ZXT-120

(Z-Wave-to-AC IR Extender)

Firmware Version:

V1.0, V1.1, V1.2, V1.4

1
Table of Contents
Introduction .................................................... 3
Controller and Gateway Requirements ............ 4
Built-in IR code library .................................... 4
Glossary .......................................................... 5
ZXT-120 Operations ........................................ 6
Product Overview ............................................. 7
Z-Wave Remote Control ................................... 8
ZXT-120 Information ....................................... 9
Listening Mode Change .................................... 11
IR Code Selection ............................................ 12
IR Code Learning ............................................ 13
Reset ZXT-120 to factory default........................ 17
INSTALLATION ................................................ 18
MOUNTING THE ZXT-120 TO A WALL .................. 18
WIRELESS INFORMATION ............................... 21
MAINTENANCE................................................. 21
FREQUENTLY ASKED QUESTIONS .................... 21
Z-Wave Frequently Asked Questions ................... 21
TECHNICAL SPECIFICATIONS .......................... 23
CHECKING ACCESSORIES ................................ 28
FCC NOTICE .................................................... 28
WARNINGS ...................................................... 28
CAUTION ........................................................ 28
WARRANTY ..................................................... 29

2
Z-ExtenderTM ZXT-120
(Z-Wave-to-AC IR Extender)
Operating Instructions

Introduction
TheZXT120isaZWavetoIRextenderforairconditioner(AC),
(Figure1),itworkswithanyZWavecompliantgatewayorcontroller
bytranslatingZWaveThermostatCommandstoACIRcontrolcode.
UsercanselecttheIRcodefromthebuiltincodelibraryofZXT120,
oruselearningfunction,byusingZWaveConfigurationCommands
accordingtotheparametertable.ZXT120isalsowithbuiltin
temperaturesensorwhichallowsgatewayorcontrollertogetthe
currentroomtemperature.

Figure 1 ZXT-120

ZXT120canbeconfiguredaseitherFrequentlyListeningRouting
Slaves(FLiRS)orAlwaysListeningnodeafterexclusionprocess
(beforeinclusionprocess).

FLiRSnodetypeisforbatteryoperatedapplicationsanditwillenter
sleepmodefrequentlyinordertoconservebatteryconsumptionthat
canprovidetheflexibilityifthereisoutof5Vdcpowersource.Also,
usercanplacetheunitinanywhereathome.

AlwaysListeningnodetypeisfortheneedsoffastresponse
application.Itworkswith5Vdcpowersource.AlwaysListeningnode
canactasarepeater,whichwillretransmittheRFsignaltoensure
thatthesignalisreceivedbyitsintendeddestinationbyroutingthe
signalaroundobstacleandradiodeadspots.

ZXT120supportsNetworkWideInclusion(NWI)andExploreFrames.
ItalsosupportsZWavenetworkswithmultiplegatewaysand
controllers.LikeeveryZWaveaccessory,userwillneedtoincludethe

3
ZXT120intotheirZWavenetworkusingtheprimarycontroller.Then,
theusercanuseeithertheprimarycontrollerorsecondarycontroller
toconfigureandsetuptheZXT120usingZWavesconfiguration
commandclass.Oncetheconfigurationandsetupiscomplete,the
controllercanuseZWaveThermostatcommandsclasstocontrol
theirIRcontrolledairconditionerthroughtheZXT120.

ControllerandGatewayRequirements

TheZXT120canworkwithanyZWavecompliantcontrolleror
gatewaysupportingthefollowingZWavecommands.
- ConfigurationCommandClass
- MultilevelSensorCommandClass
- ThermostatCommandClass
ThermostatModeCommandClass
ThermostatFanModeCommandClass
ThermostatSetpointCommandClass

BuiltinIRcodelibrary

TheBuiltinIRcodelibrarysupportsmostofthepopularair
conditionerbrandsinthemarket.ZWavegatewayandcontroller
doesnotneedtohaveanyIRcontrolcodeknowledge.UsercanuseZ
WavecontrollerorgatewaytoselecttheIRcodeaccordingtotheZXT
120codelistseparatelyprovidedthroughZWaveconfiguration
command.

4
Glossary
Deviceor Devicesandnodesarealltermstodescribean
individualZWavedevice.Theseareall
Node interchangeablewhensettingupyourZWave
network.

Inclusion AddaZWavedevicetothenetwork.
Exclusion DeleteaZWavedevicefromthenetwork.
Totakeadeviceoutofagroup,sceneor
Remove associationgroupwhilethatdevicestillexists
inthesameZWavenetwork.
AcollectionofZWavedevicesiscontrolledby
primaryandsecondarycontrollersoperating
ZWave
onthesamesystem.AZWavenetworkhasits
Network
ownuniqueIDcodesothatcontrollersnotin
thenetworkcannotcontrolthesystem.
Thefirstcontrollerisusedtosetupyour
devicesandnetwork.OnlythePrimary
Primary Controllercanbeusedtoincludeordelete
Controller devicesfromanetwork.Itisrecommended
thatyoumarktheprimarycontrollerforeach
networkforeaseinmodifyingyournetwork.
Acontrollercontainingnetworkinformation
aboutotherdeviceswithinthenetworkandis
Secondary usedforcontrollingdevices.Secondary
Controller controlleriscreatedfromthePrimary
Controllerandcannotincludeordeletedevices
tothenetwork.
Acontrollercontainingnetworkinformation
aboutotherdeviceswithinthenetworkandis
usedforcontrollingdevices.Inclusion
Inclusion
controlleriscreatedfromthePrimary
Controller
ControllerinaSISenabledZWavenetwork.
InclusionControllershavetheabilitytoadd
andremovedevicesfromthenetwork.

5
ZXT120Operations

BeforeusingtheZXT120,pleasereadthe[INSTALLATION]ifyouneed
tomounttheZXT120toawall.PoweruptheZXT120bytheUSB
Power5VdcorDrybatteryAAAx3pcs.

Plugin5VdcpowerintotheUSBsocketifoperatedatAlways
Listeningmode.Or
Install3xAAAbatteriesifoperatedatFLiRSmode.
Pleaserefertothesectionof[MOUNTINGPROCEDURE].
RemovethebatterycoveronthebackofyourZXT120battery
chassis.
Mountthebatterycoverintothemainunitwith2screws.
Checkthepolarityofthebatteriesandthe"+/"marksinsidethe
batterycompartment.
Insertthebatteries.
Pushthebatterycoverandmainunitbackinplace.

LCAUTION(batteryandpoweradaptorsafety)
Usenewbatteriesoftherecommendedtypeandsizeonly.
Nevermixusedandnewbatteriestogether.
Toavoidchemicalleaks,removebatteriesfromtheZXT120if
youdonotintendtousetheremoteforanextendedperiod
oftime.
Disposeofusedbatteriesproperly;donotburnorburythem.

(Pleasecarefullyreadthroughthefollowingthenstorethemanualfor
futurereference.)

6
ProductOverview

Temperature sensor

PROG Button,
Learning and LED
Indication

Battery
chassis

External USB Power


IR Port 5V DC

Surround IR Output for


top and 4-directions

Figure 2 PROG Key and IR Port of ZXT-120

7
ZWaveRemoteControl

1) Selectyouroperationmode;pleaserefertoListeningMode
section.
2) IncludeorExcludetheunitfromtheexistingZWavehome
controlnetworkwithyourprimarycontroller.
Refertoyourprimarycontrollerinstructionstoprocess
theinclusion/exclusionsetupprocedure.
Whenpromptedbyyourprimarycontroller,clickonce
onthePROGbutton.
Theprimarycontrollershouldindicatethattheaction
wassuccessful.Ifthecontrollerindicatestheactionwas
unsuccessful,pleaserepeattheprocedure.
3) Usercanuseeitherprimarycontrollerorsecondarycontroller
(shouldsupportconfigurationcommandclass)tosetuptheZXT
120ACcodebytheparameter27(IRcodenumberforbuiltin
codelibrary),pleaserefertocodelistfortheparametervalue
thensetupyourACcontrolcode.
4) Oncetheconfigurationandsetupwerecompleted,the
controllercanuseZWaveThermostatcommandsclassto
controltheirIRcontrolledairconditionerwiththeZXT120.
5) Youcanrecorddownyourdevicecodeunderthebelowtablefor
futurereferenceaftersettinguptheZXT120correctly.

ACdeviceprogrammedtoyourZXT120
Codeno.:

8
ZXT120Information

HowtogettheNIFNodeInformationFrameonZXT120(Inclusion)

LEDIndicationStatus
Step SetupKey
onZXT120
PressthePROGbuttononthe LEDflashesonce
ZXT120 thenstayoff
1 (ZXT120willreport
thesupported
commandclass)

ParameterNo.andParameterValueofconfigurationcommand

Parameter
Definitions ParameterValue
Number
25 IndicatealocationforIRcode 022
(0x19) learningandstartlearning (0x000x16)
26 Learningstatusregister 0x00:IdlethisIR
(0x1A) channelisidle
(default)

Note: 0x01:OKthelatest
Thestatusvalue0x01and learningprocess
0x04willberesetto0when successfuland
theZXT120receiveaget completed
commandtothisparameter
0x02:Learningthe
ZXT120isbusy
processingprevious
learningrequest

0x04:Failedthe
latestlearning
requestfailed
27 IRcodenumberforbuiltin ReferCodelistfor
(0x1B) codelibrary details
28 ExternalIREmitterpower 0x00:normalpower
(0x1C) level mode
0xFF:highpower
mode(default)
32 SurroundIRcontrol 0x00:disable
(0x20) - toavoidtheIRinterference SurroundIREmitters
bydisablingthe 0xFF:enable
surroundingIRemitterif2 SurroundIREmitters

9
airconditionersinaroom (default)
areused
- extendthebatterylifeby
disablingtheSurroundIR
Emitters
33 ACfunctionSWINGcontrol 0x00:SWINGOFF
(0x21) 0x01:SWINGAUTO
(Default)
35 Learnlocationstatus Bitmask=1,learn
(0x23) locationhaslearn
data.Otherwise,Bit
mask=0
SeefigureLearn
locationasbelow
Onbelowexample,location1,7,8,12,16arelearned
data.
7 6 5 4 3 2 1 0
1 0 0 0 0 0 1 0 BitMaskByte1
Location07

7 6 5 4 3 2 1 0
0 0 0 1 0 0 0 1 BitMaskByte2
Location815

7 6 5 4 3 2 1 0
BitMaskByte3
0 0 0 0 0 0 0 1
Location1623

7 6 5 4 3 2 1 0
BitMaskByte4
0 0 0 0 0 0 0 0
[Reseved]

Figure:Learnlocation
37 Sensortemperature Temperatureoffset
(0x25) compensation value.

(Thisparameterisusedto Formula:
compensatethetemperature Displaytemperature
errorattemperaturesensor) =sensorreading
value+offsetvalue
(unit=degreeC)
o
0x00=0 C(Default)
o
0x01=1 C
o
0x02=2 C
o
0x03=3 C
o
0x04=4 C
o
0x05=5 C

10
o
0xFF=1 C
o
0xFE=2 C
o
0xFD=3 C
o
0xFC=4 C
o
0xFB=5 C
ParameterTable

LMappingInformation

BASICSetValue0x00willmaptoThermostatmodeOff0x00.
BASICsetValue0xFFwillmaptoThermostatmodeResume0x05.

ListeningModeChange(defaultmodeisFLiRS)

ZXT120canbeconfiguredaseitherFrequentlyListeningRouting
Slaves(FLiRS)orAlwaysListeningnodeafterexclusionprocess.

FLiRSnodetypeistargetedforbatteryoperatedapplicationsandit
willentersleepmodefrequentlyinordertoconservebattery
consumption.

AlwaysListeningnodetypeistargetedfortheneedsofrequiredafast
responseapplication.

Important:
ItisnotallowedtochangingZXT120operationmodewithout
exclusionprocess(donotchangeZXT120operationmodewhileZXT
120isincludedinanetwork).

HowtoswitchZXT120listeningmodefromAlwaysListeningto
FLiRS(orviceverse)

LEDIndicationStatus
Step SetupKey
onZXT120
PressandholdthePROGbuttonon LEDstayoff
1 theZXT120foraround5seconds
Releasethebuttonandthenpress LEDflashestwice
thePROGbutton3timeswithin2 thenstayoff
2 seconds (ZXT120setinFLiRS
mode)

11
OR
LEDflashesfour
timesthenstayoff
(ZXT120setin
AlwaysListening
mode)

IRCodeSelection

ZXT120iswithbuiltinIRACcodelibrary,usermayselecttheIRcode
usingConfigurationCommandClass.

LEDIndicationStatus
Step SetupKey
onZXT120
AfterincludedZXT120toZWave
controllerorGateway,gotodevice
1
setupforconfigurationongateway
orcontroller.
Inputparameternumber27and
parametervalue(pleaselookupthe
2 codelistofZXT120accordingto
yourACbrand).Thencompletethe
configurationprocess.
PressthePROGbuttonontheZXT LEDflashesonce
120.(thisstepapplywhenusing whenZXT120
3 ZRC100orotherportablecontroller receivesthe
forsetup,ifusinggateway,usercan configuration
skipthisstep) setting
GobacktothecontrolpageofZXT LEDflashesonce
120onthegatewayandtrythe everytimeit
functionsuchas(cool,temperature receivesa
set). commandfrom
gateway
4 Iftheairconditionerdoesnot
respondtothecommandyouseton
Gateway(Cool,Heat,Auto,
Temperaturesetetc.),repeatstep2
and3toselectthenextcodeon
codelist.

12
LImportantInformation
Different brand or model of air conditioner has different
function. For example, some air conditioner only support
o o o
temperaturesetfrom18 C30 C,ifuserset17 Congateway,
ZXT120willnotrespond.
There are more than 1 code for each brand, some does not
support heat, if user selected a code that does not support
heat but the original air conditioner supports heat function,
please continue to try next code until the correct one is
selected.
Ifnoneofthecodeworksonthetargetairconditioner,orthe
air conditioner brand is not shown on the code list, please
selectcode000forIRcodelearning(refertoinstructionof
IRCodeLearning)

IRCodeLearning

Incasenoneofthecodeonthecodelistworksforthetargetedair
conditioner,usercanuseIRcodelearningfunctionusingconfiguration
accordingtobelowsteps:

LEDIndicationStatus
Step SetupKey
onZXT120
Gotoconfigurationsettingpageon LEDflashesonce
thegatewayorZRC100andinput whenZXT120
parameternumber27and receivesthe
1
parametervalue000toselectthe configuration
dedicatedACcodenumber000 setting
forlearning.
Lookupbelowmappingtable(value
022)forlearning,anddecidetheIR
settingyouintenttolearnnext.
Forexample22C,coolwhich
matchesvalue5(IRcodetobe
2 learntwilllocateat5inZXT120).
Setyouroriginalairconditioner
remoteat22C,coolandturnit
off.(Besidestemperatureand
mode,youmaysetotherdesired
settings,suchasFan,Swingetc.)
Gotoconfigurationsettingpageon
3 thegatewayorZRC100andinput
parameternumber25and
13
parametervalue5(inthiscase).
PressthePROGbuttonontheZXT LEDflashesonce
120.(thisstepapplywhenusing whenZXT120
ZRC100orotherportablecontroller receivesthe
4 forsetup,ifusinggateway,usercan configuration
skipthisstep) setting
ZXT120isreadyto
learn
Aimtheoriginalairconditioner LEDflashestwiceif
remoteatZXT120accordingto learningissuccessful.
belowpositionwithin13inches
LEDflashes6timesif
itsfailed.

5

Presspoweronbuttononthe
originalairconditionerremote.

Ifthelearningisfailed,repeatstep3
tostep5.
TolearnnextIRcode,repeatstep2
tostep5.

LWhenyouencounterproblem,checkfollowings:
Makesureyouroriginalremoteisswitchedtopoweroff.
Press the key on original remote before learning mode
timeout.
Keepawayfromincandescentlightanddirectsunlightduring
learning.
MakesureIRTransmitterofyouroriginalremotealightwith
learningdiodeofZXT120,youmayalsoslightadjustcloseror
further away the distance of two devices. Some of remotes
theIRtransmitterinhiddenbehindlensandmaynotinstalled
centerofremote.
Makesurethepowerisgoodonbothdevices,especiallythe
originalremote.Usefreshbatteries.

14
IRLearningMappingTable(Parameternumber25)

ParameterValue Thermostatcommand

(Location) &IRsetting
0 OFF
1 ON(resume)
2 19Ccool
3 20Ccool
4 21Ccool
5 22Ccool
6 23Ccool
7 24Ccool
8 25Ccool
9 26Ccool DefaultCool
10 27Ccool
11 28Ccool
12 19Cheat
13 20Cheat
14 21Cheat
15 22Cheat DefaultHeat
16 23Cheat
17 24Cheat
18 25Cheat
19 26Cheat
20 27Cheat
21 28Cheat
22 Drymode

15
LImportantInformation
Afteralllearningcompleted,usercangobacktotheZXT120
controlpageonthegatewayfornormaloperation.
OnthegatewayUI,usercanonlyusethetemperaturerange
from the mapping table, OFF, ON(RESUME), COOL, HEAT,
DRY,IfuserpressthebuttonofFAN,orotherfunctiononthe
gatewayUIwhichisnotlistedinabovetable,ZXT120willnot
respond.
IfuseronlylearntON,OFF,orpartofthesettingsaccording
to the above table, ZXT120 will send the learnt data to the
air conditioner only. For example, user only learnt ON, OFF,
22C Cool, 24C Heat, ZXT120 will not send IR data to air
conditionerifuserset27CCoolonthegateway.
ZXT120 has been predefined default cool at 26C, default
heat at 22C, when user press Cool on gateway without
settingtemperature,ZXT120willsendthelearntdataof26C
Cool to air conditioner. When user press Heat on gateway
without setting temperature, ZXT120 will send the learnt
dataof22CHeattoairconditioner.
There is only one code for dry mode, user can set it at any
preferredtemperature.
Usercanstillusegatewaytosetupsceneandschedulewith
ZXT120,forexample,tohaveACturnonat23Ceverydayat
7pm,25Cat11pm.Justmakesurethesetcodeislearnt.
The learning mapping table is for split air conditioner which
remote control is with LCD display. For window type air
conditioner (which remote control is without LCD display),
the mapping table with temperatures do not apply, due to
differenttypeofIRcontrolprotocol.However,usermaystill
usetheOFF,orON/RESUME,DRYkeyforlearning.(Because
thePOWERkeyontheoriginalremotewithoutLCDdisplayis
toggle, user can choose either ON key, or OFF key to learn
Power key, after learning is done, press once to turn on the
airconditioneriftheairconditionerisOFF,pressoncetoturn
offiftheairconditionerisON)

16
ResetZXT120tofactorydefault

PressandholdPROGbuttonfor10secondsonZXT120.TheLEDwill
flashtwiceuntilresetprocessiscompleted.

Note:ThisresetstepwillnotaffecttheoperationmodeofZXT120,
usershouldrefertoListeningModesectionifyouwanttochange
theoperationmode.

LInformation
If you are using Gateway or other Zwave controllers to
operate ZXT120, Please follow the instruction from the
gatewayorothercontroller.
Youcancheckeitherthespecificationsinthemanualofyour
ZXT120 or also check online at www.remotec.com.hk for a
fulllistofproductsthatcanbeusedwithyourZXT120.

17
INSTALLATION
MOUNTINGTHEZXT120TOAWALL

MOUNTINGLOCATIONPRECAUTIONS
Beforemounting,checkthematerialandstructureofthe
mountinglocation.Ifthelocationdoesnothavetheproper
materialorstructure,theZXT120canfallandcauseinjuries.
Usecommercialitemsthatbestmatchthewallstructureand
materialforthescrewsandotherfixtures.
Donotmountnearakitchencounter,humidifier,orother
locationinwhichitcanbeexposedtosmokeorsteam.Doingso
couldcauseafireorelectricalshock.
Donotmountinlocationswithhighhumidityorlargeamountsof
dust.Doingsocouldcauseafireorelectricalshock.
Donotmounttolocationssubjecttohightemperatures,high
humidity,orexposuretowater.Doingsocouldcauseafireor
electricalshock.
Donotmounttolocationssubjecttolargeamountsofvibration,
largejolts,orlargeforces.ThesecouldcauseaninjuryiftheZXT
120fallsandbreaks.

MOUNTINGPROCEDUREPRECAUTIONS
DonotmodifypartsorusetheZXT120inwaysotherthanits
intendeduse.DoingsocouldcausetheZXT120tofallandresult
inaninjury.
Besuretofullycheckthattherearenoelectricalwiresorpipes
insidethewallbeforemounting.
Ifanyofthescrewsareloose,theZXT120canfallandcausean
injury.DonotmounttheZXT120withthescrewsstillloose.
Checkthatthetwoscrewsmountedtothewallarefullyinserted
intothekeyholesoftheZXT120.Otherwise,theZXT120canfall
andcauseaninjury.
DonotmounttheZXT120sothatitsticksoutfromthewalledge.
Itcouldgethitbypeoplesbodiesorobjectsandcauseaninjury.
Supplierwillnotbeliableforanyaccidentsorinjuriesthatoccur
duetoimpropermountingorhandling.
Whenmounting,becarefulnottogetyourfingerspinchedor
injureyourhands.

MOUNTINGPROCEDURE
TheZXT120canbemountedtoawallorwoodenracksusingthetwo
keyholesinthebottomcase.

Note 1: The reception sensitivity varies depending on the antenna


direction.

18
Note 2: Before mounting to a wall, be sure to fully read the precautions.

1. Obtaintwoscrewssuitableforthewallstrengthandmaterial.
Thescrewsizeisshowninthefigurebelow.



2. ThepositionalrelationshipbetweentheZXT120keyholesand
thescrewmountingpositionsareshowninthefigurebelow.
Note 1: When mounting the screws to the wall, leave a space
between the wall and screw cap as shown in the figure.

3. InserttheZXT120keyholesontothetwoscrewsmountedto
thewall,andthenslidedownwardtosecureinplace.

4. AftersecuringtheZXT120tothewall,connecttheUSBPower
orbatteriesandIRemittercabletotheZXT120.

19
Note 1: Check that the ZXT-120 is firmly secured to the wall.
Note 2: Insert USB plug or batteries and IR emitter cable so that
they are firmly connected to the ZXT-120.

5. WhenremovingtheZXT120fromthewall,liftuptheZXT120,
thenpullittowardsyou.

6. Detachthemainunitfromthebatterychassisbymovetoward
totopposition.

20
WIRELESSINFORMATION
Wirelessrange:
Thisdevicehasanopenairlineofsighttransmissiondistanceof100
feetwhichcomplieswiththeZWavestandards.Performancecanvary
dependingontheamountofobjectsinbetweenZWavedevicessuch
aswallsandfurniture.EveryZWavedevicesetupinyournetworkwill
actasasignalrepeaterallowingdevicestotalktoeachotherandfind
alternateroutesinthecaseofareceptiondeadspot.
Radiofrequencylimitations:
1. Eachwallorobject(i.e.:refrigerator,bookshelf,largeTV,etc)can
reducethemaximumrangeof65feetbyupto25to30%.
2. Plasterboardandwoodenwallsblocklessoftheradiosignalthen
concrete,brickortilewallswhichwillhavemoreofaneffecton
signalstrength.
3. WallmountedZWavedeviceswillalsosufferalossofrangeif
theyarehousedinmetaljunctionboxeswhichcouldalsoreduce
therangebyupto25to30%.

MAINTENANCE

1 DonotexposeyourZXT120todust,strongsunlight,humidity,
hightemperaturesormechanicalshocks.
2 Donotuseoldandnewbatteriestogetherasoldbatteriestendto
leak.
3 DonotusecorrosiveorabrasivecleansersonyourZXT120.
4 Keeptheunitdustfreebywipingitwithasoft,drycloth.
5 DonotdisassembleyourZXT120,itcontainsnouserserviceable
parts.

FREQUENTLYASKEDQUESTIONS

ZWaveFrequentlyAskedQuestions

Q WhywontmyZXT120workwiththeZWavedevicesI
purchasedfromanothercountry?
A DuetodifferentcountriesregulationsZWaveproductsfrom
differentregionsaresettodifferentfrequencies.Before
purchasingnewdevicesmakesureyouhavecheckedthatthe
deviceiscompatibleinyourregion.

Q HowdoIknowwhichproductiscompatiblewithmyZXT120?
A ZXT120shouldworkwithanyZWavecontrollerorgatewaythat
hascontrolcapabilityforThermostatdevices.Youcancheck
eitherthespecificationsinthemanualofyourZXT120oralso
checkonlineatwww.remotec.com.hkforafulllistofproducts
thatcanbeusedwithyourZXT120.AllZWaveproductsalso
comewiththeZWavelogo.

21


Q CanIusetheUSBporttoconfigureZXT120?
ANo,theminiUSBportonlyprovidesanalternativeoptionforuser
topowertheZXT120.

Q DoIneedanelectriciantoinstallZWaveproductsinmyhouse?
A Installationcanbesimple.Insomecasesallyouneedtodois
mounttheZXT120toawallorwoodenracks.Youalsocanplace
theZXT120onthedeskandpoweritwithdrycellbatteries.

Q HowtoselectmyairconditionerIRcodefromZXT120?
A Youshouldrefertothecodelistandlookintothebrandandtry
thecodeno.sequentiallyuntilyoufindtherightcode.Youcan
recorddownyourdevicecodeunderthetableforfuture
referenceaftersettinguptheZXT120correctly.

Q ZXT120isworkingontopand4directionsIRoutput,butthere
isnoresponseontheIRemittersocket,why?
A ZXT120supportstwoIRpowerlevelsfortheexternalIRemitter
toavoidsaturationoftheIRreceiver.YoucansettheIRoutput
powerlevelbytheParameterTablevalue(normalorhighpower
mode)oradjustthepositionofyourexternalIRemitter.

Q CanIuse2ormoreZXT120inmyhouse?Whatisthemax.units
ifyes?
A Yesanditisverydependonthecapabilityofgateway/controller.
Forexample,gatewaycansupportsupto8,16or32ZXT120ina
network.

Q HowtoavoidtheIRinterferenceifIamusing2identicalair
conditionersinsamelocationbutwanttocontrolthem
individually?
A UsercandisabletheSurroundIROutputfunction,connectthe
externalIRemitterandaimitatthespecificACunit.The
operatingdistanceofexternalIRemitterisaround100cm(High
powermode)and50cm(Lowpowermode)butitisalsodepends
onthesensitivityoftheIRreceiver.


ExternalIRemittercable

22
Q WherecanIkeepuptodatewiththelatestZWaveproductsfor
myhouse?
A Youcankeepuptodatebyvisitingthewww.remotec.com.hk
websitewherewewillhaveinformationandideasforusingZ
Wavetechnology.

TECHNICALSPECIFICATIONS

BW8377EU(ZXT120EU)
BW8377AU(ZXT120AU)
Modelno.
BW8377US(ZXT120US)
BW8377IN(ZXT120IN)
868.4MHz(EU)(ZXT120EU)
921.4MHz(AU)(ZXT120AU)
RFfrequency
908.4MHz(US)(ZXT120US)
865.22MHz(IN)(ZXT120IN)
upto80ftoutdoorlineofsight,inunobstructed
RFoperatingdistance
environment
IRoperatingdistance upto25ftlineofsight,inunobstructedenvironment

IRlearning Max.23commands
Measurablerange:32104F/040C
Reportresolution:1degreeC
Temperature
Operation:040C
Storage:2060C
USBPowerDC5V100mAor
Poweredby
DrybatteryAAAx3pcs
Dia.=70mm,T=18mm(Mainunit)
Dimension
Dia.=70mm,T=15.5mm(Batterychassis)
35g(Batterychassisexcluded)
Weight 60g(Batterychassisincluded)
90g(Main+Batterychassis+AAAx3pcs)

ZWavedevicetype

BasicDeviceClass:BASIC_TYPE_ROUTING_SLAVE

GenericDeviceClass:GENERIC_TYPE_THERMOSTAT

SpecificDeviceClass:SPECIFIC_TYPE_THERMOSTAT_GENERAL_V2

ZWaveCommandClass Version Controlled Supported

COMMAND_CLASS_THERMOSTAT_MODE Version2 NO YES

COMMAND_CLASS_THERMOSTAT_SETPOINT Version2 NO YES

COMMAND_CLASS_THERMOSTAT_FAN_MODE Version2 NO YES

23
COMMAND_CLASS_BATTERY Version1 NO YES

COMMAND_CLASS_CONFIGURATION Version1 NO YES

COMMAND_CLASS_BASIC Version1 NO YES

COMMAND_CLASS_VERSION Version1 NO YES

COMMAND_CLASS_SENSOR_MULTILEVEL Version1 NO YES

COMMAND_CLASS_SWITCH_ALL Version1 NO YES

COMMAND_CLASS_MANUFACTURER_SPECIFIC Version1 NO YES

SupportedfunctioninThermostatCommandClass
ZWavecommandclass Description Supported
Auto/AutoLow YES

Low YES

AutoHigh YES
ThermostatFanmode
High YES

AutoMedium YES

Medium YES

Heating YES

Cooling YES

Furnace NO

DryAir YES

ThermostatSetpoint MoistAir NO

Autochangeover YES

EnergySaveheating NO

EnergySavecooling NO

Awayheating NO

ThermostatMode Off YES

Heat YES

Cool YES

Auto YES

Auxiliary/EmergencyHeat NO

Resume YES

Fanonly YES

Furnace NO

24
DryAir YES

MoistAir NO

AutoChangeover YES

EnergySaveHeat NO

EnergySaveCool NO

AWAY NO

ZXT120functionsandParameterssummaries:
AIR
Z-WAVE COMMAND
FUNCTIONS CONDITIONER Z-WAVE COMMAND CLASS
COMMAND PARAMETER
FUNCTION

COMMAND_CLASS_THERMOSTAT THERMOSTAT_
MODE = 5
_MODE MODE_SET
POWER ON

COMMAND_CLASS_BASIC BASIC_SET VALUE = 0XFF

POWER
COMMAND_CLASS_THERMOSTAT THERMOSTAT_
MODE = 0
_MODE MODE_SET
POWER OFF

COMMAND_CLASS_BASIC BASIC_SET VALUE = 0X00

COMMAND_CLASS_THERMOSTAT THERMOSTAT_
AUTO MODE = 3
_MODE MODE_SET

COMMAND_CLASS_THERMOSTAT THERMOSTAT_
COOL MODE = 2
_MODE MODE_SET

COMMAND_CLASS_THERMOSTAT THERMOSTAT_
FAN MODE = 6
_MODE MODE_SET
MODE
COMMAND_CLASS_THERMOSTAT THERMOSTAT_
HEAT MODE = 1
_MODE MODE_SET

COMMAND_CLASS_THERMOSTAT THERMOSTAT_
DRY MODE = 8
_MODE MODE_SET

AUTO COMMAND_CLASS_THERMOSTAT THERMOSTAT_


MODE = 10
Changeover _MODE MODE_SET

SETPOINT TYPE =

HEAT mode 1,

Temperature TEMPERATURE
VALUE

SETPOINT TYPE =
COOL mode 2,
Temperature TEMPERATURE
TEMPERATURE COMMAND_CLASS_THERMOSTAT THERMOSTAT_ VALUE
SETTING _SETPOINT SETPOINT_SET SETPOINT TYPE =

DRY mode 8,

Temperature TEMPERATURE
VALUE

SETPOINT TYPE =
AUTO mode 10,
Temperature TEMPERATURE
VALUE

THERMOSTAT_
COMMAND_CLASS_THERMOSTAT
FAN SPEED FAN AUTO FAN_MODE_SE FAN MODE = 0
_FAN_MODE, v1
T

25
THERMOSTAT_
COMMAND_CLASS_THERMOSTAT FAN MODE = 0, 2, or
FAN_MODE_SE
_FAN_MODE, v2 4
T

THERMOSTAT_
COMMAND_CLASS_THERMOSTAT
FAN_MODE_SE FAN MODE = 1
_FAN_MODE, v1
T
FAN LOW (1/3)
THERMOSTAT_
COMMAND_CLASS_THERMOSTAT
FAN_MODE_SE FAN MODE = 1
_FAN_MODE, v2
T

- - -

FAN MID (2/3) THERMOSTAT_


COMMAND_CLASS_THERMOSTAT
FAN_MODE_SE FAN MODE = 5
_FAN_MODE, v2
T

THERMOSTAT_
COMMAND_CLASS_THERMOSTAT
FAN_MODE_SE FAN MODE = 3
_FAN_MODE, v1
T
FAN HIGH (3/3)
THERMOSTAT_
COMMAND_CLASS_THERMOSTAT
FAN_MODE_SE FAN MODE = 3
_FAN_MODE, v2
T

PARAMETER NO. =
33

SWING ON/ COMMAND_CLASS_CONFIGURATI CONFIGURATIO


SIZE = 1
SWING AUTO ON N_SET

VALUE = 1

SWING
PARAMETER NO. =
33

COMMAND_CLASS_CONFIGURATI CONFIGURATIO
SWING OFF SIZE = 1,
ON N_SET

VALUE = 0

PARAMETER NO. =
27

COMMAND_CLASS_CONFIGURATI CONFIGURATIO
IR CODE SETUP SIZE = 2,
ON N_SET

VALUE = (CODE#)

PARAMETER NO. =
28

NORMAL COMMAND_CLASS_CONFIGURATI CONFIGURATIO


SIZE = 1,
POWER LEVEL ON N_SET

IR VALUE = 0

TRANSMISSION
PARAMETER NO. =
POWER LEVEL
28

HIGH POWER COMMAND_CLASS_CONFIGURATI CONFIGURATIO


SIZE = 1,
LEVEL ON N_SET

VALUE = 0xFF

FRONT IR COMMAND_CLASS_CONFIGURATI CONFIGURATIO PARAMETER NO. =


DISABLE
TRANSMISSION ON N_SET 32
CONTROL
SIZE = 1,

26
VALUE = 0

PARAMETER NO. =
32

COMMAND_CLASS_CONFIGURATI CONFIGURATIO
ENABLE SIZE = 1,
ON N_SET

VALUE = 0xFF

BATTERY
COMMAND_CLASS_BATTERY BATTERY_GET
LEVEL

VERSION COMMAND_CLASS_VERSION VERSION_GET

MANUFACTURE
MANUF'ER COMMAND_CLASS_MANUFACTUR
R_SPECIFIC_GE
SPECIFIC ER_SPECIFIC
T

TEMPERATURE COMMAND_CLASS_SENSOR_MUL SENSOR_MULTI

SENSOR TILEVEL LEVEL_GET

27
CHECKINGACCESSORIES
Afteropeningthecoverofthepackingbox,checkthatthefollowing
accessoriesareincluded.
ZXT120(ZWavetoACIRExtender)
Screws(bottomcover)x2pcs
ZXT120UserManual(downloadfromourwebsite)
ACCodeList(downloadfromourwebsite)

FCCNOTICE
ThisdevicecomplieswithPart15oftheFCCrules.Operationis
subjecttothefollowingtwoconditions:
(1)thisdevicemaynotcauseharmfulinterference,and
(2)thisdevicemustacceptanyinterferencereceived,including
interferencethatmaycauseundesiredoperation.

WARNINGS
Changesormodificationsnotexpresslyapprovedbytheparty
responsibleforcompliancecouldvoidtheuser'sauthoritytooperate
theequipment.
RISKOFFIRE
RISKOFELECTRICALSHOCK
RISKOFBURNS
Thesocketoutletshallbeinstalledneartheequipmentand
shallbeeasilyaccessible.
Useonlypowersupplieslistedintheuserinstructions.

Donotdisposeofelectricalappliancesasunsortedmunicipalwaste,
useseparatecollectionfacilities.Contactyourlocalgovernmentfor
informationregardingthecollectionsystemsavailable.

CAUTION
RISKOFEXPLOSIONIFBATTERYISREPLACEDBYANINCORRECT
TYPE.
DISPOSEOFUSEDBATTERIESACCORDINGTOTHEINSTRUCTIONS.

28
WARRANTY

ONEYEARLIMITEDWARRANTY:Remotecwarrantsthisproducttobe
freefromdefectsinmaterialsandworkmanshipundernormaluse
andserviceforaperiodofoneyearfromtheoriginaldateofpurchase
fromthedistributorordealer.

REMOTECshallnotbeliablefor:
z damagescausedbydefectivedevicesforindirect,incidental,
special,consequentialorpunitivedamages,including,interalia,
lossofprofits,savings,data,lossofbenefits,claimsbythird
partiesandanypropertydamageorpersonalinjuriesarising
fromorrelatedtotheuseofthedevice.
z Servicetripstoprovideinstructiononproductuse.
z Shippingcostsforreplacementproducts.

Thiswarrantyislimitedtotherepairorreplacementofthisproduct
only,ifthepurchasedatecannotbesubstantiated,thewarranty
periodwillbeginonthedateofmanufactureasindicatedonthis
product.AllwarrantyclaimsmustbemadetoRemotecappointed
distributorsordealersduringtheapplicablewarrantyperiod.This
warrantygivesyouspecificlegalrightandyoumayalsohaveother
rightswhichvaryineachcountry.

www.remotec.com.hk
PrintedinChina F82083770000