Product Information

ISO - TP
LOW VOLTAGE METRIC INSULATORS

 Insulators:
The Low voltage insulators are mainly used to fix the active copper bar conductors or to support
earthing bars.

 Technical data:

Working temperature -40C up to 130C


Polyamide material reinforced with glass fibre,
Halogen free
Zinc plated steel inserts, threaded to ISO standard
Great stability of electrical and mechanical parameters
Self-extinguishing: UL 94 VO / Glow wire test 960C
IEC Voltage rating: see table
UL voltage rating: 1500 V AC /DC

 Certificates:

CE Conformity
ROHS 2002/95/EC Compliance
IEC 60439.1 & 61439.1 compliance
GOST Certificate (Russian territory)
For Canadian and US territory: UL Recognized in E125470 and evaluated for dielectric
withstand rating of 1500 V AC/DC

CADDY. CADWELD . CRITEC. ERICO. ERIFLEX. ERITECH. LENTON.


www.erico.com LOW VOLTAGE INSULATORS ISO-M
1/6 - P_I_ISO_TP_M_v13_EN.doc
Product Information

H Ch F h1 D P
Part No Description
(mm) (mm) (mm) (mm) (mm) (mm)
548400 ISO TP 15M4 15 14 M4 X 0,7 4 12 16 50 0,005 kg
548410 ISO TP 20M4 20 17 M4 X 0,7 4 15 20 50 0,008 kg
548420 ISO TP 20M6 20 17 M6 X 1 6 15 20 50 0,012 kg
548700 ISO TP 25M5 25 19 M5 X 0,8 6 18 20 50 0,016 kg
548430 ISO TP 25M6 25 19 M6 X 1 6 18 20 50 0,016 kg
548440 ISO TP 30M6 30 30 M6 X 1 8 26 34 25 0,034 kg
548450 ISO TP 30M8 30 30 M8 X 1,25 8 26 34 25 0,046 kg
548451 ISO TP 30M10 30 30 M10 X 1,5 10 26 34 25 0,041 kg
548470 ISO TP 35M6L 35 41 M6 X 1 8 34 46 25 0,062 kg
548480 ISO TP 35M8 35 41 M8 X 1,25 8 34 46 25 0,074 kg
548490 ISO TP 35M10* 35 41 M10 X 1,5 10 34 46 25 0,092 kg
548500 ISO TP 40M6 40 46 M6 X 1 9 40 53 25 0,098 kg
548510 ISO TP 40M8 40 46 M8 X 1,25 8 40 53 25 0,104 kg
548520 ISO TP 40M10 40 46 M10 X 1,5 10 40 53 25 0,102 kg
548511 ISO TP 40M12 40 46 M12 X 1,75 14,5 40 53 25 0,102 kg
548530 ISO TP 45M6 45 41 M6 X 1 9 34 47 25 0,104 kg
548540 ISO TP 45M8 45 41 M8 X 1,25 15 34 47 25 0,136 kg
548550 ISO TP 45M8L 45 50 M8 X 1,25 15 41 57 25 0,132 kg
548560 ISO TP 45M10 45 50 M10 X 1,5 10 41 57 25 0,116 kg
548570 ISO TP 50M6 50 50 M6 X 1 9 41 57 25 0,152kg
548580 ISO TP 50M8 50 50 M8 X 1,25 15 41 57 25 0,148 kg
548590 ISO TP 50M10 50 50 M10 X 1,5 10 41 57 25 0,196 kg
548581 ISO TP 50M12 50 50 M12 X 1,75 14,5 41 57 25 0,190 kg
548600 ISO TP 60M8 60 55 M8 X 1,25 15 44 63 25 0,192 kg
548610 ISO TP 60M10 60 55 M10 X 1,5 10 44 63 25 0,380 kg
548601 ISO TP 60M12 60 55 M12 X 1,75 14,5 44 63 25 0,360kg
548602 ISO TP 60M16 60 55 M16 X 2 20 44 63 25 0,350kg
548609 ISO TP 70M10 70 65 M10 X 1,5 10 52 75 10 0,480kg
548620 ISO TP 70M12 70 65 M12 X 1,75 20 52 75 10 0,470 kg
548630 ISO TP 70M16 70 65 M16 X 2 20 52 75 10 0,374 kg

CADDY. CADWELD . CRITEC. ERICO. ERIFLEX. ERITECH. LENTON.


www.erico.com LOW VOLTAGE INSULATORS ISO-M
2/6 - P_I_ISO_TP_M_v13_EN.doc
Product Information

548629 ISO TP 75M10 75 65 M10 X 1,5 10 51 75 10 0,530 kg


548640 ISO TP 75M12 75 65 M12 X 1,75 20 51 75 10 0,470 kg
548650 ISO TP 75M16 75 65 M16 X 2 20 51 75 10 0,382 kg
548660 ISO TP 80M12 80 65 M12 X 1,75 20 52 75 10 0,510kg
548670 ISO TP 80M16 80 65 M16 X 2 20 52 75 10 0,404 kg
548680 ISO TP 100M12 100 65 M12 X 1,75 20 46 75 10 0,476 kg
548690 ISO TP 100M16 100 65 M16 X 2 20 46 75 10 0,508 kg

CADDY. CADWELD . CRITEC. ERICO. ERIFLEX. ERITECH. LENTON.


www.erico.com LOW VOLTAGE INSULATORS ISO-M
3/6 - P_I_ISO_TP_M_v13_EN.doc
Product Information

 Electrical and mechanical characteristics:


IEC Nominal voltage Mechanical
Part No Description Tensile Bending
Alternating Direct
strength strength
(V) (V)
(daN) (daN)
548400 ISO TP 15M4 500 V IEC/ 500 V IEC/ 150 100
548410 ISO TP 20M4 1000 V IEC/ 1500 V IEC 150 100
548420 ISO TP 20M6 1000 V IEC/ 1500 V IEC / 150 100
548700 ISO TP 25M5 1000 V IEC/ 1500 V IEC / 300 160
548430 ISO TP 25M6 1000 V IEC/ 1500 V IEC / 300 160
548440 ISO TP 30M6 1000 V IEC/ 1500 V UL 1500 V IEC / UL 600 300
548450 ISO TP 30M8 1000 V IEC/ 1500 V UL 1500 V IEC / UL 600 300
548451 ISO TP 30M10 1000 V IEC/ 1500 V UL 1500 V IEC / UL 600 300
548470 ISO TP 35M6L 1000 V IEC/ 1500 V UL 1500 V IEC / UL 1100 500
548480 ISO TP 35M8 1000 V IEC/ 1500 V UL 1500 V IEC / UL 1100 800
548490 ISO TP 35M10* 1000 V IEC/ 1500 V UL 1500 V IEC / UL 1100 800
548500 ISO TP 40M6 1000 V IEC/ 1500 V UL 1500 V IEC / UL 1100 800
548510 ISO TP 40M8 1000 V IEC/ 1500 V UL 1500 V IEC / UL 1100 800
548520 ISO TP 40M10 1000 V IEC/ 1500 V UL 1500 V IEC / UL 1100 450
548511 ISO TP 40M12 1000 V IEC/ 1500 V UL 1500 V IEC / UL 1100 450
548530 ISO TP 45M6 1000 V IEC/ 1500 V UL 1500 V IEC / UL 1100 650
548540 ISO TP 45M8 1000 V IEC/ 1500 V UL 1500 V IEC / UL 1100 650
548550 ISO TP 45M8L 1000 V IEC/ 1500 V UL 1500 V IEC / UL 1800 1000
548560 ISO TP 45M10 1000 V IEC/ 1500 V UL 1500 V IEC / UL 1800 700
548570 ISO TP 50M6 1000 V IEC/ 1500 V UL 1500 V IEC / UL 2000 700
548580 ISO TP 50M8 1000 V IEC/ 1500 V UL 1500 V IEC / UL 2000 1000
548590 ISO TP 50M10 1000 V IEC/ 1500 V UL 1500 V IEC / UL 2000 1000
548581 ISO TP 50M12 1000 V IEC/ 1500 V UL 1500 V IEC / UL 2000 1000
548600 ISO TP 60M8 1000 V IEC/ 1500 V UL 1500 V IEC / UL 2200 1000
548610 ISO TP 60M10 1000 V IEC/ 1500 V UL 1500 V IEC / UL 2200 1000
548601 ISO TP 60M12 1000 V IEC/ 1500 V UL 1500 V IEC / UL 2200 1000
548602 ISO TP 60M16 1000 V IEC/ 1500 V UL 1500 V IEC / UL 2200 1000
548609 ISO TP 70M10 1000 V IEC/ 1500 V UL 1500 V IEC / UL 2200 1000
548620 ISO TP 70M12 1000 V IEC/ 1500 V UL 1500 V IEC / UL 2500 1600
548630 ISO TP 70M16 1000 V IEC/ 1500 V UL 1500 V IEC / UL 2500 1600
548629 ISO TP 75M10 1000 V IEC/ 1500 V UL 1500 V IEC / UL 2200 1000
548640 ISO TP 75M12 1000 V IEC/ 1500 V UL 1500 V IEC / UL 3000 1600
548650 ISO TP 75M16 1000 V IEC/ 1500 V UL 1500 V IEC / UL 3000 1600
548660 ISO TP 80M12 1000 V IEC/ 1500 V UL 1500 V IEC / UL 3000 1600
548670 ISO TP 80M16 1000 V IEC/ 1500 V UL 1500 V IEC / UL 3000 1600
548680 ISO TP 100M12 1000 V IEC/ 1500 V UL 1500 V IEC / UL 3000 1000
548690 ISO TP 100M16 1000 V IEC/ 1500 V UL 1500 V IEC / UL 3000 1500

CADDY. CADWELD . CRITEC. ERICO. ERIFLEX. ERITECH. LENTON.


www.erico.com LOW VOLTAGE INSULATORS ISO-M
4/6 - P_I_ISO_TP_M_v13_EN.doc
Product Information

Part H Ch F1 h1 F2 H2 D P
Description
No (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm)
M10 X M16 X 0,45
541600 ISO TP 60F10M16 60 55 10 40 44 63 25
1,5 2 kg
M12 X M16 X 0,44
541601 ISO TP 60F12M16 60 55 14 40 44 63 25
1,75 2 kg
ISO TP 30 M8X M8X 0,05
542030 30 30 8 17 26 34 25
MM8X17/FM8X8 1,25 1,25 kg
ISO TP 40 M8X M8X 0,110
542050 40 46 8 17 40 53 25
MM8X17/FM8X8 1,25 1,25 kg
ISO TP 50 M8X M8X 0,150
542070 50 50 15 17 41 57 25
MM8X17/FM8X15 1,25 1,25 kg
ISO TP 60 M8X M8X 0,190
542080 60 55 15 17 44 63 25
MM8X17/FM8X15 1,25 1,25 kg
ISO TP 80 M8X M8X 0,350
542110 80 65 15 17 52 75 10
MM8X17/FM8X15 1,25 1,25 kg
ISO TP 100 M12 X M12 X 0;510
542120 100 65 20 20 46 75 10
MM12X25/FM12X20 1,75 1,75 kg

 Electrical and mechanical characteristics:

IEC Nominal voltage Mechanical


Part No Description Tensile Bending
Alternating Direct
strength strength
(V) (V)
(daN) (daN)
541600 ISO TP 60F10M16 1000 V IEC/ 1500 V UL 1500 V IEC / UL 2200 1000
541601 ISO TP 60F12M16 1000 V IEC/ 1500 V UL 1500 V IEC / UL 2200 1000
ISO TP 30
542030 1000 V IEC/ 1500 V UL 1500 V IEC / UL 600 300
MM8X17/FM8X8
ISO TP 40
542050 1000 V IEC/ 1500 V UL 1500 V IEC / UL 1100 650
MM8X17/FM8X8
ISO TP 50
542070 1000 V IEC/ 1500 V UL 1500 V IEC / UL 2000 1000
MM8X17/FM8X15
ISO TP 60
542080 1000 V IEC/ 1500 V UL 1500 V IEC / UL 2200 1000
MM8X17/FM8X15
ISO TP 80
542110 1000 V IEC/ 1500 V UL 1500 V IEC / UL 2200 1000
MM8X17/FM8X15
ISO TP 100
542120 1000 V IEC/ 1500 V UL 1500 V IEC / UL 3000 1000
MM12X25/FM12X20

CADDY. CADWELD . CRITEC. ERICO. ERIFLEX. ERITECH. LENTON.


www.erico.com LOW VOLTAGE INSULATORS ISO-M
5/6 - P_I_ISO_TP_M_v13_EN.doc
Product Information

 Recommended torques on the insulators *:

Torque
Sizes
N.m
M5 4
M6 6
M8 16
M10 33
M12 57
M16 109

* Values given for mechanical attachments, using flat washers, tightened with a torque wrench, without lubrication,
and with a screw penetration > 80% of h1 length.

CADDY. CADWELD . CRITEC. ERICO. ERIFLEX. ERITECH. LENTON.


www.erico.com LOW VOLTAGE INSULATORS ISO-M
6/6 - P_I_ISO_TP_M_v13_EN.doc