You are on page 1of 1

1 Tag Number 424 FI -1004 -E

GENERAL 2 Service E-2460 RETURN LINE


3 PEFS No(Owner Ref) PEFS No.(Consult. Ref) BTU.2.90.1051 2401-8110-25-8002
4 Line Number 4"-P24667-NGDE9-C
PIPING DATA 5 Line Size Line Sched. 4 in 40S
6 Line I.D. Line Material 4.026 in 304 S.S.
7 Fluid Phase LNG Liquid
8 Flow Max. Flow Min. 15600 kg/h 5994 kg/h
9 Flow Operating Full Scale 11988 15600 kg/h
10 Design Pressure Oper. 87.7 bar-g 68.32 bar-g
11 Design Temperature Oper. -180 C -144.4 C
12 Liq. Density @ Base Oper. kg/m 431.3 kg/m
PROCESS 13 Viscosity at Operating Conditions 0.085 cP
CONDITIONS 14 Base Press. Base Temp 14.696 psi 60 F
15 Compressibility @ Oper. Cond.
16 Specific Heat Ratio Cp/Cv
17 Liquid Vapor Pressure 7.384 bar-a
18 Liquid Critical Pressure 48.54 bar-a
19 Vapour Density kg/m
20
21
22 Orifice Plate Type Square Edge Orifice Flange Tappings [ ISO 5167 (1998)/
23 Material 316 S.S.
24 Plate thickness 1/8 in
ORIFICE 25 Bore Diameter Beta Ratio 1.739 in 0.432
PLATE AND 26 Pipe Reynolds No @ Normal Flow
FLANGE 27 Drain or Vent Hole Drain/Vent Hole Pos. in
28 Ring Material Ring Type * *
29 Single or Dual Tapping Single Tapping
30 Taps Type Taps Size Taps Orient. Welded NIpple 1/2 in 4 or 8
31 Flange Size 4 in
32 Flange Rating Gasket Material ANSI 900 # RF *
33 Flange Material 304 SS
34 Bore Accuracy (Max/Nearest 1/8") *
35 Pressure Loss @ Meter Max Flow 198.7 mbar
36 Seal Spec. Gravity at 60 deg F
METER 37 Type of Meter Static Press. Range Differential Pressure
38 Meter Max Flow 15600 kg/h
39 Differential Pressure @ Full scale 250 mbar
40 Chart of Scale Range Chart Multiplier
41 Manufacturer TERCOM
PURCHASE Model
42
43 Requisition Number
44 Serial Number Item Number
45 Owner Ref. No. BTU.2.20.6706
DATA SHT. NO
46 Consultant Ref. No. 2400-8550-DS-8011
Notes: See notes

F1 TZY NAMN NAMN 7/4/2007 FINAL ISSUE


A3 CJF FT FT 3/2/2007 Re-issued for use INSTRUMENT SPECIFICATION
A2 CFJ FT FT 12/11/2006 Re-issued for use
Orifice Plate - MDD
A1 CJF FT FT 11/30/2006 Issued for use
O1 CJF FT FT 11/15/2006 Issued for comments Sheet 1 of 2
No. By Chk. Auth. Date Description Code: 9005 BTU.2.20.6706 Rev.: F1

You might also like