Jurutera Perunding/Consulting Engineers

Project: Design by: WY Check by:


Job: Rev 0
Date
Data:

Shear load = 20 kN Provided weld length, l = 80 mm


Tension force = 20 kN weld size, s = 6 mm
Moment = 7 kNm Weld strength, pw = 215 N/mm2
Bolt Diameter = 20 mm Plate Thickness, tp = 10 mm
Nos of bolt = 1 End Distance, e = 0 mm
Col. Of bolt = 1 Edge Distance, Lv = 0 mm
Row of bolt = 1

1. Bolt Bearing Capacity Check


Applied shear on each bolt = 20 kN

Pbb = dtppbb
= 200 kN >20kN OK

2. Column Flange Connected Part Bearing Capacity Check


Pbs = kbsdtppbs
= 92 kN >20kN OK

3. Bolt Shear Capacity Check


P s = p sA s
= 50.27 kN >20kN OK

4. Bolt Shear and Tension


Pnom = 0.8ptAt
= 60.32 kN

Applied tension on each bolt = 20 kN

Fs/Ps + Ft/Pnom = 0.73 < 1.4 Shear and tension of bolt is safe.

5. Capacity of Welding
Pweld = pwal where a = 0.7s
= 72.24 kN >20kN OK

6. Bearing Capacity of Plate


Pbs= kbsdtppbs But Pbs 0.5kbsetppbs
= 92 kN = 0 kN OK
Failed
7. Plate Block shear capacity
Pr= 0.6pyt[Lv+Ke(Lt-kDt)]
-21.78 kN <20kN Failed