Hydro power
Intelligent solutions for
hydroelectric power plant controls
Hydro power
Intelligent solutions for hydroelectric power plant controls
ABB offers advanced control solutions for hydroelectric power Unit Control
plants. With experience on a global level and across a variety Automated start/stop sequences
of plant configurations, you can be assured ABBs solutions Interfaces to:
will provide your plant with a highly integrated control scheme Metering
utilizing reliable, optimized, and proven practices. This brochure Protection
is an overview of many of the advanced applications ABB Mechanical balance of plant
provides for your hydroelectric power plant. Electrical balance of plant
2 Hydro power Intelligent solutions for hydroelectric power plant controls | ABB information brochure
Hydro power
Hydroelectric power plant Automatic Generation Control (AGC)
overview
ABB information brochure | Hydro power Intelligent solutions for hydroelectric power plant controls 3
Hydro power
Joint Control Active Power (JCAP)
Joint Control Active Power (JCAP) provides a plant the ability JCAP functionality
to receive a single MW generation setpoint that may be shared Cost effective active power control features includes:
among a group of several turbine generators. The plant MW Dispatch center communication data-link
setpoint may be either modified at the plant itself, or from any Dispatch center generation MW setpoint
pre-designated remote location. Generating units that desire Plant generation MW setpoint
to operate separately from the JCAP group may be selected to Unit commitment (plant auto start/stop)
individual mode. Unit priority (operator selected, or run time hours)
Plant optimization (economic dispatch)
The Individual Control Active Power (ICAP) provides a setpoint Daily generation schedules
that will be introduced by the operator HMI normally local to Frequency control
the plant. It is possible for the operator to combine any turbine/ Automatic Time Error Correction (ATEC)
generator associated to the joint control operation mode i.e. Communication with governing system
JCAP, or ICAP mode at any time. See Figure 3, Typical Joint Spinning reserve margin control
Control Active Power flowchart. Spinning reserve monitoring
Plant efficiency calculations (optional)
Dispatch (MW) Plant Operator
Plant net head and losses calculations (optional)
MW ramp management
Turbine rough zone management
Or
4 Hydro power Intelligent solutions for hydroelectric power plant controls | ABB information brochure
Hydro power
Joint Control Reactive Power (JCRP)
ABB information brochure | Hydro power Intelligent solutions for hydroelectric power plant controls 5
Hydro power
Joint Control Gate Flow (JCGF)
Joint Control Gate Flow (JCGF) provides a plant the ability JCGF functionality
to receive a single flow setpoint that may be shared among Hydroelectric power plant, regulating dam flow control
a group of sluice gates. The plant flow setpoint may be either features includes:
modified at the plant itself, or from any pre-designated remote Remote center communication data-link
location. Gates that desired to operate separately from the Remote center flow setpoint
JCGF group may be selected to individual mode. Plant flow setpoint
Downstream flow rate-of-change control
The Individual Control Gate Position (ICGP) provides a Reservoir level rate-of-change monitoring
setpoint that will be introduced by the operator HMI normally Volume/flow control (pumped storage applications)
local to the plant. It is possible for the operator to combine Gate flow calculations
any gate associated to the joint control operation mode Gate priority control
i.e. JCGF, or ICGP mode at any time. See Figure 5, Typical Riparian release flow control
Joint Control Gate Flow flowchart.
Or
6 Hydro power Intelligent solutions for hydroelectric power plant controls | ABB information brochure
Hydro power
Application software
&
The ABB Hydroelectric Power Plant applications use the latest OnOff_1
OnOff
microprocessor based technology. These are programmed Out
MMode
using function block type programming, selected from a set
of factory built libraries for functions. In addition to function TestServo_1
EN TestServo Z_Dist_V_Tst
blocks, ABB controllers also supports all IEC-61131-3 GVServo Test
PV
programming languages: structured test, instructions list, TestQuality_1
Scaler_1
sequential function charts, and ladder diagrams, all of which Scaler
TestQuality
Value
Z_Dist_V_Al In Out In
may be used to add additional custom built user functions. In_Val
Good
Unit Err
Out_Val ChannelErr-
ForcedGood
HighLimit
LowLimit
Overflow
Underflow
>=1 Z_Dist_V_Bad
Servo_1
ServoPD
S_Pos S_Ctl Z_Prop_V_AO
S_Ref S_Dev
T_Ref S_YD
T_En S_YP
10.0 S_HL S_HA
-10.0 S_LL S_LA
0.0 S_TR
0 S_TS
ABB information brochure | Hydro power Intelligent solutions for hydroelectric power plant controls 7