You are on page 1of 3

NH-58 Design of Seismic Arrestor

DESIGN OF SEISMIC ARRESTOR

# Design in Transverse Direction

Load Calculation ( Unfactored Loads )


Dead Load coming from Super-Str = 5409.6 kN
SIDL = 1787 kN
Live Load coming from Super-Str = 224.93 kN
(only 20% Live Load is to be Considered in the transverse seismic calculation)

Sub-Total of Vertical Loads = 7421.5 kN

( Factored Loads ) Load Factor ULS


Dead Load coming from Super-Str = 1.35 x 7302.96 kN
SIDL = 1.75 x 3127.25 kN
Live Load coming from Super-Str = 1.50 x 337.395 kN

Sub-Total of Vertical Loads = 10767.6 kN

Seismic Co-efficient
for Zone V Zone Factor is = 0.360
Importance of Bridge Important Bridges = 1.200
Response reduction factor, R = 1.000
Average Response Acceleration Co-efficient = 2.500
Horizontal Seismic Co-efficient = 0.540
(Ah)
Z I Sa
Ah x x
2 R g

Design Data
Assuming the Size of Longitudinal Arrestor
Plan dimension ( b x D )
900 x 900 mm
Top Width of Arrestor in Plan = 450 mm
Height of Seismic Arrestor L = 1100 mm
Clear Cover provided C.C. = 40 mm
Total Depth for Section at Height L1 = 700.00 mm
Effective depth of Section d' = 394 mm
Dist of load from face a = 489 mm

Allowable Stress for M 35 Concrete = 11.67 MPa


Concrete Cylindrical strength fc' = 29.05 MPa
Allowable Stress for Fe 500 D Steel = 435.0 MPa
Conc. Cast Monolithically across interface = 1.40

1 of 3 CH-429+650,452+050
NH-58 Design of Seismic Arrestor

Check for Corbel


450

Tranverse Direction
900

900

Longitudinal Direction L1 = 488.9 mm


L1 / D = 1.0864 > 1.000
Hence this is not a Corbel
400

1100
900 L1

Design Calculation
The Seismic Arrestor is designed for the seismic force transmitted to it from Super-Structure.
Design Horizontal Force Hu = 5814.5 kN
Design Vertical Force Vu = 0.0 kN
(20% Design Horizontal Force) min. H u = 1162.9 kN

No of Seismic Arrestor = 1

Loads on each Arrestor in the Transverse Direction


Ultimate Shear Force Fu = 5814.5 kN
Horizontal Force Hu = 1162.9 kN
Ultimate Flexural Moment Mu = 2907.8 kNm

Reinforcement Calculation
A vf 2
Shear Friction Reinforcement = 9547.6 mm
At 2
Direct Tension Reinforcement = 2673.3 mm
Af 2
Flexural Tension Reinforcement = 18850.9 mm
2
Af + At = 21524.2 mm
2
(2/3 x Avf) + At = 9038.4 mm
2
(0.04 x fc' / fsy) x b x d' = 824.1 mm
2
Total Primary Tensile Reinforcement As = 21524.2 mm

0.5 x Af = 9425.5 mm2


0.33 x Avf = 3179.4 mm2
Cross sectional area of stirrups Ah = 9425.5 mm2

2 of 3 CH-429+650,452+050
NH-58 Design of Seismic Arrestor

Reinforcement
As 2
Total Primary Tensile Reinforcement = 21524.2 mm
So, Provide 32 Bar - 15 No.s in 2 Layers
in Each Layer

Ah 2
Cross sectional area of stirrups = 9425.5 mm
Required Spacing s = 113.3 mm
So, Provide 6 Legged 16 Bar @ 100 spacing c/c

Check for Shear


Ultimate Shear Force Vu = 5814.5 kN
Shear Stress tv = 14.357 N/mm2
As per Table 12B of IRC:21-2000,
Permissble Stresss for 2.9787 % of steel for M 35 = 0.6674 N/mm2

As per Clause 304.7.1.3.3 of IRC:21-2000, the permissible stress in concrete can be increased by a
Factor of,
= 1+ 5x P d= 3.0510 <= 1.500
Ag x fck therfore d 1.5000
Maximum Allowable Shear Stress on block = 1.0012 N/mm2
< 14.357
Hence, Shear Reinforcement is Required

Design Shear Force V ed = 5409.0 kN


Required Shear Friction Reinforcement A sw = 8881.8 mm2
8881.8 < 9547.630
Hence, Shear Strrips are Sufficient

3 of 3 CH-429+650,452+050

You might also like