You are on page 1of 2

Control Valve Data Sheet no. 16101729.

10

1A customer: Diverse Kunden Indien no.: 99998


2A plant ABB ALAMSAS AGIR SANAYI A.S.

3A pos. / marking: 1 ---


4 quantity: 1 High pressure min flow valve DN 8"
5 type: 1315-68 globe valve
6 body made of: SA217 WC9
7 installation: horizontal
8A connection: welded ends SA217WC9, AE 219,1 x 32 mm
11A Body class #2500
mod. 794, 263787 (229495)
12A trim: *** 7-stage pressure reducing ***
1 perforated cage in the inlet
6 perforated discs of 1.4122
(X35CrMo17)
balanced plug (turcon-glydring)
1 perforated cage in the outlet
jamed seat made of 1.4122 hardened
(X35CrMo17)
13A stem packing: graphite/K80S

14A mounting (pneumatic): for:


pneumatic actuator, type PA-N 2160-0-100
mode of operation: air closes/spring opens
spring range 1,5 - 3,0 (eff. 1,5 - 1,95)
supply air 5 kg/cm
handwheel top, laterally
Tubing made of CU

air set with filter SMC, type EAW 4000-F04D-G1/2


2 limit switches (1 open, 1 close)
Siemens 3SE5 112 - 0L E01

actuator will be mounted on site

15 medium: feedwater

16 load conditions: Q p1 p2 p t1 kv
(m/h) (kg/cm) (kg/cm) (kg/cm) (C) (m/h)
hot 400,0 280,0 10,0 270,0 160,5 23,6
cold 105,0 23,0 4,0 19,0 40,0 24,2

17 cv : 33,5 characteristic: on/off


18 kvs : 29
19 seat 70 mm stroke: 30 mm
20 p actuator : 280 kg/cm
21 stress calculation: inlet 320 kg/cm / 190 C outlet 320 kg/cm / 190 C
22A techn. terms of delivery: American valve specification ANSI B16.34-2007
23 acceptance certificate: Inspection certificate 3.1 acc. to EN 10204 and IBR IIIC
24A inspection: Hydrostatic Pressure Test
Seat Leakage Test
Assembled Valve Test
cv-test

created 06.07.2016 Heike Boeckhaus / PT Phone / Fax: +49(0)5207/8903-1106 / -2106 V1 06.07.2016 page 1 of 2
Control Valve Data Sheet no. 16101729.10

25 noise: <85dB(A) w/o insolation


27 direction of flow: on the plug
28A varnish: type 1815 synthetic resin zinc dust, grey, up to 200 C
29 leakage class: FCI 70-2-2003 class V
30A remark: Replacement for HORA ref. 10208445-1.10
31 identification plate: english documentation: english
32 IOM manual: english
35 packing: sea freight
36 installation: installation indoor

created 06.07.2016 Heike Boeckhaus / PT Phone / Fax: +49(0)5207/8903-1106 / -2106 V1 06.07.2016 page 2 of 2