You are on page 1of 7

Multi-rate OC-48/STM-16 LR-2/L-16.

2 SFP
DWDM Transceivers with Digital Diagnostics
TRPW48L2/E2 DWDM

Product Description

The TRPW48L2/E2 DWDM SFP series of multi-rate fiber optic transceivers


with digital diagnostics monitoring functionality provide a quick and reli-
able interface for long reach applications. Diagnostics monitoring func-
tionality (alarm and warning features) is integrated into the design via an
I2C serial interface per the Multi-Source Agreement (MSA) on DWDM SFP
transceivers (Rev. 1.0, October 2005).
Products under this series are compatible with SONET/SDH standards for
OC-48/STM-16 (2.67Gb/s) Forward Error Correction and OC-48/STM-16
(2.488Gb/s) LR-2/L-16.2 long reach applications, OC-3/STM-1 (156Mb/s)
and OC-12/STM-4 (622Mb/s) SR/I-1 and I-4 short reach applications; Gigabit
Ethernet LX (1.25Gb/s) applications per IEEE 802.3; and Fibre Channel
200-SM-LC-L (2.125Gb/s) and 100-SMLC-L (1.062Gb/s) applications per
FC-PI standards. The transmitter incorporates a highly reliable DFB laser Features
with an operating wavelength in full compliance with 100GHz (0.8nm)
spacing per ITU-grid. All transceivers are Class I Laser products per U.S. Compliant with DWDM SFP MSA
FDA/CDRH and international IEC-60825 standards. Multi-rate Operations from 155Mb/s to 2.67Gb/s
The TRPW48L2/E2 DWDM transceivers connect to standard 20-pad SFP Support 2.67Gb/s OC-48 FEC Rate
connectors for hot plug capability. This allows the system designer to DFB Laser Transmitter & APD Receiver
make configuration changes or maintenance by simply plugging in
different types of transceivers without removing the power supply from Long Haul Transmission Distance of 80km or 120km
the host system. Compliant with G.692
The transceivers have blue bail-type latches, which offer an easy and 100GHz Channel Spacing
convenient way to release the modules. The latch is compliant with the
Optical Link Power Budget of 28dB Minimum
SFP MSA.
Digital Diagnostics through Serial Interface
The transmitter and receiver DATA interfaces are AC-coupled internally.
LV-TTL Transmitter Disable control input and Loss of Signal (LOS) output Internal Calibration for Digital Diagnostics
interfaces are also provided. The transceivers operate from a single +3.3V Eye Safe (Class I Laser Safety)
power supply over an operating case temperature range of -5C to +70C
Hot-pluggable
(Commercial) or -5C to +85C (Extended). The housing is made of metal
designed for optimum thermal performance and electromagnetic com- TX Fault & Loss of Signal Outputs
patibility. TX Disable Input
Wide Case Operating Temperature Range

Absolute Maximum Ratings


Parameter Symbol Minimum Maximum Units
Storage Temperature TST - 40 + 85 C
Commercial -5 + 70
Operating Case Temperature1 TOP C
Extended -5 + 85
Supply Voltage VCC 0 + 4.5 V
Maximum Input Optical Power (30 seconds max.) Pin, max - + 3.0 dBm
Input Voltage VIN 0 VCC V
1
Measured on top side of SFP module at the front center vent hole of the cage.

An Oplink Company 21737-0456. v08. 2010.05.11


TRPW48L2/E2 DWDM
Transmitter Performance Characteristics (Over Operating Case Temperature. VCC = 3.13 to 3.47V)
All parameters guaranteed only at typical data rate

Parameter1 Symbol Minimum Typical Maximum Units


Operating Data Rate B 0.155 - 2.67 Gb/s
Average Optical Output Power
PO 0 - + 4.0 dBm
(coupled into single mode fiber), 50% duty cycle
Extinction Ratio Phi /Plo 8.2 - - dB
Center Wavelength 2
C see Ordering Information Table -
Spectral Width (-20dB) 3
20 - - 0.4 nm
Optical Output Power of OFF Transmitter POFF - - - 45.0 dBm
Side Mode Suppression Ratio SMSR 30 - - dB
Optical Rise/Fall Time (20% to 80%) t r , tf - - 0.16 ns
Relative Intensity Noise RIN - - - 117 dB/Hz
Jitter Generation OC-48 JG - - 0.07 UIp-p
1600ps/nm (80km) - - 2.0
Dispersion Penalty4 - dB
2400ps/nm (120km) - - 2.0
Optical Output Eye Compliant with Telcordia GR-253-CORE and ITU-T Recommendation G.957
1
Specified through EOL.
2
BOL: +/-0.05nm from ITU grid.
EOL: +/-0.1nm from ITU grid.
3
Measured with OSA and 0.1nm resolution bandwidth.
4
Corresponds to the approximate worst-case dispersion for G.652/G.654 fiber over the center wavelength range of 1528.77-1563.86nm.

Receiver Performance Characteristics (Over Operating Case Temperature. VCC = 3.13 to 3.47V)
All parameters guaranteed only at typical data rate

Parameter1 Symbol Minimum Typical Maximum Units


Operating Data Rate B 0.155 - 2.67 Gb/s
Receiver Sensitivity
OC-3/12/48, 2.67Gb/s Pmin - 28.0 - - dBm
(10 -10 BER) 2
Receiver Sensitivity 2.125Gb/s, 1.25Gb/s,
Pmin - 28.0 - - dBm
(10 -12 BER) 3 1.062Gb/s, 0.125Gb/s
Maximum Input Optical Power (10-12 BER) Pmax - 8.0 - - dBm
Increasing Light Input Plos+ - - - 28.0
LOS Thresholds dBm
Decreasing Light Input Plos- - 45.0 - -
Increasing Light Input t_loss_off - - 100
LOS Timing Delay s
Decreasing Light Input t_loss_on 2.3 - 100
LOS Hysteresis - 0.5 1.5 - dB
Wavelength of Operation 1260 - 1570 nm
Receiver Reflectance - - - -27.0 dB
1
Specified through EOL.
2
Measured with 223-1 PRBS.
3
Measured with 27-1 PRBS.

Laser Safety: All transceivers are Class I Laser prod- Oplink Communications, Inc.
ucts per FDA/CDRH and IEC-60825 standards. They DATE OF MANUFACTURE:
must be operated under specified operating condi-
tions. This product complies with
21 CFR 1040.10 and 1040.11
Meets Class I Laser Safety Requirements

Oplink Communications, Inc. 2 21737-0456. v08. 2010.05.11


TRPW48L2/E2 DWDM
Transmitter Performance Characteristics (Over Operating Case Temperature. VCC = 3.13 to 3.47V)

Parameter Symbol Minimum Typical Maximum Units


Input Voltage Swing (TD+ & TD-) 1 VPP-DIF 0.35 - 1.75 V
Input HIGH Voltage (TX Disable) 2
VIH 2.0 - VCC V
Input LOW Voltage (TX Disable) 2 VIL 0 - 0.8 V
Output HIGH Voltage (TX Fault) 3 VOH 2.0 - VCC + 0.3 V
Output LOW Voltage (TX Fault) 3
VOL 0 - 0.8 V
1
Differential peak-to-peak voltage.
2
There is an internal 4.7 to 10k pull-up resistor to VccT.
3
Open collector compatible, 4.7 to 10k pull-up resistor to Vcc (Host Supply Voltage).

Receiver Electrical Interface (Over Operating Case Temperature. VCC = 3.13 to 3.47V))

Parameter Symbol Minimum Typical Maximum Units


Output Voltage Swing (RD+ & RD-) 1 VPP-DIF 0.40 - 1.75 V
Output HIGH Voltage (LOS) 2
VOH VCC - 1.3 - VCC + 0.3 V
Output LOW Voltage (LOS)) 2
VOL 0 - 0.5 V
1
Differential peak-to-peak voltage across external 100 load.
2
Open collector compatible, 4.7 to 10k pull-up resistor to Vcc (Host Supply Voltage).

Electrical Power Supply Characteristics (Over Operating Case Temperature. VCC = 3.13 to 3.47V))
Parameter Symbol Minimum Typical Maximum Units
Supply Voltage VCC 3.13 3.3 3.47 V
Commercial - - 350
Supply Current ICC mA
Extended - - 430

Module Definition
MOD_DEF(0) MOD_DEF(1) MOD_DEF(2)
Interpretation by Host
pin 6 pin 5 pin 4

TTL LOW SCL SDA Serial module definition protocol

Electrical Pad Layout Host Board Connector Pad Layout

20 TX GND 1 TX GND
20
19 TD- (TX DATA IN-) 2 TX Fault 1
19
18 TD+ (TX DATA IN+) 3 TX Disable 2
18
17 TX GND 4 MOD_DEF(2) 3
17
16 VccTX 5 MOD_DEF(1) 4
Toward 16
15 VccRX 6 MOD_DEF(0) Bezel 5
15
14 RX GND 7 NO CONNECTION 6 Toward
14 ASIC
13 RD+ (RX DATA OUT+) 8 LOS 7
13
12 RD- (RX DATA OUT-) 9 RX GND 8
12
11 RX GND 10 RX GND 9
11
10
Bottom of Board
Top of Board
(as viewed thru top of board)

Oplink Communications, Inc. 3 21737-0456. v08. 2010.05.11


TRPW48L2/E2 DWDM
Example of SFP host board schematic

Vcc
3.3V
1H coil or ferrite bead
(<0.2 series resistance)
Vcc R R R R
3.3V 16
+
10 0.1 0.1 2 TX Fault
8 LOS
15
+
10 0.1 TRPW48 4 MOD_DEF(2)
DWDM 5 MOD_DEF(1)
MOD_DEF(0)
TX Disable 3 6
100
18 RX DATA OUT+
TX DATA IN+ 13
to 50 load

19 RX DATA OUT-
TX DATA IN- 12 to 50 load
1, 9,10,11,14,17,20

R: 4.7 to 10k
CAP Values in F

Application Notes
Electrical interface: All signal interfaces are compliant with Serial Identification and Monitoring: The module definition of
the SFP MSA specification. The high speed DATA interface is SFP is indicated by the three module definition pins, MOD_DEF(0),
differential AC-coupled internally with 0.1F and can be directly MOD_DEF(1) and MOD_DEF(2). Upon power up, MOD_DEF(1:2)
connected to a 3.3V SERDES IC. All low speed control and sense appear as NC (no connection), and MOD_DEF(0) is TTL LOW.
output signals are open collector TTL compatible and should be When the host system detects this condition, it activates the serial
pulled up with a 4.7 - 10k resistor on the host board protocol (standard two-wire I2C serial interface) and generates
Loss of Signal (LOS): The Loss of Signal circuit monitors the the serial clock signal (SCL). The positive edge clocks data into
level of the incoming optical signal and generates a logic HIGH the EEPROM segments of the SFP that are not write protected,
when an insufficient photocurrent is produced. and the negative edge clocks data from the SFP.
TX Start-up: During power up or hot plugging the DWDM The serial data signal (SDA) is for serial data transfer. The host
SFP module will initially set the TX to the correct operating uses SDA in conjunction with SCL to mark the startand end of
temperature. Depending on the ambient temperature this may serial protocol activation. The supported monitoring functions
take several seconds to 1 minute. When the Tx has reached are internal temperature, supply voltage, bias current, transmitter
the required temperature the Tx is switched on and active. At power, average receiver signal, all alarms and warnings and
this point the Tx is guaranteed to be within +/-0.2nm of the software monitoring of TX Fault/LOS. The device is internally
appropriate ITU wavelength and will settle to +/-0.05nm within calibrated.
the time limit set by the MSA. The data transfer protocol and the details of the mandatory and
TX_Fault: The output indicates LOW when the transmitter is vendor specific data structures are defined in the MSA.
operating normally, and HIGH with a laser fault including laser Power supply and grounding: The power supply line should be
end-of-life. TX Fault is an open collector/drain output that should well-filtered. All 0.1F power supply bypass capacitors should
be pulled up with a 4.7 - 10k resistor on the host board. TX Fault be as close to the transceiver module as possible.
is latched per SFP MSA.
TX_Disable: When the TX Disable pin is at logic HIGH, the
transmitter optical output is disabled (less than -45dBm).

Oplink Communications, Inc. 4 21737-0456. v08. 2010.05.11


TRPW48L2/E2 DWDM

Package Outline

2.224
56.50 REF

.601 .539
15.25 13.70

FRONT EDGE OF
TRANSCEIVER CAGE
.080 1.874
.246
2 47.60REF
6.25 REF

.335 .339 .375


8.50 8.6 MAX 9.53

.064
.539 .004
1.62
13.7 0.1

1.646 .006
41.8 0.15

Dimensions in mm [inches]
1.772 .008 Default tolerances:
45 0.2 X.XX 0.1 [.004]
X.X 0.25 [.01]

Ordering Information for 80km Distance

Model Name Center ITU


Wavelength
Commercial Temp. Extended Temp. Wavelength Frequency Distance
Reference
-5C to +70C -5C to +85C (nm) (THz)

TRPW48L2OB610 TRPW48L2OE610 1528.77 196.1 61 80km


TRPW48L2OB600 TRPW48L2OE600 1529.55 196.0 60 80km
TRPW48L2OB590 TRPW48L2OE590 1530.33 195.9 59 80km
TRPW48L2OB580 TRPW48L2OE580 1531.12 195.8 58 80km
TRPW48L2OB570 TRPW48L2OE570 1531.90 195.7 57 80km
TRPW48L2OB560 TRPW48L2OE560 1532.68 195.6 56 80km
TRPW48L2OB550 TRPW48L2OE550 1533.47 195.5 55 80km
TRPW48L2OB540 TRPW48L2OE540 1534.25 195.4 54 80km
TRPW48L2OB530 TRPW48L2OE530 1535.04 195.3 53 80km
TRPW48L2OB520 TRPW48L2OE520 1535.82 195.2 52 80km
TRPW48L2OB510 TRPW48L2OE510 1536.61 195.1 51 80km
TRPW48L2OB500 TRPW48L2OE500 1537.40 195.0 50 80km
TRPW48L2OB490 TRPW48L2OE490 1538.19 194.9 49 80km
TRPW48L2OB480 TRPW48L2OE480 1538.98 194.8 48 80km
TRPW48L2OB470 TRPW48L2OE470 1539.77 194.7 47 80km
TRPW48L2OB460 TRPW48L2OE460 1540.56 194.6 46 80km
TRPW48L2OB450 TRPW48L2OE450 1541.35 194.5 45 80km
TRPW48L2OB440 TRPW48L2OE440 1542.14 194.4 44 80km
TRPW48L2OB430 TRPW48L2OE430 1542.94 194.3 43 80km

Oplink Communications, Inc. 5 21737-0456. v08. 2010.05.11


TRPW48L2/E2 DWDM

Ordering Information (cont.)


Model Name Center ITU
Wavelength
Commercial Temp. Extended Temp. Wavelength Frequency Distance
Reference
-5C to +70C -5C to +85C (nm) (THz)

TRPW48L2OB420 TRPW48L2OE420 1543.73 194.2 42 80km


TRPW48L2OB410 TRPW48L2OE410 1544.53 194.1 41 80km
TRPW48L2OB400 TRPW48L2OE400 1545.32 194.0 40 80km
TRPW48L2OB390 TRPW48L2OE390 1546.12 193.9 39 80km
TRPW48L2OB380 TRPW48L2OE380 1546.92 193.8 38 80km
TRPW48L2OB370 TRPW48L2OE370 1547.72 193.7 37 80km
TRPW48L2OB360 TRPW48L2OE360 1548.51 193.6 36 80km
TRPW48L2OB350 TRPW48L2OE350 1549.32 193.5 35 80km
TRPW48L2OB340 TRPW48L2OE340 1550.12 193.4 34 80km
TRPW48L2OB330 TRPW48L2OE330 1550.92 193.3 33 80km
TRPW48L2OB320 TRPW48L2OE320 1551.72 193.2 32 80km
TRPW48L2OB310 TRPW48L2OE310 1552.52 193.1 31 80km
TRPW48L2OB300 TRPW48L2OE300 1553.33 193.0 30 80km
TRPW48L2OB290 TRPW48L2OE290 1554.13 192.9 29 80km
TRPW48L2OB280 TRPW48L2OE280 1554.94 192.8 28 80km
TRPW48L2OB270 TRPW48L2OE270 1555.75 192.7 27 80km
TRPW48L2OB260 TRPW48L2OE260 1556.55 192.6 26 80km
TRPW48L2OB250 TRPW48L2OE250 1557.36 192.5 25 80km
TRPW48L2OB240 TRPW48L2OE240 1558.17 192.4 24 80km
TRPW48L2OB230 TRPW48L2OE230 1558.98 192.3 23 80km
TRPW48L2OB220 TRPW48L2OE220 1559.79 192.2 22 80km
TRPW48L2OB210 TRPW48L2OE210 1560.61 192.1 21 80km
TRPW48L2OB200 TRPW48L2OE200 1561.42 192.0 20 80km
TRPW48L2OB190 TRPW48L2OE190 1562.23 191.9 19 80km
TRPW48L2OB180 TRPW48L2OE180 1563.05 191.8 18 80km
TRPW48L2OB170 TRPW48L2OE170 1563.86 191.7 17 80km

Ordering Information for 120km Distance


Model Name Center ITU
Wavelength
Commercial Temp. Extended Temp. Wavelength Frequency Distance
Reference
-5C to +70C -5C to +85C (nm) (THz)

TRPW48E2OB610 TRPW48E2OE610 1528.77 196.1 61 120km


TRPW48E2OB600 TRPW48E2OE600 1529.55 196.0 60 120km
TRPW48E2OB590 TRPW48E2OE590 1530.33 195.9 59 120km
TRPW48E2OB580 TRPW48E2OE580 1531.12 195.8 58 120km
TRPW48E2OB570 TRPW48E2OE570 1531.90 195.7 57 120km
TRPW48E2OB560 TRPW48E2OE560 1532.68 195.6 56 120km
TRPW48E2OB550 TRPW48E2OE550 1533.47 195.5 55 120km
TRPW48E2OB540 TRPW48E2OE540 1534.25 195.4 54 120km
TRPW48E2OB530 TRPW48E2OE530 1535.04 195.3 53 120km
TRPW48E2OB520 TRPW48E2OE520 1535.82 195.2 52 120km
TRPW48E2OB510 TRPW48E2OE510 1536.61 195.1 51 120km
TRPW48E2OB500 TRPW48E2OE500 1537.40 195.0 50 120km

Oplink Communications, Inc. 6 21737-0456. v08. 2010.05.11


TRPW48L2/E2 DWDM

Ordering Information (cont.)

Model Name Center ITU


Wavelength
Commercial Temp. Extended Temp. Wavelength Frequency Distance
Reference
-5C to +70C -5C to +85C (nm) (THz)

TRPW48E2OB490 TRPW48E2OE490 1538.19 194.9 49 120km


TRPW48E2OB480 TRPW48E2OE480 1538.98 194.8 48 120km
TRPW48E2OB470 TRPW48E2OE470 1539.77 194.7 47 120km
TRPW48E2OB460 TRPW48E2OE460 1540.56 194.6 46 120km
TRPW48E2OB450 TRPW48E2OE450 1541.35 194.5 45 120km
TRPW48E2OB440 TRPW48E2OE440 1542.14 194.4 44 120km
TRPW48E2OB430 TRPW48E2OE430 1542.94 194.3 43 120km
TRPW48E2OB420 TRPW48E2OE420 1543.73 194.2 42 120km
TRPW48E2OB410 TRPW48E2OE410 1544.53 194.1 41 120km
TRPW48E2OB400 TRPW48E2OE400 1545.32 194.0 40 120km
TRPW48E2OB390 TRPW48E2OE390 1546.12 193.9 39 120km
TRPW48E2OB380 TRPW48E2OE380 1546.92 193.8 38 120km
46335 Landing Pkwy Fremont, CA 94538 Tel: (510) 933-7200 Fax: (510) 933-7300 Email: Sales@Oplink.com www.oplink.com

TRPW48E2OB370 TRPW48E2OE370 1547.72 193.7 37 120km


TRPW48E2OB360 TRPW48E2OE360 1548.51 193.6 36 120km
TRPW48E2OB350 TRPW48E2OE350 1549.32 193.5 35 120km
TRPW48E2OB340 TRPW48E2OE340 1550.12 193.4 34 120km
TRPW48E2OB330 TRPW48E2OE330 1550.92 193.3 33 120km
TRPW48E2OB320 TRPW48E2OE320 1551.72 193.2 32 120km
TRPW48E2OB310 TRPW48E2OE310 1552.52 193.1 31 120km
TRPW48E2OB300 TRPW48E2OE300 1553.33 193.0 30 120km
TRPW48E2OB290 TRPW48E2OE290 1554.13 192.9 29 120km
TRPW48E2OB280 TRPW48E2OE280 1554.94 192.8 28 120km
TRPW48E2OB270 TRPW48E2OE270 1555.75 192.7 27 120km
TRPW48E2OB260 TRPW48E2OE260 1556.55 192.6 26 120km
TRPW48E2OB250 TRPW48E2OE250 1557.36 192.5 25 120km
TRPW48E2OB240 TRPW48E2OE240 1558.17 192.4 24 120km
TRPW48E2OB230 TRPW48E2OE230 1558.98 192.3 23 120km
TRPW48E2OB220 TRPW48E2OE220 1559.79 192.2 22 120km
TRPW48E2OB210 TRPW48E2OE210 1560.61 192.1 21 120km
TRPW48E2OB200 TRPW48E2OE200 1561.42 192.0 20 120km
TRPW48E2OB190 TRPW48E2OE190 1562.23 191.9 19 120km
TRPW48E2OB180 TRPW48E2OE180 1563.05 191.8 18 120km
TRPW48E2OB170 TRPW48E2OE170 1563.86 191.7 17 120km

Oplink can provide a remarkable range of customized optical solutions. For detail, please contact Oplinks Sales
and Marketing for your requirements and ordering information (510) 933-7200 or Sales@oplink.com.

Oplink Communications, Inc. reserves the right to make changes in equipment design or specifications without notice. Information supplied by Oplink Commu-
nications, Inc. is believed to be accurate and reliable. However, no responsibility is assumed by Oplink Communications, Inc. for its use nor for any infringements
of third parties, which may result from its use. No license is granted by implication or otherwise under any patent right of Oplink Communications, Inc.
2010, Oplink Communications, Inc. 7 21737-0456. v08. 2010.05.11

You might also like