Professional Documents
Culture Documents
FIRST RELEASE
2 PLY 2x12 MIN WITH 12"
HEADER REQUIREMENTS ROUGH OPENING HEIGHT SHEATHING BETWEEN PLYS
ROUGH OR 2 PLY 13 4"x117 8" MIN. LVL
4 MODEL H INSTALL SDS1 4"x312"
OPENING (2 PLY LVL SHOWN)
No. CURB SCREWS. SEE SIDE VIEWS
HEIGHT
FOR NUMBER & SPACING
SSW12x7 512" 7' - 112" NOTE: (SCREWS BY INSTALLER)
SSW15x7 MULTI-PLY HEADERS MAY BE
REGISTERED DESIGN PROFESSIONAL
9/21/2009
4/16/2014
8/08/2016
SSW18x7 6" 7' - 2" USED WITH STEEL STRONG-
IS PERMITTED TO MODIFY DETAILS
1 21"
WALL FOR WIND DESIGNS OR
FOR SPECIFIC CONDITIONS.
SSW12x7.4 IN SEISMIC DESIGN CATEGORIES
SSW15x7.4 0" 7' - 1 12" A-C (IBC & IRC) ONLY
SSW18x7.4
PORTAL STRAP AND SDS14"x312" SCREWS
#14 SELF-DRILLING SCREWS 512" 8' - 2 3 4" PROVIDED WITH WALL
SSW12x8 NOTE:
2
(PROVIDED WITH SSWP-KT) SSW15x8 PORTAL STRAP NOT SHOWN
1 SSW
SSW18x8 6" 8' - 3 4" FOR CLARITY. REFER TO
SSW MULTI-PLY HEADER CROSS SECTION
DETAIL 4/SSW4 FOR PORTAL
LSTA24 STRAP (MIN.) HEADER SUPPORT POST 1. THE HEIGHT OF THE GARAGE CURB STRAP INSTALLATION.
AT BEAM TO POST (BY DESIGNER) ABOVE THE GARAGE SLAB IS CRITICAL
1" MIN.
FOR THE ROUGH HEADER OPENING AT TYP. 2"
GARAGE RETURN WALLS.
2" 3
2. SHIMS ARE NOT PROVIDED WITH 1 INSTALL SDS 1/4"x3 1/2" SCREWS
ROUGH 8' MIN. 16' - 4" MAX.
STEEL STRONG-WALL. HORIZONTALLY THROUGH LVL OR
OPENING
3. FURRING DOWN GARAGE HEADER MAY 2 x LUMBER HEADER PLYS. 4 SCREWS
HEIGHT 4
BE NECESSARY FOR CORRECT ROUGH TOTAL FOR SSW12.6 SCREWS TOTAL
OPENING HEIGHT. FOR SSW15, SSW18, SSW21 AND SSW24.
1 21"
HOLDOWN SHOWN WITH WALL
(EXTERIOR FACE) (1000lb UPLIFT CAPICITY MIN.)
3 3 FASTEN PLYS TOGETHER WITH 16d
COMMON NAILS AT 16" O.C. ALONG EACH
COLUMN BASE EDGE OF BEAM.
SIM. (BY DESIGNER) 1 2
ENGINEERED DESIGNS
GARAGE RETURN WALLS.
2. SHIMS ARE NOT PROVIDED WITH
ROUGH 8' MIN. 16' - 4" MAX.
STEEL STRONG-WALL. NOTES 6
3. FURRING DOWN GARAGE HEADER MAY
OPENING
BE NECESSARY FOR CORRECT ROUGH
HEIGHT
OPENING HEIGHT.
STEEL STRONG-WALL
(EXTERIOR FACE)
3 3
SIM. SIM.
H H
CURB CURB
NOTE:
LOAD PATH DESIGN AND FULL LENGTH GARAGE HEADER
PLACE SSW PANEL OVER DETAILS ABOVE HEADER TO (BY DESIGNER)
THE ANCHOR BOLTS AND BE PROVIDED BY DESIGNER. MINIMUM SIZE SHALL BE:
SECURE WITH HEAVY 4x12 DFL
HEX NUTS. (PROVIDED) 3 1/8X12 GLB
USE 11 4" WRENCH / SOCKET FOR 3/4" NUT ALTERNATE HEADERS ALLOWED.
FIELD NAIL PORTAL STRAP (BY DESIGNER)
USE 15 8" WRENCH / SOCKET FOR 1" NUT
NUTS SHALL BE SNUG TIGHT. TO HEADER WITH (10) 10dX212 MIN. NAILS. FOR MUITI-PLY HEADER REQUIREMENTS
FASTEN STRAP TO PANEL
DO NOT USE AN IMPACT WRENCH. 5
WITH (4) #14 SELF-DRILLING SCREWS. SEE
(SCREWS PROVIDED WITH SSWP-KT)
1 4 ALIGN NOTCH ON STRAP
SEE TO FOR WITH BOTTOM OF HEADER.
SDS1 4"X312" SCREWS
ANCHORAGE SOLUTIONS (PROVIDED) 7/8" MAX. SHIM ALLOWED BETWEEN
PANEL AND BEAM (NOT SHOWN).