You are on page 1of 58

Base Station Configuration

Management
ZTE University
Objectives

 Understand the base station configuration flow


 Master the base station equipment resource
configuration
 Master the base station radio resource
configuration
Contents

 Base Station Configuration Overview


 Configuration Management Initialization
 Base Station Equipment Resource Configuration
 Base Station Transmission Resource
Configuration
 Base Station Radio Resource Configuration
Overview

Equipment Transmissio Radio resource


resource n resource

eNodeB
configuration

ZTE Corporation. All rights reserved


Base Station Configuration Flow

Start

N
LTE sub-network available? Create LTE sub-network

Y
Create base station

Apply for Mutex right

Configure Base Station Equipment resource

Configure Base Station Transmission resource

Configure Radio resource

End

ZTE Corporation. All rights reserved


Contents

 Base Station Configuration Overview


 Configuration Management Initialization
 Base Station Equipment Resource Configuration
 Base Station Transmission Resource
Configuration
 Base Station Radio Resource Configuration
Configuration Flow

ZTE Corporation. All rights reserved


Starting the EMS Client

ZTE Corporation. All rights reserved


Creating an NE Agent

 Right-click the root


node of topology tree,
and from the prompt
drop-down menu,
select Create Object
> Basestation>
Multi-mode > MO
SDR NE Agent.

 On the Create MO
SDR NE Agent
interface, input the
related information of
the OMM server, and
click OK.

ZTE Corporation. All rights reserved


Starting an NE Agent

ZTE Corporation. All rights reserved


Creating a Subnetwork

ZTE Corporation. All rights reserved


Creating an NE
In the Configuration Management window, right-click the created
subnetwork and select Create NE.

ZTE Corporation. All rights reserved


Applying for the Mutually Exclusive Access

To prevent different clients


or different users to conflict
with each other during
mutual operation, the NE
management enables the
right restriction. After an NE
is created, to perform the
add, deletion, modification,
and view operations upon
this NE, you must apply for
the mutually exclusive
access first.

ZTE Corporation. All rights reserved


(Optional) Configuring System Parameters

ZTE Corporation. All rights reserved


Contents

 Base Station Configuration Overview


 Configuration Management Initialization
 Base Station Equipment Resource
Configuration
 Base Station Transmission Resource
Configuration
 Base Station Radio Resource Configuration
Equipment Resource Configuration Flow

Create operator Configure physical Configuration network


information resources transmission resources

ZTE Corporation. All rights reserved


Creating an Operator

In the Configuration
In the Managed Element
Management window, expand
tree, double-click Operator.
the NE and select Modify Area.

ZTE Corporation. All rights reserved


Creating an PLMN

In the configuration resource


tree, expand Operator and On the PLMN-List tab, click
double-click PLMN.

ZTE Corporation. All rights reserved


Creating a Baseband Resource Board

1. In the managed
element tree, double-
click Device.

2. On the Physical
View sub-tab of the
Rack Graph tab, right-
click the slot in which a
board is to be created
and select Add Board.
Notes: Based on BBU board planning,
repeat step 2 and step 3 to create the SA,
BPL or BPL1, and PM boards.
ZTE Corporation. All rights reserved
Creating an RRU

1. In the managed-
2. On the Physical View
element tree, double-
tab, click .
click Device.

ZTE Corporation. All rights reserved


BBU Board Introduction
ZXSDR B8300 TL200 Slot No.
When you create a rack, the 6(BPL9) 12(BPL5)
17(PM1)
system creates a CC board by 5(BPL8) 11(BPL4)
default, and other boards 4(BPL7) 10(BPL3)
16(PM2) 18(FA)
3(BPL6) 9(BPL2)
should be configured in
14(SE) 2 (CC2) 8(BPL1)
accordance with the actual 13(SA) 1 (CC1) 7(UCL)
requirement.
Note: In X(YZ), X is the slot No., Y is the board applicable in this slot, Z is
the slot priority when the board and slot are in an one-to-many
relationship.

Example

17(PM1)
11(BPL4)
10(BPL3)
The board is created in 16(PM2) 18(FA)
9(BPL2)
this sequence: PM > CC > 8(BPL1)
13(SA) 1 (CC1)
SA > SE > FA > UCI > BPL.
After determining the actual configuration of BBU, you need to
configure the related boards in the corresponding slots. In this example,
the boards are created in this sequence of PM*2 > SA > FA > BPL*4.
After the LTE (BPL) board is created successfully, the system
automatically creates optical ports.

ZTE Corporation. All rights reserved


Configuring the SNTP
In the managed-element tree, select System Parameter and
double-click Time Configuration.

ZTE Corporation. All rights reserved


Clock Source Parameter Configuration
1. In the managed-element tree, select Device >
B8200(1,1) > CC(1.1.1) (B8200 is a BBU type, and is
2. Click .
shown as an example) and double-click Clock Device
Set.

ZTE Corporation. All rights reserved


Power Module Configuration

ZTE Corporation. All rights reserved


Configuring the Baseband Board Attributes

ZTE Corporation. All rights reserved


Configuring the Optical Port Attributes of a
Baseband Board
In the managed-element tree, select Device > B8200(1,1) > BPLor BPL1
(B8200 is a BBU type, and is shown as an example) and double-click
Optical Port Device Set.

ZTE Corporation. All rights reserved


Optical Port Device Configuration
In the managed-element tree, select Device > B8200(1,1) > BPL or
BPL1 > Optical Port Device Set (B8200 is a BBU type, and is shown as
an example) and double-click Optical Port Device. The Optical Port
Device-List tab is displayed. There are three configuration records for
the optical port device, corresponding to the three optical ports of the
BPL board.

ZTE Corporation. All rights reserved


Configuring the RRU Attributes
In the managed-element tree, select Device > RRU and double-click
R8962 (R8962 is an RRU type, and is shown as an example).

ZTE Corporation. All rights reserved


RRU Optical Port Device Configuration
In the managed-element tree, select Device > RRU > R8962 >
Optical Port Device Set (R8962 is an RRU type, and is shown as an
example) and double-click Optical Port Device. The Optical Port
Device-List tab is displayed. There are three configuration records
for the optical port device by default.

ZTE Corporation. All rights reserved


Creating Optic Fiber RF Resource1
During the configuration, the matching relationship
between RRU and BPL is configured in accordance with the
following principle:

If there are several baseband boards and each baseband is connected


to one RRU, configure the one-to-one corresponding relationship
between the RRU RF resource No. and BPL slot priority No.
If there is only one baseband board and it is connected to several RRUs,
configure the one-to-one corresponding relationship between the RRU
RF No. and BPL optic port priority. The priority of optic port from top to
down is: OF0/optic port 0, OF1/optic port 2, and OF0/optic port 3.
If there are several baseband boards and the baseband boards are
connected to several RRUs or one RRU, consider the priorities of the
BPL and optic fibers both.

After configuring the RRU RF resource and RF antenna group,


you need to configure the optic RF resource, so that the BBU
baseband board and RRU can form a matching relationship.
ZTE Corporation. All rights reserved
Creating Optic Fiber RF Resource2

Relationship Between BBU Baseband Board and RRU/Cell

B8300 baseband board is connected to one RRU


6(BPL9RRU9 12(BPL5RRU5
CELL9) CELL5)
17(PM1)
5(BPL8RRU8 11(BPL4RRU4
CELL8) CELL4)
4(BPL7RRU7 10(BPL3RRU3
CELL7) CELL3) 18(FA)
16(PM2)
3(BPL6RRU6 9(BPL2RRU2
CELL6) CELL2)
8(BPL1RRU1
14(SE) 2 (CC2)
CELL1)
13(SA) 1 (CC1) 7(UCL)

Baseband is connected to several RRUs

[BPL-OF2-RRU3-CELL3][BPL-OF1-RRU2-CELL2][BPL-OF0-RRU1-CELL1]

ZTE Corporation. All rights reserved


Creating an Antenna Entity

ZTE Corporation. All rights reserved


Configuring an RF Cable

ZTE Corporation. All rights reserved


Configuring an Ir Antenna Group

ZTE Corporation. All rights reserved


Configuring a Fiber Cable

ZTE Corporation. All rights reserved


Contents

 Base Station Configuration Overview


 Configuration Management Initialization
 Base Station Equipment Resource Configuration
 Base Station Transmission Resource
Configuration
 Base Station Radio Resource Configuration
Transmission Resource Configuration Structure

ZTE Corporation. All rights reserved


Configuring the Transmission Resource

Physical Layer Port Configuration

IP Transmission Configuration

Bandwidth Configuration

Signaling and Business Configuration

Static Routing Configuration

OMC Channel Configuration

ZTE Corporation. All rights reserved


Configuring a Physical Layer Port
1. In the managed element
tree, select Transmission
2. Click + in the right
Network > LTE FDD >
pane.
Physical Hosting and double-
click Physical Layer Port.

ZTE Corporation. All rights reserved


IP Transmission ConfigurationConfiguring an
Ethernet Link
In the managed-element tree, select Transmission Network > LTE TDD
> IP Transport and double click Ethernet Link Layer.

ZTE Corporation. All rights reserved


IP Transmission ConfigurationConfiguring the IP
Layer
In the managed-element tree, select Transmission Network > LTE TDD
> IP Transport and double-click IP Layer Configuration.

ZTE Corporation. All rights reserved


Bandwidth ConfigurationBandwidth Resource
Group

 In the managed-element tree, select Transmission Network >


LTE TDD > Bandwidth Assignment and double-click Bandwidth
Resource Group.

ZTE Corporation. All rights reserved


Bandwidth ConfigurationBandwidth Resource

 In the managed-element tree, select Transmission Network >


LTE TDD > Bandwidth Assignment > Bandwidth Resource
Group and double-click Bandwidth Resource.

ZTE Corporation. All rights reserved


Signaling and Business ConfigurationSCTP
Parameters
 In the managed-element tree, select Transmission Network > LTE TDD >
Signaling and Business and double-click SCTP.

ZTE Corporation. All rights reserved


Signaling and Business ConfigurationDSCP
Mapping

 In the managed-element tree, select Transmission Network > LTE TDD >
Signaling and Business and double-click Service and DSCP Mapping.

ZTE Corporation. All rights reserved


Configuring a Static Routing
 In the managed-element tree, select Transmission Network >
LTE TDD > Static Route and double-click Static Routing
Configuration.

ZTE Corporation. All rights reserved


Configuring an OMC Channel

 In the managed-element tree, select Transmission Network >


LTE TDD and double-click OMC Channel.

ZTE Corporation. All rights reserved


Contents

 Base Station Configuration Overview


 Configuration Management Initialization
 Base Station Equipment Resource Configuration
 Base Station Transmission Resource
Configuration
 Base Station Radio Resource Configuration
Radio Resource Configuration Flow

Configuring LTE Configuring


TDD/FDD Global Baseband
Parameters Resources

Configuring a Serving
Configuring the S1AP
Cell

ZTE Corporation. All rights reserved


Configuring LTE TDD/FDD Global Parameters
In the managed-element tree, select Radio Parameter and double-click LTE TDD.

ZTE Corporation. All rights reserved


Configuring Baseband Resources
In the managed-element tree, select Radio Parameter > LTE TDD > Resource
Interface Configuration and double-click Baseband Resource.

ZTE Corporation. All rights reserved


S1AP Configuration
In the managed-element tree, select Radio Parameter > LTE TDD > Resource
Interface Configuration and double-click S1AP.

ZTE Corporation. All rights reserved


Configuring a Serving Cell1
In the managed-element tree, select Radio Parameter > LTE TDD and double-click
E-UTRAN TDD Cell.

ZTE Corporation. All rights reserved


Configuring a Serving Cell2

ZTE Corporation. All rights reserved


Configuring a Serving Cell3

ZTE Corporation. All rights reserved


Data Synchronization

After an eNodeB is configured


All-table in the network management
synchronizat system, the configuration data
ion is only saved in the database of
the back-end network
management system. Users
must perform synchronization
to update the configuration
data of the front-end eNodeB
to validate the configuration.
Data
synchronizat
ion
Record level All product
increment table
synchronizat synchronizat
ion ion

ZTE Corporation. All rights reserved


Synchronizing All Tables

ZTE Corporation. All rights reserved

You might also like