You are on page 1of 1

COAL NOZZLE

JSW Abhishek Vardhman Grasim SPB


Original Modified
Original Original Original Original Modified Proposed -1 Proposed -2 Option -1 Option -2 Option -3 Option -4 Option -5
Fuel transport line OD 127 127 168.3 141.3 141.3 127 127 127 127 127 127 127 127 127
Fuel transport line THK ( mm ) 8 8 7.11 6.55 6.55 8 8 8 8 8 8 8 8 8
Fuel transport line area ( sq mm ) 9676.89 9676.89 18645.86 12908.21 12908.21 9676.89 9676.89 9676.89 9676.89 9676.89 9676.89 9676.89 9676.89 9676.89
Coal nozzle size ( mm ) 4" 4" 6" 5" 5" T nozzle 4" 4" 4" 5" 5" 5" 5" 5"
Inlet pipe OD ( mm ) 127 127 168.3 141.3 141.3 127 127 127 127 141.3 141.3 141.3 141.3 141.3
inlet pipe thk ( mm ) 8 8 7.11 6 6.02 8 8 8 8 6.02 6.02 6.02 6.02 6.02
Inlet area ( sq mm ) 9676.89 9676.8918645.86 13130.67 13122.55 9676.89 9676.89 9676.89 9676.89 13122.55 13122.55 13122.55 13122.55 13122.55
Outlet height ( mm ) 26 26 35 43 35 2 X inlet 26 40 40 50 50 50 50 50
Outlet circum area ( sq mm ) 10373.54 10373.54
18505.55 19088 15536.75 19353.78 10373.54 15959.29 15959.29 22195.35 22195.35 22195.35 22195.35 22195.35
Support lug width ( mm ) 20 20 20 20 20 - 20 20 20 20 20 20 20 20
No of supp lug ( Nos ) 3 3 3 3 3 - 3 3 3 3 4 4 4 4
Actual oulet circum area ( sq mm ) 8813.54 8813.54 16405.55 16508 13436.75 19353.78 8813.54 13559.29 13559.29 19195.35 18195.35 18195.35 18195.35 18195.35
C.N .Inlet to outlet area rati( % ) 91.08 91.0887.98 125.72 102.39 200.00 91.08 140.12 140.12 146.28 138.66 138.66 138.66 138.66
FT pipe to outlet area (%) 91.08 91.0887.98 127.89 104.09 200.00 91.08 140.12 140.12 198.36 188.03 188.03 188.03 188.03
Top cover dia ( mm ) 230 270 300 270 300 - 230 270 300 300 300 300 300 300
Bolted /
Top cover attachment Welded Welded Welded Welded Welded Welded Welded Welded Welded Bolted Bolted Bolted Bolted
Welded
Top cover material specn SS 304 SS 310 SS 304 SS 304 SS 304 SS 304 SS 304 SS 310 SS 310 SS 310 SS 310 SS 310 SS 310 SS 310
Coal nozzle replace Note -1 Note -1 Note -2 Note -2 Note -2 Note -3 Note -2 Note -2 Note -2

Notes
1 . Can be replaced from bottom side
2 . Cover Shall be fitted from top side
3 . Top cover shall be fitted from top side and the flange item no. 5 & 6 shall be welded with pipe at site

Option -1 Option -2 Option -3 Option -4 Option -5


Welded type bolted type bolted type bolted type bolted type
As per our existing type Outlet disc as per SPB having No outlet disc No outlet disc No outlet disc
cooling air for bolt & nut also no cooling air for bolt & nut
No annular pipe ( If we provide inner pipe as
SS310 , we can remove the outer pipe )

You might also like