Professional Documents
Culture Documents
of Storage Tanks
2008 NZSEE
Conference
1 INTRODUCTION
In 1986 the NZ Society for Earthquake Engineering (NZSEE) published a comprehensive document
entitled Recommendations for Seismic Design of Storage Tanks. The document has been used
extensively in New Zealand, and has been widely referenced internationally, including by Eurocode 8.
The document remains one of the most comprehensive guidelines available for the seismic design of
storage tanks. The NZSEE study group has recently been working to revise the 1986 document to
bring the recommended seismic design loads in to line with the latest NZ Loading Code NZS 1170.
The completed revision of the document is soon to be published.
New Zealand practice for seismic design of steel storage tanks is generally based on US codes, mainly
Appendix E of API 650. During the 1980s a modified version of API 650 adapted for use in New
Zealand (SDPP) was used widely for seismic design of pertrochemical plants. In 1986 the NZSEE
Recommendations for Seismic Design of Storage Tanks was published.
Since the early 1990s various methods including API, SDPP and the NZSEE have been used for
design of steel storage tanks, and these methods gave significantly different requirements.
New Zealand Standard NZS 3106:1986 covers design of concrete water retaining structures including
seismic effects. The seismic design coefficients specified in that Standard are now out of date.
Recently issued legislative requirements for storage of hazardous products in New Zealand (HSNO)
permit the use of API 650 or NZS 1170.5 for seismic design. The revised NZSEE document is also
intended to be recognised by the HSNO regulations as an approved code of practice.
Procedures for the seismic analysis and design of storage tanks are generally based on the Housner
Paper Number 04
multi-component spring/mass analogy. The analogy allows the complex dynamic behaviour of a tank
and its contents to be considered as simple modes of response including a short period impulsive
mode, with a period of around 0.5 seconds or less, and a longer period convective (sloshing) mode
with periods up to several seconds. For most tanks the impulsive mode dominates the loading on the
tank wall and the convective mode dominates the wave height and required freeboard. The mechanical
spring/mass analogy for the assumed modes of vibration is shown in Figure 1.
Figure 1. Mechanical spring/mass analogy for impulsive and convective modes of vibration.
Damping levels for tanks have generally been assumed to be of the order of 2-5% for the impulsive
modes and 0.5% for the convective modes. The additional effects of radiation damping (i.e. energy
lost into the foundation) in reducing earthquake response can be considerable, providing equivalent
viscous damping levels of as much as 20-30%.
The 1986 NZSEE recommendations provided a detailed approach to seismic analysis and design for a
range of types of storage tanks. Practical design examples were included and detailed methods for
analysing the seismic behaviour of anchored or unanchored tanks were included.
The seismic loadings included in the document were based on early seismic hazard assessments for
New Zealand available at that time, however these are now considered to be well out of date. The
design method for steel tanks is an ultimate limit state approach, but it assumed no yielding or ductility
of tank elements is permitted.
Experience with use of this document in designing steel storage tanks has indicated that the
requirements were often significantly more conservative compared with design to the API 650
approach.
4 RECENT NEW ZEALAND SEISMIC DESIGN STANDARDS NZS 4203 AND NZS 1170
Since publication of the 1986 document there have been two major revisions to the loading standard
for buildings NZS 4203. In 1992 seismic loads in NZS 4203 were revised based on hazardbased
seismicity maps of New Zealand. Since 2004 a joint Australian and New Zealand Standard AS/NZS
1170 Design Loads for Buildings, has been introduced and is a means of compliance with the
performance-based NZ Building Code. The Standard now supersedes NZS 4203. NZS 1170.5 is the
section of the Standard that deals with seismic loads.
2
The design spectra in NZS 1170 are based on a comprehensive seismic hazard analysis using New
Zealand seismicity models and earthquake shaking attenuation criteria. NZS 1170 is a limit-state code
with the ultimate limit state based on strength design and serviceability limit state dealing with
damage and displacement control. Although NZS 1170 is not directly applicable to tanks, it has been
used as the basis for setting seismic loads for design of storage tanks, with a correction factor being
applied to better account for ductility and damping levels in tanks.
5 API 650
API 650 Appendix E has been widely used around the world for seismic design of steel storage tanks.
It covers the United States and a wide range of other locations around the world. A simplified analysis
of seismic effects including impulsive and convective modes and a working stress approach is used in
the code for checking stress limits in the tank shell.
Until recently the design loads for the most seismic region of the US were based on an impulsive
mode acceleration of up to a maximum of 0.24 g in the most severe seismic zone in US, together with
a simple overturning stability limit for unanchored tanks.
The 2006 edition of API 650 Appendix E is significantly changed, and is based on the following:
Seismic hazard maps and design spectra for the whole of the US (short period spectral
coefficients of up to 2.0 g are specified for earthquake shaking with a return period of 2,500
years).
The methodology allows use for locations outside the US, based on seismic coefficients
obtained probabilistic design spectra or peak ground acceleration values.
Force reduction factors are used to determine design seismic loads (e.g. 3.5 for unanchored
tanks).
Stress limits are working stresses with maximum stresses of up to 0.9 times yield stress.
An overturning stability limit is given for unanchored tanks.
Care is required in applying NZS 1170.5 loadings to API 650.
The NZSEE 2008 method includes the following principal changes to the 1986 document:
Seismic load for tanks is in accordance with NZS 1170.5:2004, the national loading standard
for buildings, including probabilistic hazard based seismic design spectra.
Adjustments are made for the effects of damping levels and ductility levels appropriate for
tanks.
Some limited ductility is permitted and is reflected in the force reduction of design loads.
The ultimate limit state design methodology is in alignment with other NZ structural design standards
and can also be interfaced with other international codes and design guides.
The horizontal seismic force acting on a tank, associated with a particular mode of response, is
calculated from the expression in Equations 1 to 3.
Vi = Cd (Ti ) mi g (1)
3
and Vi = horizontal base shear for mode i (impulsive, convective etc).
mi = equivalent mass of tank and contents responding in mode considered.
Cd(Ti) = horizontal design action coefficient for mode i.
C(Ti) = ordinate of the elastic site hazard spectrum for horizontal loading for the site
subsoil type, and the relevant mode. Obtained from NZS 1170.5 for tank
importance level.
kf(,i ) = correction factor for NZS 1170.5 elastic site hazard spectrum to account for
ductility and level of damping, refer Table 2.
Sp = structural performance factor, to be taken as 1.0.
Ch (Ti) = spectral shape factor for site subsoil type and relevant mode, from NZS 1170.5.
Z = seismic zone hazard factor, from NZS 1170.5.
Ru = return period factor for the ultimate limit state, from AS/NZS 1170.5 for tank
importance level.
N(Ti,D) = near fault factor, from NZS 1170.5.
= displacement ductility factor for horizontal impulsive modes. Taken as 1.0 for the
convective and vertical modes.
Ti = period of vibration of appropriate mode of response
i = damping level appropriate to mode of response.
This approach replaces the design loading section of the 1986 NZSEE document with loads from the
NZS 1170:2004 design spectra, with an additional correction factor for ductility and damping
appropriate for tanks.
Displacement ductility factors of either 1.25 or 2.0 are permitted for seismic design of tanks, as shown
in Table 1. Although not strictly ductile behaviour, certain modes of inelastic behaviour, such as base
uplift and elephants foot buckling of steel tanks, are assumed to be an equivalent ductile response. The
use of ductility is a departure from the 1986 Red Book approach and results in lower design loads.
4
Steel Tanks, t / R = 0.002
35
30 0.5
25
Damping Factor, %
1.0
20
0.3
15
1.5
10
2.0
H/R = 3.0
0
200 250 300 350 400 450 500 550 600
Shear Wave Velocity, m/s
Figure 2. Example damping for horizontal impulsive mode. Steel tanks t/R = 0.002.
1.8
1.6
1.0
0.8
0.6
0.4
0.2
0.0
0% 5% 10% 15% 20% 25% 30%
Damping
The seismic load derivation is based on the same approach used in NZS 1170 using Importance Levels
to reflect the significance of the facility and appropriate Return Period Factors. The Importance Level
is derived from considering the consequences of failure, based on separate consideration of life safety,
environmental risk, community significance and adjacent property value. Recommended
classifications of risk for each of these aspects can be found in the document. The Importance Level
used in determining the design load is then based on the worst of these considerations. Proposed
Importance Levels and Return Period Factors are given in Table 2.
Table 2. Importance Level and Return Period Factors to be used in application of AS/NZS 1170.
5
for buildings, with values of between 0.7 and 1.0. The use of Sp = 1.0 is specified for tanks in
recognition of their limited ductility capability.
7 COMPARITIVE EXAMPLES
The seismic loads specified by the NZSEE 2008 method are compared with the requirements of the
1986 NZSEE and API 650 (2003 and 2006) methods for several example steel tanks. Comparison is
also made with seismic loads required by the existing water retaining structures code NZS 3106:1986.
Details of the example tanks are summarised in Table 3.
8 SUMMARY
The 2008 NZSEE publication entitled Seismic Design of Storage Tanks is summarised. The document
updates the original 1986 document to be consistent with the current New Zealand structural loading
and materials standards. Several example tanks have been considered to compare the seismic design
loads required against other available methods.
6
ACKNOWLEDGEMENTS
The authors wish to acknowledge the financial assistance of the following industry sponsor
companies: New Zealand Earthquake Engineering Society, Mobil Oil New Zealand Ltd, Shell Oil
New Zealand Ltd, Caltex Oil New Zealand Ltd, BP Oil New Zealand Ltd, NZ Refining Ltd., Shell
Todd Oil Services Ltd, New Zealand Insurance Ltd.
The NZSEE members that prepared the 2008 document were: David Whittaker (Convenor), Dean
Saunders, Rob Jury, John Wood, Barry Davidson, Graeme McVerry and John Mason.
2.0 2.0
Case 1 1.76 Case 2
type: unanchored steel petrol tank type: unanchored steel petrol tank
Impulsive Coefficient (g)
1.08
1.0 1.0
0.74
0.69
0.60
0.47 0.48
0.5 0.36 0.5
0.0 0.0
NZSEE NZNSEE API 650 API 650 NZSEE NZNSEE API 650 API 650
2008 1986 2003 2006 & 2008 1986 2003 2006 &
NZS1170 NZS1170
2.0 2.0
Case 3 Case 4
type: unanchored steel petrol tank type: unanchored steel petrol tank
Impulsive Coefficient (g)
Impulsive Coefficient (g)
0.97
1.0 1.0
0.0 0.0
NZSEE NZNSEE API 650 API 650 NZSEE NZNSEE API 650 API 650
2008 1986 2003 2006 & 2008 1986 2003 2006 &
NZS1170 NZS1170
4.0 4.0
Case 5 Case 6
type: anchored steel petrol tank 3.36 type: anchored steel petrol tank
Impulsive Coefficient (g)
2.0 2.0
1.40
1.12
1.0 1.0
0.62 0.60 0.60
0.48 0.40
0.0 0.0
NZSEE NZNSEE API 650 API 650 NZSEE NZNSEE API 650 API 650
2008 1986 2003 2006 & 2008 1986 2003 2006 &
NZS1170 NZS1170
3.0 3.0
Case 7 Case 8
type: prestressed concrete water reservoir type: prestressed concrete water reservoir
2.5 location: Wellington 2.5 location: Auckland
Impulsive Coefficient (g)
Impulsive Coefficient (g)
1.5 1.5
0.0 0.0
NZSEE 2008 NZNSEE 1986 NZS 3106 NZSEE 2008 NZNSEE 1986 NZS 3106
Figure 4. Comparison of design impulsive mode bas shear coefficients for example tanks to various design
standards.
7
REFERENCES:
American Petroleum Institute. 2003. API 650 Welded Steel Tanks for Oil Storage.
American Petroleum Institute. 2006. API 650 Welded Steel Tanks for Oil Storage.
Environmental Risk Management Authority, Hazardous Substances (Dangerous Goods and Scheduled Toxic
Substances) Transfer Notice, (Amended) 08 August 2006.
Ministry of Works and Development, 1981. Recommendations for Seismic Design of Petrochemcial Plants.
New Zealand National Society for Earthquake Engineering, 1986. Recommendations for Seismic Design of
Storage Tanks.
New Zealand Society for Earthquake Engineering. 2008. Seismic Design of Storage Tanks (In Preparation).
Standards New Zealand. NZS 1170.5, 2004, Structural Design Actions, Part 5 Earthquake Actions.
Standards New Zealand. NZS 3106, 1986, Code of Practice for Concrete Structures for the Storage of Liquids.
Whittaker, D. and Jury, R.D. 2000. Seismic Design Loads for Storage Tanks. Proceedings 12th World
Conference on Earthquake Engineering, Paper Number 2376.