a.1.8 Flashing
Extra Over a.1 Providing & fixing 1.2mm thk. G.I. sheet flashing with sealing by silicone of approved make to the
structure and fixed with SS 304 hardware. All prices to be inclusive of all Taxes, Statutory requirements, etc. RMT 522.00 522.00
Total
Total
a.5.2 Glass
a.5.2.1 Option-1 - Dark Blue -Glaverbel Make- 6mm Sunergy Dark Blue + 12mm air gap + 6mm Clear low-e (SHGC-
SQM 5,310.00 5,310.00
0.25 , 35% VLT & U- 1.6 W/Sqm K). All prices to be inclusive of all Taxes, Statutory requirements, etc.
a.5.2.2 Option-2 - Blue Green -Saint Goblin Make-ST450-6mm #2 low-E + 12mm Airgap+6mm #3 low-E Glass (SHGC-
SQM 5,220.00 5,220.00
0.25 , 35% VLT & U- 1.77 W/Sqm K). All prices to be inclusive of all Taxes, Statutory requirements, etc.
a.5.2.3 Option-3 - Blue - Emirates Glass-SOLITE-STRATUS 39/23-6mm Low-E + 12mm air gap + 6mm Clear (SHGC-
SQM 5,508.00 5,508.00
0.23 , 39% VLT & U- 1.3 W/Sqm K). All prices to be inclusive of all Taxes, Statutory requirements, etc.
a.5.3 Flashing
Extra Over a.4 Providing & fixing 1.2mm thk. G.I. sheet flashing with sealing by silicone of approved make to the
structure and fixed with SS 304 hardware. All prices to be inclusive of all Taxes, Statutory requirements, etc. RMT 1,206.00 1,206.00
a.6.2 Design,fabricate, package, deliver (to Job site) and installation of S.S. 316 spider of approved make as per
structural calculations & *13.52mm Laminated Glass comprising of 6mm thk. Heat Strengthened Glass + 1.52
Clear PVB + 6mm thk. Clear Heat Strengthened Glass (downside) as per concept dwgs. The detailed SQM 12,510.00 12,510.00
specifications including erection & removal of scaffolding, cleaning the Facade & testing. All prices to be
inclusive of all Taxes, Statutory requirements, etc. Only Glass area will be measured & paid for.
Certification will be based on actual measurement at site .
Total
Total
B Window/Ventilator/Louvers
Design, fabricate, package, deliver (to Job site) and install Fixed / operable windows comprising 6mm thk high
performance glass. The contractor shall be follow the conceptual system for rates. The glass panels will be
mechanically fixed to the aluminium main frame with alum beading from inside and frame shall fixed to steel /
conc with approved standard accessories. Silicone specifications are highlighted in the specifications manual.
All aluminium extruded profiles shall be confirming to alloy 6063 T6. All exposed Aluminium profiles shall be
anodized with a minimum thickness of 25 microns and shade shall be as per architect's approval. The window
shall be sealed to the host structure and not adjoining materials with approved water proofing membrane and
insulation to prevent sound transmission.The System and glass shall be designed to withstand wind pressure of
1.56 KPA at all levels, elevation & heights. The anchoring / bracing of the window system to the RCC slab /
beams / columns shall be done with non-corrosive galvanized brackets of approved design (80-90 micron
thickness) and including providing teflon shims of various thickness to adjust the beam level / line variations
fixed with SS dash fasteners Hilti , Fisher or equivalent to withstand the dead load of the windows as well as
stresses due to wind pressure etc. Anchorage: Allow 3 dimensional movements in anchorage (bracket) design
to absorb +/-40 mm host structure tolerances.All screws, washers used shall be only stainless steel of 304 grade
and Through Bolts , Nuts & anchors used shall be only stainless steel of 304 grade.The contractor must design
the system as per the prevalent site conditions and building elevation profiles. No extra claims shall be
entertained at any stage for aluminium profile/sheet wall thickness and size dimensions. Quote in compliance
with Concept Drawings and specifications noted herein including erection & removal of scaffolding, cleaning the
Facade. Rates also should include lab performance testing, site performance testing, mockup prior to start the
work. The Contractor must quote rates accordingly. All prices to be exclusive of all Taxes, Statutory
requirements, etc.
c.1.2 Supply & installation of pre cast concrete panel (Gray/Approved) on soffit / ceilings / roofs as per the
SQM NA NA
apecifications
c.1.3 Supply & installation of pre cast concrete panel (Gray/Approved) on coping / projected fins as per the
SQM NA NA
apecifications
c.1.4 Supply & installation of pre cast concrete panel tiles (Gray/Approved) on internal walls / Corridors as per the
SQM NA NA
apecifications
c.1.5 Supply & installation of fluted pre cast concrete panel tiles (Gray/Approved) on internal walls / Corridors as per
SQM NA NA
the apecifications
Fire Stopper
c.3 Extra Over c.1.1 Providing & fixing rock wool (Density : 100 Kg. / M3) insulation of approved sample / make
enclosed in a 2mm thk. G.I. sheet support sealed with fire stop silicone of approved make to the structure and
fixed with SS 304 hardware, fire rated Anchors of Hilt/Fischer make as per concept drawings. All prices to be RMT 522.00 522.00
inclusive of all Taxes, Statutory requirements, etc.
Flashing
c.4 Extra Over c.1.1 & c.1.2 Providing & fixing 1.2mm thk. G.I. sheet flashing with sealing by silicone of approved
make to the structure and fixed with SS 304 hardware. All prices to be inclusive of all Taxes, Statutory RMT 522.00 522.00
requirements, etc.
Certification will be based on actual measurement at site.
Steel Support
c.5 Design,fabricate, deliver (to job site) and install steel structure for precast concrete panels support as per
approved Shop DWGs. Including Epoxy coating, anti rust PU Paint in 3 coats as directed finished complete. MT NA NA
Total
F Operational Manual
f.1 System provided by the contractor has to be approved by the façade consultant . If the system is already tested
in the laboratory, proper testing certificates are required to be submitted and approved by the façade consultant.
If not tested ,the system has to be tested at any certified laboratory (Indian/Overseas)in presence of facade
consultant.
f.2 Test certificates for all accessories like screws, anchor bolts, silicon sealant, EPDM Gaskets etc must be
provided
f.3 Dow Corning representatives has to perform deglazing test on the glazing unit of selected contractor
f.4 Anchor bolt pull out test has to be carried out on site before starting the installation.
f.5 Mock installed by the awarded contractor need to be approved from the facade consultant before carrying out
the installation. The mock up will be a permant mock up based on the grid/reference point.
f.6 PVDF coating has to be tested at the factory of the coaters in presence of façade consultant
f.7 The processing unit of the glass processor will be inspected by the client/ façade consultant before starting the
work
f.8 Contractor shall provide back to back guarantee on all the accessories used in the system
f.9 Additional items may come during later stage based on architect approvals
f.10 Certification will be based on actual measurement at site. All taxes will be inclusive. Any variation has to be
approved by the façade consultant
Testing of Façade
No additional claim will be paid to awarded contractor for laboratory testing and site testing of installed
façade directed by FACET as per AAMA .