Linear Polarization Resistance

(LPR) General Information

INTRODUCTION ADVANTAGES
Linear Polarization Resistance monitoring is an The major advantage to LPR monitoring is the
effective electrochemical method of measuring speed in which it can provide a measurement of the
corrosion. Monitoring the relationship between corrosion rate. Changes in the corrosion rate can
electrochemical potential and current generated typically be detected in minutes, providing an almost
between electrically charged electrodes in a process instantaneous measuring system. This fast response
stream allows the calculation of the corrosion rate. allows an operator to evaluate process changes and
LPR is most effective in aqueous solutions, and has is particularly useful in monitoring the effectiveness of
proven to be a rapid response technique. This a prevention program. For example, quick feedback
measurement of the actual corrosion rate allows means that inhibitor selection and quantities can be
almost instant feedback to operators. LPR monitoring evaluated and fine-tuned in minimal time.
has seen wide industry use for nearly 50 years.
Another key advantage of LPR monitoring is that
LINEAR POLARIZATION RESISTANCE THEORY it can provide a qualitative pitting tendency
measurement, such as whether the tendency for
Electrical conductivity (the reciprocal of
pitting will be shallow and infrequent, or deep and
resistance) of a fluid can be related to its
abundant. LPR monitoring can also give an indication
corrosiveness. A two or three electrode probe is
of metal behaviour, for example when an alloy
inserted into the process system, with the electrodes
changes from a passive to an active state, thereby
being electrically isolated from each other and the
resulting in increased susceptibility to corrosion.
process line. A small potential in the range of 20mV
(which does not affect the natural corrosion process), Caproco LPR probes can often have long lives,
is applied between the elements and the resulting depending on the monitoring conditions and
current is measured. The polarization resistance is maintenance care. For projecting probes, the
the ratio of the applied potential and the resulting electrodes are replaceable, which extends probe life
current level. The measured resistance is inversely and offers options in electrode material types for
related to the corrosion rate. different monitoring objectives.
The electrical resistance of any conductor is given by: PROBE TYPES
Caproco produces a variety of LPR probes, each
V
R= of which have different characteristics and
I applications. Consult the selection guide on the
following page for information on different element
types.
Where R = Effective instantaneous resistance
Caproco LPR probes come in three main designs:
V = Applied voltage Retrievable, Retractable and Fixed.
I = Instantaneous current between electrodes
If the electrodes are corroding at a high rate with
the metal ions passing easily into solution, a small
potential applied between the electrodes will produce
a high current, and therefore a low polarization
resistance. This corresponds to a high corrosion rate.
Retrievable Fixed
Retrievable probes can operate in systems Fixed probes are usually mounted on line through
pressurized up to 6,000 psi. The probe is mounted on flanged or NPT threaded bodies. The actual probe
a hollow plug, through a high pressure access fitting. body maintains line pressure, so they cannot be
By using a Caproco retriever and service valve, the removed until the system is shut down, however
probe can be changed / inspected with no interruption readings can be taken at any time without system
to the system. Readings can be taken any time by interruption. Certain models are rated for operating
connecting a portable instrument / data logger or pressures up to 10,000 psi. Fixed probes provide an
probe signal transmitter to the probe's standard 6 pin economical and easy-to-use option for electronic
electrical connector. monitoring.
Retractable Instrument
Retractable probes are intended for lower A critical component to measuring corrosion rates
pressure systems, and are rated up to 1,500 psi. The electronically is the instrument used to interpret the
probe is inserted through a low pressure access data. Caproco has designed a high quality,
fitting, and is secured in place by a safety clamp. It field-proven LPR Analyzer instrument that can take an
can be removed under pressure either manually or by instantaneous corrosion rate measurement, or act as
using a Caproco Sidewinder Retractor, and readings a data logger, storing information for later analysis.
can be taken at any time with no system interruption.

CAPROCO LPR PROBE SELECTION GUIDE

Probe Most Suitable Less Suitable Element


Characteristics Element
Style For Use In For Use In Diameter

Aqueous solutions/systems
2 Element
with water content
-Wide selection of or 0.25"
-Areas that are not pigged or
element materials 3 Element
have hydrates
-Systems with dry gas or
Projecting
-Glass sealed element heavy oil
-Situations where multi-
functional monitoring is
-Replaceable Electrodes 5 Element 0.25"
desired (Electrochemical
Noise, LPR, Galvanic)

-Fluids which attack glass


Flush -Measuring conditions at wall
-Not affected by edge and ceramics (e.g. Fluorides)
Flush (2,3,5 surface 0.25"
corrosion or high velocity -Systems with dry gas or
Element) -Locations that require pigging
heavy oil