ZOLL

Defibrillator Monitor Pacemaker

The Smallest, Lightest, Most Advanced


Defibrillator Monitor Ever Made
ZOLL M Series All the Capabilities Youll Ever Need
Straightforward controls, Only 11 lb (5 kg). Half the weight
intuitive menus, and ZOLLs and a third of the size of any unit
Uniform Operating System in its class. The M Series has
make operation simple everything you need for cardiac
and reduce staff training resuscitation: fast, easy-to-use
requirements.
defibrillation, external pacing, ECG
High Contrast screen, with with advanced monitoring, built-in
improved readability, and wide AC or DC power, and an integrated
angle of view (60), is superior Code Marker System for all drugs and A universal connector for paddles and
to any LCD display. information management system. interventions makes charting easy. pads eliminates confusing adaptors
Information can be printed either on a and misconnections that can delay
Error Correction minimizes Summary Report or easily downloaded to life-saving efforts.
problems during use by a PC using the removable PCMCIA card.
providing helpful prompts
for corrective action.
M Series Specifications Synchronized Mode: Synchronizes defibrillator pulse Print-out Modes: Manual or automatic - user-
Durable Xtreme Pack jacket to patients R-wave. SYNC message displayed on configurable.
provides convenient storage ECG Monitoring monitor. Marker on display and recorder paper On/Off Control: Front panel and paddle.
identifies R-wave discharge point.
for all cables, electrodes, and Patient Connection: 3-lead ECG cable, 5-lead ECG Advisory Function: Single analysis or programmable
Automatic Function: 15-second recording initiated
by alarm activation or defibrillator discharge.
batteries. cable, 12-Lead ECG cable, paddles or MFE Pads.
Selectable by front panel switch.
auto re-analyze x3 with programmable auto energy
level selection, screen prompts, and voice prompts.
Full range of models are available Input Protection: Fully defibrillator protected. AED Function: Auto analyze and charge x3 with
PCMCIA Card Slots
from Manual to Advisory and Special circuit prevents distortion of ECG by programmable auto energy level selection, screen Accepts two standard series Type II Flash Cards, 1-16
pacer pulse. (Pacer version only.) prompts, and voice prompts. MB: Fax modem card capability in slot 2.
AED to meet all needs and are Implanted Pacemaker Spike Display: Dedicated Charge Controls: Control on apex paddle and on
fully upgradeable to keep pace circuitry detects most implanted pacemaker spikes device front panel. PCMCIA Card
and provides standard display marker of spike
with changing demands. on ECG trace. Paddles: External anterior/anterior adult and pediatric. Records continuous ECG and device data; optionally
records digitally compressed audio data; play on PC
Adult paddles slide off to expose pediatric paddles.
Bandwidth: 0.5-40 Hz (-3 dB) or 0.5-30Hz; with Specified Card Reader and ZOLL Data Control.
0.05-150 Hz diagnostic. Multi-Function Electrode (MFE) Pads: Specifically
designed adult anterior/posterior pre-gelled ZOLL
Lead Selection: Displayed on monitor. MFE Pads, and Multi-Function statpadz packaged Battery Packs
ZOLL Medical Corporation ECG Size: 0.5, 1, 1.5, 2, 3 cm/mV - display in pairs. Type: Rechargeable, sealed lead acid.
32 Second Avenue on monitor.
Burlington, Massachusetts 01803-4420 U.S.A. Built-In Defibrillator Tester: Tests defibrillator energy Recharge Time: 4 hours or less with integral charger.
800-348-9011 Heart Rate: Digital display 0-300 bpm 5%. output and continuity of universal cable and paddles; Operating Time: For a new, fully charged battery pack
781-229-0020 Heart Rate Alarm: On/Off displayed on monitor. documented on PCMCIA card and strip chart. at 20C: 35 defibrillator discharges at maximum
781-272-5578 Telefax User-selectable, tachycardia 60-280 bpm, Defibrillation Advisory: Evaluates electrode connection
www.zoll.com energy , or 3 hours of continuous ECG monitoring,
bradycardia 20-100 bpm. and patient ECG to determine if defibrillation or 2.5 hours of continuous ECG monitoring/pacing at
ZOLL Medical European Operations 1 Volt ECG Out: 1.0 volt/cm of deflection on is required. 60 mA, 80 beats/min.Additional parameters will effect
Dodewaard, the Netherlands strip chart recorder. < 25 ms delay from operating time. Consult your operators guide.
+31 488 4111 83 Shockable Rhythms: Ventricular fibrillation with
+31 488 4111 87 Telefax patient ECG input. amplitude > 100 V and wide complex ventricular
zolleur@worldonline.nl Display Format: Non-fade moving bar display. tachycardia with rates greater than 150 bpm. General
ZOLL Medical U.K. Ltd. SmartAlarms: Beeper/voice prompts indicate Multi-Function Electrode Impedance Measurement Size: 6.8 in (17.3 cm) high x 10.3 in (26.2 cm)
Cheshire, England shockable rhythm. Range: 0-250 ohms. wide x 8.2 in (20.8 cm) deep.
+44 1925 846 400 Weight: 11.5 lb. (5.23 kg) with Multi-Function
+44 1925 846 401 Telefax Display Pacemaker (Pacer Version Only) Cable and battery; 13.5 lb. (6.14 kg) with paddles.
ZOLL Medical Deutschland GmbH Screen Type: High-resolution display. Type: VVI demand; asynchronous (fixed rate) when Design Standards: Meets or exceeds UL 2601,
Kln, Germany used without ECG leads or in ASYNC pacing mode. AAMI DF-39, AAMI DF-2, and IEC 601-2-4.
+49 221 398 9340 Screen Size: 5.6 inches (14.2 cm) diagonally.
+49 221 398 9336 Telefax Sweep Speed: 25 mm/sec. Pulse: Rectilinear, constant current; 402 milli- Patient Safety: All patient connections are
seconds; amplitude variable 0 to 140 mA 5% or electrically isolated.
ZOLL Medical the Netherlands Viewing Time: 4 seconds. 5 mA, whichever is greater; digitally displayed on the
Dodewaard, the Netherlands Environmental: Operating Temperature:
Channels: 2. monitor (increments or decrements by a value of 0 to 55C; Storage and Shipping Temperature:
+31 488 4111 83 2 mA); rate variable from 30 to 180 ppm 1.5%
+31 488 4111 87 Telefax Information: Heart Rate, Lead/Pads, Alarm On/Off, -40 to 65C; Humidity: 5 to 95% relative humidity,
zolleur@worldonline.nl NIBP, 12-Lead ECG, SpO2, EtCO2, AED Functions (increments or decrements by a value of 2 ppm). non-condensing; Vibration: Mil Std 810E, Minimum
and Prompts, Defibrillator Test Function, Self Test Output Protection: Fully defibrillator protected Integrity Test; Shock: IEC 68-2-27, 50g 6mS half sine;
ZOLL Medical Canada
Mississauga, Ontario, Canada Function, Error Corrections and Faults, Pacer and isolated. Operating Pressure: 594 to 1060 mBar;
905-629-5005 Functions (optional), Code Markers, Alarm Selection Multi-Function Electrode (MFE) Pads: Specifically Material Ingress: IEC 529, IP23; Electromagnetic
905-629-0575 Telefax and Limits, Delivered Energy. designed pre-gelled ZOLL statpadzTM, pro-padzTM Compatibility (EMC): CISPR; 11 Class B Radiated
ZOLL Medical France and pedi-padzTM MFE packaged in pairs. and Conducted Emissions; Electromagnetic
Paris, France Defibrillator Immunity: AAMI DF-2: IEC 801-3 to 20 V/m;
+33 1 43 59 2020 Recorder Electrostatic Discharge: AAMI DF-2: IEC 1000-4-2;
+33 1 43 63 5138 Telefax Waveform: Damped sinusoid or Conducted Susceptibility: IEC 1000-4-4, 1000-4-5,
info@zolleur.com ZOLL Rectilinear Biphasic. Paper: 80 mm thermal (grid width). 90 mm 1000-4-6.
Energy Selection: Selectable at 1, 2, 3, 4, 5, 6, 7, 8, (paper width).
ZOLL Medical Australia Pty. Ltd AC Power: Meets all IEC, UL, and AAMI
New South Wales, Australia 9, 10, 15, 20, 30, 50, 75, 100,150, 200, 300, 360 Speed: 25 mm/sec, 6-second delay. safety requirements.
+61 2-94208733 joules. (Delivered into 50 load.) Selected using Annotations: Time, date, defib energy, heart rate,
controls on sternum paddle or device front panel. Options: Xtreme Pack I Carry Case
+61 2-94209834 Telefax pacer output (pacer version only), QRS sync marker, Xtreme Pack II Durable Rubber Case for
Rectilinear Biphasic energy selection up to ECG size, lead, alarm, defib test OK/Fail, analyze
ZOLL Medical Far East Regional Office 200 joules maximum. added protection.
New South Wales, Australia ECG, analysis halted, noisy ECG, shock advised,
+612 43 292226 Charge Time: Less than 7 seconds with a new no shock advised, ECG too large, ECG too small,
+612 43 292226 Telefax fully charged battery (first 15 charges to max energy.) and diagnostic bandwidth.
Depleted batteries will result in a longer Printing Method: High-resolution, thermal
ZOLL Medical Middle East and
Africa Region Office defibrillator charge time. array print head.
Dubai, United Arab Emirates Energy Display: Monitor display indicates both
+971 5 065 31504 selected and delivered energy.
+971 4 332 8835 Telefax
ZOLL Medical Japan
Tokyo, Japan
+81 3 5768 0788
+81 3 5768 0788 Telefax
ZOLL Medical Latin America
Parkland, FL 33067 Specifications subject to change without notice.
954-345-4224 ZOLL Data Control, SmartAlarms, Xtreme Pack and statpadz are trademarks of ZOLL Medical Corporation.
954-345-2648 Telefax ZOLL Medical Corporation 2002. All rights reserved. 9656-0143 Printed in USA 20M 4/02