You are on page 1of 8

Distribution transformers

Green distribution transformer program


Partnership for a sustainable environment
Introduction

Did you know ABBs line of distribution transformers can ABB is the leading, global transformer manufacturer.
reduce operating costs, energy bills and overall ABB offers a complete portfolio of single-phase and three-
environmental impact? phase pole- and pad-mount liquid-filled distribution trans-
Our low-loss transformers can decrease electrical losses formers, ranging from 15 kVA to 10 MVA, up to 36 kV. All
significantly. In fact, if all transformers were replaced by amor- products in our portfolio are in full compliance with IEC and
phous metal core transformers, our newest technology, dis- ANSI/IEEE standards. Our transformers are produced in a
tribution network losses could be reduced up to 70 percent. virtually connected global network of 14 factories. A common
These energy savings would ultimately mean lower operating technology platform comprising the best practices and sys-
costs and reduced environmental impact. tems is deployed within this network to ensure a replicable,
reliable product in terms of quality and performance.
As an added performance and environmental enhancement,
our low-loss transformers can be specified with natural ester, Concurrent with its leadership position, ABB is committed to
high temperature and biodegradable insulation liquid. ABB develop all its products to meet ever increasing environmen-
transformers with natural ester fluid offer the optimum combi- tal and higher efficiency requirements. As such, ABB takes
nation of performance and safety. into account the entire life cycle (cradle to grave), resulting
in the most environmentally friendly products, systems and
Let ABB be your partner in developing all of your future distribu- solutions possible.
tion transformer requirements. Simply put, ABBs transformers
are the ultimate solution in addressing total cost of ownership In line with this business philosophy, ABB has introduced
(TCO), environmental and safety issues, and energy efficiency. a green transformer portfolio for distribution transformers.
In addition to ABBs existing low loss, high efficiency trans-
Sustainability formers, we have introduced new technology products which
There are myriad definitions for sustainability but most offer even more energy savings, including liquid-filled amor-
acknowledge the responsibility that we all have in balancing phous metal (AM) transformers and biodegradable, high fire
the economic needs of society with social and environmen- point natural ester fluid.
tal impact. As the world population will most likely reach
between six and nine billion by 2050, we need to find ways The ABB green distribution transformer program
to consume the Earths resources at a rate by which they can The ABB green transformer program offers a modularized
be replenished. approach for product selection. The design features and options
available are:
Energy conservation and CO2 emission reduction need to be Copper or aluminum windings, with paper or enamel insula-
a focus for environmental sustainability. Globally, CO2 emis- tion
sions into the atmosphere are reaching 30 billion tons a year Step-lap stacked cores or wound cores
with concentrations having increased 140 percent since the Grain oriented core steel, ranging from M5 to domain re-
preindustrial revolution. fined, and amorphous metal for the ultimate in low losses
A variety of insulating liquids including mineral oil, silicone
As our demand and cost for electrical energy grows with the oil, synthetic ester-based fluids, and natural ester-based
world population, CO2 emission will also be on the increase. fluid with improved temperature performance and oxida-
So, finding ways to increase the efficiency of our electrical inf- tion stability
rastructure is an important factor towards reducing emissions Hermetically sealed or conservator type tanks, with cor-
and costs. Higher efficiency in the form of reduced losses can rugated fin walls or radiators
lead to avoided cost of generating additional electricity while Surface treatments, with water based or powder painting in
lowering total ownership cost of the electrical infrastructure. different RAL colors, or hot dip galvanization for aggressive
environmental conditions

2 Green distribution transformer program


Reducing operating costs without compromising efficiency

Supported by ABBs leading and extensive global transformer Lowering total cost of ownership
R&D base plus highly flexible design tools, this approach will In light of global climate concerns, many users agree that low
facilitate a high speed customization to meet desired custo- loss transformers should be chosen on criteria other than
mer criteria and requirements. Ultimately, products selected pure short term profitability aspects. When purchasing trans-
from the above modules will provide ABB customers with high formers, ABB recommends the use of total cost of ownership
efficiency and environmentally friendly solutions. (TCO) which considers the future operating costs of a unit
over its lifetime, brought back into present day cost and then
Increased transformer efficiency added to its total purchase price.
A testament to the importance of energy saving programs and
energy efficiency requirements is present in several wides- In calculating total ownership of cost (TOC), the losses are
pread global and local initiatives. evaluated by their financial impact, capitalized for an expec-
ted payback period for the transformer.
Examples of mandates or standards requiring high efficiencies
in distribution transformers are: US Department of Energys
mandated National Efficiency Standard, Australias Hi efficien-
cy 2010, Indias 4 and 5 Star programs, Chinas NX-1 stan- Ct = Transformer purchase price
dard, and the AkA0 standard in Europe. A = Assessed financial value (e.g., USD/W), or
capitalization factor, for no-load loss
Efficiency (percent) is a measure of how well a device con- B = Assessed financial value (e.g., USD/W), or
verts input energy into useful output - be it electrical power, capitalization factor, for load loss
mechanical work, or heat. Distribution class transformers have P0 = No-load Loss
efficiencies well above 90percent. P k = Load Loss

The efficiency of a distribution transformer increases with a The optimal selection would be the design with the lowest TCO
reduction in its load and losses. The transformer load losses as calculated previous. Simply put, the customer/user will ob-
decrease with the load, while no-load losses are a constant, tain a practical balance between investment and reward.
independent of the load. Since most transformers are rated
to handle peak loads which only happen at certain intervals TCO provides the true economics in evaluating a
during the day, distribution transformers can remain lightly transformer purchase.
loaded for a significant portion of the day. So, specifying the With low loss, high efficiency transformers, the higher material
lowest no-load loss possible reduces energy consumption, cost typically requires a higher first cost. However, this will be
goes hand-in-hand with increased efficiency, and can increase compensated by reduced running costs from lower losses.
revenue for a power producer. Beyond a certain time, the lower losses will give a net financial
saving from reduced energy costs. If higher loss transform-
ers are replaced with new low loss transformers, this saving
becomes even greater. Furthermore, lower losses result in
cost avoidance derived from elimination or deferral of extra
generation and transmission capacity additions.

Green distribution transformer program 3


Reducing operating costs without compromising efciency

TCO provides the true economics in evaluating a Application example transformers in wind farms
transformer purchase Energy is produced from the turbines in a wind farm for only
With low loss, high efciency transformers, the higher material short periods throughout the day. Therefore, it is desirable to
cost typically requires a higher rst cost. However, this will be minimize no-load losses in wind farm applications.
compensated by reduced running costs from lower losses.
Beyond a certain time, the lower losses will give a net nancial The advantage of AM transformers in such applications is
saving from reduced energy costs. If higher loss transform- evident in Figure 2. Here, TCO results for 1,750 kVA liquid-im-
ers are replaced with new low loss transformers, this saving mersed, RGO and AM transformers are compared for a wind
becomes even greater. Furthermore, lower losses result in farm, where A = 8 USD/W and B = 2 USD/W.
cost avoidance derived from elimination or deferral of extra
generation and transmission capacity additions.

Application example transformers for utilities


Figure 1. compares the TCO of liquid-immersed 1,000 kVA
transformers having conventional, regular grain oriented (RGO)
and AM cores, wherein the loss capitalization factors are: A
= 10 USD/W and B = 2 USD/W. The various components
comprising the TCO are individually highlighted. Although rst
costs of amorphous transformers may be slightly higher, they
are often the preferred choice if TCO is considered.

Liquid-immersed transformer

RGO
Amorphous
Metal
0% 50% 100% 150% 200% 250%

A = 10 USD/W; B = 2 USD/W

Purchase price Capitalized loss cost TCO Savings


Figure 1.

1,750 kVA wind farm transformers

RGO
Amorphous
Metal
0 20000 4000 0 6 0000

TCO (USD)
Figure 2.

4 Green distribution transformer program


ABB has the optimum solution for a greener world

Amorphous Metal Distribution Transformers (AMDT) The much lower losses of the AMDT result in significant ener-
from ABB represent the ultra-low loss design solution, gy and monetary savings over the lifetime of the transformer.
delivering the highest efficiencies. They are designed with
a unique alloy whose structure of metal atoms occurs Natural ester based dielectric insulating fluid is combining
in a random pattern and is used in lieu of conventional environmental friendliness, superior fire resistance
Regular Grain Oriented (RGO) silicon steel. RGO has an and high temperature stability with excellent dielectric
organized grain structure with much higher resistance to characteristics. It is made from vegetable-based oil,
magnetization cycles, which leads to higher core losses. made out of natural seeds, with more than 90 percent
biodegradability, according to CEC L-33-A test method. It
Amorphous metal A technological advantage has a fire point over 300C and the unique ability to build
Amorphous metal (AM) enables a significant reduction in less tank pressure during high-energy arc faults. Its water
no-load losses as compared to RGO, up to 70 percent lower saturation limit is also much higher than that of mineral oil
as noted below for representative liquid-filled transformer without affecting its dielectric strength. Natural ester fluid
designs. allows higher hotspot temperatures without reducing the
insulation system lifetime thank s to its greater ability to
hold moisture
No-Load No-Load
Losses (W) Losses Natural ester-based dielectric insulating fluid
Rating Regular Grain Amorphous Loss Mineral-based oils have been the dielectric insulating medium
(kVA) Oriented Metal Reduction of choice for transformers for more than 100 years.
Single-phase Natural ester fluid is the alternative solution addressing the
15 55 20 64% major drawbacks of petroleum-based products, i.e., high
25 65 30 54% combustibility and pollution. At the same time, it provides
50 105 35 67% more reliability to your equipment.
75 155 55 65%
100 200 75 63% Environmental, safety and operational advantages
167 235 95 60% Natural ester fluid is more than 90 percent biodegradable,
Three-phase according to CEC L-33-A test method. Subject to environ-
300 505 200 60% mental regulations, natural ester fluid spills can be dispo-
500 725 220 70% sed through normal means and not treated as hazardous
750 1125 355 68% waste
1500 2170 725 67% With a fire point above 300C, natural ester fluid is listed
2500 2750 745 73% as a less flammable dielectric fluid by FM Global and UL,
Comparison with lowest no-load loss specifications (Ao) in and has a K2 fire hazard classification (IEC 61100)
IEC EN50464-1 with some three phase AM designs With less pressure build-up during high-energy arc faults,
100 145 75 48% natural ester fluid reduces risk of transformer explosion
250 300 110 63% and fire. It is therefore suitable for indoor applications and
400 430 170 60% outdoor areas of heightened safety sensitivity
800 650 330 49 The greater ability of natural ester to hold moisture allows
impregnated paper to experience a much lower aging rate.
Studies have also shown benefits from AM in the presence A natural ester fluid-filled transformer can consequently
of harmonics or integer multiples of the power frequency operate at higher hotspot temperatures while maintaining
(50 or 60 Hz). When non-linear loads (e.g. rotating machines) the same life expectancy as a standard mineral oil-filled
are present, they cause the current and voltage waveforms to unit, hence increasing its overload capacity
distort, causing harmonics which increase losses in the trans-
former and reduce power quality. However, these harmonics With natural ester fluid, ABB aims at offering a complete and
losses are reduced in an AMDT. This translates into operating sustainable solution for transformer applications by combining
savings across a variety of resistive and inductive loads. environmental friendliness (high biodegradability), safety (su-
perior fire resistance) and reliability (high overload capacity).

Green distribution transformer program 5


ABB your sustainability partner

ABBs commitment to a greener future Financial advantages based on optimized total


The ABB value proposition cost of ownership (TCO)
Environmentally friendly Due to lower TCO, savings can be realized in as little as
The green distribution transformer program three-five years
Reduce no-load losses 40-70 percent, thus reducing TCO Lower losses result in cost avoidance derived from eli-
and CO2 emissions mination or deferral of extra generation and transmission
For each GW saved, annual reduction of five million tons of capacity
CO2 emissions Increased reliability and longer life time
One 1,000 kVA unit can save seven tons of CO2 annually
Total solution for high efficiency transformers, new and ABB has the optimum solution
conventional technologies Amorphous transformers with natural ester fluid is an
environmentally optimized solution
Reliability, quality, and customized solutions Amorphous metal lowers ownership cost across entire net-
Lower losses generate less heat, thus reducing liquid capa- work from generation to transmission and distribution
city and cooling needs Amorphous metal and natural ester fluid help reduce green
Tested to exceed applicable standards including short house gases along with pollutants
circuit tests Natural ester fluid is engineered to be environmentally
Flexible design tools integrating conventional technology friendly
and new solutions in order to optimize a solution based on Offers you the lowest Life Cycle Assessment (LCA) value
customers demand and requirement for a distribution transformer
Combining the global ABB experience in high tech solu-
tions for conventional technology with new solutions and
technologies Combining energy efficiency,
safety and environmental
friendliness ABB has the
complete sustainability solution
for liquid-filled distribution
transformers.

6 Green distribution transformer program


Support for a greener future

Calculation of transformer efciency


When calculating efciency, one must know the transformer In these equations, C d (USD/W), the demand charge, is the
rating (kVA r), loading (kVA l), power factor (PF), and transfor- cost for generation capacity extension (utilities) or the monthly
mer losses. Transformer losses are made up of load (P k) and rate of peak power (commercial and industrial consumers), C e
no-load (P o) losses. Load or winding losses vary directly by (USD/Wh) is the cost of energy and is customer, application,
the square of the load factor (L), meaning losses increase as and standards dependant, h is the annual utilization hours of
transformer loading increases. No-load or core losses remain the transformer (full year = 8,760 hours), and F c is the present
constant regardless of the load. Furthermore, no-load losses value factor, calculated for n years using a discount rate i.
can be a signicant percentage of total losses when a trans-
former is lightly loaded. Cost of emissions
There currently is no universal way to account for the cost of
emissions in TCO as they are very much dependant on the
regulatory and political climate. Factors that would be used
need to take into account not only economic but also social
impact. The latter is most challenging to quantify.

One can account economical costs for emissions within the


TCO calculation by adding emission costs (C em) to the cost
of energy (C e) for a total cost of energy (C E), which takes the
Calculation of Total Cost of Ownership (TCO) place of C e in the previous equations.
In the following, USD is used for illustrative purposes.
(USD/Wh)

(USD/Wh)
where Ct (USD) is the transformer purchase price, and A and B
are the capitalization factors for no-load loss (Po) and load loss where E p (tons/Wh) characterizes total emissions, calculated
(Pk), respectively, expressed in (USD/W). There are various meth- from the known quantity of emissions for each of the pollut-
d, ants while producing a certain amount of electricity, and E c
(USD/ton) is the market value for the pollutants.

(USD/W) ABB recommends a periodic review of the A and B factors.


Other factors for such a review would be: the cost of energy
(USD/W) (Ce and Cem); the effective loading (L); and, the discount rate (i).

Green distribution transformer program 7


Contact us

1LAB000195-A
Note:
ABB Ltd. We reserve the right to make technical changes
Affolternstrasse 44 or modify the contents of this document without
P.O. Box 8131 prior notice. With regard to purchase orders, the
8050 Zurich, Switzerland agreed particulars shall prevail. ABB does not
accept any responsibility whatsoever for potential
www.abb.com/transformers errors or possible lack of information in this docu-
ment. We reserve all rights in this document and
in the subject matter and illustrations contained
therein. Any reproduction in whole or in parts is
forbidden without ABBs prior written consent.

Copyright 2015 ABB.


All rights reserved.

Green-R-Pad is a registered trademark of


ABB, Inc.

You might also like