SERVICE MANUAL
004356MIU
CPIA NO CONTROLADA
CPIA NO CONTROLADA
No.
Symptom Possible Cause
Definition
CPIA NO CONTROLADA
CPIA NO CONTROLADA
No.
Symptom Possible Cause
Definition
Service Call
Conditions
Appendix:
position sensor connector
back to the home position.
Defective scanner drive motor
connector
Defective BICU board
CPIA NO CONTROLADA
CPIA NO CONTROLADA
No.
Symptom Possible Cause
Definition
CPIA NO CONTROLADA
CPIA NO CONTROLADA
No.
Symptom Possible Cause
Definition
Service Call
Conditions
Appendix:
Polygonal mirror motor error
CPIA NO CONTROLADA
CPIA NO CONTROLADA
No.
Symptom Possible Cause
Definition
TD sensor error
Defective ID sensor
Insufficient developer
Defective drum operation
392 B The ID sensor does not detect a
Defective development roller
correct pattern during developer
operation
initialization ( 2-214-001).
Loose connection of the PCU
Insufficient voltage for the
charge roller
CPIA NO CONTROLADA
CPIA NO CONTROLADA
No.
Symptom Possible Cause
Definition
Service Call
Conditions
Appendix:
transfer unit or the separation
unit
Defective transfer roller
Defective thermistor
541 A The fusing temperature remains Incorrect installation of the
lower than the specified thermistor
temperature by 20 degrees Celsius. Defective power supply unit
Loose connectors
CPIA NO CONTROLADA
CPIA NO CONTROLADA
No.
Symptom Possible Cause
Definition
Defective thermistor
545 A After the fusing temperature
Incorrect installation of the
reaches the target, the fusing lamp
thermistor
remains on for 12 seconds.
Defective power supply unit
CPIA NO CONTROLADA
CPIA NO CONTROLADA
No.
Symptom Possible Cause
Definition
Service Call
Conditions
Appendix:
detected within one second after
operation begins.
760 B The ADF sends the FGATE signal Defective ADF board
before it is requested to scan Defective input/output board
originals. Loose connection
CPIA NO CONTROLADA
CPIA NO CONTROLADA
No.
Symptom Possible Cause
Definition
CPIA NO CONTROLADA
CPIA NO CONTROLADA
No.
Symptom Possible Cause
Definition
Controller-engine inconsistency
Service Call
Conditions
Appendix:
copier/facsimile model
The controller of the
980 B
The controller is incompatible with printer/scanner/copier model
the engine. The controller of the optional
printer/scanner is installed to one of
the following models:
The MFP model
The copier/facsimile model
The printer/scanner/copier
model
NVRAM error
Defective NVRAM
Loose connection between the
981 B
An error occurs during engine BICU and the NVRAM
NVRAM check. Incorrect installation of the
NVRAM
Defective BICU
Localization error
CPIA NO CONTROLADA
CPIA NO CONTROLADA
No.
Symptom Possible Cause
Definition
Defective controller
984 B
Defective BICU
Print images are not transferred.
Loose connection between the
controller and the BICU
CPIA NO CONTROLADA
CPIA NO CONTROLADA
SC6xx
No.
Symptom Possible Cause/Countermeasure
Definition
Service Call
Conditions
Appendix:
632 C
No normal end signal returns. Defective or broken line
This symptom happens three between machine and device
times.
CPIA NO CONTROLADA
CPIA NO CONTROLADA
No.
Symptom Possible Cause/Countermeasure
Definition
There is no expanded
authentication module in the
machine. 1. Install the correct SD card or the
-001 B
The SD card or the file of the file of the expanded
expanded authentication module is authentication module.
broken. 2. Install the DESS module.
There is no DESS module in the
machine.
Version error
-002 B The version of the expanded 1. Install the correct file of the
authentication module is not expanded authentication
correct. module.
Authentication error
-001 C The authentication for the 1. Check and set the correct user
Embedded RCG-M fails at a dial up name (SP5816-156) and
connection. password (SP5816-157).
CPIA NO CONTROLADA
CPIA NO CONTROLADA
No.
Symptom Possible Cause/Countermeasure
Definition
Service Call
Conditions
Appendix:
Incorrect dial up connection
651
An unexpected error occurs when the modem (RCG-M) tries to call the center
with a dial up connection.
CPIA NO CONTROLADA
CPIA NO CONTROLADA
No.
Symptom Possible Cause/Countermeasure
Definition
Controller stalled
Controller board installed
incorrectly
Defective controller board
After powering on the machine, Operation panel connector loose
672 B communication between the or defective
controller and operation panel does Poor connection of DIMM and
not begin, or the communication is optional boards on the controller
interrupted after a normal startup. board
1. Check the setting of
SP5875-001. If the setting is set
to "1 (OFF)", change it to "0
(ON)".
CPIA NO CONTROLADA
CPIA NO CONTROLADA
SC8xx
No.
Symptom Possible Cause/Countermeasure
Definition
Monitor Error
Service Call
Conditions
Appendix:
error when the boot loader
attempts to read the OS Flash ROM data defective;
817
self-diagnostic module, system change the controller firmware
B
kernel, or root system files SD card data defective; use
from the OS Flash ROM, or the another SD card
items on the SD card in the
controller slot are false or
corrupted.
Kernel stop
CPIA NO CONTROLADA
CPIA NO CONTROLADA
CPIA NO CONTROLADA
CPIA NO CONTROLADA
Service Call
Conditions
Appendix:
prescribed value. used for initializing CPU.
1. Replace the controller board.
CPIA NO CONTROLADA
CPIA NO CONTROLADA
ASIC error
[0B00] B
The write-&-verify check error Defective controller board
has occurred in the ASIC. 1. Replace the controller.
CPIA NO CONTROLADA
CPIA NO CONTROLADA
Service Call
Conditions
Appendix:
1. Check that the HDD is
PHY IC error
CPIA NO CONTROLADA
CPIA NO CONTROLADA
Loose connection
Defective standard NVRAM
824 The controller cannot
B Defective controller
[1401] recognize the standard
1. Check the standard NVRAM is
NVRAM installed or detects
firmly inserted into the socket.
that the NVRAM is defective.
2. Replace the NVRAM.
3. Replace the controller
An RTC device is
recognized, and the
B
difference between the
RTC defective
RTC device and the CPU
1. Replace the RTC device.
exceeds the defined limit.
826 No RTC device is
recognized.
CPIA NO CONTROLADA
CPIA NO CONTROLADA
Verification error
Loose connection
Error is detected during a Defective SDRAM DIMM
[0201] B
write/verify check for the Defective controller
standard RAM (SDRAM 1. Replace the SDRAM
DIMM). DIMM.
Service Call
Conditions
Appendix:
2. Replace the controller.
CPIA NO CONTROLADA
CPIA NO CONTROLADA
CPIA NO CONTROLADA
CPIA NO CONTROLADA
Service Call
Conditions
Appendix:
The machine starts up. The
IEEE802 11b card connection
853 C Loose connection between the
board is recognized. The
wireless card and the
wireless LAN card or
connection board
bluetooth card is not
recognized.
CPIA NO CONTROLADA
CPIA NO CONTROLADA
Defective controller
857 C 1. Check the USB connections,
USB interface error is
and make sure that they are
detected.
securely connected.
2. Replace the controller board.
Other error:
[31] A serious error occurs while Same as SC991
the data is encrypted.
CPIA NO CONTROLADA
CPIA NO CONTROLADA
No HDD installed
Unformatted HDD
HDD check error: The encryption key on the
[8] The HDD is not correctly controller is different from the
Service Call
Conditions
Appendix:
installed. one on the HDD
1. Install the HDD correctly.
2. Initialize the HDD.
Defective HDD
862 The number of bad sectors in
1. Format the HDD with
B the HDD (image data area)
SP5-832-002.
goes over 101.
2. Replace the HDD.
CPIA NO CONTROLADA
CPIA NO CONTROLADA
Defective HDD
863
The data stored in the HDD Defective controller
C
cannot be read correctly. 1. Replace the HDD.
2. Replace the controller.
SD card error
An application SD card is
867 B
removed from the boot slot An application SD card is
while an application is ejected.
activated.
CPIA NO CONTROLADA
CPIA NO CONTROLADA
Service Call
Conditions
Appendix:
the SD card reader.
switch off and on.
3. Remove and re-install the SD
card.
4. Replace the SD card.
5. Replace the controller.
CPIA NO CONTROLADA
CPIA NO CONTROLADA
876 An error was detected in the handling of the log data at power on or during
machine operation. This can be caused by switching the machine off while
it is operating.
CPIA NO CONTROLADA
CPIA NO CONTROLADA
Service Call
Conditions
Appendix:
-099 C Log Data Error 99
1. Ask your supervisor.
CPIA NO CONTROLADA
CPIA NO CONTROLADA
SC9xx
Printer error
CPIA NO CONTROLADA
CPIA NO CONTROLADA
Service Call
Conditions
Appendix:
990 B Software defective
NVRAM. This
Internal parameter incorrect
information can be
Insufficient working memory
checked by using
SP7-403. See the data
and the situation in
which this SC occurs.
Then report the data and
conditions to your
technical control center.
Undefined error
CPIA NO CONTROLADA
CPIA NO CONTROLADA
CPIA NO CONTROLADA
CPIA NO CONTROLADA
3.2.1 SUMMARY
There are four levels of service call conditions.
Service Call
Conditions
Appendix:
A does not operate until the service turn the main power switch off
representative resets the SC code. and on.
The machine operates as usual excluding the Turn the main power switch off
C
unit related to the service call. and on.
If a problem involves circuit boards, see if you can solve the problem by
disconnecting and reconnecting all connectors before deciding to replace a circuit
board.
If a problem involves a motor lock, check the mechanical load before deciding to
replace a motor or sensor.
If working on a fax-equipped machine, switching power off and on may cause loss
of data stored in the memory.
CPIA NO CONTROLADA
CPIA NO CONTROLADA
No.
Symptom Possible Cause
Definition
CPIA NO CONTROLADA
CPIA NO CONTROLADA
No.
Symptom Possible Cause
Definition
Service Call
Conditions
Appendix:
position sensor connector
back to the home position.
Defective scanner drive motor
connector
Defective BICU board
CPIA NO CONTROLADA
CPIA NO CONTROLADA
No.
Symptom Possible Cause
Definition
CPIA NO CONTROLADA
CPIA NO CONTROLADA
No.
Symptom Possible Cause
Definition
Service Call
Conditions
Appendix:
Polygonal mirror motor error
CPIA NO CONTROLADA
CPIA NO CONTROLADA
No.
Symptom Possible Cause
Definition
TD sensor error
Defective ID sensor
Insufficient developer
Defective drum operation
392 B The ID sensor does not detect a
Defective development roller
correct pattern during developer
operation
initialization ( 2-214-001).
Loose connection of the PCU
Insufficient voltage for the
charge roller
CPIA NO CONTROLADA
CPIA NO CONTROLADA
No.
Symptom Possible Cause
Definition
Service Call
Conditions
Appendix:
transfer unit or the separation
unit
Defective transfer roller
Defective thermistor
541 A The fusing temperature remains Incorrect installation of the
lower than the specified temperature thermistor
by 20 degrees Celsius. Defective power supply unit
Loose connectors
CPIA NO CONTROLADA
CPIA NO CONTROLADA
No.
Symptom Possible Cause
Definition
Defective thermistor
545 A After the fusing temperature reaches
Incorrect installation of the
the target, the fusing lamp remains
thermistor
on for 12 seconds.
Defective power supply unit
CPIA NO CONTROLADA
CPIA NO CONTROLADA
No.
Symptom Possible Cause
Definition
Service Call
Conditions
Appendix:
within one second after operation
begins.
Accounting error 1
CPIA NO CONTROLADA
CPIA NO CONTROLADA
No.
Symptom Possible Cause
Definition
760 B The ADF sends the FGATE signal Defective ADF board
before it is requested to scan Defective input/output board
originals. Loose connection
CPIA NO CONTROLADA
CPIA NO CONTROLADA
No.
Symptom Possible Cause
Definition
Service Call
Conditions
Appendix:
The ADF continues to send the
762 B
FGATE signal for more than 60 Defective ADF connector
seconds after the ADF starts Defective SBU board
scanning.
Memory error
CPIA NO CONTROLADA
CPIA NO CONTROLADA
No.
Symptom Possible Cause
Definition
NVRAM error
Defective NVRAM
Loose connection between the
981 B
An error occurs during engine BICU and the NVRAM
NVRAM check. Incorrect installation of the
NVRAM
Defective BICU
Localization error