.42 2.02 1.14 1.94 2.02 5700 1.86 20.4 1.67 2.56 1.46 2.35 2.56
6000 1.25 31.9 1.25 1.82 0.96 1.66 1.82 6000 1.60 25.1 1.48 2.32 1.21 2.04 2.32
6300 1.08 38.8 1.11 1.65 0.82 1.42 1.65 6300 1.38 30.5 1.32 2.10 1.02 1.75 2.10
6600 0.94 46.8 0.99 1.51 0.70 1.21 1.51 6600 1.20 36.7 1.18 1.91 0.86 1.48 1.91
6900 0.82 55.9 0.89 1.38 0.59 1.05 1.38 6900 1.05 43.9 1.06 1.75 0.74 1.30 1.72
7200 0.73 66.2 0.80 1.27 0.51 0.91 1.26 7200 0.92 51.9 0.95 1.61 0.63 1.14 1.53 1.61
7500 0.64 78.0 0.72 1.17 0.44 0.79 1.13 1.17 7500 0.82 61.2 0.86 1.48 0.54 1.01 1.37 1.48
7800 0.57 91.2 0.66 1.08 0.69 1.01 1.08 7800 0.73 71.6 0.78 1.35 0.47 0.90 1.23 1.37
8100 0.51 106.1 0.59 1.00 0.61 0.89 1.00 8100 0.65 83.2 0.70 1.24 1.27 0.41 0.79 1.10 1.27
8400 0.46 122.8 0.54 0.93 0.54 0.79 0.93 8400 0.58 96.2 0.64 1.14 1.18 0.70 0.98 1.17
8700 0.41 141.1 0.49 0.87 0.48 0.71 0.87 8700 0.52 110.9 0.59 1.05 1.10 0.62 0.86 1.07
9000 0.37 161.7 0.45 0.81 0.43 0.63 0.80 9000 0.47 126.8 0.54 0.97 1.03 0.54 0.78 0.97
9300 0.34 184.5 0.42 0.75 0.56 0.73 9300 0.43 144.5 0.49 0.89 0.96 0.48 0.70 0.89
9600 0.31 209.2 0.70 0.51 0.67 9600 0.39 164.1 0.45 0.83 0.90 0.43 0.64 0.81
9900 0.28 236.6 0.65 0.67 0.46 0.61 9900 0.36 185.9 0.41 0.77 0.85 0.58 0.75
10200 0.26 266.7 0.60 0.63 0.41 0.55 10200 0.33 209.2 0.71 0.80 0.53 0.68
10500 0.23 299.1 0.56 0.60 0.50 10500 0.30 234.9 0.66 0.76 0.49 0.62
10800 0.22 334.9 0.52 0.56 0.45 10800 0.27 262.8 0.62 0.71 0.44 0.56
11100 0.20 373.7 0.48 0.53 0.42 11100 0.25 293.7 0.57 0.66 0.68 0.40 0.51
11400 0.23 326.2 0.53 0.62 0.64 0.47
11700 0.22 362.8 0.50 0.58 0.61 0.44
12000 0.20 402.0 0.46 0.54 0.58 0.40

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

86 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15
10.37
lap
end span end span

PURLIN & GIRT DESIGN MANUAL


Four Lapped Spans
150Z
span (mm) span (mm) span (mm) span (mm)
Limit State Capacity Tables overall purlin length = overall purlin length =
span + 70mm + (lap) span + 70mm + (lap/2)

150Z19 150Z24
Bridging (kN/m) Bridging (kN/m)
Span Span
k Inward Outward k Inward Outward
(mm) L /150 (mm) L /150
0 1 2 3 0 1 2 3 0 1 2 3 0 1 2 3

3000 16.12 1.2 9.16 12.46 12.43 3000 20.83 1.0 10.89 17.53 17.18 17.53
3300 12.11 1.8 7.24 10.45 9.84 10.45 3300 15.65 1.4 8.51 14.49 13.44 14.49
3600 9.33 2.6 5.87 8.84 7.90 8.84 3600 12.05 2.0 6.83 12.18 10.68 12.18
3900 7.34 3.5 4.83 7.52 6.42 7.52 3900 9.48 2.7 5.59 10.37 8.60 10.37
4200 5.88 4.8 4.03 6.49 5.21 6.49 4200 7.59 3.7 4.66 8.95 6.85 8.95
4500 4.78 6.3 3.40 5.65 4.16 5.61 4500 6.17 4.9 3.94 7.79 5.42 7.79
4800 3.94 8.1 2.91 4.97 3.38 4.80 4.97 4800 5.09 6.3 3.37 6.83 4.35 6.63 6.85
5100 3.28 10.4 2.52 4.39 2.76 4.13 4.40 5100 4.24 8.0 2.91 5.95 3.53 5.67 6.06
5400 2.76 13.0 2.19 3.87 2.26 3.57 3.93 5400 3.57 10.1 2.54 5.22 5.41 2.90 4.88 5.41
5700 2.35 16.2 1.92 3.44 3.52 1.87 3.11 3.52 5700 3.04 12.5 2.24 4.61 4.85 2.41 4.22 4.85
6000 2.02 19.9 1.70 3.07 3.18 1.56 2.72 3.16 6000 2.60 15.4 1.98 4.10 4.38 2.02 3.67 4.38
6300 1.74 24.1 1.51 2.75 2.88 1.31 2.38 2.81 2.88 6300 2.25 18.7 1.76 3.67 3.97 1.71 3.20 3.89 3.97
6600 1.51 29.1 1.35 2.49 2.63 1.11 2.06 2.50 2.63 6600 1.96 22.5 1.58 3.30 3.62 1.46 2.73 3.45 3.62
6900 1.33 34.7 1.21 2.25 2.40 0.95 1.77 2.24 2.40 6900 1.71 26.9 1.42 2.98 3.31 1.25 2.34 3.07 3.31
7200 1.17 41.2 1.09 2.05 2.21 0.82 1.54 2.01 2.21 7200 1.51 31.9 1.29 2.70 3.04 1.09 2.02 2.75 3.04
7500 1.03 48.4 0.99 1.87 2.04 0.71 1.35 1.81 2.01 7500 1.33 37.5 1.17 2.46 2.80 0.95 1.75 2.46 2.80
7800 0.92 56.7 0.90 1.71 1.88 0.62 1.17 1.64 1.83 7800 1.19 43.9 1.06 2.25 2.59 0.83 1.52 2.21 2.54
8100 0.82 65.9 0.82 1.57 1.75 0.54 1.03 1.48 1.67 8100 1.06 51.0 0.97 2.06 2.40 0.73 1.33 1.99 2.30
8400 0.73 76.3 0.75 1.45 1.62 0.48 0.90 1.33 1.52 8400 0.95 59.0 0.89 1.89 2.24 0.65 1.17 1.80 2.09
8700 0.66 87.7 0.68 1.34 1.51 0.43 0.79 1.20 1.39 8700 0.85 67.9 0.82 1.75 2.08 0.58 1.04 1.59 1.91
9000 0.60 100.5 0.63 1.24 1.41 0.70 1.07 1.28 9000 0.77 77.8 0.76 1.61 1.94 0.52 0.92 1.42 1.74
9300 0.54 114.6 0.58 1.15 1.30 0.62 0.96 1.18 9300 0.70 88.7 0.70 1.49 1.79 0.46 0.82 1.26 1.60
9600 0.49 130.1 0.53 1.07 1.21 1.24 0.56 0.86 1.08 9600 0.64 100.6 0.65 1.39 1.66 1.71 0.42 0.73 1.13 1.46
9900 0.45 147.0 0.49 0.99 1.13 1.17 0.50 0.78 1.00 9900 0.58 113.8 0.60 1.28 1.55 1.61 0.66 1.02 1.35
10200 0.41 165.9 0.46 0.93 1.05 1.10 0.45 0.70 0.92 10200 0.53 128.3 0.56 1.18 1.44 1.52 0.59 0.91 1.24
10500 0.38 186.2 0.42 0.86 0.98 1.04 0.40 0.63 0.84 10500 0.49 144.0 0.52 1.10 1.34 1.43 0.54 0.83 1.13
10800 0.35 208.7 0.80 0.92 0.98 0.57 0.77 10800 0.45 161.4 0.49 1.02 1.25 1.35 0.49 0.75 1.03
11100 0.32 232.7 0.75 0.86 0.92 0.52 0.70 11100 0.41 180.0 0.45 0.94 1.17 1.28 0.44 0.68 0.93
11400 0.29 258.5 0.70 0.80 0.87 0.47 0.64 11400 0.38 200.0 0.42 0.88 1.09 1.21 0.40 0.62 0.85
11700 0.27 286.8 0.65 0.76 0.82 0.43 0.59 11700 0.35 222.2 0.82 1.02 1.13 0.56 0.78
12000 0.25 317.5 0.61 0.71 0.77 0.54 12000 0.33 246.2 0.76 0.96 1.06 0.51 0.71

12300 0.23 350.4 0.57 0.67 0.72 0.50 12300 0.30 271.5 0.71 0.90 1.00 0.47 0.65
12600 0.22 385.3 0.53 0.63 0.68 0.46 12600 0.28 298.9 0.67 0.85 0.94 0.43 0.60
12900 0.20 423.6 0.49 0.59 0.64 0.42 12900 0.26 328.2 0.62 0.80 0.88 0.55
13200 0.25 359.2 0.58 0.75 0.83 0.51
13500 0.23 393.0 0.55 0.71 0.79 0.47
13800 0.21 429.9 0.52 0.67 0.74 0.43
14100 0.20 467.7 0.48 0.63 0.70 0.40

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

www.fielders.com.au 87
FINISH ON TOP WITH FIELDERS
10.38

Four Lapped Spans end span


lap
end span
PURLIN & GIRT DESIGN MANUAL

200Z
span (mm) span (mm) span (mm) span (mm)
Limit State Capacity Tables overall purlin length = overall purlin length =
span + 70mm + (lap) span + 70mm + (lap/2)

200Z15 200Z19
Bridging (kN/m) Bridging (kN/m)
Span Span
L /150 k Inward Outward k Inward Outward
(mm) (mm) L /150
0 1 2,3 0 1 2 3 0 1 2 3 0 1 2 3

3000 26.85 0.7 8.15 8.15 3000 35.78 0.6 13.63 15.02 15.02
3300 20.18 1.1 7.21 7.21 3300 26.88 0.8 10.75 13.11 13.11
3600 15.54 1.5 6.43 6.43 3600 20.71 1.2 8.68 11.55 11.55
3900 12.22 2.1 5.62 5.77 5.77 3900 16.29 1.6 7.15 10.23 10.23
4200 9.79 2.9 4.69 5.21 5.20 4200 13.04 2.1 5.98 9.13 9.13
4500 7.96 3.8 3.97 4.71 4.71 4500 10.60 2.8 5.06 8.18 7.60 8.18
4800 6.56 4.9 3.40 4.29 4.29 4800 8.74 3.7 4.32 7.26 6.28 7.26
5100 5.47 6.2 2.94 3.92 3.70 3.92 5100 7.28 4.7 3.72 6.43 5.03 6.43
5400 4.60 7.8 2.57 3.59 3.07 3.59 5400 6.14 5.9 3.24 5.74 4.23 5.74
5700 3.92 9.7 2.26 3.31 2.56 3.31 5700 5.22 7.3 2.84 5.14 3.59 5.14
6000 3.36 11.9 2.00 3.05 2.16 3.05 6000 4.47 8.9 2.52 4.65 3.07 4.65
6300 2.90 14.5 1.78 2.82 1.84 2.82 6300 3.86 10.9 2.24 4.21 2.65 4.17
6600 2.52 17.4 1.60 2.58 1.57 2.56 6600 3.36 13.1 2.01 3.84 2.26 3.68 3.84
6900 2.21 20.8 1.44 2.36 1.32 2.28 2.36 6900 2.94 15.6 1.81 3.51 1.95 3.25 3.51
7200 1.94 24.7 1.30 2.16 1.16 2.03 2.16 7200 2.59 18.5 1.63 3.23 1.69 2.88 3.23
7500 1.72 29.1 1.15 1.99 1.02 1.80 1.99 7500 2.29 21.8 1.48 2.97 1.47 2.53 2.97
7800 1.53 34.0 1.05 1.84 0.90 1.58 1.84 7800 2.04 25.5 1.35 2.71 1.27 2.17 2.75
8100 1.36 39.6 0.96 1.71 0.80 1.39 1.71 8100 1.82 29.7 1.23 2.48 2.55 1.11 1.93 2.55
8400 1.22 45.8 0.88 1.59 0.71 1.23 1.59 8400 1.63 34.4 1.12 2.28 2.37 0.97 1.73 2.35
8700 1.10 52.7 0.81 1.48 0.62 1.10 1.48 8700 1.47 39.5 1.03 2.10 2.21 0.86 1.55 2.14 2.21
9000 1.00 60.3 0.75 1.39 0.55 0.98 1.36 1.39 9000 1.33 45.3 0.95 1.94 2.07 0.76 1.39 1.95 2.07
9300 0.90 68.8 0.69 1.30 0.49 0.87 1.25 1.30 9300 1.20 51.6 0.88 1.80 1.93 0.68 1.26 1.78 1.93
9600 0.82 78.1 0.64 1.22 0.44 0.78 1.14 1.22 9600 1.09 58.6 0.81 1.67 1.82 0.60 1.14 1.62 1.82
9900 0.75 88.4 0.60 1.14 0.71 1.04 1.14 9900 1.00 66.3 0.75 1.55 1.71 0.54 1.03 1.47 1.71
10200 0.68 99.6 0.56 1.07 0.62 0.94 1.08 10200 0.91 74.7 0.70 1.44 1.61 0.48 0.93 1.33 1.61
10500 0.63 111.8 0.52 1.00 1.02 0.57 0.86 1.02 10500 0.84 83.8 0.65 1.35 1.52 0.44 0.84 1.18 1.49
10800 0.58 125.0 0.48 0.94 0.96 0.52 0.78 0.96 10800 0.77 93.9 0.60 1.25 1.43 0.76 1.08 1.38
11100 0.53 139.6 0.45 0.88 0.91 0.47 0.71 0.89 11100 0.71 104.8 0.56 1.17 1.36 0.69 1.00 1.28
11400 0.49 155.4 0.42 0.83 0.86 0.44 0.65 0.83 11400 0.65 116.6 0.53 1.09 1.29 0.63 0.92 1.19
11700 0.45 172.2 0.78 0.82 0.40 0.59 0.78 11700 0.60 129.4 0.49 1.02 1.22 0.57 0.85 1.10
12000 0.42 190.5 0.73 0.78 0.55 0.72 12000 0.56 143.1 0.46 0.95 1.16 0.52 0.78 1.02

12300 0.39 210.3 0.69 0.74 0.50 0.67 12300 0.52 158.0 0.43 0.87 1.11 0.48 0.72 0.94
12600 0.36 232.0 0.64 0.71 0.46 0.62 12600 0.48 173.9 0.41 0.82 1.05 0.44 0.67 0.87
12900 0.34 254.4 0.60 0.67 0.43 0.57 12900 0.45 191.1 0.77 0.99 0.40 0.62 0.79
13200 0.32 279.4 0.57 0.64 0.53 13200 0.42 209.5 0.73 0.94 0.96 0.58 0.73
13500 0.30 305.1 0.53 0.62 0.49 13500 0.39 229.0 0.69 0.89 0.92 0.53 0.68
13800 0.28 333.3 0.50 0.59 0.45 13800 0.37 250.0 0.65 0.84 0.88 0.49 0.64
14100 0.26 362.9 0.47 0.56 0.42 14100 0.35 272.5 0.61 0.79 0.84 0.46 0.60
14400 0.32 296.3 0.58 0.75 0.81 0.43 0.56
14700 0.30 322.4 0.55 0.71 0.77 0.53
15000 0.29 349.7 0.52 0.67 0.74 0.49
15300 0.27 377.8 0.50 0.64 0.71 0.46
15600 0.25 409.4 0.47 0.60 0.68 0.44
15900 0.24 441.7 0.45 0.57 0.65 0.41

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

88 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15
10.38
lap
end span end span

PURLIN & GIRT DESIGN MANUAL


Four Lapped Spans
200Z
span (mm) span (mm) span (mm) span (mm)
Limit State Capacity Tables overall purlin length = overall purlin length =
span + 70mm + (lap) span + 70mm + (lap/2)

200Z24
Bridging (kN/m)
Span
k Inward Outward
(mm) L /150
0 1 2 3 0 1 2 3

4500 13.43 2.2 6.00 11.57 10.15 11.57


4800 11.07 2.9 5.08 10.17 8.51 10.17
5100 9.23 3.7 4.36 9.01 7.10 9.01
5400 7.77 4.6 3.78 7.99 5.88 8.04
5700 6.61 5.8 3.30 7.06 7.21 4.91 7.09
6000 5.67 7.1 2.91 6.29 6.51 4.14 6.24 6.51
6300 4.89 8.6 2.58 5.63 5.90 3.53 5.51 5.90
6600 4.26 10.3 2.31 5.06 5.38 3.00 4.90 5.38
6900 3.73 12.3 2.07 4.57 4.92 2.56 4.36 4.92
7200 3.28 14.6 1.87 4.15 4.52 2.20 3.89 4.52
7500 2.90 17.2 1.69 3.78 4.17 1.90 3.46 4.13
7800 2.58 20.2 1.54 3.46 3.85 1.66 3.08 3.75 3.85
8100 2.30 23.4 1.41 3.17 3.57 1.45 2.72 3.41 3.57
8400 2.07 27.1 1.29 2.92 3.32 1.28 2.41 3.11 3.32
8700 1.86 31.2 1.19 2.69 3.10 1.13 2.14 2.84 3.10
9000 1.68 35.7 1.09 2.49 2.89 1.00 1.91 2.60 2.89
9300 1.52 40.8 1.01 2.31 2.71 0.89 1.71 2.38 2.68
9600 1.38 46.3 0.94 2.14 2.54 0.80 1.54 2.19 2.48
9900 1.26 52.3 0.87 1.98 2.39 0.72 1.38 2.01 2.29
10200 1.15 59.0 0.81 1.84 2.23 0.65 1.24 1.84 2.13
10500 1.06 66.2 0.76 1.72 2.09 0.58 1.12 1.68 1.98
10800 0.97 74.2 0.71 1.60 1.96 2.01 0.53 1.01 1.53 1.84
11100 0.90 82.7 0.66 1.50 1.84 1.90 0.48 0.91 1.40 1.71
11400 0.83 92.0 0.62 1.40 1.73 1.80 0.44 0.83 1.27 1.60
11700 0.76 102.1 0.58 1.31 1.63 1.71 0.40 0.76 1.17 1.49
12000 0.71 113.0 0.55 1.22 1.54 1.63 0.69 1.07 1.39

12300 0.66 124.6 0.51 1.15 1.45 1.55 0.63 0.99 1.29
12600 0.61 137.3 0.48 1.08 1.37 1.48 0.58 0.91 1.20
12900 0.57 150.9 0.46 1.01 1.30 1.41 0.53 0.84 1.12
13200 0.53 165.4 0.43 0.95 1.23 1.35 0.49 0.77 1.04
13500 0.50 181.1 0.41 0.90 1.16 1.28 0.45 0.71 0.96
13800 0.47 197.4 0.85 1.10 1.21 0.42 0.66 0.89
14100 0.44 215.1 0.80 1.05 1.15 0.61 0.83
14400 0.41 234.1 0.76 0.99 1.10 0.56 0.77
14700 0.39 254.5 0.72 0.94 1.04 0.52 0.72
15000 0.36 275.5 0.68 0.90 0.99 0.49 0.67
15300 0.34 298.2 0.64 0.85 0.94 0.45 0.63
15600 0.32 323.0 0.61 0.81 0.90 0.42 0.59
15900 0.30 348.7 0.58 0.77 0.86 0.55
16200 0.29 375.0 0.55 0.73 0.82 0.52
16500 0.27 404.4 0.53 0.69 0.78 0.48
16800 0.26 434.1 0.50 0.66 0.75 0.45
17100 0.25 465.3 0.48 0.62 0.71 0.43

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

www.fielders.com.au 89
FINISH ON TOP WITH FIELDERS
10.39

Four Lapped Spans end span


lap
end span
PURLIN & GIRT DESIGN MANUAL

250Z
span (mm) span (mm) span (mm) span (mm)
Limit State Capacity Tables overall purlin length = overall purlin length =
span + 70mm + (lap) span + 70mm + (lap/2)

250Z19 250Z24
Bridging (kN/m) Bridging (kN/m)
Span Span
k Inward Outward k Inward Outward
(mm) L /150 (mm) L /150
0 1 2 3 0 1 2 3 0 1 2 3 0 1 2 3

3600 34.06 0.7 10.81 10.81 5700 11.21 3.4 4.08 9.24 6.41 9.24
3900 26.79 1.0 8.87 9.74 9.74 6000 9.61 4.2 3.59 8.34 5.41 8.34
4200 21.45 1.3 7.41 8.83 8.83 6300 8.30 5.1 3.18 7.55 4.56 7.44
4500 17.44 1.7 6.27 8.04 8.04 6600 7.22 6.1 2.84 6.78 3.85 6.59 6.90
4800 14.37 2.2 5.34 7.35 7.35 6900 6.32 7.3 2.54 6.12 6.31 3.28 5.85 6.31
5100 11.98 2.8 4.60 6.74 6.48 6.74 7200 5.56 8.6 2.29 5.54 5.79 2.82 5.20 5.79
5400 10.09 3.6 3.99 6.21 5.42 6.21 7500 4.92 10.2 2.08 5.04 5.34 2.43 4.59 5.34
5700 8.58 4.4 3.50 5.73 4.57 5.73 7800 4.38 11.9 1.89 4.60 4.94 2.11 4.04 4.94
6000 7.36 5.4 3.09 5.31 3.89 5.31 8100 3.91 13.8 1.72 4.21 4.58 1.84 3.55 4.58
6300 6.36 6.6 2.75 4.92 3.33 4.92 8400 3.50 16.0 1.58 3.87 4.26 1.62 3.14 4.19
6600 5.53 8.0 2.46 4.58 2.87 4.58 8700 3.15 18.4 1.45 3.56 3.97 1.42 2.79 3.82 3.97
6900 4.84 9.5 2.21 4.27 2.45 4.25 9000 2.85 21.1 1.34 3.27 3.71 1.26 2.48 3.49 3.71
7200 4.26 11.3 1.99 3.94 2.11 3.74 3.94 9300 2.58 24.0 1.23 3.02 3.47 1.12 2.23 3.20 3.47
7500 3.77 13.3 1.81 3.63 1.83 3.26 3.63 9600 2.35 27.3 1.14 2.79 3.26 1.00 1.99 2.93 3.26
7800 3.35 15.5 1.65 3.36 1.60 2.78 3.36 9900 2.14 30.8 1.06 2.58 3.06 0.90 1.77 2.66 3.06
8100 2.99 18.1 1.50 3.11 1.40 2.47 3.11 10200 1.96 34.8 0.99 2.39 2.89 0.80 1.59 2.43 2.87
8400 2.68 20.9 1.38 2.90 1.23 2.20 2.90 10500 1.79 39.0 0.92 2.22 2.72 0.73 1.43 2.20 2.66
8700 2.41 24.0 1.27 2.70 1.08 1.97 2.70 10800 1.65 43.7 0.86 2.06 2.58 0.66 1.29 2.00 2.47
9000 2.18 27.5 1.17 2.51 0.95 1.76 2.52 11100 1.52 48.7 0.80 1.91 2.44 0.60 1.17 1.82 2.30
9300 1.98 31.4 1.08 2.33 0.85 1.59 2.32 11400 1.40 54.2 0.75 1.79 2.31 0.54 1.06 1.66 2.14
9600 1.80 35.6 1.00 2.16 2.22 0.75 1.43 2.10 2.22 11700 1.30 60.2 0.70 1.67 2.19 0.49 0.96 1.52 1.99
9900 1.64 40.3 0.93 2.00 2.09 0.67 1.30 1.89 2.09 12000 1.20 66.6 0.66 1.56 2.07 0.45 0.88 1.39 1.85
10200 1.50 45.4 0.86 1.85 1.97 0.60 1.17 1.66 1.97
10500 1.37 51.0 0.80 1.72 1.85 0.54 1.05 1.51 1.85 12300 1.12 73.5 0.62 1.46 1.95 0.41 0.80 1.28 1.71
10800 1.26 57.1 0.74 1.60 1.75 0.49 0.95 1.38 1.75 12600 1.04 80.9 0.59 1.37 1.84 1.89 0.73 1.18 1.59
11100 1.16 63.7 0.69 1.49 1.66 0.44 0.87 1.27 1.66 12900 0.97 88.9 0.55 1.29 1.74 1.81 0.67 1.08 1.47
11400 1.07 70.8 0.65 1.34 1.57 0.40 0.79 1.16 1.55 13200 0.90 97.5 0.52 1.21 1.64 1.72 0.62 0.99 1.36
11700 0.99 78.6 0.61 1.25 1.49 0.72 1.07 1.44 13500 0.84 106.6 0.49 1.14 1.55 1.65 0.57 0.91 1.26
12000 0.92 87.0 0.57 1.18 1.42 0.66 0.99 1.32 13800 0.79 116.5 0.47 1.08 1.47 1.58 0.52 0.84 1.16
14100 0.74 126.9 0.44 1.02 1.39 1.51 0.48 0.78 1.08
12300 0.85 96.0 0.53 1.10 1.35 0.60 0.91 1.22 14400 0.70 138.1 0.42 0.96 1.32 1.45 0.45 0.72 1.01
12600 0.79 105.8 0.50 1.04 1.29 0.55 0.84 1.09 14700 0.65 149.8 0.91 1.25 1.39 0.41 0.67 0.94
12900 0.74 116.2 0.47 0.98 1.23 0.50 0.78 1.01 15000 0.62 162.6 0.86 1.18 1.33 0.62 0.88
13200 0.69 127.4 0.44 0.92 1.17 0.46 0.73 0.94 15300 0.58 175.9 0.82 1.12 1.27 0.58 0.82
13500 0.65 139.3 0.42 0.87 1.12 0.42 0.67 0.87 15600 0.55 190.1 0.78 1.06 1.21 0.54 0.76
13800 0.61 152.1 0.82 1.07 0.62 0.81 15900 0.52 205.4 0.74 1.00 1.15 0.50 0.71
14100 0.57 165.8 0.77 1.03 0.57 0.76 16200 0.49 221.3 0.70 0.95 1.10 0.47 0.67
14400 0.53 180.5 0.73 0.97 0.53 0.71 16500 0.46 238.1 0.66 0.89 1.05 0.44 0.62
14700 0.50 196.0 0.69 0.92 0.95 0.49 0.66 16800 0.44 255.7 0.63 0.85 1.00 0.41 0.58
15000 0.47 212.3 0.66 0.87 0.91 0.46 0.62 17100 0.42 274.7 0.60 0.80 0.95 0.54
15300 0.44 229.7 0.62 0.82 0.87 0.43 0.58 17400 0.39 294.4 0.57 0.76 0.91 0.51
15600 0.42 248.2 0.59 0.77 0.84 0.40 0.55 17700 0.37 315.5 0.54 0.72 0.87 0.48
15900 0.40 268.4 0.56 0.73 0.81 0.52 18000 0.36 337.1 0.51 0.68 0.83 0.45
16200 0.37 288.8 0.53 0.66 0.78 0.49
16500 0.35 310.7 0.51 0.63 0.75 0.46
16800 0.34 334.3 0.48 0.60 0.72 0.43
17100 0.32 358.5 0.46 0.57 0.69 0.40

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

90 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15

PURLIN & GIRT DESIGN MANUAL


This page intentionally blank

www.fielders.com.au 91
FINISH ON TOP WITH FIELDERS
10.40
PURLIN & GIRT DESIGN MANUAL

Cantilevers
Limit State Capacity Tables

1000mm 2000mm
Bridging (kN/m) Bridging (kN/m)
Span Span
k Inward Outward k Inward Outward
(mm) L /150 (mm) L /150
0 1 2 0 1 2 0 1 2 0 1 2

75LC 75LC
75LC10 75LC10
2100 2.21 6.3 3.02 3.02 2100 0.10 142.9 0.76 0.76
3000 0.39 50.8 1.73 1.04 1.63 1.70 3000 0.11 190.5 0.76 0.76
3900 0.12 224.1 0.92 0.40 0.67 0.91 3900 0.18 148.6 0.76 0.61 0.76
75LC12 75LC12
2100 2.81 5.0 3.88 3.88 2100 0.12 112.9 0.97 0.97
3000 0.50 40.0 2.04 2.18 1.43 1.96 2.19 3000 0.13 150.4 0.97 0.97
3900 0.15 176.9 1.09 1.17 0.52 0.87 1.09 3900 0.22 117.1 0.89 0.97 0.78 0.97
75LC15 75LC15
2100 3.62 3.9 4.83 4.83 2100 0.16 87.5 1.21 1.21
3000 0.65 31.0 2.62 2.72 1.95 2.65 2.72 3000 0.17 116.3 1.21 1.21
3900 0.19 136.9 1.39 1.46 0.71 1.22 1.46 3900 0.29 90.9 1.16 1.21 1.08 1.21
100LC/100Z 100LC/100Z
100LC10/100Z10 100LC10/100Z10
2100 4.49 3.11 4.09 4.09 2100 0.20 70.4 1.09 1.09
3000 0.80 25.0 2.48 1.65 2.44 3000 0.22 93.4 1.09 1.09
3900 0.24 110.2 1.31 0.60 1.06 1.31 3900 0.36 73.2 1.09 0.95 1.09
4800 0.11 293.6 0.83 0.49 0.77 4800 0.48 67.8 1.03 0.70 1.05
5700 0.06 633.3 0.57 0.43 6000 0.10 400.0 0.62 0.44
100LC12/100Z12 100LC12/100Z12
2100 5.69 2.5 5.61 5.61 2100 0.25 55.5 1.40 1.40
3000 1.01 19.7 3.12 2.18 3.09 3.16 3000 0.27 74.1 1.40 1.40
3900 0.30 87.0 1.66 1.69 0.75 1.35 1.69 3900 0.45 57.9 1.36 1.40 1.19 1.40
4800 0.14 231.9 1.04 1.07 0.66 0.94 4800 0.60 53.5 1.19 1.40 0.50 0.93 1.26
6000 0.06 625.0 0.64 0.66 0.47 6000 0.13 315.0 0.70 0.79 0.57
100LC15/100Z15 100LC15/100Z15
2100 7.28 1.9 7.17 7.17 2100 0.32 43.5 1.79 1.79
3000 1.30 15.4 3.86 4.03 2.80 4.00 3000 0.35 57.8 1.79 1.79
3900 0.38 68.1 2.04 2.16 0.98 1.80 2.16 3900 0.58 45.2 1.72 1.79 1.58 1.79
4800 0.18 181.8 1.28 1.37 0.45 0.84 1.25 4800 0.77 41.8 1.48 1.79 0.66 1.20 1.69
6000 0.08 487.8 0.78 0.85 0.62 6000 0.16 246.9 0.88 1.01 0.45 0.76
100LC19/100Z19 100LC19/100Z19
2100 9.19 1.5 9.35 9.63 9.63 2100 0.41 34.5 2.41 2.41
3000 1.64 12.2 4.68 5.42 3.53 5.21 5.43 3000 0.44 45.8 2.40 2.41
3900 0.48 53.8 2.47 2.91 1.27 2.28 2.88 3900 0.73 35.8 2.15 2.41 2.03 2.41
4800 0.22 144.1 1.54 1.83 0.60 1.07 1.60 4800 0.96 33.2 1.71 2.41 0.87 1.52 2.17
6000 0.10 384.6 0.94 1.14 0.48 0.78 6000 0.21 195.1 1.03 1.36 0.59 0.96
100LC24/100Z24 100LC24/100Z24
2100 11.55 1.2 11.51 12.26 12.26 2100 0.51 27.4 3.07 3.07
3000 2.06 9.7 5.57 6.90 4.65 6.67 6.91 3000 0.55 36.4 3.06 3.07
3900 0.61 42.8 2.92 3.70 1.74 2.95 3.69 3900 0.91 28.5 2.63 3.07 2.62 3.07
4800 0.28 114.7 1.81 2.33 0.84 1.44 2.05 4800 1.21 26.4 2.00 3.04 1.22 2.03 2.77
6000 0.13 305.3 1.10 1.42 0.41 0.65 1.03 6000 0.26 155.6 1.19 1.67 1.73 0.51 0.81 1.27

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

92 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15
10.40

PURLIN & GIRT DESIGN MANUAL


Cantilevers
Limit State Capacity Tables

3000mm
Bridging (kN/m)
Span
k Inward Outward
(mm) L /150
0 1 2 0 1 2

75LC
No solutions available

75LC15
2100 0.05 264.2 0.51 0.54
3000 0.05 416.7 0.50 0.52 0.54
3900 0.05 541.7 0.49 0.51 0.54
100LC/100Z
100LC10/100Z10
2100 0.07 215.4 0.48 0.48
3000 0.06 339.0 0.47 0.48 0.48
3900 0.06 440.7 0.44 0.48 0.48
4800 0.07 477.6 0.44 0.48 0.48
6000 0.12 336.1 0.43 0.48 0.48
100LC12/100Z12
2100 0.08 168.7 0.59 0.62
3000 0.08 266.7 0.56 0.59 0.62
3900 0.08 346.7 0.54 0.59 0.62
4800 0.09 376.5 0.53 0.59 0.62
6000 0.15 266.7 0.52 0.59 0.47 0.60
100LC15/100Z15
2100 0.11 132.1 0.77 0.80
3000 0.10 208.3 0.75 0.77 0.80
3900 0.10 270.8 0.72 0.77 0.80
4800 0.11 293.6 0.70 0.77 0.80
6000 0.19 208.3 0.67 0.77 0.63 0.78
100LC19/100Z19
2100 0.13 105.3 1.00 1.07
3000 0.12 165.3 0.97 1.01 1.07
3900 0.12 214.9 0.93 1.00 1.07
4800 0.14 233.6 0.90 1.00 1.07
6000 0.24 164.6 0.83 1.00 0.53 0.82 1.02
100LC24/100Z24
2100 0.17 83.3 1.29 1.36
3000 0.15 131.6 1.26 1.30 1.36
3900 0.15 171.1 1.20 1.29 1.36
4800 0.17 186.0 1.16 1.29 1.36
6000 0.31 131.1 1.03 1.28 0.75 1.08 1.32

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

www.fielders.com.au 93
FINISH ON TOP WITH FIELDERS
10.40
PURLIN & GIRT DESIGN MANUAL

Cantilevers continued
Limit State Capacity Tables

1000mm 2000mm
Bridging (kN/m) Bridging (kN/m)
Span Span
k Inward Outward k Inward Outward
(mm) L /150 (mm) L /150
0 1 2 0 1 2 0 1 2 0 1 2

100FC 100FC
100FC10 100FC10
2100 4.99 2.8 4.49 4.49 2100 0.22 63.3 1.13 1.13
3000 0.89 22.5 2.57 1.92 2.53 3000 0.24 84.4 1.13 1.13
3900 0.26 99.2 1.36 0.68 1.23 1.36 3900 0.39 66.0 1.13 1.08 1.13
4800 0.12 264.5 0.86 0.58 0.85 4800 0.52 61.1 1.07 0.48 0.82 1.13
6000 0.06 714.3 0.53 0.42 6000 0.11 360.4 0.64 0.51
100FC12 100FC12
2100 6.03 2.3 5.46 5.46 2100 0.27 52.4 1.37 1.37
3000 1.07 18.6 3.12 2.24 3.07 3000 0.29 69.7 1.37 1.37
3900 0.32 82.0 1.65 0.88 1.47 1.65 3900 0.48 54.6 1.37 1.28 1.37
4800 0.15 219.2 1.04 0.41 0.69 1.02 4800 0.63 50.6 1.21 1.37 0.60 0.96 1.37
6000 0.07 588.2 0.64 0.51 6000 0.13 298.5 0.71 0.77 0.22 0.41 0.62
100FC15 100FC15
2100 7.59 1.8 7.06 7.06 2100 0.34 41.7 1.76 1.76
3000 1.35 14.8 3.67 3.97 3.13 3.97 3000 0.36 55.4 1.76 1.76
3900 0.40 65.3 1.94 2.13 1.18 1.86 2.13 3900 0.60 43.4 1.65 1.76 1.59 1.76
4800 0.18 173.9 1.21 1.34 0.54 0.98 1.25 4800 0.80 40.2 1.44 1.76 0.80 1.35 1.68
6000 0.09 465.1 0.74 0.83 0.44 0.68 6000 0.17 236.7 0.84 0.99 0.54 0.82
100FC19 100FC19
2100 9.84 1.4 9.72 9.91 2100 0.44 32.2 2.48 2.48
3000 1.75 11.4 4.87 5.57 4.28 5.57 3000 0.47 42.7 2.48 2.48
3900 0.52 50.3 2.55 2.99 1.58 2.60 2.98 3900 0.78 33.5 2.25 2.48 2.25 2.48
4800 0.24 134.5 1.58 1.89 0.74 1.33 1.78 4800 1.03 30.9 1.80 2.48 1.07 1.86 2.39
6000 0.11 360.4 0.96 1.17 0.60 0.94 6000 0.22 182.6 1.06 1.39 0.42 0.74 1.14
150LC/150Z 150LC/150Z
150LC12/150Z12 150LC12/150Z12
3000 3.19 6.3 5.69 5.70 3000 0.85 23.5 2.55 2.55
3900 0.94 27.6 3.09 2.41 3.08 3900 1.42 18.4 2.48 2.48
5100 0.35 96.9 1.69 0.92 1.61 1.70 5100 1.42 24.0 1.98 2.20 1.27 2.13 2.19
6000 0.20 197.0 1.18 1.21 0.50 0.92 1.20 6000 0.40 100.3 1.32 1.44 0.63 1.13 1.44
6900 0.13 356.6 0.87 0.90 0.57 0.87 6900 0.20 233.5 0.94 1.02 0.34 0.66 1.00
8100 0.08 701.3 0.62 0.65 0.52 8100 0.10 534.7 0.65 0.71 0.18 0.36 0.57
150LC15/150Z15 150LC15/150Z15
3000 4.07 4.9 7.13 7.32 7.33 3000 1.09 18.4 3.25 3.25
3900 1.21 21.7 3.68 3.93 2.98 3.93 3900 1.80 14.4 3.25 3.25
5100 0.45 76.1 1.96 2.17 1.16 1.97 2.17 5100 1.80 18.8 2.24 2.81 1.61 2.60 2.80
6000 0.26 154.4 1.36 1.54 0.62 1.15 1.53 6000 0.51 78.6 1.48 1.83 0.78 1.39 1.83
6900 0.16 280.5 1.00 1.15 0.73 1.06 6900 0.25 182.5 1.06 1.30 0.43 0.84 1.22
8100 0.10 545.5 0.70 0.82 0.40 0.64 8100 0.13 418.6 0.73 0.90 0.23 0.45 0.70
150LC19/150Z19 150LC19/150Z19
3000 5.15 3.9 8.84 10.07 9.42 10.07 3000 1.37 14.6 4.47 4.47
3900 1.52 17.2 4.54 5.40 4.06 5.37 3900 2.28 11.4 4.03 4.47 4.47
5100 0.57 60.2 2.39 2.99 1.49 2.58 2.98 5100 2.28 14.9 2.71 3.86 2.06 3.39 3.84
6000 0.33 122.7 1.65 2.10 0.81 1.56 2.01 6000 0.64 62.2 1.80 2.49 1.01 1.91 2.42
6900 0.21 222.2 1.20 1.54 0.48 0.95 1.38 6900 0.32 144.7 1.28 1.74 1.79 0.57 1.10 1.59
8100 0.12 435.5 0.85 1.09 1.127 0.52 0.87 8100 0.16 331.3 0.88 1.18 1.24 0.58 0.96
150LC24/150Z24 150LC24/150Z24
3000 6.58 3.0 11.21 13.68 12.82 13.68 3000 1.76 11.4 6.08 6.08
3900 1.94 13.4 5.54 7.34 5.24 7.34 3900 2.92 8.9 5.23 6.08 6.08
5100 0.72 47.0 2.85 4.06 1.94 3.44 4.05 5100 2.92 11.6 3.13 5.21 2.66 4.55 5.22
6000 0.42 95.7 1.94 2.80 2.86 1.07 2.02 2.75 6000 0.82 48.6 2.07 3.32 3.43 1.33 2.47 3.32
6900 0.27 173.6 1.41 2.05 2.14 0.65 1.23 1.86 6900 0.41 113.0 1.47 2.31 2.44 0.76 1.43 2.14
8100 0.16 339.6 0.98 1.42 1.53 0.68 1.13 8100 0.21 258.4 1.00 1.55 1.68 0.42 0.76 1.25

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

94 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15
10.40

PURLIN & GIRT DESIGN MANUAL


Cantilevers continued
Limit State Capacity Tables

3000mm
Bridging (kN/m)
Span
k Inward Outward
(mm) L /150
0 1 2 0 1 2

100FC
100FC10
2100 0.07 194.4 0.50 0.50
3000 0.07 303.0 0.50 0.50
3900 0.07 393.9 0.49 0.50 0.50
4800 0.08 426.7 0.48 0.50 0.50
6000 0.13 303.0 0.47 0.50 0.42 0.50
100FC12
2100 0.09 159.1 0.61 0.61
3000 0.08 250.0 0.61 0.61
3900 0.08 325.0 0.58 0.61 0.61
4800 0.09 355.6 0.57 0.61 0.61
6000 0.16 251.6 0.54 0.61 0.51 0.61
100FC15
2100 0.11 127.3 0.76 0.78
3000 0.10 200.0 0.74 0.76 0.78
3900 0.10 260.0 0.71 0.76 0.78
4800 0.11 283.2 0.70 0.76 0.78
6000 0.20 200.0 0.66 0.76 0.46 0.66 0.78
100FC19
2100 0.14 97.9 1.08 1.10
3000 0.13 153.8 1.06 1.08 1.10
3900 0.13 200.0 1.01 1.08 1.10
4800 0.15 217.7 0.97 1.08 1.10
6000 0.26 153.8 0.88 1.07 0.64 0.93 1.10
150LC/150Z
150LC12/150Z12
3000 0.24 84.4 1.14 1.14
3900 0.24 110.2 1.14 1.14
5100 0.29 117.2 1.14 1.14
6000 0.47 84.6 1.09 1.14 0.87 1.14
6900 0.67 68.2 0.93 1.14 0.48 0.84 1.14
8100 0.24 224.1 0.68 0.84 0.44 0.69
150LC15/150Z15
3000 0.30 66.2 1.45 1.45
3900 0.30 86.4 1.45 1.45
5100 0.37 91.9 1.41 1.45 1.45
6000 0.60 66.3 1.28 1.45 1.08 1.45
6900 0.86 53.6 1.05 1.45 0.60 1.05 1.45
8100 0.31 175.3 0.76 1.07 0.55 0.85
150LC19/150Z19
3000 0.38 52.5 1.99 1.99
3900 0.38 68.2 1.94 1.99 1.99
5100 0.47 72.6 1.78 1.99 1.99
6000 0.76 52.5 1.58 1.99 1.48 1.92 1.99
6900 1.09 42.4 1.30 1.95 1.99 0.78 1.43 1.86
8100 0.39 139.2 0.92 1.39 1.47 0.71 1.16
150LC24/150Z24
3000 0.49 41.0 2.70 2.70
3900 0.49 53.3 2.65 2.70 2.70
5100 0.60 56.8 2.33 2.70 2.70
6000 0.98 41.0 1.93 2.70 1.93 2.64 2.70
6900 1.39 33.1 1.50 2.60 2.70 1.04 1.87 2.55
8100 0.50 108.4 1.04 1.81 1.99 0.52 0.93 1.51

General Notes:
O Inward = Inward load capacity for bridging O L/150 = Load for deflection for span/150 kN/m
configuration kN/m O k = Deflection factor, see notes to capacity tables
O Outward = Outward load capacity for bridging section 7.3
configuration kN/m O QQ Values below this line exceed standard delivery

O Numbers in bold italics require grade 8.8 bolts length of 12m

www.fielders.com.au 95
FINISH ON TOP WITH FIELDERS
10.40
PURLIN & GIRT DESIGN MANUAL

Cantilevers continued
Limit State Capacity Tables

1000mm 2000mm
Bridging (kN/m) Bridging (kN/m)
Span Span
k Inward Outward k Inward Outward
(mm) L /150 (mm) L /150
0 1 2 0 1 2 0 1 2 0 1 2

200LC/200Z 200LC/200Z
200LC15/200Z15 200LC15/200Z15
3000 8.56 2.3 8.49 8.49 3000 2.28 8.8 4.25 4.25
3900 2.52 10.3 5.30 5.24 5.37 3900 3.80 6.9 4.04 4.04
5100 0.94 36.1 2.82 2.97 2.09 2.97 5100 3.80 9.0 3.21 3.73 2.88 3.73
6000 0.54 73.5 1.94 2.10 1.15 2.03 2.10 6000 1.07 37.4 2.10 2.50 1.43 2.44 2.51
6900 0.35 133.3 1.41 1.57 0.73 1.29 1.56 6900 0.53 87.0 1.49 1.78 0.85 1.50 1.78
8100 0.21 260.9 0.98 1.13 0.40 0.74 1.10 8100 0.27 198.5 1.02 1.23 0.45 0.82 1.22
200LC19/200Z19 200LC19/200Z19
3300 6.94 3.2 10.95 11.82 11.94 3000 3.04 6.6 6.64 6.64
3900 3.36 7.7 7.04 8.01 7.46 8.01 3900 5.06 5.1 6.45 6.64 6.64
5100 1.25 27.1 3.46 4.43 2.98 4.43 5100 5.06 6.7 3.99 5.72 4.05 5.72
6000 0.73 55.2 2.35 3.14 1.70 2.89 3.12 6000 1.43 28.1 2.59 3.73 2.11 3.49 3.74
6900 0.46 100.0 1.70 2.34 1.01 1.79 2.33 6900 0.71 65.2 1.82 2.66 1.18 2.07 2.66
8100 0.28 195.7 1.18 1.68 0.55 1.08 1.59 8100 0.36 149.2 1.24 1.84 0.61 1.19 1.75
200LC24/200Z24 200LC24/200Z24
3300 8.76 2.5 14.03 16.55 16.25 3000 3.84 5.2 9.29 9.29
3900 4.25 6.1 8.90 11.21 9.94 11.21 3900 6.39 4.1 8.23 9.29 9.29
5100 1.58 21.5 4.37 6.21 4.01 6.00 6.18 5100 6.39 5.3 4.86 8.01 5.47 7.86
6000 0.92 43.7 2.91 4.34 2.21 3.86 4.37 6000 1.80 22.2 3.13 5.13 5.24 2.74 4.65 5.24
6900 0.58 79.2 2.08 3.14 3.26 1.31 2.51 3.21 6900 0.89 51.6 2.18 3.55 3.72 1.53 2.91 3.68
8100 0.35 154.7 1.43 2.18 2.34 0.72 1.44 2.11 8100 0.46 117.9 1.47 2.37 2.57 0.81 1.60 2.33
250LC/250Z 250LC/250Z
250LC19/250Z19 250LC19/250Z19
3600 7.63 3.1 11.15 11.76 11.84 3600 6.39 3.8 7.18 7.18
5100 2.04 16.6 4.38 5.42 3.73 5.42 5100 8.25 4.1 4.99 6.40 5.12 6.40
6000 1.18 33.9 2.96 3.83 1.99 3.64 3.82 6000 2.32 17.2 3.23 4.56 2.48 4.43 4.57
6900 0.75 61.4 2.14 2.86 1.16 2.30 2.85 6900 1.15 40.0 2.27 3.25 1.37 2.65 3.25
8100 0.45 120.0 1.48 2.05 0.63 1.31 2.01 8100 0.59 91.5 1.55 2.25 0.71 1.46 2.22
250LC24/250Z24 250LC24/250Z24
5100 2.62 13.0 5.42 7.84 4.64 7.84 5400 6.09 5.9 4.98 8.67 4.92 8.55
6000 1.52 26.4 3.59 5.55 2.49 4.84 5.52 6000 2.98 13.4 3.77 6.60 3.10 5.92 6.62
6900 0.96 47.9 2.55 4.14 1.46 2.98 4.12 6900 1.48 31.2 2.64 4.70 1.72 3.46 4.70
8100 0.58 93.6 1.74 2.91 0.80 1.64 2.71 8100 0.76 71.2 1.78 3.16 3.25 0.90 1.82 3.00
300LC 300LC
300LC24 300LC24
3600 17.35 1.4 20.94 20.94 3600 14.52 1.7 13.15 13.15
5100 4.65 7.3 8.29 10.96 10.22 10.96 5100 18.76 1.8 9.56 11.52 11.52
6000 2.69 14.9 5.44 7.75 5.82 7.75 6000 5.29 7.6 5.92 9.23 7.14 9.23
6900 1.70 27.0 3.84 5.79 3.70 5.79 6900 2.61 17.6 4.02 6.57 4.31 6.57
8100 1.02 52.8 2.56 4.16 2.06 3.72 4.13 8100 1.34 40.2 2.63 4.54 2.29 4.11 4.54
300LC30 300LC30
3600 22.29 1.1 30.50 34.00 34.22 3600 18.66 1.3 21.08 21.08
5100 5.97 5.7 10.89 15.66 14.14 15.66 5100 24.11 1.4 11.66 19.23 18.97
6000 3.45 11.6 6.77 11.08 8.33 11.08 6000 6.79 5.9 7.05 13.19 10.25 13.19
6900 2.19 21.0 4.57 8.27 4.95 8.06 8.23 6900 3.36 13.7 4.69 9.34 5.75 9.20 9.40
8100 1.32 41.1 2.96 5.64 5.91 2.71 5.26 5.91 8100 1.73 31.3 3.00 6.13 6.48 3.01 5.78 6.48
350LC 350LC
350LC30 350LC30
3600 36.43 0.7 34.85 34.85 3600 30.50 0.8 22.36 22.36
5100 9.75 3.5 16.06 19.19 19.14 5100 39.39 0.9 17.87 19.48 19.48
6000 5.64 7.1 9.93 13.58 13.45 6000 11.10 3.6 10.50 16.16 16.41
6900 3.58 12.9 6.55 10.14 8.78 10.14 6900 5.49 8.4 6.97 11.51 10.16 11.51
8100 2.15 25.1 4.29 7.28 5.09 7.28 8100 2.82 19.1 4.43 7.96 5.64 7.96
400LC 400LC
400LC30 400LC30
3600 44.87 0.5 30.77 30.77 3600 37.57 0.6 21.57 21.57
5100 12.02 2.8 15.58 21.96 21.91 5100 48.53 0.7 16.58 18.29 18.29
6000 6.95 5.8 9.58 15.54 12.48 15.54 6000 13.67 2.9 9.93 16.55 15.34 16.55
6900 4.41 10.4 6.40 11.60 7.38 11.60 6900 6.76 6.8 6.54 13.17 8.57 13.17
8100 2.65 20.4 4.10 8.33 4.02 8.17 8100 3.47 15.5 4.15 9.11 4.46 8.99

96 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15
10.40

PURLIN & GIRT DESIGN MANUAL


Cantilevers continued
Limit State Capacity Tables

3000mm
Bridging (kN/m)
Span
k Inward Outward
(mm) L /150
0 1 2 0 1 2

200LC/200Z
200LC15/200Z15
3000 0.63 31.5 1.98 1.98
3900 0.63 41.0 1.98 1.98
5100 0.78 43.6 1.98 1.98
6000 1.27 31.5 1.86 1.98 1.89 1.98
6900 1.81 25.4 1.52 1.98 1.09 1.88 1.98
8100 0.65 83.5 1.08 1.46 0.56 1.00 1.45
200LC19/200Z19
3000 0.85 23.7 2.95 2.95
3900 0.85 30.8 2.95 2.95
5100 1.04 32.8 2.86 2.95 2.95
6000 1.69 23.7 2.31 2.95 2.66 2.95
6900 2.41 19.1 1.91 2.95 1.60 2.67 2.95
8100 0.86 62.6 1.34 2.18 0.77 1.44 2.10
200LC24/200Z24
3000 1.07 18.7 4.13 4.13
3900 1.07 24.4 4.13 4.13
4800 1.21 26.5 3.82 4.13 4.13
6000 2.14 18.7 2.96 4.13 3.57 4.13
6900 3.04 15.1 2.25 4.01 4.13 2.08 3.58 4.13
8100 1.09 49.6 1.53 2.78 3.04 1.01 1.95 2.78
250LC/250Z
250LC19/250Z19
3600 1.36 17.6 3.60 3.60
5100 1.69 20.1 3.60 3.60
6000 2.76 14.5 2.92 3.60 3.34 3.60
6900 3.93 11.7 2.37 3.54 1.88 3.34 3.54
8100 1.41 38.4 1.66 2.66 0.88 1.79 2.66
250LC24/250Z24
5100 2.17 15.7 4.78 5.22 5.22
6000 3.54 11.3 3.65 5.22 4.41 5.22
6900 5.04 9.1 2.70 5.22 2.35 4.43 5.22
8100 1.80 30.0 1.84 3.70 3.85 1.12 2.23 3.60
300LC
300LC24
3600 3.10 7.8 7.29 7.29
5100 3.85 8.8 7.05 7.05
6000 6.27 6.4 5.47 6.84 6.84
6900 8.93 5.2 4.21 6.60 5.40 6.60
8100 3.20 16.9 2.74 5.38 2.83 4.99 5.37
300LC30
3600 3.98 6.0 10.42 10.42
5100 4.94 6.9 9.62 10.42 10.42
6000 8.05 5.0 7.11 10.35 10.35
6900 11.47 4.0 4.91 10.13 7.62 10.13
8100 4.11 13.2 3.14 7.20 7.68 3.71 6.93 7.68
350LC
350LC30
3600 6.50 3.7 12.62 12.62
5100 8.08 4.2 12.14 12.14
6000 13.16 12.7 10.15 11.74 11.74 General Notes:
6900 18.75 5.3 7.42 11.31 11.31 O Inward = Inward load capacity for bridging
8100 6.71 8.0 4.71 9.43 6.91 9.43
400LC configuration kN/m
400LC30 O Outward = Outward load capacity for bridging

3600 8.01 3.0 13.12 13.13


5100 9.95 3.4 12.43 12.43 configuration kN/m
6000 16.21 6.4 10.03 11.88 11.88 O Numbers in bold italics require grade 8.8 bolts

6900 23.09 14.9 6.83 11.30 11.30 O L/150 = Load for deflection for span/150 kN/m
8100 8.26 6.5 4.32 10.53 5.50 10.53
O k = Deflection factor, see notes to capacity tables

section 7.3
O QQ Values below this line exceed standard delivery

length of 12m

www.fielders.com.au 97
FINISH ON TOP WITH FIELDERS
PURLIN & GIRT DESIGN MANUAL

Notes

98 www.fielders.com.au
FINISH ON TOP WITH FIELDERS
1.15

PURLIN & GIRT DESIGN MANUAL


Notes

www.fielders.com.au 99
FINISH ON TOP WITH FIELDERS
PURLIN & GIRT DESIGN MANUAL

Notes

100 www.fielders.com.au
FINISH ON TOP WITH FIELDERS

You might also like