Professional Documents
Culture Documents
MEASUREMENT
Edited by
Amir Attari
Donald L.Klass
Institute of Gas Technology, Chicago, Illinois, U.S.A.
This volume contains papers presented at the first and second IGT symposia on natural gas measurement.
The first program was held on August 2628,1985 in Chicago to provide a forum for dissemination of
information on all aspects of calorific value measurement of natural gas. Bowing to popular demand,
however, selected papers on volumetric measurement of natural gas were also included in the second
program held April 30-May 2,1986 in Chicago to broaden its scope.
Speakers from the U.S. gas industry, U.S. Federal and academic thermochemical research centers, and
U.S. instrument manufacturers, as well as speakers from West Germany, The Netherlands, Japan, and
Indonesia presented papers.
The conference papers in this book are organized under several topics that reflect the original program
sessions of oral presentations. The topics of the first symposium (Natural Gas Energy Measurement, I) are:
Thermal Energy Measurement (papers 15), Calibration Standards (papers 610), Automated Energy
Measurement (papers 1115), and Energy Measurement Accuracy (paper 16). The general topics of the
second symposium (Natural Gas Energy Measurement, II) are: Measurement Fundamentals (papers 13),
Volumetric Measurement (papers 45), Thermal Energy Measurement (papers 614), and Field Applications
of Energy Measurement (papers 1520). Full texts of the papers are produced with minimal editorial
changes.
The most significant event that came to light at the first conference was the compilation and acceptance
of a single set of enthalpies of combustion for light hydrocarbons by the National Bureau of Standards and
the Thermodynamic Research Center of Texas A&M University. This news is a welcome development, in
that if these newly published thermochemical constants are generally adopted by the gas industry for use in
the calculation of calorific value (or other properties) of fuel gases from their compositions, it will help
alleviate a big source of confusion and ambiguity at the custody transfer points. We hope that these IGT
programs will spark an awareness of the need for standardized measurement practices and the eventual use
of a single system of units of measurement and reference conditions throughout the energy industry.
iv
The success of the two conferences in large measure was due to the efforts of the speakers and the
authors to whom we are especially thankful for giving their time, energy, and experience in providing the
high caliber of papers that were presented. We plan to continue Natural Gas Energy Measurement as a
series.
Amir Attari
Donald L.Klass
Institute of Gas Technology
TABLE OF CONTENTS
CALIBRATION STANDARDS
6 PREPARATION OF STANDARDS FOR GAS ANALYSIS 31
G.C.Rhoderick and E.E.Hughes
7 NEW STANDARDS FROM THE INSTITUTE OF GAS TECHNOLOGY 39
B.H.Solka and A.Attari
8 THE ROLE OF CALIBRATION STANDARDS IN THE ANALYSIS OF 46
NATURAL GAS LIQUIDS
S, L.Brandt
9 COMMERCIALLY AVAILABLE CALIBRATION GASES 55
D.P.Norris
10 COMPOSITE SAMPLING OF NATURAL GAS 70
vi
T.F.Welker
MEASUREMENT FUNDAMENTALS
1 CALCULATION OF THE HEATING VALUE OF NATURAL GAS FROM THE 142
PHYSICO-CHEMICAL PROPERTIES OF THE PURE COMPONENTS
K.N.Marsh
2 GAS FLOW MEASUREMENT: CALIBRATION FACILITIES AND FLUID 148
METERING TRACEABILITY AT THE NATIONAL BUREAU OF STANDARDS
G.E.Mattingly
3 CROSS REFERENCE SERVICE OF NATURAL GAS STANDARDS IN THE 167
UNITED STATES
J.C, Shapiro, G.R.Burkett and W.A.Crowley
VOLUMETRIC MEASUREMENT
4 NEW CONCEPTS IN GAS CALIBRATION 176
E.J.Dahn
5 MICROSTRUCTURE SENSORS FOR FLOW, DIFFERENTIAL PRESSURE AND 182
ENERGY MEASUREMENT
R.Higashi, R.G.Johnson, A.K.Mathur, A.N.Pearman and U.Boone
vii
ABSTRACT
There is a need today to improve the level of precision of our gas measurement practices. Our current
technology is some 50 years old. Over the past several years, our industry has committed millions of dollars
in research in the basic technology area. We are currently beginning to see the results of this research effort,
however, much more remains to be done. In the final analysis, research, standards and procedures will not
be enough. As an industry, were going to have to make a major technical commitment in this area. The
measurement engineer of tomorrow will need a sound base in fluid dynamics and mathematics with a little
computer science thrown in. Without that high degree of interest, well be unable to achieve an
improvement in precision.
Our topic: Gas MeasurementThe Need and the Reality, presents quite a number of challenges. The need
is relatively simplethere is a need today to improve the level of precision of our gas measurement
practices. Reality is an entirely different matter. Psychologists tell us that its a matter of personal
perception.
In that context, this personal perception approach, there are 3 concerns in the field of basic engineering that
impact us in our gas measurement practice:
1. The substitution of standards and procedures for judgement and responsibilityweve all used that
crutch. Back in our college days wed try to memorize how a problem was solved in the book,
substitute the numbers in the problem and turn the crank for an answer. This is really the substitution of
memory for brains (there is a difference). The approach has been compounded in recent times by the
legal professionyouve got to have standards to protect yourself from a lawsuit. On a broader scale,
government is continually promulgating standards in order to fit all of us into little nitches. Their own
bureaucracy is so effective, they have to impose it on the rest of us. The net effect of this is that the
2 GAS MEASUREMENTTHE NEED AND THE REALITY
successful engineer is the one who knows where it is in the book, not the one who can apply the
common sense and logic. Weve substituted standards and procedures for judgement and responsibility.
2. Engineers have become so involved with numbers that theyve lost touch with reality. Back in the
olden days the standard tool of the engineer was a slide rule. This would give him 3 significant
figures of accuracy which was generally within the required precision of the calculation. The slide rule
disappeared with advent of the hand held calculator; which in turn has been subplanted by the personal
computer. A 32 bit computer will give, say, 12 significant figures. This is great for number crunching,
but we have to step back from time to time and ask whether or not those 12 significant figures are
within the precision of our basic data. My personal observation is that we dont step back often enough.
We become so enraptured with the numbers and our ability to manipulate them that we lose sight of
what their real significance is.
3. Life has become so complicated and knowledge so broad that as individuals we tend to concentrate in
specific areasthis is the you cant see the forest for the trees syndrome, or its correlary you cant
see the trees for the forest. Sometimes in working a problem (the forest) we fail to look at its elements
(the trees) to determine their impact on the solution.
We can perhaps place these points into perspective by looking at the needs and the realities of gas
measurement. The need here, to improve the level of precision in gas measurement, relates to changes that
have taken place in the market over the last ten years. What was applicable in the 60s is questioned in the
80s. Yet from a measurement standpoint our technology is more in keeping with the 30s. Today we deal with
a measurement technology that is fifty years old. A technology that produces results that are +/ 0.5%. Or to
place this in engineering termsa technology that will produce results to three significant figures. Common
practice, however, marries computer techniques to our calculation and we regularly produce billings to nine
or more significant figures. We fail to recognize that a $1,000 bill is really +/ $5 and a $1,000,000 bill is +/
$5,000,
This technology lag is nothing new. On the other hand, it was only with the major escalation in the price
of natural gas and other related hydrocarbons that occurred in the late 70s that our industy really displayed
an interest in the precision, or accuracy of our volume measurement. Actions were initiated to address these
concerns. Any advance in technology requires two thingstime and money. We dont really have enough of
either one. On the other hand, what we are commiting is begining to produce results.
Over the past several years, our industry has committed millions of dollars in research in this basic
technology area. Specific programs have been adopted and funded by the American Gas Association, the
American Petroleum Institute, the Gas Research Institute, vendors, the National Engineering Laboratory of
Great Britain, Gasunie in Holland, Ruhr Gas in Germany, Gaz de Franze and probably several others that
dont immediately come to mind. This work has been done in cooperation with the National Bureau of
Standards at both the Boulder and Gaithersburg facilities, the University of Oklahoma, Texas A&M, the
Colorado Engineering Experiment Station, Inc., Southwest Research and Gulf Research.
Weve seen a whole new emphasis on Standards as a direct result of these concerns:
1. ANSI/API 2530 (A.G.A. Report No. 3) covering orifice metering of natural gas and other related
hydrocarbon fluids, was revised 1 years ago and in May of 1985, was approved by ANSI.
2. A.G.A.Transmission Measurement Committee Report No. 7 covering turbine meters was published
earlier this year and provides a sound basis in that area.
3. ISO 5167, the International Standard on orifice metering, has been with us now for about 5 years.
3
4. ASME recently approved a Standard covering Measurement of Fluid Flow in Closed Conduits with
Orifice, Nozzle and Venturi. This has been proposed to ANSI.
From our industry standpoint, the first two of these help. They dont really improve the level of precision
available, but they do provide a sound foundation for future change. The ISO and ASME Standards tend to
add confusion in this area, but on the bright side, underscore the importance of a consistent technical
approach to large volume measurement. These particular methods provide two alternate means of evaluating
orifice meters. The answers are different but in most cases within the precision mentioned earlier. The key
point, is they do not provide any improvement in that precision.
From a political standpoint, weve seen a far broader interest in gas measurement. Up through the 60s
this was almost the exclusive province of the American gas industry. Today we see a high level of involvement
from producer groups (GPA and API), plant operators (ASME), affiliated organizations (ISA), district
heating organizations, consumer advocates (through state utility commissions), government (BPL and
DOE) and international organizations (ISO, OIML, GERG and others). Unfortunately some very pointed
questions are being askedquestions for which we, as an industry, have no immediate answers.
An International Measurement Symposium, under the joint sponsorship of many of the organizations
previously mentioned, both national and international, is scheduled to be held in the fall of 1986. The
purpose of this is both to discuss the current state of the art, but on a more critical level to bring together
these varied interests into a cohesive unit that can address shared concerns on a technical basis.
Our industry has something to share. The research efforts that have been underway for the past several
years are at long last beginning to bear fruit:
1. The supercompressibility project being conducted by University of Oklahoma, under the sponsorship
of GRI, is releasing their initial report covering a far broader spectrum of gases that have been
applicable to our old NX-19 evaluation. Contracts have been entered into for publishing an application
guide with current thinking that this will be released this fall as A.G.A. Transmission Measurement
Committee Report No. 8Compressibility and Supercompressibility of Natural Gas and Other
Hydrocarbon Gases. This is really a tremendous step as our industry regularly works with gases well
outside of the applicable range of NX-19.
The value of this work goes well beyond measurement. The compressibility data will provide a
better basis for compressor design and testing. Reservoir engineers should find the expanded range of
particular value. Line pack calculations will be more precise. This work is really a key step in basic
knowledge.
2. The NBS Boulder flow disturbance work, again funded by GRI, is still in the early stages, but is already
providing some answers. Papers presented at the 1985 A.G.A. Operating Section conference provide
some real insight into current concerns and future efforts in this area. This work is directed not only to
identifying the impact of these disturbances, but to means of mitigating those impacts.
3. The API orifice data project is well underway and we hope to have some of the early data reports
available during 1985. This work includes orifice data on water, viscous fluids and natural gas.
4. The NBS Boulder data (funded by GRI), which was released in 1983, has been expanded with work at
CEESI and a contract has been negotiated with Gulf Research for further data acquisition. All of this
experimental data should give us a sound basis for a consensus orifice flow equation of higher precision
that we enjoy today.
4 GAS MEASUREMENTTHE NEED AND THE REALITY
These varied programs were set out to address specific problems. They are advancing technology in limited
areas. In the broad over-view we find that similar programs are underway in the European Economic
Community and by other industry organizations on a national level. In that context, our approach is
disjointed. Even today, there are a number of defined concerns that demand solution but are not being
adequately addressed: we are not taking advantage of the technology that exists in other industries and has
application; we do not have a real means of determining what is accurate and perhaps most importantly,
we need a comprehensive program to both direct our actions in this vital area and to communicate our
concerns to others in order to broaden the base of activity.
It was in this context that an industry solicitation was made among individuals having an active interest in
the measurement field. Those contacted were asked to respond with items that sould be considered as
elements of this comprehensive measurement plan. The many thoughts and ideas returned were combined
into twenty specific elements under the generic headings of: 1. Basic Research, 2. Laboratory Needs, 3.
Hardware Needs, 4. Instrumentation, 5. Standards and 6. Associated Relationships.
Respondents were then asked to prioritize these elements in the context of their perception of industry
needs. Seven of the twenty were set out for immediate action with four others being categorized as high
priority. Finally, respondents were asked to provide specific actions in each of the seven areas that would
address the concerns and move our industry toward solutions. The response here provided the basis for a
plan that was approved this spring by the A.G.A. Operating Section. The plan combines the thoughts and
ideas of many people and appears to address the concerns as we identify them today. It is recognized as an
initial approach. All of the listed items are important. The priorities only attempt to direct our limited
resources to areas that appear to have the greatest immediate return for our industry. Hopefully by
articulating the broad list, we can gather support from others and work toward solution in these many areas.
The seven primary elements of this plan include:
1. We need to expand our knowledge of the physical properties of natural gas, synthetic gas and the
hydrocarbon constituents of these gases. This knowledge must include the influence of contaminants in
various quantities, together with the impact of pressure, temperature, etc.
2. We must continue the work to develop an expanded base of research quality data on orifice flow
coefficients. This work is currently underway but its completion is essential to several other aspects of
the broad measurement plan.
Turbine and rotary meters have immediate application in many areas with wider rangability and to
some degree less bother that the orifice meter. We cant loose sight of the fact that there are hundreds
of thousands of orifice meters in operation. The replacement of most of these is not practical from
either an economic or a physical standpoint. We have no choice but to improve the precision of this basic
method.
3. We need to expand our knowledge of how measurement, by whatever meter is employed, is influenced
by external factors and what corrective measures can be taken to mitigate those influences. Key items here
include approach conditioning, expansion factor, instrument connections, instrument locations,
pulsation, type of instrumentation, transducer response, etc.
4. We need to develop an independent qualified flow test facility with basic measurements traceable to the
National Bureau of Standards. This facility should be operated under the sponsorship of the gas
industry. It must be capable of evaluating metering devices, both new and existing and provide
documented data on performance characteristics at various temperatures, pressures, flow rates,
Reynolds Number, etc.
5
Several independent facilities exist that have partial capability in this area. The individual and
collective limitations dictate the need for a single comprehensive facility. This sounds simple but really
isnt. It will take a great deal of effort to make this a reality.
5. We must place additional emphasis in the area of real time measurement. We must know today the
quantity of gas being used today. This involves marrying computer technology to our gas measurement
concepts and the development of on site techniques to correct for pressure, temperature and gas
constituents.
6. We need an acceptable secondary standard that will provide results traceable to the National Bureau of
Standards. The device must be capable of being used in situ for field calibration or as a shop test
facility that will evaluate a meter under its operating conditions.
This is really an extension of the transfer proover concept to a broad range of flow. With the new
speed of sound data the critical flow nozzle may have application. With recovery sections they have low
pressure loss and multiple nozzles can provide for a wide range of flow and pressure.
7. We should develop a better understanding of the basic fluid dynamics of gaseous flow through various
meters through the development of computer models that can be verified by non-intrusive devices. The
computer models could result in an entirely new generation of measurement devices.
The plan itself, with all twenty elements and details on action plans, has been published as an Engineering
Technical Note by the A.G.A. Operating Section. Copies are available direct from A.G.A. for those with an
interest.
Fortunately, several of the items in the plan are covered, at least in part, by the current research efforts.
This research must be completed and expanded programs implemented if we are to improve our technology
in this area. Improve it, we must. If we as an industry, dont accomplish this, it will be done for us by
others. Such action could be to our serious detriment.
The need thento improve the level of precision of our gas measurement practicesbecomes far more
complex as we break it into its specific parts. The statement encompasses a broad goal. As we break it into
its elements we can examine its complexity.
The reality is that the needs have been identified and work is under way to accomplish the goal. What is
being attempted here is to improve the level of precision by almost a full order. This cannot be
accomplished by standards and procedures alone. As an industry, were going to have to continue a major
technical commitment in this area. Were going to have to understand what our base measurements really
are and the impact of gravitational force, barometric pressure and temperature. Were going to have to apply
a better understanding of the nature of our instruments. Do they really measure absolute values of pressure
and temperature as we say they do? Where does reality fit in, in terms of the precision of the instrument
itself and the precision of the calibration? Do we really know the nature of the fluid were measuring, or its
changes with time? Do its changes due to outside influences have a significance in our measurement
process?
The measurement engineer of tomorrow will not be able to substitute standards and procedures for
judgement and responsibility. He will have to have a broad understanding of the values and the significance
of the data hes working with. And finally, hell have to understand both the forest and the trees. We wont
need a botonist, but we will need an individual with a sound base in fluid dynamics and mathematics, with a
little computer science thrown in. Without that base, your company will suffer the economic consequences.
NATURAL GAS PROPERTIES CALCULATIONS FROM
COMPOSITION
Kenneth R.Hall, Ph.D.
Professor of Chemical Engineering
Director, Thermodynamics Research Center
Texas A&M University
College Station, Texas 77843
ABSTRACT
Let us assume for purposes of this paper that we can know the composition of a gas from some suitable
measurement. It is then possible, in principle, to calculate pertinent properties such as: heating value,
relative density, compressibility factor. Unfortunately, as often happens in practice, these supposedly
unambiguous calculations become clouded by accepted procedures, misconceptions, misguided regulations.
The discussion in this paper attempts to dispel the misconceptions and to clarify the accepted procedures.
As for the regulations, it is only possible to wish that they would not always choose the path of maximum
irrationality and to try to perform the calculations in the least offensive (technically) manner possible. The
calculations described in this paper reflect those suggested in GPA Standard 217285. However, this paper
contains considerable amplification and discussion of the techniques.
INTRODUCTION
While we usually consider the composition of a natural gas as a known, it is really at best approximately
known because of measurement errors. In this paper, let us assume that we do in fact know the composition
and, ignoring composition errors, discuss how to approach properties calculations from this knowledge.
Various standards in the natural gas industry address this issue, among them are GPA-2172, ANSI-2530
and ASTM D-3588. This paper closely follows GPA-2172 but contains considerable amplification.
The primary properties of interest are, compressibility factor, relative density (or more specifically
relative molar mass) and heating value. In the following discussion, we examine definitions,
misconceptions, recommended calculation procedures, shortcut approximations and sources of uncertainty.
7
DEFINITIONS
The definitions of the pertinent properties are not necessarily totally unambiguous. The reasons are some
unfortunate federal regulations and some misguided standard practices. The adopted definitions are
consistent with GPA-2172 which is the most recent standard published covering this topic.
Compressibility Factor
The compressibility factor is the ratio of the ideal gas density to the real gas density when both are at the
same temperature and pressure. The primary function of compressibility factor is to indicate the deviation
of real gas behavior from that of the ideal gas.
Relative Density
The relative density is the ratio of the density of the gas at its temperature and pressure to that of dry air at
its temperature and pressure. The relative density is primarily a means to establish the molar mass of the
gas.
Heating Value
Heating value refers to the total energy transferred as heat in an ideal combustion reaction at base temperature
and pressure. For net heating value, the water formed in the combustion appears as vapor in the products; for
gross heating value, the water formed in the combustion appears as liquid in the products.
COMPRESSIBILITY FACTOR
The compressibility factor is usually the most convenient form in which to express the equation of state P=P
(T,p). From the definition, it is
(1)
where Z is compressibility factor, p is density per mass, M is molar mass, P is pressure, R is the gas
constant, T is temperature and super * denotes ideal gas. At conditions of temperature and pressure near
ambient, the truncated virial equation of state adequately represents the volumetric behavior of natural gas
(2)
In Equation 2, B is the second virial coefficient for the natural gas mixture and is a function only of temperature
and composition
(3)
where x is mole fraction and n is the total number of components. In Equation 3, the Bii are pure virial
coefficients and Bij are interaction virial coefficients. For natural gas components (except He and H2) at
near ambient conditions, the virial coefficients are negative. The Bii and Bij are functions only of
temperature.
8 NATURAL GAS PROPERTIES CALCULATIONS FROM COMPOSITION
Several equations exist for estimating values for Bii and Bij. GPA-2172 contains one that is particularly
convenient over the temperature range which includes all base condition temperatures used
for natural gas. Invariably, these expressions require a computer for efficient use. However, on a computer,
they are rather simple to calculate.
For hand calculations, a simplification provides very reasonable values. The basic assumption is that the
interaction virial coefficient is the geometric mean of the pure virial coefficients.
(4)
RELATIVE DENSITY
Having the compressibility factor expression allows us to calculate relative density, G:
(6)
where subscript a refers to air. We should note immediately that the sole function of the relative density is to
provide the molar mass of the gas. Reference to air is an artifact associated with devices used for field
measurements; it is not necessary but it is practical.
If the gas and air have identical temperatures and pressures, Equation 6 simplifies to
(7)
The value of Z , often assumed to be unity, is actually about 0.9996. While 0.04% error may not be of much
concern, assuming the temperatures and pressures to be identical can introduce serious errors unless the
measurement instrument specifically addresses this assumption.
Should the air and gas be in ideal gas states, the values of Za and Z are exactly unity and Equation 7
reduces to
(8)
Therefore, the molar mass of the gas is
(9)
Knowledege of the composition eliminates the necessity for this measurement because
(10)
and the pure molar masses are available. Division of Equation 10 by Ma produces an expression for ideal
relative density.
9
(11)
HEATING VALUE
The primary thing to remember about heating value is that it is an ideal gas property. It reflects energy
transfer in an ideal combustion reaction
(12)
(13)
where * denotes ideal gas and denotes liquid. Clearly, the difference between net and gross is the ideal
enthalpy of vaporization of the water, , which is slightly larger than the enthalpy of vaporization,
. Data for such reactions is invariably at 25 C and in SI units.
The enthalpy of combustion data usually appears on an amount (per mole) basis. For a mixture, the value
is
(14)
To convert the enthalpy of combustion per mole to a per mass basis requires division by the molar mass
(15)
Multiplication of the enthalpy of combustion per mass by the ideal gas density provides the enthalpy of
combustion per volume
(16)
For a dry gas, the enthalpy of combustion is the negative of the heating value. Wet or saturated gas presents
a question of interpretation.
(18)
where nw denotes the moles of water. Therefore, the correct analysis of the gas requires adjusting the
various mole fractions. The total moles of dry gas is 1 while the total moles of wet or saturated gas is
(19)
The mole fractions of dry gas are
(20)
therefore the mole fractions of wet or saturated gas are
(21)
Thus, to obtain corrected mole fractions, multiply by one minus the mole fraction of water and then use the
xi(cor) in the equations for enthalpy of combustion.
If it is not possible to determine the mole fraction of water empirically, it is common practice to assume
Raoults law for the saturated gas
(22)
where is the vapor pressure of water at the temperature selected (for practical purposes the base
temperature). This expression assumes either a) ideal gas vapor, ideal solution liquid, liquid volume
independent of pressure or b) all non-idealities cancel identically. It is probably a reasonable assumption for
saturated natural gas between 0 and 25C and near 1 atmosphere.
For net heating value at a given base temperature and pressure, the correction term 1-xw is simply a
constant multiplier . However, a problem arises when using gross heating value because technically
water has a gross heating value from the reaction
(23)
equal to the ideal enthalpy of vaporization. Thus, to calculate the gross heating value per volume for a wet or
saturated gas involves and additive term.
(24)
(25)
Of course, custody transfer is on a gross basics by law or agreement. The heating value is input data to
calculate . Various procedures are possible. The preferable, but never used, procedure uses
(27)
where is the molar flowrate. It is simple to convert the calculation to a mass basis
(28)
or to volumetric bases
(29)
(30)
where is the mass flowrate, is the ideal gas flowrate and is the real gas flowrate. Summarizing,
Equations 26, 27, 28 and 29 become
(31)
Equation 31 illustrates some misconceptions. Use of molar flowrate, mass flowrate or ideal gas flowrate is
actually simpler than using real gas flowrate to calculate . An objection might be that flowmeters, notably
orifices, produce , This is true, but with exactly the same information it is possible to calculate , or with
slightly less uncertainty. In the case of and , it is not even necessary to establish a base pressure because
and are independent of pressure while is not.
A more serious misconception is that division of the ideal heating value, , by Z produces the real
heating value. This is not true. Division of by Z produces which is the required value in calculation of .
It is possible but impractical to calculate the real heating value and from it the real energy released,
However, Q is not the actual energy released. is really a weighting factor in Equation 25, is equally as
valid as weighting factor as would be is much simpler and less ambiguous to calculate than .
CONCLUSIONS
We have examined calculation procedures to obtain compressibility factor, relative density and heating value
from composition analysis. In each case, we have tried to illustrate common misconceptions and to
demonstrate rigorous procedures where possible.
For compressibility factor, we have seen that the commonly used summation factor approach relys upon a
not unreasonable but unfounded assumption. We have noted that the whole purpose of relative density is to
provide the molar mass of the gas. While most field instruments measure relative density, it is possible to
devise instruments which measure M directly.
The heating value is the object of the most mystique. A logical and rational basis for heating value is to
use the net value per mole with molar flowrate. The next most logical route is to use net value per mass with
mass flowrate; then net value per volume with volumetric flowrate; then gross value per mole with molar
flowrate; gross value per mass with mass flowrate; gross value per volume with volumetric flowrate. All the
above procedures assume a dry gas calculation. The order of preference repeats on a lower level for
saturated gas calculations. Finally, we must conclude that the least rational and most cumbersome
calculation is the saturated, gross, volumetric basis. However, this is precisely what we must do because of
historic reliance upon the Cuttler-Hammer calorimeter, existing contacts, and misguided federal regulations.
Finally, we have noted that division of the ideal heating value per volume (which is the commonly
tabulated value) by compressibility factor does not produce the real heating value per volume. It only
permits use of the real gas flowrate in calculating .
12 NATURAL GAS PROPERTIES CALCULATIONS FROM COMPOSITION
GPA 217285 utilizes all the procedures discussed in this paper. It also permits the calculations at any
temperature between 0 and 25C (60F=15.56C) and for any pressure up to about 2 atmospheres.
HEATING VALUES OF COMPONENTS OF NATURAL
GAS
D.Garvin and E.S.Domalski
Chemical Thermodynamics Data Center
National Bureau of Standards
Gaithersburg, MD 20899
R.C.Wilhoit, G.R.Somayajulu and K.N.Marsh
Thermodynamics Research Center
Texas A&M University
College Station, TX 77843
ABSTRACT
New recommendations for the heating values of components of natural gas are reported. These are based on
a reassessment of the available experimental data. The new recommendations are valid for the temperature
range from 0 to 25C and for pressures up to about one atmosphere. The sources of the data are indicated
and factors considered in the reassessment are presented. Heating values of components of natural gas are
known to about 0.02 to 0.04 percent.
INTRODUCTION
For the gas industry, the most important physical property of natural gas is its heating value. This value can
be determined by calorimetry or by calculating the value from a knowledge of the composition of the gas
and the heating values of the pure components. Except for the most careful of calorimetric measurements,
the value obtained by calculation is more accurate.
A typical example is an instrument that measures the composition using a gas chromatographic technique
and then computes the heating value. For direct calorimetric measurements, it is also necessary to know the
heating values of the major components of natural gas, although the dependence is indirect. Calorimeters
used in the industry are calibrated by burning samples of natural gas of known heating value supplied by
IGT. These heating values are determined calorimetrically at IGT in instruments calibrated against a
reference sample of high purity methane, the heating value of which has been certified by NBS Armstrong [1],
This certified heating value is calculated from the composition of the sample and the heating values of the
components. Thus the field measurement is both traceable to NBS and to the heating values of the
components.
14 HEATING VALUES OF COMPONENTS OF NATURAL GAS
We have updated these heating values. This has been a joint project of two groups of thermodynamicists
who specialize in the evaluation of thermodynamic data. The new values take into account all of the
currently available data and are applicable to the entire range of standard temperatures and pressures used in
the gas industries of the world: 273.15 to 298.15 K (0 to 25 C), 0.1, 0.101325 and 0.10156 MPa (1 bar, 1
atm and 14.73 psia). They differ only slightly from values previously recommended, but probably have a
smaller systematic bias. In addition, careful attention has been paid to the question of the uncertainties to be
assigned to the data. They supersede the values given in Armstrong and Domalski [3], Armstrong and Jobe [2],
Domalski [6], the TRC Thermodynamic Tables 1982 [37], GPA 214577 [11] and related publications.
These recommended data have been prepared for the International Group of Importers of Natural Gas
(GIIGNL) and the (U.S.) Gas Producers Association (GPA) and will appear in their manuals and standards
[12,21]. The recommendations will also be submitted to the American Society for Testing and Materials and
to the International Standardization Organization for their consideration. It is our hope that the same
numbers can be used for heating values where ever natural gas is bought and sold.
Emphasis is placed in this paper on the data for the properties of the pure compounds that are components
of natural gas. How these properties are combined to produce heating values for natural gas mixtures at
appropriate standard conditions is the subject of another paper at this symposium and will not be reviewed
here. Instead, the required data will be specified, their sources indicated and examples given of the data
selection process.
(The calculation of properties of mixtures is also treated in detail in GPA 2172 [13] and Armstrong and
Jobe [2]. The latter also includes substantial material on background issues related to the specification of
heating values.)
THERMODYNAMIC PROPERTIES
Several physical properties are combined to produce the heating values at the standard conditions used in
the gas industry. The most important ones are:
Of lesser importance are the properties of the pure compounds in the real gas state. These are used to
calculate volumes needed to interpret flow measurements and to correct ideal- to real-gas enthalpies. Only
simple equations of state are required. For pressures up to about one atmosphere, these PVT data can be
represented by the second virial coefficients of the pure components and their interaction coefficients with
methane.
Heating Values
The selected heating values for the hydrocarbons from methane through the hexanes are given in Table 1.
These are for the complete reaction at constant temperature and pressure of the gaseous hydrocarbon with
15
gaseous molecular oxygen to form gaseous carbon dioxide and liquid water, that is they are gross calorific
values or higher (superior) heating values.
Table 1. Ideal Gas Heating Values for the C1, to C6 Paraffin Hydrocarbons, at Four Reference Temperatures. The
second decimal place is not significant, but is provided as an aid to rounding in calculations on mixtures.
CH/kJ.mol1
Compound 298.15 K 288.71 K 288.15 K 273.15 K
25 C 60 F 15 C 0C
methane 890.65 0.37 891.53 891.58 892.99
ethane 1560.69 0.25 1562.06 1562.14 1564.34
propane 2219.17 0.45 2221 .99 2221 .10 2224.01
n-butane 2877.40 1 .00 2879.63 2879.76 2883.82
iso-butane 2868.20 1.00 2870.45 2870.58 2874.20
n-pentane 3535.77 0.46 3535.84 3538.60 3542,89
iso-pentane 3528.83 0.58 3531.51 3531.68 3562.98
neo-pentane 3514.61 0.50 3517.27 3517.43 3521.72
n-hexane 4194.95 0.67 4198.05 4198.24 4203.23
2-methylpentane 4187.32 1 .00 4190.43 4190.62 4195.61
3-methylpentane 4189.90 1.00 4193.03 4193.22 4198.24
2,2-dimenthy butane 4177.52 1 .00 4180.63 4180.83 4185.84
2,3-dimethyl butane 4185.28 1 .00 4188.41 4188.60 4193.63
Auxiliary Data.
The thermochemical data for auxiliary substances at 298.15 K have been taken from the CODATA Key
Values for Thermodynamics [4], the reference base recommended for use in accurate work. Values at other
temperatures are derived using enthalpy differences as indicated above, except for water, for which the
enthalpy differences are consistent with the new NBS/NRC Steam Tables [16]. These are shown in
Table 2. Molar masses are calculated from the IUPAC 1981 Atomic Weights [17]. The value for the gas
constant, R=8.31448 J/(mol.K)1, which is needed in the calculation of volumes, is from the set that is
currently being recommended to CODATA by its Task Group on Fundamental Constants [35]. Thus all of
these data are up-to-date and internationally recognized.
Evaluation of Data.
The selection of the enthalpy of combustion data is outlined here in order to show the factors that are
involved. A more detailed report is in preparation. In some cases molecular structure correlations have been
used to help select from among discordant experimental values.
Methane. In 1931, F.D.Rossini determined the enthalpy of combustion of methane [28]. His work
outclassed all earlier measurements for precision of the heat measurement, analysis of the sample, the
determined completeness of combustion by weighing the water produced. An adequate correction was made
for the main impurity, carbon monoxide. These experiments, together with Rossinis earlier measurements
of the enthalpy of combustion of hydrogen in essentially the same apparatus have been the basis for most
recommended values since that time. It is difficult to fault them. The scatter of the six determinations is
shown on the left side of Figure 1. Rossini rejected the highest point, on sound statistical grounds.
In 1972 Pittam and Pilcher [24] remeasured the enthalpy of combustion of methane using the same
method (flow calorimetry) but with a much purer sample and a better analytical method (weighing the
CO2). Their six determinations are shown on the right side of Figure 1. This is a better measurement, but the
scatter in the data is similar to that in the study by Rossini; methane is very difficult to burn completely in a
calorimeter [33]. When the two data sets are considered together neither stands out, and it is no longer
certain that the point rejected by Rossini can be dropped. In the new assessment, the recomended value is an
average of all twelve points.
17
Figure 1. Comparison of the measurements of the enthalpy of combustion of methane made by Rossini [28] and by
Pittam and Pileher [24] and average values using different numbers of points.
Ethane and Propane.For both of these substances the measurements of Pittam and Pilcher [24] have been
selected, in preference to those of Rossini in 1934 [29]. This choice was made because the former used an
improved method, had purer gases and obtained more regular differences between enthalpies of combustion
in the series of compounds methaneethanepropane butane.
Butanes. Three studies on n-butane have been reported: Rossini [29], Prosen et al. [25] and Pittam and
Pilcher [24]. They are of similar quality, and the selected value is the average, without weighting, A larger
uncertainty is assigned to the selection compared to those reported by the authors.
For iso-butane, two calorimetric studies, Prosen et. al. [25] and Pittam and Pilcher [24] and two
isomerization equilibrium results, Scott [32], and Pines [23], are in moderate agreement. The four values
have been averaged. Rossinis value, reported in 1935 [30], is not in agreement and has been discarded.
Pentanes. There are three pentanes: n-pentane, 2-methylbutane, and 2,2-dimethylpropane. Calorimetric
measurements have been made on one or more of them by Rossini [29], Roth and Pahlke [31], Prosen and
Rossini [27], Pilcher and Chadwick [22] and Good [14]. There also are gas phase isomerization data for 2-
methylbutane measured by Pines et. al. [23] and reinterpreted by Scott [32]. We have adopted the selections
made by Good [14], which give priority to his very careful measurements,
Hexanes. There are five hexanes: n-hexane, 2-methylpentane, 3-methylpentane, 2,2-dimethylbutane and
2,3-dimethylbutane. For n-hexane there are three combustion measurements, all on the liquid, Jessup [18],
Prosen and Rossini [27] and Good and Smith, [15]. These are in reasonable agreement. The results of Good
and Smith [15] are selected, on the basis of improved technique and sample purity. The liquid phase value is
corrected to the gas phase using enthalpy of vaporization data [Majer, 20] and an adjustment to the ideal gas
state.
The data for the isomers of n-hexane introduce additional complications. Four types of data are used. (1)
Enthalpies of combustion which have only been measured relative to n-hexane and only for the liquids
18 HEATING VALUES OF COMPONENTS OF NATURAL GAS
[Prosen and Rossini, 26]. In effect, these are measurements of the enthalpies of isomerization. (2)
Equilibrium measurements on the distribution of the isomers in the gas phase, 294365 K [Evering and
DOuville, 10] from which more enthalpies of isomerization can be derived, using (3) statistical mechanical
thermal functions for the gases, and (4) correlated trends in enthalpies of formation among the aliphatic
hydrocarbons [34]. These represent a smoothing of data that takes into account much more than the hexanes.
The calorimetric, equilibrium and correlation results are in reasonable agreement for 2- and 3-
methylpentane, but not for the 2,2- and 2,3-dimethylbutanes. For 2- and 3-methylpentane, the calorimetric
results have been adopted. For the 2,2- and 2,3-dimethylbutane, an average of the calorimetric, equilbrium
and correlation data has been adopted. The recommended values carry appropriately large uncertainties. We
would be pleased to see these compounds remeasured.
REFERENCES CITED
1. Armstrong, G.T.; Calculation of the Heating Value of a Sample of High Purity Methane for Use as a Reference
Material; Nat. Bur. Standards Tech. Note 299 (1966).
2. Armstrong, G.T.; Jobe, T.J., Jr.; Heating Values of Natural Gas and its Components; Nat. Bur. Standards
Report NBSIR 822401 (1982), Armstrong, G.T.; Jobe, T.L., Jr.; Heating Values of Natural Gas and its
Components: Conversion of Values to Measurement Bases and Calculaton of Mixtures; in Stationary Gas
Turbine Alternative Fuels, ASTM STP 809, J.S.Clark and S.M.DeCorso, Eds.; American Society for Testing and
Materials, Philadelphia, (1983) pp. 314334.
3. Armstrong, G.T.; Domalski, E.S.; Minor, J.I.; Standard Combustion Data for the Fuel Gas Industry; American
Gas Association 1972 Operating Section Proceedings, Arlington, Va., pp D-74 to D-88 (1972).
4. CODATA Task Group on Key Values; CODATA Recommended Key Values for Thermodynamics 1977;
CODATA Bull. No. 28 (1978); J. Chem. Thermodyn.; 10, 903906 (1978); Idem, draft final report (1985).
5. Cutler-Hammer Co., Milwaukee, Wise., Gas Measurement and Mixing Equipment; pg R1-1 (4/1/1978).
6. Domalski, E.S.; J. Phys. Chem. Reference Data; 1, 221277 (1972).
7. Dymond, J.H. Smith, E.G.; The Virial Coefficients of Pure Gases and Mixtures: A Critical Compilation;
Oxford University Press, (1980).
19
8. Eiseman, J.H.; Potter, E.A.; J.Res. Nat. Bur. Standards; 58, 213226 (1957).
9. Electronic Associates, Inc., West Long Branch, N.J.; ENCAL Energy Information Systems; (1983).
10. Evering, B.L.; dOuville, E.L.; J. Am. Chem. Soc.; 71, 440445 (1949).
11. Gas Processors Suppliers Association, Physical Constants of Paraffin Hydrocarbons and Other Components of
Natural Gas in Engineering Data Book GPA 214577; (1977).
12. Gas Processors Suppliers Association, Physical Constants of Paraffin Hydrocarbons and Other Components of
Natural Gas in Engineering Data Book GPA 214585; (1985).
13. Gas Processors Association; Calculation of Gross Heating Value, Relative Density and Compressibility Factor
for Natural Gas Mixtures from Compositional Analysis; draft of GPA 2172 (1985).
14. Good, W.D.; J.Chem. Thermodynamics; 2, 237244 (1970).
15. Good, W.D.; Smith, N.K.; J.Chem. Eng. Data; 14, 237244 (1969).
16. Haar, L.; Gallagher, J.S.; Kell, G.S.; NBS/NRC Steam Tables; Hemisphere Publ. Corp., Washington (1984).
17. Holden, N.E.; Martin, R.L.; Pure Appl. Chem.; 55, 11191136 (1983).
18. Jessup, R.S.; J. Res. Nat. Bur. Standards (U.S.); 18, 115128 (1937).
19. Knowlton, J.W.; Rossini, F.D.; J.Res. Nat. Bur. Standards (U.S.); 43, 113115 (1949).
20. Majer, V.; Svoboda, V.; Hala, S.; Pick, J.; Coll. Czech. Chem. Communications; 44, 637651 (1979).
21. Mann, D., editor; LNG Measurement. A User Manual for Custody Transfer, Nat. Bur. Standards, in preparation
(1985).
22. Pilcher, G.; Chadwick, J.D.M.; Trans. Faraday Soc.; 63, 23572361 (1967).
23. Pines, H.; Kvetinskas, B.; Kassel, L.S.; Ipatieff, V.N.; J. Am. Chem. Soc.; 67, 631637 (1945).
24. Pittam, D.A.; Pilcher, G.; J. Chem Soc.; Faraday Trans. I, 68, 22252229 (1972).
25. Prosen, E.J.; Maron, F.W.; Rossini, F.D.; J. Res. Nat. Bur. Standards (U.S.); 46, 106112 (1951).
26. Prosen, E.J.; Rossini, F.D.; J. Res. Nat. Bur. Standards (U.S.); 27, 289310 (1941).
27. Prosen, E.J.; Rossini, F.D.; J. Res. Nat. Bur. Standards (U.S.); 36, 269275 (1944).
28. Rossini, F.D.; J. Res. Nat. Bur. Standards (U.S.); 6,3749 (1931), 7, 329330 (1931).
29. Rossini, F.D.; J. Res. Nat. Bur. Standards (U.S.); 12, 735750 (1934).
30. Rossini, F.D.; J. Res. Nat. Bur. Standards (U.S.); 15, 357361 (1935).
31. Roth, W.A.; Pahlke, H.; Z. angew. Chem.; 49, 618619 (1936).
32. Scott, D.W.; J. Chem. Phys.; 60, 31443169 (1974).
33. Skinner, H.A.; Private communication; (1982).
34. Somayajulu, G.R.; Zwolinski, B.J.; J. Chem. Soc. Faraday II; 72, 22142224 (1976)
35. Taylor, B.; Cohen, E.R.; Private communications; (198384).
36. TRC Thermodynamic TablesHydrocarbons, Thermodynamics Research Center, College Sta., Tx., 232(i.
200); 232(1,20j)v, loose leaf, extant 1985.
37. TRC Thermodynamic TablesHydrocarbons, Thermodynamics Research Center, College Sta., Tx., 232(1,
200)p; 232(1.20j)p, Oct. 31 (1982).
EFFECT OF C6+ HYDROCARBONS ON DEWPOINTS AND
HEATING VALUES
Richard F.Bukacek
Institute of Gas Technology
ABSTRACT
It is shown that irreversible condensation of calibration gases due to trace amounts of C6+ hydrocarbons can
be important to the calibration of calorimeters but is not likely to be significant in the calibration of devices
for composition measurement.
Background
Gas samples in general and calibration gases in particular are subject to the possibility of condensation
during storage and transit. Gaseous hydrocarbon mixtures, whether natural gases or man-made mixtures,
will typically contain traces of the heavier hydrocarbons. These trace materials can raise the hydrocarbon
dew point of the mixture and thereby alter the heating value of the sample if the condensation process is not
fully reversible. With the high market value for natural gases, consideration of third order effects on
composition can become important and several questions arise with regard to traces of the C6+
hydrocarbons.
1. What constitutes a trace amount that need not be accounted in determining a heating value?
If irreversible condensation takes place in a calibration sample and trace components are present:
2. At what temperature would a significant change in composition of the vapor phase be observed?
3. Is it important to characterize the C6+ hydrocarbon traces before estimating their effect on a calibration
gas?
21
Method of Study
In this work, three hydrocarbon mixtures were studied.
In all tables, the higher heating values reported are calculated by the method of IGT Bulletin 32 and
NGPA publication 214571. The Soave/Redlich/Kwong equation of state was used to calculate the
dewpoints of these mixtures and the equilibrium composition of their vapors at temperatures below the dew
points.
The dew point of these mixtures was calculated at several pressures. On the basis of 1 mole of mixture, 0.
0001 mole of trace component was added and the mole fractions of the resulting mixture were then
calculated. To see the effect of different trace materials, the trace 0.0001 mole was nC6, nC8 or nC10. That
is, the trace components were characterized by assuming their properties those of a single component, either
nC6, nC8 or nC10.
An iterative process was used to establish the temperature at which a mixture with the trace component
produced, at equilibrium, a vapor phase with a heating value 0.05% less than the heating value of the base
mixture. That is, for Gas 1, the temperature was found at which vapor phase heating value was 1043.47
BTU/SCF with trace components present at the level of 0.01%. By this procedure the effect of irreversible
condensation can be shown and the range of temperatures in which it might occur is illustrated. The basis for
this procedure is as follows: If a calibration gas contains trace components that cause condensation that is
irreversible, the liquid formed will extract components from the vapor phase that are intended for
calibration. If the the most important purpose of calibration is to establish heating values, then the most
appropriate criterion of significant change is the effect on heating value measured or calculated.
Results
Results of computation are summarized in Tables 2 through 11. In these tables T* is the temperature at
which the vapor phase heating value is 0.05% smaller than that of the base mixture. Hb is the heating value
of the base gas, Ht is the heating value of the mixture that includes the trace material, and H* is 0.9995
(Hb). DP (base) is the dew point of the base mixture, and DP (trace) is the dew point of the mixture which
includes the trace. All temperatures are degrees Celsius, and pressures are atmospheres.
22 EFFECT OF C6+ HYDROCARBONS ON DEWPOINTS AND HEATING VALUES
Examination of Tables 2, 3 and 4 shows that for Gas 1, cooling to until the heating value of the vapor is 0.
9995 that of the base gas brings the temperature quite near the dew point of the base gas. When heating
value is calculated from composition it seems unlikely that gases with very low dew points like Gas 1 would
suffer a heating value loss as large as 0.05% because the base dew point is below the temperatures a sample
is likely to experience, and totally irreversible condensation seems unlikely.
Although trace components characterized by nC10 or higher hydrocarbons can raise the dew points can be
raised to summertime air temperatures, the temperature at which calibration components would significantly
move to the liquid phase is much lower. However, cooling to 25 C with nC10 as trace yields a vapor phase
with a heating value 1.27 BTU/SCF smaller than that of the starting material, a loss of 0.12% in the heating
value of the mixture that includes the trace. Thus a distinction must be made between a gas sample used to
calibrate a calorimeter and one use to calibrate a device measuring composition.
Tables 5, 6 and 7 summarize results for Gas 2.
23
As expected, the effect of increasing molecular weight of the trace components is to raise the dew point of
the mixture. Also in accord with the results for Gas 1, although dew points can be raised to summertime air
temperatures by the presence of traces characterized by nC10 and heavier, the effect of irreversible
condensation on composition is apt to be very small. For example, suppose a sample of Gas 2 is stored at 12
atmospheres and trace materials characterized by nC10 are present in amount 0.01% . From Table 7 we see
even if this sample was cooled to 10 C and irreversible condensation occurred, this gas used to calibrate a
chromatograph would be accurate to within 0.7 BTU/SCF, 0.05%, for calculation of heating value. If this
same gas were used to calibrate a calorimeter, the maximum possible reduction of heating value due to
irreversible condensation would be from 1147.91 to 1146.59 BTU/SCF, a loss of 1.3 BTU/SCF or 0.12%.
Tables 8, 9 and 10 summarize results for Gas 3.
The pattern of condensation for Gas 3 is very like that of Gases 1 and 2. Shown in tables 8, 9 and 10 are the
fraction of sample that has condensed at T* and the heating value of the equilibrium liquid, H1. It is of
interest to note that at T* the moles condensed are 4 to 5 times greater than the amount of trace material,
even though T* is always greater than the dew point temperature of the base gas. This illustrates the point made
earlier that the non-trace components dissolve in the liquid formed. Thus, the heating value of the liquid is
always much less than that of the trace materials because the lighter hydrocarbons dissolve in the liquid
formed and dominate its composition.
It will be observed that in all cases, T* approaches the dew point temperature of the base gas. That is,
even when the dew point temperature is raised greatly by trace components and the liquid formed is
predominantly materials from the base gas, the most important fact is that the amount of liquid formed at
temperatures above the dew point is quite small so long as the amount of trace materials is small. This is
illustrated in Table 11 where the amount of trace material is doubled to 0.02%.
It can be seen from Table 11 that the now 10 or 12C greater than the dew point The amount of liquid
formed at T* is still seems unlikely that calibration of devices measurement would be affected by irreversi
under the usual conditions of storage and Also, the heating value with the trace nC adds 1.43 BTU/scf to the
heating value of the base gas, 0.13% of its heating value.
The effect of characterizing hydrocarbon on the contribution of trace components to calorimetric
measurements is shown in Table 12.
It is clear that if a gas is to be used for calibration of a calorimeter, then it will be necessary to determine the
amount of trace components present and characterize their heating value if accuracy in heating value is to be
better than 0.1%.
Conclusions
The results of this work suggest the following:
1. It is important to distinguish between the uses made of calibration gases: Trace components summing
to 0.0156 are not likely to affect calibration of devices for measuring composition so long as the gas
free of trace components would not have reached its dew point temperature before use. For gases used
to calibrate calorimeters it will be important to determine the amount of trace components and
characterize their heating value if accuracy of the order of 0.1% in heating value is to be obtained.
2. The dew point of the base gas is a fair measure of the temperature at which irreversible condensation
would significantly affect a gas used to calibrate a device for measuring gas composition.
3. The possibility of irreversible condensation in gases used for calibration of devices for measuring
composition should not constitute a significant problem so long as the dew point of the base gas is
below the temperatures the gas is likely to experience during storage and transit, and the total of trace
components are present in amount of the order 0.01%.
EFFECT OF WATER VAPOR ON HEATING VALUE
Robert J.Rau
Division Measurement Manager
Transcontinental Gas Pipe Line Corporation
Baton Rouge, Louisiana 70806
ABSTRACT
This paper discusses the basic principles, laws and methods used to calculate heating value and the effects of
water vapor on these calculations. Methods shown include volumetric corrections as well as heating value
corrections using the IGT method.
Introduction
Today, this particular subject that has shifted somewhat to a back burner due to Order 93 not being put into
effect. Some specific contracts and companies are still doing this.
Water, in a natural gas pipeline, is and has a detrimental effect on various items. Some of these items are:
a. Hydrate formulation
b. Corrosion and internal corrosion
c. Accumulation of liquid water
d. Medium for solids movement.
The above items caused varied problems such as inaccurate measurement, flow rate interruption, equipment
repair and failure, loss of capacity, loss of control of pressure and instituting a corrosion protection plan of
high cost. As we all know, this causes loss of revenue and added operating costs.
27
Gas Sampling
Gas sampling is probably the most important thing that can affect the water determination results. Errors in
sampling could be a major contributing factor to either high or low results. A probe is necessary to get a
good representative result. The four main considerations in a sampling system design are:
where
W=mole percent of water vapor
Vp=vapor pressure of water at dew point temperature of the mix.
P1=total pressure on the volume psia.
This condition holds true at low pressure but has some deviation at higher pressures. This can be shown
by the following example.
Basic Data
A water vapor graph shows a content of 18.0#/MMCF. An established value is that 1 lb/MMCF=21.0181 cu
ft.
28 EFFECT OF WATER VAPOR ON HEATING VALUE
Therefore
where
Pw=pressure of water vapor (psia)
Pt=total pressure psia
Vw=volume of water vapor SCF
Vt=total gas volume SCF
Sample Problems
Dew point temperature=55 at 200 psig
From vapor pressure tablePw=.2130
2. Also, a common factor used for calculation showed 1 Ib of water at 14.73 psia and 60 equals 21.0181
cu ft. Therefore utilizing the standard manner of stating water content used by the gas industry then
3. Several different concepts must now come into play to utilize the water content. These concepts are:
When gas is not dehydrated, it is assumed to be saturated. Under these conditions, the volume calculation
can be factored to give a monthly average pressure and temperature, thus making correction easy.
So far, the methods discussed have utilized volume corrections that can be subtracted from measured
volumes but IGT developed an empirical method that corrects dry Btu basis to wet basis. This formula is as
follows:
where
1. Gas Temp=78F
Gas Press=500 psia
Btu=1020 dry @ 14.73 psia
1.
2.
D. Water Content
E.
F. Corr. Btu=1020.99886=1019 Btu corrected for water vapor af sat. gas at flowing conditions.
G. MMBtu=BTUcorrMCF/1000 with same press. base.
The major items that must always be considered so that errors in payment for Btu1 s do not occur can be
summarized as follows:
1. Always have the Btu on the same basis as volume. If Btu dry volume must be dry and vice versa.
2. Always have Btu and volume on the same pressure basis.
The following may be used as a guideline in summarizing Btu conversion from wet to dry. Most
calorimeters record Btu/cu ft at 14.7346 psia and 60F saturated with water vapor. The following
corrections need to be made.
3. If all water were taken out of saturated gas, the dry Btu would increase by factor of 1.0177.
4. In some cases, 7#/MMCF is considered dry by contract and an adjustment must be made for more than
7#.
A.
B.
C. An example of this calculation is
Calorimeter meas. Btu = 1005 Btu/cu ft (Sat)
Press. Base=15.025 psia
Contract water content 7#/MMCF
Actual water content 54#/MMCF
Delivered Btu=
Table 1 shows that the major item to watch in use of Btus for calculation is the different bases involved. In
short use oranges with oranges and apples with apples, and not oranges with apples.
References
1. R.N.Curry, Btu/Water Vapor Content Adjustment, 1980 American Gas Association Fall Meeting.
2. W.F.Barker, Determination of Water Vapor Content and Correcting for Its Effect on Volume and/or Btu
Determination. AGA Transmission Conference, 1981.
3. Gas Processors Association Technical Reference Bulletin 18181, Technical Standards Book, 1981.
PREPARATION OF STANDARDS FOR GAS ANALYSIS
G.C.Rhoderick and E.E.Hughes
Center for Analytical Chemistry
National Bureau of Standards
Gaithersburg, Maryland 20899
ABSTRACT
A primary standard is prepared by an absolute method with the gravimetric method being the preferred
technique. The basic technique involves weighing minor and major components into a cylinder. This basic
method can be modified to prepare samples at very low concentrations (parts per trillion) and containing
very specific and complex mixtures such as hydrocarbons. The uncertainty in the preparation procedure
may be determined by preparing a family of primary standards and intercomparing those standards by
analysis. As will be illustrated, it is very important to have standards which are very close and bracket the
concentration of the unknown in question. This is especially important when analyzing natural gas. In this
case, two methods may be used to determine the concentration of methane in natural gas. However, one
method will lead to a much lower uncertainty and thus, a lower uncertainty in the BTU value of the natural
gas.
INTRODUCTION
A standard is a material which allows a measurement to be made in such a way that there exists a pathway
between the measurement and one of the fundamental units of measurement. A Standard Reference
Material (SRM), issued by the National Bureau of Standards, is such a material. Through the use of
standards any two independent measurements may be compared providing each has a traceability pathway
to the same fundamental unit of measurement. The pathway may be through the use of an absolute standard
and a precise method of measurement or an absolute method of measurement alone.
In the case of gases there are few absolute methods which are applicable and the usual approach to
standardization is to use a standard which is compared to the sample by use of a precise method of
intercomparison. Standards for gas analysis may be prepared by mass, pressure or volume, all of which are
32 PREPARATION OF STANDARDS FOR GAS ANALYSIS
ultimately calibrated by mass. The most direct and accurate method is by mass (gravimetry) in which each
component is separately weighed into a gas cylinder. Preparation of standards by pressure is fast and
somewhat less accurate than gravimetry and is further complicated by uncertainties in the corrections for the
non-ideality of gases and gas mixtures. Standards prepared by volume are generally less accurate.
EXPERIMENTAL
Gravimetric Preparation
There are three major factors which contribute to the error of a gravimetric standard. These are: 1) weighing
errors, 2) errors in the assessment of the purity of reagents and 3) instability of the mixture in the container.
The first two sources of error can be minimized by careful attention to the details of the weighing process
and by rigorous analysis of the reagents. The last can only be observed experimentally.
requiring 0.5 g of the minor component weighable to 0.00001 g results in an error of only 0.002% in
weighing.
Stability of Mixtures
The next consideration is stability. There are two types of stability: 1) short term which considers adsorption
and absorption which occur on the interior surface as soon as the gas is admitted to the cylinder and 2) long
term which involves slow reactions between the components or between the container (+H2O) and a
component. To test for short term stability, the sample is analyzed as soon as it is prepared. Then some of
the sample is transferred to a new or treated cylinder and the contents of this cylinder is then analyzed. If the
measurements for the two cylinders agree within the precision of the method of intercomparison then
stability is assumed. When determining long term stability, a set of primary standards is prepared and the
sample is compared to the standards. Then at some time interval, say 3 months, a fresh primary standard is
prepared and the sample and all standards are compared. If the sample is within 0.5% of the original value
and the primary standards agree to within 0.2%, then stability of the sample may be assumed.
intercomparison is 0.090.17 ppm. Summed in quadrature these errors total about 0.20.3 ppm or about 0.
1% relative for a 300 ppm sample.
filings to keep glass out of the cylinder, are attached to the cylinder valve and a piece of tubing of 1.6 mm
i.d. and about 30 mm long is attached to the nipple. The capillary tube containing the
organic sample is then fitted into the tubing and results in a tight enough fit to prevent room air from being
pulled past the tube. The cylinder valve is then opened and the capillary tube is broken by manual force on
the end nearest to the valve. The tube is heated slightly in order to vaporize the organic liquid at which
point it is pulled into the cylinder by the vacuum. After all the material has been vaporized the other end of
36 PREPARATION OF STANDARDS FOR GAS ANALYSIS
the capillary tube is broken and room air is allowed to flush any residual organic material into the cylinder.
As many as nine tubes, each containing a different organic component, have been added to a single cylinder
by this technique. The cylinder is then weighed to determine the amount of air introduced, A matrix gas,
nitrogen, is then added to the cylinder. Typically a standard will contain about 4200 grams of nitrogen
matrix gas. The balance is readable to 1 gram, thus the error in weighing the matrix gas is about 0.02%.
Thus the controlling factor for weighing error lies in the weighing of the organic material.
Blank cylinders have been prepared in which no organics were introduced but room air was pulled into
the cylinder to atmospheric pressure. The blank cylinder was then pressurized with nitrogen and analyzed to
determine if any detectable impurities were introduced into the cylinder by this technique. No organic
impurities were detected, with the limit being 0.05 ppb for benzene which results in a maximum error due to
impurities in the matrix gases of 0.5% for a standard at 10 ppb.
Several gravimetric standards containing benzene in the 5100 ppb concentration range were prepared
and then intercompared. The data were then plotted, concentration versus area and correlated by linear
regression. The mean percent difference of the calculated and expected concentrations was determined to be
0.9%. That value takes into account all the errors in weighing as well as any systematic errors, such as any
loss of the organic material during the transfer to the cylinder which can not be estimated. This value should
be larger than the estimated uncertainty of the gravimetric standards and it is a better estimate of the uncertainty
of the gravimetric standards. Taking all the other errors such as the imprecision of replicate analysis of a
sample and the error of intercomparing a sample to the standards, the total uncertainty of a typical benzene
sample at this level is about 2.0% relative.
standards. The concentrations and uncertainties were calculated and then the total concentration and
uncertainties were calculated for those compounds minus the methane. The methane was then calculated
simply by subtracting the total concentration for the components from 100, The uncertainty for the methane
was calculated by summing all the individual uncertainties. Since these uncertainties represent the maximum
and we have determined the concentration and uncertainty of all components present in the unknown, we
can use the total uncertainty of all the compounds as the uncertainty in the methane value. Thus the
concentration for methane as determined by difference is 90.640.06% (0.07% relative, table 3). This
method is valid only if the sample is analyzed for other impurities and those impurities are taken into
account in the total value.
The response for the methane in the unknown was ratioed to each primary standard with the results
giving us a range of values from 90.10% to 90.96%, or about 1% relative differences. Let us consider that
the natural gas industry would like to determine the heating value (in BTU) of natural gas to about an
uncertainty of 0.5 BTU. Then with such a range of values between standards, 1%, the uncertainty of the
methane in this case would be about 9 BTU. If we determine the concentration by difference, the same
concentration for methane is obtained but the uncertainty that can be applied is substantially different: 90.64
+0.06%. In terms of BTU this would result in an uncertainty of 0.6 BTU.
CONCLUSIONS
Primary standards may be prepared with very good accuracy and very low uncertainties. By modifying the
basic method for preparing gravimetric standards, very complex and specific mixtures can be prepared. It is
possible to prepare mixtures at very low concentrations, with the limiting factors being the uncertainty that
can be tolerated and the sensitivity of the instrument or detector to be used for analysis.
It is very important that, when making primary standards for the analysis of an unknown, the
characteristics of the instrument, such as linearity, be considered. Generally, standards that bracket the
38 PREPARATION OF STANDARDS FOR GAS ANALYSIS
concentration of the unknown to approximately 1% are sufficient. This can be seen with the methane in
natural gas. The individual standards, ranging from 75 to 100%, when ratioed against the unknown gave a
range of concentrations of 1%. This possibly shows the error in the preparation of the standards, a slight
detector non-linearity, or detector saturation over this concentration range. Thus, the difference method for
determining the methane is the more suitable method for determining the concentration. This method also
results in a much lower uncertainty in the concentration, which in turn shows up in the BTU uncertainty of
the natural gas: 0.6 BTU compared to 9 BTU by direct analysis.
BIBLIOGRAPHY
Schmidt, W.P. and Rook, Harry L., Preparation of Gas Cylinder Standards for the Measurement of Trace Levels of
Benzene and Tetrachloroethylene, Analytical Chemistry, 55(2): 290294 (1983).
Rhoderick, George C., Cuthrell, William F. and Zielinski, Walter L. Jr., A Gravimetric Technique for the Preparation
of Accurate Trace Organic Gas Standards, Quality Assurance in Air Pollution Measurements, 239246, 1985.
KEY WORDS
gravimetric, primary standard, absolute method, intercomparison, traceability pathway, Standard Reference
Material
NEW STANDARDS FROM THE INSTITUTE OF GAS
TECHNOLOGY
Bruce H.Solka
Senior Analytical Chemist
and
Amir Attari
Associate Director, Chemical Research Services
Institute of Gas Technology
Chicago, Illinois 60616
ABSTRACT
Since 1961 the Institute of Gas Technology (IGT) has provided the gas industry with natural gas standards
of certified heating value and specific gravity for calibration of calorimeters and gravitometers,
respectively. The establishment of this program at IGT was the result of an earlier project initiated by
A.G.A. in cooperation with the National Bureau of Standards (NBS), This program was recently expanded
at IGT with the support and the initiative from the Gas Research Institute (GRI) to produce additional
natural gas standards including a gas chromatographic calibration standard gas.
INTRODUCTION
For the past 20 years, the Institute of Gas Technology (IGT) has provided the gas industry cylinders of
standard gas with certification of heating value and specific gravity of the contents. These cylinders have
been widely used in to calibrate their measurement instruments. During this 20 year period, however, users
have seen many changes in the requirements of their natural gas characterizations.
One significant change has been the increased utilization (and hence, measurement) of fuel gases having
heating values higher than the nominal 1000 Btu/SCF. Another change is the growing interest in obtaining
detailed compositional analyses of natural gas by routine gas chromatography (GC).
These developments have resulted in industry demands for reliable calibration standards for gas quality
measurements by GC. We at IGT have been made aware of this demand by increasing number of inquiries
from our current certified gas customers. As a result of these inquiries, in 1981 we mailed a questionnaire to
55 of the largest customers of the present program. This questionnaire addressed their anticipated use of
reference standard mixtures for gas chromatographic analysis of natural gas. Of the 31 respondents, 80%
40 NEW STANDARDS FROM THE INSTITUTE OF GAS TECHNOLOGY
were using GC at that time. Satisfaction with available standards was mixed. A clear majority desired NBS
traceability of standards as well as calorimetric verification of the heating value of the GC standard mixture.
The Gas Research Institute (GRI) also became aware of industry interest in new reference standard
mixtures certified by an independent agency. As a result, in August of 1984, GRI initiated the present
program at IGT with the ultimate goal of supplying the gas industry with a series of NBS traceable
calibration gases.
This talk is a summary of the present status of that program. The programs goal is to make available
several types of calibration standards to the gas industry by the end of 1985. These include a GC calibration
mixture with direct NBS traceable certification of composition and similarly traceable calorimetric
calibration standards with heating values in range of 800 to over 1200 Btu/SCF.
Table 1. COMPOSITION OF VARIOUS NATURAL GAS BLENDS (Dew Point Diagrams Appear in Figure 1)
------------------------Mole %--------------------------
Components /Sample 1 2 3 4 D (IGT)
Methane 70.55 90.58 88.73 90.65 90.65
Ethane 8.98 3.50 3.50 3.50 4.00
Propane 5.95 1.00 1.00 1.00 1,00
41
------------------------Mole %--------------------------
Components /Sample 1 2 3 4 D (IGT)
i-Butane 3.02 0.50 0.40 0.50 0.30
n-Butane 2.98 0.50 0.40 0.50 0.30
i-Pentane 1.00 0.15 0.15 0.15 0,10
n-Pentane 1.00 0.15 0.15 0.15 0.10
neo-Pentane -- 0.05 0.10 -- --
n-Hexane -- 0.05 0.05 0.05 0.05
n-Heptane -- 0.01 0.02 -- --
n-Octane -- 0.01 -- -- --
Helium 0.46 -- -- -- --
Nitrogen 4.95 2.50 2.50 2.50 2.50
Carbon Dioxide 1,09 1.0 3.00 1.00 1.00
Propylene 0.02 -- -- -- --
Key to Sample Numbers:
1: NGPA calibration gas from Phillips Petroleum
2, 3, and 4: Suggested by gas industry sources.
D: Gas composition selected by IGT for the forthcoming GC calibration gas.
heating value for calibration standards in the range of 800 to 1200 Btu/SCF. However, the criteria of
stability still requires a dew point consideration. Calorimetric analysis also consumes several orders of
magnitude more gas volume than GC analysis. Thus a calorimeter standard is normally compressed to near
2000 psig in a 1-A size cylinder in order to deliver a volume of about 225 SCF to the user.
Table 2 lists the compositions and heating values of several mixtures which were considered for these
standards. Figure 2 illustrates the SRK. dew point vs pressure curves for these mixtures. It can be seen that,
while the 812 Btu/SCF gas (mixture B) has a dew point temperature of 144F, the 1261 Btu/SCF gas
(mixture 5) approaches the 5F dew point region. Thus the mixture represented by curve C, a 75%
methane, 25% ethane blend with a heating value of 1185 Btu/SCF was chosen to be as near 1200 Btu/SCF
as possible and yet maintain a reasonably low dew point temperature of 26F/.
Certification Process
Sequence of Events Leading to Certification. Figure 3 diagrams the overall sequence of activities leading to
delivery of IGT certified calibration standards with NBS traceability. At this time, the four primary standard
mixtures have been analyzed and certified by NBS.
We are currently formalizing the protocol for certification of the GC calibration standard gas at IGT. The
traceability of these certified standards to the NBS primary standard will be the analysis of each cylinder
containing the certified gas on a GC system which will be calibrated on a daily basis with the NBS primary
standard. Protocol has not yet been established but our experience with the long-standing calorimetry
standard problem will serve as a guide. In that program a cylinder is tested on three separate days, using two
separate calorimeters which are calibrated daily with an NBS primary standard. The results of the three runs
must agree to within 1 Btu before the cylinders contents are considered certifiable.
42 NEW STANDARDS FROM THE INSTITUTE OF GAS TECHNOLOGY
Figure 1. HYDROCARBON DEW POINT DIAGRAMS FOR SEVERAL NATURAL GAS BLENDS, AS
PPEDICTED BY SRK EQUATION-OF-STATE
We do anticipate offering two types of GC standards; a small cylinder with composition certification only
and a larger cylinder with composition certified as above plus a calorimetrically certified heating value.
Figure 2. HYDROCARBON DEW POINT DIAGRAMS FOR VARIOUS METHANE BINARY MIXTURES, AS
PREDICTED BY SRK EQUATION-OF-STATE
----------------- Mole % -------------------
Components Sample 5 6 7 A (IGT) B (IGT) C (IGT)
5, 6, and 7: These methane-ethane blends were rejected because of their higher dew point temperatures as compared to
blend C.
A, B, and C: Gas compositions selected by IGT for the forthcoming new calorimeter calibration standards.
Certification of the three new calorimetry standards will follow the present protocol for the existing
program. In the case of the GC standards, concentrations of 10 components (methane through hexane plus
nitrogen and carbon dioxide) in the mixture will be certified to within a range of uncertainties based on
thorough statistical evaluation of analytical system performance.
Equipment Used. The paticular set of equipment that has been assembled and dedicated to the GC portion
of this program consists of the following principal components:
The chromatography data station transmits results to an IBM PC computer via RS 232 communications for
the purpose of data storage and evaluation.
The calorimetry certification program will continue to use the Cutler Hammer recording calorimeter that
has been the workhorse of the existing IGT program. This has been supplemented for the current program
expansion by the addition of a third calorimeter and construction of an automated, six-port gas manifold
sampling system to permit unattended measurements on batches of five cylinders.
GC Calibration Standard
Cylinder Material. A major area of effort of the program has been to verify that the choice of cylinder material
will not affect the stability of the calibration mixture. To test this, we filled duplicate sets of aluminum and
stainless steel cylinders with the calibration gas mixture from the carbon steel source cylinder. These five
cylinders have been analyzed on a monthly basis for the past six months. As expected, no significant
concentration changes in any of the 10 components are evident in any of the five cylinders at this point.
Precision of Certified Concentrations. The cylinder stability data, numbering some 150 separate analyses,
also form a basis set for statistical evaluation of instrument precision and accuracy. Our preliminary
evaluation of the collected data indicates that the componential analysis of the certified gas will produce an
overall precision well within the ASTM Method D-194581 repeatability requirements.
System Linearity. We are currently studying the overall GC system linearity for all the components over
a range of concentrations expected for common natural gases. A principal reason for this study is to
determine the validity of the certification procedure for gas compositions that may vary substantially from
that of the NBS primary standard.
Pressure Drawdown Tests. This series of experiments were designed to determine the effect of pressure
reduction on the stability of certified gas composition between a maximum filling pressure of 300 psig and
atmospheric pressure. Two sets of cylinders filled with a 10component gas blend, similar in composition to
our NBS primary standard, will be analyzed before and after each 50psig pressure reduction at different
gas withdrawal rates. The results of these tests will indicate the optimum rate of gas withdrawal as well as
the residual cylinder pressure for the GC calibration gas.
45
Calorific Standards
Three new NBS primary standards were obtained under the new program, designated as standards A, B, and
C. Composition and approximate heating values for these primary standards are listed in Table 2.
The primary purpose of the new standards was to measure the linearity of calorimeter response over its
entire range from 800 to 1200 Btu/SCF. Preliminary tests on three calorimeters show that there may be a
bias of +1.5 Btu at the midrange of the calorimeter. That means that when standard B (certified heating value
of 813.3 Btu/SCF) or standard C (certified heating value of 1186.1 Btu/SCF) are used to calibrate the
calorimeter and the other two standards are used as a test gas, only standard A (certified heating value of
996.6 Btu/SCF) reads high by 1.5 Btu/SCF. This study will continue for other points within the 8001200 Btu
range in order to develop an accurate calibration curve for future use.
THE ROLE OF CALIBRATION STANDARDS IN THE
ANALYSIS OF NATURAL GAS LIQUIDS
Stephen L.Brandt, B.S.
Chromatographic Standards Blending Engineer
Phillips Chemical Company
Phillips, Texas 79071
ABSTRACT
The natural gas liquids industry has been striving to measure the composition of liquid streams more
accurately. The chromatograph, with the use of calibration standards, has been found to be one of the most
accurate means of measuring the composition of natural gas liquids streams. This paper presents the
chromatographs need of calibration standards when analyzing natural gas liquids streams. The selection of
the proper calibration standard and the production of the standard is discussed. Also covered are cylinder
selection and sampling techniques which specifically include the three major cylinders used for liquid
samples. The final section of the paper deals with checking liquid calibration standards to insure
authenticity.
INTRODUCTION
Since the beginning of the natural gas liquids industry, there have been problems with the analysis of
natural gas liquid (NGL) streams. These streams are composed of a wide range of hydrocarbons with a low
percentage of non-hydrocarbon gases. The wide range of components make the analysis very difficult. The
early methods for analyzing NGL streams were not consistent or reliable; thus, the buying and selling of
NGL streams was very difficult. As the value of natural gas liquids increased due to their importance in the
gas industry, it became essential that a more accurate and reliable method be devised for the analysis of
natural gas liquids. The method that was devised was chromatography. Using the proper methodology,
chromatograph, calibration standards, and sampling techniques, the problem of analyzing natural gas liquid
streams were greatly reduced. This gave more consistent and reliable analytical results which reduced the
problems of buying or selling natural gas liquids.
47
Chromatographs
A chromatograph is a high efficiency distillation column. When a multiple component sample is injected
into a chromatograph it will separate each component. In the case of natural gas liquids the sample being
injected into the chromatograph will usually contain nitrogen, carbon dioxide, and hydrocarbons ranging
from methane through hexanes and heavier or any combination of the components. The chromatograph can
separate these components using the proper columns, but it cannot give a quantitative number. The
chromatograph is totally dependent upon a calibration standard to give a meaningful analysis to an
unknown. The GPA procedure 216575, Standard for Analysis of Natural Gas Liquid Mixtures by Gas
Chromatography and GPA procedure 217777, Tentative Method for the Analysis of Demethanized
Hydrocarbon Liquid Mixtures Containing Nitrogen and Carbon Dioxide by Gas Chromatography both
stress the importance of using calibration standards to get meaningful results by gas Chromatography. For a
proper analysis, an unknown would be injected into a chromatograph and run. The chromatograph would
then separate each component of the sample and draw a graph of its peaks known as a chromatogram (see
Figure 1).6 Each one of the peaks on the chromatogram represents a component of the unknown mixture. A
known calibration standard would then be run on the same chromatograph under the same conditions and a
chromatogram would be drawn of the calibration standard. The peaks of the unknown sample and the peaks
of the calibration standard would be compared, thus identifying and giving quantitative values to the
unknown peaks using one of two methods, Peak Area or Peak Height.7 The Peak Area method uses the
areas under each peak to calculate an area percent of each unknown component in the sample. The areas
under each of the peaks of the calibration standard are calculated and area percents are derived. The area
percents of the calibration standard are then correlated to the known mole percents of the calibration
standard and a response factor is derived. The response factor is then used to linearly correlate the unknown
samples area percents to mole percentages. The Peak Height method works in much the same way as the
Peak Area method, but uses the height of each peak to find the percentages of each component.
One problem with using the Peak Area or Peak Height methods is obtaining an accurate measurement of
the peaks area or height. This problem was solved with the use of an integrator; the integrator gives a more
accurate measurement and saves operator time. The results of the integrator can be fed into a computer and,
48 THE ROLE OF CALIBRATION STANDARDS IN THE ANALYSIS OF NATURAL GAS LIQUIDS
using proper response factors, the unknown sample can be analyzed accurately. Using one of the two
procedures and the proper calibration standard, a natural gas liquid can easily be analyzed.
49
A known blend prepared by weights of high purity components (99+ percent with known impurities)
to an accuracy within 0.05 percent (of the total blend) for each component is required for calibration
runs. The concentration of a component in the calibration blend should be not less than one-half of the
concentration of the corresponding components in the unknown; and in addition, corresponding
components in the calibration blend and in the unknown should not differ by more than five liquid
volume per cent (of the total mixture) if the peak height calculation method is used, nor by more than
20 liquid volume per cent (of the total mixture) if the peak area calculation method is used. In
applying the rules of this section the values for the hexanes and and heavier components may be
totaled and considered as a single component.8
If these rules for selecting a chromatographic standard are not followed, the calibration of the
chromatograph and the analysis of the unknown natural gas liquid will probably not be correct.
In the case of an ongoing analysis of an unknown stream with a reasonably consistent composition, a
calibration standard which duplicates the average of the stream composition should be used. This would
give the highest degree of accuracy to the analysis by eliminating any large, linear correlation between the
unknown stream and the calibration standard. Using a calibration standard which is tailored to a stream will
involve more time and expense, but will improve the analytical accuracy and justify the increased expense.
When selecting a calibration standard, the preceeding rules should be followed and a standard obtained
that duplicates the stream to be analyzed as much as possible.
1. Determine mol percent response factors for normal hydrocarbons using area measurements of
peaks recorded on chromatogram of reference standard run.15
The mole percent response factor is obtained by dividing the mole percent of the component in the reference
standard by the peak area or peak height.16
52 THE ROLE OF CALIBRATION STANDARDS IN THE ANALYSIS OF NATURAL GAS LIQUIDS
The molecular weights can be obtained from the GPSA Engineering Data Book, Section 16, Physical
Properties.
3. Using log/log paper plot the response factor on the vertical scale versus molecular weight on the
horizontal scale.
4. If all is in order the resultant plot will be essentially a straight line with a negative slope. For a
specific instrument, the angle of the plot should remain essentially constant. A change in the angle
usually indicates a change in blend composition. (Fig. 4).18
This procedure should be run on all new NGL calibration standards to ensure reliability and to give
confidence that the standard is of high quality.
CONCLUSION
The development and refinement of the chromatograph methods over the last 30 years has helped make
improvements in the analysis of natural gas liquids. The chromatographs have improved to a point that they
are run by computers and their accuracy is an industry standard. Calibration standards have improved in
accuracy by using techniques and equipment which allow standards to calibrate chromatographs in the parts
per million range; these standards would be worthless if cylinder technology had not progressed
significantly. With the use of piston displacement cylinders, natural gas liquids samples and calibration
standards can be injected into chromatographs with unsurpassed accuracy. As long as natural gas liquids are
bought and sold, there will always be a need to improve measurements of these streams.
53
REFERENCES
1. Sutton, C., Chromatography and the GPA, Seventh Chromatography School, December, 1977.
2. Ibid.
3. Ibid.
4. Ibid.
5. Ibid.
6. GPA Tentative Method for the Analysis of Demethanized Hydrocarbon Liquid Mixtures Containing Nitrogen
and Carbon Dioxide by Gas Chromatography, GPA Publication 217777, 1980, p.4.
7. GPA Standard for Analysis of Natural Gas Liquid Mixtures by Gas Chromatography, GPA Publication No.
216575, 1980.
8. GPA Standard for Analysis of Natural Gas Liquid Mixtures by Gas Ghromatography, GPA Publication No.
216575, 1980, p.3.
9. GPA Standard for Analysis of Natural Gas Liquid Mixtures by Gas Chromatography, GPA Publication No.
216575, 1980.
10. Ibid.
11. Ibid.
54 THE ROLE OF CALIBRATION STANDARDS IN THE ANALYSIS OF NATURAL GAS LIQUIDS
12. Ibid.
13. GPA Standard for Analysis of Natural Gas Liquid Mixtures by Gas Chromatography, GPA Publication No.
216575, 1980.
14. Ibid, p.4.
15. GPA Tentative Method for the Analysis of Demethanized Hydrocarbon Liquid Mixtures Containing Nitrogen
and Carbon Dioxide by Gas Chromatography, GPA Publication No. 217777, 1980, p.8.
16. Ibid.
17. Ibid.
18. Ibid.
COMMERCIALLY AVAILABLE CALIBRATION GASES
Dennis P.Norris
Technical Manager
Big Three Industries, Inc.
Mixed and Specialty Gases
P.O. Box 1026
La Porte, Texas 77571
ABSTRACT
Commercial calibration gases are presently prepared by several specialty gas producers. The quality and
technical support of these gases varies with the supplier. Todays highly advanced and sophisticated
instrumentation require carefully prepared calibration gases to optimize accuracy. These calibration gases
must be prepared and analyzed under a stringent quality assurance program. Failure to do this can result in
an integrity problem with the gas. Any error in the calibration gases can result in a high dollar loss from the
products being sold using their analysis. Big Three Industries has addressed this problem by introducing the
UniPhase calibration mixtures. These are single phase calibration mixtures with a technical validation
package that does not rely on instrument calibration. Another approach to this variant of calibration gases
from different suppliers is to reference these gases to a common source. This is now becoming available
from IGT and some of the major specialty gas suppliers, such as Big Three Industries. This common
reference is the National Bureau of Standards, which is world renown for their high degree of accuracy and
reliability.
INTRODUCTION
Todays analytical instrumentation has technically advanced into the space age. Much of the present
unmanned exploration of the outer reaches of our solar system utilize analyzers not unlike those found in a
commercial laboratory today. The accuracy and reliability of this instrumentation has improved many
orders of magnitude since its conception. With these improvements in the capability of measurement of
composition and physical properties, there is still a dependency on the reference pointthe calibration gas.
Not unlike the improvements in the instrumentation, the accuracy and the reliability of the calibration
gases have also improved. Today there are many commercial suppliers of calibration gas competing in the
56 COMMERCIALLY AVAILABLE CALIBRATION GASES
market place. This competition has benefited the analyst by forcing the commercial supplier to continually
improve the calibration gases they procure.
Homogeneity
The homogeneity of a calibration mixture simply means it is completely mixed. Once mixed, and if
maintained within the specified temperature and pressure limitations, a calibration mixture will remain
homogeneous. Only when a mixture is kept as a single phase, either all gas or liquid, will it be
homogeneous. The gas/liquid phase equilibrium will effect the homogeneity of a mixture that is not
maintained as a single phase. The plot in figure 1 is a typical example of a phase envelope of a multi-
component mixture. The upper curve of the envelope represents the pressure verses temperature conditions
for the bubble point of the mixture. The region above this curve represents the pressure verses temperature
conditions to maintain the mixture as a single phase liquid. The lower curve of the envelope represents the
pressure verses temperature conditions for the hydrocarbon dew point of the mixture. The region below this
curve represents the pressure verses temperature condition to maintain the mixture as a single phase gas.
The center region indicates the pressure and temperature conditions which would cause the mixture to exist
in both the liquid and gas phases. The conditions that would put the mixture into this center region must be
avoided if the mixture is expected to remain homogeneous.
Stability
The stability of a mixture must be confirmed through time related testing. This is usually not necessary
when dealing with hydrocarbon mixtures. Although there is some question to the reactivity between the
carbon steel or aluminum in the cylinder wall and the hydrocarbons contained in a calibration mixture, the
long term stability of typical natural gas product related mixtures has been proven. Only when corrosive
gases such as Carbon Dioxide or Hydrogen Sulfide are present is there need for additional concern. Even
these corrosive gases can be stable if the cylinder is completely dried and treated or pacified. Extra
analytical support is necessary when corrosive gases are included in the mixture. To verify the mixture
stability at least two analysis should bracket an incubation period of at least seven days. Any change in the
concentrations of the corrosive gas compositions greater than the analysis uncertainty of the analytical
measurement should be recognized as an indication of instability. The longer the incubation period between
analysis the more sensitive the testing will be to slow rate chemical reactions. A mixture must have this
confirmed stability to be used as a reliable calibration tool.
Accuracy
The results of the calibration must be accurate. The fidelity of these mixtures must be confirmed by
instrumental analysis. The problem with this technique is that instrumentation must be calibrated for the
57
Figure 1.
analysis. This means a calibration mixture must be obtained to analyze the newly prepared calibration
mixture. Until recently no common reference has been recognized for these calibration mixtures. This
created a situation which causes a variance from supplier to supplier in certified calibration mixtures. To
over come this problem, a statistical evaluation was developed by the Technical B committee of the Gas
Processors Association which is designated GPA 217784. The method plots the molar response of each
normal hydrocarbon from a gas chromatograph analysis with a thermal conductivity detector against that
components molecular weight on log/log paper. If all is in order the results will be essentially a straight line
with a negative slope. For a specific instrument, the angle of the plot should remain relatively constant. A
change in the angle usually indicates an error in the calibration mixture composition. An example of this
statistical plot is in figure 2. This type of evaluation allows the user to determine the fidelity of a calibration
mixture independent of intercomparison to another calibration mixture.
58 COMMERCIALLY AVAILABLE CALIBRATION GASES
Figure 2.
and corresponding data values in figures 8 and 9. Also shown is the linearity plot in figure 10 and the
hydrocarbon dew point curve for the calibration mixture in figure 11.
60 COMMERCIALLY AVAILABLE CALIBRATION GASES
Figure 3.
NBS TRACEABILITY OF CALIBRATION GASES
In September of 1983, a request was submitted by the Laboratory and Chemical Services Committee of the
American Gas Association, which outlined the need for a calibration gas for natural gas analysis by
chromatography which was certified by a recognized certifying agency. This request was undertaken by the
Gas Research Institute. The result is a program that will allow calibration mixture suppliers to prepare a gas
that will have a certified analysis traceable to a mixture certified by the National Bureau of Standards. This
program with the NBS will create a common source to which calibration mixtures can be traced. This
common source of traceability will create a reference point that can be used to resolve any dispute between
parties on questions of compositional accuracy.
The Gaseous Fuels committee (D-03) of the American Society of Testing Materials (ASTM) has
presently initiated work to establish a standard practice outlining the requirements necessary for a
calibration gas to be recognized as NBS traceable. With the availability of the NBS certified gases and
61
Figure 4.
guidelines established by ASTM for the requirements to meet NBS traceability, a calibration gas with a
certification traceable to a common source can be established.
CONCLUSION
The most important requirements of a calibration gas are that it is homogeneous, stable and accurate. The
most important job of the commercial gas supplier is to provide a calibration gas that meets these needs and
the technical support package to validate that claim. At Big Three Specialty Gases, we feel that the
UniPhase calibration mixtures meets these needs, and only with the technical UniPhasetm DATA
VALUES FOR LINEARITY PLOT (GPA 217784 (Only normal components plotted) CUSTOMER
Natural Gas Calibration Mixture No. Peak Mole. Wt. Amount Area Response x 10000 2 Methane 16.043 45.
101 3582650 0.12589 4 Ethane 30.070 4.659 507744 0.09175 5 Propane 44.097 2.500 325695 0.07677 7 n-
Butane 58.124 2.033 307670 0.06609 9 n-Pentane 72.151 1.084 183160 0.05920 10 n-Hexane 86.178 0.105
62 COMMERCIALLY AVAILABLE CALIBRATION GASES
Figure 5.
19084 0.05502 The line slope is 0.4960 The % Corrilation factor is 99.9776 GAS CHROMATOGRAPHIC
CONDITIONS Instrument Type: Varian 6000 TCD Carrier Gas: Helium Detector 0: TCD x 0.5 Detector:
TCD x 0.5 Injection Size: CSV 0.5 ml LSV 0.2 uL Operating Conditions: Isothermal at 115 C Column
Description: 30' x 1/8" DC-200/500 on Chrom PAW 80/100 mesh GAS CHROMATOGRAPHIC
RETENTION ORDER Time Component Area 2.00 Nitrogen 119879 2.14 Methane 3582650 2.52 Carbon
Dioxide 158657 2.80 Ethane 507744 3.78 Propane 325695 4.97 Isobutane 310334 5.83 n-Butane 307670 8.
50 Isopentane 177221 9.63 n-Pentane 183160 16.76 n-Hexane 19084 28.75 Heptanes Plus 20897 support
package that it provides can a user have all the information necessary to support their analysis.
The preparation of calibration gases is not unlike other present day technologies. There is a continual
effort to improve their quality and accuracy. A better understanding of the effects of these gases and their
limitations are constantly being improved. Methods to overcome these limitations are also being activily
developed. The ever increasing presence of the computer in the laboratory is also rapidly opening the doors
to a better understanding of the physical and chemical properties of gas mixtures. This understanding allows
the specialty gas producers to develop and supply a more detailed and accurate technical support package
with the calibration gases. This information arms the user with the tools to be more prepared to answer any
question about the gas analysis they report.
63
Figure 6.
64 COMMERCIALLY AVAILABLE CALIBRATION GASES
Figure 7a.
65
Figure 7b.
66 COMMERCIALLY AVAILABLE CALIBRATION GASES
Figure 8.
67
68 COMMERCIALLY AVAILABLE CALIBRATION GASES
Figure 10.
69
Figure 11.
COMPOSITE SAMPLING OF NATURAL GAS
Thomas F.Welker
Executive Vice-President, Marketing
Welker Engineering Company
Sugar Land, Texas 77487
ABSTRACT
The object of any sampling procedure is to obtain a representative sample of hydrocarbons from the system
under investigation. Any subsequent analysis of the sample, regardless of the test, is inaccurate unless a
representative sample is obtained. Due to the wide variation in flowing streams and the components in these
streams, the proper sampling techniques must be employed in order for the sample to be taken, transported,
stored, and finally analyzed by some type of test device. The first factor that must be covered is the person
chosen to physically take the spot sample, or install and maintain the sampling device. This person is the
beginning of a successful sampling program. The final outcome of the sample operation will be determined
by the efforts of this first link in an unbreakable chain of operations that must be performed without
variances which can and will affect the outcome of the results obtained. The philosophy of the persons
involved in the sample taking will need to be sound. Their techniques must conform to the requirements of
the technology and accuracy required in order to effectively take a representative sample. An inaccurate
sample could cost a company untold millions of dollars in lost revenue or contribute to the improper design
of plants, and in addition, cause incorrect plant or pipeline balances. The therm billing that is being used
throughout the industry requires that all functions of gas measurement, including sampling, be done with
considerable care and utilizing specific techniques.
Sampling
The sampling of natural gas has been discussed and studied for many years. Serious testing on the proper
sampling methods has been done in a number of locations in the recent past. From these tests, it has been
determined that the sampling procedures must be carefully prepared and followed. For a person to collect a
representative sample of natural gas, the procedures learned in spot sampling operations must be followed.
71
1. Sample point
2. Sample probe
3. Hook-up and manifold of sampler and cylinder
4. Sampler
5. Purging of sampler and cylinder
6. Sample cylinder, cleaning, purging, valving
7. Cylinder transport
8. Leaks on sampler and cylinders and related piping
9. Preventative maintenance of the sampler
To ensure the continuous or composite sampler will give accurate and repeatable results, the above points will
be covered briefly.
liquids moving along the walls and bottom of the pipeline take flight and act as a gas. When aerosols are
introduced into the sample container, condensation occurs. The sampler should be located in an area where
the gas is moving, A sample should never be taken from a shut in or dead end line. Areas to be avoided are
downstream of reduced port valves, control valves, check valves, obstructions and piping fittings. When
installing the sampler downstream of an orifice plate, the probe should be as far away from the orifice as
possible. Headers and blowdown stacks should be avoided as sample points. Samplers should never be
connected to meter manifolds. Install the probe in a straight run of pipe as far away as possible from bends,
tees, fittings or any type of obstruction in the line.
A sampler should not be installed without using a sample probe. A representative sample of any product
cannot be taken without the use of a sample probe.
Sample Probes
The use of probes in the sampling operation is imperative. Without the use of a probe in the line, an
accurate sample cannot be taken. A sample probe should be in the center one-third of the pipeline and
equipped with a full open ball or gate valve. The placement of the sample probe is important in all sampling
applications. Probes must be kept away from piping elbows, tees, manifolds, reduced port valves and orifice
plates.
Probe Construction
The probe should be constructed from a material that will not react with the product. 316 stainless steel is the
most practical material for probe construction. Probes are normally constructed in three different ways:
The stationary probe is installed as a permanent fixture in the piping system, A full open valve should be
attached to the outlet of the probe.
The tube extending into the flow path should be made strong enough to resist bending.
The manual insertion probe is used in locations of medium pressure where a permanent fixture cannot be
left in the pipe.
To insert the manual insertion probe, attach to a gate or ball valve and close the valve attached securely to
the end of the probe. Open the pipeline valve and very carefully push the tube into the flow line. Tighten the
fittings on the probe enough to hold the tubing in place and prevent leaks. Normally, the lower ferrule will
be nylon (or PTFE) and the upper ferrule will be stainless steel. Once the stainless steel ferrule is set, the
insertion depth of the probe is fixed. This type of probe must be handled carefully with special attention
given to locking the valve on the end of the probe and securing the probe into the insertion valve.
The installation of the sampler should always be as close as practical to the sample point. Never sample a
dead end line.
On the outlet of the sampler, the sample cylinder should be connected with a short length of small
diameter tubing. This is to be pumped into the cylinder, not some excessive length of tubing. Mount the
cylinder in some type of holder, not on the ground or deck.
The outlet tubing from the sampler to the cylinder must be carefully checked for leaks. Leaks allow the
sample to dissipate nonuniformly. Gas will leak from a cylinder light ends first giving inaccurate results.
Care should be taken not to put filters, drips, or regulators between the probe and the sampler. This
affects the gas and it is no longer representative of the pipeline product.
Sampler
The sampler is a mechanism that gives the operator an opportunity to have a composite sample in a cylinder.
It is an alternative to a spot sample and/or an onstream monitoring device. The sampler should take its
composite sample just as an operator would put a spot sample into his container. The sampler, however,
does this continuously over a specific period of time.
The sampler may be a simple timed mechanism actuating the sampler periodically. It may be interfaced with
measurement to cause the sample to be taken proportional to the flow electrically or pneumatically.
For stations or locations where the flow varies widely or the heating content swings up and down, the
sampler should be actuated proportional to the flow.
For stations where the load is constant, a timer may be used without affecting the gas collected.
For stations or wells that have flow, no flow operations, the sampler should be turned off with a flow
switch when the flow is off. Sampling should be stopped when there is no flow in every case. After a
number of years and many test locations, it is recommended that in locations where gas has a heating value
of 1025 BTU or above should be considered as prime locations for the use of a continuous sampler.
The sampler should be capable of pumping the sample into the sample container, regardless of ambient
conditions.
The sampler should be able to purge itself prior to pumping a new bite into the sample container.
The sampler should sample the gas at pipeline conditions.
should be checked periodically for ease of operation and must be checked for leaks through the seat,
bonnet, and threads. No leaks may be tolerated. Soft seat valves should be used on sample cylinders.
The sample cylinder should be cleaned after each use with solvent and then air dried. Sample cylinders must
be a proper working pressure to handle the source being sampled. Rising temperatures will increase the
pressure in the cylinder so this should be considered when choosing a sample container.
Cylinder Transport
When the sample period is over, the sample container should be disconnected from the sampler and
carefully checked for leaks. Plugs or caps should be installed on the valves. The sample information tag
should be filled out fully. The cylinder should then be put into a proper case for transport. D.O.T. rules
apply, even in your company trucks and autos. A cylinder should never be transported haphazardly.
Leaks
Leaks should not be tolerated in any portion of a sample system. Leaks will cause the sample to give
incorrect results.
1. Sampler head
2. 003 o-rings
3. Oring kit
4. Batteries for timer (if required)
Examples:
76 COMPOSITE SAMPLING OF NATURAL GAS
ABSTRACT
The energy content of natural gas is normally expressed in the United States as B.T.U. per cubic foot. This
definition, therefore dictates that a method of measuring B.T.U as well as volume must be considered if total
energy is to be measured. There are a number of methods and systems available to measure the B.T.U. of
natural gas. This paper will describe one of those methods based on a process gas chromatograph, the
Danalyzer, manufactured by Daniel Industries.
SYSTEM OVERVIEW
Gas chromatography is a method by which gas or vaporizable liquid mixtures are physically separated into
their individual components and quantified. There are three basic elements in any industrial gas
chromatograph:
The sample conditioning system provides a representative sample from the pipeline that is filtered and
pressure regulated. The sample conditioning system prepares the sample for the sample inject valve. The
sample conditioning system includes:
Sample probe for removing a representative sample from the pipeline. Usually the probe is a length of 1/
4 stainless steel tubing extending into the pipe approximately 1/3 of the pipe diameter. By sampling from
78 ENERGY MEASUREMENT WITH AN ON-LINE GC
Figure 1.
the center third of the pipe diameter, liquids and particulates creeping along the inner pipe wall are excluded
from the analysis system thereby increasing reliability.
Pressure regulator for insuring that the sample is presented to the sample inject valve at a relatively
constant pressure between 2 and 30 PSIG3%.
Guard filter for removing particulates 7 microns and greater in diameter from the gas.
Sample flow meter and needle valve for controlling the sample flow to the sample inject valve at
approximately 50 cc/minute.
Solenoid valves for stream switching of multiple analysis points and for introduction of calibration gas
during automatic calibration.
The analyzer is composed of five major elements.
The sample valve performs an extremely exacting function. It must take a precise volume of the sample
and inject it into the column each cycle. The sample volume and the injection rate must be identical from cycle
to cycle or the results will not be repeatable.
The oven temperature is also critical to sample injection repeatability. Even though the sample valve may
inject the same volume each cycle, if the temperature of the sample loop or valve varies, the density of the
gaseous sample will change. If the sample density changes then the number of sample molecules impinging
on the detector changes. This results in an unrepeatable system. The Danalyzer is designed so that the oven,
valves and detector are not effected by ambient temperatures of 0130F, The unit will still repeat to within
1/2 B.T.U. in a thousand over this temperature range.
The backflush and dual column valves are similar in design to the sample inject valve; however, their
function is slightly different. They are column switching valves. Column switching valves allow the sample
and/or carrier gas to flow forward through a column, bypass it or flow backwards. Column switching allows
the analyst opportunity to increase the speed of analysis and to perform more complete separation of the
components of natural gas.
The column system is the heart of the separating system. The Danalyzer column system is composed of
three basic columns. The first column is the backflush column and is used to separate the heavy
components, hexane+ from the rest of the components. The second column separates the intermediate
components, propane, iso-butane, normal butane, neo-pentane, iso-pentane, and normal pentane. The third
column is used to separate the light components, nitrogen, methane, carbon dioxide and ethane.
The columns are 1/16 stainless steel tubing packed with a media that selectively retards the flow of the
gas components. The selectivity of the column is dependent on the boiling point or partial pressure of the
individual pure components of natural gas. The lighter components will travel through the column system
faster than the heavier components. Each compound travels at a slightly different rate through the column
system and is eventually physically separated into a discrete band of the pure component. As the pure
component bands elute from the column system they enter the thermal conductivity detector for
quantification.
The micro thermal conductivity detector uses the property of thermal conductivity to detect and quantify
each component of natural gas. Thermal conductivity is a measure of a gaseous compounds ability to take
away heat from a hot body. In general, the lower the molecular weight the higher the thermal conductivity.
The micro thermal conductivity detector is a modified wheatstone bridge with two thermistors as two
opposite legs of the bridge. When the carrier gas, helium, passes over both the measuring and the referenced
side, the bridge is balanced and the output from the preamplifier is zero. When a pure component band
elutes across the detector, the component having less thermal conductivity than helium which is flowing
through the referenced side, takes away less heat from the measuring side unbalancing the bridge. The signal
resulting from the unbalanced bridge is directly proportional to concentration of the component eluting. The
signal is sent to the controller for further processing and for output to a recorder, printer or a host computer.
The carrier gas is the driving force in separating the components. It is the carrier gas that is introduced
into the sample valve and sweeps the sample into the column. The carrier gas is also the transporting
medium that pushes the components through the columns. The carrier gas also acts as a reference for the
micro thermal conductivity. No plant air is required to activate the oven valves, the carrier gas pressure
performs this function as well.
80 ENERGY MEASUREMENT WITH AN ON-LINE GC
Figure 2.
STEPS IN A TYPICAL B.T.U. ANALYSIS
Step 1: Prior to sample injection. Prior to injection, the sample purges the sample transport tubing and
sample conditioning system and vents out one side of the sample inject valve. Meanwhile, the
carrier gas flows through the rest of the separating system to the detector and out to vent. With
helium flowing across the detector, the system reads zero. The analysis is ready to begin. See
figure 2.
Step 2: Zero to 45 seconds. The sample valve switches to capture a precise volume of the sample and to
allow carrier gas to sweep the sample from the valve into the columns. The columns are
specially designed to hold and separate the components as follows.
Column 1 C6, C7, C8
Column 2 C3, C4, C5, C2, CO2
Column 3 Nitrogen, Cl
See figure 3.
Step 3: Forty-five to 90 seconds. The backflush valve switches to flip column 1, the backflush column,
so that the components are backed out of the column directly to the detector. C8, C7, and C6 are
lumped together to form one peak designated as C6+. Backflushing C6+ rather than allowing it
to travel through the entire system shortens the analysis time. By 90 seconds column 2 now
contains C4, C5, and C3 and column 3 contains C2, CO2, Cl and nitrogen. See figure 4.
Step 4: Ninety seconds to 350 seconds. The dual column valve switches to allow the components in
column 2 to bypass column 3 and go to the detector via the empty column 1. Meanwhile, the
light components in column 3 are trapped waiting their turn to elute. See figure 5.
Step 5: Three-hundred-fifty to 720 seconds. The dual column valve switches again to allow the carrier
gas to sweep the components in column 3 through column 1 and into the detector. The dual
column valve and column 3 allows for baseline separation between nitrogen and methane,
carbon dioxide and ethane. By separating each of the components completely, there is no error
due to perpendicular area allocation or any other indirect measurement technique. See figure 6.
CONTROLLER
The controller is the brains of the system. It is microprocessor based for flexible powerful data reduction
and report generation. The controller provides highly accurate timing for events like automatic calibration
81
Figure 3.
Figure 4.
Figure 5.
and valve switching, precision calculations, and report generation. It is also the interface for inputs from the
analyzer or operator to other devices through its analog outputs or by direct digital link.
A typical long analysis report is shown below. The operator can edit the report and create his own short
report by selecting only those parameters that are of particular interest. Twenty-four hour averages and
rolling averages of B.T.U. specific gravity, compressibility, wobbe or any other component concentration
are available. Up to 15 separate 24-hour averages can be printed. A typical analysis report is shown in
figure 7.
Each controller is environmentally tested for 10 days. The ambient temperature within the environmental
chamber is cycled 4 times a day from 40 to 140F while the electronic components are being exercised by a
quality control computer. Environmental testing of all components is essential to insure reliable field
operation. ANALYSIS REPORT (AGA CALCS) DATE: 07/30/85 ANALYSIS TIME: 780 STREAM
SEQUENCE: 1 TIME: 15s 17 CYCLE TIME: 900 STREAM#: 1 ANALYZER#: 5759 CYCLE START
TIME: 15:03 COMP NAME COMP CODE MOLE % GAL/MCF** B.T.U.* SP. GR.* C 6 + 108 0.029 0.
0128 1.52 0.0009 PROPANE 102 1.029 0.2832 25.98 0.0157 1BUTANE 103 0.313 0. 1023 10.20 0.0063
NBUTANE 104 0. 313 0.0986 10.23 0.0063 NEO C5 107 0. 103 0.0393 4. 10 0.0026 I PENT ANE 105 0.
099 0.0362 3.97 0.0025 N PENT ANE 106 0. 099 0.0357 3.96 0.0025 NITROGEN 114 2.485 0.0000 0.00
0.0240 METHANE 100 89.511 0.0000 905.94 0.4958 C 0 2 117 1.011 0. 0000 0.00 0.0154 ETHANE 101 5.
82 ENERGY MEASUREMENT WITH AN ON-LINE GC
Figure 6.
009 1.3389 88.81 0.0520 TOTALS 100.000 1.9470 1054.69 0.6239 * @ 14.730 PS I A DRY &
UNCORRECTED FOR COMPRESSIBILITY ** @ 14.730 & 60 DEG. F COMPRESSIBILITY FACTOR
(1/2) = 1.0024 DRY B.T.U. @ 14.730 PS I A & CORRECTED FOR COMPRESSIBILITY = 1057.2 SAT
B.T.U. @ 14.730 PS I A & CORRECTED FOR COMPRESSIBILITY = 1038.8 REAL SPECIFIC
GRAVITY = 0.6253 UNNORMALIZED TOTAL. MOLE % = 99.97 ACTIVE ALARMS NONE
SUMMARY
The gas chromatograph is an excellent tool for accurately determining a number of physical properties of
natural gas such as B.T.U., specific gravity and exact composition. The microprocessor and improved
design of the hardware aided by environmental chamber testing have made it possible to use gas
chromatographs in remote unattended locations. The Danalyzer is designed to provide the most stable,
reliable performance over the widest environmental conditions, 1/2 B.T.U in 1000 over the entire ambient
temperature range of 0130F. Each analyzer is thoroughly tested in an environmental chamber to assure
the reliable low maintenance operation that the gas industry requires.
83
Figure 7.
FIELD EXPERIENCE IN MEASURING ENERGY
DELIVERED WITH GASEOUS FUELS
William H.Clingman and Lyn Kennedy
Consultants, Precision Machine Products, Inc.
Kenneth R.Hall and James Holste
Chemical Engineering Faculty
Texas A&M University
ABSTRACT
A classic method of measuring energy delivered is to use an orifice meter run and a circular chart recorder
to obtain an integrated value for the flow. This flow measurement is combined with an average calorific
value to obtain energy delivered. This method can be biased when changes in the calorific value correlate
with changes in the flow. This classic method is next compared with two newer methods of measuring
energy delivered. The first method uses a flow computer which has as inputs the pressure, temperature, and
pressure differential from an orifice meter. This method also uses continuous measurements of relative
density and calorific value. The output from the flow computer is the instantaneous energy flow. The second
method uses a new energy flowmeter that is under development. It directly measures energy flow without
measuring either calorific value or volumetric flow.
INTRODUCTION
The general trend in the natural gas industry is to move toward therm billing of large customers. These large
customers are primarily power plants and industrial customers. Because the cost of fuel is rising and
because therm billing is applied to the larger users, a premium can be paid for more precise measurement of
the energy delivered. This paper covers our field experience with different methods of making this
measurement.
The experiments were carried out at a Lone Star Gas meter run outside of Bryan, Texas. The gas at this
site is odorized before distribution and the flow measurement is used to control the automatic addition of
odorant. Downstream about one mile from the site is a City of Bryan municipal power plant, which is a
major user of the gas. Remaining gas is distributed to the City of Bryan. About five miles upstream from the
site is a Champlin gas plant, which is the source of the gas. Gas flows at the site are of the order of 500,000
85
SCFH to 1,000,000 SCFH in an 8 inch line. The calorific value varies between 1000 and 1180 BTU/SCF
depending on the amount of ethane left in the residue gas by the Champlin gas plant.
Three methods for measuring energy delivered from the site are compared. The first method is the classic
method using an orifice flowmeter with circular charts and an average calorific value over the time period
being billed. The integrated volumetric flow over the time period corrected to standard conditions is
obtained from the circular chart. This integrated flow is multiplied by the average calorific value to obtain
energy delivered.
The second method uses a flow computer to calculate and record both the instantaneous and integrated
energy being delivered from the site. Continuous inputs to the flow computer are the pressure differential
across the orifice plate, the absolute temperature and pressure at the orifice, the relative density of the gas
from a gravitometer, and the calorific value from a calorimeter.
The third method uses a new device being developed under a contract with the Gas Research Institute. This
device is an energy flowmeter that measures the energy delivered directly without measuring either
integrated flow or calorific value. The device consists of two main components, a flow separator and a Flow
Titrator . The flow separator splits off a sample stream from the main flow. The flow separator operates so
that the ratio of the main flow to the sample flow is independent of the flow rate and the gas composition.
This ratio is called the split. The second component is a Flow-Titrator, which mixes a stoichiometric flow of
air with the fuel sample stream. This stoichiometric air flow multiplied by the split is proportional to the
energy being delivered in the main line.
In the following section of this paper, each of the three methods is described in more detail by giving the
specific parameters of the test equipment at Bryan. This section is then followed with a discussion of some
of the measurement errors associated with the classical method. These errors in principle can be eliminated
by using either a flow computer or the new energy flowmeter. The final section presents the experimental
results comparing these three methods of energy measurement at the Bryan test site.
TEST EQUIPMENT
In the classical method of energy measurement at the Bryan test site, the flow measurement was made by
Lone Star Gas with an orifice meter run. This run consisted of a 5 inch orifice in an 8 inch line. A standard
meter run was used with a flow straightener 10 feet upstream from the orifice. The differential pressure
measurement was taken from flange taps and recorded on a seven day circular chart. Also recorded on the
chart was the temperature and pressure of the gas in the line. All measurements of the calorific value and
relative density were made at the Champlin gas plant about five miles upstream from the orifice meter. No
other fuel was added to the line, however, between the two measuring points so the gas composition was the
same at both points. A Therm-Titrator was used for the calorific value measurement and a Ranerex
gravitometer for relative density. The two instruments were read hourly and these readings were averaged to
obtain an average calorific value and average relative density for the measurement period.
The circular chart was calculated by the Lone Star measurement department. This was done by tracing
the pressure and differential pressure curves with an integrater and using an average value of the gas
temperature. The average relative density was used in determining the meter factor for the orifice plate. The
integrated volumetric flow was multiplied by the average calorific value to obtain the delivered energy.
When energy delivered was measured by the flow computer the same orifice meter run was used. A
Rosemont differential pressure transducer, however, was used across the flange taps to obtain an electrical
signal for input to the flow computer. A pressure transducer was also inserted in the line at the orifice meter
run to provide a continuous electric input to the flow computer. The flow computer was manufactured by
86 FIELD EXPERIENCE IN MEASURING ENERGY DELIVERED WITH GASEOUS FUELS
Elliot Automation in Houston. Additional inputs to the computer were the calorific value and relative
density of the gas. These were measured continuously by a GB-2000 instrument from Precision
Measurement Incorporated (PMI). This instrument is a combination of the Therm-Titrator and a new PMI
instrument for measuring relative density. Although the flow computer was provided with a temperature
input, the temperature sensor had not yet been installed when the data presented in this paper were collected.
The temperature of the gas as recorded on a circular chart at the site varied from 83 to 87F. An average
temperature of 85F was programmed into the flow computer. From all of these continuous inputs, the
calculated instantaneous energy flow in the line was displayed on a strip chart recorder. The flow computer
used the relative density and NX-19 procedure to correct for supercompressibility.
The equipment for the third method of measurement, the energy flowmeter, consists of two main
components: a Flow Separator and a Flow-Titrator. The flow separator is illustrated in Figure 1. The flow
divides into two streams, a main flow and a sample flow. In each flow stream there is a constrictor which
produces a small pressure drop, In the main stream this constrictor consists of 720 parallel rectangular
channels, each with a length of one inch and dimension of 1/167/16. The hydraulic diameter of each
channel is 7/64. The channels are arranged in concentric rings about the center of the flow constrictor. This
constrictor is in the 8 line at Bryan and is located just downstream of an elbow and shut-off valve. A
sample line extends from the center of this flow constrictor to the outside of the spool piece which contains
it. Outside of the spool piece there is a capillary in the sample line which acts as a second flow constrictor.
Placed downstream from both constrictors are pressure ports which lead to a Rosemont differential pressure
gauge. The sample flow to the Flow-Titrator is regulated by a control value. The minicomputer of the Flow-
Titrator controls the sample flow so that the pressures are the same downstream from the flow constrictors.
The design insures that the upstream pressures are the same.
Under these conditions, the pressure drop across the flow constrictors is on the order of psi with a flow
in the 8 inch line on the order of 600,000 SCFH. The ratio of the main flow to the sample flow is called the
split. The split during most of the experiments at Bryan has been about 300,000. The split can be changed
by altering the capillary dimensions. It is a characteristic of the flow separator design that the split is
invariant with changes in the flow and gas composition.
The variation of the split with flow in laboratory tests is shown in Table 1. The separator tested was of
similar design to that at Bryan except that many fewer channels were used and the split was much less. The
channels had the same dimensions as at Bryan. The laboratory tests were made using air. The main gas flow
(air) was
measured with a calibrated Roots meter and the sample flow with a wet test meter. A tee was used to
separate the flow into a main stream and a sample stream. Both flow streams were vented to the atmosphere
after passing through their respective flowmeters which were downstream of the flow constrictors. Pressure
drops across the flowmeters were negligible compared to those across the flow constrictors. Thus the
arrangement assured equal upstream and downstream pressures between the main line and sample line. In
Table 1 the split appears as a function of gas flow Reynolds number in the channels. It is important to have
a constant split because then energy flow in the main line is always in the same ratio to energy flow in the
sample line. The latter energy flow is measured by the Flow-Titrator and then the main line energy flow can
be calculated from the split.
The second main component of the energy flowmeter is the Flow-Titrator. This is a modified Therm-
Titrator and its basic layout is shown in Figure 2. The fuel sample stream is mixed with air and burned. The
air flow is adjusted so that the air-fuel mixture being burned is essentially at the stoichiometric point. This
stoichiometric air flow is then measured and is proportional to the rate at which energy is being delivered in
the main line. A continuous output from the energy flowmeter is displayed on a strip chart recorder as the
percent of calibration reading for the instrument.
EXPERIMENTAL RESULTS
The first group of experimental results are shown in Table 2. These data compare the classic method with
the energy flowmeter. The energy flowmeter is under development with support by the Gas Research
Institute. Data obtained so far have been on a relative rather than an absolute basis. Equipment is still under
89
development for field calibration of the energy flowmeter and this is required for an absolute measurement.
Thus, in the tables the output of the energy flowmeter is given as the percent of calibration reading.
The error in any measuring instrument can be divided into three components: calibration bias, drift, and
random errors. In our experiments the emphasis has been on assessing drift and random errors for the three
measurement methods. Calibration error depends primarily on the quality of the standard that is being used.
Random errors occur in all measuring methods and drift may or may not occur. In our experiments these are
estimated by comparing two methods.
Assume that M1 and M2 are simultaneous measurements of the energy delivered by methods 1 and 2. Let
E be the true value of the energy delivered. In the methods that we have studied calibration involves a
multiplicative calibration constant. In that case,
where C1 and C2 are calibration errors, d1 and d2 are drift, and e1 and e2 are random errors. in successive
measurements with time C1 and C2 are constant, d1 and d2 would change monotonicaliy with time, and e1
and e2 would be random.
If there is drift in either instrument then either d1 or d2 or both will be significant and will either
continuously increase or decrease with time. Since the two instruments are independent, the drifts in each
will not be the same and the measurement ratio, (M2/M1) will also drift. In our experiments no evidence has
been found for a drift in the ratio (M2/M1) when comparing the energy flowmeter with either the flow
computer method or the classical method. Thus, it is concluded that none of the three methods being studied
have significant drift over the periods of measurement, which have been one to two weeks in duration.
90 FIELD EXPERIENCE IN MEASURING ENERGY DELIVERED WITH GASEOUS FUELS
The next step was estimating the magnitude of the random errors for the three methods from the measured
ratios (M2/M1) and (M3/M1) . In this notation the subscripts 1, 2, and 3 refer to the energy flowmeter, the
classic method, and the flow computer method respectively. Let s1, s2, and s3 equal the variances of the
measured values, M1 , M2, and M3. For example if there are N measurements or M1 then an estimate of s1 is
given by:
For a large number of data points the square root of the variance would be equal to the standard deviation for
the method.
The variance for the ratio (M2/M1) is given by (s1+ s2) when the variances are small. Thus (s1+s2) can be
estimated from the standard deviation for the data in Table 2, which is 3.5%. Likewise (s1+s3) can be estimated
from the standard deviation for the data in Table 3, which is 0.3%.
From this analysis it is possible to conclude from the Table 3 data that the precision of either the energy
flowmeter method or the flow computer method must be better than 0.3%. On the other hand it can be
concluded from the Table 2 data that the standard deviation for the classical method would be greater than 3.
4%.
CONCLUSIONS
Experimental work is continuing on these methods of energy measurement. From the initial data, however,
we can conclude that there are two alternatives to the classical method that can provide a significant
increase in precision. One method would use an orifice meter, flow computer, and continuous
measurements of calorific value and realtive density. The other is a new instrument under development
which measures energy flow directly. In addition to having a high precision these methods integrate an
instantaneous value of energy flow thereby avoiding errors caused by using an average calorific value.
ABSTRACT
Several process gas chromatographs (GCs) were tested to verify whether this instrument is an accurate
alternative to the calorimeter for measuring the heating value of natural gas. The test data presented in this
report is divided into three groups. Group 1 compares the rangeability and repeatability of several gas
chromatographs and a calorimeter to a laboratory GC, the reference standard. Group 2 compares the actual
operating data for three GCs and a calorimeter, which analyzed pipeline gas over a 104day test period.
Group 3 is a separate test, which compares operating data for one GC and a calorimeter for a for 93day
test period. The results showed that the process gas chromatograph is an accurate alternative to the
calorimeter. For Group 1, the GCs and the calorimeter had less than 1% error for gasses in the range of 875
to 1050 Btu/scf. For Group 2, the average heating value difference between the calorimeter and the three
GCs was 2.0 Btu/scf, while the average heating value difference among the gas chromatographs was 0.5
Btu/scf. For Group 3, the average heating value difference between the calorimeter and GC was 0.1 Btu/
scf.
INTRODUCTION
The average wellhead price of natural gas has increased twelve-fold in the past ten years. Because of this
increase, less expensive gas with heating values in the range from 700900 Btu/scf is being purchased. The
traditional heating value of distribution quality natural gas has been 1000 Btu/scf. Since gas is bought and
sold on an energy basis, the accuracy of the instruments which measure the heating value of the natural gas
is becoming increasingly important.
Two instruments used by the natural gas industry to measure the heating value of natural gas are: 1) the
combustion calorimeter and 2) the gas chromatograph (GC). These instruments measure the heating value
93
by two distinct methods. The combustion calorimeter directly measures the thermal energy generated from
the combustion of a known volume of gas. In contrast, the GC determines the heating value indirectly by
measuring the composition of the gas and calculating the heating value by using the heat of combustion of
each gas component.
The purpose of the test described in this report was to determine the ability of the GC to accurately
measure the heating value of natural gas and to determine whether the GC is an acceptable alternative to the
calorimeter. The data presented in this report compares three gas chromatographs with one another and also
with a calorimeter. The data is intended only as a comparison between direct and indirect Btu measurement
devices, and is not intended to recommend a particular manufacturers product. As such, all devices shall be
referred to as GC-A, GC-B, GC-C, GC-D and calorimeter.
BACKGROUND
Historically, the Cutler Hammer Calorimeter has been the standard in the gas industry for measuring the
heating value of natural gas. In fact, the Cutler Hammer Type AB Recording Calorimeter is the only
calorimeter accepted in the U.S. as a referee standard (ASTM Standard and Method D-1826). The
calorimeter determines the heating value by measuring the thermal energy released by the combustion of a
known volume of gas. The heating value measured by the calorimeter is usually recorded on a continuous
strip chart recorder.
Gas chromatographs have been used in the laboratory for many years. The old laboratory GC required an
operator to inject samples and to interpret the results. Recent advances in microprocessor technology have
allowed gas chromatographs to become automated process instruments designed for continuous and
automatic operation. The automated GC or process GC can operate on-line to a process, with no operator
required and analysis times of ten to fifteen minutes. Using the principle of selective adsorption, the GC
separates a natural gas sample into the various hydrocarbon constituents, measures the amount of each
component, and calculates the heating value, specific gravity and compressibility by using the physical
constants of each gas component (ASTM Standard and Method D-1945 and D-3588). The numerical results
of an analysis are usually printed, and include the mole percentage of each component, heating value,
specific gravity and compressibility.
Four considerations prompted the study of gas chromatographs as an alternate method of measuring
heating value and specific gravity.
1. The increasing cost of natural gas justifies an improvement in accuracy of the heating value and
specific gravity measurements.
2. The high cost of maintenance and unavailability of replacement parts required the replacement of old
calorimeters.
3. The cost of automated process GCs has recently become competitive with new calorimeters.
4. The use of microprocessors in process GCs allows the GCs to become an integral part of a gas
companys data acquisition system.
TESTING PROGRAM
A program was initiated to evaluate several gas chromatographs on the basis of accuracy, repeatability and
rangeability. These terms are defined as follows:
94 COMPARISON OF DATA FROM DIRECT AND INDIRECT BTU MEASUREMENT
1. Accuracy
Accuracy is defined as the degree of conformity of the measured value to the standard value.
2. Repeatability
Repeatability is defined as the ability of an instrument to repeat its readings over a given period of
time, given a constant input.
3. Rangeability
Rangeability is a measure of the practical operating limits. Chromatograph accuracy is dependent
upon calibration to a known reference gas composition. The amount which a sample gas composition
can deviate from the calibration gas while still maintaining accuracy is a measure of the
Chromatographs rangeability.
Test Groups
The data included in this report is from three different test groups. The data from the first group, Group 1, is
from laboratory testing of several gas chromatographs. The data from the second group, Group 2, is from
operating data gathered from three gas chromatographs and a calorimeter that are in field use. The data from
the third group, Group 3, is operating data from a separate comparison between a gas chromatograph and a
calorimeter that are in field use. All the GCs tested used a thermal conductivity detector to measure the gas
components. The main difference among the three groups is the presence of a reference standard in Group 1.
Group 1
Reference Standard. The control group for this phase of the testing was a laboratory GC. This device is the
most accurate and precise heating value measurement device in our system, and so was taken to be the
reference standard to which the process GCs and calorimeter are compared.
Calibration. The laboratory GC was calibrated with a calibration gas which was blended gravimetrically.
The amount of each component in the calibration gas was weighed with weights traceable to the National
Bureau of Standards (NBS). The gas composition was verified on a GC, and composition values stated in
the manufacturers certification were used in the calibration.
The process GCs were calibrated against the laboratory GC using another independently-supplied
calibration gas.
Groups 2 and 3
Reference Standard. The GCs and calorimeters operated under field conditions and did not have a reference
standard.
Calibration. The GCs and calorimeters were individually calibrated by a separate independently-supplied
calibration gas.
95
TEST PROCEDURE
Group 1
The testing procedures were developed to determine the accuracy, repeatability and rangeability of the
automated process gas chromatographs. These parameters were compared for several gas chromatographs
and also to a calorimeter.
Repeatability. For this test, two GCs were supplied by a cylinder of gas with a constant heating value.
The test was performed over a seven-day period, to allow for the effects of any instabilities or zero shifting
of the instruments to be measured. Since the cylinder contained a finite volume of gas, the normal sampling
time of ten to fifteen minutes would empty the cylinder before the end of seven days. Therefore, the GCs
were programmed to sample and analyze once an hour for a total of 170 analyses during the seven-day
period.
Rangeability. For this test, gas chromatographs A, B, and C, and a calorimeter were compared to the
laboratory GC at different heating value levels. The calorimeter was calibrated using the standard
calorimeter calibration gas from IGT.
Group 2
Group 2 data was gathered from instruments that were in actual field use. Specifically, the data from three
GCs and one calorimeter are analyzed. The results compare both chromatographs to calorimeters and
chromatographs to other chromatographs. This data lacks a reference device and, as such, reflects only the
relative difference between the respective instruments.
For this portion of the testing, three gas chromatographs and one calorimeter were compared against one
another. Each instrument was set up to sample and analyze gas from the same pipeline. Each GC was
calibrated with a separate calibration gas with an approximate heating value of 1023 Btu/scf.
Group 3
Group 3 is a separate comparison of operating data from a gas chromatograph and a calorimeter operated in
parallel for a 93-day period. This test was performed using a gas chromatograph (GC-D) and a calorimeter
that were set up in parallel. A single sample probe and sample line were used. Both instruments were
calibrated at the start of the test and were subsequently calibrated on a weekly basis. The gas chromatograph
was calibrated automatically while the calorimeter was calibrated manually.
The heating value of the calibration gas for the calorimeter and the GC were 1015 Btu/scf and 1027 Btu/
scf, respectively. The range of gas measured varied from 1044.2 to 1086.1 Btu/scf for the 93-day test period.
TESTS RESULTS
The test results are presented in two parts. The first part describes results from the laboratory testing (Group
1), and the second part shows data gathered from the instruments in field use (Groups 2 and 3).
96 COMPARISON OF DATA FROM DIRECT AND INDIRECT BTU MEASUREMENT
ResultsGuoup 1
Repeatability. The results shown in Figure 1 show the normal curve for GCs A and C. This is the
distribution of the 170 data points of the constant Btu gas for each of the two instruments. As can be seen,
the difference in the average heating value measured was 0.07 Btu/scf, or 0.007% of range, which is well
within the expected tolerances.
The standard deviation is a measure of the repeatability of a given measurement. As shown, GC-C has a
smaller standard deviation and is therefore more repeatable than GC-A. It should be noted that both devices
are within their manufacturers quoted tolerances of 1 Btu/scf.
Rangeability. As can be seen in Figure 2 , the accuracy of all the units is very good (0.2%) at heating
values above 950 Btu/scf. Below 950, the accuracy of GC-A and GC-B decreases rapidly with decreasing
heating value. In contrast, the accuracy of GC-C and the calorimeter remains fairly accurate even at the low
heating values.
This discrepancy at the low Btu levels is related to the devices rangeability or its ability to accurately
measure gas samples whose composition vary significantly from the calibration gas. The composition of the
lowest heating value gas differs significantly from the composition of the calibration gas. Specifically, the
low Btu gas has 23% nitrogen, while the calibration gas has 2.5%.
ResultsGroups 2 and 3
Group 2. Presented below are the results of the 104day test period:
This data is presented graphically in Figures 3 through 20 and represents the following pairs:
For each pairing of the data the following graphs are used:
97
As can be seen from Figures 14, 17 and 20, the agreement among the chromatographs is very good.
99
Figure 3. DIRECT VERSUS INDIRECT BTU MEASUREMENT (Calorimeter Compared to Gas Chromatograph A)
It should be noted that the Btu value for the calorimeter is read off a strip chart recorder and the GC
provides a printout of the actual heating value. Reading the heating value off the strip chart may induce some
errors, as it is subject to the operators interpretation.
CONCLUSIONS
The results of this series of tests demonstrate that the gas chromatograph can provide accurate and reliable
heating value measurement. From the field testing, Group 2, we can see that the the 104-day average
between the calorimeter and the gas chromatograph varies between 1.7 and 2.2 Btu/scf. This number is within
the combined accuracy tolerance as specified by the manufacturer.
In contrast, in Group 3, the 93-day test showed that the average heating value difference was 0.1 Btu/scf.
These results showed a much better correlation between the two devices.
Since the field data were gathered under actual operating conditions, there are many items that could not
be as carefully controlled as in a laboratory testing. Some of these items consist of: operating and
maintenance procedures, brief periods of equipment downtime and errors in calibration that could account
for the difference in heating value.
It is important to note, in Group 2, the very close agreement among the three GCs. All three GCs agreed
within 0.5 Btu/scf over the test period. Also, the number of data points that were within 1 Btu/scf ranged
100 COMPARISON OF DATA FROM DIRECT AND INDIRECT BTU MEASUREMENT
Figure 4. DIRECT VERSUS INDIRECT BTU MEASUREMENT (Daily Difference Calorimeter minus GC A)
from 94% to 99% for the three GCs. In contrast, comparing the calorimeters to the GCs, the number of data
points that agreed within 1 Btu/scf ranged from 28% to 40%.
In Group 3, comparing the calorimeter to GC-D, 71% of the data points were within 1 Btu/scf.
The most important point in all of this testing is the need to develop a high-confidence, primary standard
calibration gas for use with gas chromatographs, since an instruments accuracy is dependent upon the
accuracy of its calibration. This is particularly true for gas chromatographs that require calibration gases
with up to eleven components, with C6+ as low as .05% 2%.
The difference in the results from Group 2 and Group 3 indicate the need for a proper quality assurance
program to ensure accurate, reliable and repeatable heating value measurement.
Finally, the GC offers additional information that will help improve flow measurements by having live
data concerning specific gravity and CO2, N2 composition which is used in the AGA 3 calculations.
101
Figure 6. DIRECT VERSUS INDIRECT BTU MEASUREMENT (Calorimeter Compared to Gas Chromatograph B)
103
Figure 7. DIRECT VERSUS INDIRECT BTU MEASUREMENT (Daily Difference Calorimeter minus GC B)
104 COMPARISON OF DATA FROM DIRECT AND INDIRECT BTU MEASUREMENT
Figure 9. DIRECT VERSUS INDIRECT BTU MEASUREMENT (Calorimeter Compared to Gas Chromatograph C)
106 COMPARISON OF DATA FROM DIRECT AND INDIRECT BTU MEASUREMENT
Figure 10. DIRECT VERSUS INDIRECT BTU MEASUREMENT (Daily Difference Calorimeter minus GC C)
107
Figure 11. DIRECT VERSUS INDIRECT BTU MEASUREMENT (Calorimeter versus Chromatograph C)
108 COMPARISON OF DATA FROM DIRECT AND INDIRECT BTU MEASUREMENT
Figure 12. DIRECT VERSUS INDIRECT BTU MEASUREMENT (Chromatograph A Compared to Gas
Chromatograph B)
109
Figure 13. DIRECT VERSUS INDIRECT BTU MEASUREMENT (Daily Difference GC A minus GC B)
110 COMPARISON OF DATA FROM DIRECT AND INDIRECT BTU MEASUREMENT
Figure 14. DIRECT VERSUS INDIRECT BTU MEASUREMENT (Chromatograph A versus Chrorratograph B)
111
Figure 15. DIRECT VERSUS INDIRECT BTU MEASUREMENT (Chromatograph A Compared to Gas
Chromatograph C)
112 COMPARISON OF DATA FROM DIRECT AND INDIRECT BTU MEASUREMENT
Figure 16. DIRECT VERSUS INDIRECT BTU MEASUREMENT (Daily Difference GC A minus GC C)
113
Figure 17. DIRECT VERSUS INDIRECT BTU MEASUREMENT (Chromatograph A versus Chromatograph C)
114 COMPARISON OF DATA FROM DIRECT AND INDIRECT BTU MEASUREMENT
Figure 18. DIRECT VERSUS INDIRECT BTU MEASUREMENT (Chromatograph B Compared to Gas
Chromatograph C)
115
Figure 19. DIRECT VERSUS INDIRECT BTU MEASUREMENT (Daily Difference GC C minus GC B)
116 COMPARISON OF DATA FROM DIRECT AND INDIRECT BTU MEASUREMENT
Figure 20. DIRECT VERSUS INDIRECT BTU MEASUREMENT (Chromatograph B versus Chromatograph C)
117
Figure 21. DIRECT VERSUS INDIRECT BTU MEASUREMENT (Calorimeter Compared to Gas Chromatograph D)
118 COMPARISON OF DATA FROM DIRECT AND INDIRECT BTU MEASUREMENT
Figure 22. DIRECT VERSUS INDIRECT BTU MEASUREMENT (Calorimeter Compared to Gas Chromatograph D)
119
Figure 23. DIRECT VERSUS INDIRECT BTU MEASUREMENT (Calorimeter versus Chromatograph D)
ELECTRONIC FLOW MEASUREMENT FOR CUSTODY
TRANSFER
James M.Minich, P.E.
Design Engineer Specialist
NATURAL GAS PIPELINE COMPANY OF AMERICA
ABSTRACT
As the price of eras has risen substantially from the 20c/Mcf levels of days gone by, companies are
painstakingly measuring the flow in order to bill their customers accuratelyand charge them not only on
quantity, but also on the gas quality or heating content. In the last few years, pipeline firms have begun to
look at electronic flow measurement systems to replace the time-honored chart recorders. The electronic
process of collecting data inputs and performing the calculations in determining the flow of natural gas has
been engineered by Natural Gas Pipeline Company of America, a subsidiary of MIDCON Corp. The Control
Department has used minicomputer based control systems since the late I960s in the area of automation
and communications along its 12,750 miles of pipeline. As equipment is retired, it is replaced with new
state-of-the-art electronic equipment. Much of this ground work helped to develop an electronic flow
measurement system for natural gas. The flow calculation, based on the NX-19 study and AGA Report #3,
is accomplished with the use of software modules, inputs received from the gas chromatograph and operator
entered parameters and transducers. All of the hardware equipment was purchased from local vendors as
off-the-shelf items. Only a mininum of in-house design was required to interface field transducers, input/
output contacts and power. The bulk of the project consisted of the design, development and testing of
software programs. A microcomputer accepts all these inputs and executes a set of instructions that
calculate the flow of natural gas. Custody transfer refers to information obtained by electronic flow
measurement and used for billing purposes. Theres been a lot said about electronic flow measurement
replacing chart recorders and the potential savings in converting to electronic flow measurement. This paper
describes how this is done. NGPL began considering electronic flow measurement with the installation of
the Trailblazer pipeline. This accurate and repetitive calculation performed by the microcomputer allows the
program to execute control actions under variable input conditions. For example, a setpoint is changed in gas
121
FIGURE 1.
flow, or there is the need for an additional run, or the value of BTU has changed. The partners involved on
Trailblazer had met several times to discuss the type of information to be collected at the metering sites.
The entire system is developed around two areas: Hardware and software. A hardware block diagram is
shown in Figure 1. All software programs were developed and tested in-house.
Natural Gas Pipeline Company has developed an electronic flow measurement system for custody transfer.
The flow measuring system contains the following features:
1) Makes a flow calculation in accordance with NX-19 and AGA Report #3.
2) Receives BTU, Specific Gravity, N2 and C02 analysis data from a chromatograph. Having control over
the software allows the measurement department a choice in selecting a chromatograph. Currently the
microcomputer can interface with three different chroraatographs.
3) Has remote, local and standby control mode capability.
4) Produces a hard copy printout every hour, daily summary at 8:00 AM and on demand. Also all setpoint
changes and alarms, when set and cleared, are printed.
5) Accepts 32 analog inputs; 48 digital inputs and 48 digital outputs.
6) Contains complete hardware and software diagnostics for on-line debugging.
7) Allows operator changes of selected parameters(i.e. orifice size, run sizes, default value for BTU and
Specific gravity, override setpoints, etc) through the console unit.
122 ELECTRONIC FLOW MEASUREMENT FOR CUSTODY TRANSFER
8) Performs control routine actions such as flow control, runchanging, line break detection and back
pressure override.
9) Uses floating point double precision arithmetic for all computations.
10) Displays all active alarms to the operator through the console.
11) Converts and stores data into a data base using standard conventions-ASCII, Integer, and Floating point
formats. Attached to each value is a current status indicator. Data can be flagged as *old data, M
manually entered data, and b (blank)good data.
12) A calibration routine for transducers.
13) Projects flow over a 24 hour period.
14) Hourly log displays flow factors used in calculating the orifice flow factor constant for each run.
15) Hourly and Daily log record running accumulated flow totals per run.
16) Accepts a pressure override and flow control setpoints.
17) Capable of annubar or orifice plate measurement.
I would like to point out some advantages and disadvantages associated with the development of this system.
ADVANTAGES
a) Software changes can be made quickly and in direct response to the companys needs.
b) Modular construction allowed for quick and easy configuration of software modules.
c) The capability of troubleshooting software modules using an in-house debugging aid-IDR. This has
been the single most valuable asset in developing a working procrram.
d) Gives accurate and reliable flow measurements.
e) Software written by NGPL for earlier energy systems is compatible to new versions as they are
marketed.
f) Enables the real time collection of data for more accurate measurement over the conventional 24 hour
chart averaging.
g) hardcopy printouts are tailored to the station needs or a general format can be used.
h) the microcomputer can use various types of chromatographs
i) the use of two programming- languages, C and macro assembly. C is used in all flow calculations.
DISADVANTAGES
a) The process of debugging software programs has been a time consuming effort.
b) Considerable time was spent in training personnel on the new equipment and in documentating
procedures.
c) There were single transducers (static, temperature, and pressure) per run. Multiple transducers per run
would offer variable range coverages. For example, 050", 0100" and 0200". NGPL is planning to
experiment with dual range transducers inputs into the microprocessor at metering sites experiencing
wide fluctuations in flow rates.
d) Power interruptions as a result of electrical storms have been a bier problem.
The electronic flow measurement for custody transfer system consists of a microcomputer, gas
chromatgraph, H20 and H2S analyzer, a differential pressure, static and temperature transducers for each
123
FIGURE 2.
run, communications modem, power supplies and battery charger, printer, and console terminal. All of this
hardware, except for the printer, transducers, chromatograph and analyzers, is mounted to a free-standing
19" equipment rack. Terminal blocks are provided on this rack for analog and digital inputs (see photo).
Following is a description of topics considered in electronic flow measurement as approached by the
Engineering Control department of NGPL.
PHOTO
HARDWARE
1.0.1
THE MICROCOMPUTER
The microcomputer is the heart of the system. It is a 16-bit microprocessor with added features such as
memory management, FP-11 instruction set, double precision arithmetic, and four-level interrupt bus
structure. It and eight other boards collect and perform all the necessary calculations for an accurate flow
measurement. A typical backplane configuration depicting computer board placement is shown in Figure 2.
124 ELECTRONIC FLOW MEASUREMENT FOR CUSTODY TRANSFER
1.0.2
POWER
The main source of power is a battery charger that converts AC power to DC voltage levels required by the
microcomputer. Between the battery charger and backplane there are 3 DC regulated power supplies which
provide +5 and +12 volt for the backplane and +28 volts for tranducers. Battery backup is provided so that
the unit may operate for a number of days in the event, of a power loss. On the Trailblazer pipeline an
emergency power unit was installed. Its main function was to supply enough power to the chromatograph,
modem, and micro to continue giving analysis data during loner term power outages. An UPS
(uninterruptible power supply) should be a requirement in rural areas where power is not clean or reliable.
1.0.3
GAS CHROMATOGRAPH
Natural Gas Pipeline Company is evaluating a number of energy measurement systems that reports natural
gas data as each sample is analyzed, approximately every 13 minutes. The gas chromatocrraph reports Btu,
specific gravity, and gas composition by name and percent of content for each analysis and as a 24-hour
average at the end of each day. The chromatograph provides hardware diagnostics by number which allow a
user to check the machine before operation.
1.0.4
INPUTS/OUTPUTS
Data enters/leaves the computer by various methods. First, transducers are connected to analog inputs (32
maximum inputs) via a terminal block. Measurement transducers for differential pressure, static pressure
and gas temperature are installed for each run and interfaced to the microcomputer using an analog input. A
zero point is established and maintained as a reference point for analog signals. Second, digital input
contacts provide information about ambient temperature. AC power failure, write lock inhibit, and positional
information about valves. In most every case, they are nothing more than relay contacts. Third, digital
outputs are bit mask assignments that result in a control action. For example, the action may be pulsing a
solenoid that opens or closes a valve, or a time duration pulse that pulses a motor controlling a regulator.
All inputs and outputs have lightning protection and are coupled to the microcomputer through optical
isolators. Finally, serial communication data links are connected between the chromatograph, console, and
micro. The console furnishes the means by which an operator can manually alter a number of variables,
such as tap position, orifice plate sizes, run sizes, and flow setpoint. It also displays individual data items by
entering the correct request code and performing the proper read or write operation. Normally these
functions are performed locally. See APPENDIX E.
1.0.5
PRINTERS AND HAND-HELD (CONSOLE)TERMINAL
Data values can be retrieved from the computer in five different ways. First, individual data items can be
requested and displayed on the console unit. Second, multiple data items can be looked at by referring to the
hourly and daily reports printed automatically. Third, data can be polled by a partner through an
asynchronous serial communication link in an agreed format. Fourth, remote commands and data requests
can be entered through a synchronous serial communication link over a microwave system. Gas control in
125
Lombard or Houston can poll remote sites and are capable of sending a flow setpoint, changing orifice and
pipe diameters, and requesting individual/all data items. For example: alarms, flow rate, H20 content, BTU,
C02, etc.. Finally, service personnel can attach a CRT to view 120 memory locations.
SOFTWARE
The software is the brains of the system. It is responsible for collecting transducer and chromatograph data,
sensing and sending contact closures, remote and local communications and the time base and event driven
execution of control routines. Routines most commonly used are flow control, runchanging, backpressure
override and linebreak. The memory itself is limited to 32k-16 bit words and the last 4k is designated as the
I/O page. Memory is divided into two parts: UVPROM and Random Access Memory. In the event of a power
loss the program is non-volatile. Using a Prolog Prom Programmer the program is burnt on 4k 8 UV
PROMS. The number of proms used is dependent on the length of the program. Approximate size of the
current program is 16k. The ram portion of memory is a static CMOS read/write memory with battery
backup. This 12k of ram is used as a scratch pad area for data values, calculations, flags, buffers, pointers,
counters, etc. If a power loss is experienced data is retained. Ram memory can be cleared by the operator.
The software is modular in construction. That is any module can be removed or inserted with no adverse
effect on the overall operation of the program. Testing of software modules requires a three-step process.
First, a module is individually tested until all bugs are ironed out. Second, it is then added to the overall
system where it undergoes further debugging. Finally, the program is installed and field tested. It may
require additional changes because no bench test can give every possible condition. However, the program
is very accurate and logical in carrying out its many sequences of operation. The EXECUTIVE routine
controls the sequence in which the individual programs run. It does this by executing a series of subroutine
calls first on a non-timed basis followed by those on a timed basis. The EXECUTIVE also has the duty of
monitoring remote communications. In the event of a communication loss, the communication program is
re-initialized. On a startup there are several modules that define hardware addresses to memory locations
and various bit mask assignments, assign addresses and processor status to all the interrupt vectors, reset the
system hardware and initialize all the system software and hardware. A software block diagram is shown in
Figure 3.
2.0.1
SYSTEM STARTUP
The configuration information required by the program is entered by the local operator during a prompt and
answer session. The number and type of questions can vary from one location to another. Normally, the
following information is requested: stream selection, plate and run size for all runs, static tap location
(upstream or downstream), default values and upper and lower limits for BTU and specific gravity, and a
flow and back pressure override setpoints. In entering the last prompt value, the microcomputer begins
executing the software modules. The operator still may exercise control or change data through the console
terminal. For example, he can change the control mode to either local or remote, plate or orifice sizes, tap
location, time and date, and force the program into a calibration. He may also view any value, or alarms
using the console terminal. To view the current flow value the operator would key in a number code and the
terminal would display the current value. The read operation can be performed at any time. However,
changes made to the program, as in a write operation, are controlled by a key interlock switch preventing
accidential or unauthorized entries. A fail-safe feature in case of a computer malfunction is the
126 ELECTRONIC FLOW MEASUREMENT FOR CUSTODY TRANSFER
FIGURE 3.
incorporation of a watchdog hardware timer. If the timer is not strobbed within a given period of time, the
DC power is cut off to the equipment control circuits.
2.0.2
GAS CHROMATOGRAPH
The microcomputer polls the chromatograph for gas heating value, specific gravity, gas composition for
each analysis and 24-hour averages, the asynchronous digital link permits the program to remotely
interrogate and gather data from the chromatograph. The link is activated by modules ECOM1 and ESTAT.
Basically these modules request a message, determine its status and process the data received for the current
127
sample analysis. If the 24-hour averages are available, they too are collected and stored in the data base
common. Once stored in the database, other software modules convert the data into applicable data formats
and store them in the database.
Of the three chromatographs used one is capable of transmitting 9 messages. Of these only five are
requested. Type 4 message is polled continuously since it contains current data analysis, 24-hour average
analysis and alarm information. To ensure that the micro did indeed receive the messages sent by the
chromatograph, a cyclic redundancy checksum (CRC) is performed(bit error detection). The chromatograph
calculates a CRC and stores it as the final two byteslow byte transmitted first. The micro using the same
polynominal [P(x)=x16+x12+x5+1] compares its result with the CRC sent in the received message buffer.
Only after the message has successfully been identified does it get processed. As an example the following
data messages are requested from a chromatograph:
The dicrital link between the microcomputer and eras chromatographs operate asynchronously, 1200 baud,
and in full duplex mode.
2.0.3
HARD COPY PRINTOUTS
The software can support three types of printers. Each printer is capable of displayina identical information
if necessary. However, the format is different for each case. The first printer has 132 characters/line the
others 80 and 32. (See APPENDIX C for examples.) Printouts are supplied locally and to partners wishing
to tie into an asynchronous port with their own equipment. The printouts need not be identical. That is, the
information printed for our billing purposes may not be identical to others, or they just may like to see
additional data points. Whatever the case may be, various files are built with the desired information and
outputted using various FORMAT modules. These modules, respond to basic directive commands and are
directed through a serial communication link to external eguipment.
Chromatograph values on the hourly log and averaae values on the daily log are flagged with their
current status. Indicators are of the following type: *old data; Mmanually entered data; and b(blank)
for current good data. An example would be, BTU * 1044.0 BTU/cf or BTU M 1044.0 BTU/cf.
2.0.4
FLOW CALCULATIONS
The microcomputer, together with a gas chromatocrraph and transducer inputs, computes a gas flow rate
based on AGA report #3 and PAR research project NX-19 equations. A flow calculation is performed every
10 seconds and memory locations are updated based on these latest calculations. At the various metering
sites, each run is handled as an independent flow calculation and the sum of these calculations provides a
total flow measurement for the station. Also, in addition to a gas flow rate value, a therm flow rate value is
128 ELECTRONIC FLOW MEASUREMENT FOR CUSTODY TRANSFER
also calculated by multiplying the BTU by the total flow. The final value is converted to dekatherms. In the
event of a power loss, battery backup ram is provided for memory retention of system components.
Orifice flow rate calculation and supercompressibility factor are calculated using floating-point double
precision data type. This greatlv improves the accuracy of arithmetic operations allowing direct operation
on double precision 64-bit words. All flow calculations are performed using C programming language.
Currently the program is a hybrid using C and macro assembly language. Orifice flow factors are
calculated and printed on the hourly report per run allowing an operator a means of rechecking the total flow
computation.
There are three modules that perform the necessary calculations required for flow measurement: FLWRAT,
AGAFPV, and ORFLC. The first is the orifice flow rate calculation, C'. (See APPENDIX A for detailed
information.) For this calculation the operator can select tap location, UPSTREAM or DOWNSTREAM for
flange taps. Note: pipe taps were not considered since they are not used. The second is the
supercompressibility factor, Fpv. Finally, the gas flow rate is calculated in MMCFD and MMBTUD.
The accuracy of the microcomputer flow rate calculation was compared to a FLOW FINDER modular
program inserted into the hack of a TI59 calculator. This together with an overlay and instruction manual
provides all that is necessary to verify a flow calculation. This module is available from the SOLTAR
Corporation located in Spring, Texas. Ive listed what appears to be the differences between their method of
calculation and the one we use in Appendix B.
2.0.5
CONTROL ROUTINES
Not only is the microcomputer a data acquisition system, but also a control system. It collects and transmits
data and performs the necessary control actions based on current flow calculations. Modules are
periodically run by the EXEC to determine if control is necessary. The control programs implemented are
flow control, runchanging, backpressure override, and linebreak detection.
Flow control controls a regulator that responds to a flow setpoint received from a remote location or
entered locally through the console. Results of the current flow are compared to the setpoint and differences
between the two will increase or decrease the position of the valve.
Runchanging monitors the differential pressure on run number one for 90 inches of water. If reached, the
next available run is opened only after the current flow is reduced by 60%. This prevents the orifice plates
from receiving a large flow of gas and possibly damaging the plates. If there are no further runs to open and
the DP is at a maximum, runchanging will control the controller so that the DP will not exceed 90 inches.
Likewise, if all available runs are open and DP drops below 10 the furthest available run from run #1 is closed.
When closing a run there is no need to reduce the flow.
Linebreak detection will monitor rate of flow and pressure differences on a timed basis. Currently this
module is under development.
Back pressure override looks at down stream pressure. If it exceeds a predetermined level, the condition
is flagged and the flow controller will control the flow of gas through the regulator so that downstream
pressure is below the pressure setpoint.
129
2.0.6
CALIBRATION
Since tranducers are calibrated on a periodic basis, a module called CALIBC was designed to allow
calibration of the transducers using the console unit and a series of front panel switches. A mode switch
allows the operator to view transducer inputs (analog signals) in three formats: Engineering unite, counts,
and voltages.
2.0.7
DIAGNOSTICS
To ensure that the hardware and software are operational there are available to the operator hardware and
software diagnostics. There are three levels of maintenance. For the first level there are hardware
diagnostics available for the chromatograph and microcomputer. The measurement operator or
communication technician can perform these tests before he starts the system UP. The chromatograph
software has 8 self checks built into it which flag contradictions in its logic. These errors are a result of
some system failure. Also the chromatograph provides a diagnostic package designed for rapid on-site
verification. The microcomputer provides diagnostic programs that test the processor, the memory and the
users console.
The second level of operator maintenance is through a software module called DGNSTC. The diagnostic
module operates in coniunction with front panel LEDs and toggle switches. DGNSTC interprets the 16 panel
switches as a memory address and outputs the contents of that memory address on the LEDs. Peripheral
device addresses (considered memory addresses by the hardware) can be viewed as well. If a byte address is
selected, it is displayed in the low byte of the LET) word. Switches requesting a display of a non-existent
memory location cause all ones to appear on the LED lights.
The third and final level of maintenance, not made available to the operator, is an IDR or interactive
display routine. IDR is a diagnostic utility which enables the user to view and change the contents of
memory locations in a program being debugged. This module when assembled with the program displays on
a CRT, 3 full pages or 120 memorv locations showing critical buffers, pointers, counters, etc.
(APPENDIX D illustrates such a page of information that might be displayed in troubleshooting a control
routine called RUNCHG.) This scanning technique was developed in-house to assist in the debugging of
software modules before they are introduced into the field. This has been the most valuable tool in the
development of software modules.
2.0.8
COMMUNICATIONS and PARTNER HANDOFF
The communication processor routine, COMM, has the duty of handling data requests and command
messages from the Master station via microwave communication circuits. Natural Gas Pipeline Company
has developed its own protocol to which a cyclic redundancy checksum (CRC) is added for error checking.
The generating polynominal used for CRC or error bit detection is X16+X15+X2+1. Partners wishing to
retrieve information from the processor database have available an asynchronous RS232 port. They need
only connect a cable between this port and their equipment. NGPL has designed a ASCII format
transmission for partner handoff. This communication format that NGPL uses for data exchanges is 1200
baud, asynchronous with 1 start bit and 2 stop bits, all bytes 8 bit ASCII (except CRC), no parity,
transmitted as often as requested(normally between 1 and 10 minutes), and appended with a CRC.
130 ELECTRONIC FLOW MEASUREMENT FOR CUSTODY TRANSFER
2.0.9
MISCELLANEOUS ROUTINES
The previously mentioned routines are by far the most important, but there are other programs necessary to
complete the successful operation of the flow measuring system. I would like to mention a few of these: A
software library that stores a collection of routines useable by any module within the software structure;
input and output modules designed to handle contact and control signals; internal averaging and conversion
routines for data handling; a real-time line clock for the date and time; a millisecond timer; a module that
projects flow over a 24-hour period; and a routine that calculates a total down time of a run. Each station
has these and other programs necessary for total and accuracte flow measurement.
2.0.10
CURRENTLY UNDER DEVELOPMENT
Currently NGPL is looking at upgrading the measurement system to take advantage in the state-of-the-art.
For example NGPL is evaluating a unit that has a 20Mb hard disk drive, 2Mb floppy, self contained power
supply and 48 backplane all within a single package. Not only is the hardware under going a change but
also the software. The software is a hybrid of macro assembly and C. Our target is to convert the entire
program into C and install a OS and C compiler on the hard disk eliminating the need for UVPROM and
use the floppy to record statistical and necessary data to be used by gas accounting in its billing of
customers. The floppy is seen as possibly storing up to 30 days worth of data.
3.0
CONCLUSIONS
The Control Department of Natural Gas Pipeline Company has developed an electronic flow measurement
system that accurately computes gas flow data and yet allows flexibility in the overall performance and
operation of the system. Features can be added to the system simply by burnincr a new set of UVPROM in
exchange for the old ones (hardware changes may be necessary). The advantages of an electronic flow
measurement system experienced thus far are: Information is available immediatelylocally and remotely
a much more accurate flow measurement compared to chart recorders, and the flexibility of addina and/or
modifyincr software programs quickly.
Currently NGPL has 14 flow measurement systems in service. Four of them are on the TRAILBLAZER
system. A data acquisition, control and flow calculation program is operating successfully at Natural Meter
in Beatrice, Nebraska.
APPENDIX A
The basic flow equations follow the AGA Report #3 and NX-19 equations for supercompressibility. Please
refer to the publications for further explanation.
APPENDIX B
131
APPENDIX C
APPENDIX D
APPENDIX E
FUNCTION DEFINITIONS
ABSTRACT
This paper deals with real time energy measurement from the industrial gas users point of view. It illustrates
how real time energy measurement by the user allows him to optimize his combustion process utilizing
automatic combustion control and high speed measurement devices for feed forward and feedback systems.
Applications
A. Mixing of Gases. Mixing of gases is done for several reasons. Pipelines may inject rich gas to meet
minimum BTUs as specified in the sales contract.
Gas utilities inject various mixtures and amounts of butane air, or propane air, for peak shaving. These
mixtures can be anywhere from 1010 BTU to 1550 BTU depending on the percentage of peak shaving. LNG
is popularly used for peak shaving. Some utilities supply LNG for base load input. There may still be in
operation some SNG plants used for peaking shaving or base load.
In the refinery and petrochemical area, a typical blending application involves blending of by-product or
waste gases with a natural gas supply to optimize use of internally produced fuel gas. For the steel industry,
a very significant user of fuel gas, optimizing involves mixing of blast furnace gas so that it will burn. Steel
makers blend a variety of mixtures of blast furnace gas and coke oven gas, and natural gas plus air, for
maintaining total flexibility within a plant production to optimize energy delivery and/or consumption.
To mix fuel gases on line, a sample feedback control loop is often used, such as that shown in Figure 1. This
depicts a ratio controlled flow sytem reset by the heat value measurement to produce a gas with a constant
136 REAL TIME ENERGY MEASUREMENT
Figure 1.
Figure 2.
heat quality. There are many other variations of the calorimeter based blending operation which includes
either wild flow blending or feed forward control. In all cases, the ultimate objective is to obtain a fuel gas
of constant CV or Wobbe Index based on the specific requirements and application of the blended gas.
B. Feed Forward Combustion Control. Largo consumers of fuel gas are discovering that the gas flow
control systems they have employed for years car no longer deliver a controlled heat flow to their burners.
The typical industrial combustion process consists of pressure or flow control loop and a feedback loop
see Figure 2to reset the pressure or flow of gas to the burners based on load.
These conventional control loops were based on the requirement that both the specific gravity and
calorific value (BTU/SCF) of the fuel gas remain constant. We have illustrated that this is not true for most
industries and localities. As a rule, the composition of these gases varies even within relatively short periods
resulting in fluctuations in calorific value and relative density.
Controlling the pressure and flow of a fuel gas alone cannot deliver a constant heat flow if the gas
composition varies. The control problems presented by gas composition variations can be overcome by
adding a hi-speed calorimeter to monitor heat value and by using a conventional flow orifice to measure
flow to an existing burner control system. These two measurements, heat value and flow rate, in
combination with the conventional control and feedback loop based on loan, provide the basis for effective,
continuous feed forward control of the burning process.
The high-speed calorimeter referred to burns and measures the heat value of a continuous sample of the
gas in terms of Wobbe Index.
137
Gas flow is determined by measuring differential pressure (P) across an orifice in the gas line. P is corrected
for pressure and temperature to more correctly represent gas flow.
The feed forward control loop built around the high speed calorimeter (Fig. 3) compensates for changing
gas characteristics in advance of combustion. The combination of feed forward control using Wobbe Index
plus a process feedback loop assures the user of correct process heat and makes possible significant
reductions in excess air. Those save fuel and do not sacrifice safety or product quality.
With the advent of microprocessor on line high speed calorimeters can be monitored to assure reliable
calibration and control for reproducible control of the desired set point. SMARTCAL (tm) is such a
dedicated microprocessor to interface with calorimeters for auto-calibration and various diagnostic and
alarm functions to assure on-line reliability.
Conclusion:
The ability to measure heating value accurately and quickly and apply this for immediate correction in a
feed forward system is current state of the art. Systems like this that maintain optimum combustion and
process efficiency are certainly the key to Real Time Energy Measurement and energy management.
138 REAL TIME ENERGY MEASUREMENT
Figure 3.
ENERGY MEASUREMENT ACCURACY
R.N.Curry, Retired
Texas Gas Resources Corporation
ABSTRACT
The theme of this panel What Needs to be Done to Achieve Energy Measurement Accuracy opens a host
of doors! Those areas that come most immediately to mind are cybernetics, gas ehromatography, computer
systems hardware and software, theory and thermodynamics, mathematical technique, and undoubtedly
numerous other technological and scientific facets associated with metrology! Most of these areas have been
thoroughly wrung out by the engineering and scientific communities and there is an abundance of
published data concerning same. In essence, I believe that energy measurement accuracy is generally
available to us now within acceptable engineering tolerancesat least for hydrocarbon fuel gasesand
what we must now do to achieve greater accuracy is establish a precise method for gathering the data and
deriving the units of energy in a manner universally consistent between all concernedbuyer, seller,
transporter, etc.
Consequently, what I believe must be done is in the areas of standardization and education. This can
probably be best accomplished by the publication of a single document such as has been done for gas
measurementANSI 2530.
Any number of standards have been published by generally acceptable but different professional
organizations but there are conflicts between these standards and while such conflicts may be of minor
concern to those technically familiar, they are of great consternation of others associated with the industry,
more specifically, lawyers, accountants, and non-technical executives. Some examples are:
And there are others. This makes the case for a universal standardat least for the North American
continent. A professional task group should be established to review and evaluate all currently available
standards and compile items into one document, hopefully, with the sanction of all organizations. That will
not be easyjust ask Mr. Hoglund!
The educational effort would be directed toward the use of such a standard and to familiarize the public
as well as hydrocarbon fuel industry employees with energy measurement. Neither will that be easy. We
have people currently in the industry that think the difference between gross or total and net heating value
for gas is the same thing as the difference between wet and dry. And, yes, some of them are technical
employees. You know the lawyers and accountants say we dont even know what to call it
MMBtu, Dekatherm, Joule, or what?! And, heating value is non-dimensional, consequently, one cannot tell
the engineer to design a pipeline or a prime mover for X MMBtu per day. He must know mass or volume.
Recently, after a rather lengthy explanation of an energy measurement contract clause with a client and
when asked if he fully understood, he replied, yes, but how many MCF is that?
So, it becomes apparent, that energy measurement accuracy will be greatly enhanced through
standardization and education in addition tot he conventional improvements needed.
Natural Gas Energy Measurement II
Presented
April 30-May 2,1986
Chicago, Illinois
CALCULATION OF THE HEATING VALUE OF NATURAL
GAS FROM THE PHYSICOCHEMICAL PROPERTIES OF
THE PURE COMPONENTS
Kenneth N.Marsh, Ph.D.
Director, Thermodynamics Research Center
Texas A and M University
College Station, Texas 77843
ABSTRACT
In the gas industry, the value of natural gases are based on their gross heating values (gross calorific
values). Other properties that are important for calculating the amount of gas on a volumetric scale are the
relative density (specific gravity) and the compressibility factor. The gross heating value is difficult to
measure accurately for a flowing stream whereas the analysis of the composition of the stream by gas
chromatography can be done accurately by well established techniques. Thus it is possible to replace a direct
calorimetric measurement by a composition determination and a knowledge of the gross heating values of
the various components of the gas. We have recently made new recommendations for determining the
heating values and the specific gravity of selected components of natural gas based on a re-evaluation of the
available experimental data. The method for calculating the gross heating value from these recommended
values will be outlined. This calculation method is applicable to all common types of gaseous fuels
including dry natural gas, reformed gas, propaneair, carbureted water gas, and retort coal gas provided
suitable methods of analysis for all the components of the gas are available.
INTRODUCTION
The gross heating value of a gas is the maximum amount of energy that can be obtained from burning a unit
of the gas when liquid water is formed as a product. When using gases as heating agents, the relative merits
of gases from different sources and with different compositions can be compared on the basis of their
heating values. The gross heating value of a fuel is also used to determine the price of gas in custody transfer,
and it is required to calculate the efficiencies of energy conversion devices such as gas turbines.
143
The specific gravity (relative density) of the gas is required for calculating flow through pipes and
orifices and to establish the relationship between the amounts of gas measured volumetrically to the
corresponding mass or molar amounts. The relative density can be determined from a knowledge of the
molar volumes of the component gases as a function of temperature and pressure and selected binary
mixture properties.
Since the gross heating value of a gas is difficult to measure accurately in a stream, the alternative
method of calculating the heating value from a compositional analysis and the heating values of the
individual components is preferred. For custody transfer purposes, particularly across national boundaries,
it is important to establish a set of internationally accepted values for the gross heating values and the molar
volumes of the major components of natural gas (1). Natural gas consists of methane with small amounts of
other hydrocarbons, principally in the range of 2 to 6 carbon atoms, carbon dioxide, nitrogen, argon, water,
and hydrogen sulfide. When burned in oxygen or air, the products of combustion are carbon dioxide (and if
hydrogen sulfide is present, sulfur dioxide) and water. The heating values of the components must be known
over the range of reference temperatures used in each of the different countries exchanging natural gas. This
temperature range is from 0 to 25C (32 to 77F).
The gross heating value of a gas, Q, is the total energy generated in an ideal combustion reaction at a
standard temperature and pressure in which all the water that is formed appears as liquid (2,3). The ideal
gaseous state is chosen for the reactants and products so that the numerical value of Q is independent of the
actual state of the reactants and products. For example, the heat released by one pound of methane burned at
1 atmosphere pressure at 60F will be slightly different from that released under the same conditions if the
gas was assumed ideal. The gross heating value of a gas is thus an ideal gas property and it is the negative
of the standard enthalpy of combustion, . Calculation of the exact heat produced by the combustion of
mixtures containing many components would require a very large amount of auxiliary data on the
multicoraponent mixtures and a very complex program. Further, it is more important that all parties agree to
the same method for calculating the gross heating value, rather than having an exact value, which would
differ slightly from the ideal gas value.
(3)
144 CALCULATION OF THE HEATING VALUE OF NATURAL GAS FROM THE PHYSICOCHEMICAL PROPERTIES OF
THE PURE COMPONENTS
Conversion to the gross enthalpy of combustion requires subtraction of the ideal enthalpy of vaporization
for water, . This value is slightly larger in magnitude than the enthalpy of
vaporization:
(4)
Values of standard enthalpies of combustion for the individual components are normally tabulated in
kilojoules per mole and are for the formation of liquid water as a product. Because the heating value of a
natural gas is an ideal gas property, the gross enthalpy of combustion for a mixture is the sum of the
standard enthalpy of combustion times the mole fraction of each of the components,
(5)
where HC (T,gross,mixture) is the gross enthalpy of combustion for the mixture, xi is the mole fraction and
c is the number of components. The gross heating value of the mixture on a molar basis, is
(6)
and this value can be converted to the gross heating value on a mass basis by division by the molar mass
of the mixture M given by:
(7)
Hence
(8)
The gross heating value on a volume basis results from multiplying by the ideal gas density:
(9)
For a dry gas, these calculations are straightforward provided the enthalpy of combustion data are available.
However, the calculation for a wet or saturated gas requires further interpretation.
where xw is the mole fraction of water in the gas, and is the vapor pressure of pure water at temperature
T. For purposes of this calculation, it is permissible to assume the liquid phase to be pure water ( )
and then
(15)
Additional assumptions required are either a) the gas and liquid phases are ideal and the liquid
is incompressible or b) all non-idealities for the system cancel identically. Raoults law is probably
satisfactory when dealing with natural gas systems at conditions close to ambient (between 0 and 25C at
approximately 1 bar).
In the above calculation, water contributes to the gross heating value from the reaction
(16)
which equals the ideal enthalpy of vaporization. Thus, because water vapor enters with the gas, it is possible
to interpret the gross heating value as including the enthalpy difference caused by condensing this
spectator water vapor to liquid water. After much discussion, GPA Standard 217286 has chosen to adopt
this interpretation. While it may be argued that this is not rigorous, no calculation involving wet or saturated
gas can be rigorous. In fact, the method of calculation which is the least ambiguous and least susceptible of
errors is that on a dry, net, mass basis. The most ambiguous and most prone to errors is the calculation
based on a wet (or saturated), gross, volume basis, and this is the value required for custody transfer. Under
the selected interpretation, the gross heating value for wet or saturated gas per unit volume is
(17)
and
(18)
COST OF ENERGY
When valuing natural gas, the energy delivered to the customer is the pertinent quantity. The cost is:
(18)
where p is the price per quantity of energy delivered. This value can be on an ideal energy basis or an actual
energy basis. As noted previously, the ideal gas value is much easier to uniformly calculate and to
ultimately defend. is the energy released as heat during a time period t.
On the ideal basis, the heating value produces from
(19)
where is the molar flowrate. Conversion to a mass flowrate gives:
(20)
where is the mass flowrate. On a volumetric basis, it becomes
(21)
where is the ideal gas flowrate. Note that each of these expressions is valid, but usually the gas industry
wants to deal with real gas flowrates:
(22)
where is the real gas flowrate. Summarizing these various expressions
(23)
The details of calculating the compressibility factor are given in reference 4.
This latter expression clarifies common misconceptions. It is simpler and more accurate to calculate using
molar, mass or ideal gas flowrates. An objection might be that flowmeters, such as orifices, produce not
. While this is true, it is also true that with exactly the same information required to develop it is possible
to develop , , or . When using or , it is not even necessary to deal with the base pressure because
and are independent of pressure while is not.
Another misconception is that division of by Z produces the real heating value. This is not true.
Division of by Z produces which, when multiplied by , provides . is possible to correct the heating
value from an ideal property to a real property, but it is a tedious and not very accurate calculation involving
equations of state and their derivatives. In addition, the difference between real and ideal heating value is
usually a small value at base conditions.
CONCLUSIONS
The heating value is an ideal gas property which, when used with composition, can rigorously provide a
cost expression for natural gas. Rigorously, this should be a calculation based upon dry gas, net value and
per mass. Unfortunately, many contracts specify the calculation basis as water saturated gas, gross values
and per volume. In this latter case, it is an open question as to how to handle the water carried by the gas if
it is wet or saturated. In this paper, the calculation includes this spectator water which can add about 0.1%
to the heating value.
Values can be on an ideal or real basis, but the ideal basis is much simpler and probably more easily
defendable. In addition, molar, mass, ideal gas or real gas flowrates are all acceptable although molar or
mass are preferable followed by ideal gas, and lastly real gas. Finally, division of by Z does not provide
147
the real heating value, but only allows the use of a real gas flowrate rather than an ideal gas flowrate in the
cost equation.
REFERENCES CITED
1. Hall, K.R., Yarborough, L, Lindsay, R., Kilmer, J., Fling, W., Calculation of Gross Heating Value for a
Saturated Gas from Compositional Analysis, International Congress of Gas QualitySpecification and
Measurement of Physical and Chemical Propeties of Natural Gas, Gronigen, The Netherlands (1986), April.
2. Gas Producers Association, Calculation of Gross Heating Value, Relative Density and Compressibility Factor for
Natural Gas Mixtures from Compositional Analysis, GPA Standard 217286 (1986).
3. American Society for Testing and Materials, Calculating Calorific Value and Specific Gravity (Relative
Density) of Gaseous Fuels, D 358881 (1981).
4. Gas Processors Association, Table of Physical Constants of Paraffin Hydrocarbons and Other Components of
Natural Gas, GPA Standard 214585, (1985).
GAS FLOW MEASUREMENT: CALIBRATION
FACILITIES AND FLUID METERING TRACEABILITY AT
THE NATIONAL BUREAU OF STANDARDS
G.E.Mattingly, Ph.D.
Senior Scientist for Fluid Measurements
Fluid Flow Group
Chemical Process Metrology Division
Center for Chemical Engineering
National Bureau of Standards
Gaithersburg, MD 20899
U.S.A.
ABSTRACT
As the value of scarce fluid resources increases in todays domestic and international market places and
process industries so does the need for improved fluid measurement and for improved traceability to
primary standards. Both buyers and sellers of fluid products are increasingly concerned about accurate
custody transfer. Designers and operators of industrial processes are increasingly concerned about the
precision of their fluid measurement to optimize the performance of their continuous production
technologies. To satisfy these expressed needs for improved fluid measurements and traceability in the wide
range of fluids and conditions required, is a considerable task. The calibration facilities which flow gas and
which are currently in use at the National Bureau of Standards (NBS) are described. The performance
characteristics of these facilities are given together with corresponding levels of uncertainties. The concept
of measurement traceability is described. The application of this concept to fluid measurement is presented
together with strategies and techniques for establishing Measurement Assurance ProgramsMAPs for
flow measurements. The critical ingredients for establishing assured flow measurements are also described
as well as an efficient and effective way to process the data that results from such an activity. It is concluded
that improving the state-of-the-art in fluid measurement is an evolutionary progression. The fundamental
bases for fluid measurements are the primary standards established in the reputable laboratories in the
pertinent country. These laboratories, together with the countrys national laboratory, can and should provide
for realistic, quantified, and continuing traceability of the nations important fluid measurements. In this
way, market place equity can be properly and satisfactorily established and appropriate measurement and
control can be installed and maintained for optimal productivity in the chemical process industries.
149
INTRODUCTION
Standards. Flowrate standards could be significantly simplified if the fundamental bases of these
measurements were as simple as those for mass, length, etc. These systems of measurement are based upon
discrete standards* or artifacts. For example, the platinum kilogram known as K-20 is the ultimate
artifact to provide the fundamental basis for mass measurement in the U.S. and the platinum meter bar (or
its modern-day wavelength equivalent) is the ultimate artifact to provide the fundamental basis for length
measurement.
Identity Standards. These mass and length artifacts can be considered identity standards because under
the appropriate conditions of use they define the basic quantity in their respective measurement systems.
However, for flow rate measurements of fluidsi.e., liquids or gases, there does not exist an identity standard
such as a gallon per minute, a liter per second, or a kilogram per hour. To supply the fundamental basis
upon which to establish a flow measurement system, a derived standard is needed.
Derived Standards for Flow. For gas flow measurementsas needed to form the basis of a national
reference systemcalibration facilities spanning a range of fluid and flow conditions are maintained by NBS
for use by industry and others. These facilities consist usually of:
Calibration systems are generally categorized according to the type of flow determination scheme used.
Several of these schemes will be described below.
Flow Determination Systems. The heart of the gas flowmeter calibration facility is the flow determination
system. This generally uses a timed collection of the gas which flows through the meter being calibrated.
The amount of the gas collected is determined by gravi metric or volumetric techniques. This collected gas
is converted to mass flowrate using the collection time; the volumetric flowrate through the meter can be
determined using the pertinent thermodynamic properties measured at the meter. This system can be made
to perform at a high level of performance to determine the bulk flow rate of gas.
Levels of Performance. Measurement systems can be characterized via their precision and accuracy.
These are briefly defined as follows:*
*The term standard is used to refer to paper standards which are documents; it is also used to refer to reference
facilities and equipment; it is also used to refer to the specific materials needed to transfer measurement quality from or
between facilities. These specific materials are referred to in what follows as artifacts.
150 GAS FLOW MEASUREMENT: CALIBRATION FACILITIES AND FLUID METERING TRACEABILITY AT THE
NATIONAL BUREAU OF STANDARDS
These characteristics apply to measurements made by flowmeters and to measurements made using
calibration facilities.
Facility Performance. For gas flow calibration facilities, the precision can be evaluated from the
appropriate error budget and from the precision of the component measurements that constitute the system.
Difficulty is encountered when facility accuracy is to be quantified because the true value of the gas
flowrate is not easily obtained. To estimate possible systematic offsets from true value, approximations
generally very conservative, are frequently used. Alternatively, and more preferably, a realistic and highly
defensible traceability scheme either is available or can be generated and is appropriately used to document
the systematic offset of a calibration facility.
Traceability. Traceability is defined many ways by many people, see Appendix 1. Conventional
calibration procedures can establish traceability of types 1 and/or 3.
Conventional Calibration Procedures. With conventional calibration programs, a testing laboratory or a
meter manufacturer or a meter user might own and routinely use a master meter technique to assess the flowrate
measurement performance of the laboratory. To do this, the master meter might be sent yearly to NBS for a
calibration in the appropriate NBS flow facility. This done, the meter would be returned to the laboratory
with a report on its performance in the NBS facility. The meter would be placed into the respective facility
in the laboratory and then calibrated. The relative performance of these calibrations would hopefully
compare very favorably and thereby document the closeness of agreement between the laboratorys facility
and NBS. This procedurewhile widely used at the present timecan leave a considerable number of
factors affecting measurement completely unassessed. Traceability of type 4 (see Appendix 1) might be
established for a flowmeter calibration laboratory in the following manner. If calibrated weights (for
example from a state office of weights and measures) were used to check a scale system and if a timing
standard were used to check the labs timing system, then traceabilitytype 4 could be asserted for the
labs weigh-time system. However, the overall ability of the lab to calibrate a flowmeter can be quite
incomplete. For such reasons, it is widely believed that type 2 traceability is preferred. This type 2
traceability can be established and maintained via flow measurement assurance programsi.e., flow MAPs.
Flow MAPs. In the case of flow MAPs, a procedure different from the conventional calibration one is
used, see [14].* This involves NBS (or an initiating laboratory) sending a very reliable and well
characterized artifact package (i.e., tandem meter arrangements consisting of two meters in series) to the
laboratory in question with the request for a calibration of the device(s) according to tightly specified and
prearranged conditions. The resultswhich would contain the effects of all the labs routine calibration
proceduresits facilities, its operating conditions, its personnel, and its techniques for calculating final results
from raw dataare then sent to NBS. These can be objectively (and informedly) compared to NBS results
or, more preferably, to similar results from a number of other comparable labs which have performed the
same tests in a round-robin set of these calibrations. In these comparisons, NBS results are also
incorporated as one of the participants. The results show quantitatively, the agreement (or disagreement)
among the participants results. Algorithms have been developed to handle these results, see [58]. Fig. 1
shows a comparison of conventional calibration procedures and those that can occur with MAPs. The
comparison shows that the crucial advantages of the MAP program are that: (1)all aspects of the
(1)
where, in compatible units M is the substantial time derivative of the mass in the control volume, p is the
mass density, p/t represents the partial derivative of fluid density p with respect to time, is vector
153
velocity of the fluid and is the control surface element of area with a direction taken outward and normal
to surface A. The first term on the right hand side of (1) represents an integration covering total volume V to
find the rate of accumulation of mass, m/t, in volume V if density p is not constant. The second term on
the right represents net mass rate of flow through the control volume surfaces. Application of Eq. (1) to each
of the control volumes a, b and c of Fig. 2 gives three equations, which when added together gives mass
flowrate as
(2)
where subscripts 1 and 4 represent surfaces illustrated in Fig. 2, subscript n represents the normal
component of velocity at the surface, and subscripts, a, b, and c represent the respective control volumes.
Calibration Facilities at NBS. Calibration facilities are available at NBS for offering calibration service
for meters that flow gas,* see [13]. These are performed using air or other gases. Capabilities are shown in
the chart shown in Fig. 3. Dashed lines in 3(a) indicate planned extensions of rate. Estimated systematic
errors for the calibrations as plotted in 3(a) will be discussed in more detail in other parts of this paper.
Typical reference flowmeters calibrated may add from 0.05 to 0.3% uncertainty to the systematic error
shown as a result of imprecise meter readout and possible meter and flow instabilities under field conditions.
Gas Flow: Static Procedure. A P, V, T, t (pressure, volume, temperature and time) tank is used as the
NBS primary standard for high rate gas flow, see Fig. 4. Filtered and dried air (dew point of about 50 C
at 8.5 atmospheres absolute pressure) at rates up to 85 m3/min (3000 scfm) are the original design
conditions for this system. The tank contains approximately 28 m3 (1000 ft3) and is used for measurement
of air flow rate via the temporal increase in gas density in the constant volume tank. The measurements are
called static as both volume and density changes can be measured at presumably stationary conditions.
Dynamics are involved only in opening and closing motions of the diversion valves which are timed to give
the collection interval. Collection volume capacity is derived from weighed gaseous nitrogen fillings of the
tank in conjunction with density as determined from temperature and pressure measurements. Results from
separate fillings of the tank with gas indicate that a volume uncertainty of 0.01% can be achieved. Gas
temperature in the tank is measured with 10 thermistors that are calibrated against a platinum resistance
thermometer which was calibrated by NBS Temperature Section. Two calibrated thermistors are located on
each of 5 horizontal concentric circles distributed vertically so that the average temperature of the gas is
accurately measured. A fan is installed to stir the air in the tank to remove stratification effects. Thermistor
elevations are shown in Fig. 4. These temperature sensors, in conjunction with others for measurement of
tank metal temperature, and a pressure gage provide information to derive collected gas density and an
estimate of its uncertainty. Although the environment of this large tank may not be well controlled, its small
surface to volume ratio and use of the circulation fan permit the volume to be derived with an acceptable
uncertainty. Using this facility, NBS sonic nozzles are proved and then used as transfer standards to
calibrate meters flowing air.
Conservation of mass principles, as applied to this measurement system for a finite measurement interval
t, can be written,
(3)
*Special Test facilities exist at NBS in Boulder, CO. These use cryogenic fluids. A description of these facilities can
be found in [14]. In addition, low flow rate helium permeation leaks testing capabilities will be available at NBS in
1986.
154 GAS FLOW MEASUREMENT: CALIBRATION FACILITIES AND FLUID METERING TRACEABILITY AT THE
NATIONAL BUREAU OF STANDARDS
FIGURE 3(b). TABULATED SUMMARY OF NBS GAS FLOW CALIBRATION FACILITY CHARACTERISTICS.
mass are comparable (or both insignificant) total uncertainty can be in the range 0.04 to 0.10% without
consideration of an uncertainty in t.
Gas Flow: Dynamic Procedure. Filtered dried air (dew point about 40 C at 35 atmospheres absolute
pressure) is measured at rates up to 1.4 m3/min (50 cfm) with piston and with bell-type provers
arrangements such as those sketched in Figs. 5 and 6. Motion of the mercury-sealed piston in its vertical
glass tube is timed (after an initial acceleration period) with a timer actuated by two photo sensors when
their light beams are interrupted by the piston, see Fig. 5. The light beams that traverse the glass tube are
placed a known, vertical distance apart, and each is constricted to about 0.01 cm. in the direction of piston
travel. Vertical motion of the bell in its annular bath of sealing liquid is timed by similar switches actuated
successively by the vertical motion of the bell, see Fig. 6. Interval diameter measurements are used
(via calibrated calipers or via strapping techniques with an NBS calibrated tape) to derive volume per unit
of distance traveled for both provers, additional measurements being required to account for displacement
motion of the sealing liquid in the bell-type prover, see [12].
Careful attention to numerous details is necessary to avoid measurement difficulties. These arise from
small rates of flow and small collected volumes, from considerations involving dynamics of the
measurement process, and from difficulty in making meaningful gas temperature measurements in small gas
156 GAS FLOW MEASUREMENT: CALIBRATION FACILITIES AND FLUID METERING TRACEABILITY AT THE
NATIONAL BUREAU OF STANDARDS
(4)
where, in compatible units: piVc represents the mass of gas collected in the prover during its stroke of
volume Vc as based on density pi at initiation of collection, with system gas density pe existing at
termination of the calibration period. Volumes Va and Vb represent not only meter and connecting pipe
volumes, respectively, but also gas volume in such things as instrument lines, and any volume collected in
157
Temperature 0.03
Timer, clock 0.005
Timer, switching 0.06
These combine to form a possible overall systematic error in the range 0.075 to 0.165%. More reliable and
credible bounds to the systematic error can be established via MAP programs. Some of the observed
imprecision of rates as evaluated by repeated measurements with these provers can be regarded as
connected with the other three terms on the right side of equation (4) and with sensitivity and repeatability of
the flowmeter under test. Two terms in (4), (pepi) and (Va+Vb) are connected with dynamics of prover
motion as affected by its design, by the procedure used, by dynamic response of the instruments, etc.
Environment also affects precision through changes of ambient pressure and temperature, the latter causing
heat transfer. Combining the above uncertainties, estimated standard deviation for a flowrate determination
is generally between 0.1 to 0.2% when testing better meters.
159
Once these necessary quantifications are completed, it remains to assess the bias, or systematic errors in
laboratory measurement capabilities. This can be done via estimating but it is better achieved via
traceability established via flow MAPSi.e., round robin testing. This topic is described and discussed
below.
Flow Measurement Traceability. To establish traceability of the type 2 variety (see Appendix 1) a test
program must be devised so that:
(1) high confidence can be placed in the artifact packagethe meters assembled and the specifics of the
procedures, check-points, responses to anticipated anomalies, etc.,
(2) the data base produced is adequate to the task of clearly evaluating the significant components of the
systems that participate, and
(3) the algorithm for processing the data and producing the results is an unbiased and clear procedure that
is adequate to this task.
Artifact confidence is established via calibration testing over an extended period of time for the kind of
conditions that will be used in the round robin. This testing should occur in the initiating laboratory and it
should establish a credible background data base for the units being tested. Specifically, high competence
can be attained by calibrating two (2) meters in series according to tightly specified conditions. This type of
configuration is shown in Fig. 7. Pre-testing of these configurations gives expected values for the respective
meter factors as well as for the relative performance of the metersi.e., the ratio of their outputs.
*These values should be considered as reasonable estimates. Currently, efforts are underway at NBS to re-evaluate the
performance of all the calibration facilities that are used to offer calibration services, see [10, 13].
160 GAS FLOW MEASUREMENT: CALIBRATION FACILITIES AND FLUID METERING TRACEABILITY AT THE
NATIONAL BUREAU OF STANDARDS
Adequacy of the data base is established by specifying the number of repeat calibrations done for each
flowrate and meter configuration. These results should produce sufficient data so that statistical significance
can be generated to exhibit the quality of measurement performance(1) how this varies for successive
calibrations done for the same conditions over short periods of timei.e., repeatability (see Appendix 1),
and (2) how this varies from day to day for conditions that may vary slightlyi.e., reproducibility (see
Appendix 1). It is recommended here that the data base be generated efficiently and for the expressed
purpose of testing laboratory performance. To do this, a minimum number of flowrates are used and
sufficient tests at each are done. An alternative approach might be to use numerous flowrates and minimal
replications at each. However, this alternative approach tends to place emphasis on meter characteristics
as opposed to test laboratory characteristics.
The algorithm for data processing should be well established. This attribute is achieved when it is (has
been) used for a number of MAPs for other measurement systemsi.e., the procedures produced by W.J.
Youden and co-workers, see [5].
By testing in both configurations shown in Fig. 7 the upstream data (and the downstream data),
individually,; have the statistical independence requirement that is needed to apply the Youden procedure,
etc. The SFC unit shown in Fig. 7 is a super flow conditioner placed between the tandem meters, see [4].
It is intended to isolate the downstream meter from flow profile (or other anomalies) that might exist in the
laboratory pipeline that connects to the upstream meter.* Thus, the tandem meter configuration affords one
the opportunity of generating data both without and with pipeflow profile effects because downstream
meter and upstream meter performances can be treated separately. Comparisons can give unique global
insights into laboratory pipeflow phenomena without having to measure these distributions.
The types of flowmeters for this type of laboratory testing should be selected according to the
experiences of the participating laboratories. This consensus selection should produce the type of meter, the
size, manufacture, associated instrumentation, etc. This selection process should be extended to include the
fluid conditions, the flowrates, etc. as well as the tolerances to be used in arranging these.
The data generated via the round robin testing program is analyzed for each of the flowrates selected and
for each of the meter positions. For each of these conditions, plots are produced of the respective meter
performance characteristicsi.e., meter factor, discharge coefficient, etc., see [5, 6], Individual results, or
averages thereof can be plotted. Each point represents the combined results for both meters for each
laboratory.
The data processing procedures consist of determining median values for the respective sets of data for the
meters. By drawing horizontal and vertical lines through these median points, the plot is divided into four
Cartesian quadrants. The origin of this Cartesian system is, according to the available data, the best estimate
of the true values of the meter factors for the two meters tested according to the specified conditions, see
Fig. 8. In the northeast Cartesian quadrant, the data can be considered systematically inaccurate in that
points are each higher than those of the origin. Similarly in the southwest quadrant, points are lower. Thus,
the degree to which data is distributed in these quadrants is a measure of the systematic off-sets prevailing
in the laboratory data.
In the northwest and southeast quadrants the data can be considered inconsistent or random in that one
value is low while the other is high. Therefore, the degree to which the data is distributed in a northwest to
southeast manner about the median intersection is a measure of the random variation in the data.
The preferred result indicating good control would be to find that the measure of systematic distribution
(northeast to southwest) is equal to the random distribution (northwest to southeast) and that these measures
are acceptably small, see Appendix 2. The respective levels of uncertainty can be quantified.
Where, as is usually the case, the two meters are identical, a procedure for quantifying the respective
random and systematic levels of the data can be used as follows, see [5]. A line of slope +1 is drawn
through the intersection of medians on Fig. 8. The data is then projected perpendicular to and parallel along
this diagonal line. The respective projections are then used to produce standard deviations:
The ratio of these quantities produces the degree of ellipticity of the data.
When this ratio is larger than unity, the interpretation is that systematic variations prevail among the labs; this
is quantified by the magnitude of e. Analogous conclusions can be drawn for e<1.
Depending upon the results obtained for ellipticity, a number of reactions can occur. If e is large and this
is produced by one or more laboratories, then the reaction should be to examine the components of their
flow measurement processes to find systematic causes, etc. If e is small and this is produced by one or more
laboratories, the reaction should be to examine the components of their processes with respect to their
precision. If e is near unity but the levels of uncertainty are considered too large, then the appropriate
response would be for the labs responsible to search and repair the pertinent components.
When such search and repair efforts are completed, the round of tests should be repeated for the same
conditions so that improvements can be quantified . Even when such search and repair efforts are not
needed, repeat testing is needed to produce the continuous data record required by type 2 traceability.
162 GAS FLOW MEASUREMENT: CALIBRATION FACILITIES AND FLUID METERING TRACEABILITY AT THE
NATIONAL BUREAU OF STANDARDS
CONCLUSION
The standards philosophies for flowrate measurements have been presented, briefly. The specified gas flow
calibration facilities currently in operation at NBS at Gaithersburg, MD have been described. Levels of
performance have been given.
Techniques for establishing and maintaining flowrate measurement traceability have been presented. A
specific scheme has been described in some detail so that realistic data, produced on a continuing basis, can
be generated so that a laboratorys entire flowrate measurement process can be assessed.
It is concluded that once these types of traceability chains are produced so as to link flow measurement
laboratories within and across national borders and boundaries, satisfactory fluid measurements can be
achieved at specified levels. In this manner, the increasingly critical and costly measurements of gas
resources and products can occur satisfactorily in custody transfers and in industrial processes.
APPENDIX 1
GLOSSARY OF TERMS
ACCURACYThe closeness of the agreementusually expressed as a percentagebetween the result of
a measurement and the true value of the quantity being measured. Accuracy of flow measurement is
defined as the total uncertainty which consists of the sum of the systematic error, or bias, and the
precision.
PRECISIONThe closeness of the agreementusually expressed as a percentagebetween the results of
two or more measurements of the same (or similar) quantity being measured. Precision of flow
measurement is defined as the random uncertainty at the 95% confidence level in ASME-MFC-2M.
Example: Repeatability expresses how close duplicate measurements can be made to be.
method of measurement
observer
measuring instrument
location
conditions of use
163
time
LINEARITYIn flow metering, LINEARITY refers to the constancy of the meter factor over a specified
flowrate (or Reynolds number) range. This constancy is quantified by an uncertainty band specified by
the upper and lower limits of the meter factor over the specified range; the constant meter factor is
determined by averaging the upper and lower limits of the meter factor.
RANGEABILITYFlowmeter
rangeability is the ratio of the
maximum to minimum flowrates
specified by the meters linearity
(see above). Rangeability is
frequently termed turn-down.
TRACEABILITYTraceability to Type 1 Type 2 Type 3 Type 4
designated standards (national, Traceability is Measurement Traceability Traceability
international, or well characterized the ability to s have means the implies a
reference standards based upon demonstrate traceability to ability to capability to
fundamental concepts of nature) is conclusively designated relate express
an attribute of some that a standards if individual quantitatively
164 GAS FLOW MEASUREMENT: CALIBRATION FACILITIES AND FLUID METERING TRACEABILITY AT THE
NATIONAL BUREAU OF STANDARDS
measurements. However, there are particular and only if measurement the results of a
several interpretations or types of instrument or scientifically results to measurement
traceability, see [2]: artifact rigorous designated in terms of
standard has evidence is standards units which
either been produced on a through an are realized
calibrated by continuing unbroken on the basis of
a national basis to show chain of accepted
reference that the comparisons. reference
laboratory measurement standards,
(i.e., NBS), or process is usually
has been producing national
calibrated measurement standards.
against results (i.e.,
another data) for
standard in a which the
chain or total
echelon of measurement
calibrations, uncertainty
ultimately relative to the
leading to a designated
calibration standards is
performed by quantified.
the national
reference
laboratory
(i.e., NBS).
APPENDIX 2
TANDEM METER STATISTICS
Calibrating meters in tandem enables a number of checks to be made on the flowrate measurements, see [5, 6].
Besides affording the opportunity of having a redundant result for the same flowrate, the tandem meters can
produce not only on-line indications of relative meter performance, but also off-line assessments of
uncertainties associated with the meters themselves and the system in which they are being calibrated.
On-line Indications.Instantaneous meter responses from a tandem configuration of meters can be
compared via ratios or differences in order to assure that each meter is operating satisfactorily. By satisfactorily
is meant that current meter performance matches that obtained when the meter was calibrated previously.
When previous calibration data for tandem meter configurationsin a single laboratory or in a number of
laboratoriesis processed properly, expected values can be produced for the respective meter factor ratio, etc.
This expected value and the associated uncertainty can be used to evaluate the relative performance of these
meters when they are used in round robin calibrations.
Interpretations. When the ratio of meter response is found to differ from the expected value by more than
the expected tolerance, the interpretations can vary. For example, one is not sure which meter is the cause
for the difference; one is not sure of the reason for the deviant behavior. However, one can be sure that
something is sufficiently wrong that the calibration should not be continued until this situation is remedied.
When the relative meter performance produces the expected value, it is assumed that the prevailing meter
conditions satisfactorily duplicate those that occurred during previous calibrations. Intrinsic in this
165
assumption is that whatever meter anomalies that may occur, they do not occur simultaneously so as to
affect each meter in the same manner. Long term variations can be observed both in meter factor and in
relative meter performance data plotted in time-series format.
Statistics. For successive calibrations done for constant flowrate conditions, the meter factor results for
each meter can be processed to give averages and the total standard deviations, i.e.,
For each specific flowrate, the data from each tandem meter configuration, can be processed to give the
correlation coefficient, i.e.,
where subscripts 1 and 2 refer to the upstream and downstream meters, respectively. The total uncertainty
for each of the meters can be categorized according to that which is correlated with the other meter and that
which is uncorrelated. These components can be designated m and s respectively referring to the meter
and the system used for the calibration. These are quantified for each meter, via
and
so that
Analysis. The time series data traces for each meter should, via the above decomposition for m, indicate
valid expectation data to corroborate meter well-being during round robin tests as well as longterm
longevity. These results are critical to show what type of and perhaps when refurbishments are needed to
keep the artifacts in proper condition.
The values for s determined in each lab provide another interesting parameter for intercomparing
performances. These data, together with the results of the Youden analyses described above, further
establish the degree of agreements among participants.
ACKNOWLEDGMENT
The author acknowledges his predecessors at NBS who in the 1960s and before have designed, built, and
characterized the facilities and procedures described above. Of special significance in this group are the
efforts of M.R.Shafer and K.R.Benson; they have been essential in establishing and maintaining the high
reputation that the fluid flow group at NBS enjoys in the fluid metering communityboth national and
internationally.
166 GAS FLOW MEASUREMENT: CALIBRATION FACILITIES AND FLUID METERING TRACEABILITY AT THE
NATIONAL BUREAU OF STANDARDS
The author also acknowledges the fine secretarial efforts placed toward this product by Mrs.Susan
L.Johnson as well as her patience through it all.
REFERENCES CITED
1. Cameron, J.M., Measurement Assurance, U.S. National Bureau of Standards Int. Report No. 771240, April
1977.
2. Belanger, B.C., TraceabilityAn Evolving Concept, ASTM Standardization News, February 1979.
3. Mattingly, G.E., and Spencer, E.A., Steps Toward an Ideal Flow Transfer Standard, FLOMEKO Symposium,
Groningen, The Netherlands, 1978, published by North Holland Publishing Co., Amsterdam, NL.
4. Mattingly, G.E., Dynamic Traceability of Flow Measurements, Invited Lecture, IMEKO Tokyo Flow
Symposium, 1979, Society of Instrument and Control Engineers, Tokyo, Japan.
5. Youden, W.J., Graphical Diagrams of Interlaboratory Test Results, Journal of Industrial Quality Control, 15
(110, May 1959, pp. 133 137.
6. Strohmeier, W.A., Notes on Turbine Meter Performance, (unpublished treatise), TN #17, March 1971, Fischer
and Porter Co, Warminster, PA.
7. Mattingly, G.E., An Interlaboratory Round Robin Flowmeter Test Using Turbine Meters Flowing Water, in
preparation as a U.S. National Bureau of Standards Int. Report.
8. Mattingly, G.E. and Kinghorn, F.C., An NBS-NEL/UK Orifice Meter Crosscheck Program, see Mattingly, et
al., Workshop Report on Fundamental Research Issues in Orifice Metering, Gas Research Institute Report 84/
109, 1984.
9. Streeter, V.L., Fluid Mechanics, 5th edition, McGraw-Hill Book Co., New York, NY, 1971.
10. Ruegg, F.W. and Shafer, M.R., Flow Measurement: Procedures and Facilities at NBS, Proc. Semi-Annual
Meeting at ASHRAE, San Francisco, CA, 1970.
11. Olsen, L., and Baumgarten, G.P., Gas Flow Measurement by Collection Time and Density in a Constant
Volume, Proceedings Symposium on FlowIts Measurement and Control in Science and Industry, Paper No.
38138, Pittsburgh, PA, 1971.
12. Ruegg, F.W. and Johnson, O.P., Dynamics of the Bell Prover, Proceedings Symposium on FlowIts
Measurement and Control in Science and Industry, Paper No. 38152, Pittsburgh, PA, 1971.
13. Kieffer, L.J., ed., Calibration and Related Measurement Services at NBS, NBS Special Publication 250.
14. Mann, D.B., et al., Gas Orifice Meter Discharge Coefficients as Determined by Mass Flow Measurement, NBSIR
831685, August 1983.
CROSS REFERENCE SERVICE OF NATURAL GAS
STANDARDS IN THE UNITED STATES
Julia C.Shapiro, Ph.D.
Laboratory Manager
Gerald R.Burkett, N.B., B.S.
Plant Manager
William A.Crowley, M.B., B.S.
Operations Manager
Scott Specialty Gases, Inc.
Troy, Michigan 48083
ABSTRACT
The United States Natural Gas Industry requirements for high accuracy analysis of natural gas pointed out a
need for interlaboratory comparison of compositional analysis. Scott Specialty Gases, in response to this
need, has developed a Cross Reference Service to correlate analytical results between laboratories. The
statistically summarized results of the interlaboratory correlations have identified strong and weak points of
existing analytical techniques. The accuracy of analysis of specific components varies from a relative
standard deviation of 2% to as high as 20%. Although the Natural Gas Industry would like to analyze
energy to 1 BTU, the results of the Cross Reference Service indicate an accuracy of 2.5 BTU at a 95%
confidence level. The problems causing inter!aboratory disagreement are discussed with particular emphasis
on differences in analytical techniques, instrumentation, and absence of uniform standards throughout the
Industry.
The United States Natural Gas Industrys goal for precision in measurement of BTU is less than one BTU.
The need for such extreme accuracy equal to 0.1% can be understood from the magnitude of United States
natural gas consumption (Table 1).
TABLE 1
UNITED STATES 1984 NATURAL GAS MARKET
Energy, BTU, Quads (Billions) Dollar Estimate
Residential 7.4 43.73
Commercial 7.0 27.51
Industrial 3.2 11.62
Miscellaneous .5 0
168 CROSS REFERENCE SERVICE OF NATURAL GAS STANDARDS IN THE UNITED STATES
Estimates of United States gas production in 1984 are approximately 18 quadrillion BTU or 83 billion
dollars. In this case an error of one BTU has a potential of gains and losses to transmission and pipeline
companies and public utilities of 83 million dollars a year.
The extreme accuracy requirements of measuring BTU encouraged development of compositional analysis
of natural gas and calculation of the theoretical BTU value which is now the standard practice. The majority
of the Natural Gas Industry uses gas chromatography as a fast, efficient and reliable analytical technique.
There are several analytical procedures published; these include American Society for Testing and
Materials, Gas Processors Association, as well as those developed by various G.C. manufacturers and users.
Many G.C. manufacturers have developed instruments specially designed for natural gas analysis.
As it is known, one of the most essential factors in G.C. analysis is the existence of a reliable standard. Many
specialty gas companies, including Scott, provide gravimetric compositional standards. The accuracy of
standards available varies. A primary standard reference from the National Bureau of Standards has not
existed until recently.
Thus, all three factors mentioned above, various analytical techniques, different instrumentation and
absence of a primary standard reference material can cause a significant difference in analytical results
between laboratories.
The objective of implementation by Scott of the Natural Gas Cross Reference Service was to improve
interlaboratory correlation by allowing laboratories to compare themselves to others in the Industry.
The Natural Gas Cross Reference Service is performed on a quarterly basis. The process consists of:
The BTU Cross Reference Service cylinders are manufactured from a master cylinder containing at least 8
9 natural gas components in a Methane balance gas. This mixture is then transferred to 25 or more smaller
cylinders.
In the process of manufacturing, the major problems appear to be the same as has been met in the field:
transferring of natural gas mixtures without condensation, separation of heavy hydrocarbons, and pressure
and temperature changes which occur inside of the sample system.
Each sample cylinder was analyzed, in order to assure their homogenity, using a Varian Vista 6000 Gas
Chromatograph. When developing this technique we encountered the common G.C. problems: separation of
Ethane from Methane in the presence of 90% Methane, separation of Isobutane from Butane, Isopentane
from Pentane and condensation of higher hydrocarbons (Hexane, Heptane) on intermediate lines before
injection.
169
All hydrocarbons were analyzed using an 80/100 mesh n-octane on porasil C stainless steel column (61/
8) and a FID detector with temperature programming. The temperature is programmed from 30C (2
minutes) to 110 at 10C/min.
Nitrogen and Carbon Dioxide are analyzed on a Carbosieve S column (101/8) at 30C isothermally
using a TCD detector. Both analyses used Helium carrier gas at 30 ml/min., a 0.25 cc loop and a heated
valco valve. An external gravimetric standard was used for calibration throughout the process of analysis.
A sample of the chromatogram is shown in Figure 1.
This analytical procedure, along with proper manufacturing technique, gave us a guarantee of
homogenity of the gas with spread less than 0.5% relative standard deviation of each component from
cylinder to cylinder. This deviation includes uncertainties in transferring mixtures into cylinders and
uncertainties in the analysis (Table 2).
Each participant returns his analytical results to Scott for compilation. We normalize all of these results to
100%. All BTU values are recalculated using the GPA procedure. This process of compiling results is
necessary to make them comparable.
The data is then statistically summarized and the resulting report issued to subscribers. The report
consists of the following: All participants data normalized to 100% (Table 3), the statistical analysis of
reported results (Table 4). The statistical summary includes the mean, median, estimate of standard
deviation, estimate of standard error, number of observations and number of outliers.
The balance of the report includes histograms of the participants data. Figures 23 show sample
distributions for some components.
Besides the regular Cross Reference Service provided by Scott on a quarterly basis, we arranged in 1985
a Round Robin testing program among nine laboratories in the Natural Gas Industry. In this program a
cylinder with synthetic natural gas mixture was manufactured and analyzed by Scott, then sent to
participating laboratories for analysis and returned back to Scott for final analysis. The results were
published. Table 5 shows the precision of analysis by Scott and by the nine laboratories.
The results of all Cross Reference services (Table 6&7) which has been provided during the last two
years can be summarized in the following conclusions:
1. There is a gradual improvement in the analysis of most components in the last series of BTU Cross
Reference Services compared to the first. Especially significant are changes for Ethane, Propane,
Carbon Dioxide and Nitrogen.
2. The error in component analysis increases with carbon content of the molecule from 0.18% Relative
Standard Deviation for Methane to 52% for Hexane.
Table 2
Relative Standard Deviation from Cylinder to Cylinder for Each Component in One Series of BTU
Service (Analyzed by Scott).
Methane 0.38%
Ethane 0.31%
Propane 0.37%
Butanes 0.52%
Pentanes 0.46%
Hexane 0.53%
Nitrogen 0.24%
Carbon Dioxide 0.23%
170 CROSS REFERENCE SERVICE OF NATURAL GAS STANDARDS IN THE UNITED STATES
FIGURE 1
Sample of Chromatograms
171
TABLE 3
Tabulation of Reported Analytical Results
TABLE 4
Statistical Summary of Reported Analytical Results
Methane Ethane (Vol Propane Butane (Vol BTU (Vol
(Vol %) %) (Vol %) %) %)
No. of 14 15 15 15 14
Observ.
Min. 88.5243 4.8824 1.0362 .1620 1024.5400
Observed
Value
Max. 89.0780 5.1699 1.1406 .2601 1030.4699
Observed
Value
Mean Value 88.8917 4.9838 1.0725 .1931 1027.9697
Median 88.9406 4.9670 1.0670 .1840 1028.3449
Value
Scott Value 88.7845 5.0884 1.0691 .1768 1029.0400
Est. Std. .16105 .07412 .02668 .02619 1.64478
Dev.
Est. Std. .04304 .01914 .00689 .00676 .43959
Error
Coeffic. of .18118 1.48730 2.48729 13.56396 7.65446
Variance
(%)
No. of 1 0 0 0 2
Outlying
Values
172 CROSS REFERENCE SERVICE OF NATURAL GAS STANDARDS IN THE UNITED STATES
FIGURE 2
Frequency Distribution of Reported AnalysesHexane (Vol %)
FIGURE 3
Frequency Distribution of Reported AnalysesN2 (Vol %)
TABLE 5
3. The largest errors were observed for components requiring accurate G.C. separation technique, as
isobutane and n-butane, iso-pentane and n-pentane. The combined error for the sum of Iso-butane and
n-butane and sum of iso-Pentane and n-Pentane is significantly less than for the individual components.
The high relative standard deviation for Hexane is explained by the fact that some customers analyze
heavy hydrocarbons as Hexane+ mixtures, some analyze them separately.
4. Despite the relatively high error in minor components approaching 2030% relative standard deviation,
the process of calculating BTU value from compositional analysis results in a relative standard
deviation of 0.16%.
5. The analysis of BTU value show a significant improvement in relative standard deviation from 0.47%
two years ago to 0.16% most recently.
Table 6
Relative Standard Deviation % for All Components in Seven Cross Reference Services
BTU BTU BTU BTU BTU BTU BTU
Component #1 #2 #3 #4 #5 #6 #7
Methane 0.21 0.25 0.36 0.17 0.32 0.16 0.18
Ethane 8.25 3.68 2.45 1.65 2.26 2.22 1.49
Propane 6.41 9.11 2.68 2.19 6.40 1.84 2.49
Iso-butane 5.22 7.70 30.91 3.11 10.86 13.56
n-butane 20.86 8.57 20.23 23.56 7.65
Butanes 7.8 4.8 7.6 4.60
Iso-Pentane 18.09
n-Pentane 28.20 9.14 26.35 69.52
Pentanes 14.50
Hexane 19.03 10.87 50.29 20.37 52.10
174 CROSS REFERENCE SERVICE OF NATURAL GAS STANDARDS IN THE UNITED STATES
6. All observed Industrys errors were much higher than Scotts estimated accuracy. In an attempt to
rationalize the high errors of compositional analysis with the relatively low errors in BTU analysis the
following model of contributing BTU errors from component analysis was developed (Table 7). The
Table shows that at 95% Confidence level (assumed two standard deviations), Scotts precision for
mixtures of 1028 BTU is estimated at 0.40 BTU compared to the Industrys 2.5 BTU.
7. Although Nitrogen has a relative standard deviation of 2% which is significantly less than many of the
heavy hydrocarbons, it was the largest contributor in BTU error because it has no heating value.
Table 7
Comparison of Standard Deviation of BTU for Scotts and Industry Analysis of Natural Gas
Industry Precision Scott Precision
Mean Std. Contr Contri Mean Std. Contr Contri
% Dev. ib. in b. in % Dev. ib. in b. in
BTU BTU BTU BTU
of of
Std. Std.
Dev. Dev.
C1 88. 1009 88. 1009
93 .7 77 .7
C2 4.98 0. 37. 0.56 5.09 0. 38. 0.
074 80 0193 64 146
C3 1.07 0. 16. 0.40 1.07 0. 16. 0.
027 18 0033 13 050
C4 0.40 0. 8.99 0.47 0.39 0. 8.77 0.
021 0020 045
C6 + 0.03 0. 1.34 0.49 0.06 0. 2.43 0.
012 0004 015
N2 4.03 0. 40. 0.79 4.05 0. 40. 0.
079 65 0122 89 123
CO2 0.56 0. 5. 0.27 0.57 0. 5. 0.
027 61 0015 75 015
BTU 1027 1. 1028 0.
.81 28* .33 20*
Estimated Accuracy of BTU Analysis (95% 2.5 0.4
Confidence at 2% Standard Deviation) BTU BTU
175
8. The fact the Industry precision is much lower than Scotts can be explained by three factors contributed
to it: various analytical instrumentation, different analytical techniques and absence of a Primary
Standard. Table 8 shows the technique and instrumentation employed by the participants. Some
participants used regular G.C.s, some dedicated natural gas chromatographs. There were analysis done
at isothermal, as well as T-programming conditions. Most participants analyzed the mixtures on two
columns, but some used as many as four columns.
Table 8
Analytical Technique Used by Participants
Number of Participants Instruments Amount of Columns Detectors Conditions
3 G.C. 2 TCD Isotherm
8 G.C. 2 FID & TCD TProgr.
1 G.C. 4 FID & TCD TProgr.
3 G.C.Carle In Series
1 Gas Monitor Dedicated BTU Analyzer
CONCLUSIONS
Two years of providing the Cross Reference Service has proved the fol lowing:
ABSTRACT
The paper describes a new and unique design of a primary Gas Flow Calibrator. It is an automatically
controlled precision volumetric flowmeter calibrating device specifically designed for use with a variety of
gases over a wide range of pressures. The Aerotrak is a closed loop positive displacement system able to
minimize both the quantity of gas used and the energy required to create the desired flow rate. The entire
operation of the Aerotrak is under the automatic control of a uniquely programmed Personal Computer
(PC). When initiated by the operator, the pre-selected program ensures the calibration data is taken after the
pressure and temperature surge created by the initial piston motion has completely decayed and the flow
rate is constant. This is achieved by the computer comparing successive calibration points and accepting
data only when it has repeated within specified limits. As the actual data is being generated, it is
continuously displayed for the test operator and stored in memory. Upon completion of the test, all data can
be viewed on the computer screen by the operator and immediately evaluated. The completed data is then
stored on a diskette which can be used to generate hard copy printouts and the plots of curves.
DESCRIPTION
The Aerotrak Gas Calibrator design, not a modification of some existing calibration technique, is a new and
truly unique approach to Gas Calibration. It is a closed loop positive displacement calibrator, combined with
this new design concept is a powerful marriage with a Personal Computer and menu driven software
program. The program automatically controls the total operation of the calibrator. In addition to rapid data
reduction the PC Screen displays Final Test Report and Curves. This new Closed loop principle affords the
user an opportunity to calibrate both gas and liquid with the same basic system. However, this paper will
address only the Gas Application.
177
OPERATION
The system is charged with the selected gas ranging in pressure from 5 psia through 1440 psig @ 100
degrees F. The gas flow is created by a solid sealed piston which is moved through the length of a bored and
honed flow tube with 12 RMS finish. The preselected velocity of the piston is established by a servo
controlled motor. A rotary encoder mounted on the motor shaft provides the feedback necessary for
constant rate control of the advancing piston. (Figure 1) The flow transducer under test is installed in an
external flow path with the upstream and downstream legs geometrically symmetrical. As the piston is
advanced it creates the gas flow through the flow transducer and then to the upstream side of the piston in
the flow tube. At the time of initial motion of the piston a pressure/temperature surge is experienced by the
flow transducer. As the pressure/temperature surge decays a steady state flow condition exists at the
flowmeter. The Computer samples the variables required to make the flow rate calibrations such as
transducer frequency, encoder frequency, pressure, temperature, delta pressure, and delta temperature.
Successive calibration points are calculated by the PC and when repeatability at the desired flowrate is
achieved in a selected number of points the data is stored and the velocity of the piston is automatically
changed to the next desired calibration point. This pattern is repeated until the required number of
preselected consecutive points are gathered and are repeatable within the desired limit.
When the piston reaches the extreme downstream portion of the flow tube, a motor driven ball valve in
the return line is opened and the gas is returned to the upstream side of the sealed piston while the piston is
being moved to its original starting position. It is then ready for another calibration run.
SYSTEM CHARACTERISTICS
The advantages of the closed loop gas calibration are as follows :
A. Minimizes the amount of gas required for test. The system is charged to the required pressure and
remains at that pressure level throughout the test.
B. Minimizes the amount of energy required to create desired flow rate at working pressure.
C. Capable of calibrating flowmeters from partial vacuum to 1440 psig.
D. Capable of utilizing a variety of calibration gases.
E. Capable of calibrating at required operating densities with a selected gas.
F. Easily checked for seal leaks.
G. Time required for calibration is reduced to a few minutes versus hours for the present conventional
methods.
H. Rapid change from one density to another.
I. Does not require correction for changes in atmospheric pressure.
J. Provides a high degree of consistency in Test Program through standardization of technique.
K. Improved ease of operation by less skilled people.
L. The symmetrical design of the flow paths allows flowmeters to be placed in a position which
minimizes the amount of pressure/temperature correction required.
M. The displacement is determined by conventional water draw technique using test measures traceable to
National Bureau of Standards.
178 NEW CONCEPTS IN GAS CALIBRATION
FIGURE 1
SOFTWARE PACKAGE
Upon completion of the automated calibration runs the raw and calculated data is displayed on the Computer
Screen. The operator is afforded the opportunity to immediately view and approve the test results. The
completed calibration data is stored on a diskette and then used to generate hard copy print-outs and plots of
curves. (Figure 2)
The Aerotrak Gas Calibrator is capable of determining the changes in flowmeter calibration
characteristics, where the calibration charge pressure is changed from one level to another. The test data is
stored, resulting from a test at one pressure level. The calibrator is pressurized at another level and an
identical test is conducted. The PC has the capability of plotting both curves on the PC Screen, or generating
a hard copy via a plotter. (Figures 3, 4 and 5) The operator has the option to view a variety of plots on the
179
FIGURE 2
PC Screen. The variables includes frequency, K-factor, flow rate, density, linearity limits, and time.
Additionally the operator may select his units of volume and time.
TYPES OF TRANSDUCER
The Aerotrak has an inherent capability to calibrate a variety of flow transducers, such as turbine, variable
area, nozzles, vortex shedders, orifice plates, laminar, thermal mass flow controllers.
The type of inputs include both frequency and non-pulsing analog inputs such as 0 to 5 VDC, 4 to 20 MA
or 10 to 50 MA. Manual inputs are required for the variable area flowmeters.
FUTURE DEVELOPMENTS
Development work is being carried on to drastically increase the maximum flow rate capability. This
increase in flow rate is required to support the needs generated for the Natural Gas Industry.
180 NEW CONCEPTS IN GAS CALIBRATION
FIGURE 3
FIGURE 4
181
FIGURE 5
FIGURE 6
MICROSTRUCTURE SENSORS FOR FLOW,
DIFFERENTIAL PRESSURE AND ENERGY
MEASUREMENT
R.Higashi, R.G.Johnson, A.K.Mathur, A.N.Pearman, and U.Bonne
Honeywell Inc., Physical Sciences and Technology Centers
Minneapolis, Minnesota
ABSTRACT
The point measurement of velocity of gaseous fluids has been made for some time with hot wire
anemometer type sensors. We have developed a microflow sensor on silicon which features a wide dynamic
range (14000 feet/min), fast response (5 msec), low operating power (~10mW), and batch fabrication for
reproducibility and cost effectiveness. Its small size and low power dissipation make it well suited for a
velocity sensor to indicate mass flow or differential pressure across a small orifice. Theoretical aspects of
this approach and laboratory experiments to characterize the performance of this interesting microsensor are
discussed. Safety test results are reported. We are also exploring the sensitivity of certain micro-sensors to
variations in gas properties such as composition, gas density, specific heat, and viscosity. This sensitivity to
gaseous fluid parameters might form a basis for the measurement of energy flow under advantageous
conditions of automatic compensation for pressure and temperature changes. The Gas Research Institute
sponsored part of this work involving correlations between various natural gas properties.
INTRODUCTION
The micromachining of small structures in silicon became an attractive approach to the development of new
types of microtransducers following publication of papers by Bassous(1), Bean(2) and Peterson(3) in 1978.
These papers outlined the principles and methods for precision anisotroplc etching of single crystal silicon
and presented many examples of structures fabricated by these techniques. Through innovations on this
early work, we have developed techniques for the fabrication of precisely dimensioned dielectric film
structures containing temperature sensitive resistors that can be thermally isolated from the chip. This
development has enabled locally high temperatures to be attained with very low input power and little
heating of the chip. It has also led to novel concepts of integrated thermal sensors and transducers that can be
183
built with the low-cost, thin-film batch processing characteristic of integrated circuit fabrication. In
addition, there is the option of incorporating active silicon circuit elements on the chip with the
microtransducer, thus achieving a larger scale device integration with lower cost, lower device size, and
easier applicability. These expectations are now close to being realized in practical devices at Honeywell
with the development of an air flow and differential pressure sensor. This paper explores how these
techniques may be used for natural gas flow, differential pressure and energy flow measurement.
DISCUSSION
FIGURE 3. HEATER AND SENSOR CIRCUITS FOR THE AIR FLOW SENSOR FOR MASS FLOW
Performance Characteristics
An outstanding property of the sensor is the large temperature differential that develops between the two
detector resistances with only small air flows, thus making it practical to use a simple alloy film to sense
187
CONCLUSIONS
We have developed a novel, highly-sensitive air or gas flow sensor which performs well as a mass flow
sensor and differential pressure sensor. It is especially suited to applications in the low differential pressure
range from 0 to 1.0" of water column.
It provides a more direct approach for temperature and pressure compensation than other presently-
available mass flow sensors requiring measurement of temperature and pressure. For some gas mixtures of
varying composition, mass flow is indicated accurately (e.g. CO2 and He) without calibration corrections.
Because it can be fabricated by conventional thin film deposition and silicon processing techniques. It offers
the possibility of lower cost and broader applications than present commercially available gas flow sensors.
Mixtures of other gas constituents require corrections. It appears to be possible to generate these
corrections (using auxiliary real time measurements) to provide a mass flow output under varying
temperature, pressure and composition conditions. Refinements of this approach may enable a similar
measurement of energy flow in a natural gas stream. We are currently studying these approaches.
189
FIGURE 6. RESPONSE TO MASS FLOW IN A TYPICAL SMALL CHANNEL FOR AIR AND CO2
Because this sensor can be fabricated by conventional thin film deposition and silicon processing
techniques, it offers the possibility of lower cost and broader applications than present commercially
available gas flow sensors.
REFERENCES
1. E.Bassous, Fabrication of Novel Three Dimensional Microstructures by The Anlsotroplc Etching of (100) and
(110) Silico. IEEE Transactions on Electron Devices, ED-25. No.10, 11781185 (1978).
2. K.E.Bean, Anisotropic Etching of Silicon, Ibid., p. 1185.
3. K.E.Peterson, Dynamic Micromechanics On Silicon: Techniques and Devices , Ibid., p. 1241.
4. B.Lewis and G. v.Elbe, Combustion Flames and Explosions of Gases, 2nd Ed., Acad. Press, NY and London,
(1961), pp. 323346.
UB/jh IGT.wp
041686
190 MICROSTRUCTURE SENSORS FOR FLOW, DIFFERENTIAL PRESSURE AND ENERGY MEASUREMENT
FIGURE 9. GAS HEATING VALUE VERSUS MOLECULAR WEIGHT OF NATURAL GAS SAMPLES
SUPPLIED BY GRI
192 MICROSTRUCTURE SENSORS FOR FLOW, DIFFERENTIAL PRESSURE AND ENERGY MEASUREMENT
FIGURE 10. PLOT OF GAS HEATING VALUE VERSUS CORRECTED SPECIFIC GRAVITY FOR GRI GAS
SAMPLES
THE SMART-CAL CUTLER HAMMER CALORIMETER
COMBINATION FOR BETTER PERFORMANCE AND
DATA PROCESSING
Alfred F.Kersey
Gas Industry Manager
Fluid Data, Inc.
1844 Lansdowne Avenue
Merrick, New York 11566
Figure 1
ABSTRACT
Ever since its invention in 1921, the Cutler Hammer recording calorimeter has utilized a stripchart recorder
to display its instantaneous BTU and to provide a continuous BTU record. In the early years, the BTU
record was merely for information, to check manufactured gas and gas mixing processes, or to assure that
BTU minimums are met. In this day of MMBTU, the BTU is a major component in the cost of gas sales.
Those people using Cutler Hammer Calorimeters use the BTU information in the following different ways :
To review the operation of the tank unit, Figure 1 is a pictorial view of the tank unit. This you have seen
before. The important features of this tank unit include:
The inputs to SMART-CAL are the inlet and outlet thermometers (RTDs) of the tank unit. Measuring the
resistance difference between these two thermometers, a transmitter in SMART-CAL generates an analogue
output proportional to the resistance difference. This analogue output is proportioned to BTU. Then an
analogue to digital converter sends a digital output proportional to BTU to the microprocessor.
The SMART-CAL keyboard provides operational directives to the microprocessor:
It is appropriate to point out that there are two calibration techniques used with SMART-CAL. One
technique is used for start up and for periodic service such as that done on a six month basis. The second
technique is the one used for auto-calibration.
195
Photo 1
The start-up calibration and periodic service calibration uses cold balance and certified gas to position the
zero and span of the performance curve of the instrument. A cold balance switch introduces into the
circuitry a resistor network. This is necessary because of the higher degree of curvature of the performance
curve as the outlet thermometer approaches the cold condition. A zero adjustment is made after the outlet
thermometer is sufficiently cool. Then the instrument is put on certified gas and allowed to come up to heat.
At this point, a keyboard adjustment is made so that the SMART-CAL display indicates the certified
calorific value. The keyboard is used again to put the calorimeter back onto line gas. Auto calibration is done
without operator assistance. The microprocessor will control the transfer from line gas to calibrating gas.
After an appropriate time for the instrument to stabilize on calibrating gas, the microprocessor will note any
deviation and correct the SMART-CAL reading. Then automatically, the calorimeter will go on to line gas
and after an appropriate period of time, the calorific values will again be used for averaging. The
improvements in accuracy which we expect to achieve with SMART-CAL come from the more frequent
calibra-tion and from the averaging. Whereas most of our users calibrate weekly and some calibrate as
infrequently as monthly, automatic daily calibration should achieve a higher degree of precision or at least a
higher degree of confidence level in the measured calorific value. The automatic averaging provided by
SMART-CAL should achieve a higher degree of accuracy than the eyeballing of a stripchart or even the
electronic chart averaging. Chart errors due to chart expansion and contraction are eliminated. We are sure
that those persons who use SMART-CAL will achieve our improved performance claims and feel their
money was well spent.
A NEW ON-LINE TECHNIQUE FOR NATURAL GAS
CALORIMETRY
Jag J.Singh, Ph.D.
Danny R.Sprinkle
Richard L.Puster
NASA Langley Research Center
Hampton, Virginia 23665
ABSTRACT
As a spin-off of a system developed for monitoring and controlling the oxygen concentration in the
Langley 8-Foot High-Temperature Tunnel, a highly accurate on-line technique has been developed for
determining heats of combustion of natural gas samples. It is based on measuring the ratio m/n, where m is
the (volumetric) flowrate of oxygen required to enrich the carrier air in which the test gas flowing at the rate
n is burned, such that the mole fraction of oxygen in the combustion product gases equals that in the carrier
air. The m/n ratio is directly related to the heats of combustion of the saturated hydrocarbons present in the
natural gas. A measurement of the m/n ratio for the test gas can provide a direct means of determination of
its heat of combustion by using the calibration graph relating the m/n values for pure saturated
hydrocarbons with their heats of combustion. The accuracy of the technique is determined solely by the
accuracy with which the flowrates m and n can be measured and is of the order of 2 percent in the present
study. The theoretical principles and experimental results are discussed.
INTRODUCTION
We recently developed a system for monitoring and controlling the oxygen concentration in the Langley 8-
Foot High-Temperature Tunnel (ref. 5). It is based on a y2O3-stabilized ZrO2 electrochemical sensor, The
system is capable of maintaining oxygen concentration at 20.91.0 percent in the methane-oxygen-air
combustion product gases. During the development of the system, it was noted that the degree of the
required oxygen enrichment of the air was very strongly dependent on the purity of the combustible gas
(CH4). For example, it was noted that the presence of noncombustible componentssuch as N2, CO2, or H2O
noticeably affected the amount of oxygen that needed to be added to the air to make the mole fraction of
oxygen, X(O2), in the combustion product gases equal to that in the standard air. It was quickly realized that
197
the reverse was also true, that is, the purity of the combustible test gas could be inferred by measuring the
amount of oxygen needed for X(O2) equalization (ref. 6). It is now demonstrated that the technique can be
further extended to infer the presence of heavier saturated hydrocarbons in the combustible test gas (natural
gas) as well. It is assumed that saturated varieties are the only types of hydrocarbons found in the natural
gas samples. According to reference 3, saturated hydrocarbons are the predominant varieties present in U.S.
natural gas samples. Since the heat of combustion of natural gas depends on its effective hydrocarbon
content , measurement of the amount of oxygen needed for X(O2) equalization can be used for direct
determination of the thermal content of the test gas (natural gas). Details of the theory of operation of the
new system and the experiments conducted to verify its accuracy are discussed in the following sections.
The heats of combustion of gaseous hydrocarbons are presently determined by using a constant pressure
flame calorimeter (ref. 8). However, calorimetric measurements cannot be made on-line and require
information about the thermal properties of the combustion products of the test sample. The technique reported
here, on the other hand, is direct, can be performed on-line, and requires no prior knowledge about the
composition of the test sample.
SYMBOLS
A depends only on the composition of the test gas and the mole fraction of oxygen in the air used
for combustion.
CxHy Hydrocarbon (for saturated hydrocarbons, y=2x+2)
f Combustible fraction of test gas
I Noncombustible impurities (such as N2, CO2, and H2O) in test gas
Volumetric flowrate of carrier air stream
m Volumetric flowrate of oxygen
n Volumetric flowrate of test gas (.mixture of saturated hydrocarbons and noncombustible
impurities)
sccm Standard cubic centimeters per minute; values listed are for 20C and 101.3 kPa
X(O2) Mole fraction of oxygen
m/n for X(O2)=0.2095 (standard air)
H Heat of combustion
THEORETICAL PRINCIPLES
A general expression for the combustion of a natural gas sample in oxygen-enriched air can be written as
follows:
(1)
where
198 A NEW ON-LINE TECHNIQUE FOR NATURAL GAS CALORIMETRY
(2)
If X(O2)=0.2095, we obtain
(3)
If f=1(i.e., the test gas has no noncombustible impurities), equation (3) reduces to
(4)
This equation is identical to equation (6) in reference 6. If, on the other hand, f=0 (i.e., no combustible
fraction is present in the test gas), equation (3) reduces to
(5)
Generalizing equation (3) for nonstandard air, we obtain
(6)
The values of m/n for some of the pure saturated hydrocarbons in standard and nonstandard air are
summarized in Table I.
Figure 1 shows the correlation between A and m/n for selected saturated hydrocarbons. It is apparent that
A and m/n are linearly related. If f1, m/n values for various impurity-containing hydrocarbon gases will be
different from those for pure hydrocarbons. An experimental measurement of m/n will then give f, the
combustible fraction in
TABLE I. SUMMARY OF m/n VALUES FOR SELECTED SATURATED HYDROCARBONS [X(O2)=0.2042 and 0.
2095]
Hydrocarbon Chemical Formula m/n for
X(O2)=0.2042 X(O2)=0.2095
Methane CH4 2.770 2.795
Ethane C2H6 4.783 4.825
Propane C3H8 6.796 6.855
199
the test gas. The correlation between A and m/n for binary gas mixtures is shown in figure 2. Figures 1 and
2 clearly demonstrate that the m/n values for gases containing saturated hydrocarbons are uniquely related
to their hydrogen and carbon contents.
If the test gas is not a pure single hydrocarbon but is a mixture of two or more hydrocarbons, equation (6)
can be used to readily calculate the m/n value for effective test hydrocarbon. For example, for a test gas
containing equal mole fractions of CH4 and C2H6 , the effective equivalent hydrocarbon would be C1.5H5.0,
giving m/n=3.81 for X(O2)=0.2095. If this mixture also contained an incombustible impurity, the
corresponding m/n value would be lower, as indicated by equation (6). Figure 3 shows A as a function of m/
n for f 1 for test gases containing several saturated hydrocarbons as well as noncombustible gases. Again
the uniqueness of the correlation between A and m/n is evident.
Because m/n values for various test gases containing saturated hydrocarbons are related to their chemical
composition, they can serve as the basis for direct determination of heats of combustion. Table II lists the
gross heats of combustion of several pure saturated hydrocarbons (refs. 1, 2, 4, 9).
Figure 4 shows heat of combustion (in kilocalories per mole) versus m/n value for several selected
saturated hydrocarbons. Similar results for mixtures containing selected saturated hydrocarbons and
noncombustible gases are illustrated in figure 5. It is apparent that the heats of combustion of various gases
are directly related to their corresponding m/n values. An experimental determination of m/n for the test gas
is, therefore, expected to provide an on-line determination of its heat of combustion.
Figure 1. A as a function of m/n for pure unbranched acyclic hydrocarbons. X(O2)=0.2042; A=4X(O2) (1f) + f{4x+[1
+X(O2)]y}
Hydrocarbon m/n [X(O2)= 0.2095] H, kcal/mol kcal/mol
C3H8 6. 855 530.61 77.40
201
Figure 2. A as a function of m/n ofr binary of saturated hydrocarbons and noncombustable gases. X(O2)=0.2042; A=4X
(O2) (1f) + f{4x+[1+X(O2)]y}
Figure 3. A as a function of m/n for complex mixtures of saturated hydrocarbons and noncombustible gases. X(O2) =0.
2042; A=4 X(O2) (1f)+f{4x+[1+X(O2)]y}.
Hydrocarbon m/n [X(O2)= 0.2095] H, kcal/mol kcal/mol
C6H14 12.945 1002 .55 77 .45
Figure 4. Heats of combustion versus m/n values for saturated hydrocarbons. X(O2)=0.2042.
The oxygen flowrate (m) was adjusted until the ZrO2 sensor output matched that for air. These
204 A NEW ON-LINE TECHNIQUE FOR NATURAL GAS CALORIMETRY
Figure 5. Heats of combustion versus m/n values for gas mixtures containing saturated hydrocarbons and
noncombustible impurities. X(O2)=0.2042.
205
measurements were repeated for a number of hydrocarbon flowrates (n) while the air flowrate ( ) was held
constant. It should perhaps be emphasized that n in the parameter m/n represents the volume flowrate for
the test gas rather than the conventional mass flowrate. It will therefore be necessary to use a volume flowmeter
for metering the test gas flowrate. We used a positive displacement dry test meter for measuring the true
volume flowrate (n) of the test gases. A dry test meter was preferred over the wet test meter, since the latter
would allow the test gases to come in contact with water (or some other selected fluid) during passage
through the meter and thereby affect the combustible fraction in the test sample. Three gases with widely
different thermal characteristics were used to measure the accuracy with which the dry test meter measured
their flowrates. The data summarized in Table III demonstrate that the dry test meter gives as accurate a
volume flowrate value as the widely used thermal mass flowmeters. A comparison of the experimental and
the calculated values for various saturated hydrocarbons is given in Table IV.
TABLE III. COMPARISON OF DRY TEST METER AND THERMAL MASS FLOWMETER FLOWRATES IN
THE RANGE OF 5001500 seem
Test Gas Flowrates, sccm, measured by
Dry Test metera Thermal mass Flowmeterb
Air 999.3+10.0 994.6+10.0
792.3+10.0 794.7+10.0
651.8+10.0 646.0+10.0
502.7+10.0 499.9+10.0
Helium 1400.0+10.0 1413.3+14.3
1118.7+10.0 1119.3+14.3
840.7+10.0 842.1+14.3
557.6+10.0 558.1+14.3
Carbon Dioxide 729.0+10.0 731.9+ 7.4
636.4+10.0 629.3+ 7.4
518.5+10.0 512.8+ 7.3
aErrors in the dry test meter flowrates are based on uncertainties in the time required for the flow of preset volumes.
bErrors in the mass flowmeter flowrates represent 1 percent of the full scale of the meter (Full scale=1000 sccm).
207
TABLE IV. SUMMARY OF EXPERIMENTAL AND CALCULATED m/n VALUES FOR SELECTED
HYDROCARBONS IN AIR
[X(O2)=0.2042]
Test Hydrocaron Hydrocarbon Equalizing Oxygen Carrier Air Flowrate ,a m/n value
Flowrate,a n ,sccm flowrate ,a m, sccm , seem
Experimental Calculated
(from Eq. (6))
CH4 71.800.72 200.801.00 500.0 2 .797 0.042 2. 770
C2H6 45.850.46 214.671.00 500.0 4.6820.070 4.783
C3H8 29.180. 30 199.711.00 500.0 6.8430.103 6.796
C4H10 24.200 .24 213.001.00 500.0 8.8010.132 8.809
aThe seem values are for 20C and 101.3 kPa. The accuracies of the flowrates reflect 1 percent of the full scale of the
flowmeters.
TABLE V. SUMMARY OF EXPERIMENTAL AND CALCULATED m/n VALUES FOR VARIOUS TEST GAS
MIXTURES (COMPLETED)
[X(O2=0.2042)]
Test Gas Mixture, Mixture Flowrate,a Equalizing Oxygen Carrier Air m/n Value
Percent Volume n, sccm Flowrate ,a m, sccm Flowrate,a , sccm
Experimental Calculatedb
Complex Mixturesc
44.63%C2H6+25. 39.7+0.4 199.0+1.0 500.0 5.014+0.075 4.894+0.083
88%C3H8+ 10.81%
C4H10+5.09%CO2+
13.59% N2
53.04%CH4+26. 49.9+0.5 198.0+1.0 500.0 3.968+0.060 3.975+0.034
09%C2H6+ 18.42%
C3H8+1.43%CO2+
1.01% N2
50.84%CH4+17. 50.3+0.5 193.0+1.0 500.0 3.837+0.057 3.9360.046
12%C2H6+ 24.87%
C3H8+3.34%CO2+
3.83% N2
51.51%CH4+21. 49.2+0.5 199.5+1.0 500.0 4.055+0.061 4.070+0.036
24%C2H6+ 23.82%
C3H8+1.74%CO2+
1.69% N2
aThe seem values are for 20C and 101.3 kPa. The accuracies of the flowrates reflect 1 percent of the full scale of the
flowmeter.
bThe errors in the calculated values results from errors in the mixture composition.
cThe accuracies of the concentrations are of the order of +1 percent of the values listed.
TABLE V. SUMMARY OF EXPERIMENTAL AND CALCULATED m/n VALUES FOR VARIOUS TEST GAS
MIXTURES (CONT.)
208 A NEW ON-LINE TECHNIQUE FOR NATURAL GAS CALORIMETRY
[X(O2=0.2042)
Test Gas Mixture Mixture , Flowrate,a Equalizing Oxygen Carrier Air m/n Value
Percent Volume n, sccm Flowrate ,a m, sccm Flowrate, a , sccm
Experimental Calculatedb
Binary Mixtures
50.10% CH4+49. 96.00+0.83 362.3+1.0 500.0 3.774+0.043 3.770+0.044
90% C2H6 68.70+0.75 326.3+1.0 500.0 4.751+0.066 4.783+0.065
50.19% CH4+49. 56.18+0.75 322.0+1.0 500.0 5.732+0.092 5.7890.094
81% C3H8 52.58 0.53 353.0+1.0 500.0 6.713+0.087 6.740+0.030
50.40% CH4+49.
60% C4H10
51.39% C2H6+48.
61% C4H10
50.13% CH4+49. 100.30+1.23 153.5+1.0 500.0 1.530+0.028 1.517+0.034
87% N2 100.40+1.01 153.3+1.0 500.0 1.527+0.025 1.5150.031
50.08% CH4+49.
92% CO2
49.92% C2H6+50. 99.80+1.10 252.2+1.0 500.0 2.526+0.038 2.516+0.026
08% N2 99.90+0.84 253.0+1.0 500.0 2.531+0.031 2.514+0.023
49.87% C2H6+50.
13% CO2
49.96% C3H8+50. 99.90+1.05 353.3+1.0 500.0 3.536+0.040 3.524+0.021
04% N2 100.00+0.78 354.3+1.0 500.0 3.542+0.037 3.521+0.018
49.91% C3H8+50.
09% CO2
(7)
where
a0=23.2134
a1=91.2088
a2=2.9745
a3=0.3032
a4=0.0117
In developing this equation, a statistical weight of 5 was assigned to
to reflect the fact that the heat of combustion of a
noncombustible mixture is definitely zero, whereas the heats of combustion of other mixtures are not known
as accurately. A comparison between the heat of combustion values determined from experimentally observed
m/n values and those calculated from known chemical compositions is given in Table VI. It is apparent from
the results summarized in Table VI that the agreement between the experimental and the calculated values of
heat of combustion for the various gas mixtures is excellent.
209
TABLE VIII. COMPARISON OF COMPUTED AND EXPERIMENTALLY DETERMINED VALUES OF m/n AND
HEAT OF COMBUSTION FOR THE NATURAL GAS SAMPLE
Parameter Computed Experimental
m/n 2.840.03 2.850.01
H , kcal/mol 218.82.2 218.51.1
and experimentally determined values of the gross heat of combustion. The agreement between
corresponding values is excellent.
CONCLUDING REMARKS
A new technique has been developed for determining heats of combustion of test gases containing saturated
hydrocarbons. It is based on the measurement of the m/n ratio, where m is the volumetric flowrate of
oxygen needed to enrich the carrier air in which the test gas flowing at the rate n is burned, so that the mole
fraction of oxygen in the combustion product gases equals that in the carrier air. The m/n values are directly
related to the heats of combustion of the test gases. The accuracy of the derived values of heat of
combustion is determined solely by the accuracies with which the flowrates m and n can be measured. At
the flowrates used in the present study, the respective accuracies are of the order of 1 percent. This leads to
an error in the heats of combustion of the order of 2 percent.
The heats of combustion of hydrocarbons are presently determined by using a constant volume bomb
calorimeter for liquids and solids and a constant pressure flame calorimeter for gases. These measurements
can be very accurate (< 1 percent), since they depend mainly on the bath temperature measurement.
However, calorimetric measurements cannot be made on-line and require information about the thermal
properties of the combustion products of the test sample. The technique reported here, on the other hand, is
direct, can be performed on-line, and requires no prior knowledge about the exact composition of the test
sample. (The only assumption made regarding the composition is that saturated hydrocarbons are the only
combustibles present in the test samples). It thus appears that this new technique may be more useful for
field operations where on-line measurements of the heats of combustion of the test gases are often needed.
REFERENCES
1. Green, Don W., ed.: Perrys Chemical Engineers Handbook, Sixth ed. McGraw-Hill, Inc.(1984).
2. McCracken, Dudley J.: Hydrocarbon Combustion and Physical Properties. BRL Rep. No. 1496, U.S. Army,
Sept. (1970). (Available from DTIC as AD 714 674).
211
3. Miller, Richard D.; and Hertweck, Floyd R., Jr.: Analyses of Natural Gases, (1982). Info. Circ. 8942, Bureau of
Mines, U.S. Dept. Interior.
4. Rose, J.W.; and Cooper, J.R., eds.: Technical Data on Fuel, Seventh ed. John Wiley 8 Sons, Inc., (1977).
5. Singh, Jag J.; Davis, William T.; and Puster, Richard L.: Proposed Fast-Response Oxygen Monitoring and
Control System for the Langley 8Foot HighTemperature Tunnel. NASA TP2218 (1983).
6. Singh, Jag J.; and Puster, Richard L.: New Technique for Calibrating Hydrocarbon Gas Flowmeters. NASA TM
85792 (1984).
7. Singh, Jag J.; and Sprinkle, Danny R.: A New Technique for Measuring Gas Conversion Factors for
Hydrocarbon Mass Flowmeters. NASA TM-85676 (1983).
8. Sunner, Stig; and Mansson, Margaret, eds.: Experimental Chemical Thermodynamics. VolumeCombustion
Calorimetry. Pergamon Press (1979).
9. Weast, Robert C., ed.: CRC Handbook of Chemistry and Physics, 65th ed. CRC Press, Inc. (1985)
pp. D-275D-281.
AVAILABILITY OF NBS-TRACEABLE CALIBRATION
GAS STANDARDS FROM IGTPROGRAM UPDATE
Bruce H.Solka
Amir Attari
Institute ot Gas Technology
Chicago, IL 660616
ABSTRACT
The Institute ot Gas Technology has provided the American gas industry with natural gas standards ot
certitied calorific value and specific gravity since 1965. In August of 1984, a research program was
established at IGT to study the factors that may influence the stability ot natural gas calibration standards
during their preparation, storage, and use. The information obtained in the course ot this study is being used
to prepare a series ot calibration standards for natural gas measurements by gas chromatography and
calorimetry. This paper will review the history ot previous work and the cooperative research activities that
led to the preparation and availability of the new calibration standards that are traceable to the primary
standards from the National Bureau of Standards (NBS).
INTRODUCTION
Prior to conversion trom manufactured gas to natural gas, the standard practice of the American gas industry
was to calibrate its calorimeters with nydrogen. As natural gas gradually replaced manufactured gas in the
1940s and 1950s, the gas industry became concerned about the use of hydrogen as a calibration gas.
Although hydrogen has a calorific value reasonably close to that of the manutactured gas, it only has one
third the calorific value of natural gas.
This concern led to a cooperative program between the American Gas Association (A.G.A.) and the NBS
to study how accurately the Thomas recording gas calorimeter (made by Cutler-Hammer) could measure
gases of higher caloritic value. As a result of this study, it was concluded that the gas industry would require
a continuing source of calibration gases with calorific values near that of natural gas. In recognition of that
need a new program was initiated in 1957 by the A.G.A. under which the Washington Gas Light Company
would supply puritied natural gas, and NBS would provide the certification service.
213
In 1961, NBS suggested that the program De transferred elsewhere; IGT was selected to provide that
service. By 1965 the program was fully activated at IGT with the arrival of the first two cylinders of NBS
primary standards containing high purity (99.96 mole percent) methane; the balance consisted of ethane,
carbon dioxide, nitrogen and oxygen.
Today there are 3300 size 1A steel cylinders used in IGT service, with 100 to 150 cylinders added
annually. Since 1965, IGT has issued 8782 calorific value and 7983 specific gravity certificates.
The certified gas is prepared by purifying natural gas taken from a medium-pressure service main. The
purification is accomplished by passing the gas over activated charcoal to remove hydrocarbons heavier
than ethane, in order to improve gas stability. The processed gas, containing methane, ethane, nitrogen and
carbon dioxide, is then adjusted to the desired calorific value or specific gravity before compression to 2000
psi into evacuated cylinders. Quality control is maintained by periodic gas analysis, and by regenerating the
charcoal towers when propane breaks through.
During the certification procedure, each cylinder receives three test runs of 11/4 hour duration on three
Cutler-Hammer calorimeters that are calibrated daily against the NBS primary standards. The results of the
three determinations must agree to within 1 Btu/SCF betore they are certified for accuracy to 0.9 Btu/sCF
and shipped. Similarly, the specitic gravity readings obtained on our gravity balances must agree to within 0.
0005 units betore they are acceptable for certitication to 0.001 specific gravity unit. This degree of
precision and accuracy is achieved through a strict adherence to sound laboratory practices and regular
instrument maintenance and service. In addition, the certification laboratory has a constant temperature
regulation of 1.5F and a 100% exhaust system that removes any traces of combustible gases or vapors that
might otherwise cause errors in the calorimeter readings.
NEW PROGRAM
There is an ever increasing demand within the U.S. gas industry for improved accuracy in gas quality ana
gas quantity measurements. An important element of these measurements practices is the determination of
the caloritic value of natural gas which requires the best available instrumentation as well as reliable
standard gases to calibrate them.
The instruments used to measure the thermal content ot natural gas fall into two general categories:
Combustion calorimeters that directly monitor the thermal energy from the gas combustion.
Gas analyzers that first determine the gas composition, then calculate the calorific value from the
composition.
Both types of instruments require careful calibration with a gas of known calorific value or composition in
order to generate accurate results.
Standard gases have been readily available from IGT for the calibration of calorimeters and gravitometers
since 1965, but as the U.S. gas industry began to use gas chromatographs (GC) in their laboratories to
measure composition, they had to rely on calibration gases purchased from a variety of sources without
NBS traceability. Another change in measurement practices has been the need to measure fuel gases having
heating values far different than the nominal 1000 Btu/SCF.
Although reliable GC calibration gases were available from some vendors as a result of the
standardization activities of the Gas Processors Association (GPA), and the American Society for Testing
and Materials (ASTM) these gases lacked the NBS traceability that usually becomes an important
consideration in resolving difterences in the calculation of a purchased quantity ot energy at the custody
214 AVAILABILITY OF NBS-TRACEABLE CALIBRATION GAS STANDARDS FROM IGTPROGRAM UPDATE
transfer points. Clearly, a need existed within the gas industry for a series of new calibration gases with the
added confidence, consistency, and recognition that direct NBS traceability would have provided. IGT was
made aware ot this demand by an increasing number of inquiries from our current certified gas customers.
As a result ot these inquiries a questionnaire was mailed to 55 ot the present programs largest customers.
This questionnaire addressed their anticipated use of reference standard mixtures for gas chromatographic
analysis of natural gas. Of the 31 respondents, 80% were using GC at that time. satisfaction with available
standards was mixed. A clear majority desired NBS traceability of standards as well as calorimetric
verification of the heating value of the GC standard mixture.
The Gas Research Institute (GRI) also became aware ot industry interest in new reference standard
mixtures certified by an independent agency. To fulfill that need, in August of 1984 GRI initiated an
experimental program at IGT that has culminated in the availability ot a new 10-component standard gas for
GC calibration ana three new calorimeter standard gases for more precise calibration ot IGT calorimeters
used for gas certification in the range ot 800 to 1300 Btu/SCF.
The research conducted at IGT during this program nas provided information on the following
parameters that may influence the stability ot the calibration gases during storage and use.
1.
Selection of Gas Composition
A GC calibration gas is most useful when its composition approximates that of the test sample as closely as
possible. The survey referred to above gave respondents the opportunity to express their wishes regarding
the composition of a GC calibration standard. With this information as well as our own knowledge of the
typical composition ot pipeline-quality natural gas, numerous possible gas mixtures were considered as
candidates for this program. Given recent interest in the heavier ends of natural gases, careful consideration
was given to the advisability ot including hexane and heavier components in the standard.
Table 1 lists five mixtures that typify the composition ranges that were considered for a GC calibration
gas. A primary requisite for a usable standard is that its composition remain constant during the period ot its
use. While the presence ot heavy components may be desirable for calibration purposes, they increase the
possibility of composition changes caused by condensation or adsorption. In the northern climates, certified
gas cylinders may well be exposed to winter temperatures of30F duriny shipment or storage. Therefore,
we first calculated the SRK equation-ot-state dew points as a function of pressure for some 75 gas mixtures,
and based on that consideration, selected gas mixture D as our primary standard gas.
Table 2 lists the nominal composition ot the GC standard currently sold along with typical uncertainties
for each component. These uncertainties are based on the sum ot the uncertainty in the NBS certification
plus our instrument calibration and analysis of each cylinder.
Components/Sample 1 2 3 4 D
------------Mol %d -------------
i-pentane 1.00 0.15 0.15 0.15 0.10
n-pentane 1.00 0.15 0.15 0.15 0 .10
neo-pentane 0.05 0.10
n-Hexane 0.05 0.05 0.05 0.05
n-Heptane 0.01 0.02
n-Octane 0.01
Helium 0.46
Nitrogen 4.95 2.50 2.50 2.50 2.50
Carbon Dioxide 1.09 1.0 3.00 1.00 1.00
Propylene 0.02
Estimated dew point temperature, F at filling pressure of 300 psig * 24 12 3 12
*This gas is sold at a pressure of 100 psig for which the dew point is 24F.
2.
Certification process
Following the selection procedure, tour gas mixtures designated as A, B, C and D were commercially
prepared to IGT specifications, then analyzed by NBS for certification as primary calibration standards in this
program and returned to IGT.
Figure 1 diagrams the overall sequence of activities leading to delivery of IGT certified calibration
standards with NBS traceability.
GC Calibration Gas
We are currently shipping this standard with certifica-tion compositions determined in the following
manner.
Stock gas at the nominal composition shown in Table 2 is prepared in batches of adequate size to split on
a manifold into sets of six size N150 (or 15 size N60) aluminum cylinders. These sale cylinders are
prepared by a three-fold exhaustive cycle of evacuation and pressurization with nitrogen to purge any
residual gases.
Each sale cylinder is then analyzed by the following procedure. First, a daily system blank run is made to
verify that there are no GC system air leaks that will contribute to the oxygen/nitrogen values in the
certification analyses. Then three runs are made on the NBS certified primary to check the GC
calibration. Results are calculated by a relative response factor with normalization method. Response
factors for these three runs must agree with each other ana with those of preceding days to within
specified tolerances before the certification analysis can begin. The standard is again re-run midway
217
through the work day to verify that instrument response is not drifting during certification work.
Certified compositions for a given cylinder are determined by averaging a set of six results from
duplicate analyses conducted on three non-consecutive days. If coefficients of variance of results for
each of the 10 components are within allowable tolerances, that cylinders composition is considered
certitiabie.
Calculated calorific values and relative densities are provided with each certificate ot composition. it the
customer has ordered optional certification of caiorimetric value and/or measured relative density the
cylinder is transferred to the calorimetry laboratory for those determinations.
Similar efforts were made to obtain data on the linearity of response for the GC detector over a twenty-told
range of concentration (e.g., propane concentration range ot 0.25 to 5 mole percent) for each one of the 10
components present in the GC primary standard, except methane for which data for a range of 65 to 95 mole
percent had already been obtained. This information is essential for IGT it IMBS traceability is to be
maintained for the analysis ot natural gas samples with component concentrations that vary substantially
from those of the NBS primary standard.
Equipment Used
The particular set of equipment that has been assembled and dedicated to the GC portion of this program
consists of the following principal components:
218 AVAILABILITY OF NBS-TRACEABLE CALIBRATION GAS STANDARDS FROM IGTPROGRAM UPDATE
Sample Handling: vacuum manitold with validyne Model CD 223 Digital Manometer
The chromatography data station transmits results to an IBM PC computer via RS 232 communications for
the purpose ot data storage and evaluation.
The calorimetry certification program will continue to use the Cutler Hammer recording calorimeter that
has been the workhorse of the existing IGT program. This has been supplemented for the current program
expansion by the addition of a third calorimeter and construction ot an automated, six-port gas manifold
sampling system to permit unattended measurements on batches of five cylinders.
3.
Program validation
Container Materials
For convenience in shipping and handling, IGT felt aluminum cylinders would be the most attractive
choice ot the options available. To verity that storage stability would not be adversely affected, a storage
stability test was conducted.
A carbon steel and duplicate sets ot stainless steel and aluminum cylinders were filled with the standard
gas and analyzed monthly for seven months ana then bi-monthly to the present time. During this 14 month
period, no change has been observed in the concentrations ot any ot the 10 components in any of the five
cylinders. Aluminum cylinders are being used in this program for convenience and ease ot transport.
cylinders were returned resulted in values that were nearly identical in their limits of precision-variance to
the third decimal place of the analysis after we obtained the results betore shipping the cylinders.
Another conclusion that can be reached is that these six laboratories are doing natural gas analyses with a
fairly high degree of accuracy as can be judged by the inter-laboratory comparisons and standard deviations
of the set of data as a whole. within a single laboratory, the precision of day-to-day analysis is quite good.
Caretul inspection of the entire set reveals certain compounds that are giving problems to one laboratory or
another. These will be discussed in our final report to GRI on this program, but do serve to point out that a
routine crossreference or inter-laboratory quality assurance program may be of value to the gas industry.
Heating values were calculated from all of the results for Sample 1 and are included in Table 4. A range
of 4.5 Btu/SCF was observed which includes four values in the 1019 to 1020 Btu/SCF region which might
in fact meet the criteria for discarding as outliers when the final evaluation is done. This result as well as
those for the concentrations of the individual components, indicate that gas chromatography can be a valuable
analytical tool to the gas industry.
4.
Future Standards From IGT
At present the program is restricted to standards of the nominal composition as shown in Table 2. Within a
few months, as the program becomes more establisned, we will probably consider requests for other
concentrations of the listed components.
If interest is sufficiently high we may expand the component list to add higher carbon number
hydrocarbons or other light gases but this will require another set of program validation experiments betore
they could be ottered as another NBS-traceable standard.
75/NBS/PAP
220 AVAILABILITY OF NBS-TRACEABLE CALIBRATION GAS STANDARDS FROM IGTPROGRAM UPDATE
ABSTRACT
This paper deals with the effect that water vapor has on the heating value of natural gas. It outlines a brief
history of the evolution of energy measurement, its implications to the industry and its practical application
through examples of calculations of water vapor content on MMBtu calculations. This paper should
familiarize the reader with various methods and instruments used to determine water vapor content, and to
apply this information to practical use.
A Short History
The natural gas industry was founded on principles of volumetric calculation. In its infant years, the
determination of volume alone was sufficient for all practical purposes. Prior to the advent of even the
crudest mechanical calculators or electronic computers many of the standard gas flow calculation factors
were abbreviated or ignored.
As technology matured, and calculators and computers became more sophisticated, the gas flow
calculations became more precise and complete. Even so, the determination of HEATING VALUE was still
largely ignored.
In 1978, the Natural Gas Policy Act (NGPA) stipulated that producers and pipelines set the price of gas
according to the energy content of the gas. This began to get the industrys attention. It forced many
companies to at last deal with the issue. When FERC Order 93 was issued in July, 1980, it brought about a
complete change in the natural gas industry. Order 93 mandated that gas measurements must reflect the true
energy content of the gas. Rather than assume the Btu to be wet or dry, water saturation had to be
accurately assessed and compensated for. Suddenly, AS DELIVERED BTU became the industrys
favorite buzzword. And now, even though Order 93 has since been rescinded, we are still left with the
223
vestiges of its effect in the form of As Delivered contracts and settlements of overcharges made during
those years of pass-through costs.
A Little Chemistry
This brings us back to the question of, what is the effect of moisture content on the heating value of natural
gas. When fuels are burned, chemical energy is made available as heat. This energy may be used in
different ways such as power generation, heating, cooling, and cooking. The greater the heating value of a
gas, the less volume will be required to perform a specific task. Each pure gas has a definite and
characteristic heating value. Water contributes no heating value; therefore, when water is present in a
gaseous mixture as a vapor, it decreases the heating value and thus causes an increase in the volume of gas
required to perform a given task.
Water is always present in the production of natural gas in both the liquid and vapor phases. If water
liquid is present, molecules at the surface tend to escape into the space above. These molecules become
vapor and are free to mix with the other constituent gases in the stream. Ultimately, an equilibrium, or
steady state of balance is attained when the rate of escape and rate of return into solution are equal. When this
condition occurs, the gas is said to be saturated with water vapor. For any gas, this condition of balance or
saturation is directly proportional to the temperature (Boyles Law, T1=V1 as T2=V2) . The greater the
temperature of the carrier natural gas, the greater the volume of water that can be absorbed into solution.
Conversely, as the temperature of a gas begins to drop, the kinetic energy of the fluid decreases. As this
happens, the water vapor begins to condense and return to the liquid phase.
Calculations
Once an accurate actual water content has been determined, the practical effect that the moisture will have
on the heating value can be calculated by the following equation :
Btu Reduction Factor = 1(lbs H2O/MMSCF * 0.00002102)
Example 1:
During the monthly meter calibration at Acme Well No. 2, the technician determines by test the
water content was 37 Ibs H2O/MMSCF. The monthly spot sample determined the Btu factor at 14.73
224 THE EFFECT OF MOISTURE CONTENT ON NATURAL GAS HEATING VALUE
dry to be 1.030. The volume for that month was 16,000 MCF @ 14.73. Acmes contract dictates that a
water content of 7 lbs or less is considered dry.
377=30 lbs H2O/MMSCF
If the actual water content of the gas cannot be determined by measurement, it can be readily calculated
using the methods outlined in the IGT Research Bulletin 8, Equilibrium Moisture Content of Natural Gas
by R.F. Bukacek where :
For temperatures between 10F and 140F, the values of W are within 1 percent of the IGT tabular values.
Note that the values for A and B are given at 14.7 psia and 60F. If any pressure base other than this is used
the values for W must be corrected.
Example:
During the monthly meter calibration at Acme Well No. 3 the technician determined that the gas
was too wet to be tested by instrument. However, he did record that the temperature of the gas was 98
F and the well had 358 psia pressure. The monthly sample showed a Btu factor of 1.010 @ 15.025 dry.
The monthly volume was 9,050 MCF @ 15.025. Using the above calculations renders:
In practical application, the calculation of the Btu reduction factor can be facilitated by modern computers
and data processing systems by providing for the input of either the measured water vapor content or the
inputting of the temperature and pressure values with the subsequent Ibs H2O/ MMSCF calculation. These
values can then be picked up by the Gas Accounting Departments to calculate the MMBtu corrected for
water vapor at As Delivered conditions.
The effect of moisture content on heating value content is a serious consideration for all parties interested
in utilizing natural gas for whatever purpose. However, being aware of the diminuitive effects of water and
225
more importantly knowing how to quantify the effect of moisture content by using these calculations will
leave the user prepared to respond to any contingencies or to employ any methods needed to correct
deficiencies.
BIBLIOGRAPHY
Miller, R.W., Flow Measurement Engineering Handbook, 232 to 236. New York: McGraw-Hill Book Company,
1983.
Northwest Pipeline Corporation, Internal Company memo correlating IGT Bulletin 8 with Least Squares Curve Fit
equation.
Parent, J.D., Natural GasProduction and Transmission, 1023. Chicago, I.G.T. Home Study Course, 1952.
ON-LINE CHRGMATOGRAPHY
Jimmy L.Shafer
Product Development Engineer
UGC Industries
Shreveport, Louisiana
ABSTRACT
Rising natural gas prices have lead to an increasing awareness of the BTU content of natural gas. Custody
transfer is being based upon the heating value of the gas as well as the volume. Consequently, the on-line
gas chromatograpn or BTU analyzer is becoming an increasingly important instrument in the industry.
INTRODUCTION
Measuring the energy content of natural gas in an online fashion requires a self-contained instrument that is
programmable and rugged. Programmabi1ity allows the unit to run stand-alone collecting and analyzing
data unattended. Ruggedness allows the unit to be operated on location whether it be outdoors or in an air
conditioned control room.
The gas chromatograph is not only capable of meeting the needs for on-line applications but also
provides several additional features. Technological advancements in both micro-packed columns and
microprocessors have allowed the development of very powertul and flexible on-line gas chroma tographs.
BASIC CHROMATOGRAPHY
The basic chromatograph consists of several valves and micropacked columns configured in such a way
that when properly controlled will completely separate the constituents contained in a natural gas sample
(See Figure 1). Pure helium flows continuously through the columns. A sample of natural gas is injected
into the helium stream and is carried through the columns. The constituents in the natural gas sample have
an affinity for the material used in the micropacked columns. The degree of affinity is proportional to the
molecular weight of the constituent.
227
Figure 1
The constituents of the natural gas are carried through the columns at different rates, based upon their
affinity for the packing material, and emerge or elute from the end of the column at different times. As they
elute, the constituents are detected by means of a Thermal Conductivity Detector (TCD). A TCD is
basically a thermistor or wire which carries sufficent electrical current to cause self-heating . As helium
flows over the detector elements, heat is carried away by conduction. As the concentration of eluted gases
changes, more of less heat is carried away resulting in a detectable change in the temperature of the
element.
If the columns are sufficiently long, the constituents will be completely separated as the gas elutes from
the columns. To speed up the process, several different columns are used. The packing material in each
column is chosen for a particular capability and proper control of the configuration will maximize the
separation while minimizing the overall time.
The basic chromatograph has two modes of operation, inject and backflush. Inject is the condition when a
sample of gas of known volume is presented to the system. Backflush is the condition when a
rearrangement of columns has occurred for maximizing the process.
Reterring to Figure 1, solid lines indicate the column arrangement during an inject. A known volume of
natural gas sample is presented from the sample loop to the first column. This column is chosen for its
ability to hold the heavy constituents (C6, C7, C8), while passing the lighter constituents on to the second
column.
The second column will initiate the separation process of the lighter constituents during the first minute
after inject. At the end of a minute, the controller will rotate the valves to the backflush position as indicated
by the dashed lines in Figure 1. This will arrange the columns so that the first column is now ahead of the
second and is reversed. This will allow the heavy constituents to be backflushed onto the final column.
The heavy constituents, also called C6+, will remain unseparated and will be eluted onto the detector as one
component. Additional separation will occur in the other constituents throughout the process.
228 ON-LINE GAS CHROMATOGRAPHY
Figure 2
Figure 3
Finally, each constituent is eluted onto the detector for analysis. The time at which elution occurs allows
the microprocessor controller to indentify the constituent while the amplitude is used in calculating its MOL
%. Figure 2 shows a chromatogram taken from such an arrangement.
Calibration of the instrument occurs automatically. The frequency of calibration can be programmed by
the user. A certified calibration standard gas is used during the calibration cycle (See Figure 3). Response
factors are calculated based upon the area under the peaks taken during the chromatogram. Calibration
should be performed at least once every twenty-four hours for best performance.
The on-line gas chromatograph can be arranged in any of a number of systems (See Figure 4). As a
mocroprocessor-based instrument, communications and programmablity allow configuration into networks.
229
Figure 4
Remote operation can be achieved using modems and telephone lines. Data collection is handled by a
hardcopy printout, analog outputs, or a host computer communications link.
Figure 5
Figure 6
approximately fifteen minutes are required for a gas analysis cycle, only five minutes are needed for water
analysis.
A major disadvantage that the on-line gas chromatograph has is its inability to do continuous analysis.
Analysis occurs every fifteen minutes whereas the calorimeter is a continuous instrument. Second, the
chromatograph bases its analysis on theoretical calculations made from the measurement while the calorimeter
actually measures the BTU content by burning a sample of the gas. Room for error exists and great care
should be taken when specifying calibration gas for use with a gas chromatograph, expecially with respect
to the C6+ composition.
231
SUMMARY
The on-line gas chromatograph has become a viable tool in the industry for measuring BTU content of
natural gas. It compares favorably to the industry standard calorimeter in tracking BTU changes. A very
rugged device, the on-line gas chromatograph boasts a repeatability of +1 BTU/SCF out of 1000.
RELIABILITY OF COMPONENT ANALYSIS BY GAS
CHROMATOGRAPH FOR CALCULATION OF HEATING
VALUE
R.M.Batubara and K.Tatang
Laboratory Division
P.T.Badak NGL Co.
BontangKalimantan Timur
Indonesia
ABSTRACT
The determination of natural gas composition by gas chromatography using reduced pressure techniques
enables the gas analyst, by close monitoring of sample loop pressures, to ensure that very accurately
reproducible sample volumes are injected into the analysis system. This in turn, leads to greater precision in
the derivation of response factors from pure gases, and the subsequent analyses of reference standard gas
and sample gas compositions which is essential if reliability is to be maintained in calculating natural gas
heating values. Using these techniques, response factor repeatabilities well below 1% have been achieved.
The selection of multi-column analytical system in conjunction with reduced pressure sampling technique
has afforded analysts greater resolution and reproducibility well within GPA tolerance limits. This degree of
reliability is demonstrated by the results of biennial inter laboratory test programs in which error of heating
value from compositional calculation has been reduced to 0.1% . Accuracy in determination of LNG heating
values is a major economic incentive, being the most important factor in LNG custody transfer calculation,
and in presenting this paper the manner in which highly reliable data are obtained for this purpose is set out
in detail.
INTRODUCTION
Precise gas analysis technique is essential in order to obtain compositional analysis data for the reliable
determination of natural gas heating values. Since 1977, laboratories in Indonesia and Japan serving the
LNG export and import trade between these countries have co-operated to develope analytical procedures,
based on GPA Standard 2261, that provide the required level of reliability. This paper sets out to show that
stringent adherence to technique together with carefull selection of equipment and reference materials can
achieve the level of reliability required to accurately calculate LNG heating value.
NATURAL GAS CORRELATION TEST RESULT BETWEEN 233
Gas Chromatography
Any gas chromatography by a reputable manufacturer, fitted with a thermal conductivity detector and suited
to multi column operation, may be used.
Detector
The detector shall be a thermal conductivity type with high sensitivity and stability. The selection of detector
temperature depends on sample composition, but temperatures of 1050 C above analysis column
temperature have been found to provide adequate sensitivity. Regular checks on detector linearity are
essential in order to detect signs of filament ageing. The detector should be brought up to temperature and
the current switched on several hours before analysis runs to ensure stability. Periodic cleaning, once every
six months with suitable non corrosive solvent is recommended to further ensure detector stability.
Columns
The chosen column for the separation of hydrocarbon components C3 and heavier is 1/8"5 ft packed with
30% Silicone DC 200 on 80/100 mesh acid washed Chromosorb P. CO2 and C2 are separated on 1/8"6 ft
column packed with 80/100 mesh Porapak Q. An adsorption column, 1/8"10 ft, packed with 45/60 mesh
13 X Molecular Sieve.
These columns are set in a series by-pass flow path with switching valves fitted with flow restrictors
adjusted as required to maintain a stable base line.
Column Temperature Control. Calibration and analysis runs are iso thermal at 70 C 0.3 C.
Column Conditioning. The columns are conditioned for 24 hours prior to being installed in the
chromatograph. This conditioning is done in seperate ovens set aside for this purpose, the DC 200 and
Porapak Q columns are conditioned at 225 C with a carrier flow of 30 ml per minute. The Molecular Sieve
column is conditioned at 350 C with a carrier flow of 50 ml per minute.
Recording Instrument
A strip chart recorder, or an electronic integrator with print-out facility may be used to display the peaks for
the seperated components.
Manometer
An absolute pressure manometer for sample pressure measurement with vernier that can accurately read to
0.1 mm Hg, measurement of the injected sample. U-tube style manometers are not recommended for this
purpose.
234 RELIABILITY OF COMPONENT ANALYSIS BY GAS CHROMATOGRAPH FOR CALCULATION OF HEATING VALUE
Vacuum Pump
A vacuum pump with a capability of less than 1 mm Hg absolute.
Drier
A drier consisting of a 4 inch length of 1/2 inch stainless steel tubing, packed with 4060 mesh Calcium
Chloride, with both ends plugged with glass wool is fitted to the sample inlet system.
Carrier Gas
99.99% Helium, filtered through a Molecular Sieve moisture trap is metered through two flow controllers to
provide a flow rate of ml per minute through analytical and reference columns. Flow restrictors fitted to the
switching valves are adjusted to provide a stable baseline with columns in series flow or by-passed.
ANALYSIS DESCRIPTION
The basic method for natural gas analysis used is GPA Standard 2261. Components to be determined in a
representative natural gas sample are physically separated by gas chromatography and compared to the
known composition of a standardized reference gas which is determined under identical operating
conditions.
To obtain optimum accuracy of compositional analysis, the following steps should be executed :
NATURAL GAS CORRELATION TEST RESULT BETWEEN 235
It is not recommended to use the manufacturers composition analysis supplied with the reference gas
mixture. Therefore, the reference gas composition has to be determined using the same gas chromatograph
as used to analyze the natural gas sample.
If significant changes of response factors are subsequently observed, it will be necessary to re-check the
linearity of pure gas response factors. If several response factor changes are detected, re-determined of
referencegas composition shall be done.
The quantification of calibration and sample analysis can be derived as follows:
The purity of pure gas requires to be checked prior to use for response factor determination or prior to
linearity check of pure component response factors. Purity of pure gas is checked by consecutive analysis
runs of each pure gas. The component area divided by the sum of peak areas recorded with each
component, will be used as a measure of the purity of component.
Using response factors derived from pure gases, determine the composition of the reference gas by
making several analysis runs at diffrent partial pressures. The peak areas obtained in these runs are
converted to unnormalized mol percent (100 1%) using the above equation.
With the same equation, the natural gas sample composition can be determined from peak area of each
component recorded following two or more consecutive analysis runs of the sample gas directly after the
reference gas calibration runs for obtaining response factors.
If the reference gas does not contain C6+, the concentration of hexanes plus in a natural gas sample can be
calculated as follows:
It is recommended to monitor the stability of the response factors derived in each calibration run of
reference standard gas prior to analyze of sample gas. If response factors vary by more than 1%,
recalibration and determination of reference gas composition should be considered .
The other dominant factors of analysis, analysis run time sequence and valve switching configuration
will be discussed in the next paragraphs.
236 RELIABILITY OF COMPONENT ANALYSIS BY GAS CHROMATOGRAPH FOR CALCULATION OF HEATING VALUE
30.00 stop
Figure 2. CHROMATOGRAM OBTAINED FROM INDONESIA BADAK LNG PLANT NATURAL GAS FEED.
COLUMN 1: SILICONE DC 200 COLUM 2: PORAPAK Q, COLMN 3: MOLECULAR SIEVE 13 X.
Purity of pure gas
This comprehensive calibration procedure includes the purity check of pure gases. This should be checked
by actual analysis on the gas chromatograph used. It is not recommended that the manufacturers label of
pure gas concentration attached on each cylinder be used.
238 RELIABILITY OF COMPONENT ANALYSIS BY GAS CHROMATOGRAPH FOR CALCULATION OF HEATING VALUE
The method of determination of pure gas concentration is to calculate the area of each peak by the
following equation:
M = purity of component.
i = component.
Ai = peak area of component.
Pure gas purity shall be 99.0 % or higher except for oxygen and nitrogen. Dry air can be used directly for
oxygen/nitrogen with the composition of 21.87% for oxygen and 78.08% for nitrogen.
Repeatability Analysis results in mol percent shall differ by less than 1% purity as obtained from several
consecutive analysis runs.
A reasonable period for linearity checks using pure components is once every 23 months or if any
significant changes in the response factor are observed.
NATURAL GAS CORRELATION TEST RESULT BETWEEN 241
Repeatability and Error.The error calculated for each unnormalized component mol % shall be less than 1%
or the difference between peak heights for the smallest component within 1 mm.
The total composition before normalization must be 100 1%. The technique is to make two or more
runs which have a repeatability of 100 1%, then average the un-normalized totals, then normalize the
average for the final result.
If un-normalized total is not within 100 1%, new response factors need to be re-checked.
Two or more analysis runs are made for both the reference standard gas and the sample gas. These runs are
made consecutively to ensure that the component response factors are derived from reference standard gas
analysis runs made under identical conditions to the sample gas runs.
There are two steps in determination of sample composition. The first being the derivation of response
factors from a reference standard gas of known composition, followed by the analysis of the sample gas.
Procedure. Inject a sample of reference standard gas of known composition at absolute pressure of 700
mm Hg. Repeat at least once, and calculate response factors for each component in the reference standard
gas. Error shall be less than 1% for each component response factor. In the same operating condition inject
the sample gas at absolute pressure of 700 mm Hg, repeat at least once and obtain peak areas for each
component. In order to obtain the unnormalized composition of the sample gas, multiply the peak areas of
each component by the appropriate response factor derived from the reference standard gas by using the
above equation.
Error calculated for each unnormalized component mol % shall be less than 1% or for the smallest
component the difference between peak heights shall be less than 1 mm. The sum of all unnormalized
component mol % shall be 100 1%. The unnormalized component mol % are then averaged and the final
sample composition is obtained by normalizing to total of 100%. Attached table 4 is an example of
calculation method for natural gas composition analysis.
Component Molar Fraction (Xi) Value @ 60F BTU/cu.ft (Hi) (XiHi) in BTU/SCF
C2H6 . 0 5 9 5 1769.7 1 0 5 . 3
C3H8 . 0 3 6 1 2516.1 9 0 . 8
iC4H10 . 0 0 7 0 3251.9 2 2 . 8
nC4H10 . 0 0 8 1 3262.3 2 6 . 4
iC5H12 . 0 0 0 5 4000.9 2 . 0
nC5H12 . 4008.9 .
nC6H14 . 4755.9 .
N2 . 0 0 0 4 0 .
O2 . 0 .
CO2 . 0 .
Total 1 . 0 0 0 0 1 1 4 4 . 6
JAPAN LABORATORIES
mol % CHITA CHIT SENB HIMEJ HIMEJ TOBA P.T.AR P.T.BA AVER Error TOLER
COMP CHUB A OKU I I TA UN DAK AGE 1 ANCE
ONEN U TOHO OSAK OSAK KANS KITAK ALLO
T ELECT GAS A GAS A GAS AI YUSH WED
RIC ELECT U LNG BY
RIC ELECT GPA
RIC STAN
DARD
max 2/1
min2 100%
CH4 86.57 86.53 86.43 86.41 86.55 86.34 86.47 0.23 0.27 0.30
C2H6 8.41 8.32 8.29 8.39 8.29 8.40 8.35 0.12 1.44 0.10
CO2
C3H8 3.69 3.80 3.86 3.86 3.82 3.88 3.82 0.19 4.97 0.05
iC4H10 0.62 0.63 0.69 0.63 0.63 0.65 0.64 0.07 10.94 0.03
nC4H10 0.63 0.64 0.65 0.64 0.63 0.65 0.64 0.02 3/13 0.03
iC5H12 0.05 0.05 0.05 0.04 0.05 0.05 0.05 0.01 20.00 0.03
nC5H12 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0 0.03
Total 100.00 100.00 100.00 100.00 100.00 100.00 100.00
HHV 1159.2 1160.6 1162.7 1161.7 1162.9 1161.9 1161.3 3.7 0.3
mol % CHTT CHITA SENB HIMEJ HIMEJ TOBA P.T.AR P.T.BA AVER Error TOLER
COMP TA TOHO OKU I I TA UN DAK AGE 1 ANCE
ONENT CHUB GAS OSAK OSAK KANS KITAK ALLO
U A GAS A GAS AI YUSH WED
ELECT ELECT U LNG BY
RIC RIC CPA
STAN
DARD
max 2/
min 2 1100
%
nC5H12 0.00 0.00 0.00 0.00 0.00 0.00 0.03
Total 100.0 100.0 100.0 100.0 100.0 100.0 100.0
HHV 1150.8 1152.6 1151.5 1151.7 1153.9 1151.2 1151.9 3.1 0.3
ACKNOWLEGMENT
The authors appreciate the support and encouragement of Sukardji Wibowo, Hadi Daryono and Join
Management Group of JapanIndonesia LNG Project for providing LNG Buyer & Seller inter laboratories
correlation test data.
REFERENCES
1. Annual book of ASTM standards, D 194581, Analysis of natural gas by Gas Chromatography. American
Society for Testing and Materials Philladelphia, USA.
NATURAL GAS CORRELATION TEST RESULT BETWEEN 255
2. GPA publication 214585, standard table of physical constants of Paraffin Hydrocarbon and other components of
Natural Gas.
3. GPA standard 226172, method of analysis for Natural Gas and Similar gaseous mixtures by Gas
Chromatography. Gas Processors Association Tulsa Oklahoma.
4. GPA standard 217276, method for calculation of gross heating value, specific gravity, and compressibility of
Natural Gas mixtures from compositional analysis. Gas Process Association Tulsa Oklahoma.
5. Hewlett Packard Gas Chromatograph Instrument Manual Vol.15,HP 5880 A, April 1984.
6. Hewlett Packard 5880 A Gas Chromatograph Data Sheet Natural Gas Configuration, 1979, August.
7. IndonesiaJapan LNG Project analysis sampling system at each terminal, data sheet , JapanIndonesia LNG
Co. LTD. 1985, August.
8. Ludwig Huber, Rapid and Simple Analysis of Natural Gas by G.C. J. Chrom. Sc.-,Vol. 21, 1983, November.
ENRICHED SYNTHETIC NATURAL GAS
MEASUREMENT
Thomas A.Clark
Production Manager
ENERCO, INC.
Honolulu, Hawaii 96842
ABSTRACT
GASCO, INC., formerly the HONOLULU GAS COMPANY, is unique in that its entire gas distribution
system is supplied by manufactured gas. GASCO bills its customers by the THERM, which normally
requires two measurements: a volumetric measurement and a heating value measurement. Due to variations
in the gas composition and heating values resulting from the manufacturing process, determination of
Therms becomes more complex. In order to achieve accuracy, the SNG measurement system has grown
to include the following components:
Information from the first six components are fed daily into the computer, which uses the information to
calculate the quantity of gas produced. The calculated production is then compared to the THEORETICAL
PRODUCTION, computed by using a mass balance equation for the plant as a check.
To complete the measurement data, the degree of saturation with water vapor must be determined as
GASCO is permitted to sell its gas saturated at the temperature at the customers meter. Thus, in order for
GASCO to measure its gas production, it requires a complex system of measurements, analyses, and
calculations.
257
BACKGROUND
The Hawaiian Islands are geologically quite young, thus there are no fossil fuels available. This unique fact
of nature has put Hawaii ahead of the rest of the world by subjecting it to numerous ENERGY CRISES
throughout time.
When Captain Cook first landed in Hawaii in 1778, Hawaiians were using RENEWABLE SOURCES OF
ENERGY, firewood and kukui nut oil. As the population grew, the supply of these items became
insufficient and the first ENERGY CRISIS was faced. As the whaling fleets came to Hawaii, people began
using whale oil. Again, as the world demand for this energy form increased, the price rose from 43 per
gallon in 1823 to $2.55 per gallon in 1866; thus, Hawaii faced another ENERGY CRISIS. With the
discovery of petroleum around 1860, the world as well as Hawaii began their dependence on fossil fuels.
In 1904, the Honolulu Gas Company began building its first oil-fired gas plant, which further emphasized
Hawaiis dependence on imported fossil fuel.
Due to Hawaiis unique situation, all forms of energy have been expensive. The major escalation in the
price of natural gas and other related forms of energy in the 1970s which generated the massive interest in
the precision and accuracy of measurement in the gas industry has been a fact of life for us for decades, and
the demands for accurate metering have always been foremost in the policies of The Gas Company.
INTRODUCTION
In 1974 GASCO, Inc., formerly the Honolulu Gas Company, built and put into operation a Lurgi Process
Synthetic Natural Gas Plant. In a single step, GASCO made the transition from the Stone Age to the
Twentieth Century without having the benefit of the growth stages in between. When the dust had settled
258 ENRICHED SYNTHETIC NATURAL GAS MEASUREMENT
Figure 1.
and our production reports were compiled for the first full month of operation, the corporate profits were
disastrous while the unaccounted for gas soared. Questions from upper management began to pour in on
the accuracy of our meters. In addition, the SNG Plant was built in a Foreign Trade Zone adjacent to our
sister refinery, so we had to not only satisfy Company personnel on the accuracy of our meters but also the
U.S. Customs and Foreign Trade Zone officials. The quest for both accurate and precise measurement
was about to begin. What follows is how we developed what we felt is within reason an accurate and precise
metering system. There is no attempt to make a judgment as to the accuracy of the standards, or the
deficiencies in the technology used, only how using off-the-shelf items a system can be built to satisfy your
metering needs.
SYSTEM DEVELOPMENT
The interest in our metering accuracy can better be understood if you look at our gas rates. In 1974, they
were $7 per million BTU, or 70 per therm, at the residential level and $5.30 per million BTU, or 53 per
therm, at the commercial level. In addition, the SNG Plant was incorporated as a separate entity, selling all
of its output to GASCO for distribution to its customers; thus, unaccounted for gas became a GASCO
problem but was very much dependent on the accuracy of our meter. It seemed easier at the time to say
The SNG plants meter was inaccurate than to admit there were leaks in the distribution system.
In the beginning, our system was fairly simple (or so we thought). SNG (see Figure 3 for analysis) was
produced at a constant rate with a consistent quality and enriched with LPG (utilizing Liquified Petroleum
Gas C-2C-5). The mixture was measured with a gas turbine meter and sent to the transmission line for
GASCO (Figure 4).
THE PROBLEMS
As the system was examined for possible errors, many actual and potential problems were uncovered.
259
Figure 2.
1. The turbine meter had a mechanical correction system for temperature and pressure compensation. This
system was subject to excessive wear and resultant inaccuracies.
2. The turbine blades in the meter cartridge had a short life expectancy.
3. The turbine bearings had a relatively short life.
4. The pressure at the meter was not constant.
5. Supercompressibi1ity was not fully understood. It was determined that SNG is significantly different
from natural gas due to the hydrogen and carbon dioxide content , as well as the higher hydrocarbons,
and that using data developed for natural gas was inaccurate.
The availability of Enrichment LPG was dependent on the type of crude oil available to the refinery
and, thus, the enrichment quality would vary, resulting in the need to vary the CO-2 content to maintain
a constant Wobbe Index (Note: SNG, as produced, contains approximately 20% carbon dioxide, which
is removed in a hot potassium carbonate system. Part of the CO-2 is left in the gas to control the Wobbe
Index.) Thus, the change in composition changed the Supercompressibi1ity.
6. The composition of the LPG varied also with the type of crude oil. Thus, when the LPG was high in
C-4s and C-5s, there was a question as to whether the LPG was fully vaporized when flashed into the
SNG line.
If the LPG was not fully vaporized, what effect did the droplets have on the turbine meter accuracy,
blades, and bearings?
7. Factory calibration of the turbine meter was not reliable and no local means of calibration was
available.
8. Using the orifice meters for a check was unreliable because of changing gas composition due to
variable enrichment which changed the gas density.
9. If the LPG was not being fully vaporized, was the the gas stream going to the Calorimeter
representative of the gas being sold?
10. Was the Dew Point being recorded a true Dew Point, or a hydrocarbon Dew Point?
260 ENRICHED SYNTHETIC NATURAL GAS MEASUREMENT
Major Components
Hydrogen.. 10.0% 2.0%
Methane.. 77.0% 3.0%
Carbon Dioxide.. 5.0% 2.0%
Enrich ment Gas..... 8.0% 1.5%
Average BTU ..... 1 ,050 10
Average Specific Gravity..... 0.675 .015
Figure 3. SNG Analysis
11. Was our 1960s vintage gas chromatograph giving us the degree of accuracy we needed in our gas
analyses?
12. Was the meter really a problem? The primary reasons for suspicion were: the calculated plant
efficiency (with no operating history, this figure was questionable) and the calculated
UNACCOUNTED FOR GAS, the accuracy of which was also questionable.
THE SOLUTIONS
Step 1. As previously mentioned, GASCO sells its gas by the therm which requires a minimum of two
measurements, a volumetric measurement and a heating value measurement. The first and simplest thing to
check was the accuracy of the Calorimeter, a relatively simple matter, and then to determine if the
Calorimeter was reading a representative gas sample regardless of the injection rate of enriching LPG. A test
was run using the SNG Plant Calorimeter and the Calorimeter at the old manufactured gas plant
approximately 22 miles away. The results showed that the BTU measurements were identical when the time
delay was accounted for. We thus assumed the SNG Plant Calorimeter was measuring a representative
sample.
The next step was to resolve the problems, or potential problems, identified earlier. The first logical step
was to put a more sophisticated meter in series with the first meter. The new meter had its own flow
computer and electronic compensation for temperature and pressure. Automatic compensation for changing
supercompressibility was not incorporated because it was known that SNG could not be made to fit the
correction curves designed for natural gas. Results: With the plant operating at constant flow rate,
temperature, and pressure, using two new factory calibrated cartridges, the meters read 3% apart! I will not
go into attempts to resolve these discrepancies with the manufacturers .
261
The next step was to develop a new standard of comparison for judging meter accuracy. The SNG Plant
has a theoretical mass balance equation that reduces to the following:
eq. (1)
Since the plant feed analysis is usually given in weight fractions (i.e., weight percent Carbon and weight
percent Hydrogen) all we needed to know was the weight of the feed plus its C/H ratio and an analysis of
the gas produced to calculate the plant output.
The complete plant mass balance was set up on the computer. A test was run under controlled conditions,
inputting all of the required data and the meter checked to within 0.4% of the mass balance. We now had a
method of determining the accuracy of our meter under controlled conditions; however, the C/H ratio of the
feed had to be determined in a mainland laboratory and the gas analysis using our old GCs was very time
consuming.
We still had to determine the cause of the mechanical problems with the meter. A thorough analysis of
the problem led to a simple solution that also eventually solved some of the other problems. A vaporizer
was added to the enrichment LPG and the injection point was moved down stream of the meter. This
addition solved not only the mechanical problems with the meters but also reduced the variation in gas
composition seen by the meter. The Dew Point was now read before the addition of enrichment, eliminating
the question of hydrocarbon Dew Points.
Using this method, however, we became dependent on a liquid turbine meter to determine the quantity of
the liquid LPG and a chromatographic analysis to determine the composition from which other physical
properties could be calculated.
We now had the beginnings of a system we could feel comfortable with; however, the system was far
from acceptable. Our goal was to develop a system that was both accurate and precise, with the accuracy
and precision verifiable on a daily basis. To accomplish this, we would need the following:
1. A new computer
2. Two on-line computer- or micro-processor-controlled gas chromatographs
3. An automatic sampling system
4. Data handling system for GC information
5. Software
6. Additional meters on the liquid streams
7. Automatic system checks
8. Additional information; i.e., specific gravity determi nati ons
A team consisting of design engineers, chemists, computer programmers, and instrument engineers was put
together. They designed and built the following system:
The plant mass balance was included in a daily report. This compares the theoretical plant output to the
metered plant output (Figure 5). For this to be meaningful, however, all of the inputs had to be accurate and
timely. To accomplish this, two new automated Perkin-El mer Gas Chromatographs were purchased and
installed, one for gas streams and one for liquid streams. The manpower and time required to generate all of
the required information, however, was prohibitive for a small lab staff and while the GCs had their own
microprocessor, it was insufficient to handle all of the data. We, therefore, purchased an additional IBM PC
to operate the system which also included an automatic sampling and sample conditioning system. With this
system in place, we could now not only automatically analyze all of the plant input and output streams
(Figure 6) but also use a daily calculated supercompressibi1ity factor to adjust the average factor used in the
262 ENRICHED SYNTHETIC NATURAL GAS MEASUREMENT
SNG meter flow computer. The overall plant efficiency is also calculated which is another check on both
the process and the metering (Figure 7).
To eliminate questions of accuracy of liquid meter data and specific gravity data (used to generate the
inputs for the mass balance) liquid mass meters were installed as a check. The problem is, however, when
you have two meters in service and they generate conflicting data, which is correct? To solve this problem,
integrators and totalizers were added to the orifice meters as a check on the other meters. When at least two
out of the three read the same, we assume they are correct. This limits the amount of time we have to spend
calibrating meters.
And, finally, the specific gravities of the gas streams were determined by Ranarex Gravitometers and the
liquid streams by a hydrometer. This data is then compared with the analytical data generated by the
laboratory. By comparing the calculated BTU and specific gravity values to the measured values, we can
immediately spot errors in either measurements.
Since all of the above information is available in the computer, we print it out on a daily basis on a
Quality Control Report. This report is then reviewed by the Instrument Engineer (in charge of metering), the
Plant Chemist (in charge of analyses) and the Technical Coordinator (in charge of software) to resolve
whether discrepancies are a result of measurement errors, analytical error, or data input error (Figure 8).
A schematic of the present system (Figure 9) represents an investment of over $500,000 and two- to
three-man years of development. All of the components of the system are calibrated on a regular basis to
ensure accuracy.
The plant metering system computes the total number of therms of gas saturated at 60F and 30 inches
of mercury sold to GASCO, INC., our distribution subsidiary. GASCO, however, is permitted to sell gas
saturated with water at the temperature at the customers meter. Since the actual
CONCLUSION
What I have presented is the solution to a unique metering problem, where in order to measure an
ENRICHED SYNTHETIC NATURAL GAS stream, requires (in addition to a volumetric and heating value
measurement) two gas chromatographic analyses to calculate the supercompressibi1ity of the raw SNG and
the heating value of the enriching LPG, one liquid volumetric analysis, and a specific gravity measurement
263
ABSTRACT
This paper discusses the development and implementation of an automated gas analysis system. The major
advantage of the system is its capability to process twice as many gas samples as before. Also,
improvements were noted in accuracy and repeatability as compared to the results derived from 3 devices
(calorimeter, gravitometer, and gas chromatograph). Substantial savings in the order of $170,000.00 per year
were realized in the areas of manpower and operating cost reductions as a result of implementation of the
new system.
INTRODUCTION
NOVA, AN ALBERTA CORPORATION owns and operates a natural gas transmission system in the
Province of Alberta and handles more than 75 percent of the Canadian gas sold in North America. As of
December 31, 1985, NOVAs Alberta Gas Transmission Division recorded receipts of 2.25 trillion cubic
feet with an average of 6.2 billion cubic feet being moved per day. NOVAs system consists of 756 receipt
and major delivery metering points connected by 8,559 miles of pipeline.
Prior to December 1983, NOVA operated two quality control laboratories, with each laboratory analyzing
approximately 600 gas samples per month. All 600 samples were analyzed on the calorimeter and
gravitometer with only a portion being analyzed on the gas chromatographs to determine hydrocarbon and
inert components. This was a very time consuming function as the samples had to be run on the calorimeter
for 45 minutes in order to get reliable results. Samples analyzed on the gas chromatographs had to be
manually injected thus limiting the number analyzed per 8 hour working day. The results obtained from the
calorimeter, gravitometer, and gas chromatographs were used for custody transfer billing calculations.
270 AUTOMATED GAS ANALYSIS SYSTEM
A concept using calculated gravity and heating value from the gas analysis for custody transfer billing
was presented to Consumer and Corporate Affairs (Canadas regulatory agency) for approval in 1979.
NOVA CORPORATION began development and in late 1983, implemented an automated gas analysis
system capable of analyzing all samples on the gas chromatographs. This innovative concept has resulted in
many tangible benefits and savings. The two laboratories were amalgamated into one centrally located
facility which now analyzes 1450 samples per month.
CONFIGURATION
The present configuration used by NOVA consists of two stream selector valves to which thirty-one gas
samples are connected. These samples are regulated to approximately 210 kPa (30 psig) and are systematically
purged through either of two computer controlled 16 port stream selector valves. The stream selector valves
are air actuated and are controlled by two three-way solenoids. Each sample is further regulated to 105 kPa
(15 psig) before it passes through a three-way solenoid controlled valve. This solenoid valve has the
capability of directing the gas to the differential pressure switch or to an outside vent. When the three-way
solenoid valve is turned to vent, two things occur:
The differential pressure switch is set so that when atmospheric pressure is sensed, it completes the circuit
connecting it to the remote start on the Analog to Digital Converter (A/D) and injects the gas sample. The
next component is a two-way solenoid controlled valve that is used in controlling the purging time of low
pressure samples and also for shutting down the system on completion of the sample rotation. (See
automated sampling configuration diagram).
CAPABILITY
This system is capable of analyzing 57 samples per standard work day compared to a maximum of 25 using
the manual injection technique. At the beginning of each day a technician runs a calibration standard to
verify the accuracy of the gas chromatograph. At the same time, the automated system is loaded with 26 gas
samples which is the maximum number that can be analyzed by the end of the regular working day. Before
the end of the regular working day, the automated system is again loaded with a new batch of 31 gas
samples. During the day the technician processes the previous batch and that days analysis information
while the gas chromatographs are automatically analyzing a new batch of samples. This system could be
further expanded by the addition of another 16 port stream selector valve which would further increase its
capability to 84 samples per 24 hour period.
BENEFITS
Repeatability
Discussion of Results. The repeatability of heating values derived using a gas chromatograph has resulted in
a lowering of the standard deviation experienced by over 60% when compared to the calorimeters heating
value.
271
Tests conducted over an extended period of time (four months) have demonstrated that the standard
deviation in the calculations for heating value derived from compositional analysis of a primary standard
272 AUTOMATED GAS ANALYSIS SYSTEM
For this same time period the heating value derived from the laboratory calorimeter had a standard deviation
of 0.0285 MJ/m3 (0.8 BTU/cf).
This calorimeter was recalibrated whenever it was off by more than 0.06 MJ/m3 (1.6 BTU/cf) from the
certified value of the Standard Gas.
Accuracy
Calculations of total energy for orifice metering facilities using the results from two devices (gravitometer
and calorimeter) can result in a worst case error of approximately 0.4%. However, the principle of the gas
chromatograph operation places a direct correlation between relative density and heating value, thus
reducing this error to 0.01%.
It is prudent to use a well maintained gas chromatograph system as a single source for these values since
the total energy measured is multipled by some monetary value per GJ (MMBTU). (See Appendix A).
the use of another gas chromatograph that analyzes for helium using argon as a carrier gas. (See
appendix B).
Timeliness of Results
Gas Chromatograph analysis results are available in 17 minutes after injection compared to 45 minutes for
the calorimeter.
1. Daily analysis of a secondary standard and agreement of results within the limits of repeatability stated
in ASTM D1945.
2. Daily plottings of values for relative density, heating value, and some of the mole fraction components.
3. Verification using a Primary Standard whenever the secondary standard varies by more than 0.04 MJ/m
(1.1 BTU/cf). Recalibration occurs when the heating value is greater than 0.03 MJ/m3. (0.8 BTU/cf).
4. Monitoring of gas samples from new stations on a gravitometer and calorimeter to ensure there is no
component present (in any appreciable amount) for which the gas chromatograph is not calibrated.
5. Monitor stations with hexanes plus concentrations greater than 0.0014 mole fraction. Reason: If this
amount of hexanes were actually octanes, the calculated heating value would be lower than the actual
value by 0.08 MJ/m3 (2.1 BTU/cf)
ECONOMICS
NOVA CORPORATION has realized substantial savings in operating costs as a result of the automated gas
chromatograph. The cost of materials for a 16 sample automated system was approximately $5,000.00 and
$10,000.00 for a 31 sample automated system. The need to expand or upgrade an air conditioned calorimeter
room to meet the increasing number of samples analyzed was eliminated. Also, the alternative of purchasing
another device capable of measuring heating value was no longer required. A reduction of approximately $8,
000.00 per year in calorimeter maintenance costs resulted with no appreciable increase in the gas
chromatograph maintenance costs. Substantial savings were realized as NOVA was able to combine the
operation of two laboratories. A net decrease in manpower costs of approximately $170,000.00 per year was
realized. As well, we were able to reduce the operating expenses of maintaining two laboratories with
duplicate equipment.
CONCLUSION
The main advantages of an automated gas chromatograph system are:
1. Increased capacity.
2. Increase in repeatability over previous conventional methods used.
3. Increase in accuracy.
4. Identification of some potential problem areas that can affect total heat energy.
274 AUTOMATED GAS ANALYSIS SYSTEM
APPENDIX A
Example
Actual values for the Gas Standard were
Relative Density (R.D.)0.560
Heating Value37.80 MJ/m3 (997.7 BTU/cf)
Results from the various instrumentation are acceptable with the following tolerances:
Gas Chromatograph
Relative Density0.560 0.001
Heating value 37.80 MJ/m3 0.02
(997.7 BTU/cf 0.8)
Calorimeter
Heating value37.80 MJ/m3 0.08
(997.7 BTU/cf 2.1)
Gravitometer
Relative Density 0.560 0.002
Energy Calculation = Heating Value Corrected Volume
Imperial System
BTU/cf Corrected Volume (MCF) = MMBTU
Metric System
TABLE 1
Largest positive error occurs when
Gas Chromatograph Calorimeter & Gravitometer
0.559 Relative Density (R.D.) 0.558
37.77 Heating Value (MJ/m3) 37.88
50.517 Calculated Ki 50.710
+0.01 % Error +0.39
0.561 Relative Density (R.D.) 0.562
37.83 Heating Value (MJ/m3) 37.72
275
The Same calculation could aslo be used for calculating k and ki in the Imperial System of Measurement by
substituting BTU/cf for MJ/m3.
APPENDIX B
ExamplesCalculation with and without helium
ABSTRACT
Apparatus described uses exponential dilution method to determine range of linear measurement for BTU
analysis. Every component measured by the gas chromatograph can be easily checked for both linearity and
minimum detectable limits. The dilution flask is set up with an amount of each impurity in natural gas
which far exceeds that found in pipeline gas. This mixture is then gradually diluted with pure methane and
readings taken every six minutes until the reading is 100% methane. Although it is theoretically possible to
do the absolute calibration using this technique, the apparatus available is not nearly as precise as the
primary certified standards available from todays gas blending laboratories. For this reason, the instrument
is first calibrated using a standard gas of a typical natural gas blend and then the exponential dilution is run.
The linearity of the instrument is independent of the calibration and could be checked without an absolute
calibration, but if the instrument is first calibrated and does prove to be linear, then all the minimum
detectable limits of each component are also determined. After system linearity is proven, each instrument
can be tested for linearity using two calibration standards. The repeatability of each instrument should be
tested over its entire ambient temperature specification prior to installation in the field.
INTRODUCTION
Gas chromatography is a method by which gas mixtures are physically separated into their individual
components and quantified. The on-line or process gas chromatograph performs this function on a
continuous basis. On-line BTU measurement of natural gas is accomplished by analyzing eleven
components of the gas and determining the BTU content based on the component mixture using appropriate
factors. This paper will not attempt to deal with the factors or formulas in converting mole percent to BTU,
277
but will focus on the ability of the process gas chromatograph to accurately and reliably analyze the
components in natural gas.
EQUIPMENT
The analyzer tested was the Daniel Model 500 equipped with the Model 2251 controller and the Epson
RX-80 printer to record the data. The dilution equipment is from Fisher Scientific. The primary certified
calibration gas used was supplied by Liquid Carbonic. The pure Methane gas was supplied by Matheson.
The gas chromatograph employs a three column system which allows a complete analysis through C6+ in
six minutes. (See Figure 1A & B).
LINEARITY DETERMINATION
One of the best methods of determing linearity of response of any gas analysis system is exponential
dilution. It is a simple method to set up and yields a large amount of experimental data over a relatively
short period of time. This is especially true in the case of a multi-component mixture. This method employs
a mixing flask of fixed volume with two inputs, one for starting gas, one for diluent gas and one exit for the
gas mixture. (See Figure 2).
The flask is initially filled with high concentrations of the components in natural gas. (See Table 1). This
mixture is then diluted with pure methane at a constant flow rate. With constant flow rate and proper
mixing, the concentration of each component can be related to time.
FIGURE 1A
BTU CHROMATOGRAM
279
FIGURE 1B
ANALYSIS REPORT
To determine how long it will take to dilute the starting 8% CO2 down to 10 PPM then:
or 16.7 hours. In the same manner, all the components values can be predicted and compared with the
printout for accuracy.
Starting with the mixture in Table 1 and diluting with pure methane, the linearity of every component can
be determined in one dilution. By plotting the natural log versus time, a straight line will be plotted if the
response of the system to the particular component is indeed linear. (See Figure 3). All components plotted
were found to be linear with all points within the repeatability listed in Table 3.
By plotting each component concentration as printed out from the integrator, the entire analytical system
is checked out. That is the detector, separating system, and the integration software and normalization
techniques are checked in the system as it will be used for BTU measurement. As a double check on the
computer, the natural log of the BTU contribution of each component can be plotted against time and will
yield the same graph as the concentration. Since all the components are normalized to 100%, this method
also proves the linearity of the methane measurement.
Once the analytical system design has been proven linear, extensive tests need not be continued on each
duplicate analytical system. Every time an instrument manufacturer changes design in either hardware or
software in the system, these tests must be run to insure the accuracy of the analyzer.
For duplicate systems of the same design, a simple two gas check can be run on each unit. A calibration
on a known standard gas of high BTU content and an unknown run using a low BTU standard gas can
suffice as a linearity check for individual systems.
280 LINEARITY AND RELIABILITY DETERMINATION OF BTU ANALYSIS BY PROCESS GAS CHROMATOGRAPHY
FIGURE 2
EXPONENTIAL DILUTION FLASK
MINIMUM DETECTABLE LIMITS OF EACH COMPONENT
Another useful piece of information derived from the exponential dilution is the minimum detectable limit
of each component. As each component approaches zero concentration, the analyzer will cease to reliably
detect it. Since the dilution is exponential, the data on the low end is very precise and the minimum detectable
limit of each component can be very accurately determined. For the run mentioned above, the lower
detectable limits were determined by taking the first run which read zero for a given component and
backing up five runs and using the actual value at that level. By backing up five runs (30 minutes) there is a
39% safety margin in determining the value. The values obtained are listed in Table 2.
281
FIGURE 3
TABLE 2
COMPONENT BTU CONTRIBUTION
Nitrogen 30PPM*
Carbon Dioxide 20PPM
Ethane 15PPM .03
Propane 20PPM .05
Isobutane 10PPM .04
n-Butane 8PPM .03
neo-Pentane 11PPM .06
Isopentane 20PPM .08
n-Pentane 16PPM .07
C6 + 8PPM.05 .05
* Diluent methane contained 56PPM N2 so nitrogen level determined by extrapolation of curve and comparison of
relative response of CO2.
As can be seen from Table 2, the maximum error due to not detecting every low level component is 0.41
BTU. This assumes that the gas analyzed has every component just below its minimum detectable limit. It
is obvious that this type of natural gas would be very hard to come by, and that for the average pipeline gas
the degree of error from sensitivity of the system is indeed negligible.
REPEATABILITY DETERMINATION
Any analytical system can only be as accurate as it is repeatable. That is, analyzing the same sample must
give the same result every time. To test the reproducibility of the chromatograph a standard gas was run for
24 hours and every run (240) analyzed for accuracy. The results are listed in Table 3.
282 LINEARITY AND RELIABILITY DETERMINATION OF BTU ANALYSIS BY PROCESS GAS CHROMATOGRAPHY
TABLE 3
Hi Reading Low Reading Concentration BTU
Component Concen. BTU Concen. BTU Error Error
Nitrogen 0.455 0.457 10 PPM .01
Methane 95.780 969.18 95.769 969.29 60 PPM .06
CO2 0.942 0.936 30 PPM .03
Etfiane 2.021 35.86 2.017 35.78 20 PPM .04
Propane 0.437 11.09 0.440 11.03 15 PPM .03
isobutane 0.109 3.55 0.108 3.52 5 PPM .015
n-butane 0.103 3.38 0.102 3.32 5 PPM .03
neopentane 14PPM 0.06 7PPM 0.03 5 PPM .03
isopentane 0.042 1.68 0.040 1.62 10 PPM .03
n-pentane 0.031 1.24 0.029 1.16 10 PPM .04
C6 + 0.091 4.80 0.089 4.71 10 PPM .045
BTU 1030.0 1029.8 0.1
Spc Grav. 0.5872 .5870 .0001
As can be seen from Table 3, the maximum deviation on the BTU value was 0.1 BTU. If all the individual
maximum errors in non-reproducibility occur in the right direction to produce the greatest error, it is
possible to obtain an error of 0.36 BTU. Although this is theoretically possible, it would be practically
impossible for all eleven components to be at their outside limits at the same time.
RELIABILITY DETERMINATION
There are several factors which affect reliability of the process gas chromatograph. The two major sources
of hardware failure are infantile failure of electronic components and failure due to wear in the moving
parts in the gas chromatograph valves. Preburning of all electronic components themselves and then burning
in all electronic boards in an environmental chamber will eliminate most infantile electronic failures. Failure
due to valve wear has been drastically reduced by the use of the diaphragm type valve as opposed to the sliding
plate valves previously used. A diaphragm valve which has no 0-rings or any need for lubrication has been
tested to as many as 5 million cycles without a failure. This is primarily due to the small distance in the
movement of the piston which is less than 0.001.
With the two primary hardware failures reduced to a minimum there remains one major cause of
analytical failure for a process gas chromatograph: fluctuating ambient temperature. This causes no failure
in the hardware of the system, but if not properly handled, can have a drastic effect on the analysis
accuracy. The process gas chromatograph should be mounted near the sample point for greatest accuracy
and thus will not usually be mounted in a temperature controlled environment. The fluctuating temperature
can cause many problems to a gas chromatograph that has not been designed to withstand a wide variation.
This is perhaps the major reason why the process gas chromatograph has been associated with high
maintenance. When temperatures changed the unit had to be adjusted.
The analyzer here was tested in an environmental chamber and cycled from 0 to 130F while running
analysis on known standard gas.
283
The analyzer was calibrated at 70F, then run for 8 hours at 0F. The temperature was then raised to 130
F which takes approximately 6 hours, and held at 130F for 8 hours, then lowered back to 70F. The results
are listed in Table 4.
TABLE 4
REPEATABILITY FROM 0 TO 130F
COMPONENT HI VALUE LOW VALUE REPEATABILITY
Nitrogen 0.440 0.413 .014%
Carbon Dioxide 0.548 0.537 .006%
Methane 97.082 97.050 0.016%
Ethane 1.100 1.093 0.004%
Propane 0.514 0.510 0.002%
isobutane 0.100 0.99 0.001%
n-butane 0.099 0.098 0.001%
neopentane 0.050 0.049 0.001%
isopentane 0.047 0.045 0.001%
n-pentane 0.047 0.046 0.001%
C6+ 0.020 0.018 0.001%
BTU 1030.1 1029.9 0.15 BTU
Spec. Gravity .5786 .5784 0.0001
References Cited
1. Colson, Ervan R., Flame lonization Detectors and High End Linearity, Analytical Chemistry 58, 337344 1986
February
ON-SITE ENERGY MEASUREMENT
R.A.Price
Measurement Technical Services Manager
Southern California Gas Company
Los Angeles, California 90051
ABSTRACT
Southern California Gas Companys entrance into the age of electronic measurement is discussed. Prototype
installations at their four out-of-state purchase points have been installed and are operating. The
measurement stations are located in the California Mojave desert where temperatures may vary by as much
as 50F to 60F or more on a daily basis and seasonably by more than 100F. On-site energy measurement
equipment has been installed at these locations and it is assumed that if the equipment will operate
satisfactorily at these locations, it will operate anywhere. Planned future installations, and their inherent
problems, will also be discussed at length.
On-Site Energy Measurement as described here is as follows: Its real time measurement, on site,
incorporating instrumentation to measure flow, specific gravity, % Nitrogen (N2) % carbon dioxide (CO2),
and heating value (BTU). These variables are all necessary for the measurement of energy (therms), which
is computed in real time, on site.
PILOT INSTALLATIONS
It is intended to install on-site energy measurement at all of Southern California Gas Company utility
electric generating plants as well as its wholesale customers (approximately 30 locations). Currently,
however, only four pilot installations are in and operating and these are at our own facilities. They are
located at Blythe, Needles, and Newberry Springs, the points where we measure the gas we purchase from
El Paso Natural Gas Company and Transwestern Pipeline Company, our major out-of-state suppliers. These
locations are all in the Mojave Desert and it is believed that if the equipment will operate under these severe
conditions, it will operate anyv/here. Temperatures at these locations may vary on a daily basis by as much
285
as 50F to 60F and on an annual basis by more than 100F. Before describing their installations in detail,
the current method of energy measurement will be described.
CURRENT METHOD
Several Company departments are involved in the currently used method of energy measurement. Division
personnel change the flowmeter charts, temperature charts and gravitometer charts on a regular basis. These
charts are sent to the Measurement office for processing. The Measurement Gas Analysis Center changes
sample tanks on a regular basis. These tanks are returned to the Analysis Center where they are analyzed for
specific gravity, % N2, % CO2 and BTU. These values are sent to the Measurement office for inclusion in
volume and energy calculations.
The Measurement office is where it all comes together. The flow meter charts are logged in, matched
with the appropriate temperature, specific gravity and/or pressure charts as applicable and forwarded to the
cleanup section which monitors the charts, cleans them as necessary, and determines whether they will be
read with the optical scanner or manually integrated. Extremely dirty charts cannot be scanned and must be
read manually.
At this point the chart readings obtained from scanner or integrator must be matched with the values
obtained from the Gas Analysis Center. This is performed manually on a special form. This form is then sent
to the EDP section where the energy units are computed and the bills prepared. Along the way, there are
many checks to hopefully preclude any errors.
ON-SITE METHOD
The on-site method currently being tested at the four pilot locations must have the capability of handling
multiple orifice meter runs (as many as twelve) as well as turbine or rotary meters. It must have the
capability of retaining several days information in 15-minute increments. This is because tariff rates can
change on short notice. It must incorporate real time specific gravity, % N2, % CO2 and BTU as well as
flow.
The four pilot installations are almost identical and consist of the following components:
1. A remote terminal unit (RTU) capable of retaining volume and energy units in 15-minute increments for
up to 72 hours. Also it must have the capability of two-way communications with the host computer.
2. A process chromatograph which completely analyzes the flowing gas at least every 15 minutes. This is
transmitted immediately to the RTU for inclusion in the volume and energy computations.
3. Differential pressure, pressure, and temperature transmitters for each meter run.
4. An uninterruptable power supply (UPS) capable of operating the system for several hours in the event
of a power failure.
5. Telephone modem to communicate all data to headquarters for billing and operating purposes.
MODE OF OPERATION
Under normal operating conditions the system will monitor volume and energy measurement continuously,
storing this data in 15-minute increments. At some regular time, the host computers (H.P. 1000) located at
headquarters, will poll the RTU, and extract the last 24 hours of data for billing purposes. In the event of a
286 ON-SITE ENERGY MEASUREMENT
tariff rate change at a time other than the billing period the RTU will have to be manually interrogated
through the host computer.
MAINTENANCE
It is expected that maintenance will be minimal but in the event of problems most diagnostic work can be
performed via the communications link. Calibration data on the process chromatograph is also readily
available via this link.
CONCLUSION
On-site energy measurement as described in the paper is being used by an increasing number of companies
in the sale of large volumes of gas. This has been made possible by the availability of more powerful and
less expensive microprocessors. As the upward trend in power, and the downward trend in cost continues,
on site energy measurement will be applied to smaller and smaller meters. Someday, in the not too distant
future, well probably see your home gas meter reading in energy units rather than cubic feet.
CONTINUOUS MEASUREMENT OF CALORIFIC VALUE
OF NATURAL GAS
M.Haruta, K.Uekuri and Y.Kiuchi
Asst. General Managers
Osaka Gas Company, Ltd.
Osaka 541, Japan
ABSTRACT
Osaka Gas Company has applied the correlation between the density and calorific value of natural gas to
indirect continuous measurement of calorific value. By developing measuring instruments and employing
existing instruments, calorific control of send-out gas and calorific monitoring of process gas have been
improved in our plant. (1) Rauter meter: This conventional instrument with its high reproducibility and
reliability has been used for calorific control of send-out gas at our Senboku Works. Five years of actual
operation have produced satisfactory results. (2) Sonic type: Developed by Osaka Gas, this equipment has
higher accuracy and responsity than a gravimeter. It utilizes the general correlation between the
sound velocity u and density of gas p. This system is applied to continuous monitoring during LNG
unloading. (3) Optical interferometer type: This calorimeter presently under development by Osaka Gas has
demonstrated high accuracy, reproducibility and responsity in the field trial. Measurement is made by
transforming the shades of interference fringes induced by the difference of refractive indices between
standard gas and sample gas into electrical signals. Simple and compact, the apparatus has great potentials
for control and monitor operations.
INTRODUCTION
Every year, about 12 billion cubic meters (equivalent to 10,000 kcal/Nm3) of town gas is distributed in
Japan, and about 65% of it is natural gas. Japan imports most of its natural gas in the form of liquefied
natural gas (LNG).
Osaka Gas Co., Ltd. imports LNG from Indonesia and Brunei to provide town gas for its customers.
Town gas in Japan is legally subject to quality control to ensure that the calorific value is kept at a constant
level.
288 CONTINUOUS MEASUREMENT OF CALORIFIC VALUE OF NATURAL GAS
Because, however, the ingredients of LNG vary somewhat according to its source and the conditions of
its liquefaction, the calorific value of the resulting town gas is subject to variation.
Osaka Gas maintains the calorific value of its town gas at 11,000 kcal/Nm3 by adding liquefied petroleum
gas (LPG) to the gas produced by vaporization of LNG. Calorific value control and monitoring of send-out
town gas is dependent on the existence of continuous measuring equipment with high reproducibility of
measurement and speed of response.
The fact that LNG import transactions are carried out on the basis of the BTU quantity of unloaded LNG
also lends importance to LNG sampling and analysis as well as to measuring the volume.
The commercial calorific value is determined from the value obtained by gas chromatographic analysis
of gas stored in a holder by continuous sampling of LNG during unloading. Highly sensitive continuous
measuring devices that respond rapidly to fluctuations are needed to enable stable monitoring of gas in the
holder during continuous sampling.
In the past, the combustion method was used for the continuous measurement of calorific value: gas was
burned at a constant rate, the resulting heat was transferred to water or air, and the calorific value was
calculated by measuring the resulting rise in the temperature of the water or air. Although the
reproducibility of measurements by this method is high, its speed of response is very low. The difficulty of
maintenance and its high price are further disadvantages.
The use of process gas chromatography was also once envisaged, but it proved totally unfeasible for
control applications, because roughly 15 minutes were needed to complete a measurement, even with high-
speed models. Thus a highly reproducible, highly sensitive, and rapidly responsive method of continuous
calorific value measurement was sought.
At Osaka Gas, we recognized on the close correlation between LNG gas density and its calorific value.
Our method of indirect calorific value measurement by gas density for control and monitor operations has
now reached the application stage.
This paper presents data on the performance and operation at Osaka Gass Senboku Works II of the
established Rauter calorimeter, a sonic-type calorimeter developed by Osaka Gas, and an optical
interferometer-type calorimeter currently under development.
CALORIMETRIC METHODS
1) Rauter meter
2) Sonic type [1]~[4]
3) Optical interferometry [5]~[7]
4) Vibrational method [8]
289
Rauter Meter
Principle. Measurement by this method is based on the proportionality of gas density to the pressure created
by an impeller rotating at high speed.
(1)
Composition and Functions of the Apparatus. Figure 3 is a schematic diagram of the Rauter meter. An
impeller rotating at high speed gives the air pressure torque to the second vane wheel in the chamber. This
torque is measured and compared with that produced by an identical impeller arrangement in a standard gas
(air). The Rauter meter has proven its worth through years of densitometric service. However, because it is
a purely mechanical device, its speed of response and sensitivity are limited. Its speed of response is
seconds, and its maximum sensitivity to
density is 0.001 of air (=1). According to Figure 2, this sensitivity corresponds to 15.2 kcal/Nm3. Thus
there are limits to the Rauter meters precision, but it is adequate for calory control and monitoring
purposes.
To achieve a higher speed of response and a target density sensitivity of 0.0001, we began development of
sonic -type[4] and optical interferometer-type calorimeters.[7]
Sonic-Type Calorimeter
Principle. The speed of propagation of sound waves in a gas is given by Laplaces equation, given below.
(2)
The speed of sound varies with temperature as follows:
(3)
Using these equations, we can measure the density, and therefore the calorific value of a gas, by measuring
the speed of sound in the gas under conditions of constant temperature. To measure the speed of sound, we
create a stationary wave in an acoustic cell of constant length and measure the frequency (f) at a constant
wavelength () from Equation (4) .
290 CONTINUOUS MEASUREMENT OF CALORIFIC VALUE OF NATURAL GAS
PERFORMANCE
Field tests with the optical interferometer were begun in March 1986; the figures in parentheses in
Table 4 are anticipated values.
299
APPLICATION
Figure 12. TIME SEQUENCE OF GAS SAMPLING OPERATION AND CALORIFIC VALUE DEVIATION
DURING LNG UNLOADING
CONCLUSION
Gas densitometers can measure, continuously and indirectly, the calorific value of natural gas, can
accurately control the calorific value of send-out town gas and can accurately monitor process gas.
Comparison with conventional combustion-type calorimeters, based on actual experience at the works,
reveals the tendencies shown in Table 5.
The optimal calorimetric method must therefore be chosen according to the intended application at the
works in question.
303
ACKNOWLEDGMENT
We thank Riken Keiki Corporation for the valuable cooperation in the development of the optical
interferometric calorimeter.
NOTATION
f = Frequency
n = Refractive index
P = Pressure
P = Wind pressure
t = Temperature (C)
V = Revolution rate
Vo = Velocity of sound (N.T.P.)
Vt = Velocity of sound (at tC)
= Ratio of the two heat capacities (Cp/Cv)
= Wave length
Po = Gas density (N.T.P.)
pt = Gas density (at tC)
LITERATURE CITED
[1] Crouthamal, C.E. and Diehl, H., Gas Analysis Apparatus Employing the Velocity of Sound, Anal. Chem. 20,
515520 (1948).
[2] Haswell, R., Development of the Sonic Gas Analyzer, Ind. Chemist. 38, 164166 (1962).
[3] Chimoto, S., Hirayama, T., and Yamazaki, H., Sonic Type Gas Analyzer ER62, Yokogawa Technical
Report 5 (Yokogawa Electric Corp.), 8488 (1958).
[4] Haruta, M., Combustion Property of Gas Measuring Apparatus, U.S. Patent 4246773 (1981) Jan. 27, Japan
Patent 1249799 (1985) Jan. 25.
[5] Namba, S., Photoelectric Recording Interferometer for Gas Analysis, Rev. Sci. Instr. 30, 642 (1959).
[6] Sugano, A., Automatic Alarm of Methane, Anzen Kogaku 10, 113119 (1971) Feb.
[7] Komachi, M., Method and Equipment of Gas Heating Values Measurement, Japan Patent 1294576 (1985)
Dec. 26.
[8] Ditcham, S., Gas Quality Metering, Pipeline & Gas Journal 212, 3642 (1985) Oct.
DIRECT MEASUREMENT OF ENERGY FLOWRECENT
FIELD EXPERIENCE
Carl H.Griffis
Project Manager, Gas Operations Technology
Gas Research Institute
Chicago, Illinois 60631
Dr. William H.Clingman, Vice President
Lyn R.Kennedy, Technical Staff
Precision Measurement Incorporated
Duncanville, Texas 75138
Dr.Kenneth R.Hall, Associate Director
Dr.James C.Holste, Associate Professor
Texas A&M University
College Station, Texas 77843
ABSTRACT
Two methods of measuring total energy flow have been compared with one another. The first method uses a
flow computer which has as inputs the pressure, temperature, and pressure differential from an orifice meter.
This method also uses continuous measurements of relative density and calorific value. The output from the
flow computer is the instantaneous energy flow. The second method uses a new energy flowmeter that is
under development. It directly measures energy flow without measuring either calorific value or volumetric
flow. This energy flowmeter has been operating in a test mode for about one year at a field metering site. In
this paper some of the most recent experimental results are presented.
INTRODUCTION
The Gas Research Institute has been sponsoring the development of a new approach for measuring the
energy delivered from a pipeline or distribution system. The heart of this method is an energy flowmeter that
measures directly the Btu/Hr of gas flowing down a pipeline. Traditionally this has been determined by
measuring volumetric flow, (scf/Hr), and calorific value, (Btu/scf), independently. These two quantities
have been multiplied together to obtain the energy flow, (Btu/Hr). The instrument that we have been
developing measures energy flow directly without measuring either volumetric flow or calorific value. This
avoids the problems normally associated with high precision measurements of volumetric flow and
increases the precision of the energy measurement.
This method was discussed in some detail at the August 1985 conference sponsored by IGT on Natural
Gas Energy Measurement. At that time, however, only preliminary results were available. This paper
provides an update of the experimental work. The energy flowmeter has been operating for several months
306 DIRECT MEASUREMENT OF ENERGY FLOWRECENT FIELD EXPERIENCE
on an eight inch pipeline in parallel with a flow computer that is also measuring total energy flow. The
installation is at a Lone Star Gas orifice metering site near Bryan, Texas.
In the following section of this paper the equipment at this installation is described. The data from both
methods are compared in order to assess the precision and linearity of the energy flowmeter. In the final
section of the paper conclusions are presented as well as a discussion of the continuing program.
MEASUREMENT METHODS
Two measurement methods are being compared at a test site near Bryan, Texas. One method is the
Precision Measurement Incorporated energy flowmeter, which has been developed under sponsorship by the
Gas Research Institute. The other method uses an orifice meter and calorimeter to provide inputs to a flow
computer that calculates the energy flow. The Bryan test site is an odorant injection station operated by
Lone Star Gas, which uses an orifice meter to control the odorant injection. The orifice run is in an eight
inch line, with gas flows varying between 500,000 and 1,000,000 scfh. The source of the gas is a Champlin
gas plant about five miles upstream from this site. Operations at this plant are variable, and the calorific
value can change rapidly over a 1000 to 1200 Btu/scf range. Gas leaving this measuring site goes both to a
municipal power plant and to the Bryan, Texas distribution system.
The energy flowmeter has two main components. These have been covered in detail in the previous
presentation(1) and GRI reports (2, 3). The first component is a flow separator which divides the flow into
two streams, a main stream and a sample stream. A specially designed flow constrictor is placed in each
stream. The constrictor in the main stream contains over 700 rectangular channels all of the same hydraulic
diameter. The sample stream contains a manifold of capillaries. A valving arrangement can direct the flow
through either a single capillary or a group of capillaries in parallel. A differential pressure gauge
continuously monitors the differential pressure between the sample and main line downstream from the flow
ccnstr ictors.
The sample flow which is split off from the main stream is burned in the second component of the energy
flowmeter. This second component is called a Flow-Titrator. The Flow-Titrator performs two functions.
It controls the sample stream flow to maintain zero differential pressure at the flow separator. It also mixes
the sample flow with a stoichiometric quantity of air and burns the mixture. The Flow-Titrator design is
patterned after the Therm-TitratorR, which is a commercial instrument manufactured by Precision
Measurement Incorporated for measuring the calorific value of natural gas. It has been established in
previous experiments that the ratio of the main flow to the sample flow is always the same and is
independent of the flow magnitude or the gas composition. Thus the air flow in the Flow-Titrator is in
direct proportion to the energy flow in the main line.
At the Bryan site the main line flow constrictor was installed flush against an isolation valve and a 90
elbow. This was done to establish worst case test conditions. It was expected on theoretical grounds that the
operation of the flow separator would be insensitive to upstream flow conditioning of the gas. Test data
taken to date has proven this to be the case.
The second method of measuring energy flow using independent measurements of volumetric flow was
provided by a Lone Star Gas orifice meter. Input to the Elliot flow computer included the pressure
differential across the orifice plate and the pressure and temperature of the gas at the orifice. A commercial
GB-2000 instrument from Precision Measurement Incorporated provided a continuous input of specific
gravity to the flow computer. Calorific value also was provided by the GB-2000. The flow computer used
these inputs to calculate the volumetric flow at standard conditions. It then corrected for
307
supercompressibility using the NX-19 procedure. The corrected volumetric flow was multiplied by calorific
value to obtain the energy flow.
EXPERIMENTAL RESULTS
Data was recorded over a period of several weeks using chart recorders to continuously record the output of
the energy flowmeter and the flow computer. The Flow-Titrator calibrated itself once a day on a fixed flow
of methane. The reading of the instrument was taken as a percentage of this fixed energy flow. The flow
computer output was in millions of Btu per hour, (MMBtu/Hr). This output was then used to calculate an
overall meter factor for the energy flowmeter. This was done every 30 minutes during a run. These meter
factors were averaged over the length of the run, which was always 24 hours or less. If there were no
random errors in either measurement method then this meter factor would be constant with time. The
random measurement errors, however, introduce a random error in the meter factor. From a statistical
treatment of the meter factor variations it was possible to place an upper limit on the errors in the
measurement methods.
The energy flowmeter was designed so that it could shift flow constrictors in the sample line. The ratio of
the main flow to the sample flow was called the split of the flow separator. The capillary and valve manifold
on the sample line allowed the split to be changed between four different values. This was done
automatically in response to changes in the main line flow. The micro-computer of the Flow-Titrator
selected the split as to keep the sample flow in the 24 scfh range which is the operating range of the
combustion system of the Flow-Titrator.
During the field test the split actually changed between two values. These corresponded to a high and low
range for the main line energy flow. In Table 1 the average meter factors are shown for each operating
range along with the date and times that the instrument operated continuously in that range. This defined an
operating period. Each time the range changed a new operating period was begun and a new average meter
factor was calculated.
For a given range there is some fluctuation in the meter factor from period to period. This is due to the
random errors in the two measurement methods. The weighted standard deviation was calculated for the
meter factors for each range and these are shown in Table 2. Since operating periods in a given range were
24 hours or less, the weighted standard deviation was an upper limit on the precision of measuring the daily
energy delivered by either method. It could be concluded from this data that the precision of either method
would be better than 0.3%. It could also be concluded that the energy flowmeter was linear over the range
of conditions at the Bryan test site. The meter factor was not affected by
TABLE 1
BRYAN TEST SITE DATA
Energy Flowmeter
Measurement Period Average Meter Factor
Date Begin Time End Time High Flow Range Low Flow Range Standard Deviation of Average Percent
10/13/85 1430 2400 8.38 0.69
10/14/85 0 2400 8.42 0.87
10/15/85 0 2400 8.46 0.68
10/16/85 0 1200 8.49 0.39
1230 1230 4.51 *
1300 2130 8.44 0.26
308 DIRECT MEASUREMENT OF ENERGY FLOWRECENT FIELD EXPERIENCE
Date Begin Time End Time High Flow Range Low Flow Range Standard Deviation of Average Percent
2230 2400 8.33 1.20
10/19/85 1300 2400 8.61 0.60
10/20/85 0 2400 8.59 0.53
10/21/85 0 830 8.52 0.45
10/23/85 1800 1900 4.71 0.50
2000 2000 8.63 *
2030 2400 4.63 1.18
10/24/85 0 1200 4.68 1.56
1230 2400 8.65 1.31
10/25/85 0 830 8.66 0.33
900 1100 4.66 1.63
1130 2200 8.66 0.93
2230 2330 4.62 1.10
2400 2400 8.67 *
10/26/85 0 2400 8.67 1.83
10/27/85 0 530 8.68 0.31
630 2400 8.72 0.47
10/28/85 0 1600 8.57 3.51
10/30/85 900 1200 4.68 0.31
1230 1600 8.74 0.25
10/31/85 0 1030 4.68 0.52
1100 1800 8.77 0.38
1900 2400 4.67 0.67
11/01/85 0 630 4.67 0.30
700 1900 8.99 0.98
11/02/85 1600 1800 8.94 0.43
2200 2400 4.74 0.44
11/03/85 1600 1800 8.85 0.41
1830 2400 4.76 0.86
* One Reading Only
TABLE 1 (Continued)
BRYAN TEST SITE DATA
Energy Flowmeter
Measurement Period Average Meter Factor
Date Begin Time End Time High Flow Range Low Flow Range Standard Deviation of Average Percent
11/04/85 0 600 4.80 0.32
730 730 4.80 *
830 830 4.87 *
309
Date Begin Time End Time High Flow Range Low Flow Range Standard Deviation of Average Percent
900 1600 9.07 0.61
2030 2400 4.81 0.55
11/06/85 900 1330 4.76 0.78
1400 1800 8.86 1.12
1900 2000 4.78 0.68
2100 2400 8.89 0.65
11/07/85 0 130 8.95 0.14
230 630 4.78 0.49
730 830 4.84 4.31
930 1730 8.90 1.21
1930 1930 4.70 *
2330 2330 8.88 *
2400 2400 4.74 *
11/08/85 0 130 4.77 0.18
230 430 8.94 0.29
530 630 4.78 1.64
730 800 4.81 1.37
830 1030 8.93 0.56
1200 2400 8.82 0.93
11/09/85 0 2400 8.77 0.69
11/10/85 0 1600 8.75 1.33
11/10/85 1800 2400 8.78 1.21
11/11/85 0 630 8.74 0.61
830 1730 8.93 0.76
2200 2400 4.76 0.64
11/12/85 0 300 4.76 0.43
330 800 8.86 0.98
830 900 4.81 0.77
930 1430 8.92 0.55
1530 1600 4.71 0.36
1630 2130 8.77 1.39
2200 2330 4.75 0.42
* One Reading Only
TABLE 1 (Continued)
BRYAN TEST SITE DATA
Energy Flowmeter
Measurement PeriodAverage Meter Factor
310 DIRECT MEASUREMENT OF ENERGY FLOWRECENT FIELD EXPERIENCE
Date Begin Time End Time High Flow Range Low Flow Range Standard Deviation of Average Percent
11/13/85 0 730 8.87 0.50
800 930 4.72 0.50
1000 1000 8.80 *
1030 1330 4.74 1.99
1400 1800 8.78 0.99
1830 2000 4.87 3.41
2100 2400 4.69 0.42
11/14/85 0 630 4.70 0.80
700 2230 8.77 1.31
2300 2400 4.70 0.28
11/15/85 30 30 4.65 *
100 730 8.79 0.66
11/16/85 600 730 4.81 0.35
830 1230 4.85 0.75
1400 1500 4.84 0.41
1900 2000 4.85 0.58
2100 2130 9.05 0.54
2200 2400 4.85 0.35
11/17/85 0 100 4.74 1.05
230 330 4.90 0.55
400 2400 8.95 1.32
11/18/85 0 1530 8.88 0.50
1630 2400 4.67 0.51
11/19/85 0 300 4.66 0.18
400 2400 8.79 0.83
11/20/85 0 900 8.91 0.38
930 1300 4.82 0.83
1400 1730 8.85
0.89
1830 2400 4.74 0.74
11/21/85 0 330 4.78 0.28
400 430 9.00 0.05
530 1500 4.81 1.24
1530 2100 9.07 0.70
2200 2400 4.83 0.65
11/22/85 0 100 4.81 0.19
130 530 9.10 0.35
600 1030 4.85 0.57
* One Reading Only
311
TABLE 2
WEIGHTED STANDARD DEVIATION OF METER FACTORS
Month Range Average of Meter Factors Weighted Standard Deviation
October High 8.56 0.9%*
October Low 4.66 0.3%
November High 8.86 0.2%
November Low 4.75 0.3%
* Drift due to Capillary Leaks.
variations in flow and calorific value. There was some drift in time of the meter factor for the high range,
and this was attributed to leaks that were found in the capillaries of the flow separator.
These leaks were corrected by redesigning the capillary manifold, and then a second set of experiments was
initiated at the Bryan site which are underway at the present time. Data collection was changed by replacing
the chart recorders with remote data collection. The output of the flow computer was input to the micro-
computer of the Flow-Titrator, which was programmed to calculate the meter factor continuously. One
minute averages of the data were then stored in memory. The micro-computer at Bryan also had
communications capability through an RS-232C port and external modem. Stored data was downloaded to
diskettes at the Precision Measurement Laboratory in Duncanville, Texas. The operating parameters of the
instrument as well as the program being run in the micro-computer of the Flow-Titrator could also be
modified at will from Duncanville using the same communication link. This system is currently being used
to further study the performance of the energy flowmeter, and a typical example of the type of data being
collected is shown in Figure 1.
Referring to Figure 1, the energy flow calculated by the flow computer is indicated by the symbol E, with
the Flow-Titrator measurement indicated by the symbol F. The vertical centerline represents the average of
all the measurements taken during the test period. Time increments on the vertical scale are two minutes,
with energy measurements on the horizontal scale in increments of 0.1%. As the chart indicates, the energy
flow meter and flow computer values track each other very well over a energy flow range of 3%.
CONCLUSIONS
The results have demonstrated that the energy flowmeter will measure energy delivered to a precision better
than 0.3%. This precision is based on a direct measurement of energy flow in a pipeline rather than by
combining measurements from several instruments. No correction is required for supercompressibility at
pipeline conditions and no corrections are required for pressure and temperature of the gas.
A principal advantage of the energy flowmeter is the relative ease of installation compared with an orifice
meter. In the experiments described in this paper the flowmeter was installed where there were worst case
flow conditions. No flow straighteners or straight run in advance of the meter were required. Even so, the
meter factors calculated during the experiments were independent of the total gas flow or composition.
The accuracy of the energy flowmeter will be limited by the accuracy of the calibration. This is the focus
of the ongoing work. A field test is being established with several participants to evaluate different
approaches to calibrating the energy flowmeter components. These field test sites will correspond to
different applications of the meter.
312 DIRECT MEASUREMENT OF ENERGY FLOWRECENT FIELD EXPERIENCE
FIGURE 1
COMPARISON OF ENERGY FLOWMETER AND FLOW COMPUTER MEASUREMENTS
REFERENCES
1. Clingman, W.H.; Hall, K.R.; Holste, J; and Kennedy, L.H., Field Experience in Measuring Energy Delivered
with Gaseous Fuels, presented at the IGT Symposium on Natural Gas Energy Measurement, Chicago, August
1985.
2. Clingman, W.H.; and Hall, K.R., Energy Flowmeter Development: Phase IGas Sampling Methods; Phase II
Prototype Energy Flowmeter, GRI Report 81/0200, December 1983.
313
3. Clingman, W.H.; and Hall, K.R., Energy Flowmeter Development, Final Report for GRI Contract No. 5083
2710938, January 1986, to be published May 1986
LONG TERM GAS SAMPLING AND HEATING VALUE
CALCULATIONS FROM GC-ANALYSIS
Klaus Homann, Dr.-Ing.
Head of Gastechnical Department
Vereinigte Elektrizitatswerke Westf. AG
Bezirksdirektion Dortmund
Ostwall 51, 4600 Dortmund, FRG
and
Hans J.Krabbe, Dr. rer. nat.
Head of Department for Organic Chemistry
Vereinigte Elektrizitatswerke Westf. AG
Hauptverwaltung
Rheinlanddamm 24, 4600 Dortmund, FRG
ABSTRACT
The following paper deals with methods of gas quality determination at VEW, a regional electric power and
gas utility in FRG. As far as relevance for the understanding of gas quality problems discussed here,
boundary conditions of the FRGs gas market are described in further detail in chapter 1. In chapter 2 we
mention some details of its marking general and gas specific regulations concerned with utilisation and
account problems arising from varying gas qualities throughout a complex network. Chapter 3 gives a
survey over recent developments in meeting continuously increasing requirements of customers and official
authorities in this field. Chapter 4 is concerned to a VEW-development of a microprocessor (P)controlled
gas sampling unit for solving special problems in the field of gas quality attachment, while chapter 5 finally
reports some aspects of GC-apply in FRG and experiences of VEW in that field.
1.
FRGS MARKET FOR NATURAL GAS
Despite a short-term decline the total primary njiergy consumption of the FRG has reached a value of
111018 Joule per year. Among this only a part of about 30 % is from domestic origins so that 70 % mainly
in form of oil and gas have to be imported from other countries, western as well as eastern ones, with all
inherent technical and political risks.
The contribution of natural gas to total energy consumption is about 20 %, in the room heating sector
even 27 % (Figure 1). The important role of natural gas for the energy supply is clearly pointed out by this
few facts. On the other hand it is obvious, that securement and diversification are essential demands.
One third of gas consumption is produced from our own resources, the other two are imported from the
Netherlands, the USSR and the Norwegian North-Sea. So far we can state, that the dominating part of gas
315
2.
DIFFERENT GAS QUALITIESAPPLY AND ACCOUNT PROBLEMS
Apply problems
During the past, varying gas compositions mainly caused apply problems at industrial and household
burners. Being aware of the fact, that all types of combustible gases would be used in public gas markets,
the private german technical advisory committee for the gas industrythe DVGWdismissed in 1939 G
260: Technical rule for gas quality. This technical rules, presently in revision again, should be interpreted
as a frame work for gas delivery, running of gas-burners and their development and standardisation. Beyond
317
this indications are given, up to which degree gases of different qualities can be intermingled without apply
problems.
G 260 devides the whole scope of combustible gases into 4 major families:
Especially all inland productions and imports of natural gas can be attached to one of the two groups of the
2nd gas family. Consequently the range of quality defining valuesheating value and densityis rather
wide. The ratio of heating value Ho and square root of density, the so called Wobbe-Index may vary
within the whole family about 17 % and within each group about 7,5 %, a tribute to diversification of
gas procurement and integration of pipeline networks.
During the whole time of application of G 260 for useability of different gases for public supply, burner
technology has reached a high standard. Only inferior problems occur with radiation heaters and gas
engines, sometimes not being suitable for the whole quality range permitted. On the other hand steadily
increasing prices for gas in households and increasing importance of gas as a production factor in industrial
processes caused an increasing interest in measurement and account accuracy.
Account problems
During a long time delivered gas quantities were merely accounted by measuring the gas volume. Quality
details (heating value) and values of thermal state (pressure and temperature) were hidden in the gas price,
fixed by the supply service. With increasing energy costs more and more suppliers went over to another way
of account, more traceable for the customers: heating value, pressure and temperature were actually
mentioned within the statement of consumption, so that, following official demands, the DVGW dismissed
a special ruleG 685; Enforcement on thermal billingin 1982. The primary intention of the official
authorities was to define areas of flowrate and measuring pressure with prescribed types of pressure
regulators and state correction procedures. Beyond this, boundaries for estimating time means or flowrate
weighted means of heating value ( 1% !) were fixed. An additional paper to G 685, presently in work, will
give further details of what to do, if different gas qualities are intermingled in integrated networks.
Accuracy of heating value attachment will be a central theme. Up to now, only the minimum accuracy of
actually installed measuring equipment is prescribed. We will now give a rough sketch on present FRG-
standard. For further detail the reader is referred to additional literature .
numerical procedures. AGA NX 19formula is usually taken for this. That means, that heating value,
density and CO2-partition have to be measured. Because of microprocessors becomming more and more
cheaper, electronic state correctors are in advance, on basis of a state equation as well as on basis of density
measurement on working conditions.
By the few numbers on measuring accuracy mentioned above it is pointed out, that official authorities in
FRG require a degree of accuracy, which manufactures are just able to guarantee. On the other hand it is
obvious for everyone, that handling problems of varying gas quality especially with respect to smaller
household consumers has not reached that standard. The next chapter shall deal with efforts of various german
companies in this field.
3.
FRG-TRENDS IN HANDLING OF VARYING GAS QUALITIES
Conventional Methods
During a long area in german gas utilisation history coke oven gas and natural gasinland production and
imports from Netherlandwere of same importance for supply. Consequently the present transportation
network, which was erected during the past 40 years, arose from smaller local high pressure networks in the
regions of coal and steel production. The overall length of the german pipeline network today is 165 000 km.
Although the steadily growing gas market forced more and more new gas qualities to be made available
for the customers, high heating value gas from the North Sea (~12 kwh/m3), russian imports with a little bit
lower value (~11 kwh/m3)it could be managed to keep them separated from each other to a certain degree.
If necessary, mixing stations were built, for mixing natural gas with air or coke oven gas or, vice versa, coke
oven gas with liquid gas for lower pressure ranges.
Already when only coke oven gas was distributed, calorimeters became widely in use for quality control.
Up to now calorimetry is the only officially permitted method to determine heating values. This is due to the
fact, that relevant german law requires officially licensed and supervised equipment for measuring values,
which are used directly or indirectly (!) for accounting purposes. Cutler & Hammer Calorimeters e.g. have
such a license for FRG.
Calorimeter technique still is a too costly method, to be used at every billing point in a complex network
with local or time variations of gas quality. The installation of gas samplers at certain characteristic points
within the network is a cheaper alternative. The american system Arco Anubis is a well known
instrument also in germany and widely in use. Being independent of any electric supply its inset is
advantageous in desert areas, but it has some disadvantages, as e.g. being unable to take samples in flow
rate proportional intervals, that caused us to develop a new technique, which we will describe later. A new,
rather sophisticated method of facing quality attachment problems shall be mentioned first.
are known, the corresponding data at any points especially those of billing can be calculated. Obviously this
method is only suitable in bigger transmission networks. An official working allowance was given under the
condition that it is used together with a master calorimeter. Another field of apply will be in planning
representative locations for conventional measuring equipments as described above.
4.
P-CONTROLLED GAS SAMPLING
The high pressure network of VEW as shown in Figure 3 presently is divided into three major quality
districts each separately run: the north western part is operated with natural gas, group H, mainly from the
Norwegian North Sea, a smaller south western part delivers H-gas as well, but with reduced russian quality.
The whole eastern part is run with natural gas, group L, of different netherland and german origins.
Especially within the L-gas region local and time variations of heating value in a range of 10 % have to be
handled. Further network separations were rejected with respect to supply security. Unsteady network flow
calculation could not be used, because a nonneglectable part of the high pressure offtake is not permanently
registered. Therefore, being aware of some disadvantages of the ArcoAnubis Gas Sampler VEW
developed a new one, consequently adjusted to VEW demands. Some of these demands are listed
underneath :
After all an apparatus was constructed consisting of two parts: a control unit outside the explosion area and
the sampling facilities as e.g. valves, pressure and temperature transducers and the sample container
(figure 4) inside the gas station. The working principle is as follows:
Sampling Method. The physical properties of natural gas in a sampling cylinder of constant volume are
exactly described by the thermal equation of state. The mass in the cylinder can be calculated, if the
pressure, the temperature and the composition of gas are known. Since the pressure and the temperature can
be measured easily, the only unknown variable is the composition of gas for the calculation of the gas
constant R and the compressibility factor Z. The composition, however, varies only in a small range, so that
an averaged value can be used for calculation. This favors the evaluation of the thermal equation of state as
a very effective and precise tool in gas sampler technique.
At the beginning of the sampling period the microcomputer obtains the increase in mass for one sample
from
320 LONG TERM GAS SAMPLING AND HEATING VALUE CALCULATIONS FROM GC-ANALYSIS
Now that the mass per sample is fixed, the corresponding pressure increase p in the sampling cylinder is
derived from
The indices i and i+1 denote for two consecutive samples. p is generally different for every sample
since T is now the actual temperature and Z depends on p and T.
In order to recognize possible leakage pressure and temperature are checked before the next sample will
be taken. The pressure has to correspond to the temperature at the constant volume of the sampling cylinder
according to the state equation. A deviation indicates a leakage which is reported by the computer.
Sampling unit. The sampling unit is connected to the gas pipeline by a line. Figure 4 shows the
mechanical components of the gas sampler schematically. The essential parts are:
321
solenoid valves V1 to V5
metering valve MV
Pressure regulator PR
vacuum injector VI
transducer for differential pressure PDI
transducer for temperature TI
sampling cylinder SC
The sampling line contains the micron filter MF and the oortion-volume PV between the solenoid valves
V1, V2 and V3. The blow-off line, connected to the outlet of valve V3, is used to purge the sampling line
and to evacuate the sampling cylinder by means of the vacuum injector VI at the beginning of the sampling
period. The pressure regulator PR guarantees, that the pressure in the vacuum injector is always in the
operating range. To prevent reflow from the sampling cylinder into the gas pipeline a check valve CD is
mounted behind valve V2. The following metering valve MV reduces the flow rate, which results in a
smooth pressure increase in the cylinder. On top of the sampling cylinder two needle valves NV1 and NV2
are mounted. To obtain a complete gas exchange by purging the cylinder, valve NV1 is equipped with a
tube which goes down to the bottom of the sampling cylinder. Valve NV2 is connected to the differential
pressure transducer PDI and to the pressure gauge PR, which gives a rough idea of the cylinder pressure.
The operating range of the differential transducer is 500 mbar. At the beginning of each sample valve V4 is
actuated, to zero the pressure difference over the transducer. The use of a differential pressure transducer in
connection with a 12 Bit A/D-converter yields a high resolution of the pressure signal. Valve V5 shuts off
the blow off line. As an additional security against loss of samples, caused by a possible leakage of valve
V5, a hand-actuated ball valve BV2 is mounted in the line. The gas temperature, used in the determination
of the pressure increase for each sample, is assumed to be equal to the cylinder surface temperature which is
measured. This is a resonable assumption since the heat capacity of the cylinder is large compared with the
capacity of one sample.
The sampling cylinder can either be exchanged at the end of a sampling period or the samples can be
transferred to a portable cylinder via the blow-off line.
Control device. The control device is mounted in a standard 19" rack. It contains the power supply for the
solenoid valves, the power supplies for the transducer, a 12 Bit A/D-converter and the microcomputer. The
microcomputer is equipped with a battery-buffered RAM and a restart logic to restart automatically after a
power fail. The faultless operation of the system is controlled by a watchdog. The device is operated by
menu, displayed on a 440 alphanumeric LCD-display, and a keyboard with 10 numeric kevs, 5 function
keys and a key operated switch to disable certain commands.
At the backside of the control unit a Centronics style printer port is installed. A serial data port for
communication with a host computer is optionally available.
Three electrical lines reflect the states of the gas sampler and can be evaluated by a remote control station.
These are:
Operation. Before the different phases of operation are described some fundamental features, of the device
should be mentioned. The device has three different states of operation: the STAND-BY, the ACTIVE and
the WAIT state.
In the STAND-BY state the microcomputer is ready to accept the START command in order to begin the
sampling period. After starting, the sampler is in the ACTIVE state. When all samples have been taken the
sampler returns to the STAND-BYE state. The WAIT state is entered upon the occurence of a fatal error or
by manual interaction. No samples will be taken in the WAIT state.
There are two informational features which are most important. The first is the error list in which every
error that occurs is entered with its error description and a time stamp. The error list provides space for 20
errors, beyond that the latest error supersedes the oldest one. Among the different error messages there are
leakage, low intake pressure, malfunction of pressure and temperature probes and power fail. The second
feature is the logbook in which all important events and parameters (also errors) are noted. Informations like
begin and end of sampling including pressure and temperature, deviation from the calculated pressure
increase, time of entering the WAIT and all operator interactions which might endanger the flow rate
weighted sampling are logged. The logbook can be printed at any time to check the proceeding of the
sampling period.
Start of sampling period and first sample. At the beginning of a sampling period the operator can choose
the number of samples to be taken and the end pressure of the sampling cylinder, which can be as much as
95 % of the lowest possible pipeline pressure. The components of H0, CO2 and density ratio can be entered
according to the latest gas analysis to evaluate the composition dependent parameters R and Z. The
microcomputer then calculates the mass per sample. If this mass is too small with respect to a preselected
error limit the microcomputer issues a warning.
The number of pulses from the state corrector or the internal clock can be entered to define the flow rate
or the time between the samples. Thereafter, the device can be started to begin the sampling period. The
microcomputer first checks if the cylinder is still pressurized to avoid the possible loss of unanalyzed gas. If
this is not the case the device starts purging the cylinder with pipeline gas. The purging gas is blown off into
the open air and the sampling cylinder takes atmospheric pressure. After the purging has been completed
successfully the further proceeding depends on the level of the pressure for the first sample.
If the pressure which is calculated according to equation (2) is below 1 bar (which is normally the case)
the pressure in the sampling cylinder is lowered by the vacuum injector to the calculated value. The lowest
possible pressure the vacuum injector can achieve is 100 mbar. If the pressure for the first sample is above 1
bar pipeline gas will be added up to this pressure.
Sampling. Every time, the given number of pulses from the state corrector is counted, a sampling phase is
initiated. At the beginning of this phase the microcomputer measures the pressure of the cylinder and
checks if the pressure has changed significantly since the end of the last sampling phase. Pressure changes
due to temperature are taken into account and not rated as leakage. If a leakage is stated the microcomputer
enters the appropriate error message into the error list and the logbook and continues operation. Only in
case the pressure transducer has been found faulty the microcomputer interrupts the normal operation and
enters the WAIT state.
At the beginning of a sample the microcomputer checks if the pressure in the pipeline is high enough to
drive gas into the cylinder. This is done by passing the contents of the portion-volume (see figure 4) into the
cylinder. If this does not cause a significant pressure increase in the cylinder the pipeline pressure is too low.
The reason for this could be, that the end pressure of the cylinder was chosen too high or the pipeline pressure
has dropped for some reason. The system then tries to recover the sample every 15 minutes. The corresponding
error message will be written into the error list and the logbook.
323
Sampling continues with the continuous filling phass. Valve V1 and V2 are opened to allow the gas to
flow into the cylinder until 95 % of the calculated pressure increase is reached. The system then waits until
the pressure has settled within a certain limit. The remainder of the desired pressure increase is
supplemented in discrete steps using the portion-volume. After each step the system waits again for a stable
pressure before the next cycle is started. This process is repeated until the deviation from the calculated
pressure increase is a minimum. At the end of the sampling phase valve V4 is opened to reset the differential
pressure transducer to zero. As already mentioned all important data of the sampling phase are noted in the
logbook in order to make the process transparent to the operator.
Man/machine interface. The man/machine interface was designed to allow for an easy and fail-safe
operation with a minimum training effort for the personal. The dialog with the microcomputer is performed
by menu. Each menu shows clearly all functions and commands that can be activated in the actual system
state. Just three keys are necessary to control the command dialog. A CURSOR is used to jump from
command to command. An EXECUTE key is used to activate a command, a STOP key to terminate the
command execution. All commands and messages are written in clear text. No error or function codes are
used.
Two different access rights can be chosen with a key operated switch. For example in the STAND-BY
state with the key operated switch set to the FREE position the operator can start the sampling period, read
and write all system parameters, display the actual pressure and temperature, display the error list, print out
the logbook, perform test functions.
A LOCKED switch allows the operator only to read all system parameters, display the actual pressure
and temperature, display the error list and print out the logbook.
The WAIT key can be used to force the device into the WAIT state. When a sampling phase is in
progress it will be interrupted and can be resumed later by means of the CONTINUE key. This is useful for
the case that for example some repair work is going on in the gas station or even at the gas sampler itself
and the normal sampling procedure can not continue.
The real-time/multi-tasking operating system, that runs on the microcomputer, enables parallel processing
of different tasks. When for example sampling is in progress the parameter dialog can be performed as well.
The ability of parallel processing is most important if the remote interface option is installed to allow the
remote computer to access the gas sampler at any time.
5.
SOME REMARKS ON GC
1. 2 m1/8 molecular sieve 13, separating hydrogen .(H), Ar, N2, C4 and CO. Detection by TCD. 4
min with t=45C then heated to 70C with 5C/min (figure 9).
2. 5 m1/8 gaschromQcolumn with 10 % silicon oil SE 30. The components CO2, C2 and C3 are
separated afterwards on a 1,5 m1/8 -Porapak -R column and detected by TCD. Beyond C3 the valve
in figure 8 switches the SE 30 column to the FID so that C4 to C8 can be detected. The oven is operated
at first 14 min with 35C and then heated up with 9C/min to 130C (figure 9 and 10).
occur. The good accuracy shows, that GC is a suitable method for energy measurement and that all effort of
manufacturers and users should be done, to achieve an official licensation for this method in FRG.
REFERENCES CITED
/1/ Herning, F., Wolowski, E., Kompressibilitatszahlen und Realgasfaktoren von Erdgasen nach neuen
amerikanischen Berechnungsmethoden, ges. Ber., Ruhrgas 15, (1966)
327
ABSTRACT
Due to a changed situation, both with imported natural gas and with our own production, it is not always
possible to maintain a constant gas quality. Because the possibilities of conditioning and distribution are
limited, security of supply must take absolute priority. In this paper, measuring systems are described which
are able to determine heat quantities accurately with the help of certain processing routines. These systems
will assume ever-greater importance on account of todays energy prices. Besides the measuring systems,
possibilities of measurement recording and processing are described. The following procedures are
discussed:
INTRODUCTION
Three fourth of the natural gas consumed in Western Europe came from indigenous production, one fourth
from imports (Fig. 1). Some 15 % are imported from the USSR and about 9 % from Algeria and Libya.
331
GAS DISTRIBUTION
BEBs gas transport system includes several compressor stations, tie- in and crossover points as well as
cavern and pore storage pools. Almost the whole of the pipeline system has been looped, so that high and
low-calorific gas can be transported separately (Fig. 5).
H gas imports from the Norwegian and Danish North Sea sectors and L gas imports from the Netherlands
are fed into these systems. Our own gas fields are mainly located in the South Oldenburg and East
Hannover areas. Some of the gases produced in these areas are strongly sour with H2 S contents of up to 25
% v or have N2 contents of up to 70 % v. This makes it necessary to operate large-scale gas purification
plants. In South Oldenburg, a high-calorific gas is obtained by means of Purisol and Sulfinol purification
processes, with some 500,000 tons of elemental sulphur per year being obtained as a by-product. In East
Hannover, nitrogen is removed from the gas in a low-temperature plant in order to get a salable L gas of the
1st gas family in accordance with DVGW specification G 260 (ref. 1). Furthermore, high-calorific gases
are conditioned with gas having a very low calorific value (Apeldorn, Ho< 4 kWh/m3) so as to obtain an L
gas of Slochteren quality. Despite these measures being taken on the supply side, different quality ranges
involving changing and fluctuating gas qualities are encountered on the demand side in gas distribution. In
addition, some areas show the phenomenon of fluctuating quality ranges.
332 HEAT QUANTITY DETERMINATION IN LONG DISTANCE GAS TRANSMISSION
corrected retroactively. Table 1 shows the correction systems used by BEB, distinguished by measuring
pressures and volume throughput. It can be clearly seen that for higher measuring pressures the K value
influence is already largely taken into account when making the corrections.
As can be seen from Fig. 8 for high measuring pressures and large volume throughputs, density flow
meters are mainly employed, which take the compressibility factor into account directly in the correction
process, even in the case of wide variations in gas quality.
MEASURING ERRORS
It has to be mentioned, however, that the density flow meters currently in use are subject to systematic
deviations resulting from the velocity-of-sound effect. The deviations of our sales gas qualities are around
0.2 %. This can be corrected or avoided by means of a calculation procedure or by using density
transmitters with low frequencies of oscillation.
Another possibility of correcting the velocity-of-sound effect is a recalibration of the transmitters or direct
sound velocity measurement.
The above-mentioned measuring errors are small, however, in comparison with errors already made when
measuring volumes at flowing conditions. In Germany, the calibration error limit when measuring air under
atmospheric pressure in the permissible measuring range is 1 %. The error may be much greater with
measuring conditions involving natural gas. Such errors can, however, be minimized by means of a high-
pressure calibration of gas meters. A high-pressure calibration has the additional advantage of extending the
permissible measuring range, thereby also reducing the minimum flow problem.
Figure 8. Number of Employed Corrector-Systems Taking into Account Pressure and Volume and Flow
Figure 9. Load Curve and Heat Quantity Deviation of Local Public Utility
MINIMIZATION OF MEASURING ERRORS
In view of energy costs, the minimization of measuring errors is gaining ever greater importance. Whenever
possible, balancing of supplies and offtakes is a suitable method to detect measurement errors, although this
is restricted to areas with an identical quality. As in many cases suitable balancing areas are not available
and balancing measurements are often too expensive, the single measurement must be subjected to a
suitable checking procedure. Most of the volume meter runs in BEBs system have therefore been equipped
with a standby run. By means of suitable piping, the main meter run and the standby run can be connected
338 HEAT QUANTITY DETERMINATION IN LONG DISTANCE GAS TRANSMISSION
Figure 10. Load Curve and Heat Quantity Deviation of a Transmission Company
Figure 11. Load Curve and Heat Quantity Deviation of an Industrial Consumer
in series. In order to avoid continuous operation of the standby meter runs and to have them ready for use in
the case of malfunctions, such series connections have so far in most cases been made only two or three
times a year.
This results only in random results depending on the meter loads prevailing at the respective times. Major
deviations can be detected in this way. Also corrector checks at certain intervals belong in this category. It
is very difficult to determine a drifting of gas meters or correctors, and even impossible to record the time
of mal-functioning. For this reason the German gas industry has for some time been testing or applying
continuously operating checking systems. In most cases they consist of two different metering systems (e.g.
vortex meter and turbine meter) which are connected in series. If a calculated deviation is exceeded, an
alarm gives the information, that the measurement equipment should be tested imediately. For stations with
small throughputs a standby meter run is not required. If the throughput is, however, equal to or greater than
150,000 m3/h (Vn), it is advisable for economic reasons to provide also for independent operation of the
meter runs in the case of a malfunction.
In additon to continuous Vn onitoring of the meters, BEB is currently making continuous corrector
checks on a test basis in small metering facilities. The meter runs are equipped with additional pressure and
339
Figure 12. Load Curve and Heat Quantity Deviation of a Power Station
temperature transmitters, whose measuring results are recorded on magnetic tape as hourly averages
together with the volumes at flowing conditions. After exchanging the magnetic tape cartridges, the hourly
volumes at flowing conditions are calculated by the central data processing function, taking into account the
K value, and are compared with the normal volume per hour from the corrector, which is also stored on a
recording medium. In this way it is possible to reduce off-normal periods to one hour and detect any drift at
a very early stage. As soon as such a trend has been determined, a meter check is made on site. Such a
system does not require any routine checks. This applies in particular to the combined operation of
computers in gas offtake stations with a central computer, periodic calling up of measured data from the
stations via acoustic coupler and remote data transmission, as well as automatic preparation of measured
values in the offtake stations with the aid of small computers to the greatest possible extent.
However, gas offtake regulation by the customer continues to be a problem. When determining actual
capacity offtakes, an exact heat volume dispatching is of crucial importance, in particular in view of the
very high capacity charges.
Customers without calorific value metering can regulate their offtakes only by means of a pre-set average
calorific value. In view of the necessary safety margins it is not possible to make economically optimum use
of the contractually provided volumes, even when an arithmetic average of the upper calorific values is used
for invoicing purposes.
An accurate heat volume regulation is only possible if the periods for heat volume formation are shorter.
This calls for investments, however, in calorific value metering, small computers and the relevant software.
Such regulating procedures, e.g. also by process computer, are only economically justified in the case of
large throughputs.
SUMMARY
Summarizing it can be said that the various different calibrating standard legally prescribed in Europe
specify only minimum accuracies for metering equipment. However, mainly because of the cost of energy,
both the gas industry and the customers are interested in arriving at much more accurate measuring results.
At the same time it must be ensured that the steadily increasing number of data can be provided at ever
shorter intervals so as to be able to meet the contractual payment dates and avoid interest-related losses.
340 HEAT QUANTITY DETERMINATION IN LONG DISTANCE GAS TRANSMISSION
In this connection, systems meeting the requirement of reducing the costs of local meter checks in the
stations, thereby making energy measurement more economic, will gain more and more importance in the
near future.
REFERENCES CITED
1 DVGW G 260/1 Gasbeschaffenheit
2 DVGW G 492/II Gro-Gasmessung
3 DVGW G 686 Thermische Gasabrechnung
4 G. Strulik, gwf-gas/erdgas 124/83, Vol. 3, p. 165 pp.
5 PTB, Richtlinie G 9
STATUS OF FEDERAL REGULATION OF NATURAL GAS
AND ITS IMPLICATIONS FOR FIELD APPLICATIONS OF
ENERGY MEASUREMENT
Paul D.Hubbard
Special Assistant to the Director*
Office of Pipeline and Producer Regulation
Federal Energy Regulatory Commission
Washington, D.C.
Introduction Changes in the federal regulation of natural gas can have implications for energy
measurement. A particularly significant example relates to the procedures for determining the quantity of
energy units involved in wellhead sales and other first sales of natural gas. That feature was the subject of
the Federal Energy Regulatory Commissions so-called BTU Rule, which was issued to implement the
wellhead pricing provisions of the Natural Gas Policy Act of 1978. This paper reviews some of the
technical aspects of the BTU Rule and discusses the expected future implications of federal regulation on
natural gas energy measurement.
I.
The Natural Gas Policy Act of 1978
B. Effects of NGPA
II.
Wellhead Pricing Approaches
III.
The BTU Rule
1. Imputed 820 pounds of water vapor per million cubic feet of total gas
2. Physical limit on guantity of water vapor
3. Contract limit of 7 pounds of total water per million cubic feet of gas
B. As-delivered basis for determining water vapor content and resulting guantity of BTUs
IV.
Concerns over effects of BTU Rule
V.
Court review of BTU Rule
VI.
Implications of Future Regulation for Natural Gas Energy Measurement
Conclusion The controversy surrounding the so-called BTU Rule has been resolved by the U.S. Courts.
Perhaps a lesson to be learned from this controversy is that, even when a U.S. Court may be impressed by
scientific accuracy, the court has the last word because it interprets the law.
This does not mean, however, that technical accuracy should not be strived for in natural gas energy
measurement. What it does mean is that, when the scientific community has imput in the formulation of
proposed legislation and regulations, technical advise should be clear and unbiased. If this approach is
followed, scientific accuracy could be fully considered and accounted for. The overall result should be that
scientific accuracy and all other relevant considerations are properly balanced in laws and regulations.
With the passage of time, an increasing portion of natural gas will not be governed by existing price
regulations. Additionally, some of the Maximum Lawful Prices under the Natural Gas Policy Act are above
current market clearing prices and some contract prices. This relationship should continue for at least as
long as oil prices remain low and gas inventories remain high.
Where federal price ceilings do not exist, or where price ceilings are above market prices, contracting
parties are free to adopt mutually acceptable provisions to accurately account for energy measurement. Such
provisions would, however, have to be coupled with pricing provisions which recognize and adjust to
market competition. The logical implication is that improved accuracy in natural gas energy measurement will
be increasingly important.
Note: All of the comments by the author are offered as general information for discussion purposes. They
are not presented as an official view of the Federal Energy Regulatory Commission. Neither are they
intended as a specific recommendation on any matter or issue.
344 STATUS OF FEDERAL REGULATION OF NATURAL GAS AND ITS IMPLICATIONS FOR FIELD APPLICATIONS OF
ENERGY MEASUREMENT
Ref: Adapted from Katz, Cornell, Kobayashi , Poettmann, Vary, Elenbaas and Weinaug, Handbook of Natural Gas
Engineering (McGraw-Hill Book Company, Inc., New York, Toronto, London, 1959). Reprinted with permission
1959 McGraw-Hill Book Company, Inc. GPO 879 235