SOFTWARE DESCRIPTION
Software:

CIFA_rps2.0

Hardware:

Bosch Rexroth RC 2-2/21

Description:

CPU managing of RPS analogue electronic of Magnum open circuit


Gestione a Microprocessore dellelettronica analogica RPS del Magnum circuito
aperto

Cifa_rps2.0
CIFA SpA 29/10/2012
Via Stati Uniti d'America, 26
20030 - Senago (Milano)

Contents

1. Functions (funzioni)
1.1. Pumping / Suction (pompaggio / aspirazione)

2. Hardware
2.1. Input / Output description (ingressi / uscite)
2.2. Pin-out

3. Software
3.1. Process data (dati di processo)
3.2. Parameters (parametri)
3.3. Diagnostic (diagnostica)

4. Setup

Cifa_rps2.0
CIFA SpA 29/10/2012
Via Stati Uniti d'America, 26
20030 - Senago (Milano)

1. Functions (funzioni)
This software manage the concrete flow quantity of the pumping unit of a Magnum open circuit machine . The SW
replace the normal functions of the RPS analogue electronic . At the standard functions of pumping and suction,
the Cifa_rps2.0 adds some small features like the possibility to set the potentiometers the timer time, the min/max
current of the proportional valve.

Il software gestisce la portata di calcestruzzo del gruppo pompante del Magnum a circuito aperto. Il SW sostituisce
le normali funzioni del RPS analogico. Oltre alle funzioni standard di pompa/aspira il Cifa_rps2.0 aggiunge delle
piccole funzioni come ad esempio la possibilit di settare i potenziometri, il timer, le correnti della valvola
proporzionale.

1.1. Pumping / Suction ( pompaggio / aspirazione )

By selecting PUMP (or SUNCTION) and/or not LOCAL on the machine panel, the volume of the pumping unit is
determinate by the local or remote potentiometer. The S-Valve speed is determinate by the S-VALVE
potentiometer.

Selezionando pompa( o aspira) e (o non ) locale il volume pompato sar determinato dal potenziometro locale
o remoto. La velocit di scambio della valvola S viene determinata dall apposito potenziometro.

Cifa_rps2.0
CIFA SpA 29/10/2012
Via Stati Uniti d'America, 26
20030 - Senago (Milano)

2. Hardware
The system is made by a RC2-2/21 control unit, two end-stroke micro/switch for the pumping cylinders, two
potentiometers for the RPS and one for the S-valve speed

Il sistema composto da una scheda RC2-2/21, due finecorsa sui cilindri pompanti, due potenziometri per il
controllo del RPS e uno per il controllo dello scambio valvola S

2.1. Input / Output description (Descrizione degli ingressi/uscite)

End_stroke sensor: a voltage switch signal (0 24 V).

Finecorsa : sensore induttivo (ingresso digitale) (0-24V)

Potentiomer: analog voltage input for the pumping unit speed.

Potenziometro: Igresso analogico RPS

Potentiomer: analog voltage input for the S-valve switching speed.

Potenziometro: Ingresso analogico scambio valvola-S

Pumping / Suction: double switch input

Pompa / aspira: doppio ingresso digitale


Cifa_rps2.0
CIFA SpA 29/10/2012
Via Stati Uniti d'America, 26
20030 - Senago (Milano)

Local: Switch imput

Locale : Ingresso digitale

2.2. Pin-out

Description PIN number


Battery 24 V with emergency switch 1, 27, 41, 42
Ground 2, 28
I-LOCAL (I-LOCALE) 44
I POTI RPS (I-POTENZIOMETRO RPS) 36;35;38
I POTI S VALVE (I-POTENZIOMETRO S-VALVE) 47;46;49
I-LIMIT SWITCH1 (I-FINECORSA 1) 37
I-POTI RPS REMOTE (I-POTI RPS REMOTO) 48
I-LIMIT SWITCH2 (I-FINECORSA 2) 11
I-PUMPING/SUNCTION(I-POMPAGGIO/ASPIRAZIONE) 10
O-RPS VALVE (U-VALVOLA RPS) 31
ECU-OK LED / LED SCHEDA-OK 29
ERROR LED / LED ERRORI 15
Diagnostic connector 24, 50, 51,52

Cifa_rps2.0
CIFA SpA 29/10/2012
Via Stati Uniti d'America, 26
20030 - Senago (Milano)

3. Software
It is possible to check the software working, to vary some parameters for the different functions and see eventual
errors during the machine working.

3.1. Process data


Menu 1:
Process data Units Description
1 potirps % Percent value of rps potentiometer (percentuale di potenziometro rps)
2 potisvalve % Value of svalve potentiomer (percentuale di potenziometro svalve)
3 finecorsa1 - Pumping unit limit switch cylinder 1 (finecorsa cilindro1)
4 finecorsa2 - Pumping unit limit switch cylinder 2 (finecorsa cilindro2)
5 pompaggio - Pumping switch input (ingresso interruttore pompa)
6 rps_Valve mA Current to rhe RPS valve (corrente alla valvola rps)
7 locale - Input local switch on (input locale)
8 Rpsrem % Remote RPS poti ( potenziometro RPS remoto)

Cifa_rps2.0
CIFA SpA 29/10/2012
Via Stati Uniti d'America, 26
20030 - Senago (Milano)

3.2. Parameters
Menu 1:

1 Settings
Parameter Units Default Range Description Level
1 potirps -- --- Set the min/max values of local RPS potentiometer -
Tara I valori min/max del potenziometro RPS locale
2 --- - - - -
3 potisvalve - -- --- Set the min/max values of local S-valve potentiometer -
Tara I valori min/max del potenziometro S-valve locale
4 --- - -- --- -
5 tempoattesa msec 150 0-10000 Set the value Holding time of endstroke microswiches ON -
Setta il tempo di ritegno del segnale finecorsa ON
6 --- -
7 imin mA 400 200-1000 Set the min current value of RPS valve -
Setta il valore minimo della corrente alla valvola RPS
8 imax mA 1300 1000-2000 Set the max current value of RPS valve -
Setta il valore massimo della corrente alla valvola RPS

Cifa_rps2.0
CIFA SpA 29/10/2012
Via Stati Uniti d'America, 26
20030 - Senago (Milano)

3.3. Diagnostic
Errore Error Description
number
and blink
code
RPS VALVE 0 - 00000 Failure on rps magnet or wiring ( Errore sul magnete o cablaggio del magnete valvola RPS )
POTI RPS 1 - 00001 Failure on local RPS Poti or wiring ( errore sul poti RPS o relative cablaggio)
POTI SVALVE 2 - 00010 Failure on local S-VALVE Poti or wiring ( errore sul poti S-Valve o relative cablaggio)
Errore finecorsa 3 - 00011 Error on pumping unit limit switch or wiring ( errore su finecorsa o cablaggio)

GREEN LED blink code Description


ECU ON 5 ECU and program are ok and active

Cifa_rps2.0
CIFA SpA 29/10/2012
Via Stati Uniti d'America, 26
20030 - Senago (Milano)

4. Setup
Necessary setup:

Setting of the stroke limit and curve deceleration in calibration menu


Setting of power parameters in power menu
Setting of maximum and minimum current in currents menu
Setting of S-valve control parameters in S-valve menu

Optinal setup:

Setting of deceleration curve point in Curve 1 menu and Curve 2 menu