You are on page 1of 4

Seismic response of fire water tank FT-1101

Project: LPG Thi Vai


Seismic design parameters
Reference peak ground acceleration
agR = 0.0442 g (Appendix E, TCVN : 9386-2012)
with g= 9.81 m/s
Importance factor I = 1.25 (Appendix E, TCVN : 9386-2012)
Design ground acceleration
ag = I.agR = 0.05525 g
Ground type: D
Horizontal elastic response spectrum

Damping correction factor


(%)
0.5 1.35
: viscous damping ratio (%) 2 1.2
Parameters S, TB, TC, TD: refer to Table 3.2, TCVN : 9386-2012

Horizontal elastic response spectrum

0.30
0.25
0.20
0.15 = 0.5%
Se/g
= 2%
0.10
0.05
0.00
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0

T (s)

Prepared by Chu c Hi 1/4


Tank parameters:
Radius R= 10 m
Height of liquid H= 17.7 m
Equivalent thickness of tank wall
s= 0.012 m
Mass of tank wall mw = 1.16E+05 kg
Mass of tank roof mr = 5.92E+04 kg
Height of centre of gravity
hw = 9.8 m
hr = 19.81 m
Mass density of liquid
= 1000 kg/m
Mass of liquid m = 5560619 kg
Modulus of elastic of tank material
E= 2.E+11 N/m
Refer to table A.2 Eurocode 8 Part 4 for the following factor:
Cc
H/R Ci mi/m mc/m hi/H hc/H hi'/H
(s/m1/2)
1.77 6.141 1.480 0.728 0.272 0.444 0.723 0.525

Impulsive response Convective response


Timp = 0.222 s Tcon = 4.680 s
mi = 4045795.2 kg mc = 1514823.8 kg
hi = 7.86 m hc = 12.80 m
hi' = 9.30 m hc' = 13.28 m

Seismic Responses
Impulsive spectral acceleration with 2% damping ratio
Se(Timp) = 0.223 g
Convective spectral acceleration with 0.5% damping ratio
Se(Tcon) = 0.025 g
The total base shear
Q = (mi + mw + mr)Se(Timp) + mcSe(Tcon) = 9602 kN
The overturning moment above the base plate
M = (mihi + mwhw + mrhr)Se(Timp) + mchcSe(Tcon) = 79325 kNm
The overturning moment below the base plate
M = (mihi' + mwhw + mrhr)Se(Timp) + mchc'Se(Tcon) = 92256 kNm
Sloshing height
d = 0.84RSe(Tcon)/g = 0.21 m

Prepared by Chu c Hi 2/4


01

Prepared by Chu c Hi 3/4


hc'/H

0.750

Prepared by Chu c Hi 4/4