You are on page 1of 50

www.pegkaspanagiotis.

gr

24

2007 , -
,
(American Heart Association)
- ,
.

,

(,
, ),
,
.

,
.

,
,
.


.
O
. , ,
,
,


.
,

, .

;
;


.
115/75 mmHg (/) ,
20 mmHg , 10 mmHg
,
, .
50
.


40%,
25% 50%.

2/3
.


.
(
, - ),

.


1.
2 , 2
.

1
(mmHg)

<120 <80
120129 / 8084
130139 / 8589

1 140159 / 9099
2 160179 / 100109
3 >180 / >110
>140 <90

-
2007

.
, , -
,

. , ,
,

, .

,
, 6.

(
80-100% ). ,
2313 cm ( 23-29 cm)
2815 cm ( 28-35 cm)
. <23 cm
>35 cm
( )
.


2-3 1
. 2 mmHg
.
( I)
( V).
0 mmHg,
( IV,
, ).
(
)
.
,
.

. ,
.
.
, .
(
) ,
.

.


( >20 mmHg / >10 mmHg),
.
, 1-2
.
,

.
(/ >180/110
mmHg),
.
140/90 mmHg ,

.


,
.
, 1,
(, ) ( 2).


1 2
3
140-159 160-179

130- 90-99 100-109 180

139 110
85-89

1-2
*
3

*, #,
,

,
+,

+

,
, -
( 3).



-


( (,
(<55 , ) ,
<65) )

( >55 , >65)
(
,
,

,
)

( ) o





LDL- (>130
mg/dl)

HDL- (A
<40, <45 mg/dl)
(>150 mg/dl)
(>100
mg/dl)


>102,
>88 cm
2007 -

2
,
- ( 2).


(mmHg)


130-139 / ( 4)
2 2-4
85-89

*: -
612

140/90 mmHg
1 *: -
140-159 / 36
90-99
140/90 mmHg
*:
2

2 *: -
36
160-179 /
140/90 mmHg
100-109
*:
2

3 2
180 /
110
,
, 4.

4

3 >160 mmHg
<70 mmHg
3


- (
, , )
X (
Cockroft
Gault)
( ,
, )

2007 -


25%
. ,
( 1)
.

1 , -



25%
40%

25%
10%

, .
,
25% . ,

,
.


(
)

3 , (
24 )
. ,

.

:
1. ,
2. -
3. .


(24 ).

1-2
. ,
( )

.

(masked hypertension),
,
.
-
.
24

.
.






.


,
. , ,
.


,

.
.

(www.dableducational.org www.hypertension.gr).


9.


9 ,
24 (
www.dableducational.org)

Ref
Device Mode AAMI BHS ESH Circumstance Recommendation

A&D UA-631 (UA-779 Life 4


Osc Pass At rest, Recruitment violations Recommended
Source)
8
A&D UA-704 Osc A/A Study details omitted Questionable
18
A&D UA-705 Osc A/A At rest Recommended
3
A&D UA-767 Osc Pass A/A At rest; not high BP Recommended
11
A/A At rest; tables incomplete Recommended
A&D UA-774
Osc
(UA-767 Plus) At rest; Recruitment violations; 2
A/A Questionable
Simultaneous readings

Children Only, Ad hoc protocol adaptation. 53


A&D UA-778 Osc Pass B/A Recommended
(No general validation)
6
A&D UA-787 Osc Pass Recommended
46
A&D UA-853 Osc Pass Minor recruitment modification Recommended
E60
Andon BP3 (KD-931) Osc Pass KD-5915 Equivalence Recommended

Osc
56
Andon KD-391 (Semi- Pass At rest Recommended
Auto)
E42
Andon KD-556 Osc Pass KD-5915 Equivalence Recommended
59
Andon KD-575 Osc Fail At rest Not Recommended
E43
Andon KD-5031 Osc Pass KD-5915 Equivalence Recommended
E45
Andon KD-5913 Osc Pass KD-5915 Equivalence Recommended
57
Andon KD-5915 Osc Pass At rest Recommended
E44
Andon KD-5963 Osc Pass KD-5915 Equivalence Recommended
E46
Andon MD-534 Osc Pass KD-5915 Equivalence Recommended
E35
Braun BP4600 Osc Pass HL-868BA Equivalence Recommended
E40
Braun BP4900 Osc Pass HL-868BA Equivalence Recommended
E41
Braun BP5900 Osc Pass HL-868BA Equivalence Recommended
40
Citizen CH-432B Osc Pass At rest Recommended
16
Colson MAM BP3AA1-2 Osc Pass At rest Recommended
FTS
Foracare Fora D 30 Osc Pass At rest Recommended

Hartmann Tensoval duo 45


Aus & Osc Pass A/A Pass Auscultatory validation only Recommended
control
44
Health & Life HL-868BA Osc Pass At rest Recommended
21
Pass Abstract; Protocol adjustments Questionable
Health & Life HL-888HA Osc
26
A/A At rest Recommended
47
Honsun LD-578 Osc Pass At rest Recommended

IEM 27
Osc A/A Pass At rest Recommended
Stabil-O-Graph
58
Lloyds Pharmacy BP11 Osc Pass At rest Recommended
E64
Medel Check (92187) Osc Pass KD-5915 Equivalence Recommended
E65
Medel Elite (92125) Osc Pass KD-5915 Equivalence Recommended
E33
Medel Idea (91913 IDEA) Osc Pass A/A Pass SAA-102 Equivalence Recommended
15
Pass At rest Recommended

Microlife BP 3AC1-1 Osc 20


Pass A/A Pregnancy; Abstract Questionable
20
Pass B/A Pre-eclampsia; Abstract Questionable
E1
Pass BP 3AC1-1 Equivalence Recommended
Microlife BP 3AC1-1 PC Osc
28
Pass ESRD population Recommended
E2
Microlife BP 3AC1-2 Osc Pass BP 3AC1-1 Equivalence Recommended
E3
Microlife BP 3AG1 Osc A/A BP 3BT0-A Equivalence Recommended

BP 3BT0-A Equivalence E4
Microlife BP 3BTO-1 Osc A/A Recommended

7
Microlife BP 3BTO-A Osc A/A Small recruitment violation Recommended
12
Pass A/B Normotensive Pregnancy Recommended

Pass BB Non-proteinuric HBP


Pass A/B Pre-Eclampsia
E5
Microlife BP 3BTO-A(2) Osc A/A BP 3BT0-A Equivalence Recommended
E6
Microlife BP 3BTO-AP Osc A/A BP 3BT0-A Equivalence Recommended
E7
Pass BP A100 Plus Equivalence Recommended
Microlife BP A100 Osc
FTS, 52
Pass With "M-L Size" Cuff Recommended
17
Pass At rest Recommended
Microlife BP A100 Plus Osc
29
Pass At rest Recommended

Microlife Exact BP E21


Osc Pass BP A100 Equivalence Recommended
(BP3MD1-3)
E8
Microlife RM 100 Osc A/A BP 3BT0-A Equivalence Recommended
25
Microlife WatchBP Home Osc Pass At rest Recommended
E27
Microlife WatchBP Home A Osc Pass Watch BP Home Equivalence Recommended
E28
Microlife WatchBP Home S Osc Pass Watch BP Home Equivalence Recommended
FTS
Microlife WatchBP O3 3MZ0 Osc Pass At rest Recommended
48
Nissei DS-400 Osc Pass At rest Recommended
E38
Nissei DS-500 Osc Pass DS-400 Equivalence Recommended

Omron HEM-705CP-II E12


Osc Pass 705IT Equivalence Recommended
(HEM-759-E2)
9
Omron 705IT Osc Pass Recommended
(HEM-759-E) 14
Pass A/A Minor recruitment modification Recommended

Children and adolescents. Reasonable 22


Pass Recommended
adaptation of protocol.

Omron HEM-746C E54


Osc Pass M2 Compact Equivalence Recommended
(HEM-746C-SH)

At rest; "East Wrap" cuff. Poor study and 32


Omron HEM-780REL Osc Pass Questionable
paper

Omron HEM-7051 E48


Osc Pass M3 Intellisense Equivalence Recommended
(HEM-7051-SH)
E20
Omron HEM-7080IC Osc Pass A/A Pass 705IT Equivalences Recommended

Omron HEM-7101 E53


Osc Pass M2 Compact Equivalence Recommended
(HEM-7101-SH)

Omron HEM-Solar E26


Osc Pass M1 Plus Equivalence Recommended
(HEM-4500-SOLE)

Omron IA2 E13


Osc Pass A/A Pass 705IT Equivalence Recommended
(HEM-7011-C1)
E18
Omron i-C10 Pass M6 Comfort Equivalence Recommended
Osc
(HEM-7070-E) E19
Pass A/A M7 Equivalence Recommended

Omron M1 E59
Osc Pass M1 Plus Equivalence Recommended
(HEM-4030-E)

Omron M1 Classic E10


Osc Pass M1 Plus Equivalence Recommended
(HEM-442-E)
E11
Omron M1 Compact Osc Pass M1 Plus Equivalence Recommended
(HEM-4022-E)

Omron M1 Plus 29
Osc Pass At rest Recommended
(HEM-4011C-E)

Omron M2 E49
Osc Pass M3 Intellisense Equivalence Recommended
(HEM-7117-E)

Omron M2 Basic E50


Osc Pass M3 Intellisense Equivalence Recommended
(HEM-7116-E)

Omron M2 Compact 31
Osc Pass At rest Recommended
(HEM-7102-E)

Omron M3 E51
Osc Pass M3 Intellisense Equivalence Recommended
(HEM-7200-E)

Omron M3 Intellisense 31
Osc Pass At rest Recommended
(HEM-7051-E)

Omron M4-I E15


Osc Pass A/A Pass 705IT Equivalence Recommended
(HEM-752-E)
9
Omron M5-I Pass Recommended
Osc
(HEM-757-E) 33
Pass Elderly Population Recommended
19
Pass At rest Recommended
34
Pass General Population Recommended
Omron M6 34
Osc Pass Obese Population Recommended
(HEM-7001-E)
23
Pass Elderly Population Recommended
E23
Pass A/A 705IT Equivalence Recommended
Omron M6 E58
Osc Pass A/A Pass 705IT Equivalences Recommended
(HEM-7211-E)
29
Omron M6 Comfort Pass At rest Recommended
Osc
(HEM-7000-E) E17
Pass A/A M7 Equivalence Recommended

M6 Comfort E56
Omron M6 Comfort Pass Recommended
Osc (HEM-7000-E) Equivalence
(HEM-7221-E)
E57
Pass A/A M7 Equivalence Recommended
38
Pass A/A General population Recommended
35
Omron M7 Pass Population requiring Large Cuff Recommended
Osc
(HEM-780-E) 50
A/A Pregnancy Recommended
50
B/B Pre-Eclampsia (Sample size too small) Questionable
E16
Omron M10-IT Pass M6 Comfort Equivalence Recommended
Osc
(HEM-7080IT-E) E9
Pass A/A M7 Equivalence Recommended

Omron MX2 Basic E55


Osc Pass M2 Compact Equivalence Recommended
(HEM-742-E2)

Omron MX3 Plus 13, FTS


Osc Pass Subject to corrected tables being published Recommended
(HEM-742-E)

Omron SEM-1 E52


Osc Pass M3 Intellisense Equivalence Recommended
(HEM-7051-C12)
49
Oregon Scientific BPU 330 Osc Pass At rest, Plots incorrect Recommended
24
Oregon Scientific BPW810 Pass At rest Questionable
FTS
Panasonic EW3106 Osc Pass At rest Recommended
FTS
Panasonic EW3109 Osc Pass At rest Recommended

Pic Solution (Artsana)


E30
Pic Indolor (Artsana) Osc Pass My Check Equivalence Recommended
Classic Check

Pic Solution (Artsana)


54
Pic Indolor (Artsana) Osc Pass At rest Recommended
Comfort Check

Pic Solution (Artsana)


41
Pic Indolor (Artsana) Osc Pass At rest Recommended
CS 410

Pic Solution (Artsana)


39
Pic Indolor (Artsana) Osc Pass At rest Recommended
CSI 610

Pic Solution (Artsana)


54
Pic Indolor (Artsana) Osc Pass At rest Recommended
My Check

Pic Solution (Artsana)


E31
Pic Indolor (Artsana) Osc Pass My Check Equivalence Recommended
One Check

Pic Solution (Artsana)


54
Pic Indolor (Artsana) Osc Pass At rest Recommended
Personal Check
30
Rossmax ME 701 series Osc A/A Pass At rest Recommended
15
Seinex SE-9400 Osc Pass At rest Recommended

Sensacare SAA-102 36
Osc Pass A/A Pass Three studies. BHS under reported. Recommended
(Standard)
29
Spengler KP7500D Osc Pass At rest Recommended
42
Spengler Pro M Osc Pass At rest Recommended

UEBE Visomat Comfort 43


Osc Pass At Rest Recommended
20/40
51
UEBE Visomat Comfort Eco Osc Pass At rest Recommended

UEBE Visomat Comfort 55


Osc Pass At rest Recommended
Form

Welch-Allyn transtelephonic Parkinson's disease, 30 sub * 2 5


Osc Pass ? Questionable
home monitor measurements

* Note: Grading criteria had not been established though BHS protocol was in operation.5

Device Tables Legend


The following abbreviations are used in the device tables.
Mode Mode of measurement
Hg Standard Mercury

Osc Oscilometric
Aus Ausculatory
AAMI Grading according to the American Association of Medical Instrumentation
Overall pass or fail
BHS Grading according to the British Hypertension Society
Individual A, B, C, D grades for both SBP and DBP
ESH Grading according to the International Protocol of the European Society for Hypertension
Overall pass or fail
Circumstance Circumstance in which they were tested and any other relevant comments.

References for Validation of Upper Arm Devices for Self-measurement of Blood Pressure
Dieterle T, Battegay E, Bucheli B, Martina B. Accuracy and 'range of uncertainty' of oscillometric blood pressure monitors around the
1
upper arm and wrist. Blood Press Moni 1998;3:339-346
Kobalava ZD, Kotovskaia IV, Rusakova OS, Babaeva LA. Validation of UA-767 Plus device for self measurement of blood pressure
2
Clin. Pharmacol. Ther. 2003;12 (2):70-72
Rogoza AN, Pavlova TS, Sergeeva MV. Validation of A & D UA-767 device for the self-measurement of blood pressure. Blood Press
3
Monit 2000;5:227-23d1
Longo D, Bertolo O, Toffanin G, Frezza P, Palatini P. Validation of the A & D UA-631 (UA-779 Life Source) device for self-
4 measurement of blood pressure and relationship between its performance and large artery compliance. Blood Press Monit
2002;7:243-248
5 Herbst T, Anis-Anwar Y, Giacco S, White W. Evaluation of the overall system precision of the Welch-Allyn transtelephonic home blood
pressure monitor in adults with Parkinson's disease Blood Press Monit 2002;7:285-288
Longo D, Toffanin G, Garbelotto R, Zaetta V, Businaro L, Palatini P. Performance of the UA-787 oscillometric blood pressure monitor
6
according to the European Society of Hypertension Protocol. Blood Press Monit 2003;8:91-95
Cuckson AC, Reinders A, Shabeeh H, Shennan AH. Validation of the Microlife BP 3BTO-A oscillometric blood pressure monitoring
7
device according to a modified British Hypertension Society protocol Blood Press Monit 2002;7(6):319-324
Koblava ZD, Kotovskaya YV, Rodionov E Validation of semi-automatic device UA-704 for self-measurement of blood pressure Blood
8
Press Monit 2005;10:223-225
El Assad M, Topouchian J, Asmar R. Evaluation of two devices for self-measurement of blood pressure according to the international
9
protocol: the Omron M5-I and the Omron 705IT Blood Press Monit 2003;8(3):127-133
Verdecchia P, Angeli F, Poeta F, Reboldi GP, Borgioni C, Pittavini L, Porcellati C. Validation of the A&D UA774 (UA-767Plus) device for
11
self measurement of blood pressure. Blood Press Monit 2004;9:225-229
Reinders A, Cuckson AC, Lee JTM, Shennan AH. An accurate automated blood pressure device for use in pregnancy and pre-
12
eclampsia: the Microlife 3BTO-A. BJOG : An International Journal of Obstetrics & Gynaecology 2005;112:915-920
Coleman A, Freeman P, Steel S, Shennan A Validation of the Omron MX3 Plus oscillometric blood pressure monitoring device
13
according to the European Society of Hypertension international protocol Blood Press Monit 2005;10:165-168
Coleman A, Freeman P, Steel S, Shennan A. Validation of the Omron 705IT
14 (HEM-759-E) oscillometric blood pressure monitoring device according to the British Hypertension Society protocol Blood Press Monit
2006;11:27-32
Topouchian JA, El Assad MA, Orobinskaia LV, El Feghali RN, Asmar RG. Validation of two devices for self-measurement of brachial
15 blood pressure according to the International Protocol of the European Society of Hypertension: the Seinex SE-9400 and the Microlife
BP 3AC1-1 Blood Press Monit 2005;10:325-331
Pereira T, Maldonado J. Validao de aparelho de medio automtica da presso arterial Colson MAM BP3AA1-2 segundo o Protocolo
16
da Sociedade Europeia de Hipertenso Rev Port Cardiol 2005;24(11):1341-1351
Stergiou GS, Giovas PP, Neofytou MS, Adamopoulos DN. Validation of the Microlife BP A 100 Plus device for self-home blood pressure
17
measurement according to the International Protocol Blood Press Monit 2006;11:157-160
18 Verdecchia P, Angeli F, Gattobigio R, Angeli E, Pede S, Pittavini L. Validation of the A&D UA-705 device for self-measurement of blood
pressure according to the British Hypertension Society protocol Blood Press Monit 2006;11:223-227
Topouchian JA, El Assaad MA, Orobinskaia LV, El Feghali RN, Asmar RG. Validation of two automatic devices for self-measurement of
blood pressure according to the International Protocol of the European Society of Hypertension: the Omron M6
19
(HEM-7001-E) and the Omron R7
(HEM 637-IT) Blood Press Monit 2006;11:165-171
de Greeff A, Reggiori F, Anthony J, Shennan A. The Microlife 3AC1: An accurate blood pressure measurement device in pregnancy
20
and pre-eclampsia J Hypertens 2006;24 (suppl 4):S279 Abstract P14.475
Tholl U, Assouline E. Validation of the automatic arm type non-invasive blood pressure monitor HL-888HA J Hypertens 2006;24
21
(suppl 4):S285 Abstract P14.496
Stergiou GS, Yiannes NG, Rarra VC. Validation of the Omron 705 IT oscillometric device for home blood pressure measurement in
22
children and adolescents: The Arsakion School Study Blood Press Monit 2006,11:229-234
Altunkan S, Iliman N, Altunkan E. Validation of the Omron M6
23 (HEM-7001-E) upper arm blood pressure measuring device according to the International Protocol in elderly patients Blood Press
Monit 2008;13:117-122
Li L, Wang Hui W, Jin Lan W. Validation of the Oregon Scientific BPW810 blood pressure monitor according to the European Society of
24
Hypertension Protocol. Blood Press Monit 2006;11:343-347
Stergiou GS, Giovas PP, Charilaos P. Gkinos CP, Patouras JD. Validation of the Microlife WatchBP Home device for self home blood
25
pressure measurement according to the International Protocol Blood Press Monit 2007;12:185-188
de Greeff A, Shennan AH. The Health and Life device (HL888HA): accuracy assessment in an adult population according to the British
26
Hypertension Society protocol Blood Press Monit 2007;12:107-111
Westhoff TH, Schmidt S, Zidek W, van der Giet M. Validation of the Stabil-O-Graph blood pressure self-measurement device Journal
27
of Human Hypertension 2007;22,233-235,Research Letter
Thompson AM, Eguchi K, Reznik ME, Shah SS, Pickering TG. Validation of an oscillometric home blood pressure monitor in an end-
28
stage renal disease population and the effect of arterial stiffness on its accuracy Blood Press Monit 2007;12:227-232
Belghazi J, El Feghali RN, Moussalem T, Rejdych M, Asmar RG. Validation of four automatic devices for self-measurement of blood
29
pressure according to the International Protocol of the European Society of Hypertension Vascular Health and Risk Management
2007;3(4):389-400
de Greeff A, Shennan AH. The Rossmax (ME 701 series) upper arm device: accuracy assessment in an adult population according to
30
the International and the British Hypertension Society protocols Blood Press Monit 2008;13:43-48
Asmar R, Khabouth J, Topouchian J, El Feghali R, Mattar J. Validation of three automatic devices for self-measurement of blood
pressure according to the International Protocol: The Omron M3 Intellisense
31 (HEM-7051-E), the Omron M2 Compact
(HEM 7102-E), and the Omron R3-I Plus
(HEM 6022-E). Blood Press Monit 2010;15(1):49-54
Viera AJ, Hinderliter AL. Validation of the HEM-780REL with easy wrap cuff for self-measurement of blood pressure according to the
32
European Society of Hypertension International Protocol Blood Press Monit 2007;12:335-338
Omboni S, Riva I, Giglio I, Caldara G, Groppelli A, Parati G. Validation of the Omron M5-I, R5-I and HEM-907 automated blood
33 pressure monitors in elderly individuals according to the International Protocol of the European Society of Hypertension Blood Press
Monit 2007;12:233-242
Altunkan S, Iliman N, Kayaturk N, Altunkan E. Validation of the Omron M6
34 (HEM-7001-E) upper-arm blood pressure measuring device according to the International Protocol in adults and obese adults Blood
Press Monit 2007;12:219-225
El Feghali RN, Topouchian JA, Pannier BM, El Assaad HA, Asmar RG. Validation of the Omron M7
35 (HEM-780-E) blood pressure measuring device in a population requiring large cuff use according to the International Protocol of the
European Society of Hypertension Blood Press Monit 2007;12:173-178
Zaetta V, Daniele L, Perkovic D, Prattico F, Barisa M, Perfetti P, Gabrieli A, Buonocore F, Winnicki M. Validation of the SAA-102 home
36 blood pressure monitor according to the protocols of the European Society of Hypertension, the Association for the Advancement of
Medical Instrumentation and the British Society of Hypertension Blood Press Monit 2007;12:363-368
Coleman A, Steel S, Freeman P, de Greeff A, Shennan A. Validation of the Omron M7
38 (HEM-780-E) oscillometric blood pressure monitoring device according to the British Hypertension Society protocol. Blood Press Monit
2008;13:49-54
Pini C, Pastori M, Baccheschi J, Omboni S, Parati G. Validation of the Artsana CSI 610 automated blood pressure monitor in adults
39
according to the International Protocol of the European Society of Hypertension Blood Press Monit 2007;12:179184
Cotte UV, Faltenbacher VH, von Willich W, Bogner JR. Trial of validation of two devices for self-measurement of blood pressure
40 according to the European Society of Hypertension International Protocol: the Citizen CH-432B and the Citizen CH-656C Blood Press
Monit 2008;13:55-62
Pini C, Natalizi A, Gerosa PF, Frigerio M, Omboni S, Parati G. Validation of the Artsana CS 410 automated blood pressure monitor in
41
adults according to the International Protocol of the European Society of Hypertension Blood Press Monit 2008;13:177-182
de Greeff A, Ahmed N, Sheppard E, Andrew H. Shennan AH. A self-measurement device suitable for hospital use: validation of the
42
Spengler Pro M according to the International Protocol of the European Society of Hypertension Blood Press Monit 2008;13:183-186
Stergiou GS, Tzamouranis D, Nasothimiou EG, Protogerou AD. Can an electronic device with a single cuff be accurate in a wide range
43 of arm size? Validation of the Visomat Comfort 20/40 device for home blood pressure monitoring Journal of Human Hypertension
2008;23:Advanced Online Publication
Chen HE, Cui Y, Sheng CS, Li LH, Li Y, Wang JG. Validation of the Health & Life HL868BA blood pressure monitor for home blood
44
pressure monitoring according to the European Society of Hypertension International Protocol. Blood Press Monit 2008;13:305-308
de Greeff A, Arora J, Hervey S, Liu B, Shennan AH. Accuracy assessment of the Tensoval duo control according to the British and
45
European Hypertension Societies' standards Blood Press Monit 2008;13:111-116
Bonso E, Ragazzo F, Palatini P. Validation of A&D UA-85X device for blood pressure measurement. Blood Press Monit 2008;13:339-
46
341
Zhang Y, Wang J, Huang QF, Sheng CS, Li Y, Wang JG. Validation of the HONSUN LD-578 blood pressure monitor for home blood
47
pressure monitoring according to the European Society of Hypertension International Protocol. Blood Press Monit 2009;14:128-131
Duhig KE, de Greeff A, van der Westhuizen A, Baker E, Shennan AH. Validation of the Nissei DS-400 in a low-resource setting. Blood
48
Press Monit 2009;14:132-135
Li L, Zhang XY, Yan CH, Liang QX. Validation of the Oregon Scientific BPU 330 for self-monitoring of blood pressure according to the
49
International Protocol. Vascular Health and Risk Management 2008;4(5):1121-1125
de Greeff A, Beg Z, Gangji Z, Dorney E, Shennan AH. Accuracy of inflationary versus deflationary oscillometry in pregnancy and
50
preeclampsia: OMRON-MIT versus OMRON-M7. Blood Press Monit 2009;14:37-40
Perkovic D, Guarnieri C, Palatini P. Validation of the visomat comfort eco blood pressure measuring device according to the
51
International Protocol. Blood Press Monit 2009;14:178-180
Bonso E, Dorigatti F, Palatini P. Accuracy of the BP A100 blood pressure measuring device coupled with a single cuff with standard-
52
size bladder over a wide range of arm circumferences. Blood Press Monit 2009;14:216-219
Narogan MV, Narogan MI, Syutkina EV. Validation of A&D UA-778 blood pressure monitor in children. Blood Press Monit
53
2009;14:228-231
Germano G, Psimenos A, Sarullo F, Venditti A, Pecchioli V, Asmar R. Validation of four automatic devices for self-measurement of
54 blood pressure according to the International Protocol: The Pic Indolor Personal Check, Comfort Check, My Check and Travel Check.
Blood Pressure 2009;18 (Suppl 1):15-23
Bonso E, Dorigatti F, Saladini F, Palatini P. Validation of the Visomat Comfort form device for home blood pressure measurement
55
according to the International Protocol. Blood Press Monit 2010;15(1):63-66
Wan Y, Pan F, Liu Y, Liang Y, Yang Z, Zhao H, Xu Y. Validation of the Andon KD-391 semiautomated blood pressure monitor in adults
56
according to the International Protocol. Blood Press Monit 2009;14:181-184
Huang QF, Wang J, Sheng CS, Zhang NN, Li Y, Wang JG. Validation of the ANDON KD-5915 blood pressure monitor for home blood
57 pressure monitoring according to the European Society of Hypertension International Protocol. Blood Press Monit 2010;15(4):232-
234
Coleman A, Steel S, deGreeff A, Shennan A. Validation of the Lloyds Pharmacy BP11 oscillometric blood pressure monitor according
58
to the International Protocol of the European Society of Hypertension. Blood Press Monit 2010;15(3):163-6.
Pan F, Wan Y, Chen W, Li N, Tong W, Xu Y. Validation of the Andon KD-575 automated blood pressure monitor according to the
59
European Society of Hypertension International protocol in adults. Blood Press Monit 2010;15(3):167-70.

, 1-2
.
7 (
5 ,
)
1-2 .

.
:


:
: 4 :
: __/__/20__ 1: __/__
11 . 2 1. 2:
( 2 ). ..:
: 69 69 . : 1: __/__
5 . 2:
1 . ..:

1 : 5 :
__/__/20__ 1: __/__ __/__/20__ 1: __/__
2: 2:
..: ..:
: 1: __/__ : 1: __/__
2: 2:
..: ..:

2 : 6 :
__/__/20__ 1: __/__ __/__/20__ 1: __/__
2: 2:
..: ..:
: 1: __/__ : 1: __/__
2: 2:
..: ..:

3 : 7 :
__/__/20__ 1: __/__ __/__/20__ 1: __/__
2: 2:
..: ..:
: 1: __/__ : 1: __/__
2: 2:
..: ..:
8 : 10
__/__/20__ 1: __/__ :
2: __/__/20__ 1: __/__
..: 2:
: 1: __/__ ..:
2: : 1: __/__
..: 2:
..:

9 :
__/__/20__ 1: __/__
2:
..:
: 1: __/__
2:
..:
135/85 mmHg
, <130/85 mmHg (
) ( 5)

5
24
(mmHg)

24


# <130/85 <125/80 <130/85 <120/70
* 130-135/85 125-130/80 130-135/85 120/70
# >135/85 >130/80 >135/85 >120/70

#
+ ,
*


24
24
( ).
: ,
, ,

.
24
5.
24.

,
- (
),

( >135/85 mmHg
>120/70 mmHg ),
24
, . :
o <15% ,
o >30% .
24

.

(http://www.dableducational.org www.hypertension.gr).





,
,
- (
, , ,
) .
, ,
,
.

,
.

: , , HDL LDL ,
, , , , ,
, .

Cockroft-Gault*.

Cockroft-Gault

(140 - ) (kg) #

(ml/mi-n)
72 (mg/dl)
# 0,85

-
( ,
) ,
(
).

.



5%.
, ,
(
)
. Cushing,

.
( , ,
, , ,
) ()
.
,
.
,

.

.

. .



. ,

, (
2, 2).
,

3-12 (
) .



( 2).

, -
<140/90 mmHg
( 4),
- <130/80 mmHg
(>65 ), -



3 (
, , , ).


(, , , ).


,
, .


.
,

(, , ). ,
,
.

,
, .
,

, ,
,
.
,
,
.
(5 kg)
.
:
, , ,
,
,
( 2-3 1-2
) .
,
,
,
.


,

, :
o ()

o () 2-
3 .

,
, -
,
(),
.
-
,
( , , ,
).
, -
,
,
, -


, -,
,

.



.

.

:


, -
.
.
.


-,
.

-
.


.




.
( 30%
)
. >2,5-3 mg/dl
<35 ml/min,
().



.
>200/120 mmHg ,
<160/110 mmHg.
, 3-4 ,
<130/80 mmHg .



.
.




.

. , -

.

- -
.

.

()
.


,
,
.

, . ,
(
),
.
>95
, .
,
I V
, .
.

,
. ,

.


( ),
.

-
, ,
2 3 ,
( ).

(, )
2 3 ,
.


(
), ,
, ( ).



.

.

-.
.

.

-
.

,
.
, -

.


.

, .


,
:

-
( 2)

2-3 .
,
.

>160/100 mmHg ( 2
2 ).
, -
<130/80 mmHg,
>150/90 mmHg.

.

.

,
.
:
o

.

( 7-8):
7 per
os

/
(mg/)

Fludex 1,5-2,5 1
Hydrochlorothiazide 12,5-25 1
Hygroton 12,5-25 1
+ Lasix 20-80 2
12,5-
25/1,25-
+ Moduretic 2,5 1
+ 20-
+ 80/2,5-
Frumil 10 2
Aldactone 25-50 1 2
Inspra 25-50 1 2
-A Tenormin 25-100 1
Kerlone 5, 20 1
Pactens 2,5-10 1
Lopresor 50-200 50, 200
Lobivon 2,5-10 1
Inderal 40-180 1-2*
-A Trasicor 80-320 2, 3
Visken 10, 60 2

Selectol 200-400 1
- -A Dilatrend 12,5-50 1, 2
Trandate 100-200 2
Cibacen 10, 40 1, 2
Renitec 5, 40 1, 2
Zofepril, Zopranol 30-60 1, 2
Tanatril 5, 20 1
Capoten 25-100 2
Accupron 10, 40 1
Prinivil, Zestril 10, 40 1
Coversyl 2,5-10 1
Triatec 2,5-20 1
Vascace 2,5-5 1
Afenil/Odrik 1, 4 1
Monopril 10, 40 1
8


(mg/)

/
/ Cibadrex 5/6,25, 10/12,5, 20/25
/
/ Co-Renitec 20/12,5
/
/ Zofepril plus 30/12,5
Zopranol plus
/
/ Superace 50/25
/
/ Accuretic 20/12,5
/ Prinzide,
/ Zestoretic 20/12,5
/
Preterax 2/0,625, 4/1,25
/
/ Triatec Plus 5/25
/
/ Vascace Plus 5/12,5
/
/ Co-Diovan 80/12,5,
160/12,5, 160/25
/
/ Teveten Plus 600/12,5
/
/ Co-Aprovel 150/12,5, 300/12,5,
Karvezide 300/25
/
/ Atacand Plus 16/12,5
/
/ Hyzaar 50/12,5, 100/12,5
/
/ Olartan plus 20/12,5, 20/25
Olmetec plus
/
/ Micardi-s Plus 80/12,5
Pritor Plus
-A /
Tenoretic 50/12,5, 100/25
/
Trasitensin 160/20
/ Viskaldix 5/10


/ / Hygroton-
Reserpine 50/0,25
/
/ Neourizine 0,125/25
/
/ Hydromet 250/15
/
Logi-max 5/47,5
() + -
A
/ Tri-acor, 5/5
+ Uni-tens
/ Eneas, Eni-t 10/20

/ Vi-vace 30/10
()
/ Exforge,
Copali-a 160/5, 160/10
+


()


+

+ /
Tarka 2/180

( )

: , /:




.

.

1. (
).
2. ( ,
, ).
3.
4. (
>3 mg/dl ).
5. (
, , ,
)
6.
.

,
.

-

( 6).


- (
),
. , ,
,


.
,
,
,
.

,




.


3-6
( , -
) 2 4 .
,
.
, .

,
( 10 mmHg -
) 2-3
1 .

.


.

,

.
:
)
,
)
,
)
,
)


) .


.

.
.

.
.



:
o 2 :
2 ,
21, ,
,
.
21
.
o :

.
90

. 24

.

www.hypertension.gr
www.ypertasi.gr
www.escardio.org
http://www.escardio.org/hypheart
www.hcs.gr
www.americanheart.org
www.ash-us.org

You might also like