The minimum insulation values and minimum clearances have been adhered to
All fastening screws, connection elements and electrical connections have been
firmly tightened to the specified torques
The existing supplementary installations such as temperature monitoring,
downtime heating etc. are connected and operational
Protective measures are in place to prevent contact with the second shaft stub
on the non-drive end
If the second shaft stub on the non-drive end is not used, the fitted key is
secured to prevent its flying free
The installed forced ventilation is ready for operation and connected in
accordance with the specified direction of rotation
Installed brake has been checked for proper function
Corresponding values of the working machine are also recorded where possible
Other notes:
Status at 14.05.2014