Features at a Glance:
True-rms ac and dc voltage measurement
True-rms AC current
DC current
Resistance
Continuity beeper
Max Hold
Safety-designed hand guard
Carrying case
Jaws accept one 750 MCM (1.2" (3 cm))
cable or two 500 MCM (.98" (2.46 cm))
cables up to 38 mm (1.5" in diameter)
DC current zero control for nulling out
jaw/sensor offset
Easy, single-handed operation
Easy-view 2000 count digital display
Continuity beeper
Protective soft carrying case and TL75 test
leads included
Sleep mode extends battery life
CAT III 600V
Independently tested and approved for UL
3111, CSA 22.2 1010.1 1992 and TUV to
EN61010-1:1993
All
All
Technical Specifications
General Specifications
Technical Specifications
DC Current Range: 1000A, 200A
Resolution: 1A, .1A
Accuracy: 0-600A: (1.9%+4), 600-1000A:(3%+3),
0-200A: (1.9%+7)
DC Volts Range: 600V/200V
Resolution: 1V/.1V
Accuracy: (1.0%+3)
AC Current Range: 600A/200A
(45-400Hz) Resolution: 1V/.1V
Accuracy: (2%+3)/(2%+5)
Crest Factor: Between 2 and 3 add 2% of reading
AC Volts (45-400Hz) Range: 600V/200V
Resolution: 1V/.1V
Accuracy: (1.5%+3)
Crest Factor: <=3 (pk voltage 933V)
Ohms Range: 200 Ohms
Resolution: 0.1 Ohms
Accuracy: +(1.2%+5)
Crest Factor: NA
General Specifications
RF field RF field = <=1V/m, total accuracy = specified accuracy
RF field = 3V/m, total accuracy = specified accuracy + 4% of
range
Operating -10C to 50C (14F to 122F)
temperature
Battery life 60 hours continuous, alkaline, sleep mode