You are on page 1of 27

Ring main Unit Type SF6,Gas-Insulated, 8DJH SIEMENS

11/2013 MV Group Page 1


Ring main Unit Type SF6,Gas-Insulated, 8DJH SIEMENS

Contents
1. What is meant of RMU
2. Where used
3. Types of RMU
4. Advanteges of 8DJH
5. Technical
6. Pricing

11/2013 MV Group Page 2


Ring main Unit Type SF6,Gas-Insulated, 8DJH SIEMENS

1. What is meant of RMU


RMU: Ring main unit (for loops)

11/2013 MV Group Page 3


Ring main Unit Type SF6,Gas-Insulated, 8DJH SIEMENS

11/2013 MV Group Page 4


Ring main Unit Type SF6,Gas-Insulated, 8DJH SIEMENS

2. Where used
Used for power distribution in secondary distribution
systems, such as:
Substations, customer transfer substations, distribution
substations and public utilities.
Industrial plants

3. Types of RMU
Gas\Air
GIS
Insulated Air Insulated
(8DJH)
(Simosec)
SF6 gas
Busbars Air insulated Air insulated
Insulated
Switching
SF6 SF6 Air
devices
Rated
current of 630A Up to 1250A 630A
busbar
Rated
current of Up to 630A Up to 1250A Up to 630A
feeder
Cost High Very high Low

11/2013 MV Group Page 5


Ring main Unit Type SF6,Gas-Insulated, 8DJH SIEMENS

4. Advantages of 8DJH
1.Service life: Under normal operating conditions,
the expected service life is at least 35 years,
probably 40 to 50 years
2.Personal safety
Safe-to-touch.
HV HRC fuses and cable sealing ends are only
accessible when outgoing feeders are earthed
Operation only possible when enclosure is closed
Logical mechanical interlocking
Capacitive voltage detecting system
Feeder earthing via make-proof earthing switches.
3.Maintenance-free design
4.Maximum supply reliability
5.Installation, operation, extension and replacement
without SF6 gas work
6.Reduced operating costs
7.Cost-efficient investment.
8.Type and routine-tested
9.Small dimensions
10. Standardized

11/2013 MV Group Page 6


Ring main Unit Type SF6,Gas-Insulated, 8DJH SIEMENS

5. Technical

5.1. Technical Features


Up to 17.5 kV, 25 kA or 24 kV, 20 kA
Busbar 630 A, feeders up to 630 A
Factory assembled, type tested switchgear
acc. to IEC 62271-200
Metal-enclosed
Single busbar
Gas-insulated, sealed for life
Flexible due to extension option and block
formation
Individual panels and block versions

11/2013 MV Group Page 7


Ring main Unit Type SF6,Gas-Insulated, 8DJH SIEMENS

5.2. Technical Data

11/2013 MV Group Page 8


Ring main Unit Type SF6,Gas-Insulated, 8DJH SIEMENS

5.3. Typicals
Typical Description
K Cable feeder
K(E) Cable feeder with make-proof earthing switch
R Ring main feeder
T Transformer feeder
L Circuit breaker feeder
M Metering panel
S Bus sectionalizer panel with switch disconnector
H Bus sectionalizer panel with switch disconnector / fuse
combination
V Bus sectionalizer panel with circuit breaker

11/2013 MV Group Page 9


Ring main Unit Type SF6,Gas-Insulated, 8DJH SIEMENS

5.4. Overview of Typicals for Individual


Panels

11/2013 MV Group Page 10


Ring main Unit Type SF6,Gas-Insulated, 8DJH SIEMENS

11/2013 MV Group Page 11


Ring main Unit Type SF6,Gas-Insulated, 8DJH SIEMENS

11/2013 MV Group Page 12


Ring main Unit Type SF6,Gas-Insulated, 8DJH SIEMENS

11/2013 MV Group Page 13


Ring main Unit Type SF6,Gas-Insulated, 8DJH SIEMENS

5.5.Overview of Panel Blocks


(all optionally extendable on the left and/or on the right)

11/2013 MV Group Page 14


Ring main Unit Type SF6,Gas-Insulated, 8DJH SIEMENS

11/2013 MV Group Page 15


Ring main Unit Type SF6,Gas-Insulated, 8DJH SIEMENS

5.6. Panel design


Ring-Main Feeder (R)

11/2013 MV Group Page 16


Ring main Unit Type SF6,Gas-Insulated, 8DJH SIEMENS

Transformer Feeder (T) (depending on HV HRC fuse)

11/2013 MV Group Page 17


Ring main Unit Type SF6,Gas-Insulated, 8DJH SIEMENS

Circuit-Breaker Feeder (L), with CB type 2

11/2013 MV Group Page 18


Ring main Unit Type SF6,Gas-Insulated, 8DJH SIEMENS

Billing Metering Panel (M)

11/2013 MV Group Page 19


Ring main Unit Type SF6,Gas-Insulated, 8DJH SIEMENS

5.7. Switching devices


A.Three-Position Switch-Disconnector

Application Ring-main feeder Transformer feeder


Voltage Ur kV 12 24 12 24
Current Ir A 630 200
Short-time current
up to Depending on
(1s) Ik 25 20
(3s) kA 20 20 HV HRC fuse
Rated short-circuit Im Up to KA 63 50 63 50
making current (at
50HZ)
Mechanical operating n 1000 / M1 1000 / M1
cycles
Electrical operating n 100 / E3 100 / E3
cycles

11/2013 MV Group Page 20


Ring main Unit Type SF6,Gas-Insulated, 8DJH SIEMENS

B.Vacuum circuit-breaker
Types of Vacuum circuit beaker
I. Type 1.1 with three-position disconnector

11/2013 MV Group Page 21


Ring main Unit Type SF6,Gas-Insulated, 8DJH SIEMENS

II. Type 2 with three-position disconnector

11/2013 MV Group Page 22


Ring main Unit Type SF6,Gas-Insulated, 8DJH SIEMENS

Secondary equipment of the vacuum circuit-breakers


Motor operating mechanism(option)
Secondary components (LV compartment)
Closing solenoid (op on for type 2)
Shunt release
Undervoltage release
Anti-pumping (standard for type 1.1)
Circuit-breaker tripping signal (op on for type 2)
Auxiliary switch (Standard: 6 NO + 6 NC)
Position switch (For signaling closing spring charged)
Mechanical interlock
Operations counter(op on for type 2)

11/2013 MV Group Page 23


Ring main Unit Type SF6,Gas-Insulated, 8DJH SIEMENS

11/2013 MV Group Page 24


Ring main Unit Type SF6,Gas-Insulated, 8DJH SIEMENS

5.8. Operation

A.Front view of ring-main feeder

11/2013 MV Group Page 25


Ring main Unit Type SF6,Gas-Insulated, 8DJH SIEMENS

B.Front view of transformer feeder

11/2013 MV Group Page 26


Ring main Unit Type SF6,Gas-Insulated, 8DJH SIEMENS

C. Front view of circuit breaker feeder

11/2013 MV Group Page 27

You might also like