You are on page 1of 6

Compressive stress of concrete, fck 20 N/mm2

Load , P 974.9 kN
Factored Load , Pu 1462.28 kN
SBC of Soil , q max 250 kN/m2
Size of Column or Pedestal b 850 mm
d 850 mm
Limiting bearing stress , fbr max =
0.45fck(A1/A2) 6502.5 kN > Pu 1462.28
Area of the footing required 4.289 m2

Assumed , L 1600 mm 1600


B 2800 mm 2681
tan 1.35
Depth of Footing, D=((L-b)/2)*tan 506 mm
Hence Provide the Depth of footing 800 mm
effective depth of footing, 730 mm

DEPTH OF FOUNDATION
As per Rankines formula
Unit weight of soil taken, 1.9 T/m2
Angle of cohesion, 40 deg

D = (qa/)*((1-sin)/(1+sin))^2
((1-sin)/(1+sin))^2 0.05
(qa/) 13
depth 0.622 m
Provide Depth 1.0 m

Check for Base pressure


Unit wt of concrete 25 kN/m3
Unit wt of Soil 18 kN/m3
Actual soil pressure, qmax 241.2 kN/m2 < q max 250 kN/m2
safe

Size of Pedastal b 850 mm


d 850 mm

Proved Nominal Reinforcement in order to account for temperature and shrinkage effects
face1 - Reinforcement in both ways 1600 X 800
Ast Provided - 0.12% 1401.6 mm2
Provide dia of bar 8 mm
Spacing of the bar 123.63 mm Y8mm @ 110 c/c
face2 - Reinforcement in both ways 2800 X 800
Ast Provided - 0.12% 2452.8 mm2
Provide dia of bar 8 mm
Spacing of the bar 119.67 mm Y8mm @ 110 c/c
40000
850 4500
4500
GL

1000

800 53
FL
2800

2800

5.248
2.8 3.28 9.184
850 1600 2.5 3.28 8.2
1.5 3.28 4.92
850 1.5 3.28 4.92
1.5 3.28 4.92
1.5 3.28 4.92

e effects
5500

-0.984

You might also like