Professional Documents
Culture Documents
Applications Specifications
Medium to high fiber count requirements Temperature Range (Outdoor Series)
Inter-building duct installations Storage -40 to +75C
Operating -40 to +70C
Lashed aerial
Indoor/outdoor Temperature Range (Riser Series)
Storage -40 to +75C
Industrial outside plant Operating -40 to +70C
Single Jacket, All Dielectric Optical Fiber Cable
Ratings
Riser
UL Type OFNR
cUL Type OFN FT.4
Flame Resistance UL 1666
48 1.800.BELDEN.1 www.belden.com
Single Jacket, All Dielectric Cable
Loose Tube Outdoor, and Indoor/Outdoor Riser Rated (continued)
www.belden.com 1.800.BELDEN.1 49
Single Jacket, All Dielectric Cable
Loose Tube Indoor/Outdoor Plenum Rated
Applications Ratings
Medium to high fiber count requirements Plenum
Inter-building duct installations UL Type OFNP
cUL Type OFN FT.6
Lashed aerial
Flame Resistance NFPA 262
Indoor/outdoor
Campus backbones Specifications
Single Jacket, All Dielectric Optical Fiber Cable
Data Centers
Temperature Range
High Density Cable Trays Storage -40 to +80C
Operating -40 to +70C
Product Description Installation 0 to +60C
Cyclic Flexing (EIA-455-104) 2000 cycles, min.
Dry waterblocking technology used within tubes
and under jacket. Available as Plenum rated cable, Min. Bend Radius
thereby eliminating the need for service entrance Installation 20 x OD
splicing to in-building cable. Small diameter and Long Term 15 x OD
bend radius facilitate installation in tight spaces. Optical Specifications See page 39
Full dielectric construction, no grounding required.
Available with up to 144 fibers. Fibers grouped Fiber Bundle Detail
into sets of 12 for maximum density. Length
Outer Jacket
markings in meters for easy determination of Aramid Strength Overall Tape
Member Barrier
cable length.
Jacket Material
Non-unitized Thermoplastic Color
Unitized Thermoplastic Coded
Jacket
Buffer Tube Thermoplastic Specified Fiber
(Color Coded) Upjacketed
Strength Member E-Glass and Aramid Yarn Central Strength Bundles of up to
Member 12 Fibers Each
Central Strength Member Upjacketed
Color Code (Buffer) Per TIA/EIA 598-B,
See page 39
Jacket Color Black
50 1.800.BELDEN.1 www.belden.com
Double Jacket, Armored Cable
Loose Tube Outdoor, and Indoor/Outdoor Riser Rated
Applications Ratings
Direct burial Riser OFCR
Low to high fiber count requirements
Inter-building duct installations Specifications
Indoor/outdoor Temperature Range (Outdoor)
Industrial outside plant Storage -40 to +75C
Operating -40 to +70C
Product Description Temperature Range (Riser)
Storage -40 to +80C
Gel-filled buffer tube prevents water migration. Operating -40 to +70C
Available as Riser rated cable, thereby
Min. Bend Radius
eliminating the need for service entrance
Installation 20 x OD
splicing to in-building cable. Rodent resistant. Long Term 15 x OD
Available in sizes up to 216 fibers. Length markings
in meters for easy determination of cable length. Optical Specifications See page 39
Jacket Material
Outdoor PE Fiber Bundle Detail
Riser PVC Fiber Outer Jacket
Thermoplastic Bundles
Buffer Tube Thermoplastic Tube
Corrugated
Steel Armor
Strength Member Aramid Yarn Inner
Optical Jacket
Central Strength Member E-Glass Fibers
www.belden.com 1.800.BELDEN.1 51
Double Jacket, Armored Cable
Loose Tube Outdoor, and Indoor/Outdoor Riser Rated (continued)
52 1.800.BELDEN.1 www.belden.com
Double Jacket, Heavy-Duty Cable
Loose Tube Outdoor
Applications Specifications
Direct burial Temperature Range
Harsh environments Storage -40 to +75C
Operating -40 to +70C
Applications requiring good ozone-,
moisture- and weather-resistance Min. Bend Radius
Installation 20 x OD
Long Term 15 x OD
Product Description
Optical Specifications See page 39
Gel-filled buffer tube prevents water migration.
Available with up to 216 fibers.
Fiber Bundle Detail
Jacket Material
Outer Jacket: PE Dry Water-Blocking Polyethylene
System Outer Jacket
Inner Jacket: PE
Aramid
Buffer Tube PBT Optical Strength
Fibers Member
Strength Member Aramid Yarn Polyethylene
Inner Jacket
Central Strength Member E-Glass
Gel-filled Fiber Bundles
Core Wrap Water Swellable Tape Buffer Tube Dielectric Central
Strength Member Binder
Color Code (Buffer) Per TIA/EIA 598-B,
See page 39 Rip Cords
www.belden.com 1.800.BELDEN.1 53
Central Tube Cable
Loose TubeOutdoor, and Outdoor Armored
Applications Specifications
Campus OSP backbones Temperature Range
Drop cable Storage -40 to +75C
Operating -40 to +70C
Telecommunications and data trunk
Direct burial (armored only) Min. Bend Radius
Installation 20 x OD
Lashed aerial Long Term 15 x OD
Optical Specifications See page 39
Product Description
Economical option for low fiber counts. Quick and Fiber Bundle Detail
easy end preparation. Fully waterblocked with
MDPE
gel-filled buffer tube. No rods easy handling. Outer Jacket
Crush, impact and abrasion resistant.
Steel Armor
Jacket Material PE Fiberglass
Strength Member
Buffer Tube PBT
Core Wrap Water Swellable Tape Gel-filled
Buffer Tube
Strength Member Fiberglass
Optical Fibers
Armor Corrugated Steel
Rip Cord
Color Codes Per TIA/EIA 598-B, SINGLE ARMOR ALL DIELECTRIC
(Jacket and Fibers) See page 39
Jacket Color Black
54 1.800.BELDEN.1 www.belden.com