You are on page 1of 1

A10

NOTES:
00A UC
1. FOR GENERAL NOTES, SYMBOLS AND DETAILS SEE DRAWING

PB02-HRH-001 Hot reheat steam system


2050 NOTE 1 A10-A-PID-VA-449162-001 THRU A10-A-PID-VA-449165-003.
SEE DETAIL 5 2. TURBINE BYPASS VALVES A10-SP-1102/1202 INCLUDE PCV
A10 FF WITH INTEGRAL DESUPERHEATER.
00A MOV 3. MINIMUM OF 20 PIPE DIAMETERS REQUIRED FROM BYPASS
M VALVE TO TE.
2050
4. LENGTH AS REQUIRED BY BYPASS VALVE VENDOR.
A10-26"-HRH-21001-9CM1P A10-26"-HRH-21001-9CM1P
6720 A10-718600-201 6716 A10-718577-202
HC (583 C) 190 mm RTD FF FREE DRAINING HC (583 C) 190 mm
HRH STEAM FROM HRSG
A10

TE
A10

TT
A10

TI H A10

UC HRH STEAM TO IP STEAM


U-2101 A10
TURBINE A10-P-2001
00A PT 3/4" 2051 2051 2051 2051 NOTE 1
L
2052A 3/4"

FREE DRAINING
00A
n 00A A10-12"-HRH-21003-9CM1P SEE DETAIL 4
A10 A10

UC PT 3/4" HC (583 C) 165 mm A10

AOV
2052 2052B 3/4"
2051
A10-2"-HRH-21004-9CM1P
6714 A10-718586-201
RTD CSO AC/AFO CSO PP (583 C) 90 mm HOLDS: 00A

NNF
A10 A10 A10

TI TT TE 3/4" D 3/4" D HRH HEADER DRAIN TO


00A ATMOSPHERE 151. ALL CONTROL VALVE SIZE HOLD, WAITING VENDOR INFORMATION.
2052 2052 2052
A10 A10
BLOWDOWN TANK
TI TC 1" D A10-D-2104
2053 2054
A10 A10
HC (583 C) 125 mm PP (583 C) 90 mm
FI A10 PC I
UC 00A
2053 A10
2052
TT 2053
NOTE 1 n
2053 A10
HH
A10 SEE DETAIL 40 UC H
SEE DETAIL 4 PV 00A
2054
PDI
A10

FT
A10
RTD A10-24"-HRH-21002-9CM1P 2052 L
A10

TE AOV
A10 A10

TV HC (583 C) 175 mm PI
A10
H
2053 2053 NOTE 2
2053 2053 2054 AFC 2054 A10 A10

3/4" 3/4" 1/2" SP TT TT LEGEND


A10-8"-MPC-21017-3CC1P1 NNF
6717 A10-718584-205 2102 2054A 2054B PIPING MATERIAL INSTRUMENT DEFINITION & SYMBOLS SAES-J-004
HC (45 C) 40 mm AO/AFC AO/AFC A10
SPECIFICATION SAES-L-105
AC/AFO -AIR TO CLOSE/ VE -VIBRATION ELEMENT
SPRAY WATER FROM A10 1" D 1" D 1" D PT AIR FAILURE OPEN VS
SP 3CC1P1 9CM1P -VIBRATION SWITCH
CONDENSATE PUMP FE RTD RTD AC/AFS -AIR TO CLOSE/AIR VT
00A 2054 PROCESS LINE -VIBRATION TRANSMITTER
DISCHARGE 2053
A10 A10
FAILURE STEADY XL -PILOT LIGHT
2190 TE TE
A10-G-2001A/B INSTRUMENT AO/AFC -AIR TO OPEN/ (NOT FOR MOTOR)
2054A 2054B AIR LINE AIR FAILURE CLOSE XS -LIMIT SWITCH

3/4"
00A INSTRUMENT
AO/AFS -AIR TO OPEN/AIR ZV -SAFETY SHUTDOWN VALVE
A10-10"-HRH-21010-9CM1P

FAILURE STEADY
ELECTRICAL LINE
A10-42"-HRH-21007-9CM1P NOTE 3 NNF A10-42"-HRH-21005-1CC1P1 AOV -AIR OPERATED VALVE DATA LOGGER POINT
6715 A10-718584-203 F-FLOW P-PRESS.

INPUTS
AT -ANALYZER TRANSMITTER
HC (152 C) 65 mm FREE DRAINING I HC (152 C) 65 mm DT -DENSITY TRANSMITTER
L-LEVEL T-TEMP.
HC (583 C) 150 mm

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL, OR IN PART, SHALL BE OBTAINED FROM THIS DRAWING WITHOUT THE WRITTEN CONSENT OF SAUDI ARAMCO.
HRH HEADER TO X-MISC. A-ALARM
REDUCER ESD -EMER. SHUTDOWN SYSTEM
CONDENSER A10-E-2001 LOCAL PANEL
00A 00A
FC - FLOW CONTROLLER
MOUNTED INSTR.
A10-12"-HRH-21006-1CC1P1 SPECTACLE FV -FLOW CONTROL VALVE
PLATE-OPEN
HC (152 C) 65 mm FCV -FLOW CONTROL VALVE
I (SELF-ACTUATED)
BOARD MOUNTED
INSTRUMENT
SPECTACLE FE -FLOW ELEMENT
NOTE 4 PLATE-CLOSED FG -FLOW SIGHT GLASS
R/G
STATUS LIGHTS
GATE VALVE FHV -FLOW MANUAL CONT. VALVE XL R=RED, G=GREEN
FHTD -FLOW MANUAL TRANSDUCER PILOT LIGHT (DO NOT
GLOBE VALVE FIC -FLOW INDICATOR CONTROLLER USE FOR MOTOR STATUS)
CHECK VALVE FM -FLOW METER
RO -RESTRICTION ORIFICE MOTOR STATUS
PILOT LIGHT
T PLUG VALVE FQI -FLOW TOTALIZER INDICATOR
SP FR -FLOW RECORDER
BALL VALVE ML LOCAL MOUNTED
1" D FT -FLOW TRANSMITTER INSTRUMENT
DOUBLE DISC
RTD 2120 FY -FLOW RELAY
A10 A10 FF A10 A10
GATE VALVE HIC -HAND INDICATOR CONTROLLER
MOUNTED BEHIND
TE TT TI UC ANGLE VALVE HS -HAND SWITCH LOCAL PANEL
LA -LEVEL ALARM
2055 2055 2055 2055 -LEVEL CONTROL VALVE
L PRESS.RELIEF VALVE LV RACK MOUNTED
NOTE 1 LCV -LEVEL CONTROL VALVE (OR BACK OF PANEL)
(SELF-ACTUATED)
SEE DETAIL 4 LG -LEVEL GAUGE GLASS ELECTRICAL
LIC -LEVEL INDICATOR CONTROLLER SUPPLY REQUIRED
VACUUMRELIEF VALVE -LEVEL INDICATOR
A10 LI
AOV LR -LEVEL RECORDER INSTRUMENT
LS -LEVEL SWITCH AIR SUPPLY REQUIRED
M MOTOR OPERATED
2055 LT -LEVEL TRANSMITTER
VALVE H
LTD -LEVEL TRANSDUCER HIGH LOW
A10-2"-HRH-21011-9CM1P ML -MOTOR STATUS LIGHT L
6722 A10-718586-201 -MOTOR OPERATED VALVE
MOV
CSO AC/AFO CSO PP (583 C) 90 mm P
PISTON OPERATED NA -ANNUNCIATOR
3/4" D 3/4" D HRH HEADER DRAIN TO VALVE
TWO PEN RECORDER
PB -PUSHBUTTON
ATMOSPHERIC

A10-2"-LPC-21008-3CC1P1
PC -PRESSURE CONTROLLER FF
BLOWDOWN TANK CONTROL VALVE PV -PRESS. CONTROL VALVE FOUNDATION
1" D A10
A10-D-2104 PCV -PRESS. CONTROL VALVE FIELDBUS INSTRUMENT

UC (SELF ACTUATED)

HC (152 C) 50 mm
BALL TYPE PDC -PRESS. DIFF. CONTROLLER DISTRIBUTED CONTROL/SHARED
HC (583 C) 125 mm PP (583 C) 90 mm NOTE 1 2056M
P

CONTROL VALVE PDI -PRESS. DIFF. INDICATOR DISPLAY SYMBOLS


I SEE DETAIL 5 WITH POSITIONER PDIC -PRESSURE DIFFERENTIAL
(DCS) DISTRIBUTED CONTROL
INDICATOR CONTROLLER
A10 FF S
SOLENOID VALVE PDIS -PRESSURE DIFFERENTIAL
SYSTEM, OPERATOR ACCESSIBLE
IN CONTROL ROOM
00A MOV
M INDICATOR SWITCH (DCS) DISTRIBUTED CONTROL
2056 VALVE NORMALLY
PDT -PRESS. DIFF. TRANSMITTER
SYSTEM, OPERATOR INACCESSIBLE
PDTD -PRESS. DIFF. TRANSDUCER IN CONTROL ROOM
CLOSED
A10-26"-HRH-22001-9CM1P A10-26"-HRH-22001-9CM1P PG -PRESSURE GAGE
6721 A10-718600-202 6711 A10-718577-202 PI -PRESSURE INDICATOR (DCS) DISTRIBUTED CONTROL
HC (583 C) 190 mm FREE DRAINING HC (583 C) 190 mm SYSTEM, OPERATOR INACCESSIBLE
PIC -PRESS. INDICATOR CONTROLLER
HRH STEAM FROM HRSG RTD FF HRH STEAM TO IP STEAM IN FIELD
A10 A10 A10 A10
PR -PRESSURE RECORDER
U-2201 A10 TE TT TI UC TURBINE A10-P-2001 PS -PRESSURE SWITCH
00A PT 3/4" 00A PT -PRESSURE TRANSMITTER DISTRIBUTED CONTROL
2058 2058 2058 2058
2057A 3/4" L 00A PX -PRESSURE POINT INTERCONNECTING LOGIC

FREE DRAINING
NOTE 1 PY -PRESS. COMPUTATION MOD. CONTROLLER WITH BINARY
n 00A PZV -PRESSURE RELIEF VALVE OR SEQUENTIAL FUNCTIONS
A10 A10
SEE DETAIL 4
UC PT 3/4" RTD -RESIST. TEMP. DETECTOR
A10-12"-HRH-22003-9CM1P A10 SI -SPEED INDICATOR
(PLC) PROGRAMMABLE LOGIC
CONTROLLER, NORMALLY
2057 2057B 3/4" HC (583 C) 165 mm AOV SS -SPEED SWITCH INACCESSIBLE OR BEHIND THE
TC -TEMP. CONTROLLER PANEL DEVICE OR FUNCTIONS
2058 TV -TEMP. CONTROL VALVE
A10 A10 A10
RTD (PLC) PROGRAMMABLE LOGIC
TCV -TEMP. CONTROL VALVE CONTROLLER FUNCTION,
TI TT TE A10-2"-HRH-22004-9CM1P (SELF-ACTUATED) CAN BE NORMALLY
6712 A10-718586-203 DISPLAYED ON CRT
2057 2057 2057 CSO CSO PP (583 C) 90 mm TE -TEMP. ELEMENT
TSO -TIGHT SHUT OFF
3/4" DAC/AFO 3/4" D HRH HEADER DRAIN TO TG -THERMOMETER LOCAL DCS OR AUXILIARY
NNF

S.C. - SAMPLE CONN. THS -TEMP. HAND SWITCH DCS LOCATION NORMALLY
00A ATMOSPHERE ACCESSIBLE TO OPERATOR
TI -TEMP. INDICATOR
A10 A10
BLOWDOWN TANK S -DRAIN TO
TI TC PRESSURE SEWER TR -TEMP. RECORDER
A10 1" D A10-D-2204 TS -TEMP. SWITCH
(PLC) PROGRAMMABLE LOGIC
2059 2060 PC HC (583 C) 125 mm PP (583 C) 90 mm OWS -OILY WATER SEWER TT -TEMP. TRANSMITTER
CONTROLLER I/O POINT
NORMALLY INACCESSIBLE
A10
D -DRAIN TTD -TEMP. TRANSDUCER BY OPERATOR
FI A10
2057 I TW
V -VENT -THERMOWELL
UC
2059 A10

TT 2059 00A n
NOTE 1 REFERENCE DRAWINGS
2059 SEE DETAIL 40
A10

UC HH
H LETTER IDENTIFICATION OF LINES AE-036204
A10

SEE DETAIL 4 PV 2060 PIPING SYMBOLS AB-036227


L
A10 A10
RTD A10-24"-HRH-22002-9CM1P 00A EQUIPMENT SYMBOLS AB-036305
PDI FT A10 A10 A10 2057
TE AOV TV HC (583 C) 175 mm A10 INSTRUMENT SYMBOLS AC-036950
H
A10

2059 2059 NOTE 2 PI TT A10

2059 2059 2060 AFC PIPING LAYOUT INDEX


TT
3/4" 3/4" 1/2" SP 2060 2060A PLOT PLAN
A10-8"-MPC-22017-3CC1P1 NNF 2060B
6718 A10-718584-205 PROCESS FLOW DIAGRAM
2202
HC (45 C) 40 mm AO/AFC 1" D AFC HYDROSTATIC TEST DIAGRAM
SPRAY WATER FROM 1" D 1" D 3CC1P1 9CM1P
A10-10"-HRH-22010-9CM1P

A10

SP FE
A10

PT RTD RTD DRAWING CONTROL FOR J.O.


CONDENSATE PUMP A10 A10

DISCHARGE 00A TE TE INSTRUMENT INSTALLATION SCHEDULES


2290 2059 2060
A10-G-2001A/B 2060A 2060B
HC (583 C) 150 mm

00A
Jazan - \A10\A10\VA-718577-201.pid - 9/28/2015 9:33:28 AM - [JE07]

3/4"

A10-42"-HRH-22007-9CM1P NOTE 3 NNF A10-42"-HRH-22005-1CC1P1


6713 A10-718584-203
HC (152 C) 65 mm FREE DRAINING HC (152 C) 65 mm
00A HRH HEADER TO
A10-12"-HRH-22006-1CC1P1 00A CONDENSERA10-E-2001
HC (152 C) 65 mm

A10
RTD A10 FF A10 A10 NOTE 4 REVISION VALIDATION
TE TT TI UC
THIS REVISION NO. 00A IS COVERED, FOR ALL APPROVAL AND CERTIFICATION
2056 2056 2056 2056
L REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATE NO:
NOTE 1 1" D T
10-01525-0004-XXX
SEE DETAIL 4 SP
DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS OTHER
(DESIGN AGENCY) REQUIRED (SAUDI ARAMCO)
A10
2220
AOV ENGG./DATE CERTIFIED BY/DATE CONST. AGENCY/DATE OPERATIONS/DATE BY/DATE
L.GAO B.ANDERS
2056 09/25/15 09/25/15

A10-2"-HRH-22011-9CM1P REV.NO. DATE REVISION DESCRIPTION

A10-2"-LPC-22008-3CC1P1
6723 A10-718586-203 00A 09/25/15 ISSUED FOR CONSTRUCTION
CSO AC/AFO CSO PP (583 C) 90 mm
3/4" D 3/4" D HRH HEADER DRAIN TO
JOB ORDER/EWO NO.
ATMOSPHERIC THIS REVISION IS NOT TO BE USED FOR
10-01525-0004

HC (152 C) 50 mm
BLOWDOWN TANK CONSTRUCTION UNTIL CERTIFIED AND DATED
1" D A10-D-2204
HC (583 C) 125 mm PP (583 C) 90 mm
SAUDI ARABIAN OIL COMPANY
I DRAWING TYPE
PIPING & INSTRUMENTATION DIAGRAM PID

A10-12"-LPC-20016-3CC1P1 I I A10-12"-LPC-20016-3CC1P1 BLOCK #2 HOT REHEAT STEAM SYSTEM


6699 A10-718576-201 6719 A10-718577-202
HC (587 C) 165 mm HC (587 C) 165 mm POWER GENERATION UNIT
DRAIN FROM A10-P-2001 DRAIN TO STAND PIPE
(D21) JAZAN SAUDI ARABIA
PLANT NO. INDEX DRAWING NUMBER SHT. NO. REV. NO.

A10 A VA-718577 201 00A


Saudi Aramco 5994 ENG. (09/03)

RESTRICTED SMART CADD-05