You are on page 1of 2

Trafficguard UR* constructive solutions

Skid resistant, flexible, waterproof protection flooring


system

Uses Instructions for use

Trafficguard UR is a modified polyurethane-based traffic deck Surface Preparation


system designed to provide an added level of protection to,
New concrete surfaces should have reached 80% of their
new and existing, heavily trafficked areas such as:
intended physical properties - generally only achieved after a
! Car parks minimum curing period of 28 days. Existing concrete surfaces
must be prepared to provide a clean, sound substrate.
! Industrial manufacturing units
Surfaces should be clean and dry with open capillary, free
! Warehouses
from laitance, oil & grease, curing compounds or other surface
contaminants which may prevent full and proper adhesion of
Advantages
the primer. All blowholes, and other surface undulations
! Flexible and tear resistant greater than 1 mm in depth, should be repaired using
Nitomortar FC(B)*.
! Waterproof
Temperature of the substrate during application must be
! Seamless
between 5C and 40C.
! Rapid application, reliable and safe
Priming

Description Apply Trafficguard UR Primer to the prepared surface at a wet


film thickness of 200 microns.
Trafficguard UR is a multi-layer deck protection system
comprising a primer, flexible & waterproof base coat and UV Whilst Trafficguard UR Primer is still wet, seed with Fosroc
resistant wearing course. All components are applied in the Anti Slip Grain No. 3 at a rate of 0.4 kg / m2 and allow to cure for
liquid phase and react chemically to form a tough, flexible, 24 hours.
waterproof, protective surface.
Application
Trafficguard UR is available in a range of 3 standard colours:
Base Coat
Silver Grey, Sage Green or Brick Red.
Apply Trafficguard UR Base Coat to the primed surface at a
Properties wet film thickness of 750 microns. For best results the
Trafficguard UR Base Coat should be applied with a notched
Basecoat
trowel or squeegee.
Elongation (ASTM D412) : >100%
Tensile Strength (ASTM D412) : 6.0 N/mm Whilst the base coat is still wet apply Fosroc Anti Slip Grain
Tear Resistance (ASTM D624) : 26.0 N/mm No. 1200 at a rate of 0.4 kg / m2. Allow to cure for 12 hours
Shore A Hardness (ASTM D2240) : 80 - 86 prior to applying the wear course.

Wearcourse Wear Course


Weathering (30 days) : No change in Apply Trafficguard UR Wear Course to the base coat at a wet
(ASTM G53) original appearance film thickness of 140 microns. Allow to cure for 24 hours prior
Corrosion Resistance : No change in to trafficking.
(ASTMB117) original appearance
Humidity Resistance : No change in Cleaning
(water Fog exposure) original appearance Tools and equipment should be cleaned with immediately
after use with Fosroc Solvent 102*.
Trafficguard UR*
Trafficguard UR*

Estimating Precautions

Supply Health and safety


Trafficguard UR Primer : 4 litre packs
Trafficguard UR Primer, loose cans and wear course and
Trafficguard UR Base Coat : 8 litre packs
Fosroc Solvent 102 should not come in contact with skin or
Trafficguard UR Wear Course : 20 litre packs
eyes, nor should they be swallowed. Avoid inhalation of
Antislip Grains No. 1200, 3 : 20 kg bags
vapours and ensure adequate ventilation.
Coverage
Some people are sensitive to resins, hardeners and solvents.
Trafficguard UR Primer : 5.0 m2/litre
Wear suitable protective clothing, gloves and eye/face
Trafficguard UR Base Coat : 1.3 m2/litre
protection. Barrier creams such as Kerodex Antisolvent or
Trafficguard UR Wear Course : 7.0 m2/litre
Rozalex Antipaint provide additional skin protection.
Antislip Grains No. 1200, 3 : 0.4 kg / m
Should accidental skin contact occur, remove immediately
Note: The above coverage rates are given for guidance only
with a resin removing cream such as Kerocleanse Standard
as actual quantities used will vary depending upon
Grade Skin Cleanser or Rozaklens Industrial Skin Cleanser,
the nature of substrate and conditions on site.
followed by washing with soap and water - do not use solvent.

Storage The use of goggles is recommended, in case of accidental


eye contamination, rinse immediately with plenty of water
Shelf life
and seek medical advice.
When stored in warehouse conditions at less than 25C,
If swallowed seek medical attention immediately - do not
Trafficguard UR will have a shelf life of 12 months.
induce vomiting.

Technical Support Fire

Fosroc offers a full technical support package to specifiers, Fosroc Solvent 102 and Trafficguard UR Primer are
end users and contractors, as well as on-site assistance in flammable. Do not use near a naked flame.
locations all over the world.
Flash points
Fosroc Solvent 102 : 33C
Limitations
Trafficguard UR Primer : 59C
- Do not proceed with application if precipitation is imminent,
temperatures are expected to drop below 7C within 24
hours of application.

- Trafficguard UR should not be applied onto substrate known


to suffer from rising dampness, having R.H. greater than
75% as measured in accordance with BS 8203 Appendix A
or having moisture content greater than 5% as measured
by a Hammond concrete/mortar moisture tester (type COCO).
* Denotes the trademark of Fosroc International Limited
- Do not proceed with application if an osmotic condition is

known or is suspected to exist. See separate data sheet
Important note
Fosroc products are guaranteed against defective materials and manufacture and are sold subject to its standard
Conditions for the Supply of Goods and Service. All Fosroc datasheets are updated on a regular basis. It is the users
responsibility to obtain the recent version. Refer to www.fosroc.com.

Head Office
Al Gurg Fosroc telephone: (+9714) 2039699 fax: (+9714) 2859649 email: agf@fosroc.com
LLC Regional offices
Abu Dhabi, Al Gurg Fosroc telephone: 673 1779 fax: 673 1449 email: abudhabi@fosroc.com
Post Box 657, Dubai Bahrain, YBA Kanoo telephone: 17735454 fax: 17732828 email: bahrain@fosroc.com
United Arab Emirates Kuwait, Boodai telephone: 4817618 fax: 4832124 email: kuwait@fosroc.com
Oman, Al Amana telephone: 24815080 fax: 24817554 email: oman@fosroc.com

www.fosroc.com
Qatar, Tadmur telephone: 4500607 fax: 4500543 email: qatar@fosroc.com

UAE/0291/06/H

You might also like