RIG INSPECTION CHECKLIST

Location: DATE:

Compliant
No. ITEM DESCRIPTION COMPLIANCE MEASURE
Yes No
A SUBSTRUCTURE
Housekeeping maintained
A.1

Adequate lighting
A.2

Lights guarded/secured
A.3

Deck openings guarded
A.4

Decking/Grating in good condition
A.5

All elements pinned and secured
A.6

Access adequate and chained when not in use
A.7

Buddy system used
A.8

PPE used
A.9

B. WELDING SHOP
Housekeeping maintained
B.1

Adequate lighting
B.2

1
Lights protected
B.3

PPE used
B.4

PTW policy adhered to
B.5

Fire watch present
B.6

Grinder/brush securely mounted
B.7

Equipped with eye shields
B.8

Welding machines grounded
B.9

Welding leads insulated & in good condition
B.10

Rod holders in good condition
B.11

Hoses in good condition and equipped with
B.12 fittings/gauges, Regulators and flash back arrestors.

Acetylene bottles secured with cups on/arranged wit
B.13 firewall between

Unobstructed access/egress
B.14

C. DRILL FLOOR
Housekeeping maintained
C.1

2
Adequate lighting (properly installed, explosion proof)
C.2
( )
Adequate access
C.3

Adequate emergency lights
C.4

Man riding Winch in good condition marked with SWL
and instructions
C.5


Winches (wires, brakes, drums guard, guide bar) are in
C.6 good condition,
( )
Tools & equipments in good conditions and properly
C.7 stored

Handrails adequate and undamaged
C.8

Openings guarded
C.9

PPE used
C.10

Safety signs posted (general alarm, no smoking, etc)
C.11

Bug blowers guard
C.12

Eyewash available & functional (water change regularly)
C.13
( )
SCBA available, in good condition, tested & certified
C.14

3
Line and rope guides in good conditions
C.15

Mouse hole covered when not in use
C.16

FF extinguishers adequate/functional and unobstructed (2
or More) CO2 15 lb. Or DC 10 lbs.
C.17
)
(
Air hoist mounted/secured in good condition (brakes
C.18 operable, drum with guide, chain/hook installed)

Tong lines in good conditions and properly installed
snubbed when not in use, thimble secured and color-
C.19 coded


Cat line in good condition, color coded and not stored on
Floor
C.20
) (

Tong counterweight buckets adequate, weights inside it,
adequate travel, lines not rub Derrick members)
C.21


Rotary table level in good condition, non-slip surface,
rotary Locks accessible, its hose in good condition.
C.22

4
Kelly spinner hose in good condition, safety chain
attached.
C.23


Kelly cock wrench accessible
C.24

Slip/Handles/dies/pins in good conditions


C.25

V-door chained when not in use
C.26

Drill line anchor secured
C.27

Crown-o-matic checked each tour
C.28

Elmago brake is fully engaged
C.29

Stretcher is available on rig floor for emergency.
C.30

Dropped objects inspection register maintained up-to-date
C.31

Log book for tools carried above the floor.
C.32

All electrical equipments explosion proof
C.33

H2S system (alarm & sensors) operable, checked and
tested
C.34
) H2S&(

5
D. DERRICK
Crown Block
Counterweight climbing assist installed
D.1

Derrick ladder caged
D.2

Escape line properly installed and maintained
D.3

Derrick ladder properly secured, min 4 clearance, free of
Damage, 12 between rungs, access clear.
D.4
)
(
Crown sheaves in good condition
D.5

Crown free of loose objects
D.6

Crown block in good condition
D.7

Aircraft warning lights installed and operable
D.8

Lights operable and attached with safety chains
D.9

Electrical wiring secured
D.10

Stand pipe secured and braced, equipped with safety
cables/chain, hoses not rubbing derrick members
D.11
/

6
Drill line roller guide properly installed, rollers free and
D.12 operative, sheaves free & in good condition

Monkeyboard
Monkeyboard undamaged
D.13

Escape BA units available and in good conditions
D.14

Unobstructed access/egress
D.15

Level/free of slip/trip hazards,
D.16

Handrails, toe plates in good condition
D.17

Free of loose objects
D.18

Safety belts in good condition w/belly & tail lines and fall
Arrestors
D.19


Fingerboard/fingers in good conditions w/safety chain
D.20

Stabbing board
Stabbing board undamaged,
D.21

Unobstructed access/egress
D.22

Handrails, toe plates in good condition
D.23

7
Belly buster/lanyard and fall arrestors provided/used
D.24

Lights operable & attached w/safety chain
D.25

Hoist and controls operable
D.26

Equipped with stops
D.27

Board guides properly secured
D.28

Safetyline attached
D.29

Top Drive
Emergency stop is functional and tested
D.30

Safety alarms operable, tested (pressuring, cooling flow
)system and overheating indicators/shutdown
D.31
)
(
Check noise, vibration and oil leaks
D.32

Drip pan installed below rotary
D.33

E. BOP
Housekeeping around BOP
E.1
)(BOP
?Are all pressure lines snubbed
E.2

8
Are all fittings in BOP high pressure and H2S trim?
E.3 ( BOP)

When remote control was tested last time?
E.4

When was last accumulator test?
E.5
(KOMMY UNIT)
BOP drills conducted, findings recorded and followed up?
E.6 ( BOP)

F. SHALE SHAKER
Housekeeping maintained
F.1

Adequate lighting (properly installed, explosion proof)
F.2

SS motors properly guarded
F.3

Eyewash facilities installed and operative
F.4

PPE used
F.5

Handrails in good condition
F.6

Deck grating in good condition
F.7

Deck openings guarded
F.8

Unobstructed access/egress
F.9

9
FF equipment adequate, functional & unobstructed (2 or
more) CO2 15 lb. Or DC 10 lbs.
F.10

) ( CO2
G. MUD PUMP
Housekeeping maintained
G.1

)Adequate lighting (properly installed, explosion proof
G.2

Motors properly guarded
G.3

)Relief valve tested weekly (not painted over
G.4

Rotating parts guarded
G.5

Safety valves on each pump not painted over
G.6

Have lockout plate/pin attached
G.7

Drain holes covers adequate and used
G.8

FF extinguishers adequate, functional and unobstructed (2
or more) CO2 15 lb. Or DC 10 lbs.
G.9

) ( CO2
Unobstructed access/egress
G.10

H. MUD TANK
Housekeeping maintained
H.1

10
)Adequate lighting (properly installed, explosion proof
H.2

Walkways, steps, handrails & grating in good condition
H.3

Equip./Machinery guarded
H.4

Adequate ventilation
H.5

Caustic Soda mixing barrel (safe design, warning posted
and PPE available
H.6


FF equipment adequate & functional and unobstructed (2
)CO2 15 lb. Or DC 10 lbs. Or more
H.7

) ( CO2
I. FORKLIFT
Warning devices operable, horn & back-up alarm or
flashing Light
I.1


Rated lifting capacity stenciled on unit
I.2

Drivers overhead guard
I.3

Wheel guards
I.4

Portable 4 lb. DC FF in area during refueling operation
I.5

11
Correct battery charging
I.6

Correct diesel refueling procedure
I.7

Brake operable
I.8

Free of oil leaks
I.9

J. PAINT LOCKER
Properly constructed as per regulation
J.1

Covered rags container
J.2

Adequate ventilation
J.3

Instructions posted
J.4

Inspected/serviced annually
J.5

Pressure release mechanism
J.6

FF CO2 fixed (auto) system installed and certified
J.7
CO2
Warning signs posted (Flammable, Non-smoking, Keep
door closed)
J.8
)
(
FF at exit foam gal. Or 2-15 lb or DC 10 lb
J.9
( )
12
K. MOTOR ROOM/MOTORS
Housekeeping maintained
K.1

Adequate lighting
K.2

) Adequate emergency lighting (tested weekly/marked
K.3 )
(
All motors/equips. Guarded
K.4

Engines free of oil leaks
K.5

FF extinguishers adequate and unobstructed
K.6

Unobstructed access/egress
K.7

SCR: High voltage signs available, master shut down
switch identified , lockout procedures used, electrical
switches are of lockable type
K.8 SCR



SCR: Rescue kit available
K.9

A non-conductive floor mat provided in front of each
K.10 switch panel

13
Is the SCR room equipped by emergency lighting for at
K.11 least two of exits?
SCR
Are All switch box, junction box, and connector box
K.12 covers in place and properly labeled.

Is fire detection system working
K.13

Is fire fighting system automatically working
K.14

Are electrical wires and cables properly isolated
K.15

Are safety signs indicating for high voltage visible
K.16

All switches labeled?
K.17

Are all cable trays properly supported?
K.18

Are all cable trays not overloaded
K.19

Lock-out procedure
K.20

Are there spills (oil, lube or fuel) at generator area?
K.21

Hearing protection available& signs visible
K.22

Fire extinguishers avaiable &in good condition
K.23

Generators grounded
K.24

14
All moving machinery properly guarded?
K.25

General housekeeping
K.26

L. CRANES
Unobstructed access/egress
L.1

Adequate lighting
L.2

Cab glass in good condition
L.3

FF ext. portable available
L.4

Hand signals posted
L.5

Load capacity chart posted
L.6

Controls marked/ illuminated
L.7

Only designated staff operate crane
L.8

Equipped with hook load indicator or boom angle
L.9 indicator

SWL tagged on it
L.10

V-belt, shaft, gears guarded
L.11

Fuel tank overflow properly installed
L.12

15
Engine exhaust equipped with spark arrestor
L.13

Free of oil leaks
L.14

Portable foam, CO2, or DC FE in space
L.15
(CO2 )
Boom and members free from damage
L.16

Wire rope in good condition (no kinks, breaks or
L.17 abrasions)
( )
Slings and cables in good condition
L.18

Soft line not used in lifting
L.19

Hooks provided with safety latches when lifting personnel
L.20

No loose bolts or rivets
L.21

Daily checklist followed
L.22

Crane record book maintained (certification, testing and
L.23 maintenance)
( )
Over load warning device and Load rating chart are in
L.24 place

M. FIXED FIRE EXT. SYSTEM
Instructions posted
M.1

16
FOAM: Water/foam supply located outside space
protected, foam tested in last year
M.2
:

CO2 alarm: must sound before gas is released
M.3
: CO2 CO2
Inspected and serviced annually. Inspection checklist to
be documented with the rig mechanic
M.4


ESD? Alarm devices operable
M.5

Switch/connector box cover in place
M.6

Lock out tag used
M.7

Alarm lights installed/operable
M.8

Ear protection available/used
M.9

High Noise signs posted
M.10

Combustible materials isolated
M.11

Unobstructed access/egress
M.12

System covers Engines, SCR, Mud pits & Paint locker
area
M.13
) (SCR

17
N. F F SYSTEM (PORTABLE)
Distributed in line with General arrangement plan
N.1

Properly maintained/clean and inspected/serviced
annually. Inspection checklist to be documented w the rig
N.2 mechanic


Visible and accessible
N.3

CO2: Weighed monthly, tagged & inspected weekly,
Hydrostatic test 5 yearly
N.4
: CO2

DP: Tagged & inspected weekly, Chemical is free
flowing, gauge is functional
N.5
:

Coamings to contain foam in protected space.
N.6

Alarm must be visible in space protected
N.7

Fire fighting gears (fire suits) to be inspected on regular
N.8 basis.

Must have a system for weighing cylinders
N.9

O. CAMP- QUARTERS
Housekeeping maintained
O.1

18
Passageways unobstructed
O.2

Exit marked
O.3

Adequate lighting
O.4

Adequate emergency lighting (tested weekly and marked
O.5 E)

Life jackets adequately distributed each room. Jackets
should have reflecting tape, rig name, whistle and aqua
O.6 light
.

FF adequate and distributed properly
O.7

Fire hose in each level
O.8

Toilets/showers clean
O.9

Catering staff to be health certified and certification
records to be with OH & A at rig site and with Camp boss
O.10 at camp.


Laundry room clean, washers & dryers operable, dryer
vented, filters clean, drive mechanism guarded
O.11
.

19
Video equips. Maintained
O.12

OJT training library complete
O.13

Training records maintained and updated
O.14

P. KITCHEN/GALLEY
Housekeeping maintained
P.1

Range hood filters clean
P.2

Appliances guarded
P.3

Dry goods properly stored and expirt dates checked.
P.4

Chill/freezer boxes clean (door gaskets, internal lights,
alarm functional)
P.5
)
(
Dishwasher water temp. adequate
P.6

Chiller/freezer are operable and in good condition
P.7

FF portable available (CO2 5 lbs. Or DC 10 lbs.)
P.8
( CO2 )
FF fixed one operable (inspected and tested annually),
Instruction posted
P.9
)
(
Q. HOSPITAL
20
Housekeeping maintained
Q.1

Shower/toilets are available and clean
Q.2

Sharp items containers are available and used
Q.3

Medical wastes treated/managed properly as per
Q.4 procedures

Hot/Cold running water available
Q.5

Treatment table is accessible
Q.6

Litter available
Q.7

Adequate lighting
Q.8

Adequate emergency lights\
Q.9

Medical items under lock & key and inventorised
Q.10

Medicines to be stored properly in appropriate
fridge. Expiry dates to be checked regularly.
Q.11


Medical records maintained
Q.12

R. GENERAL
Weekly rig inspection record maintained
R.1

21
Weekly ER drills held
R.2

General alarm bell tested weekly
R.3

Houskeeping maintained in general.
R.4

Wastes generated segregated and properly managed
R.5

Alerts and case studies posted
R.6

Visitor record/sign book
R.7

\Induction (orientation) for visitors
R.8

Station bills posted
R.9

Radio operable
R.10

Frequencies posted
R.11

ER Numbers posted
R.12

Trained personnel available
R.13

PA system operable
R.14

FF equipment adequate & functional and unobstructed (2
)CO2 4 lb. Or DC 2 lbs. Or more
R.15

) ( CO2
22
Watertight doors operable
R.16

Portable H2S monitor available
R.17

Hand tools in safe condition
R.18

HELIDECK
S. LANDING SURFACE
Non-skid
S.1

Adequate drainage
S.2

Recessed tie-down points
S.3

Safety net (5 ) around perimeter
S.4

Wind direction indicator
S.5
( )
Two access routes
S.6

Perimeter lights Yellow & blue alternating not more than
S.7 10

T. PROPER MARKING
Continuous line (16 wide) around perimeter
T.1

Aiming circles
T.2

Rig Identification
T.3

23
Warning signs at each access Beware of Tail Rotor
T.4
( )
U. FIRE PROTECTION
Fire hose station at each access
U.1

Portable fire extinguishers, foam 40 gal. or 002-200 lbs.
U.2 Or DC-100 lbs at each access
( )
Low velocity spray applicator
U.3

Foam Fire system
Operating controls at each hose location
U.4

Hose reel mounted
U.5

Enough hose to cover entire deck
U.6

Nozzle functional in stream spray, & off positions
U.7

V. MAIN DECK/PIPE RACK
Housekeeping maintained
V.1

Adequate lighting
V.2

Lights guarded/shielded
V.3

Deck openings guarded
V.4

Deck/grating in good conditions
V.5

24
Material/Equipment properly secured
V.6

Walkway/work spaces unobstructed
V.7

Tubular material secured
V.8

Wire rope/slings properly maintained and color coded
V.9

Moon Pool
Housekeeping maintained
V.10

Adequate lighting
V.11

Lights guarded/shielded
V.12

Deck/grating in good conditions
V.13

Handrails in good repair
V.14

W. WORK PLATFORM (BOP DECK)
Housekeeping maintained
W.1

Properly installed/good condition
W.2

Deck openings guarded
W.3

Deck/grating in good conditions
W.4

Unobstructed access/egress
W.5

25
Adequate lighting
W.6

Lights guarded/shielded
W.7

Buddy system used
W.8

Winches, wire line & sheaves in good condition
W.9

Work vests available, well stored and in good condition
W.10

BOP STACK
Properly braced
W.11

Free from leaks
W.12

Discharge lines properly anchored
W.13

Adequate lighting
W.14

Lights guarded/shielded
W.15

Inspection carried out by :


Name: Position: