‘SET THE FOLLOWING PARAMETERS ON THE MACHINE
Press the [Parameters] button for parameters settings
Press the [PAGE DOWN] button and select the ‘Settings 2' submode
Set the "MODE SELECT switch to "MOT"
Set the 'NO PWE’ parameter to 1 and press the Input button, After changing parameters below, change this
value to 0 again
Select the "Setings 2 submode
Set /0 = 1
With help of 'PAGE DOWN’ and ‘PAGE UP’ buttons change bits in the following parameters.
Please, don't change bits that didn't print in the table below
#002 (stop bit and data format)
bio
bit2
bia
#0552 (baud rate). Set this parameter
Baud
2400
4800
9600
18200
#0038 (10 device)
oe
ona
ota
oes:
mite
bt7
#0051 (Parity)
bit
O(E stop bi)
0 (RS232)
1 (Ascu),
Parameter value
9
10
u
2
4 0¥es)‘#0055 (Additional parameters)
bio. 1 (asc)
bit 1 ‘occr)
bit2 1 (Pratocol A)
bt 0(Rs232)
‘SET THE FOLLOWING PARAMETERS ON THE PC
SERIAL PORT TAB
Machine name Fanuc oF
Sera port ‘CoM (or any free COM port)
oud 2400
Data bits 7
Panty even
Stop bts 2
DATA FLOW CONTROL TAB
Use OTR False
Use RTS True
Require DSR Fake
Require CTS True
Set RTS False
Set DTR False
Software Nowcoitro None
Xon char a
off char #13
DATA EXCHANGE FORMAT TAB
Format mode Uniform
Program start %
Program end: 96
Line start:
Line end: #08,
Format parameters ‘Skip ines:
Tgnore characters: No characters for remove
Remove blank ines: No
Program name prefix: 0
Program starting characters in the Mle: No