You are on page 1of 1

CALIBRATION REPORT

CALIPER SHOP CALIBRATION


Tool Name: MSFL - 11545819 Reference Calibration Date: 15-May-17 10:53:00
Engineer: JHON SANTOS Calibration Date: 15-May-17 10:57:20

Software Version: WL INSITE R5.2.3 (Build 2) Calibration Version: 1

CALIBRATION RINGS AND INTERNAL


Current Reading Calibrated
Measurement Change
(Previous Coeff.) (New Coeff.)
RING DIAMETER:
Ring #1 (in) 6.59 6.50 0.0900
Ring #2 (in) 15.00 15.00 0.0000
HI/LO INTERNAL:
Lo Internal (in) 6.59 6.50 0.0900
Hi Internal (in) 6.59 6.50 0.0900
TOOL VALUES:
Ring #1 936.044
Ring #2 1665.116
Lo Internal 936.000
Hi Internal 935.695
Gain 0.01166
Offset -4.4130

CALIBRATION SUMMARY

Sensor Shop Field Post Difference Tolerance Units


MSFL-11545819
Caliper Lo. Internal 6.50 ----------- ----------- 0.00 +/- xxxx in
Caliper Hi. Internal 6.50 ----------- ----------- 0.00 +/- xxxx in

Data: System\Calibrations\ Date: 25-May-17 11:13:39