Specifications listed below are typical at 25 C unless otherwise noted. Refer to the NI USB-621x User Manual for more
information about USB-621x devices.
Caution The input/output ports of this device are not protected for electromagnetic interference due to functional
reasons. As a result, this device may experience reduced measurement accuracy or other temporary performance
degradation when connected cables are routed in an environment with radiated or conducted radio frequency
electromagnetic interference.
To ensure that this device functions within specifications in its operational electromagnetic environment and to limit radiated
emissions, care should be taken in the selection, design, and installation of measurement probes and cables.
Franais Deutsch
ni.com/manuals
Analog Input
Number of channels Input range.......................................10 V, 5 V,
USB-6210/6211/6212/ 1 V, 0.2 V
6215/6216................................... 8 differential or
Maximum working voltage for analog inputs
16 single ended
(signal + common mode).................10.4 V of AI GND
USB-6218................................... 16 differential or
32 single ended CMRR (DC to 60 Hz) .....................100 dB
USB-6210/6211/6215/6218
90 ppm of step (6 LSB)......4 s convert interval
30 ppm of step (2 LSB)......5 s convert interval USB-6212/6216
Settling Error Versus Time for Different Source Impedances
15 ppm of step (1 LSB)......7 s convert interval
10 k
USB-6212/6216
Error (ppm of Step Size)
10
1
1 10 100
Time (s)
AI <0..31> CMRR
140
120
CMRR (dB)
100
80
60
40
60 100 1k 10 k 100 k
Frequency (Hz)
Timing resolution............................ 50 ns
Glitch energy
Magnitude................................... 100 mV
Duration...................................... 2.6 s
1 Absolute accuracy at full scale on the analog input channels is determined using the following assumptions:
TempChangeFromLastExternalCal = 10 C
TempChangeFromLastInternalCal = 1 C
number_of_readings = 100
CoverageFactor = 3
For example, on the 10 V range, the absolute accuracy at full scale is as follows:
GainError = 75 ppm + 7.3 ppm 1 + 5 ppm 10 GainError = 132 ppm
OffsetError = 20 ppm + 34 ppm 1 + 76 ppm OffsetError = 130 ppm
229 V 3
NoiseUncertainty = -------------------------- NoiseUncertainty = 68.7 V
100
AbsoluteAccuracy = 10 V (GainError) + 10 V (OffsetError) + NoiseUncertainty AbsoluteAccuracy = 2,690 V
2 Sensitivity is the smallest voltage change that can be detected. It is a function of noise.
Accuracies listed are valid for up to one year from the device external calibration.
ni.com
AI Absolute Accuracy Table (USB-6212/6216)
National Instruments Corporation
1 Absolute accuracy at full scale on the analog input channels is determined using the following assumptions:
TempChangeFromLastExternalCal = 10 C
TempChangeFromLastInternalCal = 1 C
number_of_readings = 100
CoverageFactor = 3
For example, on the 10 V range, the absolute accuracy at full scale is as follows:
GainError = 75 ppm + 7.3 ppm 1 + 5 ppm 10 GainError = 132 ppm
OffsetError = 20 ppm + 34 ppm 1 + 76 ppm OffsetError = 130 ppm
295 V 3
NoiseUncertainty = -------------------------- NoiseUncertainty = 88.5 V
100
NI USB-621x Specifications
Accuracies listed are valid for up to one year from the device external calibration.
NI USB-621x Specifications AO Absolute Accuracy Table
Nominal Range Residual Absolute
Residual Gain Offset Error Offset Tempco INL Error Accuracy at
Positive Negative Error (ppm of Gain Tempco Reference (ppm of (ppm of (ppm of Full Scale1
Full Scale Full Scale Reading) (ppm/C) Tempco Range) Range/C) Range) (V)
10 10 90 11 5 60 12 128 3,512
1Absolute Accuracy at full scale numbers is valid immediately following internal calibration and assumes the device is operating within 10 C of the last external calibration.
Accuracies listed are valid for up to one year from the device external calibration.
1 Stresses beyond those listed under Input voltage protection may cause permanent damage to the device.
25
Position measurements ................... X1, X2, X4 quadrature
30 encoding with
35 Channel Z reloading;
0 C; Vdd = 5.5 V
40 two-pulse encoding
45
Output applications ......................... Pulse, pulse train with
50
2 3 4 5 6 dynamic updates,
Voh (V) frequency division,
equivalent time sampling
0 C; Vdd = 5.5 V
20 Aux, A, B, Z, Up_Down
Frequency Generator
Number of channels ........................ 1
Divisors........................................... 1 to 16
I/O connectors
Power Limits USB-6210/6211/6215 .................Two 16-position
+5 V terminal as output2 combicon
Voltage ....................................... 4.6 to 5.2 V USB-6212/6216/6218
Current (internally limited) ........ 50 mA max, shared Screw Terminal...........................Four 16-position
with digital outputs combicon
+5 V terminal as input2 USB-6212/6216
Mass Termination .......................One 68-pin SCSI
Voltage ....................................... 4.75 to 5.35 V
USB-6212/6216/6218 BNC........19 BNCs and
Current........................................ 350 mA max,
26 screw terminals
self-resetting fuse
USB connector ................................Series B receptacle
Caution Do not exceed 16 mA per DIO pin.
Screw terminal wiring .....................16 to 28 AWG
Protection.................................... 10 V Torque for screw terminals .............0.220.25 N m
(2.02.2 lb in.)
1 If you are using a USB M Series device in Full-Speed mode, device performance will be lower and you will not be able to
achieve maximum sampling/update rates.
2 USB-621x Screw Terminal/BNC devices have a self-resetting fuse that opens when current exceeds this specification.
USB-621x Mass Termination devices have a user-replaceable socketed fuse that opens when current exceeds this specification.
Refer to the NI USB-621x User Manual for information about fuse replacement.
Storage temperature.........................20 to 70 C
Isolated Front End USB Connector
Humidity..........................................10 to 90% RH,
noncondensing Va AI x/AO x
Isolation Barrier
Maximum Working Voltage1 Ve
USB-6210/6211/6212 Rated Voltage Bus
Channel-to-earth ground..................11 V,
Vd
Measurement Category I
Analog channel to AI GND/AO GND Note For UL and other safety certifications, refer
(in Figure 1, Va Vc)...................11 V, to the product label or the Online Product
Measurement Category I3 Certification section.
1 Maximum working voltage refers to the signal voltage plus the common-mode voltage.
2 In Figure 1, Va Vd, Vb Vd, and Vc Vd.
3 Measurement Category I is for measurements performed on circuits not directly connected to the electrical distribution system
referred to as MAINS voltage. MAINS is a hazardous live electrical supply system that powers equipment. This category is
for measurements of voltages from specially protected secondary circuits. Such voltage measurements include signal levels,
special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltage sources, and electronics.
CE Compliance
This product meets the essential requirements of applicable
European Directives as follows:
2006/95/EC; Low-Voltage Directive (safety)
2004/108/EC; Electromagnetic Compatibility Directive
(EMC)
Environmental Management
NI is committed to designing and manufacturing products in
an environmentally responsible manner. NI recognizes that
eliminating certain hazardous substances from our products is
beneficial to the environment and to NI customers.
RoHS
National Instruments
(RoHS)
National Instruments RoHS
ni.com/environment/rohs_china
(For information about China RoHS compliance,
go to ni.com/environment/rohs_china.)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
PFI 0/P0.0 (In)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
PFI 1/P0.1 (In)
PFI 2/P0.2 (In) PFI 1/P0.1 (In)
PFI 3/P0.3 (In) PFI 2/P0.2 (In)
D GND PFI 3/P0.3 (In)
PFI 4/P1.0 (Out) D GND
PFI 5/P1.1 (Out) PFI 4/P1.0 (Out)
PFI 6/P1.2 (Out) PFI 5/P1.1 (Out)
PFI 7/P1.3 (Out) PFI 6/P1.2 (Out)
+5 V PFI 7/P1.3 (Out)
D GND +5 V
NC D GND
NC AO 0
RESERVED AO 1
AI 0 AO GND
AI 8 AI 0
AI 8
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
AI 1
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
AI 9 AI 1
AI 2 AI 9
AI 10 AI 2
AI 3 AI 10
AI 11 AI 3
AI SENSE AI 11
AI 4 AI SENSE
AI 12 AI 4
AI 5 AI 12
AI 13 AI 5
AI GND AI 13
AI 6 AI GND
AI 14 AI 6
AI 7 AI 14
AI 15 AI 7
AI 15
NC = No Connect
AO 1
PFI 1/P1.1 PFI 9/P2.1 20 54
NC AO GND
PFI 2/P1.2 PFI 10/P2.2
PFI 3/P1.3 PFI 11/P2.3 P0.4 19 53 D GND
D GND D GND D GND 18 52 P0.0
PFI 4/P1.4 PFI 12/P2.4 P0.1 17 51 P0.5
PFI 5/P1.5 PFI 13/P2.5
PFI 6/P1.6 PFI 14/P2.6 P0.6 16 50 D GND
PFI 7/P1.7 PFI 15/P2.7 D GND 15 49 P0.2
+5 V +5 V +5 V 14 48 P0.7
D GND D GND
AO 0 P0.0 D GND 13 47 P0.3
AO 1 P0.1 D GND 12 46 PFI 11/P2.3
AO GND P0.2 PFI 0/P1.0 11 45 PFI 10/P2.2
AI 0 P0.3
AI 8 D GND PFI 1/P1.1 10 44 D GND
D GND 9 43 PFI 2/P1.2
+5 V 8 42 PFI 3/P1.3
D GND 7 41 PFI 4/P1.4
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49
AI 1 D GND
AI 9 P0.4 PFI 5/P1.5 6 40 PFI 13/P2.5
AI 2 P0.5
PFI 6/P1.6 5 39 PFI 15/P2.7
AI 10 P0.6
AI 3 P0.7 D GND 4 38 PFI 7/P1.7
AI 11 D GND PFI 9/P2.1 3 37 PFI 8/P2.0
AI SENSE P0.8
AI 4 P0.9
PFI 12/P2.4 2 36 D GND
AI 12 P0.10 PFI 14/P2.6 1 35 D GND
AI 5 P0.11
AI 13 D GND
AI GND P0.12
AI 6 P0.13 NC = No Connect
AI 14 P0.14
AI 7 P0.15
AI 15 D GND
TERMINAL 34 TERMINAL 68
TERMINAL 1 TERMINAL 35
Figure 4. USB-6212/6216 Screw Terminal Pinout Figure 5. USB-6212/6216 Mass Termination Pinout
AI GND
USB-621x Device
AI x +
+
AI x
GS
Ground- FS
Referenced
Source
0.1 F 5 k
AI GND
NI USB-6212/6216 USB-621x Device
64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49
AI 1 AI 17
AI 9 AI 25
AI 2 AI 18
AI 10 AI 26
AI 3 AI 19
AI 11 AI 27
AI SENSE AI GND
AI 4 AI 20
AI 12 AI 28
AI 5 AI 21
AI 13 AI 29
AI GND AI GND
AI 6 AI 22
AI 14 AI 30
AI 7 AI 23
AI 15 AI 31
NC = No Connect
AI GND
USB-621x Device
AI x +
+
AI x
GS
Ground- FS
Referenced
Source
0.1 F 5 k
AI GND
NI USB-6218 USB-621x Device
National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation.
Refer to the Terms of Use section on ni.com/legal for more information about National
Instruments trademarks. Other product and company names mentioned herein are trademarks or trade
names of their respective companies. For patents covering National Instruments products/technology,
refer to the appropriate location: HelpPatents in your software, the patents.txt file on your
media, or the National Instruments Patent Notice at ni.com/patents.