You are on page 1of 8

Output

Sl. No. Document Title Document No.


(in KW)

1 600 MW 0%MU 33 Deg C CW Temp PE-DC-324-100-N151 600000

2 480 MW 0%MU 33 Deg C CW Temp PE-DC-324-100-N152 480000

3 360 MW 0%MU 33 Deg C CW Temp PE-DC-324-100-N153 360000

4 600 MW 3%MU 33 Deg C CW Temp PE-DC-324-100-N156 600000

5 480 MW 3%MU 33 Deg C CW Temp PE-DC-324-100-N157 480000

6 360 MW 3%MU 33 Deg C CW Temp PE-DC-324-100-N158 360000

7 600 MW 3%MU 36 Deg C CW Temp PE-DC-324-100-N161 600000

8 VWO 3%MU 33 Deg C CW Temp PE-DC-324-100-N166 629441

9 VWO 0%MU 33 Deg C CW Temp PE-DC-324-100-N167 635917

600 MW 3%MU 76mm HG (A) Back Pr. all


10 PE-DC-324-100-N170 600000
HPHs out

600 MW 0%MU 33 Deg C CW Temp Sliding


11 PE-DC-324-100-N180 600000
Pressure Operation

480 MW 0%MU 33 Deg C CW Temp Sliding


12 PE-DC-324-100-N182 480000
Pressure Operation

360 MW 0%MU 33 Deg C CW Temp Sliding


13 PE-DC-324-100-N186 360000
Pressure Operation

14 BMCR/ VWO 3%MU 3 Deg C CW Temp PE-DC-324-100-N249 624978

600 MW 3%MU 33 Deg C CW Temp one


15 PE-DC-324-100-N177 600150
string of HP Heaters Out

16 House Load Operation PE-DC-324-100-N200 36000

17 600MW 3%MU 28 Deg C CW Temp PE-DC-324-100-N220 600000

60%HP/LPBypass, 3%MU, 33 Deg C CW


18 PE-DC-324-100-N221 -
Temp
NOTE Heat Rate =[Mf x (Es-Ef) + Mc x (Eh- Ec)] x 1000/Output

Where
Mf Mass Flow Rate of Feedwater at the Inlet of Boiler ( in T/Hr )

Mc Mass Flow Rate of Reheat Steam (in T/Hr)

Es Enthalpy of Main Steam at the Outlet of Boiler (in Kcal/Kg)

Ef Enthalpy of Feedwater at the Output of Top Heater (in Kcal/Kg)

Eh Enthalpy of HRH Steam at the Outlet of Reheater (in Kcal/Kg)

Ec Enthalpy of CRH Steam at the Inlet of Reheater (in Kcal/Kg)

Output Output (in Kw)


Heat Rate Calculation -Jindal India Thermal Power Lim

Mass Flow Rate of Feed Water At the Inlet Enthalpy of Main Steam at the Outlet
of Boiler in T/hr. of Boiler in Kcal/kg
Mf Es

1830.588 810.7

1444.15 810.7

1087.977 810.7

1899.47 810.7

1503.062 810.7

1123.699 810.7

1918.109 810.7

1995.388 810.7

1946.979 810.7

1640.656 810.7

1827.274 813.3

1430.276 821.9

1058.089 829.9

2050 810.7

1762.752 810.7

1612.25 810.7

1876.195 810.7

1226 810.7
-Jindal India Thermal Power Limited

Enthalpy of Feed Water at the Output of Mass Flow Rate of Reheat Steam in
Top Heater in Kcal/kg T/hr.
Ef Mc

290.3 1553.374

272 1253.064

259.3 953.077

291.4 1550.46

276.8 1247.779

259.3 950.116

292.1 1564.442

294.6 1622.544

295.6 1640.481

174.9 1586.549

291.8 1546.683

277.1 1230.907

259.3 927.191

293.8 1613.855

235.3 1579.953

223.7 1285.76

290.7 1533.017

145.85 1182.482
Enthalpy of HRH Steam at the Enthalpy of CRH Steam at the Inlet of
Outlet of ReHeater in Kcal/kg ReHeater in Kcal/kg Heat Rate
(in Kcal/Kwh)
Eh Ec

858.6 727.5 1927.14

860.1 728.5 1964.31

861.7 728.9 2018.00

858.6 726.7 1984.83

860.2 727.4 2017.06

861.7 728.1 2073.73

858.5 726.7 2001.54

858.2 726.6 1975.32

858.1 727.2 1914.76

858.2 735.9 2061.94

858.6 729.2 1921.77

860.3 735.9 1942.37

861.9 742.4 1984.85

858.3 726.3 2036.35

858.3 731.7 2023.34

847.3 742.6 -

858.7 726.8 1963.04

861.2 721.05 -