You are on page 1of 120

SFS | Steel Framing System

Technical Manual
Version 5.2 | December 2014
Preamble British Board of Agrment (BBA) Certificate
This document has been compiled to give Kingspan Product summary and guidance on
Steel Building Solutions customers guidance on the specification, installation, maintenance and
correct application of design and engineering durability
principles of the Kingframe Steel Framing System.
Kingframe SFS Design Guide
This document should be read alongside our other Detailed and Basic Design Services - an
publications which can be found at: overview of the services offered by Kingspan
www.kingspanpanels.co.uk/sbs Steel Building Solutions

SFS Designers Risk Assessment In addition to the guidance contained in these


Identified risks associated with general documents, we offer an installer training course.
installation of Infill and Oversail SFS The course gives the attendee a better
(for project specific guidance, please consult the Kingspan understanding of SFS, its applications, benefits and
design service) installation principles - helping to increase
Product Brochure productivity, reduce costs and minimise SFS related
Product overview and system applications health and safety issues. Kingspan also offer a site
Installation Manual inspection and report service.
Guide to installation procedures for both Infill
and Oversail SFS framing Further information can be found on the Kingspan
Steel Building Solutions web site at:
www.kingspanpanels.co.uk/sbs

Contents
1 SYSTEM OVERVIEW ........................................................................................................................... 1
1.1 Overview .................................................................................................................................. 1
1.2 Design Considerations ............................................................................................................. 1
1.3 Design Guidance...................................................................................................................... 2
1.4 Construction Design Management........................................................................................... 2
2 SFS STANDARD COMPONENTS ....................................................................................................... 3
2.1 Basic Components ................................................................................................................... 3
2.2 Kingspan Section Range ......................................................................................................... 4
2.3 Secondary Products ................................................................................................................. 4
2.4 C Section Range .................................................................................................................... 5
2.4.1 To BS 5950-5:1998 ..................................................................................................... 5
2.4.2 To BS EN 1993-1-3:2006 ............................................................................................ 6
2.5 U Section Range .................................................................................................................... 7
2.5.1 To BS 5950-5:1998 ..................................................................................................... 7
2.5.2 To BS EN 1993-1-3:2006 ............................................................................................ 8
2.6 Ancillary Products .................................................................................................................... 9
2.7 Span Tables ............................................................................................................................. 9
3 SFS STANDARD FIXINGS ................................................................................................................ 16
3.1 Recommended Fixings .......................................................................................................... 16
4 INFILL SFS ......................................................................................................................................... 20
4.1 Design Principles ................................................................................................................... 20
4.1.1 General Stud Design & Construction ........................................................................ 20
4.1.2 Structural Openings ................................................................................................... 20
4.1.3 Splicing of Sections ................................................................................................... 20
4.1.4 Deflection Head Details ............................................................................................. 20
4.1.5 Mid Span Restraint (Detail B.01) ............................................................................... 21
4.1.6 Cladding Treatments & Boarding .............................................................................. 21
rd
4.1.7 2/3 Minimum Bearing............................................................................................... 21
4.1.8 Service Holes............................................................................................................. 22
4.1.9 Curved Walling .......................................................................................................... 22
4.1.10 Braced Bays .............................................................................................................. 23
4.1.11 Parapets and Downstands ........................................................................................ 23
4.1.12 Ribbon Windows ........................................................................................................ 23
4.1.13 Brise Soleil ................................................................................................................. 23
4.1.14 Kingposts ................................................................................................................... 24
4.1.15 Oversail Cleats .......................................................................................................... 24
5 OVERSAIL SFS .................................................................................................................................. 25

i
5.1 Design Principles ................................................................................................................... 25
5.1.1 General Stud Design & Construction ........................................................................ 25
5.1.2 Deflection Conditions ................................................................................................. 25
5.1.3 Splicing of Sections ................................................................................................... 26
5.1.4 Structural Openings ................................................................................................... 26
5.1.5 Mid Span Restraint (Detail B.01) ............................................................................... 26
5.1.6 Cladding Treatments & Boarding (Detail E.01 & E.02) ............................................. 26
5.1.7 Service Holes............................................................................................................. 26
5.1.8 Curved Walling .......................................................................................................... 26
5.1.9 Braced Bays .............................................................................................................. 26
5.1.10 Parapets and Downstands ........................................................................................ 26
5.1.11 Ribbon Windows ........................................................................................................ 26
5.1.12 Brise Soleil ................................................................................................................. 26
5.1.13 Fixings ....................................................................................................................... 26
6 STANDARD DETAILS........................................................................................................................ 27
6.1 A Series Basic Connections .............................................................................................. 27
6.2 B Series Construction Details............................................................................................ 53
6.3 C Series Opening Construction ......................................................................................... 64
6.4 D Series Oversail Details .................................................................................................. 87
6.5 E Series Boarding Details ............................................................................................... 101
6.6 F Series Finishes Details................................................................................................. 104
6.7 G Series Building Details................................................................................................. 106
7 CLADDING TREATMENTS ............................................................................................................. 115
7.1 Introduction .......................................................................................................................... 115
7.2 Masonry ............................................................................................................................... 115
7.3 Insulated Render .................................................................................................................. 115
7.4 Terracotta Rainscreen ......................................................................................................... 116
7.5 Timber Rainscreen ............................................................................................................... 116
7.6 Metal Rainscreen ................................................................................................................. 116
7.7 Stone Panels ........................................................................................................................ 116
8 COSHH & TECHNICAL DATASHEETS .......................................................................................... 117
8.1 General Specification Notes ................................................................................................ 117
8.2 COSHH Datasheet ............................................................................................................... 118
9 SUPPORT SERVICES...................................................................................................................... 120
9.1 Material Ordering & Production Enquiries ........................................................................... 120
9.2 Technical Enquiries .............................................................................................................. 120
9.3 Sales & Commercial Enquiries ............................................................................................ 120
9.4 Site Support Enquiries ......................................................................................................... 120

ii
External References
Publications
BS 5950 Structural Use of Steelwork in Building - Part 5; Code of Practice for Design of Cold Formed Thin
Gauge Sections
BS 6399 Series; Actions Buildings
BS EN 1990 Series; Basis for structural design
BS EN 1991 Series; Actions on structures
BS EN 1993 Series; Design of steel structures
National Structural Steelwork Specification (NSSS) Fifth Edition, The British Constructional Steelwork
Association (BCSA)
SCI Guide P125; Building design using cold formed steel sections: Worked examples to BS 5950: Part 5:
1987
SCI Guide P301; Building design using cold formed steel sections: Light steel framing in residential
construction
SCI Guide P262; Building design using cold formed steel sections: Durability of Light Steel Framing in
Residential Building
BS 7364:1990 Specification for galvanized steel studs and channels for stud and sheet partitions and linings
using screw fixed gypsum wallboards
BS 8000 Series; Workmanship on building site; Codes of practice
BS EN 10346; Continuously hot-dip coated steel flat products. Technical delivery conditions.
Building Regulations; Approved Documents

Industry/Regulatory Bodies

Steel Construction Institute (SCI) Building Research Establishment (BRE)


http://www.steel-sci.org/ http://www.bre.co.uk/

Federation of Plastering & Drywall Contractors British Board of Argrment (BBA)


(FPDC) www.bbacerts.co.uk
http://www.fpdc.org/
The National House Building Council (NHBC)
British Construction Steelwork Association (BCSA) http://www.nhbc.co.uk/
http://www.steelconstruction.org/
Communities & Local Government Building
Regulations
http://www.communities.gov.uk/planningandbuilding/
Unauthorised Distribution And Liability
Copyright
All text and drawing information contained within this document remains the sole property of Kingspan Steel
Building Solutions. Copying and unauthorised distribution of this document is strictly prohibited. This document
must be read as a whole and must not have any of its content added to, removed nor modified.

Liabilities
This document does not serve as a specification without prior written consultation with a Kingspan Steel
Building Solutions engineer. Details and information provided do not constitute an extension of any warranty or
acceptance of liability by Kingspan Steel Building Solutions unless used under the specific terms of the
Kingspan Steel Building Solutions Detailed Design Service. Kingspan Steel Building Solutions will not be held
liable for any consequential losses incurred by any party through the use of this document. Customers of
Kingspan Steel Building Solutions accept that the information provided in this document is supplied for general
guidance purposes only.

Unauthorised Distribution
This document is provided in good faith to Kingspan customers to assist in the design of the SFS product. It
should not be distributed to third parties without the prior written consent of Kingspan Steel Building Solutions.

iii
for low rise buildings. This is beyond the scope of
1 SYSTEM OVERVIEW this manual but information is available on request
from Kingspan.
1.1 Overview
1.2 Design Considerations
The Kingframe Steel Framing System (SFS) is a
component supply structural stud faade system Design considerations affect the performance of the
commonly used in two main methods: Infill and SFS systems. Some of these are described below;
Oversail. The system consists of C shaped studs
and U shaped tracks designed on a project specific Design Life
basis to form the inner leaf of an external faade. SFS sections are hot dip galvanised with a 20m
zinc coating and are intended for warm frame
Both systems are constructed on-site and must be construction. This is to say that the SFS is always
designed and installed to relevant codes and fully enclosed within the warm envelope of the
standards. Liability for the quality and accuracy of facade by insulation applied to the external face of
the installation rests with the installation contractor the SFS.
and not Kingspan Steel Building Solutions.
Where parapets, upstands, downstands, etc. are
SFS has been extensively used in construction formed in SFS, they should be insulated to all
projects covering residential flats, apartments, exposed faces in order to satisfy this requirement.
healthcare and educational developments,
commercial developments, public buildings and Assuming that the SFS is maintained within a warm
1
industrial properties. frame environment, current industry guidance is
that a design life of 250 years can be expected.
Sections are supplied to site as individual Where the SFS is installed in a cold frame
components and fully assembled in-situ. This is an environment (low risk of water ingress, some risk of
advantage where site access/craneage is restricted. condensation), this reduces to 50-60 years.
Components can be supplied in final required
lengths or standard lengths cut to suit on site. By SFS may be used in potentially corrosive
cutting to length on site, construction tolerances in environments, such as swimming pool buildings,
structures can be fully accommodated. providing that the internal finishes are designed to
protect the frame. There are a number of boards
Infill Systems are typically supported at the specifically designed for swimming pools, such as
2
slab edge between hot-rolled steel or concrete. Promat Masterboard which is a moisture resistant
This allows insulation and external finishes to lining system for swimming pool applications.
be installed outside the main structural frame if
the correct tolerance scheme is adopted. The Live Load Deflection
system is suitable for both low and high-rise Every structure, whether concrete or steel, will
construction. A deflection allowance is required move when placed under load during normal use.
at each floor level. This is anticipated within the design of the building
Oversail Systems are fitted outside the line of by the engineers and must be accommodated
the structural frame using support cleats at within the SFS system. This movement is in the
each floor level with connections designed to vertical plane and is normally at its maximum
allow slab deflection. It is particularly suited to displacement at mid-span between vertical supports
situations where cladding materials are e.g. columns. The expected total movement can be
3
sensitive to differing movement of the main calculated by using the formula below ;
frame. Adequate base support must be Maximum deflection = Span between supporting
provided to accommodate vertical loading. columns 360

Both systems achieve early weather protection of The Kingspan Steel Building Solutions standard
the building allowing other internal fitting trades to SFS System can achieve a maximum deflection
work inside the structure and removing external tolerance at the head of an infill frame of 25mm.
cladding from the critical path. Furthermore, these Conditions that have a greater live load deflection
systems also provide lateral support to most value must be referred to Kingspan Steel Building
cladding materials including masonry, profiled metal
sheets, proprietary panels, insulated render 1
P262 Durability of Light Steel Framing in Residential Building.
systems, terracotta and timber rain screen systems. Second Edition. The Steel Construction Institute, 2009
2
It should be noted that SFS is not intended to This is provided as an example of available boarding only and
does not form a specification or recommendation from Kingspan.
provide vertical support for masonry facades. Frame linings are beyond the scope of Kingspans design and
supply.
3
It is also possible to design Kingspan SFS sections Assumes a design deflection limit under imposed load of
to form the primary load bearing structural framing span/360 for the primary frame. This should be confirmed with
the primary frame engineer

1
Solutions technical department. In oversail framing, Building Solutions will identify potential CDM risks
the deflection tolerance is generally accommodated to the named individual within the project team. It is
within the supporting bracketry and is therefore not the responsibility of the Installer to provide the
limited by the SFS. contact details of this individual to Kingspan Steel
Building Solutions.
Building Regulation Requirements
The installer should refer to the main contractor and When Kingspan Steel Building Solutions recognises
the architect to ensure that the requirements under a hazard to health and safety that cannot be
Building Regulations for areas such as air tightness, avoided through design, the hazard and proposed
fire resistance, thermal bridging and acoustic mitigation is identified on the drawings using the
protection are met before construction begins. following symbol:
When clad in suitable materials and linings, SFS
constructions can achieve performances in excess
to those required by the current regulations. As the
performance is governed by the cladding and
linings designed and supplied by others, Kingspan Figure 1 - CDM Hazard Identification
Steel Building Solutions cannot provide specific
guidance in these areas. If you require further A description of the hazard is then written into the
guidance, please consider use of our full through legend of the drawings. The most frequently
wall system - KingBuild System (KBS). identified specific risks are:
Multiple different stud systems / gauges
1.3 Design Guidance specified on drawing installer to implement
sufficient QA checks to ensure compliance with
Kingspan Steel Building Solutions offer guidance on scheme. Consider requesting Kingspan site
specific issues that affect the design, specification inspection.
and installation of the SFS system. Detailed Long span studs installer to prepare
guidance on issues can be found at: adequate method statement for handling of
http://www.kingspanpanels.co.uk/sbs. high span studs. Consider mechanical lifting
equipment.
Guidance notes published by Kingspan Steel Heavy lifting installer to prepare adequate
Building Solutions are recommendations and cover method statement for handling heavy materials.
the following main areas; SFS & Setting Out; SFS &
Consider mechanical lifting equipment.
Sustainability; SFS & Thermal Performance, SFS & Large structural openings lintels, cills and
Deflection; SFS & Wind Loadings.
jambs must be formed with continuous (NOT
spliced) members. Installer to ensure specific
section lengths ordered as required.
Edge protection required SFS cill too low to
1.4 Construction Design Management offer edge protection to BS EN 13374:2004.
The Construction Design Management (CDM) Main contractor to provide additional edge
regulations 2007 redefined the responsibilities and protection system.
guidance for system suppliers and designers on all
construction projects in the UK. Wherever possible, For further information, please refer to the SFS
Kingspan Steel Building Solutions will take Designers Risk Assessment and the SFS
measures to design out any risk to the installer Installation Manual.
during construction of the SFS. Kingspan Steel

2
2 SFS STANDARD COMPONENTS
2.1 Basic Components
C section and U section components are formed from pre-hot dipped galvanised steel to BS EN 10346:2009,
2 2
Grade S390 + zinc coating Z275 g/m . Guaranteed minimum yield strength = 390N/mm .

Ancillary components including Angles, Cleats, Brackets and Z Bars are formed from pre-hot dipped
2
galvanised steel to BS EN 10346:2009, Grade S275 + zinc coating Z275 g/m . Guaranteed minimum yield
2
strength = 275N/mm .

U Section Track C Section Stud

Angles, Cleats & Brackets Z Bar

Flat Straps

N.B. All thicknesses given in this manual are the overall nominal thickness, including galvanised coating.

3
2.2 Kingspan Section Range

All sections and ancillaries provided by Kingspan have a unique reference. The table below gives a guide to
what these references mean;

C 100 050 120


C Section 100mm web (W) 50mm leg (F) 1.2mm thickness (T)

U 104 055 120


U Section 104mm web (W) 55mm leg (F) 1.2mm thickness (T)

FS 100 ~ 120
Flat Strap 100mm width (A) ~ 1.2mm thickness (T)

B 135 105 60
Bracket 135mm leg (A) 105mm leg (B) 6.0mm thickness (T)

L 70 50 20
Angle Section 70mm leg (A) 50mm leg (B) 2.0mm thickness (T)

L 70 50 20 L
Angle Section 70mm leg (A) 50mm leg (B) 2.0mm thickness (T) Stock Lengths 3.0m

2.3 Secondary Products

The table below gives the sections and products other than standard C and U sections manufactured by
Kingspan:

T
Section Ref. Weight (kg/m) A (mm) B (mm) C (mm)
(mm)
Angles & Cleats
L70502 ~ 50 50 70 2.0
L100502 ~ 50 50 100 2.0
L150502 ~ 50 50 150 2.0
L200502 ~ 50 50 200 2.0
L250502 ~ 50 50 250 2.0
L300502 ~ 50 50 300 2.0
L50502L ~ 50 50 3000 2.0
L100502L ~ 100 50 3000 2.0
L1501002L ~ 150 100 3000 2.0
Brackets
B13510560* ~ 135 105 95 6.0
B808030* ~ 80 80 80 3.0
KHC9524A* ~ 60 80 95 2.4
KHC9528B* ~ 135 80 95 2.8
Strap Products
FS10012 ~ 100 ~ ~ 1.2
FS3809 ~ 38 ~ ~ 0.9
Z Bar Products
Z40404016 ~ 40 40 40 1.6

*Products include pre-punched holes. Contact Kingspan for further information.

4
2.4 C Section Range4
2.4.1 To BS5950-5:1998
Dimensions Gross Section Major Axis Bending Minor Axis Bending Compression
Internal Galv Ixx Zxx Mcy Web Mcy Web
Section Mass W F Li T Area Ixx Iyy rx ry Zxx Zyy P0 es
radius coating 2 4 4 3 3 Effective Effective 2 Comp Tension Q
Reference (kg/m) (mm) (mm) (mm) (mm) (mm ) (cm ) (cm ) (cm) (cm) (cm ) (cm ) (N/mm ) (mm)
ri (mm) (mm) (cm4) (cm3) (kNm) (kNm)

C070050150 2.09 70.00 50.00 10.00 1.50 3.00 0.04 266.34 22.91 9.08 2.92 1.84 6.69 2.94 22.49 6.48 390.00 1.53 1.15 1.18 0.89
C070070200 3.48 70.00 70.00 14.00 2.00 4.00 0.04 442.83 39.88 29.83 2.97 2.57 11.73 7.42 38.95 11.25 390.00 3.70 2.89 0.41 0.93
C100050120 1.98 100.00 50.00 10.00 1.20 2.40 0.04 252.06 41.32 8.31 4.07 1.82 8.36 2.48 38.95 7.59 366.21 1.13 0.97 4.36 0.67
C100060120 2.21 100.00 60.00 12.00 1.20 2.40 0.04 280.86 47.69 13.70 4.15 2.22 9.65 3.53 42.61 8.02 366.21 1.51 1.34 4.65 0.61
C100070120 2.43 100.00 70.00 14.00 1.20 2.40 0.04 309.66 53.99 20.83 4.21 2.61 10.93 4.75 45.62 8.30 366.21 1.93 1.72 4.77 0.56
C100070160 3.20 100.00 70.00 14.00 1.60 3.20 0.04 407.57 71.57 27.47 4.19 2.59 14.55 6.30 66.30 12.79 385.54 2.92 2.45 3.39 0.73
C100070200 3.95 100.00 70.00 14.00 2.00 4.00 0.04 502.83 88.65 33.84 4.17 2.58 18.09 7.79 86.50 17.35 390.00 3.98 3.04 2.04 0.87
C125050120 2.22 125.00 50.00 10.00 1.20 2.40 0.04 282.06 68.86 8.92 4.97 1.79 11.12 2.54 65.28 10.20 347.37 1.14 0.98 5.83 0.60
C125060120 2.44 125.00 60.00 12.00 1.20 2.40 0.04 310.86 78.98 14.75 5.08 2.19 12.76 3.63 71.25 10.80 347.37 1.52 1.36 6.35 0.56
C125070120 2.67 125.00 70.00 14.00 1.20 2.40 0.04 339.66 89.01 22.48 5.16 2.59 14.38 4.89 76.30 11.21 347.37 1.94 1.76 6.62 0.52
C125070160 3.52 125.00 70.00 14.00 1.60 3.20 0.04 447.57 118.22 29.65 5.14 2.58 19.16 6.48 110.10 17.03 371.52 2.93 2.51 5.31 0.68
C125070200 4.35 125.00 70.00 14.00 2.00 4.00 0.04 552.83 146.69 36.54 5.12 2.56 23.85 8.02 143.12 22.89 385.82 4.01 3.13 3.88 0.80
C150050120 2.45 150.00 50.00 10.00 1.20 2.40 0.04 312.06 105.11 9.42 5.85 1.75 14.13 2.59 100.53 13.16 328.52 1.14 1.00 7.00 0.55
C150060120 2.67 150.00 60.00 12.00 1.20 3.00 0.04 339.62 119.85 15.63 5.98 2.16 16.11 3.70 109.13 13.87 328.52 1.53 1.38 7.75 0.52
C150070120 2.91 150.00 70.00 14.00 1.20 2.40 0.04 369.66 134.48 23.87 6.08 2.56 18.08 4.99 116.71 14.41 328.52 1.95 1.78 8.21 0.48
C150070160 3.83 150.00 70.00 14.00 1.60 3.20 0.04 487.57 178.84 31.49 6.07 2.55 24.10 6.62 167.29 21.61 357.51 2.94 2.55 6.97 0.63
C150070200 4.74 150.00 70.00 14.00 2.00 4.00 0.04 602.83 222.19 38.81 6.05 2.53 30.03 8.19 216.98 28.87 374.66 4.02 3.19 5.56 0.74
C200050120 2.92 200.00 50.00 10.00 1.20 2.40 0.04 372.06 207.35 10.17 7.53 1.67 20.86 2.65 201.24 19.91 290.82 1.16 1.01 8.73 0.47
C200060120 3.15 200.00 60.00 12.00 1.20 2.40 0.04 400.86 233.95 16.99 7.71 2.08 23.54 3.80 218.12 21.08 290.82 1.55 1.40 9.89 0.45
C200070120 3.38 200.00 70.00 14.00 1.20 2.40 0.04 429.66 260.38 26.07 7.86 2.49 26.20 5.14 232.06 21.86 290.82 1.98 1.81 10.72 0.42
C200070160 4.46 200.00 70.00 14.00 1.60 3.20 0.04 567.57 346.86 34.40 7.84 2.47 34.97 6.82 328.47 32.05 329.48 2.97 2.61 9.57 0.54
C200070200 5.52 200.00 70.00 14.00 2.00 4.00 0.04 702.83 431.67 42.40 7.82 2.45 43.60 8.44 423.38 42.26 352.36 4.04 3.29 8.24 0.64
C250070120 3.85 250.00 70.00 14.00 1.20 2.40 0.04 489.66 438.95 27.75 9.57 2.41 35.29 5.25 401.63 30.74 253.13 2.01 1.83 12.58 0.38
C250070160 5.09 250.00 70.00 14.00 1.60 3.20 0.04 647.57 585.39 36.61 9.55 2.39 47.13 6.95 561.54 44.15 301.45 3.00 2.64 11.49 0.48
C250070200 6.31 250.00 70.00 14.00 2.00 4.00 0.04 802.83 729.34 45.11 9.53 2.37 58.82 8.61 718.82 57.48 330.05 4.07 3.36 10.21 0.57
C300070200 7.10 300.00 70.00 14.00 2.00 4.00 0.04 902.83 1127.44 47.24 11.18 2.29 75.67 8.73 1115.50 74.42 307.74 4.11 3.40 11.71 0.51

4
Please refer to web site to ensure you are using an up to date copy of the section properties. Further sections are available upon request. Please contact your Area Sales Manager for further details.

5
2.4.2 To BS-EN-1993-1-3:2006

Dimensional Gross Section Major axis bending Minor Axis Bending Compression
Mc,z
Internal Galv Gross Iyy in Wel,yy in Mcz Web
Section Mass W F Li T Iyy Izz iy iz Wel,yy Wel,zz Web eNy
radius coating 3 Area 4 4 3 3 Bending Bending Tension Q
Reference (Kg/m) (mm) (mm) (mm) (mm) (x10 ) 2 (cm ) (cm ) (cm) (cm) (cm ) (cm ) 4 3 Comp (mm)
ri (mm) (mm) (mm ) (cm ) (cm ) (kNm)
(kNm)
C070050150 2.09 70.00 50.00 10.00 1.50 3.00 0.04 28.04 266.34 22.91 9.08 2.96 1.86 6.31 2.78 20.91 5.73 1.46 0.91 -2.07 0.76
C070070200 3.48 70.00 70.00 14.00 2.00 4.00 0.04 29.91 442.83 39.88 29.83 3.02 2.61 11.03 6.98 36.25 9.94 3.62 2.38 -4.63 0.82
C100050120 1.98 100.00 50.00 10.00 1.20 2.40 0.04 19.18 252.06 41.33 8.31 4.11 1.84 8.04 2.39 35.30 6.49 1.11 0.65 -2.07 0.54
C100060120 2.21 100.00 60.00 12.00 1.20 2.40 0.04 17.26 280.86 47.69 13.70 4.18 2.24 9.32 3.41 38.52 6.85 1.49 0.88 -3.97 0.51
C100070120 2.43 100.00 70.00 14.00 1.20 2.40 0.04 15.68 309.66 53.99 20.83 4.24 2.63 10.59 4.61 41.61 7.19 1.91 1.13 -6.06 0.48
C100070160 3.20 100.00 70.00 14.00 1.60 3.20 0.04 21.04 407.57 71.58 27.48 4.23 2.62 13.94 6.03 60.64 11.07 2.83 1.75 -4.81 0.61
C100070200 3.95 100.00 70.00 14.00 2.00 4.00 0.04 26.46 502.83 88.65 33.85 4.23 2.61 17.13 7.38 80.02 15.23 3.80 2.38 -3.10 0.73
C125050120 2.22 125.00 50.00 10.00 1.20 2.40 0.04 17.19 282.06 68.87 8.93 5.02 1.81 10.74 2.46 56.57 8.08 1.12 0.62 -0.82 0.49
C125060120 2.44 125.00 60.00 12.00 1.20 2.40 0.04 15.62 310.86 78.99 14.76 5.12 2.21 12.36 3.52 61.69 8.56 1.51 0.85 -2.63 0.46
C125070120 2.67 125.00 70.00 14.00 1.20 2.40 0.04 14.32 339.66 89.02 22.49 5.20 2.61 13.97 4.75 66.57 9.01 1.93 1.12 -4.54 0.44
C125070160 3.52 125.00 70.00 14.00 1.60 3.20 0.04 19.20 447.57 118.23 29.66 5.19 2.60 18.43 6.23 99.92 14.59 2.87 1.71 -3.83 0.55
C125070200 4.35 125.00 70.00 14.00 2.00 4.00 0.04 24.14 552.83 146.70 36.55 5.19 2.59 22.70 7.63 131.88 20.01 3.88 2.34 -1.91 0.67
C150050120 2.45 150.00 50.00 10.00 1.20 2.40 0.04 15.57 312.06 105.13 9.42 5.89 1.76 13.69 2.51 83.20 9.66 1.13 0.60 0.16 0.44
C150060120 2.67 150.00 60.00 12.00 1.20 3.00 0.04 17.84 339.62 119.87 15.63 6.03 2.18 15.54 3.57 90.80 10.30 1.52 0.84 -1.48 0.42
C150070120 2.91 150.00 70.00 14.00 1.20 2.40 0.04 13.18 369.66 134.50 23.88 6.12 2.58 17.60 4.86 97.74 10.84 1.94 1.11 -3.23 0.40
C150070160 3.83 150.00 70.00 14.00 1.60 3.20 0.04 17.66 487.57 178.86 31.50 6.12 2.57 23.25 6.39 148.38 17.82 2.90 1.66 -2.48 0.51
C150070200 4.74 150.00 70.00 14.00 2.00 4.00 0.04 22.19 602.83 222.21 38.82 6.12 2.56 28.70 7.83 199.20 25.15 3.93 2.30 -0.89 0.61
C200050120 2.92 200.00 50.00 10.00 1.20 2.40 0.04 13.10 372.06 207.38 10.18 7.58 1.68 20.32 2.58 154.16 12.96 1.14 0.58 1.65 0.37
C200060120 3.15 200.00 60.00 12.00 1.20 2.40 0.04 12.17 400.86 233.98 16.99 7.76 2.09 22.97 3.71 167.27 13.78 1.53 0.82 0.32 0.36
C200070120 3.38 200.00 70.00 14.00 1.20 2.40 0.04 11.37 429.66 260.42 26.08 7.91 2.50 25.60 5.03 179.29 14.50 1.96 1.08 -1.09 0.34
C200070160 4.46 200.00 70.00 14.00 1.60 3.20 0.04 15.22 567.57 346.91 34.41 7.90 2.49 33.91 6.61 272.49 23.64 2.94 1.57 -0.33 0.44
C200070200 5.52 200.00 70.00 14.00 2.00 4.00 0.04 19.11 702.83 431.72 42.40 7.90 2.48 41.94 8.12 376.30 34.85 3.99 2.20 0.71 0.52
C250070120 3.85 250.00 70.00 14.00 1.20 2.40 0.04 9.99 489.66 439.00 27.75 9.62 2.42 34.58 5.14 287.20 18.18 1.97 1.05 0.53 0.30
C250070160 5.09 250.00 70.00 14.00 1.60 3.20 0.04 13.37 647.57 585.46 36.61 9.61 2.40 45.88 6.77 439.10 29.66 2.96 1.54 1.33 0.38
C250070200 6.31 250.00 70.00 14.00 2.00 4.00 0.04 16.78 802.83 729.42 45.12 9.61 2.39 56.85 8.32 605.92 43.37 4.03 2.10 2.23 0.45
C300070200 7.10 300.00 70.00 14.00 2.00 4.00 0.04 14.96 902.83 1127.58 47.24 11.27 2.31 73.41 8.47 894.19 51.85 4.05 2.00 3.48 0.40

6
2.5 U Section Range5
2.5.1 To BS5950-5:1998

Dimensions Gross Section Major Axis Bending Minor Axis Bending Compression
Internal Galv Ixx Zxx Mcy Web Mcy Web
Section Mass W F Li T Area Ixx Iyy rx ry Zxx Zyy P0 es
radius coating Effective Effective Comp Tension Q
Reference (kg/m) (mm) (mm) (mm) (mm) (mm2) (cm4) (cm4) (cm) (cm) (cm3) (cm3) 4 3 (N/mm2) (mm)
ri (mm) (mm) (cm ) (cm ) (kNm) (kNm)

U074055150 2.10 74.00 55.00 ~ 1.50 3.00 0.04 266.67 25.45 8.55 3.10 1.80 7.02 2.25 19.49 4.59 390.00 1.43 0.32 -4.27 0.49
U074069180 2.89 74.00 69.00 ~ 1.80 3.60 0.04 368.17 36.76 18.88 3.17 2.27 10.18 4.12 27.52 6.39 390.00 2.61 0.56 -3.42 0.56
U074069200 3.20 74.00 69.00 ~ 2.00 4.00 0.04 407.42 40.64 20.93 3.16 2.27 11.29 4.57 31.51 7.46 390.00 2.95 0.74 -2.14 0.60
U104055120 1.97 104.00 55.00 ~ 1.20 2.40 0.04 250.83 43.83 7.64 4.23 1.76 8.53 1.89 32.69 5.43 363.20 1.05 0.18 -7.12 0.31
U104067180 3.26 104.00 67.00 ~ 1.80 3.60 0.04 414.97 76.40 19.54 4.30 2.18 14.95 4.12 58.75 9.88 389.92 2.57 0.57 -6.42 0.44
U104067200 3.63 104.00 67.00 ~ 2.00 4.00 0.04 461.42 84.61 21.66 4.30 2.17 16.59 4.57 67.06 11.46 390.00 2.96 0.75 -5.35 0.48
U129055120 2.21 129.00 55.00 ~ 1.20 2.40 0.04 280.83 71.69 8.15 5.11 1.72 11.22 1.95 54.76 7.44 344.35 1.06 0.19 -7.04 0.26
U129068180 3.64 129.00 68.00 ~ 1.80 3.60 0.04 463.57 125.70 21.79 5.23 2.18 19.76 4.37 97.81 13.37 377.50 2.64 0.58 -7.55 0.37
U129068200 4.04 129.00 68.00 ~ 2.00 4.00 0.04 513.42 139.34 24.16 5.22 2.17 21.94 4.85 111.17 15.40 384.03 3.05 0.76 -6.77 0.41
U154055120 2.44 154.00 55.00 ~ 1.20 2.40 0.04 310.83 108.13 8.56 5.97 1.68 14.15 1.99 84.30 9.73 325.50 1.06 0.19 -6.74 0.23
U154067180 3.97 154.00 67.00 ~ 1.80 3.60 0.04 504.97 186.42 22.06 6.10 2.10 24.50 4.35 147.85 17.15 365.07 2.58 0.58 -7.64 0.32
U154067200 4.40 154.00 67.00 ~ 2.00 4.00 0.04 559.42 206.76 24.46 6.10 2.10 27.21 4.83 167.70 19.68 372.88 2.98 0.76 -7.08 0.35
U204055120 2.91 204.00 55.00 ~ 1.20 2.40 0.04 370.83 210.35 9.18 7.63 1.59 20.74 2.05 169.67 15.08 287.81 1.08 0.19 -5.43 0.20
U204067180 4.68 204.00 67.00 ~ 1.80 3.60 0.04 594.97 359.00 23.83 7.81 2.01 35.51 4.49 291.95 25.98 340.23 2.60 0.58 -7.40 0.26
U204067200 5.18 204.00 67.00 ~ 2.00 4.00 0.04 659.42 398.47 26.42 7.80 2.01 39.45 4.99 330.05 29.64 350.57 3.00 0.77 -7.05 0.28
U254055120 3.39 254.00 55.00 ~ 1.20 2.40 0.04 430.83 357.74 9.63 9.24 1.52 28.30 2.09 296.55 21.50 250.11 1.09 0.19 -4.22 0.18
U254067180 5.38 254.00 67.00 ~ 1.80 3.60 0.04 684.97 605.14 25.14 9.46 1.93 47.99 4.59 502.46 36.37 315.38 2.62 0.58 -5.89 0.23
U254067200 5.97 254.00 67.00 ~ 2.00 4.00 0.04 759.42 672.01 27.87 9.45 1.92 53.33 5.10 566.58 41.32 328.26 3.02 0.77 -5.55 0.26
U304067200 6.76 304.00 67.00 ~ 2.00 4.00 0.04 859.42 1039.62 28.99 11.06 1.85 68.85 5.18 889.85 54.71 305.95 3.04 0.77 -4.35 0.23

5
Please refer to web site to ensure you are using an up to date copy of the section properties. Further sections are available upon request. Please contact your Area Sales Manager for further details.

7
2.5.2 To BS-EN-1993-1-3:2006

Dimensional Gross Section Major axis bending Minor Axis Bending Compression
Internal Galv Gross Iyy in Wel,yy in Mc,z Web Mcz Web
Section Mass W F Li T Iyy Izz iy iz Wel,yy Wel,zz eNy
radius coating Area Bending Bending Comp Tension Q
Reference (Kg/m) (mm) (mm) (mm) (mm) (x103) 2 (cm4) (cm4) (cm) (cm) (cm3) (cm3) 4 3 (mm)
ri (mm) (mm) (mm ) (cm ) (cm ) (kNm) (kNm)

U074055150 2.10 74.00 55.00 ~ 1.50 3.00 0.04 0.00 266.67 25.45 8.55 3.10 1.80 7.02 2.25 17.22 3.84 1.37 0.35 -12.05 0.50

U074069180 2.89 74.00 69.00 ~ 1.80 3.60 0.04 0.00 368.17 36.76 18.89 3.17 2.27 10.18 4.12 23.81 5.19 2.51 0.66 -17.00 0.51

U074069200 3.20 74.00 69.00 ~ 2.00 4.00 0.04 0.00 407.42 40.64 20.94 3.16 2.27 11.29 4.57 27.33 6.06 2.87 0.80 -16.34 0.56

U104055120 1.97 104.00 55.00 ~ 1.20 2.40 0.04 0.00 250.83 43.85 7.65 4.23 1.77 8.53 1.89 27.91 4.31 1.04 0.21 -10.75 0.36

U104067180 3.26 104.00 67.00 ~ 1.80 3.60 0.04 0.00 414.97 76.41 19.55 4.30 2.18 14.95 4.12 52.56 8.42 2.48 0.61 -13.66 0.48

U104067200 3.63 104.00 67.50 ~ 2.00 4.00 0.04 0.00 461.42 85.14 22.12 4.30 2.19 16.69 4.64 60.24 9.78 2.88 0.75 -13.27 0.52

U129055120 2.21 129.00 55.00 ~ 1.20 2.40 0.04 0.00 280.83 71.71 8.16 5.11 1.72 11.22 1.95 44.63 5.48 1.05 0.20 -9.32 0.33

U129068180 3.64 129.00 68.00 ~ 1.80 3.60 0.04 0.00 463.57 125.72 21.80 5.23 2.18 19.77 4.37 88.61 11.62 2.58 0.60 -12.35 0.44

U129068200 4.04 129.00 68.00 ~ 2.00 4.00 0.04 0.00 513.42 139.36 24.17 5.22 2.17 21.95 4.85 101.01 13.41 2.96 0.74 -11.79 0.48

U154055120 2.44 154.00 55.00 ~ 1.20 2.40 0.04 0.00 310.83 108.15 8.57 5.97 1.68 14.16 1.99 65.69 6.68 1.05 0.19 -8.15 0.30

U154067180 3.97 154.00 67.00 ~ 1.80 3.60 0.04 0.00 504.97 186.46 22.07 6.10 2.10 24.50 4.35 131.52 14.41 2.54 0.57 -10.56 0.41

U154067200 4.40 154.00 67.00 ~ 2.00 4.00 0.04 0.00 559.42 206.80 24.47 6.10 2.10 27.21 4.83 154.17 17.43 2.92 0.71 -10.03 0.45

U204055120 2.91 204.00 55.00 ~ 1.20 2.40 0.04 0.00 370.83 210.39 9.19 7.63 1.59 20.75 2.05 121.50 9.15 1.06 0.18 -6.37 0.26

U204067180 4.68 204.00 67.00 ~ 1.80 3.60 0.04 0.00 594.97 359.07 23.84 7.81 2.01 35.52 4.50 243.99 19.72 2.57 0.54 -8.36 0.35

U204067200 5.18 204.00 67.00 ~ 2.00 4.00 0.04 0.00 659.42 398.55 26.43 7.80 2.01 39.46 4.99 287.27 23.93 2.96 0.67 -7.84 0.39

U254055120 3.39 254.00 55.00 ~ 1.20 2.40 0.04 0.00 430.83 357.82 9.64 9.24 1.52 28.31 2.09 196.47 11.70 1.07 0.17 -5.08 0.22

U254067180 5.38 254.00 67.00 ~ 1.80 3.60 0.04 0.00 684.97 605.25 25.15 9.46 1.93 48.00 4.59 395.69 25.19 2.59 0.51 -6.71 0.31

U254067200 5.97 254.00 67.00 ~ 2.00 4.00 0.04 0.00 759.42 672.13 27.88 9.45 1.92 53.34 5.10 466.77 30.56 2.98 0.65 -6.20 0.34

U304067200 6.76 304.00 67.00 ~ 2.00 4.00 0.04 0.00 859.42 1039.79 29.00 11.06 1.85 68.86 5.18 695.56 37.37 3.00 0.62 -4.94 0.31

8
2.6 Ancillary Products

The following products are supplied by Kingspan Steel Building Solutions and its agents. These components
are not manufactured by Kingspan Steel Building Solutions;

Order Ref. Box Qty W (mm)


Deflection Head Bracket
DHB70 100 70
DHB100 100 100
DHB150 100 150
DHB200 100 200
DHB250 100 250
DHB300 100 300

2.7 Span Tables

The following span tables show the maximum span for each stud section under different applied windloads,
effective lengths and span deflection ratios. When using the tables please take into consideration the following
notes:
The values shown in each table are the maximum spans in metres of each stud section.
The section properties used to form the tables are in accordance with BS5950: Part 5:1998. Design is
based on SCI assessed methodology (SCI Assessed Report RT1439 April 2012).
The span tables apply to SFS Infill sections only. They do not apply for oversail or load bearing sections.
Spans are not limited by the end conditions and therefore these must be checked separately. Spans in bold
and italic highlight spans to which the standard stud/track end condition must be checked.
Wind loads are assumed to be uniformly distributed loads only.
No allowance has been made for barrier loading or any other additional imposed load.
Span tables do not consider the axial capacity of the stud sections.
Allowable deflection ratios depend on the type of finishes being applied to the SFS. For further advice seek
specialist manufacturers guidance.
If in doubt on how to apply these tables, please seek advice from Kingspan Steel Building Solutions.
Span tables are to be used for guidance only.

Kingspan accepts no liability for the use of its published span tables on live schemes.

Schemes should be referred to Kingspan for design and engineering calculations (at agreed costs) prior to
material purchase in all instances.

9
SFS Span Tables Studs at 600 centres
Deflection Ratio: L/360 Deflection Ratio: L/360
Effective Length: 0.85 x L Effective Length: 0.5 x L (Mid-Span Noggins)
Unfactored Wind load (kN/m2) Unfactored Wind load (kN/m2)
Stud Section 0.6 0.8 1 1.2 1.4 1.6 1.8 2 Stud Section 0.6 0.8 1 1.2 1.4 1.6 1.8 2
C070050150 3.03 2.75 2.56 2.40 2.28 2.18 2.10 2.03 C070050150 3.03 2.75 2.56 2.40 2.28 2.18 2.10 2.03
C070070200 3.64 3.31 3.07 2.89 2.75 2.63 2.53 2.44 C070070200 3.64 3.31 3.07 2.89 2.75 2.63 2.53 2.44
C100050120 3.68 3.35 3.11 2.93 2.78 2.66 2.56 2.47 C100050120 3.69 3.35 3.11 2.93 2.78 2.66 2.56 2.47
C100060120 3.87 3.51 3.26 3.07 2.92 2.79 2.68 2.59 C100060120 3.87 3.51 3.26 3.07 2.92 2.79 2.68 2.59
C100070120 4.03 3.66 3.40 3.20 3.04 2.91 2.80 2.70 C100070120 4.03 3.66 3.40 3.20 3.04 2.91 2.80 2.70
C100070160 4.43 4.02 3.74 3.52 3.34 3.19 3.07 2.96 C100070160 4.43 4.02 3.74 3.52 3.34 3.19 3.07 2.96
C100070200 4.76 4.32 4.01 3.78 3.59 3.43 3.30 3.18 C100070200 4.76 4.32 4.01 3.78 3.59 3.43 3.30 3.18
C125050120 3.95 3.66 3.45 3.28 3.15 3.04 2.95 2.87 C125050120 4.37 3.97 3.69 3.47 3.30 3.15 3.03 2.93
C125060120 4.46 4.13 3.86 3.63 3.45 3.30 3.17 3.06 C125060120 4.58 4.16 3.86 3.63 3.45 3.30 3.17 3.06
C125070120 4.76 4.33 4.02 3.78 3.59 3.43 3.30 3.19 C125070120 4.76 4.33 4.02 3.78 3.59 3.43 3.30 3.19
C125070160 5.24 4.76 4.42 4.16 3.95 3.78 3.63 3.50 C125070160 5.24 4.76 4.42 4.16 3.95 3.78 3.63 3.50
C125070200 5.63 5.11 4.74 4.47 4.24 4.06 3.90 3.77 C125070200 5.63 5.11 4.75 4.47 4.24 4.06 3.90 3.77
C150050120 4.18 3.88 3.65 3.48 3.34 3.23 3.13 3.04 C150050120 5.03 4.57 4.25 4.00 3.80 3.63 3.49 3.37
C150060120 4.73 4.39 4.14 3.94 3.78 3.65 3.54 3.44 C150060120 5.26 4.78 4.44 4.17 3.97 3.79 3.65 3.52
C150070120 5.25 4.86 4.59 4.34 4.12 3.94 3.79 3.66 C150070120 5.47 4.97 4.61 4.34 4.12 3.94 3.79 3.66
C150070160 5.69 5.27 4.97 4.73 4.53 4.33 4.17 4.02 C150070160 6.01 5.46 5.07 4.77 4.53 4.33 4.17 4.02
C150070200 6.10 5.64 5.31 5.05 4.84 4.66 4.48 4.32 C150070200 6.46 5.87 5.45 5.13 4.87 4.66 4.48 4.32
C200050120 4.57 4.24 4.00 3.82 3.66 3.54 3.43 3.34 C200050120 5.89 5.46 5.15 4.91 4.71 4.54 4.38 4.23
C200060120 5.18 4.81 4.54 4.33 4.16 4.01 3.89 3.78 C200060120 6.57 5.97 5.54 5.22 4.96 4.74 4.56 4.40
C200070120 5.76 5.34 5.04 4.81 4.62 4.46 4.32 4.20 C200070120 6.81 6.19 5.75 5.40 5.14 4.91 4.72 4.56
C200070160 6.23 5.78 5.45 5.19 4.98 4.81 4.66 4.54 C200070160 7.49 6.81 6.32 5.95 5.65 5.40 5.20 5.02
C200070200 6.65 6.15 5.80 5.52 5.30 5.12 4.96 4.82 C200070200 8.06 7.32 6.80 6.40 6.08 5.81 5.59 5.40
C250070120 6.18 5.74 5.42 5.16 4.96 4.79 4.65 4.52 C250070120 7.98 7.37 6.84 6.43 6.11 5.85 5.62 5.43
C250070160 6.68 6.19 5.84 5.57 5.35 5.17 5.01 4.87 C250070160 8.60 7.98 7.52 7.08 6.73 6.43 6.19 5.97
C250070200 7.11 6.59 6.21 5.92 5.68 5.48 5.32 5.17 C250070200 9.13 8.46 7.98 7.60 7.24 6.92 6.66 6.43
C300070200 7.51 6.96 6.56 6.26 6.01 5.80 5.63 5.47 C300070200 9.66 8.96 8.45 8.05 7.73 7.46 7.24 7.03

When using these tables, please refer to notes in Section 2.7. Note: Spans highlighted in Bold and Italic may require non-standard stud/track end conditions please check separately.

10
SFS Span Tables Studs at 400 centres
Deflection Ratio: L/360 Deflection Ratio: L/360
Effective Length: 0.85 x L Effective Length: 0.5 x L (Mid-Span Noggins)

Unfactored Wind load (kN/m2) Unfactored Wind load (kN/m2)


Stud Section 0.6 0.8 1 1.2 1.4 1.6 1.8 2 Stud Section 0.6 0.8 1 1.2 1.4 1.6 1.8 2

C070050150 3.47 3.15 2.92 2.75 2.61 2.50 2.40 2.32 C070050150 3.47 3.15 2.92 2.75 2.61 2.50 2.40 2.32
C070070200 4.17 3.79 3.52 3.31 3.14 3.01 2.89 2.79 C070070200 4.17 3.79 3.52 3.31 3.14 3.01 2.89 2.79
C100050120 4.10 3.80 3.56 3.35 3.18 3.04 2.93 2.83 C100050120 4.22 3.83 3.56 3.35 3.18 3.04 2.93 2.83
C100060120 4.43 4.02 3.73 3.51 3.34 3.19 3.07 2.96 C100060120 4.43 4.02 3.73 3.51 3.34 3.19 3.07 2.96
C100070120 4.61 4.19 3.89 3.66 3.48 3.33 3.20 3.09 C100070120 4.61 4.19 3.89 3.66 3.48 3.33 3.20 3.09
C100070160 5.07 4.61 4.28 4.02 3.82 3.66 3.51 3.39 C100070160 5.07 4.61 4.28 4.02 3.82 3.66 3.51 3.39
C100070200 5.44 4.95 4.59 4.32 4.10 3.93 3.77 3.64 C100070200 5.44 4.95 4.59 4.32 4.10 3.93 3.77 3.64
C125050120 4.40 4.07 3.84 3.66 3.51 3.39 3.28 3.19 C125050120 5.00 4.55 4.22 3.97 3.77 3.61 3.47 3.35
C125060120 4.97 4.60 4.34 4.13 3.95 3.78 3.63 3.51 C125060120 5.24 4.76 4.42 4.16 3.95 3.78 3.63 3.51
C125070120 5.45 4.95 4.60 4.33 4.11 3.93 3.78 3.65 C125070120 5.45 4.95 4.60 4.33 4.11 3.93 3.78 3.65
C125070160 5.99 5.44 5.05 4.76 4.52 4.32 4.16 4.01 C125070160 5.99 5.44 5.05 4.76 4.52 4.32 4.16 4.01
C125070200 6.44 5.85 5.43 5.11 4.85 4.64 4.46 4.31 C125070200 6.44 5.85 5.43 5.11 4.85 4.64 4.46 4.31
C150050120 4.65 4.31 4.07 3.88 3.72 3.59 3.48 3.39 C150050120 5.76 5.23 4.86 4.57 4.34 4.15 3.99 3.86
C150060120 5.26 4.88 4.60 4.39 4.21 4.07 3.94 3.83 C150060120 6.02 5.47 5.08 4.78 4.54 4.34 4.17 4.03
C150070120 5.83 5.41 5.10 4.86 4.67 4.51 4.34 4.19 C150070120 6.25 5.68 5.28 4.96 4.72 4.51 4.34 4.19
C150070160 6.35 5.88 5.54 5.27 5.06 4.88 4.73 4.60 C150070160 6.88 6.25 5.80 5.46 5.19 4.96 4.77 4.61
C150070200 6.81 6.30 5.92 5.64 5.41 5.21 5.05 4.91 C150070200 7.39 6.72 6.24 5.87 5.58 5.33 5.13 4.95
C200050120 5.08 4.71 4.45 4.24 4.07 3.94 3.82 3.71 C200050120 6.55 6.08 5.73 5.46 5.24 5.06 4.91 4.77
C200060120 5.76 5.34 5.04 4.81 4.62 4.46 4.33 4.21 C200060120 7.43 6.83 6.34 5.97 5.67 5.42 5.22 5.04
C200070120 6.40 5.94 5.60 5.34 5.13 4.96 4.81 4.67 C200070120 7.80 7.08 6.58 6.19 5.88 5.62 5.40 5.22
C200070160 6.93 6.43 6.06 5.78 5.55 5.35 5.19 5.05 C200070160 8.58 7.79 7.23 6.81 6.47 6.19 5.95 5.74
C200070200 7.41 6.86 6.46 6.15 5.91 5.70 5.52 5.37 C200070200 9.23 8.38 7.78 7.32 6.96 6.65 6.40 6.18
C250070120 6.86 6.37 6.02 5.74 5.51 5.32 5.16 5.02 C250070120 8.87 8.23 7.76 7.37 6.99 6.69 6.43 6.21
C250070160 7.43 6.89 6.50 6.19 5.95 5.75 5.57 5.42 C250070160 9.57 8.87 8.37 7.98 7.66 7.36 7.08 6.84
C250070200 7.92 7.33 6.91 6.59 6.32 6.10 5.92 5.76 C250070200 10.16 9.42 8.88 8.46 8.12 7.84 7.60 7.36
C300070200 8.35 7.74 7.30 6.96 6.68 6.45 6.26 6.09 C300070200 10.74 9.96 9.40 8.96 8.60 8.31 8.05 7.83

When using these tables, please refer to notes in Section 2.7. Note: Spans highlighted in Bold and Italic may require non-standard stud/track end conditions please check separately.

11
SFS Span Tables Studs at 300 centres
Deflection Ratio: L/360 Deflection Ratio: L/360
Effective Length: 0.85 x L Effective Length: 0.5 x L (Mid-Span Noggins)

Unfactored Wind load (kN/m2) Unfactored Wind load (kN/m2)


Stud Section 0.6 0.8 1 1.2 1.4 1.6 1.8 2 Stud Section 0.6 0.8 1 1.2 1.4 1.6 1.8 2
C070050150 3.82 3.47 3.22 3.03 2.88 2.75 2.65 2.56 C070050150 3.82 3.47 3.22 3.03 2.88 2.75 2.65 2.56
C070070200 4.59 4.17 3.87 3.64 3.46 3.31 3.18 3.07 C070070200 4.59 4.17 3.87 3.64 3.46 3.31 3.18 3.07
C100050120 4.43 4.10 3.86 3.68 3.50 3.35 3.22 3.11 C100050120 4.65 4.22 3.92 3.69 3.50 3.35 3.22 3.11
C100060120 4.87 4.43 4.11 3.87 3.67 3.51 3.38 3.26 C100060120 4.87 4.43 4.11 3.87 3.67 3.51 3.38 3.26
C100070120 5.08 4.61 4.28 4.03 3.83 3.66 3.52 3.40 C100070120 5.08 4.61 4.28 4.03 3.83 3.66 3.52 3.40
C100070160 5.58 5.07 4.71 4.43 4.21 4.02 3.87 3.74 C100070160 5.58 5.07 4.71 4.43 4.21 4.02 3.87 3.74
C100070200 5.99 5.44 5.05 4.76 4.52 4.32 4.15 4.01 C100070200 5.99 5.44 5.05 4.76 4.52 4.32 4.15 4.01
C125050120 4.74 4.40 4.14 3.95 3.79 3.66 3.54 3.45 C125050120 5.51 5.00 4.65 4.37 4.15 3.97 3.82 3.69
C125060120 5.36 4.97 4.68 4.46 4.28 4.13 4.00 3.86 C125060120 5.77 5.24 4.86 4.58 4.35 4.16 4.00 3.86
C125070120 5.94 5.45 5.06 4.76 4.52 4.33 4.16 4.02 C125070120 6.00 5.45 5.06 4.76 4.52 4.33 4.16 4.02
C125070160 6.49 5.99 5.56 5.24 4.97 4.76 4.57 4.42 C125070160 6.60 5.99 5.56 5.24 4.97 4.76 4.57 4.42
C125070200 7.01 6.44 5.98 5.63 5.34 5.11 4.91 4.74 C125070200 7.09 6.44 5.98 5.63 5.34 5.11 4.91 4.74
C150050120 5.02 4.65 4.39 4.18 4.01 3.88 3.76 3.65 C150050120 6.34 5.76 5.35 5.03 4.78 4.57 4.40 4.25
C150060120 5.67 5.26 4.96 4.73 4.54 4.39 4.25 4.14 C150060120 6.63 6.02 5.59 5.26 5.00 4.78 4.59 4.44
C150070120 6.29 5.83 5.50 5.25 5.04 4.86 4.72 4.59 C150070120 6.89 6.26 5.81 5.46 5.19 4.97 4.77 4.61
C150070160 6.85 6.35 5.98 5.69 5.46 5.27 5.11 4.97 C150070160 7.57 6.88 6.39 6.01 5.71 5.46 5.25 5.07
C150070200 7.38 6.81 6.41 6.10 5.85 5.64 5.46 5.30 C150070200 8.14 7.40 6.87 6.46 6.14 5.87 5.64 5.45
C200050120 5.48 5.08 4.79 4.57 4.39 4.24 4.11 4.00 C200050120 7.06 6.55 6.18 5.89 5.66 5.46 5.30 5.15
C200060120 6.21 5.76 5.43 5.18 4.98 4.81 4.66 4.54 C200060120 8.00 7.43 6.98 6.57 6.24 5.97 5.74 5.54
C200070120 6.89 6.40 6.04 5.76 5.53 5.34 5.18 5.04 C200070120 8.58 7.80 7.24 6.81 6.47 6.19 5.95 5.74
C200070160 7.48 6.93 6.54 6.23 5.98 5.78 5.60 5.45 C200070160 9.44 8.58 7.96 7.49 7.12 6.81 6.55 6.32
C200070200 8.01 7.41 6.98 6.65 6.38 6.15 5.96 5.80 C200070200 10.16 9.23 8.57 8.06 7.66 7.32 7.04 6.80
C250070120 7.39 6.86 6.48 6.18 5.94 5.74 5.56 5.41 C250070120 9.55 8.87 8.37 7.98 7.66 7.36 7.08 6.84
C250070160 8.01 7.42 7.00 6.68 6.41 6.19 6.01 5.84 C250070160 10.31 9.56 9.02 8.60 8.26 7.98 7.73 7.52
C250070200 8.55 7.92 7.46 7.11 6.82 6.58 6.38 6.21 C250070200 10.96 10.16 9.58 9.13 8.77 8.46 8.20 7.98
C300070200 9.02 8.35 7.88 7.51 7.21 6.96 6.75 6.56 C300070200 11.58 10.74 10.13 9.66 9.28 8.96 8.69 8.45

When using these tables, please refer to notes in Section 2.7. Note: Spans highlighted in Bold and Italic may require non-standard stud/track end conditions please check separately.

12
SFS Span Tables Studs at 600 centres
Deflection Ratio: L/240 Deflection Ratio: L/240
Effective Length: 0.85 x L Effective Length: 0.5 x L (Mid-Span Noggins)

Unfactored Wind load (kN/m2) Unfactored Wind load (kN/m2)


Stud Section 0.6 0.8 1 1.2 1.4 1.6 1.8 2 Stud Section 0.6 0.8 1 1.2 1.4 1.6 1.8 2
C070050150 3.47 3.15 2.93 2.75 2.61 2.50 2.40 2.32 C070050150 3.47 3.15 2.93 2.75 2.61 2.50 2.40 2.32
C070070200 4.17 3.79 3.52 3.31 3.15 3.01 2.89 2.79 C070070200 4.17 3.79 3.52 3.31 3.15 3.01 2.89 2.79
C100050120 3.68 3.41 3.21 3.05 2.93 2.83 2.74 2.66 C100050120 4.22 3.84 3.56 3.35 3.18 3.04 2.93 2.83
C100060120 4.15 3.84 3.62 3.45 3.31 3.19 3.07 2.96 C100060120 4.43 4.02 3.74 3.51 3.34 3.19 3.07 2.96
C100070120 4.60 4.19 3.89 3.66 3.48 3.33 3.20 3.09 C100070120 4.61 4.19 3.89 3.66 3.48 3.33 3.20 3.09
C100070160 5.02 4.61 4.28 4.02 3.82 3.66 3.51 3.39 C100070160 5.07 4.61 4.28 4.02 3.82 3.66 3.52 3.39
C100070200 5.42 4.95 4.59 4.32 4.10 3.93 3.77 3.64 C100070200 5.44 4.95 4.59 4.32 4.11 3.93 3.78 3.64
C125050120 3.95 3.66 3.45 3.28 3.15 3.04 2.95 2.86 C125050120 5.00 4.55 4.22 3.97 3.77 3.61 3.47 3.35
C125060120 4.46 4.13 3.90 3.71 3.56 3.44 3.33 3.24 C125060120 5.24 4.76 4.42 4.16 3.95 3.78 3.63 3.51
C125070120 4.94 4.58 4.32 4.11 3.95 3.81 3.69 3.58 C125070120 5.45 4.95 4.60 4.33 4.11 3.93 3.78 3.65
C125070160 5.38 4.98 4.69 4.46 4.28 4.13 4.00 3.89 C125070160 5.99 5.44 5.05 4.76 4.52 4.32 4.16 4.01
C125070200 5.78 5.34 5.02 4.77 4.57 4.41 4.27 4.15 C125070200 6.44 5.85 5.43 5.11 4.86 4.64 4.47 4.31
C150050120 4.18 3.88 3.66 3.48 3.34 3.23 3.13 3.04 C150050120 5.37 4.98 4.69 4.46 4.28 4.12 3.99 3.86
C150060120 4.73 4.39 4.14 3.94 3.78 3.65 3.54 3.44 C150060120 6.02 5.47 5.08 4.78 4.54 4.34 4.17 4.03
C150070120 5.25 4.86 4.59 4.37 4.20 4.05 3.92 3.81 C150070120 6.26 5.68 5.28 4.97 4.72 4.51 4.34 4.19
C150070160 5.69 5.27 4.97 4.73 4.54 4.38 4.25 4.13 C150070160 6.88 6.25 5.80 5.46 5.19 4.96 4.77 4.61
C150070200 6.10 5.64 5.31 5.05 4.84 4.67 4.52 4.40 C150070200 7.40 6.72 6.24 5.87 5.58 5.33 5.13 4.95
C200050120 4.57 4.24 4.00 3.82 3.66 3.54 3.43 3.34 C200050120 5.89 5.46 5.15 4.91 4.71 4.54 4.40 4.28
C200060120 5.18 4.81 4.54 4.33 4.16 4.01 3.89 3.78 C200060120 6.68 6.19 5.83 5.56 5.33 5.14 4.98 4.83
C200070120 5.76 5.34 5.04 4.81 4.62 4.46 4.32 4.20 C200070120 7.42 6.87 6.47 6.16 5.88 5.62 5.41 5.22
C200070160 6.23 5.78 5.45 5.19 4.98 4.81 4.66 4.54 C200070160 8.01 7.42 6.99 6.66 6.39 6.16 5.95 5.74
C200070200 6.65 6.15 5.80 5.52 5.30 5.12 4.96 4.82 C200070200 8.51 7.88 7.43 7.07 6.78 6.54 6.34 6.16
C250070120 6.18 5.74 5.41 5.16 4.96 4.79 4.65 4.52 C250070120 7.98 7.40 6.97 6.64 6.37 6.15 5.95 5.78
C250070160 6.68 6.19 5.84 5.57 5.35 5.17 5.01 4.87 C250070160 8.60 7.98 7.52 7.17 6.88 6.64 6.43 6.25
C250070200 7.11 6.59 6.21 5.92 5.68 5.48 5.32 5.17 C250070200 9.13 8.46 7.98 7.60 7.30 7.04 6.82 6.63
C300070200 7.51 6.96 6.56 6.26 6.01 5.80 5.63 5.47 C300070200 9.66 8.96 8.45 8.05 7.73 7.46 7.23 7.04

When using these tables, please refer to notes in Section 2.7. Note: Spans highlighted in Bold and Italic may require non-standard stud/track end conditions please check separately.

13
SFS Span Tables Studs at 400 centres
Deflection Ratio: L/240 Deflection Ratio: L/240
Effective Length: 0.85 x L Effective Length: 0.5 x L (Mid-Span Noggins)

Unfactored Wind load (kN/m2) Unfactored Wind load (kN/m2)


Stud Section 0.6 0.8 1 1.2 1.4 1.6 1.8 2 Stud Section 0.6 0.8 1 1.2 1.4 1.6 1.8 2

C070050150 3.97 3.61 3.35 3.15 2.99 2.86 2.75 2.66 C070050150 3.97 3.61 3.35 3.15 2.99 2.86 2.75 2.66
C070070200 4.77 4.34 4.03 3.79 3.60 3.44 3.31 3.20 C070070200 4.77 4.34 4.03 3.79 3.60 3.44 3.31 3.20
C100050120 4.10 3.80 3.58 3.41 3.27 3.15 3.05 2.97 C100050120 4.83 4.39 4.08 3.83 3.64 3.48 3.35 3.23
C100060120 4.63 4.28 4.04 3.84 3.69 3.56 3.45 3.35 C100060120 5.07 4.60 4.27 4.02 3.82 3.65 3.51 3.39
C100070120 5.12 4.74 4.45 4.19 3.98 3.81 3.66 3.54 C100070120 5.28 4.80 4.45 4.19 3.98 3.81 3.66 3.54
C100070160 5.61 5.18 4.88 4.61 4.37 4.18 4.02 3.88 C100070160 5.80 5.27 4.89 4.61 4.37 4.18 4.02 3.88
C100070200 6.08 5.60 5.26 4.95 4.70 4.49 4.32 4.17 C100070200 6.23 5.66 5.26 4.95 4.70 4.49 4.32 4.17
C125050120 4.40 4.07 3.84 3.66 3.51 3.39 3.28 3.19 C125050120 5.64 5.20 4.83 4.55 4.32 4.13 3.97 3.83
C125060120 4.97 4.60 4.34 4.13 3.97 3.83 3.71 3.61 C125060120 6.00 5.45 5.06 4.76 4.52 4.32 4.16 4.01
C125070120 5.50 5.10 4.81 4.58 4.40 4.24 4.11 4.00 C125070120 6.24 5.67 5.26 4.95 4.70 4.50 4.33 4.18
C125070160 6.00 5.55 5.23 4.98 4.77 4.61 4.46 4.34 C125070160 6.86 6.23 5.79 5.44 5.17 4.95 4.76 4.59
C125070200 6.47 5.97 5.61 5.34 5.11 4.93 4.77 4.64 C125070200 7.37 6.70 6.22 5.85 5.56 5.32 5.11 4.93
C150050120 4.65 4.31 4.07 3.88 3.72 3.59 3.48 3.39 C150050120 5.98 5.54 5.22 4.98 4.77 4.61 4.46 4.33
C150060120 5.26 4.88 4.60 4.39 4.21 4.07 3.94 3.83 C150060120 6.77 6.26 5.81 5.47 5.20 4.97 4.78 4.61
C150070120 5.83 5.41 5.10 4.86 4.67 4.51 4.37 4.25 C150070120 7.16 6.51 6.04 5.68 5.40 5.16 4.96 4.79
C150070160 6.35 5.88 5.54 5.27 5.06 4.88 4.73 4.60 C150070160 7.87 7.15 6.64 6.25 5.94 5.68 5.46 5.27
C150070200 6.81 6.30 5.92 5.64 5.41 5.21 5.05 4.91 C150070200 8.46 7.69 7.14 6.72 6.38 6.10 5.87 5.67
C200050120 5.08 4.71 4.45 4.24 4.07 3.94 3.82 3.71 C200050120 6.55 6.08 5.73 5.46 5.24 5.06 4.91 4.77
C200060120 5.76 5.34 5.04 4.81 4.62 4.46 4.33 4.21 C200060120 7.43 6.89 6.50 6.19 5.94 5.73 5.56 5.40
C200070120 6.40 5.94 5.60 5.34 5.13 4.96 4.81 4.67 C200070120 8.25 7.65 7.21 6.87 6.60 6.36 6.16 5.97
C200070160 6.93 6.43 6.06 5.78 5.55 5.35 5.19 5.05 C200070160 8.91 8.26 7.79 7.42 7.12 6.87 6.66 6.47
C200070200 7.41 6.86 6.46 6.15 5.91 5.70 5.52 5.37 C200070200 9.48 8.78 8.28 7.88 7.57 7.30 7.07 6.87
C250070120 6.86 6.37 6.02 5.74 5.51 5.32 5.16 5.02 C250070120 8.87 8.23 7.76 7.40 7.10 6.86 6.64 6.46
C250070160 7.43 6.89 6.50 6.19 5.95 5.75 5.57 5.42 C250070160 9.57 8.87 8.37 7.98 7.66 7.39 7.17 6.97
C250070200 7.92 7.33 6.91 6.59 6.32 6.10 5.92 5.76 C250070200 10.16 9.42 8.88 8.46 8.12 7.84 7.60 7.39
C300070200 8.35 7.74 7.30 6.96 6.68 6.45 6.26 6.09 C300070200 10.74 9.96 9.40 8.96 8.60 8.31 8.05 7.83

When using these tables, please refer to notes in Section 2.7. Note: Spans highlighted in Bold and Italic may require non-standard stud/track end conditions please check separately.

14
SFS Span Tables Studs at 300 centres
Deflection Ratio: L/240 Deflection Ratio: L/240
Effective Length: 0.85 x L Effective Length: 0.5 x L (Mid-Span Noggins)

Unfactored Wind load (kN/m2) Unfactored Wind load (kN/m2)


Stud Section 0.6 0.8 1 1.2 1.4 1.6 1.8 2 Stud Section 0.6 0.8 1 1.2 1.4 1.6 1.8 2
C070050150 4.32 3.97 3.69 3.47 3.29 3.15 3.03 2.92 C070050150 4.37 3.97 3.69 3.47 3.29 3.15 3.03 2.92
C070070200 5.26 4.78 4.43 4.17 3.96 3.79 3.64 3.52 C070070200 5.26 4.78 4.43 4.17 3.96 3.79 3.64 3.52
C100050120 4.43 4.10 3.86 3.68 3.53 3.41 3.30 3.21 C100050120 5.32 4.83 4.49 4.22 4.01 3.84 3.69 3.56
C100060120 5.00 4.63 4.36 4.15 3.98 3.84 3.72 3.62 C100060120 5.58 5.07 4.71 4.43 4.21 4.02 3.87 3.73
C100070120 5.53 5.12 4.83 4.60 4.38 4.19 4.03 3.89 C100070120 5.81 5.28 4.90 4.61 4.38 4.19 4.03 3.89
C100070160 6.08 5.61 5.28 5.02 4.81 4.61 4.43 4.28 C100070160 6.39 5.80 5.39 5.07 4.82 4.61 4.43 4.28
C100070200 6.60 6.08 5.70 5.42 5.17 4.95 4.76 4.59 C100070200 6.86 6.23 5.79 5.44 5.17 4.95 4.76 4.59
C125050120 4.74 4.40 4.14 3.95 3.79 3.66 3.54 3.45 C125050120 6.09 5.64 5.31 5.00 4.75 4.55 4.37 4.22
C125060120 5.36 4.97 4.68 4.46 4.28 4.13 4.01 3.90 C125060120 6.60 6.00 5.57 5.24 4.98 4.76 4.58 4.42
C125070120 5.94 5.50 5.19 4.94 4.75 4.58 4.44 4.32 C125070120 6.87 6.24 5.79 5.45 5.18 4.95 4.76 4.60
C125070160 6.49 6.00 5.65 5.38 5.16 4.98 4.82 4.69 C125070160 7.55 6.86 6.37 5.99 5.69 5.44 5.24 5.05
C125070200 7.01 6.47 6.08 5.78 5.54 5.34 5.16 5.02 C125070200 8.11 7.37 6.84 6.44 6.12 5.85 5.63 5.43
C150050120 5.02 4.65 4.39 4.18 4.01 3.88 3.76 3.65 C150050120 6.45 5.98 5.64 5.37 5.16 4.98 4.82 4.69
C150060120 5.67 5.26 4.96 4.73 4.54 4.39 4.25 4.14 C150060120 7.30 6.77 6.38 6.02 5.72 5.47 5.26 5.08
C150070120 6.29 5.83 5.50 5.25 5.04 4.86 4.72 4.59 C150070120 7.88 7.16 6.65 6.26 5.94 5.68 5.46 5.28
C150070160 6.85 6.35 5.98 5.69 5.46 5.27 5.11 4.97 C150070160 8.67 7.87 7.31 6.88 6.53 6.25 6.01 5.80
C150070200 7.38 6.81 6.41 6.10 5.85 5.64 5.46 5.30 C150070200 9.32 8.47 7.86 7.40 7.02 6.72 6.46 6.24
C200050120 5.48 5.08 4.79 4.57 4.39 4.24 4.11 4.00 C200050120 7.06 6.55 6.18 5.89 5.66 5.46 5.30 5.15
C200060120 6.21 5.76 5.43 5.18 4.98 4.81 4.66 4.54 C200060120 8.00 7.43 7.01 6.68 6.41 6.19 6.00 5.83
C200070120 6.89 6.40 6.04 5.76 5.53 5.34 5.18 5.04 C200070120 8.89 8.25 7.78 7.42 7.12 6.87 6.66 6.47
C200070160 7.48 6.93 6.54 6.23 5.98 5.78 5.60 5.45 C200070160 9.61 8.91 8.40 8.01 7.69 7.42 7.19 6.99
C200070200 8.01 7.41 6.98 6.65 6.38 6.15 5.96 5.80 C200070200 10.24 9.48 8.94 8.51 8.17 7.88 7.64 7.43
C250070120 7.39 6.86 6.48 6.18 5.94 5.74 5.56 5.41 C250070120 9.55 8.87 8.37 7.98 7.66 7.40 7.17 6.97
C250070160 8.01 7.42 7.00 6.68 6.41 6.19 6.01 5.84 C250070160 10.31 9.56 9.02 8.60 8.26 7.98 7.73 7.52
C250070200 8.55 7.92 7.46 7.11 6.82 6.58 6.38 6.21 C250070200 10.96 10.16 9.58 9.13 8.76 8.46 8.20 7.98
C300070200 9.02 8.35 7.88 7.51 7.21 6.96 6.75 6.56 C300070200 11.58 10.74 10.13 9.66 9.28 8.96 8.68 8.45

When using these tables, please refer to notes in Section 2.7. Note: Spans highlighted in Bold and Italic may require non-standard stud/track end conditions please check separately.

15
3 SFS STANDARD FIXINGS
3.1 Recommended Fixings
Kingspan Steel Building Solutions do not sell fixings associated with SFS. Set out below are standard SFS fixings from a variety of manufacturers. All
fixings stated are general recommendations only. All connections from the SFS to any interfacing structure or material must be checked for suitability and
design with Kingspan Steel Building Solutions and the third party supplier prior to construction. Installers may also wish to use other fixings this should be
communicated to Kingspan at the start of the project (prior to design commencing) such that they can be checked for suitability and incorporated into the
design.

Note: Kingspan do not recommend the use of PH3 fixings for flush cold rolled to cold rolled connections

Application Supplier Product Code Description Tools Picture


Pancake head
CFC26 5.5 x 32mm SDS Gun
ITW-SPIT
SFS to SFS Connections (Eurocode 921166) Self Drilling, Coarse 2PSD
Flush finish threaded, Self tapping TEK
1mm up to 4.0mm fixing Waferhead
thickness S-MD 03ZW 5.5 x 25 5.5 x 25mm SDS Gun
Hilti
408762 Self Drilling, Coarse Phillips No.2
threaded, Self tapping TEK

Hex head 5.5 x 25mm


TC25 SDS Gun
ITW-SPIT Self Drilling, Coarse
(Eurocode 920028) 5/16th AF Hex
threaded, Self tapping TEK

Hex head 5.5 x 25mm


S-MD 03Z 5.5x25 SDS Gun
Hilti Self Drilling, Coarse
SFS to SFS Connections 413417 8mm Hex
threaded, Self tapping TEK
Non flush finish
1mm up to 4.0mm fixing
thickness Hex head 5.5 x 25mm
SDS Gun
Ejot LS 5.5 x 25 Self Drilling, Coarse
8mm Hex
threaded, Self tapping TEK

Hex head 5.5 x 25mm


SDS Gun
Evolution TSHW5.5-25-3 Self Drilling, Coarse
5/16th AF Hex
threaded, Self tapping TEK

16
Application Supplier Product Code Description Tools Picture
Pancake head
CFL32 5.5 x 32mm Low Profile SDS Gun
ITW-SPIT
(Eurocode 921260) TEK, Self Drilling, Fine Phillips No.2
threaded, Self tapping

SFS to Hot Rolled Steel Wafer Head


Flush finish S-MD 05ZW 5.5x40 5.5 x 40mm Low Profile SDS Gun
Hilti
4 to 12.5mm fixing thickness 408763 TEK, Self Drilling, Fine Phillips No.3
threaded, Self tapping
Flat pan head
5.5 x 38mm SDS Gun
Ejot HSCF 5.5x38
Self Drilling, Coarse Phillips No.3
threaded, Self tapping TEK
Hex head screw
TL32 5.5 x 32mm TEK SDS Gun
ITW-SPIT
(Eurocode 921202) Self Drilling, Fine threaded, 5/16th AF Hex
Self tapping
Hex head screw
S-MD05Z 5.5 x 40 5.5 x 40mm TEK SDS Gun
Hilti
2054483 Self Drilling, Fine threaded, 8mm Hex
SFS to Hot Rolled Steel Self tapping
Non flush finish
3.0mm steel to 12.5mm HRS Hex head screw
5.5 x 38mm TEK SDS Gun
Ejot HS 5.5 x 38
Self Drilling, Fine threaded, 8mm Hex
Self tapping
Hex head screw
5.5 x 38mm TEK SDS Gun
Evolution TSHW5.5-38-5(SI)II
Self Drilling, Fine threaded, 5/16" Hex
Self tapping

ITW-SPIT SC9-20 Powder actuated nail fixing Spitfire P370

SFS to Hot Rolled Steel X-U 16 MX DX460MX


Connections Hilti Powder actuated nail fixing
2043797
SFS to 20mm HRS

Hex head screw


6.3 x 65mm TEK SDS Gun
Fixfast DF25 6.3 x 65
Self Drilling, Fine threaded, 8mm Hex
Self tapping

17
Application Supplier Product Code Description Tools Picture
SDS Gun
Hex head anchor 8mm Hex
4H32
ITW-SPIT 6 x 32mm SDS Drill
(Eurocode 921502)
6mm masonry
bit

Impact Driver
HUS 6x45 Hex head anchor
Hilti Torx 40
2065502 6 x 45mm
SDS Drill 6mm
SFS to Concrete
Connections SDS Gun
3.0mm steel to concrete 8mm Hex
Hex head anchor
Ejot 4H 6.3x32 SDS Drill
6.3 x 32mm
CDR 4L (Ejot
ref)
SDS Gun
5/16" Hexagonal
Hex head anchor
Evolution MSHH6.3-32-516 SDS Drill
6.3 x 32mm
5mm masonry
bit

G8.8 bolts with locking nut


Bolted connection G8.8 Bolts SDS Drill
Bracket to Hot Rolled Steel and washers.
Connections
5 to 8mm steel brackets to
>6mm HRS
Spider Bolt NSL-1998 Blind bolt SDS Drill

Through bolt
SDS Gun
ITW-SPIT TRIGA Z V6 10/20 Torque controlled expanding
SDS Drill
anchor

Stud anchor
SDS Gun
ITW-SPIT TRIGA Z E6 10/20 Torque controlled expanding
SDS Drill
anchor
Bracket to Concrete
Steel brackets to Concrete
Tapcon LDT M10x60 SDS Gun
ITW-SPIT Large diameter screw anchor
(Typical) SDS Drill

HSC-A M10 x 40mm safety SDS Gun


Hilti HSC-A M10 x 40mm
anchors SDS Drill

18
Application Supplier Product Code Description Tools Picture
S-WD 13C 4.8 x 38
4.8 x 38mm wafer head wing SDS Gun
Hilti S-WD 13C 5.5 x 65
Sheathing Board / Timber to tip screw Phillips No.2
283636, 283638
SFS
(Max. 47mm board to max.
steel thickness 3.0mm) WDLS 4.8 x 38 4.8 x 38mm wafer head wing SDS Gun
Ejot
WDLS 5.5 x 50 to 127 tip screw Phillips No.2

1.2 to 1.5mm channel to SFS


S-CD 53S 5.5 x 86 to SDS Gun
Hilti through varying insulation
156 8mm Hex
thickness
Brick tie channels to SFS
JT3-6-5.5 x 70 S16 1.2 to 1.5mm channel to max
SDS Gun
Ejot JT3-D-6H 5.5/6.3x 87 1.6mm steel through varying
8mm Hex
to147 S16 insulation thickness

Rigid phenolic insulation JT3-6-5.5 x L S16 with Varying insulation thickness SDS Gun
Ejot
board to SFS SBV 90 washer up to 100mm to 4.0mm steel 8mm Hex

Black self-drill drywall screw


S-DD01B 3.5 x 25 to SDS Gun
Hilti Board to max. 2.25mm SFS
55 Phillips No.2
sections

BZP self-drill drywall screw


S-DD01Z 3.5 x 25 to SDS Gun
Hilti Board to max. 2.25mm SFS
65 Phillips No.2
Internal Lining: sections
Plasterboard / Chipboard /
Ply / OSB to SFS
Board to max. 3mm SFS SDS Gun
Ejot WDLS 5.5 x 50 to 127
sections Phillips No.3

Board to 4mm SFS sections


SDS Gun
Ejot WDHS5.5 x 65 to 119 and hot rolled steel up to
Phillips No.3
12mm gauge

19
4 INFILL SFS

Figure 2 - Typical Infill SFS Bay

4.1 Design Principles


4.1.1 General Stud Design & Construction
Studs are generally provided vertically at centres of 600mm,though may be provided at 400mm or 300mm as
determined by structural calculation. These centres are determined by interfacing board dimensions of
2400x1200mm (external or internal board). The frames are constructed using a head and base track into which
vertical studs are placed. Deflection is typically accommodated at the head connection of the vertical studs to
the head track. A corresponding deflection gap in the cladding is normally also needed.

4.1.2 Structural Openings


The forming of structural openings is easily managed with the Infill SFS System. Constructions of lintels, cills
and jambs must always be confirmed by Kingspan Steel Building Solutions engineers. Details given in Section 6
show construction method only and do not form a specification.

4.1.3 Splicing of Sections


Infill sections should be ordered to length or to be cut down on site. Under no circumstances should they be
spliced together.

4.1.4 Deflection Head Details


Deflection zones must be kept clear of all fixings and materials that may compromise the movement joint
provided at the head of the SFS. Kingspan Steel Building Solutions Technical will defer to Type 4 deflection
method in all instances where a fixing can be practically made on both sides of the SFS wall. Each method has
implications on design and they should not be interchanged on site without prior agreement with Kingspan Steel
Building Solutions. Further details on all methods are available in the standard details.

Type 1 Deflection Head Clip (Detail A14)


The deflection head clip system works using a shaped bracket that fits inside the legs of the track that holds
the stud in place, providing clearance for the track to move without fouling on the top of the stud or on any
fixings. This method only applies to the 70, 100, 150, 200, 250 and 300mm ranges.
Type 2 Block and Bracing (Detail A15)
There may be areas of the build where it is not possible to access both flanges of the head track. Below the
obstruction, the studs will receive flat strap fixed on either side with a noggin section tightly fitted and fixed
between every third stud and at both ends of each bay. When the noggin is fitted the studs will remain
solidly in place, unable to twist due to the blocking section.

20
Type 3 Head Track Blocking (Detail A16)
An installer may choose a third method of creating an allowance for deflection, by placing blocking sections
of stud within the top track, tightly fitting between every stud. This will prevent the studs from racking or
twisting and allow the track to move freely over the studs.
Type 4 Slotted Stud (Detail A21)
The Slotted Stud system works using a centrally positioned pre-punched slot in the flange of the C profile.
The stud is secured using fixings installed through both flanges of the head track through the slots in the
stud. This allows for relative deflection of the head track whilst still providing restraint for the studs.

When using the slotted stud, the installer should be aware of the following:
When placing orders for slotted studs, the order must clearly state that slotted studs are required. This is the
responsibility of the installer.
Kingspan have a minimum rolling length of 600mm for each section. Therefore, cripple studs beneath this
length do not require slots and can be fixed to the lintel only as shown in Figure 3 below:

Figure 3 Slotted stud cripple studs for spans below 600mm

4.1.5 Mid Span Restraint (Detail 0)


Mid span restraint may be specified by Kingspan Steel Building Solutions engineers in instances of high vertical
spans or of high load. Their purpose is to restrain the studs from twisting.

4.1.6 Cladding Treatments & Boarding


The performance of the SFS when subject to loads from cladding treatments is taken into account by Kingspan
Steel Building Solutions engineers. Specialist cladding treatments may require different structural schemes
based on the loading arrangements or system requirements of these systems. Unless otherwise instructed,
Kingspan Steel Building Solutions engineers will assume that all loads are uniformly distributed across a given
panel.

4.1.6.1 Masonry cladding


SFS can provide lateral support to masonry cladding (i.e. restraint from wind loads) but it must never be used
to support brick or other such heavy-weight cladding. It is the responsibility of the primary structural
engineer on the project to ensure that adequate support for such cladding types is provided.
rd
4.1.7 2/3 Minimum Bearing
rd
As a general rule, the head and base tracks of any SFS frame must be supported by a minimum of 2/3 the
width of the track by a primary structural element (concrete or hot rolled steel). In instances at the head of a
frame where this bearing is not available, Z bars may be used as shown in Detail Error! Reference source
ot found. and B.06s. At the base of a frame, Detail 0 may be used. All conditions must be checked with a
Kingspan Steel Building Solutions engineer prior to construction.

21
4.1.8 Service Holes
Holes may be required in SFS members to allow cabling or pipework to pass within the wall zone. SCI
Publication 301 Light Steel Framing in Residential Construction (Section 9) gives an approximate guide to the
maximum sizes and spacing of service penetrations in light gauge steel sections without compromising the
structural integrity. The following rules should be followed when drilling holes within SFS sections.

Figure 4 - Service holes

A Depth of member - - -

B Distance from edge of hole to end of member B 1.5 * A

C Clear distance between holes C A

D Diameter of circular holes D 0.6 * A

E Width of elongated service hole / slot E 3*F

F Depth of elongated service hole / slot F 0.4 * A

No holes outside of these rules should be created in SFS members without the prior agreement of Kingspan
Steel Building Solutions technical team.

4.1.9 Curved Walling


SFS can readily accommodate curved walling using a variety of construction details as outlined later in this
document. It must be noted though that SFS cannot form curved windows without additional curved hot rolled
restraint/support. SFS can be facetted around the window but will usually require restraint posts at each facet
location. For further guidance, please contact Kingspan Steel Building Solutions technical team.

22
4.1.10 Braced Bays
Where structural bracing fouls the zone of the SFS, alternative detailing must be provided. There are several
ways to accomplish this, each of which requires coordination with the design engineer and fabricator:
Use of SHS or RHS bracing instead of flats allows SFS to be fitted above and below.
Flat strap bracing can be detailed offset to the external or internal face, allowing SFS to span unimpeded in
the remaining zone. This must be confirmed with the engineer/fabricator as it will result in eccentric loads
applied to the columns.
If neither of the above are possible, twin 70mm systems may be able to span either side of the bracing and
be tied together at regular vertical centres if required by design.

Figure 5 - SHS Bracing Figure 6 - Off-set bracing Figure 7 - Twin system around bracing

For specific guidance, please contact Kingspan Steel Building Solutions.

4.1.11 Parapets and Downstands


Parapets and downstands can be formed in SFS but designers should be aware that SFS is a vertically
spanning product which requires restraint at head and base. This can be by use of hot rolled restraint posts at
regular centres with an SFS section spanning horizontally between them (as details 0 & 0), by use of buttressing
walls or by use of diagonal propping/bracing back into the structure.

4.1.12 Ribbon Windows


Ribbon windows and large punch windows may be formed in SFS in a variety of ways:
The windows may include blanking panels, behind which SFS can span full height to break up the opening
into manageable widths. The maximum centres for such panels will be project specific and Kingspan Steel
Building Solutions should be consulted for guidance on each job.
The project engineer may provide wind posts at certain centres to break up the spans of large lintels and
cills into manageable widths. For guidance on post centres, please contact Kingspan Steel Building
Solutions.
The SFS section depth (i.e. overall wall depth) may be increased to allow it to span further without
additional restraints. In this way, it may be possible to span SFS between primary structural columns.
The openings may be framed out in hot rolled steel by others.

4.1.13 Brise Soleil


It is possible for SFS to support a brise soleil in certain situations. This will depend upon the spans and applied
loads but the following guidance will need to be observed:
The brise soleil bracketry must be fixed back to the webs of the studs designed to support it not the
flange.
Kingspan will require a full schedule of the loads applied by the brise soleil in order to design the SFS to
support it. Generally, this will include snow, wind and dead loads.
The SFS will require strengthening in order to support the screens and none should be installed without
prior agreement with Kingspan Steel Building Solutions technical team.
Potential cold bridging issues will need to be assessed by the architect / design team.

23
4.1.14 Kingposts
The KingPOST is a wind moment post designed and supplied by Kingspan Steel Building Solutions.

The KingPOST is an alternative for bespoke hot rolled steel posts and is used to provide restraint to the SFS
system on applications such as large spanning windows or parapets. It offers a standard off the shelf solution
that can be used to form a range of cantilevers. The base is a standard assembly to which light gauge steel
studs can be fixed to form the final arrangement.

Further details on Kingposts can be found on Kingspan Technical Application Document: Kingpost Installation
(TAD 00057) and standard details C.18a and C.19a

4.1.15 Oversail Cleats

Kingspan Steel Building Solutions have developed a range of standard oversail cleats as an alternative for
bespoke lateral or dead load cleats. The cleats can be used to fix the SFS studs back to the primary structure at
intermediate positions to provide lateral and dead restraint. It offers a standard off the shelf solution that can be
ordered in a range of depths and leg lengths to suit.

The SFS Oversail cleats will be designed and supplied by Kingspan Steel Building Solutions.

The SFS oversail cleats are suitable for general studs and jamb studs, but bespoke cleats may be required for
non-standard applications.

Cleat Ref; KWC9524 Cleat Ref; KWC14028 Cleat Ref; KWC14040 Cleat Ref;

Further details on Kingspan Oversail Cleats can be found on Kingspan Technical Application Document:
Kingpost Installation (TAD 00058) and standard details.

24
5 OVERSAIL SFS

Figure 8 - Typical Oversail Bay

5.1 Design Principles


5.1.1 General Stud Design & Construction
Studs are generally provided vertically at centres of 600mm, 400mm or 300mm. These centres are
determined by interfacing board dimensions of 2400x1200mm (external or internal board). The SFS is set
outside the line of the primary structure and fixed back to steel beams and/or concrete slabs using
specifically designed brackets. Due to the varying nature of setting out, all brackets are designed on a
project specific basis. Brackets or ledger angles may require fitting to the slab edge onto which either
horizontal track or vertical studs can be fitted. Each stud requires individually setting out by design to
ascertain the right position for the support brackets. This construction method is limited as to the amount of
stories it can form before being dead load fixed back to the slab. For project specific guidance, please
contact Kingspan Steel Building Solutions.

5.1.2 Deflection Conditions


The provision for deflection within an oversail system is within the bracket fixed to the studs. The face of the
bracket that fits to the stud will be slotted and the face of the bracket that goes to the substrate will be hard
fixed. This will allow the structure to deflect independently of the SFS.

25
5.1.3 Splicing of Sections
Studs should be spliced into manageable lengths to facilitate safe site installation and to guarantee adequate
structural performance. These splices are individually designed to ensure that they are strong enough for
each application but will generally be just above restraint points. No splices should be added where not
indicated by the design. If additional cuts are required in order to safely install the system, please contact
Kingspan Steel Building Solutions prior to ordering the steel.

5.1.4 Structural Openings


Structural openings are formed in the same manner as the Infill method. However, due to increased loading
conditions at jambs, lintels and cills, the support bracketry to these elements may require heavier gauges
and increased fixing capacities.

Where openings do not align floor on floor, it may be impractical to use traditional oversail SFS. In these
instances, single storey overfills may be formed outside the line of the building using bespoke bracketry as
shown in detail 0.

5.1.5 Mid Span Restraint (Detail 0)


Mid span restraint is often used in Oversail faades to help stiffen the panel construction. The use of mid
span restraints will be determined under structural calculation and shown on the Kingspan Steel Building
Solutions elevation drawings. The specification and setting out of these noggins will be given in Kingspan
Steel Building Solutions drawings.

5.1.6 Cladding Treatments & Boarding (Detail E.01 & E.02)


Please refer to guidance in section 4.1.

5.1.7 Service Holes


Please refer to guidance in section 4.1.

5.1.8 Curved Walling


Please refer to guidance in section 4.1.

5.1.9 Braced Bays


Please refer to guidance in section 4.1.

5.1.10 Parapets and Downstands


In many instances, parapets and downstands are more easily formable in an oversail system as the studs
can be cantilevered from the floor above/below. This depends upon the spans and loads involved and
should be referred to Kingspan Steel Building Solutions for specific guidance.

5.1.11 Ribbon Windows


Please refer to guidance in section 4.1.

5.1.12 Brise Soleil


Please refer to guidance in section 4.1.

5.1.13 Fixings
The correct and adequate fixing of brackets to the primary structure must be specified by Kingspan Steel
Building Solutions engineers. Generally, bracket fixing to concrete take the form of either mechanical or resin
anchors and fixings to hot rolled steel will be grade 8.8 structural bolts.

26
6 STANDARD DETAILS
6.1 A Series Basic Connections
Rev.
A.01 Head Track to Concrete Connection Straight SD04
A.02 Head Track to Steel Connection Straight SD03
A.03 U Base Track to Concrete Connection Straight SD03
A.04 U Base Track to Steel Connection Straight SD03
A.05s Head Track to Concrete Connection Curved Option 1 (Slotted Stud) SD05
A.06s Head Track to Concrete Using Slotted Stud Connection Curved Option 2 SD04
A.07s Head Track to Steel Using Slotted Stud Connection Curved Option 1 SD04
A.08s Head Track to Steel Using Slotted Stud Connection Curved Option 2 SD04
A.09 Base Track to Concrete Connection Curved Option 1 SD03
A.10 Base Track to Concrete Connection Curved Option 2 SD03
A.11 Base Track to Steel Connection Curved Option 1 SD03
A.12 Base Track to Steel Connection Curved Option 2 SD03
A.13 Stud to Base Track Connection SD03
A.14 Stud to Head Track Using DHB Type 1 Head Clip SD03
A.15 Stud to Head Track Type 2 Block & Brace SD03
A.16 Stud to Head Track Type 3 Head Track Blocking Connection SD03
A.17 Stud Back-to-Back Construction SD03
A.18 Stud to Concrete Column SD03
A.19 Stud to Steel Column Connection SD03
A.20 Tracks Joint Fixing SD05
A.21 Slotted Stud to Head Track Type 4 Slotted Stud SD03
A.22 Flat Strap Bracing Detail Connection SD05
A.23 Vertical Stud to Steel Column Connection with welded plates SD03
A.24 Vertical Stud to Steel Column Connection SD03
A.25 Head Track Fixings at PFC Parapets SD01

These details are shown on the following pages.

27
ref note

A HEAD TRACK FIXED TO CONCRETE USING


FIXINGS AS SPECIFIED ON KPS DRAWINGS
B MINIMUM 32 BEARING ON STRUCTURE MUST
BE OBSERVED. IF DIFFERENT CONTACT KPS

IMPORTANT - FIXING EDGE DISTANCES MUST BE


OBSERVED AT ALL TIMES - REFER TO SPECIFIC
DRAWING NOTES AND FIXING DATASHEETS

REFER TO DETAIL A.21 FOR SLOTTED STUD DETAILS

SD04 REVIEW/UPDATE 19.09.14 KPS

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

A
STANDARD DETAIL

B Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: INFILL FRAMING


U HEAD TRACK TO CONCRETE
CONNECTION - STRAIGHT
date 16.12.09 drg by KPS
scale NTS sheet A4
detail ref A.01 rev SD04
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

A HEAD TRACK FIXED TO STEEL USING


FIXINGS AS SPECIFIED ON KPS DRAWINGS
B MINIMUM 32 BEARING ON STRUCTURE MUST
BE OBSERVED. IF DIFFERENT CONTACT KPS

IMPORTANT - FIXING EDGE DISTANCES MUST BE


OBSERVED AT ALL TIMES - REFER TO SPECIFIC
DRAWING NOTES AND FIXING DATASHEETS

REFER TO DETAIL A.21 FOR SLOTTED STUD DETAILS

SD04 REVIEW/UPDATE 19.09.14 KPS

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

A
STANDARD DETAIL

Steel Building
B Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: INFILL FRAMING


U HEAD TRACK STEEL
CONNECTION - STRAIGHT
date 16.12.09 drg by KPS
scale NTS sheet A4
detail ref A.02 rev SD04
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

A BASE TRACK FIXED TO CONCRETE USING


FIXINGS AS SPECIFIED ON KPS DRAWINGS

B MINIMUM 32 BEARING ON STRUCTURE MUST


BE OBSERVED. IF DIFFERENT CONTACT KPS

IMPORTANT - FIXING EDGE DISTANCES MUST BE


OBSERVED AT ALL TIMES - REFER TO SPECIFIC
DRAWING NOTES AND FIXING DATASHEETS

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
A Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: INFILL FRAMING


U BASE TRACK TO CONCRETE
CONNECTION - STRAIGHT
B date 16.12.09 drg by KPS
scale NTS sheet A4
detail ref A.03 rev SD03
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

A BASE TRACK FIXED TO STEEL USING


FIXINGS AS SPECIFIED ON KPS DRAWINGS

B MINIMUM 32 BEARING ON STRUCTURE MUST


BE OBSERVED. IF DIFFERENT CONTACT KPS

IMPORTANT - FIXING EDGE DISTANCES MUST BE


OBSERVED AT ALL TIMES - REFER TO SPECIFIC
DRAWING NOTES AND FIXING DATASHEETS

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

B Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: INFILL FRAMING


U BASE TRACK TO STEEL
CONNECTION - STRAIGHT
date 16.12.09 drg by KPS
scale NTS sheet A4
detail ref A.04 rev SD03
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

A HEAD TRACK FIXED TO STRUCTURE USING


FIXINGS AS SPECIFIED ON KPS DRAWINGS
B 1 FIXING REQUIRED AT TRACK JOINTS
50mm FROM BOTH TRACK ENDS

IMPORTANT - FIXING EDGE DISTANCES MUST BE


OBSERVED AT ALL TIMES - REFER TO SPECIFIC
A DRAWING NOTES AND FIXING DATASHEETS

MINIMUM 32 BEARING ON STRUCTURE AT ALL TIMES

TRACKS MUST NOT BE CUT AND FACETED ABOVE


OPENINGS WITHOUT KPS APPROVAL - CURVED
LINTELS AND CILLS CANNOT BE FORMED WITHOUT
ADDITIONAL RESTRAINT.

REFER TO DETAIL A.21 FOR SLOTTED STUD DETAILS

SD05 REVIEW/UPDATE 19.09.14 KPS

SD04 REVIEW/UPDATE 23.10.12 KPS

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

B title: INFILL FRAMING


HEAD TRACK CONC - SLOTTED STUDS
CONNECTION - CURVED - OPTION 1
date 16.12.09 drg by KPS
scale NTS sheet A4
detail ref A.05S rev SD05
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

A HEAD TRACK FIXED TO STRUCTURE USING


FIXINGS AS SPECIFIED ON KPS DRAWINGS
WITH A MINIMUM OF 1 FIXING REQUIRED
AT TRACK JOINTS 50mm FROM BOTH
TRACK ENDS.

IMPORTANT - FIXING EDGE DISTANCES MUST BE


OBSERVED AT ALL TIMES - REFER TO SPECIFIC
DRAWING NOTES AND FIXING DATASHEETS

MINIMUM 32 BEARING ON STRUCTURE AT ALL


TIMES

TRACKS MUST NOT BE CUT AND CURVED ABOVE


OPENINGS WITHOUT KPS APPROVAL - CURVED
LINTELS AND CILLS CANNOT BE FORMED
WITHOUT ADDITIONAL RESTRAINT.

REFER TO DETAIL A.21 FOR SLOTTED STUD


DETAILS

SD04 REVIEW/UPDATE 19.09.14 KPS

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

A
title: INFILL FRAMING
HEAD TRACK CONC. USING SLOTTED
STUD CONNECTION - STRAIGHT - OPTION 2
date 16.12.09 drg by KPS
scale NTS sheet A4
detail ref A.06S rev SD04
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

A HEAD TRACK FIXED TO STRUCTURE USING


FIXINGS AS SPECIFIED ON KPS DRAWINGS
B 1 FIXING REQUIRED AT TRACK JOINTS
50mm FROM BOTH TRACK ENDS.

IMPORTANT - FIXING EDGE DISTANCES MUST BE


OBSERVED AT ALL TIMES - REFER TO SPECIFIC
DRAWING NOTES AND FIXING DATASHEETS

MINIMUM 23 BEARING ON STRUCTURE AT ALL TIMES

TRACKS MUST NOT BE CUT AND FACETED ABOVE


OPENINGS WITHOUT KPS APPROVAL - CURVED
LINTELS AND CILLS CANNOT BE FORMED WITHOUT
ADDITIONAL RESTRAINT.
A
REFER TO DETAIL A.21 FOR SLOTTED STUD DETAILS

SD04 REVIEW/UPDATE 19.09.14 KPS

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

B
title: INFILL FRAMING
HEAD TRACK TO STEEL USING SLOTTED
STUD CONNECTION - CURVED OPTION 1
date 16.12.09 drg by KPS
scale NTS sheet A4
detail ref A.07S rev SD04
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

A HEAD TRACK FIXED TO STRUCTURE USING


FIXINGS AS SPECIFIED ON KPS DRAWINGS
WITH A MINIMUM OF 1 FIXING REQUIRED AT
TRACK JOINTS 50mm FROM BOTH TRACK
ENDS.

IMPORTANT - FIXING EDGE DISTANCES MUST BE


OBSERVED AT ALL TIMES - REFER TO SPECIFIC
DRAWING NOTES AND FIXING DATASHEETS

MINIMUM 32 BEARING ON STRUCTURE AT ALL TIMES

TRACKS MUST NOT BE CUT AND FACETED ABOVE


OPENINGS WITHOUT KPS APPROVAL - CURVED
LINTELS AND CILLS CANNOT BE FORMED WITHOUT
ADDITIONAL RESTRAINT.
A
REFER TO DETAIL A.21 FOR SLOTTED STUD
DETAILS

SD04 REVIEW/UPDATE 19.09.14 KPS

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: INFILL FRAMING


HEAD TRACK TO STEEL USING SLOTTED
STUD CONNECTION - CURVED OPTION 2
date 16.12.09 drg by KPS
scale NTS sheet A4
detail ref A.08S rev SD04
KINGSPAN STEEL BUILDING SOLUTIONS
A.03 BASE TRACK TO CONCRETE CONNECTION - STRAIGHT ref note

A BASE TRACK FIXED TO STRUCTURE USING


FIXINGS AS SPECIFIED ON KPS DRAWINGS
B 1 FIXING REQUIRED AT TRACK JOINTS 50mm
FROM BOTH TRACK ENDS.

IMPORTANT - FIXING EDGE DISTANCES MUST BE


OBSERVED AT ALL TIMES - REFER TO SPECIFIC
B DRAWING NOTES AND FIXING DATASHEETS

A.03 BASE TRACK TO CONCRETE CONNECTION - STRAIGHT MINIMUM 32 BEARING ON STRUCTURE AT ALL TIMES

TRACKS MUST NOT BE CUT AND FACETED ABOVE


OPENINGS WITHOUT KPS APPROVAL - CURVED
LINTELS AND CILLS CANNOT BE FORMED WITHOUT
ADDITIONAL RESTRAINT.

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: INFILL FRAMING


BASE TRACK TO CONCRETE
A CONNECTION - CURVED OPTION 1
date 16.12.09 drg by KPS
scale NTS sheet A4
detail ref A.09 rev SD03
KINGSPAN STEEL BUILDING SOLUTIONS
A.04 BASE TRACK TO STEEL CONNECTION - STRAIGHT ref note

A BASE TRACK FIXED TO STRUCTURE USING


FIXINGS AS SPECIFIED ON KPS DRAWINGS
WITH A MINIMUM OF 1 FIXING REQUIRED AT
TRACK JOINTS 50mm FROM BOTH TRACK
ENDS.

IMPORTANT - FIXING EDGE DISTANCES MUST BE


OBSERVED AT ALL TIMES - REFER TO SPECIFIC
A DRAWING NOTES AND FIXING DATASHEETS

A.04 BASE TRACK TO STEEL CONNECTION - STRAIGHT MINIMUM 32 BEARING ON STRUCTURE AT ALL TIMES

TRACKS MUST NOT BE CUT AND FACETED ABOVE


OPENINGS WITHOUT KPS APPROVAL - CURVED
LINTELS AND CILLS CANNOT BE FORMED WITHOUT
ADDITIONAL RESTRAINT.

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: INFILL FRAMING


BASE TRACK TO CONCRETE
CONNECTION - CURVED OPTION 2
date 16.12.09 drg by KPS
scale NTS sheet A4
detail ref A.10 rev SD03
KINGSPAN STEEL BUILDING SOLUTIONS
A.05s HEAD TRACK TO CONCRETE CONNECTION - CURVED ref note

A BASE TRACK FIXED TO STRUCTURE USING


FIXINGS AS SPECIFIED ON KPS DRAWINGS
B 1 FIXING REQUIRED AT TRACK JOINTS
50mm FROM BOTH TRACK ENDS.

IMPORTANT - FIXING EDGE DISTANCES MUST BE


OBSERVED AT ALL TIMES - REFER TO SPECIFIC
B
DRAWING NOTES AND FIXING DATASHEETS

A.05s HEAD TRACK TO CONCRETE CONNECTION - CURVED MINIMUM 32 BEARING ON STRUCTURE AT ALL TIMES

TRACKS MUST NOT BE CUT AND FACETED ABOVE


OPENINGS WITHOUT KPS APPROVAL - CURVED
LINTELS AND CILLS CANNOT BE FORMED WITHOUT
ADDITIONAL RESTRAINT.

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: INFILL FRAMING


BASE TRACK TO STEEL
A CONNECTION - CURVED OPTION 1
date 16.12.09 drg by KPS
scale NTS sheet A4
detail ref A.11 rev SD03
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

A BASE TRACK FIXED TO STRUCTURE USING


FIXINGS AS SPECIFIED ON KPS DRAWINGS
WITH A MINIMUM OF 1 FIXING REQUIRED AT
TRACK JOINTS 50mm FROM BOTH TRACK
ENDS.

IMPORTANT - FIXING EDGE DISTANCES MUST BE


OBSERVED AT ALL TIMES - REFER TO SPECIFIC
A
DRAWING NOTES AND FIXING DATASHEETS

A.06 HEAD TRACK TO CONCRETE CONNECTION - CURVED OPTION 2 MINIMUM 2


3 BEARING ON STRUCTURE AT ALL
TIMES

TRACKS MUST NOT BE CUT AND FACETED


ABOVE OPENINGS WITHOUT KPS APPROVAL -
CURVED LINTELS AND CILLS CANNOT BE
FORMED WITHOUT ADDITIONAL RESTRAINT .

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: INFILL FRAMING


U HEAD TRACK TO CONCRETE
CONNECTION - CURVED OPTION 2
date 16.12.09 drg by KPS
scale NTS sheet A4
detail ref A.12 rev SD03
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

STUD FIXED TO BASE TRACK USING 1no WAFER


HEAD 5.5mm SELF DRILLING TEK SCREW
THROUGH EACH TRACK FLANGE.

IMPORTANT - FIXING EDGE DISTANCES WITHIN


THE COLD ROLLED STEEL OF 3 x DIAMETER OF
THE FIXING MUST BE OBSERVED AT ALL TIMES -
REFER TO SPECIFIC DRAWING NOTES AND
FIXING DATASHEETS

FIXING MUST BE DRIVEN AT 90 DEGREES TO THE


FACE OF THE TRACK FLANGE.

MAXIMUM GAP FROM THE BOTTOM OF A STUD


TO THE BASE TRACK WEB IS 10mm.

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: INFILL FRAMING


STUD TO BASE TRACK CONNECTION

date 16.12.09 drg by KPS


scale NTS sheet A4
detail ref A.13 rev SD03
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

DEFLECTION HEAD BRACKET FIXED INTO HEAD


TRACK WITH 1no WAFER HEAD 5.5mm SELF DRILLING
TEK SCREW THROUGH EACH TRACK FLANGE.

DEFLECTION HEAD BRACKET FIXED FLUSH WITH THE


UNDERSIDE OF THE HEAD TRACK FLANGE TO ALLOW
FREE VERTICAL MOVEMENT OF THE STUD.

ENSURE A DEFLECTION GAP IS LEFT ABOVE THE


STUD (TYPICALLY 25mm BUT CHECK PROJECT
SPECIFIC DETAILS)

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: INFILL FRAMING


VERTICAL STUD TO HEAD TRACK USING
DHBs - TYPE 1 HEAD CLIP
date 16.12.09 drg by KPS
scale NTS sheet A4
detail ref A14 rev SD03
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

FLAT STRAP BRACING FIXED INTO STUD FLANGES


WITH 1no WAFER HEAD 5.5mm SELF DRILLING TEK
SCREW THROUGH EACH STUD FLANGE.

NOGGIN SECTIONS INSTALLED AS A TIGHT FIT


BETWEEN EVERY 3rd SET OF STUDS AND AT EVERY
END BAY USING 3no WAFER HEAD 5.5mm SELF
DRILLING TEK SCREW THROUGH EACH NOGGIN
FLANGE. NOGGIN LINE AT A MAXIMUM DIMENSION OF
400mm DOWN FROM TOP TRACK.

IMPORTANT - FIXING EDGE DISTANCES WITHIN SFS


SECTIONS OF 3 x DIAMETER OF THE FIXING MUST BE
OBSERVED AT ALL TIMES - REFER TO SPECIFIC
DRAWING NOTES AND FIXING DATASHEETS

ENSURE A DEFLECTION GAP IS LEFT ABOVE THE STUD


(TYPICALLY 25mm BUT CHECK PROJECT SPECIFIC
DETAILS)

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: INFILL FRAMING


VERTICAL STUD HEAD TRACK
DEFLECTION TYPE 2 - BLOCK & BRACE
date 16.12.09 drg by KPS
scale NTS sheet A4
detail ref A.15 rev SD03
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

NOGGIN SECTIONS INSTALLED AS A TIGHT FIT


BETWEEN EVERY STUD WITH A MINIMUM OF 1 FIXING
50mm FROM THE END OF THE SECTIONS THROUGH
THE HEAD TRACK INTO THE STRUCTURE BUT TO
MATCH THE PROJECT SPECIFIC FIXING DETAILS.

IMPORTANT - FIXING EDGE DISTANCES WITHIN SFS


SECTIONS OF 3 x DIAMETER OF THE FIXING MUST BE
OBSERVED AT ALL TIMES - REFER TO SPECIFIC
DRAWING NOTES AND FIXING DATASHEETS

ENSURE A DEFLECTION GAP IS LEFT ABOVE THE STUD


(TYPICALLY 25mm BUT CHECK PROJECT SPECIFIC
DETAILS)

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: INFILL FRAMING


HEAD BLOCKING CONNECTION

date 16.12.09 drg by KPS


scale NTS sheet A4
detail ref A.16 rev SD03
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

C SECTION VERTICAL STUDS JOINED THROUGH THE


WEBS AT 300mm STAGGERED CENTRES USING
5.5mm SELF DRILLING TEK SCREWS.

FIX BOTH STUDS THROUGH BASE TRACKS THROUGH


BOTH FLANGES USING 1no 5.5mm SELF DRILLING TEK
SCREW AS A.03.

IMPORTANT - FIXING EDGE DISTANCES WITHIN SFS


SECTIONS OF 3 x DIAMETER OF THE FIXING MUST BE
OBSERVED AT ALL TIMES - REFER TO SPECIFIC
DRAWING NOTES AND FIXING DATASHEETS

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: INFILL / OVERSAIL FRAMING


VERTICAL STUD
BACK TO BACK CONNECTION
date 16.12.09 drg by KPS
scale NTS sheet A4
detail ref A.17 rev SD03
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

C SECTION VERTICAL STUD IS FIXED TO THE


CONCRETE COLUMN USING FIXINGS AS DEFINED IN
THE PROJECT SPECIFIC DRAWING LEGEND.
MINIMUM OF 2no FIXINGS 50mm FROM HEAD AND
BASE OF THE STUD AND AT 300mm VERTICALLY
STAGGERED CENTRES.

FIX BOTH STUDS THROUGH BASE TRACKS THROUGH


BOTH FLANGES USING 1no 5.5mm SELF DRILLING
TEK SCREW.

IMPORTANT - FIXING EDGE DISTANCES WITHIN SFS


SECTIONS OF 3 x DIAMETER OF THE FIXING MUST BE
OBSERVED AT ALL TIMES - REFER TO SPECIFIC
DRAWING NOTES AND FIXING DATASHEETS.

EDGE DISTANCES IN CONCRETE VARY. CONSULT


PROJECT DETAILS.

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
NOTE - THIS IS NOT REQUIRED AT ALL Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
COLUMN LOCATIONS. PLEASE REFER TO
KINGSPAN ELEVATION DRAWINGS AND title: INFILL FRAMING
DETAILS FOR LOCATIONS. VERTICAL STUD TO CONC. COLUMN
CONNECTION
date 16.12.09 drg by KPS
scale NTS sheet A4
detail ref A.18 rev SD03
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

C SECTION VERTICAL STUD IS FIXED TO THE STEEL


COLUMN USING FIXINGS AS DEFINED IN THE PROJECT
SPECIFIC DRAWING LEGEND. MINIMUM OF 2no
FIXINGS 50mm FROM HEAD AND BASE OF THE STUD
AND AT 300mm VERTICALLY STAGGERED CENTRES.

FIX BOTH STUDS THROUGH BASE TRACKS THROUGH


BOTH FLANGES USING 1no 5.5mm SELF DRILLING TEK
SCREW.

IMPORTANT - FIXING EDGE DISTANCES WITHIN SFS


SECTIONS OF 3 x DIAMETER OF THE FIXING MUST BE
OBSERVED AT ALL TIMES - REFER TO SPECIFIC
DRAWING NOTES AND FIXING DATASHEETS

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
NOTE - THIS IS NOT REQUIRED AT ALL COLUMN Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
LOCATIONS. PLEASE REFER TO KINGSPAN
ELEVATION DRAWINGS AND DETAILS FOR title: INFILL FRAMING
LOCATIONS.
VERTICAL STUD TO STEEL COLUMN
CONNECTION
date 16.12.09 drg by KPS
scale NTS sheet A4
detail ref A.19 rev SD03
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

TRACKS MUST ABUT EACH OTHER. A FIXING TO BE


N.B. PRIMARY STRUCTURAL ELEMENTS NOT PLACED AT EACH END OF EACH TRACK 50mm FROM
SHOWN FOR CLARITY. CUT END. FIXING TYPE TO BE AS SPECIFICATION. NO
STUD TO BE WITHIN 150mm OF A TRACK JOINT.
A.14 VERTICAL STUD TO HEAD TRACK - SPLICE
NEVER TYPE 1 HEAD
LINTELS OR CILLS. CLIP
IMPORTANT - FIXING EDGE DISTANCES WITHIN SFS
SECTIONS OF 3 x DIAMETER OF THE FIXING MUST BE
OBSERVED AT ALL TIMES - REFER TO SPECIFIC
DRAWING NOTES AND FIXING DATASHEETS

REFER TO DETAIL A.21 FOR SLOTTED STUD DETAILS

SD05 REVIEW/UPDATE 19.09.14 KPS

SD04 REVIEW/UPDATE 23.10.12 KPS

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: INFILL FRAMING


TRACK JOINTS FIXING

date 16.12.09 drg by KPS


scale NTS sheet A4
detail ref A.20 rev SD05
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

THE SLOTTED STUD IS FIXED IN POSITION THROUGH


THE HEAD TRACK USING 5.5 WAFER HEAD FIXINGS
INTO BOTH FLANGES OF THE HEAD TRACK.
DEFLECTION ZONE MUST BE KEPT CLEAR OF ALL
FIXINGS AND NOT BE IMPEDED FROM MOVEMENT IN
ANY WAY. THE FIXING SHOULD BE POSITIONED
CENTRALLY AND THROUGH THE SLOTTED HOLE
A PROVIDED

A DEFLECTION GAP (TYPICALLY 25mm) TO BE


MAINTAINED AT ALL TIMES.

B FIXINGS TO BE MINIMUM 25mm LONG AND


5.5mm

IMPORTANT - FIXING EDGE DISTANCES WITHIN SFS


SECTIONS OF 3 x DIAMETER OF THE FIXING MUST BE
OBSERVED AT ALL TIMES - REFER TO SPECIFIC
DRAWING NOTES AND FIXING DATASHEETS

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

B SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: INFILL FRAMING


STUD TO HEAD TRACK CONNECTION
SLOTTED
date 16.12.09 drg by KPS
scale NTS sheet A4
detail ref A.21 rev SD03
KINGSPAN STEEL BUILDING SOLUTIONS
CAL STUD TO HEAD TRACK - TYPE 3 HEAD TRACK BLOCKING
ref note

A FS3809 FLAT STRAP BRACING FIXED TO JAMB STUD


25mm BELOW HEAD TRACK USING MIN 4no. 5.5mm
SELF DRILLING TEK SCREWS. FIX TO LINTEL TRACK
FLANGE AT CRIPPLE STUD LOCATION USING MIN 4no.
5.5mm SELF DRILLING TEK SCREWS. ENSURE FLAT
STRAP IS PULLED TIGHT AND FIXED TO BOTH SIDES
OF THE STUD WALL. TYPE 3 HEAD BLOCKING (DETAIL
A.16) MUST BE USED ABOVE OPENINGS AT THE BAY
ADJACENT TO THE JAMB WHERE FLAT STRAP
BRACING IS EMPLOYED.

A DEFLECTION GAP (TYPICALLY 25mm) TO BE


MAINTAINED AT ALL TIMES.

IMPORTANT - FIXING EDGE DISTANCES WITHIN SFS


SECTIONS OF 3 x DIAMETER OF THE FIXING MUST BE
OBSERVED AT ALL TIMES - REFER TO SPECIFIC
DRAWING NOTES AND FIXING DATASHEETS

SD05 REVIEW/UPDATE 19.09.14 KPS

SD04 REVIEW/UPDATE 23.10.12 KPS

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: INFILL FRAMING


FLAT STRAP BRACING DETAIL

date 16.12.09 drg by KPS


scale NTS sheet A4
detail ref A.22 rev SD05
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

OCKING VERTICAL STUD IS FIXED INTO 6mm PLATES - BY


OTHERS (6mm PLATES TO BE WELDED FLUSH WITH
HR STEELWORK) TO SPECIFICATION. MINIMUM
REQUIREMENT - 50mm DEEP PLATE AT HEAD AND
BASE OF STUD OR CRIPPLE STUD OVER WINDOW.

C SECTION VERTICAL STUD IS FIXED TO THE STEEL


COLUMN USING FIXINGS AS DEFINED IN THE
PROJECT SPECIFIC DRAWING LEGEND. MINIMUM OF
2no FIXINGS 50mm FROM HEAD AND BASE OF THE
STUD.

FIX STUD THROUGH BASE TRACK FLANGES USING


1no 5.5mm SELF DRILLING TEK SCREW.

IMPORTANT - FIXING EDGE DISTANCES WITHIN SFS


SECTIONS OF 3 x DIAMETER OF THE FIXING MUST BE
OBSERVED AT ALL TIMES - REFER TO SPECIFIC
DRAWING NOTES AND FIXING DATASHEETS

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
NOTE - THIS IS NOT REQUIRED AT ALL COLUMN Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
LOCATIONS. PLEASE REFER TO KINGSPAN
ELEVATION DRAWINGS AND DETAILS FOR title: INFILL FRAMING
LOCATIONS.
VERTICAL STUD TO STEEL CLOUMN
CONNECTION - WELDED PLATES
date 16.12.09 drg by KPS
scale NTS sheet A4
detail ref A.23 rev SD03
KINGSPAN STEEL BUILDING SOLUTIONS
A.18 VERTICAL STUD TO CONCRETE COLUMN ref note

300mm SECTIONS OF 'C' STUD ARE PRE-ASSEMBLED


INTO A CONTINUOUS SECTION OF 'U' TRACK WITH
5.5mm COLD ROLLED TEK SCREWS THROUGH THE
FLANGES AT 100mm CTS.

THE ASSEMBLY IS FIXED INTO THE WEB OF THE


COLUMN USING PAIRS OF FIXINGS AT 300mm CTS.

THE VERTICAL STUD IS THEN FIXED INTO THE 300mm


SECTIONS OF STUD WITH PAIRS OF 5.5mm COLD
ROLLED TEK SCREWS THROUGH THE WEBS AT
300mm CTS.

IMPORTANT - FIXING EDGE DISTANCES WITHIN SFS


SECTIONS OF 3 x DIAMETER OF THE FIXING MUST BE
OBSERVED AT ALL TIMES - REFER TO SPECIFIC
DRAWING NOTES AND FIXING DATASHEETS

SECTION A-A
SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES

A.24 VERTICAL
NOTE - THIS ISSTUD TO STEEL
NOT REQUIRED AT ALL COLUMN WITH PACKING STUDS Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
COLUMN LOCATIONS. PLEASE REFER TO
KINGSPAN ELEVATION DRAWINGS AND title: INFILL FRAMING
DETAILS FOR LOCATIONS. VERTICAL STUD TO STEEL COLUMNS
CONNECTION - PACKING STUDS
date 16.12.09 drg by KPS
scale NTS sheet A4
detail ref A.24 rev SD03
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

A.25a
A HEAD TRACK FIXED TO SFS TRACK/ANGLES
USING FIXINGS AS SPECIFIED ON KPS
DRAWINGS
B ANGLE TO BE SPECIFIED PROJECT BY
PROJECT.
IMPORTANT - FIXING EDGE DISTANCES MUST BE
FIXINGS REQUIRED AT 300mm crs. OBSERVED AT ALL TIMES - REFER TO SPECIFIC
DRAWING NOTES AND FIXING DATASHEETS

REFER TO DETAIL A.21 FOR SLOTTED STUD DETAILS


REFER TO DETAIL A01 AND A02 FOR BEARING
A DETAILS.

FIXINGS REQUIRED AT 300mm crs.

A.25b

SFS TRACK FIXING TO PARAPET PFC

SD01 SPECIFICATION 09.10.14 KPS

ref revision date by

A B
STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

SFS ANGLE FIXING TO PARAPET PFC title: INFILL FRAMING


TO BE USED IF THE WIDTH OF THE PFC DOES NOT ALLOW HEAD TRACK FIXINGS AT
FOR A SFS TRACK TO BE FIXED AT BOTH FLANGES PFC PARAPETS
HEAD TRACK TO FIX TO BOTH ANGLES.
date 09.10.14 drg by KSBS
scale NTS sheet A4
detail ref A25 rev SD01
KINGSPAN STEEL BUILDING SOLUTIONS
6.2 B Series Construction Details
Rev.
B.01 Mid Span Restraint Midspan Restraint SD03
B.02s Penetrations Penetration through Head Track (inter stud) Slotted Stud SD03
B.03s Penetrations Penetration through Head Track (on stud) Slotted Stud SD04
B.04 Window Support Cill Angle SD04
B.05 Window Support Cill Plate SD04
B.06s Head Track Support Z Bar Slotted Stud SD04
B.07 Track Support Edge Angle SD03
B.08 Penetrations -Scaffold Penetration through Head Track (on stud) SD05
B.09 Penetrations -Scaffold Penetration through Head Track (B/W Studs) SD04
B.10 Penetrations -Scaffold Penetration through Head Track (At Jambs) SD05

These details are shown on the following pages.

53
ref note

FLAT STRAP BRACING FIXED INTO STUD FLANGES


WITH 1no WAFER HEAD 5.5mm SELF DRILLING TEK
SCREW THROUGH EACH STUD FLANGE.

NOGGIN 'C' SECTIONS INSTALLED AS A TIGHT FIT


BETWEEN EVERY 3rd SET OF STUDS USING 3no
WAFER HEAD 5.5mm SELF DRILLING TEK SCREWS
THROUGH EACH NOGGIN FLANGE.

JOINTS IN STRAP TO ABUT ON THE CENTERLINE OF


STUDS.

IMPORTANT - FIXING EDGE DISTANCES WITHIN SFS


SECTIONS OF 3 x DIAMETER OF THE FIXING MUST BE
OBSERVED AT ALL TIMES - REFER TO SPECIFIC
DRAWING NOTES AND FIXING DATASHEETS

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: INFILL / OVERSAIL FRAMING


MIDSPAN RESTRAINT

date 16.12.09 drg by KPS


scale NTS sheet A4
B.01 MID SPAN RESTRAINT - BLOCK AND BRACE NOGGIN
detail ref B.01 rev SD03
KINGSPAN STEEL BUILDING SOLUTIONS
notes

HEAD TRACK ENDS MUST HAVE A FIXING NO MORE


THAN 50mm FROM THE CUT END AS INDICATED ON
THE SPECIFICATION. STUDS MUST BE NO CLOSER
THAN 150mm FROM THE CUT IN THE HEAD TRACK. IF
THIS IS NOT POSSIBLE, USE DETAIL B.03

IMPORTANT - FIXING EDGE DISTANCES WITHIN SFS


SECTIONS OF 3 x DIAMETER OF THE FIXING MUST BE
OBSERVED AT ALL TIMES - REFER TO SPECIFIC
DRAWING NOTES AND FIXING DATASHEETS

ENSURE A DEFLECTION GAP IS LEFT ABOVE THE


STUD (TYPICALLY 25mm BUT CHECK PROJECT
SPECIFIC DETAILS)

REFER TO DETAIL A.21 FOR SLOTTED STUD DETAILS

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: INFILL FRAMING


PENETRATION THROUGH HEAD TRACK
INTER STUD - SLOTTED
date 16.12.09 drg by KPS
scale NTS sheet A4
detail ref B.02S rev SD03
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

VERTICAL STUD ON THE (TYPICAL) 600mm GRID MAY


BE CUT SHORT AND A CONVENTIONAL CILL FORMED
BELOW SERVICE PENETRATION BETWEEN
ADDITIONAL 150mm LONG CRIPPLE STUDS EITHER
SIDE OF THE GRID STUD. SEE DETAIL C.01

IMPORTANT - FIXING EDGE DISTANCES WITHIN SFS


SECTIONS OF 3 x DIAMETER OF THE FIXING MUST BE
OBSERVED AT ALL TIMES - REFER TO SPECIFIC
DRAWING NOTES AND FIXING DATASHEETS

ENSURE A DEFLECTION GAP IS LEFT ABOVE THE STUD


(TYPICALLY 25mm BUT CHECK PROJECT SPECIFIC
DETAILS)

NOTE: DEPENDING ON THE BOARD FIXING


REQUIREMENTS, THE 150mm LONG CRIPPLE STUD
MAY NEED TO BE LENGTHENED TO SUPPORT THE
BOARDING. SEEK GUIDANCE FROM THE BOARD
INSTALLER OR THE PROJECT DESIGN TEAM FOR ANY
SPECIFIC REQUIREMENTS.

REFER TO DETAIL A.21 FOR SLOTTED STUD DETAILS

SD04 REVIEW/UPDATE 23.10.12 KPS

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: INFILL FRAMING


PENETRATION THROUGH HEAD TRACK
ON STUD - SLOTTED
date 16.12.09 drg by KPS
scale NTS sheet A4
detail ref B.03S rev SD04
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

NON STANDARD ANGLE - PROJECT SPECIFIC DESIGN.


PLEASE CONSULT KINGSPAN FOR SPECIFICATION.

FIXED TO CILL TRACK AS PER FIXING SPECIFICATION


GIVEN IN THE PROJECT DETAIL DRAWING LEGEND.

SD04 REVIEW/UPDATE 23.10.12 KPS

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: INFILL / OVERSAIL FRAMING


WINDOW SUPPORT
CILL ANGLE CONNECTION
date 16.12.09 drg by KPS
scale NTS sheet A4
detail ref B.04 rev SD04
KINGSPAN STEEL BUILDING SOLUTIONS
RD ANGLE (REFER ref note

NON STANDARD PLATE - PROJECT SPECIFIC DESIGN.


OR SPECIFICATION) PLEASE CONSULT KINGSPAN FOR SPECIFICATION.

FIXED TO CILL TRACK AS PER FIXING SPECIFICATION


GIVEN IN THE PROJECT DETAIL DRAWING LEGEND.
CATION GIVEN IN

SD04 REVIEW/UPDATE 23.10.12 KPS

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: INFILL / OVERSAIL FRAMING


WINDOW SUPPORT
CILL PLATE
date 16.12.09 drg by KPS
scale NTS sheet A4
detail ref B.05 rev SD04
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

'Z' BAR Z40404016 TO BE FITTED TO PRIMARY


STRUCTURE USING FIXING SPECIFICATION GIVEN IN
THE LEGEND. HEAD TRACK TO BE FIXED TO 'Z' BAR
USING A MIMUMUM OF 2 FIXINGS TO THE
SPECIFICATION. 'Z' BARS TO BE PLACED AT
HORIZONTAL CENTRES AS INDICATED ON THE
ELEVATION.

IMPORTANT - FIXING EDGE DISTANCES WITHIN SFS


SECTIONS OF 3 x DIAMETER OF THE FIXING MUST BE
OBSERVED AT ALL TIMES - REFER TO SPECIFIC
DRAWING NOTES AND FIXING DATASHEETS

ENSURE A DEFLECTION GAP IS LEFT ABOVE THE STUD


(TYPICALLY 25mm BUT CHECK PROJECT SPECIFIC
DETAILS)

ADDITIONAL ZED BARS REQUIRED AT TRACK ENDS


AND JAMB STUD LOCATIONS.

REFER TO DETAIL A.21 FOR SLOTTED STUD DETAILS

SD04 REVIEW/UPDATE 25.07.13 KPS

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: INFILL FRAMING


HEAD TRACK SUPPORT
ZED BAR - SLOTTED STUDS
date 16.12.09 drg by KPS
scale NTS sheet A4
detail ref B.06S rev SD04
KINGSPAN STEEL BUILDING SOLUTIONS
MID SPAN RESTRAINT - BLOCK AND BRACE NOGGIN
ref note

WHERE 2/3 BEARING IS NOT ACHIEVED WHEN FIXING


TO CONCRETE NON STANDARD ANGLE REQUIRED.

FIXING SPECIFICATION GIVEN IN THE LEGEND IS A


STRUCTURAL MINIMUM AND MUST BE OBSERVED IN
ALL INSTANCES - IF IN DOUBT REFER TO KINGSPAN.

IMPORTANT - FIXING EDGE DISTANCES WITHIN SFS


SECTIONS OF 3 x DIAMETER OF THE FIXING MUST BE
OBSERVED AT ALL TIMES - REFER TO SPECIFIC
DRAWING NOTES AND FIXING DATA SHEETS

FIXING EDGE DISTANCES IN CONCRETE SHOULD BE IN


ACCORDANCE WITH KINGSPAN DETAILS AND
MANUFACTURER DATA SHEETS.

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: TRACK SUPPORT


EDGE DETAIL
CONNECTION
date 16.12.09 drg by KPS
scale NTS sheet A4
detail ref B.07 rev SD03
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

VERTICAL STUD ON THE (TYPICAL) 600mm GRID MAY


BE CUT SHORT AND A CONVENTIONAL CILL FORMED
BELOW SCAFFOLDING PENETRATION BETWEEN
ADDITIONAL 150mm LONG CRIPPLE STUDS EITHER
SIDE OF THE GRID STUD. SEE DETAIL C.01

IMPORTANT - FIXING EDGE DISTANCES WITHIN SFS


SECTIONS OF 3 x DIAMETER OF THE FIXING MUST BE
OBSERVED AT ALL TIMES - REFER TO SPECIFIC
DRAWING NOTES AND FIXING DATASHEETS

ENSURE A DEFLECTION GAP IS LEFT ABOVE THE STUD


(TYPICALLY 25mm BUT CHECK PROJECT SPECIFIC
DETAILS)

REFER TO DETAIL A.21 FOR SLOTTED STUD DETAILS

SD05 REVIEW/UPDATE 19.09.14 KPS

SD04 REVIEW/UPDATE 23.10.12 KPS

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
N.B. TRACKS MUST NOT BE CUT AT JAMB
STUD LOCATIONS. title: SCAFFOLD PENETRATION THROUGH
HEAD TRACK - ON STUD

date 16.12.09 drg by KPS


scale NTS sheet A4
detail ref B.08 rev SD05
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

HEAD TRACK ENDS MUST HAVE A FIXING NO MORE


THAN 50mm FROM THE CUT END AS INDICATED ON
THE SPECIFICATION. STUDS MUST BE NO CLOSER
THAN 150mm FROM THE CUT IN THE HEAD TRACK. IF
THIS IS NOT POSSIBLE, USE DETAIL B.08

IMPORTANT - FIXING EDGE DISTANCES WITHIN SFS


SECTIONS OF 3 x DIAMETER OF THE FIXING MUST BE
OBSERVED AT ALL TIMES - REFER TO SPECIFIC
DRAWING NOTES AND FIXING DATASHEETS

ENSURE A DEFLECTION GAP IS LEFT ABOVE THE STUD


(TYPICALLY 25mm BUT CHECK PROJECT SPECIFIC
DETAILS)

REFER TO DETAIL A.21 FOR SLOTTED STUD DETAILS

SD04 REVIEW/UPDATE 19.09.14 KPS

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
N.B. TRACKS MUST NOT BE CUT AT JAMB
STUD LOCATIONS. title: SCAFFOLDING PENETRATION THROUGH
HEAD TRACK - BETWEEN STUDS

date 16.12.09 drg by KPS


scale NTS sheet A4
detail ref B.09 rev SD04
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

SCAFFOLDING BARS MUST NOT CLASH WITH SFS


JAMB STUD POSITIONS WITHOUT KPS ASSESSMENT.

SCAFFOLDING CAN ONLY BE MOVED BY A SUITABLY


QUALIFIED PERSON.

THE TRACK MUST NOT BE CUT WITHIN 300mm OF THE


JAMB STUD.

ENSURE FIXINGS ARE INSTALLED WITHIN 50mm OF


THE EDGES OF THE CUT TRACK (TO DRAWING
SPECIFICATION).

REFER TO DETAIL A.21 FOR SLOTTED STUD DETAILS

SD05 REVIEW/UPDATE 19.09.14 KPS

SD04 REVIEW/UPDATE 23.10.12 KPS

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: SCAFFOLD PENETRATION THROUGH


HEAD TRACK AT JAMB

date 16.12.09 drg by KPS


scale NTS sheet A4
detail ref B.10 rev SD05
KINGSPAN STEEL BUILDING SOLUTIONS
6.3 C Series Opening Construction
Rev.
C.01 Cill Construction Single Track SD04
C.02 Cill Construction Single Stud & Double Track SD04
C.03 Cill Construction Patio Door Threshold SD04
C.04s Lintel Construction Single Track Using Slotted Stud SD05
C.05s Lintel Construction Slotted Single Stud over 600mm On Double Track SD04
C.06s Lintel Construction Slotted Stud, Double Studs over 600mm on Triple Track SD05
C.07s Lintel Construction Quadruple Track and Single Stud - Slotted Stud SD04
C.08 Lintel Construction Beam Lintel SD05
C.09s Jamb Construction Single Stud Slotted Stud SD04
C.10s Jamb Construction Single Stud & Single Track - Slotted Stud SD04
C.11s Jamb Construction Double Stud & Single Track Slotted Stud SD04
C.12s Jamb Construction Double Stud & Double Track Slotted Stud SD04
C.13 Jamb Construction High Load Cleat (Head) SD05
C.14 Jamb Construction High Load Cleat (Base) SD05
C.15 High Load Cleat With Zed Bar Connection SD05
C.16 Head Track Reinforcement at Jamb Stud Position SD02
C.17 Head Track Reinforcement at Jamb Stud Position SD02
C.18 Hot rolled restraint post Lintel Connection SD02
C.18a Kingpost - Lintel Connection SD01
C.19 Hot rolled restraint post Cill Connection SD02
C.19a Kingpost - Cill Connection SD01

These details are shown on the following pages

64
ref note

Min. 150mm LONG END CRIPPLE STUD FIXED TO JAMB


STUD USING A MINIMUM 4 no. WAFER HEAD 5.5mm
SELF DRILLING TEK SCREWS.

CILL TRACK CONNECTION MADE USING 1 FIXING INTO


BOTH FLANGES OF THE CILL TRACK ON THE
INTERSECTION OF CENTRE LINE OF BOTH THE TRACK
AND THE STUD.

IMPORTANT - FIXING EDGE DISTANCES WITHIN SFS


SECTIONS OF 3 x DIAMETER OF THE FIXING MUST BE
OBSERVED AT ALL TIMES - REFER TO SPECIFIC
DRAWING NOTES AND FIXING DATASHEETS

NOTE: DEPENDING ON THE BOARD FIXING


REQUIREMENTS, THE 150mm LONG CRIPPLE STUD
MAY NEED TO BE LENGTHENED TO SUPPORT THE
BOARDING. SEEK GUIDANCE FROM THE BOARD
INSTALLER OR THE PROJECT DESIGN TEAM FOR ANY
SPECIFIC REQUIREMENTS.

SD04 REVIEW/UPDATE 23.10.12 KPS

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: CILL CONSTRUCTION


SINGLE TRACK

NOTES: ALL CILL SECTIONS ARE TO BE FULL LENGTH AND MUST NOT BE SPLICED date 16.12.09 drg by KPS
SLOTTED STUDS ARE NOT TO BE USED TO UNDERSIDE OF CILL. scale NTS sheet A4
detail ref C.01 rev SD04
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

FIX LOWER CILL TRACK AND CRIPPLE STUDS AS


DETAIL C.01

A 50x50x2mm CLEAT TO BE INSTALLED AT CILL /


LINTEL LEVEL OF ALL NESTED CILL AND LINTEL
MEMBERS WITH A MINIMUM OF 2 WAFER HEAD
5.5mm SELF DRILLING TEK SCREWS PER CLEAT
LEG
A
B STUD SECTION FITTED WITH WAFER HEAD
B 5.5mm SELF DRILLING TEK SCREWS AT 300mm
STAGGERED CENTRES THROUGH THE WEB TO
LOWER CILL TRACK.
C NESTED CILL TRACK FIXED TO THE STUD
C BELOW WITH WAFER HEAD 5.5mm SELF
DRILLING TEK SCREWS @ 300mm CENTRES
THROUGH BOTH FLANGES

NOTE: DEPENDING ON THE BOARD FIXING


REQUIREMENTS, THE 150mm LONG CRIPPLE STUD
MAY NEED TO BE LENGTHENED TO SUPPORT THE
BOARDING. SEEK GUIDANCE FROM THE BOARD
INSTALLER OR THE PROJECT DESIGN TEAM FOR ANY
SPECIFIC REQUIREMENTS.

SD04 REVIEW/UPDATE 23.10.12 KPS

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: CILL CONSTRUCTION


SINGLE STUD, DOUBLE TRACK

NOTES: ALL CILL SECTIONS ARE TO BE FULL LENGTH AND MUST NOT BE SPLICED date 16.12.09 drg by KPS
SLOTTED STUDS ARE NOT TO BE USED TO UNDERSIDE OF CILL. scale NTS sheet A4
detail ref C.02 rev SD04
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

STUD SECTION NESTED INTO THE BASE TRACK AND


FIXED WITH WAFER HEAD 5.5mm SELF DRILLING TEK
SCREWS @ 300mm CENTRES THROUGH BOTH
FLANGES

15mm
MIN
20mm SD04 REVIEW/UPDATE 23.10.12 KPS
MIN SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: CILL CONSTRUCTION


DOOR THRESHOLD
Note: TRACK MUST BE FIXED DOWN TO SUBSTRATE PRIOR TO INSTALLING STUD
INSERT. SEE PROJECT SPECIFIC KINGSPAN DRAWINGS FOR FIXING SPECIFICATIONS date 16.12.09 drg by KPS
scale NTS sheet A4
detail ref C.03 rev SD04
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

MIN 150MM LONG CRIPPLE STUD FIXED TO JAMB


STUD USING A MINIMUM 4 WAFER HEAD 5.5mm SELF
DRILLING TEK SCREWS. LINTEL TRACK CONNECTION
MADE USING 2 FIXINGS INTO BOTH FLANGES OF THE
LINTEL TRACK ON THE INTERSECTION OF CENTRE
LINE OF BOTH THE TRACK AND THE STUD.1No FIXINGS
REQUIRED FOR ALL INTERMEDIATE CRIPPLE STUDS.

IMPORTANT - FIXING EDGE DISTANCES WITHIN SFS


SECTIONS OF 3 x DIAMETER OF THE FIXING MUST BE
OBSERVED AT ALL TIMES - REFER TO SPECIFIC
DRAWING NOTES AND FIXING DATASHEETS

ENSURE A DEFLECTION GAP IS LEFT ABOVE THE STUD


(TYPICALLY 25mm BUT CHECK PROJECT SPECIFIC
DETAILS)

NOTE: DEPENDING ON THE BOARD FIXING


REQUIREMENTS, THE 150mm LONG CRIPPLE STUD
MAY NEED TO BE LENGTHENED TO SUPPORT THE
BOARDING. SEEK GUIDANCE FROM THE BOARD
INSTALLER OR THE PROJECT DESIGN TEAM FOR ANY
SPECIFIC REQUIREMENTS.
SD05 REVIEW/UPDATE 19.09.14 KPS

SD04 REVIEW/UPDATE 23.10.12 KPS

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: LINTEL CONSTRUCTION


SINGLE TRACK - SLOTTED STUDS
OVER 600mm
date 16.12.09 drg by KPS
NOTE: ALL CILL SECTIONS ARE TO BE FULL LENGTH AND MUST NOT BE SPLICED scale NTS sheet A4
detail ref C.04S rev SD05
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

FIX UPPER CRIPPLE STUDS AND LINTEL TRACK AS


PER STANDARD DETAIL C04s

A 50x50x2mm CLEAT TO BE INSTALLED AT CILL /


LINTEL LEVEL OF ALL NESTED CILL AND
LINTEL MEMBERS WITH A MINIMUM OF 2
WAFER HEAD 5.5mm SELF DRILLING TEK
SCREWS PER CLEAT LEG

B STUD SECTION (TO DESIGN) FITTED WITH


WAFER HEAD 5.5mm SELF DRILLING TEK
SCREWS AT 300mm STAGGERED CENTRES
THROUGH THE WEB TO UPPER LINTEL
TRACK.

C NESTED LINTEL TRACK FIXED TO THE STUD


ABOVE WITH WAFER HEAD 5.5mm SELF
DRILLING TEK SCREWS @ 300mm CENTRES
THROUGH BOTH FLANGES

SD04 REVIEW/UPDATE 23.10.12 KPS

SD03 REVIEW/UPDATE 01.05.12 KPS


A SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by


C

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
B
title: LINTEL CONSTRUCTION - SLOTTED SINGLE
STUD OVER 600mm ON DOUBLE TRACK

date 16.12.09 drg by KPS


scale NTS sheet A4
NOTE: ALL CILL SECTIONS ARE TO BE FULL LENGTH AND MUST NOT BE SPLICED detail ref C.05S rev SD04
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

FIX UPPER CRIPPLE STUDS AND LINTEL TRACK AS


PER STANDARD DETAIL C04s

A TRACK SECTION FITTED BACK TO BACK WITH


UPPER LINTEL TRACK USING 5.5mm WAFER
HEAD SELF DRILLING TEK SCREWS @ 300mm
STAGGERED CENTRES

B 2 NO. STUD SECTIONS FITTED WITH


VERTICAL WEBS INTO TRACK SECTION WITH
WAFER HEAD 5.5mm SELF DRILLING TEK
SCREWS AT 300mm CENTRES THROUGH
BOTH FLANGES

C LOWER LINTEL TRACK SECTION FITTED TO


WEBS OF STUD SECTIONS AS PER POINT B.

ENSURE THAT THE LOWER LINTEL TRACK IS


CLEATED TO BOTH JAMB STUDS USING 50x50x2mm
CLEATS AND 2no WAFER HEAD 5.5mm SELF
DRILLING TEK SCREWS THROUGH BOTH ANGLE
LEGS

SD05 REVIEW/UPDATE 19.09.14 KPS

SD04 REVIEW/UPDATE 23.10.12 KPS

A SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS


B
ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: LINTEL CONSTRUCTION - SLOTTED STUD


DOUBLE STUDS OVER 600mm
TRIPLE TRACK
C date 16.12.09 drg by KPS
scale NTS sheet A4
NOTE: ALL CILL SECTIONS ARE TO BE FULL LENGTH AND MUST NOT BE SPLICED detail ref C.06S rev SD05
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

FIX UPPER CRIPPLE STUDS AND LINTEL TRACK AS


PER STANDARD DETAIL C04s

A TRACK SECTION FITTED BACK TO BACK WITH


UPPER LINTEL TRACK USING 5.5mm WAFER HEAD
SELF DRILLING TEK SCREWS @ 300mm STAGGERED
CENTRES

B 1 NO. STUD SECTION & 1 NO. TRACK SECTION


NESTED & FITTED WITH VERTICAL WEBS INTO TRACK
SECTION WITH WAFER HEAD 5.5mm SELF DRILLING
TEK SCREWS AT 300mm CENTRES THROUGH BOTH
FLANGES

C LOWER LINTEL TRACK SECTION FITTED TO


WEBS OF NESTED STUD SECTIONS AS PER POINT B.

A ENSURE THAT THE LOWER LINTEL TRACK IS CLEATED


TO BOTH JAMB STUDS USING 50x50x2mm CLEATS AND
2no WAFER HEAD 5.5mm SELF DRILLING TEK SCREWS
THROUGH BOTH ANGLE LEGS
B

SD04 REVIEW/UPDATE 23.10.12 KPS

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL
C
Steel Building
C.07s LINTEL CONSTRUCTION - QUADRUPLE TRACK & SINGLE STUD Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: LINTEL CONSTRUCTION


SINGLE STUD, QUADRUPLE TRACK

date 16.12.09 drg by KPS


scale NTS sheet A4
NOTE: ALL CILL SECTIONS ARE TO BE FULL LENGTH AND MUST NOT BE SPLICED detail ref C.07S rev SD04
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

HORIZONTAL STUD SECTION USED TO FORM LINTEL


C.02 CILL CONSTRUCTION - DOUBLE TRACK & SINGLE STUD C.03 CILL CONSTRUCTION
TO KINGSPAN SPECIFICATION. - PATIO D
ENSURE THAT THE LINTEL STUD IS CLEATED TO BOTH
JAMB STUDS USING 50x50x2mm CLEATS AND 2no
WAFER HEAD 5.5mm SELF DRILLING TEK SCREWS
THROUGH BOTH ANGLE LEGS.
HEAD TRACK
NO FIXINGS REQUIRED TO TRACK & HORIZONTAL
STUD TO ALLOW DEFLECTION

INDICATES WINDOW TO ACCOMMODATE


DEFLECTION WHERE 25mm DEFLECTION IS
UNACHIEVABLE

JAMB STUD
(DETAIL
HANDED AT
OPPOSITE
JAMB)

SD05 REVIEW/UPDATE 19.09.14 KPS

SD04 REVIEW/UPDATE 23.10.12 KPS

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: LINTEL CONSTRUCTION


BEAM LINTEL

date 16.12.09 drg by KPS


scale NTS sheet A4
detail ref C.08 rev SD05
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

SINGLE 'C' SECTION JAMB STUD FIXED TO BASE


TRACK USING A MINIMUM OF ONE FIXING EACH SIDE
OF THE JAMB. METHOD OF RESTRAINT AT HEAD
VARIES DEPENDING ON BLOCKING TYPE (TYPE 4 -
SLOTTED STUD SHOWN HERE).
ENSURE FIXINGS FOR BOTH HEAD AND BASE TRACK
ARE WITHIN 50mm OF THE POSITION OF THE JAMB
STUD. REFER TO LEGEND FOR SPECIFIC FIXING
SPECIFICATIONS.

SD04 REVIEW/UPDATE 23.10.12 KPS

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SECTION A-A SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: JAMB CONSTRUCTION


SINGLE JAMB (SLOTTED)

date 16.12.09 drg by KPS


scale NTS sheet A4
detail ref C.09S rev SD04
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

SINGLE 'C' SECTION JAMB STUD FIXED TO BASE


TRACK USING A MINIMUM OF ONE FIXING EACH SIDE
OF THE JAMB. REFER TO LEGEND FOR SPECIFIC
FIXING SPECIFICATIONS FOR CONNECTIONS TO
STRUCTURE.

SLEEVING 'U' SECTION FIXED TO 'C' SECTION AT


300mm CTS ON BOTH LEGS OF 'U' SECTION AND AT
50mm FROM EACH END. 40mm MINIMUM DISTANCE
BETWEEN HEAD TRACK AND SLEEVE TRACK
REQUIRED FOR DEFLECTION. REFER TO THE
SPECIFICATION FOR SECTION DETAILS.

SD04 REVIEW/UPDATE 23.10.12 KPS

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SECTION A-A SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: JAMB CONSTRUCTION


SINGLE SLOTTED STUD & SINGLE TRACK

MB CONSTRUCTION - SINGLE STUD & SINGLE TRACK date 16.12.09 drg by KPS
scale NTS sheet A4
detail ref C.10S rev SD04
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

DOUBLE 'C' SECTION JAMB STUD FIXED TO BASE


TRACK USING A MINIMUM OF ONE FIXING EACH SIDE
OF THE JAMB. REFER TO LEGEND FOR SPECIFIC
FIXING SPECIFICATIONS FOR CONNECTIONS TO
STRUCTURE.

TRACK SECTIONS FIXED TO JAMB STUD THROUGH


WEBS USING FIXINGS AT 300mm STAGGERED CTS &
AT 50mm FROM EACH END.

SLEEVING 'U' SECTION FIXED TO 'C' SECTION AT


300mm CTS ON BOTH LEGS OF 'U' SECTION AND AT
50mm FROM EACH END. 40mm MINIMUM DISTANCE
BETWEEN HEAD TRACK AND SLEEVE TRACK
REQUIRED FOR DEFLECTION. REFER TO THE
SPECIFICATION FOR SECTION DETAILS.

SD04 REVIEW/UPDATE 23.10.12 KPS

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SECTION A-A SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: JAMB CONSTRUCTION


DOUBLE SLOTTED STUD & SINGLE TRACK

date 16.12.09 drg by KPS


scale NTS sheet A4
detail ref C.11S rev SD04
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

DOUBLE 'C' SECTION JAMB STUD FIXED TO BASE


TRACK USING A MINIMUM OF ONE FIXING EACH
SIDE OF THE JAMB. REFER TO LEGEND FOR
SPECIFIC FIXING SPECIFICATIONS FOR
CONNECTIONS TO STRUCTURE.

TRACK SECTIONS FIXED TO JAMB STUD


THROUGH WEBS USING FIXINGS AT 300mm
STAGGERED CTS & AT 50mm FROM EACH END.

SLEEVING 'U' SECTION FIXED TO 'C' SECTION AT


300mm CTS ON BOTH LEGS OF 'U' SECTION AND
AT 50mm FROM EACH END. 40mm MINIMUM
DISTANCE BETWEEN HEAD TRACK AND SLEEVE
TRACK REQUIRED FOR DEFLECTION. REFER TO
THE SPECIFICATION FOR SECTION DETAILS.

SD04 REVIEW/UPDATE 23.10.12 KPS

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SECTION A-A SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: JAMB CONSTRUCTION


DOUBLE SLOTTED STUD & DOUBLE TRACK

date 16.12.09 drg by KPS


scale NTS sheet A4
detail ref C.12S rev SD04
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

ALL HIGH LOAD CLEATS ARE TO BE FIXED TO THE


PRIMARY STRUCTURE IN ACCORDANCE WITH THE
SPECIFIC FIXING SPECIFICATION SET OUT BY
KINGSPAN.

THE WEB OF THE JAMB STUD MUST BE FIXED


THROUGH TO THE CLEAT TYPES:

COARSE THREAD TEK SCREWS THROUGH


TRACK REMOVED FOR CENTERLINE OF SLOTTED HOLES
CLARITY.
FIX FLANGE OF TRACK B13510560 USE: 2no GRADE 8.8 BOLT SETS c/w
AS OPPOSITE LOCKING NUTS & WASHERS.

ENSURE BOLTED CONNECTION IS NOT


OVER-TIGHTENED AND IS FREE TO MOVE. BOLTS
MUST BE SET ON CENTERLINE OF THE CLEAT SLOT.
TRACK REMOVED FOR
CLARITY. CLEAT MUST BE SET AS FAR FROM THE SLAB EDGE
FIX FLANGE OF TRACK AS IS POSSIBLE TO IMPROVE EDGE DISTANCES FOR
CLEAT TYPE: KHC9524A AS OPPOSITE FIXINGS.
FIXING TO STEEL MEMBER
SD05 REVIEW/UPDATE 19.09.14 KPS

SD04 NEW CLEATS ADDED 26.06.13 KPS

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL
CLEAT TYPE:
B13510560 Steel Building
(AS REQUIRED BY DESIGN)
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: HIGH LOAD CLEAT AT HEAD


TRACK REMOVED FOR
CLARITY.
CONNECTION DETAIL
FIX FLANGE OF TRACK
AS OPPOSITE 16.12.09 KPS
CLEAT TYPE: KHC9528B date drg by

FIXING TO CONCRETE MEMBER scale NTS sheet A4


detail ref C.13 rev SD05
KINGSPAN STEEL BUILDING SOLUTIONS

C.13 HIGH LOAD CONNECTION - HEAVY DUTY CLEAT - HEAD C.14 HIGH LOAD CONNECTION - HEAV
ref note

ALL HIGH LOAD CLEATS ARE TO BE FIXED TO THE


PRIMARY STRUCTURE IN ACCORDANCE WITH THE
SPECIFIC FIXING SPECIFICATION SET OUT BY
KINGSPAN.

CLEAT MUST BE SET AS FAR FROM THE SLAB EDGE


AS POSSIBLE TO IMPROVE EDGE DISTANCES FOR
FIXINGS.

COARSE THREAD TEK SCREWS THROUGH


CENTERLINE OF SLOTTED HOLES

B15310560 USE:

THREAD LOW PROFILE TEK SCREWS

CLEAT TYPE
KHC9524A

SD05 REVIEW/UPDATE 19.09.14 KPS

SD04 NEW CLEATS ADDED 26.06.13 KPS

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

CLEAT TYPE:
STANDARD DETAIL
B13510560
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: HIGH LOAD CLEAT AT BASE DETAIL

CLEAT TYPE:
KHC9528B date 16.12.09 drg by KPS
scale NTS sheet A4
detail ref C.14 rev SD05
C.14 HIGH LOAD CONNECTION - HEAVY DUTY CLEAT - BASE C.15 HIGH LOAD CONNECTION - HEAVY KINGSPAN STEEL BUILDING SOLUTIONS
ref note

ALL HIGH LOAD CLEATS ARE TO BE FIXED TO THE


PRIMARY STRUCTURE IN ACCORDANCE WITH THE
SPECIFIC FIXING SPECIFICATION SET OUT BY
KINGSPAN.

FIXING CLEAT TO STUDS:

COARSE THREAD TEK SCREWS THROUGH


CENTERLINE OF SLOTTED HOLES

B13510560 USE: 2no GRADE 8.8 BOLT SETS c/w


LOCKING NUTS & WASHERS.

ENSURE BOLTED CONNECTION IS NOT


OVER-TIGHTENED AND IS FREE TO MOVE. BOLTS
MUST BE SET ON CENTERLINE OF THE CLEAT SLOT.

2 No ZED BARS POSITIONED DIRECTLY ABOVE THE


HIGH LOAD CLEAT AND THE CLEAT IS FIXED TO THE
ZEDS (THROUGH THE HEAD TRACK) USING 4 No
5.5mm, 25mm LENGTH FINE THREADED TEKS.

SD05 REVIEW/UPDATE 19.09.14 KPS

SD04 AMENDED TO SUIT FIXING 06.08.13 SBS

SD03 NEW CLEATS ADDED 26.06.13 KPS

SD02 REVIEW/UPDATE 01.05.12 KPS

SP01 STANDARD DETAIL 01.04.11 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R

CLEAT TYPE CLEAT TYPE: Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
KHC9524A B13510560
title: HIGH LOAD CLEAT AT HEAD WITH
ZED BAR CONNECTION

date 01.04.11 drg by KPS


scale NTS sheet A4
detail ref C.15 rev SD05
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

300mm LONG SECTION OF 1.2mm GAUGE TRACK IS


FITTED TO OPEN FACE OF JAMB STUD USING 3no
5.5mm COLD ROLLED TEKS THROUGH EACH FLANGE
(ONLY REQUIRED IF JAMB STUD NOT NESTED).

40mm GAP TO BE LEFT AT TOP OF TRACK.

400mm SECTION OF SLOTTED STUD FIXED TO BACK


OF TRACK SECTION USING 4no 5.5mm COLD ROLLED
TEKS THROUGH WEB.

25mm LONG 5.5mm COLD ROLLED TEKS USED TO FIX


THROUGH HEAD TRACK INTO SLOTTED STUD (AS
DETAIL A.21)

SD02 REVIEW/UPDATE 01.05.12 KPS

SP01 STANDARD DETAIL 01.04.11 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: HEAD TRACK REINFORCEMENT AT


JAMB STUD POSITION

date 01.04.11 drg by AT


scale NTS sheet A4
detail ref C.16 rev SD02
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

300mm LONG SECTION OF 1.2mm GAUGE TRACK IS


FITTED TO OPEN FACE OF JAMB STUD USING 3no
5.5mm COLD ROLLED TEKS THROUGH EACH FLANGE
(ONLY REQUIRED IF JAMB STUD NOT NESTED).

350mm SECTION OF STUD FIXED TO BACK OF TRACK


SECTION USING 4no 5.5mm COLD ROLLED TEKS
THROUGH WEB.

25mm LONG 5.5mm COLD ROLLED TEKS USED TO FIX


THROUGH BASE TRACK INTO STUD (AS DETAIL A.14)

SD02 REVIEW/UPDATE 01.05.12 KPS

SP01 STANDARD DETAIL 01.04.11 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: BASE TRACK REINFORCEMENT AT


JAMB STUD POSITION

date 01.04.11 drg by KPS


scale NTS sheet A4
detail ref C.17 rev SD02
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

RESTRAINT POST DESIGNED AND SUPPLIED BY


OTHERS.

POST TO BE OF SUITABLE DEPTH AND LENGTH TO FIT


WITHIN ZONE OF SFS AND ALLOW TOLERANCE ON
INSTALLATION. POST TO OFFER CLOSED FACES TO
AFFIX CRIPPLE STUDS.

300mm LENGTH CRIPPLE STUDS FIXED TO SIDES OF


POST USING 4no 5.5mm HOT ROLLED TEKS OR
BALLISTIC NAILS.

LINTEL TRACK FIXED TO CRIPPLE STUDS USING 2no


5.5mm COLD ROLLED TEKS THROUGH EACH FLANGE.

WINDOW SYSTEM BELOW TO ACCOMMODATE LIVE


LOAD DEFLECTION OF THE PRIMARY STRUCTURE.

SD02 REVIEW/UPDATE 01.05.12 KPS

SP01 STANDARD DETAIL 01.04.11 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: RESTRAINT POST - LINTEL CONNECTION

date 01.04.11 drg by KPS


scale NTS sheet A4
detail ref C.18 rev SD02
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

WIND MOMENT POST DESIGNED AND SUPPLIED BY


KINGSPAN STEEL BUILDING SOLUTIONS.

EACH CRIPPLE STUD FIXED TO SIDES OF POST


(80x40x5 HYBOX RHS) USING 6no 5.5mm ITW SPIT
TL32 TEKS OR EQUIVALENT AS INDICATED. SCREWS
TO OPPOSITE FACE TO BE RAISED 10MM TO AVOID
CLASHING. CRIPPLE STUDS 2mm MIN GAUGE.
2mm STUDS LINTEL TRACK FIXED TO CRIPPLE STUDS USING 1no
FIXED TO EACH 5.5mm COLD ROLLED TEK THROUGH EACH FLANGE.
SIDE OF POST
USE 4No ITW BUILDEX TAPCON II ANCHORS TO
CONCRETE THROUGH HATCH HIGHLIGHTED HOLES
ONLY.

FIXINGS TO PRIMARY STEEL THROUGH CROSS-HATCH


HIGHLIGHTED HOLES USING 4 No M12 BOLTS.

LINTEL TRACK, IF REQUIRED, TO BE SPLICED AT POST


POSITION ONLY. IF SPLICED USE FS10012 FLAT STRAP
(200MM LONG) FIXED WITH 2No 5.5mm TEKS TO EACH
STRAP REQUIRED IF TRACK
SPLICING AT POST
POSITION ONLY

SD01 STANDARD DETAIL 19.09.14 KSBS

ref revision date by

80x40x5 S355 J0H


STANDARD DETAIL
90

CONCRETE HYBOX RHS


Steel Building
130

FIXING
R65

LOCATIONS STEEL Solutions


FIXING
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
LOCATIONS
title: KINGPOST - LINTEL CONNECTION
20 20

date 27.03.14 drg by KSBS


scale NTS sheet A4
detail ref C.18A rev SD01
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

RESTRAINT POST DESIGNED AND SUPPLIED BY


OTHERS.

POST TO BE OF SUITABLE DEPTH AND LENGTH TO FIT


WITHIN ZONE OF SFS AND ALLOW TOLERANCE ON
INSTALLATION. POST TO OFFER CLOSED FACES TO
AFFIX CRIPPLE STUDS.

CRIPPLE STUDS FIXED TO SIDES OF POST USING 4no


5.5mm HOT ROLLED TEKS OR BALLISTIC NAILS.

CILL TRACK FIXED TO CRIPPLE STUDS USING 1no


5.5mm COLD ROLLED TEK THROUGH EACH FLANGE.

SD02 REVIEW/UPDATE 01.05.12 KPS

SP01 STANDARD DETAIL 01.04.11 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: RESTRAINT POST - CILL CONNECTION

date 01.04.11 drg by KPS


scale NTS sheet A4
detail ref C.19 rev SD02
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

WIND MOMENT POST DESIGNED AND SUPPLIED BY


KINGSPAN STEEL BUILDING SOLUTIONS.
STRAP REQUIRED IF
SPLICING AT POST EACH CRIPPLE STUD FIXED TO SIDES OF POST
POSITION ONLY (80x40x5 HYBOX RHS) USING 6no 5.5mm ITW SPIT
TL32 TEKS OR EQUIVALENT AS INDICATED. SCREWS
TO OPPOSITE FACE TO BE RAISED 10MM TO AVOID
2mm STUDS CLASHING. CRIPPLE STUDS 2mm MIN GAUGE.
FIXED TO EACH
CILL TRACK FIXED TO CRIPPLE STUDS USING 1no
SIDE OF POST
5.5mm COLD ROLLED TEK THROUGH EACH FLANGE.

USE 4No ITW BUILDEX TAPCON II ANCHORS TO


CONCRETE THROUGH HATCH HIGHLIGHTED HOLES
ONLY.

FIXINGS TO PRIMARY STEEL THROUGH CROSS-HATCH


HIGHLIGHTED HOLES USING 4 No M12 BOLTS.

CILL TRACK, IF REQUIRED, TO BE SPLICED AT POST


POSITION ONLY. IF SPLICED USE FS10012 FLAT STRAP
(200MM LONG) FIXED WITH 2No 5.5mm TEKS TO EACH
TRACK

20 20 SD01 STANDARD DETAIL 19.09.14 KSBS

ref revision date by

80x40x5 S355 J0H


STANDARD DETAIL
CONCRETE HYBOX RHS
Steel Building
130

R65

FIXING
LOCATIONS STEEL Solutions
FIXING
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
90

email: enquiries@kingspan.com
LOCATIONS
title: KINGPOST - CILL CONNECTION

date 27.03.14 drg by KSBS


scale NTS sheet A4
detail ref C.19A rev SD01
KINGSPAN STEEL BUILDING SOLUTIONS
.

6.4 D Series Oversail Details


Rev.
D.01 Bracket Support Dead Load (Concrete) SD04
D.01s Bracket Support Dead Load (HRS) SD03
D.02 Bracket Support Restraint Load (Concrete) SD04
D.02s Bracket Support Restraint Load (HRS) SD02
D.03 Bracket Support Dead & Restraint Load (Concrete) SD04
D.03s Bracket Support Dead & Restraint Load (HRS) SD02
D.04 Base Track Support Deadload Detail SD03
D.05 Angle Support Restraint Load SD03
D.06 Panel Joint Stud Splice Detail SD04
D.06s Panel Joint Stud Splice Detail (HRS Option) SD02
D.07 Panel to Panel Track Detail SD04
D.07s Panel Joint Panel to Panel Track Detail SD02
D.08 Kingspan Oversail Cleats SD01

These details are shown on the following pages.

87
ref note

ALL BRACKETRY AND FIXINGS ARE DESIGNED ON A


PROJECT SPECIFIC BASIS.

REFER TO DETAILS GIVEN BY KINGSPAN FOR


BRACKET ARRANGEMENTS, FIXING DETAILS AND
POSITION OF VERTICAL STUD RELATIVE TO BRACKET.

ALL CLEATS & FIXINGS TO BE INSTALLED IN


ACCORDANCE TO KINGSPAN TECHNICAL APPLICATION
DOCUMENT.

SD04 REVIEW/UPDATE 19.09.14 KPS

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: OVERSAIL FRAMING


BRACKET SUPPORT - DEADLOAD

date 16.12.09 drg by KPS


scale NTS sheet A4
detail ref D.01 rev SD04
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

ALL BRACKETRY AND FIXINGS ARE DESIGNED ON A


PROJECT SPECIFIC BASIS.

REFER TO DETAILS GIVEN BY KINGSPAN FOR


BRACKET ARRANGEMENTS, FIXING DETAILS AND
POSITION OF VERTICAL STUD RELATIVE TO BRACKET.

ALL CLEATS & FIXINGS TO BE INSTALLED IN


ACCORDANCE TO KINGSPAN TECHNICAL APPLICATION
DOCUMENT.

SD03 REVIEW/UPDATE 19.09.14 KPS

SD02 KINGSPAN STANDARD CLEATS ADDED 18/09/2014 KSBS

SD01 FIRST ISSUE 01.05.12 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: OVERSAIL FRAMING


BRACKET SUPPORT - DEADLOAD
(HRS OPTION)
date 01.05.12 drg by KPS
scale NTS sheet A4
detail ref D.01S rev SD03
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

ALL BRACKETRY AND FIXINGS ARE DESIGNED ON A


PROJECT SPECIFIC BASIS.

REFER TO DETAILS GIVEN BY KINGSPAN FOR


BRACKET ARRANGEMENTS, FIXING DETAILS AND
POSITION OF VERTICAL STUD RELATIVE TO
BRACKET.

ALL CLEATS & FIXINGS TO BE INSTALLED IN


ACCORDANCE TO KINGSPAN TECHNICAL
APPLICATION DOCUMENT.

SD04 KINGSPAN STANDARD CLEATS ADDED 19.09.14 KSBS

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: OVERSAIL FRAMING


BRACKET SUPPORT - RESTRAINT LOAD

date 16.12.09 drg by KPS


scale NTS sheet A4
detail ref D.02 rev SD04
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

ALL BRACKETRY AND FIXINGS ARE DESIGNED ON A


PROJECT SPECIFIC BASIS.

REFER TO DETAILS GIVEN BY KINGSPAN FOR


BRACKET ARRANGEMENTS, FIXING DETAILS AND
POSITION OF VERTICAL STUD RELATIVE TO
BRACKET.

ALL CLEATS & FIXINGS TO BE INSTALLED IN


ACCORDANCE TO KINGSPAN TECHNICAL
APPLICATION DOCUMENT.

SD02 KINGSPAN STANDARD CLEATS ADDED 19.09.14 KSBS

SD01 FIRST ISSUE 01.05.12 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: OVERSAIL FRAMING


BRACKET SUPPORT - RESTRAINT LOAD
(HRS OPTION)
date 01.05.12 drg by KPS
scale NTS sheet A4
detail ref D.02S rev SD02
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

ALL BRACKETRY AND FIXINGS ARE DESIGNED ON A


PROJECT SPECIFIC BASIS.

REFER TO DETAILS GIVEN BY KINGSPAN FOR


BRACKET ARRANGEMENTS, FIXING DETAILS AND
POSITION OF VERTICAL STUD RELATIVE TO BRACKET.

ALL CLEATS & FIXINGS TO BE INSTALLED IN


ACCORDANCE TO KINGSPAN TECHNICAL APPLICATION
DOCUMENT.

SD04 KINGSPAN STANDARD CLEATS ADDED 19.09.14 KSBS

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: OVERSAIL FRAMING


BRACKET SUPPORT
RESTRAINT & DEAD LOAD
date 16.12.09 drg by KPS
scale NTS sheet A4
detail ref D.03 rev SD04
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

ALL BRACKETRY AND FIXINGS ARE DESIGNED ON A


PROJECT SPECIFIC BASIS.

REFER TO DETAILS GIVEN BY KINGSPAN FOR


BRACKET ARRANGEMENTS, FIXING DETAILS AND
POSITION OF VERTICAL STUD RELATIVE TO BRACKET.

ALL CLEATS & FIXINGS TO BE INSTALLED IN


ACCORDANCE TO KINGSPAN TECHNICAL APPLICATION
DOCUMENT.

SD02 KINGSPAN STANDARD CLEATS ADDED 19.09.14 KSBS

SD01 FIRST ISSUE 01.05.12 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: OVERSAIL FRAMING


BRACKET SUPPORT
RESTRAINT & DEAD LOAD (HRS OPTION)
date 01.05.12 drg by KPS
scale NTS sheet A4
detail ref D.03S rev SD02
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

ALL BRACKETRY AND FIXINGS ARE DESIGNED ON A


PROJECT SPECIFIC BASIS.

'U' TRACK IS FIXED TO SUPPORT ANGLE IN


ACCORDANCE WITH A.04. VERTICAL 'C' SECTIONS
ARE PLACED IN ACCORDANCE WITH THE
SPECIFICATION AND DETAIL A.13.

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: BASE TRACK SUPPORT ANGLE


DEADLOAD

date 16.12.09 drg by KPS


D.04 BRACKET SUPPORT - DEAD LOAD DETAIL scale NTS sheet A4
detail ref D.04 rev SD03
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

ALL BRACKETRY AND FIXINGS ARE DESIGNED ON A


PROJECT SPECIFIC BASIS.

REFER TO DETAILS GIVEN BY KINGSPAN FOR


BRACKET ARRANGEMENTS, FIXING DETAILS AND
POSITION OF VERTICAL STUD RELATIVE TO
BRACKET.

ALL CLEATS & FIXINGS TO BE INSTALLED IN


ACCORDANCE WITH THE MANUFACTURERS
RECOmmENDATIONS.

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: OVERSAIL FRAMING


ANGLE SUPPORT RESTRAINT LOAD

date 16.12.09 drg by KPS


scale NTS sheet A4
detail ref D.05 rev SD03
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

ALL BRACKETRY AND FIXINGS ARE DESIGNED ON A


PROJECT SPECIFIC BASIS.

2mm GAUGE 'U' SECTION TRACK MINIMUM 600mm IN


LENGTH FIXED ON CENTRELINE OF JOINT (300mm
EACH SIDE OF JOINT LINE) WITH FIXINGS AS
SPECIFIED BY KINGSPAN.

DETAIL MAY NOT BE USED WITHOUT SPECIFIC


REFERENCE TO KINGSPAN.

ALL CLEATS & FIXINGS TO BE INSTALLED IN


ACCORDANCE TO KINGSPAN TECHNICAL
APPLICATION DOCUMENT.

SD04 KINGSPAN STANDARD CLEATS ADDED 19.09.14 KSBS

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: OVERSAIL FRAMING


PANEL JOINT - STUD SPLICE

date 16.12.09 drg by KPS


scale NTS sheet A4
detail ref D.06 rev SD04
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

ALL BRACKETRY AND FIXINGS ARE DESIGNED ON A


PROJECT SPECIFIC BASIS.

REFER TO DETAILS GIVEN BY KINGSPAN FOR


BRACKET ARRANGEMENTS, FIXING DETAILS AND
POSITION OF VERTICAL STUD RELATIVE TO
BRACKET.

ALL CLEATS & FIXINGS TO BE INSTALLED IN


ACCORDANCE TO KINGSPAN TECHNICAL
APPLICATION DOCUMENT.

SD02 KINGSPAN STANDARD CLEATS ADDED 19.09.14 KSBS

SD01 FIRST ISSUE 01.05.12 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: OVERSAIL FRAMING


PANEL JOINT - STUD SPLICE
(HRS OPTION)
date 01.05.12 drg by KPS
scale NTS sheet A4
detail ref D.06S rev SD02
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

ALL BRACKETRY AND FIXINGS ARE DESIGNED ON A


PROJECT SPECIFIC BASIS.

'U' SECTION TRACK USED TO CAP LOWER PANEL


AND FIXED IN ACCORDANCE WITH A.13. UPPER 'U'
SECTION FIXED DOWN THROUGH WEB INTO LOWER
TRACK WITH FIXINGS AT 300mm STAGGERED CTS.
STUDS ABOVE FIXED IN ACCORDANCE WITH A.13.

ALL CLEATS & FIXINGS TO BE INSTALLED IN


ACCORDANCE TO KINGSPAN TECHNICAL
APPLICATION DOCUMENT.

SD04 KINGSPAN STANDARD CLEATS ADDED 19.09.14 KSBS

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: OVERSAIL FRAMING


PANEL JOINT
PANEL TO PANEL TRACK
date 16.12.09 drg by KPS
scale NTS sheet A4
detail ref D.07 rev SD04
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

ALL BRACKETRY AND FIXINGS ARE DESIGNED ON A


PROJECT SPECIFIC BASIS.

REFER TO DETAILS GIVEN BY KINGSPAN FOR


BRACKET ARRANGEMENTS, FIXING DETAILS AND
POSITION OF VERTICAL STUD RELATIVE TO
BRACKET.

ALL CLEATS & FIXINGS TO BE INSTALLED IN


ACCORDANCE WITH THE MANUFACTURERS
GUIDANCE.

ALL CLEATS & FIXINGS TO BE INSTALLED IN


ACCORDANCE TO KINGSPAN TECHNICAL
APPLICATION DOCUMENT.

SD02 KINGSPAN STANDARD CLEATS ADDED 19.09.14 KSBS

SD01 FIRST ISSUE 01.05.12 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: OVERSAIL FRAMING


PANEL JOINT
PANEL TO PANEL TRACK
date 01.05.12 drg by KPS
scale NTS sheet A4
detail ref D.07S rev SD02
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

CLEAT REF L(mm) CLEAT REF L(mm)


REFER TO DETAILS GIVEN BY KINGSPAN FOR
KWC 9524-100 100 KWC 14028-100 100
BRACKET ARRANGEMENTS, FIXING DETAILS AND
KWC 9524-125 125 KWC 14028-125 125
POSITION OF VERTICAL STUD RELATIVE TO
KWC 9524-150 150 KWC 14028-150 150
BRACKET.
KWC 9524-175 175 KWC 14028-175 175
KWC 9524-200 200 KWC 14028-200 200 ALL CLEATS & FIXINGS TO BE INSTALLED IN
KWC 9524-225 225 KWC 14028-225 225 ACCORDANCE WITH KINGSPAN GUIDANCE DETAILS.
KWC 9524-250 250 KWC 14028-250 250
KWC 9524-275 275 KWC 14028-275 275
KWC 9524-300 300 KWC 14028-300 300
2.4mm Thk. 2.8mm Thk.

CLEAT REF L(mm) CLEAT REF L(mm)


KWC 20040-100 100 KWC 14040-100 100
KWC 20040-125 125 KWC 14040-125 125
KWC 20040-150 150 KWC 14040-150 150
KWC 20040-175 175 KWC 14040-175 175
KWC 20040-200 200 KWC 14040-200 200
KWC 20040-225 225 KWC 14040-225 225 SD01 FIRST ISSUE 19.09.14 KSBS

KWC 20040-250 250 KWC 14040-250 250 ref revision date by

KWC 20040-275 275 KWC 14040-275 275


KWC 20040-300 300 KWC 14040-300 300 STANDARD DETAIL
4.0mm Thk. 4.0mm Thk.

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: OVERSAIL FRAMING


KINGSPAN OVERSAIL CLEATS

date 15.09.14 drg by KPS


scale NTS sheet A4
detail ref D08 rev SD01
KINGSPAN STEEL BUILDING SOLUTIONS
6.5 E Series Boarding Details
Rev.
E.01 External Board Typical Set Out SD03
E.02 External Board Detail Across Slab Edge SD03

These details are shown on the following pages.

101
ref note

STUD BOARD SPECIFICATION BY OTHERS.

ALL BOARD FIXINGS SHOULD BE IN ACCORDANCE


WITH THE MANUFACTURER'S RECOMMENDATIONS
30 BUT SHOULD NOT BE ANY LESS ONEROUS THAN

300
BOARDING JOINT INDICATED IN THIS DRAWING.

600
VERTICAL STUDS ARE PROVIDED IN MODULES OF 200,
300, 400 OR 600mm TO SUIT 2400x1200mm BOARDS.

BOARDS ARE TO BE STAGGERED IN A 'BRICK BOND'


BOARDING FIXINGS LAYOUT AS SHOWN.

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: EXTERNAL BOARD TYPICAL SET OUT

date 16.12.09 drg by KPS


scale NTS sheet A4
detail ref E.01 rev SD03
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

BOARD SPECIFICATION BY OTHERS.

ALL BOARD FIXINGS SHOULD BE IN ACCORDANCE


WITH THE MANUFACTURER'S RECOmmENDATIONS
BUT SHOULD NOT BE ANY LESS ONEROUS THAN
INDICATED IN THIS DRAWING.
MAX 10mm
WORKMANSHIP TOLERNACE
VERTICAL STUDS ARE PROVIDED IN MODULES OF 200,
300, 400 OR 600mm TO SUIT 2400x1200mm BOARDS.

DEFLECTION GAP ABOVE STUDS MUST BE LEFT FREE


OF FIXINGS AND OTHER OBSTRUCTIONS.

25mm
MAX LIVE LOAD DEFLECTION

10mm
BOARD TO FIXING EDGE DISTANCE

HEAD TRACK LEG


SD03 REVIEW/UPDATE 01.05.12 KPS

67mm
SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS


25mm
ref revision date by
EXPANSION JOINT

STANDARD DETAIL

Steel Building
40mm MIN.
FROM TRACK LEG TO FIXING Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
65mm Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
BOARD TO FIXING EDGE DISTANCE
TO AVOID HEAD TRACK LEG
title: EXTERNAL BOARDING ACROSS
SLAB EDGE

date 16.12.09 drg by KPS


scale NTS sheet A4
detail ref E.02 rev SD03
KINGSPAN STEEL BUILDING SOLUTIONS
6.6 F Series Finishes Details
Rev.
F.01 Finishes Condition Generic Infill Masonry Layout Showing Brick Tie Studs SD03

These details are shown on the following pages.

104
ref note

ADDITIONAL BRICK TIE STUDS REQUIRED AT MAX


225mm FROM JAMB STUDS. NOMINALLY PLACED AT
150mm ON KINGSPAN DRAWINGS.

ADDITIONAL STUDS MAY ALSO BE REQUIRED FOR


OTHER CLADDING TYPES. PLEASE ADVISE OF ANY
SPECIFIC REQUIREMENTS PRIOR TO DESIGN.

150

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

= ADDITIONAL BRICK TIE STUD title: GENERIC INFILL MASONRY LAYOUT


SHOWING BRICK TIE STUDS

date 16.12.09 drg by KPS


scale NTS sheet A4
detail ref F.01 rev SD03
KINGSPAN STEEL BUILDING SOLUTIONS
6.7 G Series Building Details
Rev.
G.01 Party Wall Type 1 Detail SD03
G.02 Party Wall Type 2 Detail SD03
G.03 Brick Movement Joint SD01

These details are shown on the following pages.

106
ref note

DRYLINING WALL CONSTRUCTION BY OTHERS


PENETRATES EXTERNAL WALL.

DIMENSION 'A' TO BE PROVIDED BY ARCHITECT.

BOTH HEAD & BASE TRACKS ARE CUT TO PROVIDE


CLEAR ACCESS FOR DRYLINING WALL. EXTERNAL
SHEATHING BOARD FIXED TO SFS WALL WITH
BRIDGING PIECE FITTED AFTER COMPLETION OF
DRYLINING WALL.

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

= = SP01

ref
SPECIFICATION

revision
16.12.09

date
KPS

by

STANDARD DETAIL
DIM 'A'
Steel Building
Solutions
DRYLINING WALL CONSTRUCTION BY OTHERS PENETRATES EXTERNAL
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
R

email: enquiries@kingspan.com

title: PARTY WALL TYPE 1 DETAIL

date 16.12.09 drg by KPS


scale NTS sheet A4
detail ref G.01 rev SD03
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

DRYLINING WALL CONSTRUCTION BY OTHERS IS


INDEPENDANT OF THE EXTERNAL WALL.

EXTERNAL SHEATHING BOARD FIXED TO SFS WALL AS


MANUFACTURERS REQUIREMENTS.

NO ADDITIONAL SETTING OUT OR PROVISION OF


ADDITIONAL SFS STUDS IS REQUIRED.

SD03 REVIEW/UPDATE 01.05.12 KPS

SD02 STANDARD DETAIL 01.04.11 KPS

SP01 SPECIFICATION 16.12.09 KPS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: PARTY WALL TYPE 2 DETAIL

date 16.12.09 drg by KPS


scale NTS sheet A4
detail ref G.02 rev SD03
KINGSPAN STEEL BUILDING SOLUTIONS
ref note

*
*
*

AS PER PROJECT
REQUIREMENTS 225mm max.
SFS ZONE
BUILD UP OF EXTERNAL LEAF
BY OTHERS

SD01 SPECIFICATION 04.11.14 KSBS

ref revision date by

STANDARD DETAIL

Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com

title: BRICK MOVEMENT JOINT - SFS DETAILS

date 04.11.14 drg by KSBS


scale NTS sheet A4
detail ref G03 rev SD01
KINGSPAN STEEL BUILDING SOLUTIONS
7.3 Insulated Render
7 CLADDING
TREATMENTS Lightweight insulated render systems can be fully
supported by the SFS. There are generally two
types of system which vary in their detail and
7.1 Introduction application between manufacturers; direct applied
The typical cladding build-ups shown in this & cavity systems.
section are for guidance only. The project
architect or cladding contractor is to maintain Direct Applied Systems
responsibility for the overall performance of the When the render build up is applied either
wall and their detailing should be deferred to in all adhesively or mechanically to the SFS, there are
instances. no special requirements to consider. A typical wall
build up is given below;
7.2 Masonry

Typical Wall Build Up


SFS design with masonry outer leaf cladding is
generally formed as shown below;

Cavity Systems
Where a drainage/ventilation cavity is required,
the cavity is usually placed between the sheathing
board and the insulation by use of vertical top hat
spacers. Further guidance should be sought from
All masonry must be dead loaded to a suitable the render system manufacturer.
support (slab edge angle or ground slab) as
the SFS is designed to withstand horizontal
loads only in this case.

Brick Tie Studs


All fixings of brick tie channels are to be fixed
back to the SFS through the insulation. In
instances around structural openings, an
additional stud is provided at a nominal 150mm
from the line of the opening to accept the channel
as Detail F.01.

115
7.6 Metal Rainscreen
7.4 Terracotta Rainscreen
Lightweight metal rainscreen systems may be
Terracotta tile systems may be supported from an supported from an SFS system. There are
SFS system. The dead weight and loadings of the typically two main types of support to a tile based
chosen system must be communicated to system; horizontal support and vertical systems.
Kingspan Steel Building Solutions engineers to
check the adequacy of a given stud arrangement. Horizontal Systems
There are typically two main types of support to a Where the interfacing rails for the rainscreen are
tile based system; horizontal and vertical systems. fixed horizontally to the SFS, the load is evenly
distributed across the frame. This requires no
Horizontal Systems special constructions within the SFS.
Where the interfacing rails for the terracotta are
fixed horizontally to the SFS, the load is evenly Vertical Systems
distributed across the frame. This requires no Where the cladding rails span vertically, there is
special constructions within the SFS. may either be a sub-system of horizontally
spanning rails to distribute the loads in the SFS or
Vertical Systems the brackets may be directly fixed back to the
Where the cladding rails span vertically, there is SFS. In the latter case, there may be specific
may either be a sub-system of horizontally setting out requirements for the SFS in order to
spanning rails to distribute the loads in the SFS or guarantee studs in the desired locations. These
the brackets may be directly fixed back to the need to be specifically identified to Kingspan Steel
SFS. In the latter case, there may be specific Building Solutions prior to design.
setting out requirements for the SFS in order to
guarantee studs in the desired locations. These
need to be specifically identified to Kingspan Steel
Building Solutions prior to design.

7.5 Timber Rainscreen 7.7 Stone Panels


Timber rainscreen systems can be directly applied
Stone panels must be dead loaded to a suitable
to an SFS system and requires no special
element to transfer all dead weight into the
constructions. Horizontal timber battens are laid
primary structure. The SFS is designed to
directly onto the SFS or the carrier board with
withstand horizontal forces only in this situation.
vertical timbers creating a lattice frame for the
The setting out and direction of span of the stone
finished boards to be fixed into.
is critical to the performance of the SFS and must
be reviewed by Kingspan Steel Building Solutions
engineers.

116
8 COSHH & TECHNICAL DATASHEETS
8.1 General Specification Notes

PRODUCTS: Steel Framing System U Track and C Stud cold formed steel galvanised profiles

SUPPLIER:
Kingspan Steel Building Solutions, Pleck Road, Walsall, WS2 9ES
Tel; +44 (0) 1944 712 000
www.kingspanprofiles.com

Products
Cold rolled components are manufactured from Service slots can be provided in studs when
pre-hot dipped galvanised steel, Z275 coating, requested and if deemed acceptable by Kingspan
guaranteed yield strength 390 N/mm. All studs, Steel Building Solutions Design Department.
joists, tracks and accessories shall be of a type, Track members shall be securely anchored to the
size, gauge and spacing determined by structural supporting structure as shown on the drawings.
calculation and as shown on the drawings, and Complete, uniform and level bearing support shall
shall be supplied by Kingspan Steel Building be provided to upper and lower tracks. Abutting
Solutions. Unless stated otherwise in the lengths of track shall be securely anchored to a
calculations, all structural members are designed common structural element and spliced, all as
in accordance with UK codes of practice. determined by structural calculations. Studs shall
be plumbed, aligned and securely
Procurement attached/located within upper and lower tracks.
It is the installers responsibility to produce a Framing of wall openings shall include headers,
cutting list and order Kingspan Steel Building lintels and supporting studs as shown on the
Solutions materials. This should be co-ordinated drawings. Temporary bracing shall be provided
to suit the desired construction programme. where required until completion of erection. The
erection contractor is responsible for the
Drawing Approval temporary stability of the structure during
All drawings must be approved by the main construction.
contract Engineer and project Architect prior to
construction works. External Walls
Insulation should be provided over the external
Erection of Components face of the stud walling that is sufficiently robust to
All systems are constructed on-site and must be remain in place during and post construction, and
installed to British Standard BS5950, BS8000 and should have adequate thermal resistance to
NSSS (National Structural Steelwork prevent cold bridging and interstitial condensation.
Specification). Liability for the quality and Insulation should be fixed in accordance with
accuracy of the installation rests with the manufacturers instructions. Consideration should
Contractor and not Kingspan Steel Building be given to joints in insulation boards and the
Solutions. Care must be taken when site cutting repair of damage to prevent ingress e.g. taping of
components square where they are to be used in joints or provision of a breather membrane.
right angled connections and all cut edges should Internal linings should be fixed in accordance with
be protected. Fixing of components shall be with the manufacturers instructions and selected to
self-tapping screws or otherwise by design. Screw achieve the specified performance for fire,
type and size shall be as typical details or to a thermal, and acoustic requirements. Where
project specific design. All screw fixings must be masonry cladding forms the external envelope, it
installed perpendicular to the surface wherever should be tied back to the Kingspan Steel Building
possible. All bolt fixings are to be Grade 8.8. No Solutions studs using stainless steel wall ties and
holes are to be cut or formed in Kingspan Steel continuous channels fixed with standoff screws.
Building Solutions SFS without prior reference to Additional studs are to be fitted at all jambs to
Kingspan Steel Building Solutions. provide support for wall ties.

117
8.2 COSHH Datasheet

PRODUCTS:
Steel Framing System U Track and C Stud cold formed steel galvanised profiles

SUPPLIER:
Kingspan Steel Building Solutions, Pleck Road, Walsall, WS2 9ES
Tel; +44 (0) 1944 712 000
http://www.kingspanprofiles.com

USE DISPOSAL OF PRODUCT


Steel Sections form internal/external, structural/non- The disposal of steel, panel or other associated waste/scrap
structural walls, floors and ceilings. They may be supplied must be carried out by an authorised and qualified disposal
partially or fully assembled. agent and in any case at a site suitable for the re-cycling of the
steel section, or an authorised land fill site. The sharp edges
TYPICAL COMPOSITION could present a danger and must be kept out of reach.
Steel panels are assembled from cold rolled steel sections
manufactured from hot dip, zinc-coated / iron zinc coated slit HEALTH HAZARDS, PRECAUTIONS & FIRST AID
steel coil to BS EN 10143:2006. The profiles are rolled in Steel sections are designed to be structurally sound according
accordance with the specification for cold rolled steel profiles to each application and are structurally capable in the
to BS EN 10162:2003. Cold rolled profiles are manufactured assembled designed condition only. The integrity of the
as suitable for use in the specification of galvanised steel stud assembled panel/module must not be reduced by
and track partitions and linings using screw fixed gypsum unauthorised dismantling and/or removal of material whether
walling board to BS 7364:1990 or other boards depending on steel, board or fastenings. Panel/module assemblies are not
the application. designed to support any structure other than the finished
product so must neither be used, nor relied upon, as supports
Boards, Fastenings and Fittings may be of various proprietary during storage or assembly.
materials each of which will have its own safety information
sheet supplied by the manufacturer. It is the responsibility of all personnel working on or with the
panels and modules to support themselves safely and, if
STEEL necessary, form an independent support system.
All steel is hot dip iron zinc galvanised to a coating thickness
typically of 275g/m2. HEALTH HAZARD EYE CONTACT
Extreme care must be taken when releasing and breaking
HANDLING OF PRODUCT open bundle strapping. When bundle strapping is cut tension is
Steel sections are either handled individually or banded into released, causing the strapping to spring freely from the
bundles for ease of transportation depending on size, shape bundle which can result in eye injury. The use of tools
and weight. (especially power cutting tools) on steel sections generates
Steel sections are loaded onto transport in a way that enables potentially hazardous shavings and sparks.
easier mechanical off-loading.
Precautions
Kingspan provide guidance on handling methods to the Packs and bundles must be opened whilst on the ground to
contractor as part of the installation training course. avoid the possibility of their contents falling over and causing
injury. A number of protective measures are also
Any distortion or damage to the sections must be avoided recommended:
during handling as this could affect structural integrity. 1. Safety footwear should be worn.
2. Suitable eye protection should be used (a) when cutting
It is important that sufficient space is available for moving the strapping; (b) when cutting the profile and c) when
sections from the unloading point to any intermediate storage using tools of any sort.
area and/or the final assembly location. 3. Safety gloves capable of protecting the skin form steel
shavings and sharp edges should be worn.
Where banded sections require lifting by hoists and cranes 4. Strapping should be restrained from springing freely
then ropes and slings should be used together with a suitable whilst being cut.
trailing tie to stop uncontrolled swinging. Bundles should
never be lifted by their bands. First Aid
In the event of eye injury, cuts or abrasions, seek immediate
STORAGE OF PRODUCT medical attention. It is also recommended that if a cut is
All steel sections can be stacked either flat or on edge and received requiring medical or first aid attention, professional
must be supported along their length and width. A number of advice should be attained regarding the possible need for a
recommendations are made: Tetanus injection.
i) All sections should be stored in clean, dry conditions,
protected from inclement weather.
ii) No sections should be stored next to or in contact
with dry cement, lime, plaster or mortar.
iii) Full bundles of sections should not be stacked more
than two high with each bundle adequately separated by
timber batons of equal sizes placed at regular intervals along
the length of the pack.

118
HEALTH HAZARD SKIN CONTACT: protect hands and exposed skin with a barrier cream or
Lacerations of the skin can occur from sharp corners and suitable gloves.
edges or when breaking open strapping. Foot injuries could First Aid:
also be sustained when walking over discarded steel debris on In the event of skin irritation or injury, immediate medical
site (e.g. re-cut edges of sections). Steel shavings and sparks attention must be sought by an appropriately qualified person.
are produced when using tools (particularly power tools).
Precautions: HEALTH HAZARD - INHALATION:
1. Hand and Power tools should be used only by those Steel sections at atmospheric temperatures do not emit any
wearing suitable protection. fumes or gasses.
2. Lifting recommended techniques must be adhered to
and manual lifting should be limited to acceptable PRECAUTIONS:
weights. Never lift any packs that are not within the (As stated above).
method limits. Health Hazard Ingestion:
3. Loading and Unpacking suitable gloves and protective (not applicable)
clothing should be worn. Health Hazard Exposure limits:
4. General Handling persons with skin problems, grazes (not applicable)
and those known to be sensitive to mineral oils should Health Hazard Fire and Explosion hazards:
(not applicable)

FURTHER INFORMATION:
Please contact the Kingspan Steel Building Solutions Technical Team on +44 (0)1944 712000.

This information is provided in good faith on the assumption that the person carrying out the task of using the product is
experienced and/or has been fully trained in the handling and use of the particular product and application.

The reader must be satisfied that they (or the person carrying out the application) are suitably responsible and that these
recommendations have been thoroughly read and understood by that person.

Kingspan Steel Building Solutions does not accept responsibility for any claims of consequential loss or injury to the user or
third party if the recommendations of this safety sheet are not adhered to.

119
9 SUPPORT SERVICES
Kingspan Steel Building Solutions offers a range of design and supply services operating from a number of
sites in the UK. To serve our customers with the maximum efficiency, we would be grateful if you could direct
your question to the following contacts:

9.1 Material Ordering & Production Enquiries


Customer Services
Kingspan Steel Building Solutions
Pleck Road
Walsall
WS2 9ES
Telephone: +44 (0)1922 728 312
Fax: +44 (0)1922 644 460
Email: shalina.begum@kingspan.com

9.2 Technical Enquiries


SFS Technical Manager
Kingspan Steel Building Solutions
2 & 3 Progress Works
Heath Mill Lane
(Access Via Bromley Street)
Birmingham
B9 4AL
Telephone: +44 (0)121 753 7050
Fax: +44 (0)121 753 5187

9.3 Sales & Commercial Enquiries


Gaynor Phillips
Project Co-ordinator
Kingspan Steel Building Solutions
2 & 3 Progress Works
Heath Mill Lane
(Access Via Bromley Street)
Birmingham
B9 4AL
Telephone: +44 (0)121 753 7071
Fax: +44 (0)121 753 5187

9.4 Site Support Enquiries


Contracts Manager
Kingspan Steel Building Solutions
2 & 3 Progress Works
Heath Mill Lane
(Access Via Bromley Street)
Birmingham
B9 4AL
Telephone: +44 (0)121 753 7050
Fax: +44 (0)121 753 5187

120
Kingspan Steel Building Solutions
2 & 3 Progress Works Heath Mill Lane (Access via Bromley Street) Birmingham B9 4AL
T: +44(0)121 753 7050 F: +44(0)121 753 5187 www.kingspanpanels.co.uk/sbs
Care has been taken to ensure that the contents of this publication are accurate, but Kingspan Limited and its subsidiary
companies do not accept responsibility for errors or for information that is found to be misleading. Suggestions for, or
description of, the end use or application of products or methods of working are for information only and Kingspan Limited
and its subsidiaries accept no liability in respect thereof.

You might also like